426
|
Gao D, Wang DD, Zhang Q, Yang FQ, Xia ZN, Zhang QH, Yuan CS. In Vivo Selective Capture and Rapid Identification of Luteolin and Its Metabolites in Rat Livers by Molecularly Imprinted Solid-Phase Microextraction. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2017; 65:1158-1166. [PMID: 28111945 DOI: 10.1021/acs.jafc.6b05269] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A method based on molecularly imprinted solid-phase microextraction (MIP-SPME) coupled with liquid chromatography-quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) was developed for the detection of luteolin and its metabolites in vivo. The MIP-SPME fibers were first fabricated by dopamine and silane, and then luteolin MIPs-coated fibers were successfully prepared using luteolin, acrylamide (AM), and ethylene glycol dimethacrylate (EGDMA) as the template, functional monomer and cross-linker, respectively. The characterizations of polymers were analyzed by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), and the Brunauer-Emmett-Teller method (BET). The properties involving adsorption and selective experiments were evaluated, and these results revealed that MIP fibers presented high adsorption capacity and selectivity to luteolin. Furthermore, the developed MIP-SPME coupled with the LC-QTOF-MS/MS method was adopted to capture and identify luteolin and its metabolites in rat livers in vivo, and eventually, apigenin, chrysoeriol, and diosmetin were rapidly identified as metabolites.
Collapse
|
427
|
Vila M, Celeiro M, Lamas JP, Garcia-Jares C, Dagnac T, Llompart M. Simultaneous in-vial acetylation solid-phase microextraction followed by gas chromatography tandem mass spectrometry for the analysis of multiclass organic UV filters in water. JOURNAL OF HAZARDOUS MATERIALS 2017; 323:45-55. [PMID: 27421980 DOI: 10.1016/j.jhazmat.2016.06.056] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Revised: 06/15/2016] [Accepted: 06/27/2016] [Indexed: 06/06/2023]
Abstract
UV filters are a class of emerging contaminants that are widely used in personal care products (PCPs) and that can be detected at low concentrations in the aquatic environment (ngL-1). Sensitive modern analytical methods are then mandatory to accurately analyze them. A methodology based on solid-phase-microextraction (SPME), considered as a 'Green Chemistry' technique, followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the simultaneous analysis of 14 UV filters of different chemical nature in environmental and recreational waters. In-vial low-cost derivatization was carried out to improve chromatographic performance of phenolic compounds. The extraction parameters (fiber coating, extraction mode, and salt addition) were optimized by means of experimental designs in order to achieve reliable conditions. Finally, the SPME-GC-MS/MS method was validated in terms of linearity, accuracy and precision with LODs in the low ngL-1 level. Its application to the analysis of 28 different samples including sea, river, spa, swimming pool, and aquapark waters, enabled the detection of 11 target UV filters at concentration levels up to 540μgL-1, highlighting the presence of OCR in all analyzed samples and of 2EHMC (proposed to be considered as priority pollutant) in 79% of them.
Collapse
|
428
|
García-Vico L, Belaj A, Sánchez-Ortiz A, Martínez-Rivas JM, Pérez AG, Sanz C. Volatile Compound Profiling by HS-SPME/GC-MS-FID of a Core Olive Cultivar Collection as a Tool for Aroma Improvement of Virgin Olive Oil. Molecules 2017; 22:molecules22010141. [PMID: 28098834 PMCID: PMC6155863 DOI: 10.3390/molecules22010141] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 12/29/2016] [Accepted: 01/10/2017] [Indexed: 11/25/2022] Open
Abstract
Virgin olive oil (VOO) is the only food product requiring official sensory analysis to be classified in commercial categories, in which the evaluation of the aroma plays a very important role. The selection of parents, with the aim of obtaining new cultivars with improved oil aroma, is of paramount importance in olive breeding programs. We have assessed the volatile fraction by headspace-solid-phase microextraction/gas chromatography-mass spectrometry-flame ionization detection (HS-SPME/GC-MS-FID) and the deduced aroma properties of VOO from a core set of olive cultivars (Core-36) which possesses most of the genetic diversity found in the World Olive Germplasm Collection (IFAPA Alameda del Obispo) located in Cordoba, Spain. The VOO volatile fractions of Core-36 cultivars display a high level of variability. It is mostly made of compounds produced from polyunsaturated fatty acids through the lipoxygenase pathway, which confirms to be a general characteristic of the olive species (Olea europaea L.). The main group of volatile compounds in the oils was six straight-chain carbon compounds derived from linolenic acid, some of them being the main contributors to the aroma of the olive oils according to their odor activity values (OAV). The high level of variability found for the volatile fraction of the oils from Core-36 and, therefore, for the aroma odor notes, suggest that this core set may be a very useful tool for the choice of optimal parents in olive breeding programs in order to raise new cultivars with improved VOO aroma.
Collapse
|
429
|
Bahrani S, Ghaedi M, Mansoorkhani MJK, Asfaram A, Bazrafshan AA, Purkait MK. Ultrasonic assisted dispersive solid-phase microextraction of Eriochrome Cyanine R from water sample on ultrasonically synthesized lead (II) dioxide nanoparticles loaded on activated carbon: Experimental design methodology. ULTRASONICS SONOCHEMISTRY 2017; 34:317-324. [PMID: 27773252 DOI: 10.1016/j.ultsonch.2016.06.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 06/01/2016] [Accepted: 06/01/2016] [Indexed: 06/06/2023]
Abstract
The present research focus on designing an appropriate dispersive solid-phase microextraction (UA-DSPME) for preconcentration and determination of Eriochrome Cyanine R (ECR) in aqueous solutions with aid of sonication using lead (II) dioxide nanoparticles loaded on activated carbon (PbO-NPs-AC). This material was fully identified with XRD and SEM. Influence of pH, amounts of sorbent, type and volume of eluent, and sonication time on response properties were investigated and optimized by central composite design (CCD) combined with surface response methodology using STATISTICA. Among different solvents, dimethyl sulfoxide (DMSO) was selected as an efficient eluent, which its combination by present nanoparticles and application of ultrasound waves led to enhancement in mass transfer. The predicted maximum extraction (100%) under the optimum conditions of the process variables viz. pH 4.5, eluent 200μL, adsorbent dosage 2.5mg and 5min sonication was close to the experimental value (99.50%). at optimum conditions some experimental features like wide 5-2000ngmL-1 ECR, low detection limit (0.43ngmL-1, S/N=3:1) and good repeatability and reproducibility (relative standard deviation, <5.5%, n=12) indicate versatility in successful applicability of present method for real sample analysis. Investigation of accuracy by spiking known concentration of ECR over 200-600ngmL-1 gave mean recoveries from 94.850% to 101.42% under optimal conditions. The procedure was also applied for the pre-concentration and subsequent determination of ECR in tap and waste waters.
Collapse
|
430
|
Pooralhossini J, Ghaedi M, Zanjanchi MA, Asfaram A. The choice of ultrasound assisted extraction coupled with spectrophotometric for rapid determination of gallic acid in water samples: Central composite design for optimization of process variables. ULTRASONICS SONOCHEMISTRY 2017; 34:692-699. [PMID: 27773296 DOI: 10.1016/j.ultsonch.2016.07.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 07/07/2016] [Accepted: 07/07/2016] [Indexed: 06/06/2023]
Abstract
A sensitive procedure namely ultrasound-assisted (UA) coupled dispersive nano solid-phase microextraction spectrophotometry (DNSPME-UV-Vis) was designed for preconcentration and subsequent determination of gallic acid (GA) from water samples, while the detailed of composition and morphology and also purity and structure of this new sorbent was identified by techniques like field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD) and Energy-dispersive X-ray spectroscopy (EDX) techniques. Among conventional parameters viz. pH, amount of sorbent, sonication time and volume of elution solvent based on Response Surface Methodology (RSM) and central composite design according to statistics based contour the best operational conditions was set at pH of 2.0; 1.5mg sorbent, 4.0min sonication and 150μL ethanol. Under these pre-qualified conditions the method has linear response over wide concentration range of 15-6000ngmL-1 with a correlation coefficient of 0.9996. The good figure of merits like acceptable LOD (S/N=3) and LOQ (S/N=10) with numerical value of 2.923 and 9.744ngmL-1, respectively and relative recovery between 95.54 and 100.02% show the applicability and efficiency of this method for real samples analysis with RSDs below 6.0%. Finally the method with good performance were used for monitoring under study analyte in various real samples like tap, river and mineral waters.
Collapse
|
431
|
Asfaram A, Ghaedi M, Dashtian K. Ultrasound assisted combined molecularly imprinted polymer for selective extraction of nicotinamide in human urine and milk samples: Spectrophotometric determination and optimization study. ULTRASONICS SONOCHEMISTRY 2017; 34:640-650. [PMID: 27773291 DOI: 10.1016/j.ultsonch.2016.06.018] [Citation(s) in RCA: 59] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2016] [Revised: 06/14/2016] [Accepted: 06/15/2016] [Indexed: 06/06/2023]
Abstract
Ultrasound-assisted dispersive solid phase microextraction followed by UV-vis spectrophotometer (UA-DSPME-UV-vis) was designed for extraction and preconcentration of nicotinamide (vitamin B3) by HKUST-1 metal organic framework (MOF) based molecularly imprinted polymer (MIP). This new material was characterized by FTIR and FE-SEM techniques. The preliminary Plackett-Burman design was used for screening and subsequently the central composite design justifies significant terms and possible construction of mathematical equation which give the individual and cooperative contribution of variables like HKUST-1-MOF-NA-MIP mass, sonication time, temperature, eluent volume, pH and vortex time. Accordingly the optimum condition was set as: 2.0mg HKUST-1-MOF-NA-MIP, 200μL eluent and 5.0min sonication time in center points other variables were determined as the best conditions to reach the maximum recovery of the analyte. The UA-DSPME-UV-vis method performances like excellent linearity (LR), limits of detection (LOD), limits of quantification of 10-5000μgL-1 with R2 of 0.99, LOD (1.96ngmL-1), LOQ (6.53μgL-1), respectively show successful and accurate applicability of the present method for monitoring analytes with within- and between-day precision of 0.96-3.38%. The average absolute recoveries of the nicotinamide extracted from the urine, milk and water samples were 95.85-101.27%.
Collapse
|
432
|
Babaee S, Daneshfar A, Khezeli T. Determination of carboxylic acids in non-alcoholic beer samples by an ultrasonic-assisted dispersive micro-solid phase extraction based on Ni/Cu-Al layered double hydroxide nanocomposites followed by gas chromatography. ULTRASONICS SONOCHEMISTRY 2017; 34:847-855. [PMID: 27773312 DOI: 10.1016/j.ultsonch.2016.07.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2016] [Revised: 07/27/2016] [Accepted: 07/27/2016] [Indexed: 06/06/2023]
Abstract
Magnetically separable layered double hydroxide Ni/CuAl-LDH nanocomposites were synthesized and employed as ultrasonic-assisted dispersive micro-solid phase extraction (UA-D-μSPE) sorbent to extract several carboxylic acids (namely propionic, butyric, pentanoic, hexanoic, heptanoic, octanoic, and decanoic) from non-alcoholic beer samples. Ni/CuAl-LDH sorbent was characterized by Fourier transform-infrared (FTIR) spectroscopy, transmission electron microscopy (TEM), and vibrating sample magnetometry (VSM). Effective variables such as amount of sorbent (mg), pH and ionic strength of sample solution, volume of eluent solvent (μL), vortex, and ultrasonic times (min) were investigated via fractional factorial design (FFD). The significant variables were optimized by a Box-Behnken design and combined by a desirability function (DF). Under optimized conditions, the calibration graphs of analytes were linear in a concentration range of 0.05-100μg/mL and had correlation coefficients more than 0.997. The limits of detection and quantification were in the ranges of 16-40μg/L and 53-133μg/L, respectively. This procedure was successfully employed in the determination of target analytes in spiked beer samples, and the relative mean recoveries ranged from 87 to 110%.
Collapse
|
433
|
Zhu F, Pan Z, Hong C, Wang W, Chen X, Xue Z, Yao Y. Analysis of volatile organic compounds in compost samples: A potential tool to determine appropriate composting time. WASTE MANAGEMENT (NEW YORK, N.Y.) 2016; 58:98-106. [PMID: 27346593 DOI: 10.1016/j.wasman.2016.06.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Revised: 06/12/2016] [Accepted: 06/13/2016] [Indexed: 06/06/2023]
Abstract
Changes in volatile organic compound contents in compost samples during pig manure composting were studied using a headspace, solid-phase micro-extraction method (HS-SPME) followed by gas chromatography with mass spectrometric detection (GC/MS). Parameters affecting the SPME procedure were optimized as follows: the coating was carbon molecular sieve/polydimethylsiloxane (CAR/PDMS) fiber, the temperature was 60°C and the time was 30min. Under these conditions, 87 compounds were identified from 17 composting samples. Most of the volatile components could only be detected before day 22. However, benzenes, alkanes and alkenes increased and eventually stabilized after day 22. Phenol and acid substances, which are important factors for compost quality, were almost undetectable on day 39 in natural compost (NC) samples and on day 13 in maggot-treated compost (MC) samples. Our results indicate that the approach can be effectively used to determine the composting times by analysis of volatile substances in compost samples. An appropriate composting time not only ensures the quality of compost and reduces the loss of composting material but also reduces the generation of hazardous substances. The appropriate composting times for MC and NC were approximately 22days and 40days, respectively, during the summer in Zhejiang.
Collapse
|
434
|
Chen L, Huang X. Sensitive Monitoring of Fluoroquinolones in Milk and Honey Using Multiple Monolithic Fiber Solid-Phase Microextraction Coupled to Liquid Chromatography Tandem Mass Spectrometry. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2016; 64:8684-8693. [PMID: 27787985 DOI: 10.1021/acs.jafc.6b03965] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In the present study, a new multiple monolithic fiber solid-phase microextraction (MMF-SPME) based on poly(apronal-co-divinylbenzene/ethylenedimethacrylate) monolith (APDE) was synthesized. The effect of the preparation parameters of APED on extraction efficiency was studied thoroughly. The combination of APDE/MMF-SPME with high-performance liquid chromatography tandem mass spectrometry detection (HPLC/MS-MS) was developed for sensitive monitoring of ultratrace fluoroquinolones (FQs) in foodstuffs, including milk and honey samples. Under the optimized experimental conditions, the limits of detection (S/N = 3) for the targeted FQs ranged from 0.0019 to 0.018 μg/kg in milk and 0.0010 to 0.0028 μg/kg in honey. The relative standard deviations (RSDs) for method reproducibility were less than 9% in all samples. The established method was successfully applied for the monitoring of FQs residues in milk and honey samples with the recoveries between 74.5% and 116% (RSDs were in the range 0.9-9.5%). In comparison to previous methods, the developed APDE/MMF-SPME-HPLC/MS-MS showed some merits, including satisfactory sensitivity, simplicity, high cost-effectiveness, and low consumption of organic solvent.
Collapse
|
435
|
Li L, Wu M, Feng Y, Zhao F, Zeng B. Doping of three-dimensional porous carbon nanotube-graphene-ionic liquid composite into polyaniline for the headspace solid-phase microextraction and gas chromatography determination of alcohols. Anal Chim Acta 2016; 948:48-54. [PMID: 27871609 DOI: 10.1016/j.aca.2016.11.020] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2016] [Revised: 10/26/2016] [Accepted: 11/04/2016] [Indexed: 12/25/2022]
Abstract
In this work, ionic liquid (IL, i.e. 1-hydroxyethyl-3-methylimidazolium tetrafluoroborate), carboxyl multiwall carbon nanotubes (MWCNTs) and reduced graphene oxide (rGO) were used to prepare three-dimensional porous material (MWCNTs-rGO-IL) by one-step self-assembly, then it was co-electrodeposited with polyaniline (PANI) on stainless steel wires by cyclic voltammetry. The resulting coating (PANI-MWCNTs-rGO-IL) was characterized by using FT-IR and scanning electron microscopy etc, and it showed porous structure and had high thermal stability. Furthermore, it was found to be very suitable for the headspace solid-phase microextraction of alcohols (i.e. octanol, nonanol, geraniol, decanol, undecanol and dodecanol). By coupling with gas chromatography, wide linear ranges and low limits of detection (i.e. 2.2-28.3 ng L-1) were obtained for the alcohols. The coating also presented good repeatability and reproducibility; the relative standard deviations for intra-fiber and fiber-to-fiber were less than 5.6% (n = 5) and 7.0% (n = 5) respectively. In addition, the proposed method was successfully applied to the determination of alcohols in tea drinks, and the recoveries for standards added were 85.6-114%.
Collapse
|
436
|
Deasy W, Shepherd T, Alexander CJ, Birch ANE, Evans KA. Field-based Evaluation of a Novel SPME-GC-MS Method for Investigation of Below-ground Interaction between Brassica Roots and Larvae of Cabbage Root Fly, Delia radicum L. PHYTOCHEMICAL ANALYSIS : PCA 2016; 27:343-353. [PMID: 27689319 DOI: 10.1002/pca.2634] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 05/03/2016] [Accepted: 05/19/2016] [Indexed: 06/06/2023]
Abstract
INTRODUCTION Collection of volatiles from plant roots poses technical challenges due to difficulties accessing the soil environment without damaging the roots. OBJECTIVES To validate a new non-invasive method for passive sampling of root volatiles in situ, from plants grown under field conditions, using solid phase micro-extraction (SPME). METHODS SPME fibres were inserted into perforated polytetrafluoroethene (PTFE) tubes positioned in the soil next to broccoli plants for collection of root volatiles pre- and post-infestation with Delia radicum larvae. After sample analysis by gas chromatography-mass spectrometry (GC-MS), principal component analysis (PCA) was applied to determine differences in the profiles of volatiles between samples. RESULTS GC-MS analysis revealed that this method can detect temporal changes in root volatiles emitted before and after Delia radicum damage. PCA showed that samples collected pre- and post-infestation were compositionally different due to the presence of root volatiles induced by D. radicum feeding. Sulphur containing compounds, in particular, accounted for the differences observed. Root volatiles emission patterns post-infestation are thought to follow the feeding and developmental progress of larvae. CONCLUSION This study shows that volatiles released by broccoli roots can be collected in situ using SPME fibres within perforated PTFE tubes under field conditions. Plants damaged by Delia radicum larvae could be distinguished from plants sampled pre-infestation and soil controls on the basis of larval feeding-induced sulphur-containing volatiles. These results show that this new method is a powerful tool for non-invasive sampling of root volatiles below-ground. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
|
437
|
Deasy W, Shepherd T, Alexander CJ, Birch ANE, Evans KA. Development and Validation of a SPME-GC-MS Method for In situ Passive Sampling of Root Volatiles from Glasshouse-Grown Broccoli Plants Undergoing Below-Ground Herbivory by Larvae of Cabbage Root Fly, Delia radicum L. PHYTOCHEMICAL ANALYSIS : PCA 2016; 27:375-393. [PMID: 27687886 DOI: 10.1002/pca.2637] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 06/27/2016] [Accepted: 07/01/2016] [Indexed: 05/20/2023]
Abstract
INTRODUCTION Research on plant root chemical ecology has benefited greatly from recent developments in analytical chemistry. Numerous reports document techniques for sampling root volatiles, although only a limited number describe in situ collection. OBJECTIVES To demonstrate a new method for non-invasive in situ passive sampling using solid phase micro extraction (SPME), from the immediate vicinity of growing roots. METHODS SPME fibres inserted into polyfluorotetrafluoroethylene (PTFE) sampling tubes located in situ which were either perforated, covered with stainless steel mesh or with microporous PTFE tubing, were used for non-invasive sub-surface sampling of root volatiles from glasshouse-grown broccoli. Sampling methods were compared with above surface headspace collection using Tenax TA. The roots were either mechanically damaged or infested with Delia radicum larvae. Principal component analysis (PCA) was used to investigate the effect of damage on the composition of volatiles released by broccoli roots. RESULTS Analyses by gas chromatography-mass spectrometry (GC-MS) with SPME and automated thermal desorption (ATD) confirmed that sulphur compounds, showing characteristic temporal emission patterns, were the principal volatiles released by roots following insect larval damage. Use of SPME with in situ perforated PTFE sampling tubes was the most robust method for out-of-lab sampling. CONCLUSION This study describes a new method for non-invasive passive sampling of volatiles in situ from intact and insect damaged roots using SPME. The method is highly suitable for remote sampling and has potential for wide application in chemical ecology/root/soil research. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
|
438
|
Allafchian AR, Akhgar A, Ielbeigi V, Tabrizchi M. Determination of Xylene and Toluene by Solid-Phase Microextraction Using Au Nanoparticles-Thiol Silane Film Coupled to Ion Mobility Spectrometry. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2016; 97:670-676. [PMID: 27655079 DOI: 10.1007/s00128-016-1927-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2016] [Accepted: 09/15/2016] [Indexed: 06/06/2023]
Abstract
A simple, rapid and sensitive method for analysis of xylene and toluene was developed using the solid-phase microextraction (SPME) combined with ion mobilityspectrometry (IMS). Gold nanoparticles-thiol silane film (Au NPs-TSF) was applied as a newsorbent for SPME. Thiol silane film was formed on the surface of a stainless steel wire through incorporating Au nanoparticles during synthesis using sol-gel technique. The extraction properties of the fiber to xylene and toluene were examined, using a SPME device and thermal desorption ininjection port of IMS. The calibration graphs were linear in the range of 1.10-32.0 and 16.0-112.0 ppb for xylene and toluene, respectively. The detection limits for xylene and toluene were 0.7 and 8.0 ppb, respectively. The proposed method was applied without any considerable sample pretreatment and it was found to be simple enough to be strongly recommended for real sample analysis.
Collapse
|
439
|
Liu J, Wang B, Tai C, Wu L, Zhao H, Guan J, Chen L. An Effective Method to Detect Volatile Intermediates Generated in the Bioconversion of Coal to Methane by Gas Chromatography-Mass Spectrometry after In-Situ Extraction Using Headspace Solid-Phase Micro-Extraction under Strict Anaerobic Conditions. PLoS One 2016; 11:e0163949. [PMID: 27695055 PMCID: PMC5047463 DOI: 10.1371/journal.pone.0163949] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2016] [Accepted: 09/16/2016] [Indexed: 02/06/2023] Open
Abstract
Bioconversion of coal to methane has gained increased attention in recent decades because of its economic and environmental advantages. However, the mechanism of this process is difficult to study in depth, partly because of difficulties associated with the analysis of intermediates generated in coal bioconversion. In this investigation, we report on an effective method to analyze volatile intermediates generated in the bioconversion of coal under strict anaerobic conditions. We conduct in-situ extraction of intermediates using headspace solid-phase micro-extraction followed by detection by gas chromatography-mass spectrometry. Bioconversion simulation equipment was modified and combined with a solid-phase micro-extraction device. In-situ extraction could be achieved by using the combined units, to avoid a breakdown in anaerobic conditions and to maintain the experiment continuity. More than 30 intermediates were identified qualitatively in the conversion process, and the variation in trends of some typical intermediates has been discussed. Volatile organic acids (C2–C7) were chosen for a quantitative study of the intermediates because of their importance during coal bioconversion to methane. Fiber coating, extraction time, and solution acidity were optimized in the solid-phase micro-extraction procedure. The pressure was enhanced during the bioconversion process to investigate the influence of headspace pressure on analyte extraction. The detection limits of the method ranged from 0.0006 to 0.02 mmol/L for the volatile organic acids and the relative standard deviations were between 4.6% and 11.5%. The volatile organic acids (C2–C7) generated in the bioconversion process were 0.01–1.15 mmol/L with a recovery range from 80% to 105%. The developed method is useful for further in-depth research on the bioconversion of coal to methane.
Collapse
|
440
|
Yuan SF, Liu ZH, Lian HX, Yang C, Lin Q, Yin H, Dang Z. Simultaneous determination of estrogenic odorant alkylphenols, chlorophenols, and their derivatives in water using online headspace solid phase microextraction coupled with gas chromatography-mass spectrometry. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:19116-25. [PMID: 27344655 DOI: 10.1007/s11356-016-7107-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Accepted: 06/16/2016] [Indexed: 05/20/2023]
Abstract
A simple online headspace solid-phase microextraction (HS-SPME) coupled with the gas chromatography-mass spectrometry (GC-MS) method was developed for simultaneous determination of trace amounts of nine estrogenic odorant alkylphenols and chlorophenols and their derivatives in water samples. The extraction conditions of HS-SPME were optimized including fiber selection, extraction temperature, extraction time, and salt concentration. Results showed that divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber was the most appropriate one among the three selected commercial fibers, and the optimal extraction temperature, time, and salt concentration were 70 °C, 30 min, and 0.25 g/mL, respectively. The developed method was validated and showed good linearity (R (2) > 0.989), low limit of detection (LOD, 0.002-0.5 μg/L), and excellent recoveries (76-126 %) with low relative standard deviation (RSD, 0.7-12.9 %). The developed method was finally applied to two surface water samples and some of these target compounds were detected. All these detected compounds were below their odor thresholds, except for 2,4,6-TCAS and 2,4,6-TBAS wherein their concentrations were near their odor thresholds. However, in the two surface water samples, these detected compounds contributed to a certain amount of estrogenicity, which seemed to suggest that more attention should be paid to the issue of estrogenicity rather than to the odor problem.
Collapse
|
441
|
Haftka JJH, Scherpenisse P, Oetter G, Hodges G, Eadsforth CV, Kotthoff M, Hermens JLM. Critical micelle concentration values for different surfactants measured with solid-phase microextraction fibers. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2016; 35:2173-2181. [PMID: 26873883 DOI: 10.1002/etc.3397] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Revised: 01/15/2016] [Accepted: 02/10/2016] [Indexed: 06/05/2023]
Abstract
The amphiphilic nature of surfactants drives the formation of micelles at the critical micelle concentration (CMC). Solid-phase microextraction (SPME) fibers were used in the present study to measure CMC values of 12 nonionic, anionic, cationic, and zwitterionic surfactants. The SPME-derived CMC values were compared to values determined using a traditional surface tension method. At the CMC of a surfactant, a break in the relationship between the concentration in SPME fibers and the concentration in water is observed. The CMC values determined with SPME fibers deviated by less than a factor of 3 from values determined with a surface tension method for 7 out of 12 compounds. In addition, the fiber-water sorption isotherms gave information about the sorption mechanism to polyacrylate-coated SPME fibers. A limitation of the SPME method is that CMCs for very hydrophobic cationic surfactants cannot be determined when the cation exchange capacity of the SPME fibers is lower than the CMC value. The advantage of the SPME method over other methods is that CMC values of individual compounds in a mixture can be determined with this method. However, CMC values may be affected by the presence of compounds with other chain lengths in the mixture because of possible mixed micelle formation. Environ Toxicol Chem 2016;35:2173-2181. © 2016 SETAC.
Collapse
|
442
|
Cumeras R, Aksenov AA, Pasamontes A, Fung AG, Cianchetta AN, Doan H, Davis RM, Davis CE. Identification of fungal metabolites from inside Gallus gallus domesticus eggshells by non-invasively detecting volatile organic compounds (VOCs). Anal Bioanal Chem 2016; 408:6649-58. [PMID: 27457106 PMCID: PMC5014728 DOI: 10.1007/s00216-016-9778-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2016] [Revised: 06/11/2016] [Accepted: 07/07/2016] [Indexed: 11/30/2022]
Abstract
The natural porosity of eggshells allows hen eggs to become contaminated with microbes from the nesting material and environment. Those microorganisms can later proliferate due to the humid ambient conditions while stored in refrigerators, causing a potential health hazard to the consumer. The microbes' volatile organic compounds (mVOCs) are released by both fungi and bacteria. We studied mVOCs produced by aging eggs likely contaminated by fungi and fresh eggs using the non-invasive detection method of gas-phase sampling of volatiles followed by gas chromatography/mass spectrometry (GC/MS) analysis. Two different fungal species (Cladosporium macrocarpum and Botrytis cinerea) and two different bacteria species (Stenotrophomas rhizophila and Pseudomonas argentinensis) were identified inside the studied eggs. Two compounds believed to originate from the fungi themselves were identified. One fungus-specific compound was found in both egg and the fungi: trichloromethane. Graphical abstract Trichloromethane is a potential biomarker of fungal contamination of eggs.
Collapse
|
443
|
Antonucci A, Vitali M, Avino P, Manigrasso M, Protano C. Sensitive multiresidue method by HS-SPME/GC-MS for 10 volatile organic compounds in urine matrix: a new tool for biomonitoring studies on children. Anal Bioanal Chem 2016; 408:5789-5800. [PMID: 27311952 DOI: 10.1007/s00216-016-9682-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Revised: 05/24/2016] [Accepted: 06/01/2016] [Indexed: 11/25/2022]
Abstract
A HS-SPME method coupled with GC-MS analysis has been developed for simultaneously measuring the concentration of 10 volatile organic compounds (VOCs) (benzene, toluene, ethylbenzene, o-, m-, and p-xylene, methyl tert-butyl ether, ethyl tert-butyl ether, 2-methyl-2-butyl methyl ether, and diisopropyl ether) in urine matrix as a biomonitoring tool for populations at low levels of exposure to such VOCs. These compounds, potentially toxic for human health, are common contaminants of both outdoor and indoor air, as they are released by autovehicular traffic; some of them are also present in environmental tobacco smoke (ETS). Thus, the exposure to these pollutants cannot be neglected and should be assessed. The low limits of detection and quantification (LODs and LOQs <6.5 and 7.5 ng L(-1), respectively) and the high reproducibility (CVs <4 %) make the developed method suited for biomonitoring populations exposed at low levels such as children. Further, the method is cost-effective and low in time-consumption; therefore, it is useful for investigating large populations. It has been applied to children exposed to traffic pollution and/or ETS; the relevant results are reported, and the relevant implications are discussed.
Collapse
|
444
|
Williams JD, Yazarians JA, Almeyda CC, Anderson KA, Boyce GR. Detection of the Previously Unobserved Stereoisomers of Thujone in the Essential Oil and Consumable Products of Sage (Salvia officinalis L.) Using Headspace Solid-Phase Microextraction-Gas Chromatography-Mass Spectrometry. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2016; 64:4319-4326. [PMID: 27181395 DOI: 10.1021/acs.jafc.6b01065] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The discovery of the (+)-α-thujone and (-)-β-thujone stereoisomers in the essential oil of sage (Salvia officinalis L.) and dietary supplements is documented for the first time. The detection was accomplished using a chiral resolution protocol of racemic α-/β-thujone on headspace solid-phase microextraction-gas chromatography-mass spectrometry. Because the previously unreported stereoisomers, (+)-α-thujone and (-)-β-thujone, are not commercially available, a three-step synthesis of racemic thujone from commercially available starting materials was developed. Thermolysis studies demonstrated that no racemization at the cyclopropane stereocenters occurs, corroborating that the detection is not an artifact from the hydrodistillation process. The developed chiral resolution of thujone was also used to provide evidence for the absence of the (+)-α-thujone and (-)-β-thujone enantiomers in other common thujone-containing essential oils.
Collapse
|
445
|
Zhang M, Kruse NA, Bowman JR, Jackson GP. Field Analysis of Polychlorinated Biphenyls (PCBs) in Soil Using Solid-Phase Microextraction (SPME) and a Portable Gas Chromatography-Mass Spectrometry System. APPLIED SPECTROSCOPY 2016; 70:785-793. [PMID: 27170778 DOI: 10.1177/0003702816638268] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Accepted: 10/15/2015] [Indexed: 06/05/2023]
Abstract
An expedited field analysis method was developed for the determination of polychlorinated biphenyls (PCBs) in soil matrices using a portable gas chromatography-mass spectrometry (GC-MS) instrument. Soil samples of approximately 0.5 g were measured with a portable scale and PCBs were extracted by headspace solid-phase microextraction (SPME) with a 100 µm polydimethylsiloxane (PDMS) fiber. Two milliliters of 0.2 M potassium permanganate and 0.5 mL of 6 M sulfuric acid solution were added to the soil matrices to facilitate the extraction of PCBs. The extraction was performed for 30 min at 100 ℃ in a portable heating block that was powered by a portable generator. The portable GC-MS instrument took less than 6 min per analysis and ran off an internal battery and helium cylinder. Six commercial PCB mixtures, Aroclor 1016, 1221, 1232, 1242, 1248, 1254, and 1260, could be classified based on the GC chromatograms and mass spectra. The detection limit of this method for Aroclor 1260 in soil matrices is approximately 10 ppm, which is sufficient for guiding remediation efforts in contaminated sites. This method was applicable to the on-site analysis of PCBs with a total analysis time of 37 min per sample. However, the total analysis time could be improved to less than 7 min per sample by conducting the rate-limiting extraction step for different samples in parallel.
Collapse
|
446
|
Škulcová L, Neuwirthová N, Hofman J, Bielská L. Assessment of the biological and chemical availability of the freshly spiked and aged DDE in soil. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2016; 212:105-112. [PMID: 26840523 DOI: 10.1016/j.envpol.2016.01.042] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Revised: 01/15/2016] [Accepted: 01/15/2016] [Indexed: 06/05/2023]
Abstract
The study compared the ability of various chemical methods (XAD, β-hydroxypropylcyclodextrin - HPCD) and solid phase micro-extraction (SPME)) to mimic earthworm uptake from two similar soils containing either spiked or aged p,p´-DDE, thus representing two extreme scenarios with regard to the length of pollutant-soil contact time and the way of contamination. The extent of bioaccumulation was assessed at fixed exposure periods (10 and 21 days) and at equilibrium derived from uptake curves by multiple-point comparison or kinetic modeling. The decision on the best chemical predictor of biological uptake differed. The degree of bioaccumulation at equilibrium was best predicted by XAD while HPCD rather reflected the extent of accumulation derived after 21 days when, however, steady-state was not reached for spiked p,p´-DDE. SPME seemed to underestimate the uptake of aged p,p´-DDE, probably of the fraction taken up via soil particles. Thus, the degree of predictability seems to be associated with the capability of the chemical method to mimic the complex earthworm uptake via skin and intestinal tract as well as with the quality of biological data where the insufficient length of exposure period appears to be the major concern.
Collapse
|
447
|
Li JJ, Dong M, Liu YL, Zhang LL, Zhang Y, Yang ZY, Ren JN, Pan SY, Fan G. Effect of Food Emulsifiers on Aroma Release. Molecules 2016; 21:511. [PMID: 27110762 PMCID: PMC6272848 DOI: 10.3390/molecules21040511] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 04/09/2016] [Accepted: 04/14/2016] [Indexed: 11/16/2022] Open
Abstract
This study aimed to determine the influence of different emulsifiers or xanthan-emulsifier systems on the release of aroma compounds. Solid-phase microextraction (SPME) and GC-MS were used to study the effects of varying concentrations of xanthan gum, sucrose fatty acid ester, Tween 80 and soybean lecithin on the release of seven aroma compounds. The effects of the emulsifier systems supplemented with xanthan gum on aroma release were also studied in the same way. The results showed varying degrees of influence of sucrose fatty acid ester, soybean lecithin, Tween 80 and xanthan gum on the release of aroma compounds. Compared with other aroma compounds, ethyl acetate was more likely to be conserved in the solution system, while the amount of limonene released was the highest among these seven aroma compounds. In conclusion, different emulsifiers and complexes showed different surface properties that tend to interact with different aroma molecules. The present studies showed that the composition and structure of emulsifiers and specific interactions between emulsifiers and aroma molecules have significant effects on aroma release.
Collapse
|
448
|
Shi F, Liu J, Liang K, Liu R. Tris(pentafluoroethyl)trifluorophosphate-basd ionic liquids as advantageous solid-phase micro-extraction coatings for the extraction of organophosphate esters in environmental waters. J Chromatogr A 2016; 1447:9-16. [PMID: 27086567 DOI: 10.1016/j.chroma.2016.04.021] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 04/07/2016] [Accepted: 04/07/2016] [Indexed: 11/17/2022]
Abstract
Ionic liquids (ILs) containing the tris(pentafluoroethyl)trifluorophosphate [FAP] anion and various cations have great potential in sample preparation because of their excellent hydrophobicity, thermostability and low hydrolysity. In the present study, a [FAP]-based IL, 1-hexyl-3-methylimidazolium tris (pentafluoroethyl) trifluoro phosphate ([HMIM][FAP]), was used as coatings of solid-phase microextraction (SPME) for extracting organophosphate esters (OPEs) from environmental water samples. This SPME fiber was fabricated by coating a stainless steel wire substrate with [HMIM][FAP] via a simple direct dip-coating approach, and the extraction was conducted by the direct immersion solid phase microextraction. Coupling to gas chromatography mass spectrometry (GC-MS), the developed SPME method exhibited excellent selectivity and sensitivity towards the extraction of 11 OPEs from aqueous samples. Satisfactory linearity (R(2)≥0.99) of the calibration curves was obtained over the range of 0.05-50.0ngmL(-1) with the limits of detection (LODs, S/N=3) and limits of quantification (LOQs, S/N=10) ranged from 0.13-7.40ngL(-1) and 0.50-24.0ngL(-1), respectively. The proposed SPME method showed excellent extraction efficiency to OPEs with enrichment factors in the range of 168-2603, and acceptable reproducibility with relative standard deviations (RSDs) ≤15% for single fiber (n=7) and ≤16% for fiber-to-fiber (n=3×3) at a concentration level of 0.5ngmL(-1), respectively. The prepared IL-based fiber was successfully applied to determine eleven common used OPEs in tap water, influent and effluent of sewage treatment plant, with results are comparable to those determined by the reference (UPLC-MS/MS), and spiked recoveries in the range of 84.0-108%, 82.1-123% and 82.8-100%, respectively.
Collapse
|
449
|
Zhang S, Yang Q, Wang W, Wang C, Wang Z. Covalent Bonding of Metal-Organic Framework-5/Graphene Oxide Hybrid Composite to Stainless Steel Fiber for Solid-Phase Microextraction of Triazole Fungicides from Fruit and Vegetable Samples. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2016; 64:2792-801. [PMID: 26998567 DOI: 10.1021/acs.jafc.5b05831] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
A hybrid material of the zinc-based metal-organic framework-5 and graphene oxide (metal-organic framework-5/graphene oxide) was prepared as a novel fiber coating material for solid-phase microextraction (SPME). The SPME fibers were fabricated by covalent bonding via chemical cross-linking between the coating material metal-organic framework-5/graphene oxide and stainless steel wire. The prepared fiber was used for the extraction of five triazole fungicides from fruit and vegetable samples. Gas chromatography coupled with microelectron capture detector (GC-μECD) was used for quantification. The developed method gave a low limit of detection (0.05-1.58 ng g(-1)) and good linearity (0.17-100 ng g(-1)) for the determination of the triazole fungicides in fruit and vegetable samples. The relative standard deviations (RSDs) for five replicate extractions of the triazole fungicides ranged from 3.7 to 8.9%. The method recoveries for spiked fungicides (5, 20, and 50 ng g(-1)) in grape, apple, cucumber, celery cabbage, pear, cabbage, and tomato samples were in the range of 85.6-105.8% with the RSDs ranging from 3.6 to 11.4%, respectively, depending on both the analytes and samples. The metal-organic framework-5/graphene oxide coated fiber was stable enough for 120 extraction cycles without a significant loss of extraction efficiency. The method was suitable for the determination of triazole fungicides in fruit and vegetable samples.
Collapse
|
450
|
Niu Y, Hua L, Hardy G, Agarwal M, Ren Y. Analysis of volatiles from stored wheat and Rhyzopertha dominica (F.) with solid phase microextraction-gas chromatography mass spectrometry. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2016; 96:1697-1703. [PMID: 26018460 DOI: 10.1002/jsfa.7274] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 05/19/2015] [Accepted: 05/22/2015] [Indexed: 06/04/2023]
Abstract
BACKGROUND Volatile organic compounds (VOCs) contribute significantly to food flavour and can be used as indicators of quality, age of storage, and hygiene condition of stored products. The VOCs in the headspace of three different samples - healthy wheat, Rhyzopertha dominica, and wheat with R. dominica - were analysed at 25°C by solid phase micro-extraction (SPME) coupled with gas chromatography-flame ionisation detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). All the experimental conditions were kept consistent except a polar column and a non-polar column were used to assess the differences in volatile fingerprints. RESULTS A total of 114 volatiles were identified by both the polar and non-polar columns, of which 48 were specific to one of the three samples tested. The volatiles were mainly carbonyl chemical compounds such as aldehydes, ketones and alcohols. GC-MS results showed slightly more VOCs were identified from the polar column. The total number for the three samples was 43 from the polar column compared to 39 from the non-polar column. Conversely, 30 VOCs unique to a given sample were identified from the non-polar column compared to 18 from the polar column. CONCLUSION The use of both polar and non-polar columns is essential to capture the full range of VOCs produced by the three specific sample types investigated. The data can form the basis of enquiry into the relationship between storage and grain quality, and insect infestation and grain quality by observing the impact that these circumstances have on the production of volatile organic compounds.
Collapse
|