1
|
Harguindeguy M, Fissore D. Micro Freeze-Dryer and Infrared-Based PAT: Novel Tools for Primary Drying Design Space Determination of Freeze-Drying Processes. Pharm Res 2021; 38:707-719. [PMID: 33686561 PMCID: PMC8057969 DOI: 10.1007/s11095-021-03023-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 02/23/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE Present (i) an infrared (IR)-based Process Analytical Technology (PAT) installed in a lab-scale freeze-dryer and (ii) a micro freeze-dryer (MicroFD®) as effective tools for freeze-drying design space calculation of the primary drying stage. METHODS The case studies investigated are the freeze-drying of a crystalline (5% mannitol) and of an amorphous (5% sucrose) solution processed in 6R vials. The heat (Kv) and the mass (Rp) transfer coefficients were estimated: tests at 8, 13 and 26 Pa were carried out to assess the chamber pressure effect on Kv. The design space of the primary drying stage was calculated using these parameters and a well-established model-based approach. The results obtained using the proposed tools were compared to the ones in case Kv and Rp were estimated in a lab-scale unit through gravimetric tests and a thermocouple-based method, respectively. RESULTS The IR-based method allows a non-gravimetric estimation of the Kv values while with the micro freeze-dryer gravimetric tests require a very small number of vials. In both cases, the obtained values of Kv and Rp, as well as the resulting design spaces, were all in very good agreement with those obtained in a lab-scale unit through the gravimetric tests (Kv) and the thermocouple-based method (Rp). CONCLUSIONS The proposed tools can be effectively used for design space calculation in substitution of other well-spread methods. Their advantages are mainly the less laborious Kv estimation process and, as far as the MicroFD® is concerned, the possibility of saving time and formulation material when evaluating Rp.
Collapse
|
2
|
Neumann EK, Djambazova KV, Caprioli RM, Spraggins JM. Multimodal Imaging Mass Spectrometry: Next Generation Molecular Mapping in Biology and Medicine. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2401-2415. [PMID: 32886506 PMCID: PMC9278956 DOI: 10.1021/jasms.0c00232] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Imaging mass spectrometry has become a mature molecular mapping technology that is used for molecular discovery in many medical and biological systems. While powerful by itself, imaging mass spectrometry can be complemented by the addition of other orthogonal, chemically informative imaging technologies to maximize the information gained from a single experiment and enable deeper understanding of biological processes. Within this review, we describe MALDI, SIMS, and DESI imaging mass spectrometric technologies and how these have been integrated with other analytical modalities such as microscopy, transcriptomics, spectroscopy, and electrochemistry in a field termed multimodal imaging. We explore the future of this field and discuss forthcoming developments that will bring new insights to help unravel the molecular complexities of biological systems, from single cells to functional tissue structures and organs.
Collapse
|
3
|
Ye M, Crozier KB. Metasurface with metallic nanoantennas and graphene nanoslits for sensing of protein monolayers and sub-monolayers. OPTICS EXPRESS 2020; 28:18479-18492. [PMID: 32680046 DOI: 10.1364/oe.394564] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 05/28/2020] [Indexed: 06/11/2023]
Abstract
Biomolecule sensing plays an important role in both fundamental biological studies and medical diagnostic applications. Infrared (IR) spectroscopy presents opportunities for sensing biomolecules as it allows their fingerprints to be determined by directly measuring their absorption spectra. However, the detection of biomolecules at low concentrations is difficult with conventional IR spectroscopy due to signal-to-noise considerations. This has led to recent interest on the use of nanostructured surfaces to boost the signals from biomolecules in a method termed surface enhanced infrared spectroscopy. So far, efforts have largely involved the use of metallic nanoantennas (which produce large field enhancement) or graphene nanostructures (which produce strong field confinement and provide electrical tunability). Here, we propose a nanostructured surface that combines the large field enhancement of metallic nanoantennas with the strong field confinement and electrical tunability of graphene plasmons. Our device consists of an array of plasmonic nanoantennas and graphene nanoslits on a resonant substrate. We perform systematic electromagnetic simulations to quantify the sensing performance of the proposed device and show that it outperforms designs in which only plasmons from metallic nanoantennas or plasmons from graphene are utilized. These investigations consider the model system of a representative protein-goat anti-mouse immunoglobulin G (IgG) - in monolayer or sub-monolayer form. Our findings provide guidance for future biosensors for the sensitive quantification and identification of biomolecules.
Collapse
|
4
|
Selvaraj R, Vasa NJ, Nagendra SMS, Mizaikoff B. Advances in Mid-Infrared Spectroscopy-Based Sensing Techniques for Exhaled Breath Diagnostics. Molecules 2020; 25:molecules25092227. [PMID: 32397389 PMCID: PMC7249025 DOI: 10.3390/molecules25092227] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 01/05/2023] Open
Abstract
Human exhaled breath consists of more than 3000 volatile organic compounds, many of which are relevant biomarkers for various diseases. Although gas chromatography has been the gold standard for volatile organic compound (VOC) detection in exhaled breath, recent developments in mid-infrared (MIR) laser spectroscopy have led to the promise of compact point-of-care (POC) optical instruments enabling even single breath diagnostics. In this review, we discuss the evolution of MIR sensing technologies with a special focus on photoacoustic spectroscopy, and its application in exhaled breath biomarker detection. While mid-infrared point-of-care instrumentation promises high sensitivity and inherent molecular selectivity, the lack of standardization of the various techniques has to be overcome for translating these techniques into more widespread real-time clinical use.
Collapse
|
5
|
Ritter E, Puskar L, Kim SY, Park JH, Hofmann KP, Bartl F, Hegemann P, Schade U. Féry Infrared Spectrometer for Single-Shot Analysis of Protein Dynamics. J Phys Chem Lett 2019; 10:7672-7677. [PMID: 31763851 DOI: 10.1021/acs.jpclett.9b03099] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Current submillisecond time-resolved broad-band infrared spectroscopy, one of the most frequently used techniques for studying structure-function relationships in life sciences, is typically limited to fast-cycling reactions that can be repeated thousands of times with high frequency. Notably, a majority of chemical and biological processes do not comply with this requirement. For example, the activation of vertebrate rhodopsin, a prototype of many protein receptors in biological organisms that mediate basic functions of life, including vision, smell, and taste, is irreversible. Here we present a dispersive single-shot Féry spectrometer setup that extends such spectroscopy to irreversible and slow-cycling systems by exploiting the unique properties of brilliant synchrotron infrared light combined with an advanced focal plane detector array embedded in a dispersive optical concept. We demonstrate our single-shot method on microbial actinorhodopsin with a slow photocycle and on vertebrate rhodopsin with irreversible activation.
Collapse
|
6
|
Lettow M, Grabarics M, Mucha E, Thomas DA, Polewski Ł, Freyse J, Rademann J, Meijer G, von Helden G, Pagel K. IR action spectroscopy of glycosaminoglycan oligosaccharides. Anal Bioanal Chem 2019; 412:533-537. [PMID: 31853603 PMCID: PMC6992547 DOI: 10.1007/s00216-019-02327-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 11/04/2019] [Accepted: 11/11/2019] [Indexed: 02/06/2023]
Abstract
Glycosaminoglycans (GAGs) are a physio- and pharmacologically highly relevant class of complex saccharides, possessing a linear sequence and strongly acidic character. Their repetitive linear core makes them seem structurally simple at first glance, yet differences in sulfation and epimerization lead to an enormous structural diversity with only a few GAGs having been successfully characterized to date. Recent infrared action spectroscopic experiments on sulfated mono- and disaccharide ions show great promise. Here, we assess the potential of two types of gas-phase action spectroscopy approaches in the range from 1000 to 1800 cm−1 for the structural analysis of complex GAG oligosaccharides. Synthetic tetra- and pentasaccharides were chosen as model compounds for this benchmark study. Utilizing infrared multiple photon dissociation action spectroscopy at room temperature, diagnostic bands are largely unresolved. In contrast, cryogenic infrared action spectroscopy of ions trapped in helium nanodroplets yields resolved infrared spectra with diagnostic features for monosaccharide composition and sulfation pattern. The analysis of GAGs could therefore significantly benefit from expanding the conventional MS-based toolkit with gas-phase cryogenic IR spectroscopy. Graphical abstract ![]()
Collapse
|
7
|
Abstract
Advancement of discrete frequency infrared (DFIR) spectroscopic microscopes in image quality and data throughput are critical to their use for analytical measurements. Here, we report the development and characterization of a point scanning instrument with minimal aberrations and capable of diffraction-limited performance across all fingerprint region wavelengths over arbitrarily large samples. The performance of this system is compared to commercial state of the art Fourier transform infrared (FT-IR) imaging systems. We show that for large samples or smaller set of discrete frequencies, point scanning far exceeds (∼10-100 fold) comparable data acquired with FT-IR instruments. Further we show improvements in image quality using refractive lenses that show significantly improved contrast across the spatial frequency bandwidth. Finally, we introduce the ability to image two tunable frequencies simultaneously using a single detector by means of demodulation to further speed up data acquisition and reduce the impact of scattering. Together, the advancements provide significantly better spectral quality and spatial fidelity than current state of the art imaging systems while promising to make spectral scanning even faster.
Collapse
|
8
|
Ramer G, Ruggeri FS, Levin A, Knowles TPJ, Centrone A. Determination of Polypeptide Conformation with Nanoscale Resolution in Water. ACS NANO 2018; 12:6612-6619. [PMID: 29932670 DOI: 10.1021/acsnano.8b01425] [Citation(s) in RCA: 76] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The folding and acquisition of proteins native structure is central to all biological processes of life. By contrast, protein misfolding can lead to toxic amyloid aggregates formation, linked to the onset of neurodegenerative disorders. To shed light on the molecular basis of protein function and malfunction, it is crucial to access structural information on single protein assemblies and aggregates under native conditions. Yet, current conformation-sensitive spectroscopic methods lack the spatial resolution and sensitivity necessary for characterizing heterogeneous protein aggregates in solution. To overcome this limitation, here we use photothermal-induced resonance to demonstrate that it is possible to acquire nanoscale infrared spectra in water with high signal-to-noise ratio (SNR). Using this approach, we probe supramolecular aggregates of diphenylalanine, the core recognition module of the Alzheimer's β-amyloid peptide, and its derivative Boc-diphenylalanine. We achieve nanoscale resolved IR spectra and maps in air and water with comparable SNR and lateral resolution, thus enabling accurate identification of the chemical and structural state of morphologically similar networks at the single aggregate ( i. e., fibril) level.
Collapse
|
9
|
Yamamoto N, Kawashima N, Kitazaki T, Mori K, Kang H, Nishiyama A, Wada K, Ishimaru I. Ultrasonic standing wave preparation of a liquid cell for glucose measurements in urine by midinfrared spectroscopy and potential application to smart toilets. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-4. [PMID: 29790320 DOI: 10.1117/1.jbo.23.5.050503] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Accepted: 05/01/2018] [Indexed: 05/13/2023]
Abstract
Smart toilets could be used to monitor different components of urine in daily life for early detection of lifestyle-related diseases and prompt provision of treatment. For analysis of biological samples such as urine by midinfrared spectroscopy, thin-film samples like liquid cells are needed because of the strong absorption of midinfrared light by water. Conventional liquid cells or fixed cells are prepared based on the liquid membrane method and solution technique, but these are not quantitative and are difficult to set up and clean. We generated an ultrasonic standing wave reflection plane in a sample and produced an ultrasonic liquid cell. In this cell, the thickness of the optical path length was adjustable, as in the conventional method. The reflection plane could be generated at an arbitrary depth and internal reflected light could be detected by changing the frequency of the ultrasonic wave. We could generate refractive index boundaries using the density difference created by the ultrasonic standing wave. Creation of the reflection plane in the sample was confirmed by optical coherence tomography. Using the proposed method and midinfrared spectroscopy, we discriminated between normal urine samples spiked with glucose at different concentrations and obtained a high correlation coefficient.
Collapse
|
10
|
Bickler MP, Rhodes LJ. Accuracy of detection of carboxyhemoglobin and methemoglobin in human and bovine blood with an inexpensive, pocket-size infrared scanner. PLoS One 2018. [PMID: 29513738 PMCID: PMC5841812 DOI: 10.1371/journal.pone.0193891] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Detecting life-threatening common dyshemoglobins such as carboxyhemoglobin (COHb, resulting from carbon monoxide poisoning) or methemoglobin (MetHb, caused by exposure to nitrates) typically requires a laboratory CO-oximeter. Because of cost, these spectrophotometer-based instrument are often inaccessible in resource-poor settings. The aim of this study was to determine if an inexpensive pocket infrared spectrometer and smartphone (SCiO®Pocket Molecular Sensor, Consumer Physics Ltd., Israel) accurately detects COHb and MetHb in single drops of blood. COHb was created by adding carbon monoxide gas to syringes of heparinized blood human or cow blood. In separate syringes, MetHb was produced by addition of sodium nitrite solution. After incubation and mixing, fractional concentrations of COHb or MetHb were measured using a Radiometer ABL-90 Flex® CO-oximeter. Fifty microliters of the sample were then placed on a microscope slide, a cover slip applied and scanned with the SCiO spectrometer. The spectrograms were used to create simple linear models predicting [COHb] or [MetHb] based on spectrogram maxima, minima and isobestic wavelengths. Our model predicted clinically significant carbon monoxide poisoning (COHb ≥15%) with a sensitivity of 93% and specificity of 88% (regression r2 = 0.63, slope P<0.0001), with a mean bias of 0.11% and an RMS error of 21%. Methemoglobinemia severe enough to cause symptoms (>20% MetHb) was detected with a sensitivity of 100% and specificity of 71% (regression r2 = 0.92, slope P<0.001) mean bias 2.7% and RMS error 21%. Although not as precise as a laboratory CO-oximeter, an inexpensive pocket-sized infrared scanner/smartphone detects >15% COHb or >20% MetHb on a single drop of blood with enough accuracy to be useful as an initial clinical screening. The SCiO and similar relatively low cost spectrometers could be developed as inexpensive diagnostic tools for developing countries.
Collapse
|
11
|
Silva-Perez V, Molero G, Serbin SP, Condon AG, Reynolds MP, Furbank RT, Evans JR. Hyperspectral reflectance as a tool to measure biochemical and physiological traits in wheat. JOURNAL OF EXPERIMENTAL BOTANY 2018; 69:483-496. [PMID: 29309611 PMCID: PMC5853784 DOI: 10.1093/jxb/erx421] [Citation(s) in RCA: 108] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Accepted: 11/06/2017] [Indexed: 05/20/2023]
Abstract
Improving photosynthesis to raise wheat yield potential has emerged as a major target for wheat physiologists. Photosynthesis-related traits, such as nitrogen per unit leaf area (Narea) and leaf dry mass per area (LMA), require laborious, destructive, laboratory-based methods, while physiological traits underpinning photosynthetic capacity, such as maximum Rubisco activity normalized to 25 °C (Vcmax25) and electron transport rate (J), require time-consuming gas exchange measurements. The aim of this study was to assess whether hyperspectral reflectance (350-2500 nm) can be used to rapidly estimate these traits on intact wheat leaves. Predictive models were constructed using gas exchange and hyperspectral reflectance data from 76 genotypes grown in glasshouses with different nitrogen levels and/or in the field under yield potential conditions. Models were developed using half of the observed data with the remainder used for validation, yielding correlation coefficients (R2 values) of 0.62 for Vcmax25, 0.7 for J, 0.81 for SPAD, 0.89 for LMA, and 0.93 for Narea, with bias <0.7%. The models were tested on elite lines and landraces that had not been used to create the models. The bias varied between -2.3% and -5.5% while relative error of prediction was similar for SPAD but slightly greater for LMA and Narea.
Collapse
|
12
|
|
13
|
Popp A, Scheerer D, Heck B, Hauser K. Biomolecular dynamics studied with IR-spectroscopy using quantum cascade lasers combined with nanosecond perturbation techniques. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2017; 181:192-199. [PMID: 28364666 DOI: 10.1016/j.saa.2017.03.053] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 03/17/2017] [Accepted: 03/19/2017] [Indexed: 06/07/2023]
Abstract
Early events of protein folding can be studied with fast perturbation techniques triggering non-equilibrium relaxation dynamics. A nanosecond laser-excited pH-jump or temperature-jump (T-jump) was applied to initiate helix folding or unfolding of poly-l-glutamic acid (PGA). PGA is a homopolypeptide with titratable carboxyl side-chains whose protonation degree determines the PGA conformation. A pH-jump was realized by the photochemical release of protons and induces PGA folding due to protonation of the side-chains. Otherwise, the helical conformation can be unfolded by a T-jump. We operated under conditions where PGA does not aggregate and temperature and pH are the regulatory properties of its conformation. The experiments were performed in such a manner that the folding/unfolding jump proceeded to the same PGA conformation. We quantified the increase/decrease in helicity induced by the pH-/T-jump and demonstrated that the T-jump results in a relatively small change in helical content in contrast to the pH-jump. This is caused by the strong pH-dependence of the PGA conformation. The conformational changes were detected by time-resolved single wavelength IR-spectroscopy using quantum cascade lasers (QCL). We could independently observe the kinetics for α-helix folding and unfolding in PGA by using different perturbation techniques and demonstrate the high sensitivity of time-resolved IR-spectroscopy to study protein folding mechanisms.
Collapse
|
14
|
Sieger M, Kos G, Sulyok M, Godejohann M, Krska R, Mizaikoff B. Portable Infrared Laser Spectroscopy for On-site Mycotoxin Analysis. Sci Rep 2017; 7:44028. [PMID: 28276454 PMCID: PMC5343660 DOI: 10.1038/srep44028] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Accepted: 02/02/2017] [Indexed: 11/09/2022] Open
Abstract
Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B1 affected peanuts at EU regulatory limits of 1250 μg kg-1 and 8 μg kg-1, respectively.
Collapse
|
15
|
Yu X, Liu R, Yu H, Wang J, Wang J, Xu K. Research on the best measurement situation between optical probe and tissue surfaces in non-invasive detection. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:114303. [PMID: 27910541 DOI: 10.1063/1.4967866] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Near-infrared spectroscopy is often used for the non-invasive detection of composition in the human body, such as that of blood glucose and haemoglobin, due to its high penetration depth into tissues. Although it is feasible to position the optical probe precisely, contact situation between probe and human tissues is a difficult problem to determine because of physiological tremor and mechanical performance of bio-soft tissue. Here, we proposed a novel estimation method for the situation between the optical probe and tissue surfaces based on the dynamic auto-correlation matrix of two-dimensional correlation spectroscopy (2DCOS) and radar chart. The diffuse reflectance spectra from the left palm of 4 healthy volunteers were collected while the optical probe gradually approached and pressed bio-tissues with a custom-design controlling device. 2DCOS in the wavelength with lower absorption (1000-1400 nm) was calculated under the perturbation of relative-distance and contact pressure between the optical probe and tissue surface. The synchronous 2DCOS showed that the surface reflection and diffuse reflectance were greatly affected by the contact conditions in 1100 nm, 1220 nm, and 1300 nm. Then the dynamic auto-correlation matrix of 2DCOS was established for the adjacent spectra, and the significant difference wavelengths were used to build radar charts to determine the critical contact situation visually. Results showed that the maximum variations of dynamic auto-correlation matrix appeared at near 1300 nm, and the relative distance between the probe and tissue corresponding to the critical contact state can be easily observed with radar charts with 0.25 mm uncertainty, which was consistent with the self-feeling of each volunteer. So this method can be applied to exactly determine the optimal measurement status for the non-invasive body composition detection in vivo. It is important for the design of human-machine interface and the accuracy improvement of body composition measurements.
Collapse
|
16
|
Billard H, Simon L, Desnots E, Sochard A, Boscher C, Riaublanc A, Alexandre-Gouabau MC, Boquien CY. Calibration Adjustment of the Mid-infrared Analyzer for an Accurate Determination of the Macronutrient Composition of Human Milk. J Hum Lact 2016; 32:NP19-27. [PMID: 26037506 DOI: 10.1177/0890334415588513] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Accepted: 05/03/2015] [Indexed: 11/15/2022]
Abstract
BACKGROUND Human milk composition analysis seems essential to adapt human milk fortification for preterm neonates. The Miris human milk analyzer (HMA), based on mid-infrared methodology, is convenient for a unique determination of macronutrients. However, HMA measurements are not totally comparable with reference methods (RMs). OBJECTIVE The primary aim of this study was to compare HMA results with results from biochemical RMs for a large range of protein, fat, and carbohydrate contents and to establish a calibration adjustment. METHODS Human milk was fractionated in protein, fat, and skim milk by covering large ranges of protein (0-3 g/100 mL), fat (0-8 g/100 mL), and carbohydrate (5-8 g/100 mL). For each macronutrient, a calibration curve was plotted by linear regression using measurements obtained using HMA and RMs. RESULTS For fat, 53 measurements were performed, and the linear regression equation was HMA = 0.79RM + 0.28 (R(2) = 0.92). For true protein (29 measurements), the linear regression equation was HMA = 0.9RM + 0.23 (R(2) = 0.98). For carbohydrate (15 measurements), the linear regression equation was HMA = 0.59RM + 1.86 (R(2) = 0.95). A homogenization step with a disruptor coupled to a sonication step was necessary to obtain better accuracy of the measurements. Good repeatability (coefficient of variation < 7%) and reproducibility (coefficient of variation < 17%) were obtained after calibration adjustment. CONCLUSION New calibration curves were developed for the Miris HMA, allowing accurate measurements in large ranges of macronutrient content. This is necessary for reliable use of this device in individualizing nutrition for preterm newborns.
Collapse
|
17
|
Bensaid S, Kachenoura A, Costet N, De Ledinghen V, Vergniol J, Laine F, Turlin B, Tariel H, Senhadji L. Early diagnosis of NAFLD-NASH transition using mid infrared spectroscopy. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:3602-3605. [PMID: 28269075 DOI: 10.1109/embc.2016.7591507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Non-alcoholic fatty liver disease (NAFLD) is defined as an excessive accumulation of fat in the liver in the absence of excessive drinking of alcohol. Initially considered as benign and self-limited, NAFLD may progress to the malignant stage of non-alcoholic steatohepatitis (NASH) characterized by degenerate hepatocellular ballooning and lobular inflammation. NASH can lead to hepatic fibrosis and ultimately to cirrhosis and hepatocellular carcinoma. Unfortunately, the transition from NAFLD to NASH is difficult to detect so far. In this paper, we propose to evaluate the characterization of NASH using mid infrared fiber evanescent wave spectroscopy on blood serum. We used an heuristic variable selection method and a generalized linear model to classify NAFLD and NASH spectra. The obtained results proved that this technique is a promising non-invasive and simple diagnosis tool for NASH.
Collapse
|
18
|
Chitnis D, Airantzis D, Highton D, Williams R, Phan P, Giagka V, Powell S, Cooper RJ, Tachtsidis I, Smith M, Elwell CE, Hebden JC, Everdell N. Towards a wearable near infrared spectroscopic probe for monitoring concentrations of multiple chromophores in biological tissue in vivo. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:065112. [PMID: 27370501 PMCID: PMC4957669 DOI: 10.1063/1.4954722] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
The first wearable multi-wavelength technology for functional near-infrared spectroscopy has been developed, based on a custom-built 8-wavelength light emitting diode (LED) source. A lightweight fibreless probe is designed to monitor changes in the concentrations of multiple absorbers (chromophores) in biological tissue, the most dominant of which at near-infrared wavelengths are oxyhemoglobin and deoxyhemoglobin. The use of multiple wavelengths enables signals due to the less dominant chromophores to be more easily distinguished from those due to hemoglobin and thus provides more complete and accurate information about tissue oxygenation, hemodynamics, and metabolism. The spectroscopic probe employs four photodiode detectors coupled to a four-channel charge-to-digital converter which includes a charge integration amplifier and an analogue-to-digital converter (ADC). Use of two parallel charge integrators per detector enables one to accumulate charge while the other is being read out by the ADC, thus facilitating continuous operation without dead time. The detector system has a dynamic range of about 80 dB. The customized source consists of eight LED dies attached to a 2 mm × 2 mm substrate and encapsulated in UV-cured epoxy resin. Switching between dies is performed every 20 ms, synchronized to the detector integration period to within 100 ns. The spectroscopic probe has been designed to be fully compatible with simultaneous electroencephalography measurements. Results are presented from measurements on a phantom and a functional brain activation study on an adult volunteer, and the performance of the spectroscopic probe is shown to be very similar to that of a benchtop broadband spectroscopy system. The multi-wavelength capabilities and portability of this spectroscopic probe will create significant opportunities for in vivo studies in a range of clinical and life science applications.
Collapse
|
19
|
Greetham GM, Donaldson PM, Nation C, Sazanovich IV, Clark IP, Shaw DJ, Parker AW, Towrie M. A 100 kHz Time-Resolved Multiple-Probe Femtosecond to Second Infrared Absorption Spectrometer. APPLIED SPECTROSCOPY 2016; 70:645-653. [PMID: 26887988 DOI: 10.1177/0003702816631302] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2015] [Accepted: 08/05/2015] [Indexed: 06/05/2023]
Abstract
We present a dual-amplifier laser system for time-resolved multiple-probe infrared (IR) spectroscopy based on the ytterbium potassium gadolinium tungstate (Yb:KGW) laser medium. Comparisons are made between the ytterbium-based technology and titanium sapphire laser systems for time-resolved IR spectroscopy measurements. The 100 kHz probing system provides new capability in time-resolved multiple-probe experiments, as more information is obtained from samples in a single experiment through multiple-probing. This method uses the high repetition-rate probe pulses to repeatedly measure spectra at 10 µs intervals following excitation allowing extended timescales to be measured routinely along with ultrafast data. Results are presented showing the measurement of molecular dynamics over >10 orders of magnitude in timescale, out to 20 ms, with an experimental time response of <200 fs. The power of multiple-probing is explored through principal component analysis of repeating probe measurements as a novel method for removing noise and measurement artifacts.
Collapse
|
20
|
Kang S, Hong SY. Assessing Seasonal and Inter-Annual Variations of Lake Surface Areas in Mongolia during 2000-2011 Using Minimum Composite MODIS NDVI. PLoS One 2016; 11:e0151395. [PMID: 27007233 PMCID: PMC4805288 DOI: 10.1371/journal.pone.0151395] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Accepted: 02/26/2016] [Indexed: 11/24/2022] Open
Abstract
A minimum composite method was applied to produce a 15-day interval normalized difference vegetation index (NDVI) dataset from Moderate Resolution Imaging Spectroradiometer (MODIS) daily 250 m reflectance in the red and near-infrared bands. This dataset was applied to determine lake surface areas in Mongolia. A total of 73 lakes greater than 6.25 km2in area were selected, and 28 of these lakes were used to evaluate detection errors. The minimum composite NDVI showed a better detection performance on lake water pixels than did the official MODIS 16-day 250 m NDVI based on a maximum composite method. The overall lake area detection performance based on the 15-day minimum composite NDVI showed -2.5% error relative to the Landsat-derived lake area for the 28 evaluated lakes. The errors increased with increases in the perimeter-to-area ratio but decreased with lake size over 10 km2. The lake area decreased by -9.3% at an annual rate of -53.7 km2 yr-1 during 2000 to 2011 for the 73 lakes. However, considerable spatial variations, such as slight-to-moderate lake area reductions in semi-arid regions and rapid lake area reductions in arid regions, were also detected. This study demonstrated applicability of MODIS 250 m reflectance data for biweekly monitoring of lake area change and diagnosed considerable lake area reduction and its spatial variability in arid and semi-arid regions of Mongolia. Future studies are required for explaining reasons of lake area changes and their spatial variability.
Collapse
|
21
|
Guimbaud C, Noel C, Chartier M, Catoire V, Blessing M, Gourry JC, Robert C. A quantum cascade laser infrared spectrometer for CO2 stable isotope analysis: Field implementation at a hydrocarbon contaminated site under bio-remediation. J Environ Sci (China) 2016; 40:60-74. [PMID: 26969546 DOI: 10.1016/j.jes.2015.11.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Revised: 10/07/2015] [Accepted: 11/27/2015] [Indexed: 06/05/2023]
Abstract
Real-time methods to monitor stable isotope ratios of CO2 are needed to identify biogeochemical origins of CO2 emissions from the soil-air interface. An isotope ratio infra-red spectrometer (IRIS) has been developed to measure CO2 mixing ratio with δ(13)C isotopic signature, in addition to mixing ratios of other greenhouse gases (CH4, N2O). The original aspects of the instrument as well as its precision and accuracy for the determination of the isotopic signature δ(13)C of CO2 are discussed. A first application to biodegradation of hydrocarbons is presented, tested on a hydrocarbon contaminated site under aerobic bio-treatment. CO2 flux measurements using closed chamber method is combined with the determination of the isotopic signature δ(13)C of the CO2 emission to propose a non-intrusive method to monitor in situ biodegradation of hydrocarbons. In the contaminated area, high CO2 emissions have been measured with an isotopic signature δ(13)C suggesting that CO2 comes from petroleum hydrocarbon biodegradation. This first field implementation shows that rapid and accurate measurement of isotopic signature of CO2 emissions is particularly useful in assessing the contribution of contaminant degradation to the measured CO2 efflux and is promising as a monitoring tool for aerobic bio-treatment.
Collapse
|
22
|
Ghosh A, Serrano AL, Oudenhoven TA, Ostrander JS, Eklund EC, Blair AF, Zanni MT. Experimental implementations of 2D IR spectroscopy through a horizontal pulse shaper design and a focal plane array detector. OPTICS LETTERS 2016; 41:524-7. [PMID: 26907414 PMCID: PMC5301998 DOI: 10.1364/ol.41.000524] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Aided by advances in optical engineering, two-dimensional infrared spectroscopy (2D IR) has developed into a promising method for probing structural dynamics in biophysics and material science. We report two new advances for 2D IR spectrometers. First, we report a fully reflective and totally horizontal pulse shaper, which significantly simplifies alignment. Second, we demonstrate the applicability of mid-IR focal plane arrays (FPAs) as suitable detectors in 2D IR experiments. FPAs have more pixels than conventional linear arrays and can be used to multiplex optical detection. We simultaneously measure the spectra of a reference beam, which improves the signal-to-noise by a factor of 4; and two additional beams that are orthogonally polarized probe pulses for 2D IR anisotropy experiments.
Collapse
|
23
|
Bromenshenk JJ, Henderson CB, Seccomb RA, Welch PM, Debnam SE, Firth DR. Bees as Biosensors: Chemosensory Ability, Honey Bee Monitoring Systems, and Emergent Sensor Technologies Derived from the Pollinator Syndrome. BIOSENSORS-BASEL 2015; 5:678-711. [PMID: 26529030 PMCID: PMC4697140 DOI: 10.3390/bios5040678] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Revised: 09/09/2015] [Accepted: 10/05/2015] [Indexed: 01/28/2023]
Abstract
This review focuses on critical milestones in the development path for the use of bees, mainly honey bees and bumble bees, as sentinels and biosensors. These keystone species comprise the most abundant pollinators of agro-ecosystems. Pollinating 70%–80% of flowering terrestrial plants, bees and other insects propel the reproduction and survival of plants and themselves, as well as improve the quantity and quality of seeds, nuts, and fruits that feed birds, wildlife, and us. Flowers provide insects with energy, nutrients, and shelter, while pollinators are essential to global ecosystem productivity and stability. A rich and diverse milieu of chemical signals establishes and maintains this intimate partnership. Observations of bee odor search behavior extend back to Aristotle. In the past two decades great strides have been made in methods and instrumentation for the study and exploitation of bee search behavior and for examining intra-organismal chemical communication signals. In particular, bees can be trained to search for and localize sources for a variety of chemicals, which when coupled with emerging tracking and mapping technologies create novel potential for research, as well as bee and crop management.
Collapse
|
24
|
Salpin JY, Scuderi D. Structure of protonated thymidine characterized by infrared multiple photon dissociation and quantum calculations. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2015; 29:1898-1904. [PMID: 26411511 DOI: 10.1002/rcm.7296] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 07/23/2015] [Accepted: 07/29/2015] [Indexed: 06/05/2023]
Abstract
RATIONALE Many fundamental studies are motivated by the probable relationship between the presence of rare enol tautomers of nucleobases and point mutation developing during nucleic acid replication. The evaluation of the tautomeric behaviour of nucleobases is therefore of fundamental importance. This can be probed in the gas phase by combining action spectroscopy and mass spectrometry. METHODS Experimental Infrared Multiple Photon Dissociation spectra in the fingerprint region of electrospray-generated and subsequently selected ions were recorded at the CLIO free electron laser (FEL) facility, by coupling the FEL to a quadrupole ion trap, and compared to calculated harmonic vibrational infrared spectra of the different low-lying isomers computed at the B3LYP/6-31++G(d,p) level. Relative energies were refined using the extended basis set 6-311++G(3df,2p). RESULTS The Density Functional Theory (DFT) study shows that, as for protonated thymine, the global energy minimum of protonated thymidine corresponds to an enol tautomer, whose infrared absorption spectrum is found to be in very good agreement with the experimental IRMPD spectrum. A very weak IRMPD signal observed at ~1780 cm(-1) is very likely the signature of an oxo tautomer. Consequently, as for thymine, protonated thymidine generated by electrospray corresponds to a mixture of at least two tautomeric forms. CONCLUSIONS Tautomerization can be characterized by IRMPD spectroscopy. Interestingly, the dominant enolic tautomeric form(s) presently observed cannot be directly generated from the most stable neutral tautomer of the thymine residue.
Collapse
|
25
|
Yin K, Li L, Yao J, Zhang B, Hou J. Over 100 W ultra-flat broadband short-wave infrared supercontinuum generation in a thulium-doped fiber amplifier. OPTICS LETTERS 2015; 40:4787-4790. [PMID: 26469620 DOI: 10.1364/ol.40.004787] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
An ultra-flat high-power short-wave infrared super-continuum (SC) source generated in an all-fiber thulium-doped fiber amplifier (TDFA) is reported. The SC had a high-spectral flatness with a 10 dB spectral bandwidth spanning from 1970 to 2431 nm and a power spectral density >23 dBm/nm. The output SC beam had Gaussian-shape profiles with a maximum average power of 101.6 W, a SC pulse repetition rate of 2 MHz, and a temporal duration of ∼5 ns. Benefiting from the high duty cycle of the 2 μm seed pulses, the power conversion efficiency from the 793 nm pump light to the maximal SC output power in the TDFA was as high as 35.4%, and the slope efficiency of the TDFA was linearly fitted to be 36.5%. Long-term high-power operation of the SC source showed its outstanding temporal stability. To the best of the authors' knowledge, the results obtained in this Letter represent a new power record for ultra-flat SC in the short-wave infrared region.
Collapse
|