1
|
Time-resolved fluoroimmunoassay (TR-FIA) of gonadotropins. EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY 2009; 102:39-43. [PMID: 8005207 DOI: 10.1055/s-0029-1211263] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Time-resolved fluoroimmunoassay (TR-FIA), which has recently been developed as a non-isotopic immunoassay, was intended for assay of gonadotropins (LH and FSH). Ovine LH or FSH was labeled with N1-(p-isothiocyanatobenzyl)-diethylenetriamine-N1, N2, N3, N3-tetraacetic acid Eu-chelate (DTTA), and competitive binding assay was performed using a 96-weel titer plate previously coated with a second antibody, followed by measurement using time-resolved fluorometry. TR-FIA for standard ovine LH (NIDDK, LH-I-3) or FSH (NIDDK, FSH-I-1) had a sensitivity of about 25 pg/50 microliters sample. The assay system was applied to heterologous assay of porcine gonadotropins. Linearity was obtained by the dilution test using medium from primary culture of porcine anterior pituitary cells. Intra- and inter-assay coefficients of variation of LH and FSH determination in 31 different porcine samples were satisfactorily low, between 3.5 and 8.1% (intra-assay) and between 1.7 and 13.1% (inter-assay). Correlation coefficients between radioimmunoassay and TR-FIA were calculated to be 0.945 for LH and 0.978 for FSH. Stimulation of LH and FSH release with GnRH was observed by TR-FIA. This non-isotopic TR-FIA thus provides as good sensitivity, reproducibility and accuracy as conventional RIAs.
Collapse
|
2
|
Performance of a time-resolved fluorescence immunoassay for measuring varicella-zoster virus immunoglobulin G levels in adults and comparison with commercial enzyme immunoassays and Merck glycoprotein enzyme immunoassay. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2006; 13:214-8. [PMID: 16467328 PMCID: PMC1391932 DOI: 10.1128/cvi.13.2.214-218.2006] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.
Collapse
|
3
|
Specific immunofluorimetric assay detecting the chemotactic epitope of the urokinase receptor (uPAR). J Immunol Methods 2005; 308:192-202. [PMID: 16386755 DOI: 10.1016/j.jim.2005.10.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2005] [Revised: 10/31/2005] [Accepted: 10/31/2005] [Indexed: 11/23/2022]
Abstract
The urokinase plasminogen activator receptor (uPAR) fragments D1 and D2D3 are often found in biological fluids from normal individuals and patients of cancer and other diseases. The D2D3 fragment may possess chemotactic activity depending on its N-terminal sequence. We have developed a sensitive and specific immunoassay for the chemotactic form of D2D3 and show that its level can be measured with high specificity and sensitivity in human serum and urine. Synthetic peptides (residues 84-92) derived from the linker region between domains 1 and 2 of uPAR were used as immunogens to generate mouse monoclonal antibodies. Recombinant soluble uPAR (D1D2D3(1-277)) was used to immunize rabbits to obtain polyclonal antibodies. A sandwich-type immunofluorimetric assay was developed with these antibodies. The assay specifically measures D2D3 containing the 84-88 residues, has a detection limit of 0.25 ng/ml and shows no cross-reactivity with D2D3(93-274). The assay is linear at 0-30 ng/ml, with an intra-assay CV of 10% (n=20), inter-assay CV of 15% (n=9) and a recovery of D2D3(84-274) added to urine samples of between 94% and 105%. A statistically significant difference level of D2D3(84-274) was found in two groups of tumor patients versus healthy volunteers (p<or=0.009 in colorectal carcinomas and p<or=0.036 in prostatic carcinomas). For the first time, monoclonal antibodies, detecting the chemotactic form of uPAR, D2D3(84-274), have been produced. The immunofluorimetric assay will quantitate uPAR chemotactic fragments in biological samples, including serum and urine, and evaluate their diagnostic or prognostic potential in clinical studies.
Collapse
|
4
|
Measurement of Vasoactive Intestinal Peptide using a Competitive Fluorescent Microsphere Immunoassay or ELISA in human blood samples. J Immunol Methods 2005; 300:63-73. [PMID: 15894328 DOI: 10.1016/j.jim.2005.02.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2004] [Revised: 02/21/2005] [Accepted: 02/28/2005] [Indexed: 10/25/2022]
Abstract
The concentration of Vasoactive Intestinal Peptide (VIP) as measured by recycling immunoaffinity chromatography (RIC) has been reported to be elevated in the blood of patients with autism as compared with normal subjects. In this study, we have developed a "Competitive Fluorescent Microsphere Immunoassay" (cFMI) in which VIP competes with biotinylated VIP in binding to polyclonal antibodies on microspheres. The results were obtained using the Luminex100 system. We measured VIP in serum, plasma, and material eluted from dried blood spots on filter paper with both the cFMI and an ELISA procedure. We found that a purification procedure was necessary for obtaining useful results from plasma and serum, however, a preincubation step was required with the blood eluates. This newly developed cFMI was more sensitive (2.5 vs. 20.0 pg/ml), and more reproducible than the ELISA. To get accurate measurements of VIP in eluted material high sensitivity is especially important. Thus, the cFMI using the Luminex system has definite advantages over a conventional ELISA including the possibility that samples can be assayed at higher dilutions. We have determined that the VIP concentrations of serum, plasma, and dried blood spot eluate specimens as measured with the cFMI assay system were similar to those measured with ELISA. Thus, the new cFMI using Luminex system may be useful for detection of VIP in human blood samples.
Collapse
|
5
|
Abstract
Metallothioneins (MTs) are a family of low molecular weight metal-binding proteins induced by a broad range of stress conditions, including exposure to transition metal ions. Biochemical and immunological methods to measure MT protein levels in tissues and cultured cells have been reported, but accuracy and sensitivity is impeded by high background levels, low specificity of currently available reagents, and relatively laborious and time-consuming multistep procedures. To address these difficulties, a protocol has been developed to measure MT protein levels using a competitive solid phase assay based on dissociation enhanced lanthanide fluoroimmuno (DELFIA) detection of anti-MT monoclonal antibody bound to solid phase MT. This assay allows time-resolved detection of antibody binding, based on binding and exchange of different lanthanide chelates followed by fluorescent detection, designed to reduce background fluorescence and increase sensitivity. The method allows measurement of low MT levels that are undetectable using current radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) protocols, and yields reproducible results with low background over a wide range of MT concentrations. Improved sensitivity of MT protein detection is of value in toxicological measurement of stress responses and assessment of MT expression and function.
Collapse
|
6
|
Abstract
A fluorescence-based continuous-flow immunosensor for sensitive, precise, accurate and fast determination of paclitaxel was developed. The sensor utilizes anti-paclitaxel antibody immobilized through its Fc region and crosslinked by dimethylpimelimidate to protein A attached covalently onto the silanized inner walls of a glass capillary column followed by saturation of the paclitaxel-binding sites with rhodamine-labeled paclitaxel. The assay is based on the displacement and detection downstream of the rhodamine-labeled paclitaxel, by a flow-through spectrofluorometer, as a result of the competition with paclitaxel introduced as a pulse into the stream of carrier buffer flowing through the system. The peak height of the fluorescence intensity profile of the displaced rhodamine-labeled paclitaxel was directly proportional to the concentration of paclitaxel applied and was a function of the carrier buffer flow rate. The sensitivity of the immunosensor response ranged from 0.31 relative fluorescence units (RFU)/ng/ml at a flow rate 0.1 ml/min to 0.52 RFU/ng/ml at 1 ml/min, while the lower detection limit ranged from 1 ng/ml at 0.1 ml/min to 4 ng/ml at 1 ml/min. The immunosensor response was very reproducible (RSD=4.8%; n=10) and linear up to 100 ng/ml. The assay time ranged from 2 min at 1 ml/min to 8 min at 0.1 ml/min. A technique developed to resaturate the antigen binding sites of the immobilized antibody with rhodamine-labeled paclitaxel was successful in regenerating the capillary column without affecting its performance, thus enhancing the economic viability of the immunosensor. The immunosensor was successfully applied for the determination of paclitaxel in human plasma.
Collapse
|
7
|
Highly sensitive determination of plasma cytokines by time-resolved fluoroimmunoassay; effect of bicycle exercise on plasma level of interleukin-1 alpha (IL-1 alpha), tumor necrosis factor alpha (TNF alpha), and interferon gamma (IFN gamma). ANAL SCI 2001; 17:593-7. [PMID: 11708138 DOI: 10.2116/analsci.17.593] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A highly sensitive time-resolved fluoroimmunoassay of human plasma cytokines is described. The cytokines such as interleukin-1 alpha (IL-1 alpha), tumor necrosis factor alpha (TNF alpha) are known to be acute inflammatory cytokines and it has been reported that these cytokines are secreted into blood by physical exercise. In this study, a sandwich-type immunoassay of cytokines was established using a europium chelate BHHCT-Eu3+ as a powerful labeling material. The minimum detection limits of cytokines, i.e. IL-1 alpha, TNF alpha, and interferon gamma (IFN gamma) were about 1/10 smaller than those of enzyme-linked immunosorbent assay currently used. By this immunoassay we investigated cytokine increase/decrease in plasma which was thought to derive from the myocytes damaged by bicycle exercise. Healthy young men performed two kinds of bicycle ergometer exercises, under conditions of an incremental and a constant loading. Blood samples were taken before, during, and after exercises, and the concentration levels of plasma IL-1 alpha, TNF alpha, and IFN gamma were determined. In the case of incremental exercise, IL-1 alpha increased significantly at the first stage but decreased to the basal level from the second stage, in spite of heavier exercise. In the case of 30 min constant exercise, the level of plasma IFN gamma increased in recovery period, 2 h after the light-exercise. TNF alpha level was significantly higher in a heavy-exercise. The concentration of IL-1 alpha peaked at the early stage of the incremental exercise; this fact has not been reported in previous studies. This cytokine is unique in showing a sudden increase during the early stage, while others increase after the exercise. Our highly sensitive assay made it possible to detect a slight change in plasma cytokines.
Collapse
|
8
|
Highly sensitive and specific time-resolved fluoroimmunoassay (TR-FIA) of cyproterone acetate and free cyproterone. J Steroid Biochem Mol Biol 2000; 75:315-22. [PMID: 11282288 DOI: 10.1016/s0960-0760(00)00189-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We have developed a non-isotopic TR-FIA for Cyproterone acetate and Cyproterone in plasma. Synthesis of the biotinylated tracers, biotinylated Cyproterone acetate, and Cyproterone, as well as the preparation of anti-Cyproterone acetate and anti-Cyproterone antisera are reported. The specificity of anti-Cyproterone acetate antiserum resulting from the coupling of link bridge (link bridge between steroid and BSA), on the 3-position on the steroid skeleton, allowed to carry out the Cyproterone acetate assay directly on extracted plasma (without chromatography). On the other hand Cyproterone assays require a purification step, including extraction plus chromatography, because the plasma Cyproterone acetate concentrations in Cyproterone acetate-treated women are 200 times higher than for Cyproterone. Theses plasma TR-FIA of Cyproterone acetate and Cyproterone presented the advantage of needing only small doses of radioactivity for recovery controls, and better practicability related to the only existing RIA described to date.
Collapse
|
9
|
Abstract
Prostate-specific antigen (PSA) was detected in microtitre wells coated with a PSA-specific antibody using biotinylated antibody and streptavidin-coated, highly fluorescent 107 nm nanoparticles, which contained more than 30000 europium ions entrapped by beta-diketones. PSA was monitored directly on the surface of a well without any additional enhancement step. The sensitivity of the assay was 1.6 ng/L, corresponding to 50 fmol/L or 250 zeptomoles (250 x 10(-21) mol/L) of PSA. The high specific activity and low non-specific binding of the streptavidin-coated nanoparticles improved the sensitivity of the PSA assay 100-fold compared to the conventional europium-labelled streptavidin tracer in the same assay format. Additionally, the streptavidin-coated nanoparticle label made very rapid assays possible, due to the high affinity of the streptavidin-biotin complex and a high number of binding sites available for tracing the biotinylated antibody on the surface. Due to the inherent problems of tracing analyte with a complex of biotinylated antibody and streptavidin-coated nanoparticles, the streptavidin-coated nanoparticles reacting with the surface-captured analyte and biotinylated antibody was favoured and factors influencing this are discussed. This universal labelling technology can be applied to detect any biotinylated molecule, either in solution or on a solid phase, in order to improve detection sensitivities in many areas of biochemical analysis, such as cyto- and histochemistry, multianalyte DNA-chip assays and single-particle assays.
Collapse
|
10
|
Time-resolved fluorometry (TRF)-based immunoassay concept for rapid and quantitative determination of biochemical myocardial infarction markers from whole blood, serum and plasma. LUMINESCENCE 2000; 15:399-407. [PMID: 11114117 DOI: 10.1002/1522-7243(200011/12)15:6<399::aid-bio627>3.0.co;2-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We report the development of a time-resolved fluorometry-based immunoassay concept for the rapid measurement of three cardiac markers from whole blood, serum or plasma. Using a universal all-in-one (AIO) dry reagent concept, all the analyte specific reagents are built into a single microtire well, to which an identical assay protocol is applied. Addition of 5-20 microL sample (whole blood, serum or plasma) together with a universal buffer initiates the reaction, which is brought close to equilibrium in 15 min. After the wash step the Eu chelate-derived signal is measured directly from the dried surface. Application of this concept to the three cardiac markers illustrates its ability to provide rapid, highly sensitive and fully quantitative results over a large dynamic range with good reproducibility. Such a performance, especially when using whole blood specimens, is largely a consequence of the inherently fluorescent and stable Eu-chelate employed in the system. Correlation to commercial assays was excellent for all three analytes, as was between-sample matrix correlation using the AIO assays. The presented assay concept enabling a simple automation is particularly suited for point-of-care applications, where the performance characteristics are fully comparable to state-of-the-art central laboratory immunoassays.
Collapse
|
11
|
Abstract
Avermectins are frequently used to control parasitic infestations in many animal species. Previous studies have shown the long-term persistence of unwanted residues of these drugs in animal tissues and fluids. An immunoassay screening test for the detection and quantification of ivermectin residues in bovine milk has been developed. After an extensive extraction procedure, milk samples were applied to a competitive dissociation-enhanced lanthanide fluoroimmunoassay using a monoclonal antibody against an ivermectin-transferrin conjugate. The monoclonal antibody, raised in Balb C mice, showed cross-reactivity with eprinomectin (92%), abamectin (82%) and doramectin (16%). The limit of detection of the assay (mean + 3 SD), calculated from the analysis of 17 known negative samples, was calculated as 4.6 ng/mL. Intra- and inter-assay RSDs were determined as 11.6% and 15.8%, respectively, using a negative bovine milk sample fortified with 25 ng/mL ivermectin. Six Friesian milking cows were treated with ivermectin, three with a pour-on formulation of the drug and three with an injectable solution at the manufacturer's recommended dose rate. An initial mean peak in ivermectin residue concentration was detected at day 4 (mean level = 47.5 ng/mL) and day 5 post-treatment (mean level = 26.4 ng/mL) with the injectable form and pour-on treatment, respectively. A second peak in residue concentration was observed using the DELFIA procedure 28 days post-treatment in both treatment groups (23.1 ng/mL injectable and 51.9 ng/mL pour-on). These second peaks were not confirmed by HPLC and must at this time be considered to be false-positive results. By day 35 after treatment the mean ivermectin residue concentration of both groups fell below the limit of detection of the assay.
Collapse
|
12
|
A novel and robust homogeneous fluorescence-based assay using nanoparticles for pharmaceutical screening and diagnostics. JOURNAL OF BIOMOLECULAR SCREENING 2000; 5:227-38. [PMID: 10992043 DOI: 10.1177/108705710000500405] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We have established a new type of homogeneous immunoassay based on nanoparticles (nanoparticle immunoassay, or NPIA) being analyzed using fluorescence intensity distribution analysis (FIDA). This method allows the characterization of single fluorescently labeled molecules or particles with respect to their molecular brightness and concentration. Upon binding of conjugates to molecules coupled to the nanoparticle surface, the brightness of the complex scales with the number of bound conjugates. The complexes can then be distinguished accurately from free conjugate and concentrations of free and bound molecules can be determined reliably. In this study we present various examples of NPIAs where capture antibodies were linked to the nanoparticles, which were either artificial beads or bacteria. Two assay formats have been developed; first, direct labeling of the conjugate was used to quantitate free antigen through competition experiments, and second, an antigen-directed antibody was labeled to establish an assay similar to a sandwich ELISA setup. The major advantages of a NPIA are the robustness and high signal-to-noise ratio at short measurement times, as demonstrated with a miniaturized experiment in a Nanocarriertrade mark holding a volume of 1 microl/well. In addition to the good data quality, NPIAs are straightforward to perform because they require no washing steps. NPIAs open new dimensions for high throughput pharmaceutical screening and diagnostics. Assay development times can be reduced significantly because of a simple toolbox principle that is applicable to most types of assays.
Collapse
|
13
|
Development of an offline noncompetitive flow immunoassay for the determination of interleukin-8 in cell samples. Anal Biochem 2000; 279:46-54. [PMID: 10683229 DOI: 10.1006/abio.1999.4442] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A noncompetitive flow immunoassay system (FIA) for the analysis of interleukin-8 (IL-8) in cell samples was developed. Affinity interaction assays based on offline incubation of excess labeled antibodies and antigen (IL-8) were carried out. The residual unbound labeled antibody was trapped in an immunoaffinity column with immobilized IL-8 while the immunocomplex, labeled antibody/IL-8, was detected by a fluorescence detector. Two fluorophores, FLUOS and Cy5.5, were conjugated with IL-8 antibody. Optimization and comparison between the two fluorescent labeled antibodies were performed with regard to pH, antibody concentration, flow rate, injection volume, and association time. Additionally, a horseradish peroxidase enzyme label was used for the conjugation to the anti-IL-8. The enzyme substrate reaction was optimized with respect to temperature and length of the substrate reaction coil. The detection limits were found to be 200 amol using the FLUOS-labeled anti-IL-8 and 1 fmol using the Cy5.5 fluorescence label. The developed FIA technique was applied for the analysis of IL-8 in cell samples. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was used to identify IL-8 in the cell samples.
Collapse
|
14
|
Differences in urinary excretion patterns of the hLH beta core fragment in premenopausal, perimenopausal, and postmenopausal women. Menopause 1999; 6:290-8. [PMID: 10614675 DOI: 10.1097/00042192-199906040-00004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The heterodimeric luteinizing hormone beta core fragment (hLH beta cf) is a highly stable urinary analyte reflective of circulating hLH. It is measured easily because of its high molar content and has none of the multiple isoforms and subunit dissociation problems of LH urinary measurements. As part of a long-term effort to develop new biochemical assays to stage women during the perimenopausal transition, we have examined the patterns of urinary excretion of this metabolite of hLH in premenopausal, perimenopausal, and postmenopausal women. DESIGN We measured the concentration of the hLH beta cf in 10 consecutive first morning void urine specimens from premenopausal, perimenopausal, and postmenopausal women. Day 1 of collection was the first day of menses in the cycling women. RESULTS Postmenopausal women exhibited a widely fluctuating pattern of LH beta core fragment excretion, which is not correlated with hLH measured by immunofluorometric assay or with follicle-stimulating hormone measured by immunofluorometric assay. The postmenopausal group was easily distinguished from premenopausal women on the basis of an area-under-the-curve concentration function. Perimenopausal women displayed intermediate hLH beta cf concentrations; some clearly were in postmenopausal ranges, and others were in the premenopausal ranges. CONCLUSIONS The pattern of excretion and concentrations of the hLH beta cf is significantly different between premenopausal and postmenopausal women. Perimenopausal women exhibited intermediate changes. The capability to measure this type of stable urinary metabolite as a reflection of changes in dynamics of its parent circulating hormone offers new possibilities in the development and application of large-scale testing that does not require blood sampling.
Collapse
|
15
|
Abstract
With T(4)-bovine IgG as a solid-phase antigen, we have developed a direct competitive-type immunoassay for serum total thyroxine (TT(4)), which depends on the competitive distribution of europium-labeled anti-T(4) monoclonal antibody between solid-phase-bound T(4) and the T(4) in the sample or standard. The captured fraction of the tracer was measured after a dissociation-enhancement step. Four different T(4) protein conjugates were synthesized, of which T(4)-bovine IgG was selected as the most favorable for the preparation of solid-phase antigen. The sensitivity was 3.5 ng/ml with a sample volume of 20 microl. T(4) values obtained by this procedure agreed well with those obtained by RIA (r = 0.967, n = 38) and EG&G Wallac TRFIA (r = 0.926, n = 64). All other quality criteria was also fulfilled with respect to precision, accuracy, and dynamic range.
Collapse
|
16
|
Evaluation of single- and dual antigen delayed fluorescence immunoassay in comparison to an ELISA and the in vivo toxin neutralisation test for detection of diphtheria toxin antibodies. J Immunol Methods 1999; 230:131-40. [PMID: 10594360 DOI: 10.1016/s0022-1759(99)00129-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
An evaluation of the delayed fluorescence immunoassay (Delfia) against an ELISA method for determination of diphtheria antitoxin levels in serum was performed. The Delfia was also validated in the in vivo toxin neutralisation test (Txn) in rabbits. Two variants of the Delfia were studied, a single-antigen Delfia (sDelfia) with only the diphtheria toxin included and a dual-antigen Delfia (dDelfia) with tetanus toxoid included for simultaneous detection of antibodies against two antigens. The diphtheria antitoxin cut-off levels in the sDelfia and the dDelfia were 0.004 and 0.002 AU/ml, respectively, which is lower than the internationally accepted level showing any protection against diphtheria (0.01 IU/ml). Both Delfia variants showed good correlation with the ELISA procedure above the ELISA cut-off level of 0.02 AU/ml. Results from samples assayed in the in vivo Txn assay indicated that the low antitoxin levels detected by the Delfia were valid. These results show that the Delfia could be considered as an in vitro reference method for detection of diphtheria antitoxin in seroepidemiological surveys and vaccine studies.
Collapse
|
17
|
[Lanthanide immunofluorescent analysis: virus detection and the serodiagnosis of viral infections]. VESTNIK ROSSIISKOI AKADEMII MEDITSINSKIKH NAUK 1999:26-33. [PMID: 10487120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
Abstract
This communication summarizes 10-year experience gained by the author in developing and using the lanthanide immunofluorescence assay (LIFA) for the laboratory diagnosis of viral infections. The bulk of studies has been conducted on natural focal viruses, including Venezuelan equine encephalitis, tick-borne encephalitis, Crimean Congo hemorrhagic fever, California serogroup, and other viruses. Moreover, test systems have been developed for diagnosis of infections caused by herpes simplex and cytomegaloviruses. The studies performed have demonstrated the sensitivity of LIFA in the indication of viruses in the laboratory materials and the samples from natural foci is 10-100 times higher than that of enzyme immunoassay and it is close to that of the biological isolation assay; the specificity of LIFA is comparable to that of the neutralization reaction, but it is more accessible in practice due to the fact it does not require the use of living viruses and biological models. The results of detection of herpes viruses in the clinical samples by LIFA are shown to rather well correlate with the data of virus isolation in the cultured cells, with other diagnostic methods and with the clinical manifestations of diseases. LIFA is recommended for use in large-scale studies involving the monitoring of infection foci and the screening of risk population groups for social infectious diseases.
Collapse
|
18
|
Development of a magnetic microplate chemifluorimmunoassay for rapid detection of bacteria and toxin in blood. Anal Biochem 1998; 261:1-7. [PMID: 9683505 DOI: 10.1006/abio.1998.2614] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A magnetic microplate chemifluorimmunoassay (MMCIA) is described using an immunomagnetic separation and a fluorescent microplate technique for rapid detection of low-level Escherichia coli O157:H7, Bacillus subtilis var. niger spores, and Staphylococcal enterotoxin type B from whole blood. In general, the MMCIA has at least several-fold more sensitivity than the conventional enzyme-linked immunosorbent assay. In addition, the assay sensitivities using direct fluorochrome label as the reporter, or alkaline phosphatase (AP) with various assay substrates, such as pNPP and AttoPhos, were assessed.
Collapse
|
19
|
A time-resolved fluorescence immunoassay for the measurement of testosterone in saliva: monitoring of testosterone replacement therapy with testosterone buciclate. Clin Chem Lab Med 1998; 36:223-30. [PMID: 9638347 DOI: 10.1515/cclm.1998.038] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Monitoring of testosterone replacement therapy requires a reliable method for testosterone measurement. Determination of salivary testosterone, which reflects the hormone's biologically active plasma fraction, is a superior technique for this purpose. The aim of the present study was to establish a new sensitive time-resolved fluorescence immunoassay for the accurate measurement of testosterone levels in saliva and to validate it by monitoring testosterone replacement therapy in eight hypogonadal men. A clinical phase I-study with the new ester testosterone buciclate was performed to search for new testosterone preparations to produce constant serum levels in the therapy of male hypogonadism. After two control examinations eight male patients with primary hypogonadism were randomly assigned to two treatment groups (n = 2 x 4) and given single doses of either 200 mg (group I) or 600 mg (group II) testosterone buciclate intramuscularly. Saliva and blood samples were obtained 1, 2, 3, 5 and 7 days post injection and then weekly for three months. The time-resolved fluorescence immunoassay for salivary testosterone shows a detection limit of 16 pmol/l, an intra-assay CV of 8.9% (at a testosterone concentration of 302 pmol/l), an inter-assay CV of 8.7% (at a testosterone concentration of 305 pmol/l) and a good correlation with an established radioimmunoassay of r = 0.89. The sample volume required by this method is only 180 microliters for extraction and duplicate determination. The assay procedure requires no more than three hours. In group I (200 mg) testosterone did not increase to normal levels either in saliva or in serum. However, in group II, androgen levels increased significantly and were maintained in the normal range for up to 12 weeks with maximal salivary testosterone levels of 303 +/- 18 pmol/l (mean +/- SE) and maximal testosterone levels of 13.1 +/- 0.9 nmol/l (mean +/- SE) in serum in study week 6 and 7. The time-resolved fluorescence immunoassay for salivary testosterone provides a useful tool for monitoring androgen status in men and women and is well suited for the follow-up of testosterone replacement therapy on an outpatient basis. The long-acting ester testosterone buciclate is a promising agent for substitution therapy of male hypogonadism and in combination with testosterone monitoring in saliva offers an interesting new perspective for male contraception.
Collapse
|
20
|
Abstract
The easily accessible kinetics of a new homogeneous two-site fluorometric immunoassay for prolactin was studied, in order to determine its usefulness for assay data reduction and optimization. The combined use of a simple descriptive model fitted to experimental data and a mechanistic model to simulate the kinetics revealed that (i) the kinetics curve presented an early inflexion point. Its time of occurrence was constant as long as the antigen concentration was below the smallest antibody concentration and decreased to zero for higher concentrations. It may therefore be used as an indicator of hooked samples. (ii) The kinetics steepest slope was correlated with antigen concentration. Its use as a dose-response curve variable would allow higher concentrations to be assayed than with the classical end-point dose-response curve. The results suggest that control and exploitation of kinetic parameters could help to improve the rapidity, analytical range, and reliability of homogeneous two-site immunometric assays.
Collapse
|
21
|
Dual-label time-resolved immunofluorometric assay for simultaneous determination of pregnancy-associated plasma protein A and free beta-subunit of human chorionic gonadotrophin. J Immunol Methods 1997; 205:169-75. [PMID: 9294599 DOI: 10.1016/s0022-1759(97)00073-2] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Using time-resolved fluorometry, a simple one-step dual-label immunometric assay has been developed, which allows simultaneous determination of pregnancy-associated plasma protein A (PAPP-A) and free beta-subunit of human chorionic gonadotrophin (beta-hCG) in first-trimester maternal serum samples. Two monoclonal antibodies were biotinylated and immobilized onto the surface of streptavidin-coated microtitration plates, and used to capture PAPP-A and beta-hCG. respectively. Europium (Eu) and Samarium (Sm) chelates were conjugated to two additional monoclonal antibodies acting as detection antibodies for PAPP-A and beta-hCG. The assay was performed using a 4-h one-step format. The within-run precision with buffer-based calibrators was below 8% over the working range of PAPP-A (40-10000 mIU/l) and beta-hCG (7.3-525 micrograms/l) and no hook effect was observed. The intra- and inter-assay coefficients of variation were below 7.1% for serum samples. PAPP-A and beta-hCG concentrations measured by the dual assay in 39 first-trimester serum samples correlated excellently with those obtained by DELFIA single-label PAPP-A (r = 0.997) and the beta-hCG part (r = 0.993) of the DELFIA AFP/beta hCG dual-label assay.
Collapse
|
22
|
Evaluation of a rapid, quantitative cardiac troponin I immunoassay. EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY : JOURNAL OF THE FORUM OF EUROPEAN CLINICAL CHEMISTRY SOCIETIES 1997; 35:399-404. [PMID: 9189748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
We evaluated a rapid, quantitative immunoassay for the detection of cardiac troponin I. Coefficient of variation is between 1.29 and 13.63% for intra-assay and between 3.88 and 10.15% for inter-assay imprecision. Linearity is given up to 35 micrograms/l. Possible interfering substances (haemoglobin, bilirubin, triacylglycerol and rheuma factors) do not disturb the assay. The analyte is stable under normal storage conditions (+20 degrees C/48 h and +4 degrees C/l week) with decrease up to 30% after 3 months at -20 degrees C. Reference value for apparently healthy individuals is < 0.1 microgram/l. In plasma cardiac troponin I is measured up to 30% depressed compared to serum. Comparison with another cardiac troponin I assay (y = 0.92x + 2.42, r = 0.940) and cardiac troponin T is good with y = 6.61x - 1.94, r = 0.91 for the first generation cardiac troponin T assay and y = 5.59x - 0.68, r = 0.87 for the second generation cardiac troponin T assay. In summary, the evaluated assay is fast, easy to perform, and can be used not only in a specialized laboratory, but is also suitable for emergency laboratory or smaller laboratory units.
Collapse
|
23
|
Analyte and label binding assay read by flow cytometry. Clin Chem 1996; 42:1702-8. [PMID: 8855157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
A new immunometric two-site sandwich assay is introduced, in which a label-scavenging binding partner is added to the sample in addition to the analyte-binding partner. The scavenger binding partner binds excess label antibody, giving a signal proportional to the amount of excess label antibody in the sample solution. A set of two calibration curves is obtained from the two binding partners simultaneously, and a combination of the two signals gives an unambiguous determination of the analyte concentration, even for high analyte concentrations where the hook effect may occur. Two-particle immunofluorometric assays developed for placental alkaline phosphatase and human chorionic gonadotropin on the basis of this principle and yielding signals measured by flow cytometry gave rapid results (2 h) and had working ranges in excess of 5 and 6 orders of magnitude for the respective analytes.
Collapse
|
24
|
One-step all-in-one dry reagent immunoassays with fluorescent europium chelate label and time-resolved fluorometry. Clin Chem 1996; 42:1196-201. [PMID: 8697576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The availability of an intrinsically fluorescent, inert, and stable Eu chelate label made it feasible to design one-step all-in-one immunoassays with time-resolved fluorometry for detection. Both competitive and noncompetitive immunoassays are performed in microtitration wells containing all assay-specific components in a stable dry form. Only the sample and one assay buffer common for all analytes need to be added. Model assays for human chorionic gonadotropin (hCG), alpha-fetoprotein (AFP), and progesterone all reached equilibrium in 15 min or less without compromising the performance characteristics of the measurements, all of which perform at least equivalent to state-of-the-art assays. The detection limits for hCG, AFP, and progesterone were 0.3 IU/L, 0.1 microgram/L, and 0.5 nmol/L, respectively. The assay ranges for hCG and AFP were linear to 5000 IU/L and 1200 micrograms/L, respectively. The immunoassay format can be readily implemented in a fully automated random-access immunoassay system with optimal performance characteristics and no handling of analyte-specific assay components.
Collapse
|
25
|
An amplitude-specific divergence in the pulsatile mode of growth hormone (GH) secretion underlies the gender difference in mean GH concentrations in men and premenopausal women. J Clin Endocrinol Metab 1996; 81:2460-7. [PMID: 8675561 DOI: 10.1210/jcem.81.7.8675561] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Although many studies have discerned higher serum GH concentrations in women than in men, based on measurements of single random blood samples or integrated 24-h means, the neuroendocrine mechanisms that underlie such gender differences have not been defined. Such mechanisms might entail an increase in GH-secretory burst frequency, amplitude, or duration, heightened interpulse basal GH release, or a prolonged half-life of GH. These mechanisms can be distinguished by deconvolution analysis of appropriate GH time series. Earlier studies employed RIA or IRMA with sensitivities of 0.1-0.5 microgram/L, which result in frequently undetectable serum GH concentrations. To address these limitations, we undertook blood sampling at 10-min intervals for 24 h and applied a high-sensitivity immunofluorometric assay of GH (sensitivity 0.0115 microgram/L). Multiparameter deconvolution analysis was used to estimate specific features of GH secretion, while simultaneously calculating the half-life of endogenous GH. Eleven men and 11 premenopausal women from the same community were studied. Discrete peak detection by Cluster was employed as a complementary half-life-independent technique to assign variations in serum GH into pulsatile and basal fractions over 24 h. Cluster revealed significantly higher mean serum GH concentrations over 24 h in women (0.78 +/- 0.08 microgram/L) compared with in men (0.27 +/- 0.03 microgram/L, P < 0.00005). Women exhibited significantly higher maximal serum GH concentration peak values than men (2.08 +/- 0.34 microgram/L in women, 0.67 +/- 0.11 microgram/L in men, P = 0.0008), which could be, in turn, attributed to a significantly increased incremental serum GH peak amplitude (1.85 +/- 0.33 microgram/L in women vs. 0.60 +/- 0.10 microgram/L in men, P = 0.0021) and a longer peak duration (114 +/- 8 min in women, 86 +/- 4 min in men, P = 0.008). The mean area under the serum GH concentration peak was significantly (3-fold) higher in women than in men (98 +/- 17 micrograms/L.min in women, 34 +/- 8 micrograms/L.min in men, P = 0.0046). Serum GH peak frequency was similar in women (9.7 +/- 0.8 peak/24 h) and men (10.7 +/- 1.1 peak/24 h, P = NS). The mechanisms underlying the increase in serum GH concentration pulse amplitude, duration, and area were investigated further by deconvolution analysis. Deconvolution analysis disclosed equivalent secretory pulse frequencies in women and men (13 +/- 0.9 bursts/day in women, 10.5 +/- 1.3 bursts/day in men,P = NS), and statistically indistinguishable mean interburst intervals of 106 +/- 8 min in women and 150 +/- 26 min in men (P = NS). GH-secretory burst mass was significantly higher in women by approximately 2.4-fold (P = 0.0013) compared with in men, which was attributed to a greater burst amplitude. Only low levels of basal GH release were inferred in women (5%) and men (9%), which did not differ significantly between genders. Moreover, the calculated half-life of endogenous GH was no different in women compared with in men: 15.8 +/- 0.7 min vs. 17.1 +/- 0.8 min, respectively (P = NS). The calculated daily secretion rate was 3-fold higher in women (47 +/- 4.8 micrograms/L.24 h) than in men (15 +/- 1.8 micrograms/L.24 h) (P < 0.001). In summary, discrete peak-detection analysis of serum GH concentration profiles collected at 10-min intervals over 24 h in men and premenopausal women discloses significantly different mean serum GH concentrations that are accounted for by higher maximal and incremental serum GH peak amplitudes. Deconvolution analysis demonstrated that the mechanism supporting the amplitude-specific difference in women was an augmentation of the GH-secretory burst mass caused by a higher GH-secretory burst amplitude. These gender differences were highly specific because the frequency of detectable GH-secretory bursts, the calculated endogenous half-life, and the estimated basal GH release were no different in women than in men.
Collapse
|
26
|
Immunofluorometric assay for sensitive and specific measurement of human prostatic glandular kallikrein (hK2) in serum. Clin Chem 1996; 42:1034-41. [PMID: 8674186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Prostate-specific antigen (PSA) and human prostatic glandular kallikrein (hK2) have 79% identity with the primary structure. When we used recombinant hK2 protein, only 7 of 23 monoclonal anti-PSA IgGs (monoclonal antibodies, MAbs) cross-reacted with hK2, which enabled us to design a novel immunofluorometric MAb-MAb assay for the specific detection of hK2. In the first incubation, an excess of MAb 2H11, which does not cross-react with hK2, is added to prevent both free and complexed PSA from reacting in subsequent immunoreactions. In the second incubation, biotinylated MAb H50, which cross-reacts with hK2 by an epitope overlapping with MAb 2H11, served to bind only hK2 to the microtitration wells coated with streptavidin. In the third step, Eu-labeled MAb H117, which cross-reacts with hK2, detected the immobilized hK2. The hK2 assay was calibrated with recombinant hK2. The detection limit of the assay was 0.1 microgram/L, and the cross-reactivity with recombinant PSA was < or = 0.7%. The concentration of hK2 was measured in serum samples from 334 males with total PSA concentrations ranging from 1 to 3400 microgram/L. Most of the samples (57%) had hK2 concentrations below the detection limit. The proportions of hK2 relative to total PSA were 0-2% in 79%, 2-5% in 14%, 5-10% in 4%, and >10% in 3% of the samples. Gel filtration of 10 serum samples with increased hK2 concentrations showed a single peak of hK2 immunoreactivity with an apparent molecular size of approximately 30 kDa, corresponding to that of recombinant hK2 and free PSA.
Collapse
|
27
|
Simultaneous quantitation of diphtheria and tetanus antibodies by double antigen, time-resolved fluorescence immunoassay. J Immunol Methods 1996; 190:171-83. [PMID: 8621952 DOI: 10.1016/0022-1759(95)00270-7] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
A dual, double antigen, time-resolved fluorescence immunoassay (DELFIA) for the simultaneous detection and quantitation of diphtheria (D) and tetanus (T) antibodies in sera has been developed. In the double antigen format one arm of the antibody binds to antigen coated microtitre wells and the other arm binds to labelled antigen to provide a fluorescent signal. This assay was found to be functionally specific for IgG antibodies and showed a good correlation with established toxin neutralization assays. Furthermore, the double antigen set-up was species independent, permitting the direct use of existing international references of animal origin to measure protective antibody levels in humans in international units (IU/ml). The detection limit corresponded to 0.0003 IU/ml with Eu(3+)-labelled toxoids and to 0.0035 IU/ml using Sm(3+)-labelled toxoids. The assay was fast with a high capacity making it a suitable method for serological surveillance studies.
Collapse
|
28
|
Fluorometric and time-resolved immunofluorometric assays for protein-tyrosine phosphatase activity. Clin Biochem 1996; 29:125-31. [PMID: 8601320 DOI: 10.1016/0009-9120(95)02026-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
OBJECTIVE To develop sensitive nonisotopic assays for protein-tyrosine phosphatase (PTP) activity. METHODS The fluorometric assay is based on the fact that phosphotyrosine but not tyrosine forms highly fluorescent complexes with Tb3+. Thus, PTP activity can be followed by measuring the decrease of fluorescence due to hydrolysis of phosphotyrosine. The time-resolved immunofluorometric assay employs tyrosine-phosphorylated substrates, immobilized on microtitre wells. After incubation with PTP, the remaining phosphotyrosine residues are reacted with an antiphosphotyrosine antibody. The immunocomplexes formed are detected with an alkaline phosphatase (ALP)-labeled second antibody. The phosphate ester of 5' fluorosalicylate (FSAP) is used as substrate. The fluorosalicylate produced forms highly fluorescent complexes with Tb3+ - EDTA in alkaline solution. The fluorescence is measured with a time-resolved fluorometer. RESULTS The truncated form of the T-cell protein tyrosine phosphatase (TCdeltaC11 PTP) was determined in the range 1100-36,500 U/L by the fluorometric assay and 36-7100 U/L by the time-resolved immunofluorometric assay. CONCLUSIONS The two nonisotopic assays should prove beneficial for the determination and study of various PTP.
Collapse
|
29
|
Development of sensitive immunoassays to detect amylin and amylin-like peptides in unextracted plasma. Clin Chem 1996; 42:576-85. [PMID: 8605675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Amylin is a 37-amino-acid polypeptide synthesized in and secreted from pancreatic beta cells along with insulin. Its biological actions include the slowing and reduction of postmeal increases in plasma glucose concentrations. Studies of the basic amylin biology in humans have been hampered by the lack of a rapid, sensitive assay capable of measuring physiological concentrations of amylin in small volumes of plasma. We report here two sandwich-type immunoassays that use pairs of monoclonal antibodies, the fluorescent substrate 4-methylumbelliferyl phosphate, and the enzyme alkaline phosphatase. The minimum detectable concentration of amylin in 50 microL of plasma was 0.5 to 2 pmol/L, and the dynamic range was 2 to 100 pmol/L. The assays had average intraassay CVs of <10%, average interassay CVs of <15%, and good linearity on dilution and recovery of added amylin. The two assays use the same detection antibody, which binds to the carboxyl terminus of the molecule, but different capture antibodies. One of the assays measures only human amylin; the other also detects amylin-like peptides. Examples of measurements in human plasma are provided in subjects with impaired glucose tolerance and in nondiabetic controls.
Collapse
|
30
|
Abstract
A dual channel, evanescent fluoroimmunoassay format is used to detect femtomolar analyte concentrations (i.e. less than 1 part per trillion [w/w]) on an etched channel siliconoxynitride thin film integrated optical waveguide. Two assays are used to demonstrate the dose-response behaviour of the sensor: (1) a direct assay of a fluorescently-labeled protein ligand binding to an immobilized protein receptor, and (2) an indirect sandwich assay of a non-fluorescent protein ligand binding to an immobilized protein receptor, as detected by the binding of a fluorescently-labeled secondary receptor protein. A red-emitting cyanine dye (Cy-5), which minimized background fluorescence and scatter losses of the waveguide, was used in both assays. To our knowledge, this is the first report of femtomolar sensitivity in an immunosensing instrument.
Collapse
|
31
|
Abstract
A novel non-competitive idiometric time-resolved fluoroimmunoassay for the determination of serum progesterone was developed, based on the use of two types of anti-idiotypic antibody that recognize different epitopes within the hypervariable region of the primary antiprogesterone antibody. The first anti-idiotype, the betatype, competes with progesterone for an epitope of the primary antiprogesterone antibody at the binding site. The second anti-idiotype, the alphatype, binds to the antiprogesterone antibody in the presence of progesterone, but does not bind to the betatype antiprogesterone complex due to epitope proximity. In the present configuration, the biotinylated alphatype was captured onto anti-biotin IgG which was immobilized on microtiter wells. Reaction mixtures containing europium-labeled antiprogesterone antibody complexed sequentially with progesterone in standards or serum samples and with the betatype anti-idiotypic antibody were then reacted with the immobilized alphatype anti-idiotypic antibody. After 30 min of incubation, the fluorescence of europium is measured by time-resolved fluorescence and is proportional to the concentration of progesterone over the range 0-320 nmol/mL. The method demonstrates good sensitivity, precision, and comparability with a direct competitive radioimmunoassay. The idiometric assay for progesterone is suitable for dipstick technology and biosensors.
Collapse
|
32
|
Generation and characterization of monoclonal antibodies to human type-5 tartrate-resistant acid phosphatase: development of a specific immunoassay of the isoenzyme in serum. Clin Chem 1995; 41:1495-9. [PMID: 7586523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
We have characterized four monoclonal antibodies (mAbs) to the purple ("tartrate-resistant," band 5) acid phosphatase of the human osteoclast (TRAP) and used these to develop a specific serum immunoassay. All four mAbs are of high affinity (Ka = 1-5 x 10(8) L/mol) with a very fast Kassoc (0.2-2.0 x 10(5) L mol-1 s-1) and a moderate Kdissoc (1-3 x 10(-3) s). Two of the mAbs were selected to develop a time-resolved fluorescence immunoassay to measure serum concentrations of TRAP. The mean serum immunoreactive TRAP in a group of healthy premenopausal women and men was 3.7 +/- 1.8 micrograms/L (mean +/- SD) and 3.5 +/- 1.6 micrograms/L, respectively. Significantly higher concentrations of TRAP were found in postmenopausal women (6.3 +/- 2.3 micrograms/L) and in eight patients with Gaucher disease (19.3 +/- 4.7 micrograms/L). Further studies are required to investigate the value of serum TRAP as a marker of bone resorption.
Collapse
|
33
|
Free and complexed prostate-specific antigen (PSA): in vitro stability, epitope map, and development of immunofluorometric assays for specific and sensitive detection of free PSA and PSA-alpha 1-antichymotrypsin complex. Clin Chem 1995; 41:1480-8. [PMID: 7586521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Generation of 15 monoclonal antibodies (MAbs) allowed construction of epitope maps and specific two-site immunofluorometric assays for free prostate-specific antigen (PSA) and PSA complexed with alpha 1-antichymotrypsin (ACT). Close correlation of PSA concentrations obtained with the use of different assays of free PSA suggested extensive similarity in immunodetection of free PSA in serum. Assays of the PSA-ACT complex overestimated the concentration of PSA-ACT in serum because of nonspecific adsorbance of ACT or cathepsin G-complexed ACT to the solid phase. This interference was substantially decreased in the presence of heparin. In studying the stability of purified PSA and PSA-ACT complexes formed in vitro, we found that the free PSA was stable during storage for 4 weeks at 35 degrees C, whereas PSA-ACT complexes largely dissociated in these conditions. The instability of PSA-ACT complexes was counteracted by storage at low temperatures, by adjusting the pH of the storage buffer between 6.8 and 7.4, and through addition of 100-1000-fold molar excess of native ACT. The ease of calibration and the accuracy of free PSA assays in comparison with assays of the PSA-ACT complex suggest that measurements of free to total PSA most accurately reflect the inverse of the proportion of PSA complexed to ACT in serum.
Collapse
|
34
|
Two sensitive time-resolved fluoroimmunoassays for cellular fibronectin. Clin Chem 1995; 41:1283-7. [PMID: 7656438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Two sensitive sandwich-type immunoassays for determination of cellular fibronectin (cFN) in cell culture supernatants and in human plasma were developed. Both assays used a monoclonal antibody with specificity against the EDA sequence, which is characteristic for the cellular form of human and rat FN. Assay 1 involves binding of FN on gelatin-coated microwells followed by reaction with the anti-cFN antibody, whereas in assay 2 the anti-cFN antibody was immobilized first and detection was with an anti-FN antiserum. Time-resolved fluorescence spectrophotometry with measurement of an Eu3+ chelator after dissociation of the solid-phase complexes with urea/sodium dodecyl sulfate in the presence of excess Eu3+ was the detection method. The detection limit of the new assays was between 2.6 and 4.0 micrograms/L cFN. In serial dilution of human plasma samples, parallelism with the calibration curve was obtained over the whole measuring range (12-1000 micrograms/L) with assay 2, whereas assay 1 had deviations of the dilution curves at concentrations > or = 100 micrograms/L. The between-run CVs for assays 1 and 2 were 11.4% and 7.2%, respectively, at a concentration of 200 micrograms/L (median value of 18 experiments). Respective within-series CVs of 4.3% and 4.7% were obtained at the same concentration. The recovery of added cFN from human plasma was between 90% and 96%.
Collapse
|
35
|
Abstract
A time-resolved fluoroimmunoassay (TR-FIA) for the direct determination of clenbuterol residues in horse urine using a highly specific monoclonal antibody has been compared with an immunoenzymometric assay (IEMA). The sensitivity of both methods was 10 pg; the calibration curve was linear between 10 and 10(5) pg for the TR-FIA and between 10 and 10(4) pg for the IEMA.
Collapse
|
36
|
Time-resolved immunofluorometric assay for quantifying proinsulin in serum. Clin Chem 1995; 41:942-3. [PMID: 7768017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
37
|
Neuron-specific enolase (NSE) in serum. Comparison of monoclonal versus polyclonal assay based on 392 blood samples. Int J Biol Markers 1995; 10:1-4. [PMID: 7629420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Neuron-specific enolase (NSE) is the best described serum tumor marker for small cell lung cancer (SCLC). Almost all clinical studies carried out so far used assays involving polyclonal antibodies against NSE; the majority of the studies analyzed the samples by a RIA NSE kit. We evaluated a new monoclonal kit and compared it to the polyclonal kit. We analyzed 392 serum samples, 265 from patients with SCLC, 88 from non-small cell lung cancers (NSCLC) and 39 from children with neuroblastomas. We found a good correlation between the results of the two assays. When correlating NSE in SCLC as measured with the two assays with clinical data, we found the same sensitivity, prognostic impact and value in treatment monitoring. We conclude that the "new" monoclonal assay is a fully acceptable alternative to the "old" polyclonal assay.
Collapse
|
38
|
Lipoprotein(a) in cerebrospinal fluid measured by highly sensitive time-resolved immunofluorometric assay. Clin Chem 1994; 40:1975-6. [PMID: 7923782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
39
|
A clinically useful method for detecting gonadotropins in children: assessment of luteinizing hormone and follicle-stimulating hormone from urine as an alternative to serum by ultrasensitive time-resolved immunofluorometric assays. Pediatr Res 1994; 36:221-6. [PMID: 7970938 DOI: 10.1203/00006450-199408000-00014] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
To study the feasibility of noninvasive sampling in pediatric patients, we examined the concentrations of LH and FSH in paired serum and urine samples from 65 children (age 0-15 y) with highly sensitive time-resolved immunofluorometric assays. The detection limits of the assays were 0.015 IU/L for LH and 0.018 IU/L for FSH. These sensitivity levels allowed quantification of the low prepubertal LH and FSH concentrations. The correlation between serum and urine gonadotropin values was very good (r = 0.751, p < 0.001 for FSH; and r = 0.720, p < 0.001 for LH), and the urine and serum concentrations were very similar. Correction of urinary gonadotropin concentrations for changes in urinary flow by standard methods using density [concentration x (0.02/density-1)] or creatinine (concentration/creatinine) did not improve the correlation. Therefore, measurement of urinary gonadotropins without correction can simply be used in the pediatric outpatient setting as a noninvasive alternative to serum determinations.
Collapse
|
40
|
Measurement of gonadotropins in dried blood spots. Clin Chem 1994; 40:448-53. [PMID: 8131281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
We describe direct immunofluorometric assays for luteinizing hormone (hLH) and follicle-stimulating hormone (hFSH) in fingerstick blood spots dried on filter paper, based on modifications of commercially available kits. Determinations are made from 2.5-mm-diameter discs (3 microL of dried blood) punched out from blood spot standards and samples. Sample dose detection limits of the assays (IU/L) are 0.26 for LH and 0.13 for FSH, with mean interassay CVs of 11.6% (LH) and 7.8% (FSH) at low concentrations. Analytical recoveries of added hormone averaged 100% for LH and 95% for FSH. Clinical studies showed that values for blood spots (x) and directly assayed plasma (y) are highly correlated, so that results from blood spots can be converted directly to plasma equivalents, as follows: yLH = 0.07 + 1.90 xLH, and yFSH = 0.424 + 2.207 xFSH. These gonadotropins are stable in blood spots for at least a year under refrigeration; LH for at least 8 weeks and FSH 6 weeks at 22 degrees C; and both hormones for a week at 37 degrees C. These methods thus allow self-sampling, serial sampling, and mailing of specimens.
Collapse
|
41
|
Demonstration and minimization of serum interference in flow cytometric two-site immunoassays. Clin Chem 1994; 40:420-5. [PMID: 7510591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
The ability of serum factors to cross-link labeled mouse monoclonal antibody (mAb) of irrelevant specificity (mAb FN61, subclass IgG1) to different particle types coated with sheep IgG, bovine gamma-globulin, or mAb FN61 was measured simultaneously by flow cytometry. Significant interference with mAb FN61-coated particles was detected in 53 of 101 sera. Of the 30 sera showing the most pronounced interference, 23 were characterized by an even stronger cross-linking to particles coated with bovine gamma-globulin. These were designated type 1 sera. Seven sera, designated type 2, displayed a dominant interference with the mAb FN61-coated particles. The interference reaction in the two serum types was characterized by different kinetics, dependence on particle concentration, and response to blocking agents. The interference was minimized by addition of 500 micrograms of bovine gamma-globulin and 50 micrograms of mAb HH1 (IgG1) of irrelevant specificity per 10 microL of serum sample in a final assay volume of 100 microL.
Collapse
|
42
|
Ability of two new thyrotropin (TSH) assays to separate hyperthyroid patients from euthyroid patients with low TSH. Clin Chem 1994; 40:101-5. [PMID: 8287514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
We evaluated the ability of new thyrotropin (TSH) assays to separate hyperthyroid (n = 50) patients from clinically euthyroid subjects with low TSH values (nodular goiter, n = 20, and nonthyroidal illness, n = 22). Only patients whose serum TSH was < 0.1 mIU/L by immunoradiometric assay were included. We used a new immunofluorometric method based on time-resolved fluorescence (TR-IFMA) and a new immunochemiluminometric assay (ICMA) to measure TSH in serum. Although the differences between the hyperthyroid patients and the euthyroid patients differed from each other by both methods (P = 0.0012 for TR-IFMA and P < 0.0001 for ICMA), there was no cutoff point that could definitely separate the groups. Thus, it is not possible to draw any definite conclusions on whether a patient is hyperthyroid or not, solely on the basis of TSH concentration measured with these new TSH assays.
Collapse
|
43
|
Time-resolved immunofluorometric assay of total renin in plasma and follicular fluid. Clin Chem 1994; 40:74-9. [PMID: 8287548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
We developed a new time-resolved immunofluorometric assay (TR-IFMA) using two monoclonal antibodies for the total renin measurement in human plasma and follicular fluid. No conversion of prorenin to renin was needed because the assay detected both renin and prorenin. The detection limit of the assay was 10 ng/L and the linear range was 10-25,000 ng/L. Within-assay precision (CV) was 15-8% at renin concentrations of 50-12,200 ng/L. Between-assay precision was 19-3% at concentrations of 100-18,000 ng/L. Analytical recovery of added renin was 85-104% (n = 5) in plasma samples and 104-119% (n = 3) in follicular fluids. For plasma, the reference interval was 78-262 ng/L in men (n = 44) and 36-226 ng/L in women (n = 43).
Collapse
|
44
|
Simultaneous assay of alpha-fetoprotein and free beta subunit of human chorionic gonadotropin by dual-label time-resolved immunofluorometric assay. Clin Chem 1993; 39:2084-9. [PMID: 7691439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
We developed a simple, rapid two-step dual-label assay for the noncompetitive determination of alpha-fetoprotein (AFP) and beta subunit of human chorionic gonadotropin (hCG beta) in serum. Monoclonal antibodies to detect AFP and hCG beta were labeled with europium (Eu) and samarium (Sm), respectively. Highly fluorescent chelates were developed by using the Delfia enhancement principle. The detection limits for AFP and hCG beta were approximately 0.02 kIU/L and approximately 0.2 IU/L, respectively. The within-run precision was < 5% over the whole range of AFP (1-500 kIU/L) and hCG beta (1-200 IU/L) concentrations tested. Cross-reaction of intact hCG was < 0.03%. The AFP concentrations determined with the dual-label assay correlated well with those obtained by Delfia AFP single-label kit. The concentrations of hCG beta were in good agreement with recently published data. Storing the serum samples for 24 h or 1 week at room temperature increased the hCG beta concentration by 4% and 26%, respectively. At 35 degrees C this dissociation of hCG increased 30-40-fold. Repeated freezing and thawing had no effect on the hCG beta concentration.
Collapse
|
45
|
Ultrasensitive time-resolved immunofluorometric assay of prostate-specific antigen in serum and preliminary clinical studies. Clin Chem 1993; 39:2108-14. [PMID: 7691442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
We developed an ultrasensitive method for measuring prostate-specific antigen (PSA) in serum. The assay includes a capture monoclonal anti-PSA antibody coated to microtiter wells, a biotinylated rabbit polyclonal detection antibody, and alkaline phosphatase (ALP)-labeled streptavidin. The activity of ALP is measured with the substrate diflunisal phosphate; the released diflunisal forms highly fluorescent complexes with Tb(3+)-EDTA that are quantified with microsecond time-resolved fluorometry. The assay is precise and accurate and correlates well with the established Hybritech Tandem-PSA kit. Its distinguishing feature is extreme sensitivity (lowest limit of detection is 0.002 micrograms/L or 2 x 10(6) PSA molecules per assay). This is the most sensitive PSA assay reported thus far; we used it to quantify PSA in patients who had undergone radical prostatectomy. Many patients had < 0.01 micrograms/L PSA in their serum. This method could have important clinical applications in postsurgical early detection of relapse or residual prostate cancer, as recently suggested in the literature (Clin Chem 1992;38:1930-2).
Collapse
|
46
|
Homogeneous immunofluorometric assays of alpha-fetoprotein with macroporous, monosized particles and flow cytometry. Clin Chem 1993; 39:2174-81. [PMID: 7691444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
We evaluated two homogeneous immunofluorometric assays (IFMAs) of alpha-fetoprotein (AFP) based on new macroporous acrylate particles combined with flow cytometry. The standard IFMA, requiring 1 h of incubation, provided a working range from 1.8 to > 900 kIU/L (CV < 10%) and a detection limit of 0.6 kIU/L. Use of overnight incubation and a lower particle concentration extended the working range by 1 decade in the lower end. Analytical recoveries for the standard IFMA varied between 97% and 108%. The slope and y-intercept of the regression line correlating measurements by the standard IFMA and a routine immunoradiometric assay were not significantly different from 1 and 0, respectively (P > 0.5), and the correlation coefficient was 0.996. High precision and warning of spuriously high measurements were obtained by including in each sample separate particle types for detecting instrument instability and measuring nonspecific binding only.
Collapse
|
47
|
Double-label time-resolved immunofluorometric assay of prostate-specific antigen and of its complex with alpha 1-antichymotrypsin. Clin Chem 1993; 39:2098-103. [PMID: 7691441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
We have developed a procedure for simultaneous immunofluorometric assay (IFMA) of prostate-specific antigen (PSA) and its complex with alpha 1-antichymotrypsin (ACT). A PSA-specific monoclonal antibody, which captures both free PSA and the PSA-ACT complex, was used as solid-phase antibody. Total PSA immunoreactivity was measured with a Eu(3+)-labeled PSA antibody that reacted with both free PSA and PSA-ACT. PSA-ACT was assayed simultaneously with a Sm(3+)-labeled polyclonal ACT antibody as a tracer. As standard we used pooled serum in which most of the PSA occurred as the PSA-ACT complex. The assay range was 0.03-500 micrograms/L for total PSA and 0.16-450 micrograms/L for PSA-ACT. In comparison with the assay for total PSA, assay of the PSA-ACT/PSA ratio improved the clinical specificity for cancer by reducing the number of false-positive results in prostatic hyperplasia.
Collapse
|
48
|
Competitive time-resolved immunofluorometric assay for quantifying carbonic anhydrase VI in saliva. Clin Chem 1993; 39:2154-7. [PMID: 8403401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A competitive time-resolved immunofluorometric assay sensitive and robust enough for quantifying human salivary carbonic anhydrase isoenzyme VI (HCA VI) was developed. The solid-phase immunoassay is based on competition between Eu(3+)-labeled HCA VI and salivary HCA VI for polyclonal rabbit anti-HCA VI antibodies that are attached to microtiter plate wells precoated with sheep anti-rabbit IgG. The subsequent immunoassay including the separation of free and bound HCA VI requires only one incubation step, after which the Eu3+ of the bound labeled antigen is released into an enhancement solution. The highly fluorescent Eu chelates formed in this solution are then quantified by time-resolved fluorometry (Delfia). The time-resolution principle effectively obviates possible interferences from complex biological material such as saliva. The assay detection limit was 1.5 micrograms/L. Intra- and interassay imprecisions (CVs) were 5.1% and 5.3%, respectively. The mean analytical recovery was 93%. The mean +/- SD concentration of HCA VI in paraffin-stimulated saliva was 6.8 +/- 4.3 mg/L (n = 30) and the secretion rate was 10.2 +/- 7.9 micrograms/min. The method was useful for further investigations of the role of HCA VI in difficult matrices, e.g., saliva.
Collapse
|
49
|
Time-resolved immunofluorometric assay of human growth hormone. Clin Chem 1993; 39:1620-5. [PMID: 8353947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
We describe a time-resolved immunofluorometric assay (trIFMA) for human growth hormone (hGH), in which monoclonal antibody (mAb)-coated microtiter strip wells and a europium (Eu) chelate-labeled mAb are used. We compare the new trIFMA, in which two mAbs are used, with an immunoradiometric assay (IRMA) in which polyclonal antibodies are used. Serum samples (n = 185) from 36 children with various diagnoses were analyzed. In addition, 24-h profile samples (72 per child) from 39 children were analyzed. The trIFMA was more sensitive (detection limit, 0.03 mIU/L) than existing IRMAs. Both the intra- and interassay CVs were < or = 10.6% for hGH concentrations between 1 and 100 mIU/L. The trIFMA is technically simple and rapid, requires no centrifugation or separation reagent, and has a counting time of only 1 s per sample. In addition, the Eu label is nontoxic, presents no waste-disposal problems, and has a long shelf-life. Finally, the assay requires only small volumes of serum (25 muL), which is of considerable importance in pediatric use. The mAbs used for the trIFMA selectively bind the 22-kDa form of hGH, with the result that the assay detects about 80% of the amount detected by the polyclonal IRMA.
Collapse
|
50
|
Space-resolved fluoroimmunoassay for quantifying alpha-fetoprotein in serum. Clin Chem 1993; 39:1659-61. [PMID: 7689045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
A nickel-coated surface was used to adsorb a monolayer of anti-human alpha-fetoprotein antibody. After incubation with a patient's serum, the sample was stained with fluorescein isothiocyanate (FITC)-conjugated anti-human alpha-fetoprotein antibody. These slides were then read with a space-resolved fluorometer to determine the amount of FITC adsorbed onto the metal surface. We used an argon laser as the light source in the fluorometer. The parallel laser beam was tilted at about 45 degrees to the sample surface. The fluorescence from FITC was read with a perpendicular photon counter to reduce noise. The CV for these tests was approximately 10%. Comparison of these results (y) with those of a conventional radioimmunoassay (x) produced the regression equation y = 0.99x + 0.5, over the range 10-140 micrograms/L (n = 51).
Collapse
|