51
|
Marx L, Gsell MAF, Rund A, Caforio F, Prassl AJ, Toth-Gayor G, Kuehne T, Augustin CM, Plank G. Personalization of electro-mechanical models of the pressure-overloaded left ventricle: fitting of Windkessel-type afterload models. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2020; 378:20190342. [PMID: 32448067 PMCID: PMC7287328 DOI: 10.1098/rsta.2019.0342] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 04/01/2020] [Indexed: 05/21/2023]
Abstract
Computer models of left ventricular (LV) electro-mechanics (EM) show promise as a tool for assessing the impact of increased afterload upon LV performance. However, the identification of unique afterload model parameters and the personalization of EM LV models remains challenging due to significant clinical input uncertainties. Here, we personalized a virtual cohort of N = 17 EM LV models under pressure overload conditions. A global-local optimizer was developed to uniquely identify parameters of a three-element Windkessel (Wk3) afterload model. The sensitivity of Wk3 parameters to input uncertainty and of the EM LV model to Wk3 parameter uncertainty was analysed. The optimizer uniquely identified Wk3 parameters, and outputs of the personalized EM LV models showed close agreement with clinical data in all cases. Sensitivity analysis revealed a strong dependence of Wk3 parameters on input uncertainty. However, this had limited impact on outputs of EM LV models. A unique identification of Wk3 parameters from clinical data appears feasible, but it is sensitive to input uncertainty, thus depending on accurate invasive measurements. By contrast, the EM LV model outputs were less sensitive, with errors of less than 8.14% for input data errors of 10%, which is within the bounds of clinical data uncertainty. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'.
Collapse
Affiliation(s)
- Laura Marx
- Gottfried Schatz Research Center for Cell Signaling, Metabolism and Aging - Division of Biophysics, Medical University Graz, Graz, Austria
| | - Matthias A. F. Gsell
- Gottfried Schatz Research Center for Cell Signaling, Metabolism and Aging - Division of Biophysics, Medical University Graz, Graz, Austria
| | - Armin Rund
- Institute for Mathematics and Scientific Computing, University of Graz, Graz, Austria
| | - Federica Caforio
- Gottfried Schatz Research Center for Cell Signaling, Metabolism and Aging - Division of Biophysics, Medical University Graz, Graz, Austria
| | - Anton J. Prassl
- Gottfried Schatz Research Center for Cell Signaling, Metabolism and Aging - Division of Biophysics, Medical University Graz, Graz, Austria
| | - Gabor Toth-Gayor
- Department of Cardiology, Medical University Graz, Graz, Austria
| | - Titus Kuehne
- Institute for Cardiovascular Computer-assisted Medicine (ICM), Charité - Universitätsmedizin Berlin, Berlin, Germany
- Department of Imaging and Congenital Heart Disease, German Heart Center Berlin, Berlin, Germany
| | - Christoph M. Augustin
- Gottfried Schatz Research Center for Cell Signaling, Metabolism and Aging - Division of Biophysics, Medical University Graz, Graz, Austria
| | - Gernot Plank
- Gottfried Schatz Research Center for Cell Signaling, Metabolism and Aging - Division of Biophysics, Medical University Graz, Graz, Austria
- e-mail:
| |
Collapse
|
52
|
Lei CL, Ghosh S, Whittaker DG, Aboelkassem Y, Beattie KA, Cantwell CD, Delhaas T, Houston C, Novaes GM, Panfilov AV, Pathmanathan P, Riabiz M, dos Santos RW, Walmsley J, Worden K, Mirams GR, Wilkinson RD. Considering discrepancy when calibrating a mechanistic electrophysiology model. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2020; 378:20190349. [PMID: 32448065 PMCID: PMC7287333 DOI: 10.1098/rsta.2019.0349] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 04/21/2020] [Indexed: 05/21/2023]
Abstract
Uncertainty quantification (UQ) is a vital step in using mathematical models and simulations to take decisions. The field of cardiac simulation has begun to explore and adopt UQ methods to characterize uncertainty in model inputs and how that propagates through to outputs or predictions; examples of this can be seen in the papers of this issue. In this review and perspective piece, we draw attention to an important and under-addressed source of uncertainty in our predictions-that of uncertainty in the model structure or the equations themselves. The difference between imperfect models and reality is termed model discrepancy, and we are often uncertain as to the size and consequences of this discrepancy. Here, we provide two examples of the consequences of discrepancy when calibrating models at the ion channel and action potential scales. Furthermore, we attempt to account for this discrepancy when calibrating and validating an ion channel model using different methods, based on modelling the discrepancy using Gaussian processes and autoregressive-moving-average models, then highlight the advantages and shortcomings of each approach. Finally, suggestions and lines of enquiry for future work are provided. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'.
Collapse
Affiliation(s)
- Chon Lok Lei
- Computational Biology and Health Informatics, Department of Computer Science, University of Oxford, Oxford, UK
| | - Sanmitra Ghosh
- MRC Biostatistics Unit, University of Cambridge, Cambridge, UK
| | - Dominic G. Whittaker
- Centre for Mathematical Medicine and Biology, School of Mathematical Sciences, University of Nottingham, Nottingham, UK
| | - Yasser Aboelkassem
- Department of Bioengineering, University of California San Diego, La Jolla, CA, USA
| | - Kylie A. Beattie
- Systems Modeling and Translational Biology, GlaxoSmithKline R&D, Stevenage, UK
| | - Chris D. Cantwell
- ElectroCardioMaths Programme, Centre for Cardiac Engineering, Imperial College London, London, UK
| | - Tammo Delhaas
- CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Charles Houston
- ElectroCardioMaths Programme, Centre for Cardiac Engineering, Imperial College London, London, UK
| | - Gustavo Montes Novaes
- Graduate Program in Computational Modeling, Universidade Federal de Juiz de Fora, Juiz de Fora, Brazil
| | - Alexander V. Panfilov
- Department of Physics and Astronomy, Ghent University, Ghent, Belgium
- Laboratory of Computational Biology and Medicine, Ural Federal University, Ekaterinburg, Russia
| | - Pras Pathmanathan
- US Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Silver Spring, MD, USA
| | - Marina Riabiz
- Department of Biomedical Engineering King’s College London and Alan Turing Institute, London, UK
| | - Rodrigo Weber dos Santos
- Graduate Program in Computational Modeling, Universidade Federal de Juiz de Fora, Juiz de Fora, Brazil
| | - John Walmsley
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA
| | - Keith Worden
- Dynamics Research Group, Department of Mechanical Engineering, University of Sheffield, Sheffield, UK
| | - Gary R. Mirams
- Centre for Mathematical Medicine and Biology, School of Mathematical Sciences, University of Nottingham, Nottingham, UK
| | | |
Collapse
|
53
|
Clayton RH, Aboelkassem Y, Cantwell CD, Corrado C, Delhaas T, Huberts W, Lei CL, Ni H, Panfilov AV, Roney C, dos Santos RW. An audit of uncertainty in multi-scale cardiac electrophysiology models. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2020; 378:20190335. [PMID: 32448070 PMCID: PMC7287340 DOI: 10.1098/rsta.2019.0335] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/16/2020] [Indexed: 05/21/2023]
Abstract
Models of electrical activation and recovery in cardiac cells and tissue have become valuable research tools, and are beginning to be used in safety-critical applications including guidance for clinical procedures and for drug safety assessment. As a consequence, there is an urgent need for a more detailed and quantitative understanding of the ways that uncertainty and variability influence model predictions. In this paper, we review the sources of uncertainty in these models at different spatial scales, discuss how uncertainties are communicated across scales, and begin to assess their relative importance. We conclude by highlighting important challenges that continue to face the cardiac modelling community, identifying open questions, and making recommendations for future studies. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'.
Collapse
Affiliation(s)
- Richard H. Clayton
- Insigneo institute for in-silico Medicine and Department of Computer Science, University of Sheffield, Sheffield, UK
- e-mail:
| | - Yasser Aboelkassem
- Department of Bioengineering, University of California, San Diego, CA, USA
| | | | - Cesare Corrado
- Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, UK
| | - Tammo Delhaas
- School of Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Wouter Huberts
- School of Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Chon Lok Lei
- Computational Biology and Health Informatics, Department of Computer Science, University of Oxford, Oxford, UK
| | - Haibo Ni
- Department of Pharmacology, University of California, Davis, CA, USA
| | - Alexander V. Panfilov
- Department of Physics and Astronomy, University of Gent, Gent, Belgium
- Laboratory of Computational Biology and Medicine, Ural Federal University, Ekaterinburg, Russia
| | - Caroline Roney
- Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, UK
| | | |
Collapse
|
54
|
Niederer SA, Aboelkassem Y, Cantwell CD, Corrado C, Coveney S, Cherry EM, Delhaas T, Fenton FH, Panfilov AV, Pathmanathan P, Plank G, Riabiz M, Roney CH, dos Santos RW, Wang L. Creation and application of virtual patient cohorts of heart models. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2020; 378:20190558. [PMID: 32448064 PMCID: PMC7287335 DOI: 10.1098/rsta.2019.0558] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/06/2020] [Indexed: 05/21/2023]
Abstract
Patient-specific cardiac models are now being used to guide therapies. The increased use of patient-specific cardiac simulations in clinical care will give rise to the development of virtual cohorts of cardiac models. These cohorts will allow cardiac simulations to capture and quantify inter-patient variability. However, the development of virtual cohorts of cardiac models will require the transformation of cardiac modelling from small numbers of bespoke models to robust and rapid workflows that can create large numbers of models. In this review, we describe the state of the art in virtual cohorts of cardiac models, the process of creating virtual cohorts of cardiac models, and how to generate the individual cohort member models, followed by a discussion of the potential and future applications of virtual cohorts of cardiac models. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'.
Collapse
Affiliation(s)
| | | | | | | | | | - E. M. Cherry
- Georgia Institute of Technology, Atlanta, GA, USA
| | - T. Delhaas
- Maastricht University, Maastricht, the Netherlands
| | - F. H. Fenton
- Georgia Institute of Technology, Atlanta, GA, USA
| | - A. V. Panfilov
- Ghent University, Gent, Belgium
- Laboratory of Computational Biology and Medicine, Ural Federal University, Ekaterinburg, Russia
| | - P. Pathmanathan
- Center for Devices and Radiological Health, U.S. Food and Administration, Rockville, MD, USA
| | - G. Plank
- Medical University of Graz, Graz, Austria
| | | | | | | | - L. Wang
- Rochester Institute of Technology, La JollaRochester, NY, USA
| |
Collapse
|
55
|
Augustin CM, Fastl TE, Neic A, Bellini C, Whitaker J, Rajani R, O'Neill MD, Bishop MJ, Plank G, Niederer SA. The impact of wall thickness and curvature on wall stress in patient-specific electromechanical models of the left atrium. Biomech Model Mechanobiol 2020; 19:1015-1034. [PMID: 31802292 PMCID: PMC7203597 DOI: 10.1007/s10237-019-01268-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Accepted: 11/21/2019] [Indexed: 12/31/2022]
Abstract
The left atrium (LA) has a complex anatomy with heterogeneous wall thickness and curvature. The anatomy plays an important role in determining local wall stress; however, the relative contribution of wall thickness and curvature in determining wall stress in the LA is unknown. We have developed electromechanical finite element (FE) models of the LA using patient-specific anatomical FE meshes with rule-based myofiber directions. The models of the LA were passively inflated to 10mmHg followed by simulation of the contraction phase of the atrial cardiac cycle. The FE models predicted maximum LA volumes of 156.5 mL, 99.3 mL and 83.4 mL and ejection fractions of 36.9%, 32.0% and 25.2%. The median wall thickness in the 3 cases was calculated as [Formula: see text] mm, [Formula: see text] mm, and [Formula: see text] mm. The median curvature was determined as [Formula: see text] [Formula: see text], [Formula: see text], and [Formula: see text]. Following passive inflation, the correlation of wall stress with the inverse of wall thickness and curvature was 0.55-0.62 and 0.20-0.25, respectively. At peak contraction, the correlation of wall stress with the inverse of wall thickness and curvature was 0.38-0.44 and 0.16-0.34, respectively. In the LA, the 1st principal Cauchy stress is more dependent on wall thickness than curvature during passive inflation and both correlations decrease during active contraction. This emphasizes the importance of including the heterogeneous wall thickness in electromechanical FE simulations of the LA. Overall, simulation results and sensitivity analyses show that in complex atrial anatomy it is unlikely that a simple anatomical-based law can be used to estimate local wall stress, demonstrating the importance of FE analyses.
Collapse
Affiliation(s)
- Christoph M Augustin
- Department of Mechanical Engineering, University of California, Berkeley, Berkeley, USA
- Gottfried Schatz Research Center: Division of Biophysics, Medical University of Graz, Graz, Austria
| | - Thomas E Fastl
- Department of Biomedical Engineering, King's College London, London, UK
| | - Aurel Neic
- Gottfried Schatz Research Center: Division of Biophysics, Medical University of Graz, Graz, Austria
| | - Chiara Bellini
- Department of Bioengineering, Northeastern University, Boston, USA
| | - John Whitaker
- Department of Cardiology, Guy's and St Thomas' Hospitals, London, UK
| | - Ronak Rajani
- Department of Cardiology, Guy's and St Thomas' Hospitals, London, UK
| | - Mark D O'Neill
- Department of Cardiology, Guy's and St Thomas' Hospitals, London, UK
| | - Martin J Bishop
- Department of Biomedical Engineering, King's College London, London, UK
| | - Gernot Plank
- Gottfried Schatz Research Center: Division of Biophysics, Medical University of Graz, Graz, Austria
- BioTechMed-Graz, Graz, Austria
| | - Steven A Niederer
- Department of Biomedical Engineering, King's College London, London, UK.
| |
Collapse
|
56
|
Benson AP, Stevenson-Cocks HJ, Whittaker DG, White E, Colman MA. Multi-scale approaches for the simulation of cardiac electrophysiology: II - Tissue-level structure and function. Methods 2020; 185:60-81. [PMID: 31988002 DOI: 10.1016/j.ymeth.2020.01.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 11/15/2019] [Accepted: 01/14/2020] [Indexed: 02/06/2023] Open
Abstract
Computational models of the heart, from cell-level models, through one-, two- and three-dimensional tissue-level simplifications, to biophysically-detailed three-dimensional models of the ventricles, atria or whole heart, allow the simulation of excitation and propagation of this excitation, and have provided remarkable insight into the normal and pathological functioning of the heart. In this article we present equations for modelling cellular excitation (i.e. the cell action potential) from both a phenomenological and a biophysical perspective. Hodgkin-Huxley formalism is discussed, along with the current generation of biophysically-detailed cardiac cell models. Alternative Markovian formulations for modelling ionic currents are also presented. Equations describing propagation of this cellular excitation, through one-, two- and three-dimensional idealised or realistic tissues, are then presented. For all types of model, from cell to tissue, methods for discretisation and integration of the underlying equations are discussed. The article finishes with a discussion of two tissue-level experimental imaging techniques - diffusion tensor magnetic resonance imaging and optical imaging - that can be used to provide data for parameterisation and validation of cell- and tissue-level cardiac models.
Collapse
Affiliation(s)
- Alan P Benson
- School of Biomedical Sciences University of Leeds, Leeds LS2 9JT, UK.
| | | | - Dominic G Whittaker
- School of Biomedical Sciences University of Leeds, Leeds LS2 9JT, UK; School of Mathematical Sciences, University of Nottingham, Nottingham NG7 2RD, UK
| | - Ed White
- School of Biomedical Sciences University of Leeds, Leeds LS2 9JT, UK
| | - Michael A Colman
- School of Biomedical Sciences University of Leeds, Leeds LS2 9JT, UK
| |
Collapse
|
57
|
Abstract
The treatment of individual patients in cardiology practice increasingly relies on advanced imaging, genetic screening and devices. As the amount of imaging and other diagnostic data increases, paralleled by the greater capacity to personalize treatment, the difficulty of using the full array of measurements of a patient to determine an optimal treatment seems also to be paradoxically increasing. Computational models are progressively addressing this issue by providing a common framework for integrating multiple data sets from individual patients. These models, which are based on physiology and physics rather than on population statistics, enable computational simulations to reveal diagnostic information that would have otherwise remained concealed and to predict treatment outcomes for individual patients. The inherent need for patient-specific models in cardiology is clear and is driving the rapid development of tools and techniques for creating personalized methods to guide pharmaceutical therapy, deployment of devices and surgical interventions.
Collapse
|
58
|
Camara O. Best (and Worst) Practices for Organizing a Challenge on Cardiac Biophysical Models During AI Summer: The CRT-EPiggy19 Challenge. STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART. MULTI-SEQUENCE CMR SEGMENTATION, CRT-EPIGGY AND LV FULL QUANTIFICATION CHALLENGES 2020. [DOI: 10.1007/978-3-030-39074-7_35] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
59
|
Colli-Franzone P, Gionti V, Pavarino L, Scacchi S, Storti C. Role of infarct scar dimensions, border zone repolarization properties and anisotropy in the origin and maintenance of cardiac reentry. Math Biosci 2019; 315:108228. [DOI: 10.1016/j.mbs.2019.108228] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 07/13/2019] [Accepted: 07/14/2019] [Indexed: 10/26/2022]
|
60
|
Computationally guided personalized targeted ablation of persistent atrial fibrillation. Nat Biomed Eng 2019; 3:870-879. [PMID: 31427780 PMCID: PMC6842421 DOI: 10.1038/s41551-019-0437-9] [Citation(s) in RCA: 147] [Impact Index Per Article: 29.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 07/03/2019] [Indexed: 12/12/2022]
Abstract
Atrial fibrillation (AF) — the most common arrhythmia — significantly increases the risk of stroke and heart failure. Although catheter ablation can restore normal heart rhythms, patients with persistent AF who develop atrial fibrosis often undergo multiple failed ablations and thus increased procedural risks. Here, we present personalized computational modelling for the reliable predetermination of ablation targets, which are then used to guide the ablation procedure in patients with persistent AF and atrial fibrosis. We first show that a computational model of the atria of patients identifies fibrotic tissue that if ablated will not sustain AF. We then integrated the target-ablation sites in a clinical-mapping system, and tested its feasibility in 10 patients with persistent AF. The computational prediction of ablation targets avoids lengthy electrical mapping and could improve the accuracy and efficacy of targeted AF ablation in patients whilst eliminating the need for repeat procedures.
Collapse
|
61
|
Sahli Costabal F, Yao J, Sher A, Kuhl E. Predicting critical drug concentrations and torsadogenic risk using a multiscale exposure-response simulator. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2019; 144:61-76. [PMID: 30482568 PMCID: PMC6483901 DOI: 10.1016/j.pbiomolbio.2018.10.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Revised: 09/21/2018] [Accepted: 10/11/2018] [Indexed: 12/12/2022]
Abstract
Torsades de pointes is a serious side effect of many drugs that can trigger sudden cardiac death, even in patients with structurally normal hearts. Torsadogenic risk has traditionally been correlated with the blockage of a specific potassium channel and a prolonged recovery period in the electrocardiogram. However, the precise mechanisms by which single channel block translates into heart rhythm disorders remain incompletely understood. Here we establish a multiscale exposure-response simulator that converts block-concentration characteristics from single cell recordings into three-dimensional excitation profiles and electrocardiograms to rapidly assess torsadogenic risk. For the drug dofetilide, we characterize the QT interval and heart rate at different drug concentrations and identify the critical concentration at the onset of torsades de pointes: For dofetilide concentrations of 2x, 3x, and 4x, as multiples of the free plasma concentration Cmax = 2.1 nM, the QT interval increased by +62.0%, +71.2%, and +82.3% compared to baseline, and the heart rate changed by -21.7%, -23.3%, and +88.3%. The last number indicates that, at the critical concentration of 4x, the heart spontaneously developed an episode of a torsades-like arrhythmia. Strikingly, this critical drug concentration is higher than the concentration estimated from early afterdepolarizations in single cells and lower than in one-dimensional cable models. Our results highlight the importance of whole heart modeling and explain, at least in part, why current regulatory paradigms often fail to accurately quantify the pro-arrhythmic potential of a drug. Our exposure-response simulator could provide a more mechanistic assessment of pro-arrhythmic risk and help establish science-based guidelines to reduce rhythm disorders, design safer drugs, and accelerate drug development.
Collapse
Affiliation(s)
| | - Jiang Yao
- Dassault Systèmes Simulia Corporation, Johnston, RI, 02919, United States
| | - Anna Sher
- Internal Medicine Research Unit, Pfizer Inc, Cambridge, MA, 02139, United States
| | - Ellen Kuhl
- Department of Mechanical Engineering, Stanford University, Stanford, CA, 94305, United States.
| |
Collapse
|
62
|
Pathmanathan P, Cordeiro JM, Gray RA. Comprehensive Uncertainty Quantification and Sensitivity Analysis for Cardiac Action Potential Models. Front Physiol 2019; 10:721. [PMID: 31297060 PMCID: PMC6607060 DOI: 10.3389/fphys.2019.00721] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Accepted: 05/23/2019] [Indexed: 12/15/2022] Open
Abstract
Recent efforts to ensure the reliability of computational model-based predictions in healthcare, such as the ASME V&V40 Standard, emphasize the importance of uncertainty quantification (UQ) and sensitivity analysis (SA) when evaluating computational models. UQ involves empirically determining the uncertainty in model inputs-typically resulting from natural variability or measurement error-and then calculating the resultant uncertainty in model outputs. SA involves calculating how uncertainty in model outputs can be apportioned to input uncertainty. Rigorous comprehensive UQ/SA provides confidence that model-based decisions are robust to underlying uncertainties. However, comprehensive UQ/SA is not currently feasible for whole heart models, due to numerous factors including model complexity and difficulty in measuring variability in the many parameters. Here, we present a significant step to developing a framework to overcome these limitations. We: (i) developed a novel action potential (AP) model of moderate complexity (six currents, seven variables, 36 parameters); (ii) prescribed input variability for all parameters (not empirically derived); (iii) used a single "hyper-parameter" to study increasing levels of parameter uncertainty; (iv) performed UQ and SA for a range of model-derived quantities with physiological relevance; and (v) present quantitative and qualitative ways to analyze different behaviors that occur under parameter uncertainty, including "model failure". This is the first time uncertainty in every parameter (including conductances, steady-state parameters, and time constant parameters) of every ionic current in a cardiac model has been studied. This approach allowed us to demonstrate that, for this model, the simulated AP is fully robust to low levels of parameter uncertainty - to our knowledge the first time this has been shown of any cardiac model. A range of dynamics was observed at larger parameter uncertainty (e.g., oscillatory dynamics); analysis revealed that five parameters were highly influential in these dynamics. Overall, we demonstrate feasibility of performing comprehensive UQ/SA for cardiac cell models and demonstrate how to assess robustness and overcome model failure when performing cardiac UQ analyses. The approach presented here represents an important and significant step toward the development of model-based clinical tools which are demonstrably robust to all underlying uncertainties and therefore more reliable in safety-critical decision-making.
Collapse
Affiliation(s)
- Pras Pathmanathan
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States
| | | | - Richard A. Gray
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States
| |
Collapse
|
63
|
Galappaththige SK, Pathmanathan P, Bishop MJ, Gray RA. Effect of Heart Structure on Ventricular Fibrillation in the Rabbit: A Simulation Study. Front Physiol 2019; 10:564. [PMID: 31164829 PMCID: PMC6536150 DOI: 10.3389/fphys.2019.00564] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Accepted: 04/24/2019] [Indexed: 01/07/2023] Open
Abstract
Ventricular fibrillation (VF) is a lethal condition that affects millions worldwide. The mechanism underlying VF is unstable reentrant electrical waves rotating around lines called filaments. These complex spatio-temporal patterns can be studied using both experimental and numerical methods. Computer simulations provide unique insights including high resolution dynamics throughout the heart and systematic control of quantities such as fiber orientation and cellular kinetics that are not feasible experimentally. Here we study filament dynamics using two bi-ventricular 3-D high-resolution rabbit heart geometries, one with detailed fine structure and another without fine structure. We studied filament dynamics using anisotropic and isotropic conductivities, and with four cellular action potential models with different recovery kinetics. Spiral wave dynamics observed in isotropic two-dimensional sheets were not predictive of the behavior in the whole heart. In 2-D the four cell models exhibited stable reentry, meandering spiral waves, and spiral-wave breakup. In the whole heart with fine structure, all simulation results exhibited complex dynamics reminiscent of fibrillation observed experimentally. In the whole heart without fine structure, anisotropy acted to destabilize filament dynamics although the number of filaments was reduced compared to the heart with structure. In addition, in isotropic hearts without structure the two cell models that exhibited meandering spiral waves in 2-D, stabilized into figure-of-eight surface patterns. We also studied the sensitivity of filament dynamics to computer system configuration and initial conditions. After large simulation times, different macroscopic results sometimes occurred across different system configurations, likely due to a lack of bitwise reproducibility. The study conclusions were insensitive to initial condition perturbations, however, the exact number of filaments over time and their trends were altered by these changes. In summary, we present the following new results. First, we provide a new cell model that resembles the surface patterns of VF in the rabbit heart both qualitatively and quantitatively. Second, filament dynamics in the whole heart cannot be predicted from spiral wave dynamics in 2-D and we identified anisotropy as one destabilizing factor. Third, the exact dynamics of filaments are sensitive to a variety of factors, so we suggest caution in their interpretation and their quantitative analyses.
Collapse
Affiliation(s)
- Suran K Galappaththige
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States
| | - Pras Pathmanathan
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States
| | - Martin J Bishop
- Division of Imaging Sciences, Department of Biomedical Engineering, King's College London, London, United Kingdom
| | - Richard A Gray
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States
| |
Collapse
|
64
|
Costabal FS, Matsuno K, Yao J, Perdikaris P, Kuhl E. Machine learning in drug development: Characterizing the effect of 30 drugs on the QT interval using Gaussian process regression, sensitivity analysis, and uncertainty quantification. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING 2019; 348:313-333. [PMID: 32863454 PMCID: PMC7454226 DOI: 10.1016/j.cma.2019.01.033] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Prolonged QT intervals are a major risk factor for ventricular arrhythmias and a leading cause of sudden cardiac death. Various drugs are known to trigger QT interval prolongation and increase the proarrhythmic potential. Yet, how precisely the action of drugs on the cellular level translates into QT interval prolongation on the whole organ level remains insufficiently understood. Here we use machine learning techniques to systematically characterize the effect of 30 common drugs on the QT interval. We combine information from high fidelity three-dimensional human heart simulations with low fidelity one-dimensional cable simulations to build a surrogate model for the QT interval using multi-fidelity Gaussian process regression. Once trained and cross-validated, we apply our surrogate model to perform sensitivity analysis and uncertainty quantification. Our sensitivity analysis suggests that compounds that block the rapid delayed rectifier potassium current I Kr have the greatest prolonging effect of the QT interval, and that blocking the L-type calcium current I CaL and late sodium current I NaL shortens the QT interval. Our uncertainty quantification allows us to propagate the experimental variability from individual block-concentration measurements into the QT interval and reveals that QT interval uncertainty is mainly driven by the variability in I Kr block. In a final validation study, we demonstrate an excellent agreement between our predicted QT interval changes and the changes observed in a randomized clinical trial for the drugs dofetilide, quinidine, ranolazine, and verapamil. We anticipate that both the machine learning methods and the results of this study will have great potential in the efficient development of safer drugs.
Collapse
Affiliation(s)
| | - Kristen Matsuno
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Jiang Yao
- Dassault Systèmes Simulia Corporation, Johnston, RI 02919, USA
| | - Paris Perdikaris
- Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Ellen Kuhl
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
65
|
Loewe A, Poremba E, Oesterlein T, Luik A, Schmitt C, Seemann G, Dössel O. Patient-Specific Identification of Atrial Flutter Vulnerability-A Computational Approach to Reveal Latent Reentry Pathways. Front Physiol 2019; 9:1910. [PMID: 30692934 PMCID: PMC6339942 DOI: 10.3389/fphys.2018.01910] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2018] [Accepted: 12/18/2018] [Indexed: 11/23/2022] Open
Abstract
Atypical atrial flutter (AFlut) is a reentrant arrhythmia which patients frequently develop after ablation for atrial fibrillation (AF). Indeed, substrate modifications during AF ablation can increase the likelihood to develop AFlut and it is clinically not feasible to reliably and sensitively test if a patient is vulnerable to AFlut. Here, we present a novel method based on personalized computational models to identify pathways along which AFlut can be sustained in an individual patient. We build a personalized model of atrial excitation propagation considering the anatomy as well as the spatial distribution of anisotropic conduction velocity and repolarization characteristics based on a combination of a priori knowledge on the population level and information derived from measurements performed in the individual patient. The fast marching scheme is employed to compute activation times for stimuli from all parts of the atria. Potential flutter pathways are then identified by tracing loops from wave front collision sites and constricting them using a geometric snake approach under consideration of the heterogeneous wavelength condition. In this way, all pathways along which AFlut can be sustained are identified. Flutter pathways can be instantiated by using an eikonal-diffusion phase extrapolation approach and a dynamic multifront fast marching simulation. In these dynamic simulations, the initial pattern eventually turns into the one driven by the dominant pathway, which is the only pathway that can be observed clinically. We assessed the sensitivity of the flutter pathway maps with respect to conduction velocity and its anisotropy. Moreover, we demonstrate the application of tailored models considering disease-specific repolarization properties (healthy, AF-remodeled, potassium channel mutations) as well as applicabiltiy on a clinical dataset. Finally, we tested how AFlut vulnerability of these substrates is modulated by exemplary antiarrhythmic drugs (amiodarone, dronedarone). Our novel method allows to assess the vulnerability of an individual patient to develop AFlut based on the personal anatomical, electrophysiological, and pharmacological characteristics. In contrast to clinical electrophysiological studies, our computational approach provides the means to identify all possible AFlut pathways and not just the currently dominant one. This allows to consider all relevant AFlut pathways when tailoring clinical ablation therapy in order to reduce the development and recurrence of AFlut.
Collapse
Affiliation(s)
- Axel Loewe
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Emanuel Poremba
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Tobias Oesterlein
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Armin Luik
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Karlsruhe, Germany
| | - Claus Schmitt
- Medizinische Klinik IV, Städtisches Klinikum Karlsruhe, Karlsruhe, Germany
| | - Gunnar Seemann
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
- Institute for Experimental Cardiovascular Medicine, University Heart Center Freiburg Bad Krozingen, Freiburg, Germany
- Faculty of Medicine, Albert-Ludwigs University, Freiburg, Germany
| | - Olaf Dössel
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| |
Collapse
|
66
|
Gsell MAF, Augustin CM, Prassl AJ, Karabelas E, Fernandes JF, Kelm M, Goubergrits L, Kuehne T, Plank G. Assessment of wall stresses and mechanical heart power in the left ventricle: Finite element modeling versus Laplace analysis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e3147. [PMID: 30151998 PMCID: PMC6492182 DOI: 10.1002/cnm.3147] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 07/19/2018] [Accepted: 08/14/2018] [Indexed: 05/30/2023]
Abstract
INTRODUCTION Stenotic aortic valve disease (AS) causes pressure overload of the left ventricle (LV) that may trigger adverse remodeling and precipitate progression towards heart failure (HF). As myocardial energetics can be impaired during AS, LV wall stresses and biomechanical power provide a complementary view of LV performance that may aide in better assessing the state of disease. OBJECTIVES Using a high-resolution electro-mechanical (EM) in silico model of the LV as a reference, we evaluated clinically feasible Laplace-based methods for assessing global LV wall stresses and biomechanical power. METHODS We used N = 4 in silico finite element (FE) EM models of LV and aorta of patients suffering from AS. All models were personalized with clinical data under pretreatment conditions. Left ventricle wall stresses and biomechanical power were computed accurately from FE kinematic data and compared with Laplace-based estimation methods, which were applied to the same FE model data. RESULTS AND CONCLUSION Laplace estimates of LV wall stress are able to provide a rough approximation of global mean stress in the circumferential-longitudinal plane of the LV. However, according to FE results, spatial heterogeneity of stresses in the LV wall is significant, leading to major discrepancies between local stresses and global mean stress. Assessment of mechanical power with Laplace methods is feasible, but these are inferior in accuracy compared with FE models. The accurate assessment of stress and power density distribution in the LV wall is only feasible based on patient-specific FE modeling.
Collapse
Affiliation(s)
| | - Christoph M. Augustin
- Institute of BiophysicsMedical University of GrazGrazAustria
- Department of Mechanical EngineeringUniversity of CaliforniaBerkleyCalifornia
| | - Anton J. Prassl
- Institute of BiophysicsMedical University of GrazGrazAustria
| | - Elias Karabelas
- Institute of BiophysicsMedical University of GrazGrazAustria
| | - Joao F. Fernandes
- Institute for Cardiovascular Computer‐assisted MedicineCharité ‐ Universitätsmedizin BerlinBerlinGermany
| | - Marcus Kelm
- Institute for Cardiovascular Computer‐assisted MedicineCharité ‐ Universitätsmedizin BerlinBerlinGermany
- Department of Congenital Heart Disease/Pediatric CardiologyGerman Heart Institute BerlinBerlinGermany
| | - Leonid Goubergrits
- Institute for Cardiovascular Computer‐assisted MedicineCharité ‐ Universitätsmedizin BerlinBerlinGermany
| | - Titus Kuehne
- Institute for Cardiovascular Computer‐assisted MedicineCharité ‐ Universitätsmedizin BerlinBerlinGermany
- Department of Congenital Heart Disease/Pediatric CardiologyGerman Heart Institute BerlinBerlinGermany
| | - Gernot Plank
- Institute of BiophysicsMedical University of GrazGrazAustria
| |
Collapse
|
67
|
Santiago A, Aguado-Sierra J, Zavala-Aké M, Doste-Beltran R, Gómez S, Arís R, Cajas JC, Casoni E, Vázquez M. Fully coupled fluid-electro-mechanical model of the human heart for supercomputers. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e3140. [PMID: 30117302 DOI: 10.1002/cnm.3140] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 04/28/2018] [Accepted: 07/22/2018] [Indexed: 05/12/2023]
Abstract
In this work, we present a fully coupled fluid-electro-mechanical model of a 50th percentile human heart. The model is implemented on Alya, the BSC multi-physics parallel code, capable of running efficiently in supercomputers. Blood in the cardiac cavities is modeled by the incompressible Navier-Stokes equations and an arbitrary Lagrangian-Eulerian (ALE) scheme. Electrophysiology is modeled with a monodomain scheme and the O'Hara-Rudy cell model. Solid mechanics is modeled with a total Lagrangian formulation for discrete strains using the Holzapfel-Ogden cardiac tissue material model. The three problems are simultaneously and bidirectionally coupled through an electromechanical feedback and a fluid-structure interaction scheme. In this paper, we present the scheme in detail and propose it as a computational cardiac workbench.
Collapse
Affiliation(s)
- Alfonso Santiago
- Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC), Barcelona, Spain
| | - Jazmín Aguado-Sierra
- Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC), Barcelona, Spain
| | - Miguel Zavala-Aké
- Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC), Barcelona, Spain
| | | | - Samuel Gómez
- Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC), Barcelona, Spain
| | - Ruth Arís
- Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC), Barcelona, Spain
| | - Juan C Cajas
- Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC), Barcelona, Spain
| | - Eva Casoni
- Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC), Barcelona, Spain
| | - Mariano Vázquez
- Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Center (BSC), Barcelona, Spain
- Instituto de Investigación en Inteligencia Artificial (IIIA), Consejo Superior de Investigaciones Científicas (CSIC), Barcelona, Spain
| |
Collapse
|
68
|
Arens S, Dierckx H, Panfilov AV. GEMS: A Fully Integrated PETSc-Based Solver for Coupled Cardiac Electromechanics and Bidomain Simulations. Front Physiol 2018; 9:1431. [PMID: 30386252 PMCID: PMC6198176 DOI: 10.3389/fphys.2018.01431] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Accepted: 09/20/2018] [Indexed: 01/23/2023] Open
Abstract
Cardiac contraction is coordinated by a wave of electrical excitation which propagates through the heart. Combined modeling of electrical and mechanical function of the heart provides the most comprehensive description of cardiac function and is one of the latest trends in cardiac research. The effective numerical modeling of cardiac electromechanics remains a challenge, due to the stiffness of the electrical equations and the global coupling in the mechanical problem. Here we present a short review of the inherent assumptions made when deriving the electromechanical equations, including a general representation for deformation-dependent conduction tensors obeying orthotropic symmetry, and then present an implicit-explicit time-stepping approach that is tailored to solving the cardiac mono- or bidomain equations coupled to electromechanics of the cardiac wall. Our approach allows to find numerical solutions of the electromechanics equations using stable and higher order time integration. Our methods are implemented in a monolithic finite element code GEMS (Ghent Electromechanics Solver) using the PETSc library that is inherently parallelized for use on high-performance computing infrastructure. We tested GEMS on standard benchmark computations and discuss further development of our software.
Collapse
Affiliation(s)
- Sander Arens
- Department of Physics and Astronomy, Ghent University, Ghent, Belgium
| | - Hans Dierckx
- Department of Physics and Astronomy, Ghent University, Ghent, Belgium
| | - Alexander V Panfilov
- Department of Physics and Astronomy, Ghent University, Ghent, Belgium.,Laboratory of Computational Biology and Medicine, Ural Federal University, Ekaterinburg, Russia
| |
Collapse
|
69
|
Jilberto J, Hurtado DE. Semi-implicit Non-conforming Finite-Element Schemes for Cardiac Electrophysiology: A Framework for Mesh-Coarsening Heart Simulations. Front Physiol 2018; 9:1513. [PMID: 30425648 PMCID: PMC6218665 DOI: 10.3389/fphys.2018.01513] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Accepted: 10/09/2018] [Indexed: 11/13/2022] Open
Abstract
The field of computational cardiology has steadily progressed toward reliable and accurate simulations of the heart, showing great potential in clinical applications such as the optimization of cardiac interventions and the study of pro-arrhythmic effects of drugs in humans, among others. However, the computational effort demanded by in-silico studies of the heart remains challenging, highlighting the need of novel numerical methods that can improve the efficiency of simulations while targeting an acceptable accuracy. In this work, we propose a semi-implicit non-conforming finite-element scheme (SINCFES) suitable for cardiac electrophysiology simulations. The accuracy and efficiency of the proposed scheme are assessed by means of numerical simulations of the electrical excitation and propagation in regular and biventricular geometries. We show that the SINCFES allows for coarse-mesh simulations that reduce the computation time when compared to fine-mesh models while delivering wavefront shapes and conduction velocities that are more accurate than those predicted by traditional finite-element formulations based on the same coarse mesh, thus improving the accuracy-efficiency trade-off of cardiac simulations.
Collapse
Affiliation(s)
- Javiera Jilberto
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Daniel E. Hurtado
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
70
|
Roy A, Varela M, Aslanidi O. Image-Based Computational Evaluation of the Effects of Atrial Wall Thickness and Fibrosis on Re-entrant Drivers for Atrial Fibrillation. Front Physiol 2018; 9:1352. [PMID: 30349483 PMCID: PMC6187302 DOI: 10.3389/fphys.2018.01352] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2018] [Accepted: 09/06/2018] [Indexed: 12/19/2022] Open
Abstract
Introduction: Catheter ablation (CA) is a common treatment for atrial fibrillation (AF), but the knowledge of optimal ablation sites, and hence clinical outcomes, are suboptimal. Increasing evidence suggest that ablation strategies based on patient-specific substrates information, such as distributions of fibrosis and atrial wall thickness (AWT), may be used to improve therapy. We hypothesized that competing influences of large AWT gradients and fibrotic patches on conductive properties of atrial tissue can determine locations of re-entrant drivers (RDs) sustaining AF. Methods: Two sets of models were used: (1) a simple model of 3D atrial tissue slab with a step change in AWT and a synthetic fibrosis patch, and (2) 3D models based on patient-specific right atrial (RA) and left atrial (LA) geometries. The latter were obtained from four healthy volunteers and two AF patients, respectively, using magnetic resonance imaging (MRI). A synthetic fibrotic patch was added in the RA and fibrosis distributions in the LA were obtained from gadolinium-enhanced MRI of the same patients. In all models, 3D geometry was combined with the Fenton-Karma atrial cell model to simulate RDs. Results: In the slab, RDs drifted toward, and then along the AWT step. However, with additional fibrosis, the RDs were localized in regions between the step and fibrosis. In the RA, RDs drifted toward and anchored to a large AWT gradient between the crista terminalis (CT) region and the surrounding atrial wall. Without such a gradient, RDs drifted toward the superior vena cava (SVC) or the tricuspid valve (TSV). With additional fibrosis, RDs initiated away from the CT anchored to the fibrotic patch, whereas RDs initiated close to the CT region remained localized between the two structures. In the LA, AWT was more uniform and RDs drifted toward the pulmonary veins (PVs). However, with additional fibrotic patches, RDs either anchored to them or multiplied. Conclusion: In the RA, RD locations are determined by both fibrosis and AWT gradients at the CT region. In the LA, they are determined by fibrosis due to the absence of large AWT gradients. These results elucidate mechanisms behind the stabilization of RDs sustaining AF and can help guide ablation therapy.
Collapse
Affiliation(s)
| | | | - Oleg Aslanidi
- Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London, United Kingdom
| |
Collapse
|
71
|
Alessandrini M, Valinoti M, Unger L, Oesterlein T, Dössel O, Corsi C, Loewe A, Severi S. A Computational Framework to Benchmark Basket Catheter Guided Ablation in Atrial Fibrillation. Front Physiol 2018; 9:1251. [PMID: 30298012 PMCID: PMC6161611 DOI: 10.3389/fphys.2018.01251] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 08/20/2018] [Indexed: 11/13/2022] Open
Abstract
Catheter ablation is a curative therapeutic approach for atrial fibrillation (AF). Ablation of rotational sources based on basket catheter measurements has been proposed as a promising approach in patients with persistent AF to complement pulmonary vein isolation. However, clinically reported success rates are equivocal calling for a mechanistic investigation under controlled conditions. We present a computational framework to benchmark ablation strategies considering the whole cycle from excitation propagation to electrogram acquisition and processing to virtual therapy. Fibrillation was induced in a patient-specific 3D volumetric model of the left atrium, which was homogeneously remodeled to sustain reentry. The resulting extracellular potential field was sampled using models of grid catheters as well as realistically deformed basket catheters considering the specific atrial anatomy. The virtual electrograms were processed to compute phase singularity density maps to target rotor tips with up to three circular ablations. Stable rotors were successfully induced in different regions of the homogeneously remodeled atrium showing that rotors are not constrained to unique anatomical structures or locations. Density maps of rotor tip trajectories correctly identified and located the rotors (deviation < 10 mm) based on catheter recordings only for sufficient resolution (inter-electrode distance ≤3 mm) and proximity to the wall (≤10 mm). Targeting rotor sites with ablation did not stop reentries in the homogeneously remodeled atria independent from lesion size (1-7 mm radius), from linearly connecting lesions with anatomical obstacles, and from the number of rotors targeted sequentially (≤3). Our results show that phase maps derived from intracardiac electrograms can be a powerful tool to map atrial activation patterns, yet they can also be misleading due to inaccurate localization of the rotor tip depending on electrode resolution and distance to the wall. This should be considered to avoid ablating regions that are in fact free of rotor sources of AF. In our experience, ablation of rotor sites was not successful to stop fibrillation. Our comprehensive simulation framework provides the means to holistically benchmark ablation strategies in silico under consideration of all steps involved in electrogram-based therapy and, in future, could be used to study more heterogeneously remodeled disease states as well.
Collapse
Affiliation(s)
- Martino Alessandrini
- Department of Electronic Engineering and Information Technology, University of Bologna, Cesena, Italy
| | - Maddalena Valinoti
- Department of Electronic Engineering and Information Technology, University of Bologna, Cesena, Italy
| | - Laura Unger
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Tobias Oesterlein
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Olaf Dössel
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Cristiana Corsi
- Department of Electronic Engineering and Information Technology, University of Bologna, Cesena, Italy
| | - Axel Loewe
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Stefano Severi
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany
| |
Collapse
|
72
|
Ni H, Morotti S, Grandi E. A Heart for Diversity: Simulating Variability in Cardiac Arrhythmia Research. Front Physiol 2018; 9:958. [PMID: 30079031 PMCID: PMC6062641 DOI: 10.3389/fphys.2018.00958] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 06/29/2018] [Indexed: 12/31/2022] Open
Abstract
In cardiac electrophysiology, there exist many sources of inter- and intra-personal variability. These include variability in conditions and environment, and genotypic and molecular diversity, including differences in expression and behavior of ion channels and transporters, which lead to phenotypic diversity (e.g., variable integrated responses at the cell, tissue, and organ levels). These variabilities play an important role in progression of heart disease and arrhythmia syndromes and outcomes of therapeutic interventions. Yet, the traditional in silico framework for investigating cardiac arrhythmias is built upon a parameter/property-averaging approach that typically overlooks the physiological diversity. Inspired by work done in genetics and neuroscience, new modeling frameworks of cardiac electrophysiology have been recently developed that take advantage of modern computational capabilities and approaches, and account for the variance in the biological data they are intended to illuminate. In this review, we outline the recent advances in statistical and computational techniques that take into account physiological variability, and move beyond the traditional cardiac model-building scheme that involves averaging over samples from many individuals in the construction of a highly tuned composite model. We discuss how these advanced methods have harnessed the power of big (simulated) data to study the mechanisms of cardiac arrhythmias, with a special emphasis on atrial fibrillation, and improve the assessment of proarrhythmic risk and drug response. The challenges of using in silico approaches with variability are also addressed and future directions are proposed.
Collapse
Affiliation(s)
| | | | - Eleonora Grandi
- Department of Pharmacology, University of California, Davis, Davis, CA, United States
| |
Collapse
|
73
|
Corrado C, Williams S, Karim R, Plank G, O'Neill M, Niederer S. A work flow to build and validate patient specific left atrium electrophysiology models from catheter measurements. Med Image Anal 2018; 47:153-163. [PMID: 29753180 PMCID: PMC5998385 DOI: 10.1016/j.media.2018.04.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 02/16/2018] [Accepted: 04/19/2018] [Indexed: 11/19/2022]
Abstract
Biophysical models of the atrium provide a physically constrained framework for describing the current state of an atrium and allow predictions of how that atrium will respond to therapy. We propose a work flow to simulate patient specific electrophysiological heterogeneity from clinical data and validate the resulting biophysical models. In 7 patients, we recorded the atrial anatomy with an electroanatomical mapping system (St Jude Velocity); we then applied an S1-S2 electrical stimulation protocol from the coronary sinus (CS) and the high right atrium (HRA) whilst recording the activation patterns using a PentaRay catheter with 10 bipolar electrodes at 12 ± 2 sites across the atrium. Using only the activation times measured with a PentaRay catheter and caused by a stimulus applied in the CS with a remote catheter we fitted the four parameters for a modified Mitchell-Schaeffer model and the tissue conductivity to the recorded local conduction velocity restitution curve and estimated local effective refractory period. Model parameters were then interpolated across each atrium. The fitted model recapitulated the S1-S2 activation times for CS pacing giving a correlation ranging between 0.81 and 0.98. The model was validated by comparing simulated activations times with the independently recorded HRA pacing S1-S2 activation times, giving a correlation ranging between 0.65 and 0.96. The resulting work flow provides the first validated cohort of models that capture clinically measured patient specific electrophysiological heterogeneity.
Collapse
Affiliation(s)
- Cesare Corrado
- Division of Imaging Sciences & Biomedical Engineering, King's College London, London SE17EH, United Kingdom.
| | - Steven Williams
- Division of Imaging Sciences & Biomedical Engineering, King's College London, London SE17EH, United Kingdom
| | - Rashed Karim
- Division of Imaging Sciences & Biomedical Engineering, King's College London, London SE17EH, United Kingdom
| | - Gernot Plank
- Department of Biophysics, Medical University of Graz, Neue Stiftingtalstraße 6/IV, 8010 Graz, Austria
| | - Mark O'Neill
- Division of Imaging Sciences & Biomedical Engineering, King's College London, London SE17EH, United Kingdom
| | - Steven Niederer
- Division of Imaging Sciences & Biomedical Engineering, King's College London, London SE17EH, United Kingdom
| |
Collapse
|
74
|
Godoy EJ, Lozano M, García-Fernández I, Ferrer-Albero A, MacLeod R, Saiz J, Sebastian R. Atrial Fibrosis Hampers Non-invasive Localization of Atrial Ectopic Foci From Multi-Electrode Signals: A 3D Simulation Study. Front Physiol 2018; 9:404. [PMID: 29867517 PMCID: PMC5968126 DOI: 10.3389/fphys.2018.00404] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Accepted: 04/04/2018] [Indexed: 12/13/2022] Open
Abstract
Introduction: Focal atrial tachycardia is commonly treated by radio frequency ablation with an acceptable long-term success. Although the location of ectopic foci tends to appear in specific hot-spots, they can be located virtually in any atrial region. Multi-electrode surface ECG systems allow acquiring dense body surface potential maps (BSPM) for non-invasive therapy planning of cardiac arrhythmia. However, the activation of the atria could be affected by fibrosis and therefore biomarkers based on BSPM need to take these effects into account. We aim to analyze the effect of fibrosis on a BSPM derived index, and its potential application to predict the location of ectopic foci in the atria. Methodology: We have developed a 3D atrial model that includes 5 distributions of patchy fibrosis in the left atrium at 5 different stages. Each stage corresponds to a different amount of fibrosis that ranges from 2 to 40%. The 25 resulting 3D models were used for simulation of Focal Atrial Tachycardia (FAT), triggered from 19 different locations described in clinical studies. BSPM were obtained for all simulations, and the body surface potential integral maps (BSPiM) were calculated to describe atrial activations. A machine learning (ML) pipeline using a supervised learning model and support vector machine was developed to learn the BSPM patterns of each of the 475 activation sequences and relate them to the origin of the FAT source. Results: Activation maps for stages with more than 15% of fibrosis were greatly affected, producing conduction blocks and delays in propagation. BSPiMs did not always cluster into non-overlapped groups since BSPiMs were highly altered by the conduction blocks. From stage 3 (15% fibrosis) the BSPiMs showed differences for ectopic beats placed around the area of the pulmonary veins. Classification results were mostly above 84% for all the configurations studied when a large enough number of electrodes were used to map the torso. However, the presence of fibrosis increases the area of the ectopic focus location and therefore decreases the utility for the electrophysiologist. Conclusions: The results indicate that the proposed ML pipeline is a promising methodology for non-invasive ectopic foci localization from BSPM signal even when fibrosis is present.
Collapse
Affiliation(s)
- Eduardo Jorge Godoy
- Computational Multiscale Simulation Lab, Department of Computer Science, Universitat de Valencia, Valencia, Spain
| | - Miguel Lozano
- Computational Multiscale Simulation Lab, Department of Computer Science, Universitat de Valencia, Valencia, Spain
| | - Ignacio García-Fernández
- Computational Multiscale Simulation Lab, Department of Computer Science, Universitat de Valencia, Valencia, Spain
| | - Ana Ferrer-Albero
- Computational Multiscale Simulation Lab, Department of Computer Science, Universitat de Valencia, Valencia, Spain
| | - Rob MacLeod
- Department of Bioengineering, Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT, United States
| | - Javier Saiz
- Centro de Investigación en Bioingeniería, Universitat Politécnica de Valencia, Valencia, Spain
| | - Rafael Sebastian
- Computational Multiscale Simulation Lab, Department of Computer Science, Universitat de Valencia, Valencia, Spain
| |
Collapse
|
75
|
Sahli Costabal F, Yao J, Kuhl E. Predicting drug-induced arrhythmias by multiscale modeling. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e2964. [PMID: 29424967 DOI: 10.1002/cnm.2964] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Revised: 01/23/2018] [Accepted: 01/27/2018] [Indexed: 06/08/2023]
Abstract
Drugs often have undesired side effects. In the heart, they can induce lethal arrhythmias such as torsades de pointes. The risk evaluation of a new compound is costly and can take a long time, which often hinders the development of new drugs. Here, we establish a high-resolution, multiscale computational model to quickly assess the cardiac toxicity of new and existing drugs. The input of the model is the drug-specific current block from single cell electrophysiology; the output is the spatio-temporal activation profile and the associated electrocardiogram. We demonstrate the potential of our model for a low-risk drug, ranolazine, and a high-risk drug, quinidine: For ranolazine, our model predicts a prolonged QT interval of 19.4% compared with baseline and a regular sinus rhythm at 60.15 beats per minute. For quinidine, our model predicts a prolonged QT interval of 78.4% and a spontaneous development of torsades de pointes both in the activation profile and in the electrocardiogram. Our model reveals the mechanisms by which electrophysiological abnormalities propagate across the spatio-temporal scales, from specific channel blockage, via altered single cell action potentials and prolonged QT intervals, to the spontaneous emergence of ventricular tachycardia in the form of torsades de pointes. Our model could have important implications for researchers, regulatory agencies, and pharmaceutical companies on rationalizing safe drug development and reducing the time-to-market of new drugs.
Collapse
Affiliation(s)
| | - Jiang Yao
- Dassault Systèmes Simulia Corporation, Johnston, RI, USA
| | - Ellen Kuhl
- Departments of Mechanical Engineering, Bioengineering, and Cardiothoracic Surgery, Stanford University, Stanford, CA, USA
| |
Collapse
|
76
|
Hoermann JM, Bertoglio C, Kronbichler M, Pfaller MR, Chabiniok R, Wall WA. An adaptive hybridizable discontinuous Galerkin approach for cardiac electrophysiology. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e2959. [PMID: 29316340 DOI: 10.1002/cnm.2959] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Revised: 12/13/2017] [Accepted: 12/27/2017] [Indexed: 06/07/2023]
Abstract
Cardiac electrophysiology simulations are numerically challenging because of the propagation of a steep electrochemical wave front and thus require discretizations with small mesh sizes to obtain accurate results. In this work, we present an approach based on the hybridizable discontinuous Galerkin method (HDG), which allows an efficient implementation of high-order discretizations into a computational framework. In particular, using the advantage of the discontinuous function space, we present an efficient p-adaptive strategy for accurately tracking the wave front. The HDG allows to reduce the overall degrees of freedom in the final linear system to those only on the element interfaces. Additionally, we propose a rule for a suitable integration accuracy for the ionic current term depending on the polynomial order and the cell model to handle high-order polynomials. Our results show that for the same number of degrees of freedom, coarse high-order elements provide more accurate results than fine low-order elements. Introducing p-adaptivity further reduces computational costs while maintaining accuracy by restricting the use of high-order elements to resolve the wave front. For a patient-specific simulation of a cardiac cycle, p-adaptivity reduces the average number of degrees of freedom by 95% compared to the nonadaptive model. In addition to reducing computational costs, using coarse meshes with our p-adaptive high-order HDG method also simplifies practical aspects of mesh generation and postprocessing.
Collapse
Affiliation(s)
- Julia M Hoermann
- Institute for Computational Mechanics, Technical University Munich, Boltzmannstr 15, Garching b. München, 85748, Germany
| | - Cristóbal Bertoglio
- Center for Mathematical Modeling, Universidad de Chile, Beaucheff 851, Santiago 8370456, Chile
- Johann Bernoulli Institute, University of Groningen, Nijenborgh 9, Groningen, 9747 HZ, Netherlands
| | - Martin Kronbichler
- Institute for Computational Mechanics, Technical University Munich, Boltzmannstr 15, Garching b. München, 85748, Germany
| | - Martin R Pfaller
- Institute for Computational Mechanics, Technical University Munich, Boltzmannstr 15, Garching b. München, 85748, Germany
| | - Radomir Chabiniok
- Inria, Paris-Saclay University, Palaiseau, France
- LMS, Ecole Polytechnique, CNRS, Paris-Saclay University, Palaiseau, France
- School of Biomedical Engineering and Imaging Sciences (BMEIS), St Thomas' Hospital, King's College, London, UK
| | - Wolfgang A Wall
- Institute for Computational Mechanics, Technical University Munich, Boltzmannstr 15, Garching b. München, 85748, Germany
| |
Collapse
|
77
|
Potse M. Scalable and Accurate ECG Simulation for Reaction-Diffusion Models of the Human Heart. Front Physiol 2018; 9:370. [PMID: 29731720 PMCID: PMC5920200 DOI: 10.3389/fphys.2018.00370] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Accepted: 03/27/2018] [Indexed: 11/13/2022] Open
Abstract
Realistic electrocardiogram (ECG) simulation with numerical models is important for research linking cellular and molecular physiology to clinically observable signals, and crucial for patient tailoring of numerical heart models. However, ECG simulation with a realistic torso model is computationally much harder than simulation of cardiac activity itself, so that many studies with sophisticated heart models have resorted to crude approximations of the ECG. This paper shows how the classical concept of electrocardiographic lead fields can be used for an ECG simulation method that matches the realism of modern heart models. The accuracy and resource requirements were compared to those of a full-torso solution for the potential and scaling was tested up to 14,336 cores with a heart model consisting of 11 million nodes. Reference ECGs were computed on a 3.3 billion-node heart-torso mesh at 0.2 mm resolution. The results show that the lead-field method is more efficient than a full-torso solution when the number of simulated samples is larger than the number of computed ECG leads. While the initial computation of the lead fields remains a hard and poorly scalable problem, the ECG computation itself scales almost perfectly and, even for several hundreds of ECG leads, takes much less time than the underlying simulation of cardiac activity.
Collapse
Affiliation(s)
- Mark Potse
- CARMEN Research Team, Inria Bordeaux Sud-Ouest, Talence, France.,Institut de Mathématiques de Bordeaux, UMR 5251, Université de Bordeaux, Talence, France.,IHU Liryc, Electrophysiology and Heart Modeling Institute, Foundation Bordeaux Université, Pessac-Bordeaux, France
| |
Collapse
|
78
|
Pathmanathan P, Gray RA. Validation and Trustworthiness of Multiscale Models of Cardiac Electrophysiology. Front Physiol 2018; 9:106. [PMID: 29497385 PMCID: PMC5818422 DOI: 10.3389/fphys.2018.00106] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Accepted: 01/31/2018] [Indexed: 02/06/2023] Open
Abstract
Computational models of cardiac electrophysiology have a long history in basic science applications and device design and evaluation, but have significant potential for clinical applications in all areas of cardiovascular medicine, including functional imaging and mapping, drug safety evaluation, disease diagnosis, patient selection, and therapy optimisation or personalisation. For all stakeholders to be confident in model-based clinical decisions, cardiac electrophysiological (CEP) models must be demonstrated to be trustworthy and reliable. Credibility, that is, the belief in the predictive capability, of a computational model is primarily established by performing validation, in which model predictions are compared to experimental or clinical data. However, there are numerous challenges to performing validation for highly complex multi-scale physiological models such as CEP models. As a result, credibility of CEP model predictions is usually founded upon a wide range of distinct factors, including various types of validation results, underlying theory, evidence supporting model assumptions, evidence from model calibration, all at a variety of scales from ion channel to cell to organ. Consequently, it is often unclear, or a matter for debate, the extent to which a CEP model can be trusted for a given application. The aim of this article is to clarify potential rationale for the trustworthiness of CEP models by reviewing evidence that has been (or could be) presented to support their credibility. We specifically address the complexity and multi-scale nature of CEP models which makes traditional model evaluation difficult. In addition, we make explicit some of the credibility justification that we believe is implicitly embedded in the CEP modeling literature. Overall, we provide a fresh perspective to CEP model credibility, and build a depiction and categorisation of the wide-ranging body of credibility evidence for CEP models. This paper also represents a step toward the extension of model evaluation methodologies that are currently being developed by the medical device community, to physiological models.
Collapse
Affiliation(s)
- Pras Pathmanathan
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, United States
| | | |
Collapse
|
79
|
Sachetto Oliveira R, Martins Rocha B, Burgarelli D, Meira W, Constantinides C, Weber Dos Santos R. Performance evaluation of GPU parallelization, space-time adaptive algorithms, and their combination for simulating cardiac electrophysiology. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e2913. [PMID: 28636811 DOI: 10.1002/cnm.2913] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 06/09/2017] [Accepted: 06/16/2017] [Indexed: 05/23/2023]
Abstract
The use of computer models as a tool for the study and understanding of the complex phenomena of cardiac electrophysiology has attained increased importance nowadays. At the same time, the increased complexity of the biophysical processes translates into complex computational and mathematical models. To speed up cardiac simulations and to allow more precise and realistic uses, 2 different techniques have been traditionally exploited: parallel computing and sophisticated numerical methods. In this work, we combine a modern parallel computing technique based on multicore and graphics processing units (GPUs) and a sophisticated numerical method based on a new space-time adaptive algorithm. We evaluate each technique alone and in different combinations: multicore and GPU, multicore and GPU and space adaptivity, multicore and GPU and space adaptivity and time adaptivity. All the techniques and combinations were evaluated under different scenarios: 3D simulations on slabs, 3D simulations on a ventricular mouse mesh, ie, complex geometry, sinus-rhythm, and arrhythmic conditions. Our results suggest that multicore and GPU accelerate the simulations by an approximate factor of 33×, whereas the speedups attained by the space-time adaptive algorithms were approximately 48. Nevertheless, by combining all the techniques, we obtained speedups that ranged between 165 and 498. The tested methods were able to reduce the execution time of a simulation by more than 498× for a complex cellular model in a slab geometry and by 165× in a realistic heart geometry simulating spiral waves. The proposed methods will allow faster and more realistic simulations in a feasible time with no significant loss of accuracy.
Collapse
Affiliation(s)
- Rafael Sachetto Oliveira
- Departamento de Ciência da Computação, Universidade Federal de São João de Rei, São João del-rei MG, Brazil
| | - Bernardo Martins Rocha
- Departamento de Ciência da Computação e Programa em Modelagem Computacional, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, Brazil
| | - Denise Burgarelli
- Departamento de Matemática, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| | - Wagner Meira
- Departamento de Ciência da Computação, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| | | | - Rodrigo Weber Dos Santos
- Departamento de Ciência da Computação e Programa em Modelagem Computacional, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, Brazil
| |
Collapse
|
80
|
Sahli Costabal F, Yao J, Kuhl E. Predicting the cardiac toxicity of drugs using a novel multiscale exposure-response simulator. Comput Methods Biomech Biomed Engin 2018; 21:232-246. [PMID: 29493299 PMCID: PMC6361171 DOI: 10.1080/10255842.2018.1439479] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
A common but serious side effect of many drugs is torsades de pointes, a rhythm disorder that can have fatal consequences. Torsadogenic risk has traditionally been associated with blockage of a specific potassium channel and an increased recovery period in the electrocardiogram. However, the mechanisms that trigger torsades de pointes remain incompletely understood. Here we establish a computational model to explore how drug-induced effects propagate from the single channel, via the single cell, to the whole heart level. Our mechanistic exposure-response simulator translates block-concentration characteristics for arbitrary drugs into three-dimensional excitation profiles and electrocardiogram recordings to rapidly assess torsadogenic risk. For the drug of dofetilide, we show that this risk is highly dose-dependent: at a concentration of 1x, QT prolongation is 55% but the heart maintains its regular sinus rhythm; at 5.7x, QT prolongation is 102% and the heart spontaneously transitions into torsades de points; at 30x, QT prolongation is 132% and the heart adapts a quasi-depolarized state with numerous rapidly flickering local excitations. Our simulations suggest that neither potassium channel blockage nor QT interval prolongation alone trigger torsades de pointes. The underlying mechanism predicted by our model is early afterdepolarization, which translates into pronounced U waves in the electrocardiogram, a signature that is correctly predicted by our model. Beyond the risk assessment of existing drugs, our exposure-response simulator can become a powerful tool to optimize the co-administration of drugs and, ultimately, guide the design of new drugs toward reducing life threatening drug-induced rhythm disorders in the heart.
Collapse
Affiliation(s)
- Francisco Sahli Costabal
- a Departments of Mechanical Engineering, Bioengineering, and Cardiothoracic Surgery , Stanford University , CA , USA
| | - Jiang Yao
- b Dassault Systèmes Simulia Corporation , Johnston , RI , USA
| | - Ellen Kuhl
- a Departments of Mechanical Engineering, Bioengineering, and Cardiothoracic Surgery , Stanford University , CA , USA
| |
Collapse
|
81
|
Kallhovd S, Maleckar MM, Rognes ME. Inverse estimation of cardiac activation times via gradient-based optimization. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e2919. [PMID: 28744962 DOI: 10.1002/cnm.2919] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Revised: 06/01/2017] [Accepted: 07/20/2017] [Indexed: 06/07/2023]
Abstract
Computational modeling may provide a quantitative framework for integrating multiscale data to gain insight into mechanisms of heart disease, identify and test pharmacological and electrical therapy and interventions, and support clinical decisions. Patient-specific computational cardiac models can help guide such procedures, and cardiac inverse modeling is a promising alternative to adequately personalize these models. Indeed, full cardiac inverse modeling is currently becoming computationally feasible; however, fundamental work to assess the feasibility of emerging techniques is still needed. In this study, we use a partial differential equation-constrained optimal control approach to numerically investigate the identifiability of an initial activation sequence from synthetic (partial) observations of the extracellular potential using the bidomain approximation and 2D representations of cardiac tissue. Our results demonstrate that activation times and duration of several stimuli can be recovered even with high levels of noise, that it is sufficient to sample the observations at the electrocardiogram-relevant sampling frequency of 1 kHz, and that spatial resolutions that are coarser than the standard in electrophysiological simulations can be used. The optimization of activation times is still effective when synthetic data are generated with a different cell membrane kinetics model than optimized for. The findings thus indicate that the presented approach has potential for finding activation sequences from clinical data modalities, as an extension to existing cardiac imaging approaches.
Collapse
Affiliation(s)
- Siri Kallhovd
- Simula Research Laboratory, PO Box 134,, 1325 Lysaker, Norway
- Department of Informatics, University of Oslo, PO Box 1080,, Blindern 0316 Oslo, Norway
- Center for Cardiological Innovation, Sognsvannsveien 9, 0372 Oslo, Norway
| | - Mary M Maleckar
- Simula Research Laboratory, PO Box 134,, 1325 Lysaker, Norway
- Center for Cardiological Innovation, Sognsvannsveien 9, 0372 Oslo, Norway
- Allen Institute for Cell Science, 615 Westlake Ave,, Seattle, WA 98109, USA
| | - Marie E Rognes
- Simula Research Laboratory, PO Box 134,, 1325 Lysaker, Norway
- Department of Mathematics, University of Oslo, PO Box 1053, Blindern 0316 Oslo, Norway
- Center for Biomedical Computing, PO Box 134,, 1325 Lysaker, Norway
| |
Collapse
|
82
|
Atlas-Based Computational Analysis of Heart Shape and Function in Congenital Heart Disease. J Cardiovasc Transl Res 2018; 11:123-132. [PMID: 29294215 DOI: 10.1007/s12265-017-9778-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 12/18/2017] [Indexed: 12/18/2022]
Abstract
Approximately 1% of all babies are born with some form of congenital heart defect. Many serious forms of CHD can now be surgically corrected after birth, which has led to improved survival into adulthood. However, many patients require serial monitoring to evaluate progression of heart failure and determine timing of interventions. Accurate multidimensional quantification of regional heart shape and function is required for characterizing these patients. A computational atlas of single ventricle and biventricular heart shape and function enables quantification of remodeling in terms of z scores in relation to specific reference populations. Progression of disease can then be monitored effectively by longitudinal evaluation of z scores. A biomechanical analysis of cardiac function in relation to population variation enables investigation of the underlying mechanisms for developing pathology. Here, we summarize recent progress in this field, with examples in single ventricle and biventricular congenital pathologies.
Collapse
|
83
|
Lim B, Hwang M, Song JS, Ryu AJ, Joung B, Shim EB, Ryu H, Pak HN. Effectiveness of atrial fibrillation rotor ablation is dependent on conduction velocity: An in-silico 3-dimensional modeling study. PLoS One 2017; 12:e0190398. [PMID: 29287119 PMCID: PMC5747478 DOI: 10.1371/journal.pone.0190398] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Accepted: 12/14/2017] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND We previously reported that stable rotors are observed in in-silico human atrial fibrillation (AF) models, and are well represented by a dominant frequency (DF). In the current study, we hypothesized that the outcome of DF ablation is affected by conduction velocity (CV) conditions and examined this hypothesis using in-silico 3D-AF modeling. METHODS We integrated 3D CT images of left atrium obtained from 10 patients with persistent AF (80% male, 61.8±13.5 years old) into in-silico AF model. We compared AF maintenance durations (max 300s), spatiotemporal stabilities of DF, phase singularity (PS) number, life-span of PS, and AF termination or defragmentation rates after virtual DF ablation with 5 different CV conditions (0.2, 0.3, 0.4, 0.5, and 0.6m/s). RESULTS 1. AF maintenance duration (p<0.001), spatiotemporal mean variance of DF (p<0.001), and the number of PS (p = 0.023) showed CV dependent bimodal patterns (highest at CV0.4m/s and lowest at CV0.6m/s) consistently. 2. After 10% highest DF ablation, AF defragmentation rates were the lowest at CV0.4m/s (37.8%), but highest at CV0.5 and 0.6m/s (all 100%, p<0.001). 3. In the episodes with AF termination or defragmentation followed by 10% highest DF ablation, baseline AF maintenance duration was shorter (p<0.001), spatiotemporal mean variance of DF was lower (p = 0.014), and the number of PS was lower (p = 0.004) than those with failed AF defragmentation after DF ablation. CONCLUSION Virtual ablation of DF, which may indicate AF driver, was more likely to terminate or defragment AF with spatiotemporally stable DF, but not likely to do so in long-lasting and sustained AF conditions, depending on CV.
Collapse
Affiliation(s)
- Byounghyun Lim
- Yonsei University Health System, Seoul, Republic of Korea
| | - Minki Hwang
- Yonsei University Health System, Seoul, Republic of Korea
| | - Jun-Seop Song
- Yonsei University Health System, Seoul, Republic of Korea
| | - Ah-Jin Ryu
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, Ganwon-do, Republic of Korea
| | - Boyoung Joung
- Yonsei University Health System, Seoul, Republic of Korea
| | - Eun Bo Shim
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, Ganwon-do, Republic of Korea
| | - Hyungon Ryu
- NVIDIA, Yonsei University, Department of Mathematics, Seoul, Republic of Korea
| | - Hui-Nam Pak
- Yonsei University Health System, Seoul, Republic of Korea
| |
Collapse
|
84
|
Hurtado DE, Castro S, Madrid P. Uncertainty quantification of 2 models of cardiac electromechanics. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33. [PMID: 28474497 DOI: 10.1002/cnm.2894] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Revised: 03/17/2017] [Accepted: 05/01/2017] [Indexed: 06/07/2023]
Abstract
Computational models of the heart have reached a maturity level that render them useful for in silico studies of arrhythmia and other cardiac diseases. However, the translation to the clinic of cardiac simulations critically depends on demonstrating the accuracy, robustness, and reliability of the underlying computational models under the presence of uncertainties. In this work, we study for the first time the effect of parameter uncertainty on 2 state-of-the-art coupled models of excitation-contraction of cardiac tissue. To this end, we perform forward uncertainty propagation and sensitivity analyses to understand how variability in key maximal conductances affect selected quantities of interest, such as the action potential duration (APD90 ), maximum intracellular calcium concentration, cardiac stretch, and stress. Our results suggest a strong linear relationship between selected maximal conductances and quantities of interest for a variability in parameters up to 25%, which justifies the construction of linear response surfaces that are used to compute the empirical probability density functions of all the quantities of interest under study. For both electromechanical models analyzed, uncertainty in the material parameters associated to the passive mechanical response of cardiac tissue does not affect the duration of action potentials, neither the amplitude of intracellular calcium concentrations. Our results confirm the poor mechanoelectric feedback that classical models of cardiac electromechanics have, even under the presence of parameter uncertainty.
Collapse
Affiliation(s)
- Daniel E Hurtado
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Sebastián Castro
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Pedro Madrid
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
85
|
Gao H, Qi N, Feng L, Ma X, Danton M, Berry C, Luo X. Modelling mitral valvular dynamics-current trend and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:e2858. [PMID: 27935265 PMCID: PMC5697636 DOI: 10.1002/cnm.2858] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 09/30/2016] [Accepted: 11/26/2016] [Indexed: 05/19/2023]
Abstract
Dysfunction of mitral valve causes morbidity and premature mortality and remains a leading medical problem worldwide. Computational modelling aims to understand the biomechanics of human mitral valve and could lead to the development of new treatment, prevention and diagnosis of mitral valve diseases. Compared with the aortic valve, the mitral valve has been much less studied owing to its highly complex structure and strong interaction with the blood flow and the ventricles. However, the interest in mitral valve modelling is growing, and the sophistication level is increasing with the advanced development of computational technology and imaging tools. This review summarises the state-of-the-art modelling of the mitral valve, including static and dynamics models, models with fluid-structure interaction, and models with the left ventricle interaction. Challenges and future directions are also discussed.
Collapse
Affiliation(s)
- Hao Gao
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | - Nan Qi
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | - Liuyang Feng
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | | | - Mark Danton
- Department of Cardiac SurgeryRoyal Hospital for ChildrenGlasgowUK
| | - Colin Berry
- Institute of Cardiovascular and Medical SciencesUniversity of GlasgowUK
| | - Xiaoyu Luo
- School of Mathematics and StatisticsUniversity of GlasgowUK
| |
Collapse
|
86
|
Neic A, Campos FO, Prassl AJ, Niederer SA, Bishop MJ, Vigmond EJ, Plank G. Efficient computation of electrograms and ECGs in human whole heart simulations using a reaction-eikonal model. JOURNAL OF COMPUTATIONAL PHYSICS 2017; 346:191-211. [PMID: 28819329 PMCID: PMC5555399 DOI: 10.1016/j.jcp.2017.06.020] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Anatomically accurate and biophysically detailed bidomain models of the human heart have proven a powerful tool for gaining quantitative insight into the links between electrical sources in the myocardium and the concomitant current flow in the surrounding medium as they represent their relationship mechanistically based on first principles. Such models are increasingly considered as a clinical research tool with the perspective of being used, ultimately, as a complementary diagnostic modality. An important prerequisite in many clinical modeling applications is the ability of models to faithfully replicate potential maps and electrograms recorded from a given patient. However, while the personalization of electrophysiology models based on the gold standard bidomain formulation is in principle feasible, the associated computational expenses are significant, rendering their use incompatible with clinical time frames. In this study we report on the development of a novel computationally efficient reaction-eikonal (R-E) model for modeling extracellular potential maps and electrograms. Using a biventricular human electrophysiology model, which incorporates a topologically realistic His-Purkinje system (HPS), we demonstrate by comparing against a high-resolution reaction-diffusion (R-D) bidomain model that the R-E model predicts extracellular potential fields, electrograms as well as ECGs at the body surface with high fidelity and offers vast computational savings greater than three orders of magnitude. Due to their efficiency R-E models are ideally suitable for forward simulations in clinical modeling studies which attempt to personalize electrophysiological model features.
Collapse
Affiliation(s)
- Aurel Neic
- Institute of Biophysics, Medical University of Graz, Graz, Austria
| | - Fernando O. Campos
- Institute of Biophysics, Medical University of Graz, Graz, Austria
- Dept. of Congenital Heart Diseases and Pediatric Cardiology, German Heart Institute Berlin, Berlin, Germany
| | - Anton J. Prassl
- Institute of Biophysics, Medical University of Graz, Graz, Austria
| | - Steven A. Niederer
- Dept. Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King’s College of London, London, United Kingdom
| | - Martin J. Bishop
- Dept. Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King’s College of London, London, United Kingdom
| | | | - Gernot Plank
- Institute of Biophysics, Medical University of Graz, Graz, Austria
- Corresponding author. (G. Plank)
| |
Collapse
|
87
|
Gizzi A, Loppini A, Ruiz-Baier R, Ippolito A, Camassa A, La Camera A, Emmi E, Di Perna L, Garofalo V, Cherubini C, Filippi S. Nonlinear diffusion and thermo-electric coupling in a two-variable model of cardiac action potential. CHAOS (WOODBURY, N.Y.) 2017; 27:093919. [PMID: 28964112 DOI: 10.1063/1.4999610] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This work reports the results of the theoretical investigation of nonlinear dynamics and spiral wave breakup in a generalized two-variable model of cardiac action potential accounting for thermo-electric coupling and diffusion nonlinearities. As customary in excitable media, the common Q10 and Moore factors are used to describe thermo-electric feedback in a 10° range. Motivated by the porous nature of the cardiac tissue, in this study we also propose a nonlinear Fickian flux formulated by Taylor expanding the voltage dependent diffusion coefficient up to quadratic terms. A fine tuning of the diffusive parameters is performed a priori to match the conduction velocity of the equivalent cable model. The resulting combined effects are then studied by numerically simulating different stimulation protocols on a one-dimensional cable. Model features are compared in terms of action potential morphology, restitution curves, frequency spectra, and spatio-temporal phase differences. Two-dimensional long-run simulations are finally performed to characterize spiral breakup during sustained fibrillation at different thermal states. Temperature and nonlinear diffusion effects are found to impact the repolarization phase of the action potential wave with non-monotone patterns and to increase the propensity of arrhythmogenesis.
Collapse
Affiliation(s)
- A Gizzi
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - A Loppini
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - R Ruiz-Baier
- Mathematical Institute, University of Oxford, Woodstock Road, OX2 6GG Oxford, United Kingdom
| | - A Ippolito
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - A Camassa
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - A La Camera
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - E Emmi
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - L Di Perna
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - V Garofalo
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - C Cherubini
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| | - S Filippi
- Department of Engineering, University Campus Bio-Medico of Rome, Unit of Nonlinear Physics and Mathematical Modeling, Via A. del Portillo 21, 00128 Rome, Italy
| |
Collapse
|
88
|
Rossi S, Griffith BE. Incorporating inductances in tissue-scale models of cardiac electrophysiology. CHAOS (WOODBURY, N.Y.) 2017; 27:093926. [PMID: 28964127 PMCID: PMC5585078 DOI: 10.1063/1.5000706] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Accepted: 07/17/2017] [Indexed: 06/07/2023]
Abstract
In standard models of cardiac electrophysiology, including the bidomain and monodomain models, local perturbations can propagate at infinite speed. We address this unrealistic property by developing a hyperbolic bidomain model that is based on a generalization of Ohm's law with a Cattaneo-type model for the fluxes. Further, we obtain a hyperbolic monodomain model in the case that the intracellular and extracellular conductivity tensors have the same anisotropy ratio. In one spatial dimension, the hyperbolic monodomain model is equivalent to a cable model that includes axial inductances, and the relaxation times of the Cattaneo fluxes are strictly related to these inductances. A purely linear analysis shows that the inductances are negligible, but models of cardiac electrophysiology are highly nonlinear, and linear predictions may not capture the fully nonlinear dynamics. In fact, contrary to the linear analysis, we show that for simple nonlinear ionic models, an increase in conduction velocity is obtained for small and moderate values of the relaxation time. A similar behavior is also demonstrated with biophysically detailed ionic models. Using the Fenton-Karma model along with a low-order finite element spatial discretization, we numerically analyze differences between the standard monodomain model and the hyperbolic monodomain model. In a simple benchmark test, we show that the propagation of the action potential is strongly influenced by the alignment of the fibers with respect to the mesh in both the parabolic and hyperbolic models when using relatively coarse spatial discretizations. Accurate predictions of the conduction velocity require computational mesh spacings on the order of a single cardiac cell. We also compare the two formulations in the case of spiral break up and atrial fibrillation in an anatomically detailed model of the left atrium, and we examine the effect of intracellular and extracellular inductances on the virtual electrode phenomenon.
Collapse
Affiliation(s)
- Simone Rossi
- Department of Mathematics, University of North Carolina, Chapel Hill, North Carolina 27599, USA
| | - Boyce E Griffith
- Departments of Mathematics and Biomedical Engineering and McAllister Heart Institute, University of North Carolina, Chapel Hill, North Carolina 27599, USA
| |
Collapse
|
89
|
Ferrer-Albero A, Godoy EJ, Lozano M, Martínez-Mateu L, Atienza F, Saiz J, Sebastian R. Non-invasive localization of atrial ectopic beats by using simulated body surface P-wave integral maps. PLoS One 2017; 12:e0181263. [PMID: 28704537 PMCID: PMC5509320 DOI: 10.1371/journal.pone.0181263] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2017] [Accepted: 06/28/2017] [Indexed: 01/22/2023] Open
Abstract
Non-invasive localization of continuous atrial ectopic beats remains a cornerstone for the treatment of atrial arrhythmias. The lack of accurate tools to guide electrophysiologists leads to an increase in the recurrence rate of ablation procedures. Existing approaches are based on the analysis of the P-waves main characteristics and the forward body surface potential maps (BSPMs) or on the inverse estimation of the electric activity of the heart from those BSPMs. These methods have not provided an efficient and systematic tool to localize ectopic triggers. In this work, we propose the use of machine learning techniques to spatially cluster and classify ectopic atrial foci into clearly differentiated atrial regions by using the body surface P-wave integral map (BSPiM) as a biomarker. Our simulated results show that ectopic foci with similar BSPiM naturally cluster into differentiated non-intersected atrial regions and that new patterns could be correctly classified with an accuracy of 97% when considering 2 clusters and 96% for 4 clusters. Our results also suggest that an increase in the number of clusters is feasible at the cost of decreasing accuracy.
Collapse
Affiliation(s)
- Ana Ferrer-Albero
- Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, Valencia, Spain
- * E-mail:
| | - Eduardo J. Godoy
- Computational Multiscale Physiology Lab (CoMMLab), Department of Computer Science, Universitat de Valencia, Valencia, Spain
| | - Miguel Lozano
- Computational Multiscale Physiology Lab (CoMMLab), Department of Computer Science, Universitat de Valencia, Valencia, Spain
| | - Laura Martínez-Mateu
- Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, Valencia, Spain
| | | | - Javier Saiz
- Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, Valencia, Spain
| | - Rafael Sebastian
- Computational Multiscale Physiology Lab (CoMMLab), Department of Computer Science, Universitat de Valencia, Valencia, Spain
| |
Collapse
|
90
|
|
91
|
Costabal FS, Concha FA, Hurtado DE, Kuhl E. The importance of mechano-electrical feedback and inertia in cardiac electromechanics. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING 2017; 320:352-368. [PMID: 29056782 PMCID: PMC5646712 DOI: 10.1016/j.cma.2017.03.015] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
In the past years, a number cardiac electromechanics models have been developed to better understand the excitation-contraction behavior of the heart. However, there is no agreement on whether inertial forces play a role in this system. In this study, we assess the influence of mass in electromechanical simulations, using a fully coupled finite element model. We include the effect of mechano-electrical feedback via stretch activated currents. We compare five different models: electrophysiology, electromechanics, electromechanics with mechano-electrical feedback, electromechanics with mass, and electromechanics with mass and mechano-electrical feedback. We simulate normal conduction to study conduction velocity and spiral waves to study fibrillation. During normal conduction, mass in conjunction with mechano-electrical feedback increased the conduction velocity by 8.12% in comparison to the plain electrophysiology case. During the generation of a spiral wave, mass and mechano-electrical feedback generated secondary wavefronts, which were not present in any other model. These secondary wavefronts were initiated in tensile stretch regions that induced electrical currents. We expect that this study will help the research community to better understand the importance of mechanoelectrical feedback and inertia in cardiac electromechanics.
Collapse
Affiliation(s)
| | - Felipe A Concha
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Daniel E Hurtado
- Department of Structural and Geotechnical Engineering, School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
- Institute for Biological and Medical Engineering, Schools of Engineering, Medicine and Biological Sciences, Pontificia Universidad Catoólica de Chile, Santiago, Chile
| | - Ellen Kuhl
- Departments of Mechanical Engineering, Bioengineering, and Cardiothoracic Surgery, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
92
|
Lange M, Palamara S, Lassila T, Vergara C, Quarteroni A, Frangi AF. Improved hybrid/GPU algorithm for solving cardiac electrophysiology problems on Purkinje networks. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:e2835. [PMID: 27661463 DOI: 10.1002/cnm.2835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Accepted: 09/15/2016] [Indexed: 06/06/2023]
Abstract
Cardiac Purkinje fibers provide an important pathway to the coordinated contraction of the heart. We present a numerical algorithm for the solution of electrophysiology problems across the Purkinje network that is efficient enough to be used in in silico studies on realistic Purkinje networks with physiologically detailed models of ion exchange at the cell membrane. The algorithm is on the basis of operator splitting and is provided with 3 different implementations: pure CPU, hybrid CPU/GPU, and pure GPU. Compared to our previous work, we modify the explicit gap junction term at network bifurcations to improve its mathematical consistency. Due to this improved consistency of the model, we are able to perform an empirical convergence study against analytical solutions. The study verified that all 3 implementations produce equivalent convergence rates, and shows that the algorithm produces equivalent result across different hardware platforms. Finally, we compare the efficiency of all 3 implementations on Purkinje networks of increasing spatial resolution using membrane models of increasing complexity. Both hybrid and pure GPU implementations outperform the pure CPU implementation, but their relative performance difference depends on the size of the Purkinje network and the complexity of the membrane model used.
Collapse
Affiliation(s)
- M Lange
- CISTIB, Department of Electronic and Electrical Engineering, The University of Sheffield, UK
| | - S Palamara
- MOX, Dipartimento di Matematica, Politecnico di Milano, Italy
| | - T Lassila
- CISTIB, Department of Electronic and Electrical Engineering, The University of Sheffield, UK
| | - C Vergara
- MOX, Dipartimento di Matematica, Politecnico di Milano, Italy
| | - A Quarteroni
- CMCS, Mathematics Institute of Computational Science and Engineering, École Polytechnique Fédérale de Lausanne, Switzerland
| | - A F Frangi
- CISTIB, Department of Electronic and Electrical Engineering, The University of Sheffield, UK
| |
Collapse
|
93
|
Mini Electrodes on Ablation Catheters: Valuable Addition or Redundant Information?-Insights from a Computational Study. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2017; 2017:1686290. [PMID: 28553365 PMCID: PMC5434470 DOI: 10.1155/2017/1686290] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 02/02/2017] [Accepted: 02/16/2017] [Indexed: 12/11/2022]
Abstract
Radiofrequency ablation has become a first-line approach for curative therapy of many cardiac arrhythmias. Various existing catheter designs provide high spatial resolution to identify the best spot for performing ablation and to assess lesion formation. However, creation of transmural and nonconducting ablation lesions requires usage of catheters with larger electrodes and improved thermal conductivity, leading to reduced spatial sensitivity. As trade-off, an ablation catheter with integrated mini electrodes was introduced. The additional diagnostic benefit of this catheter is still not clear. In order to solve this issue, we implemented a computational setup with different ablation scenarios. Our in silico results show that peak-to-peak amplitudes of unipolar electrograms from mini electrodes are more suitable to differentiate ablated and nonablated tissue compared to electrograms from the distal ablation electrode. However, in orthogonal mapping position, no significant difference was observed between distal electrode and mini electrodes electrograms in the ablation scenarios. In conclusion, catheters with mini electrodes bring about additional benefit to distinguish ablated tissue from nonablated tissue in parallel position with high spatial resolution. It is feasible to detect conduction gaps in linear lesions with this catheter by evaluating electrogram data from mini electrodes.
Collapse
|
94
|
BeatBox-HPC simulation environment for biophysically and anatomically realistic cardiac electrophysiology. PLoS One 2017; 12:e0172292. [PMID: 28467407 PMCID: PMC5415003 DOI: 10.1371/journal.pone.0172292] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Accepted: 02/02/2017] [Indexed: 01/16/2023] Open
Abstract
The BeatBox simulation environment combines flexible script language user interface with the robust computational tools, in order to setup cardiac electrophysiology in-silico experiments without re-coding at low-level, so that cell excitation, tissue/anatomy models, stimulation protocols may be included into a BeatBox script, and simulation run either sequentially or in parallel (MPI) without re-compilation. BeatBox is a free software written in C language to be run on a Unix-based platform. It provides the whole spectrum of multi scale tissue modelling from 0-dimensional individual cell simulation, 1-dimensional fibre, 2-dimensional sheet and 3-dimensional slab of tissue, up to anatomically realistic whole heart simulations, with run time measurements including cardiac re-entry tip/filament tracing, ECG, local/global samples of any variables, etc. BeatBox solvers, cell, and tissue/anatomy models repositories are extended via robust and flexible interfaces, thus providing an open framework for new developments in the field. In this paper we give an overview of the BeatBox current state, together with a description of the main computational methods and MPI parallelisation approaches.
Collapse
|
95
|
Lenis G, Pilia N, Loewe A, Schulze WHW, Dössel O. Comparison of Baseline Wander Removal Techniques considering the Preservation of ST Changes in the Ischemic ECG: A Simulation Study. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2017; 2017:9295029. [PMID: 28373893 PMCID: PMC5361052 DOI: 10.1155/2017/9295029] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 02/10/2017] [Accepted: 02/19/2017] [Indexed: 11/25/2022]
Abstract
The most important ECG marker for the diagnosis of ischemia or infarction is a change in the ST segment. Baseline wander is a typical artifact that corrupts the recorded ECG and can hinder the correct diagnosis of such diseases. For the purpose of finding the best suited filter for the removal of baseline wander, the ground truth about the ST change prior to the corrupting artifact and the subsequent filtering process is needed. In order to create the desired reference, we used a large simulation study that allowed us to represent the ischemic heart at a multiscale level from the cardiac myocyte to the surface ECG. We also created a realistic model of baseline wander to evaluate five filtering techniques commonly used in literature. In the simulation study, we included a total of 5.5 million signals coming from 765 electrophysiological setups. We found that the best performing method was the wavelet-based baseline cancellation. However, for medical applications, the Butterworth high-pass filter is the better choice because it is computationally cheap and almost as accurate. Even though all methods modify the ST segment up to some extent, they were all proved to be better than leaving baseline wander unfiltered.
Collapse
Affiliation(s)
- Gustavo Lenis
- Karlsruhe Institute of Technology (KIT), Institute of Biomedical Engineering (IBT), Fritz-Haber-Weg 1, 76131 Karlsruhe, Germany
| | - Nicolas Pilia
- Karlsruhe Institute of Technology (KIT), Institute of Biomedical Engineering (IBT), Fritz-Haber-Weg 1, 76131 Karlsruhe, Germany
| | - Axel Loewe
- Karlsruhe Institute of Technology (KIT), Institute of Biomedical Engineering (IBT), Fritz-Haber-Weg 1, 76131 Karlsruhe, Germany
| | | | - Olaf Dössel
- Karlsruhe Institute of Technology (KIT), Institute of Biomedical Engineering (IBT), Fritz-Haber-Weg 1, 76131 Karlsruhe, Germany
| |
Collapse
|
96
|
Niederer SA, Smith NP. Using physiologically based models for clinical translation: predictive modelling, data interpretation or something in-between? J Physiol 2016; 594:6849-6863. [PMID: 27121495 PMCID: PMC5134392 DOI: 10.1113/jp272003] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2015] [Accepted: 03/13/2016] [Indexed: 02/02/2023] Open
Abstract
Heart disease continues to be a significant clinical problem in Western society. Predictive models and simulations that integrate physiological understanding with patient information derived from clinical data have huge potential to contribute to improving our understanding of both the progression and treatment of heart disease. In particular they provide the potential to improve patient selection and optimisation of cardiovascular interventions across a range of pathologies. Currently a significant proportion of this potential is still to be realised. In this paper we discuss the opportunities and challenges associated with this realisation. Reviewing the successful elements of model translation for biophysically based models and the emerging supporting technologies, we propose three distinct modes of clinical translation. Finally we outline the challenges ahead that will be fundamental to overcome if the ultimate goal of fully personalised clinical cardiac care is to be achieved.
Collapse
Affiliation(s)
- Steven A. Niederer
- Department of Biomedical Engineering and Imaging SciencesSt Thomas’ HospitalKing's College LondonThe Rayne Institute4th Floor Lambeth WingLondonSE1 7EHUK
| | - Nic P. Smith
- Department of Biomedical Engineering and Imaging SciencesSt Thomas’ HospitalKing's College LondonThe Rayne Institute4th Floor Lambeth WingLondonSE1 7EHUK
- Engineering School Block 1University of AucklandLevel 5, 20 Symonds StreetAuckland101New Zealand
| |
Collapse
|
97
|
Pezzuto S, Hake J, Sundnes J. Space-discretization error analysis and stabilization schemes for conduction velocity in cardiac electrophysiology. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2016; 32:e02762. [PMID: 26685879 DOI: 10.1002/cnm.2762] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 11/24/2015] [Accepted: 11/29/2015] [Indexed: 06/05/2023]
Abstract
In cardiac electrophysiology, the propagation of the action potential may be described by a set of reaction-diffusion equations known as the bidomain model. The shape of the solution is determined by a balance of a strong reaction and a relatively weak diffusion, which leads to steep variations in space and time. From a numerical point of view, the sharp spatial gradients may be seen as particularly problematic, because computational grid resolution on the order of 0.1 mm or less is required, yielding considerable computational efforts on human geometries. In this paper, we discuss a number of well-known numerical schemes for the bidomain equation and show how the quality of the solution is affected by the spatial discretization. In particular, we study in detail the effect of discretization on the conduction velocity (CV), which is an important quantity from a physiological point of view. We show that commonly applied finite element techniques tend to overestimate the CV on coarse grids, while it tends to be underestimated by finite difference schemes. Furthermore, the choice of interpolation and discretization scheme for the nonlinear reaction term has a strong impact on the CV. Finally, we exploit the results of the error analysis to propose improved numerical methods, including a stabilized scheme that tends to correct the CV on coarse grids but converges to the correct solution as the grid is refined. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- S Pezzuto
- Center for Computational Medicine in Cardiology, Institute of Computational Science, Università della Svizzera italiana, Lugano, 6904, Switzerland.
- Simula Research Laboratory, Fornebu, 1364, Norway.
| | - J Hake
- Simula Research Laboratory, Fornebu, 1364, Norway
| | - J Sundnes
- Simula Research Laboratory, Fornebu, 1364, Norway
- Department of Informatics, University of Oslo, 0316, Oslo
| |
Collapse
|
98
|
Parametrization of activation based cardiac electrophysiology models using bidomain model simulations. CURRENT DIRECTIONS IN BIOMEDICAL ENGINEERING 2016. [DOI: 10.1515/cdbme-2016-0135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Abstract
Eikonal models are useful to compute approximate solutions of cardiac excitation propagation in a computationally efficient way. In this work the underlying conduction velocities for different cell types were computed solving the classical bidomain model equations for planar wavefront propagation. It was further investigated how changes in the conductivity tensors within the bidomain model analytically correspond to changes in the conduction velocity. The error in the presence of local front curvature for the derived eikonal model parametrization were analyzed. The conduction velocity simulated based on the bidomain model was overestimated by a maximum of 10%.
Collapse
|
99
|
Sahli Costabal F, Hurtado DE, Kuhl E. Generating Purkinje networks in the human heart. J Biomech 2016; 49:2455-65. [PMID: 26748729 PMCID: PMC4917481 DOI: 10.1016/j.jbiomech.2015.12.025] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Accepted: 12/07/2015] [Indexed: 10/22/2022]
Abstract
The Purkinje network is an integral part of the excitation system in the human heart. Yet, to date, there is no in vivo imaging technique to accurately reconstruct its geometry and structure. Computational modeling of the Purkinje network is increasingly recognized as an alternative strategy to visualize, simulate, and understand the role of the Purkinje system. However, most computational models either have to be generated manually, or fail to smoothly cover the irregular surfaces inside the left and right ventricles. Here we present a new algorithm to reliably create robust Purkinje networks within the human heart. We made the source code of this algorithm freely available online. Using Monte Carlo simulations, we demonstrate that the fractal tree algorithm with our new projection method generates denser and more compact Purkinje networks than previous approaches on irregular surfaces. Under similar conditions, our algorithm generates a network with 1219±61 branches, three times more than a conventional algorithm with 419±107 branches. With a coverage of 11±3mm, the surface density of our new Purkije network is twice as dense as the conventional network with 22±7mm. To demonstrate the importance of a dense Purkinje network in cardiac electrophysiology, we simulated three cases of excitation: with our new Purkinje network, with left-sided Purkinje network, and without Purkinje network. Simulations with our new Purkinje network predicted more realistic activation sequences and activation times than simulations without. Six-lead electrocardiograms of the three case studies agreed with the clinical electrocardiograms under physiological conditions, under pathological conditions of right bundle branch block, and under pathological conditions of trifascicular block. Taken together, our results underpin the importance of the Purkinje network in realistic human heart simulations. Human heart modeling has the potential to support the design of personalized strategies for single- or bi-ventricular pacing, radiofrequency ablation, and cardiac defibrillation with the common goal to restore a normal heart rhythm.
Collapse
Affiliation(s)
| | - Daniel E Hurtado
- Department of Structural and Geotechnical Engineering and Institute of Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Ellen Kuhl
- Departments of Mechanical Engineering, Bioengineering, and Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
| |
Collapse
|
100
|
Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation. PLoS Comput Biol 2016; 12:e1004968. [PMID: 27336310 PMCID: PMC4919062 DOI: 10.1371/journal.pcbi.1004968] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Accepted: 05/05/2016] [Indexed: 02/07/2023] Open
Abstract
Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is derived by modifying a previously validated electrophysiology model for a healthy rabbit heart. Specifically, in accordance with the heart failure literature, we modified the cell EP by changing both membrane currents and calcium handling. At the tissue level, we modeled the increased gap junction lateralization and lower conduction velocity due to downregulation of Connexin 43. At the biventricular level, we reduced the apex-to-base and transmural gradients of action potential duration (APD). The failing cell model was first validated by reproducing the longer action potential, slower and lower calcium transient, and earlier alternans characteristic of heart failure EP. Subsequently, we compared the electrical wave propagation in one dimensional cables of healthy and failing cells. The validated cell model was then used to simulate the EP of heart failure in an anatomically accurate biventricular rabbit model. As pacing cycle length decreases, both the normal and failing heart develop T-wave alternans, but only the failing heart shows QRS alternans (although moderate) at rapid pacing. Moreover, T-wave alternans is significantly more pronounced in the failing heart. At rapid pacing, APD maps show areas of conduction block in the failing heart. Finally, accelerated pacing initiated wave reentry and breakup in the failing heart. Further, the onset of VF was not observed with an upregulation of SERCA, a potential drug therapy, using the same protocol. The changes introduced at the cell and tissue level have increased the failing heart’s susceptibility to dynamic instabilities and arrhythmias under rapid pacing. However, the observed increase in arrhythmogenic potential is not due to a steepening of the restitution curve (not present in our model), but rather to a novel blocking mechanism. Ventricular fibrillation (VF) is one of the leading causes of sudden death. During VF, the electrical wave of activation in the heart breaks up chaotically. Consequently, the heart is unable to contract synchronously and pump blood to the rest of the body. In our work we formulate and validate a model of heart failure (HF) that allows us to evaluate the arrhythmogenic potential of individual and combined electrophysiological changes. In diagnostic cardiology, the electrocardiogram (ECG) is one of the most commonly used tools for detecting abnormalities in the heart electrophysiology. One of our goals is to use our numerical model to link changes at the cellular and tissue level in a failing heart to a numerically computed ECG. This allows us to characterize the precursor to and the risk of VF. In order to understand the mechanisms underlying VF in HF, we design a test that simulates a HF patient performing physical exercise. We show that under fast heart rates with changes in pacing, HF patients are more prone to VF due to a new conduction blocking mechanism. In the long term, our mathematical model is suitable for investigating the effect of drug therapies in HF.
Collapse
|