151
|
Diagnostic accuracy of ultrasound-guided attenuation parameter as a noninvasive test for steatosis in non-alcoholic fatty liver disease. J Med Ultrason (2001) 2021; 48:471-480. [PMID: 34415481 DOI: 10.1007/s10396-021-01123-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Accepted: 07/09/2021] [Indexed: 10/20/2022]
Abstract
The purpose of this study was to evaluate the diagnostic accuracy of the ultrasound-guided attenuation parameter (UGAP) using the LOGEQ E10 for hepatic steatosis in non-alcoholic fatty liver disease (NAFLD) patients and directly compare UGAP with attenuation imaging (ATI) and controlled attenuation parameter (CAP). We prospectively analyzed 105 consecutive patients with NAFLD who underwent UGAP, ATI, CAP, and liver biopsy on the same day between October 2019 and April 2021. The diagnostic ability of the UGAP-determined attenuation coefficient (AC) was evaluated using receiver operating characteristic (ROC) curve analysis, and its correlation with ATI-determined AC values or CAP values was investigated. The success rate of UGAP was 100%. The median IQR/med obtained by UGAP was 4.0%, which was lower than that of ATI and CAP (P < 0.0001). The median ACs obtained by UGAP for grades S0 (control), S1, S2, and S3 were 0.590, 0.670, 0.750, and 0.845 dB/cm/MHz, respectively, demonstrating a stepwise increase with increasing hepatic steatosis severity (P < 0.0001). The areas under the ROC curve of UGAP for identifying ≥ S1, ≥ S2, and S3 were 0.890, 0.906, and 0.912, respectively, which were significantly better than the results obtained with CAP for identifying S3. Furthermore, the correlation coefficient between UGAP-AC and ATI-AC values was 0.803 (P < 0.0001), indicating a strong relationship. Our results indicate that UGAP has high diagnostic accuracy for detecting and grading hepatic steatosis in patients with NAFLD.
Collapse
|
152
|
Hwang J, Yoon HM, Kim KM, Oh SH, Namgoong JM, Kim DY, Cho YA. Assessment of native liver fibrosis using ultrasound elastography and serological fibrosis indices in children with biliary atresia after the Kasai procedure. Acta Radiol 2021; 62:1088-1096. [PMID: 32811156 DOI: 10.1177/0284185120948489] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Validated non-invasive examinations are necessary to monitor liver fibrosis in children with biliary atresia (BA) after the Kasai procedure. PURPOSE To evaluate the diagnostic accuracy of two-dimensional shear wave elastography (2D-SWE), transient elastography (TE), and the serologic biomarkers of aspartate transaminase-to-platelet ratio index (APRI) and Fibrosis-4 (FIB-4) score for evaluating native liver fibrosis in children with BA. MATERIAL AND METHODS We retrospectively reviewed same-day 2D-SWE and TE liver stiffness (LS) measurements of 63 patients with BA who underwent the Kasai procedure. The APRI and FIB-4 score were computed. Hepatic fibrosis was categorized into three clinical categories based on the ultrasound (US) hepatic morphology and clinical manifestations of liver cirrhosis: I, pre-cirrhotic liver state (n = 15); II, US and/or clinical signs of liver cirrhosis with compensated liver function (n = 27); and III, liver cirrhosis with decompensated liver function (n = 21). We compared area under the receiver operating characteristic curve (AUC) data among 2D-SWE, TE, APRI, and FIB-4 score. Combined evaluation of serologic fibrosis indices and US elastography was conducted and AUCs of combinations were analyzed. RESULTS 2D-SWE, TE, APRI, and FIB-4 score showed good to excellent diagnostic accuracy for differentiating clinical categories (AUCs 0.779-0.955). AUC values were significantly increased after adding TE to FIB-4 score for detecting liver cirrhosis (P = 0.02). CONCLUSION 2D-SWE, TE, APRI, and FIB-4 score are accurate non-invasive markers for monitoring native liver fibrosis in patients with BA. Combined use of serologic markers and US elastography could yield more accurate diagnoses of liver fibrosis than serologic markers alone.
Collapse
Affiliation(s)
- Jisun Hwang
- Department of Radiology, Dongtan Sacred Heart Hospital, Hallym University Medical Center, Hwaseong, Republic of Korea
| | - Hee Mang Yoon
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Kyung Mo Kim
- Department of Pediatrics, Asan Medical Center Children's Hospital, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Seak Hee Oh
- Department of Pediatrics, Asan Medical Center Children's Hospital, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Jung-Man Namgoong
- Department of Pediatric Surgery, Asan Medical Center Children's Hospital, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Dae Yeon Kim
- Department of Pediatric Surgery, Asan Medical Center Children's Hospital, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Young Ah Cho
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
153
|
Yang J, Li J, Ye G, Luo Y. Comparison of Visual Transient Elastography and Shear Wave Elastography in Evaluating Liver Fibrosis in Patients with Chronic Liver Disease. Int J Gen Med 2021; 14:3553-3561. [PMID: 34295181 PMCID: PMC8290848 DOI: 10.2147/ijgm.s319101] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 06/30/2021] [Indexed: 02/05/2023] Open
Abstract
Purpose This study investigated the effectiveness and feasibility of shear wave elastography ((sound touch elastography) STE and (shear wave elastography) SWE) and visual transient elastography (ViTE) in the noninvasive quantitative diagnosis of liver fibrosis in chronic liver disease (CLD). Patients and Methods A total of 106 patients with CLD underwent STE, SWE and ViTE elastography evaluation. The Young’s modulus of the three elastography was valuated and the diagnostic performances of the three techniques for liver fibrosis staging were compared. The area under the receiver operating curve (ROC) for the diagnosis of liver fibrosis was compared. The final diagnosis was based on the histological findings on the liver biopsy. Results 1) The correlation between ViTE and SWE, ViTE and STE, SWE and STE stiffness values were 0.72, 0.75, 0.75 (P<0.001). 2) The relationship between the results of each elastography technique and the stage of pathological liver fibrosis showed that the more severe the liver fibrosis was, the higher the stiffness value was (all P <0.001). 3) When the three elastography techniques were used to detect the degree of liver fibrosis in different pathological stages, there was no statistical difference in the stabilities of the boxplots. 4) The ROCs of the three elastography techniques (ViTE, SWE and STE) were 0.88, 0.91, 0.92, F0 vs F1-3; 0.84, 0.84, 0.84, F0-1 vs F2-4; 0.80, 0.79, 0.77, F0-2 vs F3-4; 0.80, 0.76, 0.71, F0-3 vs 4; the AUC of ViTE was higher than the AUC of STE in the identification of F4, but there were no statistical differences in the AUCs of other groups. Conclusion ViTE has good stability for the liver stiffness measurement (LSM) and a high consistency with shear-wave elastography (SWE and STE). It is an effective tool for evaluating CLD, and its performance is comparable to SWE and STE. The combination of ViTE and STE can improve the specificity of disease diagnosis and do not add extra cost and may improve cost performance.
Collapse
Affiliation(s)
- Jiali Yang
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China
| | - Jiawu Li
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China
| | - Guilin Ye
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China
| | - Yan Luo
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China
| |
Collapse
|
154
|
Popa A, Șirli R, Popescu A, Bâldea V, Lupușoru R, Bende F, Cotrău R, Sporea I. Ultrasound-Based Quantification of Fibrosis and Steatosis with a New Software Considering Transient Elastography as Reference in Patients with Chronic Liver Diseases. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1692-1703. [PMID: 33832824 DOI: 10.1016/j.ultrasmedbio.2021.02.029] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 01/30/2021] [Accepted: 02/23/2021] [Indexed: 06/12/2023]
Abstract
The goal of this study was to evaluate the performance of two new ultrasound-based techniques (ShearWave PLUS elastography [2-D-SWE PLUS], SSp PLUS Imaging [SSp PLUS]) implemented on the Aixplorer Mach 30 ultrasound system (Supersonic Imagine, Aix-en-Provence, France) for the non-invasive assessment of liver steatosis and fibrosis, using transient elastography (TE) with the controlled attenuation parameter (CAP) as reference. This monocentric cross-sectional study included 133 consecutive adult patients with chronic hepatopathies. Liver stiffness and steatosis were evaluated in the same session using the techniques mentioned above. An excellent correlation was observed between liver stiffness measurements obtained with 2-D-SWE PLUS and TE (r = 0.92, p < 0.0001). The best cutoff value of 2-D-SWE PLUS for predicting F≥2 was 6.8 kPa; for F≥3, 8.4 kPa; and for F4, 11 kPa. With respect to steatosis evaluation, a strong negative correlation between CAP and SSp PLUS values (r = -0.70, p < 0.0001) was obtained. The best SSp PLUS cutoff value for predicting steatosis was 1537 m/s.
Collapse
Affiliation(s)
- Alexandru Popa
- Department of Gastroenterology and Hepatology, ''Victor Babeș'' University of Medicine and Pharmacy, Timișoara, România
| | - Roxana Șirli
- Department of Gastroenterology and Hepatology, ''Victor Babeș'' University of Medicine and Pharmacy, Timișoara, România
| | - Alina Popescu
- Department of Gastroenterology and Hepatology, ''Victor Babeș'' University of Medicine and Pharmacy, Timișoara, România
| | - Victor Bâldea
- Department of Gastroenterology and Hepatology, ''Victor Babeș'' University of Medicine and Pharmacy, Timișoara, România.
| | - Raluca Lupușoru
- Department of Gastroenterology and Hepatology, ''Victor Babeș'' University of Medicine and Pharmacy, Timișoara, România; Department of Functional Science, "Victor Babeș" University of Medicine and Pharmacy Timișoara, Romania
| | - Felix Bende
- Department of Gastroenterology and Hepatology, ''Victor Babeș'' University of Medicine and Pharmacy, Timișoara, România
| | - Radu Cotrău
- Department of Gastroenterology and Hepatology, ''Victor Babeș'' University of Medicine and Pharmacy, Timișoara, România
| | - Ioan Sporea
- Department of Gastroenterology and Hepatology, ''Victor Babeș'' University of Medicine and Pharmacy, Timișoara, România
| |
Collapse
|
155
|
Tamura M, Ohta H, Osuga T, Sasaki N, Morishita K, Takiguchi M. Extrahepatic biliary obstruction can interfere with hepatic fibrosis prediction using two-dimensional shear wave elastography in dogs. Vet Radiol Ultrasound 2021; 62:483-489. [PMID: 33855776 DOI: 10.1111/vru.12969] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 12/25/2020] [Accepted: 02/09/2021] [Indexed: 12/20/2022] Open
Abstract
Two-dimensional shear wave elastography (2D-SWE) can be used to quantitatively evaluate the elastic modulus of the liver as shear wave velocity (SWV), which can noninvasively predict clinically relevant hepatic fibrosis in both dogs and humans. However, extrahepatic biliary obstruction (EHBO), regardless of the presence of clinically relevant hepatic fibrosis, can influence SWVs in humans and thus may interfere with hepatic fibrosis prediction using 2D-SWE in dogs. The aim of this prospective, observational, and one-group pretest-posttest study is to investigate whether SWV measured by 2D-SWE displays a difference between dogs with and without EHBO. A total of 20 dogs were included (7 with EHBO and 13 with gallbladder pathology but no EHBO) that underwent preoperative SWV measurement using 2D-SWE. In all dogs, stages of hepatic fibrosis were evaluated histopathologically using a scoring scheme. In addition, postoperative SWVs in dogs with EHBO relieved via laparotomy were also evaluated. The median (range) SWVs in the dogs with and without EHBO were 1.91 (1.81-2.54) m/s and 1.57 (1.37-1.64) m/s, respectively. Although there was no significant difference in the histopathological hepatic fibrosis stages between the dogs with and without EHBO, the preoperative SWVs in the dogs with EHBO were significantly higher than in dogs without EHBO (P = .0004), and SWVs were found to decrease significantly after surgery (P = .0097). This study demonstrates that EHBO can increase the SWV of dogs without clinically relevant hepatic fibrosis and can interfere with the prediction of noninvasive hepatic fibrosis using 2D-SWE.
Collapse
Affiliation(s)
- Masahiro Tamura
- Veterinary Teaching Hospital, Graduate school of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Hiroshi Ohta
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Hokkaido, Japan
| | - Tatsuyuki Osuga
- Veterinary Teaching Hospital, Graduate school of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Noboru Sasaki
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Hokkaido, Japan
| | - Keitaro Morishita
- Veterinary Teaching Hospital, Graduate school of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Mitsuyoshi Takiguchi
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Hokkaido, Japan
| |
Collapse
|
156
|
Application of ultrasound elastography for monitoring the effects of TβR1 shRNA therapy on hepatic fibrosis in a rat model. PLoS One 2021; 16:e0253150. [PMID: 34181670 PMCID: PMC8238185 DOI: 10.1371/journal.pone.0253150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 05/29/2021] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND To investigate the application of ultrasound elastography in monitoring the effects of the transforming growth factor (TGF)-β1 signaling pathway-targeted combination therapy for hepatic fibrosis. METHODS 1. Short hairpin RNA (shRNA) constructs targeted towards TβR1 were designed, synthesized, and packaged using an adeno-associated virus (AAV), and the effective target shRNA was selected based on transfection results. 2. Fifty rats were randomly allocated (n = 10 per group) to the (A) control group, (B) model group, (C) 0-week therapy group, (D) 4-week therapy group, and (E) combination therapy group. At weeks 2, 4, 6, 8, 10, and 12, acoustic radiation force impulse (ARFI) elastography was used to measure the liver stiffness, inner diameter of the portal vein diameter, and blood velocity; radio frequency ultrasound imaging was used to measure the abdominal aortic elasticity parameter and pulse wave velocity (PWV) of the rats. 3. At week 12, portal vein puncture was performed to measure the portal venous pressure, and rat liver specimens were obtained for the pathological measurement of the degree of hepatic fibrosis. RESULTS 1. An shRNA interference sequence targeted towards TβR1 was successfully designed, screened, and packaged using an AAV, and small-animal imaging results indicated expression of the specific shRNA in the liver. 2. At week 12, the ultrasound elastography results were significantly different between the experimental groups and the control group (p < 0.01); among the experimental groups, differences were significant between the therapy groups and the model group (p < 0.01). For groups C and E, the therapeutic effects on hepatic fibrosis in rats were significant, with the pathological results indicating a significant reduction in the degree of hepatic fibrosis (p < 0.01). The therapeutic effectiveness of group D was less than that of group C (p < 0.05). Significant differences existed between the portal venous pressure of the experimental groups and of the control group (p < 0.01). For the abdominal aortic elasticity parameter measured by radio frequency ultrasound imaging, differences existed between the values obtained from the experimental groups and from that of the control group (p < 0.05), while statistically significant differences were not found among the various experimental groups. 3. Continuous ultrasound examination results indicated that the elasticity value of group A was significantly different from those of the other groups after 2 weeks of model establishment (p < 0.01); after 6 weeks, the elasticity values of groups C and E were significantly different compared with those of groups B and D (p < 0.01). For the abdominal aortic elasticity parameter and pulse wave velocity (PWV), there were no significant differences among the various groups (p > 0.05). CONCLUSION CCl4-induced hepatic fibrosis can be treated through shRNA silencing of TβR1. Ultrasound ARFI elastography is superior to external force-assisted elastography as it can reflect the degree of fibrosis in moderate to severe hepatic fibrosis and the variations in the degree of fibrosis after treatment. Portal venous pressure was positively correlated with the degree of fibrosis; with early combination therapy, both the degree of fibrosis and portal venous pressure could be effectively reduced.
Collapse
|
157
|
Florea M, Serban T, Tirpe GR, Tirpe A, Lupsor-Platon M. Noninvasive Assessment of Hepatitis C Virus Infected Patients Using Vibration-Controlled Transient Elastography. J Clin Med 2021; 10:jcm10122575. [PMID: 34200885 PMCID: PMC8230562 DOI: 10.3390/jcm10122575] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 06/06/2021] [Accepted: 06/08/2021] [Indexed: 02/08/2023] Open
Abstract
Chronic infection with hepatitis C virus (HCV) is one of the leading causes of cirrhosis and hepatocellular carcinoma (HCC). Surveillance of these patients is an essential strategy in the prevention chain, including in the pre/post-antiviral treatment states. Ultrasound elastography techniques are emerging as key methods in the assessment of liver diseases, with a number of advantages such as their rapid, noninvasive, and cost-effective characters. The present paper critically reviews the performance of vibration-controlled transient elastography (VCTE) in the assessment of HCV patients. VCTE measures liver stiffness (LS) and the ultrasonic attenuation through the embedded controlled attenuation parameter (CAP), providing the clinician with a tool for assessing fibrosis, cirrhosis, and steatosis in a noninvasive manner. Moreover, standardized LS values enable proper staging of the underlying fibrosis, leading to an accurate identification of a subset of HCV patients that present a high risk for complications. In addition, VCTE is a valuable technique in evaluating liver fibrosis prior to HCV therapy. However, its applicability in monitoring fibrosis regression after HCV eradication is currently limited and further studies should focus on extending the boundaries of VCTE in this context. From a different perspective, VCTE may be effective in identifying clinically significant portal hypertension (CSPH). An emerging prospect of clinical significance that warrants further study is the identification of esophageal varices. Our opinion is that the advantages of VCTE currently outweigh those of other surveillance methods.
Collapse
Affiliation(s)
- Mira Florea
- Community Medicine Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania;
| | - Teodora Serban
- Medical Imaging Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania;
| | - George Razvan Tirpe
- Department of Radiology and Medical Imaging, County Emergency Hospital Cluj-Napoca, 3-5 Clinicilor Street, 400000 Cluj-Napoca, Romania;
| | - Alexandru Tirpe
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, 23 Marinescu Street, 400337 Cluj-Napoca, Romania;
| | - Monica Lupsor-Platon
- Medical Imaging Department, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania;
- Medical Imaging Department, Regional Institute of Gastroenterology and Hepatology, 400162 Cluj-Napoca, Romania
- Correspondence:
| |
Collapse
|
158
|
Kitano M, Yamashita Y, Kamata K, Ang TL, Imazu H, Ohno E, Hirooka Y, Fusaroli P, Seo DW, Napoléon B, Teoh AYB, Kim TH, Dietrich CF, Wang HP, Kudo M. The Asian Federation of Societies for Ultrasound in Medicine and Biology (AFSUMB) Guidelines for Contrast-Enhanced Endoscopic Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1433-1447. [PMID: 33653627 DOI: 10.1016/j.ultrasmedbio.2021.01.030] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 01/25/2021] [Accepted: 01/28/2021] [Indexed: 06/12/2023]
Abstract
The Asian Federation of Societies for Ultrasound in Medicine and Biology aimed to provide information on techniques and indications for contrast-enhanced harmonic endoscopic ultrasound (CH-EUS), and to create statements including the level of recommendation. These statements are based on current scientific evidence reviewed by a Consensus Panel of 15 internationally renowned experts. The reliability of clinical questions was measured by agreement rates after voting. Six statements were made on techniques, including suitable contrast agents for CH-EUS, differences between contrast agents, setting of mechanical index, dual imaging and duration and phases for observation. Thirteen statements were made on indications, including pancreatic solid masses, pancreatic cancer staging, pancreatic cystic lesions and mural nodules, detection of subtle pancreatic lesions, gallbladder sludge and polyps, hepatic lesions, lymph nodes, subepithelial lesions, visceral vascular diseases, guidance of fine needle aspiration and evaluation for local therapy. These international expert consensus guidelines will assist endosonographers in conducting CH-EUS according to evidence-based information.
Collapse
Affiliation(s)
- Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan.
| | - Yasunobu Yamashita
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Ken Kamata
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan
| | - Tiing Leong Ang
- Department of Gastroenterology and Hepatology, Changi General Hospital, Singapore
| | - Hiroo Imazu
- Division of Gastroenterology and Hepatology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Eizaburo Ohno
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School, Nagoya, Japan
| | - Yoshiki Hirooka
- Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University, Aichi, Japan
| | - Pietro Fusaroli
- Gastroenterology Unit, Department of Medical and Surgical Sciences, University of Bologna/Hospital of Imola, Imola, Italy
| | - Dong-Wan Seo
- Department of Gastroenterology, Asan Medical Centre, Seoul, Korea
| | - Bertrand Napoléon
- Department of Gastroenterology, Jean Mermoz Private Hospital, Ramsay Generale de Sante, Lyon, France
| | - Anthony Yuen Bun Teoh
- Department of Surgery, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong, China
| | - Tae Hyeon Kim
- Department of Internal Medicine, Wonkwang University College of Medicine, Iksan, South Korea
| | - Christoph F Dietrich
- Department of Internal Medicine (DAIM), Hirslanden Kliniken Beau Site, Salem und Permanence Bern, Switzerland
| | - Hsiu-Po Wang
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan
| |
Collapse
|
159
|
Hirooka M, Koizumi Y, Yano R, Sunago K, Watanabe T, Yoshida O, Tokumoto Y, Abe M, Hiasa Y. Validation of the FibroScan-aspartate aminotransferase score by vibration-controlled transient and B-mode ultrasound elastography. Hepatol Res 2021; 51:652-661. [PMID: 33877727 DOI: 10.1111/hepr.13646] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 03/29/2021] [Accepted: 04/08/2021] [Indexed: 01/05/2023]
Abstract
AIM The FibroScan-aspartate aminotransferase (FAST) score comprises an easy and feasible method for identifying advanced non-alcoholic steatohepatitis. Recently, shear-wave elastography and attenuation coefficient measurement on B-mode ultrasound (US) have become widely utilized. We investigated the diagnostic accuracy of the FAST score as calculated using US-elastography compared with that using vibration-controlled transient elastography (VCTE). METHODS Patients with chronic liver disease who underwent VCTE, point-shear-wave elastography with attenuation coefficient measurement, and liver biopsy on the same day between January 2015 and September 2020 were retrospectively reviewed. RESULTS Of 189 patients, 94 underwent VCTE using both M and XL probes. The C-statistics were similar for VCTE (0.846) and US-elastography (0.814; p = 0.251), and for M (0.857) and XL probes (0.833; p = 0.412). Scatter and Bland-Altman plots showed good reproducibility for the FAST score. For VCTE, a cut-off of ≤0.35 had a sensitivity of 92.3%, negative predictive value of 85.5%, and negative likelihood ratio of 0.14, and a cut-off of ≥0.67 had a specificity of 90.6%, positive predictive value of 88.1%, and positive likelihood ratio of 6.03, for ruling out and in advanced non-alcoholic steatohepatitis, respectively. For US-elastography, a cut-off of ≤0.35 had a sensitivity of 90.4%, negative predictive value of 83.3%, and negative likelihood ratio of 0.16, and a cutoff of ≥0.67 had a specificity of 91.8%, positive predictive value of 85.1%, and positive likelihood ratio of 4.67, for ruling out and in advanced non-alcoholic steatohepatitis, respectively. CONCLUSIONS The FAST score is highly reproducible, even when different echo equipment or probes are used.
Collapse
Affiliation(s)
- Masashi Hirooka
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| | - Yohei Koizumi
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| | - Ryo Yano
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| | - Kotarou Sunago
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| | - Takao Watanabe
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| | - Osamu Yoshida
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| | - Yoshio Tokumoto
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| | - Masanori Abe
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| | - Yoichi Hiasa
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Touon, Ehime, Japan
| |
Collapse
|
160
|
Dong BT, Huang S, Lyu GR, Qin R, Gu JH. Assessment of liver fibrosis with liver and spleen stiffness measured by sound touch elastography, serum fibrosis markers in patients with chronic hepatitis B. J Dig Dis 2021; 22:342-350. [PMID: 33851510 DOI: 10.1111/1751-2980.12991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 04/07/2021] [Accepted: 04/11/2021] [Indexed: 12/11/2022]
Abstract
OBJECTIVES To evaluate the performance of liver stiffness (LS) and spleen stiffness (SS) by using the sound touch elastography (STE) technique and compare with those of the splenic index, aspartate transaminase-to-platelet ratio index (APRI), fibrosis-4 (FIB-4) index, King's score and combined models for diagnosing and staging fibrosis in chronic hepatitis B (CHB). METHODS One hundred patients with CHB underwent STE and serological tests. LS and SS values were measured with STE technique, and splenic index was calculated. Staging of fibrosis was determined with liver biopsy. Correlations between the individual parameters and the stage of fibrosis were evaluated with the Spearman correlation analysis. The area under the receiver operating characteristic curve (AUROC) was calculated to analyze the performance of all methods. RESULTS Among all individual parameters, LS showed the highest AUROC for diagnosing fibrosis of ≥S2, ≥S3, and S4 stages (AUROC: 0.70, 0.86, and 0.96, respectively; all P < 0.05). The AUROC of combined model 1 (LS and SS) and 2 (LS, SS, APRI, FIB-4 index, King's score) for diagnosing ≥S2, ≥S3, and S4 fibrosis were 0.70, 0.86, 0.97, and 0.70, 0.86, 0.96, respectively, which were higher than those of APRI, FIB-4 index and the King's score (P < 0.05). No significant differences were found between two combined models and LS for staging fibrosis (P > 0.05). CONCLUSIONS LS measurement is reliable for diagnosing and staging fibrosis in CHB, with a better performance than SS, splenic index and serum biomarkers. It is also comparable with the performance of combined models.
Collapse
Affiliation(s)
- Bing Tian Dong
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China
| | - Shu Huang
- Department of Ultrasound, Chenggong Hospital Affiliated to Xiamen University, Xiamen, Fujian Province, China
| | - Guo Rong Lyu
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China
| | - Ran Qin
- Department of Ultrasound, Chenggong Hospital Affiliated to Xiamen University, Xiamen, Fujian Province, China
| | - Jiong Hui Gu
- Department of Ultrasound, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| |
Collapse
|
161
|
Zhang M, Townsel CD, Akers LB, Kiros L, Treadwell MC, Maturen KE. Biomechanical Cervical Assessment Using 2-Dimentional Transvaginal Shear Wave Elastography in Nonpregnant and Pregnant Women: A Prospective Pilot Study. Ultrasound Q 2021; 37:183-190. [PMID: 34057917 DOI: 10.1097/ruq.0000000000000561] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
ABSTRACT This study evaluated the technical feasibility of 2-dimensional transvaginal shear wave elastography to quantify cervical stiffness in nonpregnant and pregnant women and established normal values in each group. With institutional review board approval, we performed a prospective study with an age-matched historical control design. Sixteen premenopausal nonpregnant women without cervical pathology and 17 low-risk pregnant women (gestational age 17-33 weeks) were enrolled. Cervical shear wave speeds were measured on a SuperSonic Aixplorer machine. The mean shear wave speeds of anterior cervix were 4.96 ± 1.96 m/s in nonpregnant women and 1.92 ± 0.31 m/s in pregnant women. No significant stiffness difference was found between the anterior and posterior cervix (P = 0.15). The upper cervix was stiffer than the lower cervix in the pregnant women (P = 0.00012). Transvaginal shear wave elastography reveals that cervix at a midterm gestation is significantly softer than nonpregnant cervix (P < 0.0001) and suggests a spatial stiffness gradient along the length of the cervix, consistent with histopathology and limited elastography literature. Our results indicate the potential of transvaginal shear wave elastography to provide objective and quantitative estimates of cervical stiffness, especially during pregnancy.
Collapse
Affiliation(s)
| | | | | | - Leah Kiros
- Psychology, Michigan Medicine, University of Michigan, Ann Arbor, MI
| | | | | |
Collapse
|
162
|
Gu JH, Zhu L, Jiang TA. Quantitative Ultrasound Elastography Methods in Focal Liver Lesions Including Hepatocellular Carcinoma: From Diagnosis to Prognosis. Ultrasound Q 2021; 37:90-96. [PMID: 34057911 DOI: 10.1097/ruq.0000000000000491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
ABSTRACT The ability of ultrasound elastography to diagnose focal liver lesions and determine their prognoses including hepatocellular carcinoma (HCC) is unclear. At present, radiofrequency ablation and liver resection are the most common treatments for HCC. However, the survival rate remains disappointing because of recurrences and postoperative liver failure, necessitating the development of noninvasive approaches. There is currently no systematic definition of an elastic technique for measuring liver stiffness to predict the recurrence of HCC after radiofrequency ablation and postoperative liver failure. In this review, recent advances in ultrasound elastography for the diagnosis and prognosis of focal liver lesions are discussed including HCC.
Collapse
Affiliation(s)
- Jiong-Hui Gu
- Department of Ultrasonography, First Affiliated Hospital of Zhejiang University, Hangzhou, China
| | | | | |
Collapse
|
163
|
Stadlbauer V, Negrean I, Posch A, Streit A, Feldbacher N, Stauber RE, Horvath A. Fibroscan® probe selection for lean adults. JGH OPEN 2021; 5:750-753. [PMID: 34263068 PMCID: PMC8264238 DOI: 10.1002/jgh3.12579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Revised: 05/10/2021] [Accepted: 05/18/2021] [Indexed: 11/19/2022]
Abstract
Background and Aim Fibroscan® is used to assess fibrosis and steatosis of the liver noninvasively. The company suggests to use the S+‐probe in people <18 years with a thoracic circumference (TC) between 45 and 75 cm and the M+‐probe in children with a TC >75 cm and adults with a skin–liver capsule distance <2.5 cm. For lean adults with a TC ≤75 cm, no comparative studies have been performed. Furthermore, it is unclear whether lean adults need to be fasted before assessment. Methods We compared liver stiffness (LS) using Fibroscan® S+‐ and M+‐probes and controlled attenuation parameter (CAP; only available for M+‐probe) in healthy volunteers with a TC ≤75 cm compared with those with a TC >75 cm in fasting state and after intake of a standardized light meal (300 kcal). Results We examined 50 volunteers (26 female, 24 ± 3 years). Twenty‐two participants were in the TC ≤75 cm group and 28 in TC >75 cm group. LS values with the S+‐probe were 15% higher than with the M+‐probe in both groups (median difference 0.6 kPa, P < 0.001). Both probes showed good agreement with minimal bias (Spearman correlation r = 0.754, P < 0.001; Interclass Correlation Coefficient 0.843, P < 0.001; Bland–Altman bias 0.6 ± 0.9 kPa, linear regression r2 = 0.557, P < 0.001). Intake of a light meal had no relevant influence on LS (S+‐ and M+‐probes) or CAP measurements (M+‐probe) in both groups. Conclusion Lean adults with a TC below 75 cm can be assessed with either the S+‐probe or the M+‐probe and may take a light meal before assessment.
Collapse
Affiliation(s)
- Vanessa Stadlbauer
- Division of Gastroenterology and Hepatology, Department of Internal Medicine Medical University of Graz Graz Austria
| | - Iohanes Negrean
- Division of Gastroenterology and Hepatology, Department of Internal Medicine Medical University of Graz Graz Austria
| | - Andreas Posch
- Division of Gastroenterology and Hepatology, Department of Internal Medicine Medical University of Graz Graz Austria
| | - Andrea Streit
- Division of Gastroenterology and Hepatology, Department of Internal Medicine Medical University of Graz Graz Austria
| | - Nicole Feldbacher
- Division of Gastroenterology and Hepatology, Department of Internal Medicine Medical University of Graz Graz Austria.,Area 3 Cardiometabolic Health Center for Biomarker Research in Medicine (CBmed) Graz Austria
| | - Rudolf E Stauber
- Division of Gastroenterology and Hepatology, Department of Internal Medicine Medical University of Graz Graz Austria
| | - Angela Horvath
- Division of Gastroenterology and Hepatology, Department of Internal Medicine Medical University of Graz Graz Austria.,Area 3 Cardiometabolic Health Center for Biomarker Research in Medicine (CBmed) Graz Austria
| |
Collapse
|
164
|
Akbas M, Koyuncu FM, Artunç-Ülkümen B, Akbas G. The relation between second-trimester placental elasticity and poor obstetric outcomes in low-risk pregnancies. J Perinat Med 2021; 49:468-473. [PMID: 33554573 DOI: 10.1515/jpm-2020-0464] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Accepted: 11/17/2020] [Indexed: 12/31/2022]
Abstract
OBJECTIVES Increased placental stiffness is associated with various pathological conditions. Our objective was to evaluate the relation between the second-trimester placental elasticity value in low-risk pregnant women and poor obstetric outcomes. METHODS A total of 143 pregnant women were enrolled. Placental elasticity values were measured using the transabdominal point shear wave elastography method. 10 random measurements were obtained from different areas of the placenta. The mean was accepted as the mean placental elasticity value. Logistic regression analyses were performed to identify independent variables associated with obstetric outcomes. RESULTS Second-trimester placental elasticity value was significantly and positively associated with the poor obstetric outcomes (p=0.038). We could predict a poor outcome with 69.2% sensitivity and 60.7% specificity if we defined the placental elasticity cut-off as 3.19 kPa. Furthermore, in the multiple regression model, the placental elasticity value added significantly to the prediction of birth weight (p=0.043). CONCLUSIONS Our results showed that the pregnancies with a stiffer placenta in the second trimester were associated with an increased likelihood of exhibiting poor obstetric outcomes. Also, placental elasticity was independently associated with birth weight.
Collapse
Affiliation(s)
- Murat Akbas
- Department of Obstetrics and Gynecology, Perinatology Division, Manisa Celal Bayar University, Manisa, Turkey
| | - Faik Mumtaz Koyuncu
- Department of Obstetrics and Gynecology, Perinatology Division, Manisa Celal Bayar University, Manisa, Turkey
| | - Burcu Artunç-Ülkümen
- Department of Obstetrics and Gynecology, Perinatology Division, Manisa Celal Bayar University, Manisa, Turkey
| | | |
Collapse
|
165
|
Effects of Loading and Boundary Conditions on the Performance of Ultrasound Compressional Viscoelastography: A Computational Simulation Study to Guide Experimental Design. MATERIALS 2021; 14:ma14102590. [PMID: 34065764 PMCID: PMC8156541 DOI: 10.3390/ma14102590] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 05/10/2021] [Accepted: 05/12/2021] [Indexed: 01/01/2023]
Abstract
Most biomaterials and tissues are viscoelastic; thus, evaluating viscoelastic properties is important for numerous biomedical applications. Compressional viscoelastography is an ultrasound imaging technique used for measuring the viscoelastic properties of biomaterials and tissues. It analyzes the creep behavior of a material under an external mechanical compression. The aim of this study is to use finite element analysis to investigate how loading conditions (the distribution of the applied compressional pressure on the surface of the sample) and boundary conditions (the fixation method used to stabilize the sample) can affect the measurement accuracy of compressional viscoelastography. The results show that loading and boundary conditions in computational simulations of compressional viscoelastography can severely affect the measurement accuracy of the viscoelastic properties of materials. The measurement can only be accurate if the compressional pressure is exerted on the entire top surface of the sample, as well as if the bottom of the sample is fixed only along the vertical direction. These findings imply that, in an experimental validation study, the phantom design should take into account that the surface area of the pressure plate must be equal to or larger than that of the top surface of the sample, and the sample should be placed directly on the testing platform without any fixation (such as a sample container). The findings indicate that when applying compressional viscoelastography to real tissues in vivo, consideration should be given to the representative loading and boundary conditions. The findings of the present simulation study will provide a reference for experimental phantom designs regarding loading and boundary conditions, as well as guidance towards validating the experimental results of compressional viscoelastography.
Collapse
|
166
|
Makita A, Nagao T, Miyoshi KI, Koizumi Y, Kurata M, Kondo F, Shichijo S, Hirooka M, Yamaguchi O. The association between renal elasticity evaluated by Real-time tissue elastography and renal fibrosis. Clin Exp Nephrol 2021; 25:981-987. [PMID: 33963937 DOI: 10.1007/s10157-021-02063-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 04/12/2021] [Indexed: 12/17/2022]
Abstract
BACKGROUND The progression of chronic kidney disease (CKD) depends on the extent of fibrosis in the kidneys; however, a renal biopsy is necessary to evaluate the severity of renal fibrosis. Real-time tissue elastography (RTE), which measures heartbeat-induced tissue displacement, can assess the elasticity of organs. Here, we aimed to investigate the correlation between renal elasticity and the extent of fibrosis in renal biopsy samples. METHODS We investigated 29 consecutive patients who underwent a renal biopsy at Ehime University Hospital from February 2018 to August 2019. Renal fibrosis was categorized into three grades, mild (< 25%), moderate (25-50%), and severe (> 50%), based on the total affected area within the biopsy sample. The association between renal elasticity assessed by RTE and the grade of renal fibrosis was evaluated, and a receiver operating characteristic curve was used to distinguish the severity of renal fibrosis. RESULTS The mean age and estimated glomerular filtration rate (eGFR) were 58.8 years and 55.2 mL/min/1.73 m2, respectively. The median urine protein-to-creatinine ratio was 1.24 g/gCr. The mean renal elasticity of mild, moderate, and severe renal fibrosis was 3.40, 3.98, and 4.77, respectively. Renal elasticity of native kidneys was significantly positively correlated with the grade of renal fibrosis (ρ = 0.529, P = 0.003). At the cutoff point of 3.81, the area under the curve, sensitivity, and specificity were 0.778, 68.4%, and 81.8%, respectively. CONCLUSION Real-time tissue elastography is a promising, non-invasive method for assessing renal fibrosis in patients with CKD.
Collapse
Affiliation(s)
- Ayu Makita
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Ehime, Japan.
| | - Tomoaki Nagao
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Ken-Ichi Miyoshi
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Yohei Koizumi
- Departments of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Mie Kurata
- Department of Pathology, Ehime University Graduate School of Medicine and Proteo-Science Center, Toon, Ehime, Japan
| | - Fumikazu Kondo
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Satoru Shichijo
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Masashi Hirooka
- Departments of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Osamu Yamaguchi
- Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| |
Collapse
|
167
|
Miyoshi T, Hamaguchi M, Kitagawa N, Hashimoto Y, Fukui M. Correlation between Liver Stiffness by Two-Dimensional Shear Wave Elastography and Waist Circumference in Japanese Local Citizens with Abdominal Obesity. J Clin Med 2021; 10:jcm10091971. [PMID: 34064337 PMCID: PMC8125660 DOI: 10.3390/jcm10091971] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 04/23/2021] [Accepted: 04/30/2021] [Indexed: 12/13/2022] Open
Abstract
Background: Various factors other than fibrosis could affect liver stiffness (LS), measured by two-dimensional shear wave elastography (2D-SWE). We aimed to clarify the factors affecting LS in local citizens. Methods: We performed a cross-sectional study among local citizens of a health checkup program. Abdominal obesity was defined as waist circumference ≥85 cm for men and ≥90 cm for women. We evaluated the correlation between LS by 2D-SWE (Aplio 500) and waist circumference with linear regression analyses. We selected the following items as variables in the multivariate analysis: waist circumference, sex, hypertension, diabetes, diagnostic components of metabolic syndrome, γ−glutamyl transpeptidase, total bilirubin, NAFLD fibrosis score, and an indicator of a fatty liver, evaluated ultrasonographically. Results: Overall, 345 individuals were included; 318 (181 men and 137 women; age, 63.4 years; waist circumference, 84.0 cm; LS, 5.79 kPa) were analyzed, 128 of whom had abdominal obesity and significantly higher LS than non-abdominally obese individuals. In the multivariate analysis, waist circumference was positively, independently, and significantly correlated with LS only in abdominally obese individuals. Conclusions: Liver stiffness by 2D-SWE could increase with increases in waist circumference in local citizens with abdominal obesity. Physicians should pay attention when assessing the LS of abdominally obese individuals.
Collapse
Affiliation(s)
- Tomoki Miyoshi
- Department of Endocrinology and Metabolism, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (T.M.); (Y.H.); (M.F.)
| | - Masahide Hamaguchi
- Department of Endocrinology and Metabolism, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (T.M.); (Y.H.); (M.F.)
- Correspondence: ; Tel.: +81-75-251-5506
| | - Noriyuki Kitagawa
- Department of Diabetology, Kameoka Municipal Hospital, Kameoka 621-8585, Japan;
| | - Yoshitaka Hashimoto
- Department of Endocrinology and Metabolism, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (T.M.); (Y.H.); (M.F.)
| | - Michiaki Fukui
- Department of Endocrinology and Metabolism, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan; (T.M.); (Y.H.); (M.F.)
| |
Collapse
|
168
|
Pi Z, Wang M, Lin H, Guo Y, Chen S, Diao X, Xia H, Liu G, Zeng J, Zhang X, Chen X. Viscoelasticity measured by shear wave elastography in a rat model of nonalcoholic fatty liver disease: comparison with dynamic mechanical analysis. Biomed Eng Online 2021; 20:45. [PMID: 33941179 PMCID: PMC8091696 DOI: 10.1186/s12938-021-00879-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Accepted: 04/20/2021] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Nonalcoholic fatty liver disease (NAFLD) is rapidly becoming one of the most common liver diseases. Ultrasound elastography has been used for the diagnosis of NAFLD. However, clinical research on steatosis by elastography technology has mainly focused on steatosis with fibrosis or non-alcoholic steatohepatitis (NASH), while steatosis without fibrosis has been poorly studied. Moreover, the relationship between liver viscoelasticity and steatosis grade is not clear. In this study, we evaluated the degree of liver steatosis in a simple steatosis rat model using shear wave elastography (SWE). RESULTS The viscoelasticity values of 69 rats with hepatic steatosis were measured quantitatively by SWE in vivo and validated by a dynamic mechanical analysis (DMA) test. Pathological sections were used to determine the steatosis grade for each rat. The results showed that the elasticity values µ obtained by the two methods followed the same trend, and µ is significantly correlated with liver steatosis. The Pearson's correlation coefficients indicate that [Formula: see text] obtained by SWE is positively linear correlated with DMA (r = 0.628, p = 7.85 × 10-9). However, the viscosity values [Formula: see text] obtained by SWE were relatively independent of those obtained by DMA with a correlation coefficient of - 0.01. The combined Voigt elasticity measurements have high validity in the prediction of steatosis (S0 vs. S1-S4), with an AUROC of 0.755 (95% CI 0.6175-0.8925, p < 0.01) and the optimal cutoff value was 2.08 kPa with a sensitivity of 78% and specificity of 63%. CONCLUSION SWE might have the feasibility to be introduced as an auxiliary technique for NAFLD patients in clinical settings. However, the viscosity results measured by SWE and DMA are significantly different, because the two methods work in different frequency bands.
Collapse
Affiliation(s)
- Zhaoke Pi
- School of Biomedical Engineering, Health Science Center, Shenzhen University, National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, 518000, China
| | - Mengke Wang
- School of Biomedical Engineering, Health Science Center, Shenzhen University, National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, 518000, China
| | - Haoming Lin
- School of Biomedical Engineering, Health Science Center, Shenzhen University, National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, 518000, China
| | - Yanrong Guo
- School of Biomedical Engineering, Health Science Center, Shenzhen University, National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, 518000, China
| | - Siping Chen
- School of Biomedical Engineering, Health Science Center, Shenzhen University, National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, 518000, China
| | - Xianfen Diao
- School of Biomedical Engineering, Health Science Center, Shenzhen University, National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, 518000, China
| | - Hui Xia
- Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, 100000, China
| | - Guoqiang Liu
- Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, 100000, China
| | - Jie Zeng
- Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510000, China
| | - Xinyu Zhang
- School of Biomedical Engineering, Health Science Center, Shenzhen University, National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, 518000, China.
| | - Xin Chen
- School of Biomedical Engineering, Health Science Center, Shenzhen University, National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, 518000, China.
| |
Collapse
|
169
|
Akyuz M, Gurcan Kaya N, Esendagli G, Dalgic B, Ozhan Oktar S. The evaluation of the use of 2D shear-wave ultrasound elastography in differentiation of clinically insignificant and significant liver fibrosis in pediatric age group. Abdom Radiol (NY) 2021; 46:1941-1946. [PMID: 33231728 DOI: 10.1007/s00261-020-02844-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 10/20/2020] [Accepted: 10/24/2020] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To determine the accuracy of 2D shear-wave elastography (2D-SWE) in pediatric age group patients in differentiating clinically insignificant and significant liver fibrosis using METAVIR fibrosis scoring system as the gold standard. INTRODUCTION Liver biopsy has long been the gold standard in liver fibrosis diagnosis. However, due to probable complications and sampling variabilities, the need for more accurate and non-invasive techniques has increased. 2D-SWE is a non-invasive technique used in the evaluation of liver stiffness and utilized more and more in routine clinical practice with recent advances and researches. MATERIALS AND METHODS In this retrospective single-center study, we included 46 pediatric age group patients who had a liver parenchymal biopsy and 2D-SWE evaluation regardless of etiology. For 2D-SWE, the LOGIQ E9 system (GE Medical Systems, Wisconsin, USA) and, for histopathological evaluation, METAVIR fibrosis scoring system were utilized. Patients were further subgrouped as clinically insignificant (METAVIR Score F0-1) and significant (METAVIR Score F2-4). The Kolmogorov-Smirnov and Mann-Whitney U tests were employed for statistical analysis. The diagnostic accuracy of 2D-SWE was assessed, and cutoff values were set by ROC curve analysis. RESULTS kPa values were statistically different between clinically significant and insignificant fibrosis patient groups (p < 0.001). kPa value of 8.92 was designated as the best cutoff value according to the Youden Index. CONCLUSION 2D-SWE is one of the non-invasive techniques in the evaluation of liver fibrosis. Our findings suggest that 2D-SWE accurately differentiate clinically insignificant and significant liver fibrosis.
Collapse
Affiliation(s)
- Melih Akyuz
- Department of Diagnostic Radiology, Gazi University Hospital, Ankara, Turkey.
| | - Neslihan Gurcan Kaya
- Department of Pediatric Gastroenterology, Gazi University Hospital, Ankara, Turkey
| | - Guldal Esendagli
- Department of Pathology, Gazi University Hospital, Ankara, Turkey
| | - Buket Dalgic
- Department of Pediatric Gastroenterology, Gazi University Hospital, Ankara, Turkey
| | - Suna Ozhan Oktar
- Department of Diagnostic Radiology, Gazi University Hospital, Ankara, Turkey
| |
Collapse
|
170
|
Ferraioli G, Barr RG, Dillman JR. Elastography for Pediatric Chronic Liver Disease: A Review and Expert Opinion. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:909-928. [PMID: 32881048 DOI: 10.1002/jum.15482] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 07/28/2020] [Accepted: 08/02/2020] [Indexed: 06/11/2023]
Abstract
In adults with chronic liver diseases, ultrasound and magnetic resonance shear wave elastography (SWE) can replace liver biopsy in several clinical scenarios. Several guidelines on the use of ultrasound SWE for the adult population have been published. However, the number of publications in the pediatric population is limited, and available guidelines on SWE do not specifically address pediatric chronic liver diseases. In this article, we review the literature on the use of SWE for pediatric chronic liver diseases and provide expert opinion on how to use SWE, both ultrasound and magnetic resonance techniques, in the pediatric population.
Collapse
Affiliation(s)
- Giovanna Ferraioli
- Ultrasound Unit, Department of Clinical Sciences and Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | | | - Jonathan R Dillman
- Department of Radiology, Cincinnati Children's Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, Ohio
| |
Collapse
|
171
|
Li J, Ling W, Chen S, Yang L, Ma L, Lu Q, Luo Y. Can Risk Stratification Based on Ultrasound Elastography of Background Liver Assist CEUS LI-RADS in the Diagnosis of HCC? Front Oncol 2021; 11:662680. [PMID: 33996586 PMCID: PMC8120148 DOI: 10.3389/fonc.2021.662680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 04/16/2021] [Indexed: 02/05/2023] Open
Abstract
Objective To explore whether risk stratification based on ultrasound elastography of liver background assists contrast-enhanced ultrasound liver imaging reporting and data system (CEUS LI-RADS) in diagnosing HCC. Materials and Methods In total, 304 patients with focal liver lesions (FLLs) confirmed by pathology underwent CEUS and ultrasound elastography were included in this retrospective study. Patients with chronic hepatitis B (CHB, n=193) and non-CHB (n=111) were stratified by four liver stiffness measurement (LSM) thresholds. A LI-RADS category was assigned to FLLs using CEUS LI-RADS v2017. The diagnostic performance was assessed with the AUC, sensitivity, specificity, PPV, and NPV. Results The mean background liver stiffness of HCC patients with CHB, HCC patients without CHB and non-HCC patients without CHB were 9.72 kPa, 8.23 kPa and 4.97 kPa, respectively. The AUC, sensitivity, specificity and PPV of CEUS LI-RADS for HCC in CHB patients with LSM ≥ 5.8 kPa, ≥ 6.8 kPa, ≥ 9.1 kPa, and ≥ 10.3 kPa were high, with corresponding values of 0.745 to 0.880, 94.2% to 95.3%, 81.3% to 85.7%, and 98.1% to 98.8%, respectively. Higher AUC and specificity for HCC was observed in non-CHB patients with LSM ≥ 9.1 kPa and ≥ 10.3 kPa compared to non-CHB patients with LSM ≥ 5.8 kPa and ≥ 6.8 kPa, with corresponding values of0.964/1.000 vs 0.590/0.580, and 100%/100% vs 60%/70%, respectively. Conclusion CEUS LI-RADS has a good diagnostic performance in CHB patients regardless of the background liver stiffness. Furthermore, CEUS LI-RADS can be applied for non-CHB patients with a LSM ≥ 9.1 kPa.
Collapse
Affiliation(s)
- Jiawu Li
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Wenwu Ling
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Shuang Chen
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Lulu Yang
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Lin Ma
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Qiang Lu
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Yan Luo
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
172
|
Popa A, Bende F, Șirli R, Popescu A, Bâldea V, Lupușoru R, Cotrău R, Fofiu R, Foncea C, Sporea I. Quantification of Liver Fibrosis, Steatosis, and Viscosity Using Multiparametric Ultrasound in Patients with Non-Alcoholic Liver Disease: A "Real-Life" Cohort Study. Diagnostics (Basel) 2021; 11:diagnostics11050783. [PMID: 33926073 PMCID: PMC8146051 DOI: 10.3390/diagnostics11050783] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 04/20/2021] [Accepted: 04/25/2021] [Indexed: 12/17/2022] Open
Abstract
Non-alcoholic fatty liver disease (NAFLD) is the most common chronic liver disease worldwide. This study aimed to evaluate the performance of four ultrasound-based techniques for the non-invasive multiparametric (MPUS) assessment of liver fibrosis (LF), steatosis (HS), and inflammation in patients with NAFLD. We included 215 consecutive adult patients with NAFLD (mean age: 54.9 ± 11.7; 54.5% were male), in whom LF, HS, and viscosity were evaluated in the same session using four new ultrasound-based techniques embedded on the Aixplorer MACH 30 system: ShearWave Elastography (2D-SWE.PLUS), Sound Speed Plane-wave UltraSound (SSp.PLUS), Attenuation Plane-wave UltraSound (Att.PLUS), and Viscosity Plane-wave UltraSound (Vi.PLUS). Transient Elastography (TE) with Controlled Attenuation Parameter (CAP) (FibroScan) were considered as control. All elastographic measurements were performed according to guidelines. Valid liver stiffness measurements (LSM) were obtained in 98.6% of patients by TE, in 95.8% of patients by 2D-SWE.PLUS/Vi.PLUS, and in 98.1% of patients by Att.PLUS/SSp.PLUS, respectively. Therefore, 204 subjects were included in the final analysis. A strong correlation between LSMs by 2D-SWE.PLUS and TE (r = 0.89) was found. The best 2D-SWE.PLUS cut-off value for the presence of significant fibrosis (F ≥ 2) was 7 kPa. Regarding steatosis, SSp.PLUS correlated better than Att.PLUS with CAP values: (r = −0.74) vs. (r = 0.45). The best SSp.PLUS cut-off value for predicting the presence of significant steatosis was 1524 m/s. The multivariate regression analysis showed that Vi.PLUS values were associated with BMI and LSM by 2D-SWE.PLUS. In conclusion, MPUS was useful for assessing fibrosis, steatosis, and inflammation in a single examination in patients with NAFLD.
Collapse
|
173
|
Fofiu R, Bende F, Popescu A, Șirli R, Miuţescu B, Sporea I. Assessing Baveno VI Criteria Using Liver Stiffness Measured with a 2D-Shear Wave Elastography Technique. Diagnostics (Basel) 2021; 11:diagnostics11050737. [PMID: 33919033 PMCID: PMC8142982 DOI: 10.3390/diagnostics11050737] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 04/12/2021] [Accepted: 04/20/2021] [Indexed: 12/18/2022] Open
Abstract
The present study evaluates the performance of Baveno VI criteria, using liver stiffness (LS) assessed with a 2D-SWE elastography technique, for predicting high-risk varices (HRV) in patients with compensated advanced chronic liver disease (cACLD). A secondary aim was to determine whether the use of spleen stiffness measurements (SSMs), as additional criteria, increases the performance of the 2D-SWE Baveno VI criteria. Data were collected from 208 subjects with cACLD, who underwent abdominal ultrasound, liver and spleen stiffness measurements, and upper digestive endoscopy. HRV were defined as grade 1 esophageal varices (EV) with red wale marks, grade 2/3 EV, and gastric varices. A total of 35.6% (74/208) of the included subjects had HRV. The optimal LS cut-off value for predicting HRV was 12 kPa (AUROC-0.80). Using both LS cut-off value < 12 kPa and a platelet cut-off value > 150 × 109 cells/L as criteria to exclude HRV, 52/208 (25%) subjects were selected, 88.5% (46/52) were without EV, 9.6% (5/52) had grade 1 EV, and 1.9% (1/52) had HRV. Thus 98% of the subjects were correctly classified as having or not having HRV and 25% of the surveillance endoscopies could have been avoided. Using SS < 13.2 kPa and a platelet cut-off value > 150 × 109 cells/L as additional criteria for the patients that were outside the initial ones, 32.7% of the surveillance endoscopies could have been avoided.
Collapse
|
174
|
Kuroda H, Fujiwara Y, Abe T, Nagasawa T, Oguri T, Noguchi S, Kamiyama N, Takikawa Y. Two-dimensional shear wave elastography and ultrasound-guided attenuation parameter for progressive non-alcoholic steatohepatitis. PLoS One 2021; 16:e0249493. [PMID: 33826669 PMCID: PMC8026049 DOI: 10.1371/journal.pone.0249493] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 03/19/2021] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND AND AIMS We investigated the usefulness of combining two-dimensional shear wave elastography and the ultrasound-guided attenuation parameter for assessing the risk of progressive non-alcoholic steatohepatitis, defined as non-alcoholic steatohepatitis with a non-alcoholic fatty liver disease activity score of ≥4 and a fibrosis stage of ≥2. METHODS This prospective study included 202 patients with non-alcoholic fatty liver disease who underwent two-dimensional shear wave elastography, ultrasound-guided attenuation parameter, vibration-controlled transient elastography, the controlled attenuation parameter, and liver biopsy on the same day. Patients were grouped according to liver stiffness measurement using two-dimensional shear wave elastography and the attenuation coefficient, assessed using the ultrasound-guided attenuation parameter: A, low liver stiffness measurement/low attenuation coefficient; B, low liver stiffness measurement/high attenuation coefficient; C, high liver stiffness measurement/low attenuation coefficient; and D, high liver stiffness measurement/high attenuation coefficient. RESULTS Two-dimensional shear wave elastography and vibration-controlled transient elastography had equivalent diagnostic performance for fibrosis. The areas under the curve of the ultrasound-guided attenuation parameter for identifying steatosis grades ≥S1, ≥S2, and S3 were 0.89, 0.91, and 0.92, respectively, which were significantly better than those of the controlled attenuation parameter (P<0.05). The percentages of progressive non-alcoholic steatohepatitis in Groups A, B, C, and D were 0.0%, 7.7%, 35.7%, and 50.0%, respectively (P<0.001). The prediction model was established as logit (p) = 0.5414 × liver stiffness measurement (kPa) + 7.791 × attenuation coefficient (dB/cm/MHz)-8.401, with area under the receiver operating characteristic curve, sensitivity, and specificity values of 0.832, 80.9%, and 74.6%, respectively; there was no significant difference from the FibroScan-aspartate aminotransferase score. CONCLUSION Combined assessment by two-dimensional shear wave elastography and the ultrasound-guided attenuation parameter is useful for risk stratification of progressive non-alcoholic steatohepatitis and may be convenient for evaluating the necessity of specialist referral and liver biopsy.
Collapse
Affiliation(s)
- Hidekatsu Kuroda
- Division of Hepatology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| | - Yudai Fujiwara
- Division of Hepatology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| | - Tamami Abe
- Division of Hepatology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| | - Tomoaki Nagasawa
- Division of Hepatology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| | - Takuma Oguri
- Ultrasound General Imaging, GE Healthcare, Hino, Tokyo, Japan
| | - Sachiyo Noguchi
- Ultrasound General Imaging, GE Healthcare, Hino, Tokyo, Japan
| | | | - Yasuhiro Takikawa
- Division of Hepatology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan
| |
Collapse
|
175
|
Roccarina D, Iogna Prat L, Buzzetti E, Guerrero Misas M, Aricó FM, Saffioti F, Rosselli M, Pinzani M, Marshall A, Thorburn D, Tsochatzis E. Establishing Reliability Criteria for Liver ElastPQ Shear Wave Elastography (ElastPQ-SWE): Comparison Between 10, 5 and 3 Measurements. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2021; 42:204-213. [PMID: 31594008 DOI: 10.1055/a-1010-6052] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
PURPOSE ElastPQ is a new elastography technique for non-invasive liver fibrosis staging. However, it does not have validated reliability criteria. We tested the reliability of a different number of measurements in patients with chronic liver disease and explored whether the application of quality criteria improves the diagnostic performance. MATERIALS AND METHODS All patients underwent liver stiffness assessment (LSM) with ElastPQ and Fibroscan (F-TE). The mean, median, standard deviation (SD) and interquartile range (IQR) of 10, 5 and 3 measurements were retrospectively collected for each patient and compared to each other. Liver histology was available in a subset of patients. RESULTS Overall, 400 patients met the inclusion criteria. Non-alcoholic fatty liver disease (NAFLD) was the most represented etiology (75 %), followed by primary sclerosing cholangitis (PSC), primary biliary cholangitis (PBC) and autoimmune hepatitis (AIH). The correlation of medians was significantly better between 10 and 5 measurements than between 10 and 3. The difference of medians was significant only in the comparison between 10 and 3 measurements. The correlation between ElastPQ and F-TE was equally good for 10 and 5 measurements and significantly improved after an IQR/median ≤ 30 % was applied. The diagnostic performance of ElastPQ was better with the median value of 10 and 5 measurements and improved if LSM values were obtained with IQR/M ≤ 30 %. CONCLUSION The median value of 5 valid LSMs suffices for the reliable estimation of liver stiffness using ElastPQ. The quality criterion of IQR/M ≤ 30 % should also be followed when using this technique.
Collapse
Affiliation(s)
- Davide Roccarina
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| | - Laura Iogna Prat
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| | - Elena Buzzetti
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| | - Marta Guerrero Misas
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| | | | - Francesca Saffioti
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
- Department of Clinical and Experimental Medicine, University-Hospital and School of Medicine of Messina, Italy
| | - Matteo Rosselli
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| | - Massimo Pinzani
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| | - Aileen Marshall
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| | - Douglas Thorburn
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| | - Emmanuel Tsochatzis
- UCL Institute for Liver and Digestive Health and Sheila Sherlock Liver Unit, Royal Free Hospital and UCL, London, United Kingdom of Great Britain and Northern Ireland
| |
Collapse
|
176
|
Garcés Iñigo E, Llorens Salvador R, Escrig R, Hervás D, Vento M, Martí-Bonmatí L. Quantitative Evaluation of Neonatal Brain Elasticity Using Shear Wave Elastography. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:795-804. [PMID: 32876366 DOI: 10.1002/jum.15464] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 07/09/2020] [Accepted: 07/12/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES To demonstrate the feasibility of 2-dimensional brain ultrasound shear wave elastography (SWE) and to define the average elasticity values of the gray and white matter in term neonates. METHODS This work was a prospective observational single-center study including 55 healthy term neonates consecutively recruited in the maternity ward between the second and third postnatal days. All were successfully evaluated with a cerebral SWE examination performed with a multifrequency 4-9-MHz transducer. Bilateral sagittal planes of the thalamus and corona radiata were used to measure stiffness using a quantitative SWE method. Several elastograms with 5 to 15 nonoverlapping areas were obtained from the 2 different anatomic locations. The 5 most central measurements were averaged as representative values. RESULTS The 55 neonates ranged from 37 to 40 weeks' gestation. The estimated mean velocity values of the thalamus (1.17 m/s; 95% confidence interval, 1.13, 1.22 m/s) and corona radiata (1.60 m/s; 95% confidence interval, 1.57, 1.64 m/s) were statistically different (P < .001). There was no significant influence of laterality, gestational age, cephalic perimeter, sex, length, or type of delivery on the stiffness measurements. CONCLUSIONS Brain ultrasound SWE is feasible and allows measurements of neonatal brain elasticity. The elasticity of the thalamus and corona radiata at the frontal white matter in healthy term neonates is different. The knowledge of normal SWE ranges in term neonates allows comparative studies under pathologic conditions.
Collapse
Affiliation(s)
| | | | - Raquel Escrig
- Department of Pediatrics, Neonatal Research Unit, Hospital Universitario y Politécnico La Fe, Valencia, Spain
| | - David Hervás
- Data Science, Biostatistics, and Bioinformatics Platform, Instituto de Investigación Sanitaria La Fe, Valencia, Spain
| | - Máximo Vento
- Department of Pediatrics, Neonatal Research Unit, Hospital Universitario y Politécnico La Fe, Valencia, Spain
| | - Luis Martí-Bonmatí
- Department of Radiology, Hospital Universitario y Politécnico La Fe, Valencia, Spain
- Research Group on Biomedical Imaging, Instituto de Investigación Sanitaria La Fe, Valencia, Spain
| |
Collapse
|
177
|
Ozturk A, Zubajlo RE, Dhyani M, Grajo JR, Mercaldo N, Anthony BW, Samir AE. Variation of Shear Wave Elastography With Preload in the Thyroid: Quantitative Validation. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:779-786. [PMID: 32951229 DOI: 10.1002/jum.15456] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Revised: 07/23/2020] [Accepted: 07/24/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES Thyroid shear wave elastography (SWE) has been shown to have advantages compared to biopsy or other imaging modalities in the evaluation of thyroid nodules. However, studies show variability in its assessment. The objective of this study was to evaluate whether stiffness measurements of the normal thyroid, as estimated by SWE, varied due to preload force or the pressure applied between the transducer and the patient. METHODS In this study, a measurement system was attached to the ultrasound transducer to measure the applied load. Shear wave elastographic measurements were obtained from the left lobe of the thyroid at applied transducer forces between 2 and 10 N. A linear mixed-effects model was constructed to quantify the association between the preload force and stiffness while accounting for correlations between repeated measurements within each participant. The preload force effect on elasticity was modeled by both linear and quadratic terms to account for a possible nonlinear association between these variables. RESULTS Nineteen healthy volunteers without known thyroid disease participated in the study. The participants had a mean age ± SD of 36 ± 8 years; 74% were female; 74% had a normal body mass index; and 95% were white non-Hispanic/Latino. The estimated elastographic value at a 2-N preload force was 16.7 kPa (95% confidence interval, 14.1-19.3 kPa), whereas the value at 10 N was 29.9 kPa (95% confidence interval, 24.9-34.9 kPa). CONCLUSIONS The preload force was significantly and nonlinearly associated with SWE estimates of thyroid stiffness. Quantitative standardization of preload forces in the assessment of thyroid nodules using elastography is an integral factor for improving the accuracy of thyroid nodule evaluation.
Collapse
Affiliation(s)
- Arinc Ozturk
- Center for Ultrasound Research & Translation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Rebecca E Zubajlo
- Department of Mechanical Engineering, Massachusetts Institutes of Technology, Cambridge, Massachusetts, USA
| | - Manish Dhyani
- Department of Radiology, Lahey Hospital and Medical Center, Burlington, Massachusetts, USA
| | - Joseph R Grajo
- Division of Abdominal Imaging, Department of Radiology, University of Florida College of Medicine, Gainesville, Florida, USA
| | - Nathaniel Mercaldo
- Department of Neurology, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Brian W Anthony
- Department of Mechanical Engineering, Massachusetts Institutes of Technology, Cambridge, Massachusetts, USA
| | - Anthony E Samir
- Center for Ultrasound Research & Translation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA
| |
Collapse
|
178
|
Wong A, Yusuf GT, Malbrain MLNG. Future developments in the imaging of the gastrointestinal tract: the role of ultrasound. Curr Opin Crit Care 2021; 27:147-156. [PMID: 33560015 DOI: 10.1097/mcc.0000000000000815] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
PURPOSE OF REVIEW The purpose of this review is to summarize the utilization and most recent developments with regard to the use of ultrasound when imaging the abdomen and gastrointestinal tract. RECENT FINDINGS Although the use of ultrasound to assess the anatomy of the various abdominal organs is well established within radiology and critical care, its use as part of functional and physiological assessment is still evolving. Recent developments have extended the use of ultrasound beyond standard B-mode/2D imaging techniques to incorporate more functional and haemodynamic assessment. These include the use of contrast-enhanced ultrasound (CEUS), elastography, and colour Doppler techniques. SUMMARY Whilst Doppler techniques are reasonably well established within critical care ultrasound (CCUS), especially in echocardiography, CEUS and elastography are less well known. CEUS utilizes a purely intravascular contrast agent whilst elastography measures the degree of deformation or stiffness in various organs. Whilst their use individually may be limited; they may play a role in a multiparametric assessment. Mirroring the overall trends in critical care ultrasound development, abdominal ultrasound assessment is best integrated in a holistic approach and adapted to the individual patient.
Collapse
Affiliation(s)
| | | | - Manu L N G Malbrain
- Faculty of Engineering, Department of Electronics and Informatics, VUB, Brussels, Belgium
| |
Collapse
|
179
|
Lee DH, Cho EJ, Bae JS, Lee JY, Yu SJ, Kim H, Lee KB, Han JK, Choi BI. Accuracy of Two-Dimensional Shear Wave Elastography and Attenuation Imaging for Evaluation of Patients With Nonalcoholic Steatohepatitis. Clin Gastroenterol Hepatol 2021; 19:797-805.e7. [PMID: 32450363 DOI: 10.1016/j.cgh.2020.05.034] [Citation(s) in RCA: 88] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 05/06/2020] [Accepted: 05/16/2020] [Indexed: 12/11/2022]
Abstract
BACKGROUND & AIMS We evaluated the accuracy of a multiparametric approach using attenuation imaging and 2-dimensional shear wave elastography (2D-SWE) for the detection of steatosis and fibrosis in patients with nonalcoholic fatty liver disease (NAFLD). METHODS We studied 102 patients with increased levels of liver enzymes or suspicion of NAFLD, examined by attenuation imaging and 2D-SWE, immediately before biopsy collection and analysis (reference standard), from January 2018 to July 2019. We collected data on the attenuation coefficient (dB/cm/MHz) from attenuation imaging, liver stiffness measurements, and shear wave dispersion slope (SWDS, [m/s]/kHz) from 2D-SWE. Multivariate linear regression analysis was performed to identify factors associated with each parameter. Diagnostic performance was determined from area under the receiver operating curve (AUROC) values. RESULTS The attenuation coefficient was associated with steatosis grade (P < .01) and identified patients with steatosis grades S1 or higher, S2 or higher, and S3 or higher, with AUROC values of 0.93, 0.88, and 0.83, respectively. Liver stiffness associated with fibrosis stage (P < .01) and lobular inflammatory activity was the only factor associated with SWDS (P < .01). SWDS detected inflammation grades I1 or higher, I2 or higher, and I3 or higher with AUROC values of 0.89, 0.85, and 0.78, respectively. We developed a risk scoring system to detect steatohepatitis based on the attenuation coefficient (score of 1 for 0.64 < attenuation coefficient ≤ 0.70; score of 2 for 0.70 < attenuation coefficient ≤ 0.73; and score of 3 for attenuation coefficient >0.73) and SWDS (score of 2 for 10.5 [m/s]/kHz < SWDS ≤ 11.7 [m/s]/kHz; and score of 3 for SWDS >11.7 [m/s]/kHz), using an unweighted sum of each score. Based on histopathology analysis, 55 patients had steatohepatitis. Risk scores correlated with NAFLD activity score (rho = 0.73; P < .01). Our scoring system identified patients with steatohepatitis with an AUROC of 0.93-this value was significantly higher than that of other parameters (P < .05), except SWDS (AUROC, 0.89; P = .18). CONCLUSIONS In the evaluation of patients with suspected NAFLD, the attenuation coefficient can identify patients with steatosis and liver stiffness can detect fibrosis accurately. SWDS was associated significantly with lobular inflammation. We developed a risk scoring system based on the attenuation coefficient and SWDS that might be used to detect steatohepatitis.
Collapse
Affiliation(s)
- Dong Ho Lee
- Department of Radiology, Seoul National University Hospital; Institute of Radiation Medicine, Seoul National University Medical Research Center
| | - Eun Ju Cho
- Department of Internal Medicine and Liver Research Institute
| | - Jae Seok Bae
- Department of Radiology, Seoul National University Hospital
| | - Jae Young Lee
- Department of Radiology, Seoul National University Hospital; Institute of Radiation Medicine, Seoul National University Medical Research Center; Department of Radiology.
| | - Su Jong Yu
- Department of Internal Medicine and Liver Research Institute
| | - Haeryoung Kim
- Department of Pathology, Seoul National University College of Medicine
| | - Kyung Bun Lee
- Department of Pathology, Seoul National University College of Medicine
| | - Joon Koo Han
- Department of Radiology, Seoul National University Hospital; Institute of Radiation Medicine, Seoul National University Medical Research Center; Department of Radiology
| | - Byung Ihn Choi
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea
| |
Collapse
|
180
|
Comparison of preoperative two-dimensional shear wave elastography, indocyanine green clearance test and biomarkers for post hepatectomy liver failure prediction in patients with hepatocellular carcinoma. BMC Gastroenterol 2021; 21:142. [PMID: 33789567 PMCID: PMC8010946 DOI: 10.1186/s12876-021-01727-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 03/17/2021] [Indexed: 02/08/2023] Open
Abstract
Background The preoperative prediction of post hepatectomy liver failure (PHLF) is essential, but there is no gold standard for the prediction at present, and the efficacy of different methods for the prediction has not been compared systematically. In this study, we aimed to compare the efficacy of preoperative two-dimensional shear wave elastography (2D-SWE), indocyanine green (ICG) clearance test and biomarkers for PHLF prediction in patients with hepatocellular carcinoma (HCC). Methods We retrospectively studied 215 patients with HCC, who had undergone major liver resection in our hospital. Preoperative data of each patient, including liver stiffness value (LSV) of underlying hepatic parenchyma measured by 2D-SWE, ICG retention rate at 15 min (ICG-R15) measured by ICG clearance test, albumin-bilirubin (ALBI) scores, aspartate aminotransferase–platelet ratio index (APRI), and Fibrosis-4 (FIB-4) were collected for analysis. Post hepatectomy outcomes of study patients were also recorded for assessment of PHLF. The study patients were divided into development cohort (133 patients without PHLF, and 17 patients with PHLF) and validation cohort (59 patients without PHLF, and 6 patients with PHLF) randomly. Results In the development cohort, LSV, ICG-R15 and ALBI scores were significantly different between patients with and without PHLF, while no significant difference of APRI and FIB-4 scores was found. LSV had higher AUC (the area under the receiver operating characteristic curve) (AUC = 0.795) for PHLF prediction than ICG-R15 (AUC = 0.619) and ALBI scores (AUC = 0.686) (p < 0.05 for all comparisons). In the validation cohort, the cutoff value of LSV obtained from the development cohort, 10.35 kPa, revealed higher specificity (76.3%) for PHLF prediction than ICG-R15 (specificity: 66.1%) and ALBI scores (specificity: 69.5%) (p < 0.0001). Conclusions Compared with ICG-R15, ALBI scores, APRI and FIB-4, LSV measured by 2D-SWE may demonstrate better efficacy for preoperative PHLF prediction in patients with HCC.
Collapse
|
181
|
Spleen Stiffness for Predicting Varices Needing Treatment: Comparison between Two Different Elastography Techniques (Point vs. 2D-SWE). Can J Gastroenterol Hepatol 2021; 2021:6622726. [PMID: 34055675 PMCID: PMC8130909 DOI: 10.1155/2021/6622726] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 03/17/2021] [Accepted: 03/19/2021] [Indexed: 02/06/2023] Open
Abstract
The study aimed to establish the benefits of using spleen stiffness values measured by two elastography techniques as noninvasive markers for predicting varices needing treatment and comparing their performances. A prospective study was performed, including 107 subjects with compensated liver cirrhosis, who underwent upper digestive endoscopy, as well as spleen stiffness measurements by means of two elastography techniques: pSWE (point shear wave elastography using Virtual Touch Quantification-Siemens Acuson S2000) and 2D-SWE (2D-shear wave elastography-LOGIQ E9, General Electric). Reliable spleen stiffness measurements were obtained in 96.2% (103/107) patients by means of 2D-SWE and in 94.4% (101/107) subjects with pSWE; therefore, 98 subjects were included in the final analysis, of which 40.8% (40/98) had varices needing treatment. The optimal spleen stiffness cut-off value by 2D-SWE for predicting varices needing treatment was 13.2 kPa (AUROC 0.84), while for pSWE, it was 2.91 m/s (AUROC 0.90). Based on AUROC comparison, no difference between the performance of the two techniques for predicting varices needing treatment was found (p=0.1606). In conclusion, spleen stiffness measured by either 2D-SWE or pSWE is a reliable surrogate marker, with good feasibility, applicability, and predictive accuracy for varices needing treatment, with no significant difference between techniques.
Collapse
|
182
|
Intra-System Reliability Assessment of 2-Dimensional Shear Wave Elastography. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11072992] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The availability of 2-Dimensional Shear Wave Elastography (2D-SWE) technology on modern medical ultrasound systems is becoming increasingly common. The technology is now being used to investigate a range of soft tissues and related pathological conditions. This work investigated the reliability of a single commercial 2D-SWE system using a tissue-mimicking elastography phantom to understand the major causes of intra-system variability. Sources of shear wave velocity (SWV) measurement variability relates to imaging depth, target stiffness, sampling technique and the operator. Higher SWV measurement variability was evident with increasing depth and stiffness of the phantom targets. The influence of the operator was minimal, and variations in sampling technique had little impact on the SWV.
Collapse
|
183
|
Ramot Y, Deshpande A, Morello V, Michieli P, Shlomov T, Nyska A. Microscope-Based Automated Quantification of Liver Fibrosis in Mice Using a Deep Learning Algorithm. Toxicol Pathol 2021; 49:1126-1133. [PMID: 33769147 DOI: 10.1177/01926233211003866] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
In preclinical studies that involve animal models for hepatic fibrosis, accurate quantification of the fibrosis is of utmost importance. The use of digital image analysis based on deep learning artificial intelligence (AI) algorithms can facilitate accurate evaluation of liver fibrosis in these models. In the present study, we compared the quantitative evaluation of collagen proportionate area in the carbon tetrachloride model of liver fibrosis in the mouse by a newly developed AI algorithm to the semiquantitative assessment of liver fibrosis performed by a board-certified toxicologic pathologist. We found an excellent correlation between the 2 methods of assessment, most evident in the higher magnification (×40) as compared to the lower magnification (×10). These findings strengthen the confidence of using digital tools in the toxicologic pathology field as an adjunct to an expert toxicologic pathologist.
Collapse
Affiliation(s)
- Yuval Ramot
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.,Department of Dermatology, 58884Hadassah Medical Center, Jerusalem, Israel
| | | | | | - Paolo Michieli
- AgomAb Therapeutics NV, Gent, Belgium.,Molecular Biotechnology Center, University of Torino, Torino, Italy
| | - Tehila Shlomov
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.,Hadassah Medical Center, Jerusalem, Israel
| | - Abraham Nyska
- Consultant in Toxicologic Pathology, 26745Tel Aviv and Tel Aviv University, Israel
| |
Collapse
|
184
|
Iino Y, Maruyama H, Mikata R, Yasui S, Koroki K, Nagashima H, Awatsu M, Shingyoji A, Kusakabe Y, Kobayashi K, Kiyono S, Nakamura M, Ohyama H, Sugiyama H, Sakai Y, Chiba T, Kato J, Tsuyuguchi T, Kato N. Percutaneous Two-Dimensional Shear Wave Elastography for Diagnosis of Pancreatic Tumor. Diagnostics (Basel) 2021; 11:diagnostics11030498. [PMID: 33799777 PMCID: PMC8001884 DOI: 10.3390/diagnostics11030498] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 03/03/2021] [Accepted: 03/05/2021] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND To investigate the efficacy of two-dimensional shear wave elastography (2D-SWE) for the diagnosis of pancreatic mass lesions. METHODS This ethics committee-approved cross-sectional study included 52 patients with histologically-proven pancreatic tumors (pancreatic ductal adenocarcinoma (PDAC), 36; tumor-forming pancreatitis (TFP), 15; neuroendocrine tumor, 1) and 33 control subjects. The 2D-SWE was performed for the tumor/non-tumor tissues, and SWE-mapping patterns and propagation quality were assessed. RESULTS Three mapping patterns were detected based on the size and distribution of the coloring areas. Pattern A (whole coloring) was detected in all non-tumor tissues and TFP, whereas pattern C (multiple small coloring spots) was detected in PDAC only. Pattern B (partial coloring with smaller spots) was detected in other lesions. The specificity and positive predictive value of pattern A for non-PDAC and those of pattern C for PDAC were 100%. The SWE value was higher in tumor lesions than in the non-tumor tissues (38.1 vs. 9.8 kPa; p < 0.001) in patients with PDAC. The SWE value in the non-tumor lesion was higher in patients with PDAC than in control (9.8 vs. 7.5 kPa; p < 0.001). CONCLUSIONS 2D-SWE may play a role as a novel diagnostic tool for PDAC to detect a specific mapping pattern with quantitative assessment.
Collapse
|
185
|
Idobe-Fujii Y, Omoso R, Fujii S, Fujiwara H, Nakamura Y, Nomi T, Sasaki Y, Sasaki H, Isomoto H, Murawaki Y. Normal values of combinational elastography in adult liver: the influence of age. J Med Ultrason (2001) 2021; 48:207-213. [PMID: 33651239 DOI: 10.1007/s10396-021-01082-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 02/12/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE We aimed to clarify the normal values obtained by simultaneous use of shear wave imaging and strain imaging (combinational elastography) in liver and reveal how aging influences them. METHODS In our checkup center, 257 examinees were diagnosed with normal liver based on questionnaires about liver disease and their drinking history, liver function test results, and ultrasound B-mode study findings. We estimated the values of combinational elastography and considered the correlation between the values and age. A multivariate analysis was performed concerning several features and the liver fibrosis (LF) index. We divided examinees into a younger group (< 65 years old) and an older group (≥ 65 years old), and assessed the effect of age on the LF index. RESULTS The mean shear wave velocity (Vs) of shear wave measurement (SWM) was 1.10 ± 0.17 m/s (range 0.84-1.93), and the mean LF index of real-time tissue elastography (RTE) was 1.371 ± 0.458 (range 0.258-3.173). There was no significant correlation between Vs and age. However, the LF index increased significantly with age. The multivariate analysis showed that age (P < 0.001) and BMI (P < 0.05) significantly affected the LF index. Indeed, the LF index in the older group was significantly higher than that in the younger group (P < 0.001). CONCLUSION In adult liver, the normal Vs of SWM was 1.10 ± 0.17 m/s, and the normal LF index of RTE was 1.371 ± 0.458. The LF index increased significantly with age in contrast to Vs; therefore, the influence of age should be considered when using combinational elastography.
Collapse
Affiliation(s)
- Yoko Idobe-Fujii
- Checkup Center, Saiseikai Sakaiminato General Hospital, 44 Yonegawa-cho, Sakaiminato, Tottori, 684-8555, Japan.
| | - Ryoko Omoso
- Clinical Laboratory, Saiseikai Sakaiminato General Hospital, Tottori, Japan
| | - Shinya Fujii
- Division of Radiology, Department of Multidisciplinary Internal Medicine, Tottori University Faculty of Medicine, Tottori, Japan
| | - Hiromitsu Fujiwara
- Clinical Laboratory, Saiseikai Sakaiminato General Hospital, Tottori, Japan
| | - Yuki Nakamura
- Department of Gastroenterology, Saiseikai Sakaiminato General Hospital, Tottori, Japan
| | - Takahiro Nomi
- Department of Gastroenterology, Saiseikai Sakaiminato General Hospital, Tottori, Japan
| | - Yuichiro Sasaki
- Department of Gastroenterology, Saiseikai Sakaiminato General Hospital, Tottori, Japan
| | - Hiroyuki Sasaki
- Checkup Center, Saiseikai Sakaiminato General Hospital, 44 Yonegawa-cho, Sakaiminato, Tottori, 684-8555, Japan
| | - Hajime Isomoto
- Division of Gastroenterology and Nephrology, Department of Multidisciplinary Internal Medicine, Tottori University Faculty of Medicine, Tottori, Japan
| | - Yoshikazu Murawaki
- Department of Gastroenterology, Saiseikai Sakaiminato General Hospital, Tottori, Japan
| |
Collapse
|
186
|
Mathon B, Clemenceau S, Carpentier A. Intraoperative Ultrasound Shear-Wave Elastography in Focal Cortical Dysplasia Surgery. J Clin Med 2021; 10:jcm10051049. [PMID: 33802551 PMCID: PMC7961510 DOI: 10.3390/jcm10051049] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Revised: 02/15/2021] [Accepted: 02/28/2021] [Indexed: 12/31/2022] Open
Abstract
Previous studies reported interest in intraoperative shear-wave elastography (SWE) guidance for brain-tumor and epilepsy surgeries. Focal cortical dysplasia (FCD) surgery is one of the most appropriate indications for using SWE guidance. The aim of this study was to evaluate the efficacy of ultrasound SWE techniques for the intraoperative detection of FCDs. We retrospectively analyzed data from 18 adult patients with drug-resistant epilepsy associated with FCD who had undergone SWE-guided surgery. Conventional B-mode images detected FCD in 2 patients (11.1%), while SWE detected FCD in 14 patients (77.8%). The stiffness ratios between MRI-positive and -negative cases were significantly different (3.6 ± 0.4 vs. 2.2 ± 0.6, respectively; p < 0.001). FCDs were significantly more frequently detected by interoperative SWE in women (OR 4.7, 95% CI (1.7–12.7); p = 0.004) and in patients in whom FCD was visible on magnetic resonance imaging (MRI; OR 2.3, 95% CI (1.3–4.3); p = 0.04). At 1 year after surgery and at last follow-up (mean = 21 months), seizure outcome was good (International League Against Epilepsy (ILAE) Class 1 or 2) in 72.2% and 55.6% of patients, respectively. Despite some limitations, our study highlighted the potential of SWE as an intraoperative tool to detect FCD. Future technical developments should allow for optimizing intraoperative surgical-cavity evaluation from the perspective of complete FCD resection. Interobserver reliability of SWE measurements should also be assessed by further studies.
Collapse
Affiliation(s)
- Bertrand Mathon
- Department of Neurosurgery, La Pitié-Salpêtrière University Hospital, Assistance Publique-Hôpitaux de Paris, 75013 Paris, France; (S.C.); (A.C.)
- Faculty of Medicine, Sorbonne University, 75005 Paris, France
- Paris Brain Institute (ICM, INSERM, UMRS 1127, CNRS, UMR 7225), 75013 Paris, France
- Correspondence: ; Tel.: +33-1-4216-3408
| | - Stéphane Clemenceau
- Department of Neurosurgery, La Pitié-Salpêtrière University Hospital, Assistance Publique-Hôpitaux de Paris, 75013 Paris, France; (S.C.); (A.C.)
| | - Alexandre Carpentier
- Department of Neurosurgery, La Pitié-Salpêtrière University Hospital, Assistance Publique-Hôpitaux de Paris, 75013 Paris, France; (S.C.); (A.C.)
- Faculty of Medicine, Sorbonne University, 75005 Paris, France
- Paris Brain Institute (ICM, INSERM, UMRS 1127, CNRS, UMR 7225), 75013 Paris, France
| |
Collapse
|
187
|
Kijanka P, Urban MW. Local Phase Velocity Based Imaging of Viscoelastic Phantoms and Tissues. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:389-405. [PMID: 31976887 PMCID: PMC7590236 DOI: 10.1109/tuffc.2020.2968147] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Assessment of soft tissue elasticity and viscosity is of interest in several clinical applications. In this study, we present the feasibility of the local phase velocity based imaging (LPVI) method to create images of phase velocity and viscoelastic parameters in viscoelastic tissue-mimicking materials and soft tissues. In viscoelastic materials, it is necessary to utilize wave-mode isolation using a narrow bandpass filter combined with a directional filter in order to robustly reconstruct phase velocity images with LPVI in viscoelastic media over a wide range of frequencies. A pair of sequential focused acoustic radiation force push beams, focused once on the left-hand side and once on the right-hand side of the probe, was used to produce broadband propagating shear waves. The local shear wave phase velocity is then recovered in the frequency domain for multiple frequencies, for both acquired data sets. Then, a 2-D shear wave velocity map is reconstructed by combining maps from two separate acquisitions. By testing the method on simulated data sets and performing in vitro phantom and in vivo liver tissue experiments, we show the ability of the proposed technique to generate shear wave phase velocity maps at various frequencies in viscoelastic materials. Moreover, a nonlinear least-squares problem is solved in order to locally estimate elasticity and viscosity parameters. The LPVI method with added directional and wavenumber filters can produce phase velocity images, which can be used to characterize the viscoelastic materials.
Collapse
|
188
|
Palmeri ML, Milkowski A, Barr R, Carson P, Couade M, Chen J, Chen S, Dhyani M, Ehman R, Garra B, Gee A, Guenette G, Hah Z, Lynch T, Macdonald M, Managuli R, Miette V, Nightingale KR, Obuchowski N, Rouze NC, Morris DC, Fielding S, Deng Y, Chan D, Choudhury K, Yang S, Samir AE, Shamdasani V, Urban M, Wear K, Xie H, Ozturk A, Qiang B, Song P, McAleavey S, Rosenzweig S, Wang M, Okamura Y, McLaughlin G, Chen Y, Napolitano D, Carlson L, Erpelding T, Hall TJ. Radiological Society of North America/Quantitative Imaging Biomarker Alliance Shear Wave Speed Bias Quantification in Elastic and Viscoelastic Phantoms. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:569-581. [PMID: 33410183 PMCID: PMC8082942 DOI: 10.1002/jum.15609] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 11/20/2020] [Accepted: 11/29/2020] [Indexed: 05/12/2023]
Abstract
OBJECTIVES To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms. METHODS Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz. RESULTS The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a - 0.27 ± 0.027-m/s (-12.2% ± 1.2%) bias when using the clinically implemented 60-Hz vibration source. CONCLUSIONS Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140-Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.
Collapse
Affiliation(s)
| | | | - Richard Barr
- The Surgical Hospital at Southwoods, Boardman, Ohio, USA
| | - Paul Carson
- University of Michigan, Ann Arbor, Michigan, USA
| | | | - Jun Chen
- Mayo Clinic, Rochester, Minnesota, USA
| | | | - Manish Dhyani
- Massachusetts General Hospital, Boston, Massachusetts, USA
| | | | - Brian Garra
- US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Albert Gee
- Zonare Medical Systems, Mountain View, California, USA
| | - Gilles Guenette
- Toshiba Medical Research Institute, Redmond, Washington, USA
| | | | | | | | | | | | | | | | - Ned C Rouze
- Duke University, Durham, North Carolina, USA
| | | | | | - Yufeng Deng
- Duke University, Durham, North Carolina, USA
| | - Derek Chan
- Duke University, Durham, North Carolina, USA
| | | | - Siyun Yang
- Duke University, Durham, North Carolina, USA
| | | | | | | | - Keith Wear
- US Food and Drug Administration, Silver Spring, Maryland, USA
| | - Hua Xie
- Philips Research, Cambridge, Massachusetts, USA
| | - Arinc Ozturk
- Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Bo Qiang
- Mayo Clinic, Rochester, Minnesota, USA
| | | | | | | | | | | | | | - Yuling Chen
- Zonare Medical Systems, Mountain View, California, USA
| | | | | | | | | |
Collapse
|
189
|
Zayed A, Rivaz H. Fast Strain Estimation and Frame Selection in Ultrasound Elastography Using Machine Learning. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:406-415. [PMID: 32406831 DOI: 10.1109/tuffc.2020.2994028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Ultrasound elastography aims to determine the mechanical properties of the tissue by monitoring tissue deformation due to internal or external forces. Tissue deformations are estimated from ultrasound radio frequency (RF) signals and are often referred to as time delay estimation (TDE). Given two RF frames I1 and I2 , we can compute a displacement image, which shows the change in the position of each sample in I1 to a new position in I2 . Two important challenges in TDE include high computational complexity and the difficulty in choosing suitable RF frames. Selecting suitable frames is of high importance because many pairs of RF frames either do not have acceptable deformation for extracting informative strain images or are decorrelated and deformation cannot be reliably estimated. Herein, we introduce a method that learns 12 displacement modes in quasi-static elastography by performing principal component analysis (PCA) on displacement fields of a large training database. In the inference stage, we use dynamic programming (DP) to compute an initial displacement estimate of around 1% of the samples and then decompose this sparse displacement into a linear combination of the 12 displacement modes. Our method assumes that the displacement of the whole image could also be described by this linear combination of principal components. We then use the GLobal Ultrasound Elastography (GLUE) method to fine-tune the result yielding the exact displacement image. Our method, which we call PCA-GLUE, is more than 10× faster than DP in calculating the initial displacement map while giving the same result. This is due to converting the problem of estimating millions of variables in DP into a much simpler problem of only 12 unknown weights of the principal components. Our second contribution in this article is determining the suitability of the frame pair I1 and I2 for strain estimation, which we achieve by using the weight vector that we calculated for PCA-GLUE as an input to a multilayer perceptron (MLP) classifier. We validate PCA-GLUE using simulation, phantom, and in vivo data. Our classifier takes only 1.5 ms during the testing phase and has an F1-measure of more than 92% when tested on 1430 instances collected from both phantom and in vivo data sets.
Collapse
|
190
|
Hirooka M, Koizumi Y, Tanaka T, Sunago K, Nakamura Y, Yukimoto A, Watanabe T, Yoshida O, Tokumoto Y, Abe M, Hiasa Y. Dilatation of lymphatic vessels increases liver stiffness on transient elastography irrespective of fibrosis. Hepatol Res 2021; 51:284-293. [PMID: 33368940 DOI: 10.1111/hepr.13610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 11/25/2020] [Accepted: 12/10/2020] [Indexed: 02/08/2023]
Abstract
AIM Liver stiffness measured using transient elastography (TE) is affected by tissue viscosity. The role of intrahepatic lymphatic fluid in liver stiffness is unclear. The present study aimed to investigate the effects of lymphatic vessel dilatation on liver stiffness. METHODS Patients with chronic liver disease (n = 116) were enrolled from June 2018 to March 2020. All specimens were acquired by laparoscopic liver biopsy. Biopsy samples were stained with D2-40 for lymphatic vessel quantification based on a five-point scale for each specimen. Independent associations of liver stiffness measured by TE, strain elasticity (liver fibrosis index), and controlled attenuation parameter with fibrosis, lymphatic vessels, alanine aminotransferase, bilirubin, and steatosis were evaluated. RESULTS Fibrosis, splenic stiffness measurement, and splenic volume were significantly correlated with the area of lymphatic vessels. Fibrosis, lymphatic vessels, and alanine aminotransferase were independent factors significantly associated with liver stiffness measurement (LSM; standardized coefficient [β] = 0.375, P < 0.001; β = 0.342, P < 0.001; and β = 0.359, P < 0.001, respectively). Fibrosis was the only independent factor significantly associated with liver fibrosis index (β = 0.360, P < 0.001), whereas the fat deposit area was the only independent factor significantly associated with controlled attenuation parameter (β = 0.455, P < 0.001). The areas under the receiver operating characteristic curves for diagnosing controlled ascites based on LSM, liver fibrosis index, splenic stiffness measurement, collagen proportionate area, and area of lymphatic vessels were 0.94, 0.66, 0.76, 0.64, and 0.79, respectively. CONCLUSIONS Lymphatic vessel dilatation can affect liver stiffness measured using TE. Liver stiffness measurement is a predictive factor for ascites.
Collapse
Affiliation(s)
- Masashi Hirooka
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Yohei Koizumi
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Takaaki Tanaka
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Kotarou Sunago
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Yoshiko Nakamura
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Atsushi Yukimoto
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Takao Watanabe
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Osamu Yoshida
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Yoshio Tokumoto
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Masanori Abe
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| | - Yoichi Hiasa
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan
| |
Collapse
|
191
|
Ju BJ, Jin M, Tian Y, Zhen X, Kong DX, Wang WL, Yan S. Model for liver hardness using two-dimensional shear wave elastography, durometer, and preoperative biomarkers. World J Gastrointest Surg 2021; 13:127-140. [PMID: 33643533 PMCID: PMC7898182 DOI: 10.4240/wjgs.v13.i2.127] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 11/27/2020] [Accepted: 12/17/2020] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Post-hepatectomy liver failure (PHLF) increases morbidity and mortality after liver resection for patients with advanced liver fibrosis and cirrhosis. Preoperative liver stiffness using two-dimensional shear wave elastography (2D-SWE) is widely used to evaluate the degree of fibrosis. However, the 2D-SWE results were not accurate. A durometer measures hardness by quantifying the ability of a material to locally resist the intrusion of hard objects into its surface. However, the durometer score can only be obtained during surgery.
AIM To measure correlations among 2D-SWE, palpation by surgeons, and durometer-measured objective liver hardness and to construct a liver hardness regression model.
METHODS We enrolled 74 hepatectomy patients with liver hardness in a derivation cohort. Tactile-based liver hardness scores (0-100) were determined through palpation of the liver tissue by surgeons. Additionally, liver hardness was measured using a durometer. Correlation coefficients for durometer-measured hardness and preoperative parameters were calculated. Multiple linear regression models were constructed to select the best predictive durometer scale. Receiver operating characteristic (ROC) curves and univariate and multivariate analyses were used to calculate the best model’s prediction of PHLF and risk factors for PHLF, respectively. A separate validation cohort (n = 162) was used to evaluate the model.
RESULTS The stiffness measured using 2D-SWE and palpation scale had good linear correlation with durometer-measured hardness (Pearson rank correlation coefficient 0.704 and 0.729, respectively, P < 0.001). The best model for the durometer scale (hardness scale model) was based on stiffness, hepatitis B virus surface antigen, and albumin level and had an R2 value of 0.580. The area under the ROC for the durometer and hardness scale for PHLF prediction were 0.807 (P = 0.002) and 0.785 (P = 0.005), respectively. The optimal cutoff value of the durometer and hardness scale was 27.38 (sensitivity = 0.900, specificity = 0.660) and 27.87 (sensitivity = 0.700, specificity = 0.787), respectively. Patients with a hardness scale score of > 27.87 were at a significantly higher risk of PHLF with hazard ratios of 7.835 (P = 0.015). The model’s PHLF predictive ability was confirmed in the validation cohort.
CONCLUSION Liver stiffness assessed by 2D-SWE and palpation correlated well with durometer hardness values. The multiple linear regression model predicted durometer hardness values and PHLF.
Collapse
Affiliation(s)
- Bing-Jie Ju
- Department of Hepatobiliary and Pancreatic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China
- Key Laboratory of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Tumor of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Research Center of Diagnosis and Treatment Technology for Hepatocellular Carcinoma of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Clinical Medicine Innovation Center of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Disease of Zhejiang University, Hangzhou 310009, Zhejiang Province, China
- Clinical Research Center of Hepatobiliary and Pancreatic Diseases of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
| | - Ming Jin
- Department of Hepatobiliary and Pancreatic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China
- Key Laboratory of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Tumor of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Research Center of Diagnosis and Treatment Technology for Hepatocellular Carcinoma of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Clinical Medicine Innovation Center of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Disease of Zhejiang University, Hangzhou 310009, Zhejiang Province, China
- Clinical Research Center of Hepatobiliary and Pancreatic Diseases of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
| | - Yang Tian
- Department of Hepatobiliary and Pancreatic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China
- Key Laboratory of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Tumor of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Research Center of Diagnosis and Treatment Technology for Hepatocellular Carcinoma of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Clinical Medicine Innovation Center of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Disease of Zhejiang University, Hangzhou 310009, Zhejiang Province, China
- Clinical Research Center of Hepatobiliary and Pancreatic Diseases of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
| | - Xiang Zhen
- Department of Hepatobiliary and Pancreatic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China
- Key Laboratory of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Tumor of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Research Center of Diagnosis and Treatment Technology for Hepatocellular Carcinoma of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Clinical Medicine Innovation Center of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Disease of Zhejiang University, Hangzhou 310009, Zhejiang Province, China
- Clinical Research Center of Hepatobiliary and Pancreatic Diseases of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
| | - De-Xing Kong
- Department of Hepatobiliary and Pancreatic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China
- School of Mathematical Sciences, Zhejiang University, Hangzhou 310027, Zhejiang Province, China
| | - Wei-Lin Wang
- Department of Hepatobiliary and Pancreatic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China
- Key Laboratory of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Tumor of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Research Center of Diagnosis and Treatment Technology for Hepatocellular Carcinoma of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Clinical Medicine Innovation Center of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Disease of Zhejiang University, Hangzhou 310009, Zhejiang Province, China
- Clinical Research Center of Hepatobiliary and Pancreatic Diseases of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
| | - Sheng Yan
- Department of Hepatobiliary and Pancreatic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China
- Key Laboratory of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Tumor of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Research Center of Diagnosis and Treatment Technology for Hepatocellular Carcinoma of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
- Clinical Medicine Innovation Center of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Disease of Zhejiang University, Hangzhou 310009, Zhejiang Province, China
- Clinical Research Center of Hepatobiliary and Pancreatic Diseases of Zhejiang Province, Hangzhou 310009, Zhejiang Province, China
| |
Collapse
|
192
|
Huang LL, Yu XP, Li JL, Lin HM, Kang NL, Jiang JJ, Zhu YY, Liu YR, Zeng DW. Effect of liver inflammation on accuracy of FibroScan device in assessing liver fibrosis stage in patients with chronic hepatitis B virus infection. World J Gastroenterol 2021; 27:641-653. [PMID: 33642834 PMCID: PMC7901051 DOI: 10.3748/wjg.v27.i7.641] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 12/30/2020] [Accepted: 01/13/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Transient elastography (FibroScan) is a new and non-invasive test, which has been widely recommended by the guidelines of chronic hepatitis B virus (HBV) management for assessing hepatic fibrosis staging. However, some confounders may affect the diagnostic accuracy of the FibroScan device in fibrosis staging.
AIM To evaluate the diagnostic value of the FibroScan device and the effect of hepatic inflammation on the accuracy of FibroScan in assessing the stage of liver fibrosis in patients with HBV infection.
METHODS The data of 416 patients with chronic HBV infection who accepted FibroScan, liver biopsy, clinical, and biological examination were collected from two hospitals retrospectively. Receiver operating characteristic (ROC) curves were used to analyze the diagnostic performance of FibroScan for assessing the stage of liver fibrosis. Any discordance in fibrosis staging by FibroScan and pathological scores was statistically analyzed. Logistic regression and ROC analyses were used to analyze the accuracy of FibroScan in assessing the stage of fibrosis in patients with different degrees of liver inflammation. A non-invasive model was constructed to predict the risk of misdiagnosis of fibrosis stage using FibroScan.
RESULTS In the overall cohort, the optimal diagnostic values of liver stiffness measurement (LSM) using FibroScan for significant fibrosis (≥ F2), severe fibrosis (≥ F3), and cirrhosis (F4) were 7.3 kPa [area under the curve (AUC) = 0.863], 9.7 kPa (AUC = 0.911), and 11.3 kPa (AUC = 0.918), respectively. The rate of misdiagnosis of fibrosis stage using FibroScan was 34.1% (142/416 patients). The group of patients who showed discordance between fibrosis staging using FibroScan and pathological scores had significantly higher alanine aminotransferase and aspartate aminotransferase levels, and a higher proportion of moderate to severe hepatic inflammation, compared with the group of patients who showed concordance in fibrosis staging between the two methods. Liver inflammation activity over 2 (OR = 3.53) was an independent risk factor for misdiagnosis of fibrosis stage using FibroScan. Patients with liver inflammation activity ≥ 2 showed higher LSM values using FibroScan and higher rates of misdiagnosis of fibrosis stage, whereas the diagnostic performance of FibroScan for different fibrosis stages was significantly lower than that in patients with inflammation activity < 2 (all P < 0.05). A non-invasive prediction model was established to assess the risk of misdiagnosis of fibrosis stage using FibroScan, and the AUC was 0.701.
CONCLUSION Liver inflammation was an independent risk factor affecting the diagnostic accuracy of FibroScan for fibrosis stage. A combination of other related non-invasive factors can predict the risk of misdiagnosis of fibrosis staging using FibroScan.
Collapse
Affiliation(s)
- Ling-Ling Huang
- Department of Hepatology, Hepatology Research Institute, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian Province, China
| | - Xue-Ping Yu
- Department of Infectious Diseases, The First Hospital of Quanzhou Affiliated to Fujian Medical University, Quanzhou 362000, Fujian Province, China
| | - Ju-Lan Li
- Department of Infectious Diseases, The First Hospital of Quanzhou Affiliated to Fujian Medical University, Quanzhou 362000, Fujian Province, China
| | - Hui-Ming Lin
- Department of Hepatology, Hepatology Research Institute, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian Province, China
| | - Na-Ling Kang
- Department of Hepatology, Hepatology Research Institute, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian Province, China
| | - Jia-Ji Jiang
- Department of Hepatology, Hepatology Research Institute, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian Province, China
| | - Yue-Yong Zhu
- Department of Hepatology, Hepatology Research Institute, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian Province, China
- Fujian Key Laboratory of Precision Medicine for Cancer, Fujian Key Laboratory of Laboratory Medicine, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian Province, China
| | - Yu-Rui Liu
- Department of Hepatology, Hepatology Research Institute, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian Province, China
| | - Da-Wu Zeng
- Department of Hepatology, Hepatology Research Institute, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian Province, China
| |
Collapse
|
193
|
Gabbiadini R, Zacharopoulou E, Furfaro F, Craviotto V, Zilli A, Gilardi D, Roda G, Loy L, Fiorino G, Peyrin-Biroulet L, Danese S, Allocca M. Application of Ultrasound Elastography for Assessing Intestinal Fibrosis in Inflammatory Bowel Disease: Fiction or Reality? Curr Drug Targets 2021; 22:347-355. [PMID: 33213341 DOI: 10.2174/1389450121666201119142919] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/07/2020] [Accepted: 09/27/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND Intestinal fibrosis and subsequent strictures represent an important burden in inflammatory bowel disease (IBD). Both the detection and evaluation of the degree of fibrosis in stricturing Crohn's disease (CD) are important when deciding the best therapeutic strategy (medical anti-inflammatory therapy, endoscopic dilation, surgery). Ultrasound elastography (USE) is a non-invasive technique that has been proposed in the field of IBD for evaluating intestinal stiffness as a biomarker of intestinal fibrosis. OBJECTIVE The aim of this review is to discuss the ability and current role of ultrasound elastography in the assessment of intestinal fibrosis. RESULTS AND CONCLUSION Data on USE in IBD are provided by pilot and proof-of-concept studies with small sample size. The first type of USE investigated was strain elastography, while shear wave elastography has been introduced recently. Despite the heterogeneity of the methods of the studies, USE has been proven to be able to assess intestinal fibrosis in patients with stricturing CD. However, before introducing this technique in current practice, further studies with larger sample sizes are needed. In addition, the use of homogeneous parameters, the assessment of reproducibility, and the identification of validated cut-off values are essential.
Collapse
Affiliation(s)
- Roberto Gabbiadini
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Eirini Zacharopoulou
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Federica Furfaro
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Vincenzo Craviotto
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Alessandra Zilli
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Daniela Gilardi
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Giulia Roda
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Laura Loy
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Gionata Fiorino
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Laurent Peyrin-Biroulet
- Department of Gastroenterology and Inserm U954, University Hospital of Nancy, Lorraine University, Nancy, France
| | - Silvio Danese
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| | - Mariangela Allocca
- Humanitas Clinical and Research Center - IRCCS -, via Manzoni 56, 20089 Rozzano (Mi), Italy
| |
Collapse
|
194
|
Lim Z, Whitaker T, DeColle K, Barrett K, Harlton C, Paskar L, Low G. Interobserver and Intraobserver Reliability of Hepatic Shear Wave Elastography and the Influence of Fasted Versus Nonfasted States in Healthy Volunteers. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:259-267. [PMID: 32686849 DOI: 10.1002/jum.15395] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 05/25/2020] [Accepted: 05/30/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES The primary objective of this study was to assess the effect of fasting versus ingestion of food and water on hepatic measurements by shear wave elastography (SWE) in healthy participants. The secondary objective was to assess inter- and intra-reader reliability of hepatic elastography in healthy participants. METHODS Twenty healthy participants were enrolled in this prospective study and underwent quantitative SWE under fasting conditions and after the ingestion of water and food and water. Two blinded sonographers each independently performed a total of 6 sessions of hepatic SWE in each participant. Sessions 1 to 3 were performed on day 0 and sessions 4 to 6 on day 7. Statistical tests used included the Wilcoxon signed ranks test, the intraclass correlation coefficient, and Bland-Altman plots. RESULTS There were no significant differences in hepatic SWE measurements after the ingestion of water versus the fasting state. Statistical significance was assessed as P < 0.05. The postprandial status had a statistically significant effect on hepatic SWE measurements at 1 hour (P = .04) but not at 3 hours (P = .08). By the intraclass correlation coefficient, there was poor-to-moderate inter-reader agreement and minimal-to-moderate intra-reader agreement. The median inter-reader difference in SWE measurements ranged from 0.66 to 0.96 kPa. The median intra-reader difference ranged from 0.43 to 0.55 kPa. CONCLUSIONS Our study shows that the ingestion of water has no effect on hepatic SWE measurements in healthy participants. The postprandial state had a significant effect on SWE measurements at 1 hour after ingestion but not at 3 hours. The inter-reader and intra-reader agreements were variable and moderate at best.
Collapse
Affiliation(s)
- Zerlene Lim
- Department of Radiology and Diagnostic Imaging, University of Alberta Hospital, Edmonton, Alberta, Canada
| | | | | | | | | | - Lee Paskar
- MIC Medical Imaging, Edmonton, Alberta, Canada
| | - Gavin Low
- Department of Radiology and Diagnostic Imaging, University of Alberta Hospital, Edmonton, Alberta, Canada
| |
Collapse
|
195
|
Koizumi Y, Hirooka M, Tanaka T, Watanabe T, Yoshida O, Tokumoto Y, Higaki T, Eguchi M, Abe M, Hiasa Y. Noninvasive ultrasound technique for assessment of liver fibrosis and cardiac function in Fontan-associated liver disease: diagnosis based on elastography and hepatic vein waveform type. J Med Ultrason (2001) 2021; 48:235-244. [PMID: 33417157 DOI: 10.1007/s10396-020-01078-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 12/16/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE Patients with a Fontan circulation tend to develop liver fibrosis, liver cirrhosis and even hepatocellular carcinoma. A noninvasive ultrasound technique for liver fibrosis and cardiac function assessment in Fontan-associated liver disease (FALD) is needed to evaluate disease progression in real time. This study aimed to evaluate whether hepatic vein (HV) waveform analysis and elastography could be alternative markers to cardiac index (CI) in patients with FALD and assess factors influencing elastography measurements in FALD cases. METHODS All patients underwent cardiac catheterization, B-mode ultrasound and ultrasound elastography measurement. Moreover, we measured serum markers related to fibrosis and examined HV blood flow using duplex Doppler ultrasonography. RESULTS Forty-three patients (median age, 17 years; interquartile range, 12-25 years; 29 men, 6 with liver biopsy) were enrolled. The real-time tissue elastography (RTE) value was significantly higher in patients who underwent surgery > 7 years prior, suggesting that this value probably reflects the liver fibrosis due to FALD from the early fibrosis stage. The ultrasound elastography did not significantly correlate with hemodynamic parameters. The area under the receiver operating curve for the diagnosis of CI < 2.2 L/min/m2 using HV waveform was superior to the results from elastography and calculated fibrosis indices. CONCLUSION HV waveform can be used as a noninvasive measurable surrogate marker for CI. The RTE value increased overtime after the operation and would reflect liver fibrosis. The combination of RTE and HV waveform type could be useful noninvasive tools to evaluate clinical conditions in FALD patients in real time.
Collapse
Affiliation(s)
- Yohei Koizumi
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Masashi Hirooka
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Takaaki Tanaka
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Takao Watanabe
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Osamu Yoshida
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Yoshio Tokumoto
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Takashi Higaki
- Molecule and Function, Department of Pediatrics, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Mariko Eguchi
- Department of Pediatrics, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Masanori Abe
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan
| | - Yoichi Hiasa
- Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon City, Ehime, 791-0295, Japan.
| |
Collapse
|
196
|
Chen SH, Lai HC, Chiang IP, Su WP, Lin CH, Kao JT, Chuang PH, Hsu WF, Wang HW, Chen HY, Huang GT, Peng CY. Performance of Acoustic Radiation Force Impulse Elastography for Staging Liver Fibrosis in Patients With Chronic Hepatitis C After Viral Eradication. Clin Infect Dis 2021; 70:114-122. [PMID: 30816416 DOI: 10.1093/cid/ciz161] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Accepted: 02/22/2019] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Data on noninvasive liver fibrosis staging after viral eradication are unclear. This histology-based study validated the performance of liver stiffness (LS) measurements after viral eradication. METHODS Consecutive participants with chronic hepatitis C (CHC) who received concomitant LS measurements through acoustic radiation force impulse (ARFI) elastography and percutaneous liver biopsy were prospectively screened and analyzed. RESULTS Of the 644 patients, 521 (80.9%) underwent a biopsy at treatment baseline, and the remaining 123 (19.1%) underwent a biopsy at 3 years (median; interquartile range, 0.1) after the sustained virological response (SVR) to pegylated interferon-based and direct-acting antiviral treatments. The proportions of histological fibrosis stages did not differ significantly between the pretreatment and post-SVR groups (P = .0615). However, the LS values differed significantly (P < .0001). The median LS values (presented as shear wave velocities in meters per second) were 1.51 (0.92) for the pretreatment group and 1.22 (0.77) for the post-SVR group. The cutoffs (areas under the receiver operating characteristic curve, obtained using the bootstrap method) to dichotomize between METAVIR fibrosis stage F1 versus stages F2-F4, F1-F2 versus F3-F4, and F1-F3 versus F4 were 1.47 (0.8333, 95% confidence interval [CI] 0.7981-0.8663), 1.81 (0.8763, 95% CI 0.8376-0.9107), and 1.86 (0.8811, 95% CI 0.8378-0.9179) in the pretreatment group, respectively, and 1.22 (0.7872, 95% CI 0.7001-0.8624), 1.59 (0.8808, 95% CI 0.8034-0.9422), and 1.75 (0.9018, 95% CI 0.8201-0.9644) in the post-SVR group, respectively. CONCLUSIONS The performance of LS measurements through ARFI elastography is promising to determine the liver fibrosis stage on necroinflammation-resolved histology in CHC after viral eradication.
Collapse
Affiliation(s)
- Sheng-Hung Chen
- Graduate Institute of Clinical Medical Science, Taichung, Taiwan.,School of Medicine, China Medical University, Taichung, Taiwan.,Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Hsueh-Chou Lai
- Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan.,College of Chinese Medicine, China Medical University, Taichung, Taiwan
| | - I-Ping Chiang
- Department of Pathology, China Medical University Hospital, Taichung, Taiwan
| | - Wen-Pang Su
- Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Chia-Hsin Lin
- Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Jung-Ta Kao
- School of Medicine, China Medical University, Taichung, Taiwan.,Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Po-Heng Chuang
- Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Wei-Fan Hsu
- Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Hung-Wei Wang
- Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Hung-Yao Chen
- Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Guan-Tarn Huang
- School of Medicine, China Medical University, Taichung, Taiwan.,Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| | - Cheng-Yuan Peng
- School of Medicine, China Medical University, Taichung, Taiwan.,Division of Hepatogastroenterology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan
| |
Collapse
|
197
|
Cebula M, Gruszczyńska K, Hartleb M, Baron J. Analysis of Point Shear Wave Elastography and Biochemical Markers for the Detection of Liver Fibrosis. ACTA ACUST UNITED AC 2021; 57:medicina57010040. [PMID: 33418917 PMCID: PMC7825115 DOI: 10.3390/medicina57010040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 12/30/2020] [Accepted: 01/04/2021] [Indexed: 11/16/2022]
Abstract
Background and Objectives: This work focuses on the possibility of using the point shear wave elastography (pSWE) method for detecting biochemical markers in diffuse liver diseases. Additionally, this study addresses the issue of the influence of ultrasound factors on the pSWE quality indicators of the obtained measurements. Materials and Methods: A pSWE examination was performed on 139 patients (69 female and 70 male) diagnosed with diffuse liver disease. The average age for all patients was 50.7 ± 15.0 years (female: 52.7 ± 15.2 years; male: 48.8 ± 14.6 years). Of these 139 patients, 65 met the inclusion criteria regarding biochemical parameters. The pSWE quality indicators were related to abnormalities found in B-mode ultrasound. Results: A strong positive correlation was found between the results of the pSWE and all biochemical indexes analysed, with the exception of age/platelet count (PLT), for which an average correlation was obtained. The greatest correlation was observed between the elastography and King’s Score index. There was no correlation observed between elastography and any of the analysed parameters or biochemical indexes considered. The pSWE measurements were impaired by factors such as thick soft tissue, uneven hepatic surface, hepatomegaly and female gender. No statistically significant difference in pSWE quality indicators parameters was found between disease entities. Conclusions: pSWE seems to be a complementary method for detecting biochemical indexes, but its results can be influenced by numerous factors.
Collapse
Affiliation(s)
- Maciej Cebula
- Department of Radiodiagnostics and Invasive Radiology, School of Medicine in Katowice, Medical University of Silesia, 40-752 Katowice, Poland;
- Correspondence:
| | - Katarzyna Gruszczyńska
- Department of Diagnostic Imaging, School of Medicine in Katowice, Medical University of Silesia, 40-752 Katowice, Poland;
| | - Marek Hartleb
- Department of Gastroenterology and Hepatology, School of Medicine in Katowice, Medical University of Silesia, 40-752 Katowice, Poland;
| | - Jan Baron
- Department of Radiodiagnostics and Invasive Radiology, School of Medicine in Katowice, Medical University of Silesia, 40-752 Katowice, Poland;
| |
Collapse
|
198
|
Miller T, Ying M, Sau Lan Tsang C, Huang M, Pang MYC. Reliability and Validity of Ultrasound Elastography for Evaluating Muscle Stiffness in Neurological Populations: A Systematic Review and Meta-Analysis. Phys Ther 2021; 101:5928445. [PMID: 33508855 DOI: 10.1093/ptj/pzaa188] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 06/04/2020] [Accepted: 09/10/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVE Ultrasound elastography is an emerging diagnostic technology used to investigate the biomechanical properties of the musculoskeletal system. The purpose of this study was to systematically review the psychometric properties of ultrasound elastography techniques for evaluating muscle stiffness in people with neurological conditions. METHODS A systematic search of MEDLINE, EMBASE, CINAHL, and Cochrane Library databases was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Using software, reviewers independently screened citations for inclusion. Peer-reviewed studies that evaluated in vivo muscle stiffness in people with neurological conditions and reported relevant psychometric properties were considered for inclusion. Twenty-one articles were included for final review. Data relevant to measurement technique, site, and neurological condition were extracted. The Consensus-Based Standards for the Selection of Health Measurement Instruments checklist was used to rate the methodological quality of included studies. The level of evidence for specific measurement outcomes was determined using a best-evidence synthesis approach. RESULTS Reliability varied across populations, ultrasound systems, and assessment conditions (ie, joint/body positions, active/passive muscle conditions, probe orientation), with most studies indicating moderate to good reliability (ICC = 0.5-0.9, n = 13). Meta-analysis results showed a good overall correlation across studies (r = 0.78, 95% confidence interval = 0.64-0.86), with no between-group difference based on population (Q1 = 0.00). Convergent validity was demonstrated by strong correlations between stiffness values and measures of spasticity (n = 5), functional motor recovery or impairment (n = 5), and grayscale or color histogram pixel intensities (n = 3). Discriminant or known-groups validity was also established for multiple studies and indicated either significant between-group differences in stiffness values (n = 12) or within-group differences between more and less affected limbs (n = 6). Responsiveness was observed in all intervention studies reporting posttreatment stiffness changes (n = 6). CONCLUSIONS Overall, ultrasound elastography techniques showed moderate reliability in evaluating in vivo muscle stiffness, good convergent validity with relevant clinical assessments, and good divergent validity in discriminating tissue changes within and between groups. IMPACT Ultrasound elastography has clinical utility in assessing muscle stiffness, monitoring its temporal changes, and measuring the response to intervention in people with neurological conditions.
Collapse
Affiliation(s)
- Tiev Miller
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong, S.A.R
| | - Michael Ying
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, S.A.R
| | - Charlotte Sau Lan Tsang
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong, S.A.R
| | - Meizhen Huang
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong, S.A.R
| | - Marco Y C Pang
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong, S.A.R
| |
Collapse
|
199
|
Nitta N, Yamakawa M, Hachiya H, Shiina T. A review of physical and engineering factors potentially affecting shear wave elastography. J Med Ultrason (2001) 2021; 48:403-414. [PMID: 34453649 PMCID: PMC8578095 DOI: 10.1007/s10396-021-01127-w] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Accepted: 07/15/2021] [Indexed: 01/01/2023]
Abstract
It has been recognized that tissue stiffness provides useful diagnostic information, as with palpation as a screening for diseases such as cancer. In recent years, shear wave elastography (SWE), a technique for evaluating and imaging tissue elasticity quantitatively and objectively in diagnostic imaging, has been put into practical use, and the amount of clinical knowledge about SWE has increased. In addition, some guidelines and review papers regarding technology and clinical applications have been published, and the status as a diagnostic technology is in the process of being established. However, there are still unclear points about the interpretation of shear wave speed (SWS) and converted elastic modulus in SWE. To clarify these, it is important to investigate the factors that affect the SWS and elastic modulus. Therefore, physical and engineering factors that potentially affect the SWS and elastic modulus are discussed in this review paper, based on the principles of SWE and a literature review. The physical factors include the propagation properties of shear waves, mechanical properties (viscoelasticity, nonlinearity, and anisotropy), and size and shape of target tissues. The engineering factors include the region of interest depth and signal processing. The aim of this review paper is not to provide an answer to the interpretation of SWS. It is to provide information for readers to formulate and verify the hypothesis for the interpretation. Therefore, methods to verify the hypothesis for the interpretation are also reviewed. Finally, studies on the safety of SWE are discussed.
Collapse
Affiliation(s)
- Naotaka Nitta
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki, 305-8564, Japan.
| | - Makoto Yamakawa
- Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Hiroyuki Hachiya
- School of Engineering, Tokyo Institute of Technology, Meguro, Tokyo, 152-8552, Japan
| | - Tsuyoshi Shiina
- Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| |
Collapse
|
200
|
Kapur S, Kalra N, Bhatia A, Duseja A, Das A, Dhiman RK, Chawla Y, Sandhu MS. Comparison of Elastography Point Quantification with Transient Elastography in Patients with Chronic Viral Hepatitis and Nonalcoholic Fatty Liver Disease: A Pilot Study. J Clin Exp Hepatol 2021; 11:21-29. [PMID: 33679045 PMCID: PMC7897856 DOI: 10.1016/j.jceh.2020.06.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Accepted: 06/14/2020] [Indexed: 12/12/2022] Open
Abstract
AIMS The objective of this study was to compare diagnostic accuracy of elastography point quantification (ElastPQ) with transient elastography (TE) and liver histology for measuring liver stiffness in patients with chronic viral hepatitis (CVH) and nonalcoholic fatty liver disease (NAFLD). METHODS Thirty-two patients with chronic liver disease (CVH and NAFLD) were evaluated by ElastPQ and TE within 7 days of liver biopsy. Within the CVH group, subgroup analysis was carried out in patients with end-stage renal disease (ESRD) and without ESRD. Area under the receiver operating characteristic (AUROC) curves were calculated for ElastPQ and TE. RESULTS There were 15 patients with CVH and 17 patients with NAFLD. In the CVH group, there were 8 patients with ESRD and 7 patients without ESRD. Taking liver histopathology as the gold standard, liver stiffness measurement by ElastPQ (ρ = 0.826;P < 0.0001) and TE (ρ = 0.649; P < 0.0001) correlated significantly with the stage of fibrosis. AUROCs of ElastPQ and TE for the diagnosis of any fibrosis (F ≥ 1), significant fibrosis (F ≥ 2), and advanced fibrosis (F ≥ 3) were 0.907, 0.959, 0.926 and 0.870, 0.770, 0.881, respectively, in both CVH and NAFLD groups. However, the accuracy of both these techniques was poor in patients with CVH and ESRD (AUROCs for ElastPQ and TE of 0.667 and 0.167 for the diagnosis of significant fibrosis, respectively, and 0.429 and 0.143 for the diagnosis of advanced fibrosis, respectively). The diagnostic accuracy of both ElastPQ and TE for detecting significant fibrosis was excellent in patients with NAFLD (AUROC of 1.000 and 0.936, respectively). ElastPQ was superior to TE in the diagnosis of significant fibrosis in the combined analysis (P = 0.0149) and in the CVH group (P = 0.0391), while both modalities were comparable in patients of the NAFLD group (P = 0.2539). CONCLUSION ElastPQ may be equally accurate as Fibroscan, and large prospective studies are required to validate the same.
Collapse
Affiliation(s)
- Savinay Kapur
- Departments of Radiodiagnosis and Imaging, Chandigarh, 160012, India
| | - Naveen Kalra
- Departments of Radiodiagnosis and Imaging, Chandigarh, 160012, India
| | - Anmol Bhatia
- Departments of Radiodiagnosis and Imaging, Chandigarh, 160012, India
| | - Ajay Duseja
- Departments of Hepatology, Chandigarh, 160012, India
| | - Ashim Das
- Departments of Histopathology, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh, 160012, India
| | | | - Yogesh Chawla
- Departments of Hepatology, Chandigarh, 160012, India
| | | |
Collapse
|