101
|
Zalis ME, Perumpillichira J, Del Frate C, Hahn PF. CT colonography: digital subtraction bowel cleansing with mucosal reconstruction initial observations. Radiology 2003; 226:911-7. [PMID: 12601218 DOI: 10.1148/radiol.2263012059] [Citation(s) in RCA: 94] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The authors evaluated a computed tomography (CT) colonographic technique with a combination of preexamination orally ingested positive contrast material and postacquisition image processing to subtract out the ingested opacified bowel contents. With this technique, rigorous physical purging of the bowel was not necessary before structural examination of the colon. With images obtained in 20 patients, two readers were able to correctly identify the majority of polyps confirmed at colonoscopy. Their performance for detection of lesions larger than 1 cm was similar to that with conventional CT colonography.
Collapse
Affiliation(s)
- Michael E Zalis
- Department of Radiology, Division of Abdominal Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114, USA.
| | | | | | | |
Collapse
|
102
|
Yee J, Kumar NN, Hung RK, Akerkar GA, Kumar PRG, Wall SD. Comparison of supine and prone scanning separately and in combination at CT colonography. Radiology 2003; 226:653-61. [PMID: 12601201 DOI: 10.1148/radiol.2263010701] [Citation(s) in RCA: 132] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE To compare colonic distention, adequacy of colonic preparation, and colorectal polyp detection as assessed with supine and prone scanning separately and in combination at computed tomographic (CT) colonography. MATERIALS AND METHODS CT colonography and colonoscopy were performed in 182 patients. Distention and preparation of eight colonic segments were rated separately on a scale of 1-4 (1, segment completely distended or no residual material; 4, segment collapsed or large amounts of residual material). The distention, preparation, and polyp detection data were compared with regard to each position alone and then in combination. CT findings were correlated with colonoscopic findings. RESULTS The percentage of colonic segments with grade 1 distention and preparation was 93.7% (1,364 of 1,456) and 66.6% (969 of 1,456), respectively, with combined scanning; 86.4% (1,258 of 1,456) and 52.1% (759 of 1,456), respectively, with supine scanning alone; and 85.6% (1,246 of 1,456) and 57.1% (831 of 1,456), respectively, with prone scanning alone. The sensitivity for detection of colorectal polyps 10 mm or larger, 5.0-9.9 mm, and smaller than 5 mm and polyps of all sizes was 92.7%, 79.8%, 60.3%, and 69.9%, respectively, with combined scanning. Sensitivity was 58.5%, 47.2%, 36.3%, and 42.1%, respectively, with supine scanning and 51.2%, 41.6%, 30.2%, and 36.3%, respectively, with prone scanning. The improved sensitivities for use of combined versus individual scanning positions were highly significant (P <.001) for polyps in all size categories. CONCLUSION Colonic distention and preparation at CT colonography were significantly improved by using supine and prone scanning in combination, and results correlated directly with improved sensitivity of polyp detection.
Collapse
Affiliation(s)
- Judy Yee
- Department of Radiology (114), Veterans Affairs Medical Center, 4150 Clement St, San Francisco, CA 94121, USA.
| | | | | | | | | | | |
Collapse
|
103
|
|
104
|
Abstract
CT colonography (Virtual Colonoscopy) was first introduced in 1994 as a novel imaging technique for the detection of colorectal polyps and cancer. It is currently proposed as a new screening tool for colorectal carcinoma that may be more acceptable to patients than current methods. There are a growing number of published studies evaluating all aspects of CT colonography, including technique, imaging displays, interpretation methods, patient acceptance, and lesion detection accuracy. While there are multiple studies that have found excellent CT colonography results for the detection of larger polyps in high risk or symptomatic patient cohorts, there are very few published studies evaluating the performance of CT colonography in asymptomatic screening patients. Although we do not have the results of large, randomized, controlled trials documenting the performance of CT colonography in screening-type patients, this technique is currently employed at some sites as a screening tool for colorectal carcinoma. Thus, CT colonography has become a part of the controversy surrounding total body CT screening. In this article, the current techniques for colonic preparation and distention will be discussed, as well as the optimum CT protocol, and the recommended use of image displays for time-efficient interpretation. The results of the larger and newer studies will be presented, as well as some of the current clinical uses of CT colonography. Issues specific to the use of CT colonography as a screening test will also be discussed.
Collapse
Affiliation(s)
- Judy Yee
- UCSF, Veterans Affairs Medical Center (114), San Francisco, CA 94121, USA.
| |
Collapse
|
105
|
Abstract
Virtual colonoscopy is a promising new technique that combines rapid spiral CT scanning of the abdomen with advanced computer programs capable of re-creating two- and three-dimensional views of the colon and rectum. Recent studies comparing this method with conventional colonoscopy show that virtual colonoscopy already is more accurate than barium enema X-ray studies for the detection of colorectal polyps, and that it approaches the accuracy of colonoscopy for diagnosing advanced lesions. Before virtual colonoscopy can be promoted for population-based screening for colorectal cancer, a number of issues discussed in this review need to be addressed. These include questions of accuracy, availability, acceptability, and cost-effectiveness.
Collapse
Affiliation(s)
- John H Bond
- Gastroentreology Section, VA Medical Center, Minneapolis, MN 55417, USA
| |
Collapse
|
106
|
Abstract
The development of colorectal cancer screening alternatives that are attractive to patients and effective for screening is critical for reducing this too-common and deadly disease. CTC is an exciting technique that is the only imaging alternative developed since the barium enema for colon screening. In the past few years, many obstacles to clinical implementation of CTC have been eliminated. For example, there is no longer any post-processing time, which was previously as long as 8 to 10 hours, and the interpretation time has been drastically reduced from 4 hours to 15 to 20 minutes. The majority of studies have demonstrated excellent results for detection of lesions > or = 1 cm, with few false positives. This examination will continue to improve with the development of automated (computer) detection programs and automated 3D rendering algorithms. In addition, cathartic bowel preparation, one of the biggest obstacles to patient compliance with colorectal cancer screening, may be eliminated if successful fecal tagging can be developed. The most important issue that remains is its performance in a screening population, and studies are currently underway to answer that important question.
Collapse
Affiliation(s)
- Amy K Hara
- Department of Radiology, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, AZ 85259, USA.
| |
Collapse
|
107
|
Acar B, Beaulieu CF, Göktürk SB, Tomasi C, Paik DS, Jeffrey RB, Yee J, Napel S. Edge displacement field-based classification for improved detection of polyps in CT colonography. IEEE TRANSACTIONS ON MEDICAL IMAGING 2002; 21:1461-1467. [PMID: 12588030 DOI: 10.1109/tmi.2002.806405] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and less invasive alternative to FOC. It would be desirable to have computer-aided detection (CAD) algorithms to examine the large amount of data CTC provides. Most current CAD algorithms have high false positive rates at the required sensitivity levels. We developed and evaluated a postprocessing algorithm to decrease the false positive rate of such a CAD method without sacrificing sensitivity. Our method attempts to model the way a radiologist recognizes a polyp while scrolling a cross-sectional plane through three-dimensional computed tomography data by classification of the changes in the location of the edges in the two-dimensional plane. We performed a tenfold cross-validation study to assess its performance using sensitivity/specificity analysis on data from 48 patients. The mean specificity over all experiments increased from 0.19 (0.35) to 0.47 (0.56) for a sensitivity of 1.00 (0.95).
Collapse
Affiliation(s)
- Burak Acar
- Department of Radiology, LUCAS MRS Center, 3D Laboratory, Stanford University, Stanford, CA 94305, USA.
| | | | | | | | | | | | | | | |
Collapse
|
108
|
Affiliation(s)
- Judy Yee
- Department of Radiology, UCSF Veterans Affairs Medical Center, 4150 Clement St, San Francisco, CA 94121, USA.
| |
Collapse
|
109
|
McFarland EG, Pilgram TK, Brink JA, McDermott RA, Santillan CV, Brady PW, Heiken JP, Balfe DM, Weinstock LB, Thyssen EP, Littenberg B. CT colonography: multiobserver diagnostic performance. Radiology 2002; 225:380-90. [PMID: 12409570 DOI: 10.1148/radiol.2252011625] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE To prospectively evaluate multiobserver diagnostic performance and reader agreement for colorectal polyp detection in a well-characterized cohort of patients with increased number of polyps, compared with an average-risk patient, with colonoscopy as the reference standard. MATERIALS AND METHODS A cohort of 70 patients suspected of having polyps was examined with spiral computed tomographic (CT) colonography, with colonoscopy performed the same day. After air insufflation per rectum, supine and prone images were obtained with single-detector row CT (5-mm collimation, 8-mm table increment, 2-mm reconstruction interval). Images were analyzed independently by four experienced abdominal radiologists using two-dimensional multiplanar reformation followed by selective use of three-dimensional endoscopic volume-rendered images. Data were analyzed both per polyp and per patient. RESULTS Analysis per polyp demonstrated a pooled sensitivity of 0.68 for lesions 10 mm or larger (n = 40), with 75% agreement among the four readers. Analysis per patient demonstrated improved detection and agreement, with a pooled sensitivity of 0.88 for patients with polyps or cancers 10 mm or larger (n = 28), with 94% agreement. When sensitivity and receiver operating characteristic analyses were analyzed per polyp size threshold, results among readers converged and peaked at polyp diameters of approximately 10 mm. CONCLUSION In this patient cohort, diagnostic performance and interobserver agreement with single-detector row CT colonography was sufficient for detection of patients with lesions 10 mm or larger, with more variable results for smaller polyps.
Collapse
Affiliation(s)
- Elizabeth G McFarland
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
110
|
Abstract
The potential role of virtual colonoscopy is not limited to colorectal cancer screening, although that is its greatest potential. Same-day VC should be offered for patients undergoing an incomplete colonoscopy. Conversely, faster, more accurate interpretation by the radiologist on the same day as a VC should lead to the consideration by the gastroenterologist of same-day colonoscopy for patients with a suspicious, significantly sized polyp.
Collapse
Affiliation(s)
- Abraham H Dachman
- Department of Radiology, MC 2026, University of Chicago, 5841 South Maryland Avenue, Chicago, IL 60637, USA.
| |
Collapse
|
111
|
Kim JK, Ahn JH, Park T, Ahn HJ, Kim CS, Cho KS. Virtual cystoscopy of the contrast material-filled bladder in patients with gross hematuria. AJR Am J Roentgenol 2002; 179:763-8. [PMID: 12185059 DOI: 10.2214/ajr.179.3.1790763] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the usefulness of virtual cystoscopy of the contrast material-filled bladder in evaluating patients with gross hematuria. SUBJECTS AND METHODS Seventy-three consecutive patients who had gross hematuria and whose upper urinary tracts had a normal appearance on single-detector helical CT scans were prospectively evaluated with virtual cystoscopy. Source CT data for virtual cystoscopy were obtained on a multidetector CT scanner with 1.25-mm slice thickness and transferred to a workstation for interactive navigation using volume rendering. Two radiologists independently interpreted the virtual cystoscopic images, and discrepancies were resolved by consensus. All patients also underwent conventional cystoscopy. We assessed the agreement between the findings on virtual and conventional cystoscopy. Using conventional cystoscopy as the gold standard, we evaluated the usefulness of virtual cystoscopy as an aid in identifying bladder lesions and detecting abnormal bladders. RESULTS Virtual cystoscopy depicted 60 lesions in the bladders of 43 patients. Fifty-six lesions (in 41 bladders) revealed on virtual cystoscopy were true-positive findings. Four lesions in two bladders with abnormal findings were false-positive. On virtual cystoscopy, the radiologists missed three lesions in two abnormal bladders that were identified on conventional cystoscopy. On virtual cystoscopy, 15 (88%) of 17 lesions smaller than 0.5 cm were identified. The agreement between the findings of virtual and conventional cystoscopy was excellent in the reviewers' identification of bladder lesions (kappa = 0.83) and detection of abnormal bladders (kappa = 0.89). The sensitivity and specificity of virtual cystoscopy were 95% and 87% for identifying bladder lesions and 95% and 93% for detecting abnormal bladders. CONCLUSION Virtual cystoscopy of the contrast material-filled bladder is useful for the evaluation of the bladder in patients with gross hematuria.
Collapse
Affiliation(s)
- Jeong Kon Kim
- Department of Radiology, Asan Medical Center, University of Ulsan, 388-1 Poongnap-dong, Songpa-gu, Seoul, 138-736, South Korea
| | | | | | | | | | | |
Collapse
|
112
|
Macari M, Bini EJ, Xue X, Milano A, Katz SS, Resnick D, Chandarana H, Krinsky G, Klingenbeck K, Marshall CH, Megibow AJ. Colorectal neoplasms: prospective comparison of thin-section low-dose multi-detector row CT colonography and conventional colonoscopy for detection. Radiology 2002; 224:383-92. [PMID: 12147833 DOI: 10.1148/radiol.2242011382] [Citation(s) in RCA: 199] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE To prospectively compare thin-section low-dose multi-detector row computed tomographic (CT) colonography with conventional colonoscopy for the detection of colorectal neoplasms. MATERIALS AND METHODS One hundred five patients underwent CT colonography immediately before colonoscopy. Supine and prone CT colonographic acquisitions to image the region during a 30-second breath hold were performed. CT colonographic images were prospectively interpreted for the presence, location, size, and morphologic features of polyps. The time of image interpretation was noted. Sensitivity, specificity, and positive and negative predictive values of CT colonography were calculated, with 95% CIs, by using colonoscopic findings as the reference standard. The weighted CT dose index was calculated on the basis of measurements in a standard body phantom. Effective dose was calculated by using commercially available software. RESULTS Median CT data interpretation time was 12 minutes. One hundred thirty-two polyps in 59 patients were identified at colonoscopy; no polyps were detected in 46 patients. Sensitivities for detection of polyps smaller than 5 mm, 6-9 mm, and larger than 10 mm in diameter were 12% (11 of 91 polyps), 70% (19 of 27 polyps), and 93% (13 of 14 polyps), respectively. Estimated overall specificity was 97.7% (515 of 527 imaging results). The total weighted CT dose index for combined supine and prone CT colonography was 11.4 mGy. The effective doses for combined CT colonography were 5.0 mSv and 7.8 mSv for men and women, respectively. CONCLUSION Low-dose multi-detector row CT colonography has excellent sensitivity and specificity for detection of colorectal neoplasms 10 mm and larger.
Collapse
Affiliation(s)
- Michael Macari
- Department of Radiology, New York University Medical Center, Tisch Hospital, 560 First Ave, Suite HW 207, New York, NY 10016, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
113
|
Lefere PA, Gryspeerdt SS, Dewyspelaere J, Baekelandt M, Van Holsbeeck BG. Dietary fecal tagging as a cleansing method before CT colonography: initial results polyp detection and patient acceptance. Radiology 2002; 224:393-403. [PMID: 12147834 DOI: 10.1148/radiol.2241011222] [Citation(s) in RCA: 196] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
PURPOSE To compare reduced colonic cleansing based on dietary fecal tagging (FT) with standard (non-FT) colonic cleansing with regard to patient acceptance, sensitivity, and specificity. MATERIALS AND METHODS In 50 patients (FT group), FT was performed by means of diet, magnesium citrate, and a barium suspension. In another 50 patients (non-FT group), preparation was based on polyethylene glycol administration. All patients underwent conventional colonoscopy after computed tomographic (CT) colonography. Sensitivity and specificity for polyp detection were calculated by using conventional colonography as the reference standard. At CT colonography, fecal residue was evaluated. Patients were interviewed to determine discomfort, side effects, sleep quality, final opinion on examination comfort, and whether they would be reluctant to undergo the same examination again. RESULTS FT left more fecal residue but improved differentiation from polyps (FT specificity, 88% [30 of 34 patients]; non-FT, 77% [23 of 30 patients]). Sensitivities were comparable: FT, 88% (14 of 16 patients); non-FT, 85% (17 of 20 patients). FT significantly reduced discomfort, side effects, and sleep disturbance, and resulted in an improved final opinion of how comfortable the examination was (P <.05). Although FT improved patient willingness to repeat the examination, this improvement was not statistically significant (P >.05). CONCLUSION FT offers the patient a well-tolerated preparation and improves specificity, with improved differentiation of polyps from residual stool.
Collapse
Affiliation(s)
- Philippe A Lefere
- Department of Radiology, Stedelijk Ziekenhuis, Bruggesteenweg 90, 8800 Roeselare, Belgium.
| | | | | | | | | |
Collapse
|
114
|
van Gelder RE, Venema HW, Serlie IWO, Nio CY, Determann RM, Tipker CA, Vos FM, Glas AS, Bartelsman JFW, Bossuyt PMM, Laméris JS, Stoker J. CT colonography at different radiation dose levels: feasibility of dose reduction. Radiology 2002; 224:25-33. [PMID: 12091658 DOI: 10.1148/radiol.2241011126] [Citation(s) in RCA: 162] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
PURPOSE To investigate the sensitivity and specificity of polyp detection and the image quality of computed tomographic (CT) colonography at different radiation dose levels and to study effective doses reported in literature on CT colonography. MATERIALS AND METHODS CT colonography and colonoscopy were performed with 100 mAs in 50 consecutive patients at high risk for colorectal cancer; 50- and 30-mAs CT colonographic examinations were simulated with controlled addition of noise to raw transmission measurements. One radiologist randomly evaluated all original and simulated images for the presence of polyps and scored image quality. Differences in image quality were assessed with the Wilcoxon rank test. Scan protocols from the literature and recent (unpublished) updates were collected. RESULTS In nine of 10 patients with polyps 5 mm in diameter or larger (sensitivity, 90%) and in seven of 17 patients with polyps smaller than 5 mm, polyps were correctly identified with CT colonography at all dose levels. Specificity for patients without polyps 5 mm or larger was 53%-60% at all dose levels and for patients without any polyps was 26% (at 100 and 50 mAs) and 48% (at 30 mAs). Image quality decreased significantly as the dose level decreased. The median effective doses (supine and prone positions) calculated from protocols reported in the literature and updates were 7.8 and 8.8 mSv, respectively. CONCLUSION Although image quality decreases significantly at 30 mAs (3.6 mSv), polyp detection remains unimpaired. The median dose for CT colonography at institutions that perform CT colonographic research is currently 8.8 mSv.
Collapse
Affiliation(s)
- Rogier E van Gelder
- Department of Radiology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
115
|
Yoshida H, Näppi J, MacEneaney P, Rubin DT, Dachman AH. Computer-aided diagnosis scheme for detection of polyps at CT colonography. Radiographics 2002; 22:963-79. [PMID: 12110726 DOI: 10.1148/radiographics.22.4.g02jl16963] [Citation(s) in RCA: 126] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Colon cancer is one of the leading causes of cancer deaths in the United States. However, most colon cancers can be prevented if precursor colonic polyps are detected and removed. An advanced computer-aided diagnosis (CAD) scheme was developed for the automated detection of polyps at computed tomographic (CT) colonography. A region encompassing the colonic wall is extracted from an isotropic volume data set obtained by interpolating CT colonographic scans along the axial direction. Polyp candidates are detected with computation of three-dimensional (3D) geometric features that characterize polyps, followed by extraction of polyps with hysteresis thresholding and fuzzy clustering using these geometric features. The number of false-positive findings is reduced by extracting 3D texture features from polyp candidates and applying quadratic discriminant analysis to the candidates. This CAD scheme was applied in 71 patients who underwent CT colonography, 14 of whom had colonoscopically confirmed polyps (n = 21). At by-patient analysis, sensitivity was 100%, with an average false-positive rate of 2.0 per patient. At by-polyp analysis, the scheme detected 90% of the polyps at the same false-positive rate. This CAD scheme permits accurate detection of suspicious lesions and thus has the potential to reduce radiologists' interpretation time and improve their diagnostic accuracy in the detection of polyps at CT colonography.
Collapse
Affiliation(s)
- Hiroyuki Yoshida
- Department of Radiology, University of Chicago, 5841 S Maryland Ave, MC20206, IL 60637, USA.
| | | | | | | | | |
Collapse
|
116
|
Näppi J, Dachman AH, MacEneaney P, Yoshida H. Automated knowledge-guided segmentation of colonic walls for computerized detection of polyps in CT colonography. J Comput Assist Tomogr 2002; 26:493-504. [PMID: 12218808 DOI: 10.1097/00004728-200207000-00003] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE We have developed a novel automated technique for segmenting colonic walls for the application of computer-aided polyp detection in CT colonography. In particular, the technique was designed to minimize the presence of extracolonic components, such as small bowel, in the segmented colon. METHODS The segmentation technique combines an improved version of our previously reported anatomy-oriented colon segmentation technique with a colon-based analysis step that performs self-adjusting volume-growing within the colonic lumen. Extracolonic components are eliminated by intersecting of the resulting two segmentations, so that the colonic walls remain in the intersection. The technique was evaluated on 88 CT colonography datasets. The colon segmentations were evaluated subjectively by four radiologists, as well as objectively by performance of an automated polyp detection on the segmentation. For comparison, the tests were also performed for the anatomy-oriented colon segmentation technique. RESULTS On average, the technique covered 98% of the visible colonic walls. Approximately 50% of the extracolonic components remaining in the anatomy-oriented segmentation were removed, but 10-15% of the segmentation still contained extracolonic components. The dataset-based false-positive rate of the automated polyp detection was improved by 10% without compromising the 100% case-based sensitivity, and the case-based false-positive rate was improved by 15% over the previous false-positive rate. CONCLUSIONS The technique segments practically all of the colonic walls in the region of diagnostic quality with a large reduction in the amount of extracolonic components over our previously used technique. The new segmentation improves the specificity of our computer-aided polyp detection scheme significantly without any degradation in detection sensitivity.
Collapse
Affiliation(s)
- Janne Näppi
- Department of Radiology, The University of Chicago, Il 60637, USA.
| | | | | | | |
Collapse
|
117
|
Affiliation(s)
- Judy Yee
- Department of Radiology, Veterans Affairs Medical Center and University of California School of Medicine, San Francisco, California 94121, USA.
| |
Collapse
|
118
|
Power NP, Pryor MD, Martin A, Horrocks J, McLean AM, Reznek RH. Optimization of scanning parameters for CT colonography. Br J Radiol 2002; 75:401-8. [PMID: 12036832 DOI: 10.1259/bjr.75.893.750401] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
To determine the optimal collimation, pitch and reconstruction interval for CT colonography, 10 spherical polyps between 1 mm and 10 mm diameter and made of tissue equivalent material with a CT number of 40 Hounsfield units (HU) were placed in the colon of an anthropomorphic phantom. The phantom was scanned at slice thicknesses of 3 mm, 5 mm and 7 mm and pitches of 1.0, 1.3, 1.5, 1.7 and 2.0 on an IGE Hispeed advantage system. Images were reconstructed for each scanning parameter at the minimum intervals allowed along the z-axis. The optimum scanning protocol was assessed by measuring maximum contrast between the polyp and air, sensitivity for detection of each polyp along the z-axis, and relative radiation dose. In addition, images were reviewed separately by two radiologists who graded polyp conspicuity as: 0, not seen; 1, faintly seen; 2, well seen. It was found that varying the scanning parameters caused a marked alteration in the maximum contrast between each polyp and air. For example, for the 5 mm polyp, the range of contrasts from best to worst case was 910-490 HU. It was noted that with contrasts of less than 500 HU, polyps were only faintly seen. A slice thickness of 3 mm with a pitch of 2 offers optimal polyp conspicuity with a relatively low radiation dose, we conclude that scanning parameters can be optimized for threshold contrast, radiation dose and subjective conspicuity. We propose an optimal parameter of 3 mm slice thickness and pitch 2.
Collapse
Affiliation(s)
- N P Power
- Department of Radiology, St. Bartholomew's Hospital, West Smithfield, London EC1A 7EB, UK
| | | | | | | | | | | |
Collapse
|
119
|
Abstract
Computerized tomographic colonography (CT colonography) is a new, non-invasive technique that has been developed over the last few years; it looks at the large bowel in detail. In this chapter we look at how the examination is performed and we consider how the images are displayed. We describe the normal features of the colon, as seen using this technique, as well as the features of common pathological conditions. We will discuss screening for colorectal cancer and the performance of CT colonography; we compare the latter with other procedures currently employed in the screening and diagnosis of colorectal pathology. We consider the difficulties in interpreting these CT colonographic images and look at ways to overcome such difficulties. Finally we discuss future developments of this exciting, new technique.
Collapse
Affiliation(s)
- Clare S Smith
- Department of Radiology, Mater Misercordiae Hospital, Eccles Street, Dublin 7, Ireland
| | | |
Collapse
|
120
|
Näppi J, Yoshida H. Automated detection of polyps with CT colonography: evaluation of volumetric features for reduction of false-positive findings. Acad Radiol 2002; 9:386-97. [PMID: 11942653 DOI: 10.1016/s1076-6332(03)80184-8] [Citation(s) in RCA: 91] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
RATIONALE AND OBJECTIVES To achieve high performance in computer-assisted diagnosis (CAD) of polyps with computed tomographic (CT) colonography, the authors (a) developed new gradient concentration and directional gradient concentration (DGC) features for differentiating between the true-positive and false-positive (FP) findings generated by the authors' CAD scheme, and (b) used receiver operating characteristic (ROC) analysis to quantify the differentiation performance of these and other volumetric features. MATERIALS AND METHODS CT colonography was performed in 43 patients prone and supine with a helical CT scanner; there were 12 polyps in 11 patients. The polyp candidates generated by the authors' CAD scheme were characterized by nine statistics of six volumetric features, and the resulting 54 feature statistics were combined by a linear or quadratic discriminant classifier. The discrimination performance was measured with round-robin method by ROC analysis and the FP rate of the CAD scheme. RESULTS The mean value of shape index (SI) yielded the highest individual ROC performance (area under the curve = 0.92). Among combinations, the mean values of SI and DGC and the variance of CT value yielded a high ROC performance (area under the curve = 0.95). With quadratic classifier, the sensitivity and FP rate of the case-based (data set-based) analysis was 100% (95%) with 2.4 FP findings per patient (1.7 FP findings per data set), respectively. CONCLUSION Combination of the mean values of SI and DGC and the variance of CT value reduced the FP rate substantially without sacrificing sensitivity. These three features are potentially useful in improving the performance of the authors' CAD scheme for detecting polyps with CT colonography.
Collapse
Affiliation(s)
- Janne Näppi
- Department of Radiology, University of Chicago, IL 60637, USA
| | | |
Collapse
|
121
|
Mendelson RM, Forbes GM. Computed tomography colonography (virtual colonoscopy): review. AUSTRALASIAN RADIOLOGY 2002; 46:1-12. [PMID: 11966581 DOI: 10.1046/j.1440-1673.2001.00988.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Computed tomography examination of the colon performed after bowel cleansing and distension of the lumen with gas goes by several different names--CT colonography (CTC) and CT colography perhaps being the most common. Strictly, the term 'virtual colonoscopy' (VC), should be reserved for the process of examining 3-D, simulated endoluminal images with a capability to navigate through the bowel using appropriate software. Computed tomography colonography appears to be the name that has gained favour among radiologists, although it is suspected that 'virtual colonoscopy' will persist as a generic term due to its attractive 'high-tech' connotations for non-radiological medical and lay persons. Whatever the name, the technique has been made possible through the advent of fast helical CT scanners which allow acquisition of a volume of data, and of proprietary software which enables multiplanar reformatting and 3-D endoluminal reconstructions. It is evident that if CTC/VC can be shown to be acceptable to patients, safe, affordable and accurate, it has enormous potential as a diagnostic and screening tool for colorectal neoplasia.
Collapse
|
122
|
Laghi A, Iannaccone R, Carbone I, Catalano C, Di Giulio E, Schillaci A, Passariello R. Detection of colorectal lesions with virtual computed tomographic colonography. Am J Surg 2002; 183:124-31. [PMID: 11918874 DOI: 10.1016/s0002-9610(01)00857-1] [Citation(s) in RCA: 83] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND The aim of our study was to compare the performance of virtual computed tomographic colonography with that of conventional colonoscopy in a blinded, prospective study in 165 patients with suspected colorectal lesions. METHODS There were 165 patients, all referred for conventional colonoscopy, who underwent preliminary virtual computed tomographic colonography. Computed tomograhic images of all suspected lesions were analyzed and subsequently compared with conventional colonoscopy findings. RESULTS There were 30 colorectal cancers and 37 polyps identified at conventional colonoscopy. Virtual computed tomographic colonography correctly detected all cancers, as well as 11 of 12 polyps of 10 mm in diameter or larger (sensitivity, 92%); 14 of 17 polyps between 6 and 9 mm (sensitivity, 82%); and 4 of 8 polyps of 5 mm or smaller (sensitivity, 50%). The per-patient sensitivity and specificity were 92% and 97%, respectively. CONCLUSIONS Virtual computed tomographic colonography has a diagnostic sensitivity similar to that of conventional colonoscopy for the detection of colorectal lesions larger than 6 mm in diameter.
Collapse
Affiliation(s)
- Andrea Laghi
- Department of Radiology-II Chair, University of Rome, La Sapienza, Policlinico Umberto I, Rome, Italy.
| | | | | | | | | | | | | |
Collapse
|
123
|
Hung PW, Paik DS, Napel S, Yee J, Jeffrey RB, Steinauer-Gebauer A, Min J, Jathavedam A, Beaulieu CF. Quantification of distention in CT colonography: development and validation of three computer algorithms. Radiology 2002; 222:543-54. [PMID: 11818626 DOI: 10.1148/radiol.2222010600] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Three bowel distention-measuring algorithms for use at computed tomographic (CT) colonography were developed, validated in phantoms, and applied to a human CT colonographic data set. The three algorithms are the cross-sectional area method, the moving spheres method, and the segmental volume method. Each algorithm effectively quantified distention, but accuracy varied between methods. Clinical feasibility was demonstrated. Depending on the desired spatial resolution and accuracy, each algorithm can quantitatively depict colonic diameter in CT colonography.
Collapse
Affiliation(s)
- Peter W Hung
- Department of Radiology, Stanford University Medical Center, MC 5105, 300 Pasteur Dr, Stanford, CA 94305, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
124
|
Fletcher JG, Johnson CD, Krueger WR, Ahlquist DA, Nelson H, Ilstrup D, Harmsen WS, Corcoran KE. Contrast-enhanced CT colonography in recurrent colorectal carcinoma: feasibility of simultaneous evaluation for metastatic disease, local recurrence, and metachronous neoplasia in colorectal carcinoma. AJR Am J Roentgenol 2002; 178:283-90. [PMID: 11804881 DOI: 10.2214/ajr.178.2.1780283] [Citation(s) in RCA: 63] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE Contrast-enhanced CT colonography has the potential to detect local recurrence, metachronous disease, and distant metastases in patients with a history of invasive colorectal cancer. The purpose of our study was to determine whether colonic anastomoses prohibit adequate colonic distention on contrast-enhanced CT colonography and to estimate the performance of contrast-enhanced CT colonography in detecting recurrent colorectal carcinoma. MATERIALS AND METHODS Fifty patients with a history of resected invasive colorectal carcinoma underwent contrast-enhanced CT colonography and colonoscopy. Colonic distention was graded for different colonic segments. Two radiologists evaluated for the presence of local recurrence, metachronous disease, and metastatic disease. Results were compared with colonoscopy, histology, and clinical follow-up. RESULTS Most patients had adequate colonic inflation (37/50, 74%). Eleven of 13 patients with inadequate distention had collapse in the sigmoid colon, usually associated with ileocolic anastomoses. Contrast-enhanced CT colonography detected local recurrences with an accuracy of 94% (95% confidence interval, 83-99%). The accuracy of contrast-enhanced CT colonography for metachronous lesions greater than or equal to 1 cm was 92% (95% confidence interval, 80-98%), but there was only one such lesion, which was missed on initial colonoscopy. Stool, granulation tissue, and inflammation can mimic the CT appearance of local recurrence or metachronous disease and account for false-positive examinations. Contrast-enhanced CT colonography identified five patients with metastatic disease. CONCLUSION Suboptimal sigmoid distention can be seen on contrast-enhanced CT colonography, predominantly in patients with right hemicolectomies. Contrast-enhanced CT colonography is a promising method for detecting local recurrence, metachronous disease, and distant metastases in patients with prior invasive colorectal carcinoma. The technique can also serve as a useful adjunct to colonoscopy by detecting local recurrences or metachronous disease that are endoscopically obscure or by serving as a full structural colonic examination when endoscopy is incomplete.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic, East-2B, 200 First St., S.W., Rochester, MN 55905, USA
| | | | | | | | | | | | | | | |
Collapse
|
125
|
Abstract
In summary, technical advances in the performance of VC are occurring at a very rapid pace. These technical improvements will undoubtedly improve the polyp detection rate and reduce false-positive and false-negative examinations. The concept of VC is clearly attractive and the general public is enamored with everything that has an association with virtual reality. As other articles in this issue have revealed, there are many techniques in development to help stratify patients at risk for colon cancer. As we begin to focus our health care resources on those at highest risk, the less need there is for inexpensive, broadly based screening techniques. Clearly, those patients at high risk for having polyps are better served by colonoscopy because of its therapeutic potential. That being said, in the view of this author, if a virtual preparation can be achieved and the cost of VC can be kept relatively low, then this technique will become part of our mainstream clinical practice. If an immaculate colon preparation must be performed and if the costs reflect standard abdominal and pelvic CT rather than a special reduced cost for VC, then it is doubtful that there will be any significant impact from this technology
Collapse
Affiliation(s)
- Robert H Hawes
- Digestive Disease Center, Division of Gastroenterology and Hepatology, Medical University of South Carolina, Charleston, USA.
| |
Collapse
|
126
|
Virtual Colonoscopy for Colorectal Cancer Screening and Surveillance. COLORECTAL CANCER 2002. [DOI: 10.1007/978-1-59259-160-2_8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
127
|
Affiliation(s)
- H M Fenlon
- Department of Radiology, Mater Misericordiae Hospital, Eccles Street, Dublin 7, Ireland.
| |
Collapse
|
128
|
Abstract
Screening for colorectal cancer is commanding increasing attention. Other cancer screening programmes have been a part of public consciousness for some time, but, until recently, colorectal cancer screening has remained in the background. Fuelled by new research, market opportunities and increased recognition of individual risk, screening for colorectal cancer is becoming a recommended procedure, but controversy about how best to implement widespread screening remains.
Collapse
Affiliation(s)
- Robert E Schoen
- Division of Gastroenterology, Pennsylvania University Hospital, Pittsburgh 15213-2582, USA.
| |
Collapse
|
129
|
Yoshida H, Näppi J. Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps. IEEE TRANSACTIONS ON MEDICAL IMAGING 2001; 20:1261-1274. [PMID: 11811826 DOI: 10.1109/42.974921] [Citation(s) in RCA: 135] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We have developed a three-dimensional (3-D) computer-aided diagnosis scheme for automated detection of colonic polyps in computed tomography (CT) colonographic data sets, and assessed its performance based on colonoscopy as the gold standard. In this scheme, a thick region encompassing the entire colonic wall is extracted from an isotropic volume reconstructed from the CT images in CT colonography. Polyp candidates are detected by first computing of 3-D geometric features that characterize polyps, folds, and colonic walls at each voxel in the extracted colon, and then segmenting of connected components corresponding to suspicious regions by hysteresis thresholding based on these geometric features. We apply fuzzy clustering to these connected components to obtain the polyp candidates. False-positive (FP) detections are then reduced by computation of several 3-D volumetric features characterizing the internal structures of the polyp candidates, followed by the application of discriminant analysis to the feature space generated by these volumetric features. The locations of the polyps detected by our computerized method were compared to the gold standard of conventional colonoscopy. The performance was evaluated based on 43 clinical cases, including 12 polyps determined by colonoscopy. Our computerized scheme was shown to have the potential to detect polyps in CT colonography with a clinically acceptable high sensitivity and a low FP rate.
Collapse
MESH Headings
- Algorithms
- Cluster Analysis
- Colonic Polyps/diagnostic imaging
- Colonography, Computed Tomographic/classification
- Colonography, Computed Tomographic/methods
- Colonography, Computed Tomographic/statistics & numerical data
- Databases, Factual
- Diagnosis, Differential
- False Positive Reactions
- Humans
- Imaging, Three-Dimensional/methods
- Imaging, Three-Dimensional/statistics & numerical data
- Models, Biological
- Pattern Recognition, Automated
- ROC Curve
- Radiographic Image Interpretation, Computer-Assisted/methods
- Reproducibility of Results
- Retrospective Studies
- Sensitivity and Specificity
- Tomography, X-Ray Computed/methods
Collapse
Affiliation(s)
- H Yoshida
- Department of Radiology, The University of Chicago, IL 60637, USA.
| | | |
Collapse
|
130
|
Göktürk SB, Tomasi C, Acar B, Beaulieu CF, Paik DS, Jeffrey RB, Yee J, Napel S. A statistical 3-D pattern processing method for computer-aided detection of polyps in CT colonography. IEEE TRANSACTIONS ON MEDICAL IMAGING 2001; 20:1251-60. [PMID: 11811825 DOI: 10.1109/42.974920] [Citation(s) in RCA: 83] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Adenomatous polyps in the colon are believed to be the precursor to colorectal carcinoma, the second leading cause of cancer deaths in United States. In this paper, we propose a new method for computer-aided detection of polyps in computed tomography (CT) colonography (virtual colonoscopy), a technique in which polyps are imaged along the wall of the air-inflated, cleansed colon with X-ray CT. Initial work with computer aided detection has shown high sensitivity, but at a cost of too many false positives. We present a statistical approach that uses support vector machines to distinguish the differentiating characteristics of polyps and healthy tissue, and uses this information for the classification of the new cases. One of the main contributions of the paper is the new three-dimensional pattern processing approach, called random orthogonal shape sections method, which combines the information from many random images to generate reliable signatures of shape. The input to the proposed system is a collection of volume data from candidate polyps obtained by a high-sensitivity, low-specificity system that we developed previously. The results of our ten-fold cross-validation experiments show that, on the average, the system increases the specificity from 0.19 (0.35) to 0.69 (0.74) at a sensitivity level of 1.0 (0.95).
Collapse
MESH Headings
- Adult
- Aged
- Aged, 80 and over
- Algorithms
- Colonic Polyps/diagnostic imaging
- Colonography, Computed Tomographic/classification
- Colonography, Computed Tomographic/methods
- Colonography, Computed Tomographic/statistics & numerical data
- Diagnosis, Differential
- Female
- Humans
- Imaging, Three-Dimensional/methods
- Imaging, Three-Dimensional/statistics & numerical data
- Male
- Middle Aged
- Pattern Recognition, Automated
- ROC Curve
- Radiographic Image Interpretation, Computer-Assisted/methods
- Reproducibility of Results
- Sensitivity and Specificity
- Tomography, X-Ray Computed/methods
Collapse
Affiliation(s)
- S B Göktürk
- Department of Electrical Engineering, Stanford University, CA 94305-9010, USA.
| | | | | | | | | | | | | | | |
Collapse
|
131
|
Abstract
Virtual colonoscopy (CT colonography) promises to become a primary method for colorectal cancer screening and return radiologists to a major role in colon cancer prevention. Results from major centers in the United States show accuracy to be comparable to conventional colonoscopy for detection of polyps of significant size--that is, greater than 10 mm--with few false-positives. The advent of virtual colonoscopy has also heightened awareness of the natural history of colonic polyps, particularly in terms of identifying an appropriate target size for detection in colorectal screening programs. Small polyps (<10 mm) are often either hyperplastic on histology or are unlikely to progress to frank cancer in the patient's lifetime and are therefore of little clinical significance for the average adult. Thus, the rationale for detecting and removing each and every colonic polyp regardless of size has come under increasing scrutiny in the context of cost-benefit analysis of various test strategies for colorectal cancer screening. Virtual colonoscopy may allow patients to obtain reliable information about the status of their colonic mucosa noninvasively and thus make a more informed decision as to whether to proceed to conventional colonoscopy for polypectomy.
Collapse
Affiliation(s)
- J T Ferrucci
- Department of Radiology, Boston Medical Center, Boston University School of Medicine, 88 E. Newton St., Boston, MA 02118, USA
| |
Collapse
|
132
|
Fletcher JG, Johnson CD, Reed JE, Garry J. Feasibility of planar virtual pathology: a new paradigm in volume-rendered CT colonography. J Comput Assist Tomogr 2001; 25:864-9. [PMID: 11711796 DOI: 10.1097/00004728-200111000-00006] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Planar virtual pathology (PVP) is an isometric rendering method for examining the CT colonography dataset, which renders the colon in discrete colonic segments. Ten patients with 36 polyps were evaluated using traditional 2D axial, 2D multiplanar reformatted, and 3D endoluminal images as well as PVP. PVP displayed 13 of 17 (76%) polyps of >1 cm, whereas 11 of 17 (65%) were detected using traditional rendering methods. PVP may be a useful adjunct in detecting additional polyps at CT colonography.
Collapse
Affiliation(s)
- J G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA.
| | | | | | | |
Collapse
|
133
|
|
134
|
Abstract
CT colonography is an evolving noninvasive imaging technique that allows detection of colorectal polyps and cancers. When assessing the clinical results of this test, several points need to be emphasized. First, as computed tomography (CT) technology improves, so will clinical results. Therefore, earlier results reporting the accuracy of CT colonography may not be applicable to the current state of the art. Second, as clinical experience has grown, an understanding of the limitations and pitfalls of the technique has increased. A learning curve is involved and, with increased experience, results should improve. This article will focus on the evolving clinical results of CT colonography.
Collapse
Affiliation(s)
- M Macari
- Department of Radiology, Abdominal Imaging, New York University Medical Center, Tisch Hospital, New York 10016, USA.
| |
Collapse
|
135
|
Abstract
Computed tomography (CT) colonography provides both a multiplanar and endoluminal perspective of the air-filled, distended, cleansed colon, offering an alternative to traditional approaches to colorectal cancer screening. However, there are still limitations associated with CT colonography that need to be resolved, including inadequate bowel distention and poorly prepared colons that make it difficult to distinguish between stool and mucosal lesions including submerged polyps as well as flat or sessile polyps which can often be overlooked. In an effort to help distinguish the bowel wall and mural abnormalities from luminal contents, we have found the use of intravenous contrast material significantly improves both bowel wall conspicuity and reader confidence for examining the colon. In addition, we have found that the use of intravenous contrast material improves the diagnostic accuracy for the detection of medium and probably large polyps.
Collapse
Affiliation(s)
- M M Morrin
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215, USA.
| | | |
Collapse
|
136
|
Abstract
CT colonography (virtual colonoscopy) is a safe, noninvasive method of examining the large bowel. Since its first description in 1994, the technique has undergone rapid development, stimulating considerable interest in its potential as both a diagnostic and screening tool. Diagnostic performance statistics have been encouraging, with predictive values rivaling those of barium enema and approaching those of endoscopic colonoscopy. Improvements are underway in methods of bowel preparation, scanning procedure, and image display. Increasing experience with the technique is reflected in better understanding and characterization of both two-dimensional and three-dimensional findings, resulting in improved study performance and interpretation. This review attempts to chart the development of CT colonography, with an emphasis on published results and current research interests. We propose potential directions for future study and means toward effective implementation of CT colonography in clinical practice.
Collapse
Affiliation(s)
- J F Bruzzi
- Department of Radiology, Mater Misericordiae Hospital, Eccles Street, Dublin 7, Ireland.
| | | | | |
Collapse
|
137
|
Summers RM, Hara AK, Luboldt W, Johnson CD. Computed tomographic and magnetic resonance colonography: summary of progress from 1995 to 2000. Curr Probl Diagn Radiol 2001; 30:147-67. [PMID: 11550007 DOI: 10.1067/mdr.2001.115292] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
- R M Summers
- Diagnostic Radiology Department, Warren Grant Magnuson Clinical Center, National Institutes of Health, Bethesda, Maryland, USA
| | | | | | | |
Collapse
|
138
|
Callstrom MR, Johnson CD, Fletcher JG, Reed JE, Ahlquist DA, Harmsen WS, Tait K, Wilson LA, Corcoran KE. CT colonography without cathartic preparation: feasibility study. Radiology 2001; 219:693-8. [PMID: 11376256 DOI: 10.1148/radiology.219.3.r01jn22693] [Citation(s) in RCA: 203] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE To evaluate methods for contrast material labeling of stool in the unprepared colon for computed tomographic (CT) colonography and to determine their sensitivity for polyp detection. MATERIALS AND METHODS Fifty-six patients with suspected or known polyps were assigned to five groups. Two to seven doses of 225 mL of dilute contrast material were orally administered during 24 or 48 hours. Transverse CT images were assessed for effectiveness of stool labeling. Colonoscopy was performed in all patients and was the standard. Two radiologists blinded to prior imaging and colonoscopic results assessed polyp detection. RESULTS For each group, average stool labeling scores and ranges were as follows: 24 hour two dose, 16% and 8%-21%; 24 hour five dose, 53% and 27%-66%; 48 hour four dose, 38% and 22%-48%; 48 hour six dose, 68% and 54%-77%; and 48 hour seven dose, 88% and 75%-98%. Sensitivity for the two radiologists for the identification of patients with polyps 1 cm or larger for each group was as follows: 24 hour two dose, 50% and 67%; 24 hour five dose, 100% and 100%; 48 hour four dose, 58% and 75%; 48 hour six dose, 56% and 67%; and 48 hour seven dose, 100% and 80%. CONCLUSION Ingestion of contrast material adequately labels stool for lesion identification; a 48-hour lead time and multiple doses of contrast material are required. Sensitivity for polyp detection in patients with adequate stool labeling approaches the sensitivity for polyp detection in prepared colons.
Collapse
Affiliation(s)
- M R Callstrom
- Department of Diagnostic Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
139
|
Yee J, Akerkar GA, Hung RK, Steinauer-Gebauer AM, Wall SD, McQuaid KR. Colorectal neoplasia: performance characteristics of CT colonography for detection in 300 patients. Radiology 2001; 219:685-92. [PMID: 11376255 DOI: 10.1148/radiology.219.3.r01jn40685] [Citation(s) in RCA: 307] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE To determine the sensitivity and specificity of computed tomographic (CT) colonography for colorectal polyp and cancer detection by using colonoscopy as the reference standard. MATERIALS AND METHODS Three hundred patients underwent CT colonography followed by standard colonoscopy. Bowel preparation consisted of magnesium citrate and polyethylene glycol. After colonic air insufflation, patients underwent scanning in the supine and prone positions with 3-mm collimation during a single breath hold. The transverse CT images, sagittal and coronal reformations, and three-dimensional endoluminal images were interpreted by two radiologists independently, and then a consensus reading was performed. CT colonographic findings were correlated with standard colonoscopic and histologic findings. RESULTS The overall sensitivity and specificity of CT colonography for polyp detection were 90.1% (164 of 182) and 72.0% (85 of 118), respectively. By using direct polyp matching, the overall sensitivity was 69.7% (365 of 524). The sensitivity was 90% (74 of 82) for the detection of polyps 10 mm or larger, 80.1% (113 of 141) for polyps 5.0-9.9 mm, and 59.1% (178 of 301) for polyps smaller than 5 mm. The sensitivity was 94% (64 of 68) for the detection of adenomas 10 mm or larger, 82% (72 of 88) for adenomas 5.0-9.9 mm, and 66.9% (95 of 142) for adenomas smaller than 5 mm. CT colonography was used to identify all eight carcinomas. CONCLUSION CT colonography has excellent sensitivity for the detection of clinically important colorectal polyps and cancer.
Collapse
Affiliation(s)
- J Yee
- Department of Radiology, Veterans Affairs Medical Center, 4150 Clement St, San Francisco, CA 94121, USA.
| | | | | | | | | | | |
Collapse
|
140
|
Masutani Y, Yoshida H, MacEneaney PM, Dachman AH. Automated segmentation of colonic walls for computerized detection of polyps in CT colonography. J Comput Assist Tomogr 2001; 25:629-38. [PMID: 11473197 DOI: 10.1097/00004728-200107000-00020] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE A new method for fully automated segmentation of the colonic walls in volumetric CT data was developed for limitation of the search space in computerized detection of polyps. METHOD For reliable segmentation, an anatomy-oriented approach was used, in which several anatomical structures are segmented in addition to the colon for utilization of their properties. RESULTS The segmentation method was validated by use of 14 data sets, consisting of cases positive for colonic polyps. We found that the segmented colonic walls included all of the polyps. A subjective rating of the results was performed based on several criteria for visualization of anatomic detail of the colonic wall and mucosal surface. Except for a few cases in which insufflation of the colon was insufficient, all of the results included >95% of the colonic walls. CONCLUSION This method for colonic wall segmentation is reliable and the segmentation results are applicable in both visualization of the colon and computer-aided diagnosis in the detection of polyps in CT colonography.
Collapse
Affiliation(s)
- Y Masutani
- Kurt Rossman Laboratories for Radiologic Image Research, University of Chicago, IL 60637, USA.
| | | | | | | |
Collapse
|
141
|
Summers RM, Johnson CD, Pusanik LM, Malley JD, Youssef AM, Reed JE. Automated polyp detection at CT colonography: feasibility assessment in a human population. Radiology 2001; 219:51-9. [PMID: 11274534 DOI: 10.1148/radiology.219.1.r01ap0751] [Citation(s) in RCA: 206] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
PURPOSE To test the feasibility of and improve a computer algorithm to automatically detect colonic polyps in real human computed tomographic (CT) colonographic data sets. MATERIALS AND METHODS Twenty patients with known polyps underwent CT colonography in the supine position. CT colonographic data were processed by using a shape-based algorithm that depicts masses that protrude into the lumen. We studied nine shape criteria and three isosurface threshold settings. Results were compared with those of conventional colonoscopy performed the same day. RESULTS There were 50 polyps (28 were > or =10 mm in size; 12, 5-9 mm; 10, <5 mm). The sensitivity with optimal settings for detecting polyps 10 mm or greater was 64% (18 of 28). Sensitivity improved to 71% (10 of 14) for polyps 10 mm or greater in well-distended colonic segments. Performance decreased for polyps less than 10 mm, poorly distended colonic segments, and other shape algorithms. There was a mean of six false-positive lesion sites per colon. These sites were reduced 39% to 3.5 per colon by sampling CT attenuation at the lesion site and discarding sites having attenuation less than a threshold. CONCLUSION Automated detection of colonic polyps, especially clinically important large polyps, is feasible. Colonic distention is an important determinant of sensitivity. Further increases in sensitivity may be achieved by adding prone CT colonography.
Collapse
Affiliation(s)
- R M Summers
- Diagnostic Radiology Department, Warren Grant Magnuson Clinical Center, National Institutes of Health, Bldg 10, Rm 1C660, 10 Center Dr, MSC 1182, Bethesda, MD 20892-1182, USA
| | | | | | | | | | | |
Collapse
|
142
|
Abstract
Advances in computed tomography (CT) technology and computer capabilities have contributed to the development of a new imaging modality for colorectal lesions called CT colonography or virtual colonoscopy. Virtual colonoscopy is a rapid, minimally invasive scan of the cleansed and distended colon. Early work has demonstrated that this test is safe and well tolerated, and that it may be sensitive and specific enough to identify most significant precancerous or cancerous lesions. A number of technical and practical problems remain before virtual colonoscopy can be applied at a population level.
Collapse
Affiliation(s)
- D T Rubin
- Section of Gastroenterology, Department of Medicine, University of Chicago, 5841 South Maryland Avenue, Chicago, IL 60637-1470, USA.
| | | |
Collapse
|
143
|
McFarland EG, Brink JA, Pilgram TK, Heiken JP, Balfe DM, Hirselj DA, Weinstock L, Littenberg B. Spiral CT colonography: reader agreement and diagnostic performance with two- and three-dimensional image-display techniques. Radiology 2001; 218:375-83. [PMID: 11161149 DOI: 10.1148/radiology.218.2.r01ja47375] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
PURPOSE To assess the diagnostic performance and reader agreement with two-dimensional (2D) and three-dimensional (3D) display techniques for detecting colorectal polyps with spiral computed tomographic (CT) colonography. MATERIALS AND METHODS A test set of 30 colonic segments was developed from spiral CT colonographic studies (12 with polyps and 18 without). The 12 segments with polyps contained 22 lesions (11 polyps <10 mm, 11 polyps or cancers >/=10 mm), with all findings verified with colonoscopy. Three specific 2D and 3D image-display techniques were tested. Three experienced abdominal radiologists independently analyzed each test case and were retested 6 weeks later. RESULTS The results of readings 1 and 2 were similar for all image-display techniques among the readers. Pooled segment results were sensitivity of 89%-92% and specificity of 72%-83%. Pooled polyp size results for sensitivity and positive predictive value were 77%-86% and 74%-86% (all polyps, n = 22), 91%-100% and 85%-100% (polyps or cancers >10 mm, n = 11), and 61%-73% and 61%-80% (polyps 5-9 mm, n = 11), respectively. Overall intraobserver agreement was good for the three display techniques (kappa, 0.60-1.00); however, interobserver agreement for 2D multiplanar reformation was lower (kappa, 0.53-0.80). CONCLUSION Among experienced abdominal radiologists, similar diagnostic performance in polyp detection was found among 2D multiplanar reformation and 3D display techniques, although individual cases showed improved characterization with 3D display techniques. Evaluation of reader agreement demonstrated good intraobserver agreement, with variable interobserver agreement.
Collapse
Affiliation(s)
- E G McFarland
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110, USA.
| | | | | | | | | | | | | | | |
Collapse
|
144
|
Britton I, Dover S, Vallance R. Immediate CT pneumocolon for failed colonoscopy; comparison with routine pneumocolon. Clin Radiol 2001; 56:89-93. [PMID: 11222063 DOI: 10.1053/crad.2000.0559] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
AIM To assess the role and reliability of 2D CT pneumocolon in the diagnosis of colonic malignancy, and compare feasibility of referral sources. MATERIALS AND METHODS A prospective study of 50 patients with suspected large bowel malignancy. Patients underwent bowel cleansing, rectal air insufflation and contrast enhanced CT with 5 mm collimation, 3 mm reconstruction and a pitch of 1.4. Subsequent correlation was with pathology (16), colonoscopy (13), barium enema (5), ERCP (1) and clinical follow-up alone (8). RESULTS Diagnostic images were obtained in 43/50 patients (86% feasibility). Follow-up was obtained in 35/43 patients (one patient died of an unrelated cause, and seven patients were deemed unfit for further investigation). Seventeen colonic carcinomas were diagnosed (three false-positives: one ischaemic colitis, one diverticular stricture and one faecal mass), one diverticular stricture, one fistula, one pancreatic carcinoma and one ovarian malignancy. The remaining 14 were negative. Overall sensitivity was 100% (for lesions >1.5 cm) with a specificity of 94% for structural abnormalities, but only 82% for the correct identification of malignancy. CONCLUSION Computed tomography (CT) pneumocolon is a reliable alternative to barium enema where colonoscopy is incomplete, with the advantage of extraluminal screening, and examination of the proximal bowel. In the frail elderly or young unfit patient, it is a valuable additional diagnostic tool.
Collapse
Affiliation(s)
- I Britton
- Department of Radiology, Pilgrim Hospital, Sibsey Road, Boston, UK.
| | | | | |
Collapse
|
145
|
Abstract
CT has now come of age in the detection and demonstration of bowel pathology and is likely to supplant traditional imaging techniques further in the future. Its role here has been greatly aided by the advent of fast spiral CT sequences and, with the development of even faster multidetector CT systems, this can only increase.
Collapse
Affiliation(s)
- A H Freeman
- Department of Radiology, Addenbrooke's Hospital, Hills Road, Cambridge CB2 2QQ, UK
| |
Collapse
|
146
|
Macari M, Lavelle M, Pedrosa I, Milano A, Dicker M, Megibow AJ, Xue X. Effect of different bowel preparations on residual fluid at CT colonography. Radiology 2001; 218:274-7. [PMID: 11152814 DOI: 10.1148/radiology.218.1.r01ja31274] [Citation(s) in RCA: 128] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The effect of different bowel preparations on residual fluid during computed tomographic (CT) colonography was evaluated. Forty-two patients received either a polyethylene glycol electrolyte solution preparation or a phospho-soda preparation the day prior to CT colonography. The amount of residual fluid was calculated for each patient. On average, a phospho-soda preparation provided significantly less residual fluid than a polyethylene glycol electrolyte solution preparation.
Collapse
Affiliation(s)
- M Macari
- Department of Radiology, Division of Abdominal Imaging, New York University Medical Center, Tisch Hospital, New York, NY 10016, USA.
| | | | | | | | | | | | | |
Collapse
|
147
|
Macari M, Megibow AJ. Pitfalls of using three-dimensional CT colonography with two-dimensional imaging correlation. AJR Am J Roentgenol 2001; 176:137-43. [PMID: 11133553 DOI: 10.2214/ajr.176.1.1760137] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Affiliation(s)
- M Macari
- Department of Radiology, Abdominal Imaging, NYU Medical Center, Tisch Hospital, 560 First Ave., Ste. HW 206, New York, NY 10016, USA
| | | |
Collapse
|
148
|
Abstract
Virtual colonoscopy or computed-tomography colonography is a promising new method for colorectal cancer screening. Helical computed tomography is used to generate high-resolution, two-dimensional axial images of the abdomen and pelvis. Three-dimensional images of the colon simulating those obtained with conventional colonoscopy can be reconstructed from the data obtained. Favorable attributes of virtual colonoscopy include its safety, high patient acceptance, and ability to provide a full structural evaluation of the entire colon. Multiple studies of virtual colonoscopy have been published in the literature in the past year regarding technique, image display, image reconstruction, clinical trial results, and feasibility as a screening tool. This manuscript will review the various studies in each of these areas.
Collapse
Affiliation(s)
- A S Chaoui
- Department of Radiology, Boston University School of Medicine, Boston Medical Center, Boston, Massachusetts 02118, USA.
| | | |
Collapse
|
149
|
Morrin MM, Farrell RJ, Kruskal JB, Reynolds K, McGee JB, Raptopoulos V. Utility of intravenously administered contrast material at CT colonography. Radiology 2000; 217:765-71. [PMID: 11110941 DOI: 10.1148/radiology.217.3.r00nv42765] [Citation(s) in RCA: 159] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
PURPOSE To determine if intravenously administered contrast material improves overall reader confidence in the assessment of the colon, large-bowel wall conspicuity, and diagnostic accuracy in the detection of colorectal polyps and cancers at computed tomographic (CT) colonography. MATERIALS AND METHODS Two hundred patients underwent CT colonography in both supine and prone positions. A five-point scale was used to assess the effect of contrast enhancement on overall reader confidence and bowel wall conspicuity. Eighty-one patients underwent CT colonography with complete colonoscopic or surgical correlation; diagnostic accuracy was compared in 48 patients who received contrast material and 33 who did not. RESULTS Bowel preparation was ideal in 38 (19%) of 200 patients. Enhanced prone CT images had significantly better scores for reader confidence (4.9 +/- 0.1 vs 4.6 +/- 0.1, P: <.005) and bowel wall conspicuity (4.6 +/- 0.2 vs 4.2 +/- 0.2, P: <.005) compared with those of nonenhanced prone images despite no significant difference in bowel distention (3.8 +/- 0.2 vs 3.9 +/- 0. 1, P: =.8). Enhancement significantly improved the ability to depict medium (6-9-mm) polyps (75% vs 58%, P: <.05). Three large (10-19-mm) polyps were detected only with contrast enhancement; two remained submerged despite dual positioning. CONCLUSION The use of intravenously administered contrast material significantly improved reader confidence in the assessment of bowel wall conspicuity and the ability of CT colonography to depict medium polyps in suboptimally prepared colons.
Collapse
Affiliation(s)
- M M Morrin
- Departments of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, Boston MA 02215, USA.
| | | | | | | | | | | |
Collapse
|
150
|
Murray D, Hellawell G, Oakley R, Rosenfeld K, Al-Mufti RA, Lewis AA, Berger LA. Should air contrast computed tomography become the first investigation of the colon of frail or elderly patients? Colorectal Dis 2000; 2:330-5. [PMID: 23578150 DOI: 10.1046/j.1463-1318.2000.00143.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVE Air contrast computed tomography (ACCT) is an alternative test to barium enema or colonoscopy. We review our experience of this test as the first investigation of frail, elderly patients with lower gastrointestinal symptoms, and record the subsequent clinical course of these patients to evaluate the efficacy of the technique. PATIENTS AND METHODS We performed 109 ACCT studies on frail patients aged 70 years or over with lower gastrointestinal symptoms. The findings were correlated with subsequent investigations and surgical findings. Patients with normal scans were followed up in out-patients or by their GP. Average follow up was 17 months. RESULTS A good quality complete examination of the colon was achieved in 97% of patients. Of 109 examinations 34 (31%) were reported as normal, 65 (60%) as diverticular disease, nine (8%) as demonstrating a colonic malignancy and one (1%) showed a benign polyp. One sigmoid tumour was missed initially but diagnosed on a repeat ACCT study. CONCLUSION ACCT is a reliable, well-tolerated technique in elderly frail patients.
Collapse
Affiliation(s)
- D Murray
- Department of Radiology, Royal Free Hospital, London, UK Department of Surgery, Royal Free Hospital, London, UK
| | | | | | | | | | | | | |
Collapse
|