26
|
Poirier MP, Blacklock R, Cao M, Théoret D, Frei L, Gagnon P. Technical-tactical behavior analysis of general duty police officers during non-compliant suspect apprehensions: A novel approach to establish minimum force requirements. Work 2024; 77:1341-1357. [PMID: 38552129 DOI: 10.3233/wor-230307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/06/2024] Open
Abstract
BACKGROUND While effective apprehensions of non-compliant suspects are central to public safety, the minimal force needed to transition a suspect from standing to the ground, vital for apprehension success, has not been established. OBJECTIVE To examine the technical-tactical behaviors of general duty police officers during simulated apprehensions and quantify the minimum force required to destabilize non-compliant suspects. METHODS Task simulations conducted with 91 officers were analyzed to identify common grappling movements, strikes, control tactics, and changes in body posture. A separate assessment of 55 male officers aimed to determine the minimum force required for destabilization in five body regions (wrist, forearm, shoulder, mid-chest, and mid-back). Data are presented as mean±standard deviation. RESULTS On average, apprehensions took 7.3±3.2 seconds. While all officers used grappling movements (100%) and the majority employed control tactics (75%), strikes were seldom used (4%). Apprehensions typically began with a two-handed pull (97%; Contact Phase), 55% then attempted an arm bar takedown, followed by a two-handed cross-body pull (68%; Transition/Control Phase), and a two-handed push to the ground (19%; Ground Phase). All officers began in the upright posture, with most shifting to squat (75%), kneel (58%), or bent (45%) postures to complete the apprehension. The minimum force required to disrupt balance differed across body regions (wrist: 54±12 kg; forearm: 49±12 kg; shoulder: 42±10 kg; mid-chest: 44±11 kg; mid-back: 30±7 kg, all P < 0.05), except between the shoulder and chest (P = 0.19). CONCLUSION These findings provide insights that can enhance the design and accuracy of future apprehension evaluations and inform the optimization of law enforcement physical employment standards.
Collapse
|
27
|
Pincet L, Pincet F. Membrane Tubulation with a Biomembrane Force Probe. MEMBRANES 2023; 13:910. [PMID: 38132914 PMCID: PMC10744658 DOI: 10.3390/membranes13120910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 12/09/2023] [Accepted: 12/12/2023] [Indexed: 12/23/2023]
Abstract
Tubulation is a common cellular process involving the formation of membrane tubes ranging from 50 nm to 1 µm in diameter. These tubes facilitate intercompartmental connections, material transport within cells and content exchange between cells. The high curvature of these tubes makes them specific targets for proteins that sense local geometry. In vitro, similar tubes have been created by pulling on the membranes of giant unilamellar vesicles. Optical tweezers and micromanipulation are typically used in these experiments, involving the manipulation of a GUV with a micropipette and a streptavidin-coated bead trapped in optical tweezers. The interaction forms streptavidin/biotin bonds, leading to tube formation. Here, we propose a cost-effective alternative using only micromanipulation techniques, replacing optical tweezers with a Biomembrane Force Probe (BFP). The BFP, employing a biotinylated erythrocyte as a nanospring, allows for the controlled measurement of forces ranging from 1 pN to 1 nN. The BFP has been widely used to study molecular interactions in cellular processes, extending beyond its original purpose. We outline the experimental setup, tube formation and characterization of tube dimensions and energetics, and discuss the advantages and limitations of this approach in studying membrane tubulation.
Collapse
|
28
|
Cabarkapa D, Cabarkapa DV, Aleksic J, Philipp NM, Scott AA, Johnson QR, Fry AC. Differences in countermovement vertical jump force-time metrics between starting and non-starting professional male basketball players. Front Sports Act Living 2023; 5:1327379. [PMID: 38162698 PMCID: PMC10755471 DOI: 10.3389/fspor.2023.1327379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 11/23/2023] [Indexed: 01/03/2024] Open
Abstract
With force plates being widely implemented for neuromuscular performance assessment in sport-specific settings and various force-time metrics being able to differentiate athletes based on their performance capabilities, the purpose of the present study was to examine the differences in countermovement vertical jump (CVJ) characteristics between starting and non-starting professional male basketball players (e.g., ABA League). Twenty-three athletes (height = 199.2 ± 7.7 kg, body mass = 94.2 ± 8.2 kg, age = 23.8 ± 4.9 years) volunteered to participate in the present investigation. Upon completion of a standardized warm-up protocol, each athlete performed three maximal-effort CVJs without an arm swing while standing on a uni-axial force plate system sampling at 1,000 Hz. Independent t-tests were used to examine statistically significant differences (p < 0.05) in each force-time metric between starters (n = 10) and non-starters (n = 13). No significant differences in any of the CVJ force-time metrics of interest were observed between the two groups, during both the eccentric and concentric phases of the movement (i.e., impulse, duration, peak velocity, and mean and peak force and power). Moreover, starters and non-starters demonstrated similar performance on CVJ outcome (e.g., jump height) and strategy metrics (e.g., countermovement depth). Overall, these findings suggest that at the professional level of play, the ability to secure a spot in the starting lineup is not primarily determined by the players' CVJ performance characteristics.
Collapse
|
29
|
Leslie O, Córdova Bulens D, Redmond SJ. Design, Fabrication, and Characterization of a Novel Optical Six-Axis Distributed Force and Displacement Tactile Sensor for Dexterous Robotic Manipulation. SENSORS (BASEL, SWITZERLAND) 2023; 23:9640. [PMID: 38139486 PMCID: PMC10748078 DOI: 10.3390/s23249640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/24/2023] [Accepted: 12/01/2023] [Indexed: 12/24/2023]
Abstract
Real-time multi-axis distributed tactile sensing is a critical capability if robots are to perform stable gripping and dexterous manipulation, as it provides crucial information about the sensor-object interface. In this paper, we present an optical-based six-axis tactile sensor designed in a fingertip shape for robotic dexterous manipulation. The distributed sensor can precisely estimate the local XYZ force and displacement at ten distinct locations and provide the global XYZ force and torque measurements. Its compact size, comparable to that of a human thumb, and minimal thickness allow seamless integration onto existing robotic fingers, eliminating the need for complex modifications to the gripper. The proposed sensor design uses a simple, low-cost fabrication method. Moreover, the optical transduction approach uses light angle and intensity sensing to infer force and displacement from deformations of the individual sensing units that form the overall sensor, providing distributed six-axis sensing. The local force precision at each sensing unit in the X, Y, and Z axes is 20.89 mN, 19.19 mN, and 43.22 mN, respectively, over a local force range of approximately ±1.5 N in X and Y and 0 to -2 N in Z. The local displacement precision in the X, Y, and Z axes is 56.70 μm, 50.18 μm, and 13.83 μm, respectively, over a local displacement range of ±2 mm in the XY directions and 0 to -1.5 mm in Z (i.e., compression). Additionally, the sensor can measure global torques, Tx, Ty, and Tz, with a precision of of 1.90 N-mm, 1.54 N-mm, and 1.26 N-mm, respectively. The fabricated design is showcased by integrating it with an OnRobot RG2 gripper and illustrating real-time measurements during in simple demonstration task, which generated changing global forces and torques.
Collapse
|
30
|
Philipp NM, Cabarkapa D, Nijem RM, Blackburn SD, Fry AC. Vertical Jump Neuromuscular Performance Characteristics Determining On-Court Contribution in Male and Female NCAA Division 1 Basketball Players. Sports (Basel) 2023; 11:239. [PMID: 38133106 PMCID: PMC10748117 DOI: 10.3390/sports11120239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 11/17/2023] [Accepted: 11/27/2023] [Indexed: 12/23/2023] Open
Abstract
While various quantifiable physical attributes have been found to contribute to athletes' performance, there is a lack of scientific literature focused on examining how they relate to success during competition performance. The aim of this study was to investigate different countermovement jump (CMJ)-derived force-time characteristics and their utility in distinguishing high from low performers within a measure of on-court contribution (i.e., minutes per game played). Twenty-nine collegiate athletes (n = 15 males and n = 14 females) volunteered to participate in this investigation and performed CMJs on dual force plates sampling at 1000 Hz, weekly over the course of their basketball season. The athletes' average of their three best test-days across the season was used for further analysis. To identify their on-court contribution, athletes were divided into groups with high and low minutes per game, based on a median-split analysis. The findings suggest that at the overall group level (i.e., both genders), the modified reactive strength index (mRSI) and braking rate of force development (RFD) revealed the greatest between-group magnitudes of difference, with athletes playing more minutes per game showing greater performance. At the team-specific level, the braking RFD, average braking velocity, and mRSI were shown to be the greatest differentiators between groups for the men's team. The women's high-minutes group displayed greater magnitudes of mRSI and jump height. By identifying the neuromuscular qualities seen in top performers within their respective populations, the attributed physical performance underpinning these qualities may be identified, providing practitioners with insights into physical performance qualities and training methodologies that have the potential to influence basketball performance.
Collapse
|
31
|
Charters E, Stokan M, Cheng K, Dunn M, Manzie T, Clark JR. Minimum detectable change in occlusal load - normative data for healthy and head and neck cancer populations. Br J Oral Maxillofac Surg 2023; 61:686-690. [PMID: 37953108 DOI: 10.1016/j.bjoms.2023.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2023] [Revised: 08/01/2023] [Accepted: 09/06/2023] [Indexed: 11/14/2023]
Abstract
Traditionally, pain has been a signal to de-intensify jaw exercises for trismus to prevent tissue damage. It is unknown whether patients who have undergone surgery or radiotherapy for head and neck cancer have sufficient sensation to detect changes in occlusal load. This study sought to compare the minimum detectable occlusal load in a cohort of patients with head and neck cancer (HNC) and compare this with healthy controls. Twenty patients who were treated for HNC and 20 healthy controls were recruited from a single institution. A purpose-built pressure transducer was used to measure the minimum detectable force (measured in Newtons) applied to the jaw and the interincisal distance. Analysis was conducted using a mixed effects linear regression. The mean minimum detectable occlusal load in patients with HNC was 18.7N compared to 4.5N in healthy controls (mean difference 14.3N, 95% CI 12.2N to 16.4N, p < 0.001). Adjusted IID predicted force (0.15N per-mm IID, 95% CI 0.09 to 0.2, p < 0.001) with a weak interaction between treatment with radiotherapy and IID in HNC patients (p = 0.85). Patients who have been treated for HNC are less sensitive to changes in force applied to the jaw. This is concerning given that most jaw stretching devices use an unregulated and unknown amount of force to achieve greater mouth opening.
Collapse
|
32
|
Perrey S. The potential of fNIRS, EEG, and transcranial current stimulation to probe neural mechanisms of resistance training. Front Hum Neurosci 2023; 17:1295993. [PMID: 38098763 PMCID: PMC10720034 DOI: 10.3389/fnhum.2023.1295993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 11/16/2023] [Indexed: 12/17/2023] Open
|
33
|
Sugawara SK, Yamamoto T, Nakayama Y, Hamano YH, Fukunaga M, Sadato N, Nishimura Y. Premovement activity in the mesocortical system links peak force but not initiation of force generation under incentive motivation. Cereb Cortex 2023; 33:11408-11419. [PMID: 37814358 PMCID: PMC10690858 DOI: 10.1093/cercor/bhad376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 09/22/2023] [Accepted: 09/22/2023] [Indexed: 10/11/2023] Open
Abstract
Motivation facilitates motor performance; however, the neural substrates of the psychological effects on motor performance remain unclear. We conducted a functional magnetic resonance imaging experiment while human subjects performed a ready-set-go task with monetary incentives. Although subjects were only motivated to respond quickly, increasing the incentives improved not only reaction time but also peak grip force. However, the trial-by-trial correlation between reaction time and peak grip force was weak. Extensive areas in the mesocortical system, including the ventral midbrain (VM) and cortical motor-related areas, exhibited motivation-dependent activity in the premovement "Ready" period when the anticipated monetary reward was displayed. This premovement activity in the mesocortical system correlated only with subsequent peak grip force, whereas the activity in motor-related areas alone was associated with subsequent reaction time and peak grip force. These findings suggest that the mesocortical system linking the VM and motor-related regions plays a role in controlling the peak of force generation indirectly associated with incentives but not the initiation of force generation.
Collapse
|
34
|
Parsowith EJ, Stock MS, Girts RM, Beausejour JP, Alberto A, Carr JC, Harmon KK. The Influence of Resistance Training Experience on the Efficacy of Motor Imagery for Acutely Increasing Corticospinal Excitability. Brain Sci 2023; 13:1635. [PMID: 38137083 PMCID: PMC10742069 DOI: 10.3390/brainsci13121635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 11/15/2023] [Accepted: 11/23/2023] [Indexed: 12/24/2023] Open
Abstract
Both motor imagery and resistance-training enhance motor function and corticospinal excitability. We tested the hypothesis that young participants with significant resistance-training experience would show heightened corticospinal excitability during a single session of motor imagery training. Fifty-six participants (mean ± SD age = 22 ± 2 years) were divided into resistance-trained and untrained groups. Forty-one upper-body resistance trained (21 males, 20 females; mean ± SD relative one repetition maximum bench press = 0.922 ± 0.317 kg/kg) and 15 untrained (4 males, 11 females; mean ± SD relative one repetition maximum bench press = 0.566 ± 0.175 kg/kg) participants visited the laboratory on three separate occasions. The first visit served as the familiarization session. During visits 2 and 3, participants engaged in a hand/wrist motor imagery protocol or rested quietly (control condition) in a randomized order. Before and after the interventions, single-pulse transcranial magnetic stimulation (TMS) over the motor cortex was used to measure resting motor-evoked potential amplitude of the first dorsal interosseous muscle. Our main finding was that motor imagery acutely increased corticospinal excitability by ~64% (marginal means pre = 784.1 µV, post = 1246.6 µV; p < 0.001, d = 0.487). However, there was no evidence that the increase in corticospinal excitability was influenced by resistance-training experience. We suspect that our results may have been influenced by the specific nature of the motor imagery task. Our findings have important implications for motor imagery prescription and suggest that motor imagery training may be equally beneficial for both resistance-trained and untrained populations. This study was prospectively registered at ClinicalTrials.gov (Identifier: NCT03889548).
Collapse
|
35
|
Katić Križmančić I, Salopek Čubrić I, Potočić Matković VM, Čubrić G. Changes in Mechanical Properties of Fabrics Made of Standard and Recycled Polyester Yarns Due to Aging. Polymers (Basel) 2023; 15:4511. [PMID: 38231927 PMCID: PMC10708220 DOI: 10.3390/polym15234511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 11/22/2023] [Accepted: 11/22/2023] [Indexed: 01/19/2024] Open
Abstract
Over the years, the demands on the durability and quality of polyester fabrics used for sportswear have increased, as these fabrics contribute to athletes' performance. At the same time, the use of recycled polyester material is increasingly being promoted for environmental reasons. This study focused on investigating the properties of standard and recycled polyester fabrics before and after aging according to the developed aging protocol. The surface morphology, thickness, elongation at break, force at break, bursting force, mass loss due to abrasion and moisture management of the fabrics were tested. The results showed that the aging process had no influence on the surface changes in the fabrics. More specifically, there were neither surface cracks on the fibre surface nor chemical changes. The highest decrease in force at break for standard polyester fabrics with elastane was up to 26%, and up to 15% for fabrics made of recycled polyester. The loss of mass due to abrasion was greater for recycled polyester than for standard polyester fabrics. The average ability of the fabrics to absorb moisture decreased by up to 23% after aging, while the wetting time increased by up to 30%, with the highest increase observed in recycled fabrics.
Collapse
|
36
|
Chung JW, Bower AE, Malik I, Martello JP, Knight CA, Jeka JJ, Burciu RG. fMRI changes during multi-limb movements in Parkinson's disease. Front Hum Neurosci 2023; 17:1248636. [PMID: 38021235 PMCID: PMC10665733 DOI: 10.3389/fnhum.2023.1248636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 09/29/2023] [Indexed: 12/01/2023] Open
Abstract
BackgroundWhile motor coordination problems are frequently reported among individuals with Parkinson’s disease (PD), the effects of the disease on the performance of multi-limb movements and the brain changes underlying impaired coordination are not well-documented.ObjectiveFunctional magnetic resonance imaging (fMRI) was used to examine differences in brain activity during a task that involved the coordination of non-homologous limbs (i.e., ipsilateral hand and foot) in individuals with and without PD.MethodsParticipants included 20 PD and 20 healthy control participants (HC). They were instructed to generate force in a coordinated manner by simultaneously contracting their ipsilateral hand and foot. PD were tested off their antiparkinsonian medication and on their more affected side, whereas the side in controls was randomized.ResultsAlthough both groups were able to coordinate the two limbs to produce the expected level of force, PD had a slower rate of force production and relaxation compared to HC. Additionally, their globus pallidus and primary motor cortex were underactive, whereas their pre-supplementary motor area (pre-SMA) and lateral cerebellum were overactive relative to HC. Importantly, in PD, the fMRI activity within the pre-SMA correlated with the rate of force decrease.ConclusionMulti-limb force control deficits in PD appear to be related to widespread underactivation within the basal ganglia-cortical loop. An overactivation of higher-level motor regions within the prefrontal cortex and lateral cerebellum may reflect increased cognitive control and performance monitoring that emerges during more complex motor tasks such as those that involve the coordination of multiple limbs.
Collapse
|
37
|
Mohamed-Saaid F, Sulaiman AR, Munajat I, Mohd EF, Arifin WN, Ghafar R. The Effects of Different Degrees of Leg Length Discrepancy on Vertical Ground Reaction Force in Children and Adults: Treatment Implications. Malays Orthop J 2023; 17:66-72. [PMID: 38107356 PMCID: PMC10723003 DOI: 10.5704/moj.2311.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 03/22/2023] [Indexed: 12/19/2023] Open
Abstract
Introduction Previous studies on the degree of leg length discrepancy that causes limb biomechanical problems did not differentiate between adults and children. We conducted this study to determine the effects of simulated leg length discrepancy on vertical ground reaction force in children and adults to enable decision-making for intervention in patients with leg length discrepancy for different age groups or heights. Materials and methods This cross-sectional study involved male volunteers of children 150cm and adults with 170cm in height. Vertical ground reaction force was measured using a gait analysis study. The first measurement was taken without any leg length discrepancy as a baseline. Subsequently, different amounts of leg length discrepancy were simulated on the left leg with shoe lifts of 2, 3, and 4cm. The measurements were repeated on each volunteer with similar shoe lifts on the right leg. Therefore, 14 volunteers provided simulations of 28 leg length discrepancies for each group. The first and second peaks of vertical ground reaction force were separately analysed. The vertical GRF of a simulated leg length discrepancy was compared with the baseline. Repeated measurement of analysis of variance (ANOVA) within each group was done. Results In both groups, the second peak of vertical ground reaction force in the longer leg reduced gradually as the shoe lift increased sequentially from 2 to 3cm and then to 4cm. A discrepancy of 3cm and above was statistically significant to cause a reduction in the vertical GRF on the longer limb in both height groups. Conclusion The degree of leg length discrepancy that caused significant changes in second peak ground reaction force in children with 150 and adults with 170cm height population was similar at 3cm. Therefore, the cut-off point for intervention for both groups are similar with additional consideration of future growth in children.
Collapse
|
38
|
Waiteman MC, Garcia MC, Briani RV, Norte G, Glaviano NR, De Azevedo FM, Bazett-Jones DM. Can Clinicians Trust Objective Measures of Hip Muscle Strength From Portable Dynamometers? A Systematic Review With Meta-analysis and Evidence Gap Map of 107 Studies of Reliability and Criterion Validity Using the COSMIN Methodology. J Orthop Sports Phys Ther 2023; 53:655-672. [PMID: 37787581 DOI: 10.2519/jospt.2023.12045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
OBJECTIVE: To summarize the evidence on reliability and criterion validity of hip muscle strength testing using portable dynamometers. DESIGN: Systematic review with meta-analysis. LITERATURE SEARCH: Five databases were searched from inception to March 2023. STUDY SELECTION CRITERIA: We included studies investigating reliability or criterion validity of hip flexor, extensor, abductor, adductor, or internal/external rotator strength testing with portable dynamometers in injury-free individuals or those with pelvic/lower limb musculoskeletal disorders. DATA SYNTHESIS: We performed meta-analyses for each muscle group, position, and method of fixation. We rated pooled results as sufficient (>75% of studies with correlations ≥0.70), insufficient (>75% of studies with correlations <0.70), or inconsistent (sufficient/insufficient results). We assessed the quality of evidence, created evidence gap maps, and made clinical recommendations. RESULTS: We included a total of 107 studies (reliability 103, validity 14). The intrarater and interrater reliability for hip muscle strength testing across different positions and methods of fixation was sufficient (intraclass correlation coefficient = 0.78-0.96) with low- to high-quality evidence. Criterion validity was less investigated and mostly inconsistent (very low-to moderate-quality evidence) with a wide range of correlations (r = 0.40-0.93). CONCLUSION: Hip muscle strength testing using portable dynamometers is reliable. The use of portable dynamometers as clinical surrogates for measuring strength using an isokinetic dynamometer requires further investigation. Clinicians testing hip muscle strength with portable dynamometers should use external fixation seated for hip flexors, prone or supine for hip extensors, side-lying or supine for abductors and adductors, and prone and seated for internal and external rotators. J Orthop Sports Phys Ther 2023;53(11):655-672. Epub 3 October 2023. doi:10.2519/jospt.2023.12045.
Collapse
|
39
|
Wei B. The tendency of the schematic structure to maintain stability can be interpreted as mental inertia. Front Psychol 2023; 14:1243711. [PMID: 38022980 PMCID: PMC10646405 DOI: 10.3389/fpsyg.2023.1243711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Accepted: 10/17/2023] [Indexed: 12/01/2023] Open
Abstract
This paper incorporates schematic concepts related to mental inertia and provides an avenue for interpreting psychology using the principles of classical mechanics. Schemas find wide application in diverse fields, ranging from ergonomics to psychotherapy. Nonetheless, it is crucial to incorporate schemas themselves into a more unified and comprehensive theoretical framework. Drawing upon the free energy principle (FEP) and the second law of thermodynamics, it is evident that humans possess a natural inclination to construct and maintain consistent cognitive structures. This characteristic contributes to the stability of schemas within a defined range. The particular scope of the model is closely intertwined with its structure, leading to variations among individuals in diverse environments. The coherence of the schema within a defined range can be perceived as the magnitude of mental inertia. This psychological analogy emphasizes the importance of considering the influences exerted by the external environment and their effects on mental inertia when predicting the human mind and behavior.
Collapse
|
40
|
Baker J. The Problem with Inventing Molecular Mechanisms to Fit Thermodynamic Equations of Muscle. Int J Mol Sci 2023; 24:15439. [PMID: 37895118 PMCID: PMC10607768 DOI: 10.3390/ijms242015439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 10/16/2023] [Accepted: 10/17/2023] [Indexed: 10/29/2023] Open
Abstract
Almost every model of muscle contraction in the literature to date is a molecular power stroke model, even though this corpuscular mechanism is opposed by centuries of science, by 85 years of unrefuted evidence that muscle is a thermodynamic system, and by a quarter century of direct observations that the molecular mechanism of muscle contraction is a molecular switch, not a molecular power stroke. An ensemble of molecular switches is a binary mechanical thermodynamic system from which A.V. Hill's muscle force-velocity relationship is directly derived, where Hill's parameter a is the internal force against which unloaded muscle shortens, and Hill's parameter b is the product of the switch displacement, d, and the actin-myosin ATPase rate. Ignoring this model and the centuries of thermodynamics that preceded it, corpuscularians continue to develop molecular power stroke models, adding to their 65-year jumble of "new", "innovative", and "unconventional" molecular mechanisms for Hill's a and b parameters, none of which resemble the underlying physical chemistry. Remarkably, the corpuscularian community holds the thermodynamicist to account for these discrepancies, which, as outlined here, I have done for 25 years. It is long past time for corpuscularians to be held accountable for their mechanisms, which by all accounts have no foundation in science. The stakes are high. Molecular power stroke models are widely used in research and in clinical decision-making and have, for over half a century, muddied our understanding of the inner workings of one of the most efficient and clean-burning machines on the planet. It is problematic that corpuscularians present these models to stakeholders as science when in fact corpuscularians have been actively defending these models against science for decades. The path forward for scientists is to stop baseless rejections of muscle thermodynamics and to begin testing corpuscular and thermodynamic mechanisms with the goal of disproving one or the other of these hypotheses.
Collapse
|
41
|
Saccomanno S, Quinzi V, Paskay LC, Caccone L, Rasicci L, Fani E, Di Giandomenico D, Marzo G. Evaluation of the Loss of Strength, Resistance, and Elasticity in the Different Types of Intraoral Orthodontic Elastics (IOE): A Systematic Review of the Literature of In Vitro Studies. J Pers Med 2023; 13:1495. [PMID: 37888106 PMCID: PMC10608549 DOI: 10.3390/jpm13101495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/01/2023] [Accepted: 10/04/2023] [Indexed: 10/28/2023] Open
Abstract
BACKGROUND Intraoral orthodontic elastics (IOE), typically referred to as rubber bands, are important tools for correcting malocclusion, and they are classified into latex and synthetic (elastomeric-based) elastics. They have different strengths and sizes, depending on their intended use, that provide clinicians with the ability to correct both anteroposterior and vertical discrepancies. Clinical use, together with saliva, alters the physical characteristics of both latex and synthetic elastics, causing declines in strength over time. AIM The aim of the study was to assess, through a systematic review of in vitro studies, the properties of intraoral elastics. The primary goal was to evaluate how IOEs behave in terms of tension strength and duration. The secondary goal was to investigate the force loss during the first hours of wear. The tertiary goal was to assess how these forces decayed. MATERIALS AND METHODS The following electronic databases were searched from December 2020 to April 2021: Medline Full Text, PubMed, Cochrane Clinical Trials Register, Science Direct, and Literature Review. Out of 8505 initial articles, 10 were selected for the systematic review. RESULTS The force-degradation property was found in all types of IOEs. The loss of strength was directly proportional to time, with the highest value during the first 3 h after extension, regardless of the elastic band size and manufacturer. The forces generated by the latex bands were higher than in those of the elastomeric-based elastics, but they did not consistently correspond to the loads specified by the manufacturers. The retention forces in the latex IOEs were significantly higher than those in the nonlatex bands, suggesting that elastomeric-based bands need to be changed more frequently and at regular intervals throughout a 24 h period. CONCLUSION This systematic review indicates that intraoral orthodontic elastics have the greatest loss of force during the first 3 h, that latex rubber bands have the highest strength during the first hour, that the forces generated are not always consistent with the manufacturer's specifications, and that nonlatex (elastomeric-based) IOEs need to be changed frequently and regularly during a 24-h cycle.
Collapse
|
42
|
Gans Š, Molnár J, Kováč D, Kováčová I, Fecko B, Bereš M, Jacko P, Dziak J, Vince T. Driving Signal and Geometry Analysis of a Magnetoelastic Bending Mode Pressductor Type Sensor. SENSORS (BASEL, SWITZERLAND) 2023; 23:8393. [PMID: 37896487 PMCID: PMC10610725 DOI: 10.3390/s23208393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/05/2023] [Accepted: 10/09/2023] [Indexed: 10/29/2023]
Abstract
The paper deals with a brief overview of magnetoelastic sensors and magnetoelastic sensors used in general for sensing bending forces, either directly or sensing bent structures, and defines the current state of the art. Bulk magnetoelastic force sensors are usually manufactured from transformer sheets or amorphous alloys. In praxis, usually, a compressive force is sensed by bulk magnetoelastic sensors; however, in this paper, the sensor is used for the measurement of bending forces, one reason being that the effect of such forces is easily experimentally tested, whereas compressive forces acting on a single sheet make buckling prevention a challenge. The measurement of the material characteristics that served as inputs into a FEM simulation model of the sensor is presented and described. The used material was considered to be mechanically and magnetically isotropic and magnetically nonlinear, even though the real sheet showed anisotropic behavior to some degree. A sinusoidal magnetizing current waveform was used in the experimental part of this paper, which was created by a current source. The effects of various frequencies, amplitudes, and sensor geometries were tested. The experimental part of this paper studies the sensors' RMS voltage changes to different loadings that bend the sheet out of its plane. The output voltage was the induced voltage in the secondary coil and was further analyzed to compute the linearity and sensitivity of the sensor at the specific current characteristic. It was found that for the given material, the most favorable operating conditions are obtained with higher frequency signals and higher excitation current amplitudes. The linearity of the sensor can be improved by placing the holes of the windings at different angles than 90° and by placing them further apart along the sheet's length. The current source was created by a simple op-amp voltage-to-current source controlled by a signal generator, which created a stable waveform. It was found that transformer sheet bending sensors with the dimensions described in this paper are suitable for the measurement of small forces in the range of up to 2 N for the shorter sensors and approximately 0.2 N for the longer sensors.
Collapse
|
43
|
Vantieghem-Nicolas L, Morin JB, Cotte T, Sangnier S, Rossi J. Concurrent Validity and Reliability of the Sprint Force-Velocity Profile Assessed with K-AI Wearable Tech. SENSORS (BASEL, SWITZERLAND) 2023; 23:8189. [PMID: 37837018 PMCID: PMC10575115 DOI: 10.3390/s23198189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 09/10/2023] [Accepted: 09/26/2023] [Indexed: 10/15/2023]
Abstract
Establishing a sprint acceleration force-velocity profile is a way to assess an athlete's sprint-specific strength and speed production capacities. It can be determined in field condition using GNSS-based (global navigation satellite system) devices. The aims of this study were to (1) assess the inter-unit and the inter-trial reliability of the force-velocity profile variables obtained with K-AI Wearable Tech devices (50 Hz), (2) assess the concurrent validity of the input variables (maximal sprint speed and acceleration time constant), and (3) assess the validity of the output variables (maximal force output, running velocity and power). Twelve subjects, including one girl, performed forty-one 30 m sprints in total, during which the running speed was measured using two GPS (global positioning system) devices placed on the upper back and a radar (Stalker® Pro II Sports Radar Gun). Concurrent validity, inter-device and inter-trial reliability analyses were carried out for the input and output variables. Very strong to poor correlation (0.99 to 0.38) was observed for the different variables between the GPS and radar devices, with typical errors ranging from small to large (all < 7.6%). Inter-unit reliability was excellent to moderate depending on the variable (ICC values between 0.65 and 0.99). Finally, for the inter-trial reliability, the coefficients of variation were low to very low (all < 5.6%) for the radar and the GPS. The K-AI Wearable Tech used in this study is a concurrently valid and reliable alternative to radar for assessing a sprint acceleration force-velocity profile.
Collapse
|
44
|
Timmermans M, Massalimova A, Li R, Davoodi A, Goossens Q, Niu K, Vander Poorten E, Fürnstahl P, Denis K. State-of-the-Art of Non-Radiative, Non-Visual Spine Sensing with a Focus on Sensing Forces, Vibrations and Bioelectrical Properties: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:8094. [PMID: 37836924 PMCID: PMC10574884 DOI: 10.3390/s23198094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 09/04/2023] [Accepted: 09/11/2023] [Indexed: 10/15/2023]
Abstract
In the research field of robotic spine surgery, there is a big upcoming momentum for surgeon-like autonomous behaviour and surgical accuracy in robotics which goes beyond the standard engineering notions such as geometric precision. The objective of this review is to present an overview of the state of the art in non-visual, non-radiative spine sensing for the enhancement of surgical techniques in robotic automation. It provides a vantage point that facilitates experimentation and guides new research projects to what has not been investigated or integrated in surgical robotics. Studies were identified, selected and processed according to the PRISMA guidelines. Relevant study characteristics that were searched for include the sensor type and measured feature, the surgical action, the tested sample, the method for data analysis and the system's accuracy of state identification. The 6DOF f/t sensor, the microphone and the electromyography probe were the most commonly used sensors in each category, respectively. The performance of the electromyography probe is unsatisfactory in terms of preventing nerve damage as it can only signal after the nerve is disturbed. Feature thresholding and artificial neural networks were the most common decision algorithms for state identification. The fusion of different sensor data in the decision algorithm improved the accuracy of state identification.
Collapse
|
45
|
Gergely ZR, Jones MH, Zhou B, Cash C, McIntosh JR, Betterton MD. Distinct regions of the kinesin-5 C-terminal tail are essential for mitotic spindle midzone localization and sliding force. Proc Natl Acad Sci U S A 2023; 120:e2306480120. [PMID: 37725645 PMCID: PMC10523502 DOI: 10.1073/pnas.2306480120] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 07/05/2023] [Indexed: 09/21/2023] Open
Abstract
Kinesin-5 motor proteins play essential roles during mitosis in most organisms. Their tetrameric structure and plus-end-directed motility allow them to bind to and move along antiparallel microtubules, thereby pushing spindle poles apart to assemble a bipolar spindle. Recent work has shown that the C-terminal tail is particularly important to kinesin-5 function: The tail affects motor domain structure, ATP hydrolysis, motility, clustering, and sliding force measured for purified motors, as well as motility, clustering, and spindle assembly in cells. Because previous work has focused on presence or absence of the entire tail, the functionally important regions of the tail remain to be identified. We have therefore characterized a series of kinesin-5/Cut7 tail truncation alleles in fission yeast. Partial truncation causes mitotic defects and temperature-sensitive growth, while further truncation that removes the conserved BimC motif is lethal. We compared the sliding force generated by cut7 mutants using a kinesin-14 mutant background in which some microtubules detach from the spindle poles and are pushed into the nuclear envelope. These Cut7-driven protrusions decreased as more of the tail was truncated, and the most severe truncations produced no observable protrusions. Our observations suggest that the C-terminal tail of Cut7p contributes to both sliding force and midzone localization. In the context of sequential tail truncation, the BimC motif and adjacent C-terminal amino acids are particularly important for sliding force. In addition, moderate tail truncation increases midzone localization, but further truncation of residues N-terminal to the BimC motif decreases midzone localization.
Collapse
|
46
|
Arce-McShane FI, Sessle BJ, Ram Y, Ross CF, Hatsopoulos NG. Multiple regions of sensorimotor cortex encode bite force and gape. Front Syst Neurosci 2023; 17:1213279. [PMID: 37808467 PMCID: PMC10556252 DOI: 10.3389/fnsys.2023.1213279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 08/21/2023] [Indexed: 10/10/2023] Open
Abstract
The precise control of bite force and gape is vital for safe and effective breakdown and manipulation of food inside the oral cavity during feeding. Yet, the role of the orofacial sensorimotor cortex (OSMcx) in the control of bite force and gape is still largely unknown. The aim of this study was to elucidate how individual neurons and populations of neurons in multiple regions of OSMcx differentially encode bite force and static gape when subjects (Macaca mulatta) generated different levels of bite force at varying gapes. We examined neuronal activity recorded simultaneously from three microelectrode arrays implanted chronically in the primary motor (MIo), primary somatosensory (SIo), and cortical masticatory (CMA) areas of OSMcx. We used generalized linear models to evaluate encoding properties of individual neurons and utilized dimensionality reduction techniques to decompose population activity into components related to specific task parameters. Individual neurons encoded bite force more strongly than gape in all three OSMCx areas although bite force was a better predictor of spiking activity in MIo vs. SIo. Population activity differentiated between levels of bite force and gape while preserving task-independent temporal modulation across the behavioral trial. While activation patterns of neuronal populations were comparable across OSMCx areas, the total variance explained by task parameters was context-dependent and differed across areas. These findings suggest that the cortical control of static gape during biting may rely on computations at the population level whereas the strong encoding of bite force at the individual neuron level allows for the precise and rapid control of bite force.
Collapse
|
47
|
Martakis K, Alexy U, Stark C, Hahn A, Rawer R, Duran I, Schönau E. Jumping Mechanography: Reference Centiles in Childhood and Introduction of the Nerve-Muscle Index to Quantify Motor Efficiency. J Clin Med 2023; 12:5984. [PMID: 37762925 PMCID: PMC10531761 DOI: 10.3390/jcm12185984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/06/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023] Open
Abstract
Jumping mechanography provides robust motor function indicators among children. The study aim was to develop centiles for the single 2-leg jump (S2LJ) in German children and adolescents and to identify differences in children with obesity. Data were collected in 2004-2021 through the German DOrtmund Nutritional and Anthropometric Longitudinally Designed (DONALD) study. All participants (6-18 years, mean age 11.4) performed annually an S2LJ aiming for maximum height on a Ground Reaction Force Platform. LMS (lambda-mu-sigma), including resampling, was used to develop centiles for velocity (vmax), jump height (hmax), relative force (Fmax/BW), relative power (Pmax/mass), impulse asymmetry and a new parameter to describe jump efficiency, the Nerve-Muscle Index (NMI), defined as vmax/(Fmax/BW). Data from 882 children and adolescents were analyzed (3062 measurements, median 3 per individual). In females, Fmax/BW values were higher in younger age but remained constant in adolescence. vmax, hmax and Pmax/mass increased in childhood, reaching a plateau in adolescence. In males, vmax, hmax and Pmax/mass showed a constant increase and the Fmax/BW remained lower. Children with obesity showed lower Fmax/BW, hmax, vmax and the NMI, hence, lower velocity per relative force unit and less efficient jump. The centiles should be used to monitor motor development in childhood. The NMI is a surrogate for motor efficiency.
Collapse
|
48
|
Morgan DM, Spainhower KB, Mossor AM, Avey‐Arroyo JA, Butcher M. Muscle architectural properties indicate a primary role in support for the pelvic limb of three-toed sloths (Bradypus variegatus). J Anat 2023; 243:448-466. [PMID: 37190673 PMCID: PMC10439369 DOI: 10.1111/joa.13884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 04/21/2023] [Accepted: 04/27/2023] [Indexed: 05/17/2023] Open
Abstract
Tree sloths evolved below-branch locomotion making them one of few mammalian taxa beyond primates for which suspension is nearly obligatory. Suspension requires strong limb flexor muscles that provide both propulsion and braking/support, and available locomotor kinetics data indicate that these roles differ between fore- and hindlimb pairs. Muscle structure in the pelvic limb is hypothesized to be a key anatomical correlate of function in braking/support during suspensory walking and propulsion and/or support during vertical climbing. This expectation was tested by quantifying architecture properties in the hindlimb limb musculature of brown-throated three-toed sloths (Bradypus variegatus: N = 7) to distinguish the roles of the flexor/extensor functional muscle groups at each joint. Measurements of muscle moment arm (rm ), mass, belly length, fascicle length, pennation angle, and physiological cross-sectional area (PCSA) were taken from n = 45 muscles. Overall, most muscles studied show properties for contractile excursion and fast joint rotational velocity. However, the flexor musculature is more massive (p = 0.048) and has larger PCSA (p = 0.003) than the extensors, especially at the knee joint and digits where well-developed and strong flexors are capable of applying large joint torque. Moreover, selected hip flexors/extensors and knee flexors have modified long rm that can amplify applied joint torque in muscles with otherwise long, parallel fascicles, and one muscle (m. iliopsoas) was capable of moderately high power in B. variegatus. The architectural properties observed in the hip flexors and extensors match well with roles in suspensory braking and vertical propulsion, respectively, whereas strong knee flexors and digital flexors appear to be the main muscles providing suspensory support in the pelvic limb. With aid in support by the forelimbs and the use of adaptive slow locomotion and slow muscle fiber recruitment patterns, structure-function in the tensile limb systems of sloths appears to collectively represent an additional mechanism for energy conservation.
Collapse
|
49
|
Olds M, McLaine S, Magni N. Validity and Reliability of the Kinvent Handheld Dynamometer in the Athletic Shoulder Test. J Sport Rehabil 2023; 32:764-772. [PMID: 37290770 DOI: 10.1123/jsr.2022-0444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 04/05/2023] [Accepted: 04/16/2023] [Indexed: 06/10/2023]
Abstract
CONTEXT Long-lever shoulder strength tests may aid clinical decision-making regarding return to sport after a shoulder injury. The Athletic Shoulder Test (AST) was developed to measure force production in 3 positions of shoulder abduction (90°, 135°, and 180°) using force plates. However, handheld dynamometers (HHDs) are more portable, affordable, and may provide valid and reliable results which would increase the clinical utility of long-lever tests. HHDs vary in shape, design, and their capacity to report parameters such as rate of force production and require further investigation. The aim of this study was to examine the intrarater reliability of the Kinvent HHD and assess its validity against Kinvent force plates in the AST. Peak force (in kilograms), torque (in Newton meters), and normalized torque (in Newton meters per kilogram) were reported. DESIGN Validity and reliability study. METHODS Twenty-seven participants with no history of upper limb injury performed the test in a randomized order using the Kinvent HHD and force plates. Each condition was assessed 3 times, and peak force was recorded. Arm length was measured to calculate peak torque. Normalized peak torque was calculated by dividing torque by bodyweight (in kilograms). RESULTS The Kinvent HHD is reliable when measuring force (intraclass correlation coefficient [ICC] ≥ .80), torque (ICC ≥ .84), and normalized torque (ICC ≥ .64) during the AST. The Kinvent HHD is also valid when compared with the Kinvent force plates for force (ICC ≥ .79; r ≥ .82), torque (ICC ≥ .82; r ≥ .76), and normalized torque (ICC ≥ .71; r ≥ .61). There were no statistically significant differences across the 3 trials on analyses of variance (P > .05). CONCLUSIONS The Kinvent HHD is a reliable tool when used to measure force, torque, and normalized torque in the AST. Furthermore, given the lack of significant difference between trials, clinicians can use one test to accurately report relative peak force/torque/normalized torque rather than average 3 separate trials. Finally, the Kinvent HHD is valid when compared with Kinvent force plates.
Collapse
|
50
|
González-García J, Aguilar-Navarro M, Giráldez-Costas V, Romero-Moraleda B. Time Course of Jump Recovery and Performance After Velocity-Based Priming and Concurrent Caffeine Intake. RESEARCH QUARTERLY FOR EXERCISE AND SPORT 2023; 94:655-667. [PMID: 35442175 DOI: 10.1080/02701367.2022.2041162] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 02/06/2022] [Indexed: 06/14/2023]
Abstract
Purpose: Morning priming exercise and caffeine intake have been previously suggested as an effective strategy to increase within-day performance and readiness. However, the concurrent effect of both strategies is unknown. The present research aimed to map the within-day time course of recovery and performance of countermovement jump (CMJ) outcomes, kinetics, and strategy and readiness after priming alone and in combination with caffeine. Methods: Eleven participants performed a control, a priming exercise (Priming) and a priming with concurrent caffeine intake (PrimingCaf) in a double-blind randomized, crossover design. CMJ metrics were assessed before, post, and 2 h, 4 h, and 6 h after each condition while readiness was assessed at 6 h. Results: Perceived physical, mental performance capability and activation balance were higher at 6 h after Priming and PrimingCaf conditions. Immediate reductions in jump height (5.45 to 6.25%; p < .046), concentric peak velocity (2.40 to 2.59%; p < .041) and reactive strength index-modified (RSImod) (9.06 to 9.23% p < .051) after Priming and PrimingCaf were observed, being recovered at 2 h (p > .99). Concentric impulse was restored in PrimingCaf (p > .754; d = -0.03 to-0.08) despite lower concentric mean force/BM (p < .662; d = -0.18 to -0.26) as concentric duration was increased (p > .513; d = 0.15 to 0.21). Individual analysis revealed that some participants benefit from both strategies as they showed increases in jump height over the smallest worthwhile change while others did not. Conclusions: Psychological readiness was increased after both priming conditions at 6 h; however, it seems necessary to consider individual changes to achieve the positive effects of the priming or the priming in combination with caffeine on jumping outcomes.
Collapse
|