Yildirim DK, Uzun D, Bruce CG, Khan JM, Rogers T, Schenke WH, Ramasawmy R, Campbell-Washburn A, Herzka D, Lederman RJ, Kocaturk O. An interventional MRI guidewire combining profile and tip conspicuity for catheterization at 0.55T. Magn Reson Med 2023; 89:845-858. [PMID: 36198118 PMCID: PMC9712240 DOI: 10.1002/mrm.29466] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 08/04/2022] [Accepted: 09/02/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE We describe a clinical grade, "active", monopole antenna-based metallic guidewire that has a continuous shaft-to-tip image profile, a pre-shaped tip-curve, standard 0.89 mm (0.035″) outer diameter, and a detachable connector for catheter exchange during cardiovascular catheterization at 0.55T. METHODS Electromagnetic simulations were performed to characterize the magnetic field around the antenna whip for continuous tip visibility. The active guidewire was manufactured using medical grade materials in an ISO Class 7 cleanroom. RF-induced heating of the active guidewire prototype was tested in one gel phantom per ASTM 2182-19a, alone and in tandem with clinical metal-braided catheters. Real-time MRI visibility was tested in one gel phantom and in-vivo in two swine. Mechanical performance was compared with commercial equivalents. RESULTS The active guidewire provided continuous "profile" shaft and tip visibility in-vitro and in-vivo, analogous to guidewire shaft-and-tip profiles under X-ray. The MRI signal signature matched simulation results. Maximum unscaled RF-induced temperature rise was 5.2°C and 6.5°C (3.47 W/kg local background specific absorption rate), alone and in tandem with a steel-braided catheter, respectively. Mechanical characteristics matched commercial comparator guidewires. CONCLUSION The active guidewire was clearly visible via real-time MRI at 0.55T and exhibits a favorable geometric sensitivity profile depicting the guidewire continuously from shaft-to-tip including a unique curved-tip signature. RF-induced heating is clinically acceptable. This design allows safe device navigation through luminal structures and heart chambers. The detachable connector allows delivery and exchange of cardiovascular catheters while maintaining guidewire position. This enhanced guidewire design affords the expected performance of X-ray guidewires during human MRI catheterization.
Collapse
Affiliation(s)
- Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Dogangun Uzun
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Christopher G. Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Jaffar M. Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - William H. Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Daniel Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| |
Collapse
|
2
|
Yildirim DK, Bruce C, Uzun D, Rogers T, O'Brien K, Ramasawmy R, Campbell-Washburn A, Herzka DA, Lederman RJ, Kocaturk O. A 20-gauge active needle design with thin-film printed circuitry for interventional MRI at 0.55T. Magn Reson Med 2021; 86:1786-1801. [PMID: 33860962 DOI: 10.1002/mrm.28804] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 03/05/2021] [Accepted: 03/23/2021] [Indexed: 01/14/2023]
Abstract
PURPOSE This work aims to fabricate RF antenna components on metallic needle surfaces using biocompatible polyester tubing and conductive ink to develop an active interventional MRI needle for clinical use at 0.55 Tesla. METHODS A custom computer numeric control-based conductive ink printing method was developed. Based on electromagnetic simulation results, thin-film RF antennas were printed with conductive ink and used to fabricate a medical grade, 20-gauge (0.87 mm outer diameter), 90-mm long active interventional MRI needle. The MRI visibility performance of the active needle prototype was tested in vitro in 1 gel phantom and in vivo in 1 swine. A nearly identical active needle constructed using a 44 American Wire Gauge insulated copper wire-wound RF receiver antenna was a comparator. The RF-induced heating risk was evaluated in a gel phantom per American Society for Testing and Materials (ASTM) 2182-19. RESULTS The active needle prototype with printed RF antenna was clearly visible both in vitro and in vivo under MRI. The maximum RF-induced temperature rise of prototypes with printed RF antenna and insulated copper wire antenna after a 3.96 W/kg, 15 min. long scan were 1.64°C and 8.21°C, respectively. The increase in needle diameter was 98 µm and 264 µm for prototypes with printed RF antenna and copper wire-wound antenna, respectively. CONCLUSION The active needle prototype with conductive ink printed antenna provides distinct device visibility under MRI. Variations on the needle surface are mitigated compared to use of a 44 American Wire Gauge copper wire. RF-induced heating tests support device RF safety under MRI. The proposed method enables fabrication of small diameter active interventional MRI devices having complex geometries, something previously difficult using conventional methods.
Collapse
Affiliation(s)
- Dursun Korel Yildirim
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christopher Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Dogangun Uzun
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kendall O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
3
|
Panych LP, Madore B. The physics of MRI safety. J Magn Reson Imaging 2017; 47:28-43. [DOI: 10.1002/jmri.25761] [Citation(s) in RCA: 82] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Accepted: 04/24/2017] [Indexed: 01/25/2023] Open
Affiliation(s)
- Lawrence P. Panych
- Department of Radiology; Brigham and Women's Hospital; Boston Massachusetts USA
- Harvard Medical School; Boston Massachusetts USA
| | - Bruno Madore
- Department of Radiology; Brigham and Women's Hospital; Boston Massachusetts USA
- Harvard Medical School; Boston Massachusetts USA
| |
Collapse
|
4
|
Yamazaki M, Ideta T, Kudo S, Nakazawa M. Evaluation of Artificial Hip Joint with Radiofrequency Heating Issues during MRI Examination: A Comparison between 1.5 T and 3 T. Nihon Hoshasen Gijutsu Gakkai Zasshi 2016; 72:480-8. [PMID: 27320151 DOI: 10.6009/jjrt.2016_jsrt_72.6.480] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Masaru Yamazaki
- Department of Radiological Technology, Osaka City University Hospital
- Current address: Miyakojima IGRT Clinic, Medical Corporation Shinmeikai
| | - Takahiro Ideta
- Department of Radiological Technology, Osaka City University Hospital
| | - Sadahiro Kudo
- Department of Radiological Technology, Osaka City University Hospital
| | - Masami Nakazawa
- Department of Radiological Technology, Osaka City University Hospital
- Current address: Canon Lifecare Solutions Inc
| |
Collapse
|
5
|
MRI-based multiscale model for electromagnetic analysis in the human head with implanted DBS. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2013; 2013:694171. [PMID: 23956789 PMCID: PMC3727211 DOI: 10.1155/2013/694171] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2013] [Accepted: 05/29/2013] [Indexed: 11/23/2022]
Abstract
Deep brain stimulation (DBS) is an established procedure for the treatment of movement and affective disorders. Patients with DBS may benefit from magnetic resonance imaging (MRI) to evaluate injuries or comorbidities. However, the MRI radio-frequency (RF) energy may cause excessive tissue heating particularly near the electrode. This paper studies how the accuracy of numerical modeling of the RF field inside a DBS patient varies with spatial resolution and corresponding anatomical detail of the volume surrounding the electrodes. A multiscale model (MS) was created by an atlas-based segmentation using a 1 mm3 head model (mRes) refined in the basal ganglia by a 200 μm2 ex-vivo dataset. Four DBS electrodes targeting the left globus pallidus internus were modeled. Electromagnetic simulations at 128 MHz showed that the peak of the electric field of the MS doubled (18.7 kV/m versus 9.33 kV/m) and shifted 6.4 mm compared to the mRes model. Additionally, the MS had a sixfold increase over the mRes model in peak-specific absorption rate (SAR of 43.9 kW/kg versus 7 kW/kg). The results suggest that submillimetric resolution and improved anatomical detail in the model may increase the accuracy of computed electric field and local SAR around the tip of the implant.
Collapse
|
6
|
Tanaka R, Yumoto T, Shiba N, Okawa M, Yasuhara T, Ichikawa T, Tokunaga K, Date I, Ujike Y. Overheated and melted intracranial pressure transducer as cause of thermal brain injury during magnetic resonance imaging: case report. J Neurosurg 2012; 117:1100-9. [PMID: 23061386 DOI: 10.3171/2012.9.jns12738] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Magnetic resonance imaging is used with increasing frequency to provide accurate clinical information in cases of acute brain injury, and it is important to ensure that intracranial pressure (ICP) monitoring devices are both safe and accurate inside the MRI suite. A rare case of thermal brain injury during MRI associated with an overheated ICP transducer is reported. This 20-year-old man had sustained a severe contusion of the right temporal and parietal lobes during a motor vehicle accident. An MR-compatible ICP transducer was placed in the left frontal lobe. The patient was treated with therapeutic hypothermia, barbiturate therapy, partial right temporal lobectomy, and decompressive craniectomy. Immediately after MRI examination on hospital Day 6, the ICP monitor was found to have stopped working, and the transducer was subsequently removed. The patient developed meningitis after this event, and repeat MRI revealed additional brain injury deep in the white matter on the left side, at the location of the ICP transducer. It is suspected that this new injury was caused by heating due to the radiofrequency radiation used in MRI because it was ascertained that the tip of the transducer had been melted and scorched. Scanning conditions--including configuration of the transducer, MRI parameters such as the type of radiofrequency coil, and the specific absorption rate limit--deviated from the manufacturer's recommendations. In cooperation with the manufacturer, the authors developed a precautionary tag describing guidelines for safe MR scanning to attach to the display unit of the product. Strict adherence to the manufacturer's guidelines is very important for preventing serious complications in patients with ICP monitors undergoing MRI examinations.
Collapse
Affiliation(s)
- Reiichiro Tanaka
- Department of Critical Care and Emergency Medicine, Okayama University Hospital, Okayama, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Steerable catheter microcoils for interventional MRI reducing resistive heating. Acad Radiol 2011; 18:270-6. [PMID: 21075017 DOI: 10.1016/j.acra.2010.09.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2010] [Revised: 09/17/2010] [Accepted: 09/17/2010] [Indexed: 11/27/2022]
Abstract
RATIONALE AND OBJECTIVES The aims of this study were to assess resistive heating of microwires used for remote catheter steering in interventional magnetic resonance imaging and to investigate the use of alumina to facilitate heat transfer to saline flowing in the catheter lumen. MATERIALS AND METHODS A microcoil was fabricated using a laser lathe onto polyimide-tipped or alumina-tipped endovascular catheters. In vitro testing was performed on a 1.5-T magnetic resonance system using a vessel phantom, body radiofrequency coil, and steady-state pulse sequence. Resistive heating was measured with water flowing over a polyimide-tip catheter or saline flowing through the lumen of an alumina-tip catheter. Preliminary in vivo testing in porcine common carotid arteries was conducted with normal blood flow or after arterial ligation when current was applied to an alumina-tip catheter for up to 5 minutes. RESULTS After application of up to 1 W of direct current power, clinically significant temperature increases were noted with the polyimide-tip catheter: 23°C/W at zero flow, 13°C/W at 0.28 cm(3)/s, and 7.9°C/W at 1 cm(3)/s. Using the alumina-tip catheter, the effluent temperature rise using the lowest flow rate (0.12 cm(3)/s) was 2.3°C/W. In vivo testing demonstrated no thermal injury to vessel walls at normal and zero arterial flow. CONCLUSIONS Resistive heating in current carrying wire pairs can be dissipated by saline coolant flowing within the lumen of a catheter tip composed of material that facilitates heat transfer.
Collapse
|
8
|
Settecase F, Hetts SW, Martin AJ, Roberts TPL, Bernhardt AF, Evans L, Malba V, Saeed M, Arenson RL, Kucharzyk W, Wilson MW. RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI. Acad Radiol 2011; 18:277-85. [PMID: 21075019 DOI: 10.1016/j.acra.2010.09.012] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2010] [Revised: 09/07/2010] [Accepted: 09/17/2010] [Indexed: 11/28/2022]
Abstract
RATIONALE AND OBJECTIVES The aim of this study was too assess magnetic resonance imaging (MRI) radiofrequency (RF)-related heating of conductive wire coils used in magnetically steerable endovascular catheters. MATERIALS AND METHODS A three-axis microcoil was fabricated onto a 1.8Fr catheter tip. In vitro testing was performed on a 1.5-T MRI system using an agarose gel-filled vessel phantom, a transmit-receive body RF coil, a steady-state free precession pulse sequence, and a fluoroptic thermometry system. Temperature was measured without simulated blood flow at varying distances from the magnet isocenter and at varying flip angles. Additional experiments were performed with laser-lithographed single-axis microcoil-tipped microcatheters in air and in a saline bath with varied grounding of the microcoil wires. Preliminary in vivo evaluation of RF heating was performed in pigs at 1.5 T with coil-tipped catheters in various positions in the common carotid arteries with steady-state free precession pulse sequence on and off and under physiologic-flow and zero-flow conditions. RESULTS In tissue-mimicking agarose gel, RF heating resulted in a maximal temperature increase of 0.35°C after 15 minutes of imaging, 15 cm from the magnet isocenter. For a single-axis microcoil, maximal temperature increases were 0.73°C to 1.91°C in air and 0.45°C to 0.55°C in saline. In vivo, delayed contrast-enhanced MRI revealed no evidence of vascular injury, and histopathologic sections from the common carotid arteries confirmed the lack of vascular damage. CONCLUSIONS Microcatheter tip microcoils for endovascular catheter steering in MRI experience minimal RF heating under the conditions tested. These data provide the basis for further in vivo testing of this promising technology for endovascular interventional MRI.
Collapse
Affiliation(s)
- Fabio Settecase
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Avenue, L-352, San Francisco, CA 94143-0628, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Schouten MG, Ansems J, Renema WKJ, Bosboom D, Scheenen TWJ, Fütterer JJ. The accuracy and safety aspects of a novel robotic needle guide manipulator to perform transrectal prostate biopsies. Med Phys 2010; 37:4744-50. [DOI: 10.1118/1.3475945] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
10
|
Ratnayaka K, Faranesh AZ, Guttman MA, Kocaturk O, Saikus CE, Lederman RJ. Interventional cardiovascular magnetic resonance: still tantalizing. J Cardiovasc Magn Reson 2008; 10:62. [PMID: 19114017 PMCID: PMC2637847 DOI: 10.1186/1532-429x-10-62] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2008] [Accepted: 12/29/2008] [Indexed: 12/30/2022] Open
Abstract
The often touted advantages of MR guidance remain largely unrealized for cardiovascular interventional procedures in patients. Many procedures have been simulated in animal models. We argue these opportunities for clinical interventional MR will be met in the near future. This paper reviews technical and clinical considerations and offers advice on how to implement a clinical-grade interventional cardiovascular MR (iCMR) laboratory. We caution that this reflects our personal view of the "state of the art."
Collapse
Affiliation(s)
- Kanishka Ratnayaka
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
- Cardiology Division, Children's National Medical Center, Washington, DC, USA
| | - Anthony Z Faranesh
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Michael A Guttman
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Ozgur Kocaturk
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christina E Saikus
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert J Lederman
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
11
|
El-Sharkawy AMM, Qian D, Bottomley PA. The performance of interventional loopless MRI antennae at higher magnetic field strengths. Med Phys 2008; 35:1995-2006. [PMID: 18561676 DOI: 10.1118/1.2905027] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Interventional, "loopless antenna" MRI detectors are currently limited to 1.5 T. This study investigates whether loopless antennae offer signal-to-noise ratio (SNR) and field-of-view (FOV) advantages at higher fields, and whether device heating can be controlled within safe limits. The absolute SNR performance of loopless antennae from 0.5 to 5 T is investigated both analytically, using electromagnetic (EM) dipole antenna theory, and numerically with the EM method of moments, and found to vary almost quadratically with field strength depending on the medium's electrical properties, the noise being dominated by direct sample conduction losses. The prediction is confirmed by measurements of the absolute SNR of low-loss loopless antennae fabricated for 1.5, 3, and 4.7 T, immersed in physiologically comparable saline. Gains of 3.8 +/- 0.2- and 9.7 +/- 0.3-fold in SNR, and approximately 10- and 50-fold gains in the useful FOV area are observed at 3 and 4.7 T, respectively, compared to 1.5 T. Heat testing of a 3 T biocompatible nitinol-antenna fabricated with a redesigned decoupling circuit shows maximum heating of approximately 1 degrees C for MRI operating at high MRI exposure levels. Experiments in the rabbit aorta confirm the SNR and FOV advantages of the 3 T antenna versus an equivalent commercial 1.5 T device in vivo. This work is the first to study the performance of experimental internal MRI detectors above 1.5 T. The large SNR and FOV gains realized present a major opportunity for high-resolution imaging of vascular pathology and MRI-guided intervention.
Collapse
Affiliation(s)
- AbdEl-Monem M El-Sharkawy
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21287, USA
| | | | | |
Collapse
|
12
|
Kraitchman DL, Gilson WD, Lorenz CH. Stem cell therapy: MRI guidance and monitoring. J Magn Reson Imaging 2008; 27:299-310. [PMID: 18219684 DOI: 10.1002/jmri.21263] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
With the recent advances in magnetic resonance (MR) labeling of cellular therapeutics, it is natural that interventional MRI techniques for targeting would be developed. This review provides an overview of the current methods of stem cell labeling and the challenges that are created with respect to interventional MRI administration. In particular, stem cell therapies will require specialized, MR-compatible devices as well as integration of graphical user interfaces with pulse sequences designed for interactive, real-time delivery in many organs. Specific applications that are being developed will be reviewed as well as strategies for future translation to the clinical realm.
Collapse
Affiliation(s)
- Dara L Kraitchman
- Johns Hopkins University, School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD 21287, USA.
| | | | | |
Collapse
|
13
|
Wang Z, Lin JC, Mao W, Liu W, Smith MB, Collins CM. SAR and temperature: simulations and comparison to regulatory limits for MRI. J Magn Reson Imaging 2007; 26:437-41. [PMID: 17654736 PMCID: PMC4040525 DOI: 10.1002/jmri.20977] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To present and discuss numerical calculations of the specific absorption rate (SAR) and temperature in comparison to regulatory limits. While it is possible to monitor whole-body or whole-head average SAR and/or core body temperature during MRI in practice, this is not generally true for local SAR values or local temperatures throughout the body. While methods of calculation for SAR and temperature are constantly being refined, methods for interpreting results of these calculations in light of regulatory limits also warrant discussion. MATERIALS AND METHODS Numerical calculations of SAR and temperature for the human head in a volume coil for MRI at several different frequencies are presented. RESULTS Just as the field pattern changes with the frequency, so do the temperature distribution and the ratio of maximum local SAR (in 1-g or 10-g regions) to whole-head average SAR. In all of the cases studied here this ratio is far greater than that in the regulatory limits, indicating that existing limits on local SAR will be exceeded before limits on whole-body or whole-head average SAR are reached. CONCLUSION Calculations indicate that both SAR and temperature distributions vary greatly with B(1) field frequency, that temperature distributions do not always correlate well with SAR distributions, and that regulatory limits on local temperature may not be exceeded as readily as those on local SAR.
Collapse
Affiliation(s)
- Zhangwei Wang
- Center for NMR Research, Penn State College of Medicine, Hershey, Pennsylvania, USA
| | - James C. Lin
- Department of Electrical and Computer Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Weihua Mao
- Center for NMR Research, Penn State College of Medicine, Hershey, Pennsylvania, USA
| | - Wanzhan Liu
- Center for MR Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Michael B. Smith
- Center for NMR Research, Penn State College of Medicine, Hershey, Pennsylvania, USA
| | | |
Collapse
|
14
|
Measuring local RF heating in MRI: Simulating perfusion in a perfusionless phantom. J Magn Reson Imaging 2007; 26:1228-35. [DOI: 10.1002/jmri.21161] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
15
|
Rickers C, Kraitchman D, Fischer G, Kramer HH, Wilke N, Jerosch-Herold M. Cardiovascular interventional MR imaging: a new road for therapy and repair in the heart. Magn Reson Imaging Clin N Am 2005; 13:465-79. [PMID: 16084413 DOI: 10.1016/j.mric.2005.04.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Over the last 5 years, interventional MR imaging has been fertile ground for research. Real-time MR imaging, combined with recent advances in other MR imaging modalities such as perfusion imaging and intravascular imaging, has opened up new paths for cardiac therapy. The recent reports on cardiac stem cell therapy guided and monitored by MR imaging suggest that we are already seeing the establishment of an important role for cardiac MR imaging in cardiac restoration. The collaborative effort from a multidisciplinary team of basic biologists, engineers, and clinicians will refine stem cell incubation and labeling for MR-guided transcatheter endomyocardial injections, and this in turn may facilitate new studies in humans. Several groups have demonstrated in animal studies the feasibility of MR-guided catheter interventions for the treatment of congenital heart disease and arrythmia therapy. Hence, applications in humans remain the challenge for the next years. Although there have been first reports of cardiac catheterizations in humans by combined use of x-ray fluoroscopy and MR imaging, there are no reports in the literature suggesting that active tracking methods by MR imaging have been applied to humans. Safety issues (namely, heating of catheters and wires) hamper clinical use, particularly in infants and children. Current reports are promising that these limitations will be overcome in the near future and will eventually reduce x-ray usage during catheterization. In its current state, cardiac MR imaging offers a unique opportunity to investigate new therapeutic strategies for the treatment of congenital and acquired heart disease.
Collapse
Affiliation(s)
- Carsten Rickers
- Department of Pediatric Cardiology, University Hospital Schleswig-Holstein, Campus Kiel, Brunswiker Strasse 10, 24105 Kiel, Germany.
| | | | | | | | | | | |
Collapse
|
16
|
Atalar E. Radiofrequency safety for interventional MRI procedures. Acad Radiol 2005; 12:1149-57. [PMID: 16112515 DOI: 10.1016/j.acra.2005.06.007] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2005] [Revised: 06/08/2005] [Accepted: 06/08/2005] [Indexed: 11/30/2022]
|
17
|
McVeigh ER, Guttman MA, Kellman P, Raval AN, Lederman RJ. Real-time, Interactive MRI for cardiovascular interventions. Acad Radiol 2005; 12:1121-7. [PMID: 16112512 PMCID: PMC2169205 DOI: 10.1016/j.acra.2005.05.024] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2005] [Revised: 05/29/2005] [Accepted: 02/15/2005] [Indexed: 11/25/2022]
Affiliation(s)
- Elliot R McVeigh
- Laboratory of Cardiac Energetics, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room B1D416, Bethesda, MD 20892-106, USA.
| | | | | | | | | |
Collapse
|
18
|
Saeed M, Saloner D, Weber O, Martin A, Henk C, Higgins C. MRI in guiding and assessing intramyocardial therapy. Eur Radiol 2005; 15:851-63. [PMID: 15856250 DOI: 10.1007/s00330-004-2622-8] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2004] [Revised: 12/01/2004] [Accepted: 12/07/2004] [Indexed: 01/12/2023]
Abstract
Cardiovascular intervention, using MRI guidance, is challenging for clinical applications. Real-time imaging sequences with high spatial resolution are needed for monitoring intramyocardial delivery of drug, gene, or stem cell therapies. New generation MR scanners make local intramyocardial and vascular wall therapies feasible. Contrast-enhanced MRI is used for assessing myocardial ischemia, infarction, and scar tissue. Active (microcoils) and passive (T1 and T2* mechanisms) tracking methods have been used for visualization of endovascular catheters. Safety issues related to potential heating of endovascular devices is still a major obstacle for MRI-guided interventions. Fabrication of MRI-compatible interventional devices is limited. Noninvasive imaging strategies will be critical in defining spatial and temporal characteristics of angiogenesis and myocardial repair as well as in assessing the efficacy of new therapies in ischemic heart disease. MRI contrast media improve the capability of MRI by delineating the target and vascular tree. Labeling stem cells enables MRI to trace distribution, differentiation, and survival in myocardium and vascular wall. In the long term, MRI in guiding and assessing intramyocardial therapy may circumvent the limitations of peripherally administered cell therapy, X-ray angiography, and nuclear imaging. MRI represents a highly attractive discipline whose systematic development will foster the implementation of new cardiac and vascular therapies.
Collapse
Affiliation(s)
- M Saeed
- Department of Radiology, School of Medicine, University of California-San Francisco, 94143-0628, USA.
| | | | | | | | | | | |
Collapse
|
19
|
Luechinger R, Zeijlemaker VA, Pedersen EM, Mortensen P, Falk E, Duru F, Candinas R, Boesiger P. In vivo heating of pacemaker leads during magnetic resonance imaging. Eur Heart J 2004; 26:376-83; discussion 325-7. [PMID: 15618060 DOI: 10.1093/eurheartj/ehi009] [Citation(s) in RCA: 166] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS Magnetic resonance imaging (MRI) is well established as an important diagnostic tool in medicine. However, the presence of a cardiac pacemaker is usually regarded as a contraindication for MRI due to safety reasons. In this study, heating effects at the myocardium-pacemaker lead tip interface have been investigated in a chronic animal model during MRI at 1.5 Tesla. METHODS AND RESULTS Pacemaker leads with additional thermocouple wires as temperature sensors were implanted in nine animals. Temperature increases of up to 20 degrees C were measured during MRI of the heart. Significant impedance and minor stimulation threshold changes could be seen. However, pathology and histology could not clearly demonstrate heat-induced damage. CONCLUSIONS MRI may produce considerable heating at the lead tip. Changes of pacing parameters due to MRI could be seen in chronic experiments. Potential risk of tissue damage cannot be excluded even though no reproducible alterations at the histological level could be found.
Collapse
Affiliation(s)
- Roger Luechinger
- Institute of Biomedical Engineering, University and Swiss Federal Institute of Technology, Gloriastrasse 35, 8092 Zurich, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Armenean C, Perrin E, Armenean M, Beuf O, Pilleul F, Saint-Jalmes H. RF-induced temperature elevation along metallic wires in clinical magnetic resonance imaging: Influence of diameter and length. Magn Reson Med 2004; 52:1200-6. [PMID: 15508156 DOI: 10.1002/mrm.20246] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
With the development of interventional MRI, heating of biological tissues along the metallic wires in the MRI scanner has become an important issue. To assess thermal response to RF exposure during MRI, we studied the temperature elevation near nonmagnetic metallic wires. All tests were performed on a 1.5 T clinical scanner. Four experiments were conducted to investigate the effects of the wire diameter, the excitation flip angle, the temperature distribution along the wire, and the wire length. Electromagnetic simulations of the experimental setup were made with the use of commercial method of moments (MoM) software and numerical simulations of Hallen's equations. Comparisons between measured and calculated values of the electric field are presented. This study demonstrates that 1) temperature decreases with the diameter of the wire,2) temperature increases quadratically with the excitation flip angle, 3) heating occurs not only at the tip but also along the wire, and 4) the heating peaks are not obtained for the classical resonant length multiple of lambda/4 (where lambda is the RF field wavelength). In addition, significant and rapid heating increases were observed in the close vicinity of the wire.
Collapse
Affiliation(s)
- Cristina Armenean
- Laboratoire de Résonance Magnétique Nucléaire-Méthodologie et Instrumentation en Biophysique, UMR 5012 CNRS UCBL CPE, Université Claude Bernard-Lyon I, France
| | | | | | | | | | | |
Collapse
|
21
|
Dick AJ, Guttman MA, Raman VK, Peters DC, Pessanha BS, Hill JM, Smith S, Scott G, McVeigh ER, Lederman RJ. Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in Swine. Circulation 2003; 108:2899-904. [PMID: 14656911 PMCID: PMC1325104 DOI: 10.1161/01.cir.0000095790.28368.f9] [Citation(s) in RCA: 184] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
BACKGROUND The local environment of delivered mesenchymal stem cells (MSCs) may affect their ultimate phenotype. MR fluoroscopy has the potential to guide intramyocardial MSC injection to desirable targets, such as the border between infarcted and normal tissue. We tested the ability to (1) identify infarcts, (2) navigate injection catheters to preselected targets, (3) inject safely even into fresh infarcts, and (4) confirm injection success immediately. METHODS AND RESULTS A 1.5-T MRI scanner was customized for interventional use, with rapid imaging, independent color highlighting of catheter channels, multiple-slice 3D rendering, catheter-only viewing mode, and infarct-enhanced imaging. MRI receiver coils were incorporated into guiding catheters and injection needles. These devices were tested for heating and used for targeted MSC delivery. In infarcted pigs, myocardium was targeted by MR fluoroscopy. Infarct-enhanced imaging included both saturation preparation MRI after intravenous gadolinium and wall motion. Porcine MSCs were MRI-labeled with iron-fluorescent particles. Catheter navigation and multiple cell injections were performed entirely with MR fluoroscopy at 8 frames/s with 1.7x3.3x8-mm voxels. Infarct-enhanced MR fluoroscopy permitted excellent delineation of infarct borders. All injections were safely and successfully delivered to their preselected targets, including infarct borders. Iron-fluorescent particle-labeled MSCs were readily visible on delivery in vivo and post mortem. CONCLUSIONS Precise targeted delivery of potentially regenerative cellular treatments to recent myocardial infarction borders is feasible with an MR catheter delivery system. MR fluoroscopy permits visualization of catheter navigation, myocardial function, infarct borders, and labeled cells after injection.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | - Robert J. Lederman
- Correspondence to Robert J. Lederman, MD, Cardiovascular Branch, Clinical Research Program, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD 20892-1538. E-mail
| |
Collapse
|
22
|
Abstract
Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed.
Collapse
Affiliation(s)
- L W Bartels
- Department of Radiology, Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, Room E.01.335, 3584 CX Utrecht, The Netherlands.
| | | |
Collapse
|
23
|
Serfaty JM, Yang X, Foo TK, Kumar A, Derbyshire A, Atalar E. MRI-guided coronary catheterization and PTCA: A feasibility study on a dog model. Magn Reson Med 2003; 49:258-63. [PMID: 12541245 DOI: 10.1002/mrm.10393] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The aim of this work was to demonstrate the feasibility of MRI-guided coronary artery catheterization and intervention in a dog model. Experiments were performed on 10 healthy dogs. A 9F introducer sheath was placed through a right carotid artery cutdown. A prototype 0.014-inch coronary MRI guidewire, a prototype 7 French MRI-guiding catheter, and two flexible surface coils were connected to a GE 1.5 T CV/i scanner for simultaneous visualization of the guidewire, guiding catheter, and chest anatomy. Images were displayed in real time on an in-room monitor. A nongated, single-slice fast gradient-echo sequence was used to obtain real-time images of the catheters and background anatomy during the intervention. Fifteen selective catheterizations were attempted in the coronary arteries, and all were successful. Selective injection of diluted gadolinium into the MRI-guiding catheter provided dynamic 2D projection coronary angiography in all cases, confirming successful catheterization. Percutaneous transluminal coronary angioplasty (PTCA) was attempted after two catheterizations, and all attempts were successful. Inflation of the balloon angioplasty catheter was performed successfully in the left anterior and circumflex arteries. Our results indicate that coronary artery catheterization and intracoronary balloon angioplasty are feasible with MRI guidance only. MRI guidance may be used as an alternative to X-ray guidance in coronary artery interventions in the future.
Collapse
|
24
|
Buecker A, Adam GB, Neuerburg JM, Kinzel S, Glowinski A, Schaeffter T, Rasche V, van Vaals JJ, Guenther RW. Simultaneous real-time visualization of the catheter tip and vascular anatomy for MR-guided PTA of iliac arteries in an animal model. J Magn Reson Imaging 2002; 16:201-8. [PMID: 12203769 DOI: 10.1002/jmri.10148] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To examine the feasibility of simultaneous MR real-time active tip tracking and near real-time depiction of the vascular anatomy for percutaneous angioplasty of iliac arteries under MR guidance. MATERIALS AND METHODS Nine surgically created stenoses of external iliac arteries in pigs were dilated with MR-compatible balloon catheters (Cordis, Roden, The Netherlands). These catheters were equipped with a microcoil for active tracking of the catheter tip with an in-plane update rate of 10 positions per second. The procedures were performed on an interventional 1.5 T Gyroscan ACS-NT scanner (Philips, Best, The Netherlands). Real-time calculation of images acquired by radial k-space filling was performed on a specially designed backprojector exploiting the sliding window reconstruction technique (Philips Research Laboratories, Hamburg, Germany). The image update rate was 20 frames per second using a radial gradient-echo technique (TR = 12 msec, TE = 3.3 msec, 300 radials). MR angiography and X-ray digital subtraction angiography on the X-ray system positioned in-line next to the interventional MR system served as control for the angioplasty results. RESULTS Real-time guidance and positioning of the balloon catheters was possible. The actual position of the catheter tip was indicated in the MR images without any time delay for the reconstruction of the anatomical MR images, which were updated with a rate of 20 frames per second. This yielded a combination of a roadmap and fluoroscopy image, in which the catheter position and the anatomical background image both were continuously updated in real time. Six out of nine stenoses were successfully dilated. The effects of the angioplasty could be visualized by the real-time MR technique, as was proven by X-ray digital subtraction angiography. CONCLUSION Active tip tracking simultaneous with MRI of the vascular anatomy-both in real time-is possible with the applied technique, enabling MR-guided percutaneous dilatation (PTA) of iliac arteries.
Collapse
Affiliation(s)
- Arno Buecker
- Clinic of Diagnostic Radiology, University of Technology Aachen, Aachen, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Lederman RJ, Guttman MA, Peters DC, Thompson RB, Sorger JM, Dick AJ, Raman VK, McVeigh ER. Catheter-based endomyocardial injection with real-time magnetic resonance imaging. Circulation 2002; 105:1282-4. [PMID: 11901036 PMCID: PMC1317571 DOI: 10.1161/01.cir.0000012425.71261.fc] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND We tested the feasibility of targeted left ventricular (LV) mural injection using real-time MRI (rtMRI). METHODS AND RESULTS A 1.5T MRI scanner was customized with a fast reconstruction engine, transfemoral guiding catheter-receiver coil (GCC), MRI-compatible needle, and tableside consoles. Commercial real-time imaging software was customized to facilitate catheter navigation and visualization of injections at 4 completely refreshed frames per second. The aorta was traversed and the left ventricular cavity was entered under direct rtMRI guidance. Pigs underwent multiple injections with dilute gadolinium-DTPA. All myocardial segments were readily accessed. The active GCC and the passive Stiletto needle injector were readily visualized. More than 50 endomyocardial injections were performed with the aid of rtMRI; 81% were successful with this first-generation prototype. CONCLUSION Percutaneous endomyocardial drug delivery is feasible with the aid of rtMRI, which permits precise 3-dimensional localization of injection within the LV wall.
Collapse
Affiliation(s)
- Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Md 20892-1061, USA.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
|
27
|
Abstract
Current safety regulations for local radiofrequency (rf) heating, developed for externally positioned rf coils, may not be suitable for internal rf coils that are being increasingly used in interventional MRI. This work presents a two-step model for rf heating in an interventional MRI setting: (1) the spatial distribution of power in the sample from the rf pulse (Maxwell's equations); and (2) the transformation of that power to temperature change according to thermal conduction and tissue perfusion (tissue bioheat equation). The tissue bioheat equation is approximated as a linear, shift-invariant system in the case of local rf heating and is fully characterized by its Green's function. Expected temperature distributions are calculated by convolving (averaging) transmit coil specific absorption rate (SAR) distributions with the Green's function. When the input SAR distribution is relatively slowly varying in space, as is the case with excitation by external rf coils, the choice of averaging methods makes virtually no difference on the expected heating as measured by temperature change (deltaT). However, for highly localized SAR distributions, such as those encountered with internal coils in interventional MRI, the Green's function method predicts heating that is significantly different from the averaging method in current regulations. In our opinion, the Green's function method is a better predictor since it is based on a physiological model. The Green's function also elicits a time constant and scaling factor between SAR and deltaT that are both functions of the tissue perfusion rate. This emphasizes the critical importance of perfusion in the heating model. The assumptions made in this model are only valid for local rf heating and should not be applied to whole body heating.
Collapse
Affiliation(s)
- C J Yeung
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, USA
| | | |