26
|
Suttle CM, Lawrenson JG, Conway ML. Efficacy of coloured overlays and lenses for treating reading difficulty: an overview of systematic reviews. Clin Exp Optom 2021; 101:514-520. [DOI: 10.1111/cxo.12676] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 01/30/2018] [Accepted: 02/11/2018] [Indexed: 01/08/2023] Open
|
27
|
Lawrenson JG, Dhakal R, Verkicharla PK, Shah R, Huntjens B, Downie LE, Kernohan A, Li T, Virgili G, Walline JJ. Interventions for myopia control in children: a living systematic review and network meta-analysis. Hippokratia 2021. [DOI: 10.1002/14651858.cd014758] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
28
|
Scheiman M, Kulp MT, Cotter SA, Lawrenson JG, Wang L, Li T. Interventions for convergence insufficiency: a network meta-analysis. Cochrane Database Syst Rev 2020; 12:CD006768. [PMID: 33263359 PMCID: PMC8092638 DOI: 10.1002/14651858.cd006768.pub3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Convergence insufficiency is a common binocular vision disorder in which the eyes have a strong tendency to drift outward (exophoria) with difficulty turning the eyes inward when reading or doing close work. OBJECTIVES To assess the comparative effectiveness and relative ranking of non-surgical interventions for convergence insufficiency through a systematic review and network meta-analysis (NMA). SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, PubMed and three trials registers up to 20 September 2019. SELECTION CRITERIA We included randomized controlled trials (RCTs) examining any form of non-surgical intervention versus placebo, no treatment, sham treatment, or other non-surgical interventions. Participants were children and adults with symptomatic convergence insufficiency. DATA COLLECTION AND ANALYSIS We followed standard Cochrane methodology. We performed NMAs separately for children and adults. MAIN RESULTS We included 12 trials (six in children and six in adults) with a total of 1289 participants. Trials evaluated seven interventions: 1) office-based vergence/accommodative therapy with home reinforcement; 2) home-based pencil/target push-ups; 3) home-based computer vergence/accommodative therapy; 4) office-based vergence/accommodative therapy alone; 5) placebo vergence/accommodative therapy or other placebo intervention; 6) prism reading glasses; and 7) placebo reading glasses. Six RCTs in the pediatric population randomized 968 participants. Of these, the Convergence Insufficiency Treatment Trial (CITT) Investigator Group completed four RCTs with 737 participants. All four CITT RCTs were rated at low risk of bias. Diagnostic criteria and outcome measures were identical or similar among these trials. The four CITT RCTs contributed data to the pediatric NMA, incorporating interventions 1, 2, 3 and 5. When treatment success was defined by a composite outcome requiring both clinical measures of convergence to be normal, and also show a pre-specified magnitude of improvement, we found high-certainty evidence that office-based vergence/accommodative therapy with home reinforcement increases the chance of a successful outcome, compared with home-based computer vergence/accommodative therapy (risk ratio (RR) 1.96, 95% confidence interval (CI) 1.32 to 2.94), home-based pencil/target push-ups (RR 2.86, 95% CI 1.82 to 4.35); and placebo (RR 3.04, 95% CI 2.32 to 3.98). However, there may be no evidence of any treatment difference between home-based computer vergence/accommodative therapy and home-based pencil/target push-ups (RR 1.44, 95% CI 0.93 to 2.24; low-certainty evidence), or between either of the two home-based therapies and placebo therapy, for the outcome of treatment success. When treatment success was defined as the composite convergence and symptom success outcome, we found moderate-certainty evidence that participants who received office-based vergence/accommodative therapy with home reinforcement were 5.12 (95% CI 2.01 to 13.07) times more likely to achieve treatment success than those who received placebo therapy. We found low-certainty evidence that participants who received office-based vergence/accommodative therapy with home reinforcement might be 4.41 (95% CI 1.26 to 15.38) times more likely to achieve treatment success than those who received home-based pencil push-ups, and 4.65 (95% CI 1.23 to 17.54) times more likely than those who received home-based computer vergence/accommodative therapy. There was no evidence of any treatment difference between home-based pencil push-ups and home-based computer vergence/accommodative therapy, or between either of the two home-based therapies and placebo therapy. One RCT evaluated the effectiveness of base-in prism reading glasses in children. When base-in prism reading glasses were compared with placebo reading glasses, investigators found no evidence of a difference in the three outcome measures of near point convergence (NPC), positive fusional vergence (PFV), or symptom scores measured by the Convergence Insufficiency Symptom Survey (CISS). Six RCTs in the adult population randomized 321 participants. We rated only one RCT at low risk of bias. Because not all studies of adults included composite success data, we could not conduct NMAs for treatment success. We thus were limited to comparing the mean difference (MD) between interventions for improving NPC, PFV, and CISS scores individually using data from three RCTs (107 participants; interventions 1, 2, 4 and 5). Compared with placebo treatment, office-based vergence accommodative therapy was relatively more effective in improving PFV (MD 16.73, 95% CI 6.96 to 26.60), but there was no evidence of a difference for NPC or the CISS score. There was no evidence of difference for any other comparisons for any outcomes. One trial evaluated base-in prism glasses prescribed for near-work activities and found that the prism glasses group had fewer symptoms compared with the placebo glasses group at three months (MD -8.9, 95% CI -11.6 to -6.3). The trial found no evidence of a difference with this intervention in NPC or PFV. No adverse effects related to study treatments were reported for any of the included studies. Excellent adherence was reported for office-based vergence/accommodative therapy (96.6% or higher) in two trials. Reported adherence with home-based therapy was less consistent, with one study reporting decreasing adherence over time (weeks 7 to 12) and lower completion rates with home-based pencil/target push-ups. AUTHORS' CONCLUSIONS Current research suggests that office-based vergence/accommodative therapy with home reinforcement is more effective than home-based pencil/target push-ups or home-based computer vergence/accommodative therapy for children. In adults, evidence of the effectiveness of various non-surgical interventions is less clear.
Collapse
|
29
|
Perais J, Agarwal R, Hogg R, Lawrenson JG, Evans JR, Takwoingi Y, Lois N. Prognostic factors for the development and progression of proliferative diabetic retinopathy in people with diabetic retinopathy. Hippokratia 2020. [DOI: 10.1002/14651858.cd013775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
30
|
|
31
|
Jindal A, Ctori I, Virgili G, Lucenteforte E, Lawrenson JG. Non-contact tests for identifying people at risk of primary angle closure glaucoma. Cochrane Database Syst Rev 2020; 5:CD012947. [PMID: 32468576 PMCID: PMC7390269 DOI: 10.1002/14651858.cd012947.pub2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Primary angle closure glaucoma (PACG) accounts for 50% of glaucoma blindness worldwide. More than three-quarters of individuals with PACG reside in Asia. In these populations, PACG often develops insidiously leading to chronically raised intraocular pressure and optic nerve damage, which is often asymptomatic. Non-contact tests to identify people at risk of angle closure are relatively quick and can be carried out by appropriately trained healthcare professionals or technicians as a triage test. If the test is positive, the person will be referred for further specialist assessment. OBJECTIVES To determine the diagnostic accuracy of non-contact tests (limbal anterior chamber depth (LACD) (van Herick test); oblique flashlight test; scanning peripheral anterior chamber depth analyser (SPAC), Scheimpflug photography; anterior segment optical coherence tomography (AS-OCT), for identifying people with an occludable angle. SEARCH METHODS We searched the following bibliographic databases 3 October 2019: CENTRAL; MEDLINE; Embase; BIOSIS; OpenGrey; ARIF and clinical trials registries. The searches were limited to remove case reports. There were no date or language restrictions in the searches. SELECTION CRITERIA We included prospective and retrospective cross-sectional, cohort and case-control studies conducted in any setting that evaluated the accuracy of one or more index tests for identifying people with an occludable angle compared to a gonioscopic reference standard. DATA COLLECTION AND ANALYSIS Two review authors independently performed data extraction and quality assessment using QUADAS2 for each study. For each test, 2 x 2 tables were constructed and sensitivity and specificity were calculated. When four or more studies provided data at fixed thresholds for each test, we fitted a bivariate model using the METADAS macro in SAS to calculate pooled point estimates for sensitivity and specificity. For comparisons between index tests and subgroups, we performed a likelihood ratio test comparing the model with and without the covariate. MAIN RESULTS We included 47 studies involving 26,151 participants and analysing data from 23,440. Most studies were conducted in Asia (36, 76.6%). Twenty-seven studies assessed AS-OCT (analysing 15,580 participants), 17 studies LACD (7385 participants), nine studies Scheimpflug photography (1616 participants), six studies SPAC (5239 participants) and five studies evaluated the oblique flashlight test (998 participants). Regarding study quality, 36 of the included studies (76.6%) were judged to have a high risk of bias in at least one domain.The use of a case-control design (13 studies) or inappropriate exclusions (6 studies) raised patient selection concerns in 40.4% of studies and concerns in the index test domain in 59.6% of studies were due to lack of masking or post-hoc determination of optimal thresholds. Among studies that did not use a case-control design, 16 studies (20,599 participants) were conducted in a primary care/community setting and 18 studies (2590 participants) in secondary care settings, of which 15 investigated LACD. Summary estimates were calculated for commonly reported parameters and thresholds for each test; LACD ≤ 25% (16 studies, 7540 eyes): sensitivity 0.83 (95% confidence interval (CI) 0.74, 0.90), specificity 0.88 (95% CI 0.84, 0.92) (moderate-certainty); flashlight (grade1) (5 studies, 1188 eyes): sensitivity 0.51 (95% CI 0.25, 0.76), specificity 0.92 (95% CI 0.70, 0.98) (low-certainty); SPAC (≤ 5 and/or S or P) (4 studies, 4677 eyes): sensitivity 0.83 (95% CI 0.70, 0.91), specificity 0.78 (95% CI 0.70, 0.83) (moderate-certainty); Scheimpflug photography (central ACD) (9 studies, 1698 eyes): sensitivity 0.92 (95% CI 0.84, 0.96), specificity 0.86 (95% CI 0.76, 0.93) (moderate-certainty); AS-OCT (subjective opinion of occludability) (13 studies, 9242 eyes): sensitivity 0.85 (95% CI 0.76, 0.91); specificity 0.71 (95% CI 0.62, 0.78) (moderate-certainty). For comparisons of sensitivity and specificity between index tests we used LACD (≤ 25%) as the reference category. The flashlight test (grade 1 threshold) showed a statistically significant lower sensitivity than LACD (≤ 25%), whereas AS-OCT (subjective judgement) had a statistically significant lower specificity. There were no statistically significant differences for the other index test comparisons. A subgroup analysis was conducted for LACD (≤ 25%), comparing community (7 studies, 14.4% prevalence) vs secondary care (7 studies, 42% prevalence) settings. We found no evidence of a statistically significant difference in test performance according to setting. Performing LACD on 1000 people at risk of angle closure with a prevalence of occludable angles of 10%, LACD would miss about 17 cases out of the 100 with occludable angles and incorrectly classify 108 out of 900 without angle closure. AUTHORS' CONCLUSIONS The finding that LACD performed as well as index tests that use sophisticated imaging technologies, confirms the potential for this test for case-detection of occludable angles in high-risk populations. However, methodological issues across studies may have led to our estimates of test accuracy being higher than would be expected in standard clinical practice. There is still a need for high-quality studies to evaluate the performance of non-invasive tests for angle assessment in both community-based and secondary care settings.
Collapse
|
32
|
McGarva E, Farr J, Dabasia P, Lawrenson JG, Murdoch IE. Initial experience in self-monitoring of intraocular pressure. Eur J Ophthalmol 2020; 31:1326-1332. [PMID: 32340488 PMCID: PMC8358569 DOI: 10.1177/1120672120920217] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background/aims Diurnal variation in intraocular pressure (IOP) is a routine assessment in glaucoma management. Providing patients the opportunity to perform self-tonometry might empower them and free hospital resource. We previously demonstrated that 74% of patients can use the Icare® HOME tonometer. This study further explores Icare® HOME patient self-monitoring. Methods Patients were trained by standard protocol to use the Icare® HOME rebound tonometer. Patient self-tonometry was compared to Goldmann applanation tonometry (GAT) over one clinical day. Following this, each patient was instructed to undertake further data collection that evening and over the subsequent two days. Results Eighteen patients (35 eyes) participated. Good agreement was demonstrated between GAT and Icare® HOME for IOPs up to 15 mm Hg. Above this IOP the Icare® tended to over-read, largely explained by 2 patients with corneal thickness >600 um. The mean peak IOP during ‘clinic hours’ phasing was 16.7 mm Hg and 18.5 mm Hg (p = 0.24) over three days. An average range of 5.0, 7.0 and 9.8 mm Hg was shown during single day clinic, single day home and three day home phasing respectively (p =<0.001). The range of IOP was lower in eyes with prior trabeculectomy (6.1 mm Hg vs 12.2 mm Hg). All patients undertook one reading in the early morning at home with an average of 4.8 readings during, and 3.1 readings after office hours. Conclusions This small study shows that self-tonometry is feasible. The findings from home phasing demonstrated higher peak and trough IOPs, providing additional clinical information. Home phasing is a viable alternative. The cost-effectiveness of this approach has yet to be addressed.
Collapse
|
33
|
Lorencatto F, Asif S, Francis JJ, Harper AM, Lawrenson JG. Seeing New Opportunities to Help Smokers Quit: A UK National Survey of Optometrist-Delivered Smoking Cessation Behavioral Support Interventions. Nicotine Tob Res 2020; 21:655-662. [PMID: 29660046 DOI: 10.1093/ntr/nty066] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 04/04/2018] [Indexed: 11/14/2022]
Abstract
BACKGROUND Smoking is a risk factor for various eye conditions. Brief smoking cessation interventions have demonstrated effectiveness when delivered by a range of health care professionals. Optometrists are well placed in the community to advise otherwise healthy smokers to quit, yet remain relatively neglected in smoking cessation research and policy. In a national survey, this study investigated self-reported practices of UK optometrists for delivering brief tobacco smoking cessation interventions to patients. METHODS A randomly selected sample of 1200 optometrists out of the 9000 optometrists registered on the UK College of Optometrists database were invited to complete a 40-item, web-based survey assessing: training related to smoking cessation, current practice (ie, the proportion of patients to which components of very brief advice [Ask, Advise, Assist] and other evidence-based smoking cessation behavior change techniques were delivered), and barriers/enablers to intervention delivery. RESULTS In total, 408 (34%) responses were received. Most (83%) optometrists received no training in practical skills for delivering smoking cessation support. A third (34%) routinely assessed smoking status. Fewer self-reported advising smokers to quit (22%), offering assistance (via referral to dedicated services) (3%), or advice on smoking cessation medications (2%). Perceived barriers included insufficient knowledge/training (81%) and time (65%). Optometrists were more likely to assess and advise on smoking cessation if they practiced in Scotland, χ2(2) = 32.95, p < .001; an independent optometry practice, χ2(1) = 4.27, p = .39; or had received smoking cessation training, χ2(1) = 13.1, p < .001. CONCLUSIONS Substantial gaps exist in UK optometrists' current smoking cessation training and practice. Evidence-based training resources are needed to support the implementation of smoking cessation interventions into routine optometry practice. IMPLICATIONS Optometrists are well placed in the community to deliver brief advice interventions to a large population of smokers. This survey provides a comprehensive description of current UK optometry practice related to the provision of evidence-based brief tobacco smoking cessation interventions to patients. Although optometrists perceive advising on smoking cessation as part of their role, numerous substantial gaps in current practice and training remain, which need to be addressed through targeted interventions to increase implementation.
Collapse
|
34
|
Downie LE, Wormald R, Evans J, Virgili G, Keller PR, Lawrenson JG, Li T. Analysis of a Systematic Review About Blue Light-Filtering Intraocular Lenses for Retinal Protection: Understanding the Limitations of the Evidence. JAMA Ophthalmol 2020; 137:694-697. [PMID: 30789642 DOI: 10.1001/jamaophthalmol.2019.0019] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Importance Cataract surgery, with intraocular lens (IOL) implantation, is the most common ocular surgical procedure worldwide. It has been suggested that IOLs that selectively attenuate short wavelength visible light (blue light-filtering IOLs) may be beneficial for macular health. Whether blue light-filtering IOLs impart retinal photoprotection is of public health relevance, particularly in the context of aging demographics and the increasing global prevalence of age-related macular degeneration. This review analyzes and interprets the key findings, including consideration of the implications for practice and future research, of a 2018 Cochrane systematic review that evaluated the efficacy and safety of blue light-filtering IOLs for providing protection to macular health and function. Observations The Cochrane systematic review included 51 randomized controlled trials that were performed in 17 countries. The trials involved adults undergoing cataract surgery in which a blue light-filtering IOL was compared with an equivalent non-blue light-filtering IOL. Study follow-up periods ranged from 1 month to 5 years. Together, these studies considered clinical outcomes in more than 5000 eyes. There was limited ability to combine data across trials (to draw overall conclusions) because of the use of different measurement techniques for outcomes, incomplete reporting of data, and/or varied follow-up periods. We identified substantial shortcomings in the internal validity of many of the included studies, particularly regarding trial design, conduct, and reporting. We propose several avenues for improving the rigor of potential future research in the field, including developing a core set of outcome measures, the inclusion of sample size calculations, the masking of trial participants and outcome assessors, and prospective clinical trial registration. Conclusions and Relevance Using blue light-filtering IOLs to impart benefits to the macula is currently not supported by the best available clinical research evidence, and it is important that clinicians are mindful of this evidence limitation when adopting these devices in clinical practice.
Collapse
|
35
|
Fidalgo BR, Dabasia P, Jindal A, Edgar DF, Ctori I, Peto T, Lawrenson JG. Role of advanced technology in the detection of sight-threatening eye disease in a UK community setting. BMJ Open Ophthalmol 2020; 4:e000347. [PMID: 31909190 PMCID: PMC6936448 DOI: 10.1136/bmjophth-2019-000347] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 09/23/2019] [Accepted: 10/31/2019] [Indexed: 11/05/2022] Open
Abstract
Background/aims To determine the performance of combinations of structural and functional screening tests in detecting sight-threatening eye disease in a cohort of elderly subjects recruited from primary care. Methods 505 subjects aged ≥60 years underwent frequency doubling technology (FDT) perimetry, iVue optical coherence tomography (iWellness and peripapillary retinal nerve fibre layer (RNFL) scans) and intraocular pressure with the Ocular Response Analyzer, all performed by an ophthalmic technician. The reference standard was a full ophthalmic examination by an experienced clinician who was masked to the index test results. Subjects were classified as presence or absence of sight-threatening eye disease (clinically significant cataract, primary open-angle glaucoma, intermediate or advanced age-related macular degeneration and significant diabetic retinopathy). Univariate and multivariate logistic regression analyses were used to determine the association between abnormal screening test results and the presence of sight-threatening eye disease. Results 171 subjects (33.8%) had one or more sight-threatening eye diseases. The multivariate analysis found significant associations with any of the target conditions for visual acuity of <6/12, an abnormal FDT and peripapillary RNFL thickness outside the 99% normal limit. The sensitivity of this optimised screening panel was 61.3% (95% CI 53.5 to 68.7), with a specificity of 78.8% (95% CI 74.0 to 83.1), a positive predictive value of 59.5% (95% CI 53.7 to 65.2) and an overall diagnostic accuracy of 72.9% (95% CI 68.8 to 76.8). Conclusions A subset of screening tests may provide an accurate and efficient means of population screening for significant eye disease in the elderly. This study provides useful preliminary data to inform the development of further larger, multicentre screening studies to validate this screening panel.
Collapse
|
36
|
Jindal A, Ctori I, Fidalgo B, Dabasia P, Balaskas K, Lawrenson JG. Impact of optical coherence tomography on diagnostic decision-making by UK community optometrists: a clinical vignette study. Ophthalmic Physiol Opt 2019; 39:205-215. [PMID: 30994199 PMCID: PMC6849707 DOI: 10.1111/opo.12613] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Accepted: 03/13/2019] [Indexed: 11/30/2022]
Abstract
Purpose In recent years, there has been widespread investment in imaging technologies by community optometrists in the UK, most notably optical coherence tomography (OCT). The aim of the current study was to determine the value of OCT in the diagnosis of posterior segment diseases in a representative sample of community optometrists using a clinical vignette methodology. Methods A group of community optometrists (n = 50) initially completed a standardised training package on OCT interpretation followed by a computer‐based assessment featuring 52 clinical vignettes, containing images of healthy (n = 8) or glaucomatous (n = 18) discs or healthy (n = 8) or diseased (n = 18) fundi. Each vignette featured either a single fundus/disc photographic image, or a combination of a fundus/disc image with the corresponding OCT scan. An expert panel confirmed that the fundus images presented alone and those in combination with OCT data were of a similar level of difficulty and that the cases were typical of those seen in primary care. For each case, the optometrist selected their diagnosis from a pull‐down list and reported their confidence in their decision using a 10‐point Likert scale. Pairwise comparisons of the fundus image alone and fundus image/OCT combination were made for both diagnostic performance and confidence. Results The mean percentage of correct diagnoses using fundus imaging alone was 62% (95% CI 59–64%) and for the combination of fundus image/OCT was 80% (95% CI 77–82%). The mean false negative rate with fundus alone was 27% reducing to 13% with the OCT combination. Median confidence scores for fundus imaging alone was 8.0 (IQR 7.0–8.0) and 8.3 (IQR 8.0–9.0) for the combination. Improvements in performance and confidence were statistically significant (p < 0.001). Conclusion The results from this vignette study suggests that OCT improves optometrists’ diagnostic performance compared to fundus observation alone. These initial results suggest that OCT provides valuable additional data that could augment case‐finding for glaucoma and retinal disease; however, further research is needed to assess its diagnostic performance in a routine clinical practice setting.
Collapse
|
37
|
Lawrenson JG, Graham-Rowe E, Lorencatto F, Rice S, Bunce C, Francis JJ, Burr JM, Aluko P, Vale L, Peto T, Presseau J, Ivers NM, Grimshaw JM. What works to increase attendance for diabetic retinopathy screening? An evidence synthesis and economic analysis. Health Technol Assess 2019; 22:1-160. [PMID: 29855423 DOI: 10.3310/hta22290] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Diabetic retinopathy screening (DRS) is effective but uptake is suboptimal. OBJECTIVES To determine the effectiveness of quality improvement (QI) interventions for DRS attendance; describe the interventions in terms of QI components and behaviour change techniques (BCTs); identify theoretical determinants of attendance; investigate coherence between BCTs identified in interventions and determinants of attendance; and determine the cost-effectiveness of QI components and BCTs for improving DRS. DATA SOURCES AND REVIEW METHODS Phase 1 - systematic review of randomised controlled trials (RCTs) evaluating interventions to increase DRS attendance (The Cochrane Library, MEDLINE, EMBASE and trials registers to February 2017) and coding intervention content to classify QI components and BCTs. Phase 2 - review of studies reporting factors influencing attendance, coded to theoretical domains (MEDLINE, EMBASE, PsycINFO and sources of grey literature to March 2016). Phase 3 - mapping BCTs (phase 1) to theoretical domains (phase 2) and an economic evaluation to determine the cost-effectiveness of BCTs or QI components. RESULTS Phase 1 - 7277 studies were screened, of which 66 RCTs were included in the review. Interventions were multifaceted and targeted patients, health-care professionals (HCPs) or health-care systems. Overall, interventions increased DRS attendance by 12% [risk difference (RD) 0.12, 95% confidence interval (CI) 0.10 to 0.14] compared with usual care, with substantial heterogeneity in effect size. Both DRS-targeted and general QI interventions were effective, particularly when baseline attendance levels were low. All commonly used QI components and BCTs were associated with significant improvements, particularly in those with poor attendance. Higher effect estimates were observed in subgroup analyses for the BCTs of 'goal setting (outcome, i.e. consequences)' (RD 0.26, 95% CI 0.16 to 0.36) and 'feedback on outcomes (consequences) of behaviour' (RD 0.22, 95% CI 0.15 to 0.29) in interventions targeting patients and of 'restructuring the social environment' (RD 0.19, 95% CI 0.12 to 0.26) and 'credible source' (RD 0.16, 95% CI 0.08 to 0.24) in interventions targeting HCPs. Phase 2 - 3457 studies were screened, of which 65 non-randomised studies were included in the review. The following theoretical domains were likely to influence attendance: 'environmental context and resources', 'social influences', 'knowledge', 'memory, attention and decision processes', 'beliefs about consequences' and 'emotions'. Phase 3 - mapping identified that interventions included BCTs targeting important barriers to/enablers of DRS attendance. However, BCTs targeting emotional factors around DRS were under-represented. QI components were unlikely to be cost-effective whereas BCTs with a high probability (≥ 0.975) of being cost-effective at a societal willingness-to-pay threshold of £20,000 per QALY included 'goal-setting (outcome)', 'feedback on outcomes of behaviour', 'social support' and 'information about health consequences'. Cost-effectiveness increased when DRS attendance was lower and with longer screening intervals. LIMITATIONS Quality improvement/BCT coding was dependent on descriptions of intervention content in primary sources; methods for the identification of coherence of BCTs require improvement. CONCLUSIONS Randomised controlled trial evidence indicates that QI interventions incorporating specific BCT components are associated with meaningful improvements in DRS attendance compared with usual care. Interventions generally used appropriate BCTs that target important barriers to screening attendance, with a high probability of being cost-effective. Research is needed to optimise BCTs or BCT combinations that seek to improve DRS attendance at an acceptable cost. BCTs targeting emotional factors represent a missed opportunity to improve attendance and should be tested in future studies. STUDY REGISTRATION This study is registered as PROSPERO CRD42016044157 and PROSPERO CRD42016032990. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
|
38
|
Downie LE, Keller PR, Busija L, Lawrenson JG, Hull CC. Blue-light filtering spectacle lenses for visual performance, sleep, and macular health in adults. Hippokratia 2019. [DOI: 10.1002/14651858.cd013244] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
39
|
Fidalgo BR, Jindal A, Tyler CW, Ctori I, Lawrenson JG. Development and validation of a new glaucoma screening test using temporally modulated flicker. Ophthalmic Physiol Opt 2018; 38:617-628. [PMID: 30575071 DOI: 10.1111/opo.12588] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Accepted: 11/01/2018] [Indexed: 11/30/2022]
Abstract
PURPOSE Describing the psychometric characteristics and diagnostic accuracy of the Accelerator 4-Alternative Forced-Choice Flicker Test prototype (A4FTp) for detecting chronic open angle glaucoma (COAG). METHODS A4FTp measures temporally-modulated flicker thresholds in regions of the visual field with high susceptibility to glaucomatous loss. We initially evaluated its psychometric properties on 20 normals (aged 33.8 ± 8.5 years) who were tested multiple times over a period of 3 months. All subjects underwent four repetitions for shorter (T8) and longer (T12) staircase termination criteria, to determine the most suitable threshold criterion. Four randomly selected subjects underwent a total of 10 repetitions to study test-retest repeatability and learning effects. To determine its diagnostic accuracy, one eye of 40 participants with COAG and 38 normal controls were tested with the A4FTp in comparison with the Frequency Doubling Technology (FDT; C20-5 programme) and iVue Spectral Domain Optical Coherence Tomography (SD-OCT). Tests were conducted in a random order with results masked to the clinician conducting the reference ophthalmic examination. The accuracy of each test was determined by analysis of the area under the receiver operator characteristic curve (AUROC). RESULTS A4FTp flicker thresholds were stable, with standard deviations of only 0.52 decilog (dL) for T8, increasing to 1.32 dL for T12, and no significant flicker sensitivity threshold improvement over the 10 repeat runs. T8 was superior to T12 on several other measures, so it was used for the remaining comparisons. In terms of diagnostic accuracy, the mean AUROC for the three tests were A4FTp [T8 criterion; 0.82, 95% confidence interval (0.73-0.92)]; SD-OCT [any RNFL parameter p < 1% level; 0.90 (0.83-0.97)]; and FDT [one or more locations missed at p < 5% level; 0.91 (0.82-0.96)]. There was no statistical difference in AUROC between A4FTp and SD-OCT (p = 0.18) or FDT (p = 0.12). The A4FTp test duration averaged just over 2 min per eye, taking approximately one-third of the time for completion of the HFA SITA 24-2 algorithm (conducted as part of the reference examination) and twice the time for the suprathreshold FDT. CONCLUSION Test accuracy for the A4FTp was comparable to those of the FDT and SD-OCT for the detection of COAG. Time taken to complete the A4FTp was relatively short and initial results are promising. With further refinement, the A4FTp could have a future role in glaucoma detection.
Collapse
|
40
|
Harper RA, Lawrenson JG. Rapid expansion of optometry student numbers in the UK: potential for significant risk. Ophthalmic Physiol Opt 2018; 38:471-473. [PMID: 30357901 DOI: 10.1111/opo.12585] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
41
|
Gunn PJG, Marks JR, Konstantakopoulou E, Edgar DF, Lawrenson JG, Roberts SA, Spencer AF, Fenerty CH, Harper RA. Clinical effectiveness of the Manchester Glaucoma Enhanced Referral Scheme. Br J Ophthalmol 2018; 103:1066-1071. [PMID: 30309913 PMCID: PMC6678050 DOI: 10.1136/bjophthalmol-2018-312385] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Revised: 07/24/2018] [Accepted: 08/18/2018] [Indexed: 11/26/2022]
Abstract
Background Glaucoma referral filtering schemes have operated in the UK for many years. However, there is a paucity of data on the false-negative (FN) rate. This study evaluated the clinical effectiveness of the Manchester Glaucoma Enhanced Referral Scheme (GERS), estimating both the false-positive (FP) and FN rates. Method Outcome data were collected for patients newly referred through GERS and assessed in ‘usual-care’ clinics to determine the FP rate (referred patients subsequently discharged at their first visit). For the FN rate, glaucoma suspects deemed not requiring referral following GERS assessment were invited to attend for a ‘reference standard’ examination including all elements of assessment recommended by National Institute for Health and Care Excellence (NICE) by a glaucoma specialist optometrist. A separate 33 cases comprising randomly selected referred and non-referred cases were reviewed independently by two glaucoma specialist consultant ophthalmologists to validate the reference standard assessment. Results 1404 patients were evaluated in GERS during the study period; 651 (46.3%) were referred to the Hospital Eye Service (HES) and 753 (53.6%) were discharged. The FP rate in 307 assessable patients referred to the HES was 15.5%. This study reviewed 131 (17.4%) of those patients not referred to the HES through the GERS scheme; 117 (89.3%) were confirmed as not requiring hospital follow-up; 14 (10.7%) required follow-up, including 5 (3.8%) offered treatment. Only one patient (0.8%) in this sample met the GERS referral criteria and was not referred (true FN). There were no cases of missed glaucoma or non-glaucomatous pathology identified within our sample. Conclusion The Manchester GERS is an effective glaucoma filtering scheme with a low FP and FN rate.
Collapse
|
42
|
Graham-Rowe E, Lorencatto F, Lawrenson JG, Burr JM, Grimshaw JM, Ivers NM, Presseau J, Vale L, Peto T, Bunce C, J Francis J. Barriers to and enablers of diabetic retinopathy screening attendance: a systematic review of published and grey literature. Diabet Med 2018; 35:1308-1319. [PMID: 29790594 DOI: 10.1111/dme.13686] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/18/2018] [Indexed: 11/29/2022]
Abstract
AIMS To identify and synthesize studies reporting modifiable barriers/enablers associated with retinopathy screening attendance in people with Type 1 or Type 2 diabetes, and to identify those most likely to influence attendance. METHODS We searched MEDLINE, EMBASE, PsycINFO, Cochrane Library and the 'grey literature' for quantitative and qualitative studies to February 2017. Data (i.e. participant quotations, interpretive summaries, survey results) reporting barriers/enablers were extracted and deductively coded into domains from the Theoretical Domains Framework; with domains representing categories of theoretical barriers/enablers proposed to mediate behaviour change. Inductive thematic analysis was conducted within domains to describe the role each domain plays in facilitating or hindering screening attendance. Domains that were more frequently coded and for which more themes were generated were judged more likely to influence attendance. RESULTS Sixty-nine primary studies were included. We identified six theoretical domains ['environmental context and resources' (75% of included studies), 'social influences' (51%), 'knowledge' (51%), 'memory, attention, decision processes' (50%), 'beliefs about consequences' (38%) and 'emotions' (33%)] as the key mediators of diabetic retinopathy screening attendance. Examples of barriers populating these domains included inaccurate diabetic registers and confusion between routine eye care and retinopathy screening. Recommendations by healthcare professionals and community-level media coverage acted as enablers. CONCLUSIONS Across a variety of contexts, we found common barriers to and enablers of retinopathy screening that could be targeted in interventions aiming to increase screening attendance.
Collapse
|
43
|
Sheeladevi S, Lawrenson JG, Fielder A, Kekunnaya R, Ali R, Borah RR, Suttle C. Delay in presentation to hospital for childhood cataract surgery in India. Eye (Lond) 2018; 32:1811-1818. [PMID: 30061651 PMCID: PMC6292888 DOI: 10.1038/s41433-018-0176-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Revised: 04/03/2018] [Accepted: 05/30/2018] [Indexed: 11/10/2022] Open
Abstract
Purpose Cataract is one of the major causes of avoidable visual disability in children and the aim of this study was to investigate the age at which children with cataract present for surgery at tertiary hospitals across India. Methods A prospective multicenter study collected data from 9 eye hospitals in 8 states in India. All children admitted for cataract surgery between Nov 2015 and March 2016 were considered eligible. Parents were interviewed at the hospital by trained personnel and socio demographic information, age at diagnosis and at surgery and the relevant clinical data were obtained from the medical records. Mean age, age range at surgery were used and performed logistic regression analyses. Results Parents of 751 consecutive cases were interviewed, of which 469(63%) were boys and 548 (73%) were from rural areas. Cataract was bilateral in 493 (66%) and unilateral in 258 (34%); of the unilateral cases, 179 (69%) were due to trauma. The mean age at surgery for ‘congenital’ and ‘developmental’ cataract was 48.2 ± 50.9 and 99.7 ± 46.42 months, respectively and the mean age was lower in the southern region compared to other regions. Children with 2 or more siblings at home were five times more likely to undergo surgery within 12 months (OR, 4.69; 95% CI: 2.04–10.79; p = < 0.001). Conclusions Late surgery for childhood cataract remains a major challenge and the factors determining this issue in India are pertinent also to several other countries and need to be addressed for every child with cataract to achieve full visual potential.
Collapse
|
44
|
Konstantakopoulou E, Harper RA, Edgar DF, Larkin G, Janikoun S, Lawrenson JG. Clinical safety of a minor eye conditions scheme in England delivered by community optometrists. BMJ Open Ophthalmol 2018; 3:e000125. [PMID: 29657980 PMCID: PMC5895973 DOI: 10.1136/bmjophth-2017-000125] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Revised: 01/09/2018] [Accepted: 01/29/2018] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE The aim of this study was to monitor the activity and evaluate the clinical safety of a minor eye conditions scheme (MECS) conducted by accredited community optometrists in Lambeth and Lewisham, London. METHODS AND ANALYSIS Optometrists underwent an accredited training programme, including attendance at hospital eye services (HES) clinics. Patients who satisfied certain inclusion criteria were referred to accredited MECS optometrists by their general practitioners (GPs) or could self-refer. Data were extracted from clinical records. A sample of MECS clinical records was graded to assess the quality of the MECS optometrists' clinical management decisions. Referrals to the HES were assessed by the collaborating ophthalmologists and feedback was provided. RESULTS A total of 2123 patients (mean age 47 years) were seen over 12 months. Two-thirds of the patients (67.3%) were referred by their GP. The most common reasons for patients needing a MECS assessment were 'red eye' (36.7% of patients), 'painful white eye' (11.1%), 'flashes and floaters' (10.2%); 8.7% of patients had a follow-up appointment. Of the patients seen, 75.1% were retained in the community, 5.7% were referred to their GP and 18.9% were referred to the HES. Of the HES referrals, 49.1% were routine, 22.6% urgent and 28.3% emergency. Of the records reviewed, 94.5% were rated as appropriately managed; 89.2% of the HES referrals were considered appropriate. CONCLUSION The findings of this study indicate that optometrists are in a good position to work very safely within the remits of the scheme and to assess risk.
Collapse
|
45
|
Jindal A, Ctori I, Virgili G, Lucenteforte E, Lawrenson JG. Non-contact methods for the detection of people at risk of primary angle closure glaucoma. Hippokratia 2018. [DOI: 10.1002/14651858.cd012947] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
46
|
Lawrenson JG, Graham‐Rowe E, Lorencatto F, Burr J, Bunce C, Francis JJ, Aluko P, Rice S, Vale L, Peto T, Presseau J, Ivers N, Grimshaw JM. Interventions to increase attendance for diabetic retinopathy screening. Cochrane Database Syst Rev 2018; 1:CD012054. [PMID: 29333660 PMCID: PMC6491139 DOI: 10.1002/14651858.cd012054.pub2] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Despite evidence supporting the effectiveness of diabetic retinopathy screening (DRS) in reducing the risk of sight loss, attendance for screening is consistently below recommended levels. OBJECTIVES The primary objective of the review was to assess the effectiveness of quality improvement (QI) interventions that seek to increase attendance for DRS in people with type 1 and type 2 diabetes.Secondary objectives were:To use validated taxonomies of QI intervention strategies and behaviour change techniques (BCTs) to code the description of interventions in the included studies and determine whether interventions that include particular QI strategies or component BCTs are more effective in increasing screening attendance;To explore heterogeneity in effect size within and between studies to identify potential explanatory factors for variability in effect size;To explore differential effects in subgroups to provide information on how equity of screening attendance could be improved;To critically appraise and summarise current evidence on the resource use, costs and cost effectiveness. SEARCH METHODS We searched the Cochrane Library, MEDLINE, Embase, PsycINFO, Web of Science, ProQuest Family Health, OpenGrey, the ISRCTN, ClinicalTrials.gov, and the WHO ICTRP to identify randomised controlled trials (RCTs) that were designed to improve attendance for DRS or were evaluating general quality improvement (QI) strategies for diabetes care and reported the effect of the intervention on DRS attendance. We searched the resources on 13 February 2017. We did not use any date or language restrictions in the searches. SELECTION CRITERIA We included RCTs that compared any QI intervention to usual care or a more intensive (stepped) intervention versus a less intensive intervention. DATA COLLECTION AND ANALYSIS We coded the QI strategy using a modification of the taxonomy developed by Cochrane Effective Practice and Organisation of Care (EPOC) and BCTs using the BCT Taxonomy version 1 (BCTTv1). We used Place of residence, Race/ethnicity/culture/language, Occupation, Gender/sex, Religion, Education, Socioeconomic status, and Social capital (PROGRESS) elements to describe the characteristics of participants in the included studies that could have an impact on equity of access to health services.Two review authors independently extracted data. One review author entered the data into Review Manager 5 and a second review author checked them. Two review authors independently assessed risks of bias in the included studies and extracted data. We rated certainty of evidence using GRADE. MAIN RESULTS We included 66 RCTs conducted predominantly (62%) in the USA. Overall we judged the trials to be at low or unclear risk of bias. QI strategies were multifaceted and targeted patients, healthcare professionals or healthcare systems. Fifty-six studies (329,164 participants) compared intervention versus usual care (median duration of follow-up 12 months). Overall, DRS attendance increased by 12% (risk difference (RD) 0.12, 95% confidence interval (CI) 0.10 to 0.14; low-certainty evidence) compared with usual care, with substantial heterogeneity in effect size. Both DRS-targeted (RD 0.17, 95% CI 0.11 to 0.22) and general QI interventions (RD 0.12, 95% CI 0.09 to 0.15) were effective, particularly where baseline DRS attendance was low. All BCT combinations were associated with significant improvements, particularly in those with poor attendance. We found higher effect estimates in subgroup analyses for the BCTs 'goal setting (outcome)' (RD 0.26, 95% CI 0.16 to 0.36) and 'feedback on outcomes of behaviour' (RD 0.22, 95% CI 0.15 to 0.29) in interventions targeting patients, and 'restructuring the social environment' (RD 0.19, 95% CI 0.12 to 0.26) and 'credible source' (RD 0.16, 95% CI 0.08 to 0.24) in interventions targeting healthcare professionals.Ten studies (23,715 participants) compared a more intensive (stepped) intervention versus a less intensive intervention. In these studies DRS attendance increased by 5% (RD 0.05, 95% CI 0.02 to 0.09; moderate-certainty evidence).Fourteen studies reporting any QI intervention compared to usual care included economic outcomes. However, only five of these were full economic evaluations. Overall, we found that there is insufficient evidence to draw robust conclusions about the relative cost effectiveness of the interventions compared to each other or against usual care.With the exception of gender and ethnicity, the characteristics of participants were poorly described in terms of PROGRESS elements. Seventeen studies (25.8%) were conducted in disadvantaged populations. No studies were carried out in low- or middle-income countries. AUTHORS' CONCLUSIONS The results of this review provide evidence that QI interventions targeting patients, healthcare professionals or the healthcare system are associated with meaningful improvements in DRS attendance compared to usual care. There was no statistically significant difference between interventions specifically aimed at DRS and those which were part of a general QI strategy for improving diabetes care. This is a significant finding, due to the additional benefits of general QI interventions in terms of improving glycaemic control, vascular risk management and screening for other microvascular complications. It is likely that further (but smaller) improvements in DRS attendance can also be achieved by increasing the intensity of a particular QI component or adding further components.
Collapse
|
47
|
Lawrenson JG, Hull CC, Downie LE. The effect of blue-light blocking spectacle lenses on visual performance, macular health and the sleep-wake cycle: a systematic review of the literature. Ophthalmic Physiol Opt 2017; 37:644-654. [PMID: 29044670 DOI: 10.1111/opo.12406] [Citation(s) in RCA: 81] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Accepted: 08/17/2017] [Indexed: 12/19/2022]
Abstract
PURPOSE Blue-blocking (BB) spectacle lenses, which attenuate short-wavelength light, are being marketed to alleviate eyestrain and discomfort when using digital devices, improve sleep quality and potentially confer protection from retinal phototoxicity. The aim of this review was to investigate the relative benefits and potential harms of these lenses. METHODS We included randomised controlled trials (RCTs), recruiting adults from the general population, which investigated the effect of BB spectacle lenses on visual performance, symptoms of eyestrain or eye fatigue, changes to macular integrity and subjective sleep quality. We searched MEDLINE, EMBASE, the Cochrane Library and clinical trial registers, until 30 April 2017. Risk of bias was assessed using the Cochrane tool. RESULTS Three studies (with 136 participants) met our inclusion criteria; these had limitations in study design and/or implementation. One study compared the effect of BB lenses with clear lenses on contrast sensitivity (CS) and colour vision (CV) using a pseudo-RCT crossover design; there was no observed difference between lens types (log CS; Mean Difference (MD) = -0.01 [-0.03, 0.01], CV total error score on 100-hue; MD = 1.30 [-7.84, 10.44]). Another study measured critical fusion frequency (CFF), as a proxy for eye fatigue, on wearers of low and high BB lenses, pre- and post- a two-hour computer task. There was no observed difference between low BB and standard lens groups, but there was a less negative change in CFF between the high and low BB groups (MD = 1.81 [0.57, 3.05]). Both studies compared eyestrain symptoms with Likert scales. There was no evidence of inter-group differences for either low BB (MD = 0.00 [-0.22, 0.22]) or high BB lenses (MD = -0.05 [-0.31, 0.21]), nor evidence of a difference in the proportion of participants showing an improvement in symptoms of eyestrain or eye fatigue. One study reported a small improvement in sleep quality in people with self-reported insomnia after wearing high compared to low-BB lenses (MD = 0.80 [0.17, 1.43]) using a 10-point Likert scale. A study involving normal participants found no observed difference in sleep quality. We found no studies investigating effects on macular structure or function. CONCLUSIONS We find a lack of high quality evidence to support using BB spectacle lenses for the general population to improve visual performance or sleep quality, alleviate eye fatigue or conserve macular health.
Collapse
|
48
|
Bunce C, Lawrenson JG, Wormald R, Virgili G. Cochrane Risk of Bias : 'Your common man has no conception of the zeal that animates a scientific investigator, the fury of contradiction you can arouse in him'. Ophthalmic Physiol Opt 2017; 37:627-628. [PMID: 28836390 DOI: 10.1111/opo.12394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
49
|
Evans JR, Lawrenson JG. Antioxidant vitamin and mineral supplements for slowing the progression of age-related macular degeneration. Cochrane Database Syst Rev 2017; 7:CD000254. [PMID: 28756618 PMCID: PMC6483465 DOI: 10.1002/14651858.cd000254.pub4] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND It has been proposed that antioxidants may prevent cellular damage in the retina by reacting with free radicals that are produced in the process of light absorption. Higher dietary levels of antioxidant vitamins and minerals may reduce the risk of progression of age-related macular degeneration (AMD). OBJECTIVES The objective of this review was to assess the effects of antioxidant vitamin or mineral supplementation on the progression of AMD in people with AMD. SEARCH METHODS We searched CENTRAL (2017, Issue 2), MEDLINE Ovid (1946 to March 2017), Embase Ovid (1947 to March 2017), AMED (1985 to March 2017), OpenGrey (System for Information on Grey Literature in Europe, the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 29 March 2017. SELECTION CRITERIA We included randomised controlled trials (RCTs) that compared antioxidant vitamin or mineral supplementation (alone or in combination) to placebo or no intervention, in people with AMD. DATA COLLECTION AND ANALYSIS Both review authors independently assessed risk of bias in the included studies and extracted data. One author entered data into RevMan 5; the other author checked the data entry. We graded the certainty of the evidence using GRADE. MAIN RESULTS We included 19 studies conducted in USA, Europe, China, and Australia. We judged the trials that contributed data to the review to be at low or unclear risk of bias.Nine studies compared multivitamins with placebo (7 studies) or no treatment (2 studies) in people with early and moderate AMD. The duration of supplementation and follow-up ranged from nine months to six years; one trial followed up beyond two years. Most evidence came from the Age-Related Eye Disease Study (AREDS) in the USA. People taking antioxidant vitamins were less likely to progress to late AMD (odds ratio (OR) 0.72, 95% confidence interval (CI) 0.58 to 0.90; 2445 participants; 3 RCTs; moderate-certainty evidence). In people with very early signs of AMD, who are at low risk of progression, this would mean that there would be approximately 4 fewer cases of progression to late AMD for every 1000 people taking vitamins (1 fewer to 6 fewer cases). In people at high risk of progression (i.e. people with moderate AMD) this would correspond to approximately 8 fewer cases of progression for every 100 people taking vitamins (3 fewer to 13 fewer). In one study of 1206 people, there was a lower risk of progression for both neovascular AMD (OR 0.62, 95% CI 0.47 to 0.82; moderate-certainty evidence) and geographic atrophy (OR 0.75, 95% CI 0.51 to 1.10; moderate-certainty evidence) and a lower risk of losing 3 or more lines of visual acuity (OR 0.77, 95% CI 0.62 to 0.96; 1791 participants; moderate-certainty evidence). Low-certainty evidence from one study of 110 people suggested higher quality of life scores (National Eye Institute Visual Function Questionnaire) in treated compared with the non-treated people after 24 months (mean difference (MD) 12.30, 95% CI 4.24 to 20.36). Six studies compared lutein (with or without zeaxanthin) with placebo. The duration of supplementation and follow-up ranged from six months to five years. Most evidence came from the AREDS2 study in the USA. People taking lutein or zeaxanthin may have similar or slightly reduced risk of progression to late AMD (RR 0.94, 95% CI 0.87 to 1.01; 6891 eyes; low-certainty evidence), neovascular AMD (RR 0.92, 95% CI 0.84 to 1.02; 6891 eyes; low-certainty evidence), and geographic atrophy (RR 0.92, 95% CI 0.80 to 1.05; 6891 eyes; low-certainty evidence). A similar risk of progression to visual loss of 15 or more letters was seen in the lutein and control groups (RR 0.98, 95% CI 0.91 to 1.05; 6656 eyes; low-certainty evidence). Quality of life (measured with Visual Function Questionnaire) was similar between groups in one study of 108 participants (MD 1.48, 95% -5.53 to 8.49, moderate-certainty evidence). One study, conducted in Australia, compared vitamin E with placebo. This study randomised 1204 people to vitamin E or placebo, and followed up for four years. Participants were enrolled from the general population; 19% had AMD. The number of late AMD events was low (N = 7) and the estimate of effect was uncertain (RR 1.36, 95% CI 0.31 to 6.05, very low-certainty evidence). There were no data on neovascular AMD or geographic atrophy.There was no evidence of any effect of treatment on visual loss (RR 1.04, 95% CI 0.74 to 1.47, low-certainty evidence). There were no data on quality of life. Five studies compared zinc with placebo. The duration of supplementation and follow-up ranged from six months to seven years. People taking zinc supplements may be less likely to progress to late AMD (OR 0.83, 95% CI 0.70 to 0.98; 3790 participants; 3 RCTs; low-certainty evidence), neovascular AMD (OR 0.76, 95% CI 0.62 to 0.93; 2442 participants; 1 RCT; moderate-certainty evidence), geographic atrophy (OR 0.84, 95% CI 0.64 to 1.10; 2442 participants; 1 RCT; moderate-certainty evidence), or visual loss (OR 0.87, 95% CI 0.75 to 1.00; 3791 participants; 2 RCTs; moderate-certainty evidence). There were no data reported on quality of life.Very low-certainty evidence was available on adverse effects because the included studies were underpowered and adverse effects inconsistently reported. AUTHORS' CONCLUSIONS People with AMD may experience some delay in progression of the disease with multivitamin antioxidant vitamin and mineral supplementation. This finding was largely drawn from one large trial, conducted in a relatively well-nourished American population. We do not know the generalisability of these findings to other populations. Although generally regarded as safe, vitamin supplements may have harmful effects. A systematic review of the evidence on harms of vitamin supplements is needed. Supplements containing lutein and zeaxanthin are heavily marketed for people with age-related macular degeneration but our review shows they may have little or no effect on the progression of AMD.
Collapse
|
50
|
Evans JR, Lawrenson JG. Antioxidant vitamin and mineral supplements for preventing age-related macular degeneration. Cochrane Database Syst Rev 2017; 7:CD000253. [PMID: 28756617 PMCID: PMC6483250 DOI: 10.1002/14651858.cd000253.pub4] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND There is inconclusive evidence from observational studies to suggest that people who eat a diet rich in antioxidant vitamins (carotenoids, vitamins C, and E) or minerals (selenium and zinc) may be less likely to develop age-related macular degeneration (AMD). OBJECTIVES To determine whether or not taking antioxidant vitamin or mineral supplements, or both, prevent the development of AMD. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 2), MEDLINE Ovid (1946 to 29 March 2017), Embase Ovid (1947 to 29 March 2017), AMED (Allied and Complementary Medicine Database) (1985 to 29 March 2017), OpenGrey (System for Information on Grey Literature in Europe) (www.opengrey.eu/); searched 29 March 2017, the ISRCTN registry (www.isrctn.com/editAdvancedSearch); searched 29 March 2017, ClinicalTrials.gov (www.clinicaltrials.gov); searched 29 March 2017 and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en); searched 29 March 2017. We did not use any date or language restrictions in the electronic searches for trials. SELECTION CRITERIA We included all randomised controlled trials (RCTs) comparing an antioxidant vitamin or mineral supplement (alone or in combination) to control. DATA COLLECTION AND ANALYSIS Both review authors independently assessed risk of bias in the included studies and extracted data. One author entered data into RevMan 5; the other author checked the data entry. We pooled data using a fixed-effect model. We graded the certainty of the evidence using GRADE. MAIN RESULTS We included a total of five RCTs in this review with data available for 76,756 people. The trials were conducted in Australia, Finland, and the USA, and investigated vitamin C, vitamin E, beta-carotene, and multivitamin supplements. All trials were judged to be at low risk of bias.Four studies reported the comparison of vitamin E with placebo. Average treatment and follow-up duration ranged from 4 to 10 years. Data were available for a total of 55,614 participants. There was evidence that vitamin E supplements do not prevent the development of any AMD (risk ratio (RR) 0.97, 95% confidence interval (CI) 0.90 to 1.06; high-certainty evidence), and may slightly increase the risk of late AMD (RR 1.22, 95% CI 0.89 to 1.67; moderate-certainty evidence) compared with placebo. Only one study (941 participants) reported data separately for neovascular AMD and geographic atrophy. There were 10 cases of neovascular AMD (RR 3.62, 95% CI 0.77 to 16.95; very low-certainty evidence), and four cases of geographic atrophy (RR 2.71, 95% CI 0.28 to 26.0; very low-certainty evidence). Two trials reported similar numbers of adverse events in the vitamin E and placebo groups. Another trial reported excess of haemorrhagic strokes in the vitamin E group (39 versus 23 events, hazard ratio 1.74, 95% CI 1.04 to 2.91, low-certainty evidence).Two studies reported the comparison of beta-carotene with placebo. These studies took place in Finland and the USA. Both trials enrolled men only. Average treatment and follow-up duration was 6 years and 12 years. Data were available for a total of 22,083 participants. There was evidence that beta-carotene supplements did not prevent any AMD (RR 1.00, 95% CI 0.88 to 1.14; high-certainty evidence) nor have an important effect on late AMD (RR 0.90, 95% CI 0.65 to 1.24; moderate-certainty evidence). Only one study (941 participants) reported data separately for neovascular AMD and geographic atrophy. There were 10 cases of neovascular AMD (RR 0.61, 95% CI 0.17 to 2.15; very low-certainty evidence) and 4 cases of geographic atrophy (RR 0.31 95% CI 0.03 to 2.93; very low-certainty evidence). Beta-carotene was associated with increased risk of lung cancer in people who smoked.One study reported the comparison of vitamin C with placebo, and multivitamin (Centrum Silver) versus placebo. This was a study in men in the USA with average treatment duration and follow-up of 8 years for vitamin C and 11 years for multivitamin. Data were available for a total of 14,236 participants. AMD was assessed by self-report followed by medical record review. There was evidence that vitamin C supplementation did not prevent any AMD (RR 0.96, 95% CI 0.79 to 1.18; high-certainty evidence) or late AMD (RR 0.94, 0.61 to 1.46; moderate-certainty evidence). There was a slight increased risk of any AMD (RR 1.21, 95% CI 1.02 to 1.43; moderate-certainty evidence) and late AMD (RR 1.22, 95% CI 0.88 to 1.69; moderate-certainty evidence) in the multivitamin group. Neovascular AMD and geographic atrophy were not reported separately. Adverse effects were not reported but there was possible increased risk of skin rashes in the multivitamin group.Adverse effects were not consistently reported in these eye studies, but there is evidence from other large studies that beta-carotene increases the risk of lung cancer in people who smoke or who have been exposed to asbestos.None of the studies reported quality of life or resource use and costs. AUTHORS' CONCLUSIONS Taking vitamin E or beta-carotene supplements will not prevent or delay the onset of AMD. The same probably applies to vitamin C and the multivitamin (Centrum Silver) investigated in the one trial reported to date. There is no evidence with respect to other antioxidant supplements, such as lutein and zeaxanthin. Although generally regarded as safe, vitamin supplements may have harmful effects, and clear evidence of benefit is needed before they can be recommended. People with AMD should see the related Cochrane Review on antioxidant vitamin and mineral supplements for slowing the progression of AMD, written by the same review team.
Collapse
|