51
|
Saengsuwan J, Ruangsuphaphichat A, Brockmann L, Sirasaporn P, Manimmanakorn N, Hunt KJ. Diurnal variation of heart rate variability in individuals with spinal cord injury. Biomed Eng Online 2024; 23:58. [PMID: 38902756 PMCID: PMC11188279 DOI: 10.1186/s12938-024-01256-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Accepted: 06/12/2024] [Indexed: 06/22/2024] Open
Abstract
BACKGROUND Heart rate variability (HRV) may provide objective information about cardiogenic autonomic balance in individuals with spinal cord injury (SCI). The aim of this study was to characterize the diurnal variation of HRV in individuals with SCI at lesion level T6 and above and lesion level below T6. METHODS This was a retrospective analysis of a prior cross-sectional study. Individuals with chronic SCI underwent 24 h recording of the time between consecutive R waves (RR interval) to derive parameters of HRV as follows: standard deviation of all normal-to-normal R-R intervals (SDNN) and square root of the mean of the squared differences between successive R-R intervals (RMSSD) (time domain); and high frequency power (HF), low-frequency power (LF), very low frequency power (VLF), ultra-low frequency power (ULF) and total power (TP) (frequency domain). Changes in the magnitude of HRV outcomes over the 24 h period were investigated using a novel multi-component cosinor model constrained to the form of a three-harmonic Fourier series. RESULTS Participants were grouped as lesion level T6 and above (n = 22) or below T6 (n = 36). Most of them were male (n = 40, 69%) and the median age (interquartile range) was 50.5 (28) years. Both groups exhibited similar diurnal patterns in most HRV metrics. The lowest values occurred in the late afternoon (4-6 pm) and gradually increased, peaking around midnight to early morning (1-6 am). Exceptions included RMSSD, which peaked before midnight, and ULF, which showed a double peak pattern that peaked from 11 am to 1 pm and 4-6 am in participants with lesion level at T6 and above. The HRV values in participants with lesion level T6 and above were generally lower than participants with lesion level below T6, except for peak values of RMSSD, HF and LF. CONCLUSION This study demonstrated substantial diurnal variation of HRV in participants with SCI in both groups of participants. In clinical and research settings, diurnal variations in HRV must be taken into consideration.
Collapse
Affiliation(s)
- Jittima Saengsuwan
- Department of Rehabilitation Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
- The Laboratory for Rehabilitation Engineering, Institute for Human Centred Engineering, Bern University of Applied Sciences, Biel, Switzerland.
| | | | - Lars Brockmann
- The Laboratory for Rehabilitation Engineering, Institute for Human Centred Engineering, Bern University of Applied Sciences, Biel, Switzerland
| | - Patpiya Sirasaporn
- Department of Rehabilitation Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
| | - Nuttaset Manimmanakorn
- Department of Rehabilitation Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
| | - Kenneth J Hunt
- The Laboratory for Rehabilitation Engineering, Institute for Human Centred Engineering, Bern University of Applied Sciences, Biel, Switzerland
| |
Collapse
|
52
|
Alessandria M, Angilletta S, Pivetta I, Annone B, Cravanzola S, De Giorgio A. 4-week stretching program after submaximal strength exercise affects performance but not heart rate variability and lactate clearance. An exploratory study. Front Sports Act Living 2024; 6:1424756. [PMID: 38957877 PMCID: PMC11217188 DOI: 10.3389/fspor.2024.1424756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Accepted: 05/31/2024] [Indexed: 07/04/2024] Open
Abstract
Previous research has demonstrated that stretching can enhance athletic performance and induce cardiovascular adaptations. This study aims to assess whether a 4-week preventative stretching routine can enhance heart rate variability and heart rate recovery, faster blood lactate clearance, and improve performance following submaximal strength exercises. Twenty-four healthy adults were recruited and randomly allocated to either the experimental group or the control group. Both groups engaged in submaximal strength exercises (5 sets to voluntary failure at 60% of 1RM) comprising bench press and back squat exercises under baseline conditions and after stretching protocol. The experimental group followed the Stretching Protocol, while the control group adhered to their regular training routine. ANOVA analysis revealed a significant pre-post interaction effect between groups in the variable of squat repetitions, although no notable pre- or post-differences were observed in heart rate variability, heart rate recovery, blood lactate concentration, or bench repetitions in either group. A 4-week preventative stretching program does not appear adequate to enhance lactate clearance and cardiovascular adaptation after submaximal strength exercises in resistance-trained individuals compared to the control group. However, it is plausible that such a stretching routine may mitigate muscle fatigue, though further investigation is warranted to substantiate this hypothesis.
Collapse
Affiliation(s)
- M. Alessandria
- Department of Life Sciences and Systems Biology, University of Turin, Turin, Italy
| | - S. Angilletta
- A.S.D. “SportTiVà?”, Turin, Italy
- Faculty of Psychology, eCampus University, Novedrate, Italy
| | - I. Pivetta
- Department of Life Sciences and Systems Biology, University of Turin, Turin, Italy
| | - B. Annone
- Department of Life Sciences and Systems Biology, University of Turin, Turin, Italy
| | - S. Cravanzola
- Department of Life Sciences and Systems Biology, University of Turin, Turin, Italy
| | - A. De Giorgio
- A.S.D. “SportTiVà?”, Turin, Italy
- Faculty of Psychology, eCampus University, Novedrate, Italy
| |
Collapse
|
53
|
Zhang Y, Hui Z, Qi W, Zhang J, Wang M, Zhu D. Clinical study on the safety and feasibility of AiWalker-K for lower limbs exercise rehabilitation in children with cerebral palsy. PLoS One 2024; 19:e0303517. [PMID: 38776339 PMCID: PMC11111022 DOI: 10.1371/journal.pone.0303517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 04/24/2024] [Indexed: 05/24/2024] Open
Abstract
BACKGROUND Robotic-assisted gait training (RAGT) devices are effective for children with cerebral palsy (CP). Many RAGT devices have been created and put into clinical rehabilitation treatment. Therefore, we aimed to investigate the safety and feasibility of a new RAGT for children with CP. METHODS This study is a cross-over design with 23 subjects randomly divided into two groups. The occurrence of adverse events and changes in heart rate and blood pressure were recorded during each AiWalker-K training. Additionally, Gross Motor Function Measure-88 (GMFM-88), Pediatric Balance Scale (PBS), 6 Minutes Walking Test (6MWT), Physiological Cost Index, and Edinburgh Visual Gait Score (EVGS) were used to assess treatment, period, carry-over, and follow-up effects in this study. RESULTS Adverse events included joint pain, skin pain, and injury. Heart rate and blood pressure were higher with the AiWalker-K compared to the rest (P < 0.05), but remained within safe ranges. After combined treatment with AiWalker-K and routine rehabilitation treatment, significant improvements in 6MWT, GMFM-88 D and E, PBS, and EVGS were observed compared to routine rehabilitation treatment alone (P < 0.05). CONCLUSIONS Under the guidance of experienced medical personnel, AiWalker-K can be used for rehabilitation in children with CP.
Collapse
Affiliation(s)
- Yi Zhang
- Department of Rehabilitation Medicine, the Third Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Zhichong Hui
- Department of Rehabilitation Medicine, the Third Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Weihang Qi
- Department of Rehabilitation Medicine, the Third Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Jiamei Zhang
- Department of Rehabilitation Medicine, the Third Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Mingmei Wang
- Department of Rehabilitation Medicine, the Third Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Dengna Zhu
- Department of Rehabilitation Medicine, the Third Affiliated Hospital of Zhengzhou University, Zhengzhou, China
- Henan Key Laboratory of Child Brain Injury and Henan Pediatric Clinical Research Center, Institute of Neuroscience and Third Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| |
Collapse
|
54
|
Fennell CRJ, Mauger AR, Hopker JG. Inter-day reliability of heart rate complexity and variability metrics in healthy highly active younger and older adults. Eur J Appl Physiol 2024; 124:1409-1424. [PMID: 38054978 PMCID: PMC11055755 DOI: 10.1007/s00421-023-05373-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 11/11/2023] [Indexed: 12/07/2023]
Abstract
PURPOSE To investigate the inter-day reliability of time-domain, frequency-domain, and nonlinear HRV metrics in healthy highly active younger and older adults. The study also assessed the effect of age on the HRV metrics. METHODS Forty-four older adults (34 M, 10F; 59 ± 5 years;V ˙ O 2peak = 40.9 ± 7.6 ml kg-1 min-1) and twenty-two younger adults (16 M, 6F; 22 ± 4 years;V ˙ O 2peak = 47.2 ± 12.8 ml kg-1 min-1) attended the laboratory. Visit one assessed aerobic fitness through an exercise test. In visits two and three, participants completed a 30-min supine RR interval measurement to derive the HRV metrics. RESULTS The younger group (YG) and older group (OG) demonstrated poor to good day-to-day relative and absolute reliability for all HRV metrics (OG, ICCs = 0.33 to 0.69 and between day CVs = 3.8 to 29.2%; YG, ICCs = 0.37 to 0.93 and between day CVs = 3.5 to 36.5%). There was a significant reduction in ApEn (P < 0.001), SampEn (P = 0.031), RMSSD (P < 0.001), SDNN (P < 0.001), LF power (P < 0.001) and HF power (P < 0.001), HRV metrics with ageing. There was no significant effect of age the complexity metrics DFA α1 (P = 0.107), α2 (P = 0.147) and CI-8 (P = 0.493). CONCLUSION HRV metrics are reproducible between days in both healthy highly active younger and older adults. There is a decline in linear and nonlinear HRV metrics with age, albeit there being no age-related change in the nonlinear metrics, DFA α1, α2 and CI-8.
Collapse
Affiliation(s)
- Christopher R J Fennell
- School of Sport and Exercise Sciences, University of Kent, Chipperfield Building, Canterbury, Kent, CT2 7PE, UK.
| | - Alexis R Mauger
- School of Sport and Exercise Sciences, University of Kent, Chipperfield Building, Canterbury, Kent, CT2 7PE, UK
| | - James G Hopker
- School of Sport and Exercise Sciences, University of Kent, Chipperfield Building, Canterbury, Kent, CT2 7PE, UK
| |
Collapse
|
55
|
Huang Z, Bai H, Yang Z, Zhang J, Wang P, Wang X, Zhang L. Bridging childhood to adulthood: the impact of early life stress on acute stress responses. Front Psychiatry 2024; 15:1391653. [PMID: 38699445 PMCID: PMC11064211 DOI: 10.3389/fpsyt.2024.1391653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Accepted: 03/28/2024] [Indexed: 05/05/2024] Open
Abstract
Background Childhood trauma exerts enduring impacts on the physical and psychological well-being of individuals in adulthood, influencing their daily functioning. This study aims to investigate the impact of childhood trauma on stress recovery in adults, concentrating on heart rate variations during acute stress exposure. Methods A cohort of 126 participants completed the Childhood Trauma Questionnaire (CTQ) and underwent the Trier Social Stress Test (TSST) to elicit acute stress, with continuous heart rate (HR) monitoring for stress recovery assessment. Results The results revealed a negative correlation between childhood trauma and stress recovery, prominently observed in instances of emotional neglect and abuse. Individuals with heightened childhood trauma exhibited protracted stress recovery following acute stress exposure. Conclusion Childhood traumatic experiences were associated with the recovery from acute stress, as indicated by heart rate indices. These findings contribute to the foundational framework for psychological interventions tailored to individuals with a history of childhood trauma.
Collapse
Affiliation(s)
- Zheng Huang
- Key Laboratory of Behavioral Science, Institute of Psychology, Chinese Academy of Sciences, Beijing, China
- Department of Psychology, University of Chinese Academy of Sciences, Beijing, China
| | - Huizhi Bai
- Key Laboratory of Modern Teaching Technology, Ministry of Education, Shaanxi Normal University, Xi’an, China
| | - Ziyu Yang
- Key Laboratory of Behavioral Science, Institute of Psychology, Chinese Academy of Sciences, Beijing, China
| | - Jingyu Zhang
- Key Laboratory of Behavioral Science, Institute of Psychology, Chinese Academy of Sciences, Beijing, China
- Department of Psychology, University of Chinese Academy of Sciences, Beijing, China
| | - Peishan Wang
- Key Laboratory of Behavioral Science, Institute of Psychology, Chinese Academy of Sciences, Beijing, China
- Department of Psychology, University of Chinese Academy of Sciences, Beijing, China
| | - Xiaoyu Wang
- Key Laboratory of Behavioral Science, Institute of Psychology, Chinese Academy of Sciences, Beijing, China
- Department of Psychology, University of Chinese Academy of Sciences, Beijing, China
| | - Liang Zhang
- Key Laboratory of Behavioral Science, Institute of Psychology, Chinese Academy of Sciences, Beijing, China
- Department of Psychology, University of Chinese Academy of Sciences, Beijing, China
| |
Collapse
|
56
|
Breunissen EHW, Groenveld TD, Garms L, Bonnes JL, van Goor H, Damman P. Virtual reality to reduce periprocedural anxiety during invasive coronary angiography: rationale and design of the VR InCard trial. Open Heart 2024; 11:e002628. [PMID: 38569670 PMCID: PMC10989163 DOI: 10.1136/openhrt-2024-002628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 03/24/2024] [Indexed: 04/05/2024] Open
Abstract
INTRODUCTION Patients undergoing invasive coronary angiography (ICA) experience anxiety due to various reasons. Procedural anxiety can lead to physiological and psychological complications, compromising patient comfort and overall procedural outcomes. Benzodiazepines are commonly used to reduce periprocedural anxiety, although the effect is modest. Virtual reality (VR) is a promising non-pharmacological intervention to reduce anxiety in patients undergoing ICA. METHODS AND ANALYSIS A single-centre open-label randomised controlled trial is conducted assessing the effectiveness of add-on VR therapy on anxiety in 100 patients undergoing ICA and experiencing anxiety in a periprocedural setting. The primary outcome is the Numeric Rating Scale (NRS) anxiety score measured just before obtaining arterial access. Secondary outcomes include postarterial puncture and postprocedural anxiety, patient-reported outcome measures (PROMs) of anxiety and physiological measurements associated with anxiety. The NRS anxiety level and physiological measurements are assessed five times during the procedure. The PROM State-Trait Anxiety Inventory and Perceived Stress Scale are completed preprocedure, and the PROM STAI and the Igroup Presence Questionnaire are performed postprocedure. ETHICS AND DISSEMINATION The protocol of this study has been approved by the Research Ethics Committee of the Radboud University Medical Centre, the Netherlands (CMO Arnhem-Nijmegen, 2023-16586). Informed consent is obtained from all patients. The trial is conducted according to the principles of the Helsinki Declaration and in accordance with Dutch guidelines, regulations, and acts (Medical Research involving Human Subjects Act, WMO). REGISTRATION DETAILS Trial registration number: NCT06215456.
Collapse
Affiliation(s)
| | | | - Linda Garms
- Surgery, Radboudumc, Nijmegen, Gelderland, The Netherlands
| | - Judith L Bonnes
- Cardiology, Radboudumc, Nijmegen, Gelderland, The Netherlands
| | - Harry van Goor
- Surgery, Radboudumc, Nijmegen, Gelderland, The Netherlands
| | - Peter Damman
- Cardiology, Radboudumc, Nijmegen, Gelderland, The Netherlands
| |
Collapse
|
57
|
Kanniainen M, Pukkila T, Kuisma J, Molkkari M, Lajunen K, Räsänen E. Estimation of physiological exercise thresholds based on dynamical correlation properties of heart rate variability. Front Physiol 2023; 14:1299104. [PMID: 38179139 PMCID: PMC10765723 DOI: 10.3389/fphys.2023.1299104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 11/30/2023] [Indexed: 01/06/2024] Open
Abstract
Aerobic and anaerobic thresholds of the three-zone exercise model are often used to evaluate the exercise intensity and optimize the training load. Conventionally, these thresholds are derived from the respiratory gas exchange or blood lactate concentration measurements. Here, we introduce and validate a computational method based on the RR interval (RRI) dynamics of the heart rate (HR) measurement, which enables a simple, yet reasonably accurate estimation of both metabolic thresholds. The method utilizes a newly developed dynamical detrended fluctuation analysis (DDFA) to assess the real-time changes in the dynamical correlations of the RR intervals during exercise. The training intensity is shown to be in direct correspondence with the time- and scale-dependent changes in the DDFA scaling exponent. These changes are further used in the definition of an individual measure to estimate the aerobic and anaerobic threshold. The results for 15 volunteers who participated in a cyclo-ergometer test are compared to the benchmark lactate thresholds, as well as to the ventilatory threshods and alternative HR-based estimates based on the maximal HR and the conventional detrended fluctuation analysis (DFA). Our method provides the best overall agreement with the lactate thresholds and provides a promising, cost-effective alternative to conventional protocols, which could be easily integrated in wearable devices. However, detailed statistical analysis reveals the particular strengths and weaknessess of each method with respect to the agreement and consistency with the thresholds-thus underlining the need for further studies with more data.
Collapse
Affiliation(s)
- Matias Kanniainen
- Computational Physics Laboratory, Tampere University, Tampere, Finland
| | - Teemu Pukkila
- Computational Physics Laboratory, Tampere University, Tampere, Finland
| | - Joonas Kuisma
- Computational Physics Laboratory, Tampere University, Tampere, Finland
| | - Matti Molkkari
- Computational Physics Laboratory, Tampere University, Tampere, Finland
| | | | - Esa Räsänen
- Computational Physics Laboratory, Tampere University, Tampere, Finland
| |
Collapse
|
58
|
Koerber D, Khan S, Shamsheri T, Kirubarajan A, Mehta S. Accuracy of Heart Rate Measurement with Wrist-Worn Wearable Devices in Various Skin Tones: a Systematic Review. J Racial Ethn Health Disparities 2023; 10:2676-2684. [PMID: 36376641 PMCID: PMC9662769 DOI: 10.1007/s40615-022-01446-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 10/21/2022] [Accepted: 11/01/2022] [Indexed: 11/16/2022]
Abstract
BACKGROUND Wearable consumer technology allows for the collection of a growing amount of personal health data. Through the analysis of reflected LED light on the skin, heart rate measurement and arrhythmia detection can be performed. Given that melanin alters skin light absorption, this study seeks to summarize the accuracy of cardiac data from wrist-worn wearable devices for participants of varying skin tones. METHODS We conducted a systematic review, searching Embase, MEDLINE, CINAHL, and Cochrane for original studies that stratified heart rate and rhythm data for consumer wearable technology according to participant race and/or skin tone. RESULTS A total of 10 studies involving 469 participants met inclusion criteria. The frequency-weighted Fitzpatrick score for skin tone was reported in six studies (n = 293), with a mean participant score of 3.5 (range 1-6). Overall, four of the ten studies reported a significant reduction in accuracy of heart rate measurement with wearable devices in darker-skinned individuals, compared to participants with lighter skin tones. Four studies noted no effect of user skin tone on accuracy. The remaining two studies showed mixed results. CONCLUSIONS Preliminary evidence is inconclusive, but some studies suggest that wearable devices may be less accurate for detecting heart rate in participants with darker skin tones. Higher quality evidence is necessary, with larger sample sizes and more objective stratification of participants by skin tone, in order to characterize potential racial bias in consumer devices.
Collapse
Affiliation(s)
- Daniel Koerber
- Faculty of Medicine, University of Toronto, Toronto, Canada
| | - Shawn Khan
- Faculty of Medicine, University of Toronto, Toronto, Canada
| | - Tahmina Shamsheri
- Department of Interdisciplinary Studies, McMaster University, Hamilton, Canada
| | - Abirami Kirubarajan
- Faculty of Medicine, University of Toronto, Toronto, Canada
- Institute of Health Policy Management and Evaluation, University of Toronto, Toronto, Canada
| | - Sangeeta Mehta
- Faculty of Medicine, University of Toronto, Toronto, Canada.
- Department of Medicine, Interdepartmental Division of Critical Care Medicine, Sinai Health System, University of Toronto, Toronto, Canada.
- Mount Sinai Hospital, 600 University Ave, Suite 18-216, Toronto, ON, Canada.
| |
Collapse
|
59
|
Vondrasek JD, Riemann BL, Grosicki GJ, Flatt AA. Validity and Efficacy of the Elite HRV Smartphone Application during Slow-Paced Breathing. SENSORS (BASEL, SWITZERLAND) 2023; 23:9496. [PMID: 38067869 PMCID: PMC10708620 DOI: 10.3390/s23239496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/25/2023] [Accepted: 11/23/2023] [Indexed: 12/18/2023]
Abstract
Slow-paced breathing is a clinical intervention used to increase heart rate variability (HRV). The practice is made more accessible via cost-free smartphone applications like Elite HRV. We investigated whether Elite HRV can accurately measure and augment HRV via its slow-paced breathing feature. Twenty young adults completed one counterbalanced cross-over protocol involving 10 min each of supine spontaneous (SPONT) and paced (PACED; 6 breaths·min-1) breathing while RR intervals were simultaneously recorded via a Polar H10 paired with Elite HRV and reference electrocardiography (ECG). Individual differences in HRV between devices were predominately skewed, reflecting a tendency for Elite HRV to underestimate ECG-derived values. Skewness was typically driven by a limited number of outliers as median bias values were ≤1.3 ms and relative agreement was ≥very large for time-domain parameters. Despite no significant bias and ≥large relative agreement for frequency-domain parameters, limits of agreement (LOAs) were excessively wide and tended to be wider during PACED for all HRV parameters. PACED significantly increased low-frequency power (LF) for Elite HRV and ECG, and between-condition differences showed very large relative agreement. Elite HRV-guided slow-paced breathing effectively increased LF values, but it demonstrated greater precision during SPONT and in computing time-domain HRV.
Collapse
Affiliation(s)
- Joseph D. Vondrasek
- Biodynamics and Human Performance Center, Department of Health Sciences and Kinesiology, Georgia Southern University (Armstrong), 11935 Abercorn St., Savannah, GA 31419, USA; (B.L.R.); (G.J.G.); (A.A.F.)
| | | | | | | |
Collapse
|
60
|
Thrower A, Barone Gibbs B, Alansare A, Sherman S, Davis K. Blood pressure and heart rate variability responses following an acute bout of vinyasa yoga and a prolonged seated control: A randomized crossover trial. PLoS One 2023; 18:e0294945. [PMID: 38015939 PMCID: PMC10684087 DOI: 10.1371/journal.pone.0294945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 11/11/2023] [Indexed: 11/30/2023] Open
Abstract
Vinyasa yoga is moderate-intensity physical activity, yet physiological responses are poorly characterized. The purpose of this study was to examine the effect of a vinyasa yoga session on autonomic/cardiovascular functioning in healthy adults. A randomized crossover design took place at the Physical Activity and Weight Management laboratory (Pittsburgh, PA; n = 18), and included two experimental conditions: 60 minutes of vinyasa yoga or a seated control, and measurements were taken at baseline, 5-minutes, and 65-minute post-conditions. The primary cardiovascular-related outcomes of this study included blood pressure (BP), heart rate (HR), and HR variability (HRV) measures [natural log transformed (ln) standard deviation of normal-to-normal R-R intervals (SDNN), root mean square of successive differences (RMSSD), high frequency (HF), and low frequency to high frequency ratio (LF/HF ratio)]. Linear mixed effects models were used for data analyses. Systolic BP was 8.14 mmHg lower at 5 minutes post yoga (p<0.001) but was not different 65 minutes post, compared to the control. HR was higher at 5- and 65-minutes post yoga compared to the control (10.49/4.70 bpm, respectively, both p<0.01). HRV was lower (worse) at 5 and 65 minutes post for lnSDNN, lnRMSSD, and lnHF (all p<0.01). LF/HF ratio was higher (worse) at 5 minutes post yoga compared to the control (difference = +0.38, p = 0.025), but not different at 65 minutes post between conditions. Compared to prolonged sitting, vinyasa yoga had variable effects on post-session autonomic function including favorable BP responses and unfavorable HR and HRV responses, further investigation is warranted.
Collapse
Affiliation(s)
- Alexis Thrower
- Department of Pathophysiology, Rehabilitation, and Performance, West Virginia University, Morgantown, West Virginia, United States of America
| | - Bethany Barone Gibbs
- Department of Epidemiology and Biostatistics, West Virginia University, Morgantown, West Virginia, United States of America
| | - Abdullah Alansare
- Department of Exercise Physiology, King Saud University, Riyadh, Saudi Arabia
| | - Sally Sherman
- Department of Health and Human Development, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America
| | - Kelliann Davis
- Department of Health and Human Development, University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America
| |
Collapse
|
61
|
Ammar A, Boujelbane MA, Simak ML, Fraile-Fuente I, Trabelsi K, Bouaziz B, Rizzi N, Schöllhorn WI. Exploratory study of the acute and mid-term effects of using a novel dynamic meeting environment (Aeris ®) on cognitive performance and neurophysiological responses. Front Hum Neurosci 2023; 17:1282728. [PMID: 38077188 PMCID: PMC10702232 DOI: 10.3389/fnhum.2023.1282728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 10/30/2023] [Indexed: 02/03/2025] Open
Abstract
The purpose of the present study was to assess the acute and mid-term effects of the dynamic aeris®-meeting- environment on brain activity, cognitive performance, heart rate variability (HRV), sleepiness, mental workload (EEG-MWI), as well as local experienced discomfort (LED) in healthy adults. Twenty-four healthy adults (16 females, age: 25.2 ± 3.1 years old) were randomly assigned to either the control (i.e., conventional meeting environment, CG) or experimental (Aeris® dynamic meeting-environment, DG) group with a 1:1 allocation. Participants reported to the laboratory on two test sessions separated by a 2-week intervention period (5 meetings of 90 min each week). Spontaneous resting EEG and HRV activities, as well as attentional (D2-R test) and vigilance (PVT) cognitive performances, sleepiness perceptions, and EEG-MWI, were recorded at the beginning of each test session and immediately following the 90-min meeting. The LED was measured pre- and post-intervention. The changes (Δ) from pre- to post-90 min meeting and from pre- to post- intervention were computed to further examine the acute and mid-term effects, respectively. Compared to the CG, the DG showed higher Δ (pre-post 90 min-meeting) in fronto-central beta (z = -2.41, p = 0.016, d = 1.10) and gamma (z = -2.34, p = 0.019, d = 0.94) frequencies at post-intervention. From pre- to post-intervention, only the DG group showed a significant increase in fronto-central gamma response (Δ) to the meeting session (z = -2.09, p = 0.04, d = 1.08). The acute use of the Aeris®-meeting-environment during the 90-min meeting session seems to be supportive for (i) maintaining vigilance performance, as evidenced by the significant increase in N-lapses from pre- to post-90 min session only in the CG (p = 0.04, d = 0.99, Δ = 2.5 ± 3 lapses), and (ii) improving alertness, as evidenced by the lower sleepiness score (p = 0.05, d = -0.84) in DG compared to CG. The mid-term use of such an environment showed to blind the higher baseline values of EEG-MWI recorded in DG compared to CG (p = 0.01, d = 1.05) and may prevent lower-back discomfort (i.e., a significant increase only in CG with p = 0.05 and d = 0.78), suggesting a less mentally and physically exhausting meeting in this environment. There were no acute and/or mid-term effects of the dynamic meeting environment on any of the HRV parameters. These findings are of relevance in the field of neuroergonomics, as they give preliminary support to the advantages of meeting in a dynamic office compared to a static office environment.
Collapse
Affiliation(s)
- Achraf Ammar
- Department of Training and Movement Science, Institute of Sport Science, Johannes Gutenberg-University Mainz, Mainz, Germany
- Interdisciplinary Laboratory in Neurosciences, Physiology and Psychology: Physical Activity, Health and Learning (LINP2), UFR STAPS (Faculty of Sport Sciences), UPL, Paris Nanterre University, Nanterre, France
- High Institute of Sport and Physical Education of Sfax, University of Sfax, Sfax, Tunisia
| | - Mohamed Ali Boujelbane
- Department of Training and Movement Science, Institute of Sport Science, Johannes Gutenberg-University Mainz, Mainz, Germany
- High Institute of Sport and Physical Education of Sfax, University of Sfax, Sfax, Tunisia
- Research Unit: Physical Activity, Sport, and Health, UR18JS01, National Observatory of Sport, Tunis, Tunisia
| | - Marvin Leonard Simak
- Department of Training and Movement Science, Institute of Sport Science, Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Irene Fraile-Fuente
- Department of Training and Movement Science, Institute of Sport Science, Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Khaled Trabelsi
- High Institute of Sport and Physical Education of Sfax, University of Sfax, Sfax, Tunisia
- Research Laboratory, Education, Motricity, Sport and Health (EM2S), LR15JS01, High Institute of Sport and Physical Education of Sfax, University of Sfax, Sfax, Tunisia
| | - Bassem Bouaziz
- MIRACL Laboratory, Higher Institute of Computer Science and Multimedia of Sfax, University of Sfax, Sfax, Tunisia
| | - Nikolas Rizzi
- Department of Training and Movement Science, Institute of Sport Science, Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Wolfgang I. Schöllhorn
- Department of Training and Movement Science, Institute of Sport Science, Johannes Gutenberg-University Mainz, Mainz, Germany
| |
Collapse
|
62
|
Topalidis PI, Baron S, Heib DPJ, Eigl ES, Hinterberger A, Schabus M. From Pulses to Sleep Stages: Towards Optimized Sleep Classification Using Heart-Rate Variability. SENSORS (BASEL, SWITZERLAND) 2023; 23:9077. [PMID: 38005466 PMCID: PMC10674316 DOI: 10.3390/s23229077] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 10/31/2023] [Accepted: 11/03/2023] [Indexed: 11/26/2023]
Abstract
More and more people quantify their sleep using wearables and are becoming obsessed in their pursuit of optimal sleep ("orthosomnia"). However, it is criticized that many of these wearables are giving inaccurate feedback and can even lead to negative daytime consequences. Acknowledging these facts, we here optimize our previously suggested sleep classification procedure in a new sample of 136 self-reported poor sleepers to minimize erroneous classification during ambulatory sleep sensing. Firstly, we introduce an advanced interbeat-interval (IBI) quality control using a random forest method to account for wearable recordings in naturalistic and more noisy settings. We further aim to improve sleep classification by opting for a loss function model instead of the overall epoch-by-epoch accuracy to avoid model biases towards the majority class (i.e., "light sleep"). Using these implementations, we compare the classification performance between the optimized (loss function model) and the accuracy model. We use signals derived from PSG, one-channel ECG, and two consumer wearables: the ECG breast belt Polar® H10 (H10) and the Polar® Verity Sense (VS), an optical Photoplethysmography (PPG) heart-rate sensor. The results reveal a high overall accuracy for the loss function in ECG (86.3 %, κ = 0.79), as well as the H10 (84.4%, κ = 0.76), and VS (84.2%, κ = 0.75) sensors, with improvements in deep sleep and wake. In addition, the new optimized model displays moderate to high correlations and agreement with PSG on primary sleep parameters, while measures of reliability, expressed in intra-class correlations, suggest excellent reliability for most sleep parameters. Finally, it is demonstrated that the new model is still classifying sleep accurately in 4-classes in users taking heart-affecting and/or psychoactive medication, which can be considered a prerequisite in older individuals with or without common disorders. Further improving and validating automatic sleep stage classification algorithms based on signals from affordable wearables may resolve existing scepticism and open the door for such approaches in clinical practice.
Collapse
Affiliation(s)
- Pavlos I. Topalidis
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology, Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria; (P.I.T.); (D.P.J.H.); (E.-S.E.)
| | - Sebastian Baron
- Department of Mathematics, Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
- Department of Artificial Intelligence and Human Interfaces (AIHI), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
| | - Dominik P. J. Heib
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology, Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria; (P.I.T.); (D.P.J.H.); (E.-S.E.)
- Institut Proschlaf, 5020 Salzburg, Austria
| | - Esther-Sevil Eigl
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology, Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria; (P.I.T.); (D.P.J.H.); (E.-S.E.)
| | - Alexandra Hinterberger
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology, Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria; (P.I.T.); (D.P.J.H.); (E.-S.E.)
| | - Manuel Schabus
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology, Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria; (P.I.T.); (D.P.J.H.); (E.-S.E.)
| |
Collapse
|
63
|
Ammann L, Chmura P. Internal and external load during on-field training drills with an aim of improving the physical performance of players in professional soccer: a retrospective observational study. Front Physiol 2023; 14:1212573. [PMID: 38028802 PMCID: PMC10661947 DOI: 10.3389/fphys.2023.1212573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 10/25/2023] [Indexed: 12/01/2023] Open
Abstract
Extensive research has led to evidence-based methodological recommendations for appropriate prescription and implementation of different training drills to improve the physical performance of professional soccer players, while also pointing out limitations of drills. Less is known about the current methods used in an ecological context and the extent to which evidence-based considerations are applied. Knowledge of current practices might also enable to identify pitfalls in successful implementation and/or deficiencies in the communication of scientific knowledge. Thus, the aim of this study was to quantify and compare the load that players experience in an ecological context during drills that are frequently used, and in which there is an intention to improve the players' physical capacities. Therefore, a retrospective observational cohort study was conducted over a 14-month period, analyzing 9 load measures during training drills of 39 players of a team competing in the highest Swiss league. The load experienced by players was statistically significant different between the assessed drill categories for each load measure (all p < .001). This indicates different drills provide different stimuli. HIIT drills proved to be a more powerful tool of getting players to cover distances at high-speed and to spend time at an intensity ≥90% HRmax compared to sided games. The sprint distance of players was very low in all sided games and in most cases also in HIIT drills, in the latter the players also hardly performed any deceleration. In small goal-oriented sided games, players covered a greater distance per minute when outside floaters were present. Particularly regarding an improvement of the players' aerobic capacity, the present data emphasize the relevance for coaches to ensure an appropriate exposure. In general, the importance of individual load management in professional soccer is highlighted.
Collapse
Affiliation(s)
| | - Paweł Chmura
- Department of Team Games, Wroclaw University of Health and Sport Sciences, Wrocław, Poland
| |
Collapse
|
64
|
El Ali A, Ney R, van Berlo ZMC, Cesar P. Is that My Heartbeat? Measuring and Understanding Modality-Dependent Cardiac Interoception in Virtual Reality. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS 2023; 29:4805-4815. [PMID: 37782606 DOI: 10.1109/tvcg.2023.3320228] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Measuring interoception ('perceiving internal bodily states') has diagnostic and wellbeing implications. Since heartbeats are distinct and frequent, various methods aim at measuring cardiac interoceptive accuracy (CIAcc). However, the role of exteroceptive modalities for representing heart rate (HR) across screen-based and Virtual Reality (VR) environments remains unclear. Using a PolarH10 HR monitor, we develop a modality-dependent cardiac recognition task that modifies displayed HR. In a mixed-factorial design (N=50), we investigate how task environment (Screen, VR), modality (Audio, Visual, Audio-Visual), and real-time HR modifications (±15%, ±30%, None) influence CIAcc, interoceptive awareness, mind-body measures, VR presence, and post-experience responses. Findings showed that participants confused their HR with underestimates up to 30%; environment did not affect CIAcc but influenced mind-related measures; modality did not influence CIAcc, however including audio increased interoceptive awareness; and VR presence inversely correlated with CIAcc. We contribute a lightweight and extensible cardiac interoception measurement method, and implications for biofeedback displays.
Collapse
|
65
|
Awada M, Becerik-Gerber B, Lucas G, Roll SC. Predicting Office Workers' Productivity: A Machine Learning Approach Integrating Physiological, Behavioral, and Psychological Indicators. SENSORS (BASEL, SWITZERLAND) 2023; 23:8694. [PMID: 37960394 PMCID: PMC10647707 DOI: 10.3390/s23218694] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 10/22/2023] [Accepted: 10/23/2023] [Indexed: 11/15/2023]
Abstract
This research pioneers the application of a machine learning framework to predict the perceived productivity of office workers using physiological, behavioral, and psychological features. Two approaches were compared: the baseline model, predicting productivity based on physiological and behavioral characteristics, and the extended model, incorporating predictions of psychological states such as stress, eustress, distress, and mood. Various machine learning models were utilized and compared to assess their predictive accuracy for psychological states and productivity, with XGBoost emerging as the top performer. The extended model outperformed the baseline model, achieving an R2 of 0.60 and a lower MAE of 10.52, compared to the baseline model's R2 of 0.48 and MAE of 16.62. The extended model's feature importance analysis revealed valuable insights into the key predictors of productivity, shedding light on the role of psychological states in the prediction process. Notably, mood and eustress emerged as significant predictors of productivity. Physiological and behavioral features, including skin temperature, electrodermal activity, facial movements, and wrist acceleration, were also identified. Lastly, a comparative analysis revealed that wearable devices (Empatica E4 and H10 Polar) outperformed workstation addons (Kinect camera and computer-usage monitoring application) in predicting productivity, emphasizing the potential utility of wearable devices as an independent tool for assessment of productivity. Implementing the model within smart workstations allows for adaptable environments that boost productivity and overall well-being among office workers.
Collapse
Affiliation(s)
- Mohamad Awada
- Department of Civil and Environmental Engineering, University of Southern California, Los Angeles, CA 90089, USA;
| | - Burcin Becerik-Gerber
- Department of Civil and Environmental Engineering, University of Southern California, Los Angeles, CA 90089, USA;
| | - Gale Lucas
- USC Institute for Creative Technologies, University of Southern California, Los Angeles, CA 90089, USA;
| | - Shawn C. Roll
- Chan Division of Occupational Science and Occupational Therapy, University of Southern California, Los Angeles, CA 90089, USA;
| |
Collapse
|
66
|
Michel MF, Girard O, Guillard V, Brechbuhl C. Well-being as a performance pillar: a holistic approach for monitoring tennis players. Front Sports Act Living 2023; 5:1259821. [PMID: 37789864 PMCID: PMC10544573 DOI: 10.3389/fspor.2023.1259821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Accepted: 09/06/2023] [Indexed: 10/05/2023] Open
Abstract
This perspective article aims to discuss the usefulness of tools that can assist tennis professionals effectively manage the well-being of their players. This includes identifying and monitoring meaningful metrics (i.e., training load, training intensity, heart rate variability), as well as careful planning of training and competition schedules with appropriate recovery periods. The use of innovative training methods (i.e., repeated-sprint training in hypoxia and heat training), and proper dietary practices, along with biometric assessment for young players, represents should be considered. Adopting a holistic approach to decision-making about training and competition, balancing both health and performance considerations, is crucial for tennis players and their support teams. More research is needed to refine best practices for enhancing tennis performance while prioritizing the well-being of players.
Collapse
Affiliation(s)
- Marie-Florine Michel
- Faculty of Sports Science, Aix-Marseille University, Marseille, France
- French Tennis Federation, Stade Roland-Garros, Paris, France
| | - Olivier Girard
- School of Human Sciences (Exercise and Sport Science), The University of Western Australia, Crawley, WA, Australia
| | | | - Cyril Brechbuhl
- French Tennis Federation, Stade Roland-Garros, Paris, France
| |
Collapse
|
67
|
Demareva V, Zayceva I, Viakhireva V, Zhukova M, Selezneva E, Tikhomirova E. Home-Based Dynamics of Sleepiness-Related Conditions Starting at Biological Evening and Later (Beyond Working). INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:6641. [PMID: 37681781 PMCID: PMC10487394 DOI: 10.3390/ijerph20176641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Revised: 08/17/2023] [Accepted: 08/22/2023] [Indexed: 09/09/2023]
Abstract
Shift work requires round-the-clock readiness to perform professional duties, and the workers' performance highly depends on their sleepiness level, which can be underestimated during a shift. Various factors, including the time of day, can influence sleepiness in shift workers. The objective of this study was to explore the dynamics of sleepiness-related conditions assessed through heart rate variability analysis, starting from the biological evening and continuing in vivo (at home), without the need for artificial alertness support. The participants solely performed regular evening household duties. A total of 32 recordings were collected from the Subjective Sleepiness Dynamics Dataset for analysis. At 8:00 p.m. and every 30 min thereafter, the participants completed cyclic sleepiness scales (the KSS and the SSS) until the time they went to bed, while their heart rate was recorded. The results of the study indicated that during the biological evening, high sleepiness is associated with a 'stressed' condition characterized by higher sympathetic activation. Later on, it is associated with a 'drowsy' condition characterized by higher parasympathetic activation and a decline in heart rate variability. Our findings provide evidence that the type of condition experienced during high sleepiness depends on the biological time. This should be taken into account when managing work regimes in shift work and developing alertness detectors.
Collapse
Affiliation(s)
- Valeriia Demareva
- Faculty of Social Sciences, Lobachevsky State University of Nizhny Novgorod, 603022 Nizhny Novgorod, Russia
| | | | | | | | | | | |
Collapse
|
68
|
Pająk A, Przybyło J, Augustyniak P. Touchless Heart Rate Monitoring from an Unmanned Aerial Vehicle Using Videoplethysmography. SENSORS (BASEL, SWITZERLAND) 2023; 23:7297. [PMID: 37631834 PMCID: PMC10459503 DOI: 10.3390/s23167297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 08/12/2023] [Accepted: 08/14/2023] [Indexed: 08/27/2023]
Abstract
Motivation: The advancement of preventive medicine and, subsequently, telemedicine drives the need for noninvasive and remote measurements in patients' natural environments. Heart rate (HR) measurements are particularly promising and extensively researched due to their quick assessment and comprehensive representation of patients' conditions. However, in scenarios such as endurance training or emergencies, where HR measurement was not anticipated and direct access to victims is limited, no method enables obtaining HR results that are suitable even for triage. Methods: This paper presents the possibility of remotely measuring of human HR from a series of in-flight videos using videoplethysmography (VPG) along with skin detection, human pose estimation and image stabilization methods. An unmanned aerial vehicle (UAV) equipped with a camera captured ten segments of video footage featuring volunteers engaged in free walking and running activities in natural sunlight. The human pose was determined using the OpenPose algorithm, and subsequently, skin areas on the face and forearms were identified and tracked in consecutive frames. Ultimately, HR was estimated using several VPG methods: the green channel (G), green-red difference (GR), excess green (ExG), independent component analysis (ICA), and a plane orthogonal to the skin (POS). Results: When compared to simultaneous readings from a reference ECG-based wearable recorder, the root-mean-squared error ranged from 17.7 (G) to 27.7 (POS), with errors of less than 3.5 bpm achieved for the G and GR methods. Conclusions: These results demonstrate the acceptable accuracy of touchless human pulse measurement with the accompanying UAV-mounted camera. The method bridges the gap between HR-transmitting wearables and emergency HR recorders, and it has the potential to be advantageous in training or rescue scenarios in mountain, water, disaster, or battlefield settings.
Collapse
Affiliation(s)
| | | | - Piotr Augustyniak
- Department of Biocybernetics and Biomedical Engineering, AGH University of Krakow, 30 Mickiewicz Ave., 30-059 Krakow, Poland; (A.P.); (J.P.)
| |
Collapse
|
69
|
Arney D, Zhang Y, Kennedy-Metz LR, Dias RD, Goldman JM, Zenati MA. An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:3890. [PMID: 37112231 PMCID: PMC10145698 DOI: 10.3390/s23083890] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 03/09/2023] [Accepted: 04/04/2023] [Indexed: 06/19/2023]
Abstract
Clinical alarm and decision support systems that lack clinical context may create non-actionable nuisance alarms that are not clinically relevant and can cause distractions during the most difficult moments of a surgery. We present a novel, interoperable, real-time system for adding contextual awareness to clinical systems by monitoring the heart-rate variability (HRV) of clinical team members. We designed an architecture for real-time capture, analysis, and presentation of HRV data from multiple clinicians and implemented this architecture as an application and device interfaces on the open-source OpenICE interoperability platform. In this work, we extend OpenICE with new capabilities to support the needs of the context-aware OR including a modularized data pipeline for simultaneously processing real-time electrocardiographic (ECG) waveforms from multiple clinicians to create estimates of their individual cognitive load. The system is built with standardized interfaces that allow for free interchange of software and hardware components including sensor devices, ECG filtering and beat detection algorithms, HRV metric calculations, and individual and team alerts based on changes in metrics. By integrating contextual cues and team member state into a unified process model, we believe future clinical applications will be able to emulate some of these behaviors to provide context-aware information to improve the safety and quality of surgical interventions.
Collapse
Affiliation(s)
- David Arney
- Medical Device Plug-and-Play Interoperability and Cybersecurity Program, Massachusetts General Hospital, Boston, MA 02115, USA
- Department of Anaesthesia, Harvard Medical School, Boston, MA 02115, USA
| | - Yi Zhang
- Medical Device Plug-and-Play Interoperability and Cybersecurity Program, Massachusetts General Hospital, Boston, MA 02115, USA
| | | | - Roger D. Dias
- STRATUS Center for Medical Simulation, Department of Emergency Medicine, Brigham and Women’s Hospital, Boston, MA 02115, USA
| | - Julian M. Goldman
- Medical Device Plug-and-Play Interoperability and Cybersecurity Program, Massachusetts General Hospital, Boston, MA 02115, USA
- Department of Anaesthesia, Harvard Medical School, Boston, MA 02115, USA
| | - Marco A. Zenati
- Division of Cardiac Surgery, Veterans Affairs Boston Healthcare System, Department of Surgery, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
70
|
Lin L, Ji X, Zhang L, Weng H, Wang X. Peak Running, Mechanical, and Physiological Demands of Professional Men's Field Hockey Matches. J Hum Kinet 2023; 87:133-141. [PMID: 37229408 PMCID: PMC10203845 DOI: 10.5114/jhk/161551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 11/10/2022] [Indexed: 05/27/2023] Open
Abstract
The aim of this study was to investigate the peak running, mechanical, and physiological demands of players of different positions in professional men's field hockey matches. Eighteen professional male field hockey players participated in the study, and data were collected in eleven official matches. Players wore GPS units (Vector S7, Catapult Sports) and heart rate (HR) monitors (Polar H1, Polar Electros) to collect physical and physiological data. Physical and physiological output of forwards, midfielders, and defenders in full matches and during 1-min peak periods was analysed. For all metrics and positions, the values identified for the 1-min peak periods were greater than the average values of match play (p < 0.05). In terms of 1-min peak period Player Load, all three positions were significantly different from each other. Forwards achieved the highest Player Load per minute, while defenders the lowest. The distance per minute, high-speed distance per minute, and the relative average heart rate of defenders were significantly lower than of midfielders and forwards (p < 0.05). The current study revealed the peak running, mechanical, and physiological demands of professional men's field hockey matches. It is recommended when prescribing training programmes, to consider not only match average demands, but also peak demands. Forwards and midfielders displayed similar peak demands, while defenders had the lowest demands in all metrics except the number of accelerations and decelerations per minute. Player Load per minute can be used to identify the differences in peak mechanical demands between forwards and midfielders.
Collapse
Affiliation(s)
- Liya Lin
- Sports Training Research Center, Guangdong Institute of Sport Science, Guangzhou, China
| | - Xinyi Ji
- APAC Team, Catapult Sports, Melbourne, Australia
| | - Li Zhang
- Sports Training Research Center, Guangdong Institute of Sport Science, Guangzhou, China
| | - Haiqin Weng
- Coaching Team, Guangdong Men’s Field Hockey Team, Guangzhou, China
| | - Xinyi Wang
- APAC Team, Catapult Sports, Melbourne, Australia
| |
Collapse
|
71
|
McLean MK, Weaver RG, Lane A, Smith MT, Parker H, Stone B, McAninch J, Matolak DW, Burkart S, Chandrashekhar MVS, Armstrong B. A Sliding Scale Signal Quality Metric of Photoplethysmography Applicable to Measuring Heart Rate across Clinical Contexts with Chest Mounting as a Case Study. SENSORS (BASEL, SWITZERLAND) 2023; 23:3429. [PMID: 37050488 PMCID: PMC10098585 DOI: 10.3390/s23073429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/06/2023] [Accepted: 03/17/2023] [Indexed: 06/19/2023]
Abstract
UNLABELLED Photoplethysmography (PPG) signal quality as a proxy for accuracy in heart rate (HR) measurement is useful in various public health contexts, ranging from short-term clinical diagnostics to free-living health behavior surveillance studies that inform public health policy. Each context has a different tolerance for acceptable signal quality, and it is reductive to expect a single threshold to meet the needs across all contexts. In this study, we propose two different metrics as sliding scales of PPG signal quality and assess their association with accuracy of HR measures compared to a ground truth electrocardiogram (ECG) measurement. METHODS We used two publicly available PPG datasets (BUT PPG and Troika) to test if our signal quality metrics could identify poor signal quality compared to gold standard visual inspection. To aid interpretation of the sliding scale metrics, we used ROC curves and Kappa values to calculate guideline cut points and evaluate agreement, respectively. We then used the Troika dataset and an original dataset of PPG data collected from the chest to examine the association between continuous metrics of signal quality and HR accuracy. PPG-based HR estimates were compared with reference HR estimates using the mean absolute error (MAE) and the root-mean-square error (RMSE). Point biserial correlations were used to examine the association between binary signal quality and HR error metrics (MAE and RMSE). RESULTS ROC analysis from the BUT PPG data revealed that the AUC was 0.758 (95% CI 0.624 to 0.892) for signal quality metrics of STD-width and 0.741 (95% CI 0.589 to 0.883) for self-consistency. There was a significant correlation between criterion poor signal quality and signal quality metrics in both Troika and originally collected data. Signal quality was highly correlated with HR accuracy (MAE and RMSE, respectively) between PPG and ground truth ECG. CONCLUSION This proof-of-concept work demonstrates an effective approach for assessing signal quality and demonstrates the effect of poor signal quality on HR measurement. Our continuous signal quality metrics allow estimations of uncertainties in other emergent metrics, such as energy expenditure that relies on multiple independent biometrics. This open-source approach increases the availability and applicability of our work in public health settings.
Collapse
Affiliation(s)
- Marnie K. McLean
- Department of Exercise Science, University of South Carolina, Columbia, SC 29208, USA
| | - R. Glenn Weaver
- Department of Exercise Science, University of South Carolina, Columbia, SC 29208, USA
| | - Abbi Lane
- Department of Exercise Science, University of South Carolina, Columbia, SC 29208, USA
| | - Michal T. Smith
- Department of Exercise Science, University of South Carolina, Columbia, SC 29208, USA
| | - Hannah Parker
- Department of Exercise Science, University of South Carolina, Columbia, SC 29208, USA
| | - Ben Stone
- College of Engineering and Computing, University of South Carolina, Columbia, SC 29208, USA
| | - Jonas McAninch
- College of Engineering and Computing, University of South Carolina, Columbia, SC 29208, USA
| | - David W. Matolak
- College of Engineering and Computing, University of South Carolina, Columbia, SC 29208, USA
| | - Sarah Burkart
- Department of Exercise Science, University of South Carolina, Columbia, SC 29208, USA
| | | | - Bridget Armstrong
- Department of Exercise Science, University of South Carolina, Columbia, SC 29208, USA
| |
Collapse
|
72
|
Romagnoli S, Ripanti F, Morettini M, Burattini L, Sbrollini A. Wearable and Portable Devices for Acquisition of Cardiac Signals while Practicing Sport: A Scoping Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:3350. [PMID: 36992060 PMCID: PMC10055735 DOI: 10.3390/s23063350] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 03/16/2023] [Accepted: 03/20/2023] [Indexed: 05/31/2023]
Abstract
Wearable and portable devices capable of acquiring cardiac signals are at the frontier of the sport industry. They are becoming increasingly popular for monitoring physiological parameters while practicing sport, given the advances in miniaturized technologies, powerful data, and signal processing applications. Data and signals acquired by these devices are increasingly used to monitor athletes' performances and thus to define risk indices for sport-related cardiac diseases, such as sudden cardiac death. This scoping review investigated commercial wearable and portable devices employed for cardiac signal monitoring during sport activity. A systematic search of the literature was conducted on PubMed, Scopus, and Web of Science. After study selection, a total of 35 studies were included in the review. The studies were categorized based on the application of wearable or portable devices in (1) validation studies, (2) clinical studies, and (3) development studies. The analysis revealed that standardized protocols for validating these technologies are necessary. Indeed, results obtained from the validation studies turned out to be heterogeneous and scarcely comparable, since the metrological characteristics reported were different. Moreover, the validation of several devices was carried out during different sport activities. Finally, results from clinical studies highlighted that wearable devices are crucial to improve athletes' performance and to prevent adverse cardiovascular events.
Collapse
Affiliation(s)
| | | | | | - Laura Burattini
- Department of Information Engineering, Università Politecnica delle Marche, 60131 Ancona, Italy; (S.R.); (F.R.); (M.M.); (A.S.)
| | | |
Collapse
|
73
|
Topalidis P, Heib DPJ, Baron S, Eigl ES, Hinterberger A, Schabus M. The Virtual Sleep Lab-A Novel Method for Accurate Four-Class Sleep Staging Using Heart-Rate Variability from Low-Cost Wearables. SENSORS (BASEL, SWITZERLAND) 2023; 23:2390. [PMID: 36904595 PMCID: PMC10006886 DOI: 10.3390/s23052390] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 02/07/2023] [Accepted: 02/11/2023] [Indexed: 06/18/2023]
Abstract
Sleep staging based on polysomnography (PSG) performed by human experts is the de facto "gold standard" for the objective measurement of sleep. PSG and manual sleep staging is, however, personnel-intensive and time-consuming and it is thus impractical to monitor a person's sleep architecture over extended periods. Here, we present a novel, low-cost, automatized, deep learning alternative to PSG sleep staging that provides a reliable epoch-by-epoch four-class sleep staging approach (Wake, Light [N1 + N2], Deep, REM) based solely on inter-beat-interval (IBI) data. Having trained a multi-resolution convolutional neural network (MCNN) on the IBIs of 8898 full-night manually sleep-staged recordings, we tested the MCNN on sleep classification using the IBIs of two low-cost (<EUR 100) consumer wearables: an optical heart rate sensor (VS) and a breast belt (H10), both produced by POLAR®. The overall classification accuracy reached levels comparable to expert inter-rater reliability for both devices (VS: 81%, κ = 0.69; H10: 80.3%, κ = 0.69). In addition, we used the H10 and recorded daily ECG data from 49 participants with sleep complaints over the course of a digital CBT-I-based sleep training program implemented in the App NUKKUAA™. As proof of principle, we classified the IBIs extracted from H10 using the MCNN over the course of the training program and captured sleep-related changes. At the end of the program, participants reported significant improvements in subjective sleep quality and sleep onset latency. Similarly, objective sleep onset latency showed a trend toward improvement. Weekly sleep onset latency, wake time during sleep, and total sleep time also correlated significantly with the subjective reports. The combination of state-of-the-art machine learning with suitable wearables allows continuous and accurate monitoring of sleep in naturalistic settings with profound implications for answering basic and clinical research questions.
Collapse
Affiliation(s)
- Pavlos Topalidis
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology and Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
| | - Dominik P. J. Heib
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology and Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
- Institut Proschlaf, 5020 Salzburg, Austria
| | - Sebastian Baron
- Department of Mathematics, Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
- Department of Artificial Intelligence and Human Interfaces (AIHI), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
| | - Esther-Sevil Eigl
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology and Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
| | - Alexandra Hinterberger
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology and Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
| | - Manuel Schabus
- Laboratory for Sleep, Cognition and Consciousness Research, Department of Psychology and Centre for Cognitive Neuroscience Salzburg (CCNS), Paris-Lodron University of Salzburg, 5020 Salzburg, Austria
| |
Collapse
|
74
|
Martín-Escudero P, Cabanas AM, Dotor-Castilla ML, Galindo-Canales M, Miguel-Tobal F, Fernández-Pérez C, Fuentes-Ferrer M, Giannetti R. Are Activity Wrist-Worn Devices Accurate for Determining Heart Rate during Intense Exercise? Bioengineering (Basel) 2023; 10:254. [PMID: 36829748 PMCID: PMC9952291 DOI: 10.3390/bioengineering10020254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/28/2023] [Accepted: 01/30/2023] [Indexed: 02/17/2023] Open
Abstract
The market for wrist-worn devices is growing at previously unheard-of speeds. A consequence of their fast commercialization is a lack of adequate studies testing their accuracy on varied populations and pursuits. To provide an understanding of wearable sensors for sports medicine, the present study examined heart rate (HR) measurements of four popular wrist-worn devices, the (Fitbit Charge (FB), Apple Watch (AW), Tomtom runner Cardio (TT), and Samsung G2 (G2)), and compared them with gold standard measurements derived by continuous electrocardiogram examination (ECG). Eight athletes participated in a comparative study undergoing maximal stress testing on a cycle ergometer or a treadmill. We analyzed 1,286 simultaneous HR data pairs between the tested devices and the ECG. The four devices were reasonably accurate at the lowest activity level. However, at higher levels of exercise intensity the FB and G2 tended to underestimate HR values during intense physical effort, while the TT and AW devices were fairly reliable. Our results suggest that HR estimations should be considered cautiously at specific intensities. Indeed, an effective intervention is required to register accurate HR readings at high-intensity levels (above 150 bpm). It is important to consider that even though none of these devices are certified or sold as medical or safety devices, researchers must nonetheless evaluate wrist-worn wearable technology in order to fully understand how HR affects psychological and physical health, especially under conditions of more intense exercise.
Collapse
Affiliation(s)
- Pilar Martín-Escudero
- Professional Medical School of Physical Education and Sport, Faculty of Medicine, Universidad Complutense de Madrid, 28040 Madrid, Spain
| | - Ana María Cabanas
- Departamento de Física, FACI, Universidad de Tarapacá, Arica 1010069, Chile
| | | | - Mercedes Galindo-Canales
- Professional Medical School of Physical Education and Sport, Faculty of Medicine, Universidad Complutense de Madrid, 28040 Madrid, Spain
| | - Francisco Miguel-Tobal
- Professional Medical School of Physical Education and Sport, Faculty of Medicine, Universidad Complutense de Madrid, 28040 Madrid, Spain
| | - Cristina Fernández-Pérez
- Servicio de Medicina Preventiva Complejo Hospitalario de Santiago de Compostela, Instituto de Investigación Sanitaria de Santiago, 15706 Santiago de Compostela, Spain
| | - Manuel Fuentes-Ferrer
- Unidad de Investigación, Hospital Universitario Nuestra Señora de Candelaria, 38010 Santa Cruz de Tenerife, Spain
| | - Romano Giannetti
- IIT, Institute of Technology Research, Universidad Pontificia Comillas, 28015 Madrid, Spain
| |
Collapse
|
75
|
Callihan M, Cole H, Stokley H, Gunter J, Clamp K, Martin A, Doherty H. Comparison of Slate Safety Wearable Device to Ingestible Pill and Wearable Heart Rate Monitor. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23020877. [PMID: 36679676 PMCID: PMC9865127 DOI: 10.3390/s23020877] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 01/04/2023] [Accepted: 01/11/2023] [Indexed: 06/12/2023]
Abstract
BACKGROUND With the increase in concern for deaths and illness related to the increase in temperature globally, there is a growing need for real-time monitoring of workers for heat stress indicators. The purpose of this study was to determine the usability of the Slate Safety (SS) wearable physiological monitoring system. METHODS Twenty nurses performed a common task in a moderate or hot environment while wearing the SS device, the Polar 10 monitor, and having taken the e-Celsius ingestible pill. Data from each device was compared for correlation and accuracy. RESULTS High correlation was determined between the SS wearable device and the Polar 10 system (0.926) and the ingestible pill (0.595). The SS was comfortable to wear and easily monitored multiple participants from a distance. CONCLUSIONS The Slate Safety wearable device demonstrated accuracy in measuring core temperature and heart rate while not restricting the motion of the worker, and provided a remote monitoring platform for physiological parameters.
Collapse
|