1
|
Li L, Ding W, Huang L, Zhuang X, Grau V. Multi-modality cardiac image computing: A survey. Med Image Anal 2023; 88:102869. [PMID: 37384950 DOI: 10.1016/j.media.2023.102869] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 05/01/2023] [Accepted: 06/12/2023] [Indexed: 07/01/2023]
Abstract
Multi-modality cardiac imaging plays a key role in the management of patients with cardiovascular diseases. It allows a combination of complementary anatomical, morphological and functional information, increases diagnosis accuracy, and improves the efficacy of cardiovascular interventions and clinical outcomes. Fully-automated processing and quantitative analysis of multi-modality cardiac images could have a direct impact on clinical research and evidence-based patient management. However, these require overcoming significant challenges including inter-modality misalignment and finding optimal methods to integrate information from different modalities. This paper aims to provide a comprehensive review of multi-modality imaging in cardiology, the computing methods, the validation strategies, the related clinical workflows and future perspectives. For the computing methodologies, we have a favored focus on the three tasks, i.e., registration, fusion and segmentation, which generally involve multi-modality imaging data, either combining information from different modalities or transferring information across modalities. The review highlights that multi-modality cardiac imaging data has the potential of wide applicability in the clinic, such as trans-aortic valve implantation guidance, myocardial viability assessment, and catheter ablation therapy and its patient selection. Nevertheless, many challenges remain unsolved, such as missing modality, modality selection, combination of imaging and non-imaging data, and uniform analysis and representation of different modalities. There is also work to do in defining how the well-developed techniques fit in clinical workflows and how much additional and relevant information they introduce. These problems are likely to continue to be an active field of research and the questions to be answered in the future.
Collapse
Affiliation(s)
- Lei Li
- Department of Engineering Science, University of Oxford, Oxford, UK.
| | - Wangbin Ding
- College of Physics and Information Engineering, Fuzhou University, Fuzhou, China
| | - Liqin Huang
- College of Physics and Information Engineering, Fuzhou University, Fuzhou, China
| | - Xiahai Zhuang
- School of Data Science, Fudan University, Shanghai, China
| | - Vicente Grau
- Department of Engineering Science, University of Oxford, Oxford, UK
| |
Collapse
|
2
|
Grant EK, Kanter JP, Olivieri LJ, Cross RR, Campbell-Washburn A, Faranesh AZ, Cronin I, Hamann KS, O’Byrne ML, Slack MC, Lederman RJ, Ratnayaka K. X-ray fused with MRI guidance of pre-selected transcatheter congenital heart disease interventions. Catheter Cardiovasc Interv 2019; 94:399-408. [PMID: 31062506 PMCID: PMC6823111 DOI: 10.1002/ccd.28324] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 03/15/2019] [Accepted: 04/14/2019] [Indexed: 11/10/2022]
Abstract
OBJECTIVES To determine whether X-ray fused with MRI (XFM) is beneficial for select transcatheter congenital heart disease interventions. BACKGROUND Complex transcatheter interventions often require three-dimensional (3D) soft tissue imaging guidance. Fusion imaging with live X-ray fluoroscopy can potentially improve and simplify procedures. METHODS Patients referred for select congenital heart disease interventions were prospectively enrolled. Cardiac MRI data was overlaid on live fluoroscopy for procedural guidance. Likert scale operator assessments of value were recorded. Fluoroscopy time, radiation exposure, contrast dose, and procedure time were compared to matched cases from our institutional experience. RESULTS Forty-six patients were enrolled. Pre-catheterization, same day cardiac MRI findings indicated intervention should be deferred in nine patients. XFM-guided cardiac catheterization was performed in 37 (median age 8.7 years [0.5-63 years]; median weight 28 kg [5.6-110 kg]) with the following prespecified indications: pulmonary artery (PA) stenosis (n = 13), aortic coarctation (n = 12), conduit stenosis/insufficiency (n = 9), and ventricular septal defect (n = 3). Diagnostic catheterization showed intervention was not indicated in 12 additional cases. XFM-guided intervention was performed in the remaining 25. Fluoroscopy time was shorter for XFM-guided intervention cases compared to matched controls. There was no significant difference in radiation dose area product, contrast volume, or procedure time. Operator Likert scores indicated XFM provided useful soft tissue guidance in all cases and was never misleading. CONCLUSIONS XFM provides operators with meaningful three-dimensional soft tissue data and reduces fluoroscopy time in select congenital heart disease interventions.
Collapse
Affiliation(s)
- Elena K. Grant
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Joshua P. Kanter
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Laura J. Olivieri
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Russell R. Cross
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Adrienne Campbell-Washburn
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Anthony Z. Faranesh
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Ileen Cronin
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Karin S. Hamann
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Michael L. O’Byrne
- Divison of Cardiology, The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania
| | - Michael C. Slack
- Children’s Heart Program, University of Maryland Children’s Heart Program, Baltimore, Maryland
| | - Robert J. Lederman
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Kanishka Ratnayaka
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
- Department of Cardiology, Rady Children’s Hospital, San Diego, California
| |
Collapse
|
3
|
A new approach of three-dimensional guidance in paediatric cath lab: segmented and tessellated heart models for cardiovascular interventions in CHD. Cardiol Young 2018; 28:661-667. [PMID: 29345604 DOI: 10.1017/s1047951117002840] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Optimal imaging is essential for catheter-based interventions in CHD. The three-dimensional models in volume-rendering technique currently in use are not standardised. This paper investigates the feasibility and impact of novel three-dimensional guidance with segmented and tessellated three-dimensional heart models in catheterisation of CHD. In addition, a nearly radiation-free two- to three-dimensional registration and a biplane overlay were used.Methods and resultsWe analysed 60 consecutive cases in which segmented tessellated three-dimensional heart models were merged with live fluoroscopy images and aligned using the tracheal bifurcation as a fiducial mark. The models were generated from previous MRI or CT by dedicated medical software. We chose the stereo-lithography format, as this promises advantage over volume-rendering-technique models regarding visualisation. Prospects, potential benefits, and accuracy of the two- to three-dimensional registration were rated separately by two paediatric interventionalists on a five-point Likert scale. Fluoroscopy time, radiation dose, and contrast dye consumption were evaluated. Over a 10-month study period, two- to three-dimensional image fusion was applied to 60 out of 354 cases. Of the 60 catheterisations, 73.3% were performed in the context of interventions. The accuracy of two- to three-dimensional registration was sufficient in all cases. Three-dimensional guidance was rated superior to conventional biplane imaging in all 60 cases. We registered significantly smaller amounts of used contrast dye (p<0.01), lower levels of radiation dose (p<0.02), and less fluoroscopy time (p<0.01) during interventions concerning the aortic arch compared with a control group. CONCLUSIONS Two- to three-dimensional image fusion can be applied successfully in most catheter-based interventions of CHD. Meshes in stereo-lithography format are accurate and base for standardised and reproducible three-dimensional models.
Collapse
|
4
|
Zampi JD, Whiteside W. Innovative interventional catheterization techniques for congenital heart disease. Transl Pediatr 2018; 7:104-119. [PMID: 29770292 PMCID: PMC5938250 DOI: 10.21037/tp.2017.12.02] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2017] [Accepted: 12/01/2017] [Indexed: 11/06/2022] Open
Abstract
Since 1929, when the first cardiac catheterization was safely performed in a human by Dr. Werner Forssmann (on himself), there has been a rapid progression of cardiac catheterization techniques and technologies. Today, these advances allow us to treat a wide variety of patients with congenital heart disease using minimally invasive techniques; from fetus to infants to adults, and from simple to complex congenital cardiac lesions. In this article, we will explore some of the exciting advances in cardiac catheterization for the treatment of congenital heart disease, including transcatheter valve implantation, hybrid procedures, biodegradable technologies, and magnetic resonance imaging (MRI)-guided catheterization. Additionally, we will discuss innovations in imaging in the catheterization laboratory, including 3D rotational angiography (3DRA), fusion imaging, and 3D printing, which help to make innovative interventional approaches possible.
Collapse
Affiliation(s)
- Jeffrey D Zampi
- University of Michigan Congenital Heart Center, C.S. Mott Children's Hospital, Ann Arbor, MI, USA
| | - Wendy Whiteside
- University of Michigan Congenital Heart Center, C.S. Mott Children's Hospital, Ann Arbor, MI, USA
| |
Collapse
|
5
|
Fischer P, Faranesh A, Pohl T, Maier A, Rogers T, Ratnayaka K, Lederman R, Hornegger J. An MR-Based Model for Cardio-Respiratory Motion Compensation of Overlays in X-Ray Fluoroscopy. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:47-60. [PMID: 28692969 PMCID: PMC5750091 DOI: 10.1109/tmi.2017.2723545] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In X-ray fluoroscopy, static overlays are used to visualize soft tissue. We propose a system for cardiac and respiratory motion compensation of these overlays. It consists of a 3-D motion model created from real-time magnetic resonance (MR) imaging. Multiple sagittal slices are acquired and retrospectively stacked to consistent 3-D volumes. Slice stacking considers cardiac information derived from the ECG and respiratory information extracted from the images. Additionally, temporal smoothness of the stacking is enhanced. Motion is estimated from the MR volumes using deformable 3-D/3-D registration. The motion model itself is a linear direct correspondence model using the same surrogate signals as slice stacking. In X-ray fluoroscopy, only the surrogate signals need to be extracted to apply the motion model and animate the overlay in real time. For evaluation, points are manually annotated in oblique MR slices and in contrast-enhanced X-ray images. The 2-D Euclidean distance of these points is reduced from 3.85 to 2.75 mm in MR and from 3.0 to 1.8 mm in X-ray compared with the static baseline. Furthermore, the motion-compensated overlays are shown qualitatively as images and videos.
Collapse
|
6
|
Ciske BR, Speidel MA, Raval AN. Improving the cardiac cath-lab interventional imaging eco-system. Transl Pediatr 2018; 7:1-4. [PMID: 29441275 PMCID: PMC5803015 DOI: 10.21037/tp.2017.09.03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Affiliation(s)
- Benjamin R Ciske
- Department of Medicine, University of Wisconsin, Madison, WI, USA
| | - Michael A Speidel
- Department of Medicine, University of Wisconsin, Madison, WI, USA.,Department of Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Amish N Raval
- Department of Medicine, University of Wisconsin, Madison, WI, USA
| |
Collapse
|
7
|
|
8
|
Fischer P, Pohl T, Faranesh A, Maier A, Hornegger J. Unsupervised Learning for Robust Respiratory Signal Estimation From X-Ray Fluoroscopy. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:865-877. [PMID: 27654320 PMCID: PMC5489115 DOI: 10.1109/tmi.2016.2609888] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Respiratory signals are required for image gating and motion compensation in minimally invasive interventions. In X-ray fluoroscopy, extraction of a respiratory signal can be challenging due to characteristics of interventional imaging, in particular injection of contrast agent and automatic exposure control. We present a novel method for respiratory signal extraction based on dimensionality reduction that can tolerate these events. Images are divided into patches of multiple sizes. Low-dimensional embeddings are generated for each patch using illumination-invariant kernel PCA. Patches with respiratory information are selected automatically by agglomerative clustering. The signals from this respiratory cluster are combined robustly to a single respiratory signal. In the experiments, we evaluate our method on a variety of scenarios. If the diaphragm is visible, we track its superior-inferior motion as ground truth. Our method has a correlation coefficient of more than 91% with the ground truth irrespective of whether or not contrast agent injection or automatic exposure control occur. Additionally, we show that very similar signals are estimated from biplane sequences and from sequences without visible diaphragm. Since all these cases are handled automatically, the method is robust enough to be considered for use in a clinical setting.
Collapse
|
9
|
McGuirt D, Mazal J, Rogers T, Faranesh AZ, Schenke W, Stine A, Grant L, Lederman RJ. X-ray Fused With Magnetic Resonance Imaging to Guide Endomyocardial Biopsy of a Right Ventricular Mass. Radiol Technol 2016; 87:622-626. [PMID: 27390230 PMCID: PMC5027072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2015] [Accepted: 02/04/2016] [Indexed: 06/06/2023]
Abstract
BACKGROUND A patient with a history of cancer in remission and congestive heart failure with no acute symptoms presented for a follow-up echocardiogram. The scan revealed a new echodense mass filling his right ventricular apex. An endomyocardial biopsy guided by x-ray fused with magnetic resonance (MR) imaging (XFM) was performed. This case report outlines the steps of XFM image preparation involving MR image acquisition, processing, and coregistration with x-ray fluoroscopy. DISCUSSION In cases of focal pathology or cardiac masses, endomyocardial biopsy can be challenging because x-ray fluoroscopy guidance offers limited visualization of soft-tissue structures. XFM overcomes this issue by overlaying high-resolution MR images onto x-ray fluoroscopy images. CONCLUSION This case report illustrates the clinical use of XFM for endomyocardial biopsy of an apical right ventricular mass and provides a practical, step-by-step description of MR image acquisition, processing, and coregistration with fluoroscopy, as performed by the MR technologist.
Collapse
|
10
|
Schmidt EJ. Magnetic Resonance Imaging-Guided Cardiac Interventions. Magn Reson Imaging Clin N Am 2015; 23:563-77. [PMID: 26499275 DOI: 10.1016/j.mric.2015.05.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Performing intraoperative cardiovascular procedures inside an MR imaging scanner can potentially provide substantial advantage in clinical outcomes by reducing the risk and increasing the success rate relative to the way such procedures are performed today, in which the primary surgical guidance is provided by X-ray fluoroscopy, by electromagnetically tracked intraoperative devices, and by ultrasound. Both noninvasive and invasive cardiologists are becoming increasingly familiar with the capabilities of MR imaging for providing anatomic and physiologic information that is unequaled by other modalities. As a result, researchers began performing animal (preclinical) interventions in the cardiovascular system in the early 1990s.
Collapse
Affiliation(s)
- Ehud J Schmidt
- Radiology Department, Brigham and Women's Hospital, 221 Longwood Avenue, Room BRB 34C, Boston, MA 02115, USA.
| |
Collapse
|
11
|
Fagan TE, Truong UT, Jone PN, Bracken J, Quaife R, Hazeem AAA, Salcedo EE, Fonseca BM. Multimodality 3-dimensional image integration for congenital cardiac catheterization. Methodist Debakey Cardiovasc J 2015; 10:68-76. [PMID: 25114757 DOI: 10.14797/mdcj-10-2-68] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
Cardiac catheterization procedures for patients with congenital and structural heart disease are becoming more complex. New imaging strategies involving integration of 3-dimensional images from rotational angiography, magnetic resonance imaging (MRI), computerized tomography (CT), and transesophageal echocardiography (TEE) are employed to facilitate these procedures. We discuss the current use of these new 3D imaging technologies and their advantages and challenges when used to guide complex diagnostic and interventional catheterization procedures in patients with congenital heart disease.
Collapse
Affiliation(s)
| | | | | | - John Bracken
- University of Colorado, Aurora, Colorado ; Philips Research North America, Briarcliff Manor, New York
| | | | | | | | | |
Collapse
|
12
|
Panayiotou M, Rhode KS, King AP, Ma Y, Cooklin M, O'Neill M, Gill J, Rinaldi CA, Housden RJ. Image-based view-angle independent cardiorespiratory motion gating and coronary sinus catheter tracking for x-ray-guided cardiac electrophysiology procedures. Phys Med Biol 2015; 60:8087-108. [PMID: 26425860 DOI: 10.1088/0031-9155/60/20/8087] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Determination of the cardiorespiratory phase of the heart has numerous applications during cardiac imaging. In this article we propose a novel view-angle independent near-real time cardiorespiratory motion gating and coronary sinus (CS) catheter tracking technique for x-ray fluoroscopy images that are used to guide cardiac electrophysiology procedures. The method is based on learning CS catheter motion using principal component analysis and then applying the derived motion model to unseen images taken at arbitrary projections, using the epipolar constraint. This method is also able to track the CS catheter throughout the x-ray images in any arbitrary subsequent view. We also demonstrate the clinical application of our model on rotational angiography sequences. We validated our technique in normal and very low dose phantom and clinical datasets. For the normal dose clinical images we established average systole, end-expiration and end-inspiration gating success rates of 100%, 85.7%, and 92.3%, respectively. For very low dose applications, the technique was able to track the CS catheter with median errors not exceeding 1 mm for all tracked electrodes. Average gating success rates of 80.3%, 71.4%, and 69.2% were established for the application of the technique on clinical datasets, even with a dose reduction of more than 10 times. In rotational sequences at normal dose, CS tracking median errors were within 1.2 mm for all electrodes, and the gating success rate was 100%, for view angles from RAO 90° to LAO 90°. This view-angle independent technique can extract clinically useful cardiorespiratory motion information using x-ray doses significantly lower than those currently used in clinical practice.
Collapse
Affiliation(s)
- Maria Panayiotou
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London SE1 7EH, UK
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Schmidt EJ, Tse ZTH, Reichlin TR, Michaud GF, Watkins RD, Butts-Pauly K, Kwong RY, Stevenson W, Schweitzer J, Byrd I, Dumoulin CL. Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models. Magn Reson Med 2015; 71:1197-209. [PMID: 23580479 DOI: 10.1002/mrm.24742] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
PURPOSE Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists navigation, mapping, and radiofrequency ablation. Multimodality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound electrophysiological suite, increasing the likelihood of patient-motion and image misregistration. An MRI-compatible VDT system may increase efficiency, as there is currently no single method to track devices both inside and outside the MRI scanner. METHODS An MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radiofrequency unblanking pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT electro-anatomic mapping interventions were performed, navigating inside and thereafter outside the MRI. RESULTS Three-catheter VDT interventions were performed at >12 frames per second both inside and outside the MRI scanner with <3 mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition time >32 ms sequences with <0.5 mm errors, and <5% MRI signal-to-noise ratio (SNR) loss. At shorter repetition times, only intracardiac electrocardiogram was reliable. Radiofrequency heating was <1.5°C. CONCLUSION An MRI-compatible VDT system is feasible.
Collapse
Affiliation(s)
- Ehud J Schmidt
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Whiteside W, Christensen J, Zampi JD. Three-dimensional magnetic resonance imaging overlay to assist with percutaneous transhepatic access at the time of cardiac catheterization. Ann Pediatr Cardiol 2015; 8:150-2. [PMID: 26085770 PMCID: PMC4453187 DOI: 10.4103/0974-2069.154146] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Multimodality image overlay is increasingly used for complex interventional procedures in the cardiac catheterization lab. We report a case in which three-dimensional magnetic resonance imaging (3D MRI) overlay onto live fluoroscopic imaging was utilized to safely obtain transhepatic access in a 12-year-old patient with prune belly syndrome, complex and distorted abdominal anatomy, and a vascular mass within the liver.
Collapse
Affiliation(s)
- Wendy Whiteside
- The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, United States
| | - Jason Christensen
- Division of Pediatric Cardiology, Monroe Carell Jr. Children's Hospital at Vanderbilt, Nashville, Tennessee, United States
| | - Jeffrey D Zampi
- Department of Pediatrics, Division of Pediatric Cardiology, University of Michigan, Ann Arbor, Michigan, United States
| |
Collapse
|
15
|
Pushparajah K, Tzifa A, Razavi R. Cardiac MRI catheterization: a 10-year single institution experience and review. Interv Cardiol 2014. [DOI: 10.2217/ica.14.28] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
16
|
Abu Hazeem AA, Dori Y, Whitehead KK, Harris MA, Fogel MA, Gillespie MJ, Rome JJ, Glatz AC. X-ray magnetic resonance fusion modality may reduce radiation exposure and contrast dose in diagnostic cardiac catheterization of congenital heart disease. Catheter Cardiovasc Interv 2014; 84:795-800. [PMID: 24619541 DOI: 10.1002/ccd.25473] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Revised: 02/25/2014] [Accepted: 03/01/2014] [Indexed: 11/05/2022]
Abstract
BACKGROUND Radiation exposure in the pediatric population may increase the risk of future malignancy. Children with congenital heart disease who often undergo repeated catheterizations are at risk. One possible strategy to reduce radiation is to use X-ray Magnetic Resonance Fusion (XMRF) to facilitate cardiac catheterization. METHODS Catheterization data of patients who underwent diagnostic XMRF procedures between January 1, 2009 and February 1, 2012 were reviewed. Cases were matched 1:1 to contemporary controls who did not undergo XMRF based on weight and diagnosis and were compared in radiation exposure, contrast dose, and procedural and anesthesia times. RESULTS Forty-four matched pairs were included. Baseline demographics were similar in both groups. Patients in the XMRF group had lower indices of radiation exposure measured by fluoroscopy time (14 vs. 16.4 vs. P = 0.047), dose-area product from fluoroscopy (513.2 vs. 589.1 µGy·m(2) , P = 0.042), total dose-area product (625.8 vs. 995.2 µGy·m(2) , P = 0.027), and total air kerma dose (94.5 vs. 153.8 mGy, P = 0.017). There was also a significant reduction in contrast dose (2 vs. 3.3 cc/kg, P <0.001). Procedural time tended to be shorter in the XMRF group but anesthesia time was significantly longer. CONCLUSION Select diagnostic cardiac catheterization cases that utilized XMRF used less radiation and contrast than similar cases where XMRF was not used. Future work is needed to determine whether similar benefits can be extended to other types of diagnostic and complex interventional procedures.
Collapse
Affiliation(s)
- Anas A Abu Hazeem
- Division of Cardiology, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Faranesh AZ, Kellman P, Ratnayaka K, Lederman RJ. Integration of cardiac and respiratory motion into MRI roadmaps fused with x-ray. Med Phys 2013; 40:032302. [PMID: 23464334 DOI: 10.1118/1.4789919] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
PURPOSE Volumetric roadmaps overlaid on live x-ray fluoroscopy may be used to enhance image guidance during interventional procedures. These roadmaps are often static and do not reflect cardiac or respiratory motion. In this work, the authors present a method for integrating cardiac and respiratory motion into magnetic resonance imaging (MRI)-derived roadmaps to fuse with live x-ray fluoroscopy images, and this method was tested in large animals. METHODS Real-time MR images were used to capture cardiac and respiratory motion. Nonrigid registration was used to calculate motion fields to deform a reference end-expiration, end-diastolic image to different cardiac and respiratory phases. These motion fields were fit to separate affine motion models for the aorta and proximal right coronary artery. Under x-ray fluoroscopy, an image-based navigator and ECG signal were used as inputs to deform the roadmap for live overlay. The in vivo accuracy of motion correction was measured in four swine as the ventilator tidal volume was varied. RESULTS Motion correction reduced the root-mean-square error between the roadmaps and manually drawn centerlines, even under high tidal volume conditions. For the aorta, the error was reduced from 2.4 ± 1.5 mm to 2.2 ± 1.5 mm (p < 0.05). For the proximal right coronary artery, the error was reduced from 8.8 ± 16.2 mm to 4.3 ± 5.2 mm (p < 0.001). Using real-time MRI and an affine motion model it is feasible to incorporate physiological cardiac and respiratory motion into MRI-derived roadmaps to provide enhanced image guidance for interventional procedures. CONCLUSIONS A method has been presented for creating dynamic 3D roadmaps that incorporate cardiac and respiratory motion. These roadmaps can be overlaid on live X-ray fluoroscopy to enhance image guidance for cardiac interventions.
Collapse
Affiliation(s)
- Anthony Z Faranesh
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892-1538, USA.
| | | | | | | |
Collapse
|
18
|
Faranesh AZ, Lederman RJ. Roadmaps show the way: coregistration to enhance structural heart interventions. Catheter Cardiovasc Interv 2013; 82:443-4. [PMID: 24038978 DOI: 10.1002/ccd.25115] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2013] [Accepted: 06/27/2013] [Indexed: 11/10/2022]
Affiliation(s)
- Anthony Z Faranesh
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | | |
Collapse
|
19
|
Glöckler M, Halbfaβ J, Koch A, Achenbach S, Dittrich S. Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease-A single-center, retrospective analysis of 78 cases. Catheter Cardiovasc Interv 2013; 82:436-42. [DOI: 10.1002/ccd.24646] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2012] [Accepted: 08/27/2012] [Indexed: 12/20/2022]
Affiliation(s)
- Martin Glöckler
- Department of Pediatric Cardiology; University Hospital Erlangen; Erlangen; Germany
| | - Julia Halbfaβ
- Department of Pediatric Cardiology; University Hospital Erlangen; Erlangen; Germany
| | - Andreas Koch
- Department of Pediatric Cardiology; University Hospital Erlangen; Erlangen; Germany
| | - Stephan Achenbach
- Department of Cardiology; University Hospital Giessen; Giessen; Germany
| | - Sven Dittrich
- Department of Pediatric Cardiology; University Hospital Erlangen; Erlangen; Germany
| |
Collapse
|
20
|
Barbash IM, Cecchini S, Faranesh AZ, Virag T, Li L, Yang Y, Hoyt RF, Kornegay JN, Bogan JR, Garcia L, Lederman RJ, Kotin RM. MRI roadmap-guided transendocardial delivery of exon-skipping recombinant adeno-associated virus restores dystrophin expression in a canine model of Duchenne muscular dystrophy. Gene Ther 2013; 20:274-82. [PMID: 22551778 PMCID: PMC3424392 DOI: 10.1038/gt.2012.38] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Accepted: 03/29/2012] [Indexed: 01/16/2023]
Abstract
Duchenne muscular dystrophy (DMD) cardiomyopathy patients currently have no therapeutic options. We evaluated catheter-based transendocardial delivery of a recombinant adeno-associated virus (rAAV) expressing a small nuclear U7 RNA (U7smOPT) complementary to specific cis-acting splicing signals. Eliminating specific exons restores the open reading frame resulting in translation of truncated dystrophin protein. To test this approach in a clinically relevant DMD model, golden retriever muscular dystrophy (GRMD) dogs received serotype 6 rAAV-U7smOPT via the intracoronary or transendocardial route. Transendocardial injections were administered with an injection-tipped catheter and fluoroscopic guidance using X-ray fused with magnetic resonance imaging (XFM) roadmaps. Three months after treatment, tissues were analyzed for DNA, RNA, dystrophin protein, and histology. Whereas intracoronary delivery did not result in effective transduction, transendocardial injections, XFM guidance, enabled 30±10 non-overlapping injections per animal. Vector DNA was detectable in all samples tested and ranged from <1 to >3000 vector genome copies per cell. RNA analysis, western blot analysis, and immunohistology demonstrated extensive expression of skipped RNA and dystrophin protein in the treated myocardium. Left ventricular function remained unchanged over a 3-month follow-up. These results demonstrated that effective transendocardial delivery of rAAV-U7smOPT was achieved using XFM. This approach restores an open reading frame for dystrophin in affected dogs and has potential clinical utility.
Collapse
Affiliation(s)
- I M Barbash
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Kagadis GC, Katsanos K, Karnabatidis D, Loudos G, Nikiforidis GC, Hendee WR. Emerging technologies for image guidance and device navigation in interventional radiology. Med Phys 2012; 39:5768-81. [PMID: 22957641 DOI: 10.1118/1.4747343] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Recent developments in image-guidance and device navigation, along with emerging robotic technologies, are rapidly transforming the landscape of interventional radiology (IR). Future state-of-the-art IR procedures may include real-time three-dimensional imaging that is capable of visualizing the target organ, interventional tools, and surrounding anatomy with high spatial and temporal resolution. Remote device actuation is becoming a reality with the introduction of novel magnetic-field enabled instruments and remote robotic steering systems. Robots offer several degrees of freedom and unprecedented accuracy, stability, and dexterity during device navigation, propulsion, and actuation. Optimization of tracking and navigation of interventional tools inside the human body will be critical in converting IR suites into the minimally invasive operating theaters of the future with increased safety and unsurpassed therapeutic efficacy. In the not too distant future, individual image guidance modalities and device tracking methods could merge into autonomous, multimodality, multiparametric platforms that offer real-time data of anatomy, morphology, function, and metabolism along with on-the-fly computational modeling and remote robotic actuation. The authors provide a concise overview of the latest developments in image guidance and device navigation, while critically envisioning what the future might hold for 2020 IR procedures.
Collapse
Affiliation(s)
- George C Kagadis
- Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece.
| | | | | | | | | | | |
Collapse
|
22
|
Klein AJ, Tomkowiak MT, Vigen KK, Hacker TA, Speidel MA, Vanlysel MS, Shah N, Raval AN. Multimodality image fusion to guide peripheral artery chronic total arterial occlusion recanalization in a swine carotid artery occlusion model: unblinding the interventionalist. Catheter Cardiovasc Interv 2012; 80:1090-8. [PMID: 23097307 DOI: 10.1002/ccd.24391] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2011] [Revised: 02/15/2012] [Accepted: 02/20/2012] [Indexed: 11/09/2022]
Abstract
OBJECTIVES To demonstrate the feasibility of magnetic resonance imaging (MRI) to X-ray fluoroscopy (XRF) image fusion to guide peripheral artery chronic total occlusion (CTO) recanalization. BACKGROUND Endovascular peripheral artery CTO revascularization is minimally invasive, but challenging, because the occlusion is poorly visualized under XRF. Devices may steer out of the artery, which can lead to severe perforation. Merging preacquired MRI of the CTO to the live XRF display may permit upfront use of aggressive devices and improve procedural outcomes. METHODS Swine carotid artery CTOs were created using a balloon injury model. Up to 8 weeks later, MRI of the carotid arteries was acquired and segmented to create three-dimensional surface models, which were then registered onto live XRF. CTO recanalization was performed using incrementally aggressive CTO devices (group A) or an upfront aggressive directed laser approach (group B). Procedural success was defined as luminal or subintimal device position without severe perforation. RESULTS In this swine model, MRI to XRF fusion guidance resulted in a procedural success of 57% in group A and 100% in group B, which compared favorably to 33% using XRF alone. Fluoroscopy time was significantly less for group B (8.5 ± 2.6 min) compared to group A (48.7 ± 23.9 min), P < 0.01. Contrast dose used was similar between groups A and B. CONCLUSIONS MRI to XRF fusion-guided peripheral artery CTO recanalization is feasible. Multimodality image fusion may permit upfront use of aggressive CTO devices with improved procedural outcomes compared to XRF-guided procedures.
Collapse
Affiliation(s)
- Andrew J Klein
- Department of Medicine, Division of Cardiology, John Cochran Veterans Affairs Medical Center, St. Louis University School of Medicine, St. Louis, Missouri, USA
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Ratnayaka K, Saikus CE, Faranesh AZ, Bell JA, Barbash IM, Kocaturk O, Reyes CA, Sonmez M, Schenke WH, Wright VJ, Hansen MS, Slack MC, Lederman RJ. Closed-chest transthoracic magnetic resonance imaging-guided ventricular septal defect closure in swine. JACC Cardiovasc Interv 2011; 4:1326-34. [PMID: 22192373 PMCID: PMC3670769 DOI: 10.1016/j.jcin.2011.09.012] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2011] [Accepted: 09/03/2011] [Indexed: 11/29/2022]
Abstract
OBJECTIVES The aim of this study was to close ventricular septal defects (VSDs) directly through the chest wall using magnetic resonance imaging (MRI) guidance, without cardiopulmonary bypass, sternotomy, or radiation exposure. BACKGROUND Surgical, percutaneous, and hybrid management of VSD each have limitations and known morbidity. METHODS Percutaneous muscular VSDs were created in 10 naive Yorkshire swine using a transjugular laser catheter. Under real-time MRI guidance, a direct transthoracic vascular access sheath was introduced through the chest into the heart along a trajectory suitable for VSD access and closure. Through this transthoracic sheath, muscular VSDs were occluded using a commercial nitinol device. Finally, the right ventricular free wall was closed using a commercial collagen plug intended for arterial closure. RESULTS Anterior, posterior, and mid-muscular VSDs (6.8 ± 1.8 mm) were created. VSDs were closed successfully in all animals. The transthoracic access sheath was displaced in 2, both fatal. Thereafter, we tested an intracameral retention sheath to prevent this complication. Right ventricular access ports were closed successfully in all, and after as many as 30 days, healed successfully. CONCLUSIONS Real-time MRI guidance allowed closed-chest transthoracic perventricular muscular VSD closure in a clinically meaningful animal model. Once applied to patients, this approach may avoid traditional surgical, percutaneous, or open-chest transcatheter ("hybrid") risks.
Collapse
Affiliation(s)
- Kanishka Ratnayaka
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
- Cardiology Division, Children’s National Medical Center, Washington, DC
| | - Christina E. Saikus
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Anthony Z. Faranesh
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Jamie A. Bell
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Israel M. Barbash
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Ozgur Kocaturk
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | | | - Merdim Sonmez
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - William H. Schenke
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Victor J. Wright
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Michael S. Hansen
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Michael C. Slack
- Cardiology Division, Children’s National Medical Center, Washington, DC
| | - Robert J. Lederman
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| |
Collapse
|
24
|
Ecabert O, Peters J, Walker MJ, Ivanc T, Lorenz C, von Berg J, Lessick J, Vembar M, Weese J. Segmentation of the heart and great vessels in CT images using a model-based adaptation framework. Med Image Anal 2011; 15:863-76. [PMID: 21737337 DOI: 10.1016/j.media.2011.06.004] [Citation(s) in RCA: 72] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2010] [Revised: 06/04/2011] [Accepted: 06/07/2011] [Indexed: 01/04/2023]
Abstract
Recently, model-based methods for the automatic segmentation of the heart chambers have been proposed. An important application of these methods is the characterization of the heart function. Heart models are, however, increasingly used for interventional guidance making it necessary to also extract the attached great vessels. It is, for instance, important to extract the left atrium and the proximal part of the pulmonary veins to support guidance of ablation procedures for atrial fibrillation treatment. For cardiac resynchronization therapy, a heart model including the coronary sinus is needed. We present a heart model comprising the four heart chambers and the attached great vessels. By assigning individual linear transformations to the heart chambers and to short tubular segments building the great vessels, variable sizes of the heart chambers and bending of the vessels can be described in a consistent way. A configurable algorithmic framework that we call adaptation engine matches the heart model automatically to cardiac CT angiography images in a multi-stage process. First, the heart is detected using a Generalized Hough Transformation. Subsequently, the heart chambers are adapted. This stage uses parametric as well as deformable mesh adaptation techniques. In the final stage, segments of the large vascular structures are successively activated and adapted. To optimize the computational performance, the adaptation engine can vary the mesh resolution and freeze already adapted mesh parts. The data used for validation were independent from the data used for model-building. Ground truth segmentations were generated for 37 CT data sets reconstructed at several cardiac phases from 17 patients. Segmentation errors were assessed for anatomical sub-structures resulting in a mean surface-to-surface error ranging 0.50-0.82mm for the heart chambers and 0.60-1.32mm for the parts of the great vessels visible in the images.
Collapse
Affiliation(s)
- Olivier Ecabert
- Philips Research Europe - Aachen, X-ray Imaging, 52062 Aachen, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Dori Y, Sarmiento M, Glatz AC, Gillespie MJ, Jones VM, Harris MA, Whitehead KK, Fogel MA, Rome JJ. X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization. Circ Cardiovasc Imaging 2011; 4:415-24. [PMID: 21536785 DOI: 10.1161/circimaging.111.963868] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND X-ray magnetic resonance fusion (XMRF) allows for use of 3D data during cardiac catheterization. However, to date, technical requirements have limited the use of this modality in clinical practice. We report on a new internal-marker XMRF method that we have developed and describe how we used XMRF during cardiac catheterization in congenital heart disease. METHODS AND RESULTS XMRF was performed in a phantom and in 23 patients presenting for cardiac catheterization who also needed cardiac MRI for clinical reasons. The registration process was performed in < 5 minutes per patient, with minimal radiation (0.004 to 0.024 mSv) and without contrast. Registration error was calculated in a phantom and in 8 patients using the maximum distance between angiographic and 3D model boundaries. In the phantom, the measured error in the anteroposterior projection had a mean of 1.15 mm (standard deviation, 0.73). The measured error in patients had a median of 2.15 mm (interquartile range, 1.65 to 2.56 mm). Internal markers included bones, airway, image artifact, calcifications, and the heart and vessel borders. The MRI data were used for road mapping in 17 of 23 (74%) cases and camera angle selection in 11 of 23 (48%) cases. CONCLUSIONS Internal marker-based registration can be performed quickly, with minimal radiation, without the need for contrast, and with clinically acceptable accuracy using commercially available software. We have also demonstrated several potential uses for XMRF in routine clinical practice. This modality has the potential to reduce radiation exposure and improve catheterization outcomes.
Collapse
Affiliation(s)
- Yoav Dori
- Department of Cardiology, The Children's Hospital of Philadelphia, Philadelphia, PA, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
George AK, Sonmez M, Lederman RJ, Faranesh AZ. Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures. Med Phys 2011; 38:125-41. [PMID: 21361182 DOI: 10.1118/1.3523621] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In X-ray fused with MRI, previously gathered roadmap MRI volume images are overlaid on live X-ray fluoroscopy images to help guide the clinician during an interventional procedure. The incorporation of MRI data allows for the visualization of soft tissue that is poorly visualized under X-ray. The widespread clinical use of this technique will require fully automating as many components as possible. While previous use of this method has required time-consuming manual intervention to register the two modalities, in this article, the authors present a fully automatic rigid-body registration method. METHODS External fiducial markers that are visible under these two complimentary imaging modalities were used to register the X-ray images with the roadmap MR images. The method has three components: (a) The identification of the 3D locations of the markers from a full 3D MR volume, (b) the identification of the 3D locations of the markers from a small number of 2D X-ray fluoroscopy images, and (c) finding the rigid-body transformation that registers the two point sets in the two modalities. For part (a), the localization of the markers from MR data, the MR volume image was thresholded, connected voxels were segmented and labeled, and the centroids of the connected components were computed. For part (b), the X-ray projection images, produced by an image intensifier, were first corrected for distortions. Binary mask images of the markers were created from the distortion-corrected X-ray projection images by applying edge detection, pattern recognition, and image morphological operations. The markers were localized in the X-ray frame using an iterative backprojection-based method which segments voxels in the volume of interest, discards false positives based on the previously computed edge-detected projections, and calculates the locations of the true markers as the centroids of the clusters of voxels that remain. For part (c), a variant of the iterative closest point method was used to find correspondences between and register the two sets of points computed from MR and X-ray data. This knowledge of the correspondence between the two point sets was used to refine, first, the X-ray marker localization and then the total rigid-body registration between modalities. The rigid-body registration was used to overlay the roadmap MR image onto the X-ray fluoroscopy projections. RESULTS In 35 separate experiments, the markers were correctly registered to each other in 100% of the cases. When half the number of X-ray projections was used (10 X-ray projections instead of 20), the markers were correctly registered in all 35 experiments. The method was also successful in all 35 experiments when the number of markers was (retrospectively) halved (from 16 to 8). The target registration error was computed in a phantom experiment to be less than 2.4 mm. In two in vivo experiments, targets (interventional devices with pointlike metallic structures) inside the heart were successfully registered between the two modalities. CONCLUSIONS The method presented can be used to automatically register a roadmap MR image to X-ray fluoroscopy using fiducial markers and as few as ten X-ray projections.
Collapse
Affiliation(s)
- Ashvin K George
- Translational Medicine Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892-1538, USA.
| | | | | | | |
Collapse
|
27
|
Glatz AC, Zhu X, Gillespie MJ, Hanna BD, Rome JJ. Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease. JACC Cardiovasc Imaging 2011; 3:1149-57. [PMID: 21071003 DOI: 10.1016/j.jcmg.2010.09.011] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2010] [Revised: 08/26/2010] [Accepted: 09/16/2010] [Indexed: 11/16/2022]
Abstract
OBJECTIVES This study sought to retrospectively evaluate our initial experience using angiographic computed tomography (ACT) in a pediatric cardiac catheterization laboratory. BACKGROUND ACT provides cross-sectional CT images from a rotational angiography run using a C-arm mounted flat-panel detector in the interventional suite. A 3-dimensional (3D) angiographic image can be created from the CT volume set and used in real time during the procedure. To our knowledge, its use has never previously been described for congenital heart disease. METHODS 3D reconstructions were created and we retrospectively reviewed cases during our first year of ACT use. Images obtained were independently evaluated to determine their diagnostic utility. Radiation dose reduction protocols were defined using phantom testing and radiation dose calculation. RESULTS ACT was used during 41 cardiac catheterizations in patients at a median age of 5.1 years (range: 0.4 to 58.8 years) for evaluation of: right ventricular outflow tract (RVOT)/central pulmonary arteries (PAs) in 20; cavopulmonary connection (CPC) in 11; pulmonary veins in 5; distal PAs in 4; and other locations in 5. Four subjects had 2 anatomic areas studied by ACT. The mean contrast volume for ACT was 1.2 ± 0.4 ml/kg. Diagnostic-quality imaging was obtained in 71% of cases: 13/20 RVOT/central PAs; 9/11 CPC; 4/5 pulmonary veins; 2/4 distal PAs; and 4/5 others. In 12 cases, ACT contributed to clinical outcomes beyond standard angiography. Radiation dose reduction protocols allowed ACT to be comparable in exposure to a standard biplane cineangiogram. CONCLUSIONS Diagnostic-quality imaging can be obtained using ACT in 71% of cases without a significant increase in contrast or radiation exposure. In certain cases, ACT provides additional anatomic detail and may aid complex catheter manipulations. Future work is needed to continue to define applications of this new technology.
Collapse
Affiliation(s)
- Andrew C Glatz
- Division of Cardiology, Department of Pediatrics, Children's Hospital of Philadelphia, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania, USA.
| | | | | | | | | |
Collapse
|
28
|
Abstract
Medical imaging in interventional oncology is used differently than in diagnostic radiology and prioritizes different imaging features. Whereas diagnostic imaging prioritizes the highest-quality imaging, interventional imaging prioritizes real-time imaging with lower radiation dose in addition to high-quality imaging. In general, medical imaging plays five key roles in image-guided therapy, and interventional oncology, in particular. These roles are (a) preprocedure planning, (b) intraprocedural targeting, (c) intraprocedural monitoring, (d) intraprocedural control, and (e) postprocedure assessment. Although many of these roles are still relatively basic in interventional oncology, as research and development in medical imaging focuses on interventional needs, it is likely that the role of medical imaging in intervention will become even more integral and more widely applied. In this review, the current status of medical imaging for intervention in oncology will be described and directions for future development will be examined.
Collapse
Affiliation(s)
- Stephen B Solomon
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10021, USA.
| | | |
Collapse
|
29
|
Saybasili H, Faranesh AZ, Saikus CE, Ozturk C, Lederman RJ, Guttman MA. Interventional MRI using multiple 3D angiography roadmaps with real-time imaging. J Magn Reson Imaging 2010; 31:1015-9. [PMID: 20373448 DOI: 10.1002/jmri.22097] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
PURPOSE To enhance real-time magnetic resonance (MR)-guided catheter navigation by overlaying colorized multiphase MR angiography (MRA) and cholangiopancreatography (MRCP) roadmaps in an anatomic context. MATERIALS AND METHODS Time-resolved MRA and respiratory-gated MRCP were acquired prior to real-time imaging in a pig model. MRA and MRCP data were loaded into a custom real-time MRI reconstruction and visualization workstation where they were displayed as maximum intensity projections (MIPs) in distinct colors. The MIPs were rendered in 3D together with real-time multislice imaging data using alpha blending. Interactive rotation allowed different views of the combined data. RESULTS Fused display of the previously acquired MIP angiography data with real-time imaging added anatomical context during endovascular interventions in swine. The use of multiple MIPs rendered in different colors facilitated differentiation of vascular structures, improving visual feedback during device navigation. CONCLUSION Interventional real-time MRI may be enhanced by combining with previously acquired multiphase angiograms. Rendered as 3D MIPs together with 2D slice data, this technique provided useful anatomical context that enhanced MRI-guided interventional applications.
Collapse
Affiliation(s)
- Haris Saybasili
- Translational Medicine Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892-1061, USA.
| | | | | | | | | | | |
Collapse
|
30
|
Ratnayaka K, Raman VK, Faranesh AZ, Sonmez M, Kim JH, Gutiérrez LF, Ozturk C, McVeigh ER, Slack MC, Lederman RJ. Antegrade percutaneous closure of membranous ventricular septal defect using X-ray fused with magnetic resonance imaging. JACC Cardiovasc Interv 2010; 2:224-30. [PMID: 19463430 DOI: 10.1016/j.jcin.2008.09.014] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2008] [Accepted: 09/15/2008] [Indexed: 11/17/2022]
Abstract
OBJECTIVES We hypothesized that X-ray fused with magnetic resonance imaging (XFM) roadmaps might permit direct antegrade crossing and delivery of a ventricular septal defect (VSD) closure device and thereby reduce procedure time and radiation exposure. BACKGROUND Percutaneous device closure of membranous VSD is cumbersome and time-consuming. The procedure requires crossing the defect retrograde, snaring and exteriorizing a guidewire to form an arteriovenous loop, then delivering antegrade a sheath and closure device. METHODS Magnetic resonance imaging roadmaps of cardiac structures were obtained from miniature swine with spontaneous VSD and registered with live X-ray using external fiducial markers. We compared antegrade XFM-guided VSD crossing with conventional retrograde X-ray-guided crossing for repair. RESULTS Antegrade XFM crossing was successful in all animals. Compared with retrograde X-ray, antegrade XFM was associated with shorter time to crossing (167 +/- 103 s vs. 284 +/- 61 s; p = 0.025), shorter time to sheath delivery (71 +/- 32 s vs. 366 +/- 145 s; p = 0.001), shorter fluoroscopy time (158 +/- 95 s vs. 390 +/- 137 s; p = 0.003), and reduced radiation dose-area product (2,394 +/- 1,522 mG.m(2) vs. 4,865 +/- 1,759 mG.m(2); p = 0.016). CONCLUSIONS XFM facilitates antegrade access to membranous VSD from the right ventricle in swine. The simplified procedure is faster and reduces radiation exposure compared with the conventional retrograde approach.
Collapse
Affiliation(s)
- Kanishka Ratnayaka
- Translational Medicine Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892-1538, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Kapadia SR, Schoenhagen P, Stewart W, Tuzcu EM. Imaging for Transcatheter Valve Procedures. Curr Probl Cardiol 2010; 35:228-76. [DOI: 10.1016/j.cpcardiol.2010.01.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
32
|
Ratnayaka K, Lederman RJ. Interventional cardiovascular MR—The next stage in pediatric cardiology. PROGRESS IN PEDIATRIC CARDIOLOGY 2010. [DOI: 10.1016/j.ppedcard.2009.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
33
|
Saikus CE, Lederman RJ. Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions. JACC Cardiovasc Imaging 2009; 2:1321-31. [PMID: 19909937 PMCID: PMC2843404 DOI: 10.1016/j.jcmg.2009.09.002] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2009] [Revised: 09/10/2009] [Accepted: 09/11/2009] [Indexed: 01/12/2023]
Abstract
Cardiovascular magnetic resonance (CMR) combines excellent soft-tissue contrast, multiplanar views, and dynamic imaging of cardiac function without ionizing radiation exposure. Interventional cardiovascular magnetic resonance (iCMR) leverages these features to enhance conventional interventional procedures or to enable novel ones. Although still awaiting clinical deployment, this young field has tremendous potential. We survey promising clinical applications for iCMR. Next, we discuss the technologies that allow CMR-guided interventions and, finally, what still needs to be done to bring them to the clinic.
Collapse
Affiliation(s)
- Christina E Saikus
- Translational Medicine Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, NIH, Bethesda, MD 20892-1538, USA
| | | |
Collapse
|
34
|
Kim JH, Kocaturk O, Ozturk C, Faranesh AZ, Sonmez M, Sampath S, Saikus CE, Kim AH, Raman VK, Derbyshire JA, Schenke WH, Wright VJ, Berry C, McVeigh ER, Lederman RJ. Mitral cerclage annuloplasty, a novel transcatheter treatment for secondary mitral valve regurgitation: initial results in swine. J Am Coll Cardiol 2009; 54:638-51. [PMID: 19660696 DOI: 10.1016/j.jacc.2009.03.071] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2008] [Revised: 03/09/2009] [Accepted: 03/10/2009] [Indexed: 12/23/2022]
Abstract
OBJECTIVES We developed and tested a novel transcatheter circumferential annuloplasty technique to reduce mitral regurgitation in porcine ischemic cardiomyopathy. BACKGROUND Catheter-based annuloplasty for secondary mitral regurgitation exploits the proximity of the coronary sinus to the mitral annulus, but is limited by anatomic variants and coronary artery entrapment. METHODS The procedure, "cerclage annuloplasty," is guided by magnetic resonance imaging (MRI) roadmaps fused with live X-ray. A coronary sinus guidewire traverses a short segment of the basal septal myocardium to re-enter the right heart where it is exchanged for a suture. Tension is applied interactively during imaging and secured with a locking device. RESULTS We found 2 feasible suture pathways from the great cardiac vein across the interventricular septum to create cerclage. Right ventricular septal re-entry required shorter fluoroscopy times than right atrial re-entry, which entailed a longer intramyocardial traversal but did not cross the tricuspid valve. Graded tension progressively reduced septal-lateral annular diameter, but not end-systolic elastance or regional myocardial function. A simple arch-like device protected entrapped coronary arteries from compression even during supratherapeutic tension. Cerclage reduced mitral regurgitation fraction (from 22.8 +/- 12.7% to 7.2 +/- 4.4%, p = 0.04) by slice tracking velocity-encoded MRI. Flexible cerclage reduced annular size but preserved annular motion. Cerclage also displaced the posterior annulus toward the papillary muscles. Cerclage introduced reciprocal constraint to the left ventricular outflow tract and mitral annulus that enhanced leaflet coaptation. A sample of human coronary venograms and computed tomography angiograms suggested that most have suitable venous anatomy for cerclage. CONCLUSIONS Transcatheter mitral cerclage annuloplasty acutely reduces mitral regurgitation in porcine ischemic cardiomyopathy. Entrapped coronary arteries can be protected. MRI provided insight into the mechanism of cerclage action.
Collapse
Affiliation(s)
- June-Hong Kim
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, NIH, Bethesda, MD 20892-1538, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
35
|
Ratnayaka K, Faranesh AZ, Guttman MA, Kocaturk O, Saikus CE, Lederman RJ. Interventional cardiovascular magnetic resonance: still tantalizing. J Cardiovasc Magn Reson 2008; 10:62. [PMID: 19114017 PMCID: PMC2637847 DOI: 10.1186/1532-429x-10-62] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2008] [Accepted: 12/29/2008] [Indexed: 12/30/2022] Open
Abstract
The often touted advantages of MR guidance remain largely unrealized for cardiovascular interventional procedures in patients. Many procedures have been simulated in animal models. We argue these opportunities for clinical interventional MR will be met in the near future. This paper reviews technical and clinical considerations and offers advice on how to implement a clinical-grade interventional cardiovascular MR (iCMR) laboratory. We caution that this reflects our personal view of the "state of the art."
Collapse
Affiliation(s)
- Kanishka Ratnayaka
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
- Cardiology Division, Children's National Medical Center, Washington, DC, USA
| | - Anthony Z Faranesh
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Michael A Guttman
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Ozgur Kocaturk
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christina E Saikus
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert J Lederman
- Translational Medicine Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
36
|
Lederman RJ. Recanalization of chronic peripheral artery occlusions: moving forward by looking sideways. Catheter Cardiovasc Interv 2008; 71:734-5. [PMID: 18412068 DOI: 10.1002/ccd.21594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
37
|
|