1
|
Choudhary P, Mohanty S, Nayak SK, Unnikrishnan L. Poly(L-lactide)/polypropylene blends: Evaluation of mechanical, thermal, and morphological characteristics. J Appl Polym Sci 2011. [DOI: 10.1002/app.33866] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
|
14 |
83 |
2
|
Kumar A, Choudhary P, Kumar A, Camargo PHC, Krishnan V. Recent Advances in Plasmonic Photocatalysis Based on TiO 2 and Noble Metal Nanoparticles for Energy Conversion, Environmental Remediation, and Organic Synthesis. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2101638. [PMID: 34396695 DOI: 10.1002/smll.202101638] [Citation(s) in RCA: 79] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/06/2021] [Indexed: 05/24/2023]
Abstract
Plasmonic photocatalysis has emerged as a prominent and growing field. It enables the efficient use of sunlight as an abundant and renewable energy source to drive a myriad of chemical reactions. For instance, plasmonic photocatalysis in materials comprising TiO2 and plasmonic nanoparticles (NPs) enables effective charge carrier separation and the tuning of optical response to longer wavelength regions (visible and near infrared). In fact, TiO2 -based materials and plasmonic effects are at the forefront of heterogeneous photocatalysis, having applications in energy conversion, production of liquid fuels, wastewater treatment, nitrogen fixation, and organic synthesis. This review aims to comprehensively summarize the fundamentals and to provide the guidelines for future work in the field of TiO2 -based plasmonic photocatalysis comprising the above-mentioned applications. The concepts and state-of-the-art description of important parameters including the formation of Schottky junctions, hot electron generation and transfer, near field electromagnetic enhancement, plasmon resonance energy transfer, scattering, and photothermal heating effects have been covered in this review. Synthetic approaches and the effect of various physicochemical parameters in plasmon-mediated TiO2 -based materials on performances are discussed. It is envisioned that this review may inspire and provide insights into the rational development of the next generation of TiO2 -based plasmonic photocatalysts with target performances and enhanced selectivities.
Collapse
|
Review |
3 |
79 |
3
|
Choudhary P, Canniffe C, Jackson DJ, Tanous D, Walsh K, Celermajer DS. Late outcomes in adults with coarctation of the aorta. Heart 2015; 101:1190-5. [PMID: 25810155 DOI: 10.1136/heartjnl-2014-307035] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2014] [Accepted: 02/25/2015] [Indexed: 12/15/2022] Open
Abstract
AIMS Previous cohort studies of patients with coarctation of the aorta (CoA) demonstrate reduced long-term survival. Improved surgical outcomes in children and evolution of adult congenital heart disease (ACHD) services have resulted in improved survival in patients with other CHDs. We hypothesise that for young adult patients with CoA long-term outcomes have improved in the contemporary era. METHODS 151 patients (58% men) with simple CoA followed up at a tertiary ACHD service in Sydney, Australia, from 1993 to 2013 were included. We documented mortality and major morbidity such as the need for re-intervention for re-coarctation or aneurysms. RESULTS 140 patients (mean age 35±15 years) underwent CoA repair at median age of 5 (IQR 0-10) years. Initial surgical strategy included end-to-end repair in 43, subclavian flap aortoplasty in 28 and patch aortoplasty in 31 patients (and was not documented in 28 cases). 6 patients had endovascular repair, 4 had interposition tube grafts and 11 were unrepaired. There were a total of seven deaths at a median age of 60 years. Actuarial survival was 98% at 40, 98% at 50 and 89% at 60 years of age. Re-coarctation occurred in 34% and descending aortic aneurysms were noted in 18%. Patients with end-to-end repair had lower rates of significant re-coarctation or descending aortic aneurysms (p=0.026 and <0.001, respectively). 66% had bicuspid aortic valve and 44% were hypertensive. CONCLUSIONS Patients with CoA who reach adolescence demonstrate very good long-term survival up to age 60 years. Long-term morbidity is common, however, related largely to aortic complications and late hypertension.
Collapse
|
Research Support, Non-U.S. Gov't |
10 |
78 |
4
|
Thompson N, Choudhary P, Hughes RA, Quinlivan RM. A novel trial design to study the effect of intravenous immunoglobulin in chronic inflammatory demyelinating polyradiculoneuropathy. J Neurol 1996; 243:280-5. [PMID: 8936360 DOI: 10.1007/bf00868527] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Using a novel trial design, we prospectively examined the effect of intravenous immunoglobulin in seven patients with chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) in a double-blind, placebo-controlled cross-over study. We suggest that the commonly used manual muscle testing and Rankin scale are not sufficiently sensitive to measure changes in CIDP and should not be used as isolated outcome measures. We propose a timed 10-m walk, the Nine-Hole Peg Test, the Hammersmith Motor Ability Score, and myometry as alternative measures which are valid, reliable and sensitive. Our trial design permitted the measurement of a treatment response in three responders despite different patterns of disability typical of the broad clinical picture seen in CIDP.
Collapse
|
Clinical Trial |
29 |
69 |
5
|
Slattery D, Amiel SA, Choudhary P. Optimal prandial timing of bolus insulin in diabetes management: a review. Diabet Med 2018; 35:306-316. [PMID: 29044708 PMCID: PMC5836969 DOI: 10.1111/dme.13525] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/12/2017] [Indexed: 12/12/2022]
Abstract
The inability to achieve optimal diabetes glucose control in people with diabetes is multifactorial, but one contributor may be inadequate control of postprandial glucose. In patients treated with multiple daily injections of insulin, both the dose and timing of meal-related rapid-acting insulin are key factors in this. There are conflicting opinions and evidence on the optimal time to administer mealtime insulin. We performed a comprehensive literature search to review the published data, focusing on the use of rapid-acting insulin analogues in patients with Type 1 diabetes. Pharmacokinetic and pharmacodynamic studies of rapid-acting insulin analogues, together with postprandial glucose excursion data, suggest that administering these 15-20 min before food would provide optimal postprandial glucose control. Data from clinical studies involving people with Type 1 diabetes receiving structured meals and rapid-acting insulin analogues support this, showing a reduction in post-meal glucose levels of ~30% and less hypoglycaemia when meal insulin was taken 15-20 min before a meal compared with immediately before the meal. Importantly, there was also a greater risk of postprandial hypoglycaemia when patients took rapid-acting analogues after eating compared with before eating.
Collapse
|
Systematic Review |
7 |
63 |
6
|
Choudhary P, Geddes J, Freeman JV, Emery CJ, Heller SR, Frier BM. Frequency of biochemical hypoglycaemia in adults with Type 1 diabetes with and without impaired awareness of hypoglycaemia: no identifiable differences using continuous glucose monitoring. Diabet Med 2010; 27:666-72. [PMID: 20546285 DOI: 10.1111/j.1464-5491.2010.03006.x] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE Impaired awareness of hypoglycaemia (IAH) is a major risk factor for severe hypoglycaemia in Type 1 diabetes. Although biochemical hypoglycaemia is asserted to be more frequent in IAH, this has not been estimated accurately. The aim of this study was to use Continuous Glucose Monitoring (CGM) to quantify hypoglycaemia in IAH and evaluate its use in identifying impaired awareness of hypoglycaemia. METHODS Ninety-five patients with Type 1 diabetes were classified as having normal (n = 74) or impaired awareness (n = 21) using an established method of assessing hypoglycaemia awareness. Hypoglycaemia exposure was assessed prospectively over 9-12 months using weekly 4-point capillary home blood glucose monitoring (HBGM), 5 days of CGM and prospective reporting of severe hypoglycaemia. The frequencies of biochemical and severe hypoglycaemia were compared in patients with normal and impaired awareness of hypoglycaemia. RESULTS Patients with impaired awareness had a 3-fold higher incidence of severe hypoglycaemia than those with normal awareness [incidence rate ratio (IRR) 3.37 (95% CI 1.30-8.7); P = 0.01] and 1.6-fold higher incidence of hypoglycaemia on weekly HBGM [IRR 1.63 (95% CI 1.09-2.44); P = 0.02]. No significant differences were observed with CGM [IRR for sensor glucose < or = 3.0 mmol/l 1.47 (95% CI 0.91-2.39); P = 0.12; IRR for sensor glucose < or = 2.2 mmol/l 1.23 (95% CI 0.76-1.98); P = 0.40]. CONCLUSIONS Patients with Type 1 diabetes with impaired awareness had a 3-fold higher risk of severe hypoglycaemia and 1.6-fold higher incidence of biochemical hypoglycaemia measured with weekly glucose monitoring compared with normal awareness, but 5 days of CGM did not differentiate those with impaired from those with normal awareness.
Collapse
|
|
15 |
55 |
7
|
Brooks AM, Walker N, Aldibbiat A, Hughes S, Jones G, de Havilland J, Choudhary P, Huang GC, Parrott N, McGowan NWA, Casey J, Mumford L, Barker P, Burling K, Hovorka R, Walker M, Smith RM, Forbes S, Rutter MK, Amiel S, Rosenthal MJ, Johnson P, Shaw JAM. Attainment of metabolic goals in the integrated UK islet transplant program with locally isolated and transported preparations. Am J Transplant 2013; 13:3236-43. [PMID: 24119216 DOI: 10.1111/ajt.12469] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2013] [Revised: 08/02/2013] [Accepted: 08/10/2013] [Indexed: 01/25/2023]
Abstract
The objective was to determine whether metabolic goals have been achieved with locally isolated and transported preparations over the first 3 years of the UK's nationally funded integrated islet transplant program. Twenty islet recipients with C-peptide negative type 1 diabetes and recurrent severe hypoglycemia consented to the study, including standardized meal tolerance tests. Participants received a total of 35 infusions (seven recipients: single graft; 11 recipients: two grafts: two recipients: three grafts). Graft function was maintained in 80% at [median (interquartile range)] 24 (13.5-36) months postfirst transplant. Severe hypoglycemia was reduced from 20 (7-50) episodes/patient-year pretransplant to 0.3 (0-1.6) episodes/patient-year posttransplant (p < 0.001). Resolution of impaired hypoglycemia awareness was confirmed [pretransplant: Gold score 6 (5-7); 24 (13.5-36) months: 3 (1.5-4.5); p < 0.03]. Target HbA1c of <7.0% was attained/maintained in 70% of recipients [pretransplant: 8.0 (7.0-9.6)%; 24 (13.5-36) months: 6.2 (5.7-8.4)%; p < 0.001], with 60% reduction in insulin dose [pretransplant: 0.51 (0.41-0.62) units/kg; 24 (13.5-36) months: 0.20 (0-0.37) units/kg; p < 0.001]. Metabolic outcomes were comparable 12 months posttransplant in those receiving transported versus only locally isolated islets [12 month stimulated C-peptide: transported 788 (114-1764) pmol/L (n = 9); locally isolated 407 (126-830) pmol/L (n = 11); p = 0.32]. Metabolic goals have been attained within the equitably available, fully integrated UK islet transplant program with both transported and locally isolated preparations.
Collapse
|
|
12 |
44 |
8
|
Choudhary OP, Choudhary P, Singh I. India's COVID-19 vaccination drive: key challenges and resolutions. THE LANCET INFECTIOUS DISEASES 2021; 21:1483-1484. [PMID: 34529961 PMCID: PMC8437681 DOI: 10.1016/s1473-3099(21)00567-3] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 07/20/2021] [Accepted: 08/16/2021] [Indexed: 11/15/2022]
|
|
4 |
41 |
9
|
Beato-Víbora P, Yeoh E, Rogers H, Hopkins D, Amiel SA, Choudhary P. Sustained benefit of continuous subcutaneous insulin infusion on glycaemic control and hypoglycaemia in adults with Type 1 diabetes. Diabet Med 2015. [PMID: 26213236 DOI: 10.1111/dme.12869] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
AIM To evaluate the sustainability of the benefits of continuous subcutaneous insulin infusion therapy in routine practice in a cohort of adults with diabetes. METHODS The clinical records of all adults starting continuous subcutaneous insulin infusion over 12 years at our centre were included in this study. Baseline and mean annual HbA(1c) levels were recorded. The frequency of mild-to-moderate and severe hypoglycaemia and hypoglycaemia awareness were analysed in a subgroup. RESULTS Adequate data were available from 327 patients, of whom 71% were female. The patients' mean ± sd age was 41 ± 14 years, the mean ± sd (range) follow-up for continuous subcutaneous insulin infusion was 4.3 ± 2.7 (1-12) years. The mean ± sd HbA(1c) concentration fell by 8 ± 5 mmol/mol (0.7 ± 0.5%) at year 1 [to 63 ± 12 mmol/mol from 70 ± 18 mmol/mol (7.9 ± 1.1% from 8.6 ± 1.6%); P < 0.0005], sustained to year 5. In patients with initial poor control, HbA(1c) dropped by 12 ± 11 mmol/mol (1.1 ± 1.0%; P < 0.0005) at year 1, sustained to year 6. The percentage of patients with ≥ 5 mild to moderate hypoglycaemic episodes per week fell from 29 to 12% (n = 163; P = 0.006). In the subgroup (n = 87; follow-up 2.5 ± mean ± sd 1.1 years), the frequency of severe hypoglycaemia fell from 0.6 ± 1.7 episodes per patient per year to 0.3 ± 0.9 (P = 0.047). Of 24 patients with impaired awareness of hypoglycaemia (Gold score ≥ 4), the mean ± sd Gold score improved from 4.9 ± 0.9 to 3.8 ± 1.7 (P = 0.011). Nine people regained awareness. No deterioration in HbA(1c) was seen in the hypoglycaemia-prone groups. CONCLUSIONS The benefits of continuous subcutaneous insulin infusion with regard to improving glycaemic control and reducing hypoglycaemia frequency, along with improvement in hypoglycaemia awareness without deterioration in glycaemic control, can be sustained over several years in clinical practice.
Collapse
|
Observational Study |
10 |
40 |
10
|
Choudhary P, Khanna SM, Jain PK, Bharadwaj C, Kumar J, Lakhera PC, Srinivasan R. Genetic structure and diversity analysis of the primary gene pool of chickpea using SSR markers. GENETICS AND MOLECULAR RESEARCH 2012; 11:891-905. [PMID: 22576917 DOI: 10.4238/2012.april.10.5] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Members of the primary gene pool of the chickpea, including 38 accessions of Cicer arietinum, six of C. reticulatum and four of C. echinospermum grown in India were investigated using 100 SSR markers to analyze their genetic structure, diversity and relationships. We found considerable diversity, with a mean of 4.8 alleles per locus (ranging from 2 to 11); polymorphic information content ranged from 0.040 to 0.803, with a mean of 0.536. Most of the diversity was confined to the wild species, which had higher values of polymorphic information content, gene diversity and heterozygosity than the cultivated species, suggesting a narrow genetic base for cultivated chickpea. An unrooted neighbor-joining tree, principal coordinate analysis and population structure analysis revealed differentiation between the cultivated accessions and the wild species; three cultivated accessions were in an intermediate position, demonstrating introgression within the cultivated group. Better understanding of the structure, diversity and relationships within and among the members of this primary gene pool will contribute to more efficient identification, conservation and utilization of chickpea germplasm for allele mining, association genetics, mapping and cloning gene(s) and applied breeding to widen the genetic base of this cultivated species, for the development of elite lines with superior yield and improved adaptation to diverse environments.
Collapse
|
Research Support, Non-U.S. Gov't |
13 |
37 |
11
|
|
|
14 |
35 |
12
|
de Galan BE, McCrimmon RJ, Ibberson M, Heller SR, Choudhary P, Pouwer F, Speight J, Carlton J, Pieber TR, Rosilio M, Tack CJ, Müllenborn M. Reducing the burden of hypoglycaemia in people with diabetes through increased understanding: design of the Hypoglycaemia REdefining SOLutions for better liVEs (Hypo-RESOLVE) project. Diabet Med 2020; 37:1066-1073. [PMID: 31970814 PMCID: PMC7317819 DOI: 10.1111/dme.14240] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/16/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND Hypoglycaemia is the most frequent complication of treatment with insulin or insulin secretagogues in people with diabetes. Severe hypoglycaemia, i.e. an event requiring external help because of cognitive dysfunction, is associated with a higher risk of adverse cardiovascular outcomes and all-cause mortality, but underlying mechanism(s) are poorly understood. There is also a gap in the understanding of the clinical, psychological and health economic impact of 'non-severe' hypoglycaemia and the glucose level below which hypoglycaemia causes harm. AIM To increase understanding of hypoglycaemia by addressing the above issues over a 4-year period. METHODS Hypo-RESOLVE is structured across eight work packages, each with a distinct focus. We will construct a large, sustainable database including hypoglycaemia data from >100 clinical trials to examine predictors of hypoglycaemia and establish glucose threshold(s) below which hypoglycaemia constitutes a risk for adverse biomedical and psychological outcomes, and increases healthcare costs. We will also investigate the mechanism(s) underlying the antecedents and consequences of hypoglycaemia, the significance of glucose sensor-detected hypoglycaemia, the impact of hypoglycaemia in families, and the costs of hypoglycaemia for healthcare systems. RESULTS The outcomes of Hypo-RESOLVE will inform evidence-based definitions regarding the classification of hypoglycaemia in diabetes for use in daily clinical practice, future clinical trials and as a benchmark for comparing glucose-lowering interventions and strategies across trials. Stakeholders will be engaged to achieve broadly adopted agreement. CONCLUSION Hypo-RESOLVE will advance our understanding and refine the classification of hypoglycaemia, with the ultimate aim being to alleviate the burden and consequences of hypoglycaemia in people with diabetes.
Collapse
|
research-article |
5 |
30 |
13
|
Little SA, Leelarathna L, Barendse SM, Walkinshaw E, Tan HK, Lubina Solomon A, de Zoysa N, Rogers H, Choudhary P, Amiel SA, Heller SR, Evans M, Flanagan D, Speight J, Shaw JAM. Severe hypoglycaemia in type 1 diabetes mellitus: underlying drivers and potential strategies for successful prevention. Diabetes Metab Res Rev 2014; 30:175-90. [PMID: 24185859 DOI: 10.1002/dmrr.2492] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2013] [Revised: 10/23/2013] [Accepted: 10/25/2013] [Indexed: 02/03/2023]
Abstract
Hypoglycaemia remains an over-riding factor limiting optimal glycaemic control in type 1 diabetes. Severe hypoglycaemia is prevalent in almost half of those with long-duration diabetes and is one of the most feared diabetes-related complications. In this review, we present an overview of the increasing body of literature seeking to elucidate the underlying pathophysiology of severe hypoglycaemia and the limited evidence behind the strategies employed to prevent episodes. Drivers of severe hypoglycaemia including impaired counter-regulation, hypoglycaemia-associated autonomic failure, psychosocial and behavioural factors and neuroimaging correlates are discussed. Treatment strategies encompassing structured education, insulin analogue regimens, continuous subcutaneous insulin infusion pumps, continuous glucose sensing and beta-cell replacement therapies have been employed, yet there is little randomized controlled trial evidence demonstrating effectiveness of new technologies in reducing severe hypoglycaemia. Optimally designed interventional trials evaluating these existing technologies and using modern methods of teaching patients flexible insulin use within structured education programmes with the specific goal of preventing severe hypoglycaemia are required. Individuals at high risk need to be monitored with meticulous collection of data on awareness, as well as frequency and severity of all hypoglycaemic episodes.
Collapse
|
Review |
11 |
29 |
14
|
Wilmot EG, Lumb A, Hammond P, Murphy HR, Scott E, Gibb FW, Platts J, Choudhary P. Time in range: A best practice guide for UK diabetes healthcare professionals in the context of the COVID-19 global pandemic. Diabet Med 2021; 38:e14433. [PMID: 33073388 PMCID: PMC7645943 DOI: 10.1111/dme.14433] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 09/21/2020] [Accepted: 10/15/2020] [Indexed: 12/15/2022]
Abstract
The emergence of continuous glucose monitoring has driven improvements in glycaemic control and quality of life for people with diabetes. Recent changes in access to continuous glucose monitoring systems within UK health services have increased the number of people able to benefit from these technologies. The COVID-19 pandemic has created an opportunity for diabetes healthcare professionals to use continuous glucose monitoring technology to remotely deliver diabetes services to support people with diabetes. This opportunity can be maximized with improved application and interpretation of continuous glucose monitoring-generated data. Amongst the diverse measures of glycaemic control, time in range is considered to be of high value in routine clinical care because it is actionable and is visibly responsive to changes in diabetes management. Importantly, it is also been linked to the risk of developing complications associated with diabetes and can be understood by people with diabetes and healthcare professionals alike. The 2019 International Consensus on Time in Range has established a series of target glucose ranges and recommendations for time spent within these ranges that is consistent with optimal glycaemic control. The recommendations cover people with type 1 or type 2 diabetes, with separate targets indicated for elderly people or those at higher risk from hypoglycaemia, as well as for women with type 1 diabetes during pregnancy. The aim of this best practice guide was to clarify the intent and purpose of these international consensus recommendations and to provide practical insights into their implementation in UK diabetes care.
Collapse
|
Review |
4 |
28 |
15
|
Bahuguna A, Choudhary P, Chhabra T, Krishnan V. Ammonia-Doped Polyaniline-Graphitic Carbon Nitride Nanocomposite as a Heterogeneous Green Catalyst for Synthesis of Indole-Substituted 4 H-Chromenes. ACS OMEGA 2018; 3:12163-12178. [PMID: 31459291 PMCID: PMC6645668 DOI: 10.1021/acsomega.8b01687] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Accepted: 09/13/2018] [Indexed: 05/21/2023]
Abstract
A nanocomposite of polyaniline with graphitic carbon nitride (GCN) nanosheets has been synthesized by a facile oxidative polymerization of an aniline monomer and GCN to demonstrate its potential to catalyze the synthesis of various indole-substituted 4H-chromenes. The synthesized nanocomposite was thoroughly characterized using different spectroscopic techniques to confirm the morphology and composition. Subsequently, the fabricated nanocomposite was used as a heterogeneous catalyst to synthesize several bioactive indole-substituted 4H-chromenes in an aqueous medium. Organic transformation under benign and environmentally sustainable conditions is of paramount importance in the view of growing environmental pollution. Water is the universal Green solvent and has been a preferred choice of nature to perform various reactions. The catalyst developed in this work showed very good recyclability and adaptability for the synthesis of various medicinally significant indole-substituted 4H-chromenes. This multicomponent reaction imparts very high atom economy (94%) and low environmental factor (0.13).
Collapse
|
research-article |
7 |
28 |
16
|
Choudhary P, Campbell F, Joule N, Kar P. A Type 1 diabetes technology pathway: consensus statement for the use of technology in Type 1 diabetes. Diabet Med 2019; 36:531-538. [PMID: 30773681 DOI: 10.1111/dme.13933] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/14/2019] [Indexed: 01/11/2023]
Abstract
In both adults and children with diabetes, technologies such as continuous subcutaneous insulin infusion using insulin pumps and continuous glucose monitoring can help improve diabetes control, reduce hypoglycaemia and improve quality of life. Access to these technologies in the UK is very variable. Some technologies are recommended by the National Institute for Health and Care Excellence, while others have not been appraised, and new technologies are emerging all the time. Additionally, different guidelines for adults and children further complicate access to diabetes technology in the transition from paediatric to adult care. Against this background, Diabetes UK and NHS England have brought together a multidisciplinary group of experts, including clinicians and people with diabetes, to develop this consensus guideline, combining the different technologies into a common pathway to aid clinical and policy decision-making. We created a pathway that supports the incremental addition of technology as monotherapy and then dual therapy in the same way that we incrementally add in therapeutic agents to support people with Type 2 diabetes to achieve their personalized glycaemic targets. The pathway emphasizes the importance of structured education, specialist support and appropriate access to psychological therapies, as essential pillars for optimized use of diabetes-related technology, and recommends the re-evaluation of its use when the individual is unable either to use the technology appropriately or to achieve the intended outcomes. This pathway is endorsed by UK-wide clinical and patient associations and we recommend that providers and commissioners use it to ensure the right individual with diabetes has access to the right technology in a timely way to help achieve better outcomes.
Collapse
|
Practice Guideline |
6 |
25 |
17
|
Saied AA, Dhawan M, Metwally AA, Fahrni ML, Choudhary P, Choudhary OP. Disease History, Pathogenesis, Diagnostics, and Therapeutics for Human Monkeypox Disease: A Comprehensive Review. Vaccines (Basel) 2022; 10:2091. [PMID: 36560502 PMCID: PMC9784156 DOI: 10.3390/vaccines10122091] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 11/28/2022] [Accepted: 11/30/2022] [Indexed: 12/13/2022] Open
Abstract
The monkeypox disease is a zoonotic-infectious disease that transmits between animals and humans. It is caused by a double-stranded DNA virus belonging to the Orthopoxvirus genus that is closely related to the variola virus -the causative agent of smallpox. Although monkeypox infections were endemic to Western and Central Africa, the newly emerging monkeypox outbreak spread to more than 90 non-African countries. With the exception of the PCR-confirmed case of a return from Nigeria to the United Kingdom, the ongoing outbreak is largely unrelated to travel. In the most recent wave, cases are characteristically males in their thirties. Risk factors include close and particularly sexual contact with an infected person, and contact with fomites, infected animals or aerosolized-infectious material. Clinical diagnosis of monkeypox is confirmed with nucleic-acid amplification testing of samples originating from vesicles or genital lesions and using real-time or conventional PCR. Other methods, such as electron microscopy, immunohistochemistry, and virus culture are costly and time-consuming. In addition to timely diagnosis and contact tracing, restrictive measures to limit spread, such as isolation of infected patients, preventing contact with wild animals, and isolation of animals suspected to be viral reservoirs have shown promise. Although there are no specific treatments for monkeypox disease, the experience with smallpox suggests that the vaccinia vaccine, cidofovir, tecovirimat, and vaccinia immune globulin (IVG) may be beneficial for monkeypox treatment. In this review, we provide an update on the human-monkeypox disease with a special emphasis on its pathogenesis, prevention, diagnostics, and therapeutic measures.
Collapse
|
Review |
3 |
23 |
18
|
Thabit H, Elleri D, Leelarathna L, Allen JM, Lubina-Solomon A, Stadler M, Walkinshaw E, Iqbal A, Choudhary P, Wilinska ME, Barnard KD, Heller SR, Amiel SA, Evans ML, Dunger DB, Hovorka R. Unsupervised home use of an overnight closed-loop system over 3-4 weeks: a pooled analysis of randomized controlled studies in adults and adolescents with type 1 diabetes. Diabetes Obes Metab 2015; 17:452-8. [PMID: 25492378 PMCID: PMC4510702 DOI: 10.1111/dom.12427] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2014] [Revised: 12/01/2014] [Accepted: 12/04/2014] [Indexed: 12/25/2022]
Abstract
AIMS To compare overnight closed-loop and sensor-augmented pump therapy in patients with type 1 diabetes by combining data collected during free-living unsupervised randomized crossover home studies. METHODS A total of 40 participants with type 1 diabetes, of whom 24 were adults [mean ± standard deviation (s.d.) age 43 ± 12 years and glycated haemoglobin (HbA1c) 8.0 ± 0.9%] and 16 were adolescents (mean ± s.d. age 15.6 ± 3.6 years and HbA1c 8.1 ± 0.8%), underwent two periods of sensor-augmented pump therapy in the home setting, in combination with or without an overnight closed-loop insulin delivery system that uses a model predictive control algorithm to direct insulin delivery. The order of the two interventions was random; each period lasted 4 weeks in adults and 3 weeks in adolescents. The primary outcome was time during which sensor glucose readings were in the target range of 3.9-8.0 mmol/l. RESULTS The proportion of time when sensor glucose was in the target range (3.9-8.0 mmol/l) overnight (between 24:00 and 08:00 hours) was 18.5% greater during closed-loop insulin delivery than during sensor-augmented therapy (p < 0.001). Closed-loop therapy significantly reduced mean overnight glucose levels by 0.9 mmol/l (p < 0.001), with no difference in glycaemic variability, as measured by the standard deviation of sensor glucose. Time spent above the target range was reduced (p = 0.001), as was time spent in hypoglycaemia (<3.9 mmol/l; p = 0.014) during closed-loop therapy. Lower mean overnight glucose levels during closed-loop therapy were brought about by increased overnight insulin delivery (p < 0.001) without changes to the total daily delivery (p = 0.84). CONCLUSION Overnight closed-loop insulin therapy at home in adults and adolescents with type 1 diabetes is feasible, showing improvements in glucose control and reducing the risk of nocturnal hypoglycaemia.
Collapse
|
Comparative Study |
10 |
23 |
19
|
Ahluwalia P, Tewari K, Choudhary P. Studies on the effects of monosodium glutamate (MSG) on oxidative stress in erythrocytes of adult male mice. Toxicol Lett 1996; 84:161-5. [PMID: 8600616 DOI: 10.1016/0378-4274(95)03612-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Subcutaneous administration of monosodium glutamate (MSG) to normal adult male mice for 6 days at dose levels of 4 and 8 mg/g body weight caused a significant increase in erythrocyte glucose content accompanied by increased lipid peroxidation. The levels of total glutathione and protein-bound glutathione were significantly increased in the erythrocytes, whereas non-protein glutathione was significantly decreased. The administration of 4 and 8 mg/g body weight of MSG significantly increased the activities of glutathione reductase (GR), glutathione-S-transferase (GST) and glutathione peroxidase (GPX). It was observed that MSG, above 4 mg/g body weight, produced oxidative stress which was counteracted by the body by maintaining the level of glutathione, which was done by increasing the activity of its metabolizing enzymes.
Collapse
|
|
29 |
21 |
20
|
Choudhary P, Malik VB, Puri S, Ahluwalia P. Studies on the effects of monosodium glutamate on hepatic microsomal lipid peroxidation, calcium, ascorbic acid and glutathione and its dependent enzymes in adult male mice. Toxicol Lett 1996; 89:71-6. [PMID: 8952714 DOI: 10.1016/s0378-4274(96)03786-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Daily administration of monosodium glutamate (MSG) to adult male mice subcutaneously, for 6 days, at dose levels of 4 and 8 mg/g body weight, significantly increased lipid peroxidation in the hepatic microsomes, as seen 31 days after the last injection. A highly significant increase was observed in the level of hepatic calcium and ascorbic acid. The glutathione (GSH) content was significantly decreased but the activities of glutathione dependent enzymes like GR, GPX, GSTs were found to be significantly increased. These observations suggested that MSG at dose levels above 4 mg/g body weight induced oxidative stress in hepatic microsomes. Attempts to maintain the redox state of the cell are suggested by increase in the ascorbic acid content and the activities of glutathione dependent enzymes.
Collapse
|
|
29 |
20 |
21
|
Choudhary P, Hsu CJ, Grieve S, Smillie C, Singarayar S, Semsarian C, Richmond D, Muthurangu V, Celermajer DS, Puranik R. Improving the diagnosis of LV non-compaction with cardiac magnetic resonance imaging. Int J Cardiol 2014; 181:430-6. [PMID: 25569272 DOI: 10.1016/j.ijcard.2014.12.053] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2014] [Accepted: 12/21/2014] [Indexed: 12/21/2022]
Abstract
BACKGROUND Current diagnostic criteria for left ventricular non-compaction (LVNC) poorly correlate with clinical outcomes. We aimed to develop a cardiac magnetic resonance (CMR) based semi-automated technique for quantification of non-compacted (NC) and compacted (C) masses and to ascertain their relationships to global and regional LV function. METHODS We analysed CMR data from 30 adults with isolated LVNC and 20 controls. NC and C masses were measured using relative signal intensities of myocardium and blood pool. Global and regional LVNC masses was calculated and correlated with both global and regional LV systolic function as well as occurrence of arrhythmia. RESULTS LVNC patients had significantly higher end-systolic (ES) and end-diastolic (ED) NC:C ratios compared to controls (ES 0.21 [SD 0.09] vs. 0.12 [SD 0.02], p<0.001; ED 0.39 [SD 0.08] vs. 0.26 [SD 0.05], p<0.001). NC:C ratios correlated inversely with global ejection fraction, with a stronger correlation in ES vs. ED (r=-0.58, p<0.001 vs. r=-0.30, p=0.03). ES basal, mid and apical NC:C ratios also showed a significant inverse correlation with global LV ejection fraction (ES basal r=-0.29, p=0.04; mid-ventricular r=-0.50, p<0.001 and apical r=-0.71, p<0.001). Upon ROC testing, an ES NC:C ratio of 0.16 had a sensitivity of 70% and a specificity of 95% for detection of significant LVNC. Patients with sustained ventricular tachycardia had a significantly higher ES NC:C ratio (0.31 [SD 0.18] vs. 0.20 [SD 0.06], p=0.02). CONCLUSIONS The NC:C ratio derived from relative signal intensities of myocardium and blood pool improves the ability to detect clinically relevant NC compared to previous CMR techniques.
Collapse
|
Research Support, Non-U.S. Gov't |
11 |
19 |
22
|
Garrett CJ, Choudhary P, Amiel SA, Fonagy P, Ismail K. Recurrent diabetic ketoacidosis and a brief history of brittle diabetes research: contemporary and past evidence in diabetic ketoacidosis research including mortality, mental health and prevention. Diabet Med 2019; 36:1329-1335. [PMID: 31418474 DOI: 10.1111/dme.14109] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/13/2019] [Indexed: 12/11/2022]
Abstract
Pharmacological, technological and educational approaches have advanced the treatment of Type 1 diabetes in the last four decades and yet diabetic ketoacidosis (DKA) continues to be a leading cause of admission in Type 1 diabetes. This article begins by reviewing the contemporary epidemiological evidence in DKA. It highlights a rise in DKA episodes in the last two decades, with DKA continuing to be the leading cause of death in young people with Type 1 diabetes, and that DKA episodes are a marker for subsequent all-cause mortality. It also summarizes the limited evidence base for DKA prevention and associations with psychopathology. To emphasize the importance of this group with high-risk Type 1 diabetes and the degree to which they have been overlooked in the past two decades, the article summarizes the research literature of recurrent DKA during 1976-1991 when it was extensively investigated as part of the phenomenon of 'brittle diabetes'. This period saw numerous basic science studies investigating the pathophysiology of recurrent DKA. Subsequently, research centres published their experiences of brittle diabetes research participants manipulating their treatment under research conditions. Unfortunately, the driver for this behaviour and whether it was indicative of other people with ketoacidosis was not pursued. In summary, we suggest there has been a stasis in the approach to recurrent DKA prevention, which is likely linked to historical cases of mass sabotage of brittle diabetes research. Further investigation is required to clarify possible psychological characteristics that increase the risk of DKA and thereby targets for DKA prevention.
Collapse
|
Review |
6 |
18 |
23
|
McCombe A, Touma F, Jackson D, Canniffe C, Choudhary P, Pressley L, Tanous D, Robinson PJ, Celermajer D. Sudden cardiac death in adults with congenitally corrected transposition of the great arteries. Open Heart 2016; 3:e000407. [PMID: 27493760 PMCID: PMC4947757 DOI: 10.1136/openhrt-2016-000407] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Revised: 04/30/2016] [Accepted: 05/24/2016] [Indexed: 01/03/2023] Open
Abstract
Background Congenitally corrected transposition of the great arteries (ccTGA) is a rare congenital heart disease. There have been only few reports of sudden cardiac death (SCD) in patients with ccTGA and reasonable ventricular function. Methods A retrospective review of the medical records of all patients attending our adult congenital heart centre, with known ccTGA. Results From a database of over 3500 adult patients with congenital heart disease, we identified 39 (∼1%) with ccTGA and ‘two-ventricle’ circulations. 65% were male. The mean age at diagnosis was 12.4±11.4 years and the mean age at last time of review was 34.3±11.3 years. 24 patients (56%) had a history of surgical intervention. 8 (19%) had had pacemaker implantation and 2 had had a defibrillator implanted for non-sustained ventricular tachycardia (NSVT). In 544 years of patient follow-up, there had been five cases of SCD in our population; 1 death per 109 patient-years. Two of these patients had had previously documented supraventricular or NSVT. However, they were all classified as New York Heart Association (NYHA) class I or II, and systemic (right) ventricular function had been recorded as normal, mildly or mildly–moderately impaired, at most recent follow-up. Conclusions Our experience suggests the need for improved risk stratification and/or surveillance for malignant arrhythmia in adults with ccTGA, even in those with reasonable functional class on ventricular function.
Collapse
|
Journal Article |
9 |
18 |
24
|
Chand H, Choudhary P, Kumar A, Kumar A, Krishnan V. Atmospheric pressure conversion of carbon dioxide to cyclic carbonates using a metal-free Lewis acid-base bifunctional heterogeneous catalyst. J CO2 UTIL 2021. [DOI: 10.1016/j.jcou.2021.101646] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
|
4 |
16 |
25
|
Choudhary P, Davies C, Emery CJ, Heller SR. Do high fasting glucose levels suggest nocturnal hypoglycaemia? The Somogyi effect-more fiction than fact? Diabet Med 2013; 30:914-7. [PMID: 23672623 DOI: 10.1111/dme.12175] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2012] [Revised: 01/09/2013] [Accepted: 03/13/2013] [Indexed: 11/27/2022]
Abstract
AIMS The Somogyi effect postulates that nocturnal hypoglycaemia causes fasting hyperglycaemia attributable to counter-regulatory hormone release. Although most published evidence has failed to support this hypothesis, this concept remains firmly embedded in clinical practice and often prevents patients and professionals from optimizing overnight insulin. Previous observational data found lower fasting glucose was associated with nocturnal hypoglycaemia, but did not assess the probability of infrequent individual episodes of rebound hypoglycaemia. We analysed continuous glucose monitoring data to explore its prevalence. METHODS We analysed data from 89 patients with Type 1 diabetes who participated in the UK Hypoglycaemia study. We compared fasting capillary glucose following nights with and without nocturnal hypoglycaemia (sensor glucose < 3.5 mmol/l). RESULTS Fasting capillary blood glucose was lower after nights with hypoglycaemia than without [5.5 (3.0) vs. 14.5 (4.5) mmol/l, P < 0.0001], and was lower on nights with more severe nocturnal hypoglycaemia [5.5 (3.0) vs. 8.2 (2.3) mmol/l; P = 0.018 on nights with nadir sensor glucose of < 2.2 mmol/l vs. 3.5 mmol/l]. There were only two instances of fasting capillary blood glucose > 10 mmol/l after nocturnal hypoglycaemia, both after likely treatment of the episode. When fasting capillary blood glucose is < 5 mmol/l, there was evidence of nocturnal hypoglycaemia on 94% of nights. CONCLUSION Our data indicate that, in clinical practice, the Somogyi effect is rare. Fasting capillary blood glucose ≤ 5 mmol/l appears an important indicator of preceding silent nocturnal hypoglycaemia.
Collapse
|
Comparative Study |
12 |
16 |