76
|
Wincewicz A, Sulkowska M, Lieberman EJ, Bakunowicz-Lazarczyk A, Sulkowski S. Dr Adam Zamenhof (1888-1940) and his insight into ophthalmology. JOURNAL OF MEDICAL BIOGRAPHY 2009; 17:18-22. [PMID: 19190194 DOI: 10.1258/jmb.2008.008037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Adam Zamenhof was greatly influenced by his father, Ludwik Zamenhof, who designed the international language Esperanto. Like his father, he became an ophthalmologist and joined the Esperanto movement. He published in the field of ophthalmology and was soon chosen as head of an ophthalmology department. He subsequently became Chief of the Orthodox Jewish Hospital at Czystem in Warsaw. He was active in the leadership of the Bialystok-Warsaw Chamber of Medical Doctors. He perished in the Nazi Holocaust (Shoah) but all Zamenhof's ideals that Adam served as a doctor and social activist remain still alive.
Collapse
|
77
|
Bahar I, Kaiserman I, Sansanayudh W, Levinger E, Rootman DS. Busin Guide vs Forceps for the Insertion of the Donor Lenticule in Descemet Stripping Automated Endothelial Keratoplasty. Am J Ophthalmol 2009; 147:220-226.e1. [PMID: 18930446 DOI: 10.1016/j.ajo.2008.08.029] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2008] [Revised: 08/19/2008] [Accepted: 08/20/2008] [Indexed: 12/01/2022]
Abstract
PURPOSE To compare two insertion methods in Descemet stripping automated endothelial keratoplasty (DSAEK): Busin guide-assisted vs Forceps-assisted insertion of the corneal lenticule graft. DESIGN Prospective, consecutive, comparative, nonrandomized study. METHODS setting: Cornea clinic at the Toronto Western Hospital. study population: Sixty-three eyes of 63 consecutive patients were included. All patients underwent DSAEK for Fuchs endothelial dystrophy, pseudophakic bullous keratopathy, aphakic bullous keratopathy, failed graft, or iridocorneo endothelial syndrome. Twenty-six consecutive donor discs were inserted with the Busin guide and 37 consecutive eyes underwent forceps assisted insertion of the donor. main outcome measures: Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, corneal endothelial cell loss, and postoperative complications. RESULTS Busin guide-assisted DSAEK group had significantly worse UCVA and lower donor endothelial cell counts preoperatively. No significant differences were noted in the intraoperative or postoperative complications. Six months following surgery, BCVA was not significantly different between groups: 20/37 in the Busin guide-assisted DASEK group vs 20/42 in the Forceps-assisted group (P = .39). Mean spherical equivalent was -0.02 diopters (D) and 0.82 D (P = .06), and mean refractive cylinder was 2.2 D and 1.31 D (P = .0006), respectively. Endothelial cell loss was significantly lower in the Busin guide-assisted DASEK group: 25% loss vs 34.3% loss in the Forceps-assisted DSAEK group. (P = .04). CONCLUSIONS Although visual outcomes were not different between the groups studied, Busin guide-assisted DSAEK resulted in lower percentage of endothelial cell loss compared with forceps insertion, six months following surgery.
Collapse
|
78
|
Huang HM, Kuo HK, Fang PC, Lin HF, Lin PW, Lin SA. The effects of CAM vision stimulator for bilateral amblyopia of different etiologies. CHANG GUNG MEDICAL JOURNAL 2008; 31:592-598. [PMID: 19241899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
BACKGROUND To evaluate the association between bilateral amblyopia and the effects of CAM vision stimulator. METHODS This retrospective study was carried out between January 1994 and July 2004. The 105 children enrolled were all younger than 7 years old and had bilateral amblyopia. All children wearing full-correction glasses regularly received CAM vision stimulation once per week. The patients' age, initial best corrected visual acuity (BCVA), final BCVA, and the number of CAM sessions needed to achieve a visual acuity (VA) > or = 0.8 were recorded. RESULTS The major cause of bilateral amblyopia was refractive error. In this study, the types of refractive error were classified as astigmatism (> 2.0D, 61 cases), hyperopia (> 3.0D, 17 cases), and myopia (> 4.0D, 12 cases). The myopic group showed significantly poorer visual outcomes than the other children after CAM treatment (p < 0.05). However, older children patients had better initial BCVA, and the hyperopic patients had the better outcomes in this study. CONCLUSIONS CAM treatment for bilateral amblyopia can achieve satisfactory improvement in 3 months in most instances. The myopic group and children younger than 4 years old had worse visual outcomes after CAM treatment.
Collapse
|
79
|
Sergienko NM, Kondratenko YN, Tutchenko NN. Depth of focus in pseudophakic eyes. Graefes Arch Clin Exp Ophthalmol 2008; 246:1623-7. [PMID: 18766370 DOI: 10.1007/s00417-008-0923-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2008] [Revised: 07/23/2008] [Accepted: 07/26/2008] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To assess depth of field/depth of focus in pseudophakic eyes as function of visual acuity. SETTING Department of ophthalmology of National Medical Academy of Postgraduate Education. METHODS Forty-three pseudophakic eyes of 43 patients after implantation in the capsular bag of monofocal posterior chamber IOLs were examined. All patients had visual acuities at least 20/20 for distance. Visual acuity was examined by charts consisting the Landolt's rings under defined constant illumination within distance from 3 m to 20 cm from patients' eyes at various distances with difference of 10 cm (29 measurements). Depth of field was calculated in diopters. RESULTS The mean value of the depth of field in pseudophakic eyes with pupil diameter of 3 +/- 0.3 mm was as follows: 1.12 D for visual acuity 20/20, 0.62 D for visual acuity 20/13, and 0.47 D for visual acuity 20/10. CONCLUSIONS Depth of focus correlates to normal levels of visual acuity. The higher the visual acuity, the lower the depth of focus. The ability of clear vision due to depth of focus-pseudoaccommodation is passive function. Separating the pseudoaccommodation from artificial accommodation in eyes with accommodative IOLs requires strict standardization of methodology especially regarding diameter of pupil, size of test objects, and level of illumination.
Collapse
|
80
|
Rojo A, París E. [Instruments of the Saracíbar Museum (I.O.B.A.). The Placido's disc]. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2008; 83:335-336. [PMID: 18464186 DOI: 10.4321/s0365-66912008000500012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
|
81
|
Durán-de-la-Colina JA. [The consumist ophthalmologist]. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2008; 83:145-146. [PMID: 18311670 DOI: 10.4321/s0365-66912008000300001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
|
82
|
Chong YY, Kosmin A, Barampouti F, Kodati S. Bacterial flora on slit lamps. ANNALS OF OPHTHALMOLOGY (SKOKIE, ILL.) 2008; 40:137-140. [PMID: 19230349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The slit lamp can be a source of cross infection in the clinic setting. We identified the bacteria flora on slit lamps and determined the risk of transmission to patients. Frequent cleaning of the slit lamp especially after treating infected cases can decrease the transmission of organisms.
Collapse
|
83
|
Bakuridze A, Shengelia D, Kurdiani N, Mikaia G, Karanadze N. [Development of the technology of the substance of davikol and standardization]. GEORGIAN MEDICAL NEWS 2008:43-47. [PMID: 18323593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Among wide assortment of pharmaceutical remedies, that use modern medicine as a weapon against different diseases, special place belongs to the ophthalmic pharmaceutical forms, and their development presents independent branch of pharmaceutical technology. Recently, as a reason of various diseases and among them ophthalmic problems, is considered free radicals and reactions with their participation. Protection of the organism from such diseases presents a main goal of antioxidant system. Nowadays, special attention is paid to the natural antioxidants. On the basis of the natural honey technology of eye drops davikol with antioxidant activity have been developed. The objective of our study has been the development of the substance of prolonged pharmaceutical dosage form davikol - eye ophthalmic drops and its standardization. The qualitative and quantitative methods were developed. It is concluded that the optimal method of drying of davikol is sublimation. Dry powder (active substance) davikol was obtained; quality characteristics were identified.
Collapse
|
84
|
Ventura L, Riul C, Sousa SJDFE. Optical projection mires for measurements of the radii of curvature of the cornea in biomicroscopes. APPLIED OPTICS 2007; 46:7155-7161. [PMID: 17932523 DOI: 10.1364/ao.46.007155] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Keratometry is currently achieved by projecting a circular mire onto the patient's cornea and analyzing the size and shape of its reflected image. The projection mires are decisive for the precision of the measurement. We have previously developed a keratometric module for slit lamps, and the development of four projection mires are presented. Mire 1 is composed of optical fibers and electrical cables; Mire 2, 48 LEDs; Mire 3, optical fibers and no electrical cables; and Mire 4, mechanical parts--cable free. Mires 2-4 provide accurate keratometry measurements at slit lamps. Mire 4 is the most adequate for the clinical environment.
Collapse
|
85
|
Christoff A, Guyton DL. How to measure slab-off and reverse slab prism in spectacle lenses. J AAPOS 2007; 11:414-5. [PMID: 17280851 DOI: 10.1016/j.jaapos.2006.11.109] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2006] [Revised: 11/06/2006] [Accepted: 11/06/2006] [Indexed: 10/23/2022]
Abstract
It is well known that new spectacle lenses for the correction of anisometropia can induce diplopia with reading. The difference in the powers of the lenses induces a net prismatic effect that can cause double vision through off-center areas of the lenses. This is particularly bothersome when patients try to read, often noting vertical double vision in attempted downgaze, especially through multifocal add segments. This induced prismatic effect can be compensated at one level of downgaze by the use of slab-off or reverse slab prism. Typically the slab-off correction is ground into the stronger minus, or weaker plus lens. Reverse slab is ground into the weaker minus, or stronger plus, lens. Unfortunately, determining the amount of slab-off prism already incorporated into spectacle lenses is nonintuitive and inconvenient. This usually requires the use of a lens clock, which is not widely accessible to many ophthalmology practices. A simple technique, described in the past but poorly known, is illustrated here for quickly measuring slab-off and reverse slab prism prescription lenses in the clinic with a common manual lens meter.
Collapse
|
86
|
Matsumoto Y, Dogru M, Goto E, Ishida R, Kojima T, Onguchi T, Yagi Y, Shimazaki J, Tsubota K. Efficacy of a new warm moist air device on tear functions of patients with simple meibomian gland dysfunction. Cornea 2007; 25:644-50. [PMID: 17077654 DOI: 10.1097/01.ico.0000208822.70732.25] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of an original warm moist air device on tear functions and ocular surface of patients with simple meibomian gland dysfunction (MGD). METHODS Fifteen patients with simple MGD and 20 healthy volunteers were recruited in an initial prospective interventional clinical trial to evaluate the safety and short-term effects of the warm moist air device. The device was applied to the eyes of the subjects for 10 minutes. Temperatures of the eye lids and corneas were measured with an infrared thermometer. Symptoms of ocular fatigue were scored using visual analog scales (VASs). Schirmer test, tear film break-up time (BUT), DR-1 tear film lipid layer interferometry, fluorescein staining, and rose bengal staining were also performed before and after the application of the eye steamer. After the initial study, another 2-week prospective clinical trial was carried out in 10 patients with MGD who received the warm moist air treatment. Ten other patients were also recruited and received warm compress treatment with hot towels for 2 weeks to evaluate the long-term effects of the warm moist air device and the warm compresses on tear film lipid layer thickness and ocular surface health. The warm moist air device and the warm compresses were applied for 10 minutes twice a day. The changes in VAS scores for symptoms, BUT values, fluorescein, and rose bengal staining scores were examined before and after each treatment during the second trial. RESULTS VAS scores of ocular fatigue improved significantly with short- and long-term applications of the warm moist air device in both studies. The mean corneal surface and eye lid temperatures showed significant elevation within safe limits 10 minutes after the moist air application. The mean BUT prolonged significantly in the patients receiving warm moist air applications but did not change significantly in those treated with warm compresses. DR-1 tear film lipid layer interference showed evidence of lipid expression in the patients and controls, with thickening of the tear film lipid layer after 10 minutes of warm moist air device use. In the 2-week trial, tear film lipid layer thickness increased in both warm moist air device and warm compress groups, with a greater extent of increase in the warm moist air device group. CONCLUSION Warm moist air device use provided symptomatic relief of ocular fatigue and improvement of tear stability in patients with MGD. The new warm moist air device seems to be a safe and promising alternative in the treatment of MGD.
Collapse
|
87
|
Saleh GM, Gauba V, Mitra A, Beckingsale AB, Aziz O, Allen RJ. Electromagnetic interference by cellular phones with ophthalmic equipment. ACTA ACUST UNITED AC 2007; 85:345-6. [PMID: 17488470 DOI: 10.1111/j.1600-0420.2006.00837.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
88
|
Delori FC, Webb RH, Sliney DH. Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2007; 24:1250-65. [PMID: 17429471 DOI: 10.1364/josaa.24.001250] [Citation(s) in RCA: 293] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
After discussing the rationale and assumptions of the ANSI Z136.1-2000 Standard for protection of the human eye from laser exposure, we present the concise formulation of the exposure limits expressed as maximum permissible radiant exposure (in J/cm(2)) for light overfilling the pupil. We then translate the Standard to a form that is more practical for typical ophthalmic devices or in vision research situations, implementing the special qualifications of the Standard. The safety limits are then expressed as radiant power (watts) entering the pupil of the eye. Exposure by repetitive pulses is also addressed, as this is frequently employed in ophthalmic applications. Examples are given that will familiarize potential users with this format.
Collapse
|
89
|
Saleh GM, Tsesmetzoglou E, Tossounis CM, McLean CJ. A novel approach to lacrimal sac dissection in dacryocystorhinostomy. Ophthalmic Plast Reconstr Surg 2007; 23:171-2. [PMID: 17413647 DOI: 10.1097/iop.0b013e3180331393] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The use of membrane-peeling vitreoretinal forceps to facilitate lacrimal sac dissection in external dacryocystorhinostomy is demonstrated. The closed vitreoretinal forceps are advanced via the upper punctum and canaliculus, through to the lacrimal sac. They are then opened maximally providing two points of elevation. This maneuver allows for easier identification of the plane of dissection during lacrimal flap creation. It is especially useful with complex anatomy and for junior trainees in helping to orient the dissection. No tissue or instrument damage has been noted, and because many ophthalmic units have a vitreoretinal service, the forceps may be readily available at no extra cost.
Collapse
|
90
|
Abstract
PURPOSE To describe a new technique for the insertion of a bandage contact lens with the help of sterile Minims. METHODS The bandage contact lens is picked up with the nozzle of the Minims by suction. The lens is then taken to the patient, placed on the cornea, and released by breaking the vacuum. RESULTS Examination of the contact lens under the microscope after insertion showed no damage. CONCLUSIONS Insertion of a bandage contact lens with Minims is a nontouch, inexpensive, easy, and patient-friendly method. It can reduce the risk of infection in already compromised eyes.
Collapse
|
91
|
Abstract
This study presents a web-based tool that can be used to assist in identification of unknown individuals using spectacle prescriptions. Currently, when lens prescriptions are used in forensic identifications, investigators are constrained to a simple "match" or "no-match" judgment with an antemortem prescription. It is not possible to evaluate the strength of the conclusion, or rather, the potential or real error rates associated with the conclusion. Three databases totaling over 385,000 individual prescriptions are utilized in this study to allow forensic analysts to easily determine the strength of individuation of a spectacle match to antemortem records by calculating the frequency at which the observed prescription occurs in various U.S. populations. Optical refractive errors are explained, potential states and combinations of refractive errors are described, measuring lens corrections is discussed, and a detailed description of the databases is presented. The practical application of this system is demonstrated using two recent forensic identifications. This research provides a valuable personal identification tool that can be used in cases where eyeglass portions are recovered in forensic contexts.
Collapse
|
92
|
Knox Cartwright NE, Tole DM, Haynes RJ, Males JJ, Dick AD, Mayer EJ. Recovery from macular phototoxicity after corneal triple procedure. Cornea 2007; 26:102-4. [PMID: 17198023 DOI: 10.1097/01.ico.0000240102.51852.5a] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE Visual recovery from macular phototoxicity in 2 cases after prolonged exposure to operating microscope light from uncomplicated corneal triple-procedure surgery. Recovery is discussed in the context of repair and regeneration. METHODS Retrospective case reports. RESULTS Immediately postoperatively, both patients reported positive scotomata and were found to have macular retinal pigment epithelial depigmentation. In 1 case, the fovea was involved. By 6 to 12 months, the scotomata had disappeared despite large areas of retinal pigment epithelial hyperpigmentation remaining. CONCLUSION Recovery from macular phototoxicity occurs, although the mechanism remains unclear. Positive scotomata in these cases resolved over several months. The time scale of recovery was consistent with the time required for cellular replacement and possible differentiation from neural progenitor cells.
Collapse
|
93
|
Fankhauser F. Postoperative follow up by dynamic light scattering: detection of inflammatory molecular changes in the cornea, the vitreous and the lens. Technol Health Care 2007; 15:247-58. [PMID: 17673834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
OBJECTIVE To detect post-op molecular changes and inflammatory processes by dynamic light scattering (DLS) in eye segments. To develop DLS parameters which are appropriate for the control of post-op course after ophthalmologic surgery. METHODS, DESIGN: Three new DLS devices were tested in different post-op clinical settings such as pseudoexfoliation syndrome (PEX), cataract surgery and retinal surgery. In a second step DLS was used to detect molecular changes in the cornea of 6 patients after photo refractive keratectomy (PRK) and 16 patients after photo astigmatic refractive keratectomy (PARK). RESULTS In PEX-patients cataract surgery changed the DLS signals of the anterior chamber and the lens in a specific way compared to the pre-op situation. Cataract patients without PEX had more scattering particles post-op and retinal surgery modified the DLS signal of the vitreous. Furthermore it was shown that the length of the corneal scattering vector l correlated with the process of the corneal wound healing after PARK. One and three months after surgery the lengths of the scattering vectors had increased significantly but returned to pre-op values twelve months post-op. DISCUSSION The post-op transparency of eye segments such as the cornea, the vitreous and the anterior chamber depends primarily on the wound healing mechanisms. DLS seems to be a suitable method to control the corneal recovery after refractive surgery. CONCLUSIONS The length of the scattering vector l correlates well with the wound healing after refractive surgery. However DLS-signals seem to contain information about the molecular composition of tissue too. Therefore further research is needed to refine the interpretation of the DLS signals.
Collapse
|
94
|
|
95
|
Kumar S. Nanophthalmology: new frontier in fighting blindness? Eye (Lond) 2006; 20:1455-6. [PMID: 16557285 DOI: 10.1038/sj.eye.6702333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
|
96
|
Phiri R, Keeffe JE, Harper CA, Taylor HR. Comparative study of the polaroid and digital non-mydriatic cameras in the detection of referrable diabetic retinopathy in Australia. Diabet Med 2006; 23:867-72. [PMID: 16911624 DOI: 10.1111/j.1464-5491.2006.01824.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
AIM To show that the non-mydriatic retinal camera (NMRC) using polaroid film is as effective as the NMRC using digital imaging in detecting referrable retinopathy. METHODS A series of patients with diabetes attending the eye out-patients department at the Royal Victorian Eye and Ear Hospital had single-field non-mydriatic fundus photographs taken using first a digital and then a polaroid camera. Dilated 30 degrees seven-field stereo fundus photographs were then taken of each eye as the gold standard. The photographs were graded in a masked fashion. Retinopathy levels were defined using the simplified Wisconsin Grading system. We used the kappa statistics for inter-reader and intrareader agreement and the generalized linear model to derive the odds ratio. RESULTS There were 196 participants giving 325 undilated retinal photographs. Of these participants 111 (57%) were males. The mean age of the patients was 68.8 years. There were 298 eyes with all three sets of photographs from 154 patients. The digital NMRC had a sensitivity of 86.2%[95% confidence interval (CI) 65.8, 95.3], whilst the polaroid NMRC had a sensitivity of 84.1% (95% CI 65.5, 93.7). The specificities of the two cameras were identical at 71.2% (95% CI 58.8, 81.1). There was no difference in the ability of the polaroid and digital camera to detect referrable retinopathy (odds ratio 1.06, 95% CI 0.80, 1.40, P = 0.68). CONCLUSION This study suggests that non-mydriatic retinal photography using polaroid film is as effective as digital imaging in the detection of referrable retinopathy in countries such as the USA and Australia or others that use the same criterion for referral.
Collapse
|
97
|
Mitra A, Saleh GM. The issue of mobile phone use around ophthalmic equipments. Eye (Lond) 2006; 21:251-2. [PMID: 16778820 DOI: 10.1038/sj.eye.6702482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
98
|
Zingler VC, Kryvoshey D, Schneider E, Glasauer S, Brandt T, Strupp M. A clinical test of otolith function: static ocular counterroll with passive head tilt. Neuroreport 2006; 17:611-5. [PMID: 16603921 DOI: 10.1097/00001756-200604240-00011] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
When roll-tilted around the naso-occipital axis, humans exhibit compensatory torsional rotation of the eyes in the opposite direction owing to the torsional vestibulo-ocular reflex. In the static condition (sustained head roll), the utricles act as responsible sensors for 'static ocular counterroll'. Contributions of cervico-ocular reflexes remain unknown. To find an easy, clinically useful test of utricular function, we induced ocular counterroll in 10 healthy study participants (two men, mean age 27+/-2 years) under three stimulation conditions (active/passive head tilt and passive whole body tilt in roll plane), used three-dimensional video-oculography to measure it, and compared values. Active head-tilt-induced ocular counterroll varied most and was thus less reliable than passive head and body tilt-induced ocular counterroll. Utricular function can thus be tested simply by measuring passive head tilt with video-oculography.
Collapse
|
99
|
Shi MG, Wang L. [Design of a quantitative keratoscope used for ocular microsurgery]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2006; 42:263-6. [PMID: 16643762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
A new quantitative keratoscope used specially for ocular microsurgery to measure corneal astigmatism is reported. A combined cylinder-lens, which power can be changed by rotating lens in anti-direction equally, was designed according to the principal of the crossing cylinder lens. The axis direction is fixed when the lens is rotated. The corneal astigmatism can be measured by changing the power of the combined lens to adjust the corneal ring images. The keratoscope could be used to measure the corneal astigmatism quantitatively specially for ocular microsurgery. At the work-distance of 0.025 m, the maximum power of measured astigmatism was up to 8.50 D. The error of the measurement was less than 0.20 D. The keratoscope is a portable lens to be used easily during the ocular microsurgery. The reporting keratoscope is a simple combined cylinder-lens that can be used to measure corneal astigmatism, including the power and the axis of astigmatism, easily during ocular microsurgery.
Collapse
|
100
|
Doble N. High-resolution, in vivo retinal imaging using adaptive optics and its future role in ophthalmology. Expert Rev Med Devices 2006; 2:205-16. [PMID: 16293057 DOI: 10.1586/17434440.2.2.205] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Until recently it was impossible to fully realize the optical resolution afforded by the human eye due to the inherent optical aberrations. These aberrations limit the ability to see fine structure in the retinal layers and visual perception of the outside world. A conventional spectacle or contact lens refraction only provides a static amelioration of the lowest order aberrations, namely defocus and astigmatism. In addition, all of these distortions are constantly evolving due to changes in accommodation and head/eye movements. The technique of adaptive optics not only corrects all of the static spatial modes but also measures and corrects any dynamic changes. Such systems have allowed for routine in vivo cellular imaging, the classification of individual photoreceptor cells and have enabled psychophysical testing of human visual function at the neural level. This review introduces the principle of adaptive optics and the key hardware required to implement such a scheme. The integration of adaptive optics into different imaging modalities is presented along with descriptions of current systems in use today and the experimental results obtained to date. Finally, the review concludes by discussing future technology and gives the author's prediction of how the field will evolve over the coming years.
Collapse
|