201
|
Genetically encoded reporters for hyperpolarized xenon magnetic resonance imaging. Nat Chem 2014; 6:629-34. [PMID: 24950334 DOI: 10.1038/nchem.1934] [Citation(s) in RCA: 161] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2013] [Accepted: 03/24/2014] [Indexed: 01/17/2023]
Abstract
Magnetic resonance imaging (MRI) enables high-resolution non-invasive observation of the anatomy and function of intact organisms. However, previous MRI reporters of key biological processes tied to gene expression have been limited by the inherently low molecular sensitivity of conventional (1)H MRI. This limitation could be overcome through the use of hyperpolarized nuclei, such as in the noble gas xenon, but previous reporters acting on such nuclei have been synthetic. Here, we introduce the first genetically encoded reporters for hyperpolarized (129)Xe MRI. These expressible reporters are based on gas vesicles (GVs), gas-binding protein nanostructures expressed by certain buoyant microorganisms. We show that GVs are capable of chemical exchange saturation transfer interactions with xenon, which enables chemically amplified GV detection at picomolar concentrations (a 100- to 10,000-fold improvement over comparable constructs for (1)H MRI). We demonstrate the use of GVs as heterologously expressed indicators of gene expression and chemically targeted exogenous labels in MRI experiments performed on living cells.
Collapse
|
202
|
Tetsumoto S, Takeda Y, Imai H, Kimura A, Jin Y, Nakanishi K, Maeda Y, Kuhara H, Tsujino K, Iwasaki T, Shigeta H, Kondo Y, Ito M, Minami T, Hirata H, Takahashi R, Kohmo S, Nagatomo I, Inoue K, Kida H, Kijima T, Tachibana I, Maeda N, Funahashi T, Shimomura I, Fujiwara H, Kumanogoh A. Validation of noninvasive morphological and diffusion imaging in mouse emphysema by micro-computed tomography and hyperpolarized (129)Xe magnetic resonance imaging. Am J Respir Cell Mol Biol 2014; 49:592-600. [PMID: 23668642 DOI: 10.1165/rcmb.2012-0350oc] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Animal disease models are pivotal in investigating the pathogenesis of emphysema and developing novel drugs, but the modalities to evaluate murine emphysema models have been of limited validity and sensitivity. In this study, we evaluated hyperpolarized (129)Xe magnetic resonance imaging (MRI) and micro-computed tomography (micro-CT) compared with traditional methods, such as plethysmography and histology. Elastase-treated mice and adiponectin knockout mice were used as murine emphysema models to evaluate these modalities. Three weeks after elastase administration, significant and heterogeneous emphysema was evaluated according to the mean linear intercept and plethysmography parameters. Notably, the distribution of low-density areas, as examined by micro-CT, correlated with the mean linear intercept and plethysmography parameters in whole lungs. These correlations were also observed in regional areas. Furthermore, we introduced hyperpolarized (129)Xe MRI, which can evaluate gas exchange between the alveoli and blood during spontaneous breathing. Parameters of gas exchange (fD) and alveolar size (Vs/Va) were significantly decreased in elastase-treated mice, and moderately correlated with the plethysmography parameters. Of importance, we could detect a decrease of the fD value in low-density areas with micro-CT, suggesting that gas exchange decreased in emphysematous lesions. Likewise, these parameters (fD and Vs/Va) were also decreased in adiponectin knockout mice, which exhibit emphysema with a homogeneous distribution. We demonstrated the feasibility of (129)Xe MRI and micro-CT in combination with traditional modalities. These noninvasive modalities provide complementary data that can be used for repeated estimations of regional gas exchange and lung morphology.
Collapse
Affiliation(s)
- Satoshi Tetsumoto
- 1 Department of Respiratory Medicine, Allergy, and Rheumatic Diseases, Graduate School of Medicine
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
203
|
Palaniappan KK, Francis MB, Pines A, Wemmer DE. Molecular Sensing Using Hyperpolarized Xenon NMR Spectroscopy. Isr J Chem 2014. [DOI: 10.1002/ijch.201300128] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
204
|
Nikolaou P, Coffey AM, Walkup LL, Gust BM, Whiting N, Newton H, Muradyan I, Dabaghyan M, Ranta K, Moroz GD, Rosen MS, Patz S, Barlow MJ, Chekmenev EY, Goodson BM. XeNA: an automated 'open-source' (129)Xe hyperpolarizer for clinical use. Magn Reson Imaging 2014; 32:541-50. [PMID: 24631715 DOI: 10.1016/j.mri.2014.02.002] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Revised: 01/30/2014] [Accepted: 02/02/2014] [Indexed: 11/28/2022]
Abstract
Here we provide a full report on the construction, components, and capabilities of our consortium's "open-source" large-scale (~1L/h) (129)Xe hyperpolarizer for clinical, pre-clinical, and materials NMR/MRI (Nikolaou et al., Proc. Natl. Acad. Sci. USA, 110, 14150 (2013)). The 'hyperpolarizer' is automated and built mostly of off-the-shelf components; moreover, it is designed to be cost-effective and installed in both research laboratories and clinical settings with materials costing less than $125,000. The device runs in the xenon-rich regime (up to 1800Torr Xe in 0.5L) in either stopped-flow or single-batch mode-making cryo-collection of the hyperpolarized gas unnecessary for many applications. In-cell (129)Xe nuclear spin polarization values of ~30%-90% have been measured for Xe loadings of ~300-1600Torr. Typical (129)Xe polarization build-up and T1 relaxation time constants were ~8.5min and ~1.9h respectively under our spin-exchange optical pumping conditions; such ratios, combined with near-unity Rb electron spin polarizations enabled by the high resonant laser power (up to ~200W), permit such high PXe values to be achieved despite the high in-cell Xe densities. Importantly, most of the polarization is maintained during efficient HP gas transfer to other containers, and ultra-long (129)Xe relaxation times (up to nearly 6h) were observed in Tedlar bags following transport to a clinical 3T scanner for MR spectroscopy and imaging as a prelude to in vivo experiments. The device has received FDA IND approval for a clinical study of chronic obstructive pulmonary disease subjects. The primary focus of this paper is on the technical/engineering development of the polarizer, with the explicit goals of facilitating the adaptation of design features and operative modes into other laboratories, and of spurring the further advancement of HP-gas MR applications in biomedicine.
Collapse
Affiliation(s)
- Panayiotis Nikolaou
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS), Nashville, TN, 37232, United States; Department of Chemistry & Biochemistry, Southern Illinois University, Carbondale, IL.
| | - Aaron M Coffey
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS), Nashville, TN, 37232, United States; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37235, United States
| | - Laura L Walkup
- Department of Chemistry & Biochemistry, Southern Illinois University, Carbondale, IL
| | - Brogan M Gust
- Department of Chemistry & Biochemistry, Southern Illinois University, Carbondale, IL
| | - Nicholas Whiting
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, NG7 2RD, Nottingham, UK
| | - Hayley Newton
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, NG7 2RD, Nottingham, UK
| | - Iga Muradyan
- Department of Radiology, Brigham & Women's Hospital and Harvard Medical School, Boston, MA
| | - Mikayel Dabaghyan
- Department of Radiology, Brigham & Women's Hospital and Harvard Medical School, Boston, MA
| | - Kaili Ranta
- Department of Physics, Southern Illinois University, Carbondale, IL
| | - Gregory D Moroz
- Graduate School Central Research Shop, Southern Illinois University, Carbondale, IL
| | - Matthew S Rosen
- MGH/A.A. Martinos Center for Biomedical Imaging, Boston, MA; Department of Physics, Harvard University, Cambridge, MA
| | - Samuel Patz
- Department of Radiology, Brigham & Women's Hospital and Harvard Medical School, Boston, MA
| | - Michael J Barlow
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, NG7 2RD, Nottingham, UK
| | - Eduard Y Chekmenev
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS), Nashville, TN, 37232, United States; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37235, United States; Department of Biochemistry, Vanderbilt University, Nashville, TN, 37205, United States
| | - Boyd M Goodson
- Department of Chemistry & Biochemistry, Southern Illinois University, Carbondale, IL.
| |
Collapse
|
205
|
Hövener JB, Schwaderlapp N, Borowiak R, Lickert T, Duckett SB, Mewis RE, Adams RW, Burns MJ, Highton LAR, Green GGR, Olaru A, Hennig J, von Elverfeldt D. Toward biocompatible nuclear hyperpolarization using signal amplification by reversible exchange: quantitative in situ spectroscopy and high-field imaging. Anal Chem 2014; 86:1767-74. [PMID: 24397559 PMCID: PMC3929132 DOI: 10.1021/ac403653q] [Citation(s) in RCA: 96] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 01/07/2014] [Indexed: 11/29/2022]
Abstract
Signal amplification by reversible exchange (SABRE) of a substrate and parahydrogen at a catalytic center promises to overcome the inherent insensitivity of magnetic resonance. In order to apply the new approach to biomedical applications, there is a need to develop experimental equipment, in situ quantification methods, and a biocompatible solvent. We present results detailing a low-field SABRE polarizer which provides well-controlled experimental conditions, defined spins manipulations, and which allows in situ detection of thermally polarized and hyperpolarized samples. We introduce a method for absolute quantification of hyperpolarization yield in situ by means of a thermally polarized reference. A maximum signal-to-noise ratio of ∼10(3) for 148 μmol of substance, a signal enhancement of 10(6) with respect to polarization transfer field of SABRE, or an absolute (1)H-polarization level of ≈10(-2) is achieved. In an important step toward biomedical application, we demonstrate (1)H in situ NMR as well as (1)H and (13)C high-field MRI using hyperpolarized pyridine (d3) and (13)C nicotinamide in pure and 11% ethanol in aqueous solution. Further increase of hyperpolarization yield, implications of in situ detection, and in vivo application are discussed.
Collapse
Affiliation(s)
- Jan-Bernd Hövener
- German
Consortium for Cancer Research (DKTK), Heidelberg, Germany
- Medical
Physics, Department of Radiology, University
Medical Center Freiburg, 79098 Freiburg, Germany
- German
Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Niels Schwaderlapp
- Medical
Physics, Department of Radiology, University
Medical Center Freiburg, 79098 Freiburg, Germany
| | - Robert Borowiak
- German
Consortium for Cancer Research (DKTK), Heidelberg, Germany
- Medical
Physics, Department of Radiology, University
Medical Center Freiburg, 79098 Freiburg, Germany
- German
Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Thomas Lickert
- Medical
Physics, Department of Radiology, University
Medical Center Freiburg, 79098 Freiburg, Germany
| | - Simon B. Duckett
- Centre
for Hyperpolarisation in Magnetic Resonance, University of York, York, YO10 5DD, U.K.
| | - Ryan E. Mewis
- Centre
for Hyperpolarisation in Magnetic Resonance, University of York, York, YO10 5DD, U.K.
| | - Ralph W. Adams
- Centre
for Hyperpolarisation in Magnetic Resonance, University of York, York, YO10 5DD, U.K.
| | - Michael J. Burns
- Centre
for Hyperpolarisation in Magnetic Resonance, University of York, York, YO10 5DD, U.K.
| | - Louise A. R. Highton
- Centre
for Hyperpolarisation in Magnetic Resonance, University of York, York, YO10 5DD, U.K.
| | - Gary G. R. Green
- Centre
for Hyperpolarisation in Magnetic Resonance, University of York, York, YO10 5DD, U.K.
| | - Alexandra Olaru
- Centre
for Hyperpolarisation in Magnetic Resonance, University of York, York, YO10 5DD, U.K.
| | - Jürgen Hennig
- Medical
Physics, Department of Radiology, University
Medical Center Freiburg, 79098 Freiburg, Germany
| | - Dominik von Elverfeldt
- Medical
Physics, Department of Radiology, University
Medical Center Freiburg, 79098 Freiburg, Germany
| |
Collapse
|
206
|
Pike D, Lindenmaier TJ, Sin DD, Parraga G. Imaging evidence of the relationship between atherosclerosis and chronic obstructive pulmonary disease. ACTA ACUST UNITED AC 2014. [DOI: 10.2217/iim.13.70] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
207
|
Nikolaou P, Coffey AM, Walkup LL, Gust BM, LaPierre CD, Koehnemann E, Barlow MJ, Rosen MS, Goodson BM, Chekmenev EY. A 3D-printed high power nuclear spin polarizer. J Am Chem Soc 2014; 136:1636-42. [PMID: 24400919 DOI: 10.1021/ja412093d] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Three-dimensional printing with high-temperature plastic is used to enable spin exchange optical pumping (SEOP) and hyperpolarization of xenon-129 gas. The use of 3D printed structures increases the simplicity of integration of the following key components with a variable temperature SEOP probe: (i) in situ NMR circuit operating at 84 kHz (Larmor frequencies of (129)Xe and (1)H nuclear spins), (ii) <0.3 nm narrowed 200 W laser source, (iii) in situ high-resolution near-IR spectroscopy, (iv) thermoelectric temperature control, (v) retroreflection optics, and (vi) optomechanical alignment system. The rapid prototyping endowed by 3D printing dramatically reduces production time and expenses while allowing reproducibility and integration of "off-the-shelf" components and enables the concept of printing on demand. The utility of this SEOP setup is demonstrated here to obtain near-unity (129)Xe polarization values in a 0.5 L optical pumping cell, including ∼74 ± 7% at 1000 Torr xenon partial pressure, a record value at such high Xe density. Values for the (129)Xe polarization exponential build-up rate [(3.63 ± 0.15) × 10(-2) min(-1)] and in-cell (129)Xe spin-lattice relaxation time (T1 = 2.19 ± 0.06 h) for 1000 Torr Xe were in excellent agreement with the ratio of the gas-phase polarizations for (129)Xe and Rb (PRb ∼ 96%). Hyperpolarization-enhanced (129)Xe gas imaging was demonstrated with a spherical phantom following automated gas transfer from the polarizer. Taken together, these results support the development of a wide range of chemical, biochemical, material science, and biomedical applications.
Collapse
Affiliation(s)
- Panayiotis Nikolaou
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS) , Nashville, Tennessee 37232, United States
| | | | | | | | | | | | | | | | | | | |
Collapse
|
208
|
Leung G, Norquay G, Schulte RF, Wild JM. Radiofrequency pulse design for the selective excitation of dissolved 129Xe. Magn Reson Med 2014; 73:21-30. [PMID: 24395490 DOI: 10.1002/mrm.25089] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Revised: 10/30/2013] [Accepted: 11/27/2013] [Indexed: 12/25/2022]
Abstract
PURPOSE To optimize radiofrequency (RF) pulses for the selective excitation of dissolved phase (129)Xe that take into account the very short T2*, while simultaneously, minimally exciting the much larger gas signal. METHODS Numerical simulations of Shinnar le-Roux pulses and binomial coefficient composite-element pulses were performed and experimentally implemented on a 1.5 Tesla (T) clinical scanner. These were compared with pulses commonly used for short T2* imaging from the literature. The pulses were then experimentally tested in vivo with healthy volunteers inhaling hyperpolarized (129)Xe using nuclear MR spectroscopy on a 1.5T clinical scanner. RESULTS Standard RF excitation pulses inadvertently excite the gas compartment, or are long enough that the T2* of the dissolved compartment deteriorates the received signal. Amplitude modulated binomial composite pulses perform well being short and having high selectivity, however, deteriorate at high amplifier gain setting. Composite pulses using pulse width modulation provide the desired frequency response even in these nonlinear, high gain regimes. CONCLUSION Composite pulses provide a means of very narrow band frequency selectivity in a short duration pulse that is well suited to dissolved (129)Xe imaging. Pulse width modulation maintains the desired frequency response even in the presence of amplitude distortion.
Collapse
Affiliation(s)
- General Leung
- Unit of Academic Radiology, University of Sheffield, Sheffield, United Kingdom
| | - Graham Norquay
- Unit of Academic Radiology, University of Sheffield, Sheffield, United Kingdom
| | | | - Jim M Wild
- Unit of Academic Radiology, University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
209
|
Six JS, Hughes-Riley T, Lilburn DM, Dorkes AC, Stupic KF, Shaw DE, Morris PG, Hall IP, Pavlovskaya GE, Meersmann T. Pulmonary MRI contrast using Surface Quadrupolar Relaxation (SQUARE) of hyperpolarized (83)Kr. Magn Reson Imaging 2014; 32:48-53. [PMID: 24144493 PMCID: PMC3898897 DOI: 10.1016/j.mri.2013.08.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2013] [Revised: 08/08/2013] [Accepted: 08/20/2013] [Indexed: 11/24/2022]
Abstract
Hyperpolarized (83)Kr has previously been demonstrated to enable MRI contrast that is sensitive to the chemical composition of the surface in a porous model system. Methodological advances have lead to a substantial increase in the (83)Kr hyperpolarization and the resulting signal intensity. Using the improved methodology for spin exchange optical pumping of isotopically enriched (83)Kr, internal anatomical details of ex vivo rodent lung were resolved with hyperpolarized (83)Kr MRI after krypton inhalation. Different (83)Kr relaxation times were found between the main bronchi and the parenchymal regions in ex vivo rat lungs. The T1 weighted hyperpolarized (83)Kr MRI provided a first demonstration of surface quadrupolar relaxation (SQUARE) pulmonary MRI contrast.
Collapse
Affiliation(s)
- Joseph S. Six
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham NG7 2RD, UK
- School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK
| | - Theodore Hughes-Riley
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham NG7 2RD, UK
- School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK
| | - David M.L. Lilburn
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham NG7 2RD, UK
- School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK
| | - Alan C. Dorkes
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham NG7 2RD, UK
- School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD, UK
| | - Karl F. Stupic
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham NG7 2RD, UK
- School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK
| | - Dominick E. Shaw
- Nottingham Respiratory Research Unit, University of Nottingham, Nottingham NG5 1PB, UK
| | - Peter G. Morris
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham NG7 2RD, UK
- School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD, UK
| | - Ian P. Hall
- School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK
| | - Galina E. Pavlovskaya
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham NG7 2RD, UK
- School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK
| | - Thomas Meersmann
- Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham NG7 2RD, UK
- School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK
| |
Collapse
|
210
|
Pravdivtsev AN, Yurkovskaya AV, Lukzen NN, Vieth HM, Ivanov KL. Exploiting level anti-crossings (LACs) in the rotating frame for transferring spin hyperpolarization. Phys Chem Chem Phys 2014; 16:18707-19. [DOI: 10.1039/c4cp01445f] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A method of transferring hyperpolarization among scalar-coupled nuclear spins is proposed, which is based on spin mixing at energy level anti-crossing (LAC) regions.
Collapse
Affiliation(s)
- Andrey N. Pravdivtsev
- International Tomography Center
- Siberian Branch of the Russian Academy of Science
- Novosibirsk, Russia
- Novosibirsk State University
- Novosibirsk, Russia
| | - Alexandra V. Yurkovskaya
- International Tomography Center
- Siberian Branch of the Russian Academy of Science
- Novosibirsk, Russia
- Novosibirsk State University
- Novosibirsk, Russia
| | - Nikita N. Lukzen
- International Tomography Center
- Siberian Branch of the Russian Academy of Science
- Novosibirsk, Russia
- Novosibirsk State University
- Novosibirsk, Russia
| | - Hans-Martin Vieth
- Institut für Experimentalphysik
- Freie Universität Berlin
- Berlin, Germany
| | - Konstantin L. Ivanov
- International Tomography Center
- Siberian Branch of the Russian Academy of Science
- Novosibirsk, Russia
- Novosibirsk State University
- Novosibirsk, Russia
| |
Collapse
|
211
|
Giraudeau P, Frydman L. Ultrafast 2D NMR: an emerging tool in analytical spectroscopy. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2014; 7:129-61. [PMID: 25014342 PMCID: PMC5040491 DOI: 10.1146/annurev-anchem-071213-020208] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Two-dimensional nuclear magnetic resonance (2D NMR) spectroscopy is widely used in chemical and biochemical analyses. Multidimensional NMR is also witnessing increased use in quantitative and metabolic screening applications. Conventional 2D NMR experiments, however, are affected by inherently long acquisition durations, arising from their need to sample the frequencies involved along their indirect domains in an incremented, scan-by-scan nature. A decade ago, a so-called ultrafast (UF) approach was proposed, capable of delivering arbitrary 2D NMR spectra involving any kind of homo- or heteronuclear correlation, in a single scan. During the intervening years, the performance of this subsecond 2D NMR methodology has been greatly improved, and UF 2D NMR is rapidly becoming a powerful analytical tool experiencing an expanded scope of applications. This review summarizes the principles and main developments that have contributed to the success of this approach and focuses on applications that have been recently demonstrated in various areas of analytical chemistry--from the real-time monitoring of chemical and biochemical processes, to extensions in hyphenated techniques and in quantitative applications.
Collapse
Affiliation(s)
- Patrick Giraudeau
- Chimie et Interdisciplinarité: Synthèse, Analyse, Modélisation, UMR 6230, Université de Nantes, 44322 Nantes Cedex 03, France;
| | | |
Collapse
|
212
|
Pravdivtsev AN, Yurkovskaya AV, Vieth HM, Ivanov KL. Coherent transfer of nuclear spin polarization in field-cycling NMR experiments. J Chem Phys 2013; 139:244201. [DOI: 10.1063/1.4848699] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
213
|
Couch MJ, Ball IK, Li T, Fox MS, Littlefield SL, Biman B, Albert MS. Pulmonary Ultrashort Echo Time19F MR Imaging with Inhaled Fluorinated Gas Mixtures in Healthy Volunteers: Feasibility. Radiology 2013; 269:903-9. [DOI: 10.1148/radiol.13130609] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
214
|
Abstract
This article establishes the basic mathematical models and the principles and assumptions used for inert gas transfer within body tissues-first, for a single compartment model and then for a multicompartment model. From these, and other more complex mathematical models, the transport of inert gases between lungs, blood, and other tissues is derived and compared to known experimental studies in both animals and humans. Some aspects of airway and lung transfer are particularly important to the uptake and elimination of inert gases, and these aspects of gas transport in tissues are briefly described. The most frequently used inert gases are those that are administered in anesthesia, and the specific issues relating to the uptake, transport, and elimination of these gases and vapors are dealt with in some detail showing how their transfer depends on various physical and chemical attributes, particularly their solubilities in blood and different tissues. Absorption characteristics of inert gases from within gas cavities or tissue bubbles are described, and the effects other inhaled gas mixtures have on the composition of these gas cavities are discussed. Very brief consideration is given to the effects of hyper- and hypobaric conditions on inert gas transport.
Collapse
Affiliation(s)
- A Barry Baker
- Department of Anaesthesia, University of Sydney, NSW, Australia.
| | | |
Collapse
|
215
|
Kirby M, Parraga G. Pulmonary functional imaging using hyperpolarized noble gas MRI: six years of start-up experience at a single site. Acad Radiol 2013; 20:1344-56. [PMID: 24119346 DOI: 10.1016/j.acra.2013.02.020] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2012] [Revised: 01/31/2013] [Accepted: 02/01/2013] [Indexed: 12/01/2022]
Abstract
RATIONALE AND OBJECTIVES In this review, we summarize our experience evaluating pulmonary function in 330 different subjects using hyperpolarized noble gas magnetic resonance imaging (MRI) after enrollment and screening of >1100 subjects with and without respiratory disease during the period February 1, 2006, through November 1, 2012. MATERIALS AND METHODS We discuss the feasibility of hyperpolarized gas MRI research in a small nonhospital research unit and provide an overview of our experience since we initiated patient-based studies. We also discuss the importance of infrastructure support, collaboration, research trainees, and a large and willing patient population that helped to advance the research and technological deliverables. A summary of patient safety and tolerability, key feasibility, and research milestones is provided, as well as a roadmap for future studies. RESULTS Hyperpolarized (3)He and (129)Xe gas MRI is feasible at smaller centers without significant human resources for large and small longitudinal studies by virtue of its excellent patient safety and tolerability, the speed with which images can be acquired and quantitatively analyzed and the high spatial-temporal dynamics of the method that allows for acute and chronic therapy studies. CONCLUSIONS The hyperpolarized noble gas MRI community's highly collaborative efforts and motivation to further the development and application of this tool has resulted in a moment-of-opportunity to translate the method clinically to provide an improved understanding of pulmonary disease. There are, as well, new and unprecedented opportunities for the evaluation of disease progression and to help develop the new treatments and interventions critically required for chronic pulmonary disease.
Collapse
Affiliation(s)
- Miranda Kirby
- Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Canada, N6A 5K8; Department of Medical Biophysics, London, Canada
| | | |
Collapse
|
216
|
Thien F. Measuring and imaging small airways dysfunction in asthma. Asia Pac Allergy 2013; 3:224-30. [PMID: 24260727 PMCID: PMC3826607 DOI: 10.5415/apallergy.2013.3.4.224] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Accepted: 10/04/2013] [Indexed: 11/26/2022] Open
Abstract
Asthma is a chronic inflammatory disorder of the airways causing typical symptoms, and the diagnosis is supported by evidence of airflow obstruction which is variable, reversible or inducible. However, standard assessment of lung function with spirometry does not measure dysfunction in small airways which are < 2 mm in diameter towards the periphery of the lung. These airways make only a small contribution to airway resistance under normal circumstances. Nevertheless, there is mounting evidence that pathology and dysfunction in these small airways are implicated in the pathogenesis and natural history of asthma. Using forced oscillation and the multibreath nitrogen washout techniques, uneven ventilation (ventilation heterogeneity) due to small airways dysfunction has been shown to be an important marker of asthma disease activity, even in the absence of abnormalities in standard spirometric measurements. Recent advances in imaging research, particularly with hyperpolarised gas magnetic resonance imaging, have also given insights into the significance and dynamic nature of ventilation heterogeneity in asthma. The challenge is to integrate these new physiological and imaging insights to further our understanding of asthma and facilitate potential new treatments.
Collapse
Affiliation(s)
- Francis Thien
- Department of Respiratory Medicine, Eastern Health and Monash University, Box Hill Hospital, Box Hill, VIC 3128, Australia
| |
Collapse
|
217
|
Nakamura K, Kondoh Y, Kinoshita T. Hyperpolarized (129)Xe spectra from C6 glioma cells implanted in rat brains. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:2972-5. [PMID: 24110351 DOI: 10.1109/embc.2013.6610164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Tumor cell density is dramatically different from normal tissue. Since the chemical shift of hyperpolarized (129)Xe reflects local cell structure, we hypothesized that the presence of tumor cells could potentially be determined from (129)Xe spectra. Spectra and washout decay rate from three rats implanted with C6 glioma cells were compared with eight control rats. No significant differences between normal and tumor spectra were observed. The decay time of the C6 rats (mean 13.5 ± 1.9 s) was not significantly different from normal rats (mean 11.7 ± 1.8 s). These results suggest that hyperpolarized Xe may not be a superior tracer for detection of tumor cells in the intact brain.
Collapse
|
218
|
Abstract
A better understanding of the anatomic structure and physiological function of the lung is fundamental to understanding the pathogenesis of pulmonary disease and how to design and deliver better treatments and measure response to intervention. Magnetic resonance imaging (MRI) with the hyperpolarised noble gases helium-3 ((3)He) and xenon-129 ((129)Xe) provides both structural and functional pulmonary measurements, and because it does not require the use of x-rays or other ionising radiation, offers the potential for intensive serial and longitudinal studies in paediatric patients. These facts are particularly important in the evaluation of chronic lung diseases such as asthma and cystic fibrosis- both of which can be considered paediatric respiratory diseases with unmet therapy needs. This review discusses MRI-based imaging methods with a focus on hyperpolarised gas MRI. We also discuss the strengths and limitations as well as the future work required for clinical translation towards paediatric respiratory disease.
Collapse
Affiliation(s)
- Miranda Kirby
- Imaging Research Laboratories, Robarts Research Institute, London, Canada.
| | | | | |
Collapse
|
219
|
Lilburn DML, Hughes-Riley T, Six JS, Stupic KF, Shaw DE, Pavlovskaya GE, Meersmann T. Validating excised rodent lungs for functional hyperpolarized xenon-129 MRI. PLoS One 2013; 8:e73468. [PMID: 24023683 PMCID: PMC3758272 DOI: 10.1371/journal.pone.0073468] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Accepted: 07/21/2013] [Indexed: 12/15/2022] Open
Abstract
Ex vivo rodent lung models are explored for physiological measurements of respiratory function with hyperpolarized (hp) (129)Xe MRI. It is shown that excised lung models allow for simplification of the technical challenges involved and provide valuable physiological insights that are not feasible using in vivo MRI protocols. A custom designed breathing apparatus enables MR images of gas distribution on increasing ventilation volumes of actively inhaled hp (129)Xe. Straightforward hp (129)Xe MRI protocols provide residual lung volume (RV) data and permit for spatially resolved tracking of small hp (129)Xe probe volumes during the inhalation cycle. Hp (129)Xe MRI of lung function in the excised organ demonstrates the persistence of post mortem airway responsiveness to intravenous methacholine challenges. The presented methodology enables physiology of lung function in health and disease without additional regulatory approval requirements and reduces the technical and logistical challenges with hp gas MRI experiments. The post mortem lung functional data can augment histological measurements and should be of interest for drug development studies.
Collapse
Affiliation(s)
- David M. L. Lilburn
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Theodore Hughes-Riley
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Joseph S. Six
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Karl F. Stupic
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Dominick E. Shaw
- Nottingham Respiratory Research Unit, Nottingham City Hospital, Nottingham, United Kingdom
| | - Galina E. Pavlovskaya
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Thomas Meersmann
- Sir Peter Mansfield Magnetic Resonance Centre, School of Clinical Sciences, University of Nottingham, Nottingham, United Kingdom
| |
Collapse
|
220
|
Mugler JP, Altes TA. Hyperpolarized 129Xe MRI of the human lung. J Magn Reson Imaging 2013; 37:313-31. [PMID: 23355432 DOI: 10.1002/jmri.23844] [Citation(s) in RCA: 240] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2012] [Accepted: 08/29/2012] [Indexed: 11/07/2022] Open
Abstract
By permitting direct visualization of the airspaces of the lung, magnetic resonance imaging (MRI) using hyperpolarized gases provides unique strategies for evaluating pulmonary structure and function. Although the vast majority of research in humans has been performed using hyperpolarized (3)He, recent contraction in the supply of (3)He and consequent increases in price have turned attention to the alternative agent, hyperpolarized (129) Xe. Compared to (3)He, (129)Xe yields reduced signal due to its smaller magnetic moment. Nonetheless, taking advantage of advances in gas-polarization technology, recent studies in humans using techniques for measuring ventilation, diffusion, and partial pressure of oxygen have demonstrated results for hyperpolarized (129)Xe comparable to those previously demonstrated using hyperpolarized (3)He. In addition, xenon has the advantage of readily dissolving in lung tissue and blood following inhalation, which makes hyperpolarized (129)Xe particularly attractive for exploring certain characteristics of lung function, such as gas exchange and uptake, which cannot be accessed using (3)He. Preliminary results from methods for imaging (129) Xe dissolved in the human lung suggest that these approaches will provide new opportunities for quantifying relationships among gas delivery, exchange, and transport, and thus show substantial potential to broaden our understanding of lung disease. Finally, recent changes in the commercial landscape of the hyperpolarized-gas field now make it possible for this innovative technology to move beyond the research laboratory.
Collapse
Affiliation(s)
- John P Mugler
- Center for In-vivo Hyperpolarized Gas MR Imaging, Department of Radiology and Medical Imaging, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA.
| | | |
Collapse
|
221
|
Berganza CJ, Zhang JH. The role of helium gas in medicine. Med Gas Res 2013; 3:18. [PMID: 23916029 PMCID: PMC3751721 DOI: 10.1186/2045-9912-3-18] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Accepted: 07/25/2013] [Indexed: 01/04/2023] Open
Abstract
The noble gas helium has many applications owing to its distinct physical and chemical characteristics, namely: its low density, low solubility, and high thermal conductivity. Chiefly, the abundance of studies in medicine relating to helium are concentrated in its possibility of being used as an adjunct therapy in a number of respiratory ailments such as asthma exacerbation, COPD, ARDS, croup, and bronchiolitis. Helium gas, once believed to be biologically inert, has been recently shown to be beneficial in protecting the myocardium from ischemia by various mechanisms. Though neuroprotection of brain tissue has been documented, the mechanism by which it does so has yet to be made clear. Surgeons are exploring using helium instead of carbon dioxide to insufflate the abdomen of patients undergoing laparoscopic abdominal procedures due to its superiority in preventing respiratory acidosis in patients with comorbid conditions that cause carbon dioxide retention. Newly discovered applications in Pulmonary MRI radiology and imaging of organs in very fine detail using Helium Ion Microscopy has opened exciting new possibilities for the use of helium gas in technologically advanced fields of medicine.
Collapse
Affiliation(s)
- Carlos J Berganza
- Departments of Neurosurgery and Physiology, Loma Linda University, Loma Linda California, USA.
| | | |
Collapse
|
222
|
Kiryutin AS, Yurkovskaya AV, Kaptein R, Vieth HM, Ivanov KL. Evidence for Coherent Transfer of para-Hydrogen-Induced Polarization at Low Magnetic Fields. J Phys Chem Lett 2013; 4:2514-2519. [PMID: 26704425 DOI: 10.1021/jz401210m] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We have investigated the mechanism of para-hydrogen-induced polarization (PHIP) transfer from the original strongly aligned protons to other nuclei at low external magnetic fields. Although it is known that PHIP is efficiently transferred at low fields, the nature of the transfer mechanism, that is, coherent spin mixing or cross-relaxation, is not well established. Polarization transfer kinetics for individual protons of styrene was, for the first time, measured and modeled theoretically. Pronounced oscillations were observed indicating a coherent transfer mechanism. Spin coherences were excited by passing through an avoided level crossing of the nuclear spin energy levels. Transfer at avoided level crossings is selective with respect to spin order. Our work provides evidence that the coherent PHIP transfer mechanism is dominant at low magnetic fields.
Collapse
Affiliation(s)
- Alexey S Kiryutin
- International Tomography Center SB RAS , Novosibirsk 630090, Russia
- Novosibirsk State University , Novosibirsk 630090, Russia
| | - Alexandra V Yurkovskaya
- International Tomography Center SB RAS , Novosibirsk 630090, Russia
- Novosibirsk State University , Novosibirsk 630090, Russia
| | - Robert Kaptein
- Novosibirsk State University , Novosibirsk 630090, Russia
- Utrecht University , NL-3584 CH Utrecht, The Netherlands
| | | | - Konstantin L Ivanov
- International Tomography Center SB RAS , Novosibirsk 630090, Russia
- Novosibirsk State University , Novosibirsk 630090, Russia
| |
Collapse
|
223
|
Witte C, Schröder L. NMR of hyperpolarised probes. NMR IN BIOMEDICINE 2013; 26:788-802. [PMID: 23033215 DOI: 10.1002/nbm.2873] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2012] [Revised: 07/23/2012] [Accepted: 08/29/2012] [Indexed: 06/01/2023]
Abstract
Increasing the sensitivity of NMR experiments is an ongoing field of research to help realise the exquisite molecular specificity of this technique. Hyperpolarisation of various nuclei is a powerful approach that enables the use of NMR for molecular and cellular imaging. Substantial progress has been achieved over recent years in terms of both tracer preparation and detection schemes. This review summarises recent developments in probe design and optimised signal encoding, and promising results in sensitive disease detection and efficient therapeutic monitoring. The different methods have great potential to provide molecular specificity not available by other diagnostic modalities.
Collapse
Affiliation(s)
- Christopher Witte
- ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie, Berlin, Germany
| | | |
Collapse
|
224
|
Mulder WJM, McMahon MT, Nicolay K. The evolution of MRI probes: from the initial development to state-of-the-art applications. NMR IN BIOMEDICINE 2013; 26:725-727. [PMID: 23784954 DOI: 10.1002/nbm.2976] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Accepted: 04/20/2013] [Indexed: 06/02/2023]
|
225
|
Rudavets MG. Effective dipole-dipole interactions in critical nanofluids. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2013; 230:10-18. [PMID: 23416706 DOI: 10.1016/j.jmr.2013.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2012] [Revised: 12/21/2012] [Accepted: 01/07/2013] [Indexed: 06/01/2023]
Abstract
It is long known that the effective dipole-dipole coupling is averaged to zero when the spin carrying atoms are involved in a fast random movement in an unconfined fluid. The presented theory shows that if (i) the fluid is confined in long closed nanotubes, (ii) the fluid is in the vicinity of the second order phase transition, and (iii) the mobility of the spin carrying atoms of the fluid is high then the effective dipole-dipole coupling of the fluid is characterized by a finite global value that is independent of the spacing between all the atoms and independent of the length of the nanotubes. We report how the two regimes of the strong and weak effective dipole-dipole couplings in the vicinity and far from the critical point (CP), respectively, can be discriminated in the NMR experiments. Strong enhancements of the signals in the free induction decay, the line shape and the superradiation that result from the abnormally large effective dipole-dipole coupling in the vicinity of the CP are predicted.
Collapse
Affiliation(s)
- M G Rudavets
- Institute of Problems of Chemical Physics, RAS, Chernogolovka, Moscow Region 142432, Russia.
| |
Collapse
|
226
|
Cassidy MC, Chan HR, Ross BD, Bhattacharya PK, Marcus CM. In vivo magnetic resonance imaging of hyperpolarized silicon particles. NATURE NANOTECHNOLOGY 2013; 8:363-368. [PMID: 23644571 DOI: 10.1038/nnano.2013.65] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2012] [Accepted: 03/19/2013] [Indexed: 06/02/2023]
Abstract
Silicon-based micro- and nanoparticles have gained popularity in a wide range of biomedical applications due to their biocompatibility and biodegradability in vivo, as well as their flexible surface chemistry, which allows drug loading, functionalization and targeting. Here, we report direct in vivo imaging of hyperpolarized (29)Si nuclei in silicon particles by magnetic resonance imaging. Natural physical properties of silicon provide surface electronic states for dynamic nuclear polarization, extremely long depolarization times, insensitivity to the in vivo environment or particle tumbling, and surfaces favourable for functionalization. Potential applications to gastrointestinal, intravascular and tumour perfusion imaging at subpicomolar concentrations are presented. These results demonstrate a new background-free imaging modality applicable to a range of inexpensive, readily available and biocompatible silicon particles.
Collapse
Affiliation(s)
- M C Cassidy
- School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, USA
| | | | | | | | | |
Collapse
|
227
|
Walker C, Gupta S, Raj V, Siddiqui S, Brightling CE. Imaging advances in asthma. ACTA ACUST UNITED AC 2013; 5:453-65. [PMID: 23484630 DOI: 10.1517/17530059.2011.609886] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
INTRODUCTION Asthma is a global burden, affecting 5% of the general adult population, with approximately 5 - 10% suffering from severe asthma. Severe asthma is a complex heterogeneous disease entity, with high morbidity and mortality. Recent years have seen the introduction of a vast array of new imaging technologies, which have provided the ability to comprehensively, non-invasively and functionally assess the lungs. These advances have resulted in a better understanding of the pathophysiology in severe asthma and have the unprecedented potential to unravel the structure-function relationship of severe asthma in the future. AREAS COVERED This review article chronologically describes the technological advances currently used and to be used in the future. The article covers pitfalls in imaging of the airways and lung parenchyma in asthma from chest x-rays, CT scans, MRI, confocal florescence endomicroscopy to computational fluid dynamics. EXPERT OPINION Novel qualitative and quantitative imaging techniques have enabled us to study the large airway architecture in detail, assess the small airway structure and perform functional or novel physiological evaluations. Despite spectacular advances in imaging techniques and the birth of new modalities, there is an urgent need for both proof-of-concept studies, large cross-sectional and longitudinal clinical trials in severe asthma to validate and clinically correlate imaging-derived measures. This will extend our current understanding of the pathophysiology of severe asthma, and unravel the structure-function relationship, with the potential to discover novel severe asthma phenotypes, predict mortality, morbidity and response to existing and novel pharmacological and non-pharmacological therapies.
Collapse
Affiliation(s)
- Carolina Walker
- University of Leicester , Institute for Lung Health, Department of Infection , Inflammation and Immunity, Leicester , UK
| | | | | | | | | |
Collapse
|
228
|
Svenningsen S, Kirby M, Starr D, Leary D, Wheatley A, Maksym GN, McCormack DG, Parraga G. Hyperpolarized (3) He and (129) Xe MRI: differences in asthma before bronchodilation. J Magn Reson Imaging 2013; 38:1521-30. [PMID: 23589465 DOI: 10.1002/jmri.24111] [Citation(s) in RCA: 120] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2012] [Accepted: 02/12/2013] [Indexed: 01/22/2023] Open
Abstract
PURPOSE To compare hyperpolarized helium-3 ((3) He) and xenon-129 ((129) Xe) MRI in asthmatics before and after salbutamol inhalation. MATERIALS AND METHODS Seven asthmatics provided written informed consent and underwent spirometry, plethysmography, and MRI before and after salbutamol inhalation. (3) He and (129) Xe ventilation defect percent (VDP) and ventilation coefficient of variation (COV) were measured. To characterize the airways spatially related to ventilation defects, wall area percent (WA%) and lumen area (LA) were evaluated for two subjects who had thoracic x-ray computed tomography (CT) acquired 1 year before MRI. RESULTS Before salbutamol inhalation, (129) Xe VDP (8 ± 5%) was significantly greater than (3) He VDP (6 ± 5%, P = 0.003). Post-salbutamol, there was a significant improvement in both (129) Xe (5 ± 4%, P < 0.0001) and (3) He (4 ± 3%, P = 0.001) VDP, and the improvement in (129) Xe VDP was significantly greater (P = 0.008). (129) Xe MRI COV (Pre: 0.309 ± 0.028, Post: 0.296 ± 0.036) was significantly greater than (3) He MRI COV (Pre: 0.282 ± 0.018, Post: 0.269 ± 0.024), pre- (P < 0.0001) and post-salbutamol (P < 0.0001) and the decrease in COV post-salbutamol was significant ((129) Xe, P = 0.002; (3) He, P < 0.0001). For a single asthmatic, a sub-segmental (129) Xe MRI ventilation defect that was visible only before salbutamol inhalation but not visible using (3) He MRI was spatially related to a remodeled fourth generation sub-segmental airway (WA% = 78%, LA = 2.9 mm(2) ). CONCLUSION In asthma, hyperpolarized (129) Xe MRI may help reveal ventilation abnormalities before bronchodilation that are not observed using hyperpolarized (3) He MRI.
Collapse
Affiliation(s)
- Sarah Svenningsen
- Imaging Research Laboratories, Robarts Research Institute, London, Canada; Department of Medical Biophysics, The University of Western Ontario, London, Canada
| | | | | | | | | | | | | | | |
Collapse
|
229
|
Abstract
Biomedical Engineering is a branch that unites engineering methods with biological and medical sciences in order to enhance the quality of our lives. It focuses on understanding intricate systems of living organisms, and on technology development, algorithms, methods, and advanced medical knowledge, while enhancing the conveyance and success of clinical medicine. With engineering principles, biomedical engineering improves the procedures and devices to overcome health care and medical problems by combining both biology and medicine with engineering principals. In the field of Biomedical Engineering, engineers usually need to have background knowledge from such different fields of engineering as electronics, mechanical, and chemical engineering. Specialties in this field like bioinstrumentation, biomechanics, biomaterials, medical imagining, clinical engineering, bioinformatics, telemedicine and rehabilitation engineering, which will be introduced in this chapter together with an overview of the field of biomedical engineering.
Collapse
|
230
|
Wild JM, Marshall H, Xu X, Norquay G, Parnell SR, Clemence M, Griffiths PD, Parra-Robles J. Simultaneous Imaging of Lung Structure and Function with Triple-Nuclear Hybrid MR Imaging. Radiology 2013; 267:251-5. [DOI: 10.1148/radiol.12121153] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
231
|
Lilburn DM, Pavlovskaya GE, Meersmann T. Perspectives of hyperpolarized noble gas MRI beyond 3He. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2013; 229:173-86. [PMID: 23290627 PMCID: PMC3611600 DOI: 10.1016/j.jmr.2012.11.014] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2012] [Revised: 11/12/2012] [Accepted: 11/15/2012] [Indexed: 05/29/2023]
Abstract
Nuclear Magnetic Resonance (NMR) studies with hyperpolarized (hp) noble gases are at an exciting interface between physics, chemistry, materials science and biomedical sciences. This paper intends to provide a brief overview and outlook of magnetic resonance imaging (MRI) with hp noble gases other than hp (3)He. A particular focus are the many intriguing experiments with (129)Xe, some of which have already matured to useful MRI protocols, while others display high potential for future MRI applications. Quite naturally for MRI applications the major usage so far has been for biomedical research but perspectives for engineering and materials science studies are also provided. In addition, the prospects for surface sensitive contrast with hp (83)Kr MRI is discussed.
Collapse
Affiliation(s)
| | | | - Thomas Meersmann
- University of Nottingham, School of Clinical Sciences, Sir Peter Mansfield Magnetic Resonance Centre, Nottingham NG7 2RD, United Kingdom
| |
Collapse
|
232
|
Palaniappan KK, Ramirez RM, Bajaj VS, Wemmer DE, Pines A, Francis MB. Molecular imaging of cancer cells using a bacteriophage-based 129Xe NMR biosensor. Angew Chem Int Ed Engl 2013; 52:4849-53. [PMID: 23554263 DOI: 10.1002/anie.201300170] [Citation(s) in RCA: 80] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2013] [Revised: 02/09/2013] [Indexed: 02/02/2023]
|
233
|
Palaniappan KK, Ramirez RM, Bajaj VS, Wemmer DE, Pines A, Francis MB. Molecular Imaging of Cancer Cells Using a Bacteriophage-Based129Xe NMR Biosensor. Angew Chem Int Ed Engl 2013. [DOI: 10.1002/ange.201300170] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
234
|
Kirby M, Svenningsen S, Kanhere N, Owrangi A, Wheatley A, Coxson HO, Santyr GE, Paterson NAM, McCormack DG, Parraga G. Pulmonary ventilation visualized using hyperpolarized helium-3 and xenon-129 magnetic resonance imaging: differences in COPD and relationship to emphysema. J Appl Physiol (1985) 2013; 114:707-15. [DOI: 10.1152/japplphysiol.01206.2012] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
In subjects with chronic obstructive pulmonary disease (COPD), hyperpolarized xenon-129 (129Xe) magnetic resonance imaging (MRI) reveals significantly greater ventilation defects than hyperpolarized helium-3 (3He) MRI. The physiological and/or morphological determinants of ventilation defects and the differences observed between hyperpolarized 3He and 129Xe MRI are not yet understood. Here we aimed to determine the structural basis for the differences in ventilation observed between 3He and 129Xe MRI in subjects with COPD using apparent diffusion coefficients (ADC) and computed tomography (CT). Ten COPD ex-smokers provided written, informed consent and underwent MRI, CT, spirometry, and plethysmography. 3He and 129Xe MRI ventilation volume was generated using semiautomated segmentation, and ADC maps were registered to generate ADC values for lung regions of interest ventilated by both gases (ADCHX) and by 3He gas only (ADCHO). CT wall area percentage and the lowest 15th percentile point of the CT lung density histogram (HU15%) were also evaluated. For lung regions accessed by 3He gas only, mean 3He ADCHO was significantly greater than for regions accessed by both gases (ADCHO = 0.503 ± 0.119 cm2/s, ADCHX = 0.470 ± 0.125 cm2/s, P < 0.0001). The difference between 3He and 129Xe ventilation volume was significantly correlated with CT HU15% ( r = −65, P = 0.04) and 3He ADCHO ( r = 0.70, P = 0.02), but not CT wall area percentage ( r = −0.34, P = 0.33). In conclusion, in this small study in COPD subjects, we observed significantly decreased 129Xe MRI ventilation compared with 3He MRI, and these regions of decreased 129Xe ventilation were spatially and significantly correlated with regions of increased pulmonary emphysema, but not airway wall thickness.
Collapse
Affiliation(s)
- Miranda Kirby
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Sarah Svenningsen
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Nikhil Kanhere
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
- Graduate Program in Biomedical Engineering, The University of Western Ontario, London, Ontario, Canada
| | - Amir Owrangi
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
- Graduate Program in Biomedical Engineering, The University of Western Ontario, London, Ontario, Canada
| | - Andrew Wheatley
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
| | - Harvey O. Coxson
- Department of Radiology & James Hogg Research Centre, Vancouver General Hospital, University of British Columbia, Vancouver, British Columbia, Canada; and
| | - Giles E. Santyr
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
| | - Nigel A. M. Paterson
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
- Division of Respirology, Department of Medicine, The University of Western Ontario, London, Ontario, Canada
| | - David G. McCormack
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
- Division of Respirology, Department of Medicine, The University of Western Ontario, London, Ontario, Canada
| | - Grace Parraga
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
- Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada
- Graduate Program in Biomedical Engineering, The University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
235
|
Qian C, Yu X, Chen DY, Dodd S, Bouraoud N, Pothayee N, Chen Y, Beeman S, Bennett K, Murphy-Boesch J, Koretsky A. Wireless amplified nuclear MR detector (WAND) for high-spatial-resolution MR imaging of internal organs: preclinical demonstration in a rodent model. Radiology 2013; 268:228-36. [PMID: 23392428 DOI: 10.1148/radiol.13121352] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To assess the feasibility of imaging deep-lying internal organs at high spatial resolution by imaging kidney glomeruli in a rodent model with use of a newly developed, wireless amplified nuclear magnetic resonance (MR) detector. MATERIALS AND METHODS This study was approved by the Animal Care and Use Committee at the National Institutes of Health/National Institute of Neurologic Disorder and Stroke. As a preclinical demonstration of this new detection technology, five different millimeter-scale wireless amplified nuclear MR detectors configured as double frequency resonators were chronically implanted on the medial surface of the kidney in five Sprague-Dawley rats for MR imaging at 11.7 T. Among these rats, two were administered gadopentetate dimeglumine to visualize renal tubules on T1-weighted gradient-refocused echo (GRE) images, two were administered cationized ferritin to visualize glomeruli on T2*-weighted GRE images, and the remaining rat was administered both gadopentetate dimeglumine and cationized ferritin to visualize the interleaved pattern of renal tubules and glomeruli. The image intensity in each pixel was compared with the local tissue signal intensity average to identify regions of hyper- or hypointensity. RESULTS T1-weighted images with 70-μm in-plane resolution and 200-μm section thickness were obtained within 3.2 minutes to image renal tubules, and T2*-weighted images of the same resolution were obtained within 5.8 minutes to image the glomeruli. Hyperintensity from gadopentetate dimeglumine enabled visualization of renal tubules, and hypointensity from cationic ferritin enabled visualization of the glomeruli. CONCLUSION High-spatial-resolution images have been obtained to observe kidney microstructures in vivo with a wireless amplified nuclear MR detector.
Collapse
Affiliation(s)
- Chunqi Qian
- Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Dr, Room 1D48, Bethesda, MD 20892, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
236
|
Kalber TL, Campbell-Washburn AE, Siow BM, Sage E, Price AN, Ordidge KL, Walker-Samuel S, Janes SM, Lythgoe MF. Primed infusion with delayed equilibrium of Gd.DTPA for enhanced imaging of small pulmonary metastases. PLoS One 2013; 8:e54903. [PMID: 23382996 PMCID: PMC3561448 DOI: 10.1371/journal.pone.0054903] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Accepted: 12/17/2012] [Indexed: 12/04/2022] Open
Abstract
Objectives To use primed infusions of the magnetic resonance imaging (MRI) contrast agent Gd.DTPA (Magnevist), to achieve an equilibrium between blood and tissue (eqMRI). This may increase tumor Gd concentrations as a novel cancer imaging methodology for the enhancement of small tumor nodules within the low signal-to-noise background of the lung. Methods A primed infusion with a delay before equilibrium (eqMRI) of the Gd(III) chelator Gd.DTPA, via the intraperitoneal route, was used to evaluate gadolinium tumor enhancement as a function of a bolus injection, which is applied routinely in the clinic, compared to gadolinium maintained at equilibrium. A double gated (respiration and cardiac) spin-echo sequence at 9.4T was used to evaluate whole lungs pre contrast and then at 15 (representative of bolus enhancement), 25 and 35 minutes (representative of eqMRI). This was carried out in two lung metastasis models representative of high and low tumor cell seeding. Lungs containing discrete tumor nodes where inflation fixed and taken for haematoxylin and eosin staining as well as CD34 staining for correlation to MRI. Results We demonstrate that sustained Gd enhancement, afforded by Gd equilibrium, increases the detection of pulmonary metastases compared to bolus enhancement and those tumors which enhance at equilibrium are sub-millimetre in size (<0.7 mm2) with a similar morphology to early bronchoalveolar cell carcinomas. Conclusion As Gd-chelates are routinely used in the clinic for detecting tumors by MRI, this methodology is readily transferable to the clinic and advances MRI as a methodology for the detection of small pulmonary tumors.
Collapse
Affiliation(s)
- Tammy L Kalber
- UCL Centre of Advanced Biomedical Imaging, Division of Medicine and Institute of Child Health, University College London, London, United Kingdom.
| | | | | | | | | | | | | | | | | |
Collapse
|
237
|
Introduction to 4D Motion Modeling and 4D Radiotherapy. 4D MODELING AND ESTIMATION OF RESPIRATORY MOTION FOR RADIATION THERAPY 2013. [DOI: 10.1007/978-3-642-36441-9_1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
238
|
Pravdivtsev AN, Yurkovskaya AV, Kaptein R, Miesel K, Vieth HM, Ivanov KL. Exploiting level anti-crossings for efficient and selective transfer of hyperpolarization in coupled nuclear spin systems. Phys Chem Chem Phys 2013; 15:14660-9. [DOI: 10.1039/c3cp52026a] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
239
|
Dregely I, Ruset IC, Wiggins G, Mareyam A, Mugler JP, Altes TA, Meyer C, Ruppert K, Wald LL, Hersman FW. 32-channel phased-array receive with asymmetric birdcage transmit coil for hyperpolarized xenon-129 lung imaging. Magn Reson Med 2012; 70:576-83. [PMID: 23132336 DOI: 10.1002/mrm.24482] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2011] [Revised: 08/06/2012] [Accepted: 08/11/2012] [Indexed: 11/09/2022]
Abstract
Hyperpolarized xenon-129 has the potential to become a noninvasive contrast agent for lung MRI. In addition to its utility for imaging of ventilated airspaces, the property of xenon to dissolve in lung tissue and blood upon inhalation provides the opportunity to study gas exchange. Implementations of imaging protocols for obtaining regional parameters that exploit the dissolved phase are limited by the available signal-to-noise ratio, excitation homogeneity, and length of acquisition times. To address these challenges, a 32-channel receive-array coil complemented by an asymmetric birdcage transmit coil tuned to the hyperpolarized xenon-129 resonance at 3 T was developed. First results of spin-density imaging in healthy subjects and subjects with obstructive lung disease demonstrated the improvements in image quality by high-resolution ventilation images with high signal-to-noise ratio. Parallel imaging performance of the phased-array coil was demonstrated by acceleration factors up to three in 2D acquisitions and up to six in 3D acquisitions. Transmit-field maps showed a regional variation of only 8% across the whole lung. The newly developed phased-array receive coil with the birdcage transmit coil will lead to an improvement in existing imaging protocols, but moreover enable the development of new, functional lung imaging protocols based on the improvements in excitation homogeneity, signal-to-noise ratio, and acquisition speed.
Collapse
Affiliation(s)
- Isabel Dregely
- Department of Physics, University of New Hampshire, Durham, New Hampshire, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
240
|
Kirby M, Kanhere N, Etemad-Rezai R, McCormack DG, Parraga G. Hyperpolarized helium-3 magnetic resonance imaging of chronic obstructive pulmonary disease exacerbation. J Magn Reson Imaging 2012; 37:1223-7. [DOI: 10.1002/jmri.23896] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Accepted: 09/17/2012] [Indexed: 11/06/2022] Open
|
241
|
Green RA, Adams RW, Duckett SB, Mewis RE, Williamson DC, Green GGR. The theory and practice of hyperpolarization in magnetic resonance using parahydrogen. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2012; 67:1-48. [PMID: 23101588 DOI: 10.1016/j.pnmrs.2012.03.001] [Citation(s) in RCA: 253] [Impact Index Per Article: 21.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2012] [Accepted: 03/05/2012] [Indexed: 05/03/2023]
Affiliation(s)
- Richard A Green
- Department of Chemistry, University of York, Heslington, York YO10 5DD, United Kingdom
| | | | | | | | | | | |
Collapse
|
242
|
Acosta RH, Blümler P, Münnemann K, Spiess HW. Mixture and dissolution of laser polarized noble gases: spectroscopic and imaging applications. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2012; 66:40-69. [PMID: 22980033 DOI: 10.1016/j.pnmrs.2012.03.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2011] [Accepted: 03/20/2012] [Indexed: 06/01/2023]
Affiliation(s)
- Rodolfo H Acosta
- FAMAF, Universidad Nacional de Córdoba, IFEG - CONICET, Córdoba, Argentina
| | | | | | | |
Collapse
|
243
|
Muradyan I, Butler JP, Dabaghyan M, Hrovat M, Dregely I, Ruset I, Topulos GP, Frederick E, Hatabu H, Hersman WF, Patz S. Single-breath xenon polarization transfer contrast (SB-XTC): implementation and initial results in healthy humans. J Magn Reson Imaging 2012; 37:457-70. [PMID: 23011916 DOI: 10.1002/jmri.23823] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2011] [Accepted: 08/14/2012] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To implement and characterize a single-breath xenon transfer contrast (SB-XTC) method to assess the fractional diffusive gas transport F in the lung: to study the dependence of F and its uniformity as a function of lung volume; to estimate local alveolar surface area per unit gas volume S(A)/V(Gas) from multiple diffusion time measurements of F; to evaluate the reproducibility of the measurements and the necessity of B(1) correction in cases of centric and sequential encoding. MATERIALS AND METHODS In SB-XTC three or four gradient echo images separated by inversion/saturation pulses were collected during a breath-hold in eight healthy volunteers, allowing the mapping of F (thus S(A)/V(Gas)) and correction for other contributions such as T(1) relaxation, RF depletion and B(1) inhomogeneity from inherently registered data. RESULTS Regional values of F and its distribution were obtained; both the mean value and heterogeneity of F increased with the decrease of lung volume. Higher values of F in the bases of the lungs in supine position were observed at lower volumes in all volunteers. Local S(A)/V(Gas) (with a mean ± standard deviation of S(A)/V(Gas) = 89 ± 30 cm(-1)) was estimated in vivo near functional residual capacity. Calibration of SB-XTC on phantoms highlighted the necessity for B(1) corrections when k-space is traversed sequentially; with centric ordering B(1) distribution correction is dispensable. CONCLUSION The SB-XTC technique is implemented and validated for in vivo measurements of local S(A)/V(Gas).
Collapse
Affiliation(s)
- Iga Muradyan
- Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
244
|
Witte C, Kunth M, Döpfert J, Rossella F, Schröder L. Hyperpolarized xenon for NMR and MRI applications. J Vis Exp 2012:4268. [PMID: 22986346 DOI: 10.3791/4268] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Nuclear magnetic resonance (NMR) spectroscopy and imaging (MRI) suffer from intrinsic low sensitivity because even strong external magnetic fields of ~10 T generate only a small detectable net-magnetization of the sample at room temperature (1). Hence, most NMR and MRI applications rely on the detection of molecules at relative high concentration (e.g., water for imaging of biological tissue) or require excessive acquisition times. This limits our ability to exploit the very useful molecular specificity of NMR signals for many biochemical and medical applications. However, novel approaches have emerged in the past few years: Manipulation of the detected spin species prior to detection inside the NMR/MRI magnet can dramatically increase the magnetization and therefore allows detection of molecules at much lower concentration (2). Here, we present a method for polarization of a xenon gas mixture (2-5% Xe, 10% N2, He balance) in a compact setup with a ca. 16000-fold signal enhancement. Modern line-narrowed diode lasers allow efficient polarization (7) and immediate use of gas mixture even if the noble gas is not separated from the other components. The SEOP apparatus is explained and determination of the achieved spin polarization is demonstrated for performance control of the method. The hyperpolarized gas can be used for void space imaging, including gas flow imaging or diffusion studies at the interfaces with other materials (8,9). Moreover, the Xe NMR signal is extremely sensitive to its molecular environment (6). This enables the option to use it as an NMR/MRI contrast agent when dissolved in aqueous solution with functionalized molecular hosts that temporarily trap the gas (10,11). Direct detection and high-sensitivity indirect detection of such constructs is demonstrated in both spectroscopic and imaging mode.
Collapse
Affiliation(s)
- Christopher Witte
- ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie
| | | | | | | | | |
Collapse
|
245
|
Bauman G, Eichinger M. Ventilation and perfusion magnetic resonance imaging of the lung. Pol J Radiol 2012; 77:37-46. [PMID: 22802864 PMCID: PMC3389953 DOI: 10.12659/pjr.882579] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2011] [Accepted: 01/19/2012] [Indexed: 02/02/2023] Open
Abstract
A close interaction between the respiratory pump, pulmonary parenchyma and blood circulation is essential for a normal lung function. Many pulmonary diseases present, especially in their initial phase, a variable regional impairment of ventilation and perfusion. In the last decades various techniques have been established to measure the lung function. Besides the global pulmonary function tests (PFTs) imaging techniques gained increasing importance to detect local variations in lung function, especially for ventilation and perfusion assessment. Imaging modalities allow for a deeper regional insight into pathophysiological processes and enable improved planning of invasive procedures. In contrast to computed tomography (CT) and the nuclear medicine techniques, magnetic resonance imaging (MRI), as a radiation free imaging modality gained increasing importance since the early 1990 for the assessment of pulmonary function. The major inherent problems of lung tissue, namely the low proton density and the pulmonary and cardiac motion, were overcome in the last years by a constant progress in MR technology. Some MR techniques are still under development, a process which is driven by scientific questions regarding the physiology and pathophysiology of pulmonary diseases, as well as by the need for fast and robust clinically applicable imaging techniques as safe therapy monitoring tools. MRI can be considered a promising ionizing-free alternative to techniques like CT or nuclear medicine techniques for the evaluation of lung function. The goal of this article is to provide an overview on selected MRI techniques for the assessment of pulmonary ventilation and perfusion.
Collapse
Affiliation(s)
- Grzegorz Bauman
- German Cancer Research Center, Department of Medical Physics in Radiology, Heidelberg, Germany
| | | |
Collapse
|
246
|
Kircher MF, Willmann JK. Molecular body imaging: MR imaging, CT, and US. part I. principles. Radiology 2012; 263:633-43. [PMID: 22623690 DOI: 10.1148/radiol.12102394] [Citation(s) in RCA: 133] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Molecular imaging, generally defined as noninvasive imaging of cellular and subcellular events, has gained tremendous depth and breadth as a research and clinical discipline in recent years. The coalescence of major advances in engineering, molecular biology, chemistry, immunology, and genetics has fueled multi- and interdisciplinary innovations with the goal of driving clinical noninvasive imaging strategies that will ultimately allow disease identification, risk stratification, and monitoring of therapy effects with unparalleled sensitivity and specificity. Techniques that allow imaging of molecular and cellular events facilitate and go hand in hand with the development of molecular therapies, offering promise for successfully combining imaging with therapy. While traditionally nuclear medicine imaging techniques, in particular positron emission tomography (PET), PET combined with computed tomography (CT), and single photon emission computed tomography, have been the molecular imaging methods most familiar to clinicians, great advances have recently been made in developing imaging techniques that utilize magnetic resonance (MR), optical, CT, and ultrasonographic (US) imaging. In the first part of this review series, we present an overview of the principles of MR imaging-, CT-, and US-based molecular imaging strategies.
Collapse
Affiliation(s)
- Moritz F Kircher
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY, USA
| | | |
Collapse
|
247
|
Iguchi S, Imai H, Hori Y, Nakajima J, Kimura A, Fujiwara H. Direct imaging of hyperpolarized 129Xe alveolar gas uptake in a mouse model of emphysema. Magn Reson Med 2012; 70:207-15. [PMID: 22887860 DOI: 10.1002/mrm.24452] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Revised: 06/27/2012] [Accepted: 07/11/2012] [Indexed: 01/07/2023]
Abstract
MRI of hyperpolarized (129)Xe dissolved in pulmonary tissues, and blood has the potential to offer a new tool for regional evaluation of pulmonary gas exchange and perfusion; however, the extremely short T2* and low magnetization density make it difficult to acquire the image. In this study, an ultrashort echo-time sequence was introduced, and its feasibility to quantitatively assess emphysema-like pulmonary tissue destruction by a combination of dissolved- and gas-phase (129)Xe lung MRI was investigated. The ultrashort echo-time has made it possible to acquire dissolved (129)Xe images with reasonably high spatial resolution of 0.625 × 0.625 mm(2) and to obtain T2* of 0.67 ± 0.30 ms in a spontaneously breathing mouse at 9.4 T. The regional dynamic alveolar gas uptake as well as subsequent transport by pulmonary blood flow was also visualized. The ratio of (129)Xe magnetization that diffused into the septa relative to the gas-phase magnetization F was regionally evaluated. The mean F value of elastase-treated mice was 2.28 ± 0.46%, which was significantly reduced from that of control mice 3.41 ± 0.48% (P = 0.0052). This reflects the reduced uptake efficiency due to alveolar tissue destruction and is correlated with the histologically derived alveolar surface-to-volume ratio.
Collapse
Affiliation(s)
- Satoshi Iguchi
- Department of Medical Physics and Engineering, Division of Health Sciences, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | | | | | | | | | | |
Collapse
|
248
|
Washko GR, Parraga G, Coxson HO. Quantitative pulmonary imaging using computed tomography and magnetic resonance imaging. Respirology 2012; 17:432-44. [PMID: 22142490 DOI: 10.1111/j.1440-1843.2011.02117.x] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Measurements of lung function, including spirometry and body plethesmography, are easy to perform and are the current clinical standard for assessing disease severity. However, these lung functional techniques do not adequately explain the observed variability in clinical manifestations of disease and offer little insight into the relationship of lung structure and function. Lung imaging and the image-based assessment of lung disease has matured to the extent that it is common for clinical, epidemiologic and genetic investigation to have a component dedicated to image analysis. There are several exciting imaging modalities currently being used for the non-invasive study of lung anatomy and function. In this review, we will focus on two of them; X-ray computed tomography and magnetic resonance imaging. Following a brief introduction of each method, we detail some of the most recent work being done to characterize smoking-related lung disease and the clinical applications of such knowledge.
Collapse
Affiliation(s)
- George R Washko
- Department of Medicine, Division of Pulmonary and Critical Care Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA
| | | | | |
Collapse
|
249
|
Massot P, Parzy E, Pourtau L, Mellet P, Madelin G, Marque S, Franconi JM, Thiaudiere E. In vivo high-resolution 3D overhauser-enhanced MRI in mice at 0.2 T. CONTRAST MEDIA & MOLECULAR IMAGING 2012; 7:45-50. [PMID: 22344879 DOI: 10.1002/cmmi.464] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Overhauser-enhanced MRI (OMRI) offers the potentiality of detecting low-concentrated species generated by specific biological processes. However molecular imaging applications of OMRI need significant improvement in spatial localization. Here it is shown that 3D-OMRI of a free radical injected in tumor-bearing mice can be performed at high anatomical resolution at a constant field. A 30 mm cavity operating at 5.43 GHz was inserted in a C-shaped magnet for proton MRI at 0.194 T. Nude mice with or without brain-implanted C6 rat glioma were positioned in the cavity and injected with TOPCA (1-oxyl-2,2,5,5-tetramethyl-2,5-dihydro-1H-pyrrole-3-carboxylic acid). OMRI was performed in 3D within several minutes in the brain region without high overheating of the animals. Voxel size was 0.5 × 0.5 × 1 mm³ , providing good delineation of brain regions. Signal amplifications ranged from 2 in tumors to 10 in vessels several minutes after TOPCA injection. Time-course of signal enhancement could be measured by 2D OMRI at 15 s time intervals in a localized thin slice. The method opens the way for molecular imaging of biological activities able to generate OMRI-visible free radicals.
Collapse
|
250
|
Simon BA, Kaczka DW, Bankier AA, Parraga G. What can computed tomography and magnetic resonance imaging tell us about ventilation? J Appl Physiol (1985) 2012; 113:647-57. [PMID: 22653989 DOI: 10.1152/japplphysiol.00353.2012] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
This review provides a summary of pulmonary functional imaging approaches for determining pulmonary ventilation, with a specific focus on multi-detector x-ray computed tomography and magnetic resonance imaging (MRI). We provide the important functional definitions of pulmonary ventilation typically used in medicine and physiology and discuss the fact that some of the imaging literature describes gas distribution abnormalities in pulmonary disease that may or may not be related to the physiological definition or clinical interpretation of ventilation. We also review the current state-of-the-field in terms of the key physiological questions yet unanswered related to ventilation and gas distribution in lung disease. Current and emerging imaging research methods are described, including their strengths and the challenges that remain to translate these methods to more wide-spread research and clinical use. We also examine how computed tomography and MRI might be used in the future to gain more insight into gas distribution and ventilation abnormalities in pulmonary disease.
Collapse
Affiliation(s)
- Brett A Simon
- Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA
| | | | | | | |
Collapse
|