301
|
Kanayasu-Toyoda T, Morita I, Murota S. Arachidonic acid pretreatment enhances smooth muscle cell migration via increased Ca2+ influx. Prostaglandins Leukot Essent Fatty Acids 1998; 58:25-31. [PMID: 9482163 DOI: 10.1016/s0952-3278(98)90126-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
It is well known that vascular smooth muscle cell (SMC) migration is an initial step in atheromatous plaque formation. In the present study, we investigated the effects of arachidonic acid (AA, 20:4 n-6) on bovine carotid artery SMC migration using the modified Boyden chamber technique. SMCs pretreated with 2.5 microg/ml of AA for 2 days, showed an enhanced migration response to fetal bovine serum. AA pretreatment (0.5-5.0 microg/ml) increased fetal bovine serum-induced SMC migration dose-dependently, and maximum stimulation was observed at a concentration of 2.5 microg/ml. However, AA pretreatment did not enhance fetal bovine serum-induced endothelial cell migration. Using lipid analysis, we found that AA was substantially incorporated into cellular phospholipids. When SMC migration was induced by platelet derived growth factor (PDGF)-BB, instead of serum, the stimulative effect of AA pretreatment was retained. SMCs pretreated with AA showed greater mobilization of intracellular Ca2+ in response to PDGF-BB than SMCs without AA pretreatment (controls). Nifedipine, a Ca2+ channel blocker, and glycoletherdiamine-tetraacetic acid (EGTA) had no effect on PDGF-induced migration of controls but both drugs reduced the enhanced PDGE-induced migration of AA-pretreated SMCs to the control level. Baicalein, an inhibitor of 12-lipoxygenase, reduced PDGF-BB-induced migration of both control and AA pretreated SMCs, however the AA-pretreated cells still showed enhanced migration compared to control cells. These findings suggest that AA accelerates SMC migration in the thickening of the intima during atheroma formation, via stimulation of extracellular Ca2+ influx.
Collapse
Affiliation(s)
- T Kanayasu-Toyoda
- Division of Biological Chemistry and Biologicals, National Institute of Health Sciences, Tokyo, Japan
| | | | | |
Collapse
|
302
|
Baker WF. Thrombosis and Hemostasis in Cardiology: Review of Pathophysiology and Clinical Practice (Part I). Clin Appl Thromb Hemost 1998. [DOI: 10.1177/107602969800400107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
The adverse consequences of thrombosis are per haps nowhere more evident than in clinical cardiology. Throm bosis and hemostasis are primary issues in the management of patients with atrial fibrillation, prosthetic heart valves, severe left ventricular dysfunction, and coronary artery disease. Clini cal trials have defined a crucial role for anticoagulation with warfarin in patients with atrial fibrillation to reduce the inci dence of stroke. Anticoagulation with warfarin and aspirin in combination offers significant protection from systemic emboli in patients with mechanical prosthetic valves, without a sub stantial increased risk of hemorrhage. The risk of systemic emboli may also be reduced by anticoagulation in patients with severe left ventricular dysfunction. Disturbance of the normal balance of hemostasis is a major factor in the pathophysiology of coronary artery disease. Antiplatelet therapy, antithrombin agents, anticoagulants, and fibrinolytic agents have been used to prevent and treat acute coronary thrombosis and to prevent reocclusion following thrombolysis and interventional therapy. Guidelines are presented for antithrombotic therapy in the prac tice of clinical cardiology.
Collapse
Affiliation(s)
- William F. Baker
- Central California Heart Institute, Bakersfield, California and Department of Medicine, Center for Health Sciences, University of California at Los Angeles, Los Angeles, California, U.S.A
| |
Collapse
|
303
|
Sugimura T, Yokoi H, Sato N, Akagi T, Kimura T, Iemura M, Nobuyoshi M, Kato H. Interventional treatment for children with severe coronary artery stenosis with calcification after long-term Kawasaki disease. Circulation 1997; 96:3928-33. [PMID: 9403617 DOI: 10.1161/01.cir.96.11.3928] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND About 4% of children with Kawasaki disease (KD) eventually develop ischemic heart disease, which is often associated with calcified stenosis. We assessed the utility of the percutaneous transluminal coronary rotational ablation (PTCRA) in children with coronary artery stenosis after KD. METHODS AND RESULTS Four children (three boys and one girl; age, 12 to 13 years) with coronary artery stenosis underwent percutaneous transluminal coronary angioplasty (PTCA) and PTCRA 11.8+/-0.9 years after the onset of KD. Morphology of the coronary artery wall was evaluated by intravascular ultrasound imaging. In one patient, the targeted lesion for intervention was in the left anterior descending artery (90% stenosis); in the other three patients, it was in the middle of the right coronary artery (75% to 90% stenosis). PTCA failed in three patients because of severe stenosis with calcification. However, PTCRA proved effective, with stenosis rates reduced from 90% to 25%. Follow-up coronary angiography performed 4 months after the procedure demonstrated no restenosis, but mild aneurysms occurred in two patients. CONCLUSIONS This study suggests that PTCRA is useful for revascularizing coronary arteries with severe stenosis and calcification as long-term sequelae of KD. Intravascular ultrasound imaging is useful in assessing the coronary artery wall pathology and in selecting the best treatment intervention.
Collapse
Affiliation(s)
- T Sugimura
- Department of Pediatrics, Kurume University School of Medicine, Kokura Memorial Hospital, Japan
| | | | | | | | | | | | | | | |
Collapse
|
304
|
Indolfi C, Avvedimento EV, Rapacciuolo A, Esposito G, Di Lorenzo E, Leccia A, Pisani A, Chieffo A, Coppola A, Chiariello M. In vivo gene transfer: prevention of neointima formation by inhibition of mitogen-activated protein kinase kinase. Basic Res Cardiol 1997; 92:378-84. [PMID: 9464861 DOI: 10.1007/bf00796211] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND The mitogen-activated protein kinase kinase (MAPKK) is a protein downstream ras which is rapidly activated in cells stimulated with various extracellular signals. These proteins are believed to play a pivotal role in integrating and transmitting transmembrane signals required for cell growth. METHODS AND RESULTS To study the effect of inhibition of MAPKK on smooth muscle cell (SMC) proliferation in vivo after vascular injury, we performed experimental balloon angioplasty using the standard Clowes technique in male Wistar rats 14-weeks old. The animals did not receive any treatment after vascular injury (N = 6) or were randomly assigned to receive, after balloon injury, a 30% (w/v) pluronic gel solution applied to the injured carotid artery, containing respectively: 1) no plasmid DNA (n = 10); 2) RSV-lacZ (encoding the beta-galactosidase gene) as control gene without effects on SMC proliferation (n = 10); 3) Tg-CAT (encoding cloramphenicol acetyl-transferase gene under the control of thyreoglobulin promoter) as an additional control gene without effects on SMC proliferation (n = 7): 4) a negative mutant of Mitogen-Activated Protein Kinase Kinase (MAPKK-) (n = 13). Fourteen days after vascular injury, carotid arteries were removed and cross sections were cut and stained with hematoxylin/eosin. Morphometric analysis demonstrated, in the MAPKK- treated rats, a significant reduction of both neointima (0.096+/-.018 mm2 vs. 0.184+/-0.019 mm2, p < 0.01) and neointima/media ratio (0.603+/-0.103 vs. 1.471+/-0.161, p < 0.01) compared to control DNA. CONCLUSIONS The inhibition of MAPKK, by a dominant inhibitor mutant gene, prevents the SMC proliferation after vascular injury in vivo.
Collapse
Affiliation(s)
- C Indolfi
- Division of Cardiology, Federico II University, Napoli, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
305
|
Baldwin AL, Wilson LM, Gradus-Pizlo I, Wilensky R, March K. Effect of atherosclerosis on transmural convection an arterial ultrastructure. Implications for local intravascular drug delivery. Arterioscler Thromb Vasc Biol 1997; 17:3365-75. [PMID: 9437181 DOI: 10.1161/01.atv.17.12.3365] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Local infusion of agents through perforated catheters may reduce neointimal formation following vascular angioplasty. Such treatment will succeed only if the drug is retained within the arterial intima long enough to promote repair. Drugs will be dispersed throughout the wall predominantly by transmural convection instead of diffusion if the Peclet number, Pe = J (1-delta f)/P, is greater than unity, where J is the transmural fluid flow per unit surface area and delta(f) and P are the reflection and permeability coefficients to the drug, respectively. Although the targets of local drug delivery will be atherosclerotic vessels, little is known about the transport properties of these vessels. Accordingly, we evaluated the effects of hypercholesterolemia and atherosclerosis on J per unit pressure (hydraulic conductance, Lp) and on ultrastructure in femoral arteries. Measurements were made at 30, 60, and 90 mm Hg in anesthetized New Zealand white rabbits fed a normal diet (n = 6) and after 3 weeks of lipid feeding (n = 19). Atherosclerosis was induced in six lipid-fed animals by air desiccation of a femoral artery. Hydraulic conductance was significantly greater in vessels from hypercholesterolemic than from normal animals and decreased with pressure only in hypercholesterolemic arteries. Atherosclerosis did not augment hydraulic conductance compared with hypercholesterolemia alone. Electron microscopic examination demonstrated damaged endothelium in hypercholesterolemic arteries and both altered endothelium and less tightly packed medial tissue, compared with controls, in atherosclerotic vessels, at least at lower pressures. Peclet numbers for macromolecules exceeded unity for all three groups of arteries and reached 0.3 to 0.4 for molecules as small as heparin. Thus, convection plays a dominant role in the distribution of macromolecular agents following local delivery and may result in their rapid transport to the adventitia in the femoral artery.
Collapse
Affiliation(s)
- A L Baldwin
- Department of Physiology, College of Medicine, University of Arizona, Tucson 85724, USA.
| | | | | | | | | |
Collapse
|
306
|
Mondy JS, Williams JK, Adams MR, Dean RH, Geary RL. Structural determinants of lumen narrowing after angioplasty in atherosclerotic nonhuman primates. J Vasc Surg 1997; 26:875-83. [PMID: 9372828 DOI: 10.1016/s0741-5214(97)70103-4] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
PURPOSE The relationship between lumen narrowing, intimal hyperplasia, and wall remodeling after angioplasty was explored in a nonhuman primate model of atherosclerosis. METHODS Cynomolgus monkeys (n = 37) used in long-term atherosclerosis studies underwent left iliac artery balloon injury. The uninjured right iliac artery served as a reference segment for intraanimal comparisons. One month later iliac arteries were fixed by perfusion (100 mm Hg) and removed for cross-sectional analysis to determine mean values for lumen area (LA), intimal area (IA), internal elastic lamina area (IELA), plaque burden (IA/IELA), and depth of wall injury. Values for each balloon-injured iliac artery were normalized to the contralateral uninjured iliac artery (percent of control), and linear regression analysis was performed comparing LA with IA, with IELA, and with depth of injury. Comparisons were also made between those arteries that remained dilated 1 month after balloon injury (LA > or = 140%; n = 13) and those that renarrowed (LA < or = 100%; n = 14). RESULTS For all 37 animals, LA 1 month after balloon injury correlated well with IELA (r = 0.72; p < 0.001) but not with IA (r = 0.10; p = 0.54), suggesting that changes in artery size rather than neointimal mass determined lumen caliber. When comparing arteries that remained dilated (n = 13) with those that renarrowed (n = 14), there were no differences in depth of wall injury (injury depth: 0, no injury; 1, intima; 2, IEL; 3, media; 4, EEL; 2.1 +/- 0.3 vs 1.6 +/- 0.3; p = 0.12), neointimal accumulation (IA, 507% +/- 118% vs. 421% +/- 81% of control; p = 0.55), or plaque burden (IA/IELA, 0.39 +/- 0.04 vs 0.37 +/- 0.06; p = 0.71), respectively. However, wall size defined as IELA was significantly smaller in arteries that renarrowed than in those that remained dilated (IELA, 115% +/- 14% vs 230% +/- 19% of control; p < 0.001). CONCLUSIONS Restenosis after angioplasty has been attributed to intimal hyperplasia, equating loss of lumen caliber with neointimal mass. The data presented herein suggest that lumen narrowing after arterial wall injury may have little to do with intimal mass per se, but rather that a change in wall caliber or wall narrowing is the cause of restenosis.
Collapse
Affiliation(s)
- J S Mondy
- Department of Surgery, Bowman Gray School of Medicine, Wake Forest University, Winston-Salem, NC, USA
| | | | | | | | | |
Collapse
|
307
|
Imanishi T, Arita M, Tomobuchi Y, Hamada M, Hano T, Nishio I. Effects of locally administered argatroban on restenosis after balloon angioplasty: experimental and clinical study. Clin Exp Pharmacol Physiol 1997; 24:800-6. [PMID: 9363360 DOI: 10.1111/j.1440-1681.1997.tb02694.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
1. This study was undertaken to evaluate the preventive effects of locally administered argatroban, a competitive inhibitor of thrombin-induced platelet activation, on restenosis after balloon angioplasty. 2. A hydrogel-coated balloon catheter was immersed three times in argatroban/saline solution (1 mg/mL) for 60 s, inflated to a pressure of 606 kPa and left in the rabbit common carotid artery for 1 min. The same procedure was performed, without drug, as a control. The pharmacokinetics of delivered argatroban in the arterial wall were assessed using [14C]-argatroban. Platelet deposition 2 h after balloon injury was quantified by fluorescence studies using antiplatelet antibody. Vascular smooth muscle cell (VSMC) proliferation 3 days after balloon injury was assessed by immunohistochemical staining for proliferative cell nuclear antigen (PCNA). In a clinical study, we divided 50 elective patients into two groups: argatroban and control. 3. In the experimental study, the mean quantities of argatroban at 0, 2 and 6 h after deflation were 24.63, 0.49 and 0.11 nmol/g wet weight of artery, respectively. Argatroban was undetected 24 h after deflation. Two hours after deflation, argatroban-treated arteries showed less platelet adhesion than saline-treated controls. The mean number of PCNA-positive cells was 16.9 and 43.8% in the argatroban and control groups, respectively (P < 0.01). In the clinical study, the mean late gain loss was 8.2 and 27.3% in the argatroban and control groups, respectively (P < 0.05). The mean late restenosis rate was 11.1 and 41.4% in the argatroban and control groups, respectively (P < 0.05). 4. These data suggest that blood coagulation plays a significant role in VSMC proliferation after balloon injury and that locally administered argatroban using hydrogel-coated balloon catheter may prevent post-percutaneous transluminal coronary angioplasty restenosis.
Collapse
Affiliation(s)
- T Imanishi
- Department of Medicine, Wakayama Medical College, Japan
| | | | | | | | | | | |
Collapse
|
308
|
Ueno H, Li JJ, Masuda S, Qi Z, Yamamoto H, Takeshita A. Adenovirus-mediated expression of the secreted form of basic fibroblast growth factor (FGF-2) induces cellular proliferation and angiogenesis in vivo. Arterioscler Thromb Vasc Biol 1997; 17:2453-60. [PMID: 9409215 DOI: 10.1161/01.atv.17.11.2453] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Blood supply through collateral arteries is of critical importance in occlusive arterial diseases such as coronary atherosclerosis. Induction of angiogenic growth factor within either the narrowing arteries or jeopardized myocardium may promote angiogenesis in vivo, leading to salvage of ischemic myocardium. We constructed a replication-defective adenovirus (AdCAsFGF-2) coding for human basic fibroblast growth factor (FGF)-2 that is modified, so that its secretion will be facilitated, by tagging a signal sequence derived from FGF-4. A large quantity of FGF-2 was detected in both the cell lysate and culture medium of COS cells infected with AdCAsFGF-2, indicating that FGF-2 was secreted at least partly from the infected cells. The conditioned medium from the infected COS cells stimulated DNA synthesis in and induced cellular proliferation of arterial smooth muscle cells. These effects were eliminated by adenovirus-mediated overexpression of a dominant-negative truncated FGF-receptor type 1. Implantation of a gel of basement membrane proteins containing fibroblasts infected with AdCAsFGF-2 into the ventral subcutaneous space of mice induced extensive cellular proliferation and the formation of functional arterioles. Cells surrounding the vessels were positively immunostained with antibodies recognizing either smooth muscle-specific alpha-actin or factor VIII antigen as a marker for endothelium. These results suggest that AdCAsFGF-2 may be useful for delivering functional FGF-2 into tissues and may lead to therapeutic angiogenesis in vivo.
Collapse
MESH Headings
- Actins/analysis
- Adenoviridae/genetics
- Animals
- Arterioles
- Biomarkers
- COS Cells
- Cattle
- Cell Division/drug effects
- Culture Media, Conditioned/pharmacology
- DNA Replication/drug effects
- Defective Viruses/genetics
- Endothelium, Vascular/cytology
- Factor VIII/analysis
- Fibroblast Growth Factor 2/genetics
- Fibroblast Growth Factor 2/metabolism
- Fibroblast Growth Factor 2/physiology
- Fibroblast Growth Factor 2/therapeutic use
- Fibroblast Growth Factor 4
- Fibroblast Growth Factors/genetics
- Fibroblasts/transplantation
- Genetic Therapy
- Genetic Vectors/genetics
- Humans
- Injections, Subcutaneous
- Mice
- Mice, Inbred BALB C
- Muscle, Smooth, Vascular/cytology
- Muscle, Smooth, Vascular/drug effects
- Myocardial Infarction/therapy
- Neovascularization, Pathologic/physiopathology
- Protein Sorting Signals/genetics
- Proto-Oncogene Proteins/genetics
- Receptors, Fibroblast Growth Factor/deficiency
- Receptors, Fibroblast Growth Factor/drug effects
- Receptors, Fibroblast Growth Factor/genetics
- Recombinant Fusion Proteins/physiology
Collapse
Affiliation(s)
- H Ueno
- Department of Cardiology, Kyushu University School of Medicine, Fukuoka, Japan.
| | | | | | | | | | | |
Collapse
|
309
|
Unverdorben M, Groll M, Glaeser P, Osypka P, Osypka T, Kunkel B, Vallbracht C. Preliminary results achieved by a computer-assisted system for controlled balloon dilatation of coronary and peripheral arteries. COMPUTERS AND BIOMEDICAL RESEARCH, AN INTERNATIONAL JOURNAL 1997; 30:403-13. [PMID: 9457440 DOI: 10.1006/cbmr.1997.1457] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
In percutaneous balloon angioplasty the extent of trauma to the vessel as determined by slope of balloon inflation, peak pressure, and inflation time is crucial to the success of the intervention. These parameters are still not standardized and hence open to the operator. To elucidate this problem, a computer-assisted PTCA system (CAPS) was developed. CAPS is composed of a motor driven unit, a central processing and power unit, and a notebook. A syringe is clamped onto the motor unit and connected to a pressure gauge. CAPS may be linked to all types of balloon catheters. The notebook allows for preselection of peak pressure, slope of pressure increase, and inflation time. During balloon inflation, adjustments are made in a closed-loop system. On a screen, the inflation process is supervised in digital numbers and analogous curves. After the procedure, patient data and inflation curves may be recalled for analysis. In conclusion, CAPS by controlled inflation theoretically may reduce the mechanical trauma to the arteries. Further refinements should aim at gaining information on the lesions' characteristics and on the dilatation process itself.
Collapse
Affiliation(s)
- M Unverdorben
- Center for Cardiovascular Diseases, Rotenburg a.d. Fulda, Grenzach-Wyhlen, Germany
| | | | | | | | | | | | | |
Collapse
|
310
|
Kosuga K, Tamai H, Ueda K, Hsu YS, Ono S, Tanaka S, Doi T, Myou-U W, Motohara S, Uehata H. Effectiveness of tranilast on restenosis after directional coronary atherectomy. Am Heart J 1997; 134:712-8. [PMID: 9351739 DOI: 10.1016/s0002-8703(97)70055-3] [Citation(s) in RCA: 49] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Tranilast is an antiallergic drug used widely in Japan that also inhibits the migration and proliferation of vascular smooth muscle cells. This pilot study was undertaken to determine the effectiveness of tranilast on restenosis after successful directional coronary atherectomy. After the procedure, 40 patients (56 lesions, tranilast group) were treated with oral tranilast for 3 months, and 152 patients (188 lesions, control group) did not receive tranilast. Angiographic and clinical variables were compared between the two groups. The minimal lumen diameter was significantly larger in the tranilast group than in the control group at both 3-month (2.08 vs 1.75 mm, p = 0.004) and 6-month follow-up (2.04 vs 1.70 mm, p = 0.003). The diameter stenosis in the tranilast group was smaller than that in the control group both 3 months (28% vs 40%, p = 0.0007) and 6 months (30% vs 43%, p = 0.0001) after the procedure, with a lower restenosis rate (percent diameter stenosis > or =50) in the tranilast group at 3 months (11 % vs 26%, p = 0.03). The number of clinical events over the 12-month period after the procedure was significantly reduced by tranilast administration (p = 0.013). These findings suggest that the oral administration of tranilast strongly prevents restenosis after directional coronary atherectomy.
Collapse
Affiliation(s)
- K Kosuga
- Department of Cardiology, Shiga Medical Center for Adult Diseases, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
311
|
Yokoi H, Daida H, Kuwabara Y, Nishikawa H, Takatsu F, Tomihara H, Nakata Y, Kutsumi Y, Ohshima S, Nishiyama S, Seki A, Kato K, Nishimura S, Kanoh T, Yamaguchi H. Effectiveness of an antioxidant in preventing restenosis after percutaneous transluminal coronary angioplasty: the Probucol Angioplasty Restenosis Trial. J Am Coll Cardiol 1997; 30:855-62. [PMID: 9316509 DOI: 10.1016/s0735-1097(97)00270-2] [Citation(s) in RCA: 129] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVES The Probucol Angioplasty Restenosis Trial was a prospective, randomized, controlled study that investigated the effectiveness of probucol therapy in reducing the rate of restenosis after percutaneous transluminal coronary angioplasty (PTCA). BACKGROUND Antioxidants have an inhibitory effect on smooth muscle cell growth in experiments in vitro and in vivo, which suggests a possible pharmacologic effect on restenosis after PTCA. METHODS One hundred one patients were randomly assigned to receive 1,000 mg/day of probucol or control (no lipid-lowering) therapy 4 weeks before PTCA. After 4 weeks of premedication, both groups underwent PTCA. Probucol was continued until follow-up angiography 24 weeks after PTCA. Angiographic results were analyzed at a core laboratory by quantitative coronary angiography. RESULTS Dilation was successful in 46 of 50 patients in the probucol group and 45 of 51 in the control group. At follow-up angiography 24 weeks after angioplasty, angiographic restenosis occurred in 9 (23%) of 40 patients in the probucol group and 22 (58%) of 38 in the control group (p = 0.001). Minimal lumen diameter was 1.49 +/- 0.75 mm (mean +/- SD) in the probucol group and 1.13 +/- 0.65 mm in the control group (p = 0.02). Percent diameter stenosis at follow-up angiography in the probucol group was significantly lower than that in the control group (43.9% vs. 56.4%, p = 0.009). The late loss was 0.37 +/- 0.69 mm in the probucol group and 0.60 +/- 0.62 mm in the control group (p = 0.13). The loss/gain ratio was 0.32 +/- 0.74 in the probucol group and 0.56 +/- 0.81 in the control group (p = 0.059). Net gain was greater in the probucol group than in the control group (0.77 +/- 0.70 vs. 0.48 +/- 0.59 mm, p = 0.053). CONCLUSIONS Probucol administered beginning 4 weeks before PTCA appears to reduce restenosis rates.
Collapse
Affiliation(s)
- H Yokoi
- Department of Cardiology, Juntendo University, Tokyo, Japan
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
312
|
Ponde CK, Watson PS, Aroney CN, Dooris M, Garrahy PJ, Cameron J, McEniery PT, Bett JH. Multiple stent implantation in single coronary arteries: acute results and six-month angiographic follow-up. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1997; 42:158-65. [PMID: 9328700 DOI: 10.1002/(sici)1097-0304(199710)42:2<158::aid-ccd14>3.0.co;2-k] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A total of 147 stents were implanted (in overlapping manner in 76% of vessels) in a single coronary artery in 59 patients (60 vessels, 97 lesions, 2.45 stents/vessel) over a period of 18 mo using high pressure stent deployment without ultrasound guidance. The indications for stenting were suboptimal percutaneous transluminal coronary angioplasty (PTCA) result (45%), primary prevention of restenosis (44%), acute closure (10%), and restenosis after plain balloon angioplasty (1%). One patient required emergency coronary artery bypass grafting (CABG) (extensive dissection), and one required early intervention with plain balloon angioplasty and intracoronary urokinase for stent thrombosis. There were no deaths. Thirteen patients had recurrence of angina within 6 mo and angiograms were performed in all. These showed intrastent restenosis in nine (all had successful repeat plain balloon angioplasty), development of new disease in other vessels along with restenosis close to the stent in the target vessel in one (underwent elective CABG) and normal angiograms with widely patent stents in three. Forty-five patients (77%) remained free of recurrent angina and 25 of these had follow-up angiograms (56%) at a mean of 172 days, two showing restenosis. Thus, the restenosis rate per patient in the symptomatic group (angiographic follow-up in 100%) was 77% and in the asymptomatic group (angiographic follow-up in 56%) was 8%. The restenosis rate in the subgroup with bailout stenting (n = 6) was 20% (angiographic follow-up in 83%). The overall restenosis rate per patient was 32% (overall angiographic follow-up in 66%). During the 6-mo follow-up period, one patient underwent elective CABG (1.7%), one sustained a non-Q myocardial infarction (1.7%), nine had repeat PTCA to the target vessel (15.5%), and there were no deaths. The event-free survival rate was 77%. Multiple stent implantation aided by high pressure stent deployment without ultrasound guidance and with adjunctive optimal antiplatelet therapy without oral anticoagulation seems to be a useful and effective revascularisation strategy to deal with long lesions and acute dissections with a high procedural success rate. The restenosis rate is acceptable and is not appreciably high as reported in previous studies from the "warfarin era."
Collapse
Affiliation(s)
- C K Ponde
- Department of Cardiology, Prince Charles Hospital, Brisbane, Australia
| | | | | | | | | | | | | | | |
Collapse
|
313
|
Schoebel FC, Gradaus F, Ivens K, Heering P, Jax TW, Grabensee B, Strauer BE, Leschke M. Restenosis after elective coronary balloon angioplasty in patients with end stage renal disease: a case-control study using quantitative coronary angiography. HEART (BRITISH CARDIAC SOCIETY) 1997; 78:337-42. [PMID: 9404246 PMCID: PMC1892250 DOI: 10.1136/hrt.78.4.337] [Citation(s) in RCA: 87] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To assess the rate of angiographic restenosis in patients with end stage renal disease after elective coronary angioplasty. DESIGN A retrospective case-control study of 20 patients with end stage renal disease and 20 sex and age matched controls without renal disease, who had undergone primarily successful coronary angioplasty. Control coronary angiography was performed regardless of worsening or renewed incidence of anginal symptoms. MAIN OUTCOME MEASURES Group comparison of coronary morphology, as evaluated by quantitative coronary angiography, and of cardiovascular risk factors. RESULTS The rate of angiographic restenosis was 60% in patients with renal disease and 35% in controls. In patients with end stage renal disease the following differences (mean (SD) were found versus controls: raised plasma fibrinogen (483 (101) v 326 (62) mg/dl, p < 0.001); raised plasma triglyceride (269 (163) v 207 (176) mg/dl, p < 0.01); smaller diameter of the coronary reference segment (2.59 (0.87) v 2.90 (0.55) mm, p < 0.10); smaller minimum luminal diameter of the dilated stenosis (0.77 (0.46) v 0.97 (0.27) mm, p < 0.05). Discriminant analysis showed that minimum luminal diameter before angioplasty (r = -0.79) and fibrinogen (r = +0.34) had the highest statistical association with restenosis. CONCLUSIONS The high rate of angiographic restenosis in patients with end stage renal disease seems to be related to the size of the vessel dilated and to an increased prothrombotic risk, as indicated by higher fibrinogen concentrations.
Collapse
Affiliation(s)
- F C Schoebel
- Medizinische Klinik, Heinrich-Heine Universität Düsseldorf, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
314
|
Währborg P. Percutaneous transluminal coronary angioplasty or coronary artery bypass grafting for coronary artery disease? SCAND CARDIOVASC J 1997; 31:201-11. [PMID: 9291538 DOI: 10.3109/14017439709041747] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- P Währborg
- Division of Cardiology, Sahlgrenska University Hospital, Göteborg, Sweden
| |
Collapse
|
315
|
|
316
|
|
317
|
Krumholz HM, Cohen DJ, Williams C, Baim DS, Brinker J, Cabin HS, Heuser R, Hirshfeld J, Leon MB, Moses J, Savage MP, Cleman M. Health after coronary stenting or balloon angioplasty: results from the Stent Restenosis Study. Am Heart J 1997; 134:337-44. [PMID: 9327686 DOI: 10.1016/s0002-8703(97)70065-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
This study was designed to compare health-related quality of life (HRQOL) in patients undergoing coronary stenting or balloon angioplasty in the randomized Stent Restenosis Study. The study sample was drawn from patients at nine U.S. clinical sites of the Stent Restenosis Study, a randomized trial comparing Palmaz-Schatz coronary stent implantation with conventional balloon angioplasty. One hundred ninety-nine consecutive patients were sent surveys 6 to 18 months after enrollment and 160 (80%) were returned. The survey sent to the patients included the Medical Outcomes Study 36-Item Short-Form Health Survey, the Canadian Cardiovascular Society Classification, and the Duke Activity Status Index. Although patients who underwent stenting had less angiographic restenosis and a tendency for fewer ischemic events, there were few differences in HRQOL after a mean of 456 days after randomization. The group that underwent stenting reported significantly less bodily pain than the group that underwent angioplasty (p = 0.02). Otherwise, there were no significant differences in generic or disease-specific measures. In a rating of their overall health, 47% of the group that underwent stenting and 45% of the group that underwent percutaneous transluminal coronary angioplasty reported very good or excellent health. In each group, 60% of the patients reported being symptom free from a cardiovascular perspective. This survey revealed no marked differences in long-term HRQOL between patients who underwent Palmaz-Schatz coronary stenting compared with those who underwent conventional angioplasty.
Collapse
Affiliation(s)
- H M Krumholz
- Department of Medicine, Yale School of Medicine, New Haven, CT 06520-8025, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
318
|
Hamasaki S, Abematsu H, Arima S, Tahara M, Kihara K, Shono H, Nakao S, Tanaka H. A new predictor of restenosis after successful percutaneous transluminal coronary angioplasty in patients with multivessel coronary artery disease. Am J Cardiol 1997; 80:411-5. [PMID: 9285650 DOI: 10.1016/s0002-9149(97)00387-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
With the goal of improving prediction of restenosis after percutaneous transluminal coronary angioplasty (PTCA) for multivessel coronary artery disease (CAD), we evaluated the usefulness of serial exercise treadmill tests. We previously reported that an increase in the deltaST/delta heart rate (HR) index at follow-up over the value obtained several days after PTCA was useful for detecting restenosis following PTCA for 1-vessel CAD. In that report, comparison of the deltaST/deltaHR index was made based on measurements from the lead disclosing the greatest ST displacement before PTCA. This method was not applicable to patients with multivessel CAD. Seventy-eight patients with multivessel CAD before and several days after PTCA and just before follow-up performed exercise treadmill tests. Simple HR-adjusted indexes of ST-segment depression during exercise (deltaST/deltaHR index) and the sum of the deltaST/deltaHR index in leads II, III, aVF, V4, V5, and V6 (sigma deltaST/deltaHR index) were determined. We compared the predictive power of an increase in sigma deltaST/deltaHR index at follow-up with that of a positive exercise treadmill test and a positive thallium scintigram for restenosis. At follow-up, 37 of the 78 patients showed restenosis. The sigma deltaST/deltaHR index had increased in 30 of these 37 patients (81%), and in 12 of the 41 patients (29%) without restenosis. An increase in sigma deltaST/deltaHR index had a significantly higher sensitivity than the other methods and a significantly higher specificity than a positive exercise treadmill test.
Collapse
Affiliation(s)
- S Hamasaki
- First Department of Internal Medicine, Faculty of Medicine, Kagoshima University, Japan
| | | | | | | | | | | | | | | |
Collapse
|
319
|
Benchimol D, Dubroca B, Dufourq P, Benchimol H, Couffinhal T, Dartigues JF, Bonnet J. Restenosis or rapid progression in non-dilated sites are not predictors of late spontaneous coronary events. Int J Cardiol 1997; 60:201-11. [PMID: 9226292 DOI: 10.1016/s0167-5273(97)00072-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The present study was designed to assess the prognostic value of clinical and angiographic factors, and especially restenosis or rapid progression in non-dilated sites, on major spontaneous coronary events at long-term follow-up after a first successful coronary angioplasty performed for angina pectoris. A second aim was to assess the prognostic factors and especially restenosis in asymptomatic patients after angioplasty. The first 352 consecutive patients undergoing a successful coronary angioplasty were selected and followed-up. The following variables: age, sex, unstable angina, previous myocardial infarction, diabetes, hypercholesterolemia, tobacco consumption, hypertension, fibrinogen, coronary extent, single or multiple dilatation, restenosis, new progression, clinical deterioration of anginal status just before angiographic restudy or asymptomatic status were subjected to a stepwise regression analysis. Restenosis (a loss of 30% in diameter and/or a return to a >50% stenosis) and progression in non-dilated segments (a 20% reduction in diameter) were assessed by a computer-assisted method. Cardiac death, new myocardial infarction or new unstable angina, at long-term follow-up after angiographic restudy, were regarded as spontaneous coronary events and pooled in a single dependent variable. Thus 41 patients had a coronary event. In the overall population, clinical deterioration of anginal status (p<0.001, relative risk: 3.65) and fibrinogen (p<0.05, relative risk: 1.03) were independent predictors of spontaneous coronary events. Restenosis or new progression were not predictors. In asymptomatic patients (n=187), fibrinogen (p<0.01, relative risk=1.06) was the only predictor and restenosis was not an independent predictor of spontaneous coronary events. The best predictor of spontaneous coronary events at long-term follow-up after a first successful coronary angioplasty is clinical deterioration in anginal status in the months following the procedure. Restenosis does not appear as an independent predictor. Rapid progression observed in non-dilated sites is not an important prognostic factor.
Collapse
Affiliation(s)
- D Benchimol
- Service de Cardiologie et des Maladies Vasculaires, Hôpital Cardiologique and Unité INSERM 441, Pessac, France
| | | | | | | | | | | | | |
Collapse
|
320
|
Kimura T, Kaburagi S, Tamura T, Yokoi H, Nakagawa Y, Yokoi H, Hamasaki N, Nosaka H, Nobuyoshi M, Mintz GS, Popma JJ, Leon MB. Remodeling of human coronary arteries undergoing coronary angioplasty or atherectomy. Circulation 1997; 96:475-83. [PMID: 9244215 DOI: 10.1161/01.cir.96.2.475] [Citation(s) in RCA: 137] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Recently, long-term constriction of the vessel has been suggested as an alternative mechanism of restenosis after coronary angioplasty. METHODS AND RESULTS To understand remodeling of human coronary arteries undergoing coronary angioplasty or atherectomy, serial intravascular ultrasonographic examinations were performed at preintervention and postintervention examinations and at 24 hours, 1 month, and 6 months. Complete serial data were obtained in 61 lesions (balloon angioplasty, 35 lesions; directional atherectomy, 26 lesions). Lumen area improved from 6.81+/-2.24 mm2 after intervention to 8.22+/-2.79 mm2 at 1 month (P=.0001) and decreased to 4.88+/-2.86 mm2 at 6 months (P=.0001). Vessel area enlarged from 17.32+/-5.35 mm2 after intervention to 19.39+/-5.33 mm2 at 1 month (P=.0001) and decreased to 16.33+/-5.54 mm2 at 6 months (P=.0001). Plaque+media area increased significantly from postintervention examination to 24 hours (10.51+/-4.38 versus 10.96+/-4.49 mm2, P=.0008) and from 24 hours to 6 months (10.96+/-4.49 versus 11.45+/-4.45 mm2, P=.03). Changes in lumen area in each study interval correlated more closely with changes in vessel area than with changes in plaque+media area. Restenotic lesions compared with nonrestenotic lesions had a greater decrease in the vessel area between 1 month and 6 months (-4.33+/-2.73 versus -2.49+/-2.15 mm2, P=.006) and greater increase in the plaque+media area both within 24 hours (0.84+/-1.22 versus 0.27+/-0.38 mm2, P=.04) and between 24 hours and 6 months (1.19+/-2.19 versus 0.18+/-1.46 mm2, P=.04). CONCLUSIONS; Remodeling after coronary angioplasty or atherectomy was characterized by early adaptive enlargement and late constriction of the vessel.
Collapse
Affiliation(s)
- T Kimura
- Department of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
321
|
Ormiston JA, Stewart FM, Roche AH, Webber BJ, Whitlock RM, Webster MW. Late regression of the dilated site after coronary angioplasty: a 5-year quantitative angiographic study. Circulation 1997; 96:468-74. [PMID: 9244214 DOI: 10.1161/01.cir.96.2.468] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Limited data are available on the changes that occur at the dilated site late after coronary angioplasty. The aim of this study was to evaluate with quantitative angiography the natural history of changes that occur in the dilated segment between "early" (approximately 6 months) and "late" (approximately 5 years) follow-up after angioplasty. METHODS AND RESULTS Of 127 consecutive patients (174 lesions) with successful angioplasty, 125 underwent early angiography. Three patients subsequently died, and 24 underwent revascularization surgery or repeated angioplasty, giving a study-eligible population of 98 patients. Quantitative angiographic analysis was performed before and immediately after angioplasty and at early and late follow-up in the study population of 84 patients (115 lesions), which was 86% of study-eligible patients. Mean lesion diameter stenosis decreased from 36.3+/-14.2% at early to 29.6+/-13.5% at late follow-up (P<.0001). No lesion developed late restenosis by the 50% diameter loss criterion. Late regression was related to stenosis severity at early angiography (r=-.58, P<.001). Subgroups at early angiography of 40% to 49% stenosis and > or = 50% stenosis showed significant regression at late angiography. CONCLUSIONS Lesion regression at the dilated site is common late after angioplasty. The more severe a stenosis is at early angiography, the more likely the chance that there will be late regression. A strategy of watchful waiting may be appropriate for patients with restenotic lesions of borderline severity.
Collapse
Affiliation(s)
- J A Ormiston
- Green Lane Hospital, Epsom, Auckland, New Zealand
| | | | | | | | | | | |
Collapse
|
322
|
Aikawa M, Sakomura Y, Ueda M, Kimura K, Manabe I, Ishiwata S, Komiyama N, Yamaguchi H, Yazaki Y, Nagai R. Redifferentiation of smooth muscle cells after coronary angioplasty determined via myosin heavy chain expression. Circulation 1997; 96:82-90. [PMID: 9236421 DOI: 10.1161/01.cir.96.1.82] [Citation(s) in RCA: 76] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The pathophysiology of phenotypic modulation of smooth muscle cells (SMCs) involved in restenosis after angioplasty is not well understood. Smooth muscle myosin heavy chain (SM MHC) isoforms (SM1 and SM2) are specific markers for SMC differentiation. In particular, SM2 is useful as a marker of mature SMCs. SMemb is a nonmuscle myosin heavy chain (NM MHC) whose expression is upregulated in immature or activated SMC. METHODS AND RESULTS To determine SMC phenotypes in neointimal tissues after percutaneous transluminal coronary angioplasty (PTCA), we performed immunohistochemistry on human coronary arteries with antibodies against alpha-SM actin, SM1, SM2, and SMemb. Tissues were obtained from six autopsied patients and from atherectomy specimens from 16 patients who had undergone PTCA. Medial SMCs were positive for alpha-actin, SM1, and SM2. Expression of SM1 and SM2 in the neointima varied with the time after intervention, whereas alpha-actin was constitutively expressed in all cases studied. Neointimal cells at 16 and 20 days after PTCA contained alpha-actin but little or no SM1 or SM2, indicating that these cells modulated their phenotype to the immature state. Neointimal SMCs recovered SM MHC expression, first SM1 and then SM2, by 6 months after PTCA. Increased expression of SMemb was found in the neointima but without apparent relationship to the time after PTCA. CONCLUSIONS Neointimal SMCs show features of an undifferentiated state, indicated by altered expression of SM MHC, and undergo redifferentiation in a time-dependent manner. The expression of SM MHC isoforms provides insight into the biology of healing after angioplasty and furnishes useful tools for the understanding of the roles of differentiation and phenotypic modulation of SMCs in human vascular lesions.
Collapse
Affiliation(s)
- M Aikawa
- Third Department of Internal Medicine, University of Tokyo, Faculty of Medicine, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
323
|
Camenzind E, Bakker WH, Reijs A, van Geijlswijk IM, Boersma E, Kutryk MJ, Krenning EP, Roelandt JR, Serruys PW. Site-specific intracoronary heparin delivery in humans after balloon angioplasty. A radioisotopic assessment of regional pharmacokinetics. Circulation 1997; 96:154-65. [PMID: 9236430 DOI: 10.1161/01.cir.96.1.154] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Demonstration and quantification of site-specific intracoronary administration of compounds has been confined thus far to the experimental animal laboratory. The aim of this study was to describe a scintigraphic method to demonstrate site-specific intracoronary drug delivery in humans. The methods allow on-line visualization and off-line quantification of site-specifically infused gamma-emitting compounds. METHODS AND RESULTS In 12 patients after balloon angioplasty, 99mTc-labeled heparin was administered at the site of dilatation by use of a coil balloon. Both the infusion period and the washout period after the end of infusion were monitored with a gamma-camera. A curve of counts per pixel as a function of time was derived that showed an accumulation phase during infusion followed by washout phase after the end of infusion. Both phases were fitted by regression analysis and showed a linear accumulation pattern and a biexponential washout pattern. After correction for background counts, 99mTc decay, and body attenuation, peak heparin amount and regional bioavailability were calculated. Peak amount was defined as the initial point of the slow washout component of the biexponential curve (elimination component), and regional bioavailability was defined as the area under the curve of accumulation and washout phase. Half-life and retention time, define as seven half-lives, were obtained by use of the elimination component after correction for 99mTc decay. Mean peak delivered amount was 45 +/- 44 IU (236 +/- 228 micrograms), corresponding to an efficiency of delivery ranging from 1% to 8% of the totally infused dose. Total regionally bioavailable heparin reached 244 +/- 194 IU.h (1.28 +/- 1.01 mg.h). Retention time varied from 12 to 90 hours (mean, 50:33 +/- 22:50 hours:minutes). CONCLUSIONS Site-specific intracoronary heparin delivery after angioplasty by means of the coil balloon was demonstrated in humans, and regional pharmacokinetics was quantified by use of a radioisotopic technique.
Collapse
Affiliation(s)
- E Camenzind
- Thoraxcenter, University Hospital Dijkzigt, Rotterdam, Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
324
|
Camenzind E, Bakker WH, Reijs A, van Geijlswijk IM, Foley D, Krenning EP, Roelandt JR, Serruys PW. Site-specific intravascular administration of drugs: history of a method applicable in humans. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1997; 41:342-7. [PMID: 9213034 DOI: 10.1002/(sici)1097-0304(199707)41:3<342::aid-ccd16>3.0.co;2-p] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Demonstration and quantification of site-specific intracoronary administration of pharmacological compounds has been limited thus far to animal experimental models. Recently, a method applicable in humans has been developed. The aim of this study is to give an overview on the available methods to visualize and quantify intravascularly administered "labeled" drugs in animals and to describe the historical development of a method now applied in the clinical arena. The potential of this approach is briefly summarized.
Collapse
Affiliation(s)
- E Camenzind
- Thoraxcenter, University Hospital Dijkzigt, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
325
|
Consigny PM. Placement of endothelial cells on the luminal surface of denuded arteries in vitro and in vivo. J Vasc Interv Radiol 1997; 8:595-604. [PMID: 9232577 DOI: 10.1016/s1051-0443(97)70618-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
PURPOSE Experiments were performed to determine if the percutaneous placement of endothelial cells on denuded arterial surfaces is feasible. MATERIALS AND METHODS For in vitro adhesion assays, rabbit microvascular endothelial cells were stained with a fluorescent marker and placed on the luminal surface of disks of denuded rabbit aorta. At varying times thereafter, the nonadherent cells were removed, and the adherent cells were quantitated with use of fluorescence microscopy. For in vivo studies, angioplasty was performed on external iliac arteries in five rabbits, and a double-balloon catheter, positioned at the dilatation site, was used to deliver fluorescent rabbit microvascular endothelial cells. Ten minutes (n = 2), 1 hour (n = 2), 1 day (n = 1), or 3 days (n = 1) after cell placement, the number of fluorescent cells remaining on each artery was determined. RESULTS In vitro rabbit microvascular endothelial cell attachment was (a) serum-dependent, peaking with media containing 25% autologous serum; (b) time-dependent, peaking at 30 minutes; and (c) cell density-dependent. In vivo rabbit microvascular endothelial cell attachment was (a) noncircumferential, (b) appeared to be gravity-dependent, and (c) appeared unchanged over 3 days with respect to number of cells per cross-section and length of artery having endothelium. CONCLUSIONS Percutaneous delivery of endothelial cells onto denuded arterial surfaces with use of optimal conditions is feasible and these cells remain adherent for at least 3 days.
Collapse
Affiliation(s)
- P M Consigny
- Department of Radiology, Jefferson Medical College, Philadelphia, PA, USA
| |
Collapse
|
326
|
Morguet AJ, Andreas S, Gabriel RE, Nyga R, Kreuzer H. [Development and evaluation of a spectroscopy system for classification of laser-induced arterial fluorescence spectra]. BIOMED ENG-BIOMED TE 1997; 42:176-82. [PMID: 9312308 DOI: 10.1515/bmte.1997.42.6.176] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The present study evaluated the potential of fluorescence guidance of laser angioplasty without using a second laser for fluorescence excitation. A prototype spectroscopy system with a grating spectrograph, microchannel plate, CCD array and digital image processor on a personal computer was developed and coupled to a clinical XeCl excimer laser. Using multifibre catheters, specimens of human aorta were ablated in physiological saline and blood. The spectra thus generated were recorded and validated histologically. Five types of spectra could be differentiated. Based on a training set, classification algorithms were developed using multiple linear regression and linear discriminant analysis with intensity ratios as predictor variables. Discriminant analysis yielded prospective classification of the remaining validation spectra with high sensitivity and specificity for each type. These data demonstrate that fluorescence spectroscopy during excimer laser ablation at 308 nm does not require a diagnostic laser. Principal types of atherosclerotic lesions and the media can be differentiated spectroscopically in physiological saline and blood.
Collapse
Affiliation(s)
- A J Morguet
- Abteilung Kardiologie und Pulmonologie, Zentrum Innere Medizin, Georg-August-Universität Göttingen
| | | | | | | | | |
Collapse
|
327
|
Caplice NM, Aroney CN, Bett JH, Cameron J, Campbell JH, Hoffmann N, McEniery PT, West MJ. Growth factors released into the coronary circulation after vascular injury promote proliferation of human vascular smooth muscle cells in culture. J Am Coll Cardiol 1997; 29:1536-41. [PMID: 9180116 DOI: 10.1016/s0735-1097(97)00076-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES This study sought to 1) assess in vivo release of platelet-derived growth factor (PDGF) and basic fibroblast growth factor (bFGF) into the coronary circulation after vascular injury in human subjects; and 2) evaluate mitogenic effects of PDGF and bFGF on the patient's own vascular smooth muscle cells (VSMCs). BACKGROUND Circumstantial evidence suggests involvement of PDGF and bFGF peptides in the neointimal response to vascular injury. To date, no study has shown biologically active growth factors within the coronary circulation after vascular injury in human subjects. METHODS In 18 patients, plasma PDGF AB, platelet factor 4 (PF4) and beta-thromboglobulin (beta-TG) levels were measured in coronary sinus blood obtained before and up to 30 min after angioplasty. In five patients undergoing atherectomy, coronary sinus serum was added to cultured VSMCs derived from atherectomy tissue to assess the mitogenic potential of the serum. Mitogenicity attributable to PDGF and bFGF was determined using neutralizing antibodies to these factors. PDGF A, PDGF B and bFGF were localized within the atherectomy tissue using immunocytochemical analysis. RESULTS Before angioplasty, PDGF AB, PF4 and beta-TG levels were elevated threefold in patients scheduled for angioplasty compared with those in control patients (p < 0.01). Within 5 min of angioplasty, PDGF AB levels increased twofold and returned toward preangioplasty levels at 30 min; PF4 and beta-TG levels remained elevated. Serum obtained at 30 min after atherectomy showed a sixfold increase in mitogenicity compared with preatherectomy serum (p = 0.01). This increase in mitogenicity was reduced by 20%, 40% and 65% in the presence of neutralizing antibodies to PDGF, bFGF and PDGF + bFGF, respectively. PDGF A, PDGF B and bFGF were visualized within the intima of the atherectomy tissue. CONCLUSIONS The change in plasma PDGF level is consistent with first-phase release of PDGF after vascular injury. The increase in mitogenicity of serum suggests that PDGF and bFGF are biologically active.
Collapse
Affiliation(s)
- N M Caplice
- Department of Medicine and Centre for Research in Vascular Biology, University of Queensland, Brisbane, Australia
| | | | | | | | | | | | | | | |
Collapse
|
328
|
Chen D, Krasinski K, Sylvester A, Chen J, Nisen PD, Andrés V. Downregulation of cyclin-dependent kinase 2 activity and cyclin A promoter activity in vascular smooth muscle cells by p27(KIP1), an inhibitor of neointima formation in the rat carotid artery. J Clin Invest 1997; 99:2334-41. [PMID: 9153274 PMCID: PMC508071 DOI: 10.1172/jci119414] [Citation(s) in RCA: 149] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Abnormal proliferation of vascular smooth muscle cells (VSMCs) contributes to intimal hyperplasia during atherosclerosis and restenosis, but the endogenous cell cycle regulatory factors underlying VSMC growth in response to arterial injury are not well understood. In the present study, we report that downregulation of cyclin-dependent kinase 2 (cdk2) activity in serum-deprived VSMCs was associated with the formation of complexes between cdk2 and its inhibitory protein p27(KIP1) (p27). Ectopic overexpression of p27 in serum-stimulated VSMCs resulted in the inhibition of cdk2 activity and repression of cyclin A promoter activity. Collectively, these findings indicate that p27 may contribute to VSMC growth arrest in vitro. Using the rat carotid model of balloon angioplasty, a marked upregulation of p27 was observed in injured arteries. High levels of p27 expression in the media and neointima correlated with downregulation of cdk2 activity at 2 wk after angioplasty, and adenovirus-mediated overexpression of p27 in balloon-injured arteries attenuated neointimal lesion formation. Thus, the inhibition of cdk2 function and repression of cyclin A gene transcription through the induction of the endogenous p27 protein provides a mechanism for the inhibition of VSMC growth at late time points after angioplasty.
Collapse
Affiliation(s)
- D Chen
- Department of Medicine (Cardiology), St. Elizabeth's Medical Center, Tufts University School of Medicine, Boston, Massachusetts 02135, USA
| | | | | | | | | | | |
Collapse
|
329
|
Lee TM, Chu CC, Hsu YM, Chen MF, Liau CS, Lee YT. Exaggerated luminal loss a few minutes after successful percutaneous transluminal coronary angioplasty in patients with recent myocardial infarction compared with stable angina: an intracoronary ultrasound study. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1997; 41:32-9. [PMID: 9143764 DOI: 10.1002/(sici)1097-0304(199705)41:1<32::aid-ccd9>3.0.co;2-b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
This study investigates the mechanisms of exaggerated acute luminal loss after successful coronary angioplasty in patients with recent myocardial infarction compared with stable angina by angiography and intracoronary ultrasound (ICUS). We studied 15 consecutive patients (group 1) who, after a successful thrombolysis for myocardial infarction, underwent delayed (8 +/- 2 days after the myocardial infarction) successful balloon coronary angioplasty. Group 1 patients were individually matched with 15 stable angina patients (group 2). The percentage of stenosis and acute luminal loss were measured by quantitative coronary analysis. The ultrasound characteristics of lumen pathology were described as soft, hard, calcified, eccentric, concentric, thrombotic, and dissection lesions. Matching by stenosis location, reference diameter, sex, and age resulted in 2 comparable groups of 15 lesions with identical baseline characteristics. Immediately after percutaneous transluminal coronary angioplasty (PTCA), the minimal luminal diameter increased from 0.5 +/- 0.3 mm to 2.4 +/- 0.3 mm and from 0.5 +/- 0.2 mm to 2.4 +/- 0.3 mm in groups 1 and 2, respectively. Similar balloon sizes were used in both groups. The acute luminal loss (the difference between the maximal dilated balloon diameter and the minimal luminal diameter) immediately after PTCA was 0.4 +/- 0.2 mm and 0.3 +/- 0.3 mm (14 +/- 8% and 10 +/- 11% of balloon size) (P = not significant [NS]) in groups 1 and 2, respectively. After ICUS (mean 24 min after the last balloon deflation), the acute luminal loss was 0.9 +/- 0.3 mm and 0.5 +/- 0.4 mm (29 +/- 11% and 17 +/- 8% of balloon size) (P = 0.01) in groups 1 and 2, respectively. There was a significantly higher prevalence of intracoronary thrombus formation as detected by ICUS in group 1 compared with group 2 (80% vs. 20%; P < 0.001). In matched groups of successfully treated coronary angioplasty, patients with recent myocardial infarction had a similar magnitude of acute gained luminal loss immediately after the procedure. However, an exaggerated luminal loss a few minutes after the last balloon deflation in patients with recent myocardial infarction was noted because of mural thrombus formation compared with patients with stable angina.
Collapse
Affiliation(s)
- T M Lee
- Center for Cardiovascular Research, College of Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | | | | | | | | | | |
Collapse
|
330
|
Ueno H, Yamamoto H, Ito S, Li JJ, Takeshita A. Adenovirus-mediated transfer of a dominant-negative H-ras suppresses neointimal formation in balloon-injured arteries in vivo. Arterioscler Thromb Vasc Biol 1997; 17:898-904. [PMID: 9157953 DOI: 10.1161/01.atv.17.5.898] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Abnormal migration and proliferation of arterial smooth muscle cells may be a central event in inflammatory proliferative arterial diseases such as atherosclerosis and restenosis after angioplasty. The proto-oncogene c-H-ras is considered to be a key transducer in various growth-signaling events. We constructed an adenoviral vector (AdexCAHRasY57) expressing a potent dominant-negative mutated form of c-H-ras in which tyrosine replaces aspartic acid at residue 57. Infection of smooth muscle cells with AdexCAHRasY57 produced a large quantity of H-ras-p21, completely inhibited serum-stimulated activation of mitogen-activated protein kinase, and abolished the DNA synthesis in response to serum mitogens. However, a surge of intracellular Ca2+ concentration in response to platelet-derived growth factor was not affected, suggesting that some cellular functions were preserved. When we applied AdexCAHRasY57 into balloon-injured rat carotid arteries from inside the lumen, neointimal formation was significantly reduced (neointima/media ratio: 0.28) compared with that (1.50) in arteries treated with either injury alone or injury and infection with a control adenovirus, AdexCALacZ, expressing bacterial beta-galactosidase. Our results suggest that adenovirus-mediated arterial transfer of dominant-negative H-ras may be a practical form of effective molecular intervention for proliferative arterial diseases.
Collapse
Affiliation(s)
- H Ueno
- Department of Cardiology, Kyushu University School of Medicine, Fukuoka, Japan.
| | | | | | | | | |
Collapse
|
331
|
Rozenman Y, Gilon D, Sapoznikov D, Lotan C, Mosseri M, Hasin Y, Gotsman MS. Angiographic deterioration of target coronary artery narrowing as a result of percutaneous balloon angioplasty. Am Heart J 1997; 133:575-9. [PMID: 9141380 DOI: 10.1016/s0002-8703(97)70153-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
We evaluated the long-term angiographic outcome of balloon angioplasty by comparing original and follow-up target coronary narrowing. Rather than using restenosis to determine outcome, as in most angioplasty studies, we took an unusual approach and analyzed outcome in terms that are commonly used in progression and regression studies after medical interventions. Quantitative angiographic measurements were undertaken in 315 narrowings with an initial diameter stenosis <90% before and after angioplasty and at follow-up. Angiographic deterioration (>10% increase in follow-up diameter stenosis) was identified in 44 (14%) narrowings. Angiographic deterioration was not influenced by age, sex, risk factors, lipid profile, or the indication for angioplasty. Deterioration was also not predicted by the severity, length, or the location of the narrowing. The deteriorating narrowings had a higher recoil after dilatation compared with narrowings with angiographic improvement (21% +/- 31% vs 12% +/- 17%, p = 0.006); the residual stenosis after angioplasty was therefore higher. The late loss was also significantly increased compared with narrowings with angiographic improvement (65% +/- 26% vs 8% +/- 24%, p < 0.001). We conclude that the incidence of angiographic deterioration of coronary disease as a result of restenosis is uncommon but not negligible. Interventional cardiologists should resist the temptation to dilate mild, silent coronary narrowings because the procedure might have an unfavorable angiographic (and probably clinical) effect.
Collapse
Affiliation(s)
- Y Rozenman
- Cardiology Department, Hadassah University Hospital, Ein Kerem, Jerusalem, Israel
| | | | | | | | | | | | | |
Collapse
|
332
|
Kaneko E, Yuan C, Skinner MP, Raines EW, Ross R. Serial magnetic resonance imaging of experimental atherosclerosis allows visualization of lesion characteristics and lesion progression in vivo. Ann N Y Acad Sci 1997; 811:245-52; discussion 252-4. [PMID: 9186602 DOI: 10.1111/j.1749-6632.1997.tb52006.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Affiliation(s)
- E Kaneko
- Department of Pathology, University of Washington School of Medicine, Seattle 98195-7470, USA
| | | | | | | | | |
Collapse
|
333
|
Ishiwata S, Tukada T, Nakanishi S, Nishiyama S, Seki A. Postangioplasty restenosis: platelet activation and the coagulation-fibrinolysis system as possible factors in the pathogenesis of restenosis. Am Heart J 1997; 133:387-92. [PMID: 9124158 DOI: 10.1016/s0002-8703(97)70178-9] [Citation(s) in RCA: 70] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
We investigated the relationship between changes in hemostatic factors and postangioplasty restenosis by evaluating plasma levels of P-selectin, beta-thromboglobulin (BTG), and other markers of the coagulation-fibrinolysis system. Seventy-three consecutive patients (56 men and 17 women) undergoing elective percutaneous transluminal coronary angioplasty (PTCA) were enrolled in this study. Patients with acute myocardial infarction within the previous month, unstable angina pectoris, chronic total occlusion, target lesions involving saphenous vein grafts, or coronary artery bypass grafting within the previous 6 months were excluded. Fasting blood samples were obtained before elective PTCA and at follow-up coronary angiography. In patients with restenosis, plasminogen activator inhibitor type-1 (PAI-1) levels were significantly higher (88.2 +/- 36.1 vs 118.5 +/- 50.0 ng/dl; p< 0.05) and plasmin-plasmin inhibitor complex (PIC) levels were significantly lower (0.76 +/- 0.26 vs 0.61 +/- 0.26 microg/ml; p < 0.02) than at baseline. P-Selectin levels were also significantly higher (192 +/- 68 vs 239 +/- 99 ng/ dl; p<0.01) and a positive correlation existed between P-selectin and BTG levels (r= 0.43; p< 0.05). The higher PAI-1 and lower PIC levels in patients with postangioplasty restenosis suggest that impaired fibrinolysis may play a role in the pathogenesis of restenosis, whereas the positive correlation between P-selectin and BTG levels implies a role for activated platelets in restenosis.
Collapse
Affiliation(s)
- S Ishiwata
- Cardiovascular Center, Toranomon Hospital, Tokyo, Japan
| | | | | | | | | |
Collapse
|
334
|
JUILLIÈRE YVES, DIBON OLIVIER, EDEL FRANÇOIS, BERDER VÉRONIQUE, CADOR ROMAIN, DANCHIN NICOLAS, CHERRIER FRANÇOIS. The Feasibility of Systematic Use of a Combined Diagnostic and Interventional 6 Fr Guide Catheter in Patients with Suspected Coronary Restenosis. J Interv Cardiol 1997. [DOI: 10.1111/j.1540-8183.1997.tb00017.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
335
|
Park SW, Park SJ, Hong MK, Kim JJ, Cho SY, Jang YS, Kim KB, Kim KS, Oh DJ, Oh BH, Kang JC. Coronary stenting (Cordis) without anticoagulation. Am J Cardiol 1997; 79:901-4. [PMID: 9104903 DOI: 10.1016/s0002-9149(97)00017-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
We evaluated the effect of antithrombotic regimens on subacute thrombosis and short-term clinical courses after successful implantation of the Cordis coronary stent, which is a flexible, balloon expandable, radiopaque tantalum stent. Two hundred seventy-five consecutive patients with 290 lesions were treated with 356 Cordis stent implantations. According to poststent antithrombotic regimen, patients were divided into 3 groups; 165 patients with 175 lesions received aspirin 200 mg/day, ticlopidine 500 mg/day, and warfarin for 1 month (group 1), 66 patients with 69 lesions received aspirin and ticlopidine (group 2), and 44 patients with 46 lesions received aspirin alone (group 3) after successful Cordis stenting. The overall procedural success rates were 97.7% in group 1, 98.6% in group 2, and 100% in group 3. More than 65% of the patients were eligible for elective stenting. The overall rate of stent thrombosis was 1.8%: 1.2% in patients assigned to the treatment with aspirin, ticlopidine, and warfarin; 0% in patients with aspirin and ticlopidine; and 6.8% in patients assigned to the treatment with aspirin alone. In conclusion, the Cordis coronary stent is an effective endovascular stent in various clinical indications including unstable angina and acute myocardial infarction. Antiplatelet therapy using aspirin and ticlopidine after successful Cordis coronary stenting is a promising alternative to anticoagulation therapy to overcome the drawbacks of stenting. However, poststent antithrombotic therapy with aspirin alone is associated with a significant rate of stent thrombosis.
Collapse
Affiliation(s)
- S W Park
- Department of Internal Medicine, University of Ulsan, College of Medicine, Seoul, Korea
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
336
|
Bosmans JM, Kockx MM, Vrints CJ, Bult H, De Meyer GR, Herman AG. Fibrin(ogen) and von Willebrand factor deposition are associated with intimal thickening after balloon angioplasty of the rabbit carotid artery. Arterioscler Thromb Vasc Biol 1997; 17:634-45. [PMID: 9108775 DOI: 10.1161/01.atv.17.4.634] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The aim of the study was to assess the contribution of thrombus incorporation into neointimal thickening in the rabbit carotid artery after deep vascular injury induced by balloon angioplasty compared with superficial vascular injury induced by a perivascular collar. Besides CD 31 (PECAM 1), vimentin, alpha-smooth muscle actin, rabbit anti-macrophage monoclonal antibody and proliferating cell nuclear antigen, fibrin(ogen) and von Willebrand factor (vWF) deposition was assessed immunohistochemically. Angioplasty was performed in 47 rabbits and evaluated immediately (n = 7), after 6 hours (n = 4), and after 1 (n = 7), 2 (n = 9), or 3 (n = 20) weeks. A collar was placed in 29 rabbits and evaluated immediately (n = 5), after 6 hours (n = 5), and after 1 (n = 7), 2 (n = 10), or 3 (n = 2) weeks. After dilatation, the arteries were extensively denuded of endothelium, the internal elastic membrane was ruptured and blood-filled clefts were present in the media, pointing to deep vascular (type III) injury. Six hours later, mural fibrin(ogen) thrombi were formed, specially at sites with severe damage. This fibrin(ogen) matrix became infiltrated by phagocytes and smooth muscle cells. A luminal cap covered by regenerating endothelium was formed, demonstrating increased immunoreactivity to vWF. vWF was deposited in the extracellular neointimal spaces. Fibrin(ogen) thrombus deposition and incorporation appeared to be protracted phenomena for at least 2 weeks. After collar placement, minimal endothelial denudation was documented, pointing to focal superficial (type I) vascular injury. In subsequent weeks, neointimal thickening was associated with vWF deposition but not with fibrin(ogen) thrombus incorporation. In conclusion, mural fibrin(ogen) thrombus formation and incorporation contribute to neointima formation after deep vascular injury and seem to occur for several weeks after the initial insult.
Collapse
Affiliation(s)
- J M Bosmans
- Department of Cardiology, University of Antwerp, Wilrijk, Belgium
| | | | | | | | | | | |
Collapse
|
337
|
Verin V, Urban P, Popowski Y, Schwager M, Nouet P, Dorsaz PA, Chatelain P, Kurtz JM, Rutishauser W. Feasibility of intracoronary beta-irradiation to reduce restenosis after balloon angioplasty. A clinical pilot study. Circulation 1997; 95:1138-44. [PMID: 9054842 DOI: 10.1161/01.cir.95.5.1138] [Citation(s) in RCA: 103] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND With the aim of decreasing the incidence of restenosis after coronary balloon angioplasty, we developed a technique of intracoronary beta-irradiation using an endoluminally centered pure metallic 90Y source. The purpose of the present study was to evaluate the clinical feasibility and safety profile of this approach with a dose of 18 Gy delivered to the inner arterial surface. METHODS AND RESULTS Between June 21 and November 15, 1995, fifteen patients (6 women and 9 men; mean age, 71 +/- 5 years) underwent intracoronary beta-irradiation immediately after a conventional percutaneous transluminal coronary angioplasty (PTCA) procedure. The PTCA/irradiation procedure was technically feasible in all attempted cases, and the delivery of the 18 Gy dose was accomplished without complications. In 4 patients, the intervention was completed through intra-arterial stent implantation because of dissection induced by the initial PTCA. During the follow-up period of 178 +/- 17 days (range, 150 to 225 days), no complication occurred that could be attributed to radiation therapy. No aneurysm or angiographically detectable thrombus was observed in any of the irradiated arterial segments. The clinical event rate (4 of 15 patients underwent further target lesion revascularization) and the angiographic follow-up (6 of 15 patients had a > 50%-diameter stenosis at the previously treated site) did not suggest a marked impact on the expected restenosis rate. CONCLUSIONS This early experience demonstrates that our approach is feasible, and no side effects attributable to radiation were noted during a 6-month period of follow-up. Whether higher doses of beta-irradiation will favorably affect post-PTCA restenosis in patients must await further evaluation.
Collapse
Affiliation(s)
- V Verin
- Cardiology Center, University Hospital, Geneva, Switzerland
| | | | | | | | | | | | | | | | | |
Collapse
|
338
|
Imanishi T, Arita M, Hamada M, Tomobuchi Y, Hano T, Nishio I. Effects of locally administration of argatroban using a hydrogel-coated balloon catheter on intimal thickening induced by balloon injury. JAPANESE CIRCULATION JOURNAL 1997; 61:256-62. [PMID: 9152775 DOI: 10.1253/jcj.61.256] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The purpose of this study was to evaluate the inhibitory effects of locally delivered argatroban, a competitive inhibitor of thrombin-induced platelet activation, on intimal proliferation after balloon injury. A hydrogel-coated balloon catheter was immersed 3 times in an argatroban/saline solution (1, 0.1, or 0.01 mg/ml) for 60 s and inflated at 6 atm pressure for 1 min in the rabbit common carotid artery. Immersion in a saline solution without drug followed by the same procedure served as a control. Accumulation of argatroban in the vascular wall was confirmed by chemical determination using high-performance liquid chromatography (HPLC). The concentration of argatroban in the vessel wall immediately after deflation after balloon immersion in solutions of 1 and 0.1 mg/ml was 14.8 +/- 10.9 and 5.5 +/- 4.6 nmol/g wet weight of artery, respectively. Argatroban was not detected in arteries treated with a balloon that had been immersed in the 0.01 mg/ml argatroban/saline solution. Intima-media area ratios 20 days after balloon injury in the groups treated with 1 mg/ml (n = 8) and 0.1 mg/ml (n = 6) agratoban were significantly smaller than that in the groups treated with 0.01 mg/ml (n = 7) argatroban or saline (n = 8) (0.35 +/- 0.11, 0.50 +/- 0.17, 1.24 +/- 0.39, and 1.35 +/- 0.43, respectively; p < 0.001). These data suggest that locally administered argatroban dose-dependently inhibits intimal thickening in a rabbit model of carotid artery injury.
Collapse
Affiliation(s)
- T Imanishi
- Department of Medicine, Wakayama Medical College, Japan
| | | | | | | | | | | |
Collapse
|
339
|
Simon DI, Xu H, Ortlepp S, Rogers C, Rao NK. 7E3 monoclonal antibody directed against the platelet glycoprotein IIb/IIIa cross-reacts with the leukocyte integrin Mac-1 and blocks adhesion to fibrinogen and ICAM-1. Arterioscler Thromb Vasc Biol 1997; 17:528-35. [PMID: 9102172 DOI: 10.1161/01.atv.17.3.528] [Citation(s) in RCA: 150] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Recent clinical trials suggest that blockade of integrins is a promising strategy for the treatment of acute coronary syndromes. Administration of 7E3 monoclonal antibody (mAb) Fab fragment (c7E3 Fab) directed against platelet integrin IIb/IIIa (alpha IIb beta 3, CD41/CD61) reduces acute ischemic complications of coronary angioplasty and clinical restenosis at 6 months. However, 7E3 mAb is not selective for platelet IIb/IIIa but also cross-reacts with the leukocyte integrin Mac-1 (alpha M beta 2, CD11b/CD18) and the vitronectin receptor (alpha v beta 3, CD51/CD61). Information regarding how this mAb may affect other cells important in vascular repair is scant. Potential interactions of c7E3 Fab with inflammatory (i.e., monocytes and neutrophils), vascular smooth muscle, and endothelial cells may contribute to the in vivo actions of c7E3 Fab. In this study we explored the binding of 7E3 to monocytic cells and the functional effect of 7E3 and c7E3 Fab on Mac-1-mediated adhesion to fibrinogen (FGN) and intercellular adhesion molecule-1 (ICAM-1), ligands abundant in the injured vessel wall. Flow cytometry demonstrated that 7E3 bound to THP-1 monocytic cells and identified a subpopulation (approximately 10%) of Mac-1 that was qualitatively similar to that recognized by CBRM1/5, a mAb directed to an activation-specific neoepitope present on a subset of Mac-1 molecules. mAb 7E3 bound to K562 cells transfected with just the alpha subunit (CD11b) of Mac-1 but not to nontransfected cells, confirming a direct interaction between 7E3 and Mac-1. mAb 7E3 and c7E3 Fab blocked the adhesion of Mac-1-bearing cells to FGN (80 +/- 11% and 78 +/- 9% inhibition, respectively) and ICAM-1 (62 +/- 14% and 62 +/- 17%). Both 7E3 and c7E3 Fab significantly inhibited (70 +/- 6% and 62 +/- 26%) soluble FGN binding to human peripheral blood monocytes. Thus, c7E3 Fab cross-reacts with the CD11b subunit of Mac-1 and interrupts cell-extracellular matrix and cell-cell adhesive interactions and may thereby influence the recruitment of circulating monocytes to sites of vessel injury. Given the recent evidence that adherent and infiltrating monocyte number directly correlates with the extent of neointimal hyperplasia, inhibition of Mac-1-dependent adhesion and IIb/IIIa-dependent function by c7E3 Fab may jointly contribute to the regulation of vascular repair and to the sustained clinical benefits observed with c7E3 Fab after angioplasty.
Collapse
Affiliation(s)
- D I Simon
- Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | | | | | | | | |
Collapse
|
340
|
TOMARU TAKANOBU, UCHIDA YASUMI. Economic and Ethical Aspects of Interventional Cardiology in Japan: Cost-Effectiveness of New Interventional Therapy in Japan. J Interv Cardiol 1997. [DOI: 10.1111/j.1540-8183.1997.tb00009.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
341
|
Legrand V, Raskinet B, Laarman G, Danchin N, Morel MA, Serruys PW. Diagnostic value of exercise electrocardiography and angina after coronary artery stenting. Benestent Study Group. Am Heart J 1997; 133:240-8. [PMID: 9023171 DOI: 10.1016/s0002-8703(97)70214-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
To determine whether metallic stent implantation within a coronary artery modifies the accuracy of angina or exercise test results in predicting stenosis, we studied 172 patients assigned to stent implantation and 153 patients assigned to balloon angioplasty enrolled in the Benestent trial comparing de novo stenting with conventional balloon angioplasty. Sensitivity and specificity curves were constructed for the prediction of percentage diameter stenosis and minimal lumen diameter. Receiver-operator curves were constructed for comparison of diagnostic accuracy. Identical exercise load and duration were achieved in the two groups, despite a better angiographic result in patients treated with a stent. Similarly, the diagnostic accuracy of clinical symptoms or exercise test results as a function of the angiographic results were similar in patients with and patients without a stent. The intersection points of the sensitivity and specificity curves for recurrent angina or ST-segment depression were 72% to 77%. The corresponding cut-off points for percentage diameter stenosis were, respectively, 52% and 50% for patients with and without a stent (1.35 and 1.50 mm for minimal lumen diameter). We conclude that the presence of an intracoronary stent does not affect the diagnostic accuracy of recurrent angina or exercise-induced ST depression in predicting residual stenosis. We also conclude that exercise tolerance is similar after balloon angioplasty, with or without stenting, despite a better angiographic outcome in the group receiving a stent, suggesting a minimal threshold beyond which the patient is no longer at risk for ischemia during exercise.
Collapse
Affiliation(s)
- V Legrand
- Department of Cardiology, Centre Hospitalier Universitaire Sart-Tilman, Liège, Belgium
| | | | | | | | | | | |
Collapse
|
342
|
Orloff LA, Domb AJ, Teomim D, Fishbein I, Golomb G. Biodegradable implant strategies for inhibition of restenosis. Adv Drug Deliv Rev 1997. [DOI: 10.1016/s0169-409x(96)00478-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
343
|
Ovünç K, Kabukçu M, Aksöyek S, Kabakci G, Aytemir K, Tokgözoğlu L, Ozmen F, Oto MA. Is there any association between dissection after successful percutaneous transluminal coronary angioplasty and late restenosis? An angiographic study. Angiology 1997; 48:111-6. [PMID: 9040264 DOI: 10.1177/000331979704800202] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Restenosis continues to be the most important limitation of percutaneous transluminal coronary angioplasty (PTCA). Many clinical, angiographic, and procedural variables are thought to be related to the development of restenosis. This study was aimed at investigating the effects of no dissection, minor dissections, and major dissections on the long-term outcome of lesions after successful PTCA. The study group comprised 91 patients with 100 lesions who underwent successful PTCA and in whom follow-up coronary angiography was performed at 8.8 +/- 7.2 (two to twenty-three) months after dilation. Dissections were classified according to the National Heart, Lung, and Blood Institute criteria. Restenosis was defined as more than 50% stenosis at follow-up angiography. Restenosis rates were found to be 22% in the no-dissection group (10 restenoses in 46 patients), 27% in the minor dissection group (11 restenoses in 40 patients), and 36% in the major dissection group (5 restenoses in 14 patients). The authors applied corrected Yates Chi-square test and no difference was observed in the restenosis rate between the group without any dissections and that with minor dissections (P > 0.05). However, a statistically significant difference was observed in the restenosis rate between the major dissection group and the other two groups (P < 0.05). The authors conclude that the occurrence of major dissections after successful PTCA may adversely affect the long-term outcome and may increase the restenosis rate.
Collapse
Affiliation(s)
- K Ovünç
- Department of Cardiology, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | | | | | | | | | | | | | | |
Collapse
|
344
|
TOMARU TAKANOBU, YOSHIMURA ASHIO, AOKI NAOTO, OMATA MASAO, GESCHWIND HERBERTJ, UCHIDA YASUMI. Local Delivery of Antithrombotic Drug Inhibits Neointimal Hyperplasia Following Arterial Injury. J Interv Cardiol 1997. [DOI: 10.1111/j.1540-8183.1997.tb00005.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
345
|
|
346
|
Affiliation(s)
- M K Hong
- Washington Cardiology Center, Washington, DC, USA
| | | | | | | |
Collapse
|
347
|
Coplan NL, Curkovic V, Allen KM, Atallah V. Early exercise testing to stratify risk for development of restenosis after percutaneous transluminal coronary angioplasty. Am Heart J 1996; 132:1222-5. [PMID: 8969574 DOI: 10.1016/s0002-8703(96)90466-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- N L Coplan
- Department of Medicine, Lenox Hill Hospital, New York, NY, USA
| | | | | | | |
Collapse
|
348
|
Hara K, Suma H, Kozuma K, Horii T, Wanibuchi Y, Yamaguchi T, Tamura T. Long-term outcome of percutaneous transluminal coronary angioplasty and coronary bypass surgery for multivessel coronary artery disease. JAPANESE CIRCULATION JOURNAL 1996; 60:940-6. [PMID: 8996684 DOI: 10.1253/jcj.60.940] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We studied the short- and long-term outcomes of 97 patients treated with percutaneous transluminal coronary angioplasty (PTCA) and 72 patients treated with coronary artery bypass graft surgery (CABG) for multivessel coronary artery disease in a single hospital in 1989. Patients treated with CABG had a higher angina class, a higher incidence of diabetes mellitus and a greater extent of the disease. Complete revascularization was achieved in 61 patients (85%) with CABG and in 45 patients (46%) with PTCA (p < 0.001). Initial success of PTCA and CABG was obtained in 95% and 94% of the patients with PTCA and CABG, respectively. Actuarial survival rates at 5 years were similar (96% in the PTCA group; 94% in the CABG group). Fewer patients suffered from cardiac death or myocardial infarction in the CABG group than in the PTCA group, but this difference was not significant. The rate of survival free from death, myocardial infarction, CABG and repeat PTCA, was significantly higher in the CABG group than in the PTCA group (85% vs 48%; p < 0.001). These results suggest that CABG provides a favorable long-term outcome in patients with multivessel coronary artery disease and that PTCA provides a similar outcome in these patients when applied to suitable lesions, although more patients who undergo PTCA require repeat procedures.
Collapse
Affiliation(s)
- K Hara
- Cardiovascular Center, Mitsui Memorial Hospital, Tokyo, Japan
| | | | | | | | | | | | | |
Collapse
|
349
|
Tomaru T, Fujimori Y, Morita T, Aoki N, Sakamoto Y, Nakamura F, Omata M, Uchida Y. Local delivery of antithrombotic drug prevents restenosis after balloon angioplasty in atherosclerotic rabbit artery. JAPANESE CIRCULATION JOURNAL 1996; 60:981-92. [PMID: 8996689 DOI: 10.1253/jcj.60.981] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We investigated the ability of various antithrombotic drugs, delivered locally, to prevent restenosis after angioplasty in hypercholesterolemic rabbits. After dilating atherosclerotic iliac stenoses by balloon angioplasty, a low dose of heparin or a new antithrombotic drug, such as low molecular weight heparin (fragmin), argatroban, or batroxobin, was delivered locally using the balloon double-occlusion technique. In 1 group, high-dose heparin was administered intravenously. Animals that received no drugs served as a control group. After angioplasty, the stenotic segment was dilated and the mean percentage luminal stenosis fell from 89% to 9% in the group that received locally delivered heparin, from 88% to 7% in the group that received locally delivered argatroban, from 87% to 11% in the group that received locally delivered fragmin, from 88% to 15% in the group that received locally delivered batroxobin, from 82% to 18% in the group that received i.v. heparin (p < 0.0001 compared with before angioplasty in each case), and from 84% to 17% in the control group (p < 0.005 compared with before angioplasty). Twenty-eight days after angioplasty, the percentage luminal stenosis remained at 14% in the group that received locally delivered argatroban, 15% in the group that received locally delivered fragmin, and 28% in the group that received locally delivered batroxobin, whereas it increased to 45% in the group that received i.v. heparin, 30% in the group that received locally delivered heparin and 72% in the control group (p < 0.05 compared with after angioplasty in each case). Thus, local delivery low doses of new antithrombotic drugs prevents restenosis after angioplasty without affecting systemic coagulability; heparin, whether administered locally or intravenously, was less effective than the new drugs in preventing restenosis.
Collapse
Affiliation(s)
- T Tomaru
- Second Department of Internal Medicine, University of Tokyo, Japan
| | | | | | | | | | | | | | | |
Collapse
|
350
|
|