51
|
Abstract
Functional reconstruction of craniofacial defects is a major clinical challenge in craniofacial sciences. The advent of biomaterials is a potential alternative to standard autologous/allogenic grafting procedures to achieve clinically successful bone regeneration. This article discusses various classes of biomaterials currently used in craniofacial reconstruction. Also reviewed are clinical applications of biomaterials as delivery agents for sustained release of stem cells, genes, and growth factors. Recent promising advancements in 3D printing and bioprinting techniques that seem to be promising for future clinical treatments for craniofacial reconstruction are covered. Relevant topics in the bone regeneration literature exemplifying the potential of biomaterials to repair bone defects are highlighted.
Collapse
Affiliation(s)
- Greeshma Thrivikraman
- Division of Biomaterials and Biomechanics, Department of Restorative Dentistry, OHSU School of Dentistry, 2730 SW Moody Avenue, Portland, OR 97201, USA
| | - Avathamsa Athirasala
- Division of Biomaterials and Biomechanics, Department of Restorative Dentistry, OHSU School of Dentistry, 2730 SW Moody Avenue, Portland, OR 97201, USA
| | - Chelsea Twohig
- Division of Biomaterials and Biomechanics, Department of Restorative Dentistry, OHSU School of Dentistry, 2730 SW Moody Avenue, Portland, OR 97201, USA
| | - Sunil Kumar Boda
- Mary and Dick Holland Regenerative Medicine Program, Department of Surgery-Transplant, University of Nebraska Medical Center, Omaha, NE 68198-5965, USA
| | - Luiz E Bertassoni
- Division of Biomaterials and Biomechanics, Department of Restorative Dentistry, OHSU School of Dentistry, 2730 SW Moody Avenue, Portland, OR 97201, USA; Department of Biomedical Engineering, OHSU School of Medicine, 3303 SW Bond Avenue, Portland, OR 97239, USA; OHSU Center for Regenerative Medicine, 3181 SW Sam Jackson Park Road, Portland, OR 97239, USA.
| |
Collapse
|
52
|
Shankar T, Garhnayak M, Garhnayak L, Dhal A, Kar AK. Comparison of Hypersensitivity in Metal Ceramic Crowns cemented with Zinc Phosphate and Self-adhesive Resin: A Prospective Study. J Contemp Dent Pract 2017; 18:923-926. [PMID: 28989131 DOI: 10.5005/jp-journals-10024-2150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
BACKGROUND Luting agents used to fix artificial prostheses, such as fixed partial denture (FPD) to tooth are basically viscous in nature and show chemical reaction for fixation. Postcementation hypersensitivity is a frequent complaint of patients. The present study was conducted to compare postcementation hypersensitivity with zinc phosphate and self-adhesive resin in complete coverage crown. MATERIALS AND METHODS This study included 30 patients in which 60 porcelein fused to metal crowns was placed. Two metal crowns were placed in each patient in nonantagonis-tic contralateral quadrants. First crown was cemented with zinc phosphate cement, while the other was cemented with self-adhesive resin. Hypersensitivity was evaluated by visual analog scale (VAS) score and by clinical test. For clinical evaluation of sensitivity, hot and cold water was applied to the cervical margin of restoration for 5 seconds and response was recorded. RESULTS This study consisted of 30 patients in which 60 crowns were given. There was no statistical difference in VAS score of mastication in zinc phosphate cement recorded at baseline, 1 week, 4 weeks, 6 months, 1 year, and 2 years (p > 0.05). Cold response also did not show a significant difference at six time points. Warm response showed slight decrease in subsequent time points but was nonsignificant (p > 0.05). Similarly, with self-adhesive resin cement, VAS score during mastication, hot and cold response was statistically nonsignificant (p > 0.05). CONCLUSION Postcementation hypersensitivity is a frequent complaint that patient may experience. However, we found no statistically significant difference in both cements tested. CLINICAL SIGNIFICANCE Postcementation hypersensitivity is an unpleasant sensation experienced by patients. This may affect the success of any prosthesis. Thus, selection of luting agent for cementation plays an important role to eliminate this symptom.
Collapse
Affiliation(s)
- Thatapudi Shankar
- Department of Prosthodontics, Kalinga Institute of Dental Sciences, KIIT University, Bhubaneswar, Odisha, India, Phone: +919441333906 e-mail:
| | - Mirna Garhnayak
- Department of Prosthodontics, Institute of Dental Sciences Siksha 'O' Anushandhan University, Bhubaneswar, Odisha, India
| | - Lokanath Garhnayak
- Department of Prosthodontics, Sriram Chandra Bhanj Dental College & Hospital, Cuttack, Odisha, India
| | - Angurbala Dhal
- Department of Prosthodontics, Sriram Chandra Bhanj Dental College & Hospital, Cuttack, Odisha, India
| | - Aswini K Kar
- Department of Prosthodontics, Kalinga Institute of Dental Sciences, KIIT University, Bhubaneswar, Odisha, India
| |
Collapse
|
53
|
Abstract
A survey of the development of dental ceramics is presented to provide a better understanding of the rationale behind the development and clinical indications of each class of ceramic material. Knowledge of the composition, microstructure, and properties of a material is critical for selecting the right material for specific applications. The key to successful ceramic restorations rests on material selection, manufacturing technique, and restoration design, including the balancing of several factors such as residual stresses, tooth contact conditions, tooth size and shape, elastic modulus of the adhesives and tooth structure, and surface state.
Collapse
Affiliation(s)
- Yu Zhang
- Department of Biomaterials and Biomimetics, NYU College of Dentistry, 433 First Avenue, Room 810, New York, NY 10010, USA.
| | - J Robert Kelly
- Department of Biomedical Engineering, University of Connecticut Health Center, Mailstop 1615, 263 Farmington Avenue, Farmington, CT 06030-1615, USA
| |
Collapse
|
54
|
Puppin-Rontani J, Sundfeld D, Costa AR, Correr AB, Puppin-Rontani RM, Borges GA, Sinhoreti M, Correr-Sobrinho L. Effect of Hydrofluoric Acid Concentration and Etching Time on Bond Strength to Lithium Disilicate Glass Ceramic. Oper Dent 2017; 42:606-615. [PMID: 28708007 DOI: 10.2341/16-215-l] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this study was to evaluate the influence of different concentrations of hydrofluoric acid (HF) associated with varied etching times on the microshear bond strength (μSBS) of a resin cement to a lithium disilicate glass ceramic. Two hundred seventy-five ceramic blocks (IPS e.max Press [EMX], Ivoclar Vivadent), measuring 8 mm × 3 mm thickness, were randomly distributed into five groups according to the HF concentrations (n=50): 1%, 2.5%, 5%, 7.5%, and 10%. Further random distribution into subgroups was performed according to the following etching times (n=10): 20, 40, 60, 120, and 20 + 20 seconds. After etching, all blocks were treated with a silane coupling agent followed by a thin layer of an unfilled resin. Three resin cement cylinders (∅=1 mm) were made on each EMX surface, which was then stored in deionized water at 37°C for 24 hours before testing. The μSBS was in a universal testing machine at a crosshead speed of 1 mm/min until failure. Data were submitted to two-way analysis of variance, and multiple comparisons were performed using the Tukey post hoc test (α=0.05). One representative EMX sample was etched according to the description of each subgroup and evaluated using scanning electron microscopy for surface characterization. The HF concentrations of 5%, 7.5%, and 10% provided significantly higher μSBS values than 1% and 2.5% (p<0.05), regardless of the etching times. For 1% and 2.5% HF, the etching times from 40 to 120 seconds increased the μSBS values compared with 20 seconds (p<0.05), but etching periods did not differ within the 5%, 7.5%, and 10% HF groups (p>0.05). The effect of re-etching was more evident for 1% and 2.5% HF (p<0.05). Different HF concentrations/etching times directly influenced the bond strength and surface morphology of EMX.
Collapse
|
55
|
Moro AFV, Ramos AB, Rocha GM, Perez CDR. Effect of prior silane application on the bond strength of a universal adhesive to a lithium disilicate ceramic. J Prosthet Dent 2017; 118:666-671. [PMID: 28385437 DOI: 10.1016/j.prosdent.2016.12.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 12/01/2016] [Accepted: 12/01/2016] [Indexed: 11/18/2022]
Abstract
STATEMENT OF PROBLEM Universal adhesives combine silane and various monomers in a single bottle to make them more versatile. Their adhesive performance is unclear. PURPOSE The purpose of this in vitro study was to assess the effects of an additional silane application before using a universal adhesive on the adhesion between a disilicate glass ceramic and a composite resin by using a microshear bond strength test (μSBS) and fracture analysis immediately and after thermocycling. MATERIAL AND METHODS One hundred lithium disilicate glass ceramic disks were divided into 10 groups for bond strength testing according to the following 3 surface treatments: silane application (built-in universal adhesive or with additional application), adhesive (Adper Single Bond Plus [SB, 3M ESPE], Scotchbond Universal Adhesive [U, 3M ESPE], and mixed U with Dual Cure Activator [DCA, 3M ESPE]); or thermocycling (half of the specimens were thermocycled 10000 times). After surface treatment, 5 resin cylinders were bonded to each disk and submitted to a μSBS test. The failure mode was analyzed under a stereomicroscope and evaluated by scanning electron microscope and energy-dispersive x-ray spectroscopy. Data from the μSBS test were analyzed by 3-way ANOVA followed by the Tukey HSD post hoc test (α=.05). RESULTS An additional silane application resulted in a higher μSBS result for all adhesive groups (P<.05). CONCLUSIONS Ceramic surface treatment influenced the performance of adhesives, which may be improved with an additional silane application.
Collapse
Affiliation(s)
| | - Amanda Barreto Ramos
- Doctoral student, Department of Clinical Procedures, Rio de Janeiro State University, Rio de Janeiro, Brazil
| | - Gustavo Miranda Rocha
- Postdoctoral student, Institute of Biophysics Carlos Chagas Filho, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Cesar Dos Reis Perez
- Associate Professor, Department of Prosthesis, Rio de Janeiro State University, Rio de Janeiro, Brazil
| |
Collapse
|
56
|
Perroni AP, Bergoli CD, Dos Santos MBF, Moraes RR, Boscato N. Spectrophotometric analysis of clinical factors related to the color of ceramic restorations: A pilot study. J Prosthet Dent 2017; 118:611-616. [PMID: 28385444 DOI: 10.1016/j.prosdent.2016.12.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 12/30/2016] [Accepted: 12/30/2016] [Indexed: 11/18/2022]
Abstract
STATEMENT OF PROBLEM Shade matching natural teeth with ceramic restorations is still an esthetic, clinical challenge. PURPOSE The purpose of this prospective clinical study was to evaluate the influence of color-related factors on the color variation of ceramic restorations based on spectrophotometric analysis. MATERIAL AND METHODS Color records were obtained from 11 participants who received 38 lithium disilicate restorations. CIELab color coordinates were measured with a spectrophotometer on the ceramic restoration, tooth (baseline), prepared tooth, and luted ceramics. Color variation (ΔE00) was calculated for each variable (luting agent and restoration type, tooth substrate shade, ceramic thickness, and translucency parameters) measured at baseline on the prepared tooth and after cementation of the restorations. Confidence intervals (CI) for the means (95% CI) were calculated, and the ΔE00 values and CIELab individual color coordinates were compared for each pair of variable by using the Student t test or Welch test (α=.05). RESULTS Greater color variation values were observed between measurements obtained on the prepared tooth and luted restoration. The lower ΔE00 values were observed over darker tooth substrate measured at baseline and after luting (P=.007). CONCLUSIONS The 3 conditions evaluated presented clinically visible color differences, highlighting the importance of clinical evaluations on the visual color acceptability limits for restorations, which are usually defined in laboratory studies. The lithium disilicate ceramic showed lower masking ability over darker tooth substrate, whereas the coordinates L*, a*, and b* were cementation-dependent.
Collapse
Affiliation(s)
- Ana Paula Perroni
- Doctoral student, Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil
| | - César D Bergoli
- Professor, Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil
| | | | - Rafael R Moraes
- Professor, Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil
| | - Noéli Boscato
- Professor, Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Brazil.
| |
Collapse
|
57
|
Varnum C. Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome. Dan Med J 2017; 64:B5350. [PMID: 28260601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Total hip arthroplasty (THA) is a common and successful treatment of patients suffering from severe osteoarthritis that significantly reduces pain and improves hip function and quality of life. Traditionally, the outcome of THA has been evaluated by orthopaedic surgeons and assessed in morbidity and mortality rates, and implant survival. As patients and surgeons may assess outcome after THA differently, patient-reported outcomes (PROMs) have gained much more interest and are today recognized as very important tools for evaluating the outcome and satisfaction after THA. One of the prognostic factors for the outcome of THA is the type of bearings. This PhD thesis focuses on the influence of different types of bearings on implant survival, revision causes, PROMs, and noises from THA. The aims of the thesis were: Study I: To examine the revision risk and to investigate the causes of revision of cementless ceramic-on-ceramic (CoC) THAs comparing them to those of "standard" metal-on-polyethylene (MoP) THAs. Study II: To compare the six-year revision risk for metal-on-metal (MoM) with that for MoP bearings in cementless stemmed THA, and further to study the revision risk for different designs of stemmed MoM THAs and the causes of revision. Study III: To examine the association between CoC, MoM, and MoP bearings and both generic and disease-specific PROMs, and furthermore to examine the incidence and types of noises from the three types of bearings and identify the effect of noises on PROM scores. In study I and III, we used data from the Danish Hip Arthroplasty Registry combined with data from the Civil Registration System and the Danish National Patient Registry. In study II, data from the Nordic Arthroplasty Register Association, containing data from hip arthroplasty registries in Denmark, Norway, Sweden, and Finland, was used. In study I, 11,096 patients operated from 2002 through 2009 with cementless THA were included. Of these, 16% had CoC THA and 84% had MoP THA. At 8.7-year follow-up, no difference in RR of revision for any cause was found for CoC compared to MoP THA. One cause of revision related only to CoC THA is ceramic fracture. Medical records were reviewed for patients who had revision surgery due to component failure, and six patients (0,34%) had been revised due to ceramic fracture. No other difference in prevalence of causes of revision was found when comparing CoC to MoP THA. Study II included 32,678 patients who were operated from 2002 through 2010 with cementless stemmed THA with either MoM bearings (11,567 patients, 35%) or MoP bearings (21,111 patients, 65%). At six-year follow-up, the RR of revision for any cause was significantly higher for MoM compared to MoP THA. When comparing different combinations of cup/stem with MoM to MoP bearings, there was an increased RR of revision for any cause for the ASR/Summit, ASR/Corail, and "other" combinations. There was a higher prevalence of revision due to aseptic loosening for MoM compared to MoP THA. In contrast, the prevalence of revision due to dislocation was lower for MoM THA. In study III, a set of questionnaires including HOOS, EQ-5D, UCLA activity score, and a questionnaire about noises from the THA was sendt to patients having THA with CoC, MoM, or MoP bearings. The response rate was 85% and among the 3,089 patients responding, 45% received CoC, 17% MoM, and 38% MoP THA. No differences in mean subscale scores were found for CoC and MoM compared to MoP THA, except for CoC THA that had a lower mean HOOS symptoms score than MoP THA. 27% of patients with CoC, 29% of patients with MoM, and 12% of patients with MoP bearings had experienced noises from the THA. For the three types of bearings, PROM scores from patients with noisy THA were significantly lower when compared to silent MoP THA, except for noisy CoC and MoM THA that had the same mean UCLA activity score as silent MoP THA.
Collapse
|
58
|
Pugely AJ, Petersen EB, DeVries-Watson N, Fredericks DC. Influence of 45S5 Bioactive Glass in A Standard Calcium Phosphate Collagen Bone Graft Substitute on the Posterolateral Fusion of Rabbit Spine. Iowa Orthop J 2017; 37:193-198. [PMID: 28852357 PMCID: PMC5508293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
INTRODUCTION Spinal fusion surgery is an effective but costly treatment for select spinal pathology. Historically iliac crest bone graft (ICBG) has remained the gold standard for achieving successful arthrodesis. Given well-established morbidity autograft harvest, multiple bone graft replacements, void fillers, and extenders have been developed. The objective of this study was to evaluate the in vivo efficacy and safety of two mineralized collagen bone void filler materials similar in composition. Both bone void fillers were composed of hydroxyapatite (HA), tricalcium phosphate (TCP) and bovine collagen. The first test article (Bi-Ostetic bioactive glass foam or "45S5") also contained 45S5 bioactive glass particles while the second test article (Formagraft or "FG") did not. 45S5 and FG were combined with bone marrow aspirate and iliac crest autograft and compared to ICBG in an established posterolateral spine fusion rabbit model. MATERIALS AND METHODS Sixty-nine mature New Zealand White rabbits were divided into 3 test cohorts: ICBG, 45S5, and FG. A Posterolateral fusion model previous validated was utilized to assess fusion efficacy. The test groups were evaluated for spine fusion rate, new bone formation, graft resorption and inflammatory response using radiographic, μCT, biomechanical and histological endpoints at 4, 8 and 12 weeks following implantation. RESULTS There were 4 clinical complications unrelated to the graft materials and were evenly split between groups (ICBG graft harvest complications; hind limb mobility, chronic pain) and were euthanized. These omissions did not affect the overall outcome of the study. Radiographic scoring of the fusion sites indicated a normal healing response in all test groups, with no adverse reactions and similar progressions of new bone formation observed over time. All groups demonstrated significantly less range of motion in both flexion/extension and lateral bending compared to normal not-fused controls, which supports fusion results observed in the other endpoints. Fusion occurred earlier in the 45S5 group: ICBG 0%, FG 0%, and 45S5 20% at 4 weeks; ICBG 43%, FG 38%, and 45S5 50% at 8 weeks; and ICBG 50%, FG 56%, and 45S5 56% at 12 weeks. Histopathology analysis of the fusion masses, from each test article and time point, indicated an expected normal response for resorbable calcium phosphate (HA/TCP) and collagen graft material. Mild inflammation with macrophage and multinucleated giant cell response to the graft material was evident in all test groups. DISCUSSION This study has confirmed the biocompatibility, safety, efficacy and bone healing characteristics of the HA-TCP collagen (with or without 45S5 bioactive glass) composites. The results show that the 3 test groups had equivalent long-term fusion performance and outcome at 12 weeks. However, the presence of 45S5 bioactive glass seemed to accelerate the fusion process as evidenced by the higher fusion rates at 4 and 8 weeks for the HA-TCP-collagen composite containing bioactive glass particles. The results also demonstrate that the HA-TCP-45S5 bioactive glass-collagen composite used as an extender closely mirrors the healing characteristics (i.e. amount and quality of bone) of the 100% autograft group.
Collapse
Affiliation(s)
- Andrew J Pugely
- University of Iowa Department of Orthopaedics200 Hawkins Drive, 01029 JPP Iowa City, Iowa 52242
| | - Emily B Petersen
- University of Iowa Department of Orthopaedics200 Hawkins Drive, 01029 JPP Iowa City, Iowa 52242
| | | | - Douglas C Fredericks
- University of Iowa Department of Orthopaedics200 Hawkins Drive, 01029 JPP Iowa City, Iowa 52242
| |
Collapse
|
59
|
Church TD, Jessup JP, Guillory VL, Vandewalle KS. Translucency and strength of high-translucency monolithic zirconium oxide materials. Gen Dent 2017; 65:48-52. [PMID: 28068266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The purpose of this study was to evaluate the translucency and strength of highly translucent monolithic zirconia ceramic materials recently introduced to the market. Four monolithic zirconium oxide materials promoted as having high translucency (BruxZir Shaded 16, BruxZir HT, Lava Plus, and inCoris TZI C) were compared to a high-translucency, lithium disilicate monolithic glass-ceramic material (IPS e.max CAD HT). To evaluate translucency, the materials were sectioned into 0.5-, 1.0-, 1.5-, and 2.0-mm-thick specimens; all were sintered and polished. Translucency parameters were calculated with a spectrophotometer. To evaluate flexural strength and modulus, the ceramic materials were sectioned to create beams and fractured in a universal testing machine. The lithium disilicate had significantly greater translucency than the zirconia materials at each thickness. In general, the translucencies of the zirconia materials were similar at each thickness. However, at the manufacturers' recommended minimal thicknesses, 0.5-mm specimens of BruxZir Shaded 16, inCoris TZI C, and Lava Plus were more translucent than the 1.0-mm-thick specimens of IPS e.max CAD HT. Translucency significantly decreased for each material at each increase in thickness. The flexural strengths of the zirconia materials were similar to each other and significantly greater than that of IPS e.max CAD HT. Flexural moduli were more variable. Of the zirconia materials, BruxZir Shaded 16 had an overall better combination of translucency, strength, and modulus.
Collapse
|
60
|
Horvath SD. Key Parameters of Hybrid Materials for CAD/CAM-Based Restorative Dentistry. Compend Contin Educ Dent 2016; 37:638-643. [PMID: 27700130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Hybrid materials are a recent addition to the dental armamentarium for computer-assisted design/ computer-assisted manufacturing (CAD/CAM)-based restorative dentistry. They are intended to provide dentists with the capability of restoring single teeth in one appointment with a material that emulates the structure and physical properties of natural teeth. This article aims to provide an overview of currently available hybrid materials and offer the reader further understanding of their key clinical parameters and possible limitations.
Collapse
Affiliation(s)
- Sebastian D Horvath
- Department of Preventive and Restorative Sciences, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Prosthodontics, School of Dentistry, Albert-Ludwigs University Freiburg, Germany; Private Practice, Jestetten, Germany
| |
Collapse
|
61
|
Blatz MB, Alvarez M, Sawyer K, Brindis M. How to Bond Zirconia: The APC Concept. Compend Contin Educ Dent 2016; 37:611-618. [PMID: 27700128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Zirconia has become one of the most popular materials in dentistry. New high-translucent zirconia ceramics have favorable optical properties and can be applied as monolithic full-contour restorations in various clinical indications for posterior and anterior teeth. However, having reliable cementation protocols is fundamental for clinical success of indirect ceramic dental restorations, including those made from zirconia materials. Resin bonding supports ceramic restorations and is necessary for onlays, laminate veneers, and resinbonded fixed dental prostheses. The APC zirconia-bonding concept is based on decades of research on how to achieve high and long-term durable bond strengths to high-strength ceramics. It includes three practical steps: (A) airparticle abrasion, (P) zirconia primer, and (C) adhesive composite resin. This article discusses the history and development of high-translucent zirconia and explains the necessity for proper cementation. The rationale and science behind a simplified zirconia-bonding concept is explained and illustrated with a clinical case presentation.
Collapse
Affiliation(s)
- Markus B Blatz
- Professor of Restorative Dentistry, Chair, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - Kimiyo Sawyer
- President, Cusp Dental Laboratory, Malden, Massachusetts
| | - Marco Brindis
- Assistant Professor of Clinical Prosthodontics and Interim Chair, Department of Prosthodontics, Louisiana State University School of Dentistry, New Orleans, Louisiana
| |
Collapse
|
62
|
Spitznagel FA, Vuck A, Gierthmühlen PC, Blatz MB, Horvath SD. Adhesive Bonding to Hybrid Materials: An Overview of Materials and Recommendations. Compend Contin Educ Dent 2016; 37:630-637. [PMID: 27700131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Recently, hybrid materials have been introduced to the dental market. Together with computer-assisted design/computer-assisted manufacturing (CAD/CAM) composite resins, they form a new class of dental CAD/CAM materials that combine the positive effects of ceramics and composites. As bonding is essential for their clinical longevity, it is crucial to have a good understanding of their material properties and cementation protocols. This review offers clinicians an overview of available hybrid materials and recommendations for their respective adhesive placements.
Collapse
Affiliation(s)
- Frank A Spitznagel
- Assistant Professor, Department of Prosthodontics, School of Dentistry, Heinrich - Heine - University, Düsseldorf, Germany
| | - Alexander Vuck
- Associate Professor, Department of Prosthodontics, School of Dentistry, Heinrich - Heine - University, Düsseldorf, Germany
| | - Petra C Gierthmühlen
- Professor and Chair, Department of Prosthodontics, School of Dentistry, Heinrich - Heine - University, Düsseldorf, Germany
| | - Markus B Blatz
- Department of Preventive and Restorative Sciences, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Prosthodontics, School of Dentistry, Albert-Ludwigs University, Freiburg, Germany
| | - Sebastian D Horvath
- Department of Preventive and Restorative Sciences, University of Pennsylvania, Philadelphia, PA; Department of Prosthodontics, School of Dentistry, Albert-Ludwigs University Freiburg, Germany; Private Practice, Jestetten, Germany
| |
Collapse
|
63
|
Floroian L, Ristoscu C, Mihailescu N, Negut I, Badea M, Ursutiu D, Chifiriuc MC, Urzica I, Dyia HM, Bleotu C, Mihailescu IN. Functionalized Antimicrobial Composite Thin Films Printing for Stainless Steel Implant Coatings. Molecules 2016; 21:molecules21060740. [PMID: 27294895 PMCID: PMC6274373 DOI: 10.3390/molecules21060740] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Revised: 06/01/2016] [Accepted: 06/02/2016] [Indexed: 01/24/2023] Open
Abstract
In this work we try to address the large interest existing nowadays in the better understanding of the interaction between microbial biofilms and metallic implants. Our aimed was to identify a new preventive strategy to control drug release, biofilm formation and contamination of medical devices with microbes. The transfer and printing of novel bioactive glass-polymer-antibiotic composites by Matrix-Assisted Pulsed Laser Evaporation into uniform thin films onto 316 L stainless steel substrates of the type used in implants are reported. The targets were prepared by freezing in liquid nitrogen mixtures containing polymer and antibiotic reinforced with bioglass powder. The cryogenic targets were submitted to multipulse evaporation by irradiation with an UV KrF* (λ = 248 nm, τFWHM ≤ 25 ns) excimer laser source. The prepared structures were analyzed by infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy and profilometry, before and after immersion in physiological fluids. The bioactivity and the release of the antibiotic have been evaluated. We showed that the incorporated antibiotic underwent a gradually dissolution in physiological fluids thus supporting a high local treatment efficiency. Electrochemical measurements including linear sweep voltammetry and impedance spectroscopy studies were carried out to investigate the corrosion resistance of the coatings in physiological environments. The in vitro biocompatibility assay using the MG63 mammalian cell line revealed that the obtained nanostructured composite films are non-cytotoxic. The antimicrobial effect of the coatings was tested against Staphylococcus aureus and Escherichia coli strains, usually present in implant-associated infections. An anti-biofilm activity was evidenced, stronger against E. coli than the S. aureus strain. The results proved that the applied method allows for the fabrication of implantable biomaterials which shield metal ion release and possess increased biocompatibility and resistance to microbial colonization and biofilm growth.
Collapse
Affiliation(s)
- Laura Floroian
- Faculty of Electrical Engineering and Computer Science, 1 Politehnicii Str., Transilvania University of Brasov, Brasov 500024, Romania.
| | - Carmen Ristoscu
- National Institute for Laser, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, Ilfov RO-77125, Romania.
| | - Natalia Mihailescu
- National Institute for Laser, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, Ilfov RO-77125, Romania.
| | - Irina Negut
- National Institute for Laser, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, Ilfov RO-77125, Romania.
- Faculty of Physics, University of Bucharest, Magurele, Ilfov 077125, Romania.
| | - Mihaela Badea
- Faculty of Medicine, 56 N. Balcescu Str., Transilvania University of Brasov, Brasov 500019, Romania.
| | - Doru Ursutiu
- Faculty of Electrical Engineering and Computer Science, 1 Politehnicii Str., Transilvania University of Brasov, Brasov 500024, Romania.
| | - Mariana Carmen Chifiriuc
- Faculty of Biology, Research Institute of the University of Bucharest-ICUB, University of Bucharest, Spl. Independentei 91-95, Bucharest 050095, Romania.
| | - Iuliana Urzica
- National Institute for Laser, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, Ilfov RO-77125, Romania.
| | - Hussien Mohammed Dyia
- Faculty of Biology, Research Institute of the University of Bucharest-ICUB, University of Bucharest, Spl. Independentei 91-95, Bucharest 050095, Romania.
| | - Coralia Bleotu
- "Stefan S. Nicolau" Institute of Virology, 285 Mihai Bravu Avenue, Bucharest 30304, Romania.
| | - Ion N Mihailescu
- National Institute for Laser, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, Ilfov RO-77125, Romania.
| |
Collapse
|
64
|
Mohapatra S, Patro S, Mishra S. Bioactive Materials in Endodontics: An Evolving Component of Clinical Dentistry. Compend Contin Educ Dent 2016; 38:376-382. [PMID: 28570083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Achieving biocompatibility in a material requires an interdisciplinary approach that involves a sound knowledge of materials science, bioengineering, and biotechnology. The host microbial-material response is also critical. Endodontic treatment is a delicate procedure that must be planned and executed properly. Despite major advances in endodontic therapy in recent decades, clinicians are confronted with a complex root canal anatomy and a wide selection of endodontic filling materials that, in turn, may not be well tolerated by the periapical tissues and may evoke an immune reaction. This article discusses published reports of various bioactive materials that are used in endodontic therapy, including calcium hydroxide, mineral trioxide aggregate, a bioactive dentin substrate, calcium phosphate ceramics, and calcium phosphate cements.
Collapse
Affiliation(s)
- Satyajit Mohapatra
- Post Graduate, Department of Endodontics, Institute of Dental Sciences, Bhubaneswar, India
| | - Swadheena Patro
- Reader, Department of Endodontics, Institute of Dental Sciences, Bhubaneswar, India
| | - Sumita Mishra
- Senior Lecturer, Department of Orthodontics, Institute of Dental Sciences, Bhubaneswar, India
| |
Collapse
|
65
|
Alfaro MJ, Meyers EJ, Ashcraft-Olmscheid D, Vandewalle KS. Effect of a new salivary-contaminant removal method on bond strength. Gen Dent 2016; 64:51-54. [PMID: 27148657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The study evaluated the effect of salivary-contaminant removal methods on the bond strength of resin cement to hydrofluoric acid-etched ceramic. Treatment with a new cleaning paste resulted in bond strengths not significantly different from those obtained in phosphoric acid-treated, hydrofluoric acid-treated, and uncontaminated control groups; thus the paste may be considered an alternative to phosphoric acid or hydrofluoric acid for removal of salivary contaminants.
Collapse
|
66
|
Tsirogiannis P, Reissmann DR, Heydecke G. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: A systematic review and meta-analysis. J Prosthet Dent 2016; 116:328-335.e2. [PMID: 27061627 DOI: 10.1016/j.prosdent.2016.01.028] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Revised: 01/27/2016] [Accepted: 01/28/2016] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM In existing published reports, some studies indicate the superiority of digital impression systems in terms of the marginal accuracy of ceramic restorations, whereas others show that the conventional method provides restorations with better marginal fit than fully digital fabrication. Which impression method provides the lowest mean values for marginal adaptation is inconclusive. The findings from those studies cannot be easily generalized, and in vivo studies that could provide valid and meaningful information are limited in the existing publications. PURPOSE The purpose of this study was to systematically review existing reports and evaluate the marginal fit of ceramic single-tooth restorations after either digital or conventional impression methods by combining the available evidence in a meta-analysis. MATERIAL AND METHODS The search strategy for this systematic review of the publications was based on a Population, Intervention, Comparison, and Outcome (PICO) framework. For the statistical analysis, the mean marginal fit values of each study were extracted and categorized according to the impression method to calculate the mean value, together with the 95% confidence intervals (CI) of each category, and to evaluate the impact of each impression method on the marginal adaptation by comparing digital and conventional techniques separately for in vitro and in vivo studies. RESULTS Twelve studies were included in the meta-analysis from the 63 identified records after database searching. For the in vitro studies, where ceramic restorations were fabricated after conventional impressions, the mean value of the marginal fit was 58.9 μm (95% CI: 41.1-76.7 μm), whereas after digital impressions, it was 63.3 μm (95% CI: 50.5-76.0 μm). In the in vivo studies, the mean marginal discrepancy of the restorations after digital impressions was 56.1 μm (95% CI: 46.3-65.8 μm), whereas after conventional impressions, it was 79.2 μm (95% CI: 59.6-98.9 μm) CONCLUSION No significant difference was observed regarding the marginal discrepancy of single-unit ceramic restorations fabricated after digital or conventional impressions.
Collapse
Affiliation(s)
- Panagiotis Tsirogiannis
- Postgraduate student, Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Daniel R Reissmann
- Associate Professor, Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Guido Heydecke
- Professor, Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
67
|
Shuai C, Zhou J, Gao D, Gao C, Feng P, Peng S. Functionalization of Calcium Sulfate/Bioglass Scaffolds with Zinc Oxide Whisker. Molecules 2016; 21:378. [PMID: 26999100 PMCID: PMC6273971 DOI: 10.3390/molecules21030378] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2016] [Revised: 03/04/2016] [Accepted: 03/14/2016] [Indexed: 11/29/2022] Open
Abstract
There are urgent demands for satisfactory antibacterial activity and mechanical properties of bone scaffolds. In this study, zinc oxide whisker (ZnOw) was introduced into calcium sulfate/bioglass scaffolds. Antimicrobial behavior was analyzed using Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus). The results showed that the scaffolds presented a strong antibacterial activity after introducing ZnOw, due to the antibacterial factors released from the degradation of ZnO. Moreover, ZnOw was also found to have a distinct reinforcing effect on mechanical properties. This was ascribed to whisker pull-out, crack bridging, crack deflection, crack branching and other toughening mechanisms. In addition, the cell culture experiments showed that the scaffolds with ZnOw had a good biocompatibility.
Collapse
Affiliation(s)
- Cijun Shuai
- State Key Laboratory of High Performance Complex Manufacturing, Central South University, Changsha 410083, China.
- Shenzhen Research Institute, Central South University, Shenzhen 518057, China.
| | - Jianhua Zhou
- State Key Laboratory of High Performance Complex Manufacturing, Central South University, Changsha 410083, China.
| | - Dan Gao
- School of Basic Medical Science, Central South University, Changsha 410078, China.
| | - Chengde Gao
- State Key Laboratory of High Performance Complex Manufacturing, Central South University, Changsha 410083, China.
| | - Pei Feng
- State Key Laboratory of High Performance Complex Manufacturing, Central South University, Changsha 410083, China.
| | - Shuping Peng
- School of Basic Medical Science, Central South University, Changsha 410078, China.
| |
Collapse
|
68
|
Vivan RR, Mecca CE, Biguetti CC, Rennó ACM, Okamoto R, Cavenago BC, Duarte MH, Matsumoto MA. Experimental maxillary sinus augmentation using a highly bioactive glass ceramic. J Mater Sci Mater Med 2016; 27:41. [PMID: 26712707 DOI: 10.1007/s10856-015-5652-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2015] [Accepted: 12/16/2015] [Indexed: 06/05/2023]
Abstract
Physicochemical characteristics of a biomaterial directly influence its biological behavior and fate. However, anatomical and physiological particularities of the recipient site also seem to contribute with this process. The present study aimed to evaluate bone healing of maxillary sinus augmentation using a novel bioactive glass ceramic in comparison with a bovine hydroxyapatite. Bilateral sinus augmentation was performed in adult male rabbits, divided into 4 groups according to the biomaterial used: BO-particulate bovine HA Bio-Oss(®) (BO), BO+G-particulate bovine HA + particulate autogenous bone graft (G), BS-particulate glass ceramic (180-212 μm) Biosilicate(®) (BS), and BS+G-particulate glass ceramic + G. After 45 and 90 days, animals were euthanized and the specimens prepared to be analyzed under light and polarized microscopy, immunohistochemistry, scanning electron microscopy (SEM), and micro-computed tomography (μCT). Results revealed different degradation pattern between both biomaterials, despite the association with bone graft. BS caused a more intense chronic inflammation with foreign body reaction, which led to a difficulty in bone formation. Besides this evidence, SEM and μCT confirmed direct contact between newly formed bone and biomaterial, along with osteopontin and osteocalcin immunolabeling. Bone matrix mineralization was late in BS group but became similar to BO at day 90. These results clearly indicate that further studies about Biosilicate(®) are necessary to identify the factors that resulted in an unfavorable healing response when used in maxillary sinus augmentation.
Collapse
Affiliation(s)
- Rodrigo Ricci Vivan
- Department of Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo - FOB/USP, Al. Octávio Pinheiro Brisola, 9-75, Bauru, SP, 17012-901, Brazil
| | - Carlos Eduardo Mecca
- Oral Biology Master's Program, Sagrado Coração University - USC, Rua Irmã Arminda 10-50, Baur, SP, 17011-160, Brazil
| | - Claudia Cristina Biguetti
- Oral Biology Doctoral's Program, Bauru School of Dentistry, University of São Paulo - FOB/USP, Al. Octávio Pinheiro Brisola, 9-75, Bauru, SP, 17012-901, Brazil
| | - Ana Claudia Muniz Rennó
- Department of Bioscience, Federal University of Sao Paulo, Campus Baixada Santista - UNIFESP, Avenida Ana Costa, 95, Santos, SP, 11060-001, Brazil
| | - Roberta Okamoto
- Department of Basic Sciences, Araçatuba School of Dentistry, São Paulo State University, FOA/UNESP, Rua José Bonifácio 1193, Araçatuba, SP, 16015-050, Brazil
- CNPq (Conselho Nacional de Desenvolvimento Científico e Tecnológico), Brasília, Brazil
| | - Bruno Cavalini Cavenago
- Department of Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo - FOB/USP, Al. Octávio Pinheiro Brisola, 9-75, Bauru, SP, 17012-901, Brazil
| | - Marco Húngaro Duarte
- Department of Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo - FOB/USP, Al. Octávio Pinheiro Brisola, 9-75, Bauru, SP, 17012-901, Brazil
| | - Mariza Akemi Matsumoto
- Department of Basic Sciences, Araçatuba School of Dentistry, São Paulo State University, FOA/UNESP, Rua José Bonifácio 1193, Araçatuba, SP, 16015-050, Brazil.
- Oral Biology Doctoral's Program, Sagrado Coração University, USC, Bauru, Brazil.
| |
Collapse
|
69
|
Lyu X, Li Z, Wang H, Yang X. [Bioactive glass 45S5-silk fibroin membrane supports proliferation and differentiation of human dental pulp stem cells]. Zhonghua Kou Qiang Yi Xue Za Zhi 2015; 50:725-730. [PMID: 26887396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
OBJECTIVE To investigate the effect of bioactivity glass 45S5- silk fibroin(BG45S5- SF) membrane on growth, proliferation and differentiation of human dental pulp stem cells(hDPSC), and to provide new ideas and method for the regeneration of pulp-dentine complex. METHODS hDPSC seed on pure silk fibroin membrane (protein membrane group) and BG45S5-SF membrane with different concentrations(1 000, 5 000 mg/L, composite membrane group A and B, respectively) were prepared, and the materials were incubated in cell culture fluid for 24 h. No material membrane orifice plate was used as blank control group. Contact angle meter was used to measure surface contact angle of protein membrane and composite membrane group(each group had three repeated holes). Cell proliferation was assessed by cell counting kit- 8 on the 4, 7, 14, and 21 days. The state of adhesion and growth of hDPSC on the materials surface was evaluated by scanning electron microscopy and cytoskeleton staining; and alkaline phosphatase (ALP) activity was measured to evaluate the cell differentiation potential. The expression of odontoblastic differentiation-related genes was measured by real-time PCR. RESULTS Surface contact angle of the protein membrane group and composite membrane group A and group B were 89.51° ± 0.12°, 70.32° ± 0.07° and 71.31° ± 0.09° respectively. hDPSC adhered well on each materials surface on the 7, 14, 21 days, ALP activity and differentiation genes of composite membrane group A and B rised more significantly than the blank control group and protein membrane group did (P<0.05). Dentin matrix protein1(DMP- 1), dentin sialoprotein(DSP), ALP, osteocalcin(OC) mRNA expression reached peak on the 14 days in group A, and in group B on the 21 days. Bone sialoprotein(BSP) mRNA expression in both group A and B reached peak on the 21 days. CONCLUSIONS BG45S5- SF membrane is able to support the proliferation and showed the potential of odontoblastic differentiation for hDPSC. This finding suggests that BG45S5-SF membrane was a kind of tissue engineering film material with the regeneration potential for pulp-dentine complex.
Collapse
Affiliation(s)
- Xiaoshuai Lyu
- Department of Digital Dental Center, Key Laboratory of Oral Medicine, Guangzhou Institute of Oral Disease, Stomatology Hospital of Guangzhou Medical University, Guangzhou 510140, China
| | - Zhengmao Li
- Department of Digital Dental Center, Key Laboratory of Oral Medicine, Guangzhou Institute of Oral Disease, Stomatology Hospital of Guangzhou Medical University, Guangzhou 510140, China
| | - Haiyan Wang
- Department of Digital Dental Center, Key Laboratory of Oral Medicine, Guangzhou Institute of Oral Disease, Stomatology Hospital of Guangzhou Medical University, Guangzhou 510140, China
| | - Xuechao Yang
- Department of Digital Dental Center, Key Laboratory of Oral Medicine, Guangzhou Institute of Oral Disease, Stomatology Hospital of Guangzhou Medical University, Guangzhou 510140, China;
| |
Collapse
|
70
|
Yeung CA, Hayashi M. WITHDRAWN: Ceramic inlays for restoring posterior teeth. Cochrane Database Syst Rev 2015; 2015:CD003450. [PMID: 26418289 PMCID: PMC10655183 DOI: 10.1002/14651858.cd003450.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Withdrawn as the review has been superseded by a more up to date version of a Cochrane review of the same title. The editorial group responsible for this previously published document have withdrawn it from publication.
Collapse
Affiliation(s)
- C Albert Yeung
- NHS LanarkshireDepartment of Public HealthKirklandsFallside RoadBothwellUKG71 8BB
| | - Mikako Hayashi
- Osaka University Graduate School of DentistryDepartment of Restorative Dentistry & Endodontology1‐8 Yamadaoka SuitaOsakaJapan565‐0871
| | | |
Collapse
|
71
|
Emoto M, Yoshihisa H, Yano K, Choijamts B, Tsugu H, Tachibana K, Aizawa M. Advanced Chemoembolization by Anti-angiogenic Calcium-Phosphate Ceramic Microspheres Targeting the Vascular Heterogeneity of Cancer Xenografts. Anticancer Res 2015; 35:4757-4764. [PMID: 26254366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The purpose of the present study was to develop an advanced method of anti-angiogenic chemoembolization to target morphological vascular heterogeneity in tumors and further the therapeutic efficacy of cancer treatment. This new chemoembolization approach was designed using resorbable calcium-phosphate ceramic microspheres (CPMs), in a mixture of three different sizes, which were loaded with an anti-angiogenic agent to target the tumor vasculature in highly angiogenic solid tumors in humans in vivo. The human uterine carcinosarcoma cell line, FU-MMT-3, was used in this study because the tumor is highly aggressive and exhibits a poor response to radiotherapy and chemotherapeutic agents that are in current use. CPMs loaded with TNP-470, an anti-angiogenic agent, were injected into FU-MMT-3 xenografts in nude mice three times per week for 8 weeks. The treatment with TNP-470-loaded CPMs of three different diameters achieved a greater suppression of tumor growth in comparison to treatment with single-size TNP-470-loaded CPMs alone, and the control. Severe loss of body weight was not observed in any mice treated with any size of TNP-470-loaded CPMs. These results suggest that treatment with a mixture of differently-sized anti-angiogenic CPMs might be more effective than treatment with CPMs of a single size. This advanced chemoembolization method, which incorporated an anti-angiogenic agent to target the morphological vascular heterogeneity of tumors may contribute to effective treatment of locally advanced or recurrent solid tumors.
Collapse
Affiliation(s)
- Makoto Emoto
- Department of Health and Welfare, International University of Health and Welfare, Sawara-ku, Fukuoka, Japan Division of Gynecology in Preventive Medicine, Fukuoka Sanno Hospital, Sawara-ku, Fukuoka, Japan
| | - Hajime Yoshihisa
- Department of Applied Chemistry, School of Science and Technology, Meiji University, Tama-ku, Kawasaki, Japan
| | - Kyoko Yano
- Department of Pathology, Faculty of Medicine, Fukuoka University, Nanakuma, Jonan-ku, Fukuoka, Japan
| | - Batsuren Choijamts
- Department of Health and Welfare, International University of Health and Welfare, Sawara-ku, Fukuoka, Japan
| | - Hitoshi Tsugu
- Department of Pathology, Faculty of Medicine, Fukuoka University, Nanakuma, Jonan-ku, Fukuoka, Japan
| | - Katsuro Tachibana
- Department of Anatomy, Faculty of Medicine, Fukuoka University, Nanakuma, Jonan-ku, Fukuoka, Japan
| | - Mamoru Aizawa
- Department of Applied Chemistry, School of Science and Technology, Meiji University, Tama-ku, Kawasaki, Japan
| |
Collapse
|
72
|
Abstract
Bone is a unique organ composed of mineralized hard tissue, unlike any other body part. The unique manner in which bone can constantly undergo self-remodeling has created interesting clinical approaches to the healing of damaged bone. Healing of large bone defects is achieved using implant materials that gradually integrate with the body after healing is completed. Such strategies require a multidisciplinary approach by material scientists, biological scientists, and clinicians. Development of materials for bone healing and exploration of the interactions thereof with the body are active research areas. In this review, we explore ongoing developments in the creation of materials for regenerating hard tissues.
Collapse
Affiliation(s)
- Swapan Kumar Sarkar
- Institute of Tissue Regeneration, Soonchunhyang University College of Medicine, Cheonan, Korea
| | - Byong Taek Lee
- Institute of Tissue Regeneration, Soonchunhyang University College of Medicine, Cheonan, Korea
| |
Collapse
|
73
|
Du B, Liu W, Deng Y, Li S, Liu X, Gao Y, Zhou L. Angiogenesis and bone regeneration of porous nano-hydroxyapatite/coralline blocks coated with rhVEGF165 in critical-size alveolar bone defects in vivo. Int J Nanomedicine 2015; 10:2555-65. [PMID: 25848271 PMCID: PMC4386782 DOI: 10.2147/ijn.s78331] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
To improve the regenerative performance of nano-hydroxyapatite/coralline (nHA/coral) block grafting in a canine mandibular critical-size defect model, nHA/coral blocks were coated with recombinant human vascular endothelial growth factor(165) (rhVEGF) via physical adsorption (3 μg rhVEGF165 per nHA/coral block). After the nHA/coral blocks and VEGF/nHA/coral blocks were randomly implanted into the mandibular box-shaped defects in a split-mouth design, the healing process was evaluated by histological observation and histomorphometric and immunohistological analyses. The histological evaluations revealed the ingrowth of newly formed blood vessels and bone at the periphery and cores of the blocks in both groups at both 3 and 8 weeks postsurgery, respectively. In the histomorphometric analysis, the VEGF/nHA/coral group exhibited a larger quantity of new bone formation at 3 and 8 weeks postsurgery. The percentages of newly formed bone within the entire blocks in the VEGF/nHA/coral group were 27.3% ± 8.1% and 39.3% ± 12.8% at 3 weeks and 8 weeks, respectively, and these values were slightly greater than those of the nHA/coral group (21.7% ± 3.0% and 32.6% ± 10.3%, respectively), but the differences were not significant (P>0.05). The immunohistological evaluations revealed that the neovascular density in the VEGF/nHA/coral group (146 ± 32.9 vessel/mm(2)) was much greater than that in the nHA/coral group (105 ± 51.8 vessel/mm(2)) at the 3-week time point (P<0.05), but no significant difference was observed at the 8-week time point (341 ± 86.1 and 269 ± 50.7 vessel/mm(2), respectively, P>0.05). The present study indicated that nHA/coral blocks might be optimal scaffolds for block grafting in critical-size mandibular defects and that additional VEGF coating via physical adsorption can promote angiogenesis in the early stage of bone healing, which suggests that prevascularized nHA/coral blocks have significant potential as a bioactive material for bone regeneration in large-scale alveolar defects.
Collapse
Affiliation(s)
- Bing Du
- Department of Oral Implantology, Guangdong Provincial Stomatological Hospital, Southern Medical University, Guangzhou, People’s Republic of China
- Center of Stomatology, The First People’s Hospital of Foshan, Foshan, Guangdong, People’s Republic of China
| | - Weizhen Liu
- Department of Oral Implantology, Guangdong Provincial Stomatological Hospital, Southern Medical University, Guangzhou, People’s Republic of China
| | - Yue Deng
- Department of Oral Implantology, Guangdong Provincial Stomatological Hospital, Southern Medical University, Guangzhou, People’s Republic of China
- Department of Oral and Maxillofacial Surgery, Qingdao Stomatological Hospital, Qingdao, People’s Republic of China
| | - Shaobing Li
- Department of Oral Implantology, Guangdong Provincial Stomatological Hospital, Southern Medical University, Guangzhou, People’s Republic of China
| | - Xiangning Liu
- Department of Stomatology, The First Affiliated Hospital of Jinan University, Guangzhou, People’s Republic of China
| | - Yan Gao
- Department of Oral Implantology, Guangdong Provincial Stomatological Hospital, Southern Medical University, Guangzhou, People’s Republic of China
| | - Lei Zhou
- Department of Oral Implantology, Guangdong Provincial Stomatological Hospital, Southern Medical University, Guangzhou, People’s Republic of China
| |
Collapse
|
74
|
Abstract
This study assessed marginal leakage and fracture resistance of computer-aided design/computer-aided manufacturing (CAD/CAM) fabricated ceramic crowns with intracoronal extensions into the pulp chambers of endodontically treated teeth (endocrowns) using either feldspathic porcelain (CEREC Blocks [CB], Sirona Dental Systems GmbH, Bensheim, Germany), lithium disilicate (e.max [EX], Ivoclar Vivadent, Schaan, Liechtenstein), or resin nanoceramic (Lava Ultimate [LU], 3M ESPE, St Paul, MN, USA).). Thirty extracted human permanent maxillary molars were endodontically treated. Standardized preparations were done with 2-mm intracoronal extensions of the endocrowns into the pulp chamber. Teeth were divided into three groups (n=10); each group was restored with standardized CAD/CAM fabricated endocrowns using one of the three tested materials. After cementation with resin cement, specimens were stored in distilled water at 37°C for one week, subjected to thermocycling, and immersed in a 5% methylene-blue dye solution for 24 hours. A compressive load was applied at 35 degrees to long axis of the teeth using a universal testing machine until failure. Failure load was recorded, and specimens were examined under a stereomicroscope for modes of failure and microleakage. Results were analyzed using one-way analysis of variance and Bonferroni post hoc multiple comparison tests (α=0.05). LU showed significantly (p<0.05) higher fracture resistance and more favorable fracture mode (ie, fracture of the endocrown without fracture of tooth) as well as higher dye penetration than CB and EX. In conclusion, although using resin nanoceramic blocks for fabrication of endocrowns may result in better fracture resistance and a more favorable fracture mode than other investigated ceramic blocks, more microleakage may be expected with this material.
Collapse
|
75
|
Zandinejad A, Lin WS, Atarodi M, Abdel-Azim T, Metz MJ, Morton D. Digital workflow for virtually designing and milling ceramic lithium disilicate veneers: a clinical report. Oper Dent 2015; 40:241-6. [PMID: 25706612 DOI: 10.2341/13-291-s] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Laminate veneers have been routinely used to restore and enhance the appearance of natural dentition. The traditional pathway for fabricating veneers consisted of making conventional polyvinyl siloxane impressions, producing stone casts, and fabricating final porcelain prostheses on stone dies. Pressed ceramics have successfully been used for laminate veneer fabrication for several years. Recently, digital computer-aided design/computer-aided manufacturing scanning has become commercially available to make a digital impression that is sent electronically to a dental laboratory or a chairside milling machine. However, technology has been developed to allow digital data acquisition in conjunction with electronically transmitted data that enables virtual design of restorations and milling at a remote production center. Following the aforementioned workflow will provide the opportunity to fabricate a physical cast-free restoration. This new technique has been reported recently for all-ceramic IPS e.max full-coverage pressed-ceramic restorations. However, laminate veneers are very delicate and technique-sensitive restorations when compared with all-ceramic full-coverage ones made from the same material. Complete digital design and fabrication of multiple consecutive laminate veneers seems to be very challenging. This clinical report presents the digital workflow for the virtual design and fabrication of multiple laminate veneers in a patient for enhancing the esthetics of his maxillary anterior teeth. A step-by-step process is presented with a discussion of the advantages and disadvantages of this novel technique. Additionally, the use of lithium disilicate ceramic as the material of choice and the rationale for such a decision is discussed.
Collapse
|
76
|
Abstract
The aim of this study was to evaluate the internal fit, marginal adaptation, and bond strengths of inlays made of computer-aided design/computer-aided manufacturing feldspathic ceramic and polymer-infiltrated ceramic. Twenty molars were randomly selected and prepared to receive inlays that were milled from both materials. Before cementation, internal fit was achieved using the replica technique by molding the internal surface with addition silicone and measuring the cement thicknesses of the pulpal and axial walls. Marginal adaptation was measured on the occlusal and proximal margins of the replica. The inlays were then cemented using resin cement (Panavia F2.0) and subjected to two million thermomechanical cycles in water (200 N load and 3.8-Hz frequency). The restored teeth were then cut into beams, using a lathe, for microtensile testing. The contact angles, marginal integrity, and surface patterns after etching were also observed. Statistical analysis was performed using two-way repeated measures analysis of variance (p<0.05), the Tukey test for internal fit and marginal adaptation, and the Student t-test for bond strength. The failure types (adhesive or cohesive) were classified on each fractured beam. The results showed that the misfit of the pulpal walls (p=0.0002) and the marginal adaptation (p=0.0001) of the feldspathic ceramic were significantly higher when compared to those of the polymer-infiltrated ceramic, while the bond strength values of the former were higher when compared to those of the latter. The contact angle of the polymer-infiltrated ceramic was also higher. In the present study, the hybrid ceramic presented improved internal and marginal adaptation, but the bond strengths were higher for the feldspathic ceramic.
Collapse
|
77
|
Campana V, Milano G, Pagano E, Barba M, Cicione C, Salonna G, Lattanzi W, Logroscino G. Bone substitutes in orthopaedic surgery: from basic science to clinical practice. J Mater Sci Mater Med 2014; 25:2445-61. [PMID: 24865980 PMCID: PMC4169585 DOI: 10.1007/s10856-014-5240-2] [Citation(s) in RCA: 582] [Impact Index Per Article: 58.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Accepted: 05/09/2014] [Indexed: 05/04/2023]
Abstract
Bone substitutes are being increasingly used in surgery as over two millions bone grafting procedures are performed worldwide per year. Autografts still represent the gold standard for bone substitution, though the morbidity and the inherent limited availability are the main limitations. Allografts, i.e. banked bone, are osteoconductive and weakly osteoinductive, though there are still concerns about the residual infective risks, costs and donor availability issues. As an alternative, xenograft substitutes are cheap, but their use provided contrasting results, so far. Ceramic-based synthetic bone substitutes are alternatively based on hydroxyapatite (HA) and tricalcium phosphates, and are widely used in the clinical practice. Indeed, despite being completely resorbable and weaker than cortical bone, they have exhaustively proved to be effective. Biomimetic HAs are the evolution of traditional HA and contains ions (carbonates, Si, Sr, Fl, Mg) that mimic natural HA (biomimetic HA). Injectable cements represent another evolution, enabling mininvasive techniques. Bone morphogenetic proteins (namely BMP2 and 7) are the only bone inducing growth factors approved for human use in spine surgery and for the treatment of tibial nonunion. Demineralized bone matrix and platelet rich plasma did not prove to be effective and their use as bone substitutes remains controversial. Experimental cell-based approaches are considered the best suitable emerging strategies in several regenerative medicine application, including bone regeneration. In some cases, cells have been used as bioactive vehicles delivering osteoinductive genes locally to achieve bone regeneration. In particular, mesenchymal stem cells have been widely exploited for this purpose, being multipotent cells capable of efficient osteogenic potential. Here we intend to review and update the alternative available techniques used for bone fusion, along with some hints on the advancements achieved through the experimental research in this field.
Collapse
Affiliation(s)
- V. Campana
- Department of Orthopaedics and Traumatology, Università Cattolica del Sacro Cuore, L.go F. Vito 1, 00168 Rome, Italy
| | - G. Milano
- Department of Orthopaedics and Traumatology, Università Cattolica del Sacro Cuore, L.go F. Vito 1, 00168 Rome, Italy
| | - E. Pagano
- Department of Orthopaedics and Traumatology, Università Cattolica del Sacro Cuore, L.go F. Vito 1, 00168 Rome, Italy
| | - M. Barba
- Institute of Anatomy and Cell Biology, Università Cattolica del Sacro Cuore, Rome, Italy
| | - C. Cicione
- Institute of Anatomy and Cell Biology, Università Cattolica del Sacro Cuore, Rome, Italy
| | - G. Salonna
- Department of Orthopaedics and Traumatology, Università Cattolica del Sacro Cuore, L.go F. Vito 1, 00168 Rome, Italy
| | - W. Lattanzi
- Institute of Anatomy and Cell Biology, Università Cattolica del Sacro Cuore, Rome, Italy
- Latium Musculoskeletal Tissue Bank, Rome, Italy
| | - G. Logroscino
- Department of Orthopaedics and Traumatology, Università Cattolica del Sacro Cuore, L.go F. Vito 1, 00168 Rome, Italy
| |
Collapse
|
78
|
Abebe LS, Smith JA, Narkiewicz S, Oyanedel-Craver V, Conaway M, Singo A, Amidou S, Mojapelo P, Brant J, Dillingham R. Ceramic water filters impregnated with silver nanoparticles as a point-of-use water-treatment intervention for HIV-positive individuals in Limpopo Province, South Africa: a pilot study of technological performance and human health benefits. J Water Health 2014; 12:288-300. [PMID: 24937223 DOI: 10.2166/wh.2013.185] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Waterborne pathogens present a significant threat to people living with the human immunodeficiency virus (PLWH). This study presents a randomized, controlled trial that evaluates whether a household-level ceramic water filter (CWF) intervention can improve drinking water quality and decrease days of diarrhea in PLWH in rural South Africa. Seventy-four participants were randomized in an intervention group with CWFs and a control group without filters. Participants in the CWF arm received CWFs impregnated with silver nanoparticles and associated safe-storage containers. Water and stool samples were collected at baseline and 12 months. Diarrhea incidence was self-reported weekly for 12 months. The average diarrhea rate in the control group was 0.064 days/week compared to 0.015 days/week in the intervention group (p < 0.001, Mann-Whitney). Median reduction of total coliform bacteria was 100% at enrollment and final collection. CWFs are an acceptable technology that can significantly improve the quality of household water and decrease days of diarrhea for PLWH in rural South Africa.
Collapse
Affiliation(s)
- Lydia Shawel Abebe
- Department of Civil and Environmental Engineering, University of Virginia, PO Box 400742, 351 McCormick Road, Thornton Hall, Rm. B228, Charlottesville, VA 22908, USA
| | - James A Smith
- Department of Civil and Environmental Engineering, University of Virginia, PO Box 400742, 351 McCormick Road, Thornton Hall, Rm. B228, Charlottesville, VA 22908, USA
| | - Sophia Narkiewicz
- Department of Civil Engineering, University of Rhode Island, Bliss Hall 213, Kingston, RI 02881, USA
| | - Vinka Oyanedel-Craver
- Department of Civil Engineering, University of Rhode Island, Bliss Hall 213, Kingston, RI 02881, USA
| | - Mark Conaway
- Department of Public Health Sciences, Public Health Sciences Hospital West, University of Virginia, PO Box 800717, 3181, Charlottesville, VA, USA
| | - Alukhethi Singo
- Department of Microbiology, University of Venda, Department of Chemistry, University of Venda, Private Bag X5050, Thohoyandou 0950, Limpopo Province, South Africa
| | - Samie Amidou
- Department of Microbiology, University of Venda, Department of Chemistry, University of Venda, Private Bag X5050, Thohoyandou 0950, Limpopo Province, South Africa
| | - Paul Mojapelo
- Department of Microbiology, University of Venda, Department of Chemistry, University of Venda, Private Bag X5050, Thohoyandou 0950, Limpopo Province, South Africa
| | - Julia Brant
- Department of Medicine, University of Virginia, PO Box 801379, Charlottesville, VA, USA E-mail:
| | - Rebecca Dillingham
- Department of Medicine, University of Virginia, PO Box 801379, Charlottesville, VA, USA E-mail:
| |
Collapse
|
79
|
Abstract
By definition and general agreement, smart materials are materials that have properties which may be altered in a controlled fashion by stimuli, such as stress, temperature, moisture, pH, and electric or magnetic fields. There are numerous types of smart materials, some of which are already common. Examples include piezoelectric materials, which produce a voltage when stress is applied or vice versa, shape memory alloys or shape memory polymers which are thermoresponsive, and pH sensitive polymers which swell or shrink as a response to change in pH. Thus, smart materials respond to stimuli by altering one or more of their properties. Smart behaviour occurs when a material can sense some stimulus from its environment and react to it in a useful, reliable, reproducible, and usually reversible manner. These properties have a beneficial application in various fields including dentistry. Shape memory alloys, zirconia, and smartseal are examples of materials exhibiting a smart behavior in dentistry. There is a strong trend in material science to develop and apply these intelligent materials. These materials would potentially allow new and groundbreaking dental therapies with a significantly enhanced clinical outcome of treatments.
Collapse
Affiliation(s)
- Vijetha Badami
- Department of Conservative Dentistry and Endodontics, A.M.E'S Dental College, Hospital and Research centre, Bijengere Road, Raichur 584103, India
| | - Bharat Ahuja
- Department of Conservative Dentistry and Endodontics, A.M.E'S Dental College, Hospital and Research centre, Bijengere Road, Raichur 584103, India
| |
Collapse
|
80
|
Baeza A, Arcos D, Vallet-Regí M. Thermoseeds for interstitial magnetic hyperthermia: from bioceramics to nanoparticles. J Phys Condens Matter 2013; 25:484003. [PMID: 24200980 DOI: 10.1088/0953-8984/25/48/484003] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The development of magnetic materials for interstitial hyperthermia treatment of cancer is an ever evolving research field which provides new alternatives to antitumoral therapies. The development of biocompatible magnetic materials has resulted in new biomaterials with multifunctional properties, which are able to adapt to the complex scenario of tumoral processes. Once implanted or injected in the body, magnetic materials can behave as thermoseeds under the effect of AC magnetic fields. Magnetic bioceramics aimed to treat bone tumors and magnetic nanoparticles are among the most studied thermoseeds, and supply different solutions for the different scenarios in cancerous processes. This paper reviews some of the biomaterials used for bone cancer treatment and skeletal reinforcing, as well as the more complex topic of magnetic nanoparticles for intracellular targeting and hyperthermia.
Collapse
|
81
|
Prol-García MJ, Pintado J. Effectiveness of probiotic Phaeobacter bacteria grown in biofilters against Vibrio anguillarum infections in the rearing of Turbot (Psetta maxima) larvae. Mar Biotechnol (NY) 2013; 15:726-738. [PMID: 23917459 DOI: 10.1007/s10126-013-9521-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Accepted: 06/04/2013] [Indexed: 06/02/2023]
Abstract
The rearing environment of first-feeding turbot larvae, usually with high larvae densities and organic matter concentrations, may promote the growth of opportunistic pathogenic Vibrionaceae bacteria, compromising the survival of the larvae. The aim of this study was to assess the effectiveness of the biofilm-forming probiotic Phaeobacter 27-4 strain grown on a ceramic biofilter (probiofilter) in preventing Vibrio anguillarum infections in turbot larvae. In seawater with added microalgae and maintained under turbot larvae rearing conditions, the probiofilter reduced the total Vibrionaceae count and the concentration of V. anguillarum, which was undetectable after 144 h by real-time PCR. The probiofilter also improved the survival of larvae challenged with V. anguillarum, showing an accumulated mortality similar to that of uninfected larvae (35-40 %) and significantly (p < 0.05) lower than that of infected larvae with no probiofilter (76 %) due to a decrease in the pathogen concentration and in total Vibrionaceae. Furthermore, the probiofilter improved seawater quality by decreasing turbidity. Phaeobacter 27-4 released from the probiofilters was able to survive in the seawater for at least 11 days. The bacterial diversity in the larvae, analysed by denaturing gradient gel electrophoresis, was low, as in the live prey (rotifers), and remained unchanged in the presence of V. anguillarum or the probiofilter; however, the probiofilter reduced the bacterial carrying capacity of the seawater in the tanks. Phaeobacter-grown biofilters can constantly inoculate probiotics into rearing tanks and are therefore potentially useful for bacterial control in both open and recirculating industrial units.
Collapse
Affiliation(s)
- María J Prol-García
- Instituto de Investigacións Mariñas (IIM-CSIC), Eduardo Cabello 6, 36208, Vigo, Spain,
| | | |
Collapse
|
82
|
Abstract
Revision rates of total hip arthroplasty have decreased after introducing total hip arthroplasty (THA) using ceramic component, since ceramic components could reduce components wear and osteolysis. The fracture of a ceramic component is a rare but potentially serious event. Thus, ceramic on polyethylene articulation is gradually spotlighted to reduce ceramic component fracture. There are a few recent reports of ceramic head fracture with polyethylene liner. Herein, we describe a case of a ceramic head component fracture with polyethylene liner. The fractured ceramic head was 28 mm short neck with conventional polyethylene liner. We treated the patient by total revision arthroplasty using 4th generation ceramic on ceramic components.
Collapse
Affiliation(s)
- Jae-Hwi Nho
- Department of Orthopaedic Surgery, Soonchunhyang University Hospital Cheonan, 31 Soonchunhyang 6-gil, Dongnam-gu, Cheonan 330-721, Korea.
| | | | | | | | | |
Collapse
|
83
|
Zywicka B, Karuga E, Rutkowska-Gorczyca M, Garcarek J, Jaegermann Z, Michałowski S. [Examination of influence of microstructure of grafts on TiO2 base on the process of bone tissue forming]. Polim Med 2013; 43:81-91. [PMID: 24044288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023] Open
Abstract
AIM OF THE STUDY Evaluation of the influence of the introduced structure modification in porous ceramic grafts on TiO2 base on overgrowing with bone tissue, in examinations with use of scanning microscopy and X-rays was the subject of the examinations. MATERIAL AND METHOD New ceramic materials based on TiO2 with high values of mechanical resistance, large sintering degree and biocompatibility in in vitro conditions were prepared. Those properties cause that they are worth interest as potential osteosubstitutive materials. Two kinds of grafts were created from ceramics based on TiO2: with compact and porous structure. The introduced structure modification - macroporosity - had the purpose to give osteoconductive properties to the grafts, to evoke processes favorable for bone tissue forming. In examinations of the local reaction of bone tissue after implantation of the formed porous grafts, degree of their osteointegration, the essential issue is the evaluation of the settling of the inner spaces with supporting tissues. Samples of the tested compact and porous materials in the form of cylinders were implanted in femoral bones of rabbits for a period till 6 months. The surfaces of grafts and the degree of their settling with supporting tissues were evaluated in cross-sections of the implants with light and scanning microscopic methods and they were confirmed in X-ray tests. RESULTS Analysis of the obtained data showed that, the surface of solid ceramic on TiO2 base was covered mainly with increasing with a time of observation quantities of extracellular substance and lamellas of bone. The macrporous structure of porous ceramic on TiO2 base enabled settling of the inner spaces of graft with supporting tissue cells, partly in the 1st month, more intensively in the 3rd and it was not completed in the 6th month after implantation. CONCLUSIONS Porous grafts in the form of ceramic foam on TiO2 base showed osteoconductive properties, though process of colonization after 6th month observation was not completed and the condition of the cells inside of the implant was reduced.
Collapse
Affiliation(s)
- Bogusława Zywicka
- Zakład Chirurgii Eksperymentalnej i Badania Biomateriałów Uniwersytetu Medycznego we Wrocławiu, Polska.
| | | | | | | | | | | |
Collapse
|
84
|
Sauro S, Osorio R, Watson TF, Toledano M. Therapeutic effects of novel resin bonding systems containing bioactive glasses on mineral-depleted areas within the bonded-dentine interface. J Mater Sci Mater Med 2012; 23:1521-1532. [PMID: 22466816 DOI: 10.1007/s10856-012-4606-6] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2011] [Accepted: 02/27/2012] [Indexed: 05/31/2023]
Abstract
This study aimed in evaluating the effects of two experimental resin bonding systems containing conventional Bioglass 45S5 (BAG) or Zinc-polycarboxylated bioactive glass (BAG-Zn) micro-fillers on the resin-bonded dentine interface after storage in a simulated body fluid solution (SBFS). Three resin bonding systems were formulated: Resin-A: (BAG containing); Resin-B; (BAG-Zn containing); Resin-C (no filler). The ability of the experimental resins to evoke apatite formation was evaluated using confocal Raman spectroscopy. Acid-etched dentine specimens were bonded, and prepared for AFM/nano-indentation analysis in a fully-hydrated status to evaluate the modulus of elasticity (Ei) and hardness (Hi) across the interface at different SBFS storage periods. Further resin-dentine specimens were tested for microtensile bond strength after 24 h or 3 months of SBFS storage. SEM examination was performed after de-bonding and confocal laser microscopy was used to evaluate the ultramorphology of the interfaces and micropermeability. The resin A and B showed a consistent presence of apatite (967 cm(-1)), reduced micropermeability within the resin-dentine interface and a significant increase of the Ei and Hi along the bonded-dentine interface after prolonged SBFS storage. Bond strength values were affected by the resin system (P < 0.0001) and by storage time (P < 0.0001) both after 24 h and 3 months of SBFS storage. In conclusion, resin bonding systems containing bioactive fillers may a have therapeutic effect on the nano-mechanical properties and sealing ability of mineral-depleted resin-dentine interface.
Collapse
Affiliation(s)
- Salvatore Sauro
- Biomaterials, Biomimetics and Biophotonics, King's College London Dental Institute, Guy's Dental Hospital, London, England, UK.
| | | | | | | |
Collapse
|
85
|
Abstract
The development of the suture anchor has played a pivotal role in the transition from open to arthroscopic techniques of the shoulder. Various suture anchors have been manufactured that help facilitate the ability to create a soft tissue to bone repair. Because of reported complications of loosening, migration, and chondral injury with metallic anchors, bioabsorbable anchors have become increasingly used among orthopaedic surgeons. In this review, the authors sought to evaluate complications associated with bioabsorbable anchors in or about the shoulder and understand these in the context of the total number of bioabsorbable anchors placed. In 2008, 10 bioabsorbable anchor-related complications were reported to the US Food and Drug Administration. The reported literature complications of bioabsorbable anchors implanted about the shoulder include glenoid osteolysis, synovitis, and chondrolysis. These potential complications should be kept in mind when forming a differential diagnosis in a patient in whom a bioabsorbable anchor has been previously used. These literature reports, which amount to but a fraction of the total bioabsorbable anchors implanted in the shoulder on a yearly basis, underscore the relative safety and successful clinical results with use of bioabsorbable suture anchors. Product development continues with newer composites such as PEEK (polyetheretherketone) and calcium ceramics (tricalcium phosphate) in an effort to hypothetically create a mechanically stable construct with and improve biocompatibility of the implant. Bioabsorbable anchors remain a safe, reproducible, and consistent implant to secure soft tissue to bone in and about the shoulder. Meticulous insertion technique must be followed in using bioabsorbable anchors and may obviate many of the reported complications found in the literature. The purpose of this review is to provide an overview of the existing literature as it relates to the rare complications seen with use of bioabsorbable suture anchors in the shoulder.
Collapse
Affiliation(s)
- Aman Dhawan
- Division of Sports Medicine, Rush University Medical Center, 1611 W Harrison, Suite 300, Chicago, IL 60612, USA
| | | | | | | | | |
Collapse
|
86
|
Civinini R, De Biase P, Carulli C, Matassi F, Nistri L, Capanna R, Innocenti M. The use of an injectable calcium sulphate/calcium phosphate bioceramic in the treatment of osteonecrosis of the femoral head. Int Orthop 2012; 36:1583-8. [PMID: 22426934 DOI: 10.1007/s00264-012-1525-6] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2012] [Accepted: 03/01/2012] [Indexed: 02/06/2023]
Abstract
PURPOSE The purpose of our study is to describe the rationale, the surgical technique and the early clinical and radiographic results of the treatment of patients with early stage osteonecrosis of the femoral head (ONFH) by performing: core decompression, injection of autologous bone marrow concentrate and the use of a new composite injectable bone substitute (PRO-DENSE(®)), as a mechanical supplementation associated with decompression. METHODS The study included 37 hips (31 patients, 14 females, 17 males; mean age 43.9 years, range 24-56 years) with stages IC-IIIA ONFH. The outcome was determined by the changes in the Harris hip score (HHS), by progression in radiographic stages and by the need for hip replacement. The mean follow-up was 20.6 months (range 12-32 months). RESULTS At final follow-up the mean HHS increased from 68 points pre-operatively to 86 points post-operatively. The radiological results showed that 29 hips (78.4 %) improved or had no further collapse. The overall clinical success rate of the procedure was 86.5 %, with three conversions to THA, and a failure rate of only 3.3 % in the pre-collapse group. CONCLUSIONS We are encouraged by these early results using core decompression, injection of the autologous bone marrow concentrate and backfilling the defect with an injectable bioceramic for the treatment of early stages of ONFH; as far as a conclusion can be drawn from the current data, this treatment seems to relieve hip pain and prevent the progression of ONFH in the majority of the cases.
Collapse
Affiliation(s)
- Roberto Civinini
- Department of Special Surgical Science, University of Florence, C.T.O. Largo P. Palagi 1, 50139, Firenze, Italy.
| | | | | | | | | | | | | |
Collapse
|
87
|
Shao H, Shao J, Bian H, Zhao Q, Zhou Q, Qi J, Zhu Y, Wang J, Qian N, Chen B, Deng L. OIC-A006-loaded true bone ceramic heals rabbit critical-sized segmental radial defect. Pharmazie 2012; 67:247-252. [PMID: 22530307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
It has been reported that OIC-A006, an osteogenically inducible compound, is able to promote osteogenesis in vitro and in vivo. In this study, we used a rabbit critical-sized segmental radial defect model (CSD) (15 mm) to analyse the osteogenic activity of OIC-A006 in non-cell-seeded tissue engineering bone substitutes. The scaffold carrier was bovine sintered bone "true bone ceramic (TBC)". OIC-A006 was delivered by PLGA (D,L-lactide-co-glycolide acid) microspheres. Drug-free PLGA microspheres and rhBMP-2-loaded PLGA microspheres were used as negative and positive control groups, respectively. Three kinds of composite were fabricated by coupling TBC, type-I collagen and the corresponding microspheres. The animals were randomly divided into 4 groups: (1) Group A: defect only, (2) group B:TBC/Collagen/drug-free-microspheres, (3) group C:TBC/Collagen/ OIC-A006-microspheres, (4) group D: TBC/Collagen/rhBMP-2-microspheres. The samples were analysed by histology, X-ray,microcomputed tomography (micro-CT), and biomechanical analyses. The results showed that OIC-A006 promoted bone regeneration to a remarkable extent. It is suggested that the application of OIC-A006 might be a valuable method in bone tissue engineering for healing large segmental defects of long bones. However, the biomechanical strength was a little inferior to that of BMPs.
Collapse
Affiliation(s)
- Huarong Shao
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases with Integrated Chinese-Western Medicine, Shanghai Institute of Traumatology and Orthopaedics, Department of Orthopaedics, Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
88
|
Koch KA, Brave DG. Bioceramics, part I: the clinician's viewpoint. Dent Today 2012; 31:130-135. [PMID: 22360119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
|
89
|
Abstract
Autologous bone is used very often in the treatment of fresh fractures, delayed unions and non-unions. Alternatives have included allografts and in recent years also demineralized bone matrix. The growing availability of good synthetic bone grafts and their advantages in safety and avoiding donor-site morbidity are the reasons that these products are being used more and more. There are on the market a wide variety of substitutes with different capabilities. Nevertheless autologous bone graft is still considered as the gold standard and will be discussed here in that context. Osteoconductive, osteogenic and osteoinductive products will also be classified and their advantages and disadvantages described.
Collapse
Affiliation(s)
- Gerald Zimmermann
- Theresienkrankenhaus Mannheim, Department of Trauma and Orthopaedic Surgery, University of Heidelberg, Germany.
| | | |
Collapse
|
90
|
Bittle RJ, Bittle CC. The ancient use of faïence in paediatric illness. S Afr Med J 2011; 101:384-385. [PMID: 21920072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2010] [Accepted: 11/08/2010] [Indexed: 05/31/2023] Open
|
91
|
Yu XQ, An YB, Luan QX. [Effects of bio-glass in subgingival scaling and root planing]. Beijing Da Xue Xue Bao Yi Xue Ban 2011; 43:40-43. [PMID: 21321617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
OBJECTIVE To evaluate the effect of locally applied bio-glass on the teeth hypersentivity and periodontal recovery after subgingival scaling and root planing. METHODS In this double blind study, 60 patients with chronic periodontitis were included and were randomly divided into four groups of 15 patients: bio-glass powder and bio-glass paste group (Po+Pa), bio-glass powder group (Po), bio-glass paste group (Pa) and control group. Powder was applied in pockets after subgingival scaling and root planning (SRP) and paste was used as toothpaste for 6 weeks. Periodontal indices and the severity of tooth hypersensitivity were recorded. RESULTS Obvious mitigation of tooth hypersensitivity was observed in bio-glass powder or paste applied patients within the fist three weeks after SRP. Only few patients presented teeth hypersensitivity in the 6th week after SRP. In the 6th week after SRP, bleeding index significantly decreased in bio-glass powder or paste applied patients. More pocket depth and clinical attachment level reduction was found in bio-glass powder applied patients. Application of bio-glass powder or paste improved clinical attachment level in the 3rd month after SRP. CONCLUSION The hypersensitivity after subgingival scaling could be relieved without any treatment in 6 weeks, while the bio-glass powder and the 7% bio-glass paste could reduce the prevalence and the severity of it. Further more, bio-glass also improved the clinical outcomes of subgingival scaling via its bacteriostatic action.
Collapse
Affiliation(s)
- Xiao qian Yu
- Department of Periodontology, Peking University School and Hospital of Stomatology, Beijing 100081, China
| | | | | |
Collapse
|
92
|
Kowalczewski JB, Milecki M, Wielopolski A, Slósarczyk A, Marczak D, Okoń T. [Usefulness of HA+beta-TCP in bone defects repair during revision hip and knee arthroplasty]. Chir Narzadow Ruchu Ortop Pol 2010; 75:348-352. [PMID: 21648152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
BACKGROUND Bone deficiency can present a surgical challenge during revision total hip and knee arthroplasty. The amount of bone grafts available for surgical purposes is insufficient. Synthetic bone substitutes can eliminate the risk of infection transmission. The purpose of the present study was to evaluate the clinical and radiographic outcomes of revision hip and knee arthroplasty with use of an impaction bone-grafting with HA+beta-TCP in reconstruction of bone defects. MATERIALS AND METHODS 20 total hip revision (THR) and 10 total knee revision (TKR) were performed in 30 patients where impaction bone-grafting technique with HA+beta-TCP was used. Clinical, radiographic and CT results were assessed. Mean follow-up was 21 (11-48) months for THR and 22 (10-46) months. RESULTS Loosening was seen in 2 cups. In one case the reoperation was performed. In the second due to massive bone loss the prosthesis was removed. No another acetabular and stem components required revision surgery. There were no knee implant migration or loosening observed. The mean total HSS score was 45.3 preoperatively and 71.5 postoperatively. The mean CRS score was 35.7 preoperatively and 73.4 postoperatively. CONCLUSIONS The use of HA+beta-TCP with bone grafts impaction is a good method of bone defect reconstruction and can provide good short-term clinical results in revision hip and knee arthroplasty.
Collapse
Affiliation(s)
- Jacek B Kowalczewski
- Klinika Ortopedii i Chorób Zapalnych Narzadu Ruchu, Centrum Medyczne Kształcenia Podyplomowego im. prof. Adama Grucy w Otwocku.
| | | | | | | | | | | |
Collapse
|
93
|
Nandi SK, Roy S, Mukherjee P, Kundu B, De DK, Basu D. Orthopaedic applications of bone graft & graft substitutes: a review. Indian J Med Res 2010; 132:15-30. [PMID: 20693585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2023] Open
Abstract
Treatment of delayed union, malunion, and nonunion is a challenge to the orthopaedic surgeons in veterinary and human fields. Apart from restoration of alignment and stable fixation, in many cases adjunctive measures such as bone-grafting or use of bone-graft substitutes are of paramount importance. Bone-graft materials usually have one or more components: an osteoconductive matrix, which acts as scaffold to new bone growth; osteoinductive proteins, which support mitogenesis of undifferentiated cells; and osteogenic cells, which are capable of forming bone in the appropriate environment. Autologous bone remains the "gold standard" for stimulating bone repair and regeneration, but its availability may be limited and the procedure to harvest the material is associated with complications. Bone-graft substitutes can either substitute autologous bone graft or expand an existing amount of autologous bone graft. We review the currently available bone graft and graft substitutes for the novel therapeutic approaches in clinical setting of orthopaedic surgery.
Collapse
Affiliation(s)
- S K Nandi
- Department of Veterinary Surgery & Radiology, West Bengal University of Animal & Fishery Sciences, Kolkata, India.
| | | | | | | | | | | |
Collapse
|
94
|
Oliveira P, Ribeiro DA, Pipi EF, Driusso P, Parizotto NA, Renno ACM. Low level laser therapy does not modulate the outcomes of a highly bioactive glass-ceramic (Biosilicate) on bone consolidation in rats. J Mater Sci Mater Med 2010; 21:1379-1384. [PMID: 19943088 DOI: 10.1007/s10856-009-3945-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2009] [Accepted: 11/12/2009] [Indexed: 05/28/2023]
Abstract
The main purpose of the present work was to evaluate if low level laser therapy (LLLT) can improve the effects of novel fully-crystallized glass-ceramic (Biosilicate) on bone consolidation in tibial defects of rats. Forty male Wistar rats with tibial bone defects were used. Animals were divided into four groups: group bone defect control (CG); group bone defect filled with Biosilicate (BG); group bone defect filled with Biosilicate, irradiated with LLLT, at 60 J cm(-2) (BG 60) and group bone defect filled with Biosilicate, irradiated with LLLT, at 120 J cm(-2) (BG 120). A low-energy GaAlAs 830 nm, CW, 0.6 mm beam diameter, 100 W cm(-2), 60 and 120 J cm(-2) was used in this study. Laser irradiation was initiated immediately after the surgery procedure and it was performed every 48 h for 14 days. Fourteen days post-surgery, the three-point bending test revealed that the structural stiffness of the groups CG and BG was higher than the values of the groups BG60 and BG120. Morphometric analysis revealed no differences between the control group and the Biosilcate group. Interestingly, the groups treated with Biosilicate and laser (BG 60 and BG120) showed statistically significant lower values of newly formed bone in the area of the defect when compared to negative control (CG) and bone defect group filled with Biosilicate (CB). Our findings suggest that although Biosilicate exerts some osteogenic activity during bone repair, laser therapy is not able to modulate this process.
Collapse
Affiliation(s)
- Poliani Oliveira
- Department of Physiotherapy, Federal University of São Carlos, São Carlos, SP, Brazil
| | | | | | | | | | | |
Collapse
|
95
|
Athanasiou VT, Papachristou DJ, Panagopoulos A, Saridis A, Scopa CD, Megas P. Histological comparison of autograft, allograft-DBM, xenograft, and synthetic grafts in a trabecular bone defect: an experimental study in rabbits. Med Sci Monit 2010; 16:BR24-BR31. [PMID: 20037482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023] Open
Abstract
BACKGROUND Different types of bone-graft substitutes have been developed and are on the market worldwide to eliminate the drawbacks of autogenous grafting. This experimental animal study was undertaken to evaluate the different histological properties of various bone graft substitutes utilized in this hospital. MATERIAL/METHODS Ninety New Zealand white rabbits were divided into six groups of 15 animals. Under general anesthesia, a 4.5 mm-wide hole was drilled into both the lateral femoral condyles of each rabbit, for a total of 180 condyles for analysis. The bone defects were filled with various grafts, these being 1) autograft, 2) DBM crunch allograft (Grafton), 3) bovine cancellous bone xenograft (Lubboc), 4) calcium phosphate hydroxyapatite substitute (Ceraform), 5) calcium sulfate substitute (Osteoset), and 6) no filling (control). The animals were sacrificed at 1, 3, and 6 months after implantation and tissue samples from the implanted areas were processed for histological evaluation. A histological grading scale was designed to determine the different histological parameters of bone healing. RESULTS The highest histological grades were achieved with the use of cancellous bone autograft. Bovine xenograft (Lubboc) was the second best in the histological scale grading. The other substitutes (Grafton, Ceraform, Osteoset) had similar scores but were inferior to both allograft and xenograft. CONCLUSIONS Bovine xenograft showed better biological response than the other bone graft substitutes; however, more clinical studies are necessary to determine its overall effectiveness.
Collapse
|
96
|
O'Donnell MD, Watts SJ, Hill RG, Law RV. The effect of phosphate content on the bioactivity of soda-lime-phosphosilicate glasses. J Mater Sci Mater Med 2009; 20:1611-1618. [PMID: 19330429 DOI: 10.1007/s10856-009-3732-2] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2008] [Accepted: 03/05/2009] [Indexed: 05/27/2023]
Abstract
We report on the bioactivity of two series of glasses in the SiO(2)-Na(2)O-CaO-P(2)O(5) system after immersion in simulated body fluid (SBF) after 21 days. The effect of P(2)O(5) content was examined for compositions containing 0-9.25 mol.% phosphate. Both series of glasses degraded to basic pH, but the solutions tended towards to neutrality with increasing phosphate content; a result of the acidic phosphate buffering the effect of the alkali metal and alkaline earth ions on degradation. Bioactivity was assessed by the appearance of features in the X-ray diffraction (XRD) traces and Fourier transform infrared (FTIR) spectra consistent with crystalline hydroxyl-carbonate-apatite (HCAp): such as the appearance of the (002) Bragg reflection in XRD and splitting of the P-O stretching vibration around 550 cm(-1) in the FTIR respectively. All glasses formed HCAp in SBF over the time periods studied and the time for formation of this crystalline phase occurred more rapidly in both series as the phosphate contents were increased. For P(2)O(5) content >3 mol.% both series exhibited highly crystalline apatite by 16 h immersion in SBF. This indicates that in the compositions studied, phosphate content is more important for bioactivity than network connectivity (NC) of the silicate phase and compositions showing rapid apatite formation are presented, superior to 45S5 Bioglass which was tested under identical conditions for comparison.
Collapse
Affiliation(s)
- M D O'Donnell
- Department of Materials, Imperial College London, London, UK.
| | | | | | | |
Collapse
|
97
|
Debusscher F, Aunoble S, Alsawad Y, Clement D, Le Huec JC. Anterior cervical fusion with a bio-resorbable composite cage (beta TCP-PLLA): clinical and radiological results from a prospective study on 20 patients. Eur Spine J 2009; 18:1314-20. [PMID: 19533180 DOI: 10.1007/s00586-009-1062-1] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2008] [Revised: 04/08/2009] [Accepted: 06/01/2009] [Indexed: 11/24/2022]
Abstract
A resorbable composite material (40% PLLA and 60% beta TCP) with a high breaking strength and capacity to withstand plastic and elastic strain has been developed for cervical interbody fusion. This is a prospective study to evaluate clinical and radiological results of 20 patients implanted with 27 cages (mean follow-up, 27 months). Clinical (neck disability index, VAS, neurological evaluation) and radiological (anteroposterior, lateral, bending X-rays) data were assessed before and after surgery. At the end of the study, CT scan was performed to evaluate fusion, resorption of the cage and density of the new tissue substituting the cage. The mean patient age was 50.3 years (range, 18-79 years). The average improvement was 55% for neck pain, 83% for arm pain and 65% for NDI, with 85% good or excellent results at final outcomes. Radiologically, lordosis was significantly improved (mean gain of 5.4 degrees and 3.7 degrees for overall and segmental lordosis, respectively). This correction was conserved in 95% of cases. Fusion was obtained in 96% (CT evaluation). Resorption was started in all cases and completed in an average of 36 months after surgery. The mean density of tissue substituting the cage was 659 UH with a range, of 455-911 UH (compatible with bone nature). Over time, the amount of bony tissue increased and the graft remodelled with an increase in density value. This demonstrates a biological activity and changing bone mineral content of this tissue. The new composite cage under investigation provides long-term fusion without loss of correction or inflammatory reaction. The ceramic block guarantees the maintenance of the disc height and its slow resorption allows long-term fusion and stability with good and reliable clinical and radiological outcomes.
Collapse
Affiliation(s)
- F Debusscher
- Spine Unit 2, CHU Pellegrin, Bordeaux 2 University, Amelie-Raba Leon State, 33000, Bordeaux, France
| | | | | | | | | |
Collapse
|
98
|
Walsh WR, Vizesi F, Cornwall GB, Bell D, Oliver R, Yu Y. Posterolateral spinal fusion in a rabbit model using a collagen-mineral composite bone graft substitute. Eur Spine J 2009; 18:1610-20. [PMID: 19475437 DOI: 10.1007/s00586-009-1034-5] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2009] [Revised: 04/03/2009] [Accepted: 05/10/2009] [Indexed: 11/26/2022]
Abstract
Choosing the appropriate graft material to participate in the healing process in posterolateral spinal fusion continues to be a challenge. Combining synthetic graft materials with bone marrow aspirate (BMA) and autograft is a reasonable treatment option for surgeons to potentially reduce or replace the need for autograft. FormaGraft, a bone graft material comprising 12% bovine-derived collagen and 88% ceramic in the form of hydroxyapatite (HAp) and beta tricalcium phosphate (beta-TCP) was evaluated in three possible treatment modalities for posterior spinal fusion in a standard rabbit model. These three treatment groups were FormaGraft alone, FormaGraft soaked in autogenous BMA, and FormaGraft with BMA and iliac crest autograft. No statistically demonstrable benefits or adverse effects of the addition of BMA were found in the current study based on macroscopic, radiology or mechanical data. This may reflect, in part, the good to excellent results of the collagen HA/TCP composite material alone in a well healing bony bed. Histology did, however, reveal a benefit with the use of BMA. Combining FormaGraft with autograft and BMA achieved results equivalent to autograft alone. The mineral and organic nature of the material provided a material that facilitated fusion between the transverse processes in a standard preclinical posterolateral fusion model.
Collapse
Affiliation(s)
- William Robert Walsh
- Surgical and Orthopaedic Research Laboratories (SORL), Prince of Wales Hospital, University of New South Wales, Level 1 Clinical Sciences Bldg, Sydney, NSW 2031, Australia.
| | | | | | | | | | | |
Collapse
|
99
|
Leu A, Stieger SM, Dayton P, Ferrara KW, Leach JK. Angiogenic response to bioactive glass promotes bone healing in an irradiated calvarial defect. Tissue Eng Part A 2009; 15:877-85. [PMID: 18795867 PMCID: PMC2992393 DOI: 10.1089/ten.tea.2008.0018] [Citation(s) in RCA: 103] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2008] [Accepted: 06/17/2008] [Indexed: 11/12/2022] Open
Abstract
Localized radiation is an effective treatment modality for carcinomas, yet the associated reduction of the host vasculature significantly inhibits the tissue's regenerative capacity. Low concentrations of bioactive glass (BG) possess angiogenic potential, and we hypothesized that localized BG presentation would increase neovascularization and promote healing in an irradiated bone defect. An isolated calvarial region of Sprague-Dawley rats was irradiated 2 weeks before surgery. Bilateral critical-sized defects were created and immediately filled with a BG-loaded collagen sponge or an empty sponge as an internal control. Histological analysis of calvaria collected after 2 weeks demonstrated greater neovascularization within the defect in the presence of BG than with collagen alone. Noninvasive ultrasound imaging at 4 weeks detected less contrast agent in the brain below BG-treated defects than in the nearby untreated defects and images of treated defects acquired at 2 weeks. The reduced ability to detect contrast agent in BG-treated defects suggested greater attenuation of ultrasound signal due to early bone formation. Micro-computed tomography imaging at 12 weeks demonstrated significantly greater bone volume fraction within BG-treated defects than in controls. These results suggest that neovascularization induced by localized BG delivery promotes bone regeneration in this highly compromised model of bone healing and may offer an alternative approach to costly growth factors and their potential side-effects.
Collapse
Affiliation(s)
- Ann Leu
- Department of Biomedical Engineering, University of California at Davis, Davis, California
| | - Susanne M. Stieger
- Department of Biomedical Engineering, University of California at Davis, Davis, California
- School of Veterinary Medicine, University of California at Davis, Davis, California
| | - Paul Dayton
- Department of Biomedical Engineering, University of California at Davis, Davis, California
| | - Katherine W. Ferrara
- Department of Biomedical Engineering, University of California at Davis, Davis, California
| | - J. Kent Leach
- Department of Biomedical Engineering, University of California at Davis, Davis, California
| |
Collapse
|
100
|
Miyazaki M, Tsumura H, Wang JC, Alanay A. An update on bone substitutes for spinal fusion. Eur Spine J 2009; 18:783-99. [PMID: 19280232 DOI: 10.1007/s00586-009-0924-x] [Citation(s) in RCA: 109] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2008] [Revised: 12/07/2008] [Accepted: 02/20/2009] [Indexed: 02/06/2023]
Abstract
With the current advances in spinal surgery, an understanding of the precise biological mechanism of each bone substitute is necessary for inducing successful spinal fusion. In this review, the categories of bone substitutes include allografts, ceramics, demineralized bone matrix, osteoinductive factors, autogenous platelet concentrate, mesenchymal stem cells, and gene therapy. Further, clinical studies have been evaluated by their levels of evidence in order to elucidate the precise effect of the bone substitute employed and to establish clinical guidance. This article will review both clinical studies based on evidence and basic research in current advances in order to avoid as far as possible any chances of failure in the future and to understand cellular biology in novel technologies.
Collapse
Affiliation(s)
- Masashi Miyazaki
- Department of Orthopaedic Surgery, Oita University, Oita, 879-5593, Japan
| | | | | | | |
Collapse
|