1
|
Zandinejad A, Zadeh RS, Khanlar LN, Barmak AB, Revilla-León M. Fracture resistance, marginal and internal adaptation of innovative 3D-printed graded structure crown using a 3D jet printing technology. J Prosthodont 2024; 33:684-690. [PMID: 39118597 DOI: 10.1111/jopr.13895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 05/27/2024] [Indexed: 08/10/2024] Open
Abstract
PURPOSE This in vitro study aimed to create a graded structured dental crown using 3D printing technology and investigate the fracture resistance and the adaptation of this new design. MATERIALS AND METHODS A dental crown with a uniform thickness of 1.5 mm was designed, and the exported stereolithography file (STL) was used to manufacture 30 crowns in three groups (n = 10), solid (SC), bilayer (BL), and multilayer (ML) crowns using 3D jet printing technology. Marginal and internal gaps were measured using the silicone replica technique. Crowns were then luted to a resin die using a temporary luting agent and the fracture resistance was measured using a universal testing machine. One-way ANOVA and Tukey post hoc tests were used to compare the fracture resistance and the adaptation of crowns at a significance level of 0.05. RESULTS Mean marginal and internal gap of the ML group were 80 and 82 mm, respectively; which were significantly (p < 0.05) smaller than BL (203 and 183 mm) and SC (318 and 221 mm) groups. The SC group showed the highest mean load at fracture (2330 N) which was significantly (p < 0.05) higher than the BL (1716 N) and ML (1516 N) groups. CONCLUSION 3D jet printing technology provides an opportunity to manufacture crowns in a graded structure with various mechanical properties. This study provided an example of graded structured crowns and presented their fracture resistance. SC group had the highest fracture resistance; however, ML had the best marginal and internal adaptation.
Collapse
Affiliation(s)
- Amirali Zandinejad
- Implant Dentistry Associates of Arlington, ClearChoice, Arlington, Texas, USA
- School of Medicine and Dentistry, University of Rochester, Rochester, New York, USA
| | - Ramtin Sadid Zadeh
- Department of Restorative Dentistry, School of Dentistry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Leila Nasiry Khanlar
- A.T. Still University-Missouri School of Dentistry & Oral Health, Kirksville, Missouri, USA
| | - Abdul Basir Barmak
- Clinical Research and Biostatistics, School of Medicine and Dentistry, University of Rochester, Rochester, New York, USA
| | - Marta Revilla-León
- Director of Research and Digital Dentistry, Kois Center, Seattle, Washington, USA
| |
Collapse
|
2
|
Chen Y, Bai X, Xu M, Zhou T, Loh YM, Wang C, Pow EHN, Tsoi JKH. The mechanical, wear, antibacterial properties and biocompatibility of injectable restorative materials under wet challenge. J Dent 2024; 146:105025. [PMID: 38697507 DOI: 10.1016/j.jdent.2024.105025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/08/2024] [Accepted: 04/24/2024] [Indexed: 05/05/2024] Open
Abstract
OBJECTIVES To evaluate the mechanical, wear, antibacterial properties, and biocompatibility of injectable composite materials. METHODS Two injectable composite resins (GU and BI), one flowable composite resin (FS), and one flowable compomer (DF), in A2 shade, were tested. Mechanical properties were tested via three-point bending test immediately after preparation and after 1-day, 7-day, 14-day, and 30-day water storage. Under water-PMMA slurry immersion, specimens were subjected to a 3-body wear test (10,000 cycles) against stainless steel balls, while the roughness, wear depth, and volume loss were recorded. After 1-day and 3-day MC3T3-E1 cell culture, cell viability was evaluated with CCK-8 test kits, while the cell morphology was observed under CLSM and SEM. Antibacterial properties on S. mutans were assessed via CFU counting, CLSM, and SEM observation. SPSS 26.0 was used for statistical analysis (α = 0.05). RESULTS The mechanical properties were material-dependent and sensitive to water storage. Flexural strength ranked GU > FS > BI > DF at all testing levels. Three nanocomposites had better wear properties than DF. No significant difference on 1-day cell viability was found, but DF showed significantly lower cell proliferation than nanocomposites on 3-day assessment. GU and FS had more favourable cell adhesion and morphology. CFU counting revealed no significant difference, while FS presented a slightly thicker biofilm and BI showed relatively lower bacteria density. CONCLUSIONS Injectable nanocomposites outperformed the compomer regarding mechanical properties, wear resistance, and biocompatibility. The tested materials presented comparable antibacterial behaviours. Flowable resin-based composites' performances are affected by multiple factors, and their compositions can be attributed. CLINICAL SIGNIFICANCE A profound understanding of the mechanical, wear, and biological properties of the restorative material is imperative for the clinical success of dental restorations. The current study demonstrated superior properties of highly filled injectable composite resins, which imply their wider indications and better long-term clinical performances.
Collapse
Affiliation(s)
- Yanning Chen
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Xuedong Bai
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Mengxiao Xu
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Tianyu Zhou
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Yee Man Loh
- State Key Laboratory of Ultra-precision Machining Technology, Department of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Chunjin Wang
- State Key Laboratory of Ultra-precision Machining Technology, Department of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Edmond Ho Nang Pow
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - James Kit Hon Tsoi
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China.
| |
Collapse
|
3
|
Fouquet V, Larsen N, Stchepinsky AC, Vennat E, Benoit A, Tapie L. A parametrical finite element analysis for functionally graded material overlay restoration. J Mech Behav Biomed Mater 2024; 152:106409. [PMID: 38277910 DOI: 10.1016/j.jmbbm.2024.106409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 01/13/2024] [Accepted: 01/15/2024] [Indexed: 01/28/2024]
Abstract
The main cause of failure in bonded ceramic restorations is material fracture due to excessive stress concentration at the base of the prosthesis. The design of restorative functionally graded materials (FGM) could represent a major advance in dissipating mechanical stresses during occlusal contacts. The aim of this paper is to carry out a complete factorial design of finite element analyses to optimize a multilayer FGM introduced at the bottom of an overlay prosthesis. The number and thickness of layers vary within a spectrum compatible with ceramic shaping processes whereas Young's moduli variations are set in the range of dental tissues. For a 1.5-mm thick prosthesis, the optimal FGM configuration appears to be a 5 layers of 0.2 mm thickness with a linear distribution of Young's modulus from 30 to 70 GPa. This configuration was implemented in a 3D model of a restored tooth with realistic geometry to validate the proof-of-concept.
Collapse
Affiliation(s)
- Vincent Fouquet
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France; Université Sorbonne Paris Nord, F-93430, Villetaneuse, France; AP-HP, Louis-Mourier Hospital, Oral Medecine Department, F-92700, Colombes, France
| | - Nicoline Larsen
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France
| | | | - Elsa Vennat
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France; Université Paris-Saclay, CentraleSupélec, ENS Paris-Saclay, CNRS, LMPS - Laboratoire de Mécanique Paris-Saclay, 91190, Gif sur Yvette, France
| | - Aurélie Benoit
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France.
| | - Laurent Tapie
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France; EPF Engineering School, F-94230, Cachan, France.
| |
Collapse
|
4
|
Najafzadeh A, Hernaiz-García M, Benazzi S, Chen B, Hublin JJ, Kullmer O, Pokhojaev A, Sarig R, Sorrentino R, Vazzana A, Fiorenza L. Finite element analysis of Neanderthal and early Homo sapiens maxillary central incisor. J Hum Evol 2024; 189:103512. [PMID: 38461589 DOI: 10.1016/j.jhevol.2024.103512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 02/12/2024] [Accepted: 02/13/2024] [Indexed: 03/12/2024]
Abstract
Neanderthal anterior teeth are very large and have a distinctive morphology characterized by robust 'shovel-shaped' crowns. These features are frequently seen as adaptive responses in dissipating heavy mechanical loads resulting from masticatory and non-masticatory activities. Although the long-standing debate surrounding this hypothesis has played a central role in paleoanthropology, is still unclear if Neanderthal anterior teeth can resist high mechanical loads or not. A novel way to answer this question is to use a multidisciplinary approach that considers together tooth architecture, dental wear and jaw movements. The aim of this study is to functionally reposition the teeth of Le Moustier 1 (a Neanderthal adolescent) and Qafzeh 9 (an early Homo sapiens adolescent) derived from wear facet mapping, occlusal fingerprint analysis and physical dental restoration methods. The restored dental arches are then used to perform finite element analysis on the left central maxillary incisor during edge-to-edge occlusion. The results show stress distribution differences between Le Moustier 1 and Qafzeh 9, with the former displaying higher tensile stress in enamel around the lingual fossa but lower concentration of stress in the lingual aspect of the root surface. These results seem to suggest that the presence of labial convexity, lingual tubercle and of a large root surface in Le Moustier 1 incisor helps in dissipating mechanical stress. The absence of these dental features in Qafzeh 9 is compensated by the presence of a thicker enamel, which helps in reducing the stress in the tooth crown.
Collapse
Affiliation(s)
- Ali Najafzadeh
- Monash Biomedicine Discovery Institute, Department of Anatomy and Developmental Biology, Monash University, Melbourne, VIC, 3800, Australia; Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, 3800, Australia
| | - María Hernaiz-García
- Monash Biomedicine Discovery Institute, Department of Anatomy and Developmental Biology, Monash University, Melbourne, VIC, 3800, Australia
| | - Stefano Benazzi
- Department of Cultural Heritage, University of Bologna, Ravenna, 48121, Italy
| | - Bernard Chen
- Department of Surgery, The University of Melbourne, Melbourne, VIC, 3010, Australia
| | - Jean-Jacques Hublin
- Chaire de Paléoanthropologie, CIRB (UMR 7241-U1050), Collège de France, 11, Place Marcelin-Berthelot, 75231, Paris, Cedex 05, France; Max Planck Institute for Evolutionary Anthropology, Leipzig, 04103, Germany
| | - Ottmar Kullmer
- Division of Palaeoanthropology, Senckenberg Research Institute and Natural History Museum Frankfurt, Frankfurt a. M, 60325, Germany; Department of Palaeobiology and Environment, Institute of Ecology, Evolution, and Diversity, Goethe University, Frankfurt a. M, 60438, Germany
| | - Ariel Pokhojaev
- Department of Oral Biology, The Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Rachel Sarig
- Department of Oral Biology, The Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, 69978, Israel; Dan David Center for Human Evolution and Biohistory Research, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Rita Sorrentino
- Department of Cultural Heritage, University of Bologna, Ravenna, 48121, Italy; Department of Biological, Geological and Environmental Sciences, University of Bologna, Bologna, 40126, Italy
| | - Antonino Vazzana
- Department of Cultural Heritage, University of Bologna, Ravenna, 48121, Italy
| | - Luca Fiorenza
- Monash Biomedicine Discovery Institute, Department of Anatomy and Developmental Biology, Monash University, Melbourne, VIC, 3800, Australia.
| |
Collapse
|
5
|
Bryniarska-Kubiak N, Basta-Kaim A, Kubiak A. Mechanobiology of Dental Pulp Cells. Cells 2024; 13:375. [PMID: 38474339 DOI: 10.3390/cells13050375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 02/06/2024] [Accepted: 02/11/2024] [Indexed: 03/14/2024] Open
Abstract
The dental pulp is the inner part of the tooth responsible for properly functioning during its lifespan. Apart from the very big biological heterogeneity of dental cells, tooth microenvironments differ a lot in the context of mechanical properties-ranging from 5.5 kPa for dental pulp to around 100 GPa for dentin and enamel. This physical heterogeneity and complexity plays a key role in tooth physiology and in turn, is a great target for a variety of therapeutic approaches. First of all, physical mechanisms are crucial for the pain propagation process from the tooth surface to the nerves inside the dental pulp. On the other hand, the modulation of the physical environment affects the functioning of dental pulp cells and thus is important for regenerative medicine. In the present review, we describe the physiological significance of biomechanical processes in the physiology and pathology of dental pulp. Moreover, we couple those phenomena with recent advances in the fields of bioengineering and pharmacology aiming to control the functioning of dental pulp cells, reduce pain, and enhance the differentiation of dental cells into desired lineages. The reviewed literature shows great progress in the topic of bioengineering of dental pulp-although mainly in vitro. Apart from a few positions, it leaves a gap for necessary filling with studies providing the mechanisms of the mechanical control of dental pulp functioning in vivo.
Collapse
Affiliation(s)
- Natalia Bryniarska-Kubiak
- Laboratory of Immunoendocrinology, Department of Experimental Neuroendocrinology, Maj Institute of Pharmacology, Polish Academy of Sciences, 12 Smętna St., 31-343 Kraków, Poland
- Laboratory of Stem Cell Biology, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, 7 Gronostajowa St., 30-387 Kraków, Poland
| | - Agnieszka Basta-Kaim
- Laboratory of Immunoendocrinology, Department of Experimental Neuroendocrinology, Maj Institute of Pharmacology, Polish Academy of Sciences, 12 Smętna St., 31-343 Kraków, Poland
| | - Andrzej Kubiak
- Laboratory of Stem Cell Biology, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, 7 Gronostajowa St., 30-387 Kraków, Poland
| |
Collapse
|
6
|
Hasegawa M, Tanaka R, Zhong J, Kobayashi M, Manabe A, Shibata Y. Deciphering load attenuation mechanisms of the dentin-enamel junction: Insights from a viscoelastic constitutive model. Acta Biomater 2023; 171:193-201. [PMID: 37669711 DOI: 10.1016/j.actbio.2023.08.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 08/03/2023] [Accepted: 08/24/2023] [Indexed: 09/07/2023]
Abstract
A considerable material discontinuity between the enamel and dentin might jeopardize the tooth's mechanical durability over time without the attenuation of the dentin-enamel junction (DEJ). However, the critical loading transmission mechanism at the DEJ remains understudied. This study aimed to define the extent and effective width of the DEJ, along with its mechanical competence. The presence of DEJ interphase layer was identified using a motif analysis based on the ion beam-transmission electron microscopy coupled with nanoindentation modulus mapping. For each region, nanoindentation load-displacement curves were recorded and mathematically analyzed using an appropriate viscoelastic constitutive model. The time-course of indenter penetration (creep) behavior of the tooth tissues can be mathematically approximated by the Kelvin-Voigt model in series, which determined the visco-contribution to the overall mechanical responses. Therefore, the elastic-plastic contribution can be distinguished from the overall mechanical responses of the tooth after subtracting the visco-contributions. During the loading period, the enamel behavior was dominated by elastic-plastic responses, while both the dentin and DEJ showed pronounced viscoelastic responses. The instantaneous modulus of the DEJ, which was measured by eliminating viscoelastic behavior from the raw load-displacement curve, was almost double that of the dentin. The DEJ was stiffer than the dentin, but it exhibited large viscoelastic motion even at the initial loading stage. This study revealed that the load attenuation competence of the DEJ, which involves extra energy expenditure, is mainly associated with its viscoelasticity. The mathematical analysis proposed here, performed on the nanoindentation creep behavior, could potentially augment the existing knowledge on hard-tissue biomechanics. STATEMENT OF SIGNIFICANCE: In this study, we undertake a rigorous mechanical characterization of the dentin-enamel junction (DEJ) using an advanced nanoindentation technique coupled with a pertinent viscoelastic constitutive model. Our approach unveils the substantial viscoelastic contribution of the DEJ during the initial indentation loading phase and offers an elaborate delineation of the DEJ interphase layer through sophisticated image analysis. These insights significantly augment our understanding of tooth durability. Importantly, our innovative mathematical analysis of creep behavior introduces a novel approach with profound implications for future research in the expansive field of hard-tissue biomechanics. The pioneering methodologies and findings presented in this work hold substantial potential to invigorate progress in biomaterials research and fuel further explorations into the functionality of biological tissues.
Collapse
Affiliation(s)
- Masataka Hasegawa
- Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University Graduate School of Dentistry, 2-1-1 Kitasenzoku, Ohta-ku, Tokyo 145-8515, Japan
| | - Reina Tanaka
- Department of Biomaterials and Engineering, Showa University School of Dentistry, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo 142-8555, Japan.
| | - Jingxiao Zhong
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney NSW, 2006, Australia
| | - Mikihiro Kobayashi
- Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry, 2-1-1 Kitasenzoku, Ohta-ku, Tokyo 145-8515, Japan
| | - Atsufumi Manabe
- Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry, 2-1-1 Kitasenzoku, Ohta-ku, Tokyo 145-8515, Japan
| | - Yo Shibata
- Department of Biomaterials and Engineering, Showa University School of Dentistry, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo 142-8555, Japan
| |
Collapse
|
7
|
Taques LV, Chidoski JC, Ávila BO, Jitumori RT, Gomes JC, Gomes GM. Evaluation of Bond Strength and Fracture Load of Teeth With Flared Root Canals Restored With Prefabricated, Anatomical, and Computer-aided Design and Computer-aided Manufacturing Fiber Posts. Oper Dent 2023; 48:524-537. [PMID: 37635454 DOI: 10.2341/22-083-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2023] [Indexed: 08/29/2023]
Abstract
PURPOSE This study compared the use of anatomical glass fiber posts using bulk-fill composite resin with computer-aided design and computer-aided manufacturing (CAD/CAM) milled glass fiber post in oversized root canals, through bond strength (BS) and fracture resistance (FR) tests (fracture load). METHODS AND MATERIALS A total of 48 mandibular premolars were selected, half of them had their crowns removed at the cemento-enamel junction (CEJ) and the other half were sectioned 2 mm above the CEJ. Subsequently, teeth were endodontically treated. After 1 week, the standard preparation of the canals was carried out, and the roots were divided into three groups (n=16), according to the use of different restorative techniques (control: prefabricated glass fiber post [PFP], direct anatomical glass fiber post [AFP], and CAD/CAM milled glass fiber post [MFP]). After luting procedures using Single Bond Universal and RelyX Ultimate (3M ESPE), for eight teeth in each group, six specimens were obtained (two slices from each root third: cervical, middle, and apical). For the remaining eight roots of each group, standardized preparations for metal-free crowns, milling of 5 mol% yttria-stabilized tetragonal zirconia polycrystalline, cementation of the crowns, and periodontal ligament simulation were performed. Then, for each group, the BS was evaluated through the push-out test, and the FR was evaluated in compression. The data obtained from BS were submitted to two-way analysis of variance (ANOVA; group vs root region) and Tukey (α=0.05) and from FR to one-way ANOVA (group) and Tukey (α=0.05). RESULTS For the BS test, the MFP group was statistically superior to the PFP group in all root regions and was statistically superior to the AFP group only in the cervical region, being statistically similar in the middle and apical root regions. For the FR test, the MFP group was statistically superior to the PFP and AFP groups. CONCLUSION The milled fiber post technique can be a legitimate alternative in the restoration of weakened roots with flared root canals.
Collapse
Affiliation(s)
- L V Taques
- Lucas Vinícius Taques, DDS, MSc, PhD student, Universidade Estadual de Ponta Grossa, Paraná, Brazil
| | - J C Chidoski
- Julio Cezar Chidoski-Filho, DDS, MSc, PhD, Centro Universitário Unifasipe
| | - B O Ávila
- Bianca de Oliveira de Ávila, DDS student, Universidade Estadual de Ponta Grossa, Paraná, Brazil
| | - R T Jitumori
- Renata Terumi Jitumori, DDS, MSc, PhD, Universidade Estadual de Ponta Grossa, Paraná, Brazil
| | - J C Gomes
- João Carlos Gomes, DDS, MSc, PhD, Universidade Estadual de Ponta Grossa, Paraná, Brazil
| | - G M Gomes
- *Giovana Mongruel Gomes, DDS, MSc, PhD, Universidade Estadual de Ponta Grossa, Ponta Grossa, Paraná, Brazil
| |
Collapse
|
8
|
Pragya A, Ghosh TK. Soft Functionally Gradient Materials and Structures - Natural and Manmade: A Review. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023:e2300912. [PMID: 37031358 DOI: 10.1002/adma.202300912] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/31/2023] [Indexed: 06/19/2023]
Abstract
Functionally gradient materials (FGM) have gradual variations in their properties along one or more dimensions due to local compositional or structural distinctions by design. Traditionally, hard materials (e.g., metals, ceramics) are used to design and fabricate FGMs; however, there is increasing interest in polymer-based soft and compliant FGMs mainly because of their potential application in the human environment. Soft FGMs are ideally suitable to manage interfacial problems in dissimilar materials used in many emerging devices and systems for human interaction, such as soft robotics and electronic textiles and beyond. Soft systems are ubiquitous in everyday lives; they are resilient and can easily deform, absorb energy, and adapt to changing environments. Here, the basic design and functional principles of biological FGMs and their manmade counterparts are discussed using representative examples. The remarkable multifunctional properties of natural FGMs resulting from their sophisticated hierarchical structures, built from a relatively limited choice of materials, offer a rich source of new design paradigms and manufacturing strategies for manmade materials and systems for emerging technological needs. Finally, the challenges and potential pathways are highlighted to leverage soft materials' facile processability and unique properties toward functional FGMs.
Collapse
Affiliation(s)
- Akanksha Pragya
- Department of Textile Engineering Chemistry and Science, Fiber, and Polymer Science Program, Wilson College of Textiles, North Carolina State University, North Carolina State University, 1020 Main Campus Drive, Raleigh, NC, 27606, USA
| | - Tushar K Ghosh
- Department of Textile Engineering Chemistry and Science, Fiber, and Polymer Science Program, Wilson College of Textiles, North Carolina State University, North Carolina State University, 1020 Main Campus Drive, Raleigh, NC, 27606, USA
| |
Collapse
|
9
|
Ezenwafor T, Anye V, Madukwe J, Amin S, Obayemi J, Odusanya O, Soboyejo W. Nanoindentation study of the viscoelastic properties of human triple negative breast cancer tissues: Implications for mechanical biomarkers. Acta Biomater 2023; 158:374-392. [PMID: 36640950 DOI: 10.1016/j.actbio.2023.01.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 01/03/2023] [Accepted: 01/05/2023] [Indexed: 01/13/2023]
Abstract
This paper presents the results of a combined experimental and theoretical study of the structure and viscoelastic properties of human non-tumorigenic mammary breast tissues and triple negative breast cancer (TNBC) tissues of different histological grades. A combination of immunofluorescence and confocal microscopy, and atomic force microscopy is used to study the actin cytoskeletal structures of non-tumorigenic and tumorigenic breast tissues (grade I to grade III). A combination of nanoindentation and statistical techniques is then used to measure viscoelastic properties of non-tumorigenic and human TNBC of different histological grades. A Standard Fluid Model/Anti-Zener Model II is also used to characterize the viscoelastic properties of the non-tumorigenic and tumorigenic TNBC tissues of different grades. The implications of the results are discussed for the potential application of nanoindentation and statistical deconvolution techniques to the development of mechanical biomarkers for TNBC detection/cancer diagnosis. STATEMENT OF SIGNIFICANCE: There is increasing interest in the development of mechanical biomarkers for cancer diagnosis. Here, we show that nanoindentation techniques can be used to characterize the viscoelastic properties of normal breast tissue and TNBC tissues of different histological grades. The Standard Fluid Model (Anti-Zener Model II) is used to classify the viscoelastic properties of breast tissues of different TNBC histological grades. Our results suggest that breast tissue and TNBC tissue viscoelastic properties can be used as mechanical biomarkers for the detection of TNBC at different stages.
Collapse
Affiliation(s)
- Theresa Ezenwafor
- Department of Materials Science and Engineering, African University of Science and Technology, Km 10 Airport Road, Galadimawa, Abuja, Federal Capital Territory (FCT), Nigeria; NASENI Centre of Excellence in Nanotechnology and Advanced Materials, Km 4, Ondo Road, Akure, Ondo State, Nigeria; Department of Mechanical and Materials Engineering, Worcester Polytechnic Institute (WPI), 100 Institute Road, Worcester, MA 01609, United States; Department of Biomedical Engineering, Worcester Polytechnic Institute, 60 Prescott Street, Gateway Park Life Sciences and Bioengineering Centre, Worcester, MA 01609, United States
| | - Vitalis Anye
- Department of Materials Science and Engineering, African University of Science and Technology, Km 10 Airport Road, Galadimawa, Abuja, Federal Capital Territory (FCT), Nigeria
| | - Jonathan Madukwe
- Department of Histopathology, National Hospital Abuja, Federal Capital Territory (FCT), Nigeria
| | - Said Amin
- Department of Histopathology, National Hospital Abuja, Federal Capital Territory (FCT), Nigeria
| | - John Obayemi
- Department of Mechanical and Materials Engineering, Worcester Polytechnic Institute (WPI), 100 Institute Road, Worcester, MA 01609, United States; Department of Biomedical Engineering, Worcester Polytechnic Institute, 60 Prescott Street, Gateway Park Life Sciences and Bioengineering Centre, Worcester, MA 01609, United States
| | - Olushola Odusanya
- Department of Materials Science and Engineering, African University of Science and Technology, Km 10 Airport Road, Galadimawa, Abuja, Federal Capital Territory (FCT), Nigeria; Biotechnology and Genetic Engineering Advanced Laboratory, Sheda Science and Technology Complex (SHESTCO), Kwale, Federal Capital Territory, Abuja, Nigeria
| | - Winston Soboyejo
- Department of Materials Science and Engineering, African University of Science and Technology, Km 10 Airport Road, Galadimawa, Abuja, Federal Capital Territory (FCT), Nigeria; Department of Mechanical and Materials Engineering, Worcester Polytechnic Institute (WPI), 100 Institute Road, Worcester, MA 01609, United States; Department of Biomedical Engineering, Worcester Polytechnic Institute, 60 Prescott Street, Gateway Park Life Sciences and Bioengineering Centre, Worcester, MA 01609, United States.
| |
Collapse
|
10
|
PEREIRA RM, RIBAS RG, MONTANHEIRO TLDA, SCHATKOSKI VM, RODRIGUES KF, KITO LT, KOBO LK, CAMPOS TMB, BONFANTE EA, GIERTHMUEHLEN PC, SPITZNAGEL FA, THIM GP. An engineering perspective of ceramics applied in dental reconstructions. J Appl Oral Sci 2023; 31:e20220421. [PMID: 36820784 PMCID: PMC9972857 DOI: 10.1590/1678-7757-2022-0421] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 01/04/2023] [Indexed: 02/22/2023] Open
Abstract
The demands for dental materials continue to grow, driven by the desire to reach a better performance than currently achieved by the available materials. In the dental restorative ceramic field, the structures evolved from the metal-ceramic systems to highly translucent multilayered zirconia, aiming not only for tailored mechanical properties but also for the aesthetics to mimic natural teeth. Ceramics are widely used in prosthetic dentistry due to their attractive clinical properties, including high strength, biocompatibility, chemical stability, and a good combination of optical properties. Metal-ceramics type has always been the golden standard of dental reconstruction. However, this system lacks aesthetic aspects. For this reason, efforts are made to develop materials that met both the mechanical features necessary for the safe performance of the restoration as well as the aesthetic aspects, aiming for a beautiful smile. In this field, glass and high-strength core ceramics have been highly investigated for applications in dental restoration due to their excellent combination of mechanical properties and translucency. However, since these are recent materials when compared with the metal-ceramic system, many studies are still required to guarantee the quality and longevity of these systems. Therefore, a background on available dental materials properties is a starting point to provoke a discussion on the development of potential alternatives to rehabilitate lost hard and soft tissue structures with ceramic-based tooth and implant-supported reconstructions. This review aims to bring the most recent materials research of the two major categories of ceramic restorations: ceramic-metal system and all-ceramic restorations. The practical aspects are herein presented regarding the evolution and development of materials, technologies applications, strength, color, and aesthetics. A trend was observed to use high-strength core ceramics type due to their ability to be manufactured by CAD/CAM technology. In addition, the impacts of COVID-19 on the market of dental restorative ceramics are presented.
Collapse
Affiliation(s)
- Raíssa Monteiro PEREIRA
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| | - Renata Guimarães RIBAS
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| | - Thaís Larissa do Amaral MONTANHEIRO
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| | - Vanessa Modelski SCHATKOSKI
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| | - Karla Faquine RODRIGUES
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| | - Letícia Terumi KITO
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| | - Lucas Kazunori KOBO
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| | - Tiago Moreira Bastos CAMPOS
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| | - Estevam Augusto BONFANTE
- Universidade de São PauloFaculdade de Odontologia de BauruDepartamento de Prótese e PeriodontiaBauruSPBrasilUniversidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Prótese e Periodontia, Bauru, SP, Brasil.
| | - Petra Christine GIERTHMUEHLEN
- Heinrich-Heine-UniversityMedical FacultyUniversity Hospital DüsseldorfDüsseldorfGermanyHeinrich-Heine-University, Medical Faculty and University Hospital Düsseldorf, Düsseldorf, Department of Prosthodontics, Germany.
| | - Frank Akito SPITZNAGEL
- Heinrich-Heine-UniversityMedical FacultyUniversity Hospital DüsseldorfDüsseldorfGermanyHeinrich-Heine-University, Medical Faculty and University Hospital Düsseldorf, Düsseldorf, Department of Prosthodontics, Germany.
| | - Gilmar Patrocínio THIM
- Instituto Tecnológico de AeronáuticaLaboratório de Plasma e ProcessosSão José dos CamposBrasilInstituto Tecnológico de Aeronáutica (ITA), Laboratório de Plasma e Processos (LPP), São José dos Campos, Brasil
| |
Collapse
|
11
|
Kruzic JJ, Hoffman M, Arsecularatne JA. Fatigue and wear of human tooth enamel: A review. J Mech Behav Biomed Mater 2023; 138:105574. [PMID: 36473402 DOI: 10.1016/j.jmbbm.2022.105574] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 09/14/2022] [Accepted: 11/15/2022] [Indexed: 11/21/2022]
Abstract
Human tooth enamel must withstand the cyclic contact forces, wear, and corrosion processes involved with typical oral functions. Furthermore, unlike other human tissues, dental enamel does not have a significant capacity for healing or self-repair and thus the longevity of natural teeth in the oral environment depends to a large degree on the fatigue and wear properties of enamel. The purpose of this review is to provide an overview of our understanding of the fatigue and wear mechanisms of human enamel and how they relate to in vivo observations of tooth damage in the complex oral environment. A key finding of this review is that fatigue and wear processes are closely related. For example, the presence of abrasive wear particles significantly lowers the forces needed to initiate contact fatigue cracking while subsurface fatigue crack propagation drives key delamination wear mechanisms during attrition or attrition-corrosion of enamel. Furthermore, this review seeks to bring a materials science and mechanical engineering perspective to fatigue and wear phenomena. In this regard, we see developing a mechanistic description of fatigue and wear, and understanding the interconnectivity of the processes, as essential for successfully modelling enamel fatigue and wear damage and developing strategies and treatments to improve the longevity of our natural teeth. Furthermore, we anticipate that this review will stimulate ideas for extending the lifetime of the natural tooth structure and will help highlight where our understanding is too limited and where additional research into fatigue and wear of human tooth enamel is warranted.
Collapse
Affiliation(s)
- Jamie J Kruzic
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney NSW 2052, Australia.
| | - Mark Hoffman
- School of Engineering, University of Newcastle, Callaghan NSW 2308, Australia; School of Materials Science and Engineering, University of New South Wales (UNSW Sydney), Sydney NSW 2052, Australia
| | - Joseph A Arsecularatne
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney NSW 2052, Australia
| |
Collapse
|
12
|
Chen Y, Maghami E, Bai X, Huang C, Pow EHN, Tsoi JKH. Which dentine analogue material can replace human dentine for crown fatigue test? Dent Mater 2023; 39:86-100. [PMID: 36503862 DOI: 10.1016/j.dental.2022.11.020] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 11/19/2022] [Accepted: 11/25/2022] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To seek dentine analogue materials in combined experimental, analytical, and numerical approaches on the mechanical properties and fatigue behaviours that could replace human dentine in a crown fatigue laboratory test. METHODS A woven glass fibre-filled epoxy (NEMA grade G10; G10) and a glass fibre-reinforced polyamide-nylon (30% glass fibre reinforced polyamide-nylon 6,6; RPN) were investigated and compared with human dentine (HD). Flexural strength and elastic modulus (n = 10) were tested on beam-shaped specimens via three-point bending, while indentation hardness (n = 3) was tested after fracture. Abutment substrates of G10, RPN and HD were prepared and resin-bonded with monolithic lithium disilicate crowns (n = 10), then subjected to wet cyclic loading in a step-stress manner (500 N initial load, 100 N step size, 100,000 cycles per step, 20 Hz frequency). Data were statistically analysed using Kruskal-Wallis one-way ANOVA followed by post-hoc comparisons (α = 0.05). Survival probability estimation was performed by Mantel-Cox Log-Rank test with 95% confidence intervals. The fatigue failure load (FFL) and the number of cycles until failure (NCF) were evaluated with Weibull statistics. Finite Element Models of the fatigue test were established for stress distribution analysis and lifetime prediction. Fractographic observations were qualitatively analysed. RESULTS The flexural strength of HD (164.27 ± 14.24 MPa), G10 (116.48 ± 5.93 MPa), and RPN (86.73 ± 3.56 MPa) were significantly different (p < 0.001), while no significant difference was observed in their flexural moduli (p = 0.377) and the indentation hardness between HD and RPN (p = 0.749). The wet cyclic fatigue test revealed comparable mean FFL and NCF of G10 and RPN to HD (p = 0.237 and 0.294, respectively) and similar survival probabilities for the three groups (p = 0.055). However, RPN promotes higher stability and lower deviation of fatigue test results than G10 in Weibull analysis and FEA. SIGNIFICANCE Even though dentine analogue materials might exhibit similar elastic properties and fatigue performance to human dentine, different reliabilities of fatigue on crown-dentine analogues were shown. RPN seems to be a better substrate that could provide higher reliability and predictability of laboratory study results.
Collapse
Affiliation(s)
- Yanning Chen
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China
| | - Ebrahim Maghami
- Department of Mechanical Engineering and Mechanics, College of Engineering, Drexel University, Philadelphia, PA 19104, USA
| | - Xuedong Bai
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China
| | - Cui Huang
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory for Oral Biomedicine Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Edmond Ho Nang Pow
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China
| | - James Kit Hon Tsoi
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China.
| |
Collapse
|
13
|
Chiu CT, Cao JK, Wang PW, Wu YN, Lee YC, Jeng YR, Shieh DB, Reisz RR. Mammalian tooth enamel functional sophistication demonstrated by combined nanotribology and synchrotron radiation FTIR analyses. iScience 2022; 26:105679. [PMID: 36713260 PMCID: PMC9881047 DOI: 10.1016/j.isci.2022.105679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 09/28/2022] [Accepted: 11/22/2022] [Indexed: 12/28/2022] Open
Abstract
The teeth of limbed vertebrates used for capturing and processing food are composed of mineralized dentine covered by hypermineralized enamel, the hardest material organisms produce. Here, we combine scanning probe microscopy, depth sensing, and spectromicroscopy (SR-FTIR) to characterize the surface ultrastructural topography, nanotribology, and chemical compositions of mammal species with different dietary habits, including omnivorous humans. Our synergistic approach shows that enamel with greater surface hardness or thickness exhibited a more salient gradient feature from the tooth surface to the dentino-enamel junction (DEJ) one that corresponds to the in situ phosphate-to-amide ratio. This gradient feature of enamel covering softer dentine is the determining factor of the amazingly robust physical property of this unique biomaterial. It provides the ability to dissipate stress under loading and prevent mechanical failure. Evolutionary change in the biochemical composition and biomechanical properties of mammalian dentition is related to variations in the oral processing of different food materials.
Collapse
Affiliation(s)
- Chen-Tzu Chiu
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan 701401, Taiwan
| | - Jyun-Kai Cao
- Department of Mechanical Engineering, National Chung Cheng University, Chia-Yi 62100, Taiwan
| | - Pei-Wen Wang
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan 701401, Taiwan,Center of Applied Nanomedicine and Core Facility Center, National Cheng Kung University, Tainan 701401, Taiwan
| | - Ya-Na Wu
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan 701401, Taiwan,iMANI Center of the National Core Facility for Biopharmaceuticals, National Science and Technology Concil, Taipei 106214, Taiwan
| | - Yao-Chang Lee
- Life Science Group, National Synchrotron Radiation Center, Hsinchu 30076, Taiwan,Department of Optics and Photonics, National Central University, Chung-Li 32001, Taiwan,Department of Chemistry, National Tsing Hua University, Hsinchu 30013, Taiwan
| | - Yeau-Ren Jeng
- Department of Mechanical Engineering, National Chung Cheng University, Chia-Yi 62100, Taiwan,Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan,Medical Device Innovation Center, National Cheng Kung University, Tainan 70101, Taiwan,Academy of Innovative Semiconductor and Sustainable Manufacturing, National Cheng Kung University, Tainan 70101, Taiwan,Corresponding author
| | - Dar-Bin Shieh
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan 701401, Taiwan,Center of Applied Nanomedicine and Core Facility Center, National Cheng Kung University, Tainan 701401, Taiwan,iMANI Center of the National Core Facility for Biopharmaceuticals, National Science and Technology Concil, Taipei 106214, Taiwan,Department of Stomatology, National Cheng Kung University Hospital, Tainan 704302, Taiwan,Corresponding author
| | - Robert R. Reisz
- International Centre of Future Science, Dinosaur Evolution Research Center, Jilin University, Changchun, Jilin 130012, China,Department of Biology, University of Toronto Mississauga, Mississauga, ON, Canada,Corresponding author
| |
Collapse
|
14
|
Chen Y, Wu R, Shen L, Yang Y, Wang G, Yang B. The multi-scale meso-mechanics model of viscoelastic dentin. J Mech Behav Biomed Mater 2022; 136:105525. [PMID: 36302275 DOI: 10.1016/j.jmbbm.2022.105525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Revised: 10/07/2022] [Accepted: 10/13/2022] [Indexed: 11/06/2022]
Abstract
Human dentin is a hierarchical material with multi-level micro-/nano-structures, consisting of tubule, perti-tubular dentin (PTD) and intertubular dentin (ITD) as the major constituents at microscale; and the PTD and ITD are further composed of collagen and hydroxyapatite (HAp) crystals with different volume fractions at nanoscale. In most cases, the HAp is considered as elastic while the collagen as viscoelastic material. It is of great significance to study the hierarchical structure and viscoelasticity of human dentin to understand the mechanical properties of dentin for further development of restorative materials. Based on this, this paper focuses on multiscale modeling of the elastic properties and dynamic viscoelastic response of dentin and establishes a bottom-up micromechanics model from nano-to macro-scale. In order to study the nanostructural effect on the viscoelastic behavior of hierarchical structures, the homogenization theories of random platelets composites (HTRPC) and the locally-exact homogenization theory (LEHT) are introduced for the homogenization of heterogeneous materials of microstructures at different levels. The HTRPC, based on Eshelby Inclusion theory, is used to predict the effective modulus of PTD and ITD. The LEHT is a method for homogenizing multiphase dentin characterized by repeated unit cells (RUCs). The resulting predictions are in very good agreement with several experimental data from the literature. In addition, the results of nanostructrual effect on dentin show that the viscoelasticity of dentin is majorly contributed by collagen and the HAp greatly provide the strength and hardness of dentin. Furthermore, the ageing effect on dentin's viscoelasticity is considered from the proposed multiscale micromechanics model. It is demonstrated that the ageing effect is much more influential in affecting the loss moduli of dentin than the storage.
Collapse
Affiliation(s)
- Yusen Chen
- Department of Civil Engineering, Zhejiang Sci-Tech University, Hangzhou, 310018, China
| | - Rui Wu
- Department of Civil Engineering, Zhejiang University, 866 Yuhangtang Road, Hangzhou, 310058, China; Center for Balance Architecture, Zhejiang University, Hangzhou, 310007, China
| | - Lulu Shen
- Department of Civil Engineering, Zhejiang Sci-Tech University, Hangzhou, 310018, China
| | - Yabin Yang
- School of Materials Science and Engineering, Sun Yat-sen University, Guangzhou, 510275, China
| | - Guannan Wang
- Department of Civil Engineering, Zhejiang University, 866 Yuhangtang Road, Hangzhou, 310058, China; Center for Balance Architecture, Zhejiang University, Hangzhou, 310007, China.
| | - Bo Yang
- Department of Civil Engineering, Zhejiang Sci-Tech University, Hangzhou, 310018, China.
| |
Collapse
|
15
|
Mechanical Properties and In Vitro Biocompatibility of Hybrid Polymer-HA/BAG Ceramic Dental Materials. Polymers (Basel) 2022; 14:polym14183774. [PMID: 36145918 PMCID: PMC9505225 DOI: 10.3390/polym14183774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 09/02/2022] [Accepted: 09/07/2022] [Indexed: 11/16/2022] Open
Abstract
The aim of this study is to prepare hybrid polymer-ceramic dental materials for chairside computer-aided design/computer-aided manufacturing (CAD/CAM) applications. The hybrid polymer-ceramic materials were fabricated via infiltrating polymerizable monomer mixtures into sintered hydroxyapatite/bioactive glass (HA/BAG) ceramic blocks and thermo-curing. The microstructure was observed by scanning electron microscopy and an energy-dispersive spectrometer. The phase structure was analyzed by X-ray diffraction. The composition ratio was analyzed by a thermogravimetric analyzer. The hardness was measured by a Vickers hardness tester. The flexural strength, flexural modulus, and compressive strength were measured and calculated by a universal testing machine. The growth of human gingival fibroblasts was evaluated by a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) colorimetric assay and immunofluorescence staining. The results showed that the sintering temperature and BAG content affected the mechanical properties of the hybrid polymer-ceramic materials. The X-ray diffraction analysis showed that high-temperature sintering promoted the partial conversion of HA to β-tricalcium phosphate. The values of the hardness, flexural strength, flexural modulus, and compressive strength of all the hybrid polymer-ceramic materials were 0.89-3.51 GPa, 57.61-118.05 MPa, 20.26-39.77 GPa, and 60.36-390.46 MPa, respectively. The mechanical properties of the hybrid polymer-ceramic materials were similar to natural teeth. As a trade-off between flexural strength and hardness, hybrid polymer-ceramic material with 20 wt.% BAG sintered at 1000 °C was the best material. In vitro experiments confirmed the biocompatibility of the hybrid polymer-ceramic material. Therefore, the hybrid polymer-ceramic material is expected to become a new type of dental restoration material.
Collapse
|
16
|
Zhu X, Wang S, Ye J, Guo H, Wang R. Investigation of fracture-resistance of human teeth at the dentin-enamel junction using the J-integral calculation of finite element analysis. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422500695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
17
|
House KL, Pan L, O'Carroll DM, Xu S. Applications of scanning electron microscopy and focused ion beam milling in dental research. Eur J Oral Sci 2022; 130:e12853. [PMID: 35288994 DOI: 10.1111/eos.12853] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 01/06/2022] [Indexed: 12/15/2022]
Abstract
The abilities of scanning electron microscopy (SEM) and focused ion beam (FIB) milling for obtaining high-resolution images from top surfaces, cross-sectional surfaces, and even in three dimensions, are becoming increasingly important for imaging and analyzing tooth structures such as enamel and dentin. FIB was originally developed for material research in the semiconductor industry. However, use of SEM/FIB has been growing recently in dental research due to the versatility of dual platform instruments that can be used as a milling device to obtain low-artifact cross-sections of samples combined with high-resolution images. The advent of the SEM/FIB system and accessories may offer access to previously inaccessible length scales for characterizing tooth structures for dental research, opening exciting opportunities to address many central questions in dental research. New discoveries and fundamental breakthroughs in understanding are likely to follow. This review covers the applications, key findings, and future direction of SEM/FIB in dental research in morphology imaging, specimen preparation for transmission electron microscopy (TEM) analysis, and three-dimensional volume imaging using SEM/FIB tomography.
Collapse
Affiliation(s)
- Krystal L House
- Colgate Palmolive Company, Piscataway, New Jersey, USA.,Department of Chemistry and Chemical Biology, Rutgers University, Piscataway, New Jersey, USA
| | - Long Pan
- Colgate Palmolive Company, Piscataway, New Jersey, USA
| | - Deirdre M O'Carroll
- Department of Chemistry and Chemical Biology, Rutgers University, Piscataway, New Jersey, USA.,Department of Materials Science and Engineering, Department of Chemistry and Chemical Biology, Rutgers University, Piscataway, New Jersey, USA
| | - Shiyou Xu
- Colgate Palmolive Company, Piscataway, New Jersey, USA
| |
Collapse
|
18
|
Gorb SN, Krings W. Mechanical property gradients of taenioglossan radular teeth are associated with specific function and ecological niche in Paludomidae (Gastropoda: Mollusca). Acta Biomater 2021; 134:513-530. [PMID: 34329785 DOI: 10.1016/j.actbio.2021.07.057] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 07/16/2021] [Accepted: 07/22/2021] [Indexed: 02/07/2023]
Abstract
Biological tissues may exhibit graded heterogeneities in structure and mechanical properties that are crucial to their function. One biological structure that shows variation in both structure and function is the molluscan radula: the organ comprises a chitinous membrane with embedded teeth and serves to process and gather food. The tooth morphologies had been well studied in the last decades, but the mechanical properties of the teeth are not known for the vast majority of molluscs. This knowledge gap restricts our understanding of how the radula is able to act effectively on a target surface whilst simultaneously resisting structural failure. Here we employed nanoindentation technique to measure mechanical properties (hardness and Young's modulus) on distinct localities of individual radular teeth from 24 species of African paludomid gastropods. These species have distinct ecological niches as they forage on algae on different feeding substrates. A gradual distribution of measured properties along the teeth was found in species foraging on solid or mixed feeding substrates, but soft substrate feeders exhibit teeth almost homogeneous in their biomechanical properties. The presence or absence of large-scale gradients in these taenioglossan teeth could directly be linked with their specific function and in general with the species ecology, whereas the radular tooth morphologies do not always and fully reflect ecology. STATEMENT OF SIGNIFICANCE: African Lake Tanganyika is well known for harbouring endemic and morphologically distinct genera. Its paludomid gastropods form a flock of high interest because of its diversity. As they show distinct radular tooth morphologies hypotheses about potential trophic specializations had always been at hand. Here we evaluated the mechanical properties Young's modulus and hardness of 9027 individual teeth from 24 species along the tooth by nanoindentation and related them with the gastropods' specific feeding substrate. We find that hard substrate feeders have teeth that are hard at the tips but much less stiff at the base and thus heterogeneous with respect to material properties, whereas soft substrate feeders have teeth that are flexible and homogenous with respect to material properties.
Collapse
|
19
|
Zandinejad A, Revilla-León M, Methani MM, Nasiry Khanlar L, Morton D. The Fracture Resistance of Additively Manufactured Monolithic Zirconia vs. Bi-Layered Alumina Toughened Zirconia Crowns When Cemented to Zirconia Abutments. Evaluating the Potential of 3D Printing of Ceramic Crowns: An In Vitro Study. Dent J (Basel) 2021; 9:115. [PMID: 34677177 PMCID: PMC8535066 DOI: 10.3390/dj9100115] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 09/10/2021] [Accepted: 09/24/2021] [Indexed: 11/25/2022] Open
Abstract
(1) Background: This study compared the fracture resistance of additively manufactured monolithic zirconia and bi-layered alumina toughened zirconia crowns on implants. (2) Methods: Maxillary model with a dental implant replacing right second bicuspid was obtained. Custom abutments and full-contour crowns for additively manufactured monolithic zirconia and bi-layered alumina reinforced zirconia crowns (n = 10) were fabricated. The crowns were cemented to implant-supported zirconia abutments and the assembly fixed onto resin blocks. Fracture resistance was measured using a universal testing machine at a crosshead speed of 2 mm/min. A Kruskal-Wallis test was used to analyze the data. (3) Results: Although additively manufactured monolithic zirconia crowns demonstrated a higher mean fracture resistance than bi-layered alumina toughened zirconia crowns, statistical analysis revealed no significant difference in fracture resistance between the two groups. All specimens fractured at the implant-abutment interface. (4) Conclusions: Additively manufactured bi-layered alumina toughened zirconia crowns demonstrated similar fracture resistance to additively manufactured monolithic zirconia crowns when cemented to implant-supported zirconia abutments.
Collapse
Affiliation(s)
- Amirali Zandinejad
- Department of Comprehensive Dentistry, College of Dentistry, Texas A&M University, Dallas, TX 75246, USA;
| | - Marta Revilla-León
- Department of Comprehensive Dentistry, College of Dentistry, Texas A&M University, Dallas, TX 75246, USA;
| | - Mohammad Mujtaba Methani
- Department of Biomedical Sciences, College of Dentistry, Texas A&M University, Dallas, TX 75246, USA;
| | - Leila Nasiry Khanlar
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Bunkyo-ku Yushima, Tokyo 113-8510, Japan;
| | - Dean Morton
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN 46202, USA;
| |
Collapse
|
20
|
Zandinejad A, Das O, Barmak AB, Kuttolamadom M, Revilla-León M. The Flexural Strength and Flexural Modulus of Stereolithography Additively Manufactured Zirconia with Different Porosities. J Prosthodont 2021; 31:434-440. [PMID: 34580962 DOI: 10.1111/jopr.13430] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/01/2021] [Accepted: 09/09/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE Additive manufacturing (AM) technologies are capable of fabricating complex geometries with different porosities. However, the effect of such porosities on mechanical properties of stereolithography (SLA) AM zirconia with different porosities is unclear. The purpose of this in vitro study was to investigate the mechanical properties namely flexural strength, and flexural modulus of AM zirconia with different porosities. MATERIALS AND METHODS A bar (25 × 4 × 3 mm) for flexural strength test (ISO standard 6872/2015) was designed by CAD software program and standard tessellation language (STL) file was obtained. The STL file was used to fabricate a total of 80 bars in four groups. Three experimental groups each containing 20 samples were manufactured using an SLA ceramic printer (CeraMaker 900; 3DCeram Co) and zirconia material (3DMix ZrO2 paste; 3DCeram Co) with different sintering post processing to achieve different porosities including 0%-porosity (AMZ0), 20%-porosity (AMZ20), and 40%-porosity (AMZ40). The same STL file was used for subtractive manufacturing or milling of 20 zirconia bars as control group (CNCZ) with the same dimensions using a commercial zirconia. Three-point bending tests were performed for all groups following ISO standard 6872/2015 specification using a universal testing machine. Outcomes measured included load at fracture, mean flexural strength, and flexural modulus and they were compared across the experimental groups using a one-way ANOVA. Post hoc pair wise comparison between each pair of the groups were performed using Tukey test. RESULTS There was a significant difference between the four groups, in terms of fracture load, flexural strength and flexural modulus using one-way ANOVA. AM zirconia with 0% porosity (AMZ0) showed the highest value for fracture load (1132.7 ± 220.6 N), flexural strength (755.1 ± 147.1 MPa) and flexural modulus (41,273 ± 2193 MPa) and AM zirconia with 40% porosity (AMZ40) showed the lowest fracture load (72.13 ± 13.42 N), flexural strength (48.09 ± 8.95 MPa) and flexural modulus (7177 ± 506 MPa). Tukey's pairwise comparisons detected a significant difference between all the possible pairs for all variables except flexural modulus between AMZ0 and CNCZ. The Weibull moduli presented the lowest value for AMZ20 (4.4) followed by AMZ40 (6.1), AMZ0 (6.1), and the highest value was for CNCZ (8.1). CONCLUSION AM zirconia with 0% porosity showed significantly higher flexural strength and flexural modulus when compared to milled and AM zirconia with 20% and 40% porosities.
Collapse
Affiliation(s)
| | - Omprakash Das
- College of Engineering, Texas A&M University, College Station, TX
| | | | | | - Marta Revilla-León
- College of Dentistry, Texas A&M University, Dallas, TX.,School of Dentistry, University of Washington, Seattle, WA.,Revilla Research Center, Madrid, Spain
| |
Collapse
|
21
|
Desoutter A, Slimani A, Tassery H, Cuisinier F, Sauro S, Salehi H, Panayotov I. Confocal Raman data analysis of tufts and spindles at the human dentin-enamel junction. Arch Oral Biol 2021; 131:105262. [PMID: 34543810 DOI: 10.1016/j.archoralbio.2021.105262] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 09/07/2021] [Accepted: 09/08/2021] [Indexed: 11/17/2022]
Abstract
OBJECTIVE The aim of this article is to analyze the chemical mapping of tufts and spindles of the human dental enamel using confocal Raman microscopy measuring length, structuration and composition of spindles and tufts. DESIGN we used Raman diffusion, based on the interaction between photons and optic phonons, to reveal chemical bound. Adult molars were selected and longitudinally sectioned. Areas of 120 * 120 μm were scanned near the dentin-enamel junction and grooves. Spectra were collected and phosphate and proteins peak intensities images were reconstructed, related to HPA concentration. Images of Phosphate (PO43-, 960 cm-1) and protein (CH, 2800/3000 cm-1) intensities have been reconstructed. K-mean cluster has been calculated to compare centroid spectra from enamel, dentin and tuft or spindle. RESULTS intensity profile revealed spindles as less mineralized areas than enamel, from 5 to 10 µm large. In the groove of molar, long tufts were found, more than 150 µm. CONCLUSIONS Confocal Raman microscopy is a very interesting tool to characterize chemically secondary structure of enamel. The size of a tuft in the groove allows us make the hypothesis that they could play a role in long term resilience of mechanical stress.
Collapse
Affiliation(s)
| | | | - Hervé Tassery
- LBN, Univ Montpellier, Montpellier, France; Université d'Aix-Marseille, Marseille, France
| | | | - Salavatore Sauro
- Dental Biomaterials and Minimally Invasive Dentistry, Department of Dentistry, Cardenal Herrera-CEU University, CEU Universities, C/Santiago Ramón y Cajal, s/n., Alfara del Patriarca, 46115 Valencia, Spain
| | | | | |
Collapse
|
22
|
Bromage TG. The oronasopharyngeal space and renewed formalization of the functional matrix hypothesis. Cranio 2021; 39:275-277. [PMID: 34264168 DOI: 10.1080/08869634.2021.1934779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Timothy G Bromage
- Department of Molecular Pathobiology, New York University College of Dentistry, New York, NY, USA
| |
Collapse
|
23
|
Novel Approach to Tooth Chemistry. Quantification of the Dental-Enamel Junction. Int J Mol Sci 2021; 22:ijms22116003. [PMID: 34199407 PMCID: PMC8199634 DOI: 10.3390/ijms22116003] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 05/26/2021] [Accepted: 05/28/2021] [Indexed: 01/02/2023] Open
Abstract
The dentin-enamel junction (DEJ) is known for its special role in teeth. Several techniques were applied for the investigation of the DEJ in human sound molar teeth. The electron (EPMA) and proton (PIXE) microprobes gave consistent indications about the variability of elemental concentrations on this boundary. The locally increased and oscillating concentrations of Mg and Na were observed in the junction, in the layer adhering to the enamel and covering roughly half of the DEJ width. The chemical results were compared with the optical profiles of the junction. Our chemical and optical results were next compared with the micromechanical results (hardness, elastic modulus, friction coefficient) available in the world literature. A strong correlation of both result sets was proven, which testifies to the self-affinity of the junction structures for different locations and even for different kinds of teeth and techniques applied for studies. Energetic changes in tooth strictly connected with crystallographic transformations were calculated, and the minimum energetic status was discovered for DEJ zone. Modeling of both walls of the DEJ from optical data was demonstrated. Comparing the DEJ in human teeth with the same structure found in dinosaur, shark, and alligator teeth evidences the universality of dentin enamel junction in animal world. The paper makes a contribution to better understanding the joining of the different hard tissues.
Collapse
|
24
|
Ramos GF, Ramos NC, Alves LMM, Kaizer MR, Borges ALS, Campos TMB, Melo RM. Failure probability and stress distribution of milled porcelain-zirconia crowns with bioinspired/traditional design and graded interface. J Mech Behav Biomed Mater 2021; 119:104438. [PMID: 33798936 DOI: 10.1016/j.jmbbm.2021.104438] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 09/14/2020] [Accepted: 02/26/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To evaluate the failure probability and stress distribution of traditional and bioinspired porcelain-zirconia milled crowns, with and without silica infiltration (graded zirconia). METHODS Traditional crown design had a zirconia infrastructure veneered with porcelain; Bioinspired, had a porcelain infrastructure with translucent-zirconia veneer; Graded and Graded Bioinspired crowns had their zirconia layer infiltrated by silica (n = 25). The cameo surface of each crown (porcelain or zirconia) was glazed. The restoration layers were fused by a vitreous connector and the crowns were adhesively cemented to dies. The specimens were then mechanically cycled in a sliding machine using 100 N load at 4 Hz. The specimens were tested until 2 × 106 cycles, and every 0.5 × 106 cycles the crowns were evaluated under stereomicroscopy for the presence of failures. The stress distribution was inspected with Finite Element Analyses. RESULTS The predominant failure modes for the Traditional and Graded crowns were delamination and cracking, respectively. The Weibull parameters beta and eta were, respectively: Traditional 1.30 and 2.3 × 106 cycles, and Graded 1.95 and 2.3 × 106 cycles. Thus, the Traditional and Graded crowns presented greater susceptibility to failure due to fatigue, while the Bioinspired and Graded Bioinspired crowns showed no fatigue effect using 100N load, showing beta = 1 and eta of approximately 17 × 106 cycles. Also, through finite element analyses, it was verified that the Bioinspired and Graded Bioinspired crowns presented the best stress distribution on both crowns and dental structures. SIGNIFICANCE Bioinspired and Graded Bioinspired crowns had the lowest failure probability and better stress distribution and may be considered robust long lasting restorations.
Collapse
Affiliation(s)
- G F Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - N C Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil; College of Dentistry, Sao Francisco University (USF), 218 Sao Francisco de Assis Avenue, 12916-900, Bragança Paulista, SP, Brazil.
| | - L M M Alves
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - M R Kaizer
- College of Dentistry, Positivo University (UP), 5300 Prof. Pedro Viriato Parigot de Souza Street, 81280-330, Curitiba, PR, Brazil.
| | - A L S Borges
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| | - T M B Campos
- Physics Department, Technological Institute of Aeronatics (ITA), 50 Praça Marechal Eduardo Gomes, 12228-900, São José Dos Campos, SP, Brazil.
| | - R M Melo
- Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), Institute of Science and Technology, 777 Eng. Francisco José Longo Avenue, 12245-000, São José Dos Campos, SP, Brazil.
| |
Collapse
|
25
|
Ma Z, Qiang Z, Zeng K, Xiao J, Zhou L, Zu L, Zhao H, Ren L. Prediction of cross section fracture path of cortical bone through nanoindentation array. J Mech Behav Biomed Mater 2021; 116:104303. [PMID: 33497960 DOI: 10.1016/j.jmbbm.2020.104303] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 08/17/2020] [Accepted: 12/29/2020] [Indexed: 11/26/2022]
Abstract
Although great progresses in the fracture mechanisms and deformation behaviors of cortical bones have been achieved, the effective methods to predict the surface fracture path of cortical bones are still difficult. By using depth-sensing nanoindentation measurement technique, the hardness distribution map of cortical bones was obtained through nanoindentation array. Combined with the compressive tests under approximate in vivo environment and micro computed tomography (CT) analysis, the correlation between hardness distribution map and compressive fracture path on the cross section of cortical bone was established. Through extracting the high hardness regions from the hardness distribution map and connecting the high hardness regions combined with the minimum directional derivative principle, the fracture path on cross section under compressive stress was accurately predicted. The feasibility of the prediction method was verified through the comparison between the fitted and actual fracture paths of specimens with sampling orientations of 90° and 45°. The relation between the regions where the fracture propagation path passed through and distribution of Haversian canals were also analyzed.
Collapse
Affiliation(s)
- Zhichao Ma
- School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, China; Key Laboratory of Bionic Engineering Ministry of Education, Jilin University, Changchun, 130025, China
| | - Zhenfeng Qiang
- School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, China; Key Laboratory of CNC Equipment Reliability Ministry of Education, Jilin University, Changchun, 130025, China
| | - Kaiyang Zeng
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore
| | - Jianlin Xiao
- Department of Orthopedics, China-Japan Union Hospital of Jilin University, Changchun, 130033, China
| | - Liming Zhou
- School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, China; Key Laboratory of CNC Equipment Reliability Ministry of Education, Jilin University, Changchun, 130025, China.
| | - Lihui Zu
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, 130033, China
| | - Hongwei Zhao
- School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, China
| | - Luquan Ren
- Key Laboratory of Bionic Engineering Ministry of Education, Jilin University, Changchun, 130025, China
| |
Collapse
|
26
|
Karali A, Kao AP, Zekonyte J, Blunn G, Tozzi G. Micromechanical evaluation of cortical bone using in situ XCT indentation and digital volume correlation. J Mech Behav Biomed Mater 2021; 115:104298. [PMID: 33445104 DOI: 10.1016/j.jmbbm.2020.104298] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 12/22/2020] [Accepted: 12/25/2020] [Indexed: 11/29/2022]
Abstract
The overall mechanical behaviour of cortical bone is strongly dependant on its microstructure. X-ray computed tomography (XCT) has been widely used to identify the microstructural morphology of cortical tissue (i.e. pore network, Haversian and Volkmann's canals). However, the connection between microstructure and mechanics of cortical bone during plastic deformation is unclear. Hence, the purpose of this study is to provide an in-depth evaluation of the interplay of plastic strain building up in relation to changes in the canal network for cortical bone tissue. In situ step-wise XCT indentation was used to introduce a localised load on the surface of the tissue and digital volume correlation (DVC) was employed to assess the three-dimensional (3D) full-field plastic strain distribution in proximity of the indent. It was observed that regions adjacent to the imprint were under tensile strain, whereas the volume underneath experienced compressive strain. Canal loss and disruption was detected in regions of higher compressive strains exceeding -20000 με and crack formation occurred in specimens where Haversian canals were running parallel to the indentation tip. The results of this study outline the relationship between the micromechanical and structural behaviour of cortical bone during plastic deformation, providing information on cortical tissue fracture pathways.
Collapse
Affiliation(s)
- Aikaterina Karali
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK.
| | | | - Jurgita Zekonyte
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK
| | - Gordon Blunn
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, UK.
| | - Gianluca Tozzi
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK.
| |
Collapse
|
27
|
Yoshihara K, Nagaoka N, Nakamura A, Hara T, Yoshida Y, Van Meerbeek B. Nano-Layering Adds Strength to the Adhesive Interface. J Dent Res 2020; 100:515-521. [PMID: 33345712 DOI: 10.1177/0022034520979133] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
X-ray diffraction (XRD) surface analysis and ultrastructural interfacial characterization using transmission electron microscopy (TEM) confirmed that the functional monomer 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) self-assembles into nano-layers at adhesive-tooth interfaces. Self-assembled nano-layering is thought to contribute to the durability of bonding to tooth dentin, although this has not been proven yet. In order to disclose this potential bond-durability contribution of nano-layering, we observed the 3-dimensional (3D) spreading of nano-layering by a series of focused-ion-beam (FIB) milled cross sections by scanning electron microscopy (FIB-SEM) and examined the mechanical properties of self-assembled nano-layering using scanning probe microscopy (SPM). A commercial 10-MDP-containing 3-step self-etch adhesive partially demineralized dentin up to submicron depth, forming a submicron hydroxyapatite-rich hybrid layer. TEM chemically and ultrastructurally confirmed the formation of interfacial nano-layering. FIB-SEM 3D reconstructions disclosed a 3D network of self-assembled nano-layering extending from the hybrid layer up to within the adjacent adhesive-resin layer. SPM revealed that nano-layering within the adhesive-resin layer possessed a higher elastic modulus than that of the surrounding adhesive resin, hereby suggesting that nano-layering contributes to the mechanical strength of adhesives like filler particles do. Nano-layering's 3D expanded structure is expected to strengthen the surrounding resin, as well to better interconnect the adhesive-resin layer to the hybrid layer. In conclusion, this exploratory study demonstrated that nano-layering constitutes a strong phase at the adhesive interface, which may contribute to the clinical longevity of the 10-MDP-based bond to dentin.
Collapse
Affiliation(s)
- K Yoshihara
- National Institute of Advanced Industrial Science and Technology (AIST), Health and Medical Research Institute, Takamatsu, Japan.,Okayama University, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Department of Pathology & Experimental Medicine, Okayama, Japan
| | - N Nagaoka
- Okayama University Dental School, Advanced Research Center for Oral and Craniofacial Sciences, Okayama, Japan
| | - A Nakamura
- National Institute for Materials Science (NIMS), Electron Microscopy Analysis Station, Ibaraki, Japan
| | - T Hara
- National Institute for Materials Science (NIMS), Electron Microscopy Analysis Station, Ibaraki, Japan
| | - Y Yoshida
- Hokkaido University, Faculty of Dental Medicine, Department of Biomaterials and Bioengineering, Sapporo, Hokkaido, Japan
| | - B Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| |
Collapse
|
28
|
Wang R, Zhao D, Wang Y. Characterization of elemental distribution across human dentin-enamel junction by scanning electron microscopy with energy-dispersive X-ray spectroscopy. Microsc Res Tech 2020; 84:881-890. [PMID: 33210420 DOI: 10.1002/jemt.23648] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 10/26/2020] [Accepted: 11/04/2020] [Indexed: 11/08/2022]
Abstract
The human dentin-enamel junction (DEJ) is a natural junction that unites two dissimilar mineralized tissues in the human tooth: enamel and dentin. DEJ plays a critical role in maintaining structural and functional integrity of the tooth. However, its structure, chemical composition and function remain unclear and controversial. Systematic investigation of elemental distribution across human DEJ is still lacking in the literature. This study aimed to investigate the elemental distributions of Ca, P, O, C, N, Na, and Mg across the DEJ of human teeth using scanning electron microscope with energy dispersive spectroscopy of X-ray. The results revealed abrupt changes in the distributions of six elements (C, N, Ca, P, Na, and Mg) across the DEJ. Specifically, the four mineral elements showed similar level of change in distribution, with Ca, P, Na decreasing while Mg increasing by 21%-25% from enamel to dentin side of the DEJ. The two organic elements C and N showed much larger changes in distribution, with C increasing by ~150% and N increasing by ~270% from enamel to dentin side of the DEJ. The slope of the distribution curves across the DEJ was estimated to be ~2 μm in width and coincided with the phase intermixing of the micro-scallop structure of the DEJ.
Collapse
Affiliation(s)
- Rong Wang
- Department of Oral and Craniofacial Sciences, University of Missouri -Kansas City School of Dentistry, Kansas City, Missouri, USA
| | - Donggao Zhao
- Department of Oral and Craniofacial Sciences, University of Missouri -Kansas City School of Dentistry, Kansas City, Missouri, USA
| | - Yong Wang
- Department of Oral and Craniofacial Sciences, University of Missouri -Kansas City School of Dentistry, Kansas City, Missouri, USA
| |
Collapse
|
29
|
Camargos GDV, Lazari-Carvalho PC, Carvalho MAD, Castro MB, Neris NW, Del Bel Cury AA. 3D finite element model based on CT images of tooth. BRAZILIAN JOURNAL OF ORAL SCIENCES 2020. [DOI: 10.20396/bjos.v19i0.8658910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Aim: This study aimed the description of a protocol to acquire a 3D finite element (FE) model of a human maxillary central incisor tooth restored with ceramic crowns with enhanced geometric detail through an easy-to-use and low-cost concept and validate it through finite element analysis (FEA). Methods: A human maxillary central incisor was digitalized using a Cone Beam Computer Tomography (CBCT) scanner. The resulted tooth CBCT DICOM files were imported into a free medical imaging software (Invesalius) for 3D surface/geometric reconstruction in stereolithographic file format (STL). The STL file was exported to a computer-aided-design (CAD) software (SolidWorks), converted into a 3D solid model and edited to simulate different materials for full crown restorations. The obtained model was exported into a FEA software to evaluate the influence of different core materials (zirconia - Zr, lithium disilicate - Ds or palladium/silver - Ps) on the mechanical behavior of the restorations under a 100 N applied to the palatal surface at 135 degrees to the long axis of the tooth, followed by a load of 25.5 N perpendicular to the incisal edge of the crown. The quantitative and qualitative analysis of maximum principal stress (ceramic veneer) and maximum principal strain (core) were obtained. Results: The Zr model presented lower stress and strain concentration in the ceramic veneer and core than Ds and Ps models. For all models, the stresses were concentrated in the external surface of the veneering ceramic and strains in the internal surface of core, both near to the loading area. Conclusion: The described procedure is a quick, inexpensive and feasible protocol to obtain a highly detailed 3D FE model, and thus could be considered for future 3D FE analysis. The results of numerical simulation confirm that stiffer core materials result in a reduced stress concentration in ceramic veneer.
Collapse
|
30
|
Wang G, Chen Z, Qiu H, He T. Coadsorption of Na+ and H2O on the surface of hydroxylated silica. MOLECULAR SIMULATION 2020. [DOI: 10.1080/08927022.2020.1807018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Guanghui Wang
- School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou, People’s Republic of China
| | - Zherui Chen
- School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou, People’s Republic of China
| | - Hongxin Qiu
- School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou, People’s Republic of China
| | - Ting He
- School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou, People’s Republic of China
| |
Collapse
|
31
|
Lin JD, Ryder M, Kang M, Ho SP. Biomechanical pathways of dentoalveolar fibrous joints in health and disease. Periodontol 2000 2020; 82:238-256. [PMID: 31850635 DOI: 10.1111/prd.12306] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Spatial and temporal adaptations within periodontal tissues and their interfaces result from functional loads. Functional loads can be physiologic and/or pathologic in nature. The prolonged effect of these loads can alter the overall biomechanics of a dentoalveolar fibrous joint (dentoalveolar joint) by changing the form of the tooth root and its socket. This "sculpting" of the tooth root and alveolar bony socket is a consequence of several mechano-biological changes that occur within the periodontal complex of a load-bearing dentoalveolar joint. These include changes in biochemical expressions, structure, elemental composition, and mechanical properties of alveolar bone, the underlying tissues of the roots of teeth, and their interfaces. These physicochemical changes in tissues continue to prompt mechano-responsive biochemical activities at the attachment sites of periodontal ligament (soft) with bone (hard), and ligament with cementum (hard), which are the entheses of a load-bearing dentoalveolar joint. Forces at soft-hard tissue attachment sites between disparate materials with different stiffness values theoretically generate strain singularities or discontinuities. These discontinuities under prolonged functional loading increase the probability for failure to occur specifically at the enthesial zones. However, in a normal dentoalveolar joint, gradual stiffness gradients exist from ligament to bone, and from ligament to cementum. The gradual transitions in stiffness from softer ligament (lower stiffness) to harder bone or cementum (higher stiffness) or vice versa optimize tissue and interfacial strains. Optimization of tissue and ligament-enthesial physical and chemical properties facilitates transmission of cyclic forces of varying magnitudes and frequencies that collectively maintain the overall biomechanics of a dentoalveolar joint. The objectives of this review are 3-fold: (i) to illustrate physicochemical adaptations at the periodontal ligament entheses of a human periodontal complex affected by subgingival calculus; (ii) to demonstrate how to "program" the hallmarks of periodontitis in small-scale vertebrates in vivo to generate spatiotemporal maps of physicochemical adaptations in a diseased dentoalveolar joint; and (iii) to correlate dentoalveolar joint biomechanics in healthy and diseased states to spatiotemporal maps of physicochemical adaptations within respective periodontal tissues. This interdisciplinary approach demonstrates that physicochemical adaptations within periodontal tissues using the mechanics of materials (tissue mechanics), materials science (tissue composition), and mechano-biology (matrix molecules) can help explain the mechano-adaptation of dentoalveolar joints in normal and diseased functional states. Multiscale biomechanics and mechano-biology approaches can provide insights into the functional competence of a diseased relative to a normal dentoalveolar joint. Insights gathered from interdisciplinary and multiscale biomechanics approaches include the following: (i) physiologic loads related to chewing maintain a balance between mineral-forming and-resorbing biochemical cellular events, resulting in gradual stiffness gradients at the periodontal ligament entheses, and, in turn, sustain the overall biomechanics of a normal "healthy" dentoalveolar joint; (ii) pathologic loads resulting from tissue degradation and physical changes to the periodontal complex promote an abrupt stiffness gradient at the periodontal ligament entheses. The shift from gradual to an abrupt stiffness gradient could prompt a shift in the biochemical cascades, exacerbate mechano-responsive biochemical expressions at periodontal ligament entheses farther away from the site of insult, and culminate in joint degradation; (iii) sustained pathologic function on periodontally diseased joints exacerbates degradation of periodontal ligament entheses providing insights into "rescue therapy", such as the use of an adequate "mechanocal dose" to regain joint function; and (iv) spatiotemporal maps of changes in biochemical expressions, and physicochemical properties of strain-dominated affected sites, including the periodontal ligament entheses, can guide anatomy-specific therapeutics for tissue regeneration and/or disease control with the purpose of regaining dentoalveolar joint function. Modulation of occlusal loads could minimize disease progression and potentially assist in regaining functional attachment of ligament to bone and/or ligament to cementum of the dentoalveolar joint. Elucidating mechanisms that drive the breakdown of the functionally active periodontal complex burdened with microbes will provide the required critical insights into regenerative medicine and/or biomimetic approaches that would facilitate rescue/regain of dentoalveolar joint function.
Collapse
Affiliation(s)
- Jeremy D Lin
- Division of Preclinical Education, Biomaterials & Engineering, Department of Preventive and Restorative Dental Sciences, School of Dentistry, University of California San Francisco, San Francisco, California, USA
| | - Mark Ryder
- Division of Periodontics, Department of Orofacial Sciences, School of Dentistry, University of California San Francisco, San Francisco, California, USA
| | - Misun Kang
- Division of Preclinical Education, Biomaterials & Engineering, Department of Preventive and Restorative Dental Sciences, School of Dentistry, University of California San Francisco, San Francisco, California, USA
| | - Sunita P Ho
- Division of Preclinical Education, Biomaterials & Engineering, Department of Preventive and Restorative Dental Sciences, School of Dentistry, University of California San Francisco, San Francisco, California, USA.,Department of Urology, School of Medicine, University of California San Francisco, San Francisco, California, USA
| |
Collapse
|
32
|
YAMADA Y, INOUE T, SAITO M, NISHIMURA F, MIYAZAKI T. Anisotropic ultimate strength and microscopic fracture patterns during tensile testing in the dentin–enamel junction region. Dent Mater J 2020; 39:272-277. [DOI: 10.4012/dmj.2019-024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Yoshihiro YAMADA
- Department of Conservative Dentistry, Division of Biomaterials and Engineering, Showa University School of Dentistry
| | - Toshiko INOUE
- Department of Conservative Dentistry, Division of Biomaterials and Engineering, Showa University School of Dentistry
| | - Makoto SAITO
- Department of Conservative Dentistry, Division of Biomaterials and Engineering, Showa University School of Dentistry
| | - Fumio NISHIMURA
- Department of Conservative Dentistry, Division of Biomaterials and Engineering, Showa University School of Dentistry
| | - Takashi MIYAZAKI
- Department of Conservative Dentistry, Division of Biomaterials and Engineering, Showa University School of Dentistry
| |
Collapse
|
33
|
Thompson VP. The tooth: An analogue for biomimetic materials design and processing. Dent Mater 2020; 36:25-42. [DOI: 10.1016/j.dental.2019.08.106] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Revised: 08/21/2019] [Accepted: 08/28/2019] [Indexed: 01/05/2023]
|
34
|
Chen SE, Park AC, Wang J, Knoernschild KL, Campbell S, Yang B. Fracture Resistance of Various Thickness e.max CAD Lithium Disilicate Crowns Cemented on Different Supporting Substrates: An In Vitro Study. J Prosthodont 2019; 28:997-1004. [PMID: 31469479 DOI: 10.1111/jopr.13108] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/07/2019] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To investigate the influence of abutment material properties on the fracture resistance and failure mode of lithium disilicate (IPS e.max) CAD/CAM (computer-aided design/manufacturing) crowns on traditionally and minimally prepared simulated tooth substrates. MATERIALS AND METHODS Thirty lithium disilicate (IPS e.max) CAD/CAM crowns were divided into three groups (n = 10): TD: traditional thickness crowns cemented on Paradigm MZ100 abutments; MD: minimal thickness crowns cemented on Paradigm MZ100 abutments; ME: minimal thickness crowns cemented on e.max abutments. The 3Shape system was used to scan, design and mill all abutments and crowns with a die space set to 40 µm. Traditional thickness crowns were designed based on manufacturer guidelines with 1.5 mm occlusal thickness and 1.0 mm margins. Minimal thickness crowns were designed with 0.7 mm occlusal thickness and 0.5 mm margins. MZ100 composite and e.max abutments were selected to simulate dentin and enamel substrates, respectively, based on their elastic-modulus. Variolink Esthetic was used to cement all samples following manufacturer's instructions. A universal testing machine was used to load all specimens to fracture with a 3 mm radius stainless steel hemispherical tip at a crosshead speed 0.5 mm/minute along the longitudinal axis of the abutment with a 1 mm thermoplastic film placed between the loading tip and crown surface. Data was analyzed using ANOVA and Bonferroni post hoc assessment. Fractographic analysis was performed with scanning electron microscopy (SEM). RESULTS The mean fracture load (standard deviation) was 1499 (241) N for TD; 1228 (287) N for MD; and 1377 (96) N for ME. Statistically significant difference between groups did not exist (p = 0.157, F = 1.995). In groups TD and MD with low e-modulus abutments, the dispersion of a probability distribution (coefficient of variation: CV) was statistically higher than that of group ME with high e-modulus abutments. SEM illustrated larger micro-fracture dimensions in Group MD than Group ME. CONCLUSION Minimal thickness e.max crowns did not demonstrate statistical difference in fracture resistance from traditional thickness crowns. Fracture mechanisms of minimal thickness e.max crowns may be affected by the e-modulus of the substrate. Minimal thickness e.max crowns may be a viable restorative option when supported by high e-modulus materials.
Collapse
Affiliation(s)
- Sara Elizabeth Chen
- University of Illinois at Chicago - Restorative Dentistry, Chicago, IL, United States
| | | | - Jingxu Wang
- Department of Stomatology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Kent L Knoernschild
- University of Illinois at Chicago - Restorative Dentistry, Chicago, IL, United States
| | - Stephen Campbell
- University of Illinois at Chicago - Restorative Dentistry, Chicago, IL, United States
| | - Bin Yang
- University of Illinois at Chicago - Restorative Dentistry, Chicago, IL, United States
| |
Collapse
|
35
|
Anisotropic crack propagation and deformation in dentin observed by four-dimensional X-ray nano-computed tomography. Acta Biomater 2019; 96:400-411. [PMID: 31254684 DOI: 10.1016/j.actbio.2019.06.042] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2019] [Revised: 06/20/2019] [Accepted: 06/24/2019] [Indexed: 11/23/2022]
Abstract
Understanding the cracking behaviour of biological composite materials is of practical importance. This paper presents the first study to track the interplay between crack initiation, microfracture and plastic deformation in three dimensions (3D) as a function of tubule and collagen fibril arrangement in elephant dentin using in situ X-ray nano-computed tomography (nano-CT). A nano-indenter with a conical tip has been used to incrementally indent three test-pieces oriented at 0°, 45° and 70° to the long axis of the tubules (i.e. radial to the tusk). For the 0° sample two significant cracks formed, one of which linked up with microcracks in the axial-radial plane of the tusk originating from the tubules and the other one occurred as a consequence of shear deformation at the tubules. The 70° test-piece was able to bear the greatest loads despite many small cracks forming around the indenter. These were diverted by the microstructure and did not propagate significantly. The 45° test-piece showed intermediate behaviour. In all cases strains obtained by digital volume correlation were well in excess of the yield strain (0.9%), indeed some plastic deformation could even be seen through bending of the tubules. The hoop strains around the conical indenter were anisotropic with the smallest strains correlating with the primary collagen orientation (axial to the tusk) and the largest strains aligned with the hoop direction of the tusk. STATEMENT OF SIGNIFICANCE: This paper presents the first comprehensive study of the anisotropic nature of microfracture, crack propagation and deformation in elephant dentin using time-lapse X-ray nano-computed tomography. To unravel the interplay of collagen fibrils and local deformation, digital volume correlation (DVC) has been applied to map the local strain field while the crack initiation and propagation is tracked in real time. Our results highlight the intrinsic and extrinsic shielding mechanisms and correlate the crack growth behavior in nature to the service requirement of dentin to resist catastrophic fracture. This is of wide interest not just in terms of understanding dentin fracture but also can extend beyond dentin to other anisotropic structural composite biomaterials such as bone, antler and chitin.
Collapse
|
36
|
Hong H, Park SM, Kim D, Park SJ, Kim DS. Grayscale mask‐assisted photochemical crosslinking for a dense collagen construct with stiffness gradient. J Biomed Mater Res B Appl Biomater 2019; 108:1000-1009. [DOI: 10.1002/jbm.b.34452] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2019] [Revised: 06/12/2019] [Accepted: 07/17/2019] [Indexed: 12/13/2022]
Affiliation(s)
- Hyeonjun Hong
- Department of Mechanical EngineeringPohang University of Science and Technology (POSTECH) 77 Cheongam‐ro, Pohang Gyeongbuk 37673 South Korea
| | - Sang Min Park
- Department of Mechanical EngineeringPohang University of Science and Technology (POSTECH) 77 Cheongam‐ro, Pohang Gyeongbuk 37673 South Korea
| | - Dohui Kim
- Department of Mechanical EngineeringPohang University of Science and Technology (POSTECH) 77 Cheongam‐ro, Pohang Gyeongbuk 37673 South Korea
| | - Sung Jea Park
- Advanced Technology Research Center & School of Mechanical EngineeringKorea University of Technology and Education (KOREATECH) Cheonan Chungnam 31253 South Korea
| | - Dong Sung Kim
- Department of Mechanical EngineeringPohang University of Science and Technology (POSTECH) 77 Cheongam‐ro, Pohang Gyeongbuk 37673 South Korea
| |
Collapse
|
37
|
Edelhoff D, Güth JF, Erdelt K, Brix O, Liebermann A. Clinical performance of occlusal onlays made of lithium disilicate ceramic in patients with severe tooth wear up to 11 years. Dent Mater 2019; 35:1319-1330. [PMID: 31256912 DOI: 10.1016/j.dental.2019.06.001] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 06/11/2019] [Accepted: 06/17/2019] [Indexed: 11/17/2022]
Abstract
OBJECTIVES Evaluation of survival and complication rate of monolithic occlusal onlays made of lithium disilicate ceramic used in patients with severe tooth wear up to 11years of clinical service. METHODS In a prospective non-randomized clinical study 7 patients (4 male, 3 female; median age: 44.3±6.56years old) were restored full mouth with a total of 103 adhesively bonded occlusal onlays made of lithium disilicate ceramic (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein). All restorations were examined during annual recall visits using periodontal parameters according to the modified United States Public Health Service (USPHS) criteria: (a) marginal discoloration, (b) secondary caries, (c) marginal integrity, (d) surface texture, (e) restoration fracture, and (f) occlusal wear, rating with Alpha, Bravo and Charlie over an observation period up to 11years (68-139 months; median: 94.9±26.1 months). Data was statistically analyzed using the Kaplan-Meier estimation. RESULTS Monolithic lithium disilicate occlusal onlays presented a 100% survival rate. Four restorations within one patient (3.9%) presented marginal discoloration, one after 60 and three after 108 months (all rated Bravo). One restoration (1%) showed a marginal crack formation (technical complication) after 120 months, rated Bravo. No biological complication, debonding or secondary caries could be found and tested periodontal parameters showed excellent results. SIGNIFICANCE Based on the analyzed data up to 11years, monolithic occlusal onlays made of lithium disilicate ceramic can be considered as a reliable treatment option for full-mouth rehabilitations in patients with severe tooth wear.
Collapse
Affiliation(s)
- D Edelhoff
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| | - J F Güth
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| | - K Erdelt
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany
| | - O Brix
- Innovative Dentaldesign Oliver Brix, Kisseleffstraße 1a, 61348 Bad Homburg, Germany
| | - A Liebermann
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.
| |
Collapse
|
38
|
Kundanati L, D'Incau M, Bernardi M, Scardi P, Pugno NM. A comparative study of the mechanical properties of a dinosaur and crocodile fossil teeth. J Mech Behav Biomed Mater 2019; 97:365-374. [PMID: 31158580 DOI: 10.1016/j.jmbbm.2019.05.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 05/15/2019] [Accepted: 05/16/2019] [Indexed: 11/15/2022]
Abstract
Vertebrate teeth are complex structures adapted in terms of shape and structure to serve a variety of functions like biting and grinding. Thus, examining the morphology, composition and mechanical properties of the teeth can aid in providing insights into the feeding behaviour of extinct species. We here provide the first mechanical characterisation of teeth in a spinosaurid dinosaur, Suchomimus tenerensis, and a pholidosaurid crocodylomorph, Sarcosuchus imperator. Our results show that both species have similar macrostructure of enamel, dental and interfacial layers, and similar composition, the main constituent being fluorapatite. Microindentation tests show that Suchomimus teeth have lower elastic modulus and hardness, as compared to Sarchosuchus. On the contrary, Sarcosuchus teeth have lower toughness. Nanoindentation showed the existence of mechanical gradients from dentin to enamel in Suchomimus and, less prominently, in Sarcosuchus. This was also supported by wear tests showing that in Suchomimus the dentin region is more wear-prone than the enamel region. With still scarce information available on the dietary regimes in extinct species, the analysis of micro and nano-mechanical properties of fossils teeth might be a help in targeting specific biological questions. However, much is still unknown concerning the changes underwent by organic material during diagenesis making at present impossible to definitely conclude if the differences in the mechanical properties of Suchomimus and Sarchosuchus here retrieved imply that the two species adopted different strategies when dealing with food processing or are the result of disparate taphonomic histories.
Collapse
Affiliation(s)
- Lakshminath Kundanati
- Laboratory of Bio-inspired and Graphene Nanomechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, 38123, Italy
| | - Mirco D'Incau
- Department of Civil, Environmental and Mechanical Engineering, University of Trento, Via Mesiano 77, 38123, Trento, Italy
| | - Massimo Bernardi
- MUSE - Museo delle Scienze di Trento, Corso del Lavoro e della Scienza 3, 38122, Trento, Italy
| | - Paolo Scardi
- Department of Civil, Environmental and Mechanical Engineering, University of Trento, Via Mesiano 77, 38123, Trento, Italy
| | - Nicola M Pugno
- Laboratory of Bio-inspired and Graphene Nanomechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, 38123, Italy; School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London, E1 4NS, United Kingdom; Ket-Lab, Edoardo Amaldi Foundation, Via del Politecnico snc, 00133, Roma, Italy.
| |
Collapse
|
39
|
The potential of three-dimensional printing technologies to unlock the development of new ‘bio-inspired’ dental materials: an overview and research roadmap. J Prosthodont Res 2019; 63:131-139. [DOI: 10.1016/j.jpor.2018.10.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 10/05/2018] [Accepted: 10/26/2018] [Indexed: 11/23/2022]
|
40
|
Ghods S, Murcia S, Ossa E, Arola D. Designed for resistance to puncture: The dynamic response of fish scales. J Mech Behav Biomed Mater 2019; 90:451-459. [DOI: 10.1016/j.jmbbm.2018.10.037] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2017] [Revised: 05/25/2018] [Accepted: 10/30/2018] [Indexed: 01/16/2023]
|
41
|
Toyama DY, Alves LMM, Ramos GF, Campos TMB, de Vasconcelos G, Borges ALS, de Melo RM. Bioinspired silica-infiltrated zirconia bilayers: Strength and interfacial bonding. J Mech Behav Biomed Mater 2019; 89:143-149. [DOI: 10.1016/j.jmbbm.2018.09.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Revised: 08/24/2018] [Accepted: 09/11/2018] [Indexed: 01/12/2023]
|
42
|
Hayashi-Sakai S, Sakamoto M, Hayashi T, Kondo T, Sugita K, Sakai J, Shimomura-Kuroki J, Ike M, Nikkuni Y, Nishiyama H. Evaluation of permanent and primary enamel and dentin mineral density using micro-computed tomography. Oral Radiol 2018; 35:29-34. [PMID: 30484178 DOI: 10.1007/s11282-018-0315-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Accepted: 12/29/2017] [Indexed: 11/24/2022]
Abstract
OBJECTIVES The present study was performed to investigate the mineral density distribution in enamel and dentin for both permanent and primary teeth and to establish the standard density per tooth type using micro-computed tomography (CT). METHODS Fifty-seven extracted human teeth (37 permanent, 20 primary) were evaluated in the present study. The enamel and dentin mineral densities in the extracted teeth were measured using micro-CT. Cubic regression curves were used to determine the mineral density distribution in the enamel and dentin for each tooth type. RESULTS The mean values, distributions, and regression equations of the mineral densities were obtained. The mean mineral density values for permanent enamel and dentin were significantly higher than those for their primary counterparts for each tooth type. CONCLUSIONS In the present study, we demonstrated the distribution of mineral density in sound enamel and dentin and attempted to determine the standard mineral density for each tooth type using micro-CT. The mineral density distributions found in this study contribute to our understanding of the mechanical properties of enamel and dentin. A positive correlation suggests that the systemic bone mineral density could be predicted based on the analysis of exfoliated teeth, such as in patients with hypophosphatasia. The present results may be useful in establishing a numerical standard for the mechanism involved in root fracture and for early detection of root fracture risk.
Collapse
Affiliation(s)
- Sachiko Hayashi-Sakai
- Division of Oral and Maxillofacial Radiology, Niigata University Graduate School of Medical and Dental Sciences, 5274 Gakkocho-dori, Chuo-ku, Niigata, 951-8514, Japan.
| | - Makoto Sakamoto
- Department of Health Sciences, Faculty of Medicine, Niigata University, 2-746 Asahimachi-dori, Chuo-ku, Niigata, 951-8518, Japan
| | - Takafumi Hayashi
- Division of Oral and Maxillofacial Radiology, Niigata University Graduate School of Medical and Dental Sciences, 5274 Gakkocho-dori, Chuo-ku, Niigata, 951-8514, Japan
| | - Tatsuya Kondo
- Department of Health Sciences, Faculty of Medicine, Niigata University, 2-746 Asahimachi-dori, Chuo-ku, Niigata, 951-8518, Japan
| | - Kaito Sugita
- Department of Health Sciences, Faculty of Medicine, Niigata University, 2-746 Asahimachi-dori, Chuo-ku, Niigata, 951-8518, Japan
| | - Jun Sakai
- Department of System and Automotive Engineering, Niigata College of Technology, 5-13-7 Kamishinei-cho, Nishi-ku, Niigata, 950-2076, Japan
| | - Junko Shimomura-Kuroki
- Department of Pediatric Dentistry, The Nippon Dental University, School of Life Dentistry at Niigata, 1-8 Hamaura-cho, Chuo-ku, Niigata, 951-8580, Japan
| | - Makiko Ike
- Division of Oral and Maxillofacial Radiology, Niigata University Graduate School of Medical and Dental Sciences, 5274 Gakkocho-dori, Chuo-ku, Niigata, 951-8514, Japan
| | - Yutaka Nikkuni
- Division of Oral and Maxillofacial Radiology, Niigata University Graduate School of Medical and Dental Sciences, 5274 Gakkocho-dori, Chuo-ku, Niigata, 951-8514, Japan
| | - Hideyoshi Nishiyama
- Division of Oral and Maxillofacial Radiology, Niigata University Graduate School of Medical and Dental Sciences, 5274 Gakkocho-dori, Chuo-ku, Niigata, 951-8514, Japan
| |
Collapse
|
43
|
Warangkulkasemkit S, Pumpaluk P. Comparison of physical properties of three commercial composite core build-up materials. Dent Mater J 2018; 38:177-181. [PMID: 30381634 DOI: 10.4012/dmj.2018-038] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Various materials have been used for core build-up when restoring the coronal portion of the tooth. Currently, bulk-fill resin composites have been produced to restore a large posterior cavity in single increment. This study aimed to evaluate the compressive strength, flexural strength, and microhardness of three commercial composite core build-up materials. All data were analyzed by oneway ANOVA and Tukey test methods (α=0.05). Flexural strength data were subjected to Weibull statistics analysis. All three groups presented significant differences in the compressive strength, flexural strength, and Knoop hardness. FiltekTM Z350 XT had the greatest compressive strength (MPa) and Knoop hardness while FiltekTM bulk fill had the highest flexural strength. MultiCore®Flow had the lowest properties; however, it revealed the highest Weibull modulus (m) value. With regard to the properties tested in this study, bulk-fill resin composite can be used as an alternative to conventional resin composite for core build-up material.
Collapse
Affiliation(s)
| | - Piyapanna Pumpaluk
- Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University
| |
Collapse
|
44
|
Eldafrawy M, Nguyen J, Mainjot A, Sadoun M. A Functionally Graded PICN Material for Biomimetic CAD-CAM Blocks. J Dent Res 2018; 97:1324-1330. [DOI: 10.1177/0022034518785364] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
The objective of this study was to introduce a functionally graded (FG) polymer-infiltrated ceramic network (PICN) block, characterized by a gradient of mechanical properties, as a biomimetic material for computer-aided design and manufacturing (CAD-CAM) prostheses. FG-PICN blocks were manufactured from a slurry of glass-ceramic powder, which was subsequently centrifuged and sintered. The ceramic network was infiltrated with urethane dimethacrylate and polymerized under high temperature-pressure. Blocks were sectioned into 9 layers, and each layer was subsequently cut into 3 samples. Samples were loaded into a 3-point bending device and tested for flexural strength, flexural load energy, and flexural modulus. The volume percentage of glass-ceramic, hardness, and brittleness index were also measured and scanning electron microscopy (SEM) observations were performed. Katana translucent zirconia (HT-ZIR) and e.max-CAD (EMX) were tested for comparison. Flexural strength, flexural load energy, and Weibull modulus of FG-PICN were shown to increase from the first (enamel-like zone) to the ninth layer (dentin-like zone), while, on the contrary, flexural modulus, hardness, brittleness index, and ceramic volume percentage decreased. SEM characterization highlighted a higher porosity in layer 9 than in layer 1. Flexural strength of the dentin-like zone (372.7 ± 27.8 MPa) was similar to EMX and lower than HT-ZIR. Flexural modulus was shown to vary from 41.9 ± 5.1 to 28.6 ± 2.0 GPa from surface to depth. Flexural load energy in the dentin-like zone (27.1 ± 4.9 mJ) was significantly superior to EMX and HT-ZIR. Hardness gradient was shown to be close to tooth tissues. This work introduces FG-PICN blocks, with a gradient of mechanical and optical properties through the entire thickness of the block designed to mimic dental tissues. FG-PICN demonstrated a favorable gradient of flexural strength, elastic modulus, and, most of all, flexural load energy and hardness compared to other CAD-CAM materials, which can promote the biomechanical behavior of single-unit restorations on teeth and implants.
Collapse
Affiliation(s)
- M. Eldafrawy
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège), Liège, Belgium
| | - J.F. Nguyen
- UFR d’Odontologie, Université Paris Diderot, Paris, France
- PSL Research University, Chimie ParisTech-CNRS, Institut de Recherche de Chimie Paris, Paris, France
| | - A.K. Mainjot
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège), Liège, Belgium
- Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège Hospital (CHU), Liège, Belgium
| | | |
Collapse
|
45
|
Seyedmahmoud R, Wang Y, Thiagarajan G, Gorski JP, Reed Edwards R, McGuire JD, Walker MP. Oral cancer radiotherapy affects enamel microhardness and associated indentation pattern morphology. Clin Oral Investig 2018; 22:1795-1803. [PMID: 29151196 PMCID: PMC5908727 DOI: 10.1007/s00784-017-2275-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Accepted: 11/13/2017] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aim of this study is to determine the effects of in vitro and in vivo high-dose radiotherapy on microhardness and associated indentation pattern morphology of enamel. MATERIALS AND METHODS The inner, middle, and outer microhardness of enamel was evaluated using three experimental groups: control (non-radiated); in vitro irradiated; in vivo irradiated. In vitro specimens were exposed to simulated radiotherapy, and in vivo specimens were extracted teeth from oral cancer patients previously treated with radiotherapy. Indentations were measured via SEM images to calculate microhardness values and to assess the mechanomorphological properties of enamel before and after radiotherapy. RESULTS Middle and outer regions of enamel demonstrated a significant decrease in microhardness after in vitro and in vivo irradiation compared to the control group (p < 0.05). Two indentation patterns were observed: pattern A-presence of microcracks around indent periphery, which represents local dissipation of deformation energy; pattern B-clean, sharp indents. The percentage of clean microindentation patterns, compared to controls, was significantly higher following in vitro and in vivo irradiation in all enamel regions. The highest percentage of clean microindentations (65%) was observed in the in vivo irradiated group in the inner region of enamel near the dentin-enamel junction. CONCLUSIONS For the first time, this study shows that in vitro and in vivo irradiation alters enamel microhardness. Likewise, the indentation pattern differences suggest that enamel may become more brittle following in vitro and in vivo irradiation. CLINICAL RELEVANCE The mechanomorphological property changes of enamel following radiation may be a contributory component of pathologic enamel delamination following oral cancer radiotherapy.
Collapse
Affiliation(s)
- R Seyedmahmoud
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA
| | - Y Wang
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA.
- Center of Excellence in Musculoskeletal and Dental Tissues, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA.
| | - G Thiagarajan
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA
- Department of Civil and Mechanical Engineering, School of Computing and Engineering, University of Missouri-Kansas City, Kansas City, MO, USA
| | - J P Gorski
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA
- Center of Excellence in Musculoskeletal and Dental Tissues, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA
| | - R Reed Edwards
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA
| | - J D McGuire
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA
| | - M P Walker
- Department of Oral and Craniofacial Sciences, School of Dentistry, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA.
- Center of Excellence in Musculoskeletal and Dental Tissues, University of Missouri-Kansas City, 650 East 25th St, Kansas City, MO, 64108, USA.
| |
Collapse
|
46
|
Bakhsh TA, Bakry AS, Mandurah MM, Abbassy MA. Novel evaluation and treatment techniques for white spot lesions. An in vitro study. Orthod Craniofac Res 2018; 20:170-176. [PMID: 28727319 DOI: 10.1111/ocr.12193] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/28/2017] [Indexed: 11/28/2022]
Abstract
OBJECTIVE White spot lesions (WSLs) are commonly seen during and after orthodontic treatment. Therefore, the objective of this in vitro study was to assess the effect of 45S5-bioglass in remineralizing WSLs using cross-polarization optical coherence tomography (CP-OCT) and confirm the findings by micro-hardness test. METHODS Ceramic orthodontic brackets were bonded to the buccal surface of 45 human premolars with Transbond XT primer followed by Transbond PLUS according to the manufacturer's instructions. Then, all specimens were varnished excluding the area of interest (AOI) around the bonded brackets, immersed in demineralizing solution and divided into three groups: BG, REM and CONT. In BG group, 15 specimens were treated with bioglass paste for 24 hours. REM group had 15 specimens stored in remineralization solution for 24 hours. CONT group had the remaining 15 specimens with no treatment. All specimens were examined under CP-OCT and tested using cross-sectional micro-hardness techniques. RESULTS CP-OCT analysis showed that the maximum pixel value after bioglass application was significantly increased at AOI when compared to CONT and REM groups (P>.05), which was confirmed by the cross-sectional micro-hardness results (P>.05). CONCLUSION Early enamel demineralization and remineralization can be easily and non-invasively monitored with CP-OCT. Bioglass is a potent remineralizing agent.
Collapse
Affiliation(s)
- T A Bakhsh
- Operative Dentistry Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - A S Bakry
- Operative Dentistry Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.,Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - M M Mandurah
- King Abdulaziz Hospital, Ministry of Health, Makkah, Saudi Arabia
| | - M A Abbassy
- Department of Orthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.,Alexandria University, Alexandria, Egypt
| |
Collapse
|
47
|
Wang Z, Wang K, Xu W, Gong X, Zhang F. Mapping the mechanical gradient of human dentin-enamel-junction at different intratooth locations. Dent Mater 2018; 34:376-388. [DOI: 10.1016/j.dental.2017.11.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Revised: 10/30/2017] [Accepted: 11/01/2017] [Indexed: 10/18/2022]
|
48
|
Deang JF, Persons AK, Oppedal AL, Rhee H, Moser RD, Horstemeyer MF. Structure, property, and function of sheepshead (Archosargus probatocephalus) teeth. Arch Oral Biol 2018; 89:1-8. [PMID: 29407634 DOI: 10.1016/j.archoralbio.2018.01.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 12/14/2017] [Accepted: 01/17/2018] [Indexed: 11/30/2022]
Abstract
OBJECTIVES This paper studies A. probatocephalus teeth and investigates the mechanical properties and chemical composition of the enameloid and dentin. DESIGN Nanoindentation tests with a max load of 1000 μN and X-ray Energy Dispersive Spectroscopy (EDS) were performed along the diameter of the polished sample. Microstructural analysis of the dentin tubules was performed from SEM images. RESULTS From nanoindentation testing, the dentin of the sheepshead teeth has a nanoindentation hardness of 0.89 ± 0.21 (mean ± S.D.) GPa and a reduced Young's modulus of 23.29 ± 5.30 GPa. The enameloid of A. probatocephalus has a hardness of 4.36 ± 0.44 GPa and a mean reduced Young's modulus of 98.14 ± 6.91 GPa. Additionally, nanoindentation tests showed that the enameloid's hardness and modulus increased closer to the surface of the tooth. X-ray Energy Dispersive Spectroscopy (EDS) data further suggests that the gradient may be a result of the wt% fluoride within the enameloid, where an increase in fluoride results in an increase in reduced Young's modulus and hardness. CONCLUSION The microstructural characterization of the number density and area of the dentin tubules were used to address the porosity effect in the dentin to achieve the experimentally validated microhardness. The mechanical properties of the sheepshead teeth were also compared with previous nanoindentation tests from other aquatic species. The sheepshead teeth exhibit a greater reduced Young's modulus and hardness compared to shark and piranha teeth.
Collapse
Affiliation(s)
- J F Deang
- Department of Mechanical Engineering, Mississippi State University, Mississippi State, MS 39762, USA; Center for Advanced Vehicular Systems, Mississippi State University, Mississippi State, MS 39762, USA.
| | - A K Persons
- Department of Mechanical Engineering, Mississippi State University, Mississippi State, MS 39762, USA; Center for Advanced Vehicular Systems, Mississippi State University, Mississippi State, MS 39762, USA
| | - A L Oppedal
- Center for Advanced Vehicular Systems, Mississippi State University, Mississippi State, MS 39762, USA
| | - H Rhee
- Department of Mechanical Engineering, Mississippi State University, Mississippi State, MS 39762, USA; Center for Advanced Vehicular Systems, Mississippi State University, Mississippi State, MS 39762, USA
| | - R D Moser
- US Army Engineer Research and Development Center, Geotechnical and Structures Laboratory, 3909 Halls Ferry Rd., Vicksburg, MS 39180, USA
| | - M F Horstemeyer
- Department of Mechanical Engineering, Mississippi State University, Mississippi State, MS 39762, USA; Center for Advanced Vehicular Systems, Mississippi State University, Mississippi State, MS 39762, USA
| |
Collapse
|
49
|
SUN XINGDONG, FAN ZUNQIANG, ZHANG SHIZHONG, WU DI, ZHONG YUEXI, ZHAO HONGWEI, REN LUQUAN. A DAMAGE MECHANISM OF MICRO-PARTICLES ON ARTICULAR CARTILAGE OF KNEE BY NANOINDENTATION. J MECH MED BIOL 2018. [DOI: 10.1142/s0219519417501160] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Articular cartilage plays an important role in organism due to its excellent shock absorbing and buffering functions. Increasing problems about damages of articular cartilage are making a great deal of trouble to human beings. The damage mechanism of articular cartilage is very complicated and keeps unclear. In this research, the damage mechanism was investigated from the perspective of micro-particle attrition by nanoindentation experiments. The micro-particle was simulated by the indenter in experiments. The experimental results demonstrated that the load from micro-particle could not maintain when water content was adequate. However, the load could maintain and increase after dehydration. It was found that the partial surface of articular cartilage was crushed and adhered to the indenter. The plastic energy was bigger than elastic energy in the nanoindentation process. Therefore, water content was the crucial factor to protect the articular cartilage from damage. And the recurring partial dehydration owing to ongoing compression enhanced the damage of micro-particle to articular cartilage. This research may provide a new understanding to the damage mechanism of articular cartilage.
Collapse
Affiliation(s)
- XINGDONG SUN
- School of Mechanical Science and Engineering, Jilin University, Changchun 130025, P. R. China
| | - ZUNQIANG FAN
- School of Mechanical Science and Engineering, Jilin University, Changchun 130025, P. R. China
| | - SHIZHONG ZHANG
- School of Mechanical Science and Engineering, Jilin University, Changchun 130025, P. R. China
| | - DI WU
- School of Mechanical Science and Engineering, Jilin University, Changchun 130025, P. R. China
| | - YUEXI ZHONG
- School of Mechanical Science and Engineering, Jilin University, Changchun 130025, P. R. China
| | - HONGWEI ZHAO
- School of Mechanical Science and Engineering, Jilin University, Changchun 130025, P. R. China
| | - LUQUAN REN
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130025, P. R. China
| |
Collapse
|
50
|
Thiagarajan G, Vizcarra B, Bodapudi V, Reed R, Seyedmahmoud R, Wang Y, Gorski JP, Walker MP. Stress analysis of irradiated human tooth enamel using finite element methods. Comput Methods Biomech Biomed Engin 2017; 20:1533-1542. [PMID: 29063816 DOI: 10.1080/10255842.2017.1383401] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The objectives of this project were to use finite element methods to determine how changes in the elastic modulus due to oral cancer therapeutic radiation alter the distribution of mechanical stresses in teeth and to determine if observed failures in irradiated teeth correlate with changes in mechanical stresses. A thin slice section finite element (FE) model was constructed from micro CT sections of a molar tooth using MIMICS and 3-Matic software. This model divides the tooth into three enamel regions, the dentin-enamel junction (DEJ) and dentin. The enamel elastic modulus was determined in each region using nano indentation for three experimental groups namely - control (non-radiated), in vitro irradiated (simulated radiotherapy following tooth extraction) and in vivo irradiated (extracted subsequent to oral cancer patient radiotherapy) teeth. Physiological loads were applied to the tooth models at the buccal and lingual cusp regions for all three groups (control, in vitro and in vivo). The principal tensile stress and the maximum shear stress were used to compare the results from different groups since it has been observed in previous studies that delamination of enamel from the underlying dentin was one of the major reasons for the failure of teeth following therapeutic radiation. From the FE data, we observed an increase in the principal tensile stress within the inner enamel region of in vivo irradiated teeth (9.97 ± 1.32 MPa) as compared to control/non-irradiated teeth (8.44 ± 1.57 MPa). Our model predicts that failure occurs at the inner enamel/DEJ interface due to extremely high tensile and maximum shear stresses in in vivo irradiated teeth which could be a cause of enamel delamination due to radiotherapy.
Collapse
Affiliation(s)
- Ganesh Thiagarajan
- a Department of Civil and Mechanical Engineering, School of Computing and Engineering , University of Missouri-Kansas City , Kansas City , MO , USA.,c Center for Excellence in the Study of Dental and Musculoskeletal Tissues , University of Missouri-Kansas City , Kansas City , MO , USA
| | - Bruno Vizcarra
- a Department of Civil and Mechanical Engineering, School of Computing and Engineering , University of Missouri-Kansas City , Kansas City , MO , USA.,c Center for Excellence in the Study of Dental and Musculoskeletal Tissues , University of Missouri-Kansas City , Kansas City , MO , USA
| | - Venkata Bodapudi
- a Department of Civil and Mechanical Engineering, School of Computing and Engineering , University of Missouri-Kansas City , Kansas City , MO , USA.,c Center for Excellence in the Study of Dental and Musculoskeletal Tissues , University of Missouri-Kansas City , Kansas City , MO , USA
| | - Rachel Reed
- b Department of Oral and Craniofacial Sciences, School of Dentistry , University of Missouri-Kansas City , Kansas City , MO , USA.,c Center for Excellence in the Study of Dental and Musculoskeletal Tissues , University of Missouri-Kansas City , Kansas City , MO , USA
| | - Rasoul Seyedmahmoud
- b Department of Oral and Craniofacial Sciences, School of Dentistry , University of Missouri-Kansas City , Kansas City , MO , USA.,c Center for Excellence in the Study of Dental and Musculoskeletal Tissues , University of Missouri-Kansas City , Kansas City , MO , USA
| | - Yong Wang
- b Department of Oral and Craniofacial Sciences, School of Dentistry , University of Missouri-Kansas City , Kansas City , MO , USA.,c Center for Excellence in the Study of Dental and Musculoskeletal Tissues , University of Missouri-Kansas City , Kansas City , MO , USA
| | - Jeffrey P Gorski
- b Department of Oral and Craniofacial Sciences, School of Dentistry , University of Missouri-Kansas City , Kansas City , MO , USA.,c Center for Excellence in the Study of Dental and Musculoskeletal Tissues , University of Missouri-Kansas City , Kansas City , MO , USA
| | - Mary P Walker
- b Department of Oral and Craniofacial Sciences, School of Dentistry , University of Missouri-Kansas City , Kansas City , MO , USA.,c Center for Excellence in the Study of Dental and Musculoskeletal Tissues , University of Missouri-Kansas City , Kansas City , MO , USA
| |
Collapse
|