26
|
Dong Y, Iammarino M, Liu J, Codling J, Fagert J, Mirshekari M, Lowes L, Zhang P, Noh HY. Ambient floor vibration sensing advances the accessibility of functional gait assessments for children with muscular dystrophies. Sci Rep 2024; 14:10774. [PMID: 38729999 PMCID: PMC11087496 DOI: 10.1038/s41598-024-60034-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 04/18/2024] [Indexed: 05/12/2024] Open
Abstract
Muscular dystrophies (MD) are a group of genetic neuromuscular disorders that cause progressive weakness and loss of muscles over time, influencing 1 in 3500-5000 children worldwide. New and exciting treatment options have led to a critical need for a clinical post-marketing surveillance tool to confirm the efficacy and safety of these treatments after individuals receive them in a commercial setting. For MDs, functional gait assessment is a common approach to evaluate the efficacy of the treatments because muscle weakness is reflected in individuals' walking patterns. However, there is little incentive for the family to continue to travel for such assessments due to the lack of access to specialty centers. While various existing sensing devices, such as cameras, force plates, and wearables can assess gait at home, they are limited by privacy concerns, area of coverage, and discomfort in carrying devices, which is not practical for long-term, continuous monitoring in daily settings. In this study, we introduce a novel functional gait assessment system using ambient floor vibrations, which is non-invasive and scalable, requiring only low-cost and sparsely deployed geophone sensors attached to the floor surface, suitable for in-home usage. Our system captures floor vibrations generated by footsteps from patients while they walk around and analyzes such vibrations to extract essential gait health information. To enhance interpretability and reliability under various sensing scenarios, we translate the signal patterns of floor vibration to pathological gait patterns related to MD, and develop a hierarchical learning algorithm that aggregates insights from individual footsteps to estimate a person's overall gait performance. When evaluated through real-world experiments with 36 subjects (including 15 patients with MD), our floor vibration sensing system achieves a 94.8% accuracy in predicting functional gait stages for patients with MD. Our approach enables accurate, accessible, and scalable functional gait assessment, bringing MD progressive tracking into real life.
Collapse
|
27
|
Jiang Q, Yin Z, Yin H, Ma R, Lin W. Seismic performance of soft soil foundation with a new type of assembled wall tuned mass damper. PLoS One 2024; 19:e0298263. [PMID: 38722883 PMCID: PMC11081288 DOI: 10.1371/journal.pone.0298263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 01/22/2024] [Indexed: 05/13/2024] Open
Abstract
The design of tuned mass damper (TMD) parameters is influenced by the soil-structure-TMD coupling system; thus, it is important to consider the soil-structure interaction (SSI) for the vibration control effect of the TMD. Recently, the acquisition of TMD parameters considering soil-structure interactions has only remained at the theoretical stage, lacking relevant experimental verification. Traditional TMD face the problems of occupying a large building space, increasing construction costs, and non-replaceable components. In this study, an assembled wall-type damping TMD was designed. By comparing the dynamic response of the uncontrolled and controlled structures equipped with the newly assembled wall-type damping TMD in the shaking table test on a soft soil foundation, we analyzed whether the SSI effect was considered in the TMD design parameters on the damping effect of the newly assembled wall-type tuned mass damper. The TMD parameters optimized using the artificial intelligence algorithm were verified experimentally. The results indicated that the traditional TMD design parameters were discordant because the SSI effect was not considered. The SSI effect in the soil effectively reduces the dynamic response of the superstructure. By considering the SSI effect and improving the multi-population genetic algorithm, a wall-type damping TMD with optimized parameters can achieve a good damping effect.
Collapse
|
28
|
Zhu Q, Xiao Q. Dynamics of seaweed-inspired piezoelectric plates for energy harvesting from oscillatory cross flow. BIOINSPIRATION & BIOMIMETICS 2024; 19:046004. [PMID: 38663427 DOI: 10.1088/1748-3190/ad43d1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 04/25/2024] [Indexed: 05/09/2024]
Abstract
Inspired by the vibrations of aquatic plants such as seaweed in the unsteady flow fields generated by free-surface waves, we investigate a novel device based on piezoelectric plates to harvest energy from oscillatory cross flows. Towards this end, numerical studies are conducted using a flow-structure-electric interaction model to understand the underlying physical mechanisms involved in the dynamics and energy harvesting performance of one or a pair of piezoelectric plates in an oscillatory cross flow. In a single-plate configuration, both periodic and irregular responses have been observed depending on parameters such as normalized plate stiffness and Keulegan-Carpenter number. Large power harvesting is achieved with the excitation of natural modes. Besides, when the time scale of the motion and the intrinsic time scale of the circuit are close to each other the power extraction is enhanced. In a two-plate configuration with tandem formation, the hydrodynamic interaction between the two plates can induce irregularity in the response. In terms of energy harvesting, two counteracting mechanisms have been identified, shielding and energy recovery. The shielding effect reduces plate motion and energy harvesting, whereas with the energy recovery effect one plate is able to recovery energy from the wake of another for performance enhancement. The competition between these mechanisms leads to constructive or destructive interactions between the two plates. These results suggest that for better performance the system should be excited at its natural period, which should be close to the intrinsic time scale of the circuit. Moreover, using a pair of plates in a tandem formation can further improve the energy harvesting capacity when conditions for constructive interaction are satisfied.
Collapse
|
29
|
Cha J, Kim C, Choi SH. Extrinsic Laryngeal Muscle Activity With Different Diameters and Water Depths in a Semi-Occluded Vocal Tract Exercise. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2024; 67:1324-1338. [PMID: 38592964 DOI: 10.1044/2024_jslhr-23-00194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
PURPOSE Surface electromyography (sEMG) has been used to evaluate extrinsic laryngeal muscle activity during swallowing and phonation. In the current study, sEMG amplitudes were measured from the infrahyoid and suprahyoid muscles during phonation through a tube submerged in water. METHOD The sEMG amplitude values measured from the extrinsic laryngeal muscles and the electroglottographic contact quotient (CQ) were obtained simultaneously from 62 healthy participants (31 men, 31 women) during phonation through a tube at six different depths (2, 4, 7, 10, 15, and 20 cm) while using two tubes with different diameters (1 and 0.5 cm). RESULTS With increasing depth, the sEMG amplitude for the suprahyoid muscles increased in men and women. However, sEMG amplitudes for the infrahyoid muscles increased significantly only in men. Tube diameter had a significant effect on the suprahyoid sEMG amplitudes only for men, with higher sEMG amplitudes when phonating with a 1.0-cm tube. CQ values increased with submerged depth for both men and women. Tube diameter affected results such than CQ values were higher for men when using the wider tube and for women with the narrower tube. CONCLUSIONS Vocal fold vibratory patterns changed with the depth of tube submersion in water for both men and women, but the patterns of muscle activation differed between the sexes. This suggests that men and women use different strategies when confronted with increased intraoral pressure during semi-occluded vocal tract exercises. In this study, sEMG provided insight into the mechanism for differences between vocally normal individuals and could help detect compensatory muscle activation during tube phonation in water for people with voice disorders.
Collapse
|
30
|
Tanabe T, Kaneko H. Illusory Directional Sensation Induced by Asymmetric Vibrations Influences Sense of Agency and Velocity in Wrist Motions. IEEE Trans Neural Syst Rehabil Eng 2024; 32:1749-1756. [PMID: 38656862 DOI: 10.1109/tnsre.2024.3393434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
Illusory directional sensations are generated through asymmetric vibrations applied to the fingertips and have been utilized to induce upper-limb motions in the rehabilitation and training of patients with visual impairment. However, its effects on motor control remain unclear. This study aimed to verify the effects of illusory directional sensations on wrist motion. We conducted objective and subjective evaluations of wrist motion during a motor task, while inducing an illusory directional sensation that was congruent or incongruent with wrist motion. We found that, when motion and illusory directional sensations were congruent, the sense of agency for motion decreased. This indicates an induction sensation of the hand being moved by the illusion. Interestingly, although no physical force was applied to the hand, the angular velocity of the wrist was higher in the congruent condition than that in the no-stimulation condition. The angular velocity of the wrist and electromyography signals of the agonist muscles were weakly positively correlated, suggesting that the participants may have increased their wrist velocity. In other words, the congruence between the direction of motion and illusory directional sensation induced the sensation of the hand being moved, even though the participants' wrist-motion velocity increased. This phenomenon can be explained by the discrepancy between the sensation of active motion predicted by the efferent copy, and that of actual motion caused by the addition of the illusion. The findings of this study can guide the design of novel rehabilitation methods.
Collapse
|
31
|
Baker CP, Sundberg J, Purdy SC, Rakena TO, Leão SHDS. CPPS and Voice-Source Parameters: Objective Analysis of the Singing Voice. J Voice 2024; 38:549-560. [PMID: 35000836 DOI: 10.1016/j.jvoice.2021.12.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 12/08/2021] [Accepted: 12/13/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION In recent years cepstral analysis and specific cepstrum-based measures such as smoothed cepstral peak prominence (CPPS) has become increasingly researched and utilized in attempts to determine the extent of overall dysphonia in voice signals. Yet, few studies have extensively examined how specific voice-source parameters affect CPPS values. OBJECTIVE Using a range of synthesized tones, this exploratory study sought to systematically analyze the effect of fundamental frequency (fo), vibrato extent, source-spectrum tilt, and the amplitude of the voice-source fundamental on CPPS values. MATERIALS AND METHODS A series of scales were synthesised using the freeware Madde. Fundamental frequency, vibrato extent, source-spectrum tilt, and the amplitude of the voice-source fundamental were systematically and independently varied. The tones were analysed in PRAAT, and statistical analyses were conducted in SPSS. RESULTS CPPS was significantly affected by both fo and source-spectrum tilt, independently. A nonlinear association was seen between vibrato extent and CPPS, where CPPS values increased from 0 to 0.6 semitones (ST), then rapidly decreased approaching 1.0 ST. No relationship was seen between the amplitude of the voice-source fundamental and CPPS. CONCLUSION The large effect of fo should be taken into account when analyzing the voice, particularly in singing-voice research, when comparing pre and posttreatment data, and when comparing inter-subject CPPS data.
Collapse
|
32
|
Taylor JM, Conboy JC. Sum-frequency vibrational spectroscopy, a tutorial: Applications for the study of lipid membrane structure and dynamics. Biointerphases 2024; 19:031201. [PMID: 38738942 DOI: 10.1116/6.0003594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Accepted: 04/23/2024] [Indexed: 05/14/2024] Open
Abstract
Planar supported lipid bilayers (PSLBs) are an ideal model for the study of lipid membrane structures and dynamics when using sum-frequency vibrational spectroscopy (SFVS). In this paper, we describe the construction of asymmetric PSLBs and the basic SFVS theory needed to understand and make measurements on these membranes. Several examples are presented, including the determination of phospholipid orientation and measuring phospholipid transmembrane translocation (flip-flop).
Collapse
|
33
|
Uchima PV, Idehara SJ. Assessing patient transport conditions during ambulance transit. Proc Inst Mech Eng H 2024; 238:508-519. [PMID: 38562010 DOI: 10.1177/09544119241240908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Emergency ambulances play a vital role in medical rescue and patient transportation, but their transit can impact patient health due to vehicle dynamic forces and vibrations. This study evaluates patient transport conditions on a stretcher subjected to vertical vibration excitation from road unevenness. Using an eight-degree-of-freedom numerical model, we analyze the construction parameters of a medical stretcher's support and vehicle suspension. Actual experimental data from an emergency vehicle were utilized to assess the vibration conditions experienced by both the stretcher and the ambulance floor. The model is adjusted based on measurements, specifically targeting the main vibration modes. The investigation involves determining temporal responses for vertical accelerations and characterizing vibration modal parameters under various transportation conditions. Notably, several system natural frequencies fall within the range of human body frequencies, making them susceptible to mechanical excitation, particularly in the human neck, abdomen, and spine. A sensitivity analysis underscores the influence of medical stretcher support structure parameters on patient comfort. Increasing support stiffness, which alters the stretcher's natural frequency, and damping coefficient reduce vibration propagation between the vehicle and the patient. Additionally, the research predicts the model's dynamic behavior on roads with low-quality pavement, indicating vibrational amplitudes that could potentially be discomforting and unhealthy for individuals. The study illustrates a vibration exposure period on a class E road, revealing that transportation longer than 25 min may cause damage to patient health.
Collapse
|
34
|
Arshad T, Vainer D, Khan H, Baral A, Garg S, Ang A, Patel V, Kumaran V, Bruno D, Lee S, Sharma A, Muthiah M, Bui AT, Siddiqui MS. Development of Clinical Algorithm Utilizing Vibration-Controlled Transient Elastography to Detect Advanced Hepatic Fibrosis in Liver Transplant Recipients. Dig Dis Sci 2024; 69:1844-1851. [PMID: 38499735 PMCID: PMC11098731 DOI: 10.1007/s10620-024-08366-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Accepted: 02/20/2024] [Indexed: 03/20/2024]
Abstract
INTRODUCTION Vibration-controlled transient elastography (VCTE) based liver stiffness measurement (LSM) is an excellent 'rule-out' test for advanced hepatic fibrosis in liver transplant (LT) recipients, however, its ability to 'rule-in' the disease is suboptimal. The study aimed to improve diagnostic performance of LSM in LT recipients. METHODS Adult LT recipients with a liver biopsy and VCTE were included (N = 150). Sequential covering analysis was performed to create rules to identify patients at low or high risk for advanced fibrosis (stage 3-4). RESULTS Advanced hepatic fibrosis was excluded in patients with either LSM < 7.45 kPa (n = 72) or 7.45 ≤ LSM < 12.1 kPa and time from LT < 5.6 years (n = 25). Conversely, likelihood of advanced fibrosis was 95% if patients had LSM > 14.1 and controlled attenuation parameter > 279 dB/m (n = 21). Thus, 118 (79%) were correctly identified and 32 (21%) would have required a biopsy to establish the diagnosis. Compared to previously established LSM based cutoff values of 10.5 kPa (Youden index) and 13.3 kPa (maximized specificity), the false positive rates of sequential covering analysis was 1% compared to 16.5% with LSM ≥ 10.5 kPa and 8.3% with LSM ≥ 13.3 kPa. The true positive rates were comparable at 87% for sequential covering analysis, 93% for LSM ≥ 10.5 kPa and 83% for LSM ≥ 13.3 kPa. CONCLUSION The proposed clinical sequential covering analysis allows for better risk stratification when evaluating for advanced fibrosis in LT recipients compared to LSM alone. Additional efforts are necessary to further reduce the number of patients with indeterminate results in whom a liver biopsy may be required.
Collapse
|
35
|
Matsumoto T, Kanaya M, Matsushima D, Han C, Tokuda IT. Synchronized and Desynchronized Dynamics Observed from Physical Models of the Vocal and Ventricular Folds. J Voice 2024; 38:572-584. [PMID: 34903395 DOI: 10.1016/j.jvoice.2021.10.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 10/25/2021] [Accepted: 10/28/2021] [Indexed: 11/16/2022]
Abstract
The ventricular folds, located superiorly to the vocal folds, do not usually vibrate during normal phonations. It has been shown, however, that they do vibrate together with the vocal folds under special circumstances such as voice pathology and singing voice. Towards understanding the effect of the ventricular fold oscillations on the vocal fold oscillations, the present study developed a synthetic model that takes into account anatomical features of the human ventricular folds. The synthetic model is made of flexible silicone compounds with material properties comparable to those of human ventricular fold tissues. In our experiment, an air-flow was injected into the vocal and ventricular fold models. As the distance between the left and right ventricular folds was reduced, the ventricular folds started to co-vibrate with the vocal folds. Depending upon the distance, various oscillation patterns of the vocal-ventricular folds were observed, e.g., synchronized dynamics with 1:1 or 1:2 frequency ratio and desynchronized chaotic dynamics. The observed chaotic dynamics might be related to voice pathology induced by the ventricular phonation. A computational model was further presented to elucidate the experimental findings.
Collapse
|
36
|
Ebrahimian A, Mohammadi H, Maftoon N. Material characterization of human middle ear using machine-learning-based surrogate models. J Mech Behav Biomed Mater 2024; 153:106478. [PMID: 38493562 DOI: 10.1016/j.jmbbm.2024.106478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 02/09/2024] [Accepted: 02/24/2024] [Indexed: 03/19/2024]
Abstract
This study aims to introduce a novel non-invasive method for rapid material characterization of middle-ear structures, taking into consideration the invaluable insights provided by the mechanical properties of ear tissues. Valuable insights into various ear pathologies can be gleaned from the mechanical properties of ear tissues, yet conventional techniques for assessing these properties often entail invasive procedures that preclude their use on living patients. In this study, in the first step, we developed machine-learning models of the middle ear to predict its responses with a significantly lower computational cost in comparison to finite-element models. Leveraging findings from prior research, we focused on the most influential model parameters: the Young's modulus and thickness of the tympanic membrane and the Young's modulus of the stapedial annular ligament. The eXtreme Gradient Boosting (XGBoost) method was implemented for creating the machine-learning models. Subsequently, we combined the created machine-learning models with Bayesian optimization (BoTorch) for fast and efficient estimation of the Young's moduli of the tympanic membrane and the stapedial annular ligament. We demonstrate that the resultant surrogate models can fairly represent the vibrational responses of the umbo, stapes footplate, and vibration patterns of the tympanic membrane at most frequencies. Also, our proposed material characterization approach successfully estimated the Young's moduli of the tympanic membrane and stapedial annular ligament (separately and simultaneously) with values of mean absolute percentage error of less than 7%. The remarkable accuracy achieved through the proposed material characterization method underscores its potential for eventual clinical applications of estimating mechanical properties of the middle-ear structures for diagnostic purposes.
Collapse
|
37
|
Yang L, Yue S, Tao Y, Qiao S, Li H, Dai Z, Song B, Chen Y, Du J, Li D, Gao P. Suppressed thermal transport in silicon nanoribbons by inhomogeneous strain. Nature 2024; 629:1021-1026. [PMID: 38750362 DOI: 10.1038/s41586-024-07390-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 04/05/2024] [Indexed: 05/31/2024]
Abstract
Nanoscale structures can produce extreme strain that enables unprecedented material properties, such as tailored electronic bandgap1-5, elevated superconducting temperature6,7 and enhanced electrocatalytic activity8,9. While uniform strains are known to elicit limited effects on heat flow10-15, the impact of inhomogeneous strains has remained elusive owing to the coexistence of interfaces16-20 and defects21-23. Here we address this gap by introducing inhomogeneous strain through bending individual silicon nanoribbons on a custom-fabricated microdevice and measuring its effect on thermal transport while characterizing the strain-dependent vibrational spectra with sub-nanometre resolution. Our results show that a strain gradient of 0.112% per nanometre could lead to a drastic thermal conductivity reduction of 34 ± 5%, in clear contrast to the nearly constant values measured under uniform strains10,12,14,15. We further map the local lattice vibrational spectra using electron energy-loss spectroscopy, which reveals phonon peak shifts of several millielectron-volts along the strain gradient. This unique phonon spectra broadening effect intensifies phonon scattering and substantially impedes thermal transport, as evidenced by first-principles calculations. Our work uncovers a crucial piece of the long-standing puzzle of lattice dynamics under inhomogeneous strain, which is absent under uniform strain and eludes conventional understanding.
Collapse
|
38
|
Peacock J, Spellman GM, Field DJ, Mason MJ, Mayr G. Comparative morphology of the avian bony columella. Anat Rec (Hoboken) 2024; 307:1735-1763. [PMID: 37365751 DOI: 10.1002/ar.25278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 06/01/2023] [Accepted: 06/04/2023] [Indexed: 06/28/2023]
Abstract
In birds, the columella is the only bony element of the sound conducting apparatus, conveying vibrations of the cartilaginous extracolumella to the fluid of the inner ear. Although avian columellar morphology has attracted some attention over the past century, it nonetheless remains poorly described in the literature. The few existing studies mostly focus on morphological descriptions in relatively few taxa, with no taxonomically broad surveys yet published. Here we use observations of columellae from 401 extant bird species to provide a comprehensive survey of columellar morphology in a phylogenetic context. We describe the columellae of several taxa for the first time and identify derived morphologies characterizing higher-level clades based on current phylogenies. In particular, we identify a derived columellar morphology diagnosing a major subclade of Accipitridae. Within Suliformes, we find that Fregatidae, Sulidae, and Phalacrocoracidae share a derived morphology that is absent in Anhingidae, suggesting a secondary reversal. Phylogenetically informed comparisons allow recognition of instances of homoplasy, including the distinctive bulbous columellae in suboscine passerines and taxa belonging to Eucavitaves, and bulging footplates that appear to have evolved at least twice independently in Strigiformes. We consider phylogenetic and functional factors influencing avian columellar morphology, finding that aquatic birds possess small footplates relative to columellar length, possibly related to hearing function in aquatic habitats. By contrast, the functional significance of the distinctive bulbous basal ends of the columellae of certain arboreal landbird taxa remains elusive.
Collapse
|
39
|
Pagán OR. The complexities of ligand/receptor interactions: Exploring the role of molecular vibrations and quantum tunnelling. Bioessays 2024; 46:e2300195. [PMID: 38459808 DOI: 10.1002/bies.202300195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 01/19/2024] [Accepted: 02/19/2024] [Indexed: 03/10/2024]
Abstract
Molecular vibrations and quantum tunneling may link ligand binding to the function of pharmacological receptors. The well-established lock-and-key model explains a ligand's binding and recognition by a receptor; however, a general mechanism by which receptors translate binding into activation, inactivation, or modulation remains elusive. The Vibration Theory of Olfaction was proposed in the 1930s to explain this subset of receptor-mediated phenomena by correlating odorant molecular vibrations to smell, but a mechanism was lacking. In the 1990s, inelastic electron tunneling was proposed as a plausible mechanism for translating molecular vibration to odorant physiology. More recently, studies of ligands' vibrational spectra and the use of deuterated ligand analogs have provided helpful information to study this admittedly controversial hypothesis in metabotropic receptors other than olfactory receptors. In the present work, based in part on published experiments from our laboratory using planarians as an experimental organism, I will present a rationale and possible experimental approach for extending this idea to ligand-gated ion channels.
Collapse
|
40
|
Gustafsson JK, Södersten M, Ternström S, Schalling E. Treatment of Hypophonia in Parkinson's Disease Through Biofeedback in Daily Life Administered with A Portable Voice Accumulator. J Voice 2024; 38:800.e27-800.e38. [PMID: 34893384 DOI: 10.1016/j.jvoice.2021.10.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 10/06/2021] [Accepted: 10/10/2021] [Indexed: 11/18/2022]
Abstract
OBJECTIVES The purpose of this study was to assess the outcome following continuous tactile biofeedback of voice sound level administered, with a portable voice accumulator to individuals with Parkinson's disease (PD). METHOD Nine out of 16 participants with PD completed a 4-week intervention program where biofeedback of voice sound level was administered with the portable voice accumulator VoxLog during speech in daily life. The feedback, a tactile vibration signal from the device, was activated when the wearer used a voice sound level below an individually predetermined threshold level, reminding the wearer to increase voice sound level during speech. Voice use was registered in daily life with the VoxLog during the intervention period as well as during one baseline week, one follow-up week post intervention and 1 week 3 months post intervention. Self-to-other ratio (SOR), which is the difference between voice sound level and environmental noise, was studied in multiple noise ranges. RESULTS A significant increase in SOR across all noise ranges of 2.28 dB (SD: 0.55) was seen for participants with scores above the cut-off for normal function (>26 points) on the cognitive screening test Montreal Cognitive Assessment (MoCA) (n = 5). No significant increase was seen for the group of participants with MoCA scores below 26 (n = 4). Forty-four percent ended their participation early, all which scored below 26 on MoCA (n = 7). CONCLUSIONS Biofeedback administered in daily life regarding voice level may help individuals with PD to increase their voice sound level in relation to environmental noise in daily life, but only for a limited subset. Only participants with normal cognitive function as screened by MoCA improved their voice sound level in relation to environmental noise.
Collapse
|
41
|
Condon S, Hu H, Kong M, Cave MC, McClain CJ. ALT poorly predicts Nonalcoholic Fatty Liver Disease (NAFLD) and liver fibrosis as determined by vibration-controlled transient elastography in adult National Health and Nutrition Examination Survey 2017-2018. Am J Med Sci 2024; 367:310-322. [PMID: 38307172 DOI: 10.1016/j.amjms.2024.01.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 01/24/2024] [Accepted: 01/25/2024] [Indexed: 02/04/2024]
Abstract
BACKGROUND Non-alcoholic fatty liver disease is a growing problem in the United States, contributing to a range of liver disease as well as cardiovascular disease. ALT is the most widely used liver chemistry for NAFLD evaluation. We hypothesized that the normal range many laboratories use was too high, missing many patients with clinically important steatosis and/or fibrosis. METHODS This study utilized 2017-2018 NHANES data including 9254 participants. We compared four different upper limits of normal for ALT with specific measurements of steatosis and liver stiffness as determined by liver elastography with FibroScan®. Liver stiffness was further characterized as showing any fibrosis or advanced fibrosis. After exclusions, our final pool was 4184 for liver stiffness measurement and 4183 for steatosis grade as measured by Controlled Attenuation Parameter (CAP). Using these variables, we performed logistic regression between ALT and CAP, and ALT and fibrosis/advanced fibrosis, and did a Receiver Operating Characteristic curve. RESULTS Based on three of the most widely used cut off values for ALT, we found that ALT does not reliably rule out NAFLD in over 50% of cases. It also missed 45.9-64.2% of patients with liver fibrosis. CONCLUSIONS Our study revealed that ALT is an inaccurate marker for NAFLD as measured by FibroScan® with CAP greater than or equal to 300 dB/m. Accuracy improved specific risk factors were considered. These data also showed that ALT was a poor marker for liver fibrosis. We conclude that there is no single ALT level that accurately predicts hepatic steatosis or fibrosis.
Collapse
|
42
|
Ouakka S, Verlinden O, Kouroussis G. Forests as natural metamaterial barriers for urban railway-induced vibration attenuation. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 358:120686. [PMID: 38599078 DOI: 10.1016/j.jenvman.2024.120686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 03/01/2024] [Accepted: 03/16/2024] [Indexed: 04/12/2024]
Abstract
Noise and vibrations generated by railway traffic can seriously affect the adjacent buildings and their residents. Different mitigation methods have been proposed in the past decades to tackle this challenge. Despite many mitigation measures presented in the literature, some of these measures have shown limitations in their application, while for others their carbon footprint does not justify their implementation in real projects. This study introduces the concept of forests as natural metamaterials to attenuate the vibrations generated at the wheel-rail interaction. In particular, a group of natural metamaterials, in the form of a forest, is introduced into a vehicle/track/soil validated model based on the two-step approach. The ideal tree/soil unit-cell constituting the forest is obtained through a parametric investigation of the geometrical and material properties in order to have the first band-gap within the main range of frequencies generated by railway traffic in urban areas. The vibration attenuation levels obtained by the introduction of the natural metamaterial are then evaluated by considering a range of operational velocities for the T2000 Brussels tram LRV (Light Rail Vehicle). Finally, some insights on the attenuation efficiency of the selected forest towards vibrations generated by HSTs (High-Speed Trains) are given by considering a mono-wheel model with a higher range of vehicle speeds.
Collapse
|
43
|
Jouybari AF, Ferraroli N, Bouri M, Alaoui SH, Kannape OA, Blanke O. Augmenting locomotor perception by remapping tactile foot sensation to the back. J Neuroeng Rehabil 2024; 21:65. [PMID: 38678291 PMCID: PMC11055306 DOI: 10.1186/s12984-024-01344-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 03/19/2024] [Indexed: 04/29/2024] Open
Abstract
BACKGROUND Sensory reafferents are crucial to correct our posture and movements, both reflexively and in a cognitively driven manner. They are also integral to developing and maintaining a sense of agency for our actions. In cases of compromised reafferents, such as for persons with amputated or congenitally missing limbs, or diseases of the peripheral and central nervous systems, augmented sensory feedback therefore has the potential for a strong, neurorehabilitative impact. We here developed an untethered vibrotactile garment that provides walking-related sensory feedback remapped non-invasively to the wearer's back. Using the so-called FeetBack system, we investigated if healthy individuals perceive synchronous remapped feedback as corresponding to their own movement (motor awareness) and how temporal delays in tactile locomotor feedback affect both motor awareness and walking characteristics (adaptation). METHODS We designed the system to remap somatosensory information from the foot-soles of healthy participants (N = 29), using vibrotactile apparent movement, to two linear arrays of vibrators mounted ipsilaterally on the back. This mimics the translation of the centre-of-mass over each foot during stance-phase. The intervention included trials with real-time or delayed feedback, resulting in a total of 120 trials and approximately 750 step-cycles, i.e. 1500 steps, per participant. Based on previous work, experimental delays ranged from 0ms to 1500ms to include up to a full step-cycle (baseline stride-time: µ = 1144 ± 9ms, range 986-1379ms). After each trial participants were asked to report their motor awareness. RESULTS Participants reported high correspondence between their movement and the remapped feedback for real-time trials (85 ± 3%, µ ± σ), and lowest correspondence for trials with left-right reversed feedback (22 ± 6% at 600ms delay). Participants further reported high correspondence of trials delayed by a full gait-cycle (78 ± 4% at 1200ms delay), such that the modulation of motor awareness is best expressed as a sinusoidal relationship reflecting the phase-shifts between actual and remapped tactile feedback (cos model: 38% reduction of residual sum of squares (RSS) compared to linear fit, p < 0.001). The temporal delay systematically but only moderately modulated participant stride-time in a sinusoidal fashion (3% reduction of RSS compared a linear fit, p < 0.01). CONCLUSIONS We here demonstrate that lateralized, remapped haptic feedback modulates motor awareness in a systematic, gait-cycle dependent manner. Based on this approach, the FeetBack system was used to provide augmented sensory information pertinent to the user's on-going movement such that they reported high motor awareness for (re)synchronized feedback of their movements. While motor adaptation was limited in the current cohort of healthy participants, the next step will be to evaluate if individuals with a compromised peripheral nervous system, as well as those with conditions of the central nervous system such as Parkinson's Disease, may benefit from the FeetBack system, both for maintaining a sense of agency over their movements as well as for systematic gait-adaptation in response to the remapped, self-paced, rhythmic feedback.
Collapse
|
44
|
Li K, Suliali NJ, Sahoo PK, Silver CD, Davrandi M, Wright K, Reardon C, Johnson SD, Krauss TF. Noise Tolerant Photonic Bowtie Grating Environmental Sensor. ACS Sens 2024; 9:1857-1865. [PMID: 38597428 PMCID: PMC11059099 DOI: 10.1021/acssensors.3c02419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 02/29/2024] [Accepted: 04/02/2024] [Indexed: 04/11/2024]
Abstract
Resonant photonic refractive index sensors have made major advances based on their high sensitivity and contact-less readout capability, which is advantageous in many areas of science and technology. A major issue for the technological implementation of such sensors is their response to external influences, such as vibrations and temperature variations; the more sensitive a sensor, the more susceptible it also becomes to external influences. Here, we introduce a novel bowtie-shaped sensor that is highly responsive to refractive index variations while compensating for temperature changes and mechanical (linear and angular) vibrations. We exemplify its capability by demonstrating the detection of salinity to a precision of 0.1%, corresponding to 2.3 × 10-4 refractive index units in the presence of temperature fluctuations and mechanical vibrations. As a second exemplar, we detected bacteria growth in a pilot industrial environment. Our results demonstrate that it is possible to translate high sensitivity resonant photonic refractive index sensors into real-world environments.
Collapse
|
45
|
Elmanaseer WR, Alamoush RA, Alsoleihat F, Al-Omiri MK. Position of Fovea Palatinae relative to the vibrating line in various soft palate classifications among Jordanian edentulous population. Sci Rep 2024; 14:9559. [PMID: 38671220 PMCID: PMC11053158 DOI: 10.1038/s41598-024-60162-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Accepted: 04/19/2024] [Indexed: 04/28/2024] Open
Abstract
This study aims to examine the relationship between the locations of Fovea Palatinae and the posterior vibrating line in different classes of soft palate angulation (House Classification), accordingly determine its reliability as a landmark and a tool for determining the posterior limit of the maxillary complete denture. 280 completely edentulous patients with normal healthy mucosa from both genders were randomly selected. The House classification of the soft palate angulation was identified and recorded as Class I, II, or III. Phonation was used to determine the position of the vibrating line. The Fovea Palatinae was then marked. Then, the distance between the Fovea Palatinae and the vibrating line was measured and recorded. Finally, the relative position of the Fovea Palatinae to the vibrating line was recorded as being anterior, posterior, or on the vibrating line. The Chi Square test, the effect size measures (Eta and Cramer's V tests), The Spearman's Rho rank correlation test, and multinominal logistic regression analysis were utilized to analyse the data. House classification percentages were measured among people whose Fovea Palatinae was detectable; Class II palate was the most prevalent (47.14%), followed by Class I (43.93%), and then Class III (8.93%). Based on vibrating line position, 129 (58%) had a vibrating line anterior to Fovea Palatinae, 57 (26%) on the Fovea Palatinae, 36 (16%) posterior to Fovea Palatinae, and in 58 (21%) Fovea Palatinae were not detected. The mean distance between the vibrating line and Fovea Palatinae was 3.66 ± 1.6 mm anteriorly and 2.97 ± 1.36 mm posteriorly. No significant differences were found between males and females in regard to House classification and vibrating line position. The odds of having the fovea posterior to the vibrating line would increase by 5% for each year increase in the age (P = 0.035, odds ratio = 1.050). Class II House classification of the soft palate was found to be the most prevalent among the study participants. Also, the vibrating line was anterior to the Fovea Palatinae in the majority of cases. The odds of having the fovea posterior to the vibrating line would increase by age. The Fovea Palatinae could be considered a useful guide for locating the vibrating line.
Collapse
|
46
|
Awan WA, Islam T, N. Alsunaydih F, Alsaleem F, Alhassoonc K. Dual-band MIMO antenna with low mutual coupling for 2.4/5.8 GHz communication and wearable technologies. PLoS One 2024; 19:e0301924. [PMID: 38630765 PMCID: PMC11023486 DOI: 10.1371/journal.pone.0301924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Accepted: 03/25/2024] [Indexed: 04/19/2024] Open
Abstract
To satisfy the requirements of modern communication systems and wearables using 2.4/5.8 GHz band this paper presents a simple, compact, and dual-band solution. The antenna is extracted from a circular monopole by inserting various patches and stubs. The genetic algorithm is utilized to optimize the parameters and achieve the best possible results regarding bandwidth and gain. Afterward, a 2-port multiple-input-multiple-output (MIMO) configuration is created by positioning an identical second single element perpendicularly to the first one. The electrical size of the suggested MIMO configuration is 0.26 λL × 0.53 λL, where λL represents the free space wavelength at lower resonance of 2.45 GHz. The common ground technique is adopted to further reduce and achieve the accepted level of mutual coupling of the MIMO configuration. The presented MIMO antenna offers a low mutual coupling of < -27 dB with 0.2 envelope correlation coefficient (ECC). The antenna has a gain of around 6.2 dBi and 6.5 dBi at resonating frequencies of 2.45 GHz and 5.4 GHz. Furthermore, the specific absorption rate (SAR) analysis of the MIMO antenna offers a range inside of the standard values, showing its potential for On/Off body communications. The comparison with already published works shows that the proposed antenna achieves better results in either compact size or wide operational bandwidth along with low mutual coupling.
Collapse
|
47
|
Lin H, Lee HW, Yip TCF, Tsochatzis E, Petta S, Bugianesi E, Yoneda M, Zheng MH, Hagström H, Boursier J, Calleja JL, Goh GBB, Chan WK, Gallego-Durán R, Sanyal AJ, de Lédinghen V, Newsome PN, Fan JG, Castéra L, Lai M, Harrison SA, Fournier-Poizat C, Wong GLH, Pennisi G, Armandi A, Nakajima A, Liu WY, Shang Y, de Saint-Loup M, Llop E, Teh KKJ, Lara-Romero C, Asgharpour A, Mahgoub S, Chan MSW, Canivet CM, Romero-Gomez M, Kim SU, Wong VWS. Vibration-Controlled Transient Elastography Scores to Predict Liver-Related Events in Steatotic Liver Disease. JAMA 2024; 331:1287-1297. [PMID: 38512249 PMCID: PMC10958386 DOI: 10.1001/jama.2024.1447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 01/30/2024] [Indexed: 03/22/2024]
Abstract
Importance Metabolic dysfunction-associated steatotic liver disease (MASLD) is currently the most common chronic liver disease worldwide. It is important to develop noninvasive tests to assess the disease severity and prognosis. Objective To study the prognostic implications of baseline levels and dynamic changes of the vibration-controlled transient elastography (VCTE)-based scores developed for the diagnosis of advanced fibrosis (Agile 3+) and cirrhosis (Agile 4) in patients with MASLD. Design, Setting, and Participants This cohort study included data from a natural history cohort of patients with MASLD who underwent VCTE examination at 16 tertiary referral centers in the US, Europe, and Asia from February 2004 to January 2023, of which the data were collected prospectively at 14 centers. Eligible patients were adults aged at least 18 years with hepatic steatosis diagnosed by histologic methods (steatosis in ≥5% of hepatocytes) or imaging studies (ultrasonography, computed tomography or magnetic resonance imaging, or controlled attenuation parameter ≥248 dB/m by VCTE). Main Outcomes and Measures The primary outcome was liver-related events (LREs), defined as hepatocellular carcinoma or hepatic decompensation (ascites, variceal hemorrhage, hepatic encephalopathy, or hepatorenal syndrome), liver transplant, and liver-related deaths. The Agile scores were compared with histologic and 8 other noninvasive tests. Results A total of 16 603 patients underwent VCTE examination at baseline (mean [SD] age, 52.5 [13.7] years; 9600 [57.8%] were male). At a median follow-up of 51.7 (IQR, 25.2-85.2) months, 316 patients (1.9%) developed LREs. Both Agile 3+ and Agile 4 scores classified fewer patients between the low and high cutoffs than most fibrosis scores and achieved the highest discriminatory power in predicting LREs (integrated area under the time-dependent receiver-operating characteristic curve, 0.89). A total of 10 920 patients (65.8%) had repeated VCTE examination at a median interval of 15 (IQR, 11.3-27.7) months and were included in the serial analysis. A total of 81.9% of patients (7208 of 8810) had stable Agile 3+ scores and 92.6% of patients (8163 of 8810) had stable Agile 4 scores (same risk categories at both assessments). The incidence of LREs was 0.6 per 1000 person-years in patients with persistently low Agile 3+ scores and 30.1 per 1000 person-years in patients with persistently high Agile 3+ scores. In patients with high Agile 3+ score at baseline, a decrease in the score by more than 20% was associated with substantial reduction in the risk of LREs. A similar trend was observed for the Agile 4 score, although it missed more LREs in the low-risk group. Conclusions and Relevance Findings of this study suggest that single or serial Agile scores are highly accurate in predicting LREs in patients with MASLD, making them suitable alternatives to liver biopsy in routine clinical practice and in phase 2b and 3 clinical trials for steatohepatitis.
Collapse
|
48
|
Castillo B, Marulanda J, Thomson P. Experimental Evaluation of Pedestrian-Induced Multiaxial Gait Loads on Footbridges: Effects of the Structure-to-Human Interaction by Lateral Vibrating Platforms. SENSORS (BASEL, SWITZERLAND) 2024; 24:2517. [PMID: 38676134 PMCID: PMC11054870 DOI: 10.3390/s24082517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/27/2024] [Accepted: 03/01/2024] [Indexed: 04/28/2024]
Abstract
The introduction of resistant and lightweight materials in the construction industry has led to civil structures being vulnerable to excessive vibrations, particularly in footbridges exposed to human-induced gait loads. This interaction, known as Human-Structure Interaction (HSI), involves a complex interplay between structural vibrations and gait loads. Despite extensive research on HSI, the simultaneous effects of lateral structural vibrations with fundamental frequencies close to human gait frequency (around 1.0 Hz) and wide amplitudes (over 30.0 mm) remain inadequately understood, posing a contemporary structural challenge highlighted by incidents in iconic bridges like the Millennium Bridge in London, Solferino Bridge in Paris, and Premier Bridge in Cali, Colombia. This paper focuses on the experimental exploration of Structure-to-Human Interaction (S2HI) effects using the Human-Structure Interaction Multi-Axial Test Framework (HSI-MTF). The framework enables the simultaneous measurement of vertical and lateral loads induced by human gait on surfaces with diverse frequency ranges and wide-amplitude lateral harmonic motions. The study involved seven test subjects, evaluating gait loads on rigid and harmonic lateral surfaces with displacements ranging from 5.0 to 50.0 mm and frequency content from 0.70 to 1.30 Hz. A low-cost vision-based motion capture system with smartphones analyzed the support (Tsu) and swing (Tsw) periods of human gait. Results indicated substantial differences in Tsu and Tsw on lateral harmonic protocols, reaching up to 96.53% and 58.15%, respectively, compared to rigid surfaces. Normalized lateral loads (LL) relative to the subject's weight (W0) exhibited a linear growth proportional to lateral excitation frequency, with increased proportionality constants linked to higher vibration amplitudes. Linear regressions yielded an average R2 of 0.815. Regarding normalized vertical load (LV) with respect to W0, a consistent behavior was observed for amplitudes up to 30.0 mm, beyond which a linear increase, directly proportional to frequency, resulted in a 28.3% increment compared to rigid surfaces. Correlation analyses using Pearson linear coefficients determined relationships between structural surface vibration and pedestrian lateral motion, providing valuable insights into Structure-to-Human Interaction dynamics.
Collapse
|
49
|
Dong Y, Noh HY. Ubiquitous Gait Analysis through Footstep-Induced Floor Vibrations. SENSORS (BASEL, SWITZERLAND) 2024; 24:2496. [PMID: 38676114 PMCID: PMC11053483 DOI: 10.3390/s24082496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 04/05/2024] [Accepted: 04/11/2024] [Indexed: 04/28/2024]
Abstract
Quantitative analysis of human gait is critical for the early discovery, progressive tracking, and rehabilitation of neurological and musculoskeletal disorders, such as Parkinson's disease, stroke, and cerebral palsy. Gait analysis typically involves estimating gait characteristics, such as spatiotemporal gait parameters and gait health indicators (e.g., step time, length, symmetry, and balance). Traditional methods of gait analysis involve the use of cameras, wearables, and force plates but are limited in operational requirements when applied in daily life, such as direct line-of-sight, carrying devices, and dense deployment. This paper introduces a novel approach for gait analysis by passively sensing floor vibrations generated by human footsteps using vibration sensors mounted on the floor surface. Our approach is low-cost, non-intrusive, and perceived as privacy-friendly, making it suitable for continuous gait health monitoring in daily life. Our algorithm estimates various gait parameters that are used as standard metrics in medical practices, including temporal parameters (step time, stride time, stance time, swing time, double-support time, and single-support time), spatial parameters (step length, width, angle, and stride length), and extracts gait health indicators (cadence/walking speed, left-right symmetry, gait balance, and initial contact types). The main challenge we addressed in this paper is the effect of different floor types on the resultant vibrations. We develop floor-adaptive algorithms to extract features that are generalizable to various practical settings, including homes, hospitals, and eldercare facilities. We evaluate our approach through real-world walking experiments with 20 adults with 12,231 labeled gait cycles across concrete and wooden floors. Our results show 90.5% (RMSE 0.08s), 71.3% (RMSE 0.38m), and 92.3% (RMSPE 7.7%) accuracy in estimating temporal, spatial parameters, and gait health indicators, respectively.
Collapse
|
50
|
Pfenninger C, Zeghoudi N, Bertrand MF, Lapole T. Effects of prolonged vibration to the flexor carpi radialis muscle on intracortical excitability. Sci Rep 2024; 14:8475. [PMID: 38605084 PMCID: PMC11009410 DOI: 10.1038/s41598-024-59255-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 04/08/2024] [Indexed: 04/13/2024] Open
Abstract
Prolonged local vibration (LV) can induce neurophysiological adaptations thought to be related to long-term potentiation or depression. Yet, how changes in intracortical excitability may be involved remains to be further investigated as previous studies reported equivocal results. We therefore investigated the effects of 30 min of LV applied to the right flexor carpi radialis muscle (FCR) on both short-interval intracortical inhibition (SICI) and intracortical facilitation (ICF). SICI and ICF were measured through transcranial magnetic stimulation before and immediately after 30 min of FCR LV (vibration condition) or 30 min of rest (control condition). Measurements were performed during a low-intensity contraction (n = 17) or at rest (n = 7). No significant SICI nor ICF modulations were observed, whether measured during isometric contractions or at rest (p = 0.2). Yet, we observed an increase in inter-individual variability for post measurements after LV. In conclusion, while intracortical excitability was not significantly modulated after LV, increased inter-variability observed after LV may suggest the possibility of divergent responses to prolonged LV exposure.
Collapse
|