51
|
Wu S, Zhou L, Chen C, Shi LA, Zhu S, Zhang C, Meng D, Huang Z, Li J, Hu Y, Wu D. Photothermal Actuation of Diverse Liquids on an Fe 3O 4-Doped Slippery Surface for Electric Switching and Cell Culture. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:13915-13922. [PMID: 31566979 DOI: 10.1021/acs.langmuir.9b02068] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The photoinduced manipulation of liquids on a slippery lubricant-infused porous surface (SLIPS) has attracted a tremendous amount of attention because of its merits of contactless stimulation and excellent spatial and temporal control. However, tedious fabrication methods by a combination of template transfer and fluorination for a photothermal-material-doped SLIPS and the lack of deeper systematically quantitative analysis with respect to droplet hydrokinetics are greatly perplexing in both academic research and industrial applications. Here we demonstrate a kind of Fe3O4-doped SLIPS by one-step femtosecond laser cross-scanning, which can readily steer diverse liquids toward arbitrary directions with a fast velocity of up to 1.15 mm/s in the presence of a unilateral NIR stimulus. The underlying mechanism is that the wettability gradient force (Fwet-grad) induced by the temperature gradient arising from asymmetric near-infrared-irradiation (NIR) loading would be generated within 1 s to actuate a targeted droplet's sliding behavior. Through tuning the NIR irradiating sites, we can slide a targeted droplet with controllable directions and routes. On the basis of fundamental physics, we have quantitatively analyzed the relationship among Fe3O4-doped content, lubricant rheological performance, droplet wettability variations, Fwet-grad, and the sliding velocity for diverse liquid species. Accordingly, we can remotely steer liquid droplets to realize the on-off state of an electrical circuit on demand, the droplet fusion of a microfluidic reactor, and the culture/inhibition of biological cells.
Collapse
|
52
|
Han S, Zhang Q, Zhang X, Liu X, Lu L, Wei J, Li Y, Wang Y, Zheng G. A digital microfluidic diluter-based microalgal motion biosensor for marine pollution monitoring. Biosens Bioelectron 2019; 143:111597. [DOI: 10.1016/j.bios.2019.111597] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2019] [Revised: 08/11/2019] [Accepted: 08/13/2019] [Indexed: 01/24/2023]
|
53
|
Xin Z, Skrydstrup T. Flüssigmurmeln: Eine vielversprechende und vielseitige Plattform für Miniaturisierte Chemische Reaktionen. Angew Chem Int Ed Engl 2019. [DOI: 10.1002/ange.201905204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Zhuo Xin
- Institute for Advanced StudyNanchang University Xuefu Road 999 Nanchang City 330031 China
| | - Troels Skrydstrup
- Institute for Advanced StudyNanchang University Xuefu Road 999 Nanchang City 330031 China
- Carbon Dioxide Activation Center (CADIAC)Department of Chemistry and the Interdisciplinary Nanoscience Center (iNANO)Aarhus University Gustav Wieds Vej 14 8000 Aarhus C Denmark
| |
Collapse
|
54
|
Xin Z, Skrydstrup T. Liquid Marbles: A Promising and Versatile Platform for Miniaturized Chemical Reactions. Angew Chem Int Ed Engl 2019; 58:11952-11954. [DOI: 10.1002/anie.201905204] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Indexed: 11/07/2022]
Affiliation(s)
- Zhuo Xin
- Institute for Advanced StudyNanchang University Xuefu Road 999 Nanchang City 330031 China
| | - Troels Skrydstrup
- Institute for Advanced StudyNanchang University Xuefu Road 999 Nanchang City 330031 China
- Carbon Dioxide Activation Center (CADIAC)Department of Chemistry and the Interdisciplinary Nanoscience Center (iNANO)Aarhus University Gustav Wieds Vej 14 8000 Aarhus C Denmark
| |
Collapse
|
55
|
Zhang Q, Zhang X, Zhang X, Jiang L, Yin J, Zhang P, Han S, Wang Y, Zheng G. A feedback-controlling digital microfluidic fluorimetric sensor device for simple and rapid detection of mercury (II) in costal seawater. MARINE POLLUTION BULLETIN 2019; 144:20-27. [PMID: 31179989 DOI: 10.1016/j.marpolbul.2019.04.063] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2018] [Revised: 04/16/2019] [Accepted: 04/25/2019] [Indexed: 06/09/2023]
Abstract
By combination of miniaturization potential of digital microfluidics (DMF) and sensitivity of fluorescence probe, an integrated sensor device has been initially constructed for mercury detection in coastal waters. The actuation feature of the detecting target, seawater droplet, which remains unclear, was basically explored. To overcome a potential risk of driven failure, induced by diversity ion ingredients in seawater, a feedback control loop was included into control system. Analyzing method for coastal waters was well established on DMF, which showed satisfied stability and selectivity in Hg sensing under high salinity condition, with the sensitivity of Hg2+ at the parts per billion level and total testing time less than 20s. With the advantages of being fast, amenable to automation and low cost, this device is promising for the formation of simple and rapid sensor device, especially for a routine monitoring and emergency detection of Hg/or other metals in coastal waters.
Collapse
Affiliation(s)
- Qian Zhang
- Chemical and Environmental Engineering Institute, Dalian University, Dalian 116622, China; Environmental Micro Total Analysis Lab, Dalian University, Dalian 116622, China
| | - Xingcai Zhang
- Department of Physics, School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, United States
| | - Xiaolin Zhang
- Chemical and Environmental Engineering Institute, Dalian University, Dalian 116622, China; Environmental Micro Total Analysis Lab, Dalian University, Dalian 116622, China
| | - Lan Jiang
- Chemical and Environmental Engineering Institute, Dalian University, Dalian 116622, China; Environmental Micro Total Analysis Lab, Dalian University, Dalian 116622, China
| | - Jingmei Yin
- Chemical and Environmental Engineering Institute, Dalian University, Dalian 116622, China
| | - Peng Zhang
- National Marine Environmental Monitoring Center, Dalian 116600, China; Environmental Micro Total Analysis Lab, Dalian University, Dalian 116622, China
| | - Shuang Han
- Chemical and Environmental Engineering Institute, Dalian University, Dalian 116622, China; Environmental Micro Total Analysis Lab, Dalian University, Dalian 116622, China
| | - Yunhua Wang
- Medical School, Dalian University, Dalian 116622, China; Environmental Micro Total Analysis Lab, Dalian University, Dalian 116622, China.
| | - Guoxia Zheng
- Chemical and Environmental Engineering Institute, Dalian University, Dalian 116622, China; Environmental Micro Total Analysis Lab, Dalian University, Dalian 116622, China.
| |
Collapse
|
56
|
Geng H, Cho SK. Antifouling digital microfluidics using lubricant infused porous film. LAB ON A CHIP 2019; 19:2275-2283. [PMID: 31184676 DOI: 10.1039/c9lc00289h] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Electrowetting-driven digital (droplet-based) microfluidics has a tremendous impact on lab-on-a-chip applications. However, the biofouling problem impedes the real applications of such digital microfluidics. Here we report antifouling digital microfluidics by introducing lubricant infused porous film to electrowetting (more exactly, electrowetting on dielectric or EWOD). Such film minimizes direct contact between droplets and the solid surface but provides liquid-liquid contact between droplets and the lubricant liquid, which thus prevents unspecific adsorption of biomolecules to the solid surface. We demonstrate the compatibility of the lubricant infused film with EWOD to transport bio droplets. This configuration shows robust and high performance even for long cyclic operations without fouling in a wide range of concentrations of protein solutions. In addition, a variety of conductive droplets, including deionized (DI) water, saline, protein solution, DNA solution, sheep blood, milk, ionic liquid and honey, are examined, similarly showing high performance in cyclic transportations. In addition, using the same electrode patterns used in EWOD, transportations of dielectric (non-conductive) droplets including light crude oil, propylene carbonate and alcohol are also achieved. Such capability of droplet handling without fouling will certainly benefit the practical applications of digital microfluidics in droplet handling, sampling, reaction, diagnosis in clinic medicine, biotechnology and chemistry fields.
Collapse
Affiliation(s)
- Hongyao Geng
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, PA 15261, USA.
| | | |
Collapse
|
57
|
Kerr CB, Epps RW, Abolhasani M. A low-cost, non-invasive phase velocity and length meter and controller for multiphase lab-in-a-tube devices. LAB ON A CHIP 2019; 19:2107-2113. [PMID: 31049546 DOI: 10.1039/c9lc00296k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Opportunities for accessible microfluidic device integration have sharply grown with the rise of readily available lab-in-a-tube strategies. Herein, we present a facile, non-invasive, plug-and-play phase velocity and length measuring strategy for rapid deployment onto tube-based microfluidic systems, enabling quick and accurate residence (reaction) time measurement and tuning. Our approach utilizes inexpensive off-the-shelf optical phase sensors and requires no prior knowledge of the fluid composition or physical properties. Compared to camera-based measurements in fluoropolymer tubing, the optical phase sensor-based technique shows mean absolute percentage errors of 1.3% for velocity and 3.3% for length. Utilizing the developed multiphase flow monitoring technique, we screen the accessible parameter space of gas-liquid segmented flows. To further demonstrate the functionality of this process monitoring strategy, we implement two feedback controllers to establish simultaneous setpoint control for phase velocity and length. Next, to showcase the effectiveness and versatility of the developed multiphase flow process controller, we apply it to systematic studies of the effect of liquid slug velocity (controlling precursor mixing timescale) on the colloidal synthesis of cesium lead tribromide nanocrystals. By varying the liquid slug velocity and maintaining constant precursor composition, liquid slug length, and residence time, we observe a bandgap tunability from 2.43 eV (510 nm) to 2.52 eV (494 nm).
Collapse
Affiliation(s)
- Corwin B Kerr
- Department of Chemical and Biomolecular Engineering, North Carolina State University, 911 Partners Way, Raleigh, USA.
| | | | | |
Collapse
|
58
|
Eilenberger C, Spitz S, Bachmann BEM, Ehmoser EK, Ertl P, Rothbauer M. The Usual Suspects 2019: of Chips, Droplets, Synthesis, and Artificial Cells. MICROMACHINES 2019; 10:E285. [PMID: 31035574 PMCID: PMC6562886 DOI: 10.3390/mi10050285] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 04/24/2019] [Accepted: 04/26/2019] [Indexed: 12/03/2022]
Abstract
Synthetic biology aims to understand fundamental biological processes in more detail than possible for actual living cells. Synthetic biology can combat decomposition and build-up of artificial experimental models under precisely controlled and defined environmental and biochemical conditions. Microfluidic systems can provide the tools to improve and refine existing synthetic systems because they allow control and manipulation of liquids on a micro- and nanoscale. In addition, chip-based approaches are predisposed for synthetic biology applications since they present an opportune technological toolkit capable of fully automated high throughput and content screening under low reagent consumption. This review critically highlights the latest updates in microfluidic cell-free and cell-based protein synthesis as well as the progress on chip-based artificial cells. Even though progress is slow for microfluidic synthetic biology, microfluidic systems are valuable tools for synthetic biology and may one day help to give answers to long asked questions of fundamental cell biology and life itself.
Collapse
Affiliation(s)
- Christoph Eilenberger
- Institute of Applied Synthetic Chemistry, Institute of Chemical Technologies and Analytics, Faculty of Technical Chemistry, Vienna University of Technology, A-1060 Vienna, Austria.
| | - Sarah Spitz
- Institute of Applied Synthetic Chemistry, Institute of Chemical Technologies and Analytics, Faculty of Technical Chemistry, Vienna University of Technology, A-1060 Vienna, Austria.
| | - Barbara Eva Maria Bachmann
- Austrian Cluster for Tissue Regeneration, Vienna, Austria; Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Allgemeine Unfallversicherungsanstalt (AUVA) Research Centre, A-1200 Vienna, Austria.
| | - Eva Kathrin Ehmoser
- Institute of Synthetic Bioarchitectures, Department of Nanobiotechnology, University of Natural Resources and Life Sciences Vienna, A-1190 Vienna, Austria.
| | - Peter Ertl
- Institute of Applied Synthetic Chemistry, Institute of Chemical Technologies and Analytics, Faculty of Technical Chemistry, Vienna University of Technology, A-1060 Vienna, Austria.
| | - Mario Rothbauer
- Institute of Applied Synthetic Chemistry, Institute of Chemical Technologies and Analytics, Faculty of Technical Chemistry, Vienna University of Technology, A-1060 Vienna, Austria.
| |
Collapse
|
59
|
Zhong Z, Li Z, Chakrabarty K, Ho TY, Lee CY. Micro-Electrode-Dot-Array Digital Microfluidic Biochips: Technology, Design Automation, and Test Techniques. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:292-313. [PMID: 30571645 DOI: 10.1109/tbcas.2018.2886952] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Digital microfluidic biochips (DMFBs) are being increasingly used for DNA sequencing, point-of-care clinical diagnostics, and immunoassays. DMFBs based on a micro-electrode-dot-array (MEDA) architecture have recently been proposed, and fundamental droplet manipulations, e.g., droplet mixing and splitting, have also been experimentally demonstrated on MEDA biochips. There can be thousands of microelectrodes on a single MEDA biochip, and the fine-grained control of nanoliter volumes of biochemical samples and reagents is also enabled by this technology. MEDA biochips offer the benefits of real-time sensitivity, lower cost, easy system integration with CMOS modules, and full automation. This review paper first describes recent design tools for high-level synthesis and optimization of map bioassay protocols on a MEDA biochip. It then presents recent advances in scheduling of fluidic operations, placement of fluidic modules, droplet-size-aware routing, adaptive error recovery, sample preparation, and various testing techniques. With the help of these tools, biochip users can concentrate on the development of nanoscale bioassays, leaving details of chip optimization and implementation to software tools.
Collapse
|
60
|
Coudron L, McDonnell MB, Munro I, McCluskey DK, Johnston ID, Tan CK, Tracey MC. Fully integrated digital microfluidics platform for automated immunoassay; A versatile tool for rapid, specific detection of a wide range of pathogens. Biosens Bioelectron 2019; 128:52-60. [DOI: 10.1016/j.bios.2018.12.014] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 11/29/2018] [Accepted: 12/11/2018] [Indexed: 11/17/2022]
|
61
|
Ahmadi F, Samlali K, Vo PQN, Shih SCC. An integrated droplet-digital microfluidic system for on-demand droplet creation, mixing, incubation, and sorting. LAB ON A CHIP 2019; 19:524-535. [PMID: 30633267 DOI: 10.1039/c8lc01170b] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Droplet microfluidics is a technique that has the ability to compartmentalize reactions in sub nano- (or pico-) liter volumes that can potentially enable millions of distinct biological assays to be performed on individual cells. In a typical droplet microfluidic system, droplets are manipulated by pressure-based flows. This has limited the fluidic operations that can be performed in these devices. Digital microfluidics is an alternative microfluidic paradigm with precise control and manipulation over individual droplets. Here, we implement an integrated droplet-digital microfluidic (which we call 'ID2M') system in which common fluidic operations (i.e. droplet generation, cell encapsulation, droplet merging and mixing, droplet trapping and incubation, and droplet sorting) can be performed. With the addition of electrodes, we have been able to create droplets on-demand, tune their volumes on-demand, and merge and mix several droplets to produce a dilution series. Moreover, this device can trap and incubate droplets for 24 h that can consequently be sorted and analyzed in multiple n-ary channels (as opposed to typical binary channels). The ID2M platform has been validated as a robust on-demand screening system by sorting fluorescein droplets of different concentration with an efficiency of ∼96%. The utility of the new system is further demonstrated by culturing and sorting tolerant yeast mutants and wild-type yeast cells in ionic liquid based on their growth profiles. This new platform for both droplet and digital microfluidics has the potential to be used for screening different conditions on-chip and for applications like directed evolution.
Collapse
Affiliation(s)
- Fatemeh Ahmadi
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec, Canada.
| | | | | | | |
Collapse
|
62
|
Zhang J, Chen J, Peng S, Peng S, Zhang Z, Tong Y, Miller PW, Yan XP. Emerging porous materials in confined spaces: from chromatographic applications to flow chemistry. Chem Soc Rev 2019; 48:2566-2595. [DOI: 10.1039/c8cs00657a] [Citation(s) in RCA: 82] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Porous materials confined within capillary columns/microfluidic devices are discussed, and progress in chromatographic and membrane separations and catalysis is reviewed.
Collapse
Affiliation(s)
- Jianyong Zhang
- Sun Yat-Sen University
- MOE Laboratory of Polymeric Composite and Functional Materials
- Guangzhou 510275
- China
| | - Junxing Chen
- Sun Yat-Sen University
- MOE Laboratory of Polymeric Composite and Functional Materials
- Guangzhou 510275
- China
| | - Sheng Peng
- Sun Yat-Sen University
- MOE Laboratory of Polymeric Composite and Functional Materials
- Guangzhou 510275
- China
| | - Shuyin Peng
- Sun Yat-Sen University
- MOE Laboratory of Polymeric Composite and Functional Materials
- Guangzhou 510275
- China
| | - Zizhe Zhang
- Sun Yat-Sen University
- MOE Laboratory of Polymeric Composite and Functional Materials
- Guangzhou 510275
- China
| | - Yexiang Tong
- Sun Yat-Sen University
- MOE Laboratory of Polymeric Composite and Functional Materials
- Guangzhou 510275
- China
| | | | - Xiu-Ping Yan
- State Key Laboratory of Food Science and Technology
- International Joint Laboratory on Food Safety
- School of Food Science and Technology
- Jiangnan University
- Wuxi 214122
| |
Collapse
|
63
|
Razu ME, Kim J. Digital microfluidics using a differentially polarized interface (DPI) to enhance translational force. LAB ON A CHIP 2018; 18:3293-3302. [PMID: 30264074 DOI: 10.1039/c8lc00652k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Direct current (DC)-digital microfluidics (DMF) enables the manipulation of droplets to revolutionize medical diagnostics, environmental assays, and fundamental biology. However, DC-DMF requires high voltages to generate droplet motion, which often breaks dielectric layers at the micro/nano scale, causing electrolysis. To minimize these issues, oil-fillers are commonly used to decrease the voltage requirement by reducing the surface tension of the droplet to the surrounding fluid. However, these oil-fillers increase DC-DMF complexity and decrease versatility. In this study, by adapting a differentially polarized interface (DPI) to generate an effective electromechanical force, the voltage required to manipulate a droplet was reduced from 600 V to 85 V without an oil-filler or special dielectric materials. By analyzing the temporal profiles of the contact angles during droplet motion under this DPI condition, this study, for the first time, distinguished the contributions of electrowetting and electromechanical forces to the translational movement of droplets. Dominant contribution of electrowetting is observed at the initial stage of the droplet translation with 52.8% reduction in the advancing contact angle and 20% reduction in the receding contact angle. However, after saturation in the temporal change of the contact angle, the effect of electrowetting contribution gradually decreases and electromechanical forces predominate. DPI-based digital microfluidics reduces the overall cost and complexity of stand-alone DC-DMF platforms, enabling filler-less and low-voltage applications for manipulating a wide range of liquid samples.
Collapse
Affiliation(s)
- Md Enayet Razu
- Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas 79409, USA.
| | | |
Collapse
|
64
|
Development of Coplanar Electro-Wetting Based Microfluidic Sorter to Select Micro-Particles in High Volume Throughput at Milliliter Amount within Twenty Minutes. SENSORS 2018; 18:s18092941. [PMID: 30181484 PMCID: PMC6164432 DOI: 10.3390/s18092941] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2018] [Revised: 08/28/2018] [Accepted: 09/01/2018] [Indexed: 11/17/2022]
Abstract
This paper reports the work of developing one coplanar microfluidic sorter while using the electro-wetting on dielectrics (EWOD) technique. When connected with delivery capillary to receive sample solution containing micro-particles, this device can select about 10 micro-particles in high volume throughput of milliliter amount within 20 min, to potentially match the requirement of efficiently determining the low amounts of bacteria in concentrated food and environmental samples, of which the typical bacteria density is 10 colony forming unit or less, much smaller than that of clinical pathogen samples. This coplanar T-shape EWOD device contains two fluidic channels, one inlet channel and the other collection channel stemmed from the middle of inlet channel. When the solution droplet falls from the delivery capillary to the entrance end of inlet channel, the droplet is driven to the intersection of two channels. The droplet containing fluorescent particle will be diverted to the lower channel to collect. Otherwise, the non-fluorescent droplet keeps moving toward the other end of inlet channel to waste zone. The particle fluorescence is collected through microscope lens to detect with one photomultiplier tube. The detected signals trigger the personal computer control board to active each EWOD electrode to direct the droplet moving directions. When the solution of 1 mL containing about 10 fluorescent micro-particles is delivered into this sorting device, nearly all the particles were correctly directed into collection zone in 20 min.
Collapse
|
65
|
Sathyanarayanan G, Haapala M, Kiiski I, Sikanen T. Digital microfluidic immobilized cytochrome P450 reactors with integrated inkjet-printed microheaters for droplet-based drug metabolism research. Anal Bioanal Chem 2018; 410:6677-6687. [PMID: 30073515 PMCID: PMC6132693 DOI: 10.1007/s00216-018-1280-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 06/27/2018] [Accepted: 07/17/2018] [Indexed: 01/23/2023]
Abstract
We report the development and characterization of digital microfluidic (DMF) immobilized enzyme reactors (IMERs) for studying cytochrome P450 (CYP)-mediated drug metabolism on droplet scale. The on-chip IMERs consist of porous polymer (thiol-ene) monolith plugs prepared in situ by photopolymerization and functionalized with recombinant CYP1A1 isoforms (an important detoxification route for many drugs and other xenobiotics). The DMF devices also incorporate inexpensive, inkjet-printed microheaters for on-demand regio-specific heating of the IMERs to physiological temperature, which is crucial for maintaining the activity of the temperature-sensitive CYP reaction. For on-chip monitoring of the CYP activity, the DMF devices were combined with a commercial well-plate reader, and a custom fluorescence quantification method was developed for detection of the chosen CYP1A1 model activity (ethoxyresorufin-O-deethylation). The reproducibility of the developed assay was examined with the help of ten parallel CYP-IMERs. All CYP-IMERs provided statistically significant difference (in fluorescence response) compared to any of the negative controls (including room-temperature reactions). The average (n = 10) turnover rate was 20.3 ± 9.0 fmol resorufin per minute. Via parallelization, the concept of the droplet-based CYP-IMER developed in this study provides a viable approach to rapid and low-cost prediction of the metabolic clearance of new chemical entities in vitro.
Collapse
Affiliation(s)
- Gowtham Sathyanarayanan
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
| | - Markus Haapala
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
| | - Iiro Kiiski
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland
| | - Tiina Sikanen
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
| |
Collapse
|
66
|
Millington D, Norton S, Singh R, Sista R, Srinivasan V, Pamula V. Digital microfluidics comes of age: high-throughput screening to bedside diagnostic testing for genetic disorders in newborns. Expert Rev Mol Diagn 2018; 18:701-712. [PMID: 30004274 PMCID: PMC6481615 DOI: 10.1080/14737159.2018.1495076] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Digital microfluidics (DMF) is an emerging technology with the appropriate metrics for application to newborn and high-risk screening for inherited metabolic disease and other conditions that benefit from early treatment. Areas covered: This review traces the development of electrowetting-based DMF technology toward the fulfillment of its promise to provide an inexpensive platform to conduct enzymatic assays and targeted biomarker assays at the bedside. The high-throughput DMF platform, referred to as SEEKER®, was recently authorized by the United States Food and Drug Administration to screen newborns for four lysosomal storage disorders (LSDs) and is deployed in newborn screening programs in the United States. The development of reagents and methods for LSD screening and results from screening centers are reviewed. Preliminary results from a more compact DMF device, to perform disease-specific test panels from small volumes of blood, are also reviewed. Literature for this review was sourced using principal author and subject searches in PubMed. Expert commentary: Newborn screening is a vital and highly successful public health program. DMF technology adds value to the current testing platforms that will benefit apparently healthy newborns with underlying genetic disorders and infants at-risk for conditions that present with symptoms in the newborn period.
Collapse
Affiliation(s)
- David Millington
- Department of Pediatrics, Duke University Medical Center, Durham, NC
| | | | | | | | | | | |
Collapse
|
67
|
Wang P, Kricka LJ. Current and Emerging Trends in Point-of-Care Technology and Strategies for Clinical Validation and Implementation. Clin Chem 2018; 64:1439-1452. [PMID: 29884677 DOI: 10.1373/clinchem.2018.287052] [Citation(s) in RCA: 64] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 05/11/2018] [Indexed: 12/14/2022]
Abstract
BACKGROUND Point-of-care technology (POCT) provides actionable information at the site of care to allow rapid clinical decision-making. With healthcare emphasis shifting toward precision medicine, population health, and chronic disease management, the potential impact of POCT continues to grow, and several prominent POCT trends have emerged or strengthened in the last decade. CONTENT This review summarizes current and emerging trends in POCT, including technologies approved or cleared by the Food and Drug Administration or in development. Technologies included have either impacted existing clinical diagnostics applications (e.g., continuous monitoring and targeted nucleic acid testing) or are likely to impact diagnostics delivery in the near future. The focus is limited to in vitro diagnostics applications, although in some sections, technologies beyond in vitro diagnostics are also included given the commonalities (e.g., ultrasound plug-ins for smart phones). For technologies in development (e.g., wearables, noninvasive testing, mass spectrometry and nuclear magnetic resonance, paper-based diagnostics, nanopore-based devices, and digital microfluidics), we also discuss their potential clinical applications and provide perspectives on strategies beyond technological and analytical proof of concept, with the end goal of clinical implementation and impact. SUMMARY The field of POCT has witnessed strong growth over the past decade, as evidenced by new clinical or consumer products or research and development directions. Combined with the appropriate strategies for clinical needs assessment, validation, and implementation, these and future POCTs may significantly impact care delivery and associated outcomes and costs.
Collapse
Affiliation(s)
- Ping Wang
- William Pepper Laboratory, University of Pennsylvania Heath System, and the Department of Pathology and Laboratory Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA.
| | - Larry J Kricka
- William Pepper Laboratory, University of Pennsylvania Heath System, and the Department of Pathology and Laboratory Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
68
|
Khilko Y, Weyman PD, Glass JI, Adams MD, McNeil MA, Griffin PB. DNA assembly with error correction on a droplet digital microfluidics platform. BMC Biotechnol 2018; 18:37. [PMID: 29859085 PMCID: PMC5984785 DOI: 10.1186/s12896-018-0439-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Accepted: 04/24/2018] [Indexed: 12/02/2022] Open
Abstract
Background Custom synthesized DNA is in high demand for synthetic biology applications. However, current technologies to produce these sequences using assembly from DNA oligonucleotides are costly and labor-intensive. The automation and reduced sample volumes afforded by microfluidic technologies could significantly decrease materials and labor costs associated with DNA synthesis. The purpose of this study was to develop a gene assembly protocol utilizing a digital microfluidic device. Toward this goal, we adapted bench-scale oligonucleotide assembly methods followed by enzymatic error correction to the Mondrian™ digital microfluidic platform. Results We optimized Gibson assembly, polymerase chain reaction (PCR), and enzymatic error correction reactions in a single protocol to assemble 12 oligonucleotides into a 339-bp double- stranded DNA sequence encoding part of the human influenza virus hemagglutinin (HA) gene. The reactions were scaled down to 0.6-1.2 μL. Initial microfluidic assembly methods were successful and had an error frequency of approximately 4 errors/kb with errors originating from the original oligonucleotide synthesis. Relative to conventional benchtop procedures, PCR optimization required additional amounts of MgCl2, Phusion polymerase, and PEG 8000 to achieve amplification of the assembly and error correction products. After one round of error correction, error frequency was reduced to an average of 1.8 errors kb− 1. Conclusion We demonstrated that DNA assembly from oligonucleotides and error correction could be completely automated on a digital microfluidic (DMF) platform. The results demonstrate that enzymatic reactions in droplets show a strong dependence on surface interactions, and successful on-chip implementation required supplementation with surfactants, molecular crowding agents, and an excess of enzyme. Enzymatic error correction of assembled fragments improved sequence fidelity by 2-fold, which was a significant improvement but somewhat lower than expected compared to bench-top assays, suggesting an additional capacity for optimization. Electronic supplementary material The online version of this article (10.1186/s12896-018-0439-9) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Yuliya Khilko
- Stanford Genome Technology Center, Stanford University, 3165 Porter Drive, Palo Alto, CA, 94304, USA.,Department of Biomedical, Chemical and Materials Engineering, San Jose State University, 1 Washington Sq, San Jose, CA, 95192, USA
| | - Philip D Weyman
- J. Craig Venter Institute, 4120 Capricorn Lane, La Jolla, CA, 92037, USA
| | - John I Glass
- J. Craig Venter Institute, 4120 Capricorn Lane, La Jolla, CA, 92037, USA
| | - Mark D Adams
- J. Craig Venter Institute, 4120 Capricorn Lane, La Jolla, CA, 92037, USA
| | - Melanie A McNeil
- Department of Biomedical, Chemical and Materials Engineering, San Jose State University, 1 Washington Sq, San Jose, CA, 95192, USA
| | - Peter B Griffin
- Stanford Genome Technology Center, Stanford University, 3165 Porter Drive, Palo Alto, CA, 94304, USA.
| |
Collapse
|
69
|
Farzbod A, Moon H. Integration of reconfigurable potentiometric electrochemical sensors into a digital microfluidic platform. Biosens Bioelectron 2018; 106:37-42. [DOI: 10.1016/j.bios.2018.01.048] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 01/17/2018] [Accepted: 01/23/2018] [Indexed: 01/02/2023]
|
70
|
Banerjee U, Sen AK. Shape evolution and splitting of ferrofluid droplets on a hydrophobic surface in the presence of a magnetic field. SOFT MATTER 2018; 14:2915-2922. [PMID: 29610807 DOI: 10.1039/c7sm02312j] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We elucidate the phenomena of dynamic wetting, shape evolution and splitting of ferrofluid (FF) droplets on a hydrophobic surface under the influence of a magnetic field. In the case of a FF droplet interacting with a magnetic field, both surface energy and magnetic energy contribute to the total Gibb's free energy and hence the wetting phenomena. The nanoparticles in the FF droplet migrate and get accumulated at the apex of the droplet which enhances the magnetic interaction causing large deformation of the droplet. The FF droplet deformation and subsequent splitting are governed by the interplay between the magnetic Fm and surface tension Fs forces. The ratio of the forces km = (Fm/Fs) was found to be a function of the magnetic Bond number Bom and non-dimensional gap g* as km ∼ (Bom)0.3(g*)-0.86. Splitting of the FF droplets was observed for km > 1 and for km < 1, an equilibrium droplet shape was observed. The wetting behavior of the FF droplets was found to be strongly dependent on the FF concentration c - concentrated (c = 1.2%) FF droplets exhibit contact line (CL) pinning and decrease in contact angle (CA) θ with time throughout, while diluted (c = 0.6%) FF droplets show a mixed mode (CL pinning followed by constant CA). In splitting of FF droplets, the ratio of the volume of the daughter droplet to that of the parent droplet i.e. (Vd/Vp), was found to decrease with an increase in the parent droplet size Vp.
Collapse
Affiliation(s)
- U Banerjee
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai-600036, India.
| | | |
Collapse
|
71
|
Futai N, Fujita K, Ikuta W. Reconfigurable Microfluidic Channel with Pin-discretized Sidewalls. J Vis Exp 2018. [PMID: 29708554 PMCID: PMC5933500 DOI: 10.3791/57230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Microfluidic components need to have various shapes to realize different key microfluidic functions such as mixing, separation, particle trapping, or reactions. A microfluidic channel that deforms even after fabrication while retaining the channel shape enables high spatiotemporal reconfigurability. This reconfigurability is required in such key microfluidic functions that are difficult to achieve in existing "reconfigurable" or "integrated" microfluidic systems. We describe a method for the fabrication of a microfluidic channel with a deformable sidewall consisting of a laterally aligned array of the ends of rectangular pins. Actuating the pins in their longitudinal directions changes the pins' end positions, and thus, the shape of discretized channel sidewalls.Pin gaps can cause unwanted leakage or adhesion to adjacent pins caused by meniscus forces. To close the pin gaps, we have introduced hydrocarbon-fluoropolymer suspension-based gap filler accompanied by an elastomeric barrier. This reconfigurable microfluidic device can generate strong temporal in-channel displacement flow, or can stop the flow in any region of the channel. This feature will facilitate, on demand, the handling of cells, viscous liquids, gas bubbles, and non-fluids, even if their existence or behavior is unknown at the time of fabrication.
Collapse
Affiliation(s)
- Nobuyuki Futai
- Department of Mechanical Engineering, Shibaura Institute of Technology;
| | - Kenji Fujita
- Department of Mechanical Engineering, Shibaura Institute of Technology
| | - Wataru Ikuta
- Department of Mechanical Engineering, Shibaura Institute of Technology
| |
Collapse
|
72
|
Husser MC, Vo PQN, Sinha H, Ahmadi F, Shih SCC. An Automated Induction Microfluidics System for Synthetic Biology. ACS Synth Biol 2018. [PMID: 29516725 DOI: 10.1021/acssynbio.8b00025] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The expression of a recombinant gene in a host organism through induction can be an extensively manual and labor-intensive procedure. Several methods have been developed to simplify the protocol, but none has fully replaced the traditional IPTG-based induction. To simplify this process, we describe the development of an autoinduction platform based on digital microfluidics. This system consists of a 600 nm LED and a light sensor to enable the real-time monitoring of the optical density (OD) samples coordinated with the semicontinuous mixing of a bacterial culture. A hand-held device was designed as a microbioreactor to culture cells and to measure the OD of the bacterial culture. In addition, it serves as a platform for the analysis of regulated protein expression in E. coli without the requirement of standardized well-plates or pipetting-based platforms. Here, we report for the first time, a system that offers great convenience without the user to physically monitor the culture or to manually add inducer at specific times. We characterized our system by looking at several parameters (electrode designs, gap height, and growth rates) required for an autoinducible system. As a first step, we carried out an automated induction optimization assay using a RFP reporter gene to identify conditions suitable for our system. Next, we used our system to identify active thermophilic β-glucosidase enzymes that may be suitable candidates for biomass hydrolysis. Overall, we believe that this platform may be useful for synthetic biology applications that require regulating and analyzing expression of heterologous genes for strain optimization.
Collapse
Affiliation(s)
- Mathieu C. Husser
- Department of Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
| | - Philippe Q. N. Vo
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G 1M8, Canada
| | - Hugo Sinha
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G 1M8, Canada
| | - Fatemeh Ahmadi
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G 1M8, Canada
| | - Steve C. C. Shih
- Department of Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G 1M8, Canada
| |
Collapse
|
73
|
Serra M, Ferraro D, Pereiro I, Viovy JL, Descroix S. The power of solid supports in multiphase and droplet-based microfluidics: towards clinical applications. LAB ON A CHIP 2017; 17:3979-3999. [PMID: 28948991 DOI: 10.1039/c7lc00582b] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Multiphase and droplet microfluidic systems are growing in relevance in bioanalytical-related fields, especially due to the increased sensitivity, faster reaction times and lower sample/reagent consumption of many of its derived bioassays. Often applied to homogeneous (liquid/liquid) reactions, innovative strategies for the implementation of heterogeneous (typically solid/liquid) processes have recently been proposed. These involve, for example, the extraction and purification of target analytes from complex matrices or the implementation of multi-step protocols requiring efficient washing steps. To achieve this, solid supports such as functionalized particles (micro or nanometric) presenting different physical properties (e.g. magnetic, optical or others) are used for the binding of specific entities. The manipulation of such supports with different microfluidic principles has both led to the miniaturization of existing biomedical protocols and the development of completely new strategies for diagnostics and research. In this review, multiphase and droplet-based microfluidic systems using solid suspensions are presented and discussed with a particular focus on: i) working principles and technological developments of the manipulation strategies and ii) applications, critically discussing the level of maturity of these systems, which can range from initial proofs of concept to real clinical validations.
Collapse
Affiliation(s)
- M Serra
- Laboratoire Physico Chimie Curie, Institut Curie, PSL Research University, CNRS UMR168, Paris, France.
| | | | | | | | | |
Collapse
|
74
|
Gach PC, Iwai K, Kim PW, Hillson NJ, Singh AK. Droplet microfluidics for synthetic biology. LAB ON A CHIP 2017; 17:3388-3400. [PMID: 28820204 DOI: 10.1039/c7lc00576h] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Synthetic biology is an interdisciplinary field that aims to engineer biological systems for useful purposes. Organism engineering often requires the optimization of individual genes and/or entire biological pathways (consisting of multiple genes). Advances in DNA sequencing and synthesis have recently begun to enable the possibility of evaluating thousands of gene variants and hundreds of thousands of gene combinations. However, such large-scale optimization experiments remain cost-prohibitive to researchers following traditional molecular biology practices, which are frequently labor-intensive and suffer from poor reproducibility. Liquid handling robotics may reduce labor and improve reproducibility, but are themselves expensive and thus inaccessible to most researchers. Microfluidic platforms offer a lower entry price point alternative to robotics, and maintain high throughput and reproducibility while further reducing operating costs through diminished reagent volume requirements. Droplet microfluidics have shown exceptional promise for synthetic biology experiments, including DNA assembly, transformation/transfection, culturing, cell sorting, phenotypic assays, artificial cells and genetic circuits.
Collapse
Affiliation(s)
- Philip C Gach
- Technology Division, DOE Joint BioEnergy Institute, Emeryville, California 94608, USA
| | | | | | | | | |
Collapse
|
75
|
Banuprasad TN, Vinay TV, Subash CK, Varghese S, George SD, Varanakkottu SN. Fast Transport of Water Droplets over a Thermo-Switchable Surface Using Rewritable Wettability Gradient. ACS APPLIED MATERIALS & INTERFACES 2017; 9:28046-28054. [PMID: 28750164 DOI: 10.1021/acsami.7b07451] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
In spite of the reported temperature dependent tunability in wettability of poly(N-isopropylacrylamide) (PNIPAAm) surfaces for below and above lower critical solution temperature (32 °C), the transport of water droplets is inhibited by the large contact angle hysteresis. Herein, for the first time, we report on-demand, fast, and reconfigurable droplet manipulation over a PNIPAAm grafted structured polymer surface using temperature-induced wettability gradient. Our study reveals that the PNIPAAm grafted on intrinsically superhydrophobic surfaces exhibit hydrophilic nature with high contact angle hysteresis below 30 °C and superhydrophobic nature with ultralow contact angle hysteresis above 36 °C. The transition region between 30 and 36 °C is characterized by a large change in water contact angle (∼100°) with a concomitant change in contact angle hysteresis. By utilizing this "transport zone" wherein driving forces overcome the frictional forces, we demonstrate macroscopic transport of water drops with a maximum transport velocity of approximately 40 cm/s. The theoretical calculations on the force measurements concur with dominating behavior of driving forces across the transport zone. The tunability in transport velocity by varying the temperature gradient along the surface or the inclination angle of the surface (maximum angle of 15° with a reduced velocity 0.4 mm/s) is also elucidated. In addition, as a practical application, coalescence of water droplets is demonstrated by using the temperature controlled wettability gradient. The presented results are expected to provide new insights on the design and fabrication of smart multifunctional surfaces for applications such as biochemical analysis, self-cleaning, and microfluidics.
Collapse
Affiliation(s)
| | | | | | - Soney Varghese
- School of Nano Science and Technology, National Institute of Technology , Calicut 673 601, India
| | - Sajan D George
- Centre for Applied Nanosciences, Department of Atomic and Molecular Physics, Manipal University , Karnataka 576 104, India
| | | |
Collapse
|
76
|
Abstract
The interdisciplinary research field of microfluidics has the potential to revolutionize current technologies that require the handling of a small amount of fluid, a fast response, low costs and automation. Microfluidic platforms that handle small amounts of liquid have been categorised as continuous-flow microfluidics and digital microfluidics. The first part of this paper discusses the recent advances of the two main and opposing applications of liquid handling in continuous-flow microfluidics: mixing and separation. Mixing and separation are essential steps in most lab-on-a-chip platforms, as sample preparation and detection are required for a variety of biological and chemical assays. The second part discusses the various digital microfluidic strategies, based on droplets and liquid marbles, for the manipulation of discrete microdroplets. More advanced digital microfluidic devices combining electrowetting with other techniques are also introduced. The applications of the emerging field of liquid-marble-based digital microfluidics are also highlighted. Finally, future perspectives on microfluidic liquid handling are discussed.
Collapse
|
77
|
Abstract
Droplet microfluidics generates and manipulates discrete droplets through immiscible multiphase flows inside microchannels. Due to its remarkable advantages, droplet microfluidics bears significant value in an extremely wide range of area. In this review, we provide a comprehensive and in-depth insight into droplet microfluidics, covering fundamental research from microfluidic chip fabrication and droplet generation to the applications of droplets in bio(chemical) analysis and materials generation. The purpose of this review is to convey the fundamentals of droplet microfluidics, a critical analysis on its current status and challenges, and opinions on its future development. We believe this review will promote communications among biology, chemistry, physics, and materials science.
Collapse
Affiliation(s)
- Luoran Shang
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University , Nanjing 210096, China
| | - Yao Cheng
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University , Nanjing 210096, China
| | - Yuanjin Zhao
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University , Nanjing 210096, China
| |
Collapse
|
78
|
Abstract
A digital microfluidic platform manipulates droplets on an open surface. Magnetic digital microfluidics utilizes magnetic forces for actuation and offers unique advantages compared to other digital microfluidic platforms. First, the magnetic particles used in magnetic digital microfluidics have multiple functions. In addition to serving as actuators, they also provide a functional solid substrate for molecule binding, which enables a wide range of applications in molecular diagnostics and immunodiagnostics. Second, magnetic digital microfluidics can be manually operated in a "power-free" manner, which allows for operation in low-resource environments for point-of-care diagnostics where even batteries are considered a luxury item. This review covers research areas related to magnetic digital microfluidics. This paper first summarizes the current development of magnetic digital microfluidics. Various methods of droplet manipulation using magnetic forces are discussed, ranging from conventional magnetic particle-based actuation to the recent development of ferrofluids and magnetic liquid marbles. This paper also discusses several new approaches that use magnetically controlled flexible substrates for droplet manipulation. In addition, we emphasize applications of magnetic digital microfluidics in biosensing and medical diagnostics, and identify the current limitations of magnetic digital microfluidics. We provide a perspective on possible solutions to close these gaps. Finally, the paper discusses the future improvement of magnetic digital microfluidics to explore potential new research directions.
Collapse
Affiliation(s)
- Yi Zhang
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore.
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane, QLD 4111, Australia
| |
Collapse
|
79
|
Zhang Q, Zhang M, Djeghlaf L, Bataille J, Gamby J, Haghiri-Gosnet AM, Pallandre A. Logic digital fluidic in miniaturized functional devices: Perspective to the next generation of microfluidic lab-on-chips. Electrophoresis 2017; 38:953-976. [DOI: 10.1002/elps.201600429] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Revised: 12/19/2016] [Accepted: 12/23/2016] [Indexed: 12/18/2022]
Affiliation(s)
- Qiongdi Zhang
- Centre de Nanosciences et de Nanotechnologies, CNRS UMR-9001, Univ. Paris Sud; Université Paris-Saclay; C2N France
| | - Ming Zhang
- Centre de Nanosciences et de Nanotechnologies, CNRS UMR-9001, Univ. Paris Sud; Université Paris-Saclay; C2N France
| | - Lyas Djeghlaf
- Centre de Nanosciences et de Nanotechnologies, CNRS UMR-9001, Univ. Paris Sud; Université Paris-Saclay; C2N France
| | - Jeanne Bataille
- Institut Galien Paris Sud, CNRS UMR-8612, Univ. Paris Sud; Université Paris-Saclay; Châtenay-Malabry France
| | - Jean Gamby
- Centre de Nanosciences et de Nanotechnologies, CNRS UMR-9001, Univ. Paris Sud; Université Paris-Saclay; C2N France
| | - Anne-Marie Haghiri-Gosnet
- Centre de Nanosciences et de Nanotechnologies, CNRS UMR-9001, Univ. Paris Sud; Université Paris-Saclay; C2N France
| | - Antoine Pallandre
- Laboratoire de Chimie Physique, CNRS UMR-8000, Univ. Paris Sud; Université Paris-Saclay; Orsay France
| |
Collapse
|
80
|
Varma VB, Ray A, Wang ZM, Wang ZP, Ramanujan RV. Droplet Merging on a Lab-on-a-Chip Platform by Uniform Magnetic Fields. Sci Rep 2016; 6:37671. [PMID: 27892475 PMCID: PMC5124862 DOI: 10.1038/srep37671] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Accepted: 11/01/2016] [Indexed: 02/07/2023] Open
Abstract
Droplet microfluidics offers a range of Lab-on-a-chip (LoC) applications. However, wireless and programmable manipulation of such droplets is a challenge. We address this challenge by experimental and modelling studies of uniform magnetic field induced merging of ferrofluid based droplets. Control of droplet velocity and merging was achieved through uniform magnetic field and flow rate ratio. Conditions for droplet merging with respect to droplet velocity were studied. Merging and mixing of colour dye + magnetite composite droplets was demonstrated. Our experimental and numerical results are in good agreement. These studies are useful for wireless and programmable droplet merging as well as mixing relevant to biosensing, bioassay, microfluidic-based synthesis, reaction kinetics, and magnetochemistry.
Collapse
Affiliation(s)
- V B Varma
- School of Materials Science and Engineering, Nanyang Technological University, 639798, Singapore
| | - A Ray
- School of Materials Science and Engineering, Nanyang Technological University, 639798, Singapore
| | - Z M Wang
- School of Materials Science and Engineering, Nanyang Technological University, 639798, Singapore
| | - Z P Wang
- Singapore Institute of Manufacturing Technology, 71 Nanyang Dr, 638075, Singapore
| | - R V Ramanujan
- School of Materials Science and Engineering, Nanyang Technological University, 639798, Singapore
| |
Collapse
|
81
|
Spontaneous assembly of chemically encoded two-dimensional coacervate droplet arrays by acoustic wave patterning. Nat Commun 2016; 7:13068. [PMID: 27708286 PMCID: PMC5059748 DOI: 10.1038/ncomms13068] [Citation(s) in RCA: 84] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 08/31/2016] [Indexed: 01/11/2023] Open
Abstract
The spontaneous assembly of chemically encoded, molecularly crowded, water-rich micro-droplets into periodic defect-free two-dimensional arrays is achieved in aqueous media by a combination of an acoustic standing wave pressure field and in situ complex coacervation. Acoustically mediated coalescence of primary droplets generates single-droplet per node micro-arrays that exhibit variable surface-attachment properties, spontaneously uptake dyes, enzymes and particles, and display spatial and time-dependent fluorescence outputs when exposed to a reactant diffusion gradient. In addition, coacervate droplet arrays exhibiting dynamical behaviour and exchange of matter are prepared by inhibiting coalescence to produce acoustically trapped lattices of droplet clusters that display fast and reversible changes in shape and spatial configuration in direct response to modulations in the acoustic frequencies and fields. Our results offer a novel route to the design and construction of ‘water-in-water' micro-droplet arrays with controllable spatial organization, programmable signalling pathways and higher order collective behaviour. Isolated droplets can be used as micro-reactors, yet it is challenging to operate them functionally in solution and observe chemical exchanges between droplets. Here, Tian et al. use an acoustic trap to assemble water-based micro-droplets into periodic arrays, spontaneously separated from solution media.
Collapse
|
82
|
Evolvable Smartphone-Based Platforms for Point-of-Care In-Vitro Diagnostics Applications. Diagnostics (Basel) 2016; 6:diagnostics6030033. [PMID: 27598208 PMCID: PMC5039567 DOI: 10.3390/diagnostics6030033] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 08/22/2016] [Accepted: 08/23/2016] [Indexed: 11/16/2022] Open
Abstract
The association of smart mobile devices and lab-on-chip technologies offers unprecedented opportunities for the emergence of direct-to-consumer in vitro medical diagnostics applications. Despite their clear transformative potential, obstacles remain to the large-scale disruption and long-lasting success of these systems in the consumer market. For instance, the increasing level of complexity of instrumented lab-on-chip devices, coupled to the sporadic nature of point-of-care testing, threatens the viability of a business model mainly relying on disposable/consumable lab-on-chips. We argued recently that system evolvability, defined as the design characteristic that facilitates more manageable transitions between system generations via the modification of an inherited design, can help remedy these limitations. In this paper, we discuss how platform-based design can constitute a formal entry point to the design and implementation of evolvable smart device/lab-on-chip systems. We present both a hardware/software design framework and the implementation details of a platform prototype enabling at this stage the interfacing of several lab-on-chip variants relying on current- or impedance-based biosensors. Our findings suggest that several change-enabling mechanisms implemented in the higher abstraction software layers of the system can promote evolvability, together with the design of change-absorbing hardware/software interfaces. Our platform architecture is based on a mobile software application programming interface coupled to a modular hardware accessory. It allows the specification of lab-on-chip operation and post-analytic functions at the mobile software layer. We demonstrate its potential by operating a simple lab-on-chip to carry out the detection of dopamine using various electroanalytical methods.
Collapse
|
83
|
Samiei E, Tabrizian M, Hoorfar M. A review of digital microfluidics as portable platforms for lab-on a-chip applications. LAB ON A CHIP 2016; 16:2376-96. [PMID: 27272540 DOI: 10.1039/c6lc00387g] [Citation(s) in RCA: 195] [Impact Index Per Article: 24.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Following the development of microfluidic systems, there has been a high tendency towards developing lab-on-a-chip devices for biochemical applications. A great deal of effort has been devoted to improve and advance these devices with the goal of performing complete sets of biochemical assays on the device and possibly developing portable platforms for point of care applications. Among the different microfluidic systems used for such a purpose, digital microfluidics (DMF) shows high flexibility and capability of performing multiplex and parallel biochemical operations, and hence, has been considered as a suitable candidate for lab-on-a-chip applications. In this review, we discuss the most recent advances in the DMF platforms, and evaluate the feasibility of developing multifunctional packages for performing complete sets of processes of biochemical assays, particularly for point-of-care applications. The progress in the development of DMF systems is reviewed from eight different aspects, including device fabrication, basic fluidic operations, automation, manipulation of biological samples, advanced operations, detection, biological applications, and finally, packaging and portability of the DMF devices. Success in developing the lab-on-a-chip DMF devices will be concluded based on the advances achieved in each of these aspects.
Collapse
Affiliation(s)
- Ehsan Samiei
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V 1V7, Canada.
| | | | | |
Collapse
|
84
|
Gach PC, Shih SC, Sustarich J, Keasling JD, Hillson NJ, Adams PD, Singh AK. A Droplet Microfluidic Platform for Automating Genetic Engineering. ACS Synth Biol 2016; 5:426-33. [PMID: 26830031 DOI: 10.1021/acssynbio.6b00011] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
We present a water-in-oil droplet microfluidic platform for transformation, culture and expression of recombinant proteins in multiple host organisms including bacteria, yeast and fungi. The platform consists of a hybrid digital microfluidic/channel-based droplet chip with integrated temperature control to allow complete automation and integration of plasmid addition, heat-shock transformation, addition of selection medium, culture, and protein expression. The microfluidic format permitted significant reduction in consumption (100-fold) of expensive reagents such as DNA and enzymes compared to the benchtop method. The chip contains a channel to continuously replenish oil to the culture chamber to provide a fresh supply of oxygen to the cells for long-term (∼5 days) cell culture. The flow channel also replenished oil lost to evaporation and increased the number of droplets that could be processed and cultured. The platform was validated by transforming several plasmids into Escherichia coli including plasmids containing genes for fluorescent proteins GFP, BFP and RFP; plasmids with selectable markers for ampicillin or kanamycin resistance; and a Golden Gate DNA assembly reaction. We also demonstrate the applicability of this platform for transformation in widely used eukaryotic organisms such as Saccharomyces cerevisiae and Aspergillus niger. Duration and temperatures of the microfluidic heat-shock procedures were optimized to yield transformation efficiencies comparable to those obtained by benchtop methods with a throughput up to 6 droplets/min. The proposed platform offers potential for automation of molecular biology experiments significantly reducing cost, time and variability while improving throughput.
Collapse
Affiliation(s)
- Philip C. Gach
- Technology
Division, Joint BioEnergy Institute (JBEI), Emeryville, California 94608, United States
- Applied
Biosciences and Engineering, Sandia National Laboratories, Livermore, California 94550, United States
| | - Steve C.C. Shih
- Technology
Division, Joint BioEnergy Institute (JBEI), Emeryville, California 94608, United States
- Applied
Biosciences and Engineering, Sandia National Laboratories, Livermore, California 94550, United States
| | - Jess Sustarich
- Technology
Division, Joint BioEnergy Institute (JBEI), Emeryville, California 94608, United States
- Applied
Biosciences and Engineering, Sandia National Laboratories, Livermore, California 94550, United States
| | - Jay D. Keasling
- Fuels
Synthesis Division, Joint BioEnergy Institute (JBEI), Emeryville, California 94608, United States
- Biological
Systems and Engineering Division, Lawrence Berkeley National Lab, Berkeley, California 94720, United States
- Department
of Bioengineering, University of California, Berkeley, California 94720, United States
- Department of Chemical & Biomolecular Engineering, University of California, Berkeley, California 94720, United States
| | - Nathan J. Hillson
- Technology
Division, Joint BioEnergy Institute (JBEI), Emeryville, California 94608, United States
- Fuels
Synthesis Division, Joint BioEnergy Institute (JBEI), Emeryville, California 94608, United States
- Biological
Systems and Engineering Division, Lawrence Berkeley National Lab, Berkeley, California 94720, United States
- DOE Joint Genome Institute, Walnut
Creek, California 94598, United States
| | - Paul D. Adams
- Technology
Division, Joint BioEnergy Institute (JBEI), Emeryville, California 94608, United States
- Department
of Bioengineering, University of California, Berkeley, California 94720, United States
- Molecular
Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Lab, Berkeley, California 94720, United States
| | - Anup K. Singh
- Technology
Division, Joint BioEnergy Institute (JBEI), Emeryville, California 94608, United States
- Applied
Biosciences and Engineering, Sandia National Laboratories, Livermore, California 94550, United States
| |
Collapse
|
85
|
Hibara A, Fukuyama M, Chung M, Priest C, Proskurnin MA. Interfacial Phenomena and Fluid Control in Micro/Nanofluidics. ANAL SCI 2016; 32:11-21. [PMID: 26753700 DOI: 10.2116/analsci.32.11] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Fundamental aspects of rapidly advancing micro/nanofluidic devices are reviewed from the perspective of liquid interface chemistry and physics, including the influence of capillary pressure in microfluidic two-phase flows and phase transitions related to capillary condensation.
Collapse
Affiliation(s)
- Akihide Hibara
- Department of Chemistry, Graduate School of Science and Engineering, Tokyo Institute of Technology
| | | | | | | | | |
Collapse
|
86
|
Wagner M, Tonoli D, Varesio E, Hopfgartner G. The use of mass spectrometry to analyze dried blood spots. MASS SPECTROMETRY REVIEWS 2016; 35:361-438. [PMID: 25252132 DOI: 10.1002/mas.21441] [Citation(s) in RCA: 156] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to sample preparation and will consider off-line and on-line extractions; in particular, instrumental designs that have been developed so far for DBS extraction will be detailed. Flow injection analysis and applications will be discussed in section IV. The application of surface analysis mass spectrometry (DESI, paper spray, DART, APTDCI, MALDI, LDTD-APCI, and ICP) to DBS is described in section V, while applications based on separation techniques (e.g., liquid or gas chromatography) are presented in section VI. To conclude this review, the current status of DBS analysis is summarized, and future perspectives are provided.
Collapse
Affiliation(s)
- Michel Wagner
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - David Tonoli
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - Emmanuel Varesio
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| | - Gérard Hopfgartner
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211, Geneva, Switzerland
| |
Collapse
|
87
|
Bender BF, Aijian AP, Garrell RL. Digital microfluidics for spheroid-based invasion assays. LAB ON A CHIP 2016; 16:1505-1513. [PMID: 27020962 DOI: 10.1039/c5lc01569c] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Cell invasion is a key process in tissue growth, wound healing, and tumor progression. Most invasion assays examine cells cultured in adherent monolayers, which fail to recapitulate the three-dimensional nuances of the tissue microenvironment. Multicellular cell spheroids have a three-dimensional (3D) morphology and mimic the intercellular interactions found in tissues in vivo, thus providing a more physiologically relevant model for studying the tissue microenvironment and processes such as cell invasion. Spheroid-based invasion assays often require tedious, manually intensive handling protocols or the use of robotic liquid handling systems, which can be expensive to acquire, operate, and maintain. Here we describe a digital microfluidic (DμF) platform that enables formation of spheroids by the hanging drop method, encapsulation of the spheroids in collagen, and the exposure of spheroids to migration-modulating agents. Collagen sol-gel solutions up to 4 mg mL(-1), which form gels with elastic moduli up to ∼50 kPa, can be manipulated on the device. In situ spheroid migration assays show that cells from human fibroblast spheroids exhibit invasion into collagen gels, which can be either enhanced or inhibited by the delivery of exogenous migration modulating agents. Exposing fibroblast spheroids to spheroid secretions from colon cancer spheroids resulted in a >100% increase in fibroblast invasion into the collagen gel, consistent with the cancer-associated fibroblast phenotype. These data show that DμF can be used to automate the liquid handling protocols for spheroid-based invasion assays and create a cell invasion model that mimics the tissue microenvironment more closely than two-dimensional culturing techniques do. A DμF platform that facilitates the creation and assaying of 3D in vitro tissue models has the potential to make automated 3D cell-based assays more accessible to researchers in the life sciences.
Collapse
Affiliation(s)
- Brian F Bender
- Bioengineering Department, University of California, Los Angeles, CA 90095-1600, USA.
| | - Andrew P Aijian
- Bioengineering Department, University of California, Los Angeles, CA 90095-1600, USA.
| | - Robin L Garrell
- Bioengineering Department, University of California, Los Angeles, CA 90095-1600, USA. and Department of Chemistry and Biochemistry, University of California, Los Angeles, CA 90095-1569, USA and California NanoSystems Institute, UCLA Box 722710, Los Angeles, CA, USA 90095
| |
Collapse
|
88
|
Kong T, Brien R, Njus Z, Kalwa U, Pandey S. Motorized actuation system to perform droplet operations on printed plastic sheets. LAB ON A CHIP 2016; 16:1861-72. [PMID: 27080172 DOI: 10.1039/c6lc00176a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
We developed an open microfluidic system to dispense and manipulate discrete droplets on planar plastic sheets. Here, a superhydrophobic material is spray-coated on commercially-available plastic sheets followed by the printing of hydrophilic symbols using an inkjet printer. The patterned plastic sheets are taped to a two-axis tilting platform, powered by stepper motors, that provides mechanical agitation for droplet transport. We demonstrate the following droplet operations: transport of droplets of different sizes, parallel transport of multiple droplets, merging and mixing of multiple droplets, dispensing of smaller droplets from a large droplet or a fluid reservoir, and one-directional transport of droplets. As a proof-of-concept, a colorimetric assay is implemented to measure the glucose concentration in sheep serum. Compared to silicon-based digital microfluidic devices, we believe that the presented system is appealing for various biological experiments because of the ease of altering design layouts of hydrophilic symbols, relatively faster turnaround time in printing plastic sheets, larger area to accommodate more tests, and lower operational costs by using off-the-shelf products.
Collapse
Affiliation(s)
- Taejoon Kong
- Department of Electrical and Computer Engineering, Iowa State University, 1050 Coover Hall, Ames, IA 50011, USA.
| | | | | | | | | |
Collapse
|
89
|
Choi K, Boyacı E, Kim J, Seale B, Barrera-Arbelaez L, Pawliszyn J, Wheeler AR. A digital microfluidic interface between solid-phase microextraction and liquid chromatography-mass spectrometry. J Chromatogr A 2016; 1444:1-7. [PMID: 27048987 DOI: 10.1016/j.chroma.2016.03.029] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 03/10/2016] [Accepted: 03/11/2016] [Indexed: 11/28/2022]
Abstract
We introduce a method to couple solid-phase microextraction (SPME) with HPLC-MS using digital microfluidics (DMF). In the new system, SPME fibers are used to extract analytes from complex sample solutions, after which the analytes are desorbed into solvent droplets in a DMF device. The open geometry of DMF allows straightforward insertion of SPME fibers without requiring a complicated interface, and automated droplet manipulation enables multiplexed processing of the fibers. In contrast to other multiplexed SPME elution interfaces, the low volumes inherent to DMF allow for pre-concentration of analytes prior to analysis. The new SPME-DMF-HPLC-MS method was applied to the quantification of pg/mL-level free steroid hormones in urine. We propose that this new method will be useful for a wide range of applications requiring cleanup and pre-concentration with convenient coupling to high-performance analytical techniques.
Collapse
Affiliation(s)
- Kihwan Choi
- Department of Chemistry, University of Toronto, 80 St George St., Toronto, ON M5S 3H6, Canada; Donnelly Centre for Cellular and Biomolecular Research, 160 College St., Toronto, ON M5S 3E1, Canada; Division of Metrology for Quality of Life, Korea Research Institute of Standards and Science, Yuseong-gu, Daejeon 34113, Republic of Korea
| | - Ezel Boyacı
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Jihye Kim
- Department of Chemistry, University of Toronto, 80 St George St., Toronto, ON M5S 3H6, Canada
| | - Brendon Seale
- Department of Chemistry, University of Toronto, 80 St George St., Toronto, ON M5S 3H6, Canada
| | - Luis Barrera-Arbelaez
- Department of Chemistry, University of Toronto, 80 St George St., Toronto, ON M5S 3H6, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Aaron R Wheeler
- Department of Chemistry, University of Toronto, 80 St George St., Toronto, ON M5S 3H6, Canada; Donnelly Centre for Cellular and Biomolecular Research, 160 College St., Toronto, ON M5S 3E1, Canada; Institute of Biomaterials and Biomedical Engineering, University of Toronto, 164 College St., Toronto, ON M5S 3G9, Canada.
| |
Collapse
|
90
|
Fan SK, Lee HP, Chien CC, Lu YW, Chiu Y, Lin FY. Reconfigurable liquid-core/liquid-cladding optical waveguides with dielectrophoresis-driven virtual microchannels on an electromicrofluidic platform. LAB ON A CHIP 2016; 16:847-854. [PMID: 26841828 DOI: 10.1039/c5lc01233c] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
An electrically reconfigurable liquid-core/liquid-cladding (L(2)) optical waveguide with core liquid γ-butyrolactone (GBL, ncore = 1.4341, εcore = 39) and silicone oil (ncladding = 1.401, εcladding = 2.5) as cladding liquid is accomplished using dielectrophoresis (DEP) that attracts and deforms the core liquid with the greater permittivity to occupy the region of strong electric field provided by Teflon-coated ITO electrodes between parallel glass plates. Instead of continuously flowing core and cladding liquids along a physical microchannel, the DEP-formed L(2) optical waveguide guides light in a stationary virtual microchannel that requires liquids of limited volume without constant supply and creates stable liquid/liquid interfaces for efficient light guidance in a simply fabricated microfluidic device. We designed and examined (1) stationary and (2) moving L(2) optical waveguides on the parallel-plate electromicrofluidic platform. In the stationary L-shaped waveguide, light was guided in a GBL virtual microchannel core for a total of 27.85 mm via a 90° bend (radius 5 mm) before exiting from the light outlet of cross-sectional area 100 μm × 100 μm. For the stationary spiral waveguide, light was guided in a GBL core containing Rhodamine 6G (R6G, 1 mM) and through a series of 90° bends with decreasing radii from 5 mm to 2.5 mm. With the stationary straight waveguide, the propagation loss was measured to be 2.09 dB cm(-1) in GBL with R6G (0.01 mM). The moving L-shaped waveguide was implemented on a versatile electromicrofluidic platform on which electrowetting and DEP were employed to generate a precise GBL droplet and form a waveguide core. On sequentially applying appropriate voltage to one of three parallel L-shaped driving electrodes, the GBL waveguide core was shifted; the guided light was switched at a speed of up to 0.929 mm s(-1) (switching period 70 ms, switching rate 14.3 Hz) when an adequate electric signal (173.1 VRMS, 100 kHz) was applied.
Collapse
Affiliation(s)
- Shih-Kang Fan
- Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan.
| | - Hsuan-Ping Lee
- Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan.
| | - Chia-Chi Chien
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, Taiwan
| | - Yi-Wen Lu
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, Taiwan
| | - Yi Chiu
- Department of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu, Taiwan
| | - Fan-Yi Lin
- Institute of Photonics Technologies, Department of Electrical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| |
Collapse
|
91
|
Ding Y, Qiu F, Casadevall I Solvas X, Chiu FWY, Nelson BJ, deMello A. Microfluidic-Based Droplet and Cell Manipulations Using Artificial Bacterial Flagella. MICROMACHINES 2016; 7:E25. [PMID: 30407399 PMCID: PMC6190376 DOI: 10.3390/mi7020025] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 02/02/2016] [Accepted: 02/03/2016] [Indexed: 01/09/2023]
Abstract
Herein, we assess the functionality of magnetic helical microswimmers as basic tools for the manipulation of soft materials, including microdroplets and single cells. Their ability to perform a range of unit operations is evaluated and the operational challenges associated with their use are established. In addition, we also report on interactions observed between the head of such helical swimmers and the boundaries of droplets and cells and discuss the possibilities of assembling an artificial swimming microorganism or a motorized cell.
Collapse
Affiliation(s)
- Yun Ding
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland.
| | - Famin Qiu
- Institute for Robotics and Intelligent Systems, ETH Zürich, Tannenstrasse 3, 8092 Zürich, Switzerland.
| | - Xavier Casadevall I Solvas
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland.
| | - Flora Wing Yin Chiu
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland.
| | - Bradley J Nelson
- Institute for Robotics and Intelligent Systems, ETH Zürich, Tannenstrasse 3, 8092 Zürich, Switzerland.
| | - Andrew deMello
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland.
| |
Collapse
|
92
|
Tang M, Wang G, Kong SK, Ho HP. A Review of Biomedical Centrifugal Microfluidic Platforms. MICROMACHINES 2016; 7:E26. [PMID: 30407398 PMCID: PMC6190084 DOI: 10.3390/mi7020026] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2015] [Accepted: 02/03/2016] [Indexed: 12/14/2022]
Abstract
Centrifugal microfluidic or lab-on-a-disc platforms have many advantages over other microfluidic systems. These advantages include a minimal amount of instrumentation, the efficient removal of any disturbing bubbles or residual volumes, and inherently available density-based sample transportation and separation. Centrifugal microfluidic devices applied to biomedical analysis and point-of-care diagnostics have been extensively promoted recently. This paper presents an up-to-date overview of these devices. The development of biomedical centrifugal microfluidic platforms essentially covers two categories: (i) unit operations that perform specific functionalities, and (ii) systems that aim to address certain biomedical applications. With the aim to provide a comprehensive representation of current development in this field, this review summarizes progress in both categories. The advanced unit operations implemented for biological processing include mixing, valving, switching, metering and sequential loading. Depending on the type of sample to be used in the system, biomedical applications are classified into four groups: nucleic acid analysis, blood analysis, immunoassays, and other biomedical applications. Our overview of advanced unit operations also includes the basic concepts and mechanisms involved in centrifugal microfluidics, while on the other hand an outline on reported applications clarifies how an assembly of unit operations enables efficient implementation of various types of complex assays. Lastly, challenges and potential for future development of biomedical centrifugal microfluidic devices are discussed.
Collapse
Affiliation(s)
- Minghui Tang
- Department of Electronic Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong, China.
| | - Guanghui Wang
- Institute of Optical Communication Engineering, Nanjing University, Jiangsu 210009, China.
| | - Siu-Kai Kong
- School of Life Sciences, The Chinese University of Hong Kong, Shatin, Hong Kong, China.
| | - Ho-Pui Ho
- Department of Electronic Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong, China.
| |
Collapse
|
93
|
Huang CY, Tsai PY, Lee IC, Hsu HY, Huang HY, Fan SK, Yao DJ, Liu CH, Hsu W. A highly efficient bead extraction technique with low bead number for digital microfluidic immunoassay. BIOMICROFLUIDICS 2016; 10:011901. [PMID: 26858807 PMCID: PMC4714987 DOI: 10.1063/1.4939942] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Accepted: 12/07/2015] [Indexed: 05/04/2023]
Abstract
Here, we describe a technique to manipulate a low number of beads to achieve high washing efficiency with zero bead loss in the washing process of a digital microfluidic (DMF) immunoassay. Previously, two magnetic bead extraction methods were reported in the DMF platform: (1) single-side electrowetting method and (2) double-side electrowetting method. The first approach could provide high washing efficiency, but it required a large number of beads. The second approach could reduce the required number of beads, but it was inefficient where multiple washes were required. More importantly, bead loss during the washing process was unavoidable in both methods. Here, an improved double-side electrowetting method is proposed for bead extraction by utilizing a series of unequal electrodes. It is shown that, with proper electrode size ratio, only one wash step is required to achieve 98% washing rate without any bead loss at bead number less than 100 in a droplet. It allows using only about 25 magnetic beads in DMF immunoassay to increase the number of captured analytes on each bead effectively. In our human soluble tumor necrosis factor receptor I (sTNF-RI) model immunoassay, the experimental results show that, comparing to our previous results without using the proposed bead extraction technique, the immunoassay with low bead number significantly enhances the fluorescence signal to provide a better limit of detection (3.14 pg/ml) with smaller reagent volumes (200 nl) and shorter analysis time (<1 h). This improved bead extraction technique not only can be used in the DMF immunoassay but also has great potential to be used in any other bead-based DMF systems for different applications.
Collapse
Affiliation(s)
- Cheng-Yeh Huang
- Department of Mechanical Engineering, National Chiao Tung University , Hsinchu, Taiwan
| | - Po-Yen Tsai
- Department of Mechanical Engineering, National Chiao Tung University , Hsinchu, Taiwan
| | - I-Chin Lee
- Department of Applied Chemistry, National Chiao Tung University , Hsinchu, Taiwan
| | - Hsin-Yun Hsu
- Department of Applied Chemistry, National Chiao Tung University , Hsinchu, Taiwan
| | | | - Shih-Kang Fan
- Department of Mechanical Engineering, National Taiwan University , Taipei, Taiwan
| | | | - Cheng-Hsien Liu
- Department of Power Mechanical Engineering, National Tsing Hua University , Hsinchu, Taiwan
| | - Wensyang Hsu
- Department of Mechanical Engineering, National Chiao Tung University , Hsinchu, Taiwan
| |
Collapse
|
94
|
|
95
|
Baratian D, Cavalli A, van den Ende D, Mugele F. On the shape of a droplet in a wedge: new insight from electrowetting. SOFT MATTER 2015; 11:7717-7721. [PMID: 26186493 DOI: 10.1039/c5sm01511a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The equilibrium morphology of liquid drops exposed to geometric constraints can be rather complex. Even for simple geometries, analytical solutions are scarce. Here, we investigate the equilibrium shape and position of liquid drops confined in the wedge between two solid surfaces at an angle α. Using electrowetting, we control the contact angle and thereby manipulate the shape and the equilibrium position of aqueous drops in ambient oil. In the absence of contact angle hysteresis and buoyancy, we find that the equilibrium shape is given by a truncated sphere, at a position that is determined by the drop volume and the contact angle. At this position, the net normal force between drop and the surfaces vanishes. The effect of buoyancy gives rise to substantial deviations from this equilibrium configuration which we discuss here as well. We eventually show how the geometric constraint and electrowetting can be used to position droplets inside a wedge in a controlled way, without mechanical actuation.
Collapse
Affiliation(s)
- D Baratian
- Physics of Complex Fluids, MESA+ Institute for Nanotechnology, Department of Science & Technology, University of Twente, The Netherlands.
| | | | | | | |
Collapse
|
96
|
Ultra-Portable Smartphone Controlled Integrated Digital Microfluidic System in a 3D-Printed Modular Assembly. MICROMACHINES 2015. [DOI: 10.3390/mi6091289] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
97
|
Abstract
Fast and reliable diagnoses are invaluable in clinical care. Samples (e.g., blood, urine, and saliva) are collected and analyzed for various biomarkers to quickly and sensitively assess disease progression, monitor response to treatment, and determine a patient's prognosis. Processing conventional samples entails many manual time-consuming steps. Consequently, clinical specimens must be processed by skilled technicians before antigens or nucleic acids are detected, and these are often present at dilute concentrations. Recently, several automated microchip technologies have been developed that potentially offer many advantages over traditional bench-top extraction methods. The smaller length scales and more refined transport mechanisms that characterize these microfluidic devices enable faster and more efficient biomarker enrichment and extraction. Additionally, they can be designed to perform multiple tests or experimental steps on one integrated, automated platform. This review explores the current research on microfluidic methods of sample preparation that are designed to aid diagnosis, and covers a broad spectrum of extraction techniques and designs for various types of samples and analytes.
Collapse
Affiliation(s)
- Francis Cui
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912;
| | - Minsoung Rhee
- Sandia National Laboratories, Livermore, California 94551-0969
| | - Anup Singh
- Sandia National Laboratories, Livermore, California 94551-0969
| | - Anubhav Tripathi
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, Rhode Island 02912;
| |
Collapse
|
98
|
Im DJ, Jeong SN, Yoo BS, Kim B, Kim DP, Jeong WJ, Kang IS. Digital Microfluidic Approach for Efficient Electroporation with High Productivity: Transgene Expression of Microalgae without Cell Wall Removal. Anal Chem 2015; 87:6592-9. [DOI: 10.1021/acs.analchem.5b00725] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Do Jin Im
- Department
of Chemical Engineering, Pukyong National University, 365 Sinseon-ro, Nam-gu, Busan 608-739, South Korea
| | | | | | | | | | - Won-Joong Jeong
- Sustainable Bioresource
Research Center, Korea Research Institute of Bioscience and Biotechnology
(KRIBB), 125 Gawhak-ro, Yuseong-gu, DaeJeon 305-806, South Korea
| | | |
Collapse
|
99
|
Kinetic studies of microfabricated biosensors using local adsorption strategy. Biosens Bioelectron 2015; 74:8-15. [PMID: 26093123 DOI: 10.1016/j.bios.2015.05.061] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2015] [Revised: 05/22/2015] [Accepted: 05/26/2015] [Indexed: 11/23/2022]
Abstract
Micro/nano scale biosensors integrated with the local adsorption mask have been demonstrated to have a better limit of detection (LOD) and less sample consumptions. However, the molecular diffusions and binding kinetics in such confined droplet have been less studied which limited further development and application of the local adsorption method and imposed restrictions on discovery of new signal amplification strategies. In this work, we studied the kinetic issues via experimental investigations and theoretical analysis on microfabricated biosensors. Mass sensitive film bulk acoustic resonator (FBAR) sensors with hydrophobic Teflon film covering the non-sensing area as the mask were introduced. The fabricated masking sensors were characterized with physical adsorption of bovine serum albumin (BSA) and specific binding of antibody and antigen. Over an order of magnitude improvement on LOD was experimentally monitored. An analytical model was introduced to discuss the target molecule diffusion and binding kinetics in droplet environment, especially the crucial effects of incubation time, which has been less covered in previous local adsorption related literatures. An incubation time accumulated signal amplification effect was theoretically predicted, experimentally monitored and carefully explained. In addition, device optimization was explored based on the analytical model to fully utilize the merits of local adsorption. The discussions on the kinetic issues are believed to have wide implications for other types of micro/nano fabricated biosensors with potentially improved LOD.
Collapse
|
100
|
Rackus DG, Shamsi MH, Wheeler AR. Electrochemistry, biosensors and microfluidics: a convergence of fields. Chem Soc Rev 2015; 44:5320-40. [PMID: 25962356 DOI: 10.1039/c4cs00369a] [Citation(s) in RCA: 236] [Impact Index Per Article: 26.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Electrochemistry, biosensors and microfluidics are popular research topics that have attracted widespread attention from chemists, biologists, physicists, and engineers. Here, we introduce the basic concepts and recent histories of electrochemistry, biosensors, and microfluidics, and describe how they are combining to form new application-areas, including so-called "point-of-care" systems in which measurements traditionally performed in a laboratory are moved into the field. We propose that this review can serve both as a useful starting-point for researchers who are new to these topics, as well as being a compendium of the current state-of-the art for experts in these evolving areas.
Collapse
Affiliation(s)
- Darius G Rackus
- Department of Chemistry, University of Toronto, 80 St. George St., Toronto, ON M5S 3H6, Canada.
| | | | | |
Collapse
|