1
|
Pizzini F, Beltramello A, Piovan E, Alessandrini F. Diffusion-Weighted and Diffusion Tensor Magnetic Resonance Brain Imaging: Principles and Applications. ACTA ACUST UNITED AC 2016. [DOI: 10.1177/197140090301600202] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Diffusion Weighted Imaging (DWI) is one of the most recent products of Magnetic Resonance (MR) technology evolution. DWI has been proposed as a noninvasive tool for evaluating structural and physiologic states in biologic tissues as hyperacute ischemic changes within brain tissue. Recently, its more complex and detailed evolution, Diffusion Tensor Imaging (DTI), has been introduced and its clinical applications are the evaluation of anatomical structures and pathologic processes in white matter. White matter quantitative maps that indicate the integrity of brain tissue, color map, and tractography that identifies macroscopic three-dimensional architecture of fiber tracts (e.g., projections and association pathways) can be obtained with DTI. Diffusion weighted imaging visualization techniques (ADC and Trace) are applied for the study of stroke, in the differential diagnosis of expansive lesions (e.g. epidermoid vs. arachnoid cyst) and in detecting traumatic and other lesions associated with restricted diffusion (e.g. MS plaques). On the other hand, DTI provides the identification of abnormalities in the otherwise normal appearing white matter with the understanding of the organization of the fibers, both in tumors and in other cortical or white matter diseases (including stroke, dementias, demyelinating-dismyelinating diseases, epilepsy, schizophrenia). Furthermore, in combination with functional MR, DTI might contribute to the comprehension of brain development, aging and connectivity, thus having a significant impact on brain functional studies.
Collapse
Affiliation(s)
- F. Pizzini
- Service of Neuroradiology, Verona University Hospital, Verona, Italy
| | - A. Beltramello
- Service of Neuroradiology, Verona University Hospital, Verona, Italy
| | - E. Piovan
- Service of Neuroradiology, Verona University Hospital, Verona, Italy
| | - F. Alessandrini
- Service of Neuroradiology, Verona University Hospital, Verona, Italy
| |
Collapse
|
2
|
Ginat DT, Swearingen B, Curry W, Cahill D, Madsen J, Schaefer PW. 3 Tesla intraoperative MRI for brain tumor surgery. J Magn Reson Imaging 2013; 39:1357-65. [DOI: 10.1002/jmri.24380] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Affiliation(s)
- Daniel Thomas Ginat
- Department of Radiology, Massachusetts General Hospital; Harvard Medical School; Boston Massachusetts USA
| | - Brooke Swearingen
- Department of Neurosurgery, Massachusetts General Hospital; Harvard Medical School; Boston Massachusetts USA
| | - William Curry
- Department of Neurosurgery, Massachusetts General Hospital; Harvard Medical School; Boston Massachusetts USA
| | - Daniel Cahill
- Department of Neurosurgery, Massachusetts General Hospital; Harvard Medical School; Boston Massachusetts USA
| | - Joseph Madsen
- Department of Neurosurgery, Boston Children's Hospital; Harvard Medical School; Boston Massachusetts USA
| | - Pamela W. Schaefer
- Department of Neurosurgery, Boston Children's Hospital; Harvard Medical School; Boston Massachusetts USA
| |
Collapse
|
3
|
Daga P, Winston G, Modat M, White M, Mancini L, Cardoso MJ, Symms M, Stretton J, McEvoy AW, Thornton J, Micallef C, Yousry T, Hawkes DJ, Duncan JS, Ourselin S. Accurate localization of optic radiation during neurosurgery in an interventional MRI suite. IEEE TRANSACTIONS ON MEDICAL IMAGING 2012; 31:882-891. [PMID: 22194240 DOI: 10.1109/tmi.2011.2179668] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Accurate localization of the optic radiation is key to improving the surgical outcome for patients undergoing anterior temporal lobe resection for the treatment of refractory focal epilepsy. Current commercial interventional magnetic resonance imaging (MRI) scanners are capable of performing anatomical and diffusion weighted imaging and are used for guidance during various neurosurgical procedures. We present an interventional imaging workflow that can accurately localize the optic radiation during surgery. The workflow is driven by a near real-time multichannel nonrigid image registration algorithm that uses both anatomical and fractional anisotropy pre- and intra-operative images. The proposed workflow is implemented on graphical processing units and we perform a warping of the pre-operatively parcellated optic radiation to the intra-operative space in under 3 min making the proposed algorithm suitable for use under the stringent time constraints of neurosurgical procedures. The method was validated using both a numerical phantom and clinical data using pre- and post-operative images from patients who had undergone surgery for treatment of refractory focal epilepsy and shows strong correlation between the observed post-operative visual field deficit and the predicted damage to the optic radiation. We also validate the algorithm using interventional MRI datasets from a small cohort of patients. This work could be of significant utility in image guided interventions and facilitate effective surgical treatments.
Collapse
Affiliation(s)
- Pankaj Daga
- Department of Computer Science, University College London, UK.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Colen RR, Kekhia H, Jolesz FA. Multimodality intraoperative MRI for brain tumor surgery. Expert Rev Neurother 2011; 10:1545-58. [PMID: 20945538 DOI: 10.1586/ern.10.145] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Intraoperative MRI has already fundamentally changed the way current brain tumor surgery is performed. The ability to integrate high-field MRI into the operating room has allowed intraoperative MRI to emerge as an important adjunct to CNS tumor treatment. Furthermore, the ability of MRI to successfully couple with molecular imaging (PET and/or optical imaging), neuroendoscopy and therapeutic devices, such as focused ultrasound, will allow it to emerge as an important image-guidance modality for improving brain tumor therapy and outcomes.
Collapse
Affiliation(s)
- Rivka R Colen
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA
| | | | | |
Collapse
|
5
|
Hygino da Cruz LC, Vieira IG, Domingues RC. Diffusion MR Imaging: An Important Tool in the Assessment of Brain Tumors. Neuroimaging Clin N Am 2011; 21:27-49, vii. [DOI: 10.1016/j.nic.2011.01.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
6
|
Hori M, Ishigame K, Aoki S, Kumagai H, Araki T. Diffusion Tensor Imaging and 3D Tractography of the Cervical Spinal Cord Using the ECG-Gated Line-scan Technique. A Feasibility Study. Neuroradiol J 2007; 20:574-9. [PMID: 24299949 DOI: 10.1177/197140090702000517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2007] [Accepted: 08/15/2007] [Indexed: 11/15/2022] Open
Abstract
Diffusion tensor (DT) magnetic resonance (MR) imaging in addition to conventional MR images provide valuable information on the brain. This study compared line scan DT imaging with and without the ECG-gating technique to estimate clinical usefulness of the line scan diffusion tensor image (LSDTI) with ECG-gating in evaluating spinal cord diseases in vivo. First, five healthy volunteers participated in the comparison study. LSDWI was performed in three to five sagittal sections with a pulsed-field-gradient diffusion preparation pulse employing two different b-values (0 and 700 s/mm(2)) along six directions. Apparent diffusion coefficient (ADC) maps and fractional anisotropy (FA) were calculated and three-dimensional tract reconstruction and color schemes of the spinal cord were obtained. Image quality and the acquisition time of each LSDTI were compared. Second, LSDTI with ECG-gating was performed in eighteen patients with cervical spinal cord disorders and evaluated by two neuroradiologists. Images with the ECG-gated technique were all superior to those without ECG-gating. Mean extended time for LSDTI with ECG-gating was approximately two minutes. In clinical use, the ADC and FA of spinal cord in patients with cervical spondylotic myelopathy statically changed. Moreover, demonstration of fibers was correlated with clinical symptoms. ECG-gating technique is preferable to LSDTI. The ADC and FA measurements and 3D fiber tracking of LSDTI with ECG-gating are promising methods to estimate cervical spinal cord pathology in clinical use.
Collapse
Affiliation(s)
- M Hori
- Radiology Department, Toho University; Ota, Tokyo, Japan - -
| | | | | | | | | |
Collapse
|
7
|
Abstract
Diffusion tensor imaging (DTI) is a promising method for characterizing microstructural changes or differences with neuropathology and treatment. The diffusion tensor may be used to characterize the magnitude, the degree of anisotropy, and the orientation of directional diffusion. This review addresses the biological mechanisms, acquisition, and analysis of DTI measurements. The relationships between DTI measures and white matter pathologic features (e.g., ischemia, myelination, axonal damage, inflammation, and edema) are summarized. Applications of DTI to tissue characterization in neurotherapeutic applications are reviewed. The interpretations of common DTI measures (mean diffusivity, MD; fractional anisotropy, FA; radial diffusivity, D(r); and axial diffusivity, D(a)) are discussed. In particular, FA is highly sensitive to microstructural changes, but not very specific to the type of changes (e.g., radial or axial). To maximize the specificity and better characterize the tissue microstructure, future studies should use multiple diffusion tensor measures (e.g., MD and FA, or D(a) and D(r)).
Collapse
Affiliation(s)
- Andrew L Alexander
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA.
| | | | | | | |
Collapse
|
8
|
Rasmussen IA, Lindseth F, Rygh OM, Berntsen EM, Selbekk T, Xu J, Nagelhus Hernes TA, Harg E, Håberg A, Unsgaard G. Functional neuronavigation combined with intra-operative 3D ultrasound: initial experiences during surgical resections close to eloquent brain areas and future directions in automatic brain shift compensation of preoperative data. Acta Neurochir (Wien) 2007; 149:365-78. [PMID: 17308976 DOI: 10.1007/s00701-006-1110-0] [Citation(s) in RCA: 118] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2006] [Accepted: 12/13/2006] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The aims of this study were: 1) To develop protocols for, integration and assessment of the usefulness of high quality fMRI (functional magnetic resonance imaging) and DTI (diffusion tensor imaging) data in an ultrasound-based neuronavigation system. 2) To develop and demonstrate a co-registration method for automatic brain-shift correction of pre-operative MR data using intra-operative 3D ultrasound. METHODS Twelve patients undergoing brain surgery were scanned to obtain structural and fMRI data before the operation. In six of these patients, DTI data was also obtained. The preoperative data was imported into a commercial ultrasound-based navigation system and used for surgical planning and guidance. Intra-operative ultrasound volumes were acquired when needed during surgery and the multimodal data was used for guidance and resection control. The use of the available image information during planning and surgery was recorded. An automatic voxel-based registration method between preoperative MRA and intra-operative 3D ultrasound angiography (Power Doppler) was developed and tested postoperatively. RESULTS The study showed that it is possible to implement robust, high-quality protocols for fMRI and DTI and that the acquired data could be seamlessly integrated in an ultrasound-based neuronavigation system. Navigation based on fMRI data was found to be important for pre-operative planning in all twelve procedures. In five out of eleven cases the data was also found useful during the resection. DTI data was found to be useful for planning in all five cases where these data were imported into the navigation system. In two out of four cases DTI data was also considered important during the resection (in one case DTI data were acquired but not imported and in another case fMRI and DTI data could only be used for planning). Information regarding the location of important functional areas (fMRI) was more beneficial during the planning phase while DTI data was more helpful during the resection. Furthermore, the surgeon found it more user-friendly and efficient to interpret fMRI and DTI information when shown in a navigation system as compared to the traditional display on a light board or monitor. Updating MRI data for brain-shift using automatic co-registration of preoperative MRI with intra-operative ultrasound was feasible. CONCLUSION In the present study we have demonstrated how both fMRI and DTI data can be acquired and integrated into a neuronavigation system for improved surgical planning and guidance. The surgeons reported that the integration of fMRI and DTI data in the navigation system represented valuable additional information presented in a user-friendly way and functional neuronavigation is now in routine use at our hospital. Furthermore, the present study showed that automatic ultrasound-based updates of important pre-operative MRI data are feasible and hence can be used to compensate for brain shift.
Collapse
Affiliation(s)
- I-A Rasmussen
- Norwegian University of Science and Technology, Trondheim, Norway
| | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Archip N, Clatz O, Whalen S, Kacher D, Fedorov A, Kot A, Chrisochoides N, Jolesz F, Golby A, Black PM, Warfield SK. Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery. Neuroimage 2006; 35:609-24. [PMID: 17289403 PMCID: PMC3358788 DOI: 10.1016/j.neuroimage.2006.11.060] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2006] [Revised: 11/15/2006] [Accepted: 11/16/2006] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE The usefulness of neurosurgical navigation with current visualizations is seriously compromised by brain shift, which inevitably occurs during the course of the operation, significantly degrading the precise alignment between the pre-operative MR data and the intra-operative shape of the brain. Our objectives were (i) to evaluate the feasibility of non-rigid registration that compensates for the brain deformations within the time constraints imposed by neurosurgery, and (ii) to create augmented reality visualizations of critical structural and functional brain regions during neurosurgery using pre-operatively acquired fMRI and DT-MRI. MATERIALS AND METHODS Eleven consecutive patients with supratentorial gliomas were included in our study. All underwent surgery at our intra-operative MR imaging-guided therapy facility and have tumors in eloquent brain areas (e.g. precentral gyrus and cortico-spinal tract). Functional MRI and DT-MRI, together with MPRAGE and T2w structural MRI were acquired at 3 T prior to surgery. SPGR and T2w images were acquired with a 0.5 T magnet during each procedure. Quantitative assessment of the alignment accuracy was carried out and compared with current state-of-the-art systems based only on rigid registration. RESULTS Alignment between pre-operative and intra-operative datasets was successfully carried out during surgery for all patients. Overall, the mean residual displacement remaining after non-rigid registration was 1.82 mm. There is a statistically significant improvement in alignment accuracy utilizing our non-rigid registration in comparison to the currently used technology (p<0.001). CONCLUSIONS We were able to achieve intra-operative rigid and non-rigid registration of (1) pre-operative structural MRI with intra-operative T1w MRI; (2) pre-operative fMRI with intra-operative T1w MRI, and (3) pre-operative DT-MRI with intra-operative T1w MRI. The registration algorithms as implemented were sufficiently robust and rapid to meet the hard real-time constraints of intra-operative surgical decision making. The validation experiments demonstrate that we can accurately compensate for the deformation of the brain and thus can construct an augmented reality visualization to aid the surgeon.
Collapse
Affiliation(s)
- Neculai Archip
- Department of Radiology, Harvard Medical School, Brigham and Women's Hospital, 75 Francis St., Boston, MA 02115, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Antonsson J, Eriksson O, Lundberg P, Wårdell K. Optical Measurements during Experimental Stereotactic Radiofrequency Lesioning. Stereotact Funct Neurosurg 2006; 84:118-24. [PMID: 16840822 DOI: 10.1159/000094463] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The aim of this study was to evaluate in vivo a laser Doppler measurement system in porcine brain tissue during thermal lesioning. A 2-mm monopolar radiofrequency lesioning electrode was equipped with optical fibers in order to monitor the lesioning procedure. Laser Doppler and backscattered light intensity signals were measured along the electrode trajectory and during bilateral lesioning in the central gray (70, 80 and 90 degrees C, n = 14). The time course of the coagulation process could be followed by optical recordings. Two separate groups of tissue were identified from the intensity signals. The changes in the perfusion levels in both groups displayed significant changes (p < 0.05, n = 48) at all temperature settings, while backscattered light intensity was significant for only one group at the different temperatures (p < 0.05, n = 39). These results indicate that optical measurements correlate with lesion development in vivo. The study also indicates that it is possible to follow the lesioning process intra-operatively.
Collapse
Affiliation(s)
- Johan Antonsson
- Department of Biomedical Engineering, Linkoping University, Linkoping, Sweden.
| | | | | | | |
Collapse
|
11
|
Nimsky C, Ganslandt O, Hastreiter P, Wang R, Benner T, Sorensen AG, Fahlbusch R. Preoperative and intraoperative diffusion tensor imaging-based fiber tracking in glioma surgery. Neurosurgery 2006; 56:130-7; discussion 138. [PMID: 15617595 DOI: 10.1227/01.neu.0000144842.18771.30] [Citation(s) in RCA: 250] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2004] [Accepted: 08/27/2004] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE To investigate the intraoperative displacement of major white matter tracts during glioma resection by comparing preoperative and intraoperative diffusion tensor imaging-based fiber tracking. METHODS In 37 patients undergoing glioma surgery, preoperative and intraoperative diffusion tensor imaging was performed with a 1.5-T magnetic resonance scanner applying an echo-planar imaging sequence with six diffusion directions. For three-dimensional tractography, we implemented a knowledge-based multiple-region-of-interest approach applying user-defined seed regions in the color-coded maps of fractional anisotropy. Tracking was initiated in both the retrograde and orthograde directions according to the direction of the principal eigenvector in each voxel of the region of interest. The tractography results were also assigned color, applying the convention used in color-coded fractional anisotropy maps. RESULTS Preoperative and intraoperative fiber tracking was technically feasible in all patients. Fiber tract visualization gave a quick and intuitive overview of the displaced course of white matter tracts in three-dimensional space. Comparison of preoperative and intraoperative tractography depicted a marked shifting of major white matter tracts during glioma removal. Maximum white matter tract shifting ranged from -8 to +15 mm (+2.7 +/- 6.0 mm; mean +/- standard deviation); in 29.7%, an inward and in 62.2%, an outward shifting was detected. CONCLUSION Comparing preoperative and intraoperative fiber tracking visualizes a marked shifting and deformation of major white matter tracts because of tumor removal. This shifting emphasizes the need for an intraoperative update of navigation systems during resection of deep-seated tumor portions near eloquent brain areas. Fiber tracking is a method not only for preoperative neurosurgical visualization but also for further intraoperative planning.
Collapse
Affiliation(s)
- Christopher Nimsky
- Department of Neurosurgery, University Erlangen-Nürnberg, Erlangen, Germany.
| | | | | | | | | | | | | |
Collapse
|
12
|
Hori M, Okubo T, Aoki S, Kumagai H, Araki T. Line scan diffusion tensor MRI at low magnetic field strength: feasibility study of cervical spondylotic myelopathy in an early clinical stage. J Magn Reson Imaging 2006; 23:183-8. [PMID: 16374879 DOI: 10.1002/jmri.20488] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To implement line scan diffusion tensor MR imaging (LSDTI) on a 0.2 Tesla MR imager, and investigate the findings in the spinal cord of patients with cervical spondylotic myelopathy in an early clinical stage. MATERIALS AND METHODS Fourteen patients with clinical symptoms of cervical myelopathy underwent LSDTI. The signal-to-noise ratio (SNR) in the spinal cord and cerebrospinal fluid (CSF) was evaluated. The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) were measured. We classified the ROIs into two groups: 1) unaffected (no clinical symptoms and no abnormality on conventional images) and 2) affected (some clinical symptoms but no abnormal signal on conventional images). Three-dimensional (3D) fiber-tracking was also studied. RESULTS The isotropic ADC values (10(-3)mm2/sec) were 1.28 +/- 0.11 in group 1 and 1.59 +/- 0.23 in group 2. The FAs were 0.55 +/- 0.07 in group 1, and 0.47 +/- 0.11 in group 2. The ADC value in group 2 increased (P < .001, Mann-Whitney U-test) and the FA in group 2 decreased (P = 0.24) on average, compared to those in group 1. 3D fiber-tracking was successful in 64% (9/14) of the cases. CONCLUSION LSDT images at low field strength may be a sensitive method for elucidating the structural characteristics of spinal cord pathology in vivo. However, clinical correlation and a long-term follow-up study will be needed.
Collapse
Affiliation(s)
- Masaaki Hori
- Department of Radiology, University of Yamanashi, Yamanashi, Japan.
| | | | | | | | | |
Collapse
|
13
|
Cruz LCH, Sorensen AG. Diffusion Tensor Magnetic Resonance Imaging of Brain Tumors. Magn Reson Imaging Clin N Am 2006; 14:183-202. [PMID: 16873010 DOI: 10.1016/j.mric.2006.06.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
DTI seems to offer the possibility of adding important information to presurgical planning. Although experience is limited, DTI seems to provide useful local information about the structures near the tumor, and this seems to be useful in planning. In the future, DTI may provide an improved way to monitor intraoperative surgical procedures as well as their complications. Furthermore, evaluation of the response to treatment with chemotherapy and radiation therapy might also be possible. Although DTI has some limitations, its active investigation and further study are clearly warranted.
Collapse
Affiliation(s)
- L Celso Hygino Cruz
- Clínica de Diagnóstico por Imagem, Multi-Imagem Ressonância Magnética, Av. das Ameréricas 4666, Centro Médico Barrashopping, Rio de Janeiro, Brazil
| | | |
Collapse
|
14
|
Terada H, Gomi T, Harada H, Chiba T, Nakamura T, Iwabuchi S, Nemoto H, Kawasaki S, Watanabe S, Nagamoto M, Kawawa Y, Kohda E. Development of diffusion-weighted image using a 0.3T open MRI. J Neuroradiol 2006; 33:57-61. [PMID: 16528207 DOI: 10.1016/s0150-9861(06)77229-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The purpose of this study was to develop a new technique for diffusion-weighted MRI (DWI) with a low-field scanner. DWI is becoming important for assessment of acute stroke. Until recently DWI required expensive technology. We developed multishot-DWI sequence for 0.3T open type MR imager. We prospectively studied forty patients on this 0.3T MRI and compared this DWI to single-shot-DWI by 1.5T-MRI. Group A: Twenty-four patients with acute cerebral infarctions detected by 1.5T-DWI were re-examined using 0.3T-DWI within 24 hours. Sixteen patients with acute cerebral infarctions detected by 0.3T-DWI were re-examined using 1.5T-DWI within 24 hours. In 22 (92%) of 24 cases, 0.3T-DWI showed high signal. In the other two patients, motion artifact distorted 0.3T-DWI. Group B: In all 16 patients, all infarctions detected by 0.3T-DWI showed high signal on 1.5T-DWI. These preliminary data show that, as long as the patient is able to keep still, multishot-DWI can be acquired successfully on a 0.3T open type MRI system.
Collapse
Affiliation(s)
- H Terada
- Department of Radiology, Toho University Ohashi Hospital, Ohashi 2-17-6, Tokyo-Meguro 153-8515, Japan.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Nimsky C, Ganslandt O, Merhof D, Sorensen AG, Fahlbusch R. Intraoperative visualization of the pyramidal tract by diffusion-tensor-imaging-based fiber tracking. Neuroimage 2005; 30:1219-29. [PMID: 16364659 DOI: 10.1016/j.neuroimage.2005.11.001] [Citation(s) in RCA: 201] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2005] [Revised: 10/29/2005] [Accepted: 11/03/2005] [Indexed: 11/22/2022] Open
Abstract
Functional neuronavigation allows intraoperative visualization of cortical eloquent brain areas. Major white matter tracts, such as the pyramidal tract, can be delineated by diffusion-tensor-imaging based fiber tracking. These tractography data were integrated into 3-D datasets applied for neuronavigation by rigid registration of the diffusion images with standard anatomical image data so that their course could be superimposed onto the surgical field during resection of gliomas. Intraoperative high-field magnetic resonance imaging was used to compensate for the effects of brain shift, which amounted up to 8 mm. Despite image distortion of echo planar images, which was identified by non-linear registration techniques, navigation was reliable. In none of the 19 patients new postoperative neurological deficits were encountered. Intraoperative visualization of major white matter tracts allows save resection of gliomas near eloquent brain areas. A possible shifting of the pyramidal tract has to be taken into account after major tumor parts are resected.
Collapse
Affiliation(s)
- Christopher Nimsky
- Department of Neurosurgery, University Erlangen-Nürnberg, Schwabachanlage 6, 91054 Erlangen, Germany.
| | | | | | | | | |
Collapse
|
16
|
Hori M, Aoki S, Okubo T, Ishigame K, Kumagai H, Araki T. Line-scan diffusion tensor MR imaging at 0.2 T: Feasibility study. J Magn Reson Imaging 2005; 22:794-8. [PMID: 16270295 DOI: 10.1002/jmri.20440] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To investigate and measure apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values using data obtained with line-scan diffusion-weighted imaging (DWI) of human brains on a 0.2 Tesla MR imager. MATERIALS AND METHODS Diffusion-tensor imaging (DTI) was performed on eight healthy volunteers. The signal-to-noise ratios (SNRs) of white matter and cerebrospinal fluid were measured. ADC and FA were also measured from the data obtained from all subjects. Three-dimensional corticospinal fiber tracts were reconstructed from the DT images and a qualitative evaluation was done. RESULTS The total scan time was 52 minutes 30 seconds for 18 slices with full-tensor images covering the whole brain. The ADCs and FAs show the appropriate values, in comparison with values obtained at high field strength in previous studies. Corticospinal fibers were demonstrated more clearly on images obtained at 0.2 T than at 1.5T. CONCLUSION DTI at low field strength may be feasible for clinical use to estimate the white matter of brain with limited coverage, which often may be sufficient.
Collapse
Affiliation(s)
- Masaaki Hori
- Department of Radiology, University of Yamanashi, Yamanashi, Japan.
| | | | | | | | | | | |
Collapse
|
17
|
Abstract
This review discusses imaging techniques for the diagnosis, treatment, and monitoring of brain metastases. It assesses the various modalities on the basis of their respective advantages and limitations. Recent advances in imaging technologies provide evaluation that is more accurate for tumor localization, morphology, physiology, and biology. When used in combination, these technologies provide clinicians with a powerful diagnostic and prognostic tool for managing metastatic brain disease.
Collapse
Affiliation(s)
- Robert J Young
- Department of Radiology, Division of Neuroradiology, New York University School of Medicine, New York, New York, USA
| | | | | | | |
Collapse
|
18
|
Antonsson J, Eriksson O, Wårdell K. Radio frequency electrode system for optical lesion size estimation in functional neurosurgery. JOURNAL OF BIOMEDICAL OPTICS 2005; 10:034020. [PMID: 16229664 DOI: 10.1117/1.1924615] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Radiofrequency (RF) lesioning in the human brain is one possible surgical therapy for severe pain as well as movement disorders. One obstacle for a safer lesioning procedure is the lack of size monitoring. The aim of this study was to investigate if changes in laser Doppler or intensity signals could be used as markers for size estimation during experimental RF lesioning. A 2 mm in diameter monopolar RF electrode was equipped with optical fibers and connected to a digital laser Doppler system. The optical RF electrode's performance was equal to a standard RF electrode with the same dimensions. An albumin solution with scatterers was used to evaluate the intensity and laser Doppler signal changes during lesioning at 70, 80, and 90 degrees C. Significant signal changes were found for these three different clot sizes, represented by the temperatures (p<0.05, n=10). The volume, width, and length of the created coagulations were correlated to the intensity signal changes (r=0.88, n=30, p<0.0001) and to the perfusion signal changes (r=0.81, n=30, p<0.0001). Both static and Doppler-shifted light can be used to follow the lesioning procedure as well as being used for lesion size estimation during experimental RF lesioning.
Collapse
Affiliation(s)
- Johan Antonsson
- Linköpings Universitet, Department of Biomedical Engineering, Sweden.
| | | | | |
Collapse
|
19
|
Abstract
MRI-guided neurosurgery not only represents a technical challenge but a transformation from conventional hand-eye coordination to interactive navigational operations. In the future, multimodality-based images will be merged into a single model, in which anatomy and pathologic changes are at once distinguished and integrated into the same intuitive framework. The long-term goals of improving surgical procedures and attendant outcomes, reducing costs, and achieving broad use can be achieved with a three-pronged approach: 1. Improving the presentation of preoperative and real-time intraoperative image information 2. Integrating imaging and treatment-related technology into therapy delivery systems 3. Testing the clinical utility of image guidance in surgery The recent focus in technology development is on improving our ability to understand and apply medical images and imaging systems. Areas of active research include image processing, model-based image analysis, model deformation, real-time registration, real-time 3D (so-called "four-dimensional") imaging, and the integration and presentation of image and sensing information in the operating room. Key elements of the technical matrix also include visualization and display platforms and related software for information and display, model-based image understanding, the use of computing clusters to speed computation (ie, algorithms with partitioned computation to optimize performance), and advanced devices and systems for 3D device tracking (navigation). Current clinical applications are successfully incorporating real-time and/or continuously up-dated image-based information for direct intra-operative visualization. In addition to using traditional imaging systems during surgery, we foresee optimized use of molecular marker technology, direct measures of tissue characterization (ie, optical measurements and/or imaging), and integration of the next generation of surgical and therapy devices (including image-guided robotic systems). Although we expect the primary clinical thrusts of MRI-guided therapy to remain in neurosurgery, with the possible addition of other areas like orthopedic, head, neck, and spine surgery, we also anticipate increased use of image-guided focal thermal ablative methods (eg, laser, RF, cryoablation, high-intensity focused ultrasound). By validating the effectiveness of MRI-guided therapy in specific clinical procedures while refining the technology that serves as its underpinning at the same time, we expect many neurosurgeons will eventually embrace MRI as their intraoperative imaging choice. Clearly, intraoperative MRI offers several palpable advantages. Most important among these are improved medical outcomes, shorter hospitalization, and better and faster procedures with fewer complications. Certain economic and practical barriers also impede the large-scale use of intraoperative MRI. Although there has been a concerted technical effort to increase the benefit/cost ratio by gathering more accurate information, designing more localized and less invasive treatment devices, and developing better methods to orient and position therapy end-effectors, further research is needed. Indeed, the drive to improve and upgrade technology is ongoing. Specifically, in the context of the real-time representation of the patient's anatomy, we have improved the quality and utility of the information presented to the surgeon, which, in turn, contributes to more successful surgical outcomes. We can also expect improvements in intraoperative imaging systems as well as increased use of nonimaging sensors and robotics to facilitate more widespread use of intraoperative MRI.
Collapse
Affiliation(s)
- Ferenc A Jolesz
- Division of MRI and Image Guided Therapy Program, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA.
| |
Collapse
|
20
|
Abstract
DTI seems to offer the possibility of adding important information to presurgical planning. Although experience is limited, DTI seems to provide useful local information about the structures near the tumor, and this seems to be useful in planning. In the future, DTI may provide an improved way to monitor intraoperative surgical procedures as well as their complications. Furthermore, evaluation of the response to treatment with chemotherapy and radiation therapy might also be possible. Although DTI has some limitations, its active investigation and further study are clearly warranted.
Collapse
Affiliation(s)
- L Celso Hygino Cruz Júnior
- Clínica de Diagnóstico por Imagem, Multi-Imagem Ressonância Magnética, Av. das Ameréricas 4666, Centro Médico Barrashopping, Rio de Janeiro, Brazil
| | | |
Collapse
|
21
|
Nimsky C, Ganslandt O, Hastreiter P, Wang R, Benner T, Sorensen AG, Fahlbusch R. Intraoperative diffusion-tensor MR imaging: shifting of white matter tracts during neurosurgical procedures--initial experience. Radiology 2004; 234:218-25. [PMID: 15564394 DOI: 10.1148/radiol.2341031984] [Citation(s) in RCA: 149] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively evaluate the location of white matter tracts with diffusion-tensor imaging (DTI) during neurosurgical procedures. MATERIALS AND METHODS Ethical committee approval and signed informed consent were obtained. A 1.5-T magnetic resonance imager with an adapted rotating surgical table that is placed in a radiofrequency-shielded operating theater was used for pre- and intraoperative imaging. DTI was performed by applying an echo-planar imaging sequence with six diffusion directions in 38 patients (20 female patients, 18 male patients; age range, 7-77 years; mean age, 45.6 years) who were undergoing surgery (35 craniotomy and three burr hole procedures). Color-encoded maps of fractional anisotropy were generated by depicting white matter tracts. A rigid registration algorithm was used to compare pre- and intraoperative images. RESULTS Intraoperative DTI was technically feasible in all patients, and no major image distortions occurred in the areas of interest. Pre- and intraoperative color-encoded maps of fractional anisotropy could be registered; these maps depicted marked and highly variable shifting of white matter tracts during neurosurgical procedures. In the 27 patients who underwent brain tumor resection, white matter tract shifting ranged from an inward shift of 8 mm to an outward shift of 15 mm (mean shift +/- standard deviation, outward shift of 2.5 mm +/- 5.8). In 16 (59%) of 27 patients, outward shifting was detected; in eight (30%), inward shifting was detected. In eight patients who underwent temporal lobe resections for drug-resistant epilepsy, shifting was only inward and ranged from 2 to 14 mm (9 mm +/- 3.3). In two of the three patients who underwent burr hole procedures, outward shifting occurred. CONCLUSION Intraoperative DTI can depict shifting of major white matter tracts that is caused by surgical intervention.
Collapse
Affiliation(s)
- Christopher Nimsky
- Department of Neurosurgery, University Erlangen-Nürnberg, Schwabachanlage 6, 91054 Erlangen, Germany.
| | | | | | | | | | | | | |
Collapse
|
22
|
Abstract
Of all the advances in imaging science in the past twenty years, none has had a greater impact than Magnetic Resonance Imaging. Since its introduction as a diagnostic tool in the mid-1980's, MRI has evolved into the premier neuroimaging modality, and with the addition of higher field magnets, we are able to achieve spatial resolution of such superb quality that even the most exquisite details of the brain anatomy can be visualized. With the implementation of intraoperative, neurosurgical MRI, we can not only monitor brain shifts and deformations; we can achieve intraoperative navigation using intraoperative image updates. In the future, intraoperative MRI can be used not only to localize, target, and resect brain tumors and other lesions but also to fully comprehend the surrounding cortical and white matter functional anatomy. In addition to the inclusion of new imaging methods such as diffusion tensor imaging, new therapeutic methods will be applied. Especially encouraging are the promising results in MRI-guided Focused Ultrasound Surgery, in which the non-invasive thermal ablation of tumors is monitored and controlled by MRI. With the clinical introduction of these advances, intraoperative MRI is changing the face of Neurosurgery today.
Collapse
Affiliation(s)
- F A Jolesz
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
23
|
Maier SE, Mamata H, Mulkern RV. Characterization of normal brain and brain tumor pathology by chisquares parameter maps of diffusion-weighted image data. Eur J Radiol 2003; 45:199-207. [PMID: 12595104 DOI: 10.1016/s0720-048x(02)00308-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE To characterize normal and pathologic brain tissue by quantifying the deviation of diffusion-related signal from a simple monoexponential decay, when measured over a wider than usual range of b-factors. METHODS AND MATERIALS Line scan diffusion imaging (LSDI), with diffusion weighting at multiple b-factors between 100 and 5000 s/mm(2), was performed on 1.5 T clinical scanners. Diffusion data of single slice sections were acquired in five healthy subjects and 19 brain tumor patients. In-patients, conventional T2-weighted and contrast-enhanced T1-weighted images were obtained for reference purposes. The chisquare (chi(2)) error parameter associated with the monoexponential fits of the measured tissue water signals was then used to quantify the departure from a simple monoexponential signal decay on a pixel-by-pixel basis. RESULTS Diffusion-weighted images over a wider b-factor range than typically used were successfully obtained in all healthy subjects and patients. Normal and pathologic tissues demonstrated signal decays, which clearly deviate from a simple monoexponential behavior. The chi(2) of cortical and deep grey matter was considerably lower than in white matter. In peritumoral edema, however, chi(2) was 68% higher than in normal white matter. In highly malignant brain tumors, such as glioblastoma multiforme (GBM) or anaplastic astrocytoma, chi(2) values were on average almost 400% higher than in normal white matter, while for one low grade astrocytoma and two cases of metastasis, chi(2) was not profoundly different from the chi(2) value of white matter. Maps of the chi(2) values provide good visualization of spatial details. However, the tumor tissue contrast generated appeared in many cases to be different from the enhancement produced by paramagnetic contrast agents. For example, in cases where the contrast agent only highlighted the rim of the tumor, chi(2) enhancement was present within the solid part of the tumor. CONCLUSION The deviation from a purely monoexponential diffusion signal decay becomes evident as diffusion encoding is extended well beyond the normal range. The chi(2) error parameter as a measure of this deviation seems to provide sufficient lesion contrast to permit differentiation of malignant brain tumors from normal brain tissue.
Collapse
Affiliation(s)
- Stephan E Maier
- Department of Radiology (MRI), Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA.
| | | | | |
Collapse
|
24
|
|
25
|
Jolesz FA, Talos IF, Schwartz RB, Mamata H, Kacher DF, Hynynen K, McDannold N, Saivironporn P, Zao L. Intraoperative magnetic resonance imaging and magnetic resonance imaging-guided therapy for brain tumors. Neuroimaging Clin N Am 2002; 12:665-83. [PMID: 12687918 DOI: 10.1016/s1052-5149(02)00036-9] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Since their introduction into surgical practice in the mid 1990s, intraoperative MRI systems have evolved into essential, routinely used tools for the surgical treatment of brain tumors in many centers. Clear delineation of the lesion, "under-the-surface" vision, and the possibility of obtaining real-time feedback on the extent of resection and the position of residual tumor tissue (which may change during surgery due to "brain-shift") are the main strengths of this method. High-performance computing has further extended the capabilities of intraoperative MRI systems, opening the way for using multimodal information and 3D anatomical reconstructions, which can be updated in "near real time." MRI sensitivity to thermal changes has also opened the way for innovative, minimally invasive (LASER ablations) as well as noninvasive therapeutic approaches for brain tumors (focused ultrasound). Although we have not used intraoperative MRI in clinical applications sufficiently long to assess long-term outcomes, this method clearly enhances the ability of the neurosurgeon to navigate the surgical field with greater accuracy, to avoid critical anatomic structures with greater efficacy, and to reduce the overall invasiveness of the surgery itself.
Collapse
Affiliation(s)
- Ferenc A Jolesz
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Abstract
Intraoperative magnetic resonance imaging (iMRI) is a new development in medicine that bridges the specialties of surgery and radiology. Deficiencies in the visualization of anatomical architecture and the perception of tumour boundaries in conventional open surgery have led to the integration of imaging within surgery. The superior soft tissue and multiplanar imaging features of magnetic resonance (MR) make this imaging modality superior to that of alternatives. The unique properties of MR to detect heat change and perfusion, and diffusion characteristics of tissue enhance the usefulness of this medium. Concurrent developments in computer aided image guidance and thermoablative technology, herald the era of minimally invasive tumour ablation. Applications have been developed for areas such as neurosurgery, general surgery, gynaecology and urology.
Collapse
Affiliation(s)
- Laurence Gluch
- Magnetic Resonance Therapy Unit, Brigham and Womens' Hospital, Boston, Massachusetts, USA.
| | | |
Collapse
|
27
|
Abstract
For maximum robustness of a diffusion-weighted MR imaging sequence, it is desirable to use a single-shot imaging method. This article introduces a new single-shot imaging approach that combines the advantages of multiple spin-echoes with the technique of line scan diffusion imaging. A slab volume, which can be spatially encoded with fewer phase encodes than a regular field of view, is selected with 2D selective pulses. With the shorter echo train, the sensitivity to field inhomogeneities and chemical shift is thus greatly diminished. Further reduction is achieved by interleaving short gradient echo trains with refocusing spin-echo pulses. Optimized slice-selective RF pulses that produce flip angles close to 180 degrees are used to minimize the stimulated echo component. Motion-related phase shifts, which change polarity with each spin-echo excitation, will give rise to artifacts that are avoidable by processing even and odd spin-echoes separately. As with line scan diffusion imaging, the complete field of view is acquired by sequential scanning. Since with each shot several lines of data are collected, a considerable improvement over line scan diffusion imaging in terms of scanning speed is achieved. Diffusion data obtained in phantoms and normal subjects demonstrate the feasibility of this novel approach.
Collapse
Affiliation(s)
- S E Maier
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115, USA.
| |
Collapse
|