Kilbride BF, Narsinh KH, Jordan CD, Mueller K, Moore T, Martin AJ, Wilson MW, Hetts SW. MRI-guided endovascular intervention: current methods and future potential. Expert Rev Med Devices 2022; 19:763-778. [PMID: 36373162 PMCID: PMC9869980 DOI: 10.1080/17434440.2022.2141110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 10/25/2022] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Image-guided endovascular interventions, performed using the insertion and navigation of catheters through the vasculature, have been increasing in number over the years, as minimally invasive procedures continue to replace invasive surgical procedures. Such endovascular interventions are almost exclusively performed under x-ray fluoroscopy, which has the best spatial and temporal resolution of all clinical imaging modalities. Magnetic resonance imaging (MRI) offers unique advantages and could be an attractive alternative to conventional x-ray guidance, but also brings with it distinctive challenges. AREAS COVERED In this review, the benefits and limitations of MRI-guided endovascular interventions are addressed, systems and devices for guiding such interventions are summarized, and clinical applications are discussed. EXPERT OPINION MRI-guided endovascular interventions are still relatively new to the interventional radiology field, since significant technical hurdles remain to justify significant costs and demonstrate safety, design, and robustness. Clinical applications of MRI-guided interventions are promising but their full potential may not be realized until proper tools designed to function in the MRI environment are available. Translational research and further preclinical studies are needed before MRI-guided interventions will be practical in a clinical interventional setting.
Collapse
Affiliation(s)
- Bridget F. Kilbride
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Kazim H. Narsinh
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | | | | | - Teri Moore
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Alastair J. Martin
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Mark W. Wilson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Steven W. Hetts
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| |
Collapse
|
2
|
Heidt T, Reiss S, Krafft AJ, Özen AC, Lottner T, Hehrlein C, Galmbacher R, Kayser G, Hilgendorf I, Stachon P, Wolf D, Zirlik A, Düring K, Zehender M, Meckel S, von Elverfeldt D, Bode C, Bock M, von Zur Mühlen C. Real-time magnetic resonance imaging - guided coronary intervention in a porcine model. Sci Rep 2019; 9:8663. [PMID: 31209241 PMCID: PMC6572773 DOI: 10.1038/s41598-019-45154-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 06/03/2019] [Indexed: 11/28/2022] Open
Abstract
X-ray fluoroscopy is the gold standard for coronary diagnostics and intervention. Magnetic resonance imaging is a radiation-free alternative to x-ray with excellent soft tissue contrast in arbitrary slice orientation. Here, we assessed real-time MRI-guided coronary interventions from femoral access using newly designed MRI technologies. Six Goettingen minipigs were used to investigate coronary intervention using real-time MRI. Catheters were custom-designed and equipped with an active receive tip-coil to improve visibility and navigation capabilities. Using modified standard clinical 5 F catheters, intubation of the left coronary ostium was successful in all animals. For the purpose of MR-guided coronary interventions, a custom-designed 8 F catheter was used. In spite of the large catheter size, and therefore limited steerability, intubation of the left coronary ostium was successful in 3 of 6 animals within seconds. Thereafter, real-time guided implantation of a non-metallic vascular scaffold into coronary arteries was possible. This study demonstrates that real-time MRI-guided coronary catheterization and intervention via femoral access is possible without the use of any contrast agents or radiation, including placement of non-metallic vascular scaffolds into coronary arteries. Further development, especially in catheter and guidewire technology, will be required to drive forward routine MR-guided coronary interventions as an alternative to x-ray fluoroscopy.
Collapse
Affiliation(s)
- Timo Heidt
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany.
| | - Simon Reiss
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Axel J Krafft
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Ali Caglar Özen
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Thomas Lottner
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Christoph Hehrlein
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Roland Galmbacher
- Department of Experimental Anesthesiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Gian Kayser
- Department of Pathology, Institute of Surgical Pathology, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Ingo Hilgendorf
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Peter Stachon
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Dennis Wolf
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Andreas Zirlik
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | | | - Manfred Zehender
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Stephan Meckel
- Department of Neuroradiology, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Dominik von Elverfeldt
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Christoph Bode
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Michael Bock
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Constantin von Zur Mühlen
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| |
Collapse
|
3
|
Zhang X, Martin A, Jordan C, Lillaney P, Losey A, Pang Y, Hu J, Wilson M, Cooke D, Hetts SW. Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging. Quant Imaging Med Surg 2017; 7:187-194. [PMID: 28516044 DOI: 10.21037/qims.2016.12.05] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND It is technically challenging to design compact yet sensitive miniature catheter radio frequency (RF) coils for endovascular interventional MR imaging. METHODS In this work, a new design method for catheter RF coils is proposed based on the coaxial transmission line resonator (TLR) technique. Due to its distributed circuit, the TLR catheter coil does not need any lumped capacitors to support its resonance, which simplifies the practical design and construction and provides a straightforward technique for designing miniature catheter-mounted imaging coils that are appropriate for interventional neurovascular procedures. The outer conductor of the TLR serves as an RF shield, which prevents electromagnetic energy loss, and improves coil Q factors. It also minimizes interaction with surrounding tissues and signal losses along the catheter coil. To investigate the technique, a prototype catheter coil was built using the proposed coaxial TLR technique and evaluated with standard RF testing and measurement methods and MR imaging experiments. Numerical simulation was carried out to assess the RF electromagnetic field behavior of the proposed TLR catheter coil and the conventional lumped-element catheter coil. RESULTS The proposed TLR catheter coil was successfully tuned to 64 MHz for proton imaging at 1.5 T. B1 fields were numerically calculated, showing improved magnetic field intensity of the TLR catheter coil over the conventional lumped-element catheter coil. MR images were acquired from a dedicated vascular phantom using the TLR catheter coil and also the system body coil. The TLR catheter coil is able to provide a significant signal-to-noise ratio (SNR) increase (a factor of 200 to 300) over its imaging volume relative to the body coil. CONCLUSIONS Catheter imaging RF coil design using the proposed coaxial TLR technique is feasible and advantageous in endovascular interventional MR imaging applications.
Collapse
Affiliation(s)
- Xiaoliang Zhang
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.,UC Berkeley/UCSF Joint Bioengineering Program, University of California, Berkeley, San Francisco, CA, USA
| | - Alastair Martin
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Caroline Jordan
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Prasheel Lillaney
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Aaron Losey
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Yong Pang
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Jeffrey Hu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Mark Wilson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Daniel Cooke
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Steven W Hetts
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| |
Collapse
|
4
|
Magnetic Resonance-Guided Passive Catheter Tracking for Endovascular Therapy. Magn Reson Imaging Clin N Am 2015; 23:591-605. [PMID: 26499277 DOI: 10.1016/j.mric.2015.05.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The use of MR guidance for endovascular intervention is appealing because of its lack of ionizing radiation, high-contrast visualization of vessel walls and adjacent soft tissues, multiplanar capabilities, and potential to incorporate functional information such as flow, fluid dynamics, perfusion, and cardiac motion. This review highlights state-of-the-art imaging techniques and hardware used for passive tracking of endovascular devices in interventional MR imaging, including negative contrast, passive contrast, nonproton multispectral, and direct current techniques. The advantages and disadvantages of passive tracking relative to active tracking are also summarized.
Collapse
|
5
|
Pandey S, Hakky M, Kwak E, Jara H, Geyer CA, Erbay SH. Application of basic principles of physics to head and neck MR angiography: troubleshooting for artifacts. Radiographics 2014; 33:E113-23. [PMID: 23674781 DOI: 10.1148/rg.333125148] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Neurovascular imaging studies are routinely used for the assessment of headaches and changes in mental status, stroke workup, and evaluation of the arteriovenous structures of the head and neck. These imaging studies are being performed with greater frequency as the aging population continues to increase. Magnetic resonance (MR) angiographic imaging techniques are helpful in this setting. However, mastering these techniques requires an in-depth understanding of the basic principles of physics, complex flow patterns, and the correlation of MR angiographic findings with conventional MR imaging findings. More than one imaging technique may be used to solve difficult cases, with each technique contributing unique information. Unfortunately, incorporating findings obtained with multiple imaging modalities may add to the diagnostic challenge. To ensure diagnostic accuracy, it is essential that the radiologist carefully evaluate the details provided by these modalities in light of basic physics principles, the fundamentals of various imaging techniques, and common neurovascular imaging pitfalls.
Collapse
Affiliation(s)
- Shilpa Pandey
- Department of Radiology, Tufts Medical Center, Boston, MA, USA
| | | | | | | | | | | |
Collapse
|
6
|
Qin L, Schmidt EJ, Tse ZTH, Santos J, Hoge WS, Tempany-Afdhal C, Butts-Pauly K, Dumoulin CL. Prospective motion correction using tracking coils. Magn Reson Med 2013; 69:749-59. [PMID: 22565377 PMCID: PMC3416927 DOI: 10.1002/mrm.24310] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2011] [Revised: 03/31/2012] [Accepted: 04/04/2012] [Indexed: 11/10/2022]
Abstract
Intracavity imaging coils provide higher signal-to-noise than surface coils and have the potential to provide higher spatial resolution in shorter acquisition times. However, images from these coils suffer from physiologically induced motion artifacts, as both the anatomy and the coils move during image acquisition. We developed prospective motion-correction techniques for intracavity imaging using an array of tracking coils. The system had <50 ms latency between tracking and imaging, so that the images from the intracavity coil were acquired in a frame of reference defined by the tracking array rather than by the system's gradient coils. Two-dimensional gradient-recalled and three-dimensional electrocardiogram-gated inversion-recovery-fast-gradient-echo sequences were tested with prospective motion correction using ex vivo hearts placed on a moving platform simulating both respiratory and cardiac motion. Human abdominal tests were subsequently conducted. The tracking array provided a positional accuracy of 0.7 ± 0.5 mm, 0.6 ± 0.4 mm, and 0.1 ± 0.1 mm along the X, Y, and Z directions at a rate of 20 frames-per-second. The ex vivo and human experiments showed significant image quality improvements for both in-plane and through-plane motion correction, which although not performed in intracavity imaging, demonstrates the feasibility of implementing such a motion-correction system in a future design of combined tracking and intracavity coil.
Collapse
Affiliation(s)
- Lei Qin
- Department of Radiology, Dana-Farber Cancer Institute, Boston, Massachusetts 02215, USA.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Tadayyon H, Vikal S, Gill S, Lasso A, Fichtinger G. MRI-guided prostate motion tracking by means of multislice-to-volume registration. ACTA ACUST UNITED AC 2010; 7625:76252V. [PMID: 21132081 DOI: 10.1117/12.844454] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
We developed an algorithm for tracking prostate motion during MRI-guided prostatic needle placement, with the primary application in prostate biopsy. Our algorithm has been tested on simulated patient and phantom data. The algorithm features a robust automatic restart and a 12-core biopsy error validation scheme. Simulation tests were performed on four patient MRI pre-operative volumes. Three orthogonal slices were extracted from the pre-operative volume to simulate the intra-operative volume and a volume of interest was defined to isolate the prostate. Phantom tests used six datasets, each representing the phantom at a known perturbed position. These volumes were registered to their corresponding reference volume (the phantom at its home position). Convergence tests on the phantom data showed that the algorithm demonstrated accurate results at 100% confidence level for initial misalignments of less than 5mm and at 73% confidence level for initial misalignments less than 10mm. Our algorithm converged in 95% of the cases for the simulated patient data with 0.66mm error and the six phantom registration tests resulted in 1.64mm error.
Collapse
Affiliation(s)
- Hadi Tadayyon
- Dept. of Electrical & Computer Engineering, Queen's University, Kingston, Canada K7L 3N6
| | | | | | | | | |
Collapse
|
8
|
Schmidt EJ, Yoneyama R, Dumoulin CL, Darrow RD, Klein E, Kiruluta AJ, Hayase M. 3D coronary motion tracking in swine models with MR tracking catheters. J Magn Reson Imaging 2009; 29:86-98. [DOI: 10.1002/jmri.21468] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
9
|
Kos S, Huegli R, Bongartz GM, Jacob AL, Bilecen D. MR-guided endovascular interventions: a comprehensive review on techniques and applications. Eur Radiol 2007; 18:645-57. [PMID: 18071710 DOI: 10.1007/s00330-007-0818-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2007] [Revised: 10/01/2007] [Accepted: 10/30/2007] [Indexed: 10/22/2022]
Abstract
The magnetic resonance (MR) guidance of endovascular interventions is probably one of the greatest challenges of clinical MR research. MR angiography is not only an imaging tool for the vasculature but can also simultaneously depict high tissue contrast, including the differentiation of the vascular wall and perivascular tissues, as well as vascular function. Several hurdles had to be overcome to allow MR guidance for endovascular interventions. MR hardware and sequence design had to be developed to achieve acceptable patient access and to allow real-time or near real-time imaging. The development of interventional devices, both applicable and safe for MR imaging (MRI), was also mandatory. The subject of this review is to summarize the latest developments in real-time MRI hardware, MRI, visualization tools, interventional devices, endovascular tracking techniques, actual applications and safety issues.
Collapse
Affiliation(s)
- Sebastian Kos
- Institute of Radiology, Division of Interventional Radiology, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland.
| | | | | | | | | |
Collapse
|
10
|
Eggebrecht H, Heusch G, Erbel R, Ladd ME, Quick HH. Real-time vascular interventional magnetic resonance imaging. Basic Res Cardiol 2006; 102:1-8. [PMID: 17006635 DOI: 10.1007/s00395-006-0624-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2006] [Accepted: 08/14/2006] [Indexed: 11/26/2022]
Abstract
Endovascular stent-graft placement is emerging as a promising alternative to medical and surgical treatment of patients with diseases of the descending thoracic and abdominal aorta. Precise placement of the stentgraft, which is currently performed under x-ray control, remains, however, challenging as there are several shortcomings to fluoroscopic guidance beyond that related to the harmful effect of radiation exposure and nephrotoxic contrast media. While transesophageal echocardiography and intravascular ultrasound have been used as adjunct imaging modalities during endovascular stent-graft procedures to overcome the limitations of angiography, these techniques have not mitigated the need for fluoroscopy. Magnetic resonance imaging (MRI) guidance of vascular interventional procedures offers several potential advantages over fluoroscopy-guided techniques, including image acquisition in any desired orientation, superior 3D soft-tissue contrast with simultaneous visualization of the interventional device, absence of ionizing radiation, and avoidance of nephrotoxic contrast media. Magnetic resonance imaging is often used for pre-operative diagnosis of aortic disease and can provide all relevant information for the planning of endovascular stent-graft procedures as well as for accurate and immediate post-interventional evaluation. However, visualization of interventional instruments by MRI has proven to be the chief obstacle. This article will review current approaches that have been developed for depicting vascular instruments by MRI and will also discuss the first experimental experiences with MRI-guided endovascular stent-graft placement in a swine model of aortic dissection.
Collapse
Affiliation(s)
- Holger Eggebrecht
- Klinik für Kardiologie, Westdeutsches Herzzentrum Essen, Klinikum der Universität Duisburg-Essen, Essen, Germany.
| | | | | | | | | |
Collapse
|
11
|
Elgort DR, Hillenbrand CM, Zhang S, Wong EY, Rafie S, Lewin JS, Duerk JL. Image-guided and -monitored renal artery stenting using only MRI. J Magn Reson Imaging 2006; 23:619-27. [PMID: 16555228 DOI: 10.1002/jmri.20554] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To demonstrate the ability of a unique interventional MR system to be used safely and effectively as the only imaging modality for all phases of MR-guided stent-supported angioplasty. MATERIALS AND METHODS An experimental disease model of renal stenosis was created in six pigs. An interventional MR system, which employed previously reported tools for real-time catheter tracking with automated scan-plane positioning, adaptive image parameters, and radial true-FISP imaging with steady-state precession (True-FISP) imaging coupled with a high-speed reconstruction technique, was then used to guide all phases of the intervention, including: guidewire and catheter insertion, stent deployment, and confirmation of therapeutic success. Pre- and postprocedural X-ray imaging was used as a gold standard to validate the experimental results. RESULTS All of the stent-supported angioplasty interventions were a technical success and were performed without complications. The average postoperative residual stenosis was 14.9%. The image guidance enabled the stents to be deployed with an accuracy of 0.98 +/- 0.69 mm. Additionally, using this interventional MRI system to guide renal artery stenting significantly reduces the procedure time, as compared to using X-ray fluoroscopy. CONCLUSION This study has clearly demonstrated the first successful treatment of renal artery stenting in an experimental animal model solely under MRI guidance and monitoring.
Collapse
Affiliation(s)
- Daniel R Elgort
- Department of Radiology, University Hospitals of Cleveland, Cleveland, Ohio 044106, USA
| | | | | | | | | | | | | |
Collapse
|
12
|
Mekle R, Hofmann E, Scheffler K, Bilecen D. A polymer-based MR-compatible guidewire: a study to explore new prospects for interventional peripheral magnetic resonance angiography (ipMRA). J Magn Reson Imaging 2006; 23:145-55. [PMID: 16374877 DOI: 10.1002/jmri.20486] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To introduce a newly developed polymer-based and magnetic resonance (MR)-compatible guidewire and to explore its capabilities with respect to interventional peripheral magnetic resonance angiography (ipMRA) in a flow phantom. MATERIALS AND METHODS The guidewire is based on a polyetheretherketone (PEEK) polymer core, and small iron particles are embedded in its coating. A passive device tracking technique was designed utilizing a susceptibility artifact induced by the wire in images acquired with a balanced steady-state free precession (b-SSFP) sequence using small flip angles. The position of the guidewire tip was determined from image intensity maxima and overlayed onto a roadmap in near real-time. Guidewire tracking and balloon angioplasty of an artificial stenosis were attempted in two configurations of a flow phantom. RESULTS Successful passive guidewire tracking was performed for all phantom configurations. Robustness and accuracy of the tracking technique were sufficient for phantom studies. A balloon catheter was placed into the stenosis using the guidewire under complete MR guidance, and subsequent balloon angioplasty yielded improved flow conditions. CONCLUSION The new guidewire is well-suited for clinical application due to an absence of the risk of core fracture and its atraumatic flexible tip. It opens novel prospects for the realization of ipMRA in humans that need to be explored in further studies.
Collapse
Affiliation(s)
- Ralf Mekle
- MR-Physics, University of Basel/University Hospital, Basel, Switzerland.
| | | | | | | |
Collapse
|
13
|
Peeters JM, Seppenwoolde JH, Bartels LW, Bakker CJG. Development and testing of passive tracking markers for different field strengths and tracking speeds. Phys Med Biol 2006; 51:N127-37. [PMID: 16510948 DOI: 10.1088/0031-9155/51/6/n04] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Susceptibility markers for passive tracking need to be small in order to maintain the shape and mechanical properties of the endovascular device. Nevertheless, they also must have a high magnetic moment to induce an adequate artefact at a variety of scan techniques, tracking speeds and, preferably, field strengths. Paramagnetic markers do not satisfy all of these requirements. Ferro- and ferrimagnetic materials were therefore investigated with a vibrating sample magnetometer and compared with the strongly paramagnetic dysprosium oxide. Results indicated that the magnetic behaviour of stainless steel type AISI 410 corresponds the best with ideal marker properties. Markers with different magnetic moments were constructed and tested in in vitro and in vivo experiments. The appearance of the corresponding artefacts was field strength independent above magnetic saturation of 1.5 T. Generally, the contrast-to-noise ratio decreased at increasing tracking speed and decreasing magnetic moment. Device depiction was most consistent at a frame rate of 20 frames per second.
Collapse
Affiliation(s)
- J M Peeters
- Image Sciences Institute, Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, RM Q.0S.459, 3584 CA Utrecht, The Netherlands
| | | | | | | |
Collapse
|
14
|
Seppenwoolde JH, Bartels LW, van der Weide R, Nijsen JFW, van het Schip AD, Bakker CJG. Fully MR-guided hepatic artery catheterization for selective drug delivery: A feasibility study in pigs. J Magn Reson Imaging 2006; 23:123-9. [PMID: 16374883 DOI: 10.1002/jmri.20479] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To demonstrate the feasibility of hepatic catheterization for selective delivery of therapeutic agents using a clinical MRI scanner for real-time image guidance. MATERIALS AND METHODS Experiments were performed in three domestic pigs (70-80 kg) using a clinical 1.5-T MR scanner. After abdominal three-dimensional contrast-enhanced MR angiography (3D-CE-MRA) was performed, endovascular devices with susceptibility markers were tracked with passive tracking techniques. Catheters were maneuvered into the primary and secondary hepatic arteries. Selective catheterization was verified using selective time-resolved CE angiography. Paramagnetic microspheres were administered to a different region for each liver. The resulting biodistributions were investigated using MR images. RESULTS Successful selective hepatic catheterization was repeatedly demonstrated using passive tracking techniques. 3D-CE-MRA significantly aided the interventional procedure by showing the vascular anatomy, and maximum-intensity projections (MIPs) were used as roadmaps during the interventions. In all cases, microspheres were successfully delivered to the selected regions. The catheters were visualized at a maximum frame rate of five frames per second, allowing a good depiction of the devices and a reliable catheterization of the hepatic arteries. CONCLUSION Fully MR-guided real-time navigation of endovascular devices permits complex procedures such as selective intra-arterial delivery of therapeutic agents to parts of the liver.
Collapse
Affiliation(s)
- Jan-Henry Seppenwoolde
- Image Sciences Institute, Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands.
| | | | | | | | | | | |
Collapse
|
15
|
Eggebrecht H, Zenge M, Ladd ME, Erbel R, Quick HH. In Vitro Evaluation of Current Thoracic Aortic Stent-Grafts for Real-time MR-Guided Placement. J Endovasc Ther 2006; 13:62-71. [PMID: 16445325 DOI: 10.1583/05-1707.1] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To systematically evaluate the magnetic resonance imaging (MRI) characteristics of current thoracic aortic stent-graft devices before, during, and after in vitro deployment as a step toward real-time MRI-guided stent placement. METHODS Six stent-graft devices used for thoracic aortic repair were examined in a dedicated phantom model using a 1.5-T MRI scanner. First, the delivery systems with the mounted stent-graft were examined using real-time fast imaging with steady-state precession (TrueFISP) with Cartesian and radial k-space filling. TrueFISP imaging was subsequently used for real-time monitoring of stent-graft expansion. The deployed stent-grafts were then examined in a water bath containing gadolinium (1:40) with high-resolution T1-weighted 3D fast low-angle shot (FLASH) sequences. The images were analyzed for artifacts, radiofrequency caging effects, and device visualization quality. RESULTS Three delivery systems with mounted stent-grafts did not contain ferromagnetic elements and were well visualized. Imaging with radial k-space filling showed fewer artifacts than Cartesian imaging. Movement of the delivery system and stent-graft expansion of these devices were successfully demonstrated at a rate of up to 6 frames per second. Evaluation of the expanded stent-grafts revealed only minor susceptibility artifacts without relevant signal attenuation in the stent-graft lumen for 5 nitinol-based stent-grafts. Only a stainless steel-based stent-graft was associated with severe artifacts, thwarting visualization of its lumen or surroundings. CONCLUSION The present study shows that 3 nitinol-based thoracic stent-graft devices are potentially suited for real-time MRI-guided placement with respect to both the delivery system and the stent-graft itself. These observations provide the basis for the evaluation of MRI-guided stent-graft placement in vivo.
Collapse
Affiliation(s)
- Holger Eggebrecht
- Department of Cardiology, West German Heart Center Essen, University of Duisburg-Essen, Germany.
| | | | | | | | | |
Collapse
|
16
|
Eggebrecht H, Kühl H, Kaiser GM, Aker S, Zenge MO, Stock F, Breuckmann F, Grabellus F, Ladd ME, Mehta RH, Erbel R, Quick HH. Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection. Eur Heart J 2006; 27:613-20. [PMID: 16431874 DOI: 10.1093/eurheartj/ehi732] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS To evaluate the pre-clinical feasibility of real-time magnetic resonance imaging (rtMRI) to guide stent-graft placement for experimental aortic dissection (AD) and to alleviate disadvantages of ionising radiation and nephrotoxic contrast media. Endovascular stent-graft placement for thoracic aortic disease is usually performed under X-ray guidance. The feasibility of rtMRI-guided stent-graft placement is currently not known. METHODS AND RESULTS By using a catheter-based technique, dissections of the descending thoracic aorta were successfully created in eight domestic pigs. Subsequent implantation of commercially available, nitinol-based stent-grafts was performed entirely under rtMRI guidance. By pre-interventional MRI, the mean minimal true-lumen diameter was 0.9 (0.825-0.975) cm. rtMRI permitted not only the successful and safe device navigation within the true lumen from the iliac arteries to the thoracic aorta, but also the precise positioning and deployment of the stent-graft and safe withdrawal of the delivery catheter in seven of eight pigs. This was achieved without any other complications. After the stent-graft placement, MRI demonstrated complete obliteration of the false lumen, which was confirmed at autopsy. All stent-grafts were well expanded resulting in an increase in the size of the true-lumen diameter to 2.05 (1.925-2.1) cm (P=0.066 vs. baseline). CONCLUSION In experimental AD, rtMRI-guided endovascular stent-graft placement is feasible and safe and has the potential for mitigating radiation and contrast-related side effects. Additionally, it allows not only pre-interventional diagnosis and detailed anatomic diagnosis, but also permits immediate post-interventional, anatomical, and functional delineation of procedure success that may serve as a baseline for future comparison during follow-up.
Collapse
|
17
|
Froger CL, Duijm LEM, Liem YS, Tielbeek AV, Donkers-van Rossum AB, Douwes-Draaijer P, Cuypers PWM, Buth J, van den Bosch HCM. Stenosis detection with MR angiography and digital subtraction angiography in dysfunctional hemodialysis access fistulas and grafts. Radiology 2005; 234:284-91. [PMID: 15618386 DOI: 10.1148/radiol.2341031859] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively assess three-dimensional contrast material-enhanced magnetic resonance (MR) angiography for stenosis depiction in malfunctioning hemodialysis arteriovenous fistulas (AVFs) and grafts (AVGs), as compared with digital subtraction angiography (DSA). MATERIALS AND METHODS Ethical review board approval and written informed consent were obtained. MR angiography and DSA were performed in 51 dysfunctional hemodialysis fistulas and grafts in 48 consecutive patients. Vascular tree of accesses was divided into between three and eight segments depending on access type (AVF or AVG) and length of venous outflow. Images obtained with MR and DSA were interpreted by two MR radiologists and two interventional radiologists, respectively, who were blinded to information from each other and other studies. DSA was reference standard for stenosis detection. Sensitivity, specificity, and predictive values with 95% confidence intervals (CIs) of contrast-enhanced MR in detection of vascular segments containing hemodynamically significant (> or =50%) stenosis were calculated. Linear-weighted kappa statistic was calculated for contrast-enhanced MR and DSA to determine interobserver agreement regarding stenosis detection. RESULTS A total of 282 vascular segments were evaluated. Contrast-enhanced MR depicted three false-positive stenoses and all but two of 70 significant stenoses depicted with DSA. Sensitivity, specificity, and positive and negative predictive values of MR in detection of vessel segments with significant stenoses were 97% (95% CI: 90%, 99%), 99% (95% CI: 96%, 100%), 96% (95% CI: 88%, 99%), and 99% (95% CI: 97%, 100%), respectively. MR demonstrated significant stenosis in four of five nondiagnostic DSA segments, whereas DSA showed no significant stenosis in four nondiagnostic MR segments. Linear-weighted kappa statistic for interobserver agreement regarding stenosis detection was 0.92 (95% CI: 0.89, 0.95) for MR and 0.95 (95% CI: 0.92, 0.97) for DSA. CONCLUSION MR angiography depicts stenoses in dysfunctional hemodialysis accesses but has limited clinical value as result of current inability to perform MR-guided access interventions after stenosis detection. MR of dysfunctional access should be considered only if nondiagnostic vascular segment is present at DSA.
Collapse
Affiliation(s)
- Clemence L Froger
- Department of Radiology, Catharina Hospital, Michelangelolaan 2, 5623 EJ Eindhoven, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Miquel ME, Hegde S, Muthurangu V, Corcoran BJ, Keevil SF, Hill DLG, Razavi RS. Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients. Magn Reson Med 2004; 51:988-95. [PMID: 15122681 DOI: 10.1002/mrm.20041] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Passive catheter tracking involves direct interaction between the device and its surroundings, creating a local signal loss or enhancement of the image. Using only standard balloon catheters filled with CO(2) and imaged with a steady-state free precession sequence, it was possible to visualize and passively track catheters in a flow phantom and in the heart and great vessels of 20 patients without any additional image processing. The phantom work demonstrated that it was advantageous to sacrifice spatial resolution in order to increase temporal resolution. Frame rates greater than 10/sec were necessary for ease of catheter manipulation. Although only the tip of the catheter was visualized, this technique proved to be effective in patients undergoing cardiac catheterization.
Collapse
Affiliation(s)
- Marc E Miquel
- Division of Imaging Sciences, King's College London, UK
| | | | | | | | | | | | | |
Collapse
|
19
|
Bernstein MA, Shu Y, Elliott AM. RINGLET motion correction for 3D MRI acquired with the elliptical centric view order. Magn Reson Med 2004; 50:802-12. [PMID: 14523967 DOI: 10.1002/mrm.10584] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A new rigid-body motion correction algorithm is described that is compatible with 3D image sets acquired with the elliptical centric (EC) view order. With this view order, an annular ring of k-space data is acquired in the ky-kz plane during any short time interval. Images for tracking motion can be reconstructed in the yz-plane from any ring of the acquisition data. In these tracking images, a point source (such as an external marker) shows a characteristic bull's-eye pattern that permits motion monitoring and correction. The true position of the point object is located at the center of the bull's-eye pattern. Cross correlation can be performed to automatically track the positions of markers reconstructed from adjacent rings of k-space. To increase the marker signal, the markers are encased in inductively coupled RF coils. Rigid-body motion in the yz-plane is calculated directly with the Euclidean group for rotation and translation, and corrected by rotating and applying phase shifts to any corrupted rings of data. In the current work we present a theoretical analysis of this method, as well as results of volunteer and controlled phantom experiments that demonstrate its initial feasibility. Although the EC view order has mainly been used for MR angiography (MRA), it can also be used for most 3D acquisitions.
Collapse
|
20
|
Fink C, Bock M, Umathum R, Volz S, Zuehlsdorff S, Grobholz R, Kauczor HU, Hallscheidt P. Renal Embolization: Feasibility of Magnetic Resonance-Guidance Using Active Catheter Tracking and Intraarterial Magnetic Resonance Angiography. Invest Radiol 2004; 39:111-9. [PMID: 14734926 DOI: 10.1097/01.rli.0000110744.70512.df] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
RATIONALE AND OBJECTIVES Magnetic resonance (MR)-guidance of endovascular interventions offers various advantages, including the absence of ionizing radiation, excellent soft tissue contrast, and multiplanar and functional imaging capabilities. The objective of this study was to assess the feasibility of MR-guided renal embolization using active catheter tracking with automatic slice positioning and intraarterial contrast-enhanced MR angiography (MRA). MATERIALS AND METHODS MR-guided embolization of 16 kidneys was attempted in 15 pigs using real-time tracking of active 5-Fr. catheters. Embolization was monitored by selective intraarterial projection MRA. Intraarterial three-dimensional (3D) MRA was used for the assessment of embolization results. Additional pathologic correlation was available in 2 animals. The image quality of intraarterial 3D contrast-enhanced-MRA was rated by an independent radiologist who was not involved in the animal experiments. RESULTS Active catheter tracking with automatic slice positioning allowed reliable catheter guidance and catheterization of the renal artery in all animals. Embolization was successful in all kidneys (11 left, 5 right), as verified by intraarterial 3D contrast-enhanced MRA (ce-MRA) and/or pathology. The image quality of intraarterial 3D ce-MRA was rated excellent in 10 animals, moderate in 4 animals, and poor in 1 animal. CONCLUSION Renal embolization using active catheter tracking and intraarterial ce-MRA is feasible. Selective intraarterial ce-MRA allows the assessment of blood supply and organ perfusion before, during, and after therapeutic interventions, thereby complementing MR-guided endovascular interventions.
Collapse
Affiliation(s)
- Christian Fink
- Department of Radiology (E010), Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Tsekos NV, Atalar E, Li D, Omary RA, Serfaty JM, Woodard PK. Magnetic resonance imaging-guided coronary interventions. J Magn Reson Imaging 2004; 19:734-49. [PMID: 15170780 DOI: 10.1002/jmri.20071] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Magnetic resonance imaging (MRI) guidance for coronary interventions offers potential advantages over conventional x-ray angiography. Advantages include the use of nonionizing radiation, combined assessment of anatomy and function, and three-dimensional assessment of the coronary arteries leading to the myocardium. These advantages have prompted a series of recent studies in this field. Real-time coronary MR angiography, with low-dose catheter-directed intraarterial (IA) infusion of contrast media, has achieved in-plane spatial resolution as low as 0.8 x 0.8 mm2 and temporal resolution as short as 130 msec per image. Catheter-based IA injection of contrast agent has proven useful in the collection of multislice and three-dimensional images, not only for coronary intervention guidance, but also in the assessment of regional myocardial perfusion fed by the affected vessel. Actively visible guidewires and guiding catheters, based on the loopless antenna concept, have been effectively used to negotiate tortuous coronary vessels during catheterization, permitting placement of coronary angioplasty balloon catheters. Passive tracking approaches have been used to image contrast agent-filled coronary catheters and to place susceptibility-based endovascular stents. Although the field is in its infancy, these early results demonstrate the feasibility for performing MRI-guided coronary interventions. Although further methodological and technical developments are required before these methods become clinically applicable, we anticipate that MRI someday will be included in the armamentarium of techniques used to diagnose and treat coronary artery disease.
Collapse
Affiliation(s)
- Nikolaos V Tsekos
- Cardiovascular Imaging Laboratory, Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri 63110, USA.
| | | | | | | | | | | |
Collapse
|
22
|
Fayad ZA, Choudhury RP, Fuster V. Magnetic resonance imaging of coronary atherosclerosis. Curr Atheroscler Rep 2003; 5:411-7. [PMID: 12911852 DOI: 10.1007/s11883-003-0013-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Zahi A Fayad
- Imaging Science Laboratories, Mount Sinai School of Medicine, One Gustave L. Levy Place, Box 1234, New York, NY 10029, USA.
| | | | | |
Collapse
|
23
|
Zhang X, Zhu XH, Tian R, Zhang Y, Merkle H, Chen W. Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil. MAGMA (NEW YORK, N.Y.) 2003; 16:77-85. [PMID: 12845538 DOI: 10.1007/s10334-003-0013-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2003] [Accepted: 05/05/2003] [Indexed: 11/25/2022]
Abstract
A method of determining arterial input function (AIF) by continuously detecting the (17)O MR signal changes of (17)O-labeled water tracer in the rat carotid artery using a region-defined (REDE) implanted vascular RF coil at 9.4 Tesla is reported. This coil has a compact physical size of 1 mm inner diameter, 3 mm outer diameter and 11 mm in length. It can be readily implanted into the rat neck and wrapped around the rat carotid artery for achieving adequate MR detection sensitivity for determining AIF with minimal surgical trauma. Water phantom and in vivo MR experiments were conducted for validating the coil's performance. A signal-to-noise ratio of approximately 20:1 was achieved for the (17)O signal acquired from naturally abundant H(2)(17)O in a small amount of blood (approximately 7 microl) inside the rat carotid artery with an acquisition time of 11 s. The REDE RF coil design electromagnetically isolates the rat carotid artery from surrounding tissues and ensures that the MR signal detected by the RF coil is only attributable to the artery blood. It also minimizes the electromagnetic coupling between the implanted RF coil and a head surface coil tuned at the same operating frequency (two-coil configuration). This configuration allowed simultaneous measurements of dynamic changes of (17)O MR signal of the H(2)(17)O tracer in both rat carotid artery and brain. Compared to most contemporary MR approaches, the REDE implanted RF provides a simple, accurate, and promising solution for determination of AIF in small experimental animals.
Collapse
Affiliation(s)
- Xiaoliang Zhang
- Center for Magnetic Resonance Research, University of Minnesota School of Medicine, 2021 6th Street S.E., Department of Radiology, Minneapolis, Minnesota, USA
| | | | | | | | | | | |
Collapse
|
24
|
Kuehne T, Fahrig R, Butts K. Pair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations. J Magn Reson Imaging 2003; 17:620-4. [PMID: 12720274 DOI: 10.1002/jmri.10307] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To test wireless resonance circuits (RC) to be used as fiducial marker of endovascular catheters during MR-guided interventions. Current markers loose their signal enhancement for certain catheter orientations. The purpose of this study was to test a marker setup which overcomes this orientation problem. MATERIALS AND METHODS The markers were constructed from a pair of two RCs. The RCs were individually tuned and the coil axes were oriented perpendicular to each other in order to decouple the two RCs. The markers were mounted on the tip of endovascular catheters and tested in vitro and in one porcine in vivo experiment. RESULTS An intense MR signal at similar signal levels was noted at all catheter orientations. In the in vivo experiment the markers allowed for fast and reliable MR guidance of the catheters. CONCLUSION A pair of two individually tuned and decoupled RCs is well suited for MR guidance of endovascular catheters.
Collapse
Affiliation(s)
- Titus Kuehne
- Department of Radiology, Stanford University, Palto Alto, California 94304, USA
| | | | | |
Collapse
|
25
|
|
26
|
Kuehne T, Saeed M, Higgins CB, Gleason K, Krombach GA, Weber OM, Martin AJ, Turner D, Teitel D, Moore P. Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology 2003; 226:475-81. [PMID: 12563142 DOI: 10.1148/radiol.2262011639] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To assess the feasibility of using magnetic resonance (MR) imaging to guide stent deployment in the pulmonary valve and artery and evaluate, after stent deployment, the position and morphology of and blood flow through the stent. MATERIALS AND METHODS Angiography and 1.5-T MR imaging were performed in a dual-imaging suite. Nitinol stents were placed in the pulmonary valve and main pulmonary artery in five pigs by using MR imaging guidance. For interactive MR imaging monitoring of catheter manipulation and stent delivery, balanced fast field-echo and T1-weighted turbo field-echo sequences were used. Visualization of the delivery system was based on T2* (with air as the contrast material) or T1 (with gadodiamide as the contrast material). After stent deployment, the position and morphology of and flow through the stent were verified with multiphase multisection balanced fast field-echo and velocity-encoded cine MR imaging. Findings at angiography and postmortem examination also helped verify stent placement. The paired Student t test was used for data analysis. RESULTS The stent was successfully deployed in all animals. The stent was placed distal to the pulmonary valve in four animals and across the pulmonary valve in one animal. The position and morphology of the stent were clearly depicted on balanced fast field-echo images. In the animal with the stent placed across the pulmonary valve, the pulmonary regurgitant fraction was 37%; this was not seen in the animals with stents placed distal to the pulmonary valve. No complication (eg, stent migration, intramural injury, or vascular perforation) was noted during the intervention. Findings at angiography and postmortem examination confirmed the position of the stents. CONCLUSION MR imaging has the potential to guide stent placement in the pulmonary valve or artery and to evaluate flow volume within the stent lumen after the intervention.
Collapse
Affiliation(s)
- Titus Kuehne
- Department of Radiology, University of California San Francisco, 505 Parnassus Ave, L308, San Francisco, CA 94143-0628, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Moelker A, Maas RAJJ, Lethimonnier F, Pattynama PMT. Interventional MR imaging at 1.5 T: quantification of sound exposure. Radiology 2002; 224:889-95. [PMID: 12202729 DOI: 10.1148/radiol.2243010978] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Sound pressure levels (SPLs) during interventional magnetic resonance (MR) imaging may create an occupational hazard for the interventional radiologist (ie, the potential risk of hearing impairment). Therefore, A-weighted and linear continuous-equivalent SPLs were measured at the entrance of a 1.5-T MR imager during cardiovascular and real-time pulse sequences. The SPLs ranged from 81.5 to 99.3 dB (A-weighted scale), and frequencies were from 1 to 3 kHz. SPLs for the interventional radiologist exceeded a safe SPL of 80 dB (A-weighted scale) for all sequences; therefore, hearing protection is recommended.
Collapse
Affiliation(s)
- Adriaan Moelker
- Department of Radiology, Erasmus University Medical Center Rotterdam, 50 Dr Molewaterplein, P.O. Box 1738, the Netherlands.
| | | | | | | |
Collapse
|
28
|
Choudhury RP, Fuster V, Badimon JJ, Fisher EA, Fayad ZA. MRI and characterization of atherosclerotic plaque: emerging applications and molecular imaging. Arterioscler Thromb Vasc Biol 2002; 22:1065-74. [PMID: 12117718 DOI: 10.1161/01.atv.0000019735.54479.2f] [Citation(s) in RCA: 105] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Noninvasive high-resolution magnetic resonance has the potential to image atherosclerotic plaque and to determine its composition and microanatomy. This review summarizes the rationale for plaque imaging and describes the characteristics of plaque by use of existing MRI techniques. The use of MRI in human disease and in animal models, particularly in rabbits and mice, is presented. Present and future applications of MRI, including real-time vascular intervention, new contrast agents, and molecular imaging, are also discussed.
Collapse
Affiliation(s)
- Robin P Choudhury
- Department of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford, UK
| | | | | | | | | |
Collapse
|
29
|
Kuehne T, Saeed M, Moore P, Gleason K, Reddy G, Teitel D, Higgins CB. Influence of blood-pool contrast media on MR imaging and flow measurements in the presence of pulmonary arterial stents in swine. Radiology 2002; 223:439-45. [PMID: 11997550 DOI: 10.1148/radiol.2232010975] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To compare the effects of various stents on magnetic resonance (MR) imaging flow volume measurements and to determine the value of a blood-pool MR imaging contrast medium in assessment of vascular stents. MATERIALS AND METHODS In 11 pigs, six nitinol stents (Memotherm), four platinum stents (NuMed), and one elgiloy stent (Wallstent) were placed in the main pulmonary artery under x-ray fluoroscopic guidance. MR imaging was performed 3 months after stent placement before and after injection of NC100150 contrast medium. Blood flow volumes were assessed with velocity-encoded cine MR imaging through and next to the stent. The signal-to-noise ratio and width of susceptibility artifacts of the stents also were determined. Measurements were analyzed with the paired Student t test and Bland-Altman test, where appropriate. RESULTS Blood flow volumes measured through the nitinol and platinum stents disclosed no significant difference between velocity-encoded cine MR imaging measurements through and next to the stent. On cine MR images, small susceptibility artifacts were observed around the nitinol and platinum stents. Signal-to-noise ratio in the stent lumen was reduced in nitinol and platinum stents when compared with that next to the stent. The elgiloy stent produced severe susceptibility artifacts, making measurement of flow volumes impossible. NC100150 injection caused no significant effect on flow volume measurements. It improved the signal-to-noise ratio of the pulmonary arterial lumen outside and, to a lesser extent, inside the stent. CONCLUSION Assessment of morphology and flow volumes through nitinol and platinum stents is feasible with MR imaging. Blood-pool contrast media provide persistent signal enhancement in the pulmonary artery and, to a lesser extent, in the lumina of nitinol and platinum stents.
Collapse
Affiliation(s)
- Titus Kuehne
- Department of Radiology, Division of Pediatric Cardiology, University of California San Francisco, 505 Parnassus Ave, L308, San Francisco, CA 94143-0628, USA
| | | | | | | | | | | | | |
Collapse
|
30
|
Susil RC, Yeung CJ, Halperin HR, Lardo AC, Atalar E. Multifunctional interventional devices for MRI: a combined electrophysiology/MRI catheter. Magn Reson Med 2002; 47:594-600. [PMID: 11870847 DOI: 10.1002/mrm.10088] [Citation(s) in RCA: 62] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The design and application of a two-wire electrophysiology (EP) catheter that simultaneously records the intracardiac electrogram and receives the MR signal for active catheter tracking is described. The catheter acts as a long loop receiver, allowing for visualization of the entire catheter length while simultaneously behaving as a traditional two-wire EP catheter, allowing for intracardiac electrogram recording and ablation. The application of the device is demonstrated by simultaneously tracking the catheter and recording the intracardiac electrogram in canine models using 7 and 10 frame/sec real-time imaging sequences. Using solely MR imaging, the entire catheter was visualized and guided from the jugular vein into the cardiac chambers, where the intracardiac electrogram was recorded. By combining several functions in a single, simple structure, the excellent tissue contrast and functional imaging capabilities of MR can be used to improve the efficacy of EP interventions. This catheter will facilitate MR-guided interventions and demonstrates the design of multifunctional interventional devices for use in MRI.
Collapse
Affiliation(s)
- Robert C Susil
- Departments of Biomedical Engineering, Radiology, and Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | | | | | | | | |
Collapse
|
31
|
Duerk JL, Wong EY, Lewin JS. A brief review of hardware for catheter tracking in magnetic resonance imaging. MAGMA (NEW YORK, N.Y.) 2002; 13:199-208. [PMID: 11755097 DOI: 10.1007/bf02678597] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Magnetic resonance imaging (MRI) has traditionally been used exclusively in a role for patient diagnosis. However, it is unlikely that this role is sufficient for its continued prominence in medical imaging. Instead, the more ambitious role in diagnosis and also therapy/intervention will occur as demand for minimally invasive procedures increases. Fortunately, with recent improvement in technical specifications and creative pulse sequence design, MRI systems can now provide high quality near-real-time images that facilitate a variety of image-guided procedures, many based around delivery via catheters. While X-ray opacity is not available as a means for detecting the progression of the catheter in MRI systems today, a variety of novel hardware devices have been designed and used for MRI catheter tracking. This report provides a brief review of some fundamental methods for catheter tracking in MRI.
Collapse
Affiliation(s)
- Jeffrey L Duerk
- Department of Radiology, Case Western Reserve University and University Hospitals of Cleveland, 11100 Euclid Avenue, Cleveland, OH 44106, USA.
| | | | | |
Collapse
|
32
|
Guttman MA, Lederman RJ, Sorger JM, McVeigh ER. Real-time volume rendered MRI for interventional guidance. J Cardiovasc Magn Reson 2002; 4:431-42. [PMID: 12549231 PMCID: PMC2570028 DOI: 10.1081/jcmr-120016382] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
Volume renderings from magnetic resonance imaging data can be created and displayed in real-time with user interactivity. This can provide continuous 3D feedback to assist in guiding an interventional procedure. A system is presented which can produce real-time volume renderings from 2D multi-slice or 3D MR pulse sequences. Imaging frame rates up to 30 per second have been demonstrated with a latency of approximately one-third of a second, depending on the image matrix size. Several interactive capabilities have been implemented to enhance visualization such as cut planes, individual channel scaling and color highlighting, view sharing, saturation preparation, complex subtraction, gating control, and choice of alpha blending or MIP rendering. The system is described and some interventional application examples are shown. To view movies of some of the examples, enter the following address into a web browser: http://nhlbi.nih.gov/labs/papers/lce/guttman/rtvolmri/index/htm.
Collapse
Affiliation(s)
- Michael A Guttman
- Laboratory of Cardiac Energetics, National Institutes of Health, National Heart, Lung and Blood Institute, 10 Center Dr., Building 10, Room B1D416, Bethesda, MD 20892-1061, USA.
| | | | | | | |
Collapse
|