1
|
Panditharatne SP, Imali DY, Perera ECJ, Perera LHR, Hettiarachchi GHCM, Kaumal MN. Anodized CuO-based reusable non-enzymatic glucose sensor as an alternative method for the analysis of pharmaceutical glucose infusions: a cyclic voltammetric approach. ANAL SCI 2024; 40:1475-1487. [PMID: 38727930 DOI: 10.1007/s44211-024-00585-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Accepted: 04/22/2024] [Indexed: 07/26/2024]
Abstract
Analyzing pharmaceutical products is a quality control requirement in a production facility. This study presents a CuO electrode-based reusable non-enzymatic sensor as an alternative method for rapid analysis of glucose levels in glucose infusions. CuO is extensively employed as an electrode material in non-enzymatic glucose sensors. Conventionally, these electrodes are fabricated using chemical synthesis of CuO followed by immobilization to the electrode substrate. In contrast, here, Cu metal was mechanically modified to create a grooved surface, followed by electrochemical anodization and subsequent annealing process to grow a seamless CuO layer in situ with enhanced catalytic activity. The morphology of the electrodes was characterized using scanning electron microscopy (SEM) and X-ray diffractometry (XRD). The direct electrocatalytic activity of the developed CuO-modified electrode towards glucose oxidation in alkaline media was investigated by cyclic voltammetry in detail. The CuO-modified electrode commenced the oxidation process around 0.10 V vs. Ag pseudo-reference electrode, demonstrating a significant reduction in the overvoltage for glucose oxidation compared to the bare Cu electrode. The sensor is capable of detecting glucose at low oxidation potentials such as 0.2 V with a sensitivity value of 0.37 µA ppm-1, a wide linear range (80-2300 ppm), limit of quantification (LOQ) of 1 ppm, greater repeatability, 1% precision, 3% bias, a short response time (80 s), good reproducibility and excellent reusability (196 consecutive attempts). The enhanced performance and cost-effectiveness make this sensor a promising alternative method for product analysis in glucose injection solutions.
Collapse
Affiliation(s)
| | - D Yureka Imali
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| | - E Chavin J Perera
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| | - L Hasini R Perera
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka.
| | | | - M N Kaumal
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| |
Collapse
|
2
|
Mim JJ, Hasan M, Chowdhury MS, Ghosh J, Mobarak MH, Khanom F, Hossain N. A comprehensive review on the biomedical frontiers of nanowire applications. Heliyon 2024; 10:e29244. [PMID: 38628721 PMCID: PMC11016983 DOI: 10.1016/j.heliyon.2024.e29244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 04/03/2024] [Accepted: 04/03/2024] [Indexed: 04/19/2024] Open
Abstract
This comprehensive review examines the immense capacity of nanowires, nanostructures characterized by unbounded dimensions, to profoundly transform the field of biomedicine. Nanowires, which are created by combining several materials using techniques such as electrospinning and vapor deposition, possess distinct mechanical, optical, and electrical properties. As a result, they are well-suited for use in nanoscale electronic devices, drug delivery systems, chemical sensors, and other applications. The utilization of techniques such as the vapor-liquid-solid (VLS) approach and template-assisted approaches enables the achievement of precision in synthesis. This precision allows for the customization of characteristics, which in turn enables the capability of intracellular sensing and accurate drug administration. Nanowires exhibit potential in biomedical imaging, neural interfacing, and tissue engineering, despite obstacles related to biocompatibility and scalable manufacturing. They possess multifunctional capabilities that have the potential to greatly influence the intersection of nanotechnology and healthcare. Surmounting present obstacles has the potential to unleash the complete capabilities of nanowires, leading to significant improvements in diagnostics, biosensing, regenerative medicine, and next-generation point-of-care medicines.
Collapse
Affiliation(s)
- Juhi Jannat Mim
- Department of Mechanical Engineering, IUBAT-International University of Business Agriculture and Technology, Bangladesh
| | - Mehedi Hasan
- Department of Mechanical Engineering, IUBAT-International University of Business Agriculture and Technology, Bangladesh
| | - Md Shakil Chowdhury
- Department of Mechanical Engineering, IUBAT-International University of Business Agriculture and Technology, Bangladesh
| | - Jubaraz Ghosh
- Department of Mechanical Engineering, IUBAT-International University of Business Agriculture and Technology, Bangladesh
| | - Md Hosne Mobarak
- Department of Mechanical Engineering, IUBAT-International University of Business Agriculture and Technology, Bangladesh
| | - Fahmida Khanom
- Department of Mechanical Engineering, IUBAT-International University of Business Agriculture and Technology, Bangladesh
| | - Nayem Hossain
- Department of Mechanical Engineering, IUBAT-International University of Business Agriculture and Technology, Bangladesh
| |
Collapse
|
3
|
Chang F, Wang D, Pu Z, Chen J, Tan J. Electrochemical sensing performance of two CuO nanomaterial-modified dual-working electrodes. RSC Adv 2024; 14:14194-14201. [PMID: 38686285 PMCID: PMC11057454 DOI: 10.1039/d4ra01356e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 04/16/2024] [Indexed: 05/02/2024] Open
Abstract
Two CuO nanostructures, namely, nanospheres (CuONSs) and nanochains (CuONCs) with different shapes but similar diameters, were synthesized and characterized. With these two nanomaterials as electrode modifiers, a systematic comparative study was conducted to examine their electrochemical sensing of catechol (CT) using a dual-working electrode system. The results suggest that for CuONS- and CuONC-modified glassy carbon electrodes, the electrode process for the CT redox is diffusion-controlled, and the modification amount and electrolyte pH have a similar effect on the response. However, the CuONCs showed a higher peak current and lower peak potential, as well as a lower detection limit for the electrochemical oxidation of CT. This is explained by the lower charge transfer impedance and higher electroactive surface area of the CuONCs. Notably, an unexpected peak appeared in the cyclic voltammograms when the pH was <4 for the CuONCs and <3 for the CuONSs. For this phenomenon, UV-Vis spectra, zeta potential, and size distribution experiments demonstrated changes in the two CuO nanostructures at lower pH, illustrating that CuONSs can tolerate a higher pH as compared to CuONCs. The multiple comparisons between the two nanomaterials presented here can provide references for the selection of electrochemical sensing materials.
Collapse
Affiliation(s)
- Fengxia Chang
- School of Chemistry and Environment, Southwest Minzu University Chengdu P.R. China
| | - Dan Wang
- School of Chemistry and Environment, Southwest Minzu University Chengdu P.R. China
| | - Zixian Pu
- School of Chemistry and Environment, Southwest Minzu University Chengdu P.R. China
| | - Jinhang Chen
- School of Chemistry and Environment, Southwest Minzu University Chengdu P.R. China
| | - Jiong Tan
- School of Chemistry and Environment, Southwest Minzu University Chengdu P.R. China
| |
Collapse
|
4
|
Yao W, He H, Wang F. CTAB-Modulated Electroplating of Copper Micropillar Arrays for Non-Enzymatic Glucose Sensing with Improved Sensitivity. SENSORS (BASEL, SWITZERLAND) 2024; 24:1603. [PMID: 38475139 DOI: 10.3390/s24051603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 01/05/2024] [Accepted: 01/07/2024] [Indexed: 03/14/2024]
Abstract
Micropillar array electrodes represent a promising avenue for enhancing detection sensitivity and response current. However, existing methods for depositing electrode materials on micropillar arrays often result in uneven distribution, with the thin sidewall layer being less conductive and prone to corrosion. In addressing this issue, this study introduces electroplating to enhance the copper layer on the sidewall of micropillar array electrodes. These electrodes, fabricated through standard microelectronics processes and electroplating, are proposed for non-enzymatic glucose detection, with the copper layer deposited via electroplating significantly enhancing sensitivity. Initially, the impact of cetyltrimethylammonium bromide (CTAB) concentration as an inhibitor on the surface morphology and sensitivity of the plated layer was investigated. It was discovered that CTAB could decrease surface roughness, hinder the development of large and coarse grains, generate small particles, and boost sensitivity. Compared to the uncoated electrode and plating without CTAB, sensitivity was elevated by a factor of 1.66 and 1.62, respectively. Subsequently, the alterations in plating morphology and detection performance within a range of 0.3 ASD to 3 ASD were examined. Sensitivity demonstrated a tendency to increase initially and then decrease. The electrode plated at 0.75 ASD achieved a maximum sensitivity of 3314 μA·mM-1·cm-2 and a detection limit of 15.9 μM. Furthermore, a potential mechanism explaining the impact of different morphology on detection performance due to CTAB and current density was discussed. It was believed that the presented effective strategy to enhance the sensitivity of micropillar array electrodes for glucose detection would promote the related biomedical detection applications.
Collapse
Affiliation(s)
- Wenhao Yao
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Hu He
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| | - Fuliang Wang
- State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
| |
Collapse
|
5
|
Selvi Gopal T, James JT, Gunaseelan B, Ramesh K, Raghavan V, Malathi A CJ, Amarnath K, Kumar VG, Rajasekaran SJ, Pandiaraj S, MR M, Pitchaimuthu S, Abeykoon C, Alodhayb AN, Grace AN. MXene-Embedded Porous Carbon-Based Cu 2O Nanocomposites for Non-Enzymatic Glucose Sensors. ACS OMEGA 2024; 9:8448-8456. [PMID: 38405472 PMCID: PMC10882672 DOI: 10.1021/acsomega.3c09659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 01/25/2024] [Accepted: 01/31/2024] [Indexed: 02/27/2024]
Abstract
This work explores the use of MXene-embedded porous carbon-based Cu2O nanocomposite (Cu2O/M/AC) as a sensing material for the electrochemical sensing of glucose. The composite was prepared using the coprecipitation method and further analyzed for its morphological and structural characteristics. The highly porous scaffold of activated (porous) carbon facilitated the incorporation of MXene and copper oxide inside the pores and also acted as a medium for charge transfer. In the Cu2O/M/AC composite, MXene and Cu2O influence the sensing parameters, which were confirmed using electrochemical techniques such as cyclic voltammetry, electrochemical impedance spectroscopy, and amperometric analysis. The prepared composite shows two sets of linear ranges for glucose with a limit of detection (LOD) of 1.96 μM. The linear range was found to be 0.004 to 13.3 mM and 15.3 to 28.4 mM, with sensitivity values of 430.3 and 240.5 μA mM-1 cm-2, respectively. These materials suggest that the prepared Cu2O/M/AC nanocomposite can be utilized as a sensing material for non-enzymatic glucose sensors.
Collapse
Affiliation(s)
- Tami Selvi Gopal
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Jaimson T. James
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Bharath Gunaseelan
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Karthikeyan Ramesh
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Vimala Raghavan
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Christina Josephine Malathi A
- Department
of Communication Engineering, School of Electronics Engineering (SENSE), Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| | - K. Amarnath
- Department
of Chemistry and Centre for Ocean Research, Sathyabama Institute of Science and Technology, Chennai 600119, India
| | - V. Ganesh Kumar
- Department
of Chemistry and Centre for Ocean Research, Sathyabama Institute of Science and Technology, Chennai 600119, India
| | | | - Saravanan Pandiaraj
- Department
of Self-Development Skills, King Saud University, Riyadh 11451, Saudi Arabia
| | | | - Sudhagar Pitchaimuthu
- Research
Centre for Carbon Solutions, Institute of Mechanical, Processing and
Energy Engineering, School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, U.K.
| | - Chamil Abeykoon
- Northwest
Composites Centre, Aerospace Research Institute, and Department of
Materials, Faculty of Science and Engineering, The University of Manchester, Oxford Road, Manchester M13 9PL, U.K.
| | - Abdullah N. Alodhayb
- Department
of Physics and Astronomy, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| | - Andrews Nirmala Grace
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| |
Collapse
|
6
|
Alam MM, Howlader MMR. High performance nonenzymatic electrochemical sensors via thermally grown Cu native oxides (CuNOx) towards sweat glucose monitoring. Analyst 2024; 149:712-728. [PMID: 37755066 DOI: 10.1039/d3an01153d] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/28/2023]
Abstract
Diabetes, which is the seventh leading cause of death globally, necessitates real-time blood glucose monitoring, a process that is often invasive. A promising alternative is sweat glucose monitoring, which typically uses transition metals and their oxide nanomaterials as sensors. Despite their excellent surface-to-volume ratio, these materials have some drawbacks, including poor conductivity, structural collapse, and aggregation. As a result, selecting highly electroconductive materials and optimizing their nanostructures is critical. In this work, we developed a high-performance, low-cost, nonenzymatic sensor for sweat glucose detection, using the thermally grown native oxide of copper (CuNOx). By heating Cu foil at 160, 250, and 280 °C, we grew a native oxide layer of approximately 140 nm cupric oxide (CuO), which is excellent for glucose electrocatalysis. Using cyclic voltammetry, we found that our CuNOx sensors prepared at 280 °C exhibited a sensitivity of 1795 μA mM-1 cm-2, a linear range up to the desired limit of 1.00 mM for sweat glucose with excellent linearity (R2 = 0.9844), and a lower limit of detection of 135.39 μM. For glucose sensing, the redox couple Cu(II)/Cu(III) oxidizes glucose to gluconolactone and subsequently to gluconic acid, producing an oxidation current in an alkaline environment. Our sensors showed excellent repeatability and stability (remaining stable for over a year) with a relative standard deviation (RSD) of 2.48% and 4.17%, respectively, for 1 mM glucose. The selectivity, when tested with common interferants found in human sweat and blood, showed an RSD of 4.32%. We hope that the electrocatalytic efficacy of the thermally grown CuNOx sensors for glucose sensing can introduce new avenues in the fabrication of sweat glucose sensors.
Collapse
Affiliation(s)
- Maksud M Alam
- Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4K1, Canada.
| | - Matiar M R Howlader
- Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4K1, Canada.
| |
Collapse
|
7
|
Thi LLD, Ho TH, Vu TV, Nguyen DLT, Tran MX, Rhim SH, Nguyen CD. P-incorporated CuO/Cu 2S heteronanorods as efficient electrocatalysts for the glucose oxidation reaction toward highly sensitive and selective glucose sensing. Phys Chem Chem Phys 2023; 26:249-260. [PMID: 38054775 DOI: 10.1039/d3cp04095j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
Currently, tremendous efforts have been made to explore efficient glucose oxidation electrocatalysts for enzymeless glucose sensors to meet the urgent demands for accurate and fast detection of glucose in the fields of health care and environmental monitoring. In this work, an advanced nanostructured material based on the well-aligned CuO/Cu2S heteronanorods incorporated with P atoms is successfully synthesized on a copper substrate. The as-synthesized material shows high catalytic behavior accompanied by outstanding electrical conductivity. This, combined with the unique morphology of unstacked nanorod arrays, which endow the entire material with a greater number of exposed active sites, make the proposed material act as a highly efficient electrocatalyst for the glucose oxidation reaction. Density functional theory calculations demonstrate that P doping endows P-doped CuO/Cu2S with excellent electrical conductivity and glucose adsorption capability, significantly improving its catalytic performance. As a result, a non-enzymatic glucose sensor fabricated based on our proposed material exhibits a broad linear detection range (0.02-8.2 mM) and a low detection limit (0.95 μM) with a high sensitivity of 2.68 mA mM-1 cm-2 and excellent selectivity.
Collapse
Affiliation(s)
- L L D Thi
- Laboratory for Advanced Nanomaterials and Sustainable Energy Technologies, Institute for Computational Science and Artificial Intelligence, Van Lang University, Ho Chi Minh City, Vietnam.
- Faculty of Applied Technology, School of Technology, Van Lang University, Ho Chi Minh City, Vietnam
| | - Thi H Ho
- Laboratory for Computational Physics, Institute for Computational Science and Artificial Intelligence, Van Lang University, Ho Chi Minh City, Vietnam
- Faculty of Mechanical - Electrical and Computer Engineering, School of Technology, Van Lang University, Ho Chi Minh City, Vietnam
| | - Tuan V Vu
- Laboratory for Computational Physics, Institute for Computational Science and Artificial Intelligence, Van Lang University, Ho Chi Minh City, Vietnam
- Faculty of Mechanical - Electrical and Computer Engineering, School of Technology, Van Lang University, Ho Chi Minh City, Vietnam
| | - Dang L T Nguyen
- Laboratory for Advanced Nanomaterials and Sustainable Energy Technologies, Institute for Computational Science and Artificial Intelligence, Van Lang University, Ho Chi Minh City, Vietnam.
- Faculty of Applied Technology, School of Technology, Van Lang University, Ho Chi Minh City, Vietnam
| | - Minh Xuan Tran
- Laboratory for Advanced Nanomaterials and Sustainable Energy Technologies, Institute for Computational Science and Artificial Intelligence, Van Lang University, Ho Chi Minh City, Vietnam.
- Faculty of Applied Technology, School of Technology, Van Lang University, Ho Chi Minh City, Vietnam
| | - Sonny H Rhim
- Department of Physics and Energy Harvest Storage Research Center, University of Ulsan, Ulsan, 44610, Republic of Korea
| | - C-D Nguyen
- The University of Danang - University of Science and Education, Danang 550000, Vietnam.
| |
Collapse
|
8
|
Hassan IU. Diabetes Management by Fourth-Generation Glucose Sensors Based on Lemon-Extract-Supported CuO Nanoporous Materials. Molecules 2023; 28:6763. [PMID: 37836606 PMCID: PMC10574443 DOI: 10.3390/molecules28196763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 09/11/2023] [Accepted: 09/18/2023] [Indexed: 10/15/2023] Open
Abstract
Diabetes is a major worldwide health issue, impacting millions of people around the globe and putting pressure on healthcare systems. Accurate detection of glucose is critical for efficient diabetes care, because it allows for prompt action to control blood sugar levels and avoid problems. Reliable glucose-sensing devices provide individuals with real-time information, allowing them to make more educated food, medicine, and lifestyle decisions. The progress of glucose sensing holds the key to increasing the quality of life for diabetics and lowering the burden of this prevalent condition. The present investigation addresses the synthesis of a CuO@lemon-extract nanoporous material using the sol-gel process. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to analyze the morphological properties of the composite, which revealed a homogeneous integration of CuO nanoparticles (NPs) on the surface of the matrix. The existence of primarily oxidized copper species, especially CuO, was confirmed by X-ray diffraction spectroscopy (XRD) investigation in combination with energy-dispersive X-ray (EDX) spectroscopy. The CuO@lemon-extract-modified glassy carbon electrode (CuO@lemon-extract GCE) performed well in non-enzymatic electrochemical sensing applications such as differential pulse voltammetry (DPV) and amperometric glucose detection. The electrode achieved a notable sensitivity of 3293 µA mM-1 cm-2 after careful adjustment, with a noticeable detection limit of 0.01 µM (signal-to-noise ratio of 3). The operational range of the electrode was 0.01 µM to 0.2 µM, with potential applied of 0.53 V vs. Ag/AgCl. These findings underscore the CuO@lemon-extract GCE's promise as a robust and reliable platform for electrochemical glucose sensing, promising advances in non-enzymatic glucose sensing (NEGS) techniques.
Collapse
Affiliation(s)
- Israr U Hassan
- Department of Mathematics & Sciences, College of Arts & Applied Sciences, Dhofar University, Salalah PC 211, Oman
| |
Collapse
|
9
|
Ali MY, Knight D, Howlader MMR. Nonenzymatic Electrochemical Glutamate Sensor Using Copper Oxide Nanomaterials and Multiwall Carbon Nanotubes. BIOSENSORS 2023; 13:237. [PMID: 36832003 PMCID: PMC9954524 DOI: 10.3390/bios13020237] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 01/28/2023] [Accepted: 02/03/2023] [Indexed: 05/28/2023]
Abstract
Glutamate is an important neurotransmitter due to its critical role in physiological and pathological processes. While enzymatic electrochemical sensors can selectively detect glutamate, enzymes cause instability of the sensors, thus necessitating the development of enzyme-free glutamate sensors. In this paper, we developed an ultrahigh sensitive nonenzymatic electrochemical glutamate sensor by synthesizing copper oxide (CuO) nanostructures and physically mixing them with multiwall carbon nanotubes (MWCNTs) onto a screen-printed carbon electrode. We comprehensively investigated the sensing mechanism of glutamate; the optimized sensor showed irreversible oxidation of glutamate involving one electron and one proton, and a linear response from 20 μM to 200 μM at pH 7. The limit of detection and sensitivity of the sensor were about 17.5 μM and 8500 μA·mM-1·cm-2, respectively. The enhanced sensing performance is attributed to the synergetic electrochemical activities of CuO nanostructures and MWCNTs. The sensor detected glutamate in whole blood and urine and had minimal interference with common interferents, suggesting its potential for healthcare applications.
Collapse
Affiliation(s)
- Md Younus Ali
- Department of Electrical and Computer Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada
| | - Dorian Knight
- Department of Computing and Software, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada
| | - Matiar M. R. Howlader
- Department of Electrical and Computer Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada
| |
Collapse
|
10
|
Swetha PDP, Nikitha A, Shenoy MM, Shim YB, Prasad KS. Ni/Ni(OH) 2-rGO nanocomposites sensor for the detection of long forgotten mycotoxin, xanthomegnin. Talanta 2023; 253:123953. [PMID: 36179558 DOI: 10.1016/j.talanta.2022.123953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 09/10/2022] [Accepted: 09/17/2022] [Indexed: 12/13/2022]
Abstract
Xanthomegnin, a known fungal toxin, secondary metabolite, and pigment diffuses from the dermatophytes has gained attention as local virulence factor because of the mutagenicity, toxicity, cytocidal, and immunosuppressive properties. Not only as a dermatophyte in skin related disorders, the production of xanthomegnin is implicated as a powerful diagnostic marker in patients suffering from ocular mycoses. Incidentally also attributed to death in livestock's majorly by exposing themselves to food-borne fungi like Aspergillus and Penicillium. The production of xanthomegnin in dermetophytic species Trichophyton rubrum, found commonly in infected skin and nails. In this study nickel/nickel hydroxide nanoparticles decorated reduced graphene oxide (Ni/Ni(OH)2-rGO) modified glassy carbon electrode has been successfully used for non-enzymatic detection of xanthomegnin. The Ni/Ni(OH)2-rGO composites were synthesized through a simple microwave assisted technique with less harmful reducing agent. The UV-visible spectroscopy (UV-vis), X-ray photoelectron spectroscopy (XPS), Scanning electron microscopy - energy dispersive X-ray spectroscopy (SEM-EDS), and electrochemical investigations demonstrated the robust formation of the sensor. The sensor exhibited improved electrochemical properties with enhanced electrochemical active area and excellent electrochemical behavior towards xanthomegnin detection with a limit of detection of 0.12 μM. The selectivity, stability, and analytical recovery studies proved the potential use of the sensor for the detection of xanthomegnin in real samples. Further, the sensor successfully detected xanthomegnin produced by the Trichophyton rubrum, the most common superficial fungus, accounting for at least 60% of all superficial fungal infections in humans. Validation studies showed satisfiable and quantifiable amount of xanthomegnin in comparison with common bench mark UV-Vis studies meant for fungal mycotoxin detection.
Collapse
Affiliation(s)
- P D Priya Swetha
- Nanomaterial Research Laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore, 575 018, India
| | - A Nikitha
- Department of Dermatology,Venereology and Leprosy, Yenepoya Medical College, Deralakatte, Mangalore, 575018, India
| | - M Manjunath Shenoy
- Department of Dermatology,Venereology and Leprosy, Yenepoya Medical College, Deralakatte, Mangalore, 575018, India
| | - Yoon-Bo Shim
- Department of Chemistry and Institute of Biophysio Sensor Technology, Pusan National University, Busan, 46241, Republic of Korea
| | - K Sudhakara Prasad
- Nanomaterial Research Laboratory (NMRL), Nano Division, Yenepoya Research Centre, Yenepoya (Deemed to be University), Deralakatte, Mangalore, 575 018, India; Centre for Nutrition Studies, Yenepoya (Deemed to be University), Deralakatte, Mangalore, 575018, India.
| |
Collapse
|
11
|
Chahrour KM, Ooi PC, Nazeer AA, Al-Hajji LA, Jubu PR, Dee CF, Ahmadipour M, Hamzah AA. CuO/Cu/rGO nanocomposite anodic titania nanotubes for boosted non-enzymatic glucose biosensors. NEW J CHEM 2023. [DOI: 10.1039/d3nj00666b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Abstract
Highly arranged porous anodic titania (TiO2) nanotube arrays (ATNT) were fruitfully fabricated by the anodization of Ti foil in an ammonium fluoride electrolyte.
Collapse
Affiliation(s)
- Khaled M. Chahrour
- Mechanical Engineering Dept., Faculty of Engineering, Karabuk University, 78050, Karabuk, Turkey
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Poh Choon Ooi
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Ahmed Abdel Nazeer
- Nanotechnology and Advanced Materials Program, Energy & Building Research Center, Kuwait Institute for Scientific Research (KISR), P.O. Box 24885, Safat, 13109, Kuwait
- Electrochemistry Laboratory, Physical Chemistry Department, National Research Center, Giza, Egypt
| | - Latifa A. Al-Hajji
- Nanotechnology and Advanced Materials Program, Energy & Building Research Center, Kuwait Institute for Scientific Research (KISR), P.O. Box 24885, Safat, 13109, Kuwait
| | - Peverga R. Jubu
- Department of Physics, University of Agriculture Makurdi (Now Joseph Sarwuan Tarka University Makurdi), P.M.B. 2373, Makurdi, Benue State, Nigeria
| | - Chang Fu Dee
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Mohsen Ahmadipour
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Azrul Azlan Hamzah
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| |
Collapse
|
12
|
Zhao C, Tang X, Zhao J, Cao J, Jiang Z, Qin J. MOF derived core-shell CuO/C with temperature-controlled oxygen-vacancy for real time analysis of glucose. J Nanobiotechnology 2022; 20:507. [PMID: 36456946 PMCID: PMC9714170 DOI: 10.1186/s12951-022-01715-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 11/18/2022] [Indexed: 12/03/2022] Open
Abstract
Introducing oxygen-vacancy into the surface of the non-enzymatic sensor is supposed to be an effective way to improve inherently low catalytic activity and specificity of non-enzymatic sensors. In this work, CuO/C was synthesized at different temperatures using metal-organic frameworks as sacrificial templates to receive additional content of oxygen-vacancy. The product with the highest oxygen vacancy was found at 400 °C (named CuO/C-400 °C), which increased catalytically active sites and enhanced the charge-transfer efficiency. The sensing performance was afterward explored by amperometry under an optimal applied potential at 0.5 V (vs. SCE), presenting a broad detection range from 5.0 µM to 25.325 mM (R2 = 0.9998) with a sensitivity of 244.71 µA mM- 1 cm- 2, and a detection limit of 1 µM. Furthermore, the reliability and selectivity of CuO/C-400 °C sensors were extensively explored in the presence of artificial serum/saliva samples with gradient glucose concentrations. The human blood samples were also detected with high recoveries compared with the clinical Hexokinase method. Hence, the prepared CuO/C-400 °C sensor with a broad detection range and high selectivity can be applied for the diabetes diagnosis ex vivo without further dilution for real-time analysis in practical applications.
Collapse
Affiliation(s)
- Chen Zhao
- grid.24516.340000000123704535Shanghai Tenth People’s Hospital, School of Medicine, Tongji University Cancer Center, Tongji University, Shanghai, 200092 China ,grid.43555.320000 0000 8841 6246School of Medical Technology, School of Life Science, Beijing Institute of Technology, Beijing, 100081 China
| | - Xiaoying Tang
- grid.43555.320000 0000 8841 6246School of Medical Technology, School of Life Science, Beijing Institute of Technology, Beijing, 100081 China
| | - Jinge Zhao
- grid.43555.320000 0000 8841 6246Key Laboratory of Medical Molecule Science and Pharmaceutics Engineering, Ministry of Industry and Information Technology, Key Laboratory of Cluster Science of Ministry of Education, Beijing Key laboratory of Photoelectronic/Electro-photonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing, 100081 People’s Republic of China
| | - Jie Cao
- grid.43555.320000 0000 8841 6246Key Laboratory of Medical Molecule Science and Pharmaceutics Engineering, Ministry of Industry and Information Technology, Key Laboratory of Cluster Science of Ministry of Education, Beijing Key laboratory of Photoelectronic/Electro-photonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing, 100081 People’s Republic of China
| | - Zhenqi Jiang
- grid.43555.320000 0000 8841 6246School of Medical Technology, School of Life Science, Beijing Institute of Technology, Beijing, 100081 China
| | - Jieling Qin
- grid.24516.340000000123704535Shanghai Tenth People’s Hospital, School of Medicine, Tongji University Cancer Center, Tongji University, Shanghai, 200092 China
| |
Collapse
|
13
|
Cao X. CuO Nanowires Fabricated by Thermal Oxidation of Cu Foils towards Electrochemical Detection of Glucose. MICROMACHINES 2022; 13:2010. [PMID: 36422439 PMCID: PMC9692939 DOI: 10.3390/mi13112010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 10/28/2022] [Accepted: 11/15/2022] [Indexed: 06/16/2023]
Abstract
In view of the various stability issues and high cost of enzymatic glucose biosensors, non-enzymatic biosensors have received great attention in recent research and development. Copper oxide (CuO) nanowires (NWs) were fabricated on Cu foil substrate using a simple thermal oxidation method. The phase and morphology of the CuO NWs could be controlled by synthesis temperature. Variation in oxidation states enables CuO NWs to form Cu (III) species, which is crucial in catalysing the eletro-oxidation of glucose. The Cu-based metal/oxide composite electrode works as a non-enzymatic biosensor that adapts to the fast, dynamic change in glucose concentration, with a low saturation concentration (~0.7 mM) and a lower detection limit of 0.1 mM, making CuO NWs an excellent sensor towards impaired fasting glucose. The simplicity, cost-effectiveness and non-toxicity features of this study might make a way for potentially scalable application in glucose biosensing.
Collapse
Affiliation(s)
- Xun Cao
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| |
Collapse
|
14
|
Ao Y, Ao J, Zhao L, Hu L, Qu F, Guo B, Liu X. Hierarchical Structures Composed of Cu(OH) 2 Nanograss within Directional Microporous Cu for Glucose Sensing. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:13659-13667. [PMID: 36318699 DOI: 10.1021/acs.langmuir.2c01300] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Cu(OH)2 nanomaterials are widely investigated for non-enzymatic glucose sensors due to their low-cost and excellent performance. Cu(OH)2 nanomaterials usually grow on substrates to form sensor electrodes. Reported works mainly focus on structure adjusting of the Cu(OH)2 nanostructures, while the optimization of substrates is still lacking. In the present work, directional porous Cu (DPC) was applied as the substrate for the growth of Cu(OH)2 nanograss (NG), and hierarchical structures of Cu(OH)2@DPC were prepared by alkaline oxidation. The morphology and microstructure evolution of the prepared hierarchical structures was investigated, and the non-enzymatic glucose sensing performance was evaluated. Cu(OH)2@DPC exhibits enhanced comprehensive non-enzymatic glucose sensing performance compared to the reported ones, which may benefit from both the effective adsorption of the Cu(OH)2 NG with a relatively high surface area and the high solute exchange of the DPC by a channel effect. This work provides new insights into the further improvement of the non-enzymatic glucose sensing performance of Cu(OH)2 nanostructures by optimizing the substrate structure.
Collapse
Affiliation(s)
- Yibo Ao
- Institute of Materials, China Academy of Engineering Physics, Mianyang621908, China
- School of Materials Science and Engineering, Xihua University, Chengdu610039, China
- West China Hospital of Stomatology, Sichuan University, Chengdu610065, China
| | - Jinqing Ao
- School of Materials Science and Engineering, Xihua University, Chengdu610039, China
| | - Ling Zhao
- Institute of Materials, China Academy of Engineering Physics, Mianyang621908, China
| | - Liwei Hu
- Institute of Materials, China Academy of Engineering Physics, Mianyang621908, China
| | - Fengsheng Qu
- Institute of Materials, China Academy of Engineering Physics, Mianyang621908, China
| | - Biao Guo
- School of Materials Science and Engineering, Xihua University, Chengdu610039, China
| | - Xue Liu
- Institute of Materials, China Academy of Engineering Physics, Mianyang621908, China
| |
Collapse
|
15
|
Jang KB, Park KR, Mo CB, Kim S, Jeon J, Lim SC, Ahn C, Han H, Kim D, Lee SH, Kim KM, Mhin S. Synthetic control of the surface area in nickel cobalt oxide for glucose detection via additive-assisted wet chemical method. Sci Rep 2022; 12:19546. [PMID: 36379986 PMCID: PMC9666531 DOI: 10.1038/s41598-022-20859-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 09/20/2022] [Indexed: 11/16/2022] Open
Abstract
We investigated the effect of specific surface area on the electrochemical properties of NiCo2O4 (NCO) for glucose detection. NCO nanomaterials with controlled specific surface areas were prepared by additive-assisted hydrothermal synthesis, and self-assembled nanostructures with urchin-, pine-needle-, tremella-, and flower-like morphologies were obtained. The novelty of this method is the systematic control of chemical reaction routes assisted by the addition of different additives during synthesis, which results in the spontaneous formation of various morphologies without any difference in the crystal structure and chemical states of the constituent elements. Such morphological control of NCO nanomaterials leads to considerable changes in the electrochemical performance for glucose detection. Combined with materials characterization, the relationship between the specific surface area and the electrochemical performance is discussed for glucose detection. This work can provide scientific insights for tailoring the surface area of nanostructures, which determines their functionality for potential applications in glucose biosensors.
Collapse
Affiliation(s)
- Kyu-bong Jang
- grid.454135.20000 0000 9353 1134Korea Institute of Industrial Technology, 137-41 Gwahakdanji-ro, Gangneung, 25440 Republic of Korea
| | - Kyoung Ryeol Park
- grid.454135.20000 0000 9353 1134Korea Institute of Industrial Technology, 55, Jongga-ro, Jung-gu, Ulsan, 44413 Republic of Korea
| | - Chan Bin Mo
- grid.454135.20000 0000 9353 1134Korea Institute of Industrial Technology, 137-41 Gwahakdanji-ro, Gangneung, 25440 Republic of Korea
| | - Seongtak Kim
- grid.454135.20000 0000 9353 1134Korea Institute of Industrial Technology, 137-41 Gwahakdanji-ro, Gangneung, 25440 Republic of Korea
| | - Jaeeun Jeon
- grid.454135.20000 0000 9353 1134Korea Institute of Industrial Technology, 156 Gaetbeol-ro, Incheon, 21999 Republic of Korea
| | - Sung-chul Lim
- grid.454135.20000 0000 9353 1134Korea Institute of Industrial Technology, 156 Gaetbeol-ro, Incheon, 21999 Republic of Korea
| | - Chisung Ahn
- grid.454135.20000 0000 9353 1134Korea Institute of Industrial Technology, 156 Gaetbeol-ro, Incheon, 21999 Republic of Korea
| | - HyukSu Han
- grid.258676.80000 0004 0532 8339Department of Energy Engineering, Konkuk University, 120 Neungdong-ro, Seoul, 05029 Republic of Korea
| | - Dongju Kim
- grid.411203.50000 0001 0691 2332Department of Advanced Materials Engineering, Kyonggi University, 154-42 Gwanggyosan-ro, Suwon, 16227 Republic of Korea
| | - Seung Hwan Lee
- grid.49606.3d0000 0001 1364 9317School of Mechanical Engineering, Hanyang University, Seoul, 04763 Republic of Korea
| | - Kang Min Kim
- grid.454135.20000 0000 9353 1134Korea Institute of Industrial Technology, 137-41 Gwahakdanji-ro, Gangneung, 25440 Republic of Korea
| | - Sungwook Mhin
- grid.411203.50000 0001 0691 2332Department of Advanced Materials Engineering, Kyonggi University, 154-42 Gwanggyosan-ro, Suwon, 16227 Republic of Korea
| |
Collapse
|
16
|
Miyagi K, Takano T, Teramoto Y. Glucose‐sensitive structural color change of cholesteric liquid crystal formed by hydroxypropyl cellulose with phenylboronic acid moieties. J Appl Polym Sci 2022. [DOI: 10.1002/app.52984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Kazuma Miyagi
- Department of Forest Resource Chemistry, Forestry and Forest Products Research Institute Forest Research and Management Organization Ibaraki Japan
| | - Toshiyuki Takano
- Division of Forest and Biomaterials Science, Graduate School of Agriculture Kyoto University Kyoto Japan
| | - Yoshikuni Teramoto
- Division of Forest and Biomaterials Science, Graduate School of Agriculture Kyoto University Kyoto Japan
| |
Collapse
|
17
|
Preparation of three dimensional Cu2O/Au/GO hybrid electrodes and its application as a non-enzymatic glucose sensor. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107451] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
18
|
Figiela M, Wysokowski M, Stanisz E, Hao D, Ni BJ, Stepniak I. Highly sensitive, fast response and selective glucose detection based on CuO/nitrogen‐doped carbon non‐enzymatic sensor. ELECTROANAL 2022. [DOI: 10.1002/elan.202100475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
| | | | | | - Derek Hao
- University of Technology Sydney AUSTRALIA
| | | | | |
Collapse
|
19
|
Highly sensitive and selective non-enzymatic measurement of glucose using arraying of two separate sweat sensors at physiological pH. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
20
|
Falahi S, Jaafar A, Petrenko I, Zarejousheghani M, Ehrlich H, Rahimi P, Joseph Y. High-Performance Three-Dimensional Spongin-Atacamite Biocomposite for Electrochemical Nonenzymatic Glucose Sensing. ACS APPLIED BIO MATERIALS 2022; 5:873-880. [PMID: 35050590 DOI: 10.1021/acsabm.1c01248] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
The design of sensitive and cost-effective biocomposite materials with high catalytic activity for the effective electrooxidation of glucose plays a key role in developing enzyme-free glucose sensors. The porous three-dimensional (3D) spongin scaffold of marine sponge origin provides an excellent template for the growth of atacamite crystals and improves the activity of atacamite as a catalyst. By using the design of experiment method, the influence of different parameters on the electrode efficiency was optimized. The optimized sensor based on spongin-atacamite showed distinguished performance toward glucose with two linear ranges of 0.4-200 μM and 0.2-10 mM and high sensitivities of 3908.4 and 600.5 μA mM-1 cm-2, respectively. Importantly, the designed sensor exhibited strong selectivity and favorable stability, reproducibility, and repeatability. The performance in the real application was estimated by glucose detection in spiked human blood serum samples, which verified its great potential as a reliable platform for enzyme-free glucose sensing.
Collapse
Affiliation(s)
- Sedigheh Falahi
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Alaa Jaafar
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Iaroslav Petrenko
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Mashaalah Zarejousheghani
- Freiberg Water Research Center, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Hermann Ehrlich
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Parvaneh Rahimi
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany.,Freiberg Water Research Center, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| | - Yvonne Joseph
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany.,Freiberg Water Research Center, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany
| |
Collapse
|
21
|
Dendritic Cu(OH)2 nanostructures decorated pencil graphite electrode as a highly sensitive and selective impedimetric non-enzymatic glucose sensor in real human serum blood samples. MONATSHEFTE FUR CHEMIE 2022. [DOI: 10.1007/s00706-021-02883-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
22
|
Kang M, Bae M, Park S, Hong H, Yoo T, Kim Y, Jang M, Kim YS, Piao Y. Facile and scaleable transformation of Cu nanoparticles into high aspect ratio Cu oxide nanowires in methanol. RSC Adv 2022; 12:11526-11533. [PMID: 35425029 PMCID: PMC9006346 DOI: 10.1039/d2ra00510g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 04/07/2022] [Indexed: 12/05/2022] Open
Abstract
In this work, a facile synthetic route for the preparation of high aspect ratio Cu oxide nanowires is reported. The preparation of the Cu oxide nanowires begins with the generation of pure Cu nanoparticles by inert gas condensation (IGC) method, follows by dispersing the obtained nanoparticles in methanol with the aid of ultrasonication. The mixture is stored at different temperature for the transformation from Cu nanoparticle to Cu oxide nanowires. The influences of the kind of solution, the ratio of methanol to Cu nanoparticle, dispersion time and temperature towards the generation of Cu oxide nanowires are studied in detail. Scanning electron microscopy studies indicate that high aspect ratio Cu oxide nanowires with diameter of a few tens of nanometers and length up to several tens of micrometers could be obtained under proper conditions. The mechanism for the transformation of Cu nanoparticles to Cu oxide nanowires is also investigated. We proposed a facile synthetic route to Cu oxide nanowires with a high aspect ratio. The approach shown in this work is suitable for scale-up synthesis.![]()
Collapse
Affiliation(s)
- Minkyu Kang
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
| | - Minjun Bae
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
| | - Sumin Park
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
| | - Hwichan Hong
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
| | - Taehyun Yoo
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
| | - Yonghwan Kim
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
| | - Myeongseok Jang
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
| | - Young-Seok Kim
- Korea Electronics Technology Institute (KETI), 13509 Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Yuanzhe Piao
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
- Advanced Institutes of Convergence Technology, Seoul National University, 16229 Suwon-si, Gyeonggi-do, Republic of Korea
| |
Collapse
|
23
|
Lin WJ, Lin YS, Chang HT, Unnikrishnan B, Huang CC. Electrocatalytic CuBr@CuO nanoparticles based salivary glucose probes. Biosens Bioelectron 2021; 194:113610. [PMID: 34500227 DOI: 10.1016/j.bios.2021.113610] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 08/25/2021] [Accepted: 09/01/2021] [Indexed: 11/19/2022]
Abstract
Highly electrocatalytic cuprous halide/copper oxide nanoparticles (CuX@CunO NPs; X = Cl, Br or I; n = 1 or 2) have been fabricated on copper foils for sensitive detection of glucose. Formation of CuX@CunO NPs involves two steps- in situ electrochemical deposition of CuX on the foil and then conversion of CuX to CunO. The deposited CuX converts to CunO, leading to the generation of abundant oxygen vacancies in the CuO lattice, enhancing the number of catalytically active sites, and improving the charge transfer efficiency. Among the as-prepared electrodes, CuBr@CuO NP ones provide the highest electrocatalytic activity toward the oxidation of glucose. The electrode provides electrocatalytic activity toward the oxidation of glucose at a low overpotential of 0.25 V (vs. SCE), which is lower than that (0.40 V) of unmodified copper electrodes. The generated anodic current is proportional to glucose concentration in an alkaline medium, with a good linear range from 5.0 μM to 3.51 mM (R2 = 0.995). Its reliability has been validated by detecting the glucose concentration in saliva samples at different time intervals after a meal. The results are in good correlation with the blood glucose level determined by using a commercial blood glucose meter. Our CuBr@CuO NP electrode possesses great potential for monitoring salivary glucose to achieve the purpose of noninvasive glucose monitoring for patients with diabetes in the future.
Collapse
Affiliation(s)
- Wei-Jan Lin
- Department of Chemistry, National Taiwan University, Taipei, 10617, Taiwan
| | - Yu-Syuan Lin
- Department of Chemistry, National Taiwan University, Taipei, 10617, Taiwan
| | - Huan-Tsung Chang
- Department of Chemistry, National Taiwan University, Taipei, 10617, Taiwan.
| | - Binesh Unnikrishnan
- Department of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung, 20224, Taiwan
| | - Chih-Ching Huang
- Department of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung, 20224, Taiwan; Center of Excellence for the Oceans, National Taiwan Ocean University, Keelung, 20224, Taiwan; School of Pharmacy, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, 80708, Taiwan.
| |
Collapse
|
24
|
Nonenzymatic electrochemical sensors via Cu native oxides (CuNOx) for sweat glucose monitoring. SENSING AND BIO-SENSING RESEARCH 2021. [DOI: 10.1016/j.sbsr.2021.100453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
25
|
Advances on ultra-sensitive electrospun nanostructured electrochemical and colorimetric sensors for diabetes mellitus detection. NANO MATERIALS SCIENCE 2021. [DOI: 10.1016/j.nanoms.2021.05.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
26
|
Zhang G, Zeng H, Liu J, Nagashima K, Takahashi T, Hosomi T, Tanaka W, Yanagida T. Nanowire-based sensor electronics for chemical and biological applications. Analyst 2021; 146:6684-6725. [PMID: 34667998 DOI: 10.1039/d1an01096d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Detection and recognition of chemical and biological species via sensor electronics are important not only for various sensing applications but also for fundamental scientific understanding. In the past two decades, sensor devices using one-dimensional (1D) nanowires have emerged as promising and powerful platforms for electrical detection of chemical species and biologically relevant molecules due to their superior sensing performance, long-term stability, and ultra-low power consumption. This paper presents a comprehensive overview of the recent progress and achievements in 1D nanowire synthesis, working principles of nanowire-based sensors, and the applications of nanowire-based sensor electronics in chemical and biological analytes detection and recognition. In addition, some critical issues that hinder the practical applications of 1D nanowire-based sensor electronics, including device reproducibility and selectivity, stability, and power consumption, will be highlighted. Finally, challenges, perspectives, and opportunities for developing advanced and innovative nanowire-based sensor electronics in chemical and biological applications are featured.
Collapse
Affiliation(s)
- Guozhu Zhang
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan.
| | - Hao Zeng
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan.
| | - Jiangyang Liu
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan.
| | - Kazuki Nagashima
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan. .,JST-PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Tsunaki Takahashi
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan. .,JST-PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Takuro Hosomi
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan. .,JST-PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Wataru Tanaka
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan.
| | - Takeshi Yanagida
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8654, Japan. .,Institute for Materials Chemistry and Engineering, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka, 816-8580, Japan
| |
Collapse
|
27
|
Rajaji U, Ganesh PS, Chen SM, Govindasamy M, Kim SY, A. Alshgari R, Shimoga G. Deep eutectic solvents synthesis of perovskite type cerium aluminate embedded carbon nitride catalyst: High-sensitive amperometric platform for sensing of glucose in biological fluids. J IND ENG CHEM 2021. [DOI: 10.1016/j.jiec.2021.07.015] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
28
|
Manafi-Yeldaghermani R, Shahrokhian S, Hafezi Kahnamouei M. Facile preparation of a highly sensitive non-enzymatic glucose sensor based on the composite of Cu(OH)2 nanotubes arrays and conductive polypyrrole. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106636] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
29
|
Mishra AK, Jarwal DK, Mukherjee B, Jit S. CuO Nanoparticles Decorated ZnO Nanorods Based Extended-Gate Field-Effect-Transistor (EGFET) for Enzyme-Free Glucose Sensing Application. IEEE Trans Nanobioscience 2021; 21:3-9. [PMID: 34520359 DOI: 10.1109/tnb.2021.3112539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In this work, CuO nanoparticles (NPs) decorated zinc oxide nanorods (ZnO NRs) on fluorine-doped tin oxide (FTO) substrate has been used as a working electrode. This working electrode has been used as an extended gate for field-effect transistor. The main objective is to use the EGFET (extended gate field effect transistor) as a glucose sensor. The proposed glucose sensor has good sensitivity of 6.643 mV/mM with a wide range of linearity (1mM-8mM) which covers the glucose level of human blood ranging from 4.4 mM to 6.6 mM. This novel concept of the glucose sensing using CuO NPs decorated ZnO nanorods based EGFET may be explored for sensing other saccharides such as mannose, fructose, and sucrose. This vertically grown ZnO nanorods decorated with CuO NPs based electrode gives reliable selectivity, good repeatability, and more stability. The performance of proposed sensor is also compared with commercially available glucose sensors. The sensitivity performance of the glucose sensor also confirms the capability to detect the glucose level from human blood and serum.
Collapse
|
30
|
Developments of the Electroactive Materials for Non-Enzymatic Glucose Sensing and Their Mechanisms. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2020025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
A comprehensive review of the electroactive materials for non-enzymatic glucose sensing and sensing devices has been performed in this work. A general introduction for glucose sensing, a facile electrochemical technique for glucose detection, and explanations of fundamental mechanisms for the electro-oxidation of glucose via the electrochemical technique are conducted. The glucose sensing materials are classified into five major systems: (1) mono-metallic materials, (2) bi-metallic materials, (3) metallic-oxide compounds, (4) metallic-hydroxide materials, and (5) metal-metal derivatives. The performances of various systems within this decade have been compared and explained in terms of sensitivity, linear regime, the limit of detection (LOD), and detection potentials. Some promising materials and practicable methodologies for the further developments of glucose sensors have been proposed. Firstly, the atomic deposition of alloys is expected to enhance the selectivity, which is considered to be lacking in non-enzymatic glucose sensing. Secondly, by using the modification of the hydrophilicity of the metallic-oxides, a promoted current response from the electro-oxidation of glucose is expected. Lastly, by taking the advantage of the redistribution phenomenon of the oxide particles, the usage of the noble metals is foreseen to be reduced.
Collapse
|
31
|
Yuan K, Zhang Y, Huang S, Yang S, Zhao S, Liu F, Peng Q, Zhao Y, Zhang G, Fan J, Zang G. Copper Nanoflowers on Carbon Cloth as a Flexible Electrode Toward Both Enzymeless Electrocatalytic Glucose and H
2
O
2. ELECTROANAL 2021. [DOI: 10.1002/elan.202100029] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Kun Yuan
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Yuchan Zhang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shihao Huang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shengfei Yang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shuang Zhao
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
- Key Laboratory for Biorheological Science and Technology of Ministry of Education State and Local Joint Engineering Laboratory for Vascular Implants Bioengineering College of Chongqing University Chongqing 400030 China
| | - Fangxin Liu
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Qianyu Peng
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Yinping Zhao
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Guangyuan Zhang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Jingchuan Fan
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Guangchao Zang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| |
Collapse
|
32
|
Anand VK, Bhatt K, Kumar S, Archana B, Sharma S, Singh K, Gupta M, Goyal R, Virdi GS. Sensitive and Enzyme-Free Glucose Sensor Based on Copper Nanowires/Polyaniline/Reduced Graphene Oxide Nanocomposite Ink. INTERNATIONAL JOURNAL OF NANOSCIENCE 2021. [DOI: 10.1142/s0219581x21500204] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
In this paper, we report the preparation and characterization of a sensitive and reusable nonenzymatic glucose (NEG) sensor based on copper nanowires (CuNWs)/polyaniline (PANI)/reduced graphene oxide (rGO) nanocomposite ink. The CuNWs/PANI/rGO nanocomposite ink was prepared by solvothermal mixing of CuNWs, PANI, rGO and binders. The X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), Fourier Transform Infra-Red (FT-IR) spectroscopy techniques were used to assess the structural and morphological parameters of prepared nanocomposite ink. The cyclic voltammetry (CV) technique was used to estimate the electrochemical behavior of prepared NEG sensor. The structural, morphological and spectroscopy results confirmed the change in morphological and oxidation state of CuNWs to CuO nanostructures as a constituent of nanocomposite ink. The CuO nanostructures supported on PANI/rGO demonstrated good electrochemical stability and great electrocatalytic activity toward glucose oxidation. At a glucose oxidation potential of 0.64V, the prepared NEG sensor exhibited great electrocatalytic ability by offering a high sensitivity of 843.06[Formula: see text]AmM[Formula: see text]cm[Formula: see text] in the linear glucose range 0–4mM with a lower detection limit of 1.6mM. In addition to these outstanding performance characteristics, CuNWs/PANI/rGO nanocomposite ink-based NEG sensor has the advantages of ease of fabrication, low cost and reusability.
Collapse
Affiliation(s)
| | - Kapil Bhatt
- ECE Department, UIT, Himachal Pradesh University, Shimla, India
- UIET, Kurukshetra University, Kurukshetra, India
| | - Sandeep Kumar
- National Centre for Flexible Electronics, Indian Institute of Technology, Kanpur, India
| | - B. Archana
- ECE Department, Ambala College of Engineering and Applied Research, Ambala, India
| | | | | | - Monish Gupta
- UIET, Kurukshetra University, Kurukshetra, India
| | - Rakesh Goyal
- I. K. Gujral Punjab Technical University, Jalandhar, India
| | - G. S. Virdi
- I. K. Gujral Punjab Technical University, Jalandhar, India
| |
Collapse
|
33
|
Mandal D, Biswas S, Chowdhury A, De D, Tiwary CS, Gupta AN, Singh T, Chandra A. Hierarchical cage-frame type nanostructure of CeO 2 for bio sensing applications: from glucose to protein detection. NANOTECHNOLOGY 2021; 32:025504. [PMID: 32932238 DOI: 10.1088/1361-6528/abb8a8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Self-assembled hierarchical nanostructures are slowly superseding their conventional counterparts for use in biosensors. These morphologies show high surface area with tunable porosity and packing density. Modulating the interfacial interactions and subsequent particle assembly occurring at the water-and-oil interface in inverse miniemulsions, are amongst the best strategies to stabilize various type of hollow nanostructures. The paper presents a successful protocol to obtain CeO2 hollow structures based biosensors that are useful for glucose to protein sensing. The fabricated glucose sensor is able to deliver high sensitivity (0.495 μA cm-2 nM-1), low detection limit (6.46 nM) and wide linear range (0 nM to 600 nM). CeO2 based bioelectrode can also be considered as a suitable candidate for protein sensors. It can detect protein concentrations varying from 0 to 30 µM, which is similar or higher than most reports in the literature. The limit of detection (LOD) for protein was ∼0.04 µM. Therefore, the hollow CeO2 electrodes, with excellent reproducibility, stability and repeatability, open a new area of application for cage-frame type particles.
Collapse
Affiliation(s)
- Debabrata Mandal
- School of Nanoscience and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
- School of Energy Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Sudipta Biswas
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Ananya Chowdhury
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Debajyoti De
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Chandra Sekar Tiwary
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Amar Nath Gupta
- School of Nanoscience and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Trilok Singh
- School of Energy Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Amreesh Chandra
- School of Nanoscience and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
34
|
Muthukumar T, Arumugam E, Chandrasekaran S, Karuppiah C, Kodirajan S. Phytogenic synthesis of Co3O4 nanorods and its application in biomolecule sensing and antifungal activity. INORG CHEM COMMUN 2021. [DOI: 10.1016/j.inoche.2020.108305] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
35
|
Jadoon T, Mahmood T, Ayub K. Silver cluster (Ag 6) decorated coronene as non-enzymatic sensor for glucose and H 2O 2. J Mol Graph Model 2020; 103:107824. [PMID: 33360482 DOI: 10.1016/j.jmgm.2020.107824] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 12/04/2020] [Accepted: 12/08/2020] [Indexed: 01/09/2023]
Abstract
Silver-graphene quantum dots are promising electrochemical sensors due to their unique electronic properties. Herein, we report the comprehensive DFT study to explore the electronic properties of silver cluster (Ag6) decorated coronene as model for silver graphene quantum dots. The current study aims to investigate the sensing ability of silver-coronene complex for non-enzymatic electrochemical detection of glucose & H2O2. The stability of the complexes of analytes with silver decorated coronene is supported by their greater interaction energies (-36.7 to -44.9 kcal mol-1). NBO charge analysis and charge decomposition analysis (CDA) reveal donor-acceptor charge transfer interactions in the complexes. Frontier molecular orbital analysis illustrates that charge is transferred from analytes to silver decorated coronene during excitation from HOMO to LUMO. The Uv-visible results show that λmax is red shifted during interactions of analytes with silver decorated coronene. The NCI analysis illustrates the strong non-covalent (M … O) and unusual M … H-O interactions in the complexes. The precedent sensing performance of Ag6-coronene might be attributed to the synergistic effect of both silver clusters and coronene in the composite. The evaluated results validate the excellent sensing ability of silver-graphene quantum dots for the detection of glucose & H2O2. The outcome of the current study and its prospects will open the avenue for the rational development of smart sensors.
Collapse
Affiliation(s)
- Tabish Jadoon
- Department of Chemistry, COMSATS University Abbottabad Campus, 22060, Pakistan
| | - Tariq Mahmood
- Department of Chemistry, COMSATS University Abbottabad Campus, 22060, Pakistan
| | - Khurshid Ayub
- Department of Chemistry, COMSATS University Abbottabad Campus, 22060, Pakistan.
| |
Collapse
|
36
|
Functional nanostructured metal oxides and its hybrid electrodes – Recent advancements in electrochemical biosensing applications. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105522] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
37
|
Highly Sensitive Non-Enzymatic Detection of Glucose at MWCNT-CuBTC Composite Electrode. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10238419] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
A novel electrochemical glucose sensor was developed, based on a multiwall carbon nanotubes (MWCNTs)-copper-1,3,5-benzenetricarboxylic acid (CuBTC)-epoxy composite electrode, named MWCNT-CuBTC. The electrode nanocomposite was prepared by a two-roll mill procedure and characterized morphostructurally by scanning electron microscopy (SEM). The CuBTC formed defined crystals with a wide size distribution, which were well dispersed and embedded in the MWCNTs. Its electrical conductivity was determined by four-point probe contact (DC) conductivity measurements. The electroactive surface area, determined using cyclic voltammetry (CV), was found to be 6.9 times higher than the geometrical one. The results of the electrochemical measurements using CV, linear sweep voltammetry (LSV), differential pulse voltammetry (DPV), chronoamperometry (CA) and multiple pulse amperometry (MPA) showed that the MWCNT-CuBTC composite electrode displayed high electrocatalytic activity toward the oxidation of glucose and, as a consequence, very high sensitivity. The best sensitivity of 14,949 µAmM−1cm−1 was reached using MPA at the potential value of 0.6 V/SCE, which was much higher in comparison with other copper-based electrodes reported in the literature. The good analytical performance, low cost and simple preparation method make this novel electrode material promising for the development of an effective glucose sensor.
Collapse
|
38
|
3D shell-core structured NiCu-OH@Cu(OH)2 nanorod: A high-performance catalytic electrode for non-enzymatic glucose detection. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114477] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
39
|
Wang Q, Wang Z, Dong Q, Yu R, Zhu H, Zou Z, Yu H, Huang K, Jiang X, Xiong X. NiCl(OH) nanosheet array as a high sensitivity electrochemical sensor for detecting glucose in human serum and saliva. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105184] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
40
|
Arabali V, Malekmohammadi S, Karimi F. Surface amplification of pencil graphite electrode using CuO nanoparticle/polypyrrole nanocomposite; a powerful electrochemical strategy for determination of tramadol. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105179] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
41
|
Effect of tungsten doping on the structural, morphological and bactericidal properties of nanostructured CuO. PLoS One 2020; 15:e0239868. [PMID: 32986775 PMCID: PMC7521724 DOI: 10.1371/journal.pone.0239868] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 09/15/2020] [Indexed: 11/19/2022] Open
Abstract
Copper oxide (CuO) has been broadly used in different technological and biological applications. However, based on the literature review, there are few reports describing the synthesis of tungsten doped copper oxide and its biological applications, although CuO and W (tungsten) based nanomaterials have been reportedly already synthesized. In this study we synthesized novel CuO and CuO/W (at.1%, 2% and 4%) nanoparticles and explored their tungsten content-dependent bactericide activity. In order to obtain the materials, was used a co-precipitation method which is of low cost. The synthesized materials were characterized by x-ray diffraction (XRD); XRD results indicated that only the sample with at.1% of W presented pure Tenorite phase. Diffuse reflectance spectroscopy (DRS) allowed to obtain the band gap energy values; CuO/W (at.2%) sample exhibited the minimum value of 2.62 eV. Grains sizes ranging from 39.78 to 53.47 nm were established through field emission—scanning electronic microscopy (FE-SEM), and these sizes were confirmed by transmission electron microscopy (TEM). Doping with W also influenced the morphology obtained in all cases. BET (Brunauer, Emmett, Teller) analysis allowed to establish an increase in specific surface area and pore size with W doping. The particle size was determined by dynamic light scattering (DLS). The bactericidal properties were tested using well diffusion method for Escherichia coli and Staphylococcus aureus bacteria. Bactericide response of CuO nanoparticles was improved by the inclusion of W dopant into the CuO structure, leading to an expansion in the inhibition zone for the CuO/W (at.1%) sample; inhibition halo diameters were 1.5 and 12 mm for CuO and CuO/W (at.1%), respectively. Hence, it was possible to infer the remarkable importance of the crystalline phase, morphology, particle size and specific superficial area of the CuO/W (at.1%) nanoparticles in its bactericide performance. WO3 secondary phase affected the bactericide response of the materials obtained at at.2% and at.4% of tungsten content.
Collapse
|
42
|
Chandrasekaran N, Matheswaran M. Unique Nonenzymatic Glucose Sensor Using a Hollow-Shelled Triple Oxide Mn-Cu-Al Nanocomposite. ACS OMEGA 2020; 5:23502-23509. [PMID: 32984668 PMCID: PMC7512457 DOI: 10.1021/acsomega.0c00417] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 04/14/2020] [Indexed: 06/11/2023]
Abstract
Glucose monitoring devices for diabetes mellitus, which is a worldwide significant health issue, have attracted attention of many researchers. Herein, we report a hollow Mn-Cu-Al oxide nanocomposite (HMCA) by a microwave-assisted technique showing excellent sensing abilities toward glucose. Also, it possesses a superb supercapacitor activity described in our previous paper. The sensitivity value of the nanocomposite is 2.194 mA mM-1 cm-2 with a low detection limit of 0.43 μM (S/N = 3). The high sensitivity and low detection limit were the results of the large surface area of the nanocomposite and the redox nature of CuO and MnO2. It shows a selective detection of glucose levels in blood serum. The hollow nanocomposite has been useful for monitoring the glucose level in blood serum and holds great potential for diabetes mellitus and clinical diagnosis.
Collapse
Affiliation(s)
| | - Manickam Matheswaran
- Department
of Chemical Engineering, National Institute
of Technology Tiruchirappalli, Tiruchirappalli 620015, India
| |
Collapse
|
43
|
Sun S, Shi N, Zhang B, Liao X, Huang Z, Chen X, Pu X, Yin G. Hierarchically porous CuO spindle-like nanosheets grown on a carbon cloth for sensitive non-enzymatic glucose sensoring. NANOTECHNOLOGY 2020; 31:375502. [PMID: 32460258 DOI: 10.1088/1361-6528/ab96e2] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Herein, porous CuO spindle-like nanosheets were fabricated on a carbon cloth using a facile hydrothermal method, and surface morphology, microstructure, and glucose sensing performance were studied. The porous spindle-like nanosheets are constructed by nanoparticles and slit-like pores, exhibiting a hierarchical structure. When used for non-enzymatic glucose sensoring, the obtained CuO nanosheet electrode exhibits a wide linear range from 0.05 to 3.30 mM, a high sensitivity of 785.2 μA mM-1 cm-2 and a low detection limit of 0.22 μM (S/N = 3). Besides, good selectivity, stability, and reproducibility for glucose detection indicate a promising application of CuO nanosheet electrodes as non-enzymatic glucose sensors.
Collapse
Affiliation(s)
- Shupei Sun
- College of Materials Science and Engineering, Sichuan University, Chengdu, Sichuan 610065, People's Republic of China
| | | | | | | | | | | | | | | |
Collapse
|
44
|
Azargoshasb T, Navid HA, Parvizi R, Heidari H. Evanescent Wave Optical Trapping and Sensing on Polymer Optical Fibers for Ultra-Trace Detection of Glucose. ACS OMEGA 2020; 5:22046-22056. [PMID: 32923763 PMCID: PMC7482082 DOI: 10.1021/acsomega.0c01908] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Accepted: 08/07/2020] [Indexed: 06/01/2023]
Abstract
Graphene sensitization of glucose-imprinted polymer (G-IP)-coated optical fiber has been introduced as a new biosensor for evanescent wave trapping on the polymer optical fiber to detect low-level glucose. The developed sensor operates based on the evanescent wave modulation principle. Full characterization via atomic force microscopy (AFM), Fourier transform infrared (FTIR) spectroscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM), Raman spectroscopy, high-resolution transmission electron microscopy (HRTEM), and N2 adsorption/desorption of as-prepared G-IP-coated optical fibers was experimentally tested. Accordingly, related operational parameters such as roughness and diameter were optimized. Incorporating graphene into the G-IP not only steadily promotes the electron transport between the fiber surface and as-proposed G-IP but also significantly enhances the sensitivity by acting as a carrier for immobilizing G-IP with specific imprinted cavities. The sensor demonstrates a fast response time (5 s) and high sensitivity, selectivity, and stability, which cause a wide linear range (10-100 nM) and a low limit of detection (LOD = 2.54 nM). Experimental results indicate that the developed sensor facilitates online monitoring and remote sensing of glucose in biological liquids and food samples.
Collapse
Affiliation(s)
- Tahereh Azargoshasb
- Department
of Laser and Optical Engineering, University
of Bonab, Bonab 5551761167, Iran
| | - H. Ali Navid
- Department
of Laser and Optical Engineering, University
of Bonab, Bonab 5551761167, Iran
| | - Roghaieh Parvizi
- Department
of Physics, College of Sciences, Yasouj
University, Yasouj 75914-353, Iran
| | - Hadi Heidari
- School
of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom
| |
Collapse
|
45
|
Viswanathan P, Wang K, Li J, Hong JD. Multicore–Shell Ag–CuO networked with CuO nanorods for enhanced non-enzymatic glucose detection. Colloids Surf A Physicochem Eng Asp 2020. [DOI: 10.1016/j.colsurfa.2020.124816] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
46
|
Lynch PJ, Amorim Graf A, Ogilvie SP, Large MJ, Salvage JP, Dalton AB. Surfactant-free liquid-exfoliated copper hydroxide nanocuboids for non-enzymatic electrochemical glucose detection. J Mater Chem B 2020; 8:7733-7739. [PMID: 32725027 DOI: 10.1039/d0tb01476a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
To facilitate printable sensing solutions particles need to be suspended and stabilised in a liquid medium. Hansen parameters were used to identify that alcohol-water blends are ideal for stabilising colloidal copper hydroxide in dispersion. The suspended material can be further separated in various size fractions with a distinct cuboid geometry which was verified using atomic force microscopy. This facilitates the development of Raman spectroscopic metrics for determining particle sizes. This aspect ratio is related to the anisotropic crystal structure of the bulk crystallites. As the size of the nanocuboids decreases electrochemical sensitivity of the material increases due to an increase in specific surface area. Electrochemical glucose sensitivity was investigated using both cyclic voltammetry and chronoamperometry. The sensitivity is noted to saturate with film thickness. The electrochemical response of 253 mA M-1 cm-2 up to 0.1 mM and 120 mA cm-2 up to 0.6 mM allow for calibration of potential devices. These results indicate suitability for use as a glucose sensor and, due to the surfactant-free, low boiling point solvent approach used to exfoliate the nanocuboids, it is an ideal candidate for printable solutions. The ease of processing will also allow this material to be integrated in composite films for improved functionality in future devices.
Collapse
Affiliation(s)
- Peter J Lynch
- University of Sussex, Department of Physics and Astronomy, Brighton, BN1 9RH, UK.
| | | | | | | | | | | |
Collapse
|
47
|
Mishra AK, Jarwal DK, Mukherjee B, Kumar A, Ratan S, Tripathy MR, Jit S. Au nanoparticles modified CuO nanowireelectrode based non-enzymatic glucose detection with improved linearity. Sci Rep 2020; 10:11451. [PMID: 32651423 PMCID: PMC7351779 DOI: 10.1038/s41598-020-67986-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 06/01/2020] [Indexed: 11/18/2022] Open
Abstract
This paper explores gold nanoparticle (GNP) modified copper oxide nanowires(CuO NWs)based electrode grown on copper foil for non-enzymatic glucose detection in a wide linear ranging up to 31.06 mM, and 44.36 mM at 0.5 M NaOH and 1 M NaOH concentrations. The proposed electrode can be used to detect a very low glucose concentration of 0.3 µM with a high linearity range of 44.36mM and sensitivity of 1591.44 µA mM-1 cm-2. The electrode is fabricated by first synthesizing Cu (OH)2 NWs on a copper foil by chemical etching method and then heat treatment is performed to convert Cu (OH)2 NWs into CuO NWs. The GNPs are deposited on CuO NWs to enhance the effective surface-to-volume ratio of the electrode with improved catalytic activity. The surface morphology has been investigated by XRD, XPS, FE-SEM and HR-TEM analysis. The proposed sensor is expected to detect low-level of glucose in urine, and saliva. At the same time, it can also be used to measure extremely high sugar levels (i.e. hyperglycemia) of ~ 806.5454 mg/dl. The proposed sensor is also capable of detecting glucose after multiple bending of the GNP modified CuO NWs electrode. The proposed device is also used to detect the blood sugar level in human being and it is found that this sensor's result is highly accurate and reliable.
Collapse
Affiliation(s)
- Ashwini Kumar Mishra
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Deepak Kumar Jarwal
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Bratindranath Mukherjee
- Department of Metallurgical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, India
| | - Amit Kumar
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Smrity Ratan
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Manas Ranjan Tripathy
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Satyabrata Jit
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India.
| |
Collapse
|
48
|
Li Q, Sun Q, Li Y, Wu T, Li S, Zhang H, Huang F. Solar-Heating Crassula perforata-Structured Superoleophilic CuO@CuS/PDMS Nanowire Arrays on Copper Foam for Fast Remediation of Viscous Crude Oil Spill. ACS APPLIED MATERIALS & INTERFACES 2020; 12:19476-19482. [PMID: 32267143 DOI: 10.1021/acsami.0c01207] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In nature, leaf photosynthesis is the most common solar energy conversion system, which involves light absorption and conversion processes. Most interestingly, the leaves of a green plant are almost lamellar. Herein, inspired by the structure and light conversion capacity of plants, we developed a Crassula perforata-structured CuO@CuS/poly(dimethylsiloxane) (CuO@CuS/PDMS) nanowire arrays (NWAs) on copper foam (CF) with effective light-to-heat conversion to clean up viscous crude oil (∼105 mPa s) by in situ reducing the viscosity of crude oil. The C. perforata-structured CuO@CuS/PDMS core/shell NWAs were grown on copper foam with high density and uniformity, exhibiting excellent light adsorption and photothermal conversion efficiency. When simulated sunlight was irradiated on the structure of the CuO@CuS/PDMS NWAs/CF, abundant heat was generated and in situ reduced the viscosity of crude oil, which prominently increased the oil diffusion coefficient and sped up the oil sorption rate. The oil recovery procedure can realize a continuous clean up with the assistance of a pump device, and the crude oil adsorption capacity can reach up to 15.57 × 105 g/m3 during a 5 min adsorption process. The high-performance photothermal self-heated superoleophilic CuO@CuS/PDMS NWAs/CF has a promise of promoting the practical applications of the sorbents in the clean up of viscous crude oil spills.
Collapse
Affiliation(s)
- Qianqian Li
- Lab of Clean Energy & Environmental Catalysis, AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, P. R. China
| | - Qingyun Sun
- Lab of Clean Energy & Environmental Catalysis, AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, P. R. China
| | - Yinghui Li
- Lab of Clean Energy & Environmental Catalysis, AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, P. R. China
| | - Tao Wu
- Lab of Clean Energy & Environmental Catalysis, AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, P. R. China
| | - Shikuo Li
- Lab of Clean Energy & Environmental Catalysis, AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, P. R. China
| | - Hui Zhang
- Lab of Clean Energy & Environmental Catalysis, AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, P. R. China
| | - Fangzhi Huang
- Lab of Clean Energy & Environmental Catalysis, AnHui Province Key Laboratory of Chemistry for Inorganic/Organic Hybrid Functionalized Materials, School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601, P. R. China
| |
Collapse
|
49
|
WU L, LU ZW, MA Y, ZHANG JJ, MO GQ, DU HJ, YE JS. Cu(II) Metal-Organic Framework Encapsulated in Carbon Paste Electrode for High-Performance Non-Enzymatic Glucose Sensing. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1016/s1872-2040(20)60006-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
50
|
Zhou Z, Zhu Z, Cui F, Shao J, Zhou HS. CuO/Cu composite nanospheres on a TiO2 nanotube array for amperometric sensing of glucose. Mikrochim Acta 2020; 187:123. [DOI: 10.1007/s00604-019-4099-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Accepted: 12/26/2019] [Indexed: 01/31/2023]
|