1
|
Tang HT, Nörz D, Grunwald M, Giersch K, Pfefferle S, Fischer N, Aepfelbacher M, Rohde H, Lütgehetmann M. Analytical and clinical validation of a novel, laboratory-developed, modular multiplex-PCR panel for fully automated high-throughput detection of 16 respiratory viruses. J Clin Virol 2024; 173:105693. [PMID: 38820916 DOI: 10.1016/j.jcv.2024.105693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 05/10/2024] [Accepted: 05/13/2024] [Indexed: 06/02/2024]
Abstract
BACKGROUND Viral respiratory Infections pose a health risk, especially to vulnerable patient populations. Effective testing programs can detect and differentiate these infections at an early stage, which is particularly important for high-risk clinical departments. The objective of this study was to develop and validate a multiplex PCR-panel for 16 different respiratory viruses on a fully-automated high-throughput platform. METHODS Three multiplex-PCR assays were designed to run on the cobas5800/6800/8800 systems, consolidating 16 viral targets: RESP1: SARS-CoV-2, influenza-A/B, RSV; RESP2: hMPV, hBoV, hAdV, rhino-/ENV; RESP3: HPIV-1-4, hCoV-229E, hCoV-NL63, hCoV-OC43, hCoV-HKU1. Analytic performance was evaluated using digital-PCR based standards and international reference material. Clinical performance was determined by comparing results from clinical samples with reference assays. RESULTS Analytical sensitivity (i.e. lower limit of detection (LoD), 95 % probability of detection) was determined as follows: SARS-CoV-2: 29.3 IU/ml, influenza-A: 179.9 cp/ml, influenza-B: 333.9 cp/ml and RSV: 283.1 cp/ml. LoDs of other pathogens ranged between 9.4 cp/ml (hCoV-NL63) and 21,419 cp/ml (HPIV-2). Linearity was verified over 4-7 log-steps with pooled standard differentials (SD) ranging between 0.18-0.70ct. Inter-/intra-run variability (precision) was assessed for all targets over 3 days. SDs ranged between 0.13-0.74ct. Positive agreement in clinical samples was 99.4 % and 95 % for SARS-CoV-2 and influenza-A respectively. Other targets were in the 80-100 % range. Negative agreement varied between 96.3-100 %. DISCUSSION Lab-developed tests are a key factor for effective clinical diagnostics. The multiplex panel presented in this study demonstrated high performance and provides an easily scalable high-throughput solution for respiratory virus testing, e.g. for testing in high-risk patient populations.
Collapse
|
2
|
Lee C, Lim Y, Saintine D, Babady NE. Analytical and clinical evaluation of the cobas Epstein-Barr virus test at a tertiary care cancer hospital. J Clin Virol 2024; 173:105680. [PMID: 38728796 DOI: 10.1016/j.jcv.2024.105680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2024] [Revised: 04/18/2024] [Accepted: 04/28/2024] [Indexed: 05/12/2024]
Abstract
BACKGROUND Epstein-Barr Virus (EBV) viral loads in hematopoietic stem cell transplant (HSCT) recipients are typically monitored using quantitative molecular assays. The Cobas EBV test (Roche Molecular, Pleasanton, CA) has recently been FDA-cleared for the monitoring of EBV viral loads in plasma samples of transplant patients. In this study, we compared the viral loads obtained by a laboratory-developed test (EBV LDT) using Altona Analyte specific reagents (ASR) to those obtained on the Cobas EBV test. METHODS The analytical performance of the assay was established using the EBV verification panel from Exact Diagnostics and the EBV ATCC strain B95-8. The clinical evaluation was performed using 343 plasma samples initially tested on the EBV LDT. RESULTS The analytical sensitivity (<18.8 IU/mL), precision (SD < 0.17 log) and linear range (35.0 IU/mL to 1E + 08 IU/mL) of the Cobas EBV assay established by the manufacturers were confirmed. The strength of the qualitative agreement was substantial between the cobas EBV and the EBV LDT (85.6 %; κ = 0.71) and almost perfect when discordant results were resolved (96.4 %; κ = 0.93). The quantitative agreement was moderate (82.9 %; κ = 0.53) with the viral load obtained on the Cobas EBV test being lower across the linear range of the two tests (mean log difference of 1.0). While the absolute values of the viral loads were markedly different, the overall trends observed in patients with multiple consecutive results were similar between the two tests. CONCLUSIONS The Cobas EBV test provides an accurate and valid, in vitro diagnostic (IVD) option for monitoring of EBV viral loads in transplant patients and should provide an opportunity for increased standardization and commutability of tests results across laboratories.
Collapse
|
3
|
Wang C, Forsman LD, Wang S, Wang S, Shao G, Xiong H, Bao Z, Hu Y. The diagnostic performance of GeneXpert MTB/RIF in tuberculosis meningitis: A multicentre accuracy study. Diagn Microbiol Infect Dis 2024; 109:116277. [PMID: 38677052 DOI: 10.1016/j.diagmicrobio.2024.116277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 01/10/2024] [Accepted: 03/18/2024] [Indexed: 04/29/2024]
Abstract
OBJECTIVES To evaluate the performance of GeneXpert MTB/RIF (Xpert) for tuberculous meningitis (TBM) and to identify additional indicators to improve diagnostic accuracy. METHODS An accuracy study was conducted. During 2011-2019, 243 TBM with 140 non-TBM in three TB-designated facilities in China were enrolled. Microbiological evidence of M tuberculosis (Mtb) in CSF was used as the reference. Additional indicators were identified by Boosted-Classification and Regression Tree (CART), the improvement of diagnostic performance was evaluated by ROC. RESULTS The diagnostic sensitivity of Xpert was 71.1 % for definite TBM, and 5.5 % for probable/possible TBM. The positive rate of Xpert was improved with cerebrospinal fluid (CSF) increasing volume and was associated with CSF color (yellow). The additional indicators obtained by CART were CSF lactate and glucose and increased the sensitivity to 96.1 % (definite TBM) and 84.6 % (probable/possible TBM). CONCLUSIONS The diagnostic performance of Xpert was satisfactory in definite TBM and would significantly be improved by the additional use of CSF lactate and glucose.
Collapse
|
4
|
Kostera J, Hubbard M, Jackson D, Liesman RM. Evaluation of Alinity m CMV assay performance for detecting CMV in plasma, cerebrospinal fluid, and bronchoalveolar lavage specimens. Diagn Microbiol Infect Dis 2024; 109:116301. [PMID: 38723453 DOI: 10.1016/j.diagmicrobio.2024.116301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 03/28/2024] [Accepted: 04/09/2024] [Indexed: 05/28/2024]
Abstract
Accurate detection and quantification of cytomegalovirus (CMV) is crucial to preventing adverse outcomes in immunocompromised individuals. Current assays were developed for use with plasma specimens, but CMV may be present in bronchoalveolar lavage (BAL) fluid and cerebrospinal fluid (CSF). We evaluated the performance of the Abbott Alinity m CMV assay compared to the Abbott RealTime CMV assay for quantification of CMV in plasma, BAL, and CSF specimens. To evaluate clinical performance, 190 plasma, 78 BAL, and 20 CSF specimens were tested with the Alinity m assay and compared to the RealTime assay. The Alinity m CMV assay showed high precision (SD <0.01 to 0.13) for all 3 specimen types. Clincal plasma and BAL specimens with quantifiable CMV DNA demonstrated strong correlation to RealTime CMV assay results (r2 = 0.9779 for plasma, r2 = 0.9373 for BAL). The Alinity m CMV assay may be useful for quantification of CMV in plasma, BAL, and CSF specimens.
Collapse
|
5
|
Margulis M, Rohana H, Erster O, Mandelboim M, Biber A, Schwartz E, Peretz A, Danielli A. Highly sensitive extraction-free saliva-based molecular assay for rapid diagnosis of SARS-CoV-2. J Clin Microbiol 2024; 62:e0060024. [PMID: 38785448 DOI: 10.1128/jcm.00600-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Accepted: 04/28/2024] [Indexed: 05/25/2024] Open
Abstract
The COVID-19 pandemic highlighted the necessity of fast, sensitive, and efficient methods to test large populations for respiratory viruses. The "gold standard" molecular assays for detecting respiratory viruses, such as quantitative polymerase chain reaction (qPCR) and reverse transcription qPCR (RT-qPCR), rely on invasive swab samples and require time-consuming and labor-intensive extraction processes. Moreover, the turnaround time for RT-qPCR-based assays is too lengthy for rapid screening. Extraction-free saliva-based methods provide a non-invasive sampling process with a fast turnaround time and are suitable for high-throughput applications. However, when used with a standard RT-qPCR system, the absence of extraction significantly reduces the assays' sensitivity. Here, using a novel optical modulation biosensing (OMB) platform, we developed a rapid and highly sensitive extraction-free saliva-based molecular assay. We blindly tested 364 paired nasopharyngeal swabs and saliva samples from suspected SARS-CoV-2 cases in Israel. Compared with the gold standard swab-based RT-qPCR assay, the sensitivity of the extraction-free saliva-based OMB assay is 90.7%, much higher than the sensitivity of extraction-free saliva-based RT-qPCR assay (77.8%) with similar specificity (95.3% and 97.6%, respectively). Moreover, out of 12 samples identified by the OMB-based assay as positive, 8 samples were collected from hospitalized patients in a COVID-19 ward and were verified to be SARS-CoV-2-positive upon admission, indicating that the actual clinical sensitivity and specificity of the OMB assay are higher. Considering its user-friendly saliva-based protocol, short and cost-effective extraction-free process, and high clinical accuracy, the OMB-based molecular assay is very suitable for high-throughput testing of large populations for respiratory viruses. IMPORTANCE Three years after the SARS-CoV-2 outbreak, there are no molecular tests that combine low-cost and straightforward sample preparation, effective sample handling, minimal reagent and disposable requirements, high sensitivity, and high throughput required for mass screening. Existing rapid molecular techniques typically sacrifice certain requirements to meet others. Yet, localized outbreaks of novel viral diseases happen daily in different parts of the world. In this context, respiratory diseases are of specific importance, as they are frequently airborne and highly contagious, with the potential for a rapid global spread. The widely accepted opinion is that another pandemic is just a question of time. To ensure that the containment efforts for the upcoming "disease X" are successful, introducing rapid, high-throughput, and highly sensitive diagnostic methods for detecting and identifying pathogens is critical. A few months into the pandemic, saliva was suggested as a diagnostic matrix for SARS-CoV-2 detection. The collection of saliva does not require swabs and is minimally invasive. In particular, extraction-free saliva-based assays require fewer reagents and disposables, and therefore are faster and cheaper, offering an appealing alternative for low-income countries. Unfortunately, current extraction-free saliva-based detection methods, such as direct RT-qPCR or isothermal amplification, have either low sensitivity or low throughput. Therefore, we believe that the presented highly sensitive ht-OMBi platform and the extraction-free saliva-based molecular assay can become an essential tool in the infectious disease monitoring toolbox.
Collapse
|
6
|
Mourik K, Sidorov I, Carbo EC, van der Meer D, Boot A, Kroes ACM, Claas ECJ, Boers SA, de Vries JJC. Comparison of the performance of two targeted metagenomic virus capture probe-based methods using reference control materials and clinical samples. J Clin Microbiol 2024; 62:e0034524. [PMID: 38757981 DOI: 10.1128/jcm.00345-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Accepted: 04/05/2024] [Indexed: 05/18/2024] Open
Abstract
Viral enrichment by probe hybridization has been reported to significantly increase the sensitivity of viral metagenomics. This study compares the analytical performance of two targeted metagenomic virus capture probe-based methods: (i) SeqCap EZ HyperCap by Roche (ViroCap) and (ii) Twist Comprehensive Viral Research Panel workflow, for diagnostic use. Sensitivity, specificity, and limit of detection were analyzed using 25 synthetic viral sequences spiked in increasing proportions of human background DNA, eight clinical samples, and American Type Culture Collection (ATCC) Virome Virus Mix. Sensitivity and specificity were 95% and higher for both methods using the synthetic and reference controls as gold standard. Combining thresholds for viral sequence read counts and genome coverage [respectively 500 reads per million (RPM) and 10% coverage] resulted in optimal prediction of true positive results. Limits of detection were approximately 50-500 copies/mL for both methods as determined by ddPCR. Increasing proportions of spike-in cell-free human background sequences up to 99.999% (50 ng/mL) did not negatively affect viral detection, suggesting effective capture of viral sequences. These data show analytical performances in ranges applicable to clinical samples, for both probe hybridization metagenomic approaches. This study supports further steps toward more widespread use of viral metagenomics for pathogen detection, in clinical and surveillance settings using low biomass samples. IMPORTANCE Viral metagenomics has been gradually applied for broad-spectrum pathogen detection of infectious diseases, surveillance of emerging diseases, and pathogen discovery. Viral enrichment by probe hybridization methods has been reported to significantly increase the sensitivity of viral metagenomics. During the past years, a specific hybridization panel distributed by Roche has been adopted in a broad range of different clinical and zoonotic settings. Recently, Twist Bioscience has released a new hybridization panel targeting human and animal viruses. This is the first report comparing the performance of viral metagenomic hybridization panels.
Collapse
|
7
|
Franco LC, Ahmed M, Kendra CG, Sperling RM, Van Benten K, Lavik JP, Emery CL, Relich RF, Gavina K. Validation of a qualitative real-time PCR assay for the detection of Candida auris in hospital inpatient screening. J Clin Microbiol 2024; 62:e0015824. [PMID: 38690882 DOI: 10.1128/jcm.00158-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 04/06/2024] [Indexed: 05/03/2024] Open
Abstract
Candida auris is a multidrug-resistant opportunistic fungal pathogen capable of causing serious infections and healthcare-associated outbreaks. Screening for colonization with C. auris has become routine and is recommended in many hospitals and healthcare facilities as an infection control and prevention strategy. Subsequently, and since there are currently no FDA-approved tests for this purpose, clinical microbiology laboratories have become responsible for developing protocols to detect C. auris using axial and inguinal screening swabs. In a College of American Pathologists-accredited large academic healthcare center setting, we implemented a laboratory-developed nucleic-acid amplification test for the detection of C. auris DNA. Our test validation evaluated the performance of the DiaSorin C. auris primer set used in a real-time qualitative PCR assay on the LIAISON MDX thermocycler with the Simplexa Universal Disc. The assay was highly sensitive and specific, with a limit of detection of 1-2 CFU/reaction, with no observed cross-reactivity with other Candida spp., bacterial skin commensal organisms or commonly encountered viruses. When run in parallel with a culture-based detection method, the PCR assay was 100% sensitive and specific. The assay was precise, with low variability between replicates within and between runs. Lastly, pre-analytical factors, including swab storage time, temperature, and transport media, were assessed and found to have no significant effect on the detection of C. auris at variable concentrations. Taken together, this study expands the available options for nucleic acid detection of C. auris and characterizes pre-analytical factors for implementation in both high- and low-volume laboratory settings. IMPORTANCE This study overviews the validation and implementation of a molecular screening tool for the detection of Candida auris in a College of American Pathologist-accredited clinical laboratory. This molecular laboratory-developed test is both highly sensitive and specific and has significant health-system cost-savings associated with significantly reduced turn-around-time compared to traditional standard-of-care culture-based work up. This method and workflow is of interest to support clinical microbiology diagnostics and to help aid in hospital inpatient, and infection prevention control screening.
Collapse
|
8
|
Poljak M, Oštrbenk Valenčak A, Cuschieri K, Bohinc KB, Arbyn M. 2023 global inventory of commercial molecular tests for human papillomaviruses (HPV). J Clin Virol 2024; 172:105671. [PMID: 38518504 DOI: 10.1016/j.jcv.2024.105671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 02/28/2024] [Accepted: 03/13/2024] [Indexed: 03/24/2024]
Abstract
To suit the needs of the human papillomaviruses (HPV) community comprehensively, a range of commercial HPV tests with different performance characteristics are required. Four periodic inventories of commercial HPV molecular tests present in the global market were published previously in 2010, 2012, 2015 and 2020. For the fifth inventory, data were retrieved from internal files and a detailed search using the main bibliographic databases as well as general internet search without period or language restrictions was performed in December 2023. At least 264 distinct HPV tests (and 511 test variants) were available globally in December 2023. A small 2020-2023 net increase in total numbers was observed, but with a strong introduction/withdrawal dynamic: 86 new distinct HPV tests (and 141 variants) were introduced and 76 tests (and 55 variants) were withdrawn from the market in the last four years. Although quality improvement of some tests was recorded, half of all HPV tests are still without a single peer-reviewed publication, and 79 % of tests are without published evidence that demonstrate performance characteristics are in line with requirements agreed in the HPV community. Only a relatively small pool of tests fulfill the operational/performance characteristics required to meet the global cervical cancer screening challenge. Although clinical and analytical performance characteristics of many commercial HPV tests are largely unknown, such tests are used worldwide in daily clinical practice and research, with potentially deleterious consequences. Due to this long-lasting unfavorable situation, significant scope for improvement persists for both manufacturers of HPV tests and the HPV community.
Collapse
|
9
|
Lübke N, Walker A, Obermeier M, Camdereli J, Paluschinski M, Walotka L, Schupp AK, Tometten I, Hauka S, Heger E, Timm J. Real-world performance of the NeuMoDx™ HCV Quant Test for quantification of hepatitis C virus (HCV)-RNA. J Virol Methods 2024; 327:114937. [PMID: 38614281 DOI: 10.1016/j.jviromet.2024.114937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 03/18/2024] [Accepted: 04/05/2024] [Indexed: 04/15/2024]
Abstract
Quantification of hepatitis C virus (HCV)-RNA in serum or plasma samples is an essential parameter in HCV diagnostics. Here, the NeuMoDx™Molecular System (Qiagen) was tested for the most common HCV genotypes and compared to the cobas c6800 system (Roche). HCV-RNA from 131 plasma/serum samples from chronically infected patients was determined in parallel on the NeuMoDx and c6800 systems. Linearity was analysed using the four most common HCV genotypes (1-4) in our cohort. The coefficient of variation (CV) within (intra-assay) and between (inter-assay) runs was calculated based on HCV-RNA concentration. Quantitative HCV-RNA results were highly correlated on both test systems (R2 = 0.7947; y = 0.94 x + 0.37). On average, the NeuMoDx and c6800 HCV RNA levels showed a mean difference of only 0.05 log10 IU/mL but with a broad distribution (±1.2 2 x SD). The NeuMoDx demonstrated very good linearity across all HCV genotypes tested at concentrations between 1.7 and 6.2 log10 IU/mL (R2 range: 0.9257-0.9991) with the highest mean coefficient of determination for genotype 1 (R2 = 0.9909). The mean intra- and inter-assay CV for both serum and plasma samples was <5 %. The NeuMoDx HCV-RNA Assay demonstrates high subtype-independent comparability, linearity, and reproducibility for the quantification of HCV-RNA in serum and plasma samples from chronically infected patients.
Collapse
|
10
|
Xie YL, Eichberg C, Hapeela N, Nakabugo E, Anyango I, Arora K, Korte JE, Odero R, van Heerden J, Zemanay W, Kennedy S, Nabeta P, Hanif M, Rodrigues C, Skrahina A, Stevens W, Dietze R, Liu X, Ellner JJ, Alland D, Joloba ML, Schumacher SG, McCarthy KD, Nakiyingi L, Dorman SE. Xpert MTB/RIF Ultra versus mycobacterial growth indicator tube liquid culture for detection of Mycobacterium tuberculosis in symptomatic adults: a diagnostic accuracy study. THE LANCET. MICROBE 2024; 5:e520-e528. [PMID: 38608680 DOI: 10.1016/s2666-5247(24)00001-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 01/02/2024] [Accepted: 01/04/2024] [Indexed: 04/14/2024]
Abstract
BACKGROUND Xpert MTB/RIF Ultra (Ultra) is an automated molecular test for the detection of Mycobacterium tuberculosis in sputum. We compared the sensitivity of Ultra to that of mycobacterial growth indicator tube (MGIT) liquid culture, considered the most sensitive assay in routine clinical use. METHODS In this prospective, multicentre, cross-sectional diagnostic accuracy study, we used a non-inferiority design to assess whether the sensitivity of a single Ultra test was non-inferior to that of a single liquid culture for detection of M tuberculosis in sputum. We enrolled adults (age ≥18 years) with pulmonary tuberculosis symptoms in 11 countries and each adult provided three sputum specimens with a minimum volume of 2 mL over 2 days. Ultra was done directly on sputum 1, and Ultra and MGIT liquid culture were done on resuspended pellet from sputum 2. Results of MGIT and solid media cultures done on sputum 3 were considered the reference standard. The pre-defined non-inferiority margin was 5·0%. FINDINGS Between Feb 18, 2016, and Dec 4, 2019, we enrolled 2906 participants. 2600 (89%) participants were analysed, including 639 (25%) of 2600 who were positive for tuberculosis by the reference standard. Of the 2357 included in the non-inferiority analysis, 877 (37%) were HIV-positive and 984 (42%) were female. Sensitivity of Ultra performed directly on sputum 1 was non-inferior to that of sputum 2 MGIT culture (MGIT 91·1% vs Ultra 91·9%; difference -0·8 percentage points; 95% CI -2·8 to 1·1). Sensitivity of Ultra performed on sputum 2 pellet was also non-inferior to that of sputum 2 MGIT (MGIT 91·1% vs Ultra 91·9%; difference -0·8 percentage points; -2·7 to 1·0). INTERPRETATION For the detection of M tuberculosis in sputum from adults with respiratory symptoms, there was no difference in sensitivity of a single Ultra test to that of a single MGIT culture. Highly sensitive, rapid molecular approaches for M tuberculosis detection, combined with advances in genotypic methods for drug resistance detection, have potential to replace culture. FUNDING US National Institute of Allergy and Infectious Diseases.
Collapse
|
11
|
Huggett JF, O'Sullivan DM, Cowen S, Cleveland MH, Davies K, Harris K, Moran-Gilad J, Winter A, Braybrook J, Messenger M. Ensuring accuracy in the development and application of nucleic acid amplification tests (NAATs) for infectious disease. Mol Aspects Med 2024; 97:101275. [PMID: 38772082 DOI: 10.1016/j.mam.2024.101275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 03/29/2024] [Accepted: 04/22/2024] [Indexed: 05/23/2024]
Abstract
Diagnostic tests were heralded as crucial during the Coronavirus disease (COVID-19) pandemic with most of the key methods using bioanalytical approaches that detected larger molecules (RNA, protein antigens or antibodies) rather than conventional clinical biochemical techniques. Nucleic Acid Amplification Tests (NAATs), like the Polymerase Chain Reaction (PCR), and other molecular methods, like sequencing (that often work in combination with NAATs), were essential to the diagnosis and management during COVID-19. This was exemplified both early in the pandemic but also later on, following the emergence of new genetic SARS-CoV-2 variants. The 100 day mission to respond to future pandemic threats highlights the need for effective diagnostics, therapeutics and vaccines. Of the three, diagnostics represents the first opportunity to manage infectious diseases while also being the most poorly supported in terms of the infrastructure needed to demonstrate effectiveness. Where performance targets exist, they are not well served by consensus on how to demonstrate they are being met; this includes analytical factors such as limit of detection (LOD) false positive results as well as how to approach clinical evaluation. The selection of gold standards or use of epidemiological factors such as predictive value, reference ranges or clinical thresholds are seldom correctly considered. The attention placed on molecular diagnostic tests during COVID-19 illustrates important considerations and assumptions on the use of these methods for infectious disease diagnosis and beyond. In this manuscript, we discuss state-of-the-art approaches to diagnostic evaluation and explore how they may be better tailored to diagnostic techniques like NAATs to maximise the impact of these highly versatile bioanalytical tools, both generally and during future outbreaks.
Collapse
|
12
|
A C, N C, A DS, A P, E Y, F G, M C. Validation of a rapid molecular detection test for gram-negative multidrug-resistant bacteria in rectal swabs upon admission of patients to the intensive care unit. Diagn Microbiol Infect Dis 2024; 109:116250. [PMID: 38479092 DOI: 10.1016/j.diagmicrobio.2024.116250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 03/05/2024] [Accepted: 03/07/2024] [Indexed: 04/30/2024]
Abstract
In ICU settings, screening patients upon admission for potential multiresistant bacteria (BMR) carriers is crucial. Traditionally, clinical decisions relied on delayed culture results, but a rapid PCR molecular test called RealCycler-Rezero-U/G (Progenie-molecular©), emerged as an alternative. This study aimed to validate its effectiveness in detecting gram-negative BMR in rectal swabs at ICU admission. Over 24 months, an observational study was conducted on 1,234 admitted patients, with 217 meeting isolation criteria and undergoing both PCR and culture tests. Results showed a 17.5 % positive rate for screening. The PCR test exhibited impressive accuracy at 98.6 % and a strong negative predictive value of 99.4 %. The area under the ROC curve (AUC) was 0.98, indicating high reliability. Notably, PCR results were available 44.5 h earlier than culture. In conclusion, PCR-based molecular testing for gram-negative BMR offers excellent diagnostic performance and a valuable negative predictive value, making it a suitable screening tool for ICU admissions.
Collapse
|
13
|
Silva SJRD, Magalhães JJFD, Matthews Q, Divarzak ALL, Mendes RPG, Santos BNR, Cabral DGDA, Silva JBD, Kohl A, Pardee K, Pena L. Development and field validation of a reverse transcription loop-mediated isothermal amplification assay (RT-LAMP) for the rapid detection of chikungunya virus in patient and mosquito samples. Clin Microbiol Infect 2024; 30:810-815. [PMID: 38460820 PMCID: PMC11161457 DOI: 10.1016/j.cmi.2024.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 03/02/2024] [Accepted: 03/04/2024] [Indexed: 03/11/2024]
Abstract
OBJECTIVES We aimed to develop a reverse transcription loop-mediated isothermal amplification (RT-LAMP) platform for the rapid detection of chikungunya virus (CHIKV) in both patient and mosquito samples from Brazil. METHODS We optimized an RT-LAMP assay and then evaluated the specificity and sensitivity using visual detection. In comparison with the RT-qPCR reference method, we validated the utility of this assay as a molecular diagnostic test in a reference laboratory for arbovirus diagnostics using 100 serum samples collected from suspected CHIKV cases. RESULTS Our RT-LAMP assay specifically detected CHIKV without cross-reactivity against other arboviruses. The limit of detection of our RT-LAMP was estimated in -1.18 PFU (confidence interval [CI] ranging from -2.08 to 0.45), resulting in a similar analytical sensitivity when directly compared with the reference standard RT-qPCR assay. Then, we demonstrate the ability of our RT-LAMP assay to detect the virus in different human specimens (serum, urine, and saliva), and crude lysate of Aedes aegypti mosquitoes in as little as 20-30 minutes and without a separate RNA isolation step. Lastly, we showed that our RT-LAMP assay could be lyophilized and reactivated by adding water, indicating potential for room-temperature storage. Our RT-LAMP had a clinical sensitivity of 100% (95% CI, 90.97-100.00%), clinical specificity of 96.72% (95% CI, 88.65-99.60%), and overall accuracy of 98.00% (95% CI, 92.96-99.76%). DISCUSSION Taken together, these findings indicate that the RT-LAMP assay reported here solves important practical drawbacks to the deployment of molecular diagnostics in the field and can be used to improve testing capacity, particularly in low- and middle-income countries.
Collapse
|
14
|
Steadman A, Andama A, Ball A, Mukwatamundu J, Khimani K, Mochizuki T, Asege L, Bukirwa A, Kato JB, Katumba D, Kisakye E, Mangeni W, Mwebe S, Nakaye M, Nassuna I, Nyawere J, Nakaweesa A, Cook C, Phillips P, Nalugwa T, Bachman CM, Semitala FC, Weigl BH, Connelly J, Worodria W, Cattamanchi A. New Manual Quantitative Polymerase Chain Reaction Assay Validated on Tongue Swabs Collected and Processed in Uganda Shows Sensitivity That Rivals Sputum-based Molecular Tuberculosis Diagnostics. Clin Infect Dis 2024; 78:1313-1320. [PMID: 38306491 DOI: 10.1093/cid/ciae041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 12/06/2023] [Accepted: 01/26/2024] [Indexed: 02/04/2024] Open
Abstract
BACKGROUND Sputum-based testing is a barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce sputum, and sputum processing increases assay complexity and cost. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. METHODS From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at 2 health centers in Kampala, Uganda. We collected demographic and clinical information, sputum for TB testing (Xpert MTB/RIF Ultra and 2 liquid cultures), and tongue swabs for same-day quantitative polymerase chain reaction (qPCR) testing. We evaluated tongue swab qPCR diagnostic accuracy versus sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared 2 swab types (Copan FLOQSWAB and Steripack spun polyester). RESULTS Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were diagnosed with human immunodeficiency virus, and 32.0% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% (95% confidence interval [CI]: 96.2-99.1) of participants. Tongue swab qPCR sensitivity was 92.6% (95% CI: 86.5 to 96.0) and specificity was 99.1% (95% CI: 96.9 to 99.8) versus microbiological reference standard. A single tongue swab recovered a 7-log range of TB copies, with a decreasing recovery trend among 4 serial swabs. Swab types performed equivalently. CONCLUSIONS Tongue swabs are a promising alternative to sputum for molecular diagnosis of TB, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.
Collapse
|
15
|
Lewis JD, Salipante SJ. Development of advanced control material for reverse transcription-mediated bacterial nucleic acid amplification tests. J Clin Microbiol 2024; 62:e0024324. [PMID: 38629844 DOI: 10.1128/jcm.00243-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 03/28/2024] [Indexed: 05/09/2024] Open
Abstract
Detection of bacterial RNA by nucleic acid amplification tests (NAATs), such as reverse transcription PCR (RT-PCR) and reverse transcription loop-mediated isothermal amplification (RT-LAMP), offers distinct advantages over DNA-based methods. However, such assays also present challenges in ascertaining positive and internal control material that can reliably monitor success over all phases of testing (bacterial lysis, nucleic acid recovery, reverse transcription, amplification, and signal detection): since they are unable to distinguish between amplification of bacterial RNA transcripts and the DNA templates that encode them, using intact organisms as controls can inform cell lysis but not successful detection of RNA. We developed a control strategy for RNA-based bacterial NAATs that allows ready discrimination of RNA from DNA templates using self-splicing bacterial introns, such that those nucleic acids ultimately encode different sequences. We engineered two vectors encoding synthetic transgenes based on this principle, one that is active in the Gram-negative bacterium Escherichia coli and one that functions in both E. coli and the Gram-positive organism Staphylococcus aureus. We subsequently designed RT-LAMP assays that either target RNA and DNA from transgenic organisms or target RNA exclusively and demonstrated the specificity of amplification using purified nucleic acids. Using multiplex fluorescent RT-LAMP of heat-lysed specimens, we showed the practicality of deploying such transgenic organisms as an internal control to ascertain sample integrity and assay performance during clinical diagnostic testing. Our approach has broad utility for RNA-based bacterial NAATs, especially point-of-care assays and other applications where nucleic acids are nonspecifically liberated for testing.
Collapse
|
16
|
Hauner A, Onwuchekwa C, Ariën KK. Sample-to-result molecular diagnostic platforms and their suitability for infectious disease testing in low- and middle-income countries. Expert Rev Mol Diagn 2024; 24:423-438. [PMID: 38747017 DOI: 10.1080/14737159.2024.2353690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 05/07/2024] [Indexed: 05/22/2024]
Abstract
INTRODUCTION Diagnostics are an essential, undervalued part of the health-care system. For many diseases, molecular diagnostics are the gold standard, but are not easy to implement in Low- and Middle-Income Countries (LMIC). Sample-to-result (S2R) platforms combining all procedures in a closed system could offer a solution. In this paper, we investigated their suitability for implementation in LMIC. AREAS COVERED A scorecard was used to evaluate different platforms on a range of parameters. Most platforms scored fairly on the platform itself, ease-of-use and test consumables; however, shortcomings were identified in cost, distribution and test panels tailored to LMIC needs. The diagnostic coverage for common infectious diseases was found to have a wider coverage in high-income countries (HIC) than LMIC. A literature study showed that in LMIC, these platforms are mainly used as diagnostic tools or evaluation of diagnostic performance, with a minority assessing the operational characteristics or the clinical utility. In this narrative review, we identified various points for adaptation of S2R platforms to LMIC conditions. EXPERT OPINION For S2R platforms to be suitable for implementation in LMIC some modifications by the manufacturers could be considered. Furthermore, strengthening health systems and digitalization are vital; as are smaller, cheaper, faster, and sustainable technologies.
Collapse
|
17
|
Evans M, Kendall T. Practical considerations for pathological diagnosis and molecular profiling of cholangiocarcinoma: an expert review for best practices. Expert Rev Mol Diagn 2024; 24:393-408. [PMID: 38752560 DOI: 10.1080/14737159.2024.2353696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 05/07/2024] [Indexed: 05/22/2024]
Abstract
INTRODUCTION Advances in precision medicine have expanded access to targeted therapies and demand for molecular profiling of cholangiocarcinoma (CCA) patients in routine clinical practice. However, pathologists face challenges in establishing a definitive intrahepatic CCA (iCCA) diagnosis while preserving sufficient tissue for molecular profiling. Additionally, they frequently face challenges in optimal tissue handling to preserve nucleic acid integrity. AREAS COVERED This article first identifies the challenges in establishing a definitive diagnosis of iCCA in a lesional liver biopsy while preserving sufficient tissue for molecular profiling. Then, the authors explore the clinical value of molecular profiling, the basic principles of single gene and next-generation sequencing (NGS) techniques, and the challenges in tissue sampling for genomic testing. They also propose an algorithm for best practice in tissue management for molecular profiling of CCA. EXPERT OPINION Several practical challenges face pathologists during tissue sampling and processing for molecular profiling. Optimized tissue processing, careful tissue handling, and selection of appropriate approaches to molecular testing are essential to ensure that the highest possible quality of diagnostic information is provided in the greatest proportion of cases.
Collapse
|
18
|
Avivi MY, Touitou N, Rohana H, Lerrer B, Shav-Tal Y, Peretz A, Cohen HY. Nucleic acid hybridization-based detection of pathogenic RNA using microscale thermophoresis. J Biol Chem 2024; 300:105676. [PMID: 38278326 PMCID: PMC10881438 DOI: 10.1016/j.jbc.2024.105676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 01/10/2024] [Accepted: 01/12/2024] [Indexed: 01/28/2024] Open
Abstract
Infectious diseases are one of the world's leading causes of morbidity. Their rapid spread emphasizes the need for accurate and fast diagnostic methods for large-scale screening. Here, we describe a robust method for the detection of pathogens based on microscale thermophoresis (MST). The method involves the hybridization of a fluorescently labeled DNA probe to a target RNA and the assessment of thermophoretic migration of the resulting complex in solution within a 2 to 30-time window. We found that the thermophoretic migration of the nucleic acid-based probes is primarily determined by the fluorescent molecule used, rather than the nucleic acid sequence of the probe. Furthermore, a panel of uniformly labeled probes that bind to the same target RNA yields a more responsive detection pattern than a single probe, and moreover, can be used for the detection of specific pathogen variants. In addition, intercalating agents (ICA) can be used to alter migration directionality to improve detection sensitivity and resolving power by several orders of magnitude. We show that this approach can rapidly diagnose viral SARS-CoV2, influenza H1N1, artificial pathogen targets, and bacterial infections. Furthermore, it can be used for anti-microbial resistance testing within 2 h, demonstrating its diagnostic potential for early pathogen detection.
Collapse
|
19
|
Peela SCM, Sistla S. Utility of quantitative loop mediated isothermal amplification (qLAMP) assay for the diagnosis of invasive pneumococcal disease (IPD). Indian J Med Microbiol 2024; 48:100575. [PMID: 38537871 DOI: 10.1016/j.ijmmb.2024.100575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 03/16/2024] [Accepted: 03/25/2024] [Indexed: 05/08/2024]
Abstract
PURPOSE Quantitative LAMP (qLAMP) assay is one of the recent and emerging diagnostic tests for infectious diseases. Only a few studies exist comparing this assay with quantitative real-time PCR (qPCR) for the diagnosis of invasive pneumococcal disease (IPD). AIM To compare the diagnostic performance of qLAMP assay with qPCR targeting autolysin gene for the diagnosis of invasive pneumococcal disease. METHODS Ninety six blood samples and 73 CSF samples from patients clinically suspected with community acquired pneumonia and acute meningitis were tested by qPCR and qLAMP assays using previously published primers and protocols. The qPCR was considered as the gold standard test and the diagnostic performance was assessed by calculating sensitivity, specificity, positive and negative predictive values, and kappa coefficient for the level of agreement between the tests. Chi-squared/Fisher exact test was used to compare categorical variables (positive/negative). RESULTS Thirty two blood samples and 22 CSF samples were positive by qPCR while 24 and 20 samples were positive by qLAMP assay respectively. The sensitivity of qLAMP assay was only 86.4% and 75% when tested on CSF and blood samples respectively. However, the qLAMP assay was in substantial to almost perfect agreement when compared with qPCR. The results were statistically significant in both sample types (P < 0.001). CONCLUSIONS The performance of qLAMP assay can vary based on the specimen type. It has very high specificity and had substantial to almost perfect agreement, and thus may be an alternative to qPCR for the diagnosis of IPD.
Collapse
|
20
|
Gandhi T, Shah A, Gautam N, Meena N. One- versus two-specimen Xpert strategy to discontinue airborne isolation in suspected pulmonary tuberculosis: systematic review and meta-analysis. Clin Microbiol Infect 2023; 29:1385-1392. [PMID: 37479182 DOI: 10.1016/j.cmi.2023.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 05/29/2023] [Accepted: 07/13/2023] [Indexed: 07/23/2023]
Abstract
BACKGROUND Evaluation of a patient with suspected pulmonary tuberculosis (TB) involves initiation of airborne infection isolation (AII). However, guidelines detailing discontinuation of AII utilizing the Xpert MTB/RIF provide little clarity between use of one-specimen (1-Xpert') versus two-specimens (2-Xpert'). OBJECTIVES To evaluate the diagnostic accuracy of one-Xpert versus two-Xpert strategy in guiding discontinuation of AII. METHODS Data sources: PubMed, Embase, and EBSCO databases. STUDY ELIGIBILITY CRITERIA Studies providing diagnostic accuracy data for one- versus two-Xperts in discontinuation of AII. PARTICIPANTS Adult patients with suspected TB. TESTS Xpert MTB/RIF on one- versus two-sputum specimens. Reference standard: Solid and liquid culture media. Assessment of risk of bias: Quality Assessment of Diagnostic Accuracy Studies tool was used. Methods of data synthesis: Meta-analysis was performed to calculate the pooled sensitivities and specificities using Stata 17.2. RESULTS Four studies were included involving 1776 patients. A total of 68% were males, 36% were HIV positive, and 80% participants belonged to the United States. In patients with suspected pulmonary TB, 7% (95% CI, 6-9%) participants were found to have culture-positive MTB. For one-Xpert strategy, the pooled sensitivity was 86% (95% CI, 75-92%; I2, 1.05%) and specificity was 100% (95% CI, 99-100%; I2, 36%). Two-Xpert strategy had a pooled sensitivity of 92% (95% CI, 84-96%; I2, 16%) and a specificity of 100% (95% CI, 98-100%; I2, 27%). There was statistically significant difference between sensitivities of one-Xpert and two-Xpert strategies (p 0.05) with no statistically significant difference in their specificities. DISCUSSION The results of this review must be interpreted in the context of a predominantly low-TB prevalence setting. Two-Xpert strategy has an incrementally higher sensitivity when compared with one-Xpert strategy with similar specificities between the two. Obtaining a second Xpert is crucial for individuals with a continued high suspicion for TB or those at a high risk of morbidity/mortality from TB.
Collapse
|
21
|
Shukla JL, Husain AA, Bhan S, Singh LR, Kashyap RS. Diagnostic utility of LAMP PCR targeting bcsp-31 gene for human brucellosis infection. Indian J Med Microbiol 2023; 44:100354. [PMID: 37356844 DOI: 10.1016/j.ijmmb.2023.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/27/2022] [Accepted: 01/21/2023] [Indexed: 06/27/2023]
Abstract
PURPOSE Human brucellosis is a neglected zoonotic disease of significant public health concern. Molecular diagnosis of brucella remains challenging in low resource settings, due to the high infrastructure and cost involved. Loop-mediated isothermal amplification (LAMP) is a rapid point of care polymerase chain reaction (PCR) with the utility of on-field molecular diagnosis and offers a convenient alternative to conventional PCR. In the present study, we developed and evaluated the diagnostic utility of in house LAMP PCR targeting the Brucella genus-specific bcsp-31 gene in patients having febrile illness. MATERIALS AND METHODS The analytical sensitivity and specificity of bcsp-31 LAMP PCR was first evaluated using brucella (n = 8) and non-brucella cultures (n = 5), along with spiked clinical samples. The overall diagnostic utility of developed LAMP PCR was then further evaluated in 393 human samples suspected of brucellosis. RESULTS The developed LAMP PCR could detect as low as 8 fg of DNA by visual detection within 35min. We report sensitivity and specificity of the developed LAMP PCR as 90.91% and 99.37%.The accuracy of the developed test assay was found to be 98.60%. In clinical samples, LAMP gave positivity of 20% with the concordance of 89% with conventional PCR. CONCLUSION To conclude, a rapid, efficacious, sensitive LAMP PCR targeting the bcsp 31 gene was developed. The existing LAMP PCR can be used as a point of care screening test in various low resource endemic setting in lieu of conventional PCR for estimation of prevalence data, diagnosis and treatment of brucellosis.
Collapse
|
22
|
Momeni-Boroujeni A, Yousefi E, Balakrishnan R, Riviere S, Kertowidjojo E, Hensley ML, Ladanyi M, Ellenson LH, Chiang S. Molecular-Based Immunohistochemical Algorithm for Uterine Leiomyosarcoma Diagnosis. Mod Pathol 2023; 36:100084. [PMID: 36788080 PMCID: PMC10191186 DOI: 10.1016/j.modpat.2022.100084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 12/01/2022] [Accepted: 12/15/2022] [Indexed: 01/11/2023]
Abstract
The morphologic assessment of uterine leiomyosarcoma (LMS) may be challenging, and diagnostic immunohistochemical (IHC) analysis is currently lacking. We evaluated the genomic landscape of 167 uterine LMS by targeted next-generation sequencing (NGS) to identify common genomic alterations. IHC analyses corresponding to these genomic landmarks were applied to a test cohort of 16 uterine LMS, 6 smooth muscle tumors of uncertain malignant potential (STUMP), and 6 leiomyomas with NGS data and a validation cohort of 8 uterine LMS, 12 STUMP, 21 leiomyomas and leiomyoma variants, 7 low-grade endometrial stromal sarcomas, and 2 diagnostically challenging uterine smooth muscle tumors. IHC results were individually interpreted by 3 pathologists blinded to NGS data. Overall, 94% of LMS showed ≥1 genomic alteration involving TP53, RB1, ATRX, PTEN, CDKN2A, or MDM2, with 80% showing alterations in ≥2 of these genes. In the test cohort, an initial panel of p53, Rb, PTEN, and ATRX was applied, followed by a panel of DAXX, MTAP, and MDM2 in cases without abnormalities. Abnormal p53, Rb, PTEN, and ATRX IHC expression was seen in 75%, 88%, 44%, and 38% of LMS, respectively, in the test cohort. Two or more abnormal IHC results among these markers were seen in 81% of LMS. STUMPs demonstrated only 1 IHC abnormality involving these markers. No IHC abnormalities were seen in leiomyomas. In the validation cohort, abnormal p53, Rb, and PTEN IHC results were seen in LMS, whereas rare STUMP or leiomyomas with bizarre nuclei showed IHC abnormalities involving only 1 of the markers. Abnormalities in ≥2 markers were present in both diagnostically challenging smooth muscle tumors, confirming LMS. Concordance was excellent among pathologists in the interpretation of IHC (κ = 0.97) and between IHC and NGS results (κ = 0.941). Uterine LMS exhibit genomic landmark alterations for which IHC surrogates exist, and a diagnostic algorithm involving molecular-based IHC may aid in the evaluation of unusual uterine smooth muscle tumors.
Collapse
|
23
|
Manta FSDN, Jacomasso T, Rampazzo RDCP, Moreira SJM, Zahra NM, Cole ST, Avanzi C, Leal-Calvo T, Vasconcellos SEG, Suffys P, Ribeiro-Alves M, Krieger MA, Costa ADT, Moraes MO. Development and validation of a multiplex real-time qPCR assay using GMP-grade reagents for leprosy diagnosis. PLoS Negl Trop Dis 2022; 16:e0009850. [PMID: 35180224 PMCID: PMC8893668 DOI: 10.1371/journal.pntd.0009850] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 03/03/2022] [Accepted: 01/26/2022] [Indexed: 11/18/2022] Open
Abstract
Leprosy is a chronic dermato-neurological disease caused by Mycobacterium leprae, an obligate intracellular bacterium. Timely detection is a challenge in leprosy diagnosis, relying on clinical examination and trained health professionals. Furthermore, adequate care and transmission control depend on early and reliable pathogen detection. Here, we describe a qPCR test for routine diagnosis of leprosy-suspected patients. The reaction simultaneously amplifies two specific Mycobacterium leprae targets (16S rRNA and RLEP), and the human 18S rRNA gene as internal control. The limit of detection was estimated to be 2.29 copies of the M. leprae genome. Analytical specificity was evaluated using a panel of 20 other skin pathogenic microorganisms and Mycobacteria, showing no cross-reactivity. Intra- and inter-operator Cp variation was evaluated using dilution curves of M. leprae DNA or a synthetic gene, and no significant difference was observed between three operators in two different laboratories. The multiplex assay was evaluated using 97 patient samples with clinical and histopathological leprosy confirmation, displaying high diagnostic sensitivity (91%) and specificity (100%). Validation tests in an independent panel of 50 samples confirmed sensitivity and specificity of 97% and 98%, respectively. Importantly, assay performance remained stable for at least five months. Our results show that the newly developed multiplex qPCR effectively and specifically detects M. leprae DNA in skin samples, contributing to an efficient diagnosis that expedites the appropriate treatment. Leprosy is a chronic dermato-neurological disease caused by Mycobacterium leprae, an obligate intracellular bacterium. Diagnosis of leprosy often relies on skin examinations for clinical signs, bacilli staining from skin smears and invasive skin biopsies. However, the spectrum of clinical manifestations and, often, low bacilli numbers can hinder accurate diagnosis. Timely detection is a challenge in leprosy diagnosis, relying on clinical examination and requiring trained health professionals. Proper intervention for adequate care and transmission control depends on early and reliable pathogen detection. Quantitative PCR methods for detecting bacterial DNA are more sensitive and could aid in differentially diagnosing leprosy from other dermatological conditions. In this work, we present a new multiplex PCR that was assessed for quality control standards, and the data indicate that the assay is stable and reproducible. The results presented here are the basis of a novel and robust tool with potential to increase the accuracy of leprosy diagnosis in routine or reference laboratories.
Collapse
|
24
|
Kozak RA, Rutherford C, Richard-Greenblatt M, Chau NYE, Cabrera A, Biondi M, Borlang J, Day J, Osiowy C, Ramachandran S, Mayer N, Glaser L, Smieja M. Development and Evaluation of a Molecular Hepatitis A Virus Assay for Serum and Stool Specimens. Viruses 2022; 14:v14010159. [PMID: 35062362 PMCID: PMC8777614 DOI: 10.3390/v14010159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 01/02/2022] [Accepted: 01/06/2022] [Indexed: 11/26/2022] Open
Abstract
Hepatitis A virus (HAV) is an emerging public health concern and there is an urgent need for ways to rapidly identify cases so that outbreaks can be managed effectively. Conventional testing for HAV relies on anti-HAV IgM seropositivity. However, studies estimate that 10–30% of patients may not be diagnosed by serology. Molecular assays that can directly detect viral nucleic acids have the potential to improve diagnosis, which is key to prevent the spread of infections. In this study, we developed a real-time PCR (RT-PCR) assay to detect HAV RNA for the identification of acute HAV infection. Primers were designed to target the conserved 5′-untranslated region (5′-UTR) of HAV, and the assay was optimized on both the Qiagen Rotor-Gene and the BD MAX. We successfully detected HAV from patient serum and stool samples with moderate differences in sensitivity and specificity depending on the platform used. Our results highlight the clinical utility of using a molecular assay to detect HAV from various specimen types that can be implemented in hospitals to assist with diagnostics, treatment and prevention.
Collapse
|
25
|
Hatami F, Rabiei MM, Javandoust Gharehbagh F, Pourhoseingholi MA, Sabeti S, Kheyrian M, Alavi Darazam I. One-step and sequential SARSCOV-2 polymerase chain reaction tests would not work every time. J Clin Lab Anal 2022; 36:e24226. [PMID: 34997789 PMCID: PMC8842140 DOI: 10.1002/jcla.24226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 12/24/2021] [Accepted: 12/27/2021] [Indexed: 11/18/2022] Open
Abstract
Introduction RT‐PCR is widely used as a diagnostic test for the detection of SARS‐CoV‐2. In this study, we aim to describe the clinical utility of serial PCR testing in the final detection of COVID‐19. Method We collected multiple nasopharyngeal swab samples from patients who had negative RT‐PCR test on the first day after hospitalization. RT‐PCR tests were performed on the second day for all patients with initial negative result. For the patients with secondary negative results on day 2, tertiary RT‐PCR tests were performed on day 3 after hospitalization. Result Among 68 patients with initial negative test results, at the end of follow‐up, the mortality number was 20 (29.4%). About 33.8% of patients had subsequent positive PCR test results for the second time and 17.4% of the patients who performed third PCR test had positive result. Conclusion Based on this study, serial RT‐PCR testing is unlikely to yield additional information.
Collapse
|