Wei S, Richard R, Hogue D, Mondal I, Xu T, Boyer T, Hamilton K. High resolution data visualization and machine learning prediction of free chlorine residual in a green building water system. WATER RESEARCH X 2024; 24:100244. [PMID: 39188328 PMCID: PMC11345929 DOI: 10.1016/j.wroa.2024.100244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 07/23/2024] [Accepted: 07/25/2024] [Indexed: 08/28/2024]
Abstract
People spend most of their time indoors and are exposed to numerous contaminants in the built environment. Water management plans implemented in buildings are designed to manage the risks of preventable diseases caused by drinking water contaminants such as opportunistic pathogens (e.g., Legionella spp.), metals, and disinfection by-products (DBPs). However, specialized training required to implement water management plans and heterogeneity in building characteristics limit their widespread adoption. Implementation of machine learning and artificial intelligence (ML/AI) models in building water settings presents an opportunity for faster, more widespread use of data-driven water quality management approaches. We demonstrate the utility of Random Forest and Long Short-Term Memory (LSTM) ML models for predicting a key public health parameter, free chlorine residual, as a function of data collected from building water quality sensors (ORP, pH, conductivity, and temperature) as well as WiFi signals as a proxy for building occupancy and water usage in a "green" Leadership in Energy and Environmental Design (LEED) commercial and institutional building. The models successfully predicted free chlorine residual declines below 0.2 ppm, a common minimum reference level for public health protection in drinking water distribution systems. The predictions were valid up to 5 min in advance, and in some cases reasonably accurate up to 24 h in advance, presenting opportunities for proactive water quality management as part of a sense-analyze-decide framework. An online data dashboard for visualizing water quality in the building is presented, with the potential to link these approaches for real-time water quality management.
Collapse
Affiliation(s)
- S. Wei
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, United States
| | - R. Richard
- Wilson & Company Engineers, United States
| | - D. Hogue
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, United States
| | - I. Mondal
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, United States
- Biodesign Center for Environmental Health Engineering, Arizona State University, Tempe, AZ 85281, United States
| | - T. Xu
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, United States
| | - T.H. Boyer
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, United States
| | - K.A. Hamilton
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, United States
- Biodesign Center for Environmental Health Engineering, Arizona State University, Tempe, AZ 85281, United States
| |
Collapse
|
2
|
Schubert A, Harrison J, Kent-Buchanan L, Bonds V, McElmurry SP, Love NG. A point-of-use drinking water quality dataset from fieldwork in Detroit, Michigan. Sci Data 2024; 11:443. [PMID: 38702401 PMCID: PMC11068869 DOI: 10.1038/s41597-024-03298-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 04/23/2024] [Indexed: 05/06/2024] Open
Abstract
Drinking water quality sensor technology has rapidly advanced, facilitating the collection of rich datasets and real-time analytics. However, sensors have not yet been widely applied to monitor drinking water quality in premise plumbing. Richer quality of data in premise plumbing offers an improved understanding of the quality of drinking water present at the point-of-use. In this paper, online drinking water quality sensor nodes were temporarily installed in twenty-four homes in Detroit, Michigan. The water quality sensor nodes took measurements of five drinking water quality parameters every five minutes for four weeks. Additionally, free chlorine and lead were sampled periodically within each home. Together, these data make up a dataset that captures drinking water quality over time in a legacy city with an oversized drinking water system. This dataset offers more frequent measurements amongst more sample homes than are typically available in premise plumbing or at the tap. The data can be used to investigate temporal trends in drinking water quality, including diurnal patterns and anomaly detection. Additionally, this dataset could be utilized to evaluate water quality in comparison with other cities.
Collapse
Affiliation(s)
- Alyssa Schubert
- University of Michigan, Department of Civil and Environmental Engineering, Ann Arbor, USA
| | - Jacob Harrison
- University of Michigan, Department of Civil and Environmental Engineering, Ann Arbor, USA
| | | | | | - Shawn P McElmurry
- Wayne State University, Department of Civil and Environmental Engineering, Detroit, USA
| | - Nancy G Love
- University of Michigan, Department of Civil and Environmental Engineering, Ann Arbor, USA.
| |
Collapse
|
3
|
Clements E, Crank K, Nerenberg R, Atkinson A, Gerrity D, Hannoun D. Quantitative Microbial Risk Assessment Framework Incorporating Water Ages with Legionella pneumophila Growth Rates. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:6540-6551. [PMID: 38574283 PMCID: PMC11025131 DOI: 10.1021/acs.est.4c01208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 03/20/2024] [Accepted: 03/21/2024] [Indexed: 04/06/2024]
Abstract
Water age in drinking water systems is often used as a proxy for water quality but is rarely used as a direct input in assessing microbial risk. This study directly linked water ages in a premise plumbing system to concentrations of Legionella pneumophila via a growth model. In turn, the L. pneumophila concentrations were used for a quantitative microbial risk assessment to calculate the associated probabilities of infection (Pinf) and clinically severe illness (Pcsi) due to showering. Risk reductions achieved by purging devices, which reduce water age, were also quantified. The median annual Pinf exceeded the commonly used 1 in 10,000 (10-4) risk benchmark in all scenarios, but the median annual Pcsi was always 1-3 orders of magnitude below 10-4. The median annual Pcsi was lower in homes with two occupants (4.7 × 10-7) than with one occupant (7.5 × 10-7) due to more frequent use of water fixtures, which reduced water ages. The median annual Pcsi for homes with one occupant was reduced by 39-43% with scheduled purging 1-2 times per day. Smart purging devices, which purge only after a certain period of nonuse, maintained these lower annual Pcsi values while reducing additional water consumption by 45-62%.
Collapse
Affiliation(s)
- Emily Clements
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Katherine Crank
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Robert Nerenberg
- Department
of Civil & Environmental Engineering & Earth Science, University of Notre Dame, 156 Fitzpatrick Hall, Notre
Dame, Indiana 46556, United States
| | - Ariel Atkinson
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Daniel Gerrity
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Deena Hannoun
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| |
Collapse
|
4
|
Ra K, Proctor C, Ley C, Angert D, Noh Y, Odimayomi T, Whelton AJ. Four buildings and a flush: Lessons from degraded water quality and recommendations on building water management. ENVIRONMENTAL SCIENCE AND ECOTECHNOLOGY 2024; 18:100314. [PMID: 37854462 PMCID: PMC10579424 DOI: 10.1016/j.ese.2023.100314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 09/07/2023] [Accepted: 09/11/2023] [Indexed: 10/20/2023]
Abstract
A reduction in building occupancy can lead to stagnant water in plumbing, and the potential consequences for water quality have gained increasing attention. To investigate this, a study was conducted during the COVID-19 pandemic, focusing on water quality in four institutional buildings. Two of these buildings were old (>58 years) and large (>19,000 m2), while the other two were new (>13 years) and small (<11,000 m2). The study revealed significant decreases in water usage in the small buildings, whereas usage remained unchanged in the large buildings. Initial analysis found that residual chlorine was rarely detectable in cold/drinking water samples. Furthermore, the pH, dissolved oxygen, total organic carbon, and total cell count levels in the first draw of cold water samples were similar across all buildings. However, the ranges of heavy metal concentrations in large buildings were greater than observed in small buildings. Copper (Cu), lead (Pb), and manganese (Mn) sporadically exceeded drinking water limits at cold water fixtures, with maximum concentrations of 2.7 mg Cu L-1, 45.4 μg Pb L-1, 1.9 mg Mn L-1. Flushing the plumbing for 5 min resulted in detectable residual at fixtures in three buildings, but even after 125 min of flushing in largest and oldest building, no residual chlorine was detected at the fixture closest to the building's point of entry. During the pandemic, the building owner conducted fixture flushing, where one to a few fixtures were operated per visit in buildings with hundreds of fixtures and multiple floors. However, further research is needed to understand the fundamental processes that control faucet water quality from the service line to the faucet. In the absence of this knowledge, building owners should create and use as-built drawings to develop flushing plans and conduct periodic water testing.
Collapse
Affiliation(s)
- Kyungyeon Ra
- Lyles School of Civil Engineering, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN, 47907, USA
| | - Caitlin Proctor
- Agricultural and Biological Engineering, Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Christian Ley
- Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Civil and Environmental Engineering, University of Colorado, 1111 Engineering Drive, Boulder, CO, 80309, USA
| | - Danielle Angert
- Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Civil, Architectural and Environmental Engineering, University of Texas, 301E E Dean Keeton Street, Austin, TX, 78712, USA
| | - Yoorae Noh
- Lyles School of Civil Engineering, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN, 47907, USA
| | - Tolulope Odimayomi
- Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Civil and Environmental Engineering, Virginia Tech, 750 Drillfield Drive, Blacksburg, VA, 24061, USA
| | - Andrew J. Whelton
- Lyles School of Civil Engineering, Division of Environmental and Ecological Engineering, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN, 47907, USA
| |
Collapse
|
5
|
Martinez Paz EF, Raskin L, Wigginton KR, Kerkez B. Toward the autonomous flushing of building plumbing: Characterizing oxidation-reduction potential and temperature sensor dynamics. WATER RESEARCH 2024; 251:121098. [PMID: 38219686 DOI: 10.1016/j.watres.2023.121098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 12/05/2023] [Accepted: 12/30/2023] [Indexed: 01/16/2024]
Abstract
Manual flushing of building plumbing is commonly used to address water quality issues that arise from water stagnation. Autonomous flushing informed by sensors has the potential to aid in the management of building plumbing, but a number of knowledge gaps hinder its application. This study evaluates autonomous flushing of building plumbing with online sensor and actuator nodes deployed under kitchen sinks in five residential houses. Online oxidation-reduction potential (ORP) and temperature data were collected for nine weeks during the winter and summer in houses with both free chlorine and chloramine. ORP levels in houses with free chlorine residuals decreased after overnight stagnation. The overnight decrease in ORP was not observed when tap water was automatically flushed for five minutes at 6:00 h every morning. ORP levels in houses with chloramine residuals did not decrease consistently after overnight stagnation, and daily automated flushes did not have an observable effect on the ORP signals. Additional laboratory experiments were carried out to evaluate ORP signals during chlorine decay and after incremental changes in chlorine, as would be expected in building plumbing conditions. Results from the lab and field deployments suggest on-line ORP sensors may be used to detect free chlorine decay due to stagnating water, but are not as effective in detecting chloramine decay. However, field results also suggest ORP may not respond as expected on a timely manner after free chlorine or chloramine have been restored, hindering their applicability in developing control algorithms. In this paper we tested twice-daily five-minute automatic flushing and found that it counteracts water quality degradation associated with overnight stagnation in free chlorine systems. An automatic sensor-based flushing is proposed using online temperature sensor data to determine when flushing has reached water from the main. The results suggest that flushing informed by temperature sensors can reduce the flushing time by 46 % compared to the preset five-minute static flush.
Collapse
Affiliation(s)
- Ernesto F Martinez Paz
- Department of Civil and Environmental Engineering, University of Michigan, 2350 Hayward Ave., 2044 GG Brown, Ann Arbor, MI 48109, USA
| | - Lutgarde Raskin
- Department of Civil and Environmental Engineering, University of Michigan, 2350 Hayward Ave., 2044 GG Brown, Ann Arbor, MI 48109, USA
| | - Krista R Wigginton
- Department of Civil and Environmental Engineering, University of Michigan, 2350 Hayward Ave., 2044 GG Brown, Ann Arbor, MI 48109, USA.
| | - Branko Kerkez
- Department of Civil and Environmental Engineering, University of Michigan, 2350 Hayward Ave., 2044 GG Brown, Ann Arbor, MI 48109, USA.
| |
Collapse
|
6
|
Clements E, Irwin C, Taflanidis A, Bibby K, Nerenberg R. Impact of fixture purging on water age and excess water usage, considering stochastic water demands. WATER RESEARCH 2023; 245:120643. [PMID: 37748346 DOI: 10.1016/j.watres.2023.120643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 09/13/2023] [Accepted: 09/17/2023] [Indexed: 09/27/2023]
Abstract
Higher water ages are linked with water quality decline as chlorine dissipates, temperatures become more favorable for microbial growth, and metals and organic matter leach from the pipes. Water fixtures with automated purging devices can limit water age in premise plumbing systems, but also increase water use. To develop purging strategies that lower age while also minimizing water use, the stochastic nature of water demands must be considered. In this research, a hydraulic plumbing network model, with stochastic demands at fixtures, was used to compare water age and water use for five purging conditions: purging at regular intervals, "smart" purging (considering the time of last use), purging with different volumes of water, purging at different fixtures, and the purging with different levels of home occupancy. Higher purging frequency and volume resulted in lower water ages, but higher water use. Purging greatly reduced the variability in water ages, avoiding extreme ages entirely. Water age was minimized by scheduling the purging around occupancy behavior, such as before the occupants wake up or return from work. Scheduled purging used more water than smart purging. Purging after 12 h of nonuse used only 55% of the additional water required for purging every 12 h. Purging after 24 h of nonuse at the kitchen tap and shower used only 38% of the additional water required for purging every 24 h, while maintaining lower water ages and removing the variability in water ages. While larger purging volumes had a greater impact on water age, there were diminishing returns. Purging has a larger impact on low-occupancy homes because fixtures have less frequent use. Overall, this research provides a methodology to compare purging strategies that minimize both water age and water use. While the numerical results presented here are only valid for the specific layout and usage habits, they provide insights and trends applicable to other cases.
Collapse
Affiliation(s)
- Emily Clements
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Christopher Irwin
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Alexandros Taflanidis
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Kyle Bibby
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Robert Nerenberg
- Department of Civil and Environmental Engineering and Earth Sciences 156 Fitzpatrick Hall, University of Notre Dame, Notre Dame, IN 46556, USA.
| |
Collapse
|
7
|
Hatam F, Blokker M, Doré E, Prévost M. Reduction in water consumption in premise plumbing systems: Impacts on lead concentration under different water qualities. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 879:162975. [PMID: 36965725 DOI: 10.1016/j.scitotenv.2023.162975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 03/14/2023] [Accepted: 03/17/2023] [Indexed: 05/17/2023]
Abstract
Water conservation measures are increasing in response to regulatory requirements addressing the need for lower environmental footprint and in response to water shortages. In households with lead service lines (LSLs), lowering consumption can adversely impact lead release as it will increase stagnation. Using a lead dissolution model and data from extensive pilot studies on excavated LSLs, the impact of adaptation to different water conservation strategies on dissolved lead contamination at the kitchen tap is assessed under three water qualities and three LSL lengths (3, 14 and 30 m) using hydraulic and water quality modelling. Consumers' behavioural variability is also assessed based on integration of EPANET and results of the stochastic water demand model SIMDEUM. Demand reduction increased the dissolved lead concentrations (Pbdiss) at the end of the LSL with mean values ranging from 28.4 to 63.3 μg/L (without corrosion control) and from 4.6 to 9.9 μg/L with corrosion control (addition of orthophosphate and pH adjustment). Adding orthophosphate (1 mg P/L) to the water reduces the mean Pbdiss values at the kitchen tap from 7.1 μg/L to 1.2 μg/L for a high water demand scenario and from 31.2 to 4.9 μg/L for a low water demand scenario. Finally, the Integrated Exposure Uptake Biokinetic (IEUBK) model is used to predict the potential blood lead levels (BLLs) for children aged 0-84 months. Results showed that the orthophosphate addition of only 1 mg P/L can significantly decrease the proportion of children with a BLL >5 μg/dL, from 82 % to 17 %, under the most extreme water conservation scenario studied, using the 90th percentile of Pbdiss concentrations during usage at kitchen tap. Wide variations of Pbdiss concentrations at the kitchen tap were calculated at times of use over a week (up to 155 μg/L in lower demand scenarios, without corrosion control) showing evident limitations of single random daytime sampling.
Collapse
Affiliation(s)
- Fatemeh Hatam
- Industrial Chair on Drinking Water, Department of Civil, Geological and Mining Engineering, Polytechnique Montréal, CP 6079, Succ. Centre-ville, Montréal, QC H3C 3A7, Canada.
| | - Mirjam Blokker
- KWR Watercycle Research Institute, Groningenhaven 7, 3433 PE Nieuwegein, the Netherlands
| | - Evelyne Doré
- Industrial Chair on Drinking Water, Department of Civil, Geological and Mining Engineering, Polytechnique Montréal, CP 6079, Succ. Centre-ville, Montréal, QC H3C 3A7, Canada
| | - Michèle Prévost
- Industrial Chair on Drinking Water, Department of Civil, Geological and Mining Engineering, Polytechnique Montréal, CP 6079, Succ. Centre-ville, Montréal, QC H3C 3A7, Canada
| |
Collapse
|
8
|
Yao M, Zhang Y, Dai Z, Ren A, Fang J, Li X, van der Meer W, Medema G, Rose JB, Liu G. Building water quality deterioration during water supply restoration after interruption: Influences of premise plumbing configuration. WATER RESEARCH 2023; 241:120149. [PMID: 37270942 DOI: 10.1016/j.watres.2023.120149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 05/26/2023] [Accepted: 05/28/2023] [Indexed: 06/06/2023]
Abstract
Premise plumbing plays an essential role in determining the final quality of drinking water consumed by customers. However, little is known about the influences of plumbing configuration on water quality changes. This study selected parallel premise plumbing in the same building with different configurations, i.e., laboratory and toilet plumbing. Water quality deteriorations induced by premise plumbing under regular and interrupted water supply were investigated. The results showed that most of the water quality parameters did not vary under regular supply, except Zn, which was significantly increased by laboratory plumbing (78.2 to 260.7 µg/l). For the bacterial community, the Chao1 index was significantly increased by both plumbing types to a similar level (52 to 104). Laboratory plumbing significantly changed the bacterial community, but toilet plumbing did not. Remarkably, water supply interruption/restoration led to serious water quality deterioration in both plumbing types but resulted in different changes. Physiochemically, discoloration was observed only in laboratory plumbing, along with sharp increases in Mn and Zn. Microbiologically, the increase in ATP was sharper in toilet plumbing than in laboratory plumbing. Some opportunistic pathogen-containing genera, e.g., Legionella spp. and Pseudomonas spp., were present in both plumbing types but only in disturbed samples. This study highlighted the esthetic, chemical, and microbiological risks associated with premise plumbing, for which system configuration plays an important role. Attention should be given to optimizing premise plumbing design for managing building water quality.
Collapse
Affiliation(s)
- Mingchen Yao
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China; Sanitary engineering, Department of Water management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, Delft, GA 2600, the Netherlands
| | - Yue Zhang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China
| | - Zihan Dai
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China
| | - Anran Ren
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China
| | - Jiaxing Fang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Membrane Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, Enschede 7500AE, the Netherlands
| | - Xiaoming Li
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China
| | - Walter van der Meer
- Membrane Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, Enschede 7500AE, the Netherlands; Oasen Drinkwater, PO BOX 122, Gouda, AC 2800, the Netherlands
| | - Gertjan Medema
- Sanitary engineering, Department of Water management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, Delft, GA 2600, the Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, Nieuwegein 3430 BB, the Netherlands; Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, United States of America
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, United States of America
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China.
| |
Collapse
|
9
|
Logan-Jackson AR, Batista MD, Healy W, Ullah T, Whelton AJ, Bartrand TA, Proctor C. A Critical Review on the Factors that Influence Opportunistic Premise Plumbing Pathogens: From Building Entry to Fixtures in Residences. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:6360-6372. [PMID: 37036108 DOI: 10.1021/acs.est.2c04277] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Residential buildings provide unique conditions for opportunistic premise plumbing pathogen (OPPP) exposure via aerosolized water droplets produced by showerheads, faucets, and tubs. The objective of this review was to critically evaluate the existing literature that assessed the impact of potentially enhancing conditions to OPPP occurrence associated with residential plumbing and to point out knowledge gaps. Comprehensive studies on the topic were found to be lacking. Major knowledge gaps identified include the assessment of OPPP growth in the residential plumbing, from building entry to fixtures, and evaluation of the extent of the impact of typical residential plumbing design (e.g., trunk and branch and manifold), components (e.g., valves and fixtures), water heater types and temperature setting of operation, and common pipe materials (copper, PEX, and PVC/CPVC). In addition, impacts of the current plumbing code requirements on OPPP responses have not been assessed by any study and a lack of guidelines for OPPP risk management in residences was identified. Finally, the research required to expand knowledge on OPPP amplification in residences was discussed.
Collapse
Affiliation(s)
- Alshae' R Logan-Jackson
- Building Energy and Environment Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Marylia Duarte Batista
- Building Energy and Environment Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - William Healy
- Building Energy and Environment Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Tania Ullah
- Building Energy and Environment Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Andrew J Whelton
- Lyles School of Civil Engineering, Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Timothy A Bartrand
- Environmental Science, Policy, and Research Institute, Bala Cynwyd, Pennsylvania 19004, United States
| | - Caitlin Proctor
- Agricultural and Biological Engineering, Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
10
|
Schubert A, Pifer L, Cheng J, McElmurry SP, Kerkez B, Love NG. An Automated Toolchain for Camera-Enabled Sensing of Drinking Water Chlorine Residual. ACS ES&T ENGINEERING 2022; 2:1697-1708. [PMID: 36120115 PMCID: PMC9469768 DOI: 10.1021/acsestengg.2c00073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Chlorine residual concentration is an important parameter to prevent pathogen growth in drinking water. Disposable color changing test strips that measure chlorine in tap water are commercially available to the public; however, the color changes are difficult to read by eye, and the data are not captured for water service providers. Here we present an automated toolchain designed to process digital images of free chlorine residual test strips taken with mobile phone cameras. The toolchain crops the image using image processing algorithms that isolate the areas relevant for analysis and automatically white balances the image to allow for use with different phones and lighting conditions. The average red, green, and blue (RGB) color values of the image are used to predict a free chlorine concentration that is classified into three concentration tiers (<0.2 mg/L, 0.2-0.5 mg/L, or >0.5 mg/L), which can be reported to water users and recorded for utility use. The proposed approach was applied to three different phone types under three different lighting conditions using a standard background. This approach can discriminate between concentrations above and below 0.5 mg/L with an accuracy of 90% and 94% for training and testing data sets, respectively. Furthermore, it can discriminate between concentrations of <0.2 mg/L, 0.2-0.5 mg/L, or >0.5 mg/L with weighted-averaged F1 scores of 79% and 88% for training and testing data sets, respectively. This tool sets the stage for tap water consumers and water utilities to gather frequent measurements and high-resolution temporal and spatial data on drinking water quality.
Collapse
Affiliation(s)
- Alyssa Schubert
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Leah Pifer
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Jianzhong Cheng
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Shawn P. McElmurry
- Department
of Civil and Environmental Engineering, Wayne State University, Detroit, Michigan 48202, United States
| | - Branko Kerkez
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Nancy G. Love
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
11
|
Li J, Ren A, van der Mark E, Liu G. Direct evidence of microbiological water quality changes on bacterial quantity and community caused by plumbing system. J Environ Sci (China) 2022; 116:175-183. [PMID: 35219416 DOI: 10.1016/j.jes.2021.04.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 04/22/2021] [Accepted: 04/25/2021] [Indexed: 06/14/2023]
Abstract
Drinking water quality deteriorates from treatment plant to customer taps, especially in the plumbing system. There is no direct evidence about what the differences are contributed by plumbing system. This study compared the water quality in the water main and at customer tap by preparing a sampling tap on the water main. The biomass was quantified by adenosine triphosphate (ATP) and the microbial community was profiled by 454 pyrosequencing. The results showed that in distribution pipes, biofilm contributed >94% of the total biomass, while loose deposits showed little contribution (< 2%) because of the low amount of loose deposits. The distribution of biological stable water had minor effects on the microbiocidal water quality regarding both quantity (ATP 1 ng/L vs. 1.7 ng/L) and community of the bacteria. Whereas the plumbing system has significant contribution to the increase of active biomass (1.7 ng/L vs. 2.9 ng/L) and the changes of bacterial community. The relative abundance of Sphingomonas spp. at tap (22%) was higher than that at water main (2%), while the relative abundance of Pseudomonas spp. in tap water (15%) was lower than that in the water from street water main (29%). Though only one location was prepared and studied, the present study showed that the protocol of making sampling tap on water main offered directly evidences about the impacts of plumbing system on tap water quality, which makes it possible to distinguish and study the processes in distribution system and plumbing system separately.
Collapse
Affiliation(s)
- Jun Li
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Anran Ren
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ed van der Mark
- Dunea Water Company, Plaza of the United Nations 11-15, Zoetermeer 2700 AT, the Netherlands
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China; Sanitary engineering, Department of Water management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Delft 2600 GA, the Netherlands.
| |
Collapse
|
12
|
Proctor C, Garner E, Hamilton KA, Ashbolt NJ, Caverly LJ, Falkinham JO, Haas CN, Prevost M, Prevots DR, Pruden A, Raskin L, Stout J, Haig SJ. Tenets of a holistic approach to drinking water-associated pathogen research, management, and communication. WATER RESEARCH 2022; 211:117997. [PMID: 34999316 PMCID: PMC8821414 DOI: 10.1016/j.watres.2021.117997] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 12/13/2021] [Accepted: 12/19/2021] [Indexed: 05/10/2023]
Abstract
In recent years, drinking water-associated pathogens that can cause infections in immunocompromised or otherwise susceptible individuals (henceforth referred to as DWPI), sometimes referred to as opportunistic pathogens or opportunistic premise plumbing pathogens, have received considerable attention. DWPI research has largely been conducted by experts focusing on specific microorganisms or within silos of expertise. The resulting mitigation approaches optimized for a single microorganism may have unintended consequences and trade-offs for other DWPI or other interests (e.g., energy costs and conservation). For example, the ecological and epidemiological issues characteristic of Legionella pneumophila diverge from those relevant for Mycobacterium avium and other nontuberculous mycobacteria. Recent advances in understanding DWPI as part of a complex microbial ecosystem inhabiting drinking water systems continues to reveal additional challenges: namely, how can all microorganisms of concern be managed simultaneously? In order to protect public health, we must take a more holistic approach in all aspects of the field, including basic research, monitoring methods, risk-based mitigation techniques, and policy. A holistic approach will (i) target multiple microorganisms simultaneously, (ii) involve experts across several disciplines, and (iii) communicate results across disciplines and more broadly, proactively addressing source water-to-customer system management.
Collapse
Affiliation(s)
- Caitlin Proctor
- Department of Agricultural and Biological Engineering, Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, USA
| | - Emily Garner
- Wadsworth Department of Civil & Environmental Engineering, West Virginia University, Morgantown, WV, USA
| | - Kerry A Hamilton
- School of Sustainable Engineering and the Built Environment and The Biodesign Centre for Environmental Health Engineering, Arizona State University, Tempe, AZ, USA
| | - Nicholas J Ashbolt
- Faculty of Science and Engineering, Southern Cross University, Gold Coast. Queensland, Australia
| | - Lindsay J Caverly
- Department of Pediatrics, University of Michigan Medical School, Ann Arbor, MI, USA
| | | | - Charles N Haas
- Department of Civil, Architectural & Environmental Engineering, Drexel University, Philadelphia, PA, USA
| | - Michele Prevost
- Department of Civil, Geological and Mining Engineering, Polytechnique Montreal, Montreal, Quebec, Canada
| | - D Rebecca Prevots
- Epidemiology Unit, Laboratory of Clinical Immunology and Microbiology, Division of Intramural Research, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, MD, USA
| | - Amy Pruden
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, VA USA
| | - Lutgarde Raskin
- Department of Civil & Environmental Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Janet Stout
- Department of Civil & Environmental Engineering, University of Pittsburgh, and Special Pathogens Laboratory, Pittsburgh, PA, USA
| | - Sarah-Jane Haig
- Department of Civil & Environmental Engineering, and Department of Environmental & Occupational Health, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
13
|
Practitioners’ Perspective on the Prevalent Water Quality Management Practices for Legionella Control in Large Buildings in the United States. WATER 2022. [DOI: 10.3390/w14040663] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Managing building water systems is complicated by the need to maintain hot water temperatures high enough to control the growth of Legionella spp. while minimizing the risk of scalding. This study assessed water quality management practices in large buildings in the United States. Surveys conducted with building water quality managers found that more than 85% of buildings have hot water temperatures that are consistent with scald risk mitigation guidelines (i.e., <122 °F/50 °C). However, nearly two thirds and three quarters of buildings do not comply with the common temperature guidance for opportunistic pathogen control, i.e., water heater setpoint > 140 °F (60 °C) and recirculation loop > 122 °F (50 °C), respectively; median values for both setpoint and recirculation loop temperatures are 10 °F (6 °C) or more below temperatures recommended for opportunistic pathogen control. These observations suggest that many buildings are prone to Legionella spp. risk. The study also found that 27% of buildings do not comply with guidelines for time to equilibrium hot water temperature, over 33% fail to monitor temperature in the recirculation loop, more than 70% fail to replace or disinfect showerheads, more than 40% lack a written management plan, and only a minority conduct any monitoring of residual disinfectant levels or microbiological quality. Given the rise in Legionellosis infections in recent years, coupled with highlighted water quality concerns because of prolonged water stagnation in plumbing, such as in buildings closed due to COVID-19, current management practices, which appear to be focused on scald risk, may need to be broadened to include greater attention to control of opportunistic pathogens. To accomplish this, there is a need for formal training and resources for facility managers.
Collapse
|
14
|
Masaka E, Reed S, Davidson M, Oosthuizen J. Opportunistic Premise Plumbing Pathogens. A Potential Health Risk in Water Mist Systems Used as a Cooling Intervention. Pathogens 2021; 10:pathogens10040462. [PMID: 33921277 PMCID: PMC8068904 DOI: 10.3390/pathogens10040462] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 03/29/2021] [Accepted: 04/07/2021] [Indexed: 11/16/2022] Open
Abstract
Water mist systems (WMS) are used for evaporative cooling in public areas. The health risks associated with their colonization by opportunistic premise plumbing pathogens (OPPPs) is not well understood. To advance the understanding of the potential health risk of OPPPs in WMS, biofilm, water and bioaerosol samples (n = 90) from ten (10) WMS in Australia were collected and analyzed by culture and polymerase chain reaction (PCR) methods to detect the occurrence of five representative OPPPs: Legionella pneumophila, Pseudomonas aeruginosa, Mycobacterium avium, Naegleria fowleri and Acanthamoeba. P. aeruginosa (44%, n = 90) occurred more frequently in samples, followed by L. pneumophila serogroup (Sg) 2–14 (18%, n = 90) and L. pneumophila Sg 1 (6%, n = 90). A negative correlation between OPPP occurrence and residual free chlorine was observed except with Acanthamoeba, rs (30) = 0.067, p > 0.05. All detected OPPPs were positively correlated with total dissolved solids (TDS) except with Acanthamoeba. Biofilms contained higher concentrations of L. pneumophila Sg 2–14 (1000–3000 CFU/mL) than water samples (0–100 CFU/mL). This study suggests that WMS can be colonized by OPPPs and are a potential health risk if OPPP contaminated aerosols get released into ambient atmospheres.
Collapse
|
15
|
Proctor CR, Rhoads WJ, Keane T, Salehi M, Hamilton K, Pieper KJ, Cwiertny DM, Prévost M, Whelton AJ. Considerations for large building water quality after extended stagnation. AWWA WATER SCIENCE 2020; 2:e1186. [PMID: 32838226 DOI: 10.31219/osf.io/qvj3b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 06/03/2020] [Accepted: 06/09/2020] [Indexed: 05/25/2023]
Abstract
The unprecedented number of building closures related to the coronavirus disease (COVID-19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer-reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.
Collapse
Affiliation(s)
- Caitlin R Proctor
- Division of Environmental and Ecological Engineering, Lyles School of Civil Engineering, Weldon School of Biomedical Engineering, School of Materials Engineering Purdue University West Lafayette Indiana
| | - William J Rhoads
- Department of Civil and Environmental Engineering Virginia Tech Blacksburg Virginia
| | - Tim Keane
- Legionella Risk Management, Inc. Chalfont Pennsylvania
| | - Maryam Salehi
- Department of Civil Engineering University of Memphis Memphis Tennessee
| | - Kerry Hamilton
- School of Sustainable Engineering and the Built Environment Arizona State University Tempe Arizona
| | - Kelsey J Pieper
- Department of Civil and Environmental Engineering Northeastern University Boston Massachusetts
| | - David M Cwiertny
- Department of Civil and Environmental Engineering, Seamans Center for the Engineering Arts and Sciences University of Iowa Iowa City Iowa
- Center for Health Effects of Environmental Contamination University of Iowa Iowa City Iowa
- Public Policy Center University of Iowa Iowa City Iowa
| | - Michele Prévost
- Civil, Geological and Mining Engineering Polytechnique Montreal Montréal Québec Canada
| | - Andrew J Whelton
- Lyles School of Civil Engineering, Division of Environmental and Ecological Engineering Purdue University West Lafayette Indiana
| |
Collapse
|
16
|
Proctor CR, Rhoads WJ, Keane T, Salehi M, Hamilton K, Pieper KJ, Cwiertny DM, Prévost M, Whelton AJ. Considerations for Large Building Water Quality after Extended Stagnation. ACTA ACUST UNITED AC 2020; 2:e1186. [PMID: 32838226 PMCID: PMC7323006 DOI: 10.1002/aws2.1186] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 06/03/2020] [Accepted: 06/09/2020] [Indexed: 01/04/2023]
Abstract
The unprecedented number of building closures related to the coronavirus disease (COVID‐19) pandemic is concerning because water stagnation will occur in many buildings that do not have water management plans in place. Stagnant water can have chemical and microbiological contaminants that pose potential health risks to occupants. Health officials, building owners, utilities, and other entities are rapidly developing guidance to address this issue, but the scope, applicability, and details included in the guidance vary widely. To provide a primer of large building water system preventative and remedial strategies, peer‐reviewed, government, industry, and nonprofit literature relevant to water stagnation and decontamination practices for plumbing was synthesized. Preventative practices to help avoid the need for recommissioning (e.g., routine flushing) and specific actions, challenges, and limitations associated with recommissioning were identified and characterized. Considerations for worker and occupant safety were also indicated. The intended audience of this work includes organizations developing guidance.
Collapse
Affiliation(s)
- Caitlin R Proctor
- Division of Environmental and Ecological Engineering, Lyles School of Civil Engineering, Weldon School of Biomedical Engineering, School of Materials Engineering Purdue University West Lafayette IN
| | - William J Rhoads
- Department of Civil and Environmental Engineering Virginia Tech Blacksburg VA
| | - Tim Keane
- Consulting Engineer, Legionella Risk Management, Inc PA
| | - Maryam Salehi
- Department of Civil Engineering University of Memphis Memphis TN
| | - Kerry Hamilton
- School of Sustainable Engineering and the Built Environment Arizona State University Tempe AZ
| | - Kelsey J Pieper
- Department of Civil and Environmental Engineering Northeastern University Boston MA
| | - David M Cwiertny
- Department of Civil & Environmental Engineering, 4105 Seamans Center for the Engineering Arts and Sciences University of Iowa Iowa City IA.,Center for Health Effects of Environmental Contamination, 251 North Capitol Street, Chemistry Building - Room W195 University of Iowa Iowa City IA.,Public Policy Center, 310 South Grand Ave, 209 South Quadrangle University of Iowa Iowa City IA
| | - Michele Prévost
- Professor and Principal Chairholder, NSERC Industrial Chair on Drinking Water, Civil, Geological and Mining Engineering, Polytechnique Montreal CP Québec Canada
| | - Andrew J Whelton
- Purdue University, Lyles School of Civil Engineering, Division of Environmental and Ecological Engineering West Lafayette IN
| |
Collapse
|