Kataoka S, Yagishita D, Yazaki K, Kanai M, Hasegawa S, Shoda M, Yamaguchi J. Prolonged T-peak to T-end Interval Predicts Implantable Cardioverter Defibrillator Therapy in Patients With Cardiac Sarcoidosis. Circ J 2023:CJ-23-0058. [PMID: 37344406 DOI: 10.1253/circj.cj-23-0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/23/2023]
Abstract
BACKGROUND The association between the T-peak to T-end interval (Tp-e) and ventricular arrhythmia (VA) events in cardiac sarcoidosis (CS) is unknown. The purpose of this study was to investigate whether Tp-e was associated with VA events in CS patients with implantable cardioverter defibrillators (ICDs) or cardiac resynchronization therapy defibrillators (CRT-Ds).Methods and Results: We retrospectively studied 50 patients (16 men; mean [±SD] age 56.3±10.5 years) with CS and ICD/CRT-D. The maximum Tp-e in the precordial leads recorded by a 12-lead electrocardiogram after ICD/CRT-D implantation was evaluated. The clinical endpoint was defined as appropriate ICD therapy. During a median follow-up period of 85.0 months, 22 patients underwent appropriate therapy and 10 patients died. Kaplan-Meier analysis revealed that the probability of the clinical endpoint was 28.3% at 2 years and 35.3% at 4 years. The optimal cut-off value of the Tp-e for the prediction of the clinical endpoint was 91 ms, with a sensitivity of 72.7% and a specificity of 87.0% (area under the curve=0.81). Multivariate Cox regression analysis showed that Tp-e ≥91 ms (hazard ratio [HR] 5.10; 95% confidence interval [CI] 1.99-13.1; P<0.001) and a histological diagnosis of CS (HR 3.84; 95% CI 1.28-11.5; P=0.016) were significantly associated with the clinical endpoint. CONCLUSIONS Tp-e ≥91 ms was a significant predictor of VA events in patients with CS and ICD/CRT-D.
Collapse
|
52
|
Krug D, Zaman A, Eidinger L, Grehn M, Boda-Heggemann J, Rudic B, Mehrhof F, Boldt LH, Hohmann S, Merten R, Buergy D, Fleckenstein J, Kluge A, Rogge A, Both M, Rades D, Tilz RR, Olbrich D, König IR, Siebert FA, Schweikard A, Vonthein R, Bonnemeier H, Dunst J, Blanck O. Radiosurgery for ventricular tachycardia (RAVENTA): interim analysis of a multicenter multiplatform feasibility trial. Strahlenther Onkol 2023:10.1007/s00066-023-02091-9. [PMID: 37285038 DOI: 10.1007/s00066-023-02091-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 04/23/2023] [Indexed: 06/08/2023]
Abstract
BACKGROUND Single-session cardiac stereotactic radiation therapy (SBRT) has demonstrated promising results for patients with refractory ventricular tachycardia (VT). However, the full safety profile of this novel treatment remains unknown and very limited data from prospective clinical multicenter trials are available. METHODS The prospective multicenter multiplatform RAVENTA (radiosurgery for ventricular tachycardia) study assesses high-precision image-guided cardiac SBRT with 25 Gy delivered to the VT substrate determined by high-definition endocardial and/or epicardial electrophysiological mapping in patients with refractory VT ineligible for catheter ablation and an implanted cardioverter defibrillator (ICD). Primary endpoint is the feasibility of full-dose application and procedural safety (defined as an incidence of serious [grade ≥ 3] treatment-related complications ≤ 5% within 30 days after therapy). Secondary endpoints comprise VT burden, ICD interventions, treatment-related toxicity, and quality of life. We present the results of a protocol-defined interim analysis. RESULTS Between 10/2019 and 12/2021, a total of five patients were included at three university medical centers. In all cases, the treatment was carried out without complications. There were no serious potentially treatment-related adverse events and no deterioration of left ventricular ejection fraction upon echocardiography. Three patients had a decrease in VT episodes during follow-up. One patient underwent subsequent catheter ablation for a new VT with different morphology. One patient with local VT recurrence died 6 weeks after treatment in cardiogenic shock. CONCLUSION The interim analysis of the RAVENTA trial demonstrates early initial feasibility of this new treatment without serious complications within 30 days after treatment in five patients. Recruitment will continue as planned and the study has been expanded to further university medical centers. TRIAL REGISTRATION NUMBER NCT03867747 (clinicaltrials.gov). Registered March 8, 2019. Study start: October 1, 2019.
Collapse
|
53
|
Qian S, Monaci S, Mendonca-Costa C, Campos F, Gemmell P, Zaidi HA, Rajani R, Whitaker J, Rinaldi CA, Bishop MJ. Additional coils mitigate elevated defibrillation threshold in right-sided implantable cardioverter defibrillator generator placement: a simulation study. Europace 2023; 25:euad146. [PMID: 37314196 PMCID: PMC10265967 DOI: 10.1093/europace/euad146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 05/13/2023] [Indexed: 06/15/2023] Open
Abstract
AIMS The standard implantable cardioverter defibrillator (ICD) generator (can) is placed in the left pectoral area; however, in certain circumstances, right-sided cans may be required which may increase defibrillation threshold (DFT) due to suboptimal shock vectors. We aim to quantitatively assess whether the potential increase in DFT of right-sided can configurations may be mitigated by alternate positioning of the right ventricular (RV) shocking coil or adding coils in the superior vena cava (SVC) and coronary sinus (CS). METHODS AND RESULTS A cohort of CT-derived torso models was used to assess DFT of ICD configurations with right-sided cans and alternate positioning of RV shock coils. Efficacy changes with additional coils in the SVC and CS were evaluated. A right-sided can with an apical RV shock coil significantly increased DFT compared to a left-sided can [19.5 (16.4, 27.1) J vs. 13.3 (11.7, 19.9) J, P < 0.001]. Septal positioning of the RV coil led to a further DFT increase when using a right-sided can [26.7 (18.1, 36.1) J vs. 19.5 (16.4, 27.1) J, P < 0.001], but not a left-sided can [12.1 (8.1, 17.6) J vs. 13.3 (11.7, 19.9) J, P = 0.099). Defibrillation threshold of a right-sided can with apical or septal coil was reduced the most by adding both SVC and CS coils [19.5 (16.4, 27.1) J vs. 6.6 (3.9, 9.9) J, P < 0.001, and 26.7 (18.1, 36.1) J vs. 12.1 (5.7, 13.5) J, P < 0.001]. CONCLUSION Right-sided, compared to left-sided, can positioning results in a 50% increase in DFT. For right-sided cans, apical shock coil positioning produces a lower DFT than septal positions. Elevated right-sided can DFTs may be mitigated by utilizing additional coils in SVC and CS.
Collapse
|
54
|
Frausing MHJP, Johansen JB, Afonso D, Jørgensen OD, Olsen T, Gerdes C, Johansen ML, Wolff C, Mealing S, Nielsen JC, Kronborg MB. Cost-effectiveness of an antibacterial envelope for infection prevention in patients undergoing cardiac resynchronization therapy reoperations in Denmark. Europace 2023; 25:euad159. [PMID: 37345858 PMCID: PMC10286568 DOI: 10.1093/europace/euad159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Accepted: 06/03/2023] [Indexed: 06/23/2023] Open
Abstract
AIMS Use of an absorbable antibacterial envelope during implantation prevents cardiac implantable electronic device infections in patients with a moderate-to-high infection risk. Previous studies demonstrated that an envelope is cost-effective in high-risk patients within German, Italian, and English healthcare systems, but these analyses were based on limited data and may not be generalizable to other healthcare settings. METHODS AND RESULTS A previously published decision-tree-based cost-effectiveness model was used to compare the costs per quality-adjusted life year (QALY) associated with adjunctive use of an antibacterial envelope for infection prevention compared to standard-of-care intravenous antibiotics. The model was adapted using data from a Danish observational two-centre cohort study that investigated infection-risk patients undergoing cardiac resynchronization therapy (CRT) reoperations with and without an antibacterial envelope (n = 1943). We assumed a cost-effectiveness threshold of €34 125/QALY gained, based on the upper threshold used by the National Institute for Health and Care Excellence (£30 000). An antibacterial envelope was associated with an incremental cost-effectiveness ratio (ICER) of €12 022 per QALY in patients undergoing CRT reoperations, thus indicating that the envelope is cost-effective when compared with standard of care. A separate analysis stratified by device type showed ICERS of €6227 (CRT defibrillator) and €29 177 (CRT pacemaker) per QALY gained. CONCLUSIONS Cost-effectiveness ratios were favourable for patients undergoing CRT reoperations in the Danish healthcare system, and thus are in line with previous studies. Results from this study can contribute to making the technology available to Danish patients and align preventive efforts in the pacemaker and ICD area.
Collapse
|
55
|
Costa T, Bagnall A, Murray S, Bailey K, MacGowan G, Ng WF, McKinnon I, Watson S, McAllister-Williams RH. Role of autonomic dysregulation in quality of life and functional impairment in implantable cardioverter defibrillator patients. J Psychosom Res 2023; 171:111390. [PMID: 37270908 DOI: 10.1016/j.jpsychores.2023.111390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 05/26/2023] [Accepted: 05/27/2023] [Indexed: 06/06/2023]
|
56
|
Lennerz C, Schaarschmidt C, Blažek P, Knoll K, Kottmaier M, Reents T, Bourier F, Lengauer S, Popa M, Wimbauer K, Bahlke F, Krafft H, Englert F, Friedrich L, Schunkert H, Hessling G, Deisenhofer I, Kolb C, O'Connor M. High-power chargers for electric vehicles: are they safe for patients with pacemakers and defibrillators? Europace 2023; 25:euad042. [PMID: 37067822 PMCID: PMC10227864 DOI: 10.1093/europace/euad042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 01/25/2023] [Indexed: 04/18/2023] Open
Abstract
AIMS Battery electric vehicle (BEV) sales and use are rapidly expanding. Battery electric vehicles, along with their charging stations, are a potential source of electromagnetic interference (EMI) for patients with cardiac implantable electronic devices (CIEDs). The new 'high-power' charging stations have the potential to create strong electromagnetic fields and induce EMI in CIEDs, and their safety has not been evaluated. METHODS AND RESULTS A total of 130 CIED patients performed 561 charges of four BEVs and a test vehicle (350 kW charge capacity) using high-power charging stations under continuous 6-lead electrocardiogram monitoring. The charging cable was placed directly over the CIED, and devices were programmed to maximize the chance of EMI detection. Cardiac implantable electronic devices were re-interrogated after patients charged all BEVs and the test vehicle for evidence of EMI. There were no incidences of EMI, specifically no over-sensing, pacing inhibition, inappropriate tachycardia detection, mode switching, or spontaneous reprogramming. The risk of EMI on a patient-based analysis is 0/130 [95% confidence interval (CI) 0%-2%], and the risk of EMI on a charge-based analysis is 0/561 (95% CI 0%-0.6%). The effective magnetic field along the charging cable was 38.65 µT and at the charging station was 77.9 µT. CONCLUSIONS The use of electric cars with high-power chargers by patients with cardiac devices appears to be safe with no evidence of clinically relevant EMI. Reasonable caution, by minimizing the time spent in close proximity with the charging cables, is still advised as the occurrence of very rare events cannot be excluded from our results.
Collapse
|
57
|
Maeda T, Yoshizawa K, Watanabe K, Mori O, Toyota N. Defibrillator electrode placement in the pleural cavity for a child. Asian Cardiovasc Thorac Ann 2023:2184923231171998. [PMID: 37093739 DOI: 10.1177/02184923231171998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
Implantable cardioverter defibrillators are implanted in children to prevent sudden death due to life-threatening ventricular arrhythmias. Transvenous electrode placement is difficult for children because of the small vessel size. Especially, defibrillator electrode placement requires other innovative techniques. We successfully implanted a defibrillator electrode in the pleural cavity using a thoracoscopic approach for a 4-year-old child with sodium channelopathy.
Collapse
|
58
|
Migliore F, Pittorru R, De Lazzari M, Cipriani A, Bauce B, Marra MP, Giacomin E, Dall'Aglio P, Accinelli S, Iliceto S, Corrado D. Third-generation subcutaneous implantable cardioverter defibrillator and intermuscular two-incision implantation technique in patients with Arrhythmogenic cardiomyopathy: 3-year follow-up. Int J Cardiol 2023; 382:33-39. [PMID: 37059308 DOI: 10.1016/j.ijcard.2023.04.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/07/2023] [Accepted: 04/11/2023] [Indexed: 04/16/2023]
Abstract
BACKGROUND Long-term data on the potential advantages of combining the third-generation subcutaneous implantable cardioverter defibrillator (S-ICD) with modern software upgrade including the "SMART Pass", modern programming strategies and the intermuscular (IM) two-incision implantation technique in arrhythmogenic cardiomyopathy (ACM) with different phenotypic variants are lacking. In this study we evaluated the long-term outcome of patients with ACM who underwent third-generation S-ICD (Emblem, Boston Scientific) and IM two-incision technique. METHODS The study population included 23 consecutive patients [70% male, median age 31 (24-46) years] diagnosed with ACM with different phenotypic variants who received third-generation S-ICD implantation with the IM two-incision technique. RESULTS During a median follow-up of 45.5 months [16-65], 4 patients (17.4%) received a at least one inappropriate shock (IS), with median annual event rate of 4.5%. Extra-cardiac oversensing (myopotential) during effort represented the only cause of IS. No IS due to T-wave oversensing (TWOS) were recorded. Only one patient (4.3%) experienced device-related complication consisting of premature cell battery depletion requiring device replacement. No device explantation because of need for anti-tachycardia pacing or ineffective therapy occurred. There was no significant difference between patients who did and did not experienced IS with regard to baseline clinical, ECG and technical characteristics. Five patients (21.7%) received appropriate shock on ventricular arrythmias. CONCLUSIONS According to our finding, although the third-generation S-ICD implanted with the IM two-incision technique appears to be associated with a low risk of complications and IS due to cardiac oversensing, the risk of IS due to myopotential mainly during effort should be considered.
Collapse
|
59
|
van der Lingen ALCJ, Rijnierse MT, Hooghiemstra AM, Elshout S, van Halm VP, Batelaan NM, van Rossum AC, Pedersen SS, Leeuwis AE, Allaart CP. The link between cardiac status and depression and anxiety in implantable cardioverter defibrillator patients: Design and first results of the PSYCHE-ICD study. J Psychosom Res 2023; 167:111182. [PMID: 36801661 DOI: 10.1016/j.jpsychores.2023.111182] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 01/07/2023] [Accepted: 02/03/2023] [Indexed: 02/12/2023]
Abstract
OBJECTIVE Depression and anxiety in patients with an implantable cardioverter-defibrillator (ICD) are associated with adverse outcomes. This study describes the design of the PSYCHE-ICD study and evaluates the correlation between cardiac status and depression and anxiety in ICD patients. METHODS We included 178 patients. Prior to implantation, patients completed validated psychological questionnaires for depression, anxiety and personality traits. Cardiac status was evaluated by means of left ventricular ejection fraction assessment (LVEF), New York Heart Association (NYHA) functional class, 6-minute walk test (6MWT), and 24-h Holter monitoring for heart rate variability (HRV). A cross-sectional analysis was performed. Follow-up with annual study visits, including repeated full cardiac evaluation, will continue 36 months after ICD implantation. RESULTS Depressive symptoms were present in 62 (35%) and anxiety in 56 (32%) patients. Values of depression and anxiety significantly increased with higher NYHA class (P < 0.001). Depression symptoms were correlated with a reduced 6MWT (411 ± 128 vs. 488 ± 89, P < 0.001), higher heart rate (74 ± 13 vs. 70 ± 13, P = 0.02), higher thyroid stimulation hormone levels (1.8 [1.3-2.8] vs 1.5 [1.0-2.2], P = 0.03) and multiple HRV parameters. Anxiety symptoms were correlated with higher NYHA class and a reduced 6MWT (433 ± 112 vs 477 ± 102, P = 0.02). CONCLUSION A substantial part of patients receiving an ICD have symptoms of depression and anxiety at time of ICD implantation. Depression and anxiety were correlated with multiple cardiac parameters, suggesting a possible biological links between psychological distress and cardiac disease in ICD patients.
Collapse
|
60
|
Kolk MZH, Narayan SM, Clopton P, Wilde AAM, Knops RE, Tjong FVY. Reduction in long-term mortality using remote device monitoring in a large real-world population of patients with implantable defibrillators. Europace 2023; 25:969-977. [PMID: 36636951 PMCID: PMC10062290 DOI: 10.1093/europace/euac280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Accepted: 11/23/2022] [Indexed: 01/14/2023] Open
Abstract
AIMS Remote monitoring (RM) for implantable cardioverter-defibrillators (ICDs) is advocated for the potential of early detection of disease progression and device dysfunction. While studies have examined the effect of RM on clinical outcomes in carefully selected populations of heart failure patients implanted with ICDs from a single vendor, there is a paucity of data in real-world patients. We aimed to assess the long-term effect of RM in a representative ICD population using real-world data. METHODS AND RESULTS This is an observational retrospective longitudinal study of 1004 patients implanted with an ICD or cardiac resynchronization therapy device (CRT-D) from all device vendors between 2010 and 2021. Patients started on RM (N = 403) within 90 days following de novo device implantation and yearly in-office visits were compared with patients with only bi-yearly in-office follow-up (non-RM, N = 601). In a propensity score matched cohort of 430 patients (mean age 61.4 ± 14.3 years, 26.7% female), all-cause mortality at 4-year was 12.6% in the RM and 27.7% in the non-RM group [hazard ratio (HR) 0.52, 95% confidence interval (CI) 0.32-0.82; P = 0.005]. No difference in inappropriate ICD-therapy (HR 1.90, 95% CI 0.86-4.21; P = 0.122) was observed. The risk of appropriate ICD-therapy (HR 1.71, 95% CI 1.07-2.74; P = 0.026) was higher in the RM group. CONCLUSION Remote monitoring was associated with a reduction in long-term all-cause and cardiac mortality compared with traditional office visits in a real-world ICD population.
Collapse
|
61
|
Samy Awad S, Abouelatta Elmowafy M, Ahmed Khalil AS, El-Damaty A. Inappropriate shocks following recent generator replacement. Herzschrittmacherther Elektrophysiol 2023; 34:68-70. [PMID: 36662258 DOI: 10.1007/s00399-022-00918-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 12/12/2022] [Indexed: 01/21/2023]
Abstract
In a 64-year-old male patient with an implantable cardioverter defibrillator (ICD) for secondary prevention of sudden cardiac death, a shock occurred some months after generator exchange and downgrade to a single-chamber system. Careful analysis of the stored electrogram revealed a rare cause that could be confirmed at the time of operative revision.
Collapse
|
62
|
Archontakis S, Oikonomou E, Sideris K, Laina A, Tirovola D, Paraskevopoulou D, Kostakis P, Doundoulakis I, Arsenos P, Ntalakouras I, Charitakis E, Gatzoulis K, Tsioufis K, Sideris S. Safety of same-day discharge versus overnight stay strategy following cardiac device implantations: a high-volume single-centre experience. J Interv Card Electrophysiol 2023; 66:471-481. [PMID: 36063282 PMCID: PMC9442569 DOI: 10.1007/s10840-022-01319-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 07/21/2022] [Indexed: 11/26/2022]
Abstract
BACKGROUND The strategy of cardiac implantable electronic device (CIED) implantations performed as day-case admissions has gained a wider acceptance overtime; however, data on safety are still limited. This study aims to investigate the safety of a same-day discharge protocol introduced in our hospital for the postprocedural management of patients undergoing CIED implantation. METHODS Α prospective, non-interventional, non-randomised study performed in a single high-volume implanting centre for a 16-month period (March 2020 to June 2021). At total of 821 of 965 (85.1%) patients scheduled for elective CIED implantation were considered to be eligible for inclusion in the Short-stay Device Management Protocol. These patients were compared with a historical group of 932 patients, meeting the same inclusion criteria. RESULTS Procedure was successful in 812 patients (98.9%), committed to same-day discharge versus 921 of 932 patients (98.8%) admitted for overnight stay (p = 0.87). Overall, 90-day complication rate was comparable in both groups (4.14% vs 4.07%, p = 0.95), as was major (1.46% vs. 1.82%, p = 0.55) and minor (2.67% vs. 2.25%, p = 0.64) complication rates. The composite early post-procedural complication rates and late post-procedural complication rates were comparable among groups (0.97 vs 1.18%, p = 0.70 and 0.73% vs 0.64%, p = 0.83, respectively). Six hundred sixty-seven patients (84%) preferred the same-day discharge strategy. Finally, a reduction of 792 bed-days was recorded, resulting in possible financial Health System benefits. CONCLUSIONS Same-day discharge is feasible and safe in the majority of patients referred for CIED implantation. Additionally, same-day discharge is preferred by patients and may reduce procedure-related costs due to significant bed-day reductions.
Collapse
|
63
|
Wood-Kurland HK, Phelps M, Thune JJ, Philbert B, Larroudé CE, Schou M, Hansen ML, Gislason GH, Bang CN. Impact of Nationwide COVID-19 Lockdowns on the Implantation Rate of Cardiac Implantable Electronic Devices. Heart Lung Circ 2023; 32:364-372. [PMID: 36513581 PMCID: PMC9741195 DOI: 10.1016/j.hlc.2022.10.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Revised: 09/05/2022] [Accepted: 10/20/2022] [Indexed: 12/14/2022]
Abstract
AIM The COVID-19 pandemic resulted in a significant decrease in the number of hospital admissions for severe emergent cardiovascular diseases during lockdowns worldwide. This study aimed to determine the impact of both the first and the second Danish nationwide lockdown on the implantation rate of cardiac implantable electronic devices (CIEDs). METHODS We retrospectively analysed the number of CIED implantations performed in Denmark and stratified them into 3-week intervals. RESULTS The total number of de novo CIED implantations decreased during the first lockdown by 15.5% and during the second by 5.1%. Comparing each 3-week interval using rate ratios, a significant decrease in the daily rates of the total number of de novo and replacement CIEDs (0.82, 95% CI [0.70, 0.96]), de novo CIEDs only (0.82, 95% CI [0.69, 0.98]), and non-acute pacemaker implantations (0.80, 95% CI [0.63, 0.99]) was observed during the first interval of the first lockdown. During the second lockdown (third interval), a significant decrease was seen in the daily rates of de novo CIEDs (0.73, 95% CI [0.55, 0.97]), and of pacemakers in total during both the second (0.78, 95% CI [0.62, 0.97]) and the third (0.60, 95% CI [0.42, 0.85]) intervals. Additionally, the daily rates of acute pacemaker implantation decreased during the second interval (0.47, 95% CI [0.27, 0.79]) and of non-acute implantation during the third interval (0.57, 95% CI [0.38, 0.84]). A significant increase was observed in the number of replacement procedures during the first interval of the second lockdown (1.70, 95% CI [1.04, 2.85]). CONCLUSIONS Our study found only modest changes in CIED implantations in Denmark during two national lockdowns.
Collapse
|
64
|
Qian S, Connolly A, Mendonca-Costa C, Campos F, Rodero C, Whitaker J, Rinaldi CA, Bishop MJ. Optimization of anti-tachycardia pacing efficacy through scar-specific delivery and minimization of re-initiation: a virtual study on a cohort of infarcted porcine hearts. Europace 2023; 25:716-725. [PMID: 36197749 PMCID: PMC9935023 DOI: 10.1093/europace/euac165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 08/31/2022] [Indexed: 11/15/2022] Open
Abstract
AIMS Anti-tachycardia pacing (ATP) is a reliable electrotherapy to painlessly terminate ventricular tachycardia (VT). However, ATP is often ineffective, particularly for fast VTs. The efficacy may be enhanced by optimized delivery closer to the re-entrant circuit driving the VT. This study aims to compare ATP efficacy for different delivery locations with respect to the re-entrant circuit, and further optimize ATP by minimizing failure through re-initiation. METHODS AND RESULTS Seventy-three sustained VTs were induced in a cohort of seven infarcted porcine ventricular computational models, largely dominated by a single re-entrant pathway. The efficacy of burst ATP delivered from three locations proximal to the re-entrant circuit (septum) and three distal locations (lateral/posterior left ventricle) was compared. Re-initiation episodes were used to develop an algorithm utilizing correlations between successive sensed electrogram morphologies to automatically truncate ATP pulse delivery. Anti-tachycardia pacing was more efficacious at terminating slow compared with fast VTs (65 vs. 46%, P = 0.000039). A separate analysis of slow VTs showed that the efficacy was significantly higher when delivered from distal compared with proximal locations (distal 72%, proximal 59%), being reversed for fast VTs (distal 41%, proximal 51%). Application of our early termination detection algorithm (ETDA) accurately detected VT termination in 79% of re-initiated cases, improving the overall efficacy for proximal delivery with delivery inside the critical isthmus (CI) itself being overall most effective. CONCLUSION Anti-tachycardia pacing delivery proximal to the re-entrant circuit is more effective at terminating fast VTs, but less so slow VTs, due to frequent re-initiation. Attenuating re-initiation, through ETDA, increases the efficacy of delivery within the CI for all VTs.
Collapse
|
65
|
Le Bos PA, Pontailler M, Maltret A, Kraiche D, Gaudin R, Barbanti C, Marijon E, Raisky O, Bonnet D, Waldmann V. Epicardial vs. transvenous implantable cardioverter defibrillators in children. Europace 2023; 25:961-968. [PMID: 36735263 PMCID: PMC10062323 DOI: 10.1093/europace/euad015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Accepted: 10/23/2022] [Indexed: 02/04/2023] Open
Abstract
AIMS The implantable cardioverter defibrillator (ICD) has been increasingly used in children. Both epicardial and transvenous approaches are used, with controversy regarding the best option with no specific recommendations. We aimed to compare outcomes associated with epicardial vs. transvenous ICDs in children. METHODS AND RESULTS Data were analysed from a retrospective study including all patients <18-year-old implanted with an ICD in a tertiary centre from 2003 to 2021. Outcomes were compared between epicardial and transvenous ICDs. A total of 122 children with an ICD (mean age 11.5 ± 3.8 years, 57.4% males) were enrolled, with 84 (64.1%) epicardial ICDs and 38 (29.0%) transvenous ICDs. Early (<30 days) ICD-related complications were reported in 17 (20.2%) patients with an epicardial ICD vs. 0 (0.0%) with a transvenous ICD (P = 0.002). Over a mean follow-up of 4.8 ± 4.0 years, 25 (29.8%) patients with an epicardial ICD and 9 (23.7%) patients with a transvenous ICD experienced at least one late ICD-related complication [hazard ratio (HR) 1.8, 95% confidence interval (CI) 0.8-4.0]. Implantable cardioverter defibrillator lead dysfunction occurred in 19 (22.6%) patients with an epicardial ICD vs. 3 (7.9%) with a transvenous ICD (HR 5.7, 95% CI 1.3-24.5) and was associated with a higher incidence of ICD-related reintervention (HR 3.0, 95% CI 1.3-7.0). After considering potential confounders, especially age and weight at implantation, this association was no longer significant (P = 0.112). The freedom from ICD lead dysfunction was greater in patients with pleural coils than in those with epicardial coils (HR 0.38, 95% CI 0.15-0.96). CONCLUSION In children, after a consideration of patient characteristics at implantation, the burden of complications and ICD lead dysfunction appears to be similar in patients with epicardial and transvenous devices. Pleural coils seem to be associated with better outcomes than epicardial coils in this population. CLINICAL TRIAL REGISTRATION NCT05349162.
Collapse
|
66
|
Effect of implantable cardioverter defibrillator on primary prevention of sudden cardiac death in high-risk patients. Am J Transl Res 2023; 15:1352-1359. [PMID: 36915722 PMCID: PMC10006803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 12/25/2022] [Indexed: 03/16/2023]
Abstract
OBJECTIVE To investigate the effect of implantable cardioverter defibrillator (ICD) on primary prevention of sudden cardiac death (SCD) in patients with high risk. METHODS This retrospective analysis included 70 patients who received primary prevention of SCD by ICD implantation in Huzhou Central Hospital from March 2016 to May 2019. Based on survival, 15 patients who died during follow-up were placed into the death group and the 55 patients who survived were set as the survival group. The two groups were compared in terms of sex, age, non-sustained ventricular tachycardia (VT), diastolic pressure, systolic pressure, left ventricular ejection fraction (LVEF), urea nitrogen, serum creatinine, history of diabetes, history of atrial fibrillation, history of myocardial ischemia, history of dilated cardiomyopathy, history of hypertrophic cardiomyopathy, type I Brugada wave and cardiac function classification. Further, we analyzed the proportion of discharge, the survival of patients (Kaplan Meier method), and the risk factors of patient death (Logistic regression). RESULTS The analysis of baseline data showed that patients in the death group had older age and higher level of serum creatinine than the survival group (P<0.05), and the number of patients with non-sustained VT≥5 times/24 h in the survival group was higher than that in the death group (P<0.05). There was no obvious difference in other baseline indexes between the two groups (P>0.05). In addition, there was no difference in the proportion of patients receiving appropriate/inappropriate discharge (P>0.05) between the two groups. Follow-up data showed that 15 cases (21.43%) of spontaneous VT/ventricular fibrillation events were correctly diagnosed by pacemakers and properly treated by ICD (discharge or antitachycardia pacing (ATP)), while 55 cases (78.57%) received inappropriate ICD treatment. There were 15 patients (21.43%) who died during follow up, including 6 cases of cardiac insufficiency, 1 case of SCD, 2 cases of acute myocardial infarction, 1 case of respiratory failure, and 5 cases of unknown etiology; the survival time was (20.27±7.06) months. Logistic regression analysis showed that age and serum creatinine were the risk factors of patient death. CONCLUSION Primary prevention with ICD implantation benefits SCD patients. Non persistent VT≥5 times/24 h is a predictive value for ICD implantation in patients receiving primary prevention of SCD. Age and serum creatinine are risk factors for death.
Collapse
|
67
|
Muhammed A, Abdelazeem M, Elewa MG, Sharief M, Ammar A. Primary prevention implantable cardioverter-defibrillator use in non-ischemic dilated cardiomyopathy based on arrhythmic risk stratification and left ventricular reverse remodeling prediction. Heart Fail Rev 2023; 28:229-240. [PMID: 35587303 PMCID: PMC9902308 DOI: 10.1007/s10741-022-10246-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/04/2022] [Indexed: 02/07/2023]
Abstract
Sudden cardiac death (SCD) and significant ventricular arrhythmias in patients with dilated cardiomyopathy (DCM) have been markedly reduced over the last couple of decades as a result of the advances in pharmacological and non-pharmacological treatment. Primary prevention implantable cardioverter-defibrillator (ICD) plays an important role in the treatment of patients at risk of SCD caused by ventricular arrhythmias. However, the arrhythmic risk stratification in patients with DCM remains extremely challenging, and the decision for primary prevention ICD implantation based on left ventricular ejection fraction (LVEF) solely appears to be insufficient. This review provides an update on current evidence for primary prevention ICD implantation, arrhythmic risk stratification, and left ventricular reverse remodeling (LVRR) prediction in patients with DCM in addition to most recent guideline recommendations for primary prevention ICD implantation in DCM patients and a proposed multiparametric algorithm based on arrhythmic risk stratification and left ventricular reverse remodeling (LVRR) prediction to better identify patients who are likely to benefit from primary prevention ICD.
Collapse
|
68
|
Andersen CM, Johansen JB, Wehberg S, Nielsen JC, Riahi S, Haarbo J, Philbert BT, Pedersen SS. Sex differences in the course of implantable cardioverter defibrillator concerns (Results from the Danish national DEFIB-WOMEN study). J Psychosom Res 2023; 164:111072. [PMID: 36459826 DOI: 10.1016/j.jpsychores.2022.111072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 10/17/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The implantable cardioverter defibrillator (ICD) is used to treat malignant ventricular arrhythmias. Since 33% of patients experience ICD-related concerns, we examined sex differences in ICD concerns and correlates of ICD concerns during 24 months of follow-up after implantation of an ICD. METHODS Patients from the DEFIB-WOMEN study (n = 1515; 81.6% male patients) completed questionnaires on ICD concerns, anxiety, depression, and Type D personality at five measure points (baseline, 3-, 6-, 12- and 24-months post-implantation). RESULTS Male patients scored on average 7.0 (6.8) points on ICD concerns at the time of implantation and female patients scored on average 10.5 (8.2) points. We found statistically significant sex differences in ICD concerns at all measurement points, with female patients scoring 2.77 points (8.7% of the maximum score of 32) higher than male patients. ICD concerns decreased in both sexes the first 6 months and then levelled out. For both sexes, ICD concerns at baseline were significantly correlated with ICD concerns at 24-months follow-up. Anxiety at baseline was correlated with ICD concerns in female patients, while depression at baseline and at least one experienced shock correlated with ICD concerns in male patients. CONCLUSION Female patients reported more ICD concerns at all measurement points compared to male patients, but for both sexes ICD concerns decreased in the first 6 months. ICD shock, anxiety, depression, and ICD concerns at baseline were correlates of ICD concerns at 24-months follow-up.
Collapse
|
69
|
Pedersen SS, Wehberg S, Nielsen JC, Riahi S, Larroudé C, Philbert BT, Johansen JB. Patients with an implantable cardioverter defibrillator at risk of poorer psychological health during 24 months of follow-up (results from the Danish national DEFIB-WOMEN study). Gen Hosp Psychiatry 2023; 80:54-61. [PMID: 36638700 DOI: 10.1016/j.genhosppsych.2022.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 12/21/2022] [Accepted: 12/26/2022] [Indexed: 01/05/2023]
Abstract
OBJECTIVE Identify implantable cardioverter defibrillator (ICD) patients at risk of distress (i.e., depression, anxiety, and ICD concerns) and associated risk factors. METHOD First-time ICD patients (n = 1503) from the Danish national DEFIB-WOMEN study completed questionnaires at baseline, 3, 6, 12 and 24 months. RESULTS Of patients with low scores on distress, only 4%-7.2% experienced an increase in distress during 24 months of follow-up (FU), while 30.5%-52.5% with increased levels were likely to maintain increased levels at FU. Higher education, higher age, female sex, and good physical functioning at baseline were associated with less depression, anxiety and ICD concerns at FU. Previous psychological problems, smoking, Type D personality, NYHA class III-IV - all assessed at baseline - and shocks during FU were associated with depression, anxiety and ICD concerns. CONCLUSIONS Generally, patients' psychological health improved, but patients with increased baseline scores were more likely to have increased scores at FU. We need to be vigilant if patients report elevated distress, particularly if they have depression at baseline, as depression seems more persistent. Given the impact of depression on health-related quality of life and prognosis, they should be screened and monitored closely.
Collapse
|
70
|
Garcia R, Marijon E, Karam N, Narayanan K, Anselme F, Césari O, Champ-Rigot L, Manenti V, Martins R, Puymirat E, Ferrières J, Schiele F, Simon T, Danchin N. Ventricular fibrillation in acute myocardial infarction: 20-year trends in the FAST-MI study. Eur Heart J 2022; 43:4887-4896. [PMID: 36303402 DOI: 10.1093/eurheartj/ehac579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 08/05/2022] [Accepted: 09/29/2022] [Indexed: 01/12/2023] Open
Abstract
AIMS Sudden cardiac arrest remains a major complication of acute myocardial infarction (AMI) and is frequently related to ventricular fibrillation (VF). Incidence and impact of VF among patients hospitalized for AMI were evaluated. METHODS AND RESULTS Data from the FAST-MI programme consisting of 5 French nationwide prospective cohort studies between 1995 and 2015 were analysed, totally including 14 423 patients with AMI (66 ± 14 years, 72% males, 59% ST-elevation myocardial infarction). Overall, proportion of patients presenting in-hospital VF decreased from 3.9% in 1995 to 1.8% in 2015 (P < 0.001). One-year mortality decreased from 60.7% to 24.6% (P < 0.001). However, compared with patients who did not develop VF, the over-risk of 1-year mortality associated with VF was stable over time [hazard ratio (HR) 6.78, 95% confidence interval (CI) 5.03-9.14 in 1995 and HR 6.64, 95% CI 4.20-10.49 in 2015, P = 0.52]. This increased mortality in the VF group was mainly related to fatal events occurring prior to hospital discharge, representing 86.2% of 1-year mortality, despite the very low rate of implantable cardioverter defibrillator in the VF group (2.6%). CONCLUSION This study demonstrates that in-hospital VF incidence and mortality in the setting of AMI have significantly decreased over the past 20 years. Nevertheless, VF remained steadily associated with approximately a 10-fold increased relative risk of in-hospital mortality, without an impact on post-discharge mortality. Beyond long-term cardiac defibrillation strategy, these results emphasize the need to identify in-hospital interventions to further reduce mortality in VF patients. STUDY REGISTRATION ClinicalTrials.gov Identifier: NCT00673036, NCT01237418, NCT02566200.
Collapse
|
71
|
Forman J, Murtagh E, Cheung J, Chakrabarti S, Macleod S, MacEwing C, Owens S, Alley H, Bangma K, Villeneuve M, Lauck S. Development of a patient and clinician co-led education program to promote living well with an implantable cardioverter defibrillator: Insights from a pilot project. PEC INNOVATION 2022; 1:100104. [PMID: 37213750 PMCID: PMC10194333 DOI: 10.1016/j.pecinn.2022.100104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 11/07/2022] [Accepted: 11/14/2022] [Indexed: 05/23/2023]
Abstract
Objective To evaluate a pilot education program designed to improve patients' experience of living well with an implantable cardioverter-defibrillator (ICD). Methods Patient Partners with previously implanted ICD and clinicians collaboratively performed monthly education sessions for potential and recent ICD recipients. Curriculum development was informed by current evidence of ICD patients' unique educational needs; delivery format transitioned to a virtual platform following the onset of COVID-19. Participants' experience was evaluated using a tailored questionnaire to explore preliminary insights. Results 126 participants (median age: 62 years; women: 30%) attended 24 sessions. In-person participants (n = 62, 49.2%) reported sessions as helpful (n = 56, 94%) with regards to format and Patient Partner interactions. Virtual participants 64 (50.8%) completed an electronic survey (n = 27, 45%); reporting sufficient information for most topics with the exception of potential psychological effects of ICD implantation. Patient Partners as collaborative session leaders was perceived to be very helpful (n = 22, 82%) or somewhat helpful (n = 5, 18%). Conclusion This novel educational partnership met the learning needs of patients at the vulnerable time of new cardiac device implantation of both in-person and virtual formats. Innovation The inclusion of Patient Partners in co-led cardiac education informs novel approach to care that may improve patients' experiences of living well with complex technology.
Collapse
|
72
|
Fluschnik N, Tahir E, Erley J, Müllerleile K, Metzner A, Wenzel JP, Guerreiro H, Adam G, Blankenberg S, Kirchhof P, Tönnis T, Nikorowitsch J. 3 Tesla magnetic resonance imaging in patients with cardiac implantable electronic devices: a single centre experience. Europace 2022; 25:571-577. [PMID: 36413601 PMCID: PMC9935018 DOI: 10.1093/europace/euac213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 11/01/2022] [Indexed: 11/23/2022] Open
Abstract
AIMS Three Tesla (T) magnetic resonance imaging (MRI) provides critical imaging information for many conditions. Owing to potential interactions of the magnetic field, it is largely withheld from patients with cardiac implantable electronic devices (CIEDs). Therefore, we assessed the safety of 3T MRI in patients with '3T MRI-conditional' and 'non-3T MRI-conditional' CIEDs. METHODS AND RESULTS We performed a retrospective single-centre analysis of clinically indicated 3T MRI examinations in patients with conventional pacemakers, cardiac resynchronization devices, and implanted defibrillators from April 2020 to May 2022. All CIEDs were interrogated and programmed before and after scanning. Adverse events included all-cause death, arrhythmias, loss of capture, inappropriate anti-tachycardia therapies, electrical reset, and lead or generator failure during or shortly after MRI. Changes in signal amplitude and lead impedance were systematically assessed. Statistics included median and interquartile range. A total of 132 MRI examinations were performed on a 3T scanner in 97 patients. Thirty-five examinations were performed in patients with 'non-3T MRI-conditional' CIEDs. Twenty-six scans were performed in pacemaker-dependent patients. No adverse events occurred during or shortly after MRI. P-wave or R-wave reductions ≥ 50 and ≥ 25%, respectively, were noted after three (2.3%) scans, all in patients with '3T MRI-conditional' CIEDs. Pacing and shock impedance changed by ± 30% in one case (0.7%). Battery voltage and stimulation thresholds did not relevantly change after MRI. CONCLUSION Pending verification in independent series, our data suggest that clinically indicated MRI scans at 3T field strength should not be withheld from patients with cardiac pacemakers or defibrillators.
Collapse
|
73
|
Zeppenfeld K, Tfelt-Hansen J, de Riva M, Winkel BG, Behr ER, Blom NA, Charron P, Corrado D, Dagres N, de Chillou C, Eckardt L, Friede T, Haugaa KH, Hocini M, Lambiase PD, Marijon E, Merino JL, Peichl P, Priori SG, Reichlin T, Schulz-Menger J, Sticherling C, Tzeis S, Verstrael A, Volterrani M. 2022 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Eur Heart J 2022; 43:3997-4126. [PMID: 36017572 DOI: 10.1093/eurheartj/ehac262] [Citation(s) in RCA: 674] [Impact Index Per Article: 337.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
|
74
|
de la Torre Hernández JM, Lozano González M, García Camarero T, Serrano Lozano D, Cid B, Ojeda S, Jiménez Quevedo P, Serrador A, García Del Blanco B, Díaz JF, Moreno R, Cruz-González I, Pérez de Prado A, Fernández Lozano I, Cano Pérez Ó, Cantarero Prieto D. Interregional variability in the use of cardiovascular technologies (2011-2019). Correlation with economic indicators, admissions, and in-hospital mortality. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2022; 75:805-815. [PMID: 35688688 DOI: 10.1016/j.rec.2022.02.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 02/11/2022] [Indexed: 06/15/2023]
Abstract
INTRODUCTION AND OBJECTIVES Equal opportunities to access technical advances with recognized clinical value should be a priority of the publicly-funded health system. We analyzed variability among all the Spanish autonomous communities in the use of cardiovascular techniques with an established indication and its relationship with economic indicators, burden of disease, and hospital mortality. METHODS The activity registries of various Associations of the Spanish Society of Cardiology from 2011 to 2019 were analyzed for coronary angiography, overall percutaneous coronary intervention (PCI), primary PCI, implantable cardioverter-defibrillators (ICD), cardiac resynchronization therapy, and transcatheter aortic valve replacement (TAVR). Economic indices (gross domestic product and per capita health care expenditure) were obtained from public sources and data on attendance rates and mortality from the Resources and Quality in Cardiology (RECALCAR) reports of the Spanish Society of Cardiology. We analyzed the coefficient of variation for activity and the correlation of activity with regional economic indices, attendance rates, and risk-adjusted rates of in-hospital mortality. RESULTS We identified wide variability in the use of technologies, especially for primary PCI (18%), ICD (22%), cardiac resynchronization therapy (36%), and TAVR (42%). A certain correlation with attendance rates was seen only for overall PCI and ICD. In general, no significant correlation was found between the use of the techniques and the economic indices of wealth and expenditure. The correlation with in-hospital mortality showed no significant results, although this was the analysis with the greatest limitations because the impact of these techniques on survival is exerted more in the mid- and long-term. CONCLUSIONS The results of this study, despite its inherent limitations, show marked variability between autonomous communities in the use of cardiovascular technologies, which is not explained by economic differences or by hospital attendance rates due to the corresponding diseases.
Collapse
|
75
|
Silvetti MS, Bruyndonckx L, Maltret A, Gebauer R, Kwiatkowska J, Környei L, Albanese S, Raimondo C, Paech C, Kempa M, Fésüs G, Knops RE, Blom NA, Drago F. The SIDECAR project: S-IcD registry in European paediatriC and young Adult patients with congenital heaRt defects. Europace 2022; 25:460-468. [PMID: 36107451 PMCID: PMC9935000 DOI: 10.1093/europace/euac162] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 08/04/2022] [Indexed: 11/13/2022] Open
Abstract
AIMS Subcutaneous-implantable cardiac defibrillators (S-ICDs) are used increasingly to prevent sudden cardiac death in young patients. This study was set up to gain insight in the indications for S-ICD, possible complications, and their predictors and follow-up results. METHODS AND RESULTS A multicentre, observational, retrospective, non-randomized, standard-of-care registry on S-ICD outcome in young patients with congenital heart diseases (CHDs), inherited arrhythmias (IAs), idiopathic ventricular fibrillation (IVF), and cardiomyopathies (CMPs). Anthropometry was registered as well as implantation technique, mid-term device-related complications, and incidence of appropriate/inappropriate shocks (IASs). Data are reported as median (interquartile range) or mean ± standard deviation. Eighty-one patients (47% CMPs, 20% CHD, 21% IVF, and 12% IA), aged 15 (14-17) years, with body mass index (BMI) 21.8 ± 3.8 kg/m2, underwent S-ICD implantation (primary prevention in 59%). This was performed with two-incision technique in 81% and with a subcutaneous pocket in 59%. Shock and conditional zones were programmed at 250 (200-250) and 210 (180-240) b.p.m., respectively. No intraoperative complications occurred. Follow up was 19 (6-35) months: no defibrillation failure occurred, 17% of patients received appropriate shocks, 13% of patients received IAS (supraventricular tachycardias 40%, T-wave oversensing 40%, and non-cardiac oversensing 20%). Reprogramming, proper drug therapy, and surgical revision avoided further IAS. Complications requiring surgical revision occurred in 9% of patients, with higher risks in patients with three-incision procedures [hazard ratio (HR) 4.3, 95% confidence interval (95% CI) 0.5-34, P = 0.038] and BMI < 20 (HR 5.1, 95% CI 1-24, P = 0.031). CONCLUSION This multicentre European paediatric registry showed good S-ICD efficacy and safety in young patients. Newer implantation techniques and BMI > 20 showed better outcome.
Collapse
|