1
|
Gruslova AB, Singh S, Hoyt T, Vela D, Vengrenyuk Y, Buja LM, Litovsky S, Michalek J, Maehara A, Kini A, Akasaka T, Garcia-Garcia HM, Jang IK, Dijkstra J, Raber L, Milner TE, Feldman MD. Accuracy of OCT Core Labs in Identifying Vulnerable Plaque. JACC Cardiovasc Imaging 2024; 17:448-450. [PMID: 37943235 DOI: 10.1016/j.jcmg.2023.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 09/26/2023] [Accepted: 10/12/2023] [Indexed: 11/10/2023]
|
2
|
Teichman JMH, Katta N, Milner TE. Editorial Comment. J Urol 2024; 211:454. [PMID: 38224054 DOI: 10.1097/ju.0000000000003833.01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Accepted: 12/14/2023] [Indexed: 01/16/2024]
|
3
|
Gruslova AB, Inanc IH, Cilingiroglu M, Katta N, Milner TE, Feldman MD. Review of intravascular lithotripsy for treating coronary, peripheral artery, and valve calcifications. Catheter Cardiovasc Interv 2024; 103:295-307. [PMID: 38091341 DOI: 10.1002/ccd.30933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 11/29/2023] [Accepted: 12/03/2023] [Indexed: 01/31/2024]
Abstract
Management of intracoronary calcium (ICC) continues to be a challenge for interventional cardiologists. There have been significant advances in calcium treatment devices. However, there still exists a knowledge gap regarding which devices to choose for the treatment of ICC. The purpose of this manuscript is to review the principles of intravascular lithotripsy (IVL) and clinical data. The technique of IVL will then be compared to alternative calcium treatment devices. Clinical data will be reviewed concerning the treatment of coronary, peripheral artery and valvular calcifications. Controversies to be discussed include how to incorporate IVL into your practice, what is the best approach for treating calcium subtypes, how to approach under-expanded stents, what is the ideal technique for performing IVL, how safe is IVL, whether imaging adds value when performing IVL, and how IVL fits into a treatment program for peripheral arteries and calcified valves.
Collapse
|
4
|
Gruslova AB, Katta N, Nolen D, Jenney S, Vela D, Buja M, Cilingiroglu M, Seddighi Y, Han HC, Milner TE, Feldman MD. Intravascular laser lithotripsy for calcium fracture in human coronary arteries. EUROINTERVENTION 2023; 19:e913-e922. [PMID: 38060282 PMCID: PMC10722992 DOI: 10.4244/eij-d-23-00487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 10/11/2023] [Indexed: 12/08/2023]
Abstract
BACKGROUND Electrical intravascular lithotripsy (E-IVL) uses shock waves to fracture calcified plaque. AIMS We aimed to demonstrate the ability of laser IVL (L-IVL) to fracture calcified plaques in ex vivo human coronary arteries and to identify and evaluate the mechanisms for increased vessel compliance. METHODS Shock waves were generated by a Ho:YAG (Holmium: yttrium-aluminium-garnet) laser (2 J, 5 Hz) and recorded by a high-speed camera and pressure sensor. Tests were conducted on phantoms and 19 fresh human coronary arteries. Before and after L-IVL, arterial compliance and optical coherence tomography (OCT) pullbacks were recorded, followed by histology. Additionally, microcomputed tomography (micro-CT) and scanning electron microscopy (SEM) were performed. Finite element models (FEM) were utilised to examine the mechanism of L-IVL. RESULTS Phantom cracks were obtained using 230 μm and 400 μm fibres with shock-wave pressures of 84±5.0 atm and 62±0.4 atm, respectively. Post-lithotripsy, calcium plaque modifications, including fractures and debonding, were identified by OCT in 78% of the ex vivo calcified arteries (n=19). Histological analysis revealed calcium microfractures (38.7±10.4 μm width) in 57% of the arteries which were not visible by OCT. Calcium microfractures were verified by micro-CT and SEM. The lumen area increased from 2.9±0.4 to 4.3±0.8 mm2 (p<0.01). Arterial compliance increased by 2.3±0.6 atm/ml (p<0.05). FEM simulations suggest that debonding and intimal tears are additional mechanisms for increased arterial compliance. CONCLUSIONS L-IVL has the capability to increase calcified coronary artery compliance by multiple mechanisms.
Collapse
|
5
|
Li Y, Blakeley J, Ly I, Berman Y, Lau J, Wolkenstein P, Bergqvist C, Jia W, Milner TE, Katta N, Durkin AJ, Kennedy GT, Rowland R, Romo CG, Fleming J, Kelly KM. Current and Emerging Imaging Techniques for Neurofibromatosis Type 1-Associated Cutaneous Neurofibromas. J Invest Dermatol 2023:S0022-202X(23)01988-7. [PMID: 37330718 DOI: 10.1016/j.jid.2023.03.1681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 02/25/2023] [Accepted: 03/08/2023] [Indexed: 06/19/2023]
Abstract
A consistent set of measurement techniques must be applied to reliably and reproducibly evaluate the efficacy of treatments for cutaneous neurofibromas (cNFs) in people with neurofibromatosis type 1 (NF1). cNFs are neurocutaneous tumors that are the most common tumor in people with NF1 and represent an area of unmet clinical need. This review presents the available data regarding approaches in use or development to identify, measure, and track cNFs, including calipers, digital imaging, and high-frequency ultrasound sonography. We also describe emerging technologies such as spatial frequency domain imaging and the application of imaging modalities such as optical coherence tomography that may enable the detection of early cNFs and prevention of tumor-associated morbidity.
Collapse
|
6
|
King JB, Katta N, Parekh SH, Milner TE, Tunnell JW. Erratum: Tissue harvest with a laser microbiopsy (Erratum). JOURNAL OF BIOMEDICAL OPTICS 2023; 28:029801. [PMID: 36864902 PMCID: PMC9973560 DOI: 10.1117/1.jbo.28.2.029801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
[This corrects the article DOI: 10.1117/1.JBO.27.12.125001.].
Collapse
|
7
|
King JB, Katta N, Parekh SH, Milner TE, Tunnell JW. Tissue harvest with a laser microbiopsy. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:125001. [PMID: 36530344 PMCID: PMC9749420 DOI: 10.1117/1.jbo.27.12.125001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 11/22/2022] [Indexed: 06/17/2023]
Abstract
Significance Traditional pathology workflow suffers from limitations including biopsy invasiveness, small fraction of large tissue samples being analyzed, and complex and time-consuming processing. Aim We address limitations of conventional pathology workflow through development of a laser microbiopsy device for minimally invasive harvest of sub-microliter tissue volumes. Laser microbiopsy combined with rapid diagnostic methods, such as virtual hematoxylin and eosin (H&E) imaging has potential to provide rapid minimally invasive tissue diagnosis. Approach Laser microbiopsies were harvested using an annular shaped Ho:YAG laser beam focused onto the tissue surface. As the annulus was ablated, the tissue section in the center of the annulus was ejected and collected directly onto a glass slide for analysis. Cryogen spray cooling was used before and after laser harvest to limit thermal damage. Microbiopsies were collected from porcine skin and kidney. Harvested microbiopsies were imaged with confocal microscopy and digitally false colored to provide virtual H&E images. Results Microbiopsies were successfully harvested from porcine skin and kidney. Computational and experimental results show the benefit of cryogen pre- and post-cooling to limit thermal damage. Virtual H&E images of microbiopsies retained observable cellular features including cell nuclei. Conclusions Laser microbiopsy with virtual H&E imaging shows promise as a potential rapid and minimally invasive tool for biopsy and diagnosis.
Collapse
|
8
|
Katta N, Estrada AD, McElroy AB, Milner TE. Er:YAG laser brain surgery with vascular specific coagulation. Lasers Surg Med 2022; 54:1107-1115. [PMID: 35946396 DOI: 10.1002/lsm.23591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 07/14/2022] [Accepted: 07/21/2022] [Indexed: 11/11/2022]
Abstract
BACKGROUND AND OBJECTIVE Erbium:yttrium-aluminum-garnet (Er:YAG) laser ablation can effectively resect water-bearing tissues. Application of Er:YAG resection in neurosurgery is complicated by unpredictable bleeding in surgical field. Recently, an integrated theranostic system combining a dual-wavelength laser surgery system using a thulium (Tm) fiber-laser for coagulation and Er:YAG for resection, combined with optical coherence tomography (OCT) guidance was demonstrated for the in vivo resection of tumor tissue. However, lateral thermal spread in the range of 100 seconds of micrometers is common due to lack of vascular specificity using a Tm fiber-laser for coagulation. In this study, a vascular specific ytterbium (Yb) fiber-laser is utilized for enhanced photocoagulation during in vivo neurosurgery improving the precision of Er:YAG tissue resection with minimal lateral thermal spread. METHODS Mice underwent stereotactic laser surgery with the proposed Yb/Er:YAG dual wavelength vascular specific neurosurgery in vivo. An OCT system (wavelength range 1310 ± 70 nm) and OCT derived angiography images were used to record cortical images to confirm the coagulation of blood vessels and guide subsequent Er:YAG resection steps. After the laser surgery, mice were killed, and histological analysis was carried out using hematoxylin and eosin staining and Nissl staining to compare the lateral thermal spread with our previously reported Tm/Er:YAG neurosurgery where a continuous wave Tm fiber-laser was used for coagulation. RESULTS Coagulation scheme using a Yb fiber-laser allowed stoppage of blood flow in disparately sized blood vessels encountered in the mice brain. Histological analysis of murine brain slices post Yb/Er:YAG laser surgery yielded lower thermal spread compared with Tm/Er:YAG laser surgery, maximizing the efficiency in both hemostasis (blood flow stoppage) and maximizing tissue ablation efficiency with minimal residual thermal damage zone. CONCLUSION In this study, a vascular specific coagulation scheme with Yb/Er:YAG dual-wavelength surgery is presented for neurosurgery. Additionally, Yb/Er:YAG study results are compared with that of a tissue coagulation approach in Tm/Er:YAG surgery previously reported to highlight improved coagulation, reduced nonspecific thermal damage and limited lateral thermal spread. Experimental results suggest that the developed dual-wavelength laser system can effectively resect neural tissues with high localization, minimal lateral thermal spread at the micrometer level while maintaining a bloodless surgical field.
Collapse
|
9
|
Katta N, Estrada AD, McErloy AB, Milner TE. Fiber-laser platform for precision brain surgery. BIOMEDICAL OPTICS EXPRESS 2022; 13:1985-1994. [PMID: 35519278 PMCID: PMC9045916 DOI: 10.1364/boe.449312] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 02/20/2022] [Accepted: 02/21/2022] [Indexed: 06/14/2023]
Abstract
Minimally invasive neurological surgeries are increasingly being sought after for treatment in neurological pathologies and oncology. A critical limitation in these minimally invasive procedures is lack of specialized tools that allow for space-time controlled delivery of sufficient energy for coagulation and cutting of tissue. Advent of fiber-lasers provide high average power with improved beam quality (lower M2), biocompatible silica fiber delivery, reduced cost of manufacturing, and radiant output stability over long operating periods. Despite these advancements, no fiber-laser based surgical tools are currently available for tissue resection in vivo. Here we demonstrate a first to our knowledge, fiber-laser platform for performing precise brain surgery in a murine brain model. In this study, our primary aims were to first demonstrate efficacy of fiber-lasers in performing precise blood-less surgery in a murine brain with limited non-specific thermal damage. Second, fiber-lasers' ability to deliver radiant energy through biocompatible silica fibers was explored in a murine brain model for blood less resection. A bench-top optical coherence tomography (OCT) guided fiber-laser platform was constructed with a stereotactic stage for performing precision brain surgery. A pulsed quasi-continuous wave ytterbium (Yb) fiber-laser (1.07 µm) was used to perform vascular specific coagulation while a pulsed nanosecond thulium fiber-laser (1.94 µm) was used to conduct bloodless cutting, all under the guidance of a swept-source OCT system centered at 1310 +/- 70 nm. Specialty linear and circular cuts were made in an in vivo murine brain for bloodless brain tissue resection. The two fiber-lasers were combined into a single biocompatible silica fiber to conduct brain surgery resection under the bench-top OCT system's imaging microscope. Vascular specific coagulation was demonstrated in all five mice studied. Bloodless linear cuts and point cuts were demonstrated in vivo. Histologically, thermal injury was measured to be less than 100 µm while a removal rate of close to 5 mm3/s was achieved with an average Tm fiber-laser power of 15 W. To the authors' knowledge, this is the first demonstration of a fiber-laser platform for conducting in vivo bloodless brain tissue resection with a pulsed thulium (Tm) fiber-laser and a quasi-continuous wave (QCW) Yb fiber-laser. The demonstrated fiber-laser platform, if successfully configured for use in the operating room (OR), can provide surgeons a tool for rapid removal of tissue while making surgical resections of brain regions more precise, and can be basis for a flexible cutting tool capable of reaching hard-to-operate regions.
Collapse
|
10
|
Milner TE, van Gemert MJC, Duco Jansen E. Ashley James Welch (A.J.). Lasers Surg Med 2022; 54:201. [PMID: 35049046 DOI: 10.1002/lsm.23520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 01/07/2022] [Indexed: 11/05/2022]
|
11
|
King JB, Katta N, Teichman JMH, Tunnell JW, Milner TE. Mechanisms of Pulse Modulated Holmium:YAG Lithotripsy. J Endourol 2021; 35:S29-S36. [PMID: 34910606 DOI: 10.1089/end.2021.0742] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Introduction: This study aimed at answering three research questions: (1) Under the experimental conditions studied, what is the dominant mechanism of Holmium:YAG lithotripsy with or without pulse modulation? (2) Under what circumstances can laser pulse modulation increase crater volume of stone ablation per joule of emitted radiant energy? (3) Are BegoStone phantoms a suitable model for laser lithotripsy studies? Materials and Methods: The research questions were addressed by ablation experiments with BegoStone phantoms and native stones. Experiments were performed under three stone conditions: dry stones in air, hydrated stones in air, and hydrated stones in water. Single pulses with and without pulse modulation were applied. For each pulse mode, temporal profile, transmission through 1 mm water, and cavitation bubble collapse pressures were measured and compared. For each stone condition and pulse mode, stones were ablated with a fiber separation distance of 1 mm and crater volumes were measured using optical coherence tomography. Results: Pulses with and without pulse modulation had high (>80%) transmission through 1 mm of water. Pulses without pulse modulation generated much higher peak pressures than those with pulse modulation (62.3 vs 11.4 bar). Pulse modulation resulted in similar or larger craters than without pulse modulation. Trends in BegoStone crater volumes differed from trends in native stones. Conclusions: This results of this study suggest that the dominant mechanism is photothermal with possible photoacoustic contributions for some stone compositions. Pulse modulation can increase ablation volume per joule of emitted radiant energy, but the effect may be composition specific. BegoStones showed unique infrared ablation characteristics compared with native stones and are not a suitable model for laser lithotripsy studies.
Collapse
|
12
|
Gruslova AB, Katta N, Cabe AG, Jenney SF, Valvano JW, Phillips TB, McElroy AB, LaSalle RK, Zahedivash A, Truskett VN, Viswanathan N, Feldman MD, Wettstein RB, Milner TE, Derdak S. Data automated bag breathing unit for COVID-19 ventilator shortages. Intensive Care Med Exp 2021; 9:54. [PMID: 34657982 PMCID: PMC8520856 DOI: 10.1186/s40635-021-00419-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Accepted: 09/24/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The COVID-19 pandemic has caused a global mechanical ventilator shortage for treatment of severe acute respiratory failure. Development of novel breathing devices has been proposed as a low cost, rapid solution when full-featured ventilators are unavailable. Here we report the design, bench testing and preclinical results for an 'Automated Bag Breathing Unit' (ABBU). Output parameters were validated with mechanical test lungs followed by animal model testing. RESULTS The ABBU design uses a programmable motor-driven wheel assembled for adult resuscitation bag-valve compression. ABBU can control tidal volume (200-800 ml), respiratory rate (10-40 bpm), inspiratory time (0.5-1.5 s), assist pressure sensing (- 1 to - 20 cm H2O), manual PEEP valve (0-20 cm H2O). All set values are displayed on an LCD screen. Bench testing with lung simulators (Michigan 1600, SmartLung 2000) yielded consistent tidal volume delivery at compliances of 20, 40 and 70 (mL/cm H2O). The delivered fraction of inspired oxygen (FiO2) decreased with increasing minute ventilation (VE), from 98 to 47% when VE was increased from 4 to 16 L/min using a fixed oxygen flow source of 5 L/min. ABBU was tested in Berkshire pigs (n = 6, weight of 50.8 ± 2.6 kg) utilizing normal lung model and saline lavage induced lung injury. Arterial blood gases were measured following changes in tidal volume (200-800 ml), respiratory rate (10-40 bpm), and PEEP (5-20 cm H2O) at baseline and after lung lavage. Physiological levels of PaCO2 (≤ 40 mm Hg [5.3 kPa]) were achieved in all animals at baseline and following lavage injury. PaO2 increased in lavage injured lungs in response to incremental PEEP (5-20 cm H2O) (p < 0.01). At fixed low oxygen flow rates (5 L/min), delivered FiO2 decreased with increased VE. CONCLUSIONS ABBU provides oxygenation and ventilation across a range of parameter settings that may potentially provide a low-cost solution to ventilator shortages. A clinical trial is necessary to establish safety and efficacy in adult patients with diverse etiologies of respiratory failure.
Collapse
|
13
|
Zhang J, Sans M, DeHoog RJ, Garza KY, King ME, Feider CL, Bensussan A, Keating MF, Lin JQ, Povilaitis SC, Katta N, Milner TE, Yu W, Nagi C, Dhingra S, Pirko C, Brahmbhatt KA, Van Buren G, Carter S, Thompson A, Grogan RH, Suliburk J, Eberlin LS. Clinical Translation and Evaluation of a Handheld and Biocompatible Mass Spectrometry Probe for Surgical Use. Clin Chem 2021; 67:1271-1280. [PMID: 34263289 DOI: 10.1093/clinchem/hvab098] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 05/05/2021] [Indexed: 11/13/2022]
Abstract
BACKGROUND Intraoperative tissue analysis and identification are critical to guide surgical procedures and improve patient outcomes. Here, we describe the clinical translation and evaluation of the MasSpec Pen technology for molecular analysis of in vivo and freshly excised tissues in the operating room (OR). METHODS An Orbitrap mass spectrometer equipped with a MasSpec Pen interface was installed in an OR. A "dual-path" MasSpec Pen interface was designed and programmed for the clinical studies with 2 parallel systems that facilitated the operation of the MasSpec Pen. The MasSpec Pen devices were autoclaved before each surgical procedure and were used by surgeons and surgical staff during 100 surgeries over a 12-month period. RESULTS Detection of mass spectral profiles from 715 in vivo and ex vivo analyses performed on thyroid, parathyroid, lymph node, breast, pancreatic, and bile duct tissues during parathyroidectomies, thyroidectomies, breast, and pancreatic neoplasia surgeries was achieved. The MasSpec Pen enabled gentle extraction and sensitive detection of various molecular species including small metabolites and lipids using a droplet of sterile water without causing apparent tissue damage. Notably, effective molecular analysis was achieved while no limitations to sequential histologic tissue analysis were identified and no device-related complications were reported for any of the patients. CONCLUSIONS This study shows that the MasSpec Pen system can be successfully incorporated into the OR, allowing direct detection of rich molecular profiles from tissues with a seconds-long turnaround time that could be used to inform surgical and clinical decisions without disrupting tissue analysis workflows.
Collapse
|
14
|
Andleeb F, Katta N, Gruslova A, Muralidharan B, Estrada A, McElroy AB, Ullah H, Brenner AJ, Milner TE. Differentiation of Brain Tumor Microvasculature From Normal Vessels Using Optical Coherence Angiography. Lasers Surg Med 2021; 53:1386-1394. [PMID: 34130353 DOI: 10.1002/lsm.23446] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 05/23/2021] [Accepted: 05/27/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND AND OBJECTIVES Despite rapid advances and discoveries in medical imaging, monitoring therapeutic efficacy for malignant gliomas and monitoring tumor vasculature remains problematic. The purpose of this study is to utilize optical coherence angiography for vasculature characterization inside and surrounding brain tumors in a murine xenograft brain tumor model. Features included in our analysis include fractional blood volume, vessel tortuosity, diameter, orientation, and directionality. STUDY DESIGN/MATERIALS AND METHODS In this study, five tumorous mice models at 4 weeks of age were imaged. Human glioblastoma cells were injected into the brain and allowed to grow for 4 weeks and then imaged using optical coherence tomography. RESULTS Results suggest that blood vessels outside the tumor contain a greater fractional blood volume as compared with vessels inside the tumor. Vessels inside the tumor are more tortuous as compared with those outside the tumor. Results indicate that vessels near the tumor margin are directed inward towards the tumor while normal vessels show a more random orientation. CONCLUSION Quantification of vascular microenvironments in brain gliomas can provide functional vascular parameters to aid various diagnostic and therapeutic studies. © 2021 Wiley Periodicals LLC.
Collapse
|
15
|
Halaney DL, Katta N, Fallah H, Aguilar G, Milner TE. Group Refractive Index of Nanocrystalline Yttria-Stabilized Zirconia Transparent Cranial Implants. Front Bioeng Biotechnol 2021; 9:619686. [PMID: 33869149 PMCID: PMC8044953 DOI: 10.3389/fbioe.2021.619686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 03/02/2021] [Indexed: 11/18/2022] Open
Abstract
Transparent “Window to the Brain” (WttB) cranial implants made from a biocompatible ceramic, nanocrystalline Yttria-Stabilized Zirconia (nc-YSZ), were recently reported. These reports demonstrated chronic brain imaging across the implants in mice using optical coherence tomography (OCT) and laser speckle imaging. However, optical properties of these transparent cranial implants are neither completely characterized nor completely understood. In this study, we measure optical properties of the implant using a swept source OCT system with a spectral range of 136 nm centered at 1,300 nm to characterize the group refractive index of the nc-YSZ window, over a narrow range of temperatures at which the implant may be used during imaging or therapy (20–43°C). Group refractive index was found to be 2.1–2.2 for OCT imaging over this temperature range. Chromatic dispersion for this spectral range was observed to vary over the sample, sometimes flipping signs between normal and anomalous dispersion. These properties of nc-YSZ should be considered when designing optical systems and procedures that propagate light through the window, and when interpreting OCT brain images acquired across the window.
Collapse
|
16
|
Nguyen HTM, Katta N, Widman JA, Takematsu E, Feng X, Torres-Hurtado SA, Betancourt T, Baker AB, Suggs LJ, Milner TE, Tunnell JW. Laser nanobubbles induce immunogenic cell death in breast cancer. NANOSCALE 2021; 13:3644-3653. [PMID: 33538275 PMCID: PMC8710258 DOI: 10.1039/d0nr06587k] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Recent advances in immunotherapy have highlighted a need for therapeutics that initiate immunogenic cell death in tumors to stimulate the body's immune response to cancer. This study examines whether laser-generated bubbles surrounding nanoparticles ("nanobubbles") induce an immunogenic response for cancer treatment. A single nanosecond laser pulse at 1064 nm generates micron-sized bubbles surrounding gold nanorods in the cytoplasm of breast cancer cells. Cell death occurred in cells treated with nanorods and irradiated, but not in cells with irradiation treatment alone. Cells treated with nanorods and irradiation had increased damage-associated molecular patterns (DAMPs), including increased expression of chaperone proteins human high mobility group box 1 (HMGB1), adenosine triphosphate (ATP), and heat shock protein 70 (HSP70). This enhanced expression of DAMPs led to the activation of dendritic cells. Overall, this treatment approach is a rapid and highly specific method to eradicate tumor cells with simultaneous immunogenic cell death signaling, showing potential as a combination strategy for immunotherapy.
Collapse
|
17
|
Keating MF, Zhang J, Feider CL, Retailleau S, Reid R, Antaris A, Hart B, Tan G, Milner TE, Miller K, Eberlin LS. Integrating the MasSpec Pen to the da Vinci Surgical System for In Vivo Tissue Analysis during a Robotic Assisted Porcine Surgery. Anal Chem 2020; 92:11535-11542. [PMID: 32786489 DOI: 10.1021/acs.analchem.0c02037] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Minimally invasive robotic-assisted surgeries have been increasingly used as a first-line of treatment for patients undergoing oncologic surgeries. In-situ tissue identification is critical to guide tissue resection and assist decision-making. Traditional intraoperative histopathologic analysis of frozen tissue sections can be time-consuming and present logistical challenges which interrupt surgical workflows. We report the development and implementation of a laparoscopic, drop-in version of the MasSpec Pen device integrated into the da Vinci Xi Surgical system for in vivo tissue analysis in a robotic-assisted porcine surgery. We evaluated the performance of the drop-in MasSpec Pen during surgery by introducing the device into the animal upper gastrointestinal system and performing in vivo analyses of the stomach and liver, including charred and bloody tissues after electrocauterization. The molecular profiles obtained included ions tentatively identified as metabolites and lipids typically observed with MasSpec Pen analysis, without causing observable tissue damage. Statistical classifiers built to distinguish porcine liver and stomach tissues using the in vivo data yielded an overall tissue identification accuracy of 98% (n = 53 analyses). The results provide evidence that the drop-in MasSpec Pen developed can be used to acquire mass spectra in vivo during a robotic-assisted surgery and might be used as an in vivo tissue assessment tool to help guide surgical resections and streamline surgical workflows.
Collapse
|
18
|
Gardner MR, Baruah V, Vargas G, Motamedi M, Milner TE, Rylander HG. Scattering Angle Resolved Optical Coherence Tomography Detects Early Changes in 3xTg Alzheimer's Disease Mouse Model. Transl Vis Sci Technol 2020; 9:18. [PMID: 32821490 PMCID: PMC7401921 DOI: 10.1167/tvst.9.5.18] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Accepted: 03/02/2020] [Indexed: 02/07/2023] Open
Abstract
Purpose Clinical intensity-based optical coherence tomographic retinal imaging is unable to resolve some of the earliest changes to Alzheimer's disease (AD) neurons. The aim of this pilot study was to demonstrate that scattering-angle-resolved optical coherence tomography (SAR-OCT), which is sensitive to changes in light scattering angle, is a candidate retinal imaging modality for early AD detection. SAR-OCT signal data may be sensitive to changes in intracellular constituent morphology that are not detectable with conventional OCT. Methods In this cross-sectional study, retinas of a triple transgenic mouse model of AD (3xTg-AD) were imaged alongside age-matched control mice (C57BL/6J) using SAR-OCT. A total of 32 mice (12 control, 20 3xTg-Ad) at four ages (10, 20, 30, and 45 weeks) were included in this cross-sectional study, and three retinal feature sets (scattering, thickness, and angiography) were examined between the disease and control groups. Results AD mice had significantly increased scattering diversity (lower SAR-OCT C parameter) at the earliest imaging time (10 weeks). Differences in the C parameter between AD and control mice were diminished at later times when both groups showed increased scattering diversity. AD mice have reduced retinal thickness compared to controls, particularly in central regions and superficial layers. No differences in vascular density or fractional blood volume between groups were detected. Conclusions SAR-OCT is sensitive to scattering angle changes in a 3xTg-AD mouse model and could provide early-stage biomarkers for neurodegenerative diseases such as AD. Translational Relevance Clinical OCT systems may be modified to record SAR-OCT images for non-invasive retinal diagnostic imaging of patients with neurodegenerative diseases such as AD.
Collapse
|
19
|
Milner TE. Introduction to Special Issue Honoring the Contributions of AJ Welch. Lasers Surg Med 2019; 52:195. [PMID: 31803952 DOI: 10.1002/lsm.23199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/22/2019] [Indexed: 11/11/2022]
|
20
|
Hoyt T, Feldman MD, Okutucu S, Lendel V, Marmagkiolis K, McIntosh V, Ates I, Kose G, Mego D, Paixao A, Iliescu C, Park J, Shaar M, Avci R, McElroy A, Dijkstra J, Milner TE, Cilingiroglu M. Assessment of Vascular Patency and Inflammation with Intravascular Optical Coherence Tomography in Patients with Superficial Femoral Artery Disease Treated with Zilver PTX Stents. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2019; 21:101-107. [PMID: 31395436 DOI: 10.1016/j.carrev.2019.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 06/15/2019] [Accepted: 07/02/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE Zilver PTX nitinol self-expanding drug-eluting stent with paclitaxel coating is effective for treatment of superficial femoral artery (SFA) disease. However, as with any stent, it induces a measure of vascular inflammatory response. The current clinical trial (NCT02734836) aimed to assess vascular patency, remodeling, and inflammatory markers with intravascular optical coherence tomography (OCT) in patients with SFA disease treated with Zilver PTX stents. METHODS Serial OCT examinations were performed in 13 patients at baseline and 12-month follow-up. Variables evaluated included neointimal area, luminal narrowing, thrombus area, stent expansion as well as measures of inflammation including, peri-strut low-intensity area (PLIA), macrophage arc, neovascularization, stent strut apposition and coverage. RESULTS Percentage of malapposed struts decreased from 10.3 ± 7.9% post-intervention to 1.1 ± 2.2% at 12-month follow-up, but one patient showed late-acquired stent malapposition (LASM). The percent of uncovered struts at follow-up was 3.0 ± 4.5%. Average expansion of stent cross-sectional area from baseline to follow-up was 35 ± 19%. The average neointimal area was 7.8 ± 3.8 mm2. Maximal luminal narrowing was 61.1 ± 25.0%, and average luminal narrowing was 35.4 ± 18.2%. Average peri-strut low-intensity area (PLIA) per strut was 0.017 ± 0.018 mm2. Average number of neovessels per mm of stent was 0.138 ± 0.181. Average macrophage angle per frame at follow-up was 7 ± 11°. Average thrombus area at follow-up was 0.0093 ± 0.0184 mm2. CONCLUSION At 12-month follow-up, OCT analysis of Zilver PTX stent shows outward remodeling and minimal neointimal growth, but evidence of inflammation including PLIA, neovessels, thrombus and macrophages. SUMMARY Thirteen patients with PAD had paclitaxel-coated stents implanted in their SFAs and were then imaged with OCT at baseline and 12-month follow-up. OCT proxy metrics of inflammation were quantified.
Collapse
|
21
|
Katta N, Estrada AD, McElroy AB, Gruslova A, Oglesby M, Cabe AG, Feldman MD, Fleming RYD, Brenner AJ, Milner TE. Laser brain cancer surgery in a xenograft model guided by optical coherence tomography. Am J Cancer Res 2019; 9:3555-3564. [PMID: 31281497 PMCID: PMC6587169 DOI: 10.7150/thno.31811] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Accepted: 04/24/2019] [Indexed: 12/16/2022] Open
Abstract
Higher precision surgical devices are needed for tumor resections near critical brain structures. The goal of this study is to demonstrate feasibility of a system capable of precise and bloodless tumor ablation. An image-guided laser surgical system is presented for excision of brain tumors in vivo in a murine xenograft model. The system combines optical coherence tomography (OCT) guidance with surgical lasers for high-precision tumor ablation (Er:YAG) and microcirculation coagulation (Thulium (Tm) fiber laser). Methods: A fluorescent human glioblastoma cell line was injected into mice and allowed to grow four weeks. Craniotomies were performed and tumors were imaged with confocal fluorescence microscopy. The mice were subsequently OCT imaged prior, during and after laser coagulation and/or ablation. The prior OCT images were used to compute three-dimensional tumor margin and angiography images, which guided the coagulation and ablation steps. Histology of the treated regions was then compared to post-treatment OCT images. Results: Tumor sizing based on OCT margin detection matched histology to within experimental error. Although fluorescence microscopy imaging showed the tumors were collocated with OCT imaging, margin assessment using confocal microscopy failed to see the extent of the tumor beyond ~ 250 µm in depth, as verified by OCT and histology. The two-laser approach to surgery utilizing Tm wavelength for coagulation and Er:YAG for ablation yielded bloodless resection of tumor regions with minimal residual damage as seen in histology. Conclusion: Precise and bloodless tumor resection under OCT image guidance is demonstrated in the murine xenograft brain cancer model. Tumor margins and vasculature are accurately made visible without need for exogenous contrast agents.
Collapse
|
22
|
Gardner MR, Rahman AS, Milner TE, Rylander HG. Scattering-Angle-Resolved Optical Coherence Tomography of a Hypoxic Mouse Retina Model. J Exp Neurosci 2019; 13:1179069519837564. [PMID: 30944521 PMCID: PMC6440039 DOI: 10.1177/1179069519837564] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 02/21/2019] [Indexed: 12/27/2022] Open
Abstract
Several studies have noted a correlation between retinal degeneration and traumatic encephalopathy (TE) making the retina a leading candidate for detection and assessment. Scattering-angle-resolved optical coherence tomography (SAR-OCT) is a candidate imaging modality to detect sub-resolution changes in retinal microstructure. SAR-OCT images of murine retinas that experience a hypoxic insult—euthanasia by isoflurane overdose—are presented. A total of 4 SAR-OCT measurement parameters are reported in 6 longitudinal experiments: blood flow volume fraction, total retinal thickness, reflectance index, and scattering angle. As each mouse expires, blood flow volume fraction decreases, total retinal thickness increases, reflectance index decreases, and scattering angle diversity increases. Contribution of the retinal vasculature to scattering angle diversity is discussed. Results of this study suggest the utility of SAR-OCT to measure TE using scattering angle diversity contrast in the retina.
Collapse
|
23
|
Hashemi M, Muralidharan B, Omidi M, Mohammadi J, Sefidbakht Y, Kima ES, Smyth HDC, Shalbaf M, Milner TE. Effect of size and chemical composition of graphene oxide nanoparticles on optical absorption cross-section. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-9. [PMID: 30156063 DOI: 10.1117/1.jbo.23.8.085007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2018] [Accepted: 08/03/2018] [Indexed: 06/08/2023]
Abstract
Photothermal therapy with various nanoparticles, as photothermal transducers, is a widely researched technique. A continuous wave (CW) laser is employed during this procedure. The therapeutic setup is slightly modified to measure the optical absorption cross-section of the graphene oxide (GO), by mitigating the effects of heat diffusion and light scattering. With an 808-nm CW laser setup modulated by a waveform modulation setup, the effect of nanoparticle size and composition of GO in water on optical absorption cross section is characterized.
Collapse
|
24
|
Zhang J, Rector J, Lin JQ, Young JH, Sans M, Katta N, Giese N, Yu W, Nagi C, Suliburk J, Liu J, Bensussan A, DeHoog RJ, Garza KY, Ludolph B, Sorace AG, Syed A, Zahedivash A, Milner TE, Eberlin LS. Nondestructive tissue analysis for ex vivo and in vivo cancer diagnosis using a handheld mass spectrometry system. Sci Transl Med 2018; 9:9/406/eaan3968. [PMID: 28878011 DOI: 10.1126/scitranslmed.aan3968] [Citation(s) in RCA: 234] [Impact Index Per Article: 39.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Accepted: 08/17/2017] [Indexed: 12/13/2022]
Abstract
Conventional methods for histopathologic tissue diagnosis are labor- and time-intensive and can delay decision-making during diagnostic and therapeutic procedures. We report the development of an automated and biocompatible handheld mass spectrometry device for rapid and nondestructive diagnosis of human cancer tissues. The device, named MasSpec Pen, enables controlled and automated delivery of a discrete water droplet to a tissue surface for efficient extraction of biomolecules. We used the MasSpec Pen for ex vivo molecular analysis of 20 human cancer thin tissue sections and 253 human patient tissue samples including normal and cancerous tissues from breast, lung, thyroid, and ovary. The mass spectra obtained presented rich molecular profiles characterized by a variety of potential cancer biomarkers identified as metabolites, lipids, and proteins. Statistical classifiers built from the histologically validated molecular database allowed cancer prediction with high sensitivity (96.4%), specificity (96.2%), and overall accuracy (96.3%), as well as prediction of benign and malignant thyroid tumors and different histologic subtypes of lung cancer. Notably, our classifier allowed accurate diagnosis of cancer in marginal tumor regions presenting mixed histologic composition. Last, we demonstrate that the MasSpec Pen is suited for in vivo cancer diagnosis during surgery performed in tumor-bearing mouse models, without causing any observable tissue harm or stress to the animal. Our results provide evidence that the MasSpec Pen could potentially be used as a clinical and intraoperative technology for ex vivo and in vivo cancer diagnosis.
Collapse
|
25
|
Gardner MR, Lewis A, Park J, McElroy AB, Estrada AD, Fish S, Beaman JJ, Milner TE. In situ process monitoring in selective laser sintering using optical coherence tomography. OPTICAL ENGINEERING (REDONDO BEACH, CALIF.) 2018; 57:041407. [PMID: 29576665 PMCID: PMC5859933 DOI: 10.1117/1.oe.57.4.041407] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Selective laser sintering (SLS) is an efficient process in additive manufacturing that enables rapid part production from computer-based designs. However, SLS is limited by its notable lack of in-situ process monitoring when compared to other manufacturing processes. We report the incorporation of optical coherence tomography into an SLS system in detail and demonstrate access to surface and sub-surface features. Video frame rate cross-sectional imaging reveals areas of sintering uniformity and areas of excessive heat error with high temporal resolution. We propose a set of image processing techniques for SLS process monitoring with OCT and report the limitations and obstacles for further OCT integration with SLS systems.
Collapse
|