Jing B, Lindsey BD. Very Low Frequency Radial Modulation for Deep Penetration Contrast-Enhanced Ultrasound Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:530-545. [PMID: 34972572 DOI: 10.1016/j.ultrasmedbio.2021.11.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 11/16/2021] [Accepted: 11/21/2021] [Indexed: 06/14/2023]
Abstract
Contrast-enhanced ultrasound imaging allows vascular imaging in a variety of diseases. Radial modulation imaging is a contrast agent-specific imaging approach for improving microbubble detection at high imaging frequencies (≥7.5 MHz), with imaging depth limited to a few centimeters. To provide high-sensitivity contrast-enhanced ultrasound imaging at high penetration depths, a new radial modulation imaging strategy using a very low frequency (100 kHz) ultrasound modulation wave in combination with imaging pulses ≤5 MHz is proposed. Microbubbles driven at 100 kHz were imaged in 10 successive oscillation states by manipulating the pulse repetition frequency to unlock the frame rate from the number of oscillation states. Tissue background was suppressed using frequency domain radial modulation imaging (F-RMI) and singular value decomposition-based radial modulation imaging (S-RMI). One hundred-kilohertz modulation resulted in significantly higher microbubble signal magnitude (63-88 dB) at the modulation frequency relative to that without 100-kHz modulation (51-59 dB). F-RMI produced images with high contrast-to-tissue ratios (CTRs) of 15 to 22 dB in a stationary tissue phantom, while S-RMI further improved the CTR (19-26 dB). These CTR values were significantly higher than that of amplitude modulation pulse inversion images (11.9 dB). In the presence of tissue motion (1 and 10 mm/s), S-RMI produced high-contrast images with CTR up to 18 dB; however, F-RMI resulted in minimal contrast enhancement in the presence of tissue motion. Finally, in transcranial ultrasound imaging studies through a highly attenuating ex vivo cranial bone, CTR values with S-RMI were as high as 23 dB. The proposed technique demonstrates successful modulation of microbubble response at 100 kHz for the first time. The presented S-RMI low-frequency radial modulation imaging strategy represents the first demonstration of real-time (20 frames/s), high-penetration-depth radial modulation imaging for contrast-enhanced ultrasound imaging.
Collapse
Affiliation(s)
- Bowen Jing
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA
| | - Brooks D Lindsey
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA; School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| |
Collapse
|
52
|
Keller SB, Lai TY, De Koninck L, Averkiou MA. Investigation of the Phase of Nonlinear Echoes From Microbubbles During Amplitude Modulation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1032-1040. [PMID: 35073259 DOI: 10.1109/tuffc.2022.3143810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Contrast-enhanced ultrasound (CEUS) imaging relies on distinguishing between microbubble and tissue echoes. Amplitude modulation (AM), a nonlinear pulsing scheme, has been developed to take advantage of the amplitude-dependent nonlinearity of microbubble echoes. However, with AM, tissue nonlinear propagation can also degrade the image contrast. Segmentation of CEUS images based on amplitude-dependent phase difference in the echoes, defined in this article as [Formula: see text], has been proposed as an additional method of enhancing contrast-to-tissue ratio as tissue is not expected to create the same degree of [Formula: see text]; however, this has not been robustly investigated. In this work, we evaluate the source of [Formula: see text] through simulations of unshelled versus shelled microbubble oscillation and simulations of nonlinear propagation in tissue. We then validate the simulated [Formula: see text] results with experimental [Formula: see text] measurements during in vitro scattering and imaging in a flow phantom. We show that shelled and unshelled microbubbles resulted in a [Formula: see text] with similar overall magnitude with some differences in trends, and that tissue echoes have a small yet detectable degree of [Formula: see text] due to nonlinear propagation. The results from this work can help inform optimal parameter selection for phase segmentation and implementation on a clinical scanner.
Collapse
|
53
|
Kratzer W, Güthle M, Dobler F, Seufferlein T, Graeter T, Schmidberger J, Barth TFE, Klaus J. Comparison of superb microvascular imaging (SMI) quantified with ImageJ to quantified contrast-enhanced ultrasound (qCEUS) in liver metastases-a pilot study. Quant Imaging Med Surg 2022; 12:1762-1774. [PMID: 35284256 PMCID: PMC8899953 DOI: 10.21037/qims-21-383] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 10/12/2021] [Indexed: 07/28/2023]
Abstract
BACKGROUND The aim of the study was to compare methods for the assessment of vascularisation of liver metastases (LM) between superb microvascular imaging (SMI), contrast-enhanced ultrasound, and microvascular density (MVD). METHODS SMI results were quantified as the vascularisation quotient (VQ), based on a grey-scale analysis with ImageJ image software. Those results were compared to contrast-enhanced ultrasonography (CEUS) values, calculated with VueBox®. MVD was measured with an anti-CD34 antibody. RESULTS This study included 13 patients with LM. The VQ showed a strong correlation with the quantified parameters of contrast-enhanced ultrasound. The parameters of quantified contrast-enhanced ultrasound compared with quantified SMI showed the following statistical correlations: peak enhancement (PE), in arbitrary unit (a.u.) (r=0.72104, P=0.0054), PE in Decibel (dB) (r=0.65918, P=0.00141), Wash-in- Area Under the Curve (WiAUC) in a.u. (r=0.63604, P=0.00194), Wash-in Perfusion-Index (WiPI) in a.u. (r=0.73337, P=0.0043), Wash-in Perfusion-Index (WiPI) in dB (r=0.65642, P=0.0194), Wash-in-Rate (WiR) in a.u. (r=0.7304, P=0.0036) and Wash-in-Rate (WiR) in dB (r=0.82897, P=0.0005). CONCLUSIONS Comparison of the two methods, SMI and contrast-enhanced ultrasound (CEUS), for quantitative assessment of vascularisation of LM showed good correlation. The contrast-independent Doppler technique SMI can qualitatively assess the vascularisation of LM.
Collapse
Affiliation(s)
- Wolfgang Kratzer
- Department of Internal Medicine I, University Hospital Ulm, Ulm, Germany
| | - Melanie Güthle
- Department of Internal Medicine I, University Hospital Ulm, Ulm, Germany
| | - Felix Dobler
- Department of Internal Medicine I, University Hospital Ulm, Ulm, Germany
| | - Thomas Seufferlein
- Department of Internal Medicine I, University Hospital Ulm, Ulm, Germany
| | - Tilmann Graeter
- Department of Diagnostic and Interventional Radiology, University Hospital Ulm, Ulm, Germany
| | | | - Thomas FE Barth
- Institute of Pathology, University Hospital Ulm, Ulm, Germany
| | - Jochen Klaus
- Department of Internal Medicine I, University Hospital Ulm, Ulm, Germany
| |
Collapse
|
54
|
Rousou C, de Maar J, Qiu B, van der Wurff-Jacobs K, Ruponen M, Urtti A, Oliveira S, Moonen C, Storm G, Mastrobattista E, Deckers R. The Effect of Microbubble-Assisted Ultrasound on Molecular Permeability across Cell Barriers. Pharmaceutics 2022; 14:494. [PMID: 35335871 PMCID: PMC8949944 DOI: 10.3390/pharmaceutics14030494] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 02/16/2022] [Accepted: 02/22/2022] [Indexed: 02/06/2023] Open
Abstract
The combination of ultrasound and microbubbles (USMB) has been applied to enhance drug permeability across tissue barriers. Most studies focused on only one physicochemical aspect (i.e., molecular weight of the delivered molecule). Using an in vitro epithelial (MDCK II) cell barrier, we examined the effects of USMB on the permeability of five molecules varying in molecular weight (182 Da to 20 kDa) and hydrophilicity (LogD at pH 7.4 from 1.5 to highly hydrophilic). Treatment of cells with USMB at increasing ultrasound pressures did not have a significant effect on the permeability of small molecules (molecular weight 259 to 376 Da), despite their differences in hydrophilicity (LogD at pH 7.4 from -3.2 to 1.5). The largest molecules (molecular weight 4 and 20 kDa) showed the highest increase in the epithelial permeability (3-7-fold). Simultaneously, USMB enhanced intracellular accumulation of the same molecules. In the case of the clinically relevant anti- C-X-C Chemokine Receptor Type 4 (CXCR4) nanobody (molecular weight 15 kDa), USMB enhanced paracellular permeability by two-fold and increased binding to retinoblastoma cells by five-fold. Consequently, USMB is a potential tool to improve the efficacy and safety of the delivery of drugs to organs protected by tissue barriers, such as the eye and the brain.
Collapse
Affiliation(s)
- Charis Rousou
- Department of Pharmaceutical Sciences, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.R.); (B.Q.); (K.v.d.W.-J.); (S.O.); (G.S.)
- Imaging and Oncology Division, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands; (J.d.M.); (C.M.); (R.D.)
| | - Josanne de Maar
- Imaging and Oncology Division, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands; (J.d.M.); (C.M.); (R.D.)
| | - Boning Qiu
- Department of Pharmaceutical Sciences, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.R.); (B.Q.); (K.v.d.W.-J.); (S.O.); (G.S.)
| | - Kim van der Wurff-Jacobs
- Department of Pharmaceutical Sciences, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.R.); (B.Q.); (K.v.d.W.-J.); (S.O.); (G.S.)
| | - Marika Ruponen
- School of Pharmacy, Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1 C, 70210 Kuopio, Finland; (M.R.); (A.U.)
| | - Arto Urtti
- School of Pharmacy, Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1 C, 70210 Kuopio, Finland; (M.R.); (A.U.)
- Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, Yliopistonkatu 4, 00100 Helsinki, Finland
- Institute of Chemistry, Saint Petersburg State University, Lieutenant Schmidt emb., 11/2, 199034 Saint Petersburg, Russia
| | - Sabrina Oliveira
- Department of Pharmaceutical Sciences, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.R.); (B.Q.); (K.v.d.W.-J.); (S.O.); (G.S.)
- Cell Biology, Neurobiology and Biophysics, Department of Biology, Faculty of Science, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands
| | - Chrit Moonen
- Imaging and Oncology Division, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands; (J.d.M.); (C.M.); (R.D.)
| | - Gert Storm
- Department of Pharmaceutical Sciences, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.R.); (B.Q.); (K.v.d.W.-J.); (S.O.); (G.S.)
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, 21 Lower Kent Ridge Rd, Singapore 119077, Singapore
- Department of Biomaterials Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands
| | - Enrico Mastrobattista
- Department of Pharmaceutical Sciences, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.R.); (B.Q.); (K.v.d.W.-J.); (S.O.); (G.S.)
| | - Roel Deckers
- Imaging and Oncology Division, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands; (J.d.M.); (C.M.); (R.D.)
| |
Collapse
|
55
|
Choi BE, Lee HS, Sung JH, Jeong EY, Park CY, Jeong JS. Polarization Inverted Ultrasound Transducer Based on Composite Structure for Tissue Harmonic and Frequency Compound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:273-282. [PMID: 34464259 DOI: 10.1109/tuffc.2021.3109458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Ultrasound transducer with polarization inversion technique (PIT) can provide dual-frequency feature for tissue harmonic imaging (THI) and frequency compound imaging (FCI). However, in the conventional PIT, the ultrasound intensity is reduced due to the multiple resonance characteristics of the combined piezoelectric element, and it is challenging to handle the thin piezoelectric layer required to make a PIT-based acoustic stack. In this study, an improved PIT using a piezo-composite layer was proposed to compensate for those problems simultaneously. The novel PIT-based acoustic stack also consists of two piezoelectric layers with opposite poling directions, in which the piezo-composite layer is located on the front side and the bulk-type piezoelectric layer is located on the back side. The thickness ratio between two piezoelectric layers is 0.5:0.5, but unlike a typical PIT model, it can generate dual-frequency spectrum. A finite element analysis (FEA) simulation was conducted, and subsequently, the prototype transducer was fabricated for performance demonstration. In the simulation and experiment, the intensity was increased by 56.76% and 30.88% compared to the conventional PIT model with the thickness ratio of 0.3:0.7. Thus, the proposed PIT-based transducer is expected to be useful in implementation of THI and FCI.
Collapse
|
56
|
McCall JR, Dayton PA, Pinton GF. Characterization of the Ultrasound Localization Microscopy Resolution Limit in the Presence of Image Degradation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:124-134. [PMID: 34524957 DOI: 10.1109/tuffc.2021.3112074] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Ultrasound localization microscopy (ULM) has been able to overcome the diffraction limit of ultrasound imaging. The resolution limit of ULM has been previously modeled using the Cramér-Rao lower bound (CRLB). While this model has been validated in a homogeneous medium, it estimates a resolution limit, which has not yet been achieved in vivo. In this work, we investigated the effects of three sources of image degradation on the resolution limit of ULM. The Fullwave simulation tool was used to simulate acquisitions of transabdominal contrast-enhanced data at depth. The effects of reverberation clutter, trailing clutter, and phase aberration were studied. The resolution limit, in the presence of reverberation clutter alone, was empirically measured to be up to 39 times worse in the axial dimension and up to 2.1 times worse in the lateral dimension than the limit predicted by the CRLB. While reverberation clutter had an isotropic impact on the resolution, trailing clutter had a constant impact on both dimensions across all signal-to-trailing-clutter ratios (STCR). Phase aberration had a significant impact on the resolution limit over the studied analysis ranges. Phase aberration alone degraded the resolution limit up to 70 and 160 [Formula: see text] in the lateral and axial dimensions, respectively. These results illustrate the importance of phase aberration correction and clutter filtering in ULM postprocessing. The analysis results were demonstrated through the simulation of the ULM process applied to a cross-tube model that was degraded by each of the three aforementioned sources of degradation.
Collapse
|
57
|
Hwang M, Back SJ, Didier RA, Lorenz N, Morgan TA, Poznick L, Steffgen L, Sridharan A. Pediatric contrast-enhanced ultrasound: optimization of techniques and dosing. Pediatr Radiol 2021; 51:2147-2160. [PMID: 32955599 DOI: 10.1007/s00247-020-04812-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/08/2020] [Accepted: 08/10/2020] [Indexed: 12/11/2022]
Abstract
When performing contrast-enhanced ultrasound (CEUS), ultrasound (US) scanner settings, examination technique, and contrast agent dose and administration must be optimized to ensure that high-quality, diagnostic and reproducible images are acquired for qualitative and quantitative interpretations. When carrying out CEUS in children, examination settings should be tailored to their body size and specific indications, similar to B-mode US. This review article details the basic background knowledge that is needed to perform CEUS optimally in children, including considerations related to US scanner settings and US contrast agent dose selection and administration techniques.
Collapse
Affiliation(s)
- Misun Hwang
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA. .,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
| | - Susan J Back
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Ryne A Didier
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Norbert Lorenz
- Children's Hospital, Dresden Municipal Hospital, Teaching-Hospital of Technical University, Dresden, Germany
| | - Trudy A Morgan
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| | - Laura Poznick
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| | - Ludwig Steffgen
- Trainings-Zentrum Ultraschall-Diagnostik LS GmbH, Mainleus, Germany
| | - Anush Sridharan
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| |
Collapse
|
58
|
Brown KG, Hoyt K. Evaluation of Nonlinear Contrast Pulse Sequencing for Use in Super-Resolution Ultrasound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:3347-3361. [PMID: 34181537 PMCID: PMC8588781 DOI: 10.1109/tuffc.2021.3092172] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The use of super-resolution ultrasound (SR-US) imaging greatly improves visualization of microvascular structures, but clinical adoption is limited by long imaging times. This method depends on detecting and localizing isolated microbubbles (MBs), forcing the use of a dilute contrast agent concentration. Contrast-enhanced ultrasound (CEUS) image acquisition times as long as minutes arise as the localization of thousands of MBs are acquired to form a complete SR-US image. In this article, we explore the use of nonlinear CEUS strategies using nonlinear fundamental contrast pulse sequencing (CPS) to increase the contrast-to-tissue ratio (CTR) and compare MB detection effectiveness to linear B-mode CEUS imaging. The CPS compositions of amplitude modulation (AM), pulse inversion (PI), and a combination of the two (AMPI) were studied. A simulation study combined the Rayleigh-Plesset-Marmottant (RPM) model of MB characteristics and a nonlinear tissue model using the k-Wave toolbox for MATLAB (MathWorks Inc., Natick, MA, USA). Validation was conducted using an in vitro flow phantom and in vivo in the rat hind-limb. Imaging was performed with a programmable US scanner (Vantage 256, Verasonics Inc., Kirkland, WA, USA) and customized to transmit a set of basis US pulses from which both B-mode US (frame rate (FR) of 800 Hz) and multiple nonlinear CPS compositions (FR of 200 Hz) could be assessed from identical in vitro and in vivo datasets using a near simultaneous method. The simulations suggest that MB characteristics, such as diameter and motion, help to predict which US imaging strategy will enhance MB detection. The in vitro and in vivo US imaging studies revealed that different subpopulations of polydisperse MB contrast agents were detected by linear imaging and by each different nonlinear CPS composition. The most effective single imaging strategy at a 200-Hz FR was found to be B-mode US imaging. However, a combination of B-mode US imaging with a nonlinear CPS imaging strategy was more effective in detecting MBs in vivo at all depths and was shown to shorten image acquisition time by an average of 33.3%-76.7% when combining one or more CPS sequences.
Collapse
|
59
|
Brown KG, Waggener SC, Redfern AD, Hoyt K. Faster super-resolution ultrasound imaging with a deep learning model for tissue decluttering and contrast agent localization. Biomed Phys Eng Express 2021; 7:10.1088/2057-1976/ac2f71. [PMID: 34644679 PMCID: PMC8594285 DOI: 10.1088/2057-1976/ac2f71] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Accepted: 10/13/2021] [Indexed: 11/12/2022]
Abstract
Super-resolution ultrasound (SR-US) imaging allows visualization of microvascular structures as small as tens of micrometers in diameter. However, use in the clinical setting has been impeded in part by ultrasound (US) acquisition times exceeding a breath-hold and by the need for extensive offline computation. Deep learning techniques have been shown to be effective in modeling the two more computationally intensive steps of microbubble (MB) contrast agent detection and localization. Performance gains by deep networks over conventional methods are more than two orders of magnitude and in addition the networks can localize overlapping MBs. The ability to separate overlapping MBs allows use of higher contrast agent concentrations and reduces US image acquisition time. Herein we propose a fully convolutional neural network (CNN) architecture to perform the operations of MB detection as well as localization in a single model. Termed SRUSnet, the network is based on the MobileNetV3 architecture modified for 3-D input data, minimal convergence time, and high-resolution data output using a flexible regression head. Also, we propose to combine linear B-mode US imaging and nonlinear contrast pulse sequencing (CPS) which has been shown to increase MB detection and further reduce the US image acquisition time. The network was trained within silicodata and tested onin vitrodata from a tissue-mimicking flow phantom, and onin vivodata from the rat hind limb (N = 3). Images were collected with a programmable US system (Vantage 256, Verasonics Inc., Kirkland, WA) using an L11-4v linear array transducer. The network exceeded 99.9% detection accuracy onin silicodata. The average localization accuracy was smaller than the resolution of a pixel (i.e.λ/8). The average processing time on a Nvidia GeForce 2080Ti GPU was 64.5 ms for a 128 × 128-pixel image.
Collapse
Affiliation(s)
- Katherine G Brown
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America
| | | | - Arthur David Redfern
- Department of Computer Science, University of Texas at Dallas, Richardson, TX, United States of America
| | - Kenneth Hoyt
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America
| |
Collapse
|
60
|
Rousou C, Schuurmans CCL, Urtti A, Mastrobattista E, Storm G, Moonen C, Kaarniranta K, Deckers R. Ultrasound and Microbubbles for the Treatment of Ocular Diseases: From Preclinical Research towards Clinical Application. Pharmaceutics 2021; 13:pharmaceutics13111782. [PMID: 34834196 PMCID: PMC8624665 DOI: 10.3390/pharmaceutics13111782] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 10/08/2021] [Accepted: 10/09/2021] [Indexed: 12/26/2022] Open
Abstract
The unique anatomy of the eye and the presence of various biological barriers make efficacious ocular drug delivery challenging, particularly in the treatment of posterior eye diseases. This review focuses on the combination of ultrasound and microbubbles (USMB) as a minimally invasive method to improve the efficacy and targeting of ocular drug delivery. An extensive overview is given of the in vitro and in vivo studies investigating the mechanical effects of ultrasound-driven microbubbles aiming to: (i) temporarily disrupt the blood–retina barrier in order to enhance the delivery of systemically administered drugs into the eye, (ii) induce intracellular uptake of anticancer drugs and macromolecules and (iii) achieve targeted delivery of genes, for the treatment of ocular malignancies and degenerative diseases. Finally, the safety and tolerability aspects of USMB, essential for the translation of USMB to the clinic, are discussed.
Collapse
Affiliation(s)
- Charis Rousou
- Departments of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.C.L.S.); (E.M.); (G.S.)
- Division of Imaging and Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands; (C.M.); (R.D.)
- Correspondence:
| | - Carl C. L. Schuurmans
- Departments of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.C.L.S.); (E.M.); (G.S.)
- Department of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands
| | - Arto Urtti
- School of Pharmacy, Faculty of Health Sciences, University of Eastern Finland, 70210 Kuopio, Finland;
- Division of Pharmaceutical Biosciences, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014 Helsinki, Finland
- Institute of Chemistry, St. Petersburg State University, Universitetskii Pr. 26, Petrodvorets, 198504 St. Petersburg, Russia
| | - Enrico Mastrobattista
- Departments of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.C.L.S.); (E.M.); (G.S.)
| | - Gert Storm
- Departments of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Heidelberglaan 8, 3584 CS Utrecht, The Netherlands; (C.C.L.S.); (E.M.); (G.S.)
- Department of Biomaterials Science and Technology, University of Twente, 7500 AE Enschede, The Netherlands
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119228, Singapore
| | - Chrit Moonen
- Division of Imaging and Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands; (C.M.); (R.D.)
| | - Kai Kaarniranta
- Department of Ophthalmology, Kuopio University Hospital, P.O. Box 100, 70029 Kuopio, Finland;
- Department of Ophthalmology, Institute of Clinical Medicine, University of Eastern Finland, P.O. Box 1627, 70211 Kuopio, Finland
| | - Roel Deckers
- Division of Imaging and Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands; (C.M.); (R.D.)
| |
Collapse
|
61
|
Wei L, Wahyulaksana G, Meijlink B, Ramalli A, Noothout E, Verweij MD, Boni E, Kooiman K, van der Steen AFW, Tortoli P, de Jong N, Vos HJ. High Frame Rate Volumetric Imaging of Microbubbles Using a Sparse Array and Spatial Coherence Beamforming. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:3069-3081. [PMID: 34086570 DOI: 10.1109/tuffc.2021.3086597] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate. In this study, we demonstrate with a prototype sparse array probe and a diverging wave transmission strategy, that a uniform transmission field can be achieved. With the implementation of a spatial coherence beamformer, the background clutter signal can be effectively suppressed, leading to a signal to background ratio improvement of 25 dB. With this approach, we demonstrate the volumetric visualization of single microbubbles in a tissue-mimicking phantom as well as vasculature mapping in a live chicken embryo chorioallantoic membrane.
Collapse
|
62
|
Fouad M, El Ghany MAA, Huebner M, Schmitz G. A Deep Learning Signal-Based Approach to Fast Harmonic Imaging. 2021 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) 2021. [DOI: 10.1109/ius52206.2021.9593348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
63
|
Bader KB, Wallach EL, Shekhar H, Flores-Guzman F, Halpern HJ, Hernandez SL. Estimating the mechanical energy of histotripsy bubble clouds with high frame rate imaging. Phys Med Biol 2021; 66:10.1088/1361-6560/ac155d. [PMID: 34271560 PMCID: PMC10680990 DOI: 10.1088/1361-6560/ac155d] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 07/16/2021] [Indexed: 11/11/2022]
Abstract
Mechanical ablation with the focused ultrasound therapy histotripsy relies on the generation and action of bubble clouds. Despite its critical role for ablation, quantitative metrics of bubble activity to gauge treatment outcomes are still lacking. Here, plane wave imaging was used to track the dissolution of bubble clouds following initiation with the histotripsy pulse. Information about the rate of change in pixel intensity was coupled with an analytic diffusion model to estimate bubble size. Accuracy of the hybrid measurement/model was assessed by comparing the predicted and measured dissolution time of the bubble cloud. Good agreement was found between predictions and measurements of bubble cloud dissolution times in agarose phantoms and murine subcutaneous SCC VII tumors. The analytic diffusion model was extended to compute the maximum bubble size as well as energy imparted to the tissue due to bubble expansion. Regions within tumors predicted to have undergone strong bubble expansion were collocated with ablation. Further, the dissolution time was found to correlate with acoustic emissions generated by the bubble cloud during histotripsy insonation. Overall, these results indicate a combination of modeling and high frame rate imaging may provide means to quantify mechanical energy imparted to the tissue due to bubble expansion for histotripsy.
Collapse
Affiliation(s)
- Kenneth B Bader
- Department of Radiology, University of Chicago, Chicago, IL, United States of America
| | - Emily L Wallach
- Department of Radiology, University of Chicago, Chicago, IL, United States of America
| | - Himanshu Shekhar
- Discipline of Electrical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | | | - Howard J Halpern
- Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL United States of America
| | - Sonia L Hernandez
- Department of Surgery, University of Chicago, Chicago, IL, United States of America
| |
Collapse
|
64
|
Clark A, Bonilla S, Suo D, Shapira Y, Averkiou M. Microbubble-Enhanced Heating: Exploring the Effect of Microbubble Concentration and Pressure Amplitude on High-Intensity Focused Ultrasound Treatments. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2296-2309. [PMID: 33985825 PMCID: PMC8243806 DOI: 10.1016/j.ultrasmedbio.2021.03.035] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 03/25/2021] [Accepted: 03/29/2021] [Indexed: 05/11/2023]
Abstract
High-intensity focused ultrasound (HIFU) is a non-invasive tool that can be used for targeted thermal ablation treatments. Currently, HIFU is clinically approved for treatment of uterine fibroids, various cancers, and certain brain applications. However, for brain applications such as essential tremors, HIFU can only be used to treat limited areas confined to the center of the brain because of geometrical limitations (shape of the transducer and skull). A major obstacle to advancing this technology is the inability to treat non-central brain locations without causing damage to the skin and/or skull. Previous research has indicated that cavitation-induced bubbles or microbubble contrast agents can be used to enhance HIFU treatments by increasing ablation regions and shortening acoustic exposures at lower acoustic pressures. However, little research has been done to explore the interplay between microbubble concentration and pressure amplitude on HIFU treatments. We developed an in vitro experimental setup to study lesion formation at three different acoustic pressures and three microbubble concentrations. Real-time ultrasound imaging was integrated to monitor initial microbubble concentration and subsequent behavior during the HIFU treatments. Depending on the pressure used for the HIFU treatment, there was an optimal concentration of microbubbles that led to enhanced heating in the focal area. If the concentration of microbubbles was too high, the treatment was detrimentally affected because of non-linear attenuation by the pre-focal microbubbles. Additionally, the real-time ultrasound imaging provided a reliable method to monitor microbubble activity during the HIFU treatments, which is important for translation to in vivo HIFU applications with microbubbles.
Collapse
Affiliation(s)
- Alicia Clark
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - Sierra Bonilla
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - Dingjie Suo
- Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | | | - Michalakis Averkiou
- Department of Bioengineering, University of Washington, Seattle, Washington, USA.
| |
Collapse
|
65
|
Batchelor DV, Armistead FJ, Ingram N, Peyman SA, Mclaughlan JR, Coletta PL, Evans SD. Nanobubbles for therapeutic delivery: Production, stability and current prospects. Curr Opin Colloid Interface Sci 2021. [DOI: 10.1016/j.cocis.2021.101456] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
66
|
Krafft MP, Riess JG. Therapeutic oxygen delivery by perfluorocarbon-based colloids. Adv Colloid Interface Sci 2021; 294:102407. [PMID: 34120037 DOI: 10.1016/j.cis.2021.102407] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 03/18/2021] [Accepted: 03/25/2021] [Indexed: 02/06/2023]
Abstract
After the protocol-related indecisive clinical trial of Oxygent, a perfluorooctylbromide/phospholipid nanoemulsion, in cardiac surgery, that often unduly assigned the observed untoward effects to the product, the development of perfluorocarbon (PFC)-based O2 nanoemulsions ("blood substitutes") has come to a low. Yet, significant further demonstrations of PFC O2-delivery efficacy have continuously been reported, such as relief of hypoxia after myocardial infarction or stroke; protection of vital organs during surgery; potentiation of O2-dependent cancer therapies, including radio-, photodynamic-, chemo- and immunotherapies; regeneration of damaged nerve, bone or cartilage; preservation of organ grafts destined for transplantation; and control of gas supply in tissue engineering and biotechnological productions. PFC colloids capable of augmenting O2 delivery include primarily injectable PFC nanoemulsions, microbubbles and phase-shift nanoemulsions. Careful selection of PFC and other colloid components is critical. The basics of O2 delivery by PFC nanoemulsions will be briefly reminded. Improved knowledge of O2 delivery mechanisms has been acquired. Advanced, size-adjustable O2-delivering nanoemulsions have been designed that have extended room-temperature shelf-stability. Alternate O2 delivery options are being investigated that rely on injectable PFC-stabilized microbubbles or phase-shift PFC nanoemulsions. The latter combine prolonged circulation in the vasculature, capacity for penetrating tumor tissues, and acute responsiveness to ultrasound and other external stimuli. Progress in microbubble and phase-shift emulsion engineering, control of phase-shift activation (vaporization), understanding and control of bubble/ultrasound/tissue interactions is discussed. Control of the phase-shift event and of microbubble size require utmost attention. Further PFC-based colloidal systems, including polymeric micelles, PFC-loaded organic or inorganic nanoparticles and scaffolds, have been devised that also carry substantial amounts of O2. Local, on-demand O2 delivery can be triggered by external stimuli, including focused ultrasound irradiation or tumor microenvironment. PFC colloid functionalization and targeting can help adjust their properties for specific indications, augment their efficacy, improve safety profiles, and expand the range of their indications. Many new medical and biotechnological applications involving fluorinated colloids are being assessed, including in the clinic. Further uses of PFC-based colloidal nanotherapeutics will be briefly mentioned that concern contrast diagnostic imaging, including molecular imaging and immune cell tracking; controlled delivery of therapeutic energy, as for noninvasive surgical ablation and sonothrombolysis; and delivery of drugs and genes, including across the blood-brain barrier. Even when the fluorinated colloids investigated are designed for other purposes than O2 supply, they will inevitably also carry and deliver a certain amount of O2, and may thus be considered for O2 delivery or co-delivery applications. Conversely, O2-carrying PFC nanoemulsions possess by nature a unique aptitude for 19F MR imaging, and hence, cell tracking, while PFC-stabilized microbubbles are ideal resonators for ultrasound contrast imaging and can undergo precise manipulation and on-demand destruction by ultrasound waves, thereby opening multiple theranostic opportunities.
Collapse
Affiliation(s)
- Marie Pierre Krafft
- University of Strasbourg, Institut Charles Sadron (CNRS), 23 rue du Loess, 67034 Strasbourg, France.
| | - Jean G Riess
- Harangoutte Institute, 68160 Ste Croix-aux-Mines, France
| |
Collapse
|
67
|
Yang J, Cherin E, Yin J, Newsome IG, Kierski TM, Pang G, Carnevale CA, Dayton PA, Foster FS, Demore CEM. Characterization of an Array-Based Dual-Frequency Transducer for Superharmonic Contrast Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2419-2431. [PMID: 33729934 PMCID: PMC8459708 DOI: 10.1109/tuffc.2021.3065952] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Superharmonic imaging with dual-frequency imaging systems uses conventional low-frequency ultrasound transducers on transmit, and high-frequency transducers on receive to detect higher order harmonic signals from microbubble contrast agents, enabling high-contrast imaging while suppressing clutter from background tissues. Current dual-frequency imaging systems for superharmonic imaging have been used for visualizing tumor microvasculature, with single-element transducers for each of the low- and high-frequency components. However, the useful field of view is limited by the fixed focus of single-element transducers, while image frame rates are limited by the mechanical translation of the transducers. In this article, we introduce an array-based dual-frequency transducer, with low-frequency and high-frequency arrays integrated within the probe head, to overcome the limitations of single-channel dual-frequency probes. The purpose of this study is to evaluate the line-by-line high-frequency imaging and superharmonic imaging capabilities of the array-based dual-frequency probe for acoustic angiography applications in vitro and in vivo. We report center frequencies of 1.86 MHz and 20.3 MHz with -6 dB bandwidths of 1.2 MHz (1.2-2.4 MHz) and 14.5 MHz (13.3-27.8 MHz) for the low- and high-frequency arrays, respectively. With the proposed beamforming schemes, excitation pressure was found to range from 336 to 458 kPa at its azimuthal foci. This was sufficient to induce nonlinear scattering from microbubble contrast agents. Specifically, in vitro contrast channel phantom imaging and in vivo xenograft mouse tumor imaging by this probe with superharmonic imaging showed contrast-to-tissue ratio improvements of 17.7 and 16.2 dB, respectively, compared to line-by-line micro-ultrasound B-mode imaging.
Collapse
|
68
|
Kitano M, Yamashita Y, Kamata K, Ang TL, Imazu H, Ohno E, Hirooka Y, Fusaroli P, Seo DW, Napoléon B, Teoh AYB, Kim TH, Dietrich CF, Wang HP, Kudo M. The Asian Federation of Societies for Ultrasound in Medicine and Biology (AFSUMB) Guidelines for Contrast-Enhanced Endoscopic Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1433-1447. [PMID: 33653627 DOI: 10.1016/j.ultrasmedbio.2021.01.030] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 01/25/2021] [Accepted: 01/28/2021] [Indexed: 06/12/2023]
Abstract
The Asian Federation of Societies for Ultrasound in Medicine and Biology aimed to provide information on techniques and indications for contrast-enhanced harmonic endoscopic ultrasound (CH-EUS), and to create statements including the level of recommendation. These statements are based on current scientific evidence reviewed by a Consensus Panel of 15 internationally renowned experts. The reliability of clinical questions was measured by agreement rates after voting. Six statements were made on techniques, including suitable contrast agents for CH-EUS, differences between contrast agents, setting of mechanical index, dual imaging and duration and phases for observation. Thirteen statements were made on indications, including pancreatic solid masses, pancreatic cancer staging, pancreatic cystic lesions and mural nodules, detection of subtle pancreatic lesions, gallbladder sludge and polyps, hepatic lesions, lymph nodes, subepithelial lesions, visceral vascular diseases, guidance of fine needle aspiration and evaluation for local therapy. These international expert consensus guidelines will assist endosonographers in conducting CH-EUS according to evidence-based information.
Collapse
Affiliation(s)
- Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan.
| | - Yasunobu Yamashita
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Ken Kamata
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan
| | - Tiing Leong Ang
- Department of Gastroenterology and Hepatology, Changi General Hospital, Singapore
| | - Hiroo Imazu
- Division of Gastroenterology and Hepatology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Eizaburo Ohno
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School, Nagoya, Japan
| | - Yoshiki Hirooka
- Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University, Aichi, Japan
| | - Pietro Fusaroli
- Gastroenterology Unit, Department of Medical and Surgical Sciences, University of Bologna/Hospital of Imola, Imola, Italy
| | - Dong-Wan Seo
- Department of Gastroenterology, Asan Medical Centre, Seoul, Korea
| | - Bertrand Napoléon
- Department of Gastroenterology, Jean Mermoz Private Hospital, Ramsay Generale de Sante, Lyon, France
| | - Anthony Yuen Bun Teoh
- Department of Surgery, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong, China
| | - Tae Hyeon Kim
- Department of Internal Medicine, Wonkwang University College of Medicine, Iksan, South Korea
| | - Christoph F Dietrich
- Department of Internal Medicine (DAIM), Hirslanden Kliniken Beau Site, Salem und Permanence Bern, Switzerland
| | - Hsiu-Po Wang
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan
| |
Collapse
|
69
|
Thielen NT, Kleinsasser AA, Freeling JL. Myocardial contrast echocardiography assessment of mouse myocardial infarction: comparison of kinetic parameters with conventional methods. PeerJ 2021; 9:e11500. [PMID: 34141476 DOI: 10.7717/peerj.11500/supp-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 05/02/2021] [Indexed: 05/25/2023] Open
Abstract
This study explores the use of a minimally invasive assessment of myocardial infarction (MI) in mice using myocardial contrast echocardiography (MCE). The technique uses existing equipment and software readily available to the average researcher. C57/BL6 mice were randomized to either MI or sham surgery and evaluated using MCE at 1- or 2-weeks post-surgery. Size-isolated microbubbles were injected via retro-orbital catheter where their non-linear characteristics were utilized to produce the two-dimensional parameters of Wash-in-Rate and the Peak Enhancement, indicative of relative myocardial perfusion and blood volume, respectively. Three-dimensional cardiac reconstructions allowed the calculation of the Percent Agent, interpreted as the vascularity of the entire myocardium. These MCE parameters were compared to conventional assessments including M-Mode, strain analysis, and 2,3,5-Triphenyltetrazolium chloride (TTC) staining. Except for the Wash-in-Rate 2-week cohort, all MCE parameters were able to differentiate sham-operated versus MI animals and correlated with TTC staining (P < 0.05). MCE parameters were also able to identify MI group animals which failed to develop infarctions as determined by TTC staining. This study provides basic validation of these MCE parameters to detect MI in mice complementary to conventional methods while providing additional hemodynamic information in vivo.
Collapse
Affiliation(s)
- Nicholas T Thielen
- Sanford School of Medicine, University of South Dakota, Vermillion, South Dakota, United States
| | - Adison A Kleinsasser
- Research Computing Group, University of South Dakota, Vermillion, South Dakota, United States
| | - Jessica L Freeling
- Basic Biomedical Sciences, University of South Dakota, Vermillion, South Dakota, United States
| |
Collapse
|
70
|
Thielen NT, Kleinsasser AA, Freeling JL. Myocardial contrast echocardiography assessment of mouse myocardial infarction: comparison of kinetic parameters with conventional methods. PeerJ 2021; 9:e11500. [PMID: 34141476 PMCID: PMC8176928 DOI: 10.7717/peerj.11500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 05/02/2021] [Indexed: 01/14/2023] Open
Abstract
This study explores the use of a minimally invasive assessment of myocardial infarction (MI) in mice using myocardial contrast echocardiography (MCE). The technique uses existing equipment and software readily available to the average researcher. C57/BL6 mice were randomized to either MI or sham surgery and evaluated using MCE at 1- or 2-weeks post-surgery. Size-isolated microbubbles were injected via retro-orbital catheter where their non-linear characteristics were utilized to produce the two-dimensional parameters of Wash-in-Rate and the Peak Enhancement, indicative of relative myocardial perfusion and blood volume, respectively. Three-dimensional cardiac reconstructions allowed the calculation of the Percent Agent, interpreted as the vascularity of the entire myocardium. These MCE parameters were compared to conventional assessments including M-Mode, strain analysis, and 2,3,5-Triphenyltetrazolium chloride (TTC) staining. Except for the Wash-in-Rate 2-week cohort, all MCE parameters were able to differentiate sham-operated versus MI animals and correlated with TTC staining (P < 0.05). MCE parameters were also able to identify MI group animals which failed to develop infarctions as determined by TTC staining. This study provides basic validation of these MCE parameters to detect MI in mice complementary to conventional methods while providing additional hemodynamic information in vivo.
Collapse
Affiliation(s)
- Nicholas T Thielen
- Sanford School of Medicine, University of South Dakota, Vermillion, South Dakota, United States
| | - Adison A Kleinsasser
- Research Computing Group, University of South Dakota, Vermillion, South Dakota, United States
| | - Jessica L Freeling
- Basic Biomedical Sciences, University of South Dakota, Vermillion, South Dakota, United States
| |
Collapse
|
71
|
Lai TY, Averkiou MA. Linear Signal Cancellation of Nonlinear Pulsing Schemes in a Verasonics Research Scanner. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:1721-1728. [PMID: 33428569 PMCID: PMC8142865 DOI: 10.1109/tuffc.2021.3050481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Contrast-enhanced ultrasound (CEUS) is a real-time imaging technique that allows the visualization of organ and tumor microcirculation by utilizing the nonlinear response of microbubbles. Nonlinear pulsing schemes are used exclusively in CEUS imaging modes in modern scanners. One important aspect of nonlinear pulsing schemes is the near-complete elimination of the linear signals that originate from tissue. Up until now, no study has investigated the performance of Verasonics scanners in eliminating the linear signals during CEUS and, by extension, the optimal pulsing sequences for performing CEUS. The aim of this article was to investigate linear signal cancellation of the Verasonics scanner performing nonlinear pulsing schemes with two different probes (L7-4 linear array and C5-2 convex array). We have considered two pulsing schemes: pulse inversion (PI) and amplitude modulation (AM). We have also compared our results from the Verasonics scanner with a clinical scanner (Philips iU22). We found that the linear signal cancellation of the transmitted pulse by Verasonics scanner was ~40 dB in AM mode and ~30 dB in PI mode when operated at 0.06 MI. The linear signal cancellation performance of Verasonics scanner was comparable with Philips iU22 scanner in focused AM mode and on average 3 dB better than Philips iU22 scanner in focused PI mode.
Collapse
|
72
|
Özdemir İ, Johnson K, Mohr-Allen S, Peak KE, Varner V, Hoyt K. Three-dimensional visualization and improved quantification with super-resolution ultrasound imaging - validation framework for analysis of microvascular morphology using a chicken embryo model. Phys Med Biol 2021; 66:085008. [PMID: 33765676 PMCID: PMC8463964 DOI: 10.1088/1361-6560/abf203] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 03/25/2021] [Indexed: 12/20/2022]
Abstract
The purpose of this study was to improve the morphological analysis of microvascular networks depicted in three-dimensional (3D) super-resolution ultrasound (SR-US) images. This was supported by qualitative and quantitative validation by comparison to matched brightfield microscopy and traditional B-mode ultrasound (US) images. Contrast-enhanced US (CEUS) images were collected using a preclinical US scanner (Vevo 3100, FUJIFILM VisualSonics Inc.) equipped with an MX250 linear array transducer. CEUS imaging was performed after administration of a microbubble (MB) contrast agent into the vitelline network of a developing chicken embryo. Volume data was collected by mechanically scanning the US transducer throughout a tissue volume-of-interest in 90μm step increments. CEUS images were collected at each increment and stored as in-phase/quadrature data (2000 frames at 152 frames per sec). SR-US images were created for each cross-sectional plane using established data processing methods. All SR-US images were then used to reconstruct a final 3D volume for vessel diameter (VD) quantification and for surface rendering. VD quantification from the 3D SR-US data exhibited an average error of 6.1% ± 6.0% when compared with matched brightfield microscopy images, whereas measurements from B-mode US images had an average error of 77.1% ± 68.9%. Volume and surface renderings in 3D space enabled qualitative validation and improved visualization of small vessels below the axial resolution of the US system. Overall, 3D SR-US image reconstructions depicted the microvascular network of the developing chicken embryos. Improved visualization of isolated vessels and quantification of microvascular morphology from SR-US images achieved a considerably greater accuracy compared to B-mode US measurements.
Collapse
Affiliation(s)
- İpek Özdemir
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America
| | - Kenneth Johnson
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America
| | - Shelby Mohr-Allen
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America
| | - Kara E Peak
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America
| | - Victor Varner
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America
| | - Kenneth Hoyt
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX, United States of America
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, United States of America
| |
Collapse
|
73
|
van Elburg B, Collado-Lara G, Bruggert GW, Segers T, Versluis M, Lajoinie G. Feedback-controlled microbubble generator producing one million monodisperse bubbles per second. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:035110. [PMID: 33820052 DOI: 10.1063/5.0032140] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 02/15/2021] [Indexed: 06/12/2023]
Abstract
Monodisperse lipid-coated microbubbles are a promising route to unlock the full potential of ultrasound contrast agents for medical diagnosis and therapy. Here, we present a stand-alone lab-on-a-chip instrument that allows microbubbles to be formed with high monodispersity at high production rates. Key to maintaining a long-term stable, controlled, and safe operation of the microfluidic device with full control over the output size distribution is an optical transmission-based measurement technique that provides real-time information on the production rate and bubble size. We feed the data into a feedback loop and demonstrate that this system can control the on-chip bubble radius (2.5 μm-20 μm) and the production rate up to 106 bubbles/s. The freshly formed phospholipid-coated bubbles stabilize after their formation to a size approximately two times smaller than their initial on-chip bubble size without loss of monodispersity. The feedback control technique allows for full control over the size distribution of the agent and can aid the development of microfluidic platforms operated by non-specialist end users.
Collapse
Affiliation(s)
- Benjamin van Elburg
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Gonzalo Collado-Lara
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Gert-Wim Bruggert
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Tim Segers
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Michel Versluis
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| |
Collapse
|
74
|
Fedak A, Chrzan R, Chukwu O, Urbanik A. Ultrasound methods of imaging atherosclerotic plaque in carotid arteries: examinations using contrast agents. J Ultrason 2020; 20:e191-e200. [PMID: 33365156 PMCID: PMC7705485 DOI: 10.15557/jou.2020.0032] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 07/11/2020] [Indexed: 11/22/2022] Open
Abstract
The primary technique for detecting the presence and monitoring the development of carotid atherosclerotic plaque is ultrasound. The development of ultrasound techniques has made it possible to precisely visualise not only blood flow, but also vessel walls, including atherosclerotic plaque. Contrast-enhanced ultrasound examination enables one to make an objective observation of atherosclerotic plaque neovascularisation, clearly indicating active inflammation, which is an inherent feature of vulnerable (unstable) plaque. Depending on the examination method used, it is possible to precisely visualise different components of the plaque and its behaviour during blood flow through the vessel lumen or through the neovessels of the plaque, and, consequently, determine the possible presence of inflammation, which is a defining feature of plaque stability. The full utilisation of physical phenomena that underlie contrast-enhanced ultrasound will bring further enormous progress of diagnostic and probably also therapeutic methods for carotid atherosclerosis. The selection of the right examination method significantly accelerates diagnosis and adequate classification of plaque, and makes it possible to monitor the progression of atherosclerosis. However, one needs to bear in mind that ultrasound remains a very subjective method. The success of contrast-enhanced ultrasound also depends on the skills and experience of the examiner. Current attempts at increasing the objectivity of contrast-enhanced ultrasound examination using artificial intelligence will make it possible in the future to make a definitive evaluation of atherosclerotic plaque stability. This will allow one to assess the risk of ischaemic stroke adequately.
Collapse
Affiliation(s)
- Andrzej Fedak
- Department of Radiology, Jagiellonian University Medical College, Kraków, Poland
| | - Robert Chrzan
- Department of Radiology, Jagiellonian University Medical College, Kraków, Poland
| | - Ositadima Chukwu
- Student Science Club, Department of Radiology, Jagiellonian University Medical College, Kraków, Poland
| | - Andrzej Urbanik
- Department of Radiology, Jagiellonian University Medical College, Kraków, Poland
| |
Collapse
|
75
|
Lu J, Zhou P, Jin C, Xu L, Zhu X, Lian Q, Gong X. Diagnostic Value of Contrast-Enhanced Ultrasonography With SonoVue in the Differentiation of Benign and Malignant Breast Lesions: A Meta-Analysis. Technol Cancer Res Treat 2020; 19:1533033820971583. [PMID: 33308040 PMCID: PMC7739090 DOI: 10.1177/1533033820971583] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE A meta-analysis was conducted to evaluate the diagnostic performance of contrast-enhanced ultrasonography using the contrast agent SonoVue to differentiate benign from malignant breast lesions. METHOD A comprehensive search of the literature was performed using the Embase, PubMed, and Web of Science databases to retrieve studies published before February 2020. Data were extracted, and pooled sensitivity, specificity, and diagnostic odds ratios were calculated with meta-analysis software. Heterogeneity was evaluated via the Q test and I2 statistic. Meta-regression and subgroup analyses were applied to evaluate potential sources of heterogeneity. Publication bias was assessed using the Deeks' funnel plot asymmetry test. A summary receiver operating characteristic curve (SROC) was constructed. RESULTS A total of 27 studies including 5378 breast lesions subjected to CEUS examination with SonoVue were included in the meta-analysis. The pooled sensitivity and specificity values were 0.90 (95% confidence interval [CI], 0.88-0.91; inconsistency index [I2] = 75.7%) and 0.83 (95% CI, 0.82-0.85; I2 = 91.0%), respectively. The pooled diagnostic odds ratio was 48.35% (95% CI, 31.22-74.89; I2 = 77.6%). The area under the summary receiver operating characteristic curve (AUC) was 0.9354. Meta-regression analysis revealed the region of patient residence and dose of contrast agent as potential sources of heterogeneity (P < .01). Subgroup analysis showed a higher area under the summary receiver operating characteristic curve for European and higher contrast agent dose subgroups (P < .05). CONCLUSION Contrast-enhanced ultrasonography with SonoVue displays high sensitivity, specificity, and accuracy when differentiating benign from malignant breast lesions. Despite its current limitations, this technique presents a promising tool for diagnosing breast lesions in clinical practice.
Collapse
Affiliation(s)
- Jianghao Lu
- Department of Ultrasound, First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China
| | - Peng Zhou
- Department of Ultrasound, First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China
| | - Chunchun Jin
- Department of Ultrasound, First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China
| | - Lifeng Xu
- Department of Ultrasound, First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China
| | - Xiaomin Zhu
- Department of Ultrasound, First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China
| | - Qingshu Lian
- Department of Ultrasound, First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China
| | - Xuehao Gong
- Department of Ultrasound, First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China
| |
Collapse
|
76
|
Helbert A, Gaud E, Segers T, Botteron C, Frinking P, Jeannot V. Monodisperse versus Polydisperse Ultrasound Contrast Agents: In Vivo Sensitivity and safety in Rat and Pig. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3339-3352. [PMID: 33008649 DOI: 10.1016/j.ultrasmedbio.2020.07.031] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 07/24/2020] [Accepted: 07/30/2020] [Indexed: 05/21/2023]
Abstract
Recent advances in the field of monodisperse microbubble synthesis by flow focusing allow for the production of foam-free, highly concentrated and monodisperse lipid-coated microbubble suspensions. It has been found that in vitro, such monodisperse ultrasound contrast agents (UCAs) improve the sensitivity of contrast-enhanced ultrasound imaging. Here, we present the first in vivo study in the left ventricle of rat and pig with this new monodisperse bubble agent. We systematically characterize the acoustic sensitivity and safety of the agent at an imaging frequency of 2.5 MHz as compared with three commercial polydisperse UCAs (SonoVue/Lumason, Definity/Luminity and Optison) and one research-grade polydisperse agent with the same shell composition as the monodisperse bubbles. The monodisperse microbubbles, which had a diameter of 4.2 μm, crossed the pulmonary vasculature, and their echo signal could be measured at least as long as that of the polydisperse UCAs, indicating that microfluidically formed monodisperse microbubbles are stable in vivo. Furthermore, it was found that the sensitivity of the monodisperse agent, expressed as the mean echo power per injected bubble, was at least 10 times higher than that of the polydisperse UCAs. Finally, the safety profile of the monodisperse microbubble suspension was evaluated by injecting 400 and 2000 times the imaging dose, and neither physiologic nor pathologic changes were found, which is a first indication that monodisperse lipid-coated microbubbles formed by flow focusing are safe for in vivo use. The more uniform acoustic response and corresponding increased imaging sensitivity of the monodisperse agent may boost emerging applications of microbubbles and ultrasound such as molecular imaging and therapy.
Collapse
Affiliation(s)
- Alexandre Helbert
- Bracco Suisse S.A., Route de la Galaise 31, 1228 Plan-les-Ouates, Switzerland
| | - Emmanuel Gaud
- Bracco Suisse S.A., Route de la Galaise 31, 1228 Plan-les-Ouates, Switzerland
| | - Tim Segers
- Physics of Fluids Group, MESA + Institute for Nanotechnology, Technical Medical (TechMed) Center, University of Twente, Enschede, The Netherlands; Former employee of Bracco Suisse S.A
| | | | | | - Victor Jeannot
- Bracco Suisse S.A., Route de la Galaise 31, 1228 Plan-les-Ouates, Switzerland.
| |
Collapse
|
77
|
Vos HJ, Voorneveld JD, Groot Jebbink E, Leow CH, Nie L, van den Bosch AE, Tang MX, Freear S, Bosch JG. Contrast-Enhanced High-Frame-Rate Ultrasound Imaging of Flow Patterns in Cardiac Chambers and Deep Vessels. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2875-2890. [PMID: 32843233 DOI: 10.1016/j.ultrasmedbio.2020.07.022] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 07/17/2020] [Accepted: 07/20/2020] [Indexed: 06/11/2023]
Abstract
Cardiac function and vascular function are closely related to the flow of blood within. The flow velocities in these larger cavities easily reach 1 m/s, and generally complex spatiotemporal flow patterns are involved, especially in a non-physiologic state. Visualization of such flow patterns using ultrasound can be greatly enhanced by administration of contrast agents. Tracking the high-velocity complex flows is challenging with current clinical echographic tools, mostly because of limitations in signal-to-noise ratio; estimation of lateral velocities; and/or frame rate of the contrast-enhanced imaging mode. This review addresses the state of the art in 2-D high-frame-rate contrast-enhanced echography of ventricular and deep-vessel flow, from both technological and clinical perspectives. It concludes that current advanced ultrasound equipment is technologically ready for use in human contrast-enhanced studies, thus potentially leading to identification of the most clinically relevant flow parameters for quantifying cardiac and vascular function.
Collapse
Affiliation(s)
- Hendrik J Vos
- Biomedical Engineering, Department of Cardiology, Erasmus University Medical Center, Rotterdam, The Netherlands; Medical Imaging, Department of Imaging Physics, Applied Sciences, Delft University of Technology, Delft, The Netherlands.
| | - Jason D Voorneveld
- Biomedical Engineering, Department of Cardiology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Erik Groot Jebbink
- M3i: Multi-modality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands; Department of Vascular Surgery, Rijnstate Hospital, Arnhem, The Netherlands
| | - Chee Hau Leow
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Luzhen Nie
- School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom
| | | | - Meng-Xing Tang
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Steven Freear
- School of Electronic and Electrical Engineering, University of Leeds, Leeds, United Kingdom
| | - Johan G Bosch
- Biomedical Engineering, Department of Cardiology, Erasmus University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
78
|
Keller SB, Suo D, Wang YN, Kenerson H, Yeung RS, Averkiou MA. Image-Guided Treatment of Primary Liver Cancer in Mice Leads to Vascular Disruption and Increased Drug Penetration. Front Pharmacol 2020; 11:584344. [PMID: 33101038 PMCID: PMC7554611 DOI: 10.3389/fphar.2020.584344] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 09/07/2020] [Indexed: 12/14/2022] Open
Abstract
Despite advances in interventional procedures and chemotherapeutic drug development, hepatocellular carcinoma (HCC) is still the fourth leading cause of cancer-related deaths worldwide with a <30% 5-year survival rate. This poor prognosis can be attributed to the fact that HCC most commonly occurs in patients with pre-existing liver conditions, rendering many treatment options too aggressive. Patient survival rates could be improved by a more targeted approach. Ultrasound-induced cavitation can provide a means for overcoming traditional barriers defining drug uptake. The goal of this work was to evaluate preclinical efficacy of image-guided, cavitation-enabled drug delivery with a clinical ultrasound scanner. To this end, ultrasound conditions (unique from those used in imaging) were designed and implemented on a Philips EPIQ and S5-1 phased array probe to produced focused ultrasound for cavitation treatment. Sonovue® microbubbles which are clinically approved as an ultrasound contrast agent were used for both imaging and cavitation treatment. A genetically engineered mouse model was bred and used as a physiologically relevant preclinical analog to human HCC. It was observed that image-guided and targeted microbubble cavitation resulted in selective disruption of the tumor blood flow and enhanced doxorubicin uptake and penetration. Histology results indicate that no gross morphological damage occurred as a result of this process. The combination of these effects may be exploited to treat HCC and other challenging malignancies and could be implemented with currently available ultrasound scanners and reagents.
Collapse
Affiliation(s)
- Sara B Keller
- Department of Bioengineering, University of Washington, Seattle, WA, United States
| | - Dingjie Suo
- Department of Bioengineering, University of Washington, Seattle, WA, United States
| | - Yak-Nam Wang
- Applied Physics Laboratory, University of Washington, Seattle, WA, United States
| | - Heidi Kenerson
- Department of Surgery, University of Washington, Seattle, WA, United States
| | - Raymond S Yeung
- Department of Surgery, University of Washington, Seattle, WA, United States
| | | |
Collapse
|
79
|
Oezdemir I, Wessner CE, Shaw C, Eisenbrey JR, Hoyt K. Tumor Vascular Networks Depicted in Contrast-Enhanced Ultrasound Images as a Predictor for Transarterial Chemoembolization Treatment Response. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2276-2286. [PMID: 32561069 PMCID: PMC7725382 DOI: 10.1016/j.ultrasmedbio.2020.05.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 04/14/2020] [Accepted: 05/12/2020] [Indexed: 05/25/2023]
Abstract
Hepatocellular carcinoma (HCC) is prevalent worldwide. Among the various therapeutic options, transarterial chemoembolization (TACE) can be applied to the tumor vascular network by restricting the nutrients and oxygen supply to the tumor. Unique morphologic properties of this network may provide information predictive of future therapeutic responses, which would be significant for decision making during treatment planning. The extraction of morphologic features from the tumor vascular network depicted in abdominal contrast-enhanced ultrasound (CEUS) images faces several challenges, such as organ motion, limited resolution caused by clutter signal and segmentation of the vascular structures at multiple scales. In this study, we present an image processing and analysis approach for the prediction of HCC response to TACE treatment using clinical CEUS images and known pathologic responses. This method focuses on addressing the challenges of CEUS by incorporating a two-stage motion correction strategy, clutter signal removal, vessel enhancement at multiple scales and machine learning for predictive modeling. The morphologic features, namely, number of vessels (NV), number of bifurcations (NB), vessel to tissue ratio (VR), mean vessel length, tortuosity and diameter, from tumor architecture were quantified from CEUS images of 36 HCC patients before TACE treatment. Our analysis revealed that NV, NB and VR are the dominant features for the prediction of long-term TACE response. The model had an accuracy of 86% with a sensitivity and specificity of 89% and 82%, respectively. Reliable prediction of the TACE therapy response using CEUS-derived image features may help to provide personalized therapy planning, which will ultimately improve patient outcomes.
Collapse
Affiliation(s)
- Ipek Oezdemir
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas, USA
| | - Corrine E Wessner
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Colette Shaw
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - John R Eisenbrey
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Kenneth Hoyt
- Department of Bioengineering, University of Texas at Dallas, Richardson, Texas, USA.
| |
Collapse
|
80
|
Evaluation of the Reproducibility of Bolus Transit Quantification With Contrast-Enhanced Ultrasound Across Multiple Scanners and Analysis Software Packages—A Quantitative Imaging Biomarker Alliance Study. Invest Radiol 2020; 55:643-656. [DOI: 10.1097/rli.0000000000000702] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
81
|
Brown K, Hoyt K. Simultaneous Evalulation of Contrast Pulse Sequences for Super-Resolution Ultrasound Imaging - Preliminary In Vitro and In Vivo Results. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:2121-2124. [PMID: 33018425 DOI: 10.1109/embc44109.2020.9176087] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Super-resolution ultrasound imaging (SR-US) has enabled a tenfold improvement in resolution of the microvasculature with clinical application in many disease processes such as cancer, diabetes and cardiovascular disease. Plane wave ultrasound (US) platforms in turn are capable of the very high frame rates needed to track microbubble (MB) contrast agents used in SR-US. Both B-mode US imaging and contrast enhanced US imaging (CEUS) have been effectively used in SR-US, with B-mode US having higher signal-to-noise ratio (SNR) and CEUS providing higher contrast-to-tissue ratio (CTR). Lengthy imaging time needed for SR-US to allow perfusion and MB detection is an impediment to clinical adoption. Both SNR and CTR improvements can enhance SR-US imaging by enhancing the detection of MBs thus reducing imaging time. This study simultaneously evaluated nonlinear contrast pulse sequences (CPS) employing different amplitude modulation (AM) and pulse inversion (PI) nonlinear CEUS imaging techniques as well as combinations of the two, (AMPI) with B-mode US imaging. The objective was to improve the detection rate of MB during SR-US. Imaging was performed in vitro and in vivo in the rat hind limb using a Vantage 256 research scanner (Verasonics Inc.). Comparisons of four CPS compositions with B-mode US imaging was made based on the number of MB detected and localized in SR-US images. The use of a PI nonlinear CEUS imaging strategy improved SR-US imaging by increasing the number of MB detected in a sequence of frames by an average of 28.3% and up to 52.6% over a B-mode US imaging strategy, which would decrease imaging time accordingly.
Collapse
|