1
|
Brown SD. Impact of introducing a new biological matrix into a validated bioanalytical method: Focus on matrix protein content. Biomed Chromatogr 2024; 38:e5884. [PMID: 38693051 DOI: 10.1002/bmc.5884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 04/05/2024] [Accepted: 04/09/2024] [Indexed: 05/03/2024]
Abstract
International guidance on bioanalytical method validation recommends the practice of partial validation when introducing a new matrix from the same species into a previously fully validated assay. Planning the partial validation protocol should include an evaluation of analyte chemistry, consideration of sample container materials, and a comparison of properties between the relevant biological matrices. Transition of a serum/plasma-validated bioanalytical method to analysis from a low-protein matrix, such as urine, cerebral spinal fluid, or oral fluid can result in inconsistent analyte recovery. The low recovery can potentially be mistaken for signal suppression or lack of drug stability and may be more pronounced in low-concentration or low-volume samples. In addition, adsorption and absorption interactions with containers may be exacerbated in low-protein matrices. Several possibilities exist for mitigating the impact of non-specific binding and low-protein matrices, including surfactants, bovine serum albumin, and β-cyclodextrin. Finally, higher matrix protein can facilitate analyte stability. Given all this, matrix protein content should not be overlooked when anticipating a partial bioanalytical method validation.
Collapse
|
2
|
Melén CM, Merrien M, Wasik AM, Sander B, Wahlin BE, Panagiotis G, Beck O. Δ 9-THC and CBD in Plasma, Oral Fluid, Exhaled Breath, and Urine from 23 Patients Administered Sativex. Cannabis Cannabinoid Res 2024; 9:e839-e846. [PMID: 37083482 DOI: 10.1089/can.2022.0179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023] Open
Abstract
Background: Detecting the presence of Δ9-THC and CBD is mainly done through venous blood sampling, but other methods are becoming available. Oromucosal administration of Δ9-THC and CBD is less studied than inhalation, but this mode of administration is growing. In this study, we analyze samples obtained through invasive and noninvasive methods in a cohort of patients given oromucosally administered Δ9-THC and CBD to gain understanding in the strengths and weaknesses of the various detection methods. Materials and Methods: Blood, oral fluid (OF), exhaled breath, and urine were collected at several time points from 23 cannabis-naive patients after receiving a single dose of Sativex®; dose ranges: Δ9-THC, 2.7-18.9 mg; CBD 2.5-17.5 mg. Detection of Δ9-THC and CBD was done using liquid chromatography-mass spectrometry methods. Results: Δ9-THC and CBD were present in plasma, OF, and exhaled breath in all 23 patients. The detection time of Δ9-THC and CBD in OF and exhaled breath was longer than in blood. Urine analysis detected the Δ9-THC carboxy metabolite (THC-COOH) up to 7 days after administration, also in a patient who received 8.1/7.5 mg Δ9-THC/CBD. Conclusion: Time to detection of cannabinoids in blood samples was shorter than in exhaled breath and OF. Relative ease of sample collection combined with high sensitivity makes OF and exhaled breath specimens a valuable addition when samples are handled correctly. Δ9-THC metabolites were detected for an unexpected long period of time in urine. EudraCT Number: 2014-005553-39. Date of registration, December 29, 2015.
Collapse
|
3
|
Derne AS, Pape E, Jouzeau JY, Kolodziej A, Gambier N, Scala-Bertola J. Immunological detection of hexahydrocannabinol (HHC) in oral fluid. Drug Test Anal 2024; 16:638-640. [PMID: 37916294 DOI: 10.1002/dta.3595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 10/11/2023] [Accepted: 10/17/2023] [Indexed: 11/03/2023]
|
4
|
Helander A, Johansson M, Villén T, Andersson A. Appearance of hexahydrocannabinols as recreational drugs and implications for cannabis drug testing - focus on HHC, HHC-P, HHC-O and HHC-H. Scand J Clin Lab Invest 2024; 84:125-132. [PMID: 38619215 DOI: 10.1080/00365513.2024.2340039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 02/13/2024] [Indexed: 04/16/2024]
Abstract
This study investigated the effects of hexahydrocannabinol (HHC) and other unclassified cannabinoids, which were recently introduced to the recreational drug market, on cannabis drug testing in urine and oral fluid samples. After the appearance of HHC in Sweden in 2022, the number of posts about HHC on an online drug discussion forum increased significantly in the spring of 2023, indicating increased interest and use. In parallel, the frequency of false positive screening tests for tetrahydrocannabinol (THC) in oral fluid, and for its carboxy metabolite (THC-COOH) in urine, rose from <2% to >10%. This suggested that HHC cross-reacted with the antibodies in the immunoassay screening, which was confirmed in spiking experiments with HHC, HHC-COOH, HHC acetate (HHC-O), hexahydrocannabihexol (HHC-H), hexahydrocannabiphorol (HHC-P), and THC-P. When HHC and HHC-P were classified as narcotics in Sweden on 11 July 2023, they disappeared from the online and street shops market and were replaced by other unregulated variants (e.g. HHC-O and THC-P). In urine samples submitted for routine cannabis drug testing, HHC-COOH concentrations up to 205 (mean 60, median 27) µg/L were observed. To conclude, cannabis drug testing cannot rely on results from immunoassay screening, as it cannot distinguish between different tetra- and hexahydrocannabinols, some being classified but others unregulated. The current trend for increased use of unregulated cannabinols will likely increase the proportion of positive cannabis screening results that need to be confirmed with mass spectrometric methods. However, the observed cross-reactivity also means a way to pick up use of new cannabinoids that otherwise risk going undetected.
Collapse
|
5
|
Grabenauer M, Vikingsson S, Olson RA, Lyons FE, Davis LS, Hayes ED, Flegel RR. Systematic web monitoring of drug test subversion strategies in the United States. Drug Test Anal 2024. [PMID: 38520174 DOI: 10.1002/dta.3671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 02/06/2024] [Accepted: 02/14/2024] [Indexed: 03/25/2024]
Abstract
As negative drug tests are frequently a condition for employment, some people who use drugs will try to subvert the testing. In this study, systematic web monitoring was used to investigate how drug test subversion is discussed online. Posts pertaining to drug test subversion were obtained from public websites and the dark web (n = 634, July-December 2021). Most information from public websites came from Twitter (65%), and 94% of dark web posts were from Reddit. The posts were manually coded to extract quantitative and qualitative information about drug test subversion tactics. Most posts discussed urine drug tests (85%), followed by hair (11%) and oral fluid (2%), and the most discussed drugs were marijuana (72%) and cocaine (7.3%). Urine drug test subversion mainly pertained to specimen substitution, with synthetic urine or urine from another person. Another strategy was to mask diluted urine by ingesting creatine. Urine adulteration was rarely discussed. Hair test subversion involved harsh treatments with products such as bleach, baking soda, and/or detergent. Hair removal was also discussed. Oral fluid test subversion focused on removing drugs from the oral cavity through vigorous brushing of teeth and tongue as well as the use of mouthwash, hydrogen peroxide, gum, and commercial detox products. This study highlights subversion strategies used by donors. Although little evidence was provided as to the effectiveness of these strategies, this information may help guide future studies and development of specimen validity testing to minimize the impact of drug test subversion attempts.
Collapse
|
6
|
Scherer JN, Vasconcelos M, Dalanhol CS, Govoni B, Dos Santos BP, Borges GR, de Gouveia GC, Viola PP, Carlson RLR, Martins AF, Costa JL, Huestis MA, Pechansky F. Reliability of roadside oral fluid testing devices for ∆ 9 -tetrahydrocannabinol (∆ 9 -THC) detection. Drug Test Anal 2024. [PMID: 38440942 DOI: 10.1002/dta.3669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/29/2024] [Accepted: 02/13/2024] [Indexed: 03/06/2024]
Abstract
Driving under the influence of cannabis (DUIC) is increasing worldwide, and cannabis is the most prevalent drug after alcohol in impaired driving cases, emphasizing the need for a reliable traffic enforcement strategy. ∆9 -tetrahydrocannabinol (THC) detection in oral fluid has great potential for identifying recent cannabis use; however, additional data are needed on the sensitivities, specificities, and efficiencies of different oral fluid devices for detecting cannabinoids at the roadside by police during routine traffic safety enforcement efforts. At the roadside, 8945 oral fluid THC screening tests were performed with four devices: AquilaScan®, Dräger DrugTest®, WipeAlyser Reader®, and Druglizer®. A total of 530 samples screened positive for THC (5.9%) and were analyzed by liquid chromatography-tandem mass spectrometry at multiple cutoff concentrations (2 ng/mL, 10 ng/mL, and manufacturers' recommended device cutoffs) to investigate device performance. Results varied substantially, with sensitivities of 0%-96.8%, specificities of 89.8%-98.5%, and efficiencies of 84.3%-97.8%. The Dräger DrugTest® outperformed the other devices with a 96.8% sensitivity, 97.1% specificity, and 97.0% efficiency at a 5-ng/mL LC-MS/MS confirmation cutoff. The WipeAlyser Reader® had good performance with a 91.4% sensitivity, 97.2% specificity, and 96.4% efficiency. AquilaScan® and Druglizer® had unacceptable performance for cannabinoid detection, highlighted by sensitivity <13%. The choice of roadside oral fluid testing device must offer good analytical performance for cannabinoids because of its high prevalence of use and impact on road safety.
Collapse
|
7
|
Suraev A, McCartney D, Kevin R, Gordon R, Grunstein RR, Hoyos CM, McGregor IS. Detection of Δ 9 -tetrahydrocannabinol (THC) in oral fluid using two point-of-collection testing devices following oral administration of a THC and cannabidiol containing oil. Drug Test Anal 2024. [PMID: 38414100 DOI: 10.1002/dta.3658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 01/17/2024] [Accepted: 01/30/2024] [Indexed: 02/29/2024]
Abstract
Point-of-collection testing (POCT) devices are widely used in roadside and workplace drug testing to identify recent cannabis use by measuring the presence of Δ9 -tetrahydrocannabinol (THC) in oral fluid (OF). However, the performance of POCT devices with oral medicinal cannabis products remains poorly described. In a randomised, double-blinded, crossover trial, adults with insomnia disorder (n = 20) received a single (2 mL) oral dose of oil containing 10 mg THC + 200 mg cannabidiol, or placebo, prior to sleep. Participants were tested with the Securetec DrugWipe® 5S (10 ng/mL THC cut-off) and Dräger DrugTest® 5000 (25 ng/mL THC cut-off) POCT devices at baseline (pre-treatment) and then at 0.5, 10, and 18 h post-treatment. An OF sample, taken at each time point, was also analysed using liquid chromatography-tandem mass spectrometry. Large individual variability in OF THC concentrations was observed 0.5 h post-treatment (range: 0-425 ng/mL; mean (SD) 48.7 (107.5) ng/mL). Both the Securetec DrugWipe® 5S and DrugTest® 5000 demonstrated poor sensitivity to THC at 0.5 h post-treatment (25% and 50%, respectively). At 10 and 18 h post-treatment, all participant OF THC concentrations were below screening cut-offs, and all test results were negative. These findings highlight the relatively poor sensitivity of both devices in detecting recent use of an oral medicinal cannabis product. They also suggest a low probability of obtaining a positive THC result the morning after ('one-off') use. Further research is required to establish the probability of obtaining a positive THC result with regular medicinal cannabis use.
Collapse
|
8
|
Trif C, Harpaz D, Eltzov E, Parcharoen Y, Pechyen C, Marks RS. Detection of Cannabinoids in Oral Fluid Specimens as the Preferred Biological Matrix for a Point-of-Care Biosensor Diagnostic Device. BIOSENSORS 2024; 14:126. [PMID: 38534233 DOI: 10.3390/bios14030126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/18/2024] [Accepted: 02/21/2024] [Indexed: 03/28/2024]
Abstract
An increasing number of countries have started to decriminalize or legalize the consumption of cannabis for recreational and medical purposes. The active ingredients in cannabis, termed cannabinoids, affect multiple functions in the human body, including coordination, motor skills, memory, response time to external stimuli, and even judgment. Cannabinoids are a unique class of terpeno-phenolic compounds, with 120 molecules discovered so far. There are certain situations when people under the influence of cannabis may be a risk to themselves or the public safety. Over the past two decades, there has been a growing research interest in detecting cannabinoids from various biological matrices. There is a need to develop a rapid, accurate, and reliable method of detecting cannabinoids in oral fluid as it can reveal the recent intake in comparison with urine specimens, which only show a history of consumption. Significant improvements are continuously made in the analytical formats of various technologies, mainly concerning improving their sensitivity, miniaturization, and making them more user-friendly. Additionally, sample collection and pretreatment have been extensively studied, and specific devices for collecting oral fluid specimens have been perfected to allow rapid and effective sample collection. This review presents the recent findings regarding the use of oral fluid specimens as the preferred biological matrix for cannabinoid detection in a point-of-care biosensor diagnostic device. A critical review is presented, discussing the findings from a collection of review and research articles, as well as publicly available data from companies that manufacture oral fluid screening devices. Firstly, the various conventional methods used to detect cannabinoids in biological matrices are presented. Secondly, the detection of cannabinoids using point-of-care biosensors is discussed, emphasizing oral fluid specimens. This review presents the current pressing technological challenges and highlights the gaps where new technological solutions can be implemented.
Collapse
|
9
|
Jacob-Nascimento LC, Portilho MM, Anjos RO, Moreira PSS, Stauber C, Weaver SC, Kitron U, Reis MG, Ribeiro GS. Detection of Chikungunya Virus RNA in Oral Fluid and Urine: An Alternative Approach to Diagnosis? Viruses 2024; 16:235. [PMID: 38400011 PMCID: PMC10891727 DOI: 10.3390/v16020235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/19/2024] [Accepted: 01/24/2024] [Indexed: 02/25/2024] Open
Abstract
To evaluate whether oral fluids (OF) and urine can serve as alternative, non-invasive samples to diagnose chikungunya virus (CHIKV) infection via RT-qPCR, we employed the same RNA extraction and RT-qPCR protocols on paired serum, OF and urine samples collected from 51 patients with chikungunya during the acute phase of the illness. Chikungunya patients were confirmed through RT-qPCR in acute-phase sera (N = 19), IgM seroconversion between acute- and convalescent-phase sera (N = 12), or IgM detection in acute-phase sera (N = 20). The controls included paired serum, OF and urine samples from patients with non-arbovirus acute febrile illness (N = 28) and RT-PCR-confirmed dengue (N = 16). Nine (47%) of the patients with positive RT-qPCR for CHIKV in sera and two (17%) of those with CHIKV infection confirmed solely via IgM seroconversion had OF positive for CHIKV in RT-qPCR. One (5%) patient with CHIKV infection confirmed via serum RT-qPCR was positive in the RT-qPCR performed on urine. None of the negative control group samples were positive. Although OF may serve as an alternative sample for diagnosing acute chikungunya in specific settings, a negative result cannot rule out an infection. Further research is needed to investigate whether OF and urine collected later in the disease course when serum becomes RT-qPCR-negative may be helpful in CHIKV diagnosis and surveillance, as well as to determine whether urine and OF pose any risk of CHIKV transmission.
Collapse
|
10
|
Metrik J, McCarthy DM. How research and policy can shape driving under the influence of cannabis. Addiction 2024; 119:208-210. [PMID: 37877315 PMCID: PMC11104562 DOI: 10.1111/add.16372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 10/03/2023] [Indexed: 10/26/2023]
|
11
|
Shelver WL, McGarvey AM, Holthusen JE, Young JM, Byrd CJ, Smith DJ. Comparison of immunoassay and LC-tandem mass spectrometry analyses of ractopamine in hog oral fluid. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2024; 41:162-174. [PMID: 38190266 DOI: 10.1080/19440049.2023.2300738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 12/26/2023] [Indexed: 01/10/2024]
Abstract
The accurate detection of ractopamine in food animals is crucial for marketing since some entities require animals or animal carcasses to be free of ractopamine residues. Field-based ractopamine screening tests that are rapid, sensitive, and capable of high-throughput are highly desirable to ensure that inadvertent exposure to ractopamine did not occur in animals marketed as animals that have not been fed ractopamine. An immunochemically based lateral flow assay was used to analyze oral fluids from hogs never exposed to ractopamine and from hogs that were presumed positives and results were confirmed using an enhanced sensitivity LC-MSMS method. We found that an immunochemically based lateral flow system having a working range of 2.5 to 15 ng mL-1 worked well as a screening assay with 1.7% false positive results in freshly collected hog oral fluids. Using ractopamine glucuronide standards and LC-MSMS, we determined that the false positive results were not due to the presence of ractopamine glucuronide metabolites in oral fluids.
Collapse
|
12
|
Cabarcos-Fernández P, Álvarez-Freire I, Rubio NC, Bermejo-Barrera AM, Moreda-Piñeiro A, Sánchez-Sellero I, Tabernero-Duque MJ. Evaluation of an Oral Fluid Collection Device and a Solid-Phase Extraction Method for the Determination of Coca Leaf Alkaloids by Gas Chromatography-Mass Spectrometry. Molecules 2024; 29:592. [PMID: 38338336 PMCID: PMC11154435 DOI: 10.3390/molecules29030592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/10/2024] [Accepted: 01/19/2024] [Indexed: 02/12/2024] Open
Abstract
Some South American countries have ancient traditions that may pose legal problems, such as the consumption of coca leaves, as this can provide positive results for cocaine use after the analysis of biological samples. For this reason, it is necessary to find specific markers that help differentiate legal from illegal consumption, such as tropacocaine, cinnamoylcocaine, and especially hygrine and cuscohygrine. In this work, two techniques for collecting biological samples are compared: the Quantisal® Oral Fluid collection device and passive drooling. Once the samples were collected, they were subjected to solid-phase extraction for subsequent injection into GC-MS. Different validation parameters included in international guides have been studied to evaluate whether the proposed method is valid for the defined purpose, placing special emphasis on the study of the matrix effect and little value on GC-MS analyses. With respect to this parameter, an increase in the signal was found for CUS and t-CIN, but it was not significant for the rest of the substances studied. The recoveries have varied significantly depending on the way of working, being higher when working with standardized areas. After carrying out work with the oral fluid samples collected from laboratory volunteers, the method was applied to two real samples. The results obtained support the need for further research to overcome certain limitations presented by the device.
Collapse
|
13
|
Goryński K, Sobczak Ł, Kołodziej D. Developing and Evaluating the Greenness of a Reliable, All-in-One Thin-Film Microextraction Protocol for Determining Fentanyl, Methadone, and Zolpidem in Plasma, Urine, and Oral Fluid. Molecules 2024; 29:335. [PMID: 38257248 PMCID: PMC10818652 DOI: 10.3390/molecules29020335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 12/26/2023] [Accepted: 01/05/2024] [Indexed: 01/24/2024] Open
Abstract
This paper proposes an all-in-one microextraction-based protocol capable of determining and quantifying fentanyl, methadone, and zolpidem in plasma, urine, and saliva at concentrations below those required by international regulatory organizations. A homemade thin-film microextraction device featuring an octyl-cyanopropyl stationary phase was coupled with LC-MS/MS. The proposed method was developed and validated according to FDA criteria, providing extraction efficiency values ranging from 26.7% to 76.2% with no significant matrix effects (2.6% to 15.5% signal suppression). The developed protocol provided low limits of quantification (mostly equal to 1 ng mL-1) and good reproducibility (intra- and inter-day RSDs of less than 9.6% and 12.0%, respectively) and accuracy (89% to 104% of the test concentration). An assessment of the protocol's environmental impact indicated that attention must be devoted to eliminating the use of toxic reagents and developing its capability for in situ sampling and in-field analysis using portable instruments. The proposed TFME-based protocol provides clinical laboratories with a versatile, one-step tool that enables the simultaneous monitoring of fentanyl, methadone, and zolpidem using the most popular biological matrices.
Collapse
|
14
|
Ryskina EA, Magsumova OA, Postnikov MA, Lobaeva TA, Ahmedzhanov BB, Shishparenok AN, Zhdanov DD. Effect of the Teeth Whitening Procedure on the Mineral Composition of Oral Fluid. Dent J (Basel) 2023; 12:9. [PMID: 38248217 PMCID: PMC10814888 DOI: 10.3390/dj12010009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/19/2023] [Accepted: 12/28/2023] [Indexed: 01/23/2024] Open
Abstract
The basis of modern tooth whitening systems is the use of a whitening gel, which usually contains hydrogen peroxide or carbamide peroxide. The study included 81 patients aged 22 to 35 years with a tooth color A2 and a darker color on the Vita Classic scale. The purpose of our research was to identify a new approach to whitening teeth to improve safety and gentleness. To perform this, we assessed the effect of the tooth whitening procedure on the mineral composition of the oral fluid. A new approach to the teeth whitening procedure was to use a mouth retractor and a tool for aspirating the whitening gel, which we developed. Before the procedure, a protective film-forming aerosol, which included sodium ascorbate, was applied. After the tooth whitening procedure, the enamel was remineralized with a sealing liquid for 14 days. The concentrations of calcium and phosphorus in the oral fluid were determined using a spectrophotometer with a set of reagents (Human). The results obtained indicate that the new approach to the teeth whitening procedure contributed to less pronounced changes in the concentrations of calcium (+29.07, p < 0.001) and phosphorus (-14%, p < 0.001) in the oral fluid immediately after the procedure and in combination with the standard procedure for teeth whitening; immediately after this procedure, the calcium concentration increased by 74.4% (p < 0.001), and the phosphorus concentration decreased by 23.07% (p < 0.001). The use of remineralizing agents led to a faster recovery of the initial levels of calcium and phosphorus in the oral fluid.
Collapse
|
15
|
Flaisher-Grinberg S. Poppy Seed Consumption and Oral Fluid Opioids Detection: A Classroom Demonstration of Psychopharmacological Concepts. JOURNAL OF UNDERGRADUATE NEUROSCIENCE EDUCATION : JUNE : A PUBLICATION OF FUN, FACULTY FOR UNDERGRADUATE NEUROSCIENCE 2023; 22:A37-A44. [PMID: 38322397 PMCID: PMC10768820 DOI: 10.59390/jwnq5957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 09/13/2023] [Accepted: 09/15/2023] [Indexed: 02/08/2024]
Abstract
Psychopharmacological concepts such as pharmacokinetics, pharmacodynamics and drug interactions can be difficult to illustrate within the college classroom. In this demonstration, students consume poppy seed-containing food items, assess opioid content in their oral fluid using commercial drug test kits, and relate the findings to learned materials, its real-life applications, and relevant societal implications. This demonstration can clarify processes such as drug absorption, distribution, metabolism, and excretion (ADME), broaden the review of information relevant to opioids mechanisms of action, and facilitate the discussion of topics such as drug abuse, dependence, and addiction, as well as drug development, testing, policy, and enforcement. Instructors can employ different experimental designs, create dose-dependent/timeline detection plots, or allow students to construct their own experiments, assessing possible mediators of opioid detection. The demonstration can also be utilized to discuss scientific myths, truths, data misinterpretation and misrepresentation. Several optional protocols are provided, required materials are indicated, and discussion points are suggested.
Collapse
|
16
|
Rosendo LM, Antunes M, Simão AY, Brinca AT, Catarro G, Pelixo R, Martinho J, Pires B, Soares S, Cascalheira JF, Passarinha L, Rosado T, Barroso M, Gallardo E. Sensors in the Detection of Abused Substances in Forensic Contexts: A Comprehensive Review. MICROMACHINES 2023; 14:2249. [PMID: 38138418 PMCID: PMC10745465 DOI: 10.3390/mi14122249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 12/10/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
Forensic toxicology plays a pivotal role in elucidating the presence of drugs of abuse in both biological and solid samples, thereby aiding criminal investigations and public health initiatives. This review article explores the significance of sensor technologies in this field, focusing on diverse applications and their impact on the determination of drug abuse markers. This manuscript intends to review the transformative role of portable sensor technologies in detecting drugs of abuse in various samples. They offer precise, efficient, and real-time detection capabilities in both biological samples and solid substances. These sensors have become indispensable tools, with particular applications in various scenarios, including traffic stops, crime scenes, and workplace drug testing. The integration of portable sensor technologies in forensic toxicology is a remarkable advancement in the field. It has not only improved the speed and accuracy of drug abuse detection but has also extended the reach of forensic toxicology, making it more accessible and versatile. These advancements continue to shape forensic toxicology, ensuring swift, precise, and reliable results in criminal investigations and public health endeavours.
Collapse
|
17
|
Panyasing Y, Gimenez-Lirola L, Thanawongnuwech R, Prakobsuk P, Kawilaphan Y, Kittawornrat A, Cheng TY, Zimmerman J. Performance of a Differentiation of Infected from Vaccinated Animals (DIVA) Classical Swine Fever Virus (CSFV) Serum and Oral Fluid Erns Antibody AlphaLISA Assay. Animals (Basel) 2023; 13:3802. [PMID: 38136839 PMCID: PMC10740410 DOI: 10.3390/ani13243802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 12/06/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023] Open
Abstract
Classical swine fever virus (CSFV) is an OIE-listed disease that requires effective surveillance tools for its detection and control. The aim of this study was to develop and evaluate the diagnostic performance of a novel CSFV Erns IgG AlphaLISA for both serum and oral fluid specimens that would likewise be compatible with the use of CSFV E2 DIVA vaccines. Test performance was evaluated using a panel of well-characterized serum (n = 760) and individual (n = 528) or pen-based (n = 30) oral fluid samples from four groups of animals: (1) negative controls (n = 60 pigs); (2) inoculated with ALD strain wild-type CSFV (n = 30 pigs); (3) vaccinated with LOM strain live CSFV vaccine (n = 30 pigs); and (4) vaccinated with live CSFV marker vaccine on commercial farms (n = 120 pigs). At a cutoff of S/P ≥ 0.7, the aggregate estimated diagnostic sensitivities and specificities of the assay were, respectively, 97.4% (95% CI 95.9%, 98.3%) and 100% for serum and 95.4% (95% CI 92.9%, 97.0%) and 100% for oral fluid. The Erns IgG antibody AlphaLISA combined DIVA capability with solid diagnostic performance, rapid turnaround, ease of use, and compatibility with both serum and oral fluid specimens.
Collapse
|
18
|
Qi S, He Q, Zhang Z, Chen H, Giménez-Lirola L, Yuan F, Bei W. Detection of Porcine Circovirus Type 3 in Serum, Semen, Oral Fluid, and Preputial Fluid Samples of Boars. Vet Sci 2023; 10:689. [PMID: 38133240 PMCID: PMC10747573 DOI: 10.3390/vetsci10120689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 11/17/2023] [Accepted: 12/01/2023] [Indexed: 12/23/2023] Open
Abstract
Porcine circovirus type 3 (PCV3) is commonly associated with clinical symptoms such as porcine dermatitis and nephropathy syndrome (PDNS)-like lesions, respiratory signs, and reproductive disorders. This study aimed to investigate the epidemiology of PCV3 in a boar stud. The objectives were to detect PCV3 in semen, as well as matched serum, oral fluid, and preputial fluid samples from adult boars using quantitative polymerase chain reaction (qPCR), analyze PCV3-IgG antibody data, and genetically characterize a positive sample. A total of 112 samples from 28 boars were collected from a large-scale pig farm in Guangxi, China. The qPCR results showed that the PCV3 DNA was not detected in semen, with a positive rate of 0% (0/28), while it was detected in serum (3.57%-1/28), oral fluid (64.28%-18/28), and preputial fluid (46.4%-13/28). The seropositivity rate of PCV3-IgG in serum was 82.14% (23/28) according to the indirect enzyme-linked immunosorbent serologic assay (ELISA) results. Phylogenetic analysis revealed that one of the PCV3 isolates belonged to the PCV3c clades. This is the first report of PCV3 detection in preputial fluid from boars. The results suggest that PCV3 is transmitted among boars on pig farms and exhibits epidemic characteristics.
Collapse
|
19
|
Räisänen IT, Aji NRAS, Sakellari D, Grigoriadis A, Rantala I, Pätilä T, Heikkilä P, Gupta S, Sorsa T. Active Matrix Metalloproteinase-8 (aMMP-8) Versus Total MMP-8 in Periodontal and Peri-Implant Disease Point-of-Care Diagnostics. Biomedicines 2023; 11:2885. [PMID: 38001886 PMCID: PMC10669684 DOI: 10.3390/biomedicines11112885] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/13/2023] [Accepted: 10/18/2023] [Indexed: 11/26/2023] Open
Abstract
Active matrix metalloproteinase-8 (aMMP-8) is a promising biomarker candidate for the modern periodontal and peri-implant disease diagnostics utilizing the chairside/point-of-care oral fluid technologies. These rapid biomarker analysis technologies utilize gingival crevicular fluid (GCF), peri-implant sulcular fluid (PISF), or mouth rinse as the oral fluid matrices that can be collected patient-friendly and non-invasively without causing bacteremia. aMMP-8, but not total or latent proMMP-8, has been shown to be a relevant biomarker to be implemented to the latest 2017 classification system of periodontitis and peri-implantitis. Thus, aMMP-8 point-of-care-testing (POCT)-but not total or latent proMMP-8-can be conveniently used as an adjunctive and preventive diagnostic tool to identify and screen the developing and ongoing periodontal and peri-implant breakdown and disease as well as predict its episodic progression. Similarly, aMMP-8 POCT provides an important tool to monitor the treatment effect of these diseases, but also other diseases such as head and neck cancer, where it can identify and predict the rapid tissue destructive oral side-effects during and after the radiotherapy. Additionally, recent studies support aMMP-8 POCT benefitting the identification of periodontitis and diabetes as the escalating risk diseases for COVID-19 infection. Overall, aMMP-8 POCT has launched a new clinical field in oral medicine and dentistry, i.e., oral clinical chemistry.
Collapse
|
20
|
Carella E, Caruso C, Moreno A, Di Blasio A, Oberto F, Vitale N, Masoero L. Meat Juice and Oral Fluid as Alternatives to Serum for Aujeszky Disease Monitoring in Pigs. Microorganisms 2023; 11:2418. [PMID: 37894076 PMCID: PMC10609404 DOI: 10.3390/microorganisms11102418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 09/22/2023] [Accepted: 09/25/2023] [Indexed: 10/29/2023] Open
Abstract
Aujeszky Disease Virus (ADV) is a double-stranded DNA virus with a lipoprotein envelope. The natural hosts of the infection are Suidae, but the virus can infect many other mammals. The gold-standard method identified by the WOAH for the diagnosis of Aujeszky disease is the ELISA method. The objective of this study was to compare the performance of meat juice and oral fluid matrices using a commercial ELISA kit designed for serum. A total of 80 blood and oral fluid samples were collected from four pig farms selected for this study. Diaphragm muscle samples of about 100 g and blood samples were collected from 213 animals at the abattoir. These biological matrices were collected from the same animals and tested using a competitive ELISA kit to detect antibodies against ADV. The relative accuracy of the meat juice compared to that of the serum was 96.7% (95% CI: 93.3-98.7%), with 206 correct results out of 213. The relative accuracy of the oral fluid compared to that of the serum was 61.3% (95% CI: 49.7-71.9%), with 58 correct results out of 80. Meat juice has a better combination of sensitivity and specificity than oral fluid. The usage of meat juice in routine diagnostic examinations could be achieved after further investigations to optimize the procedure.
Collapse
|
21
|
Lebret A, Normand V, Berton P, Nicolazo T, Teixeira Costa C, Chevance C, Brissonnier M, Boulbria G. Alternative Samples for Porcine Reproductive and Respiratory Syndrome Surveillance in an Endemic PRRSV-1-Infected Breeding Herd: A Descriptive Study. Vet Sci 2023; 10:558. [PMID: 37756080 PMCID: PMC10537479 DOI: 10.3390/vetsci10090558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 08/28/2023] [Accepted: 09/01/2023] [Indexed: 09/28/2023] Open
Abstract
Knowing porcine reproductive and respiratory syndrome (PRRS) status is essential for designing herd management protocols. For this, weaning-age pigs are a key subpopulation. Recently, different alternatives to blood sampling have been introduced because they are easier, welfare-friendly and cost-saving tools. Moreover, most of them allow the testing of more animals and seem to be more sensitive in low-prevalence scenarios. However, these studies were implemented mainly in PRRSV-2-infected herds. The first objective of our study was to compare the rate of detection of PRRSV-1 by RT-qPCR in individual serum samples, family oral fluid samples (FOF) and udder wipes (UW) collected the day before weaning. The second objective was to evaluate the suitability of pooling. The study was performed on a 210-sow farrow-to-finish farm which was PRRSV-1 infected and unstable. A total of 119 litters were sampled. The rate of detection of PRRSV-1 in blood samples, FOF and UW was 10.9%, 7.6% and 0.8%, respectively. The agreement between sera and FOF was almost perfect even if the detection capacity of sera was numerically superior to FOF. The Ct values of positive sera were statistically lower than those of FOF. Two modalities of pooling (1:3 and 1:5) were tested for sera and FOF. For sera, both modalities did not impact the PRRSV-1 status either at the litter level or at the batch one. On the other hand, whatever the modality (pooled by 3 or 5), most of the pools of FOF gave negative results, misclassifying many litters and batches.
Collapse
|
22
|
Armenta-Leyva B, Munguía-Ramírez B, Giménez-Lirola LG, Lin X, Ye F, Zimmerman J. Critical evaluation of strategies to achieve direct real-time PCR detection of swine pathogens in oral fluids. J Vet Diagn Invest 2023; 35:521-527. [PMID: 37337714 PMCID: PMC10467463 DOI: 10.1177/10406387231182102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/21/2023] Open
Abstract
Based on publications reporting improvements in real-time PCR (rtPCR) performance, we compared protocols based on heat treatment or dilution followed by direct rtPCR to standard extraction and amplification methods for the detection of porcine reproductive and respiratory syndrome virus (PRRSV), influenza A virus (IAV), porcine epidemic diarrhea virus (PEDV), or Mycoplasma hyopneumoniae (MHP) in swine oral fluids (OFs). In part A, we subjected aliquots of positive OF samples to 1 of 4 protocols: protocol 1: heat (95°C × 30 min) followed by direct rtPCR; protocol 2: heat and cool (25°C × 20 min) followed by direct rtPCR; protocol 3: heat, cool, extraction, and rtPCR; protocol 4 (control): extraction and then rtPCR. In part B, positive OF samples were split into 3, diluted (D1 = 1:2 with Tris-borate-EDTA (TBE); D2 = 1:2 with negative OF; D3 = not diluted), and then tested by rtPCR using the best-performing protocol from part A (protocol 4). In part A, with occasional exceptions, heat treatment resulted in marked reduction in the detection of target and internal sample control (ISC) nucleic acids. In part B, sample dilution with TBE or OF produced no improvement in the detection of targets and ISCs. Thus, standard extraction and amplification methods provided superior detection of PRRSV, IAV, PEDV, and MHP nucleic acids in OFs.
Collapse
|
23
|
Harper CE, Mata DC, Lee D. The impact of fentanyl on DUIDs and traffic fatalities: Blood and oral fluid data. J Forensic Sci 2023; 68:1686-1697. [PMID: 37477181 DOI: 10.1111/1556-4029.15334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 06/28/2023] [Accepted: 07/03/2023] [Indexed: 07/22/2023]
Abstract
Fentanyl has emerged as the most prolific drug in the ongoing opioid epidemic and has greatly impacted traffic safety in recent years. This study aimed to evaluate fentanyl prevalence and concentrations in blood and oral fluid in driving under the influence of drugs (DUID) cases in three different regions (i.e., Alabama, Orange County, CA, and Houston, TX) from 2017 to 2022. Furthermore, traffic fatalities were evaluated for Alabama and Orange County, CA. Fentanyl positivity in DUID and traffic fatalities increased for most years in this study. In Alabama, the prevalence of fentanyl DUID cases increased 4-fold in 2022 compared to 2017. Orange County's increase from 2017 to 2022 was 14-fold. In Houston, the increase was approximately 2-fold from 2019 to 2022. The greatest increase for all laboratories coincided with the start of the COVID-19 pandemic. In 2022, the median fentanyl DUID blood concentrations were 4.7, 11, and 4.7 ng/mL in Alabama, Orange County, and Houston, respectively. Most fentanyl cases were polydrug cases (≥90%). Methamphetamine, THC, and alprazolam were the most frequently detected drugs in combination with fentanyl. Alabama has collected oral fluid and blood in DUID cases since 2018. The detection of fentanyl in oral fluid was comparable to blood. However, 59% and 8.7% of fentanyl-positive cases had concentrations of >20 ng/mL in oral fluid and blood, respectively. Therefore, oral fluid as an alternative or supplemental specimen to blood is an attractive approach for fentanyl in DUID cases. This study contributes to understanding recent fentanyl trends and their impact on traffic safety.
Collapse
|
24
|
Munguía-Ramírez B, Armenta-Leyva B, Henao-Díaz A, Cheng TY, Zhang J, Rawal G, Ye F, Giménez-Lirola L, Zimmerman JJ. Effect of extrinsic factors on the detection of PRRSV and a porcine-specific internal sample control in serum, oral fluid, and fecal specimens tested by RT-rtPCR. J Vet Diagn Invest 2023; 35:374-383. [PMID: 37166086 PMCID: PMC10331379 DOI: 10.1177/10406387231174556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/12/2023] Open
Abstract
We characterized the effect of 1) temperature × time, 2) freeze-thaw cycles, and 3) high porcine reproductive and respiratory syndrome virus (PRRSV) RNA concentrations on the detection of PRRSV and a porcine-specific internal sample control (ISC) in serum, oral fluid, and fecal samples using a commercial PRRSV RT-rtPCR assay (Idexx). In study 1, the effect of temperature × time on PRRSV and ISC detection was shown to be specimen dependent. In serum stored at 4, 10, or 20°C, PRRSV detection was consistent for up to 168 h, but storage at 30°C reduced detectable PRRSV RNA. ISC RNA was stable in serum held at 4 and 10°C, but not at 20 and 30°C. In contrast, PRRSV and ISC RNAs in oral fluid and fecal samples continuously decreased at all temperature × time treatments. Based on these data, serum samples should be stored at ≤ 20°C to optimize PRRSV RNA detection. Oral fluid and fecal samples should be frozen in a non-self-defrosting freezer until tested. In study 2, freeze-thaw cycles had little impact on PRRSV and ISC detection, but more so in oral fluids than serum or fecal samples. Thus, freeze-thaw cycles in oral fluids should be minimized before RT-rtPCR testing. In study 3, the ISC was not affected by high concentrations of PRRSV RNA in serum, oral fluid, or fecal samples. It should not be assumed that data from our PRRSV study are applicable to other pathogens; additional pathogen-specific studies are required.
Collapse
|
25
|
Oliveira GM, Dionísio TJ, Siqueira-Sandrin VS, Ferrari LADL, Colombini-Ishikiriama BL, Faria FAC, Santos CF, Calvo AM. Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5'-Carboxymeloxicam in Oral Fluid Samples. Metabolites 2023; 13:755. [PMID: 37367912 DOI: 10.3390/metabo13060755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/12/2023] [Accepted: 06/13/2023] [Indexed: 06/28/2023] Open
Abstract
A sensitive, selective and particularly fast method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of meloxicam and its main metabolite, 5'-carboxymeloxicam, in oral fluid samples. Meloxicam and its major metabolite were separated using a Shim-Pack XR-ODS 75 L × 2.0 column and C18 pre-column at 40 °C using a mixture of methanol and 10 mM ammonium acetate (80:20, v/v) with an injection flow rate of 0.3 mL/min. The total time of the analytical run was 5 min. Sixteen volunteers had oral fluid samples collected sequentially before and after taking a meloxicam tablet (15 mg) for up to 96 h. With the concentrations obtained, the pharmacokinetic parameters were determined using the Phoenix WinNonlin software. The parameters evaluated for meloxicam and 5'-carboxymeloxicam in the oral fluid samples showed linearity, accuracy, precision, medium-quality control (MQC-78.12 ng/mL), high-quality control (HQC-156.25 ng/mL), lower limits of quantification (LLOQ-0.6103 ng/mL), low-quality control (LQC-2.44 ng/mL), stability and dilution. Prostaglandin E2 (PGE2) was also detected and quantified in the oral fluid samples, demonstrating the possibility of a pharmacokinetic/pharmacodynamic (PK/PD) study with this methodology. All the parameters evaluated in the validation of the methodology in the oral fluid samples proved to be stable and within the possible variations in each of the described parameters. Through the data presented, the possibility of a PK/PD study was demonstrated, detecting and quantifying meloxicam, its main metabolite and PGE2 in oral fluid samples using LC-MS/MS.
Collapse
|