1
|
Wan Y, Xie Z, Cao M, Zhang C, Feng Z, Tian B, Liu Z. Detection of urea in milk by urease-inorganic hybrid nanoflowers combined with portable colorimetric microliter tube. Mikrochim Acta 2024; 191:679. [PMID: 39422792 DOI: 10.1007/s00604-024-06734-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Accepted: 09/29/2024] [Indexed: 10/19/2024]
Abstract
A simple one-pot green synthesis method was used to prepare urease-inorganic hybrid nanoflowers (UE-HNFs), which had a high surface-to-volume ratio to improve enzyme catalytic efficiency and make urease reusable. A portable colorimetric microliter tube based on urease-inorganic hybrid nanoflowers (UE-HNFs-PCMT), as an urea colorimetric biosensor, was developed for determining urea concentration in milk. The combination of urea colorimetric biosensor and a smartphone is used for capturing the colour change of milk after reaction. There was a good linear relationship between colour intensity of the image (Δ intensity) and urea concentration (43-600 mg L-1), with a detection limit of 12.81 mg L-1. UE-HNFs-PCMT has the advantages of no need for complex equipment, easy operation, reusability, low detection cost, good portability, and environmental friendliness and can achieve urea detection in milk.
Collapse
Affiliation(s)
- Yang Wan
- State Key Laboratory of Dairy Biotechnology, Shanghai Engineering Research Center of Dairy Biotechnology, Dairy Research Institute, Bright Dairy & Food Co., Ltd., Shanghai, 200436, China
- College of Food Science, Northeast Agricultural University, Harbin, 150030, China
| | - Zhixin Xie
- College of Food Science, Northeast Agricultural University, Harbin, 150030, China
| | - Ming Cao
- College of Food Science, Northeast Agricultural University, Harbin, 150030, China
| | - Chi Zhang
- State Key Laboratory of Dairy Biotechnology, Shanghai Engineering Research Center of Dairy Biotechnology, Dairy Research Institute, Bright Dairy & Food Co., Ltd., Shanghai, 200436, China
| | - Zhibiao Feng
- Department of Chemistry, College of Arts and Sciences, Northeast Agricultural University, Harbin, 150030, China
| | - Bo Tian
- College of Food Science, Northeast Agricultural University, Harbin, 150030, China.
| | - Zhenmin Liu
- State Key Laboratory of Dairy Biotechnology, Shanghai Engineering Research Center of Dairy Biotechnology, Dairy Research Institute, Bright Dairy & Food Co., Ltd., Shanghai, 200436, China.
| |
Collapse
|
2
|
Ventura J, Llopis-Lorente A, Abdelmohsen LKEA, van Hest JCM, Martínez-Máñez R. Models of Chemical Communication for Micro/Nanoparticles. Acc Chem Res 2024; 57:815-830. [PMID: 38427324 PMCID: PMC10956390 DOI: 10.1021/acs.accounts.3c00619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 02/12/2024] [Accepted: 02/13/2024] [Indexed: 03/02/2024]
Abstract
Engineering chemical communication between micro/nanosystems (via the exchange of chemical messengers) is receiving increasing attention from the scientific community. Although a number of micro- and nanodevices (e.g., drug carriers, sensors, and artificial cells) have been developed in the last decades, engineering communication at the micro/nanoscale is a recent emergent topic. In fact, most of the studies in this research area have been published within the last 10 years. Inspired by nature─where information is exchanged by means of molecules─the development of chemical communication strategies holds wide implications as it may provide breakthroughs in many areas including nanotechnology, artificial cell research, biomedicine, biotechnology, and ICT. Published examples rely on nanotechnology and synthetic biology for the creation of micro- and nanodevices that can communicate. Communication enables the construction of new complex systems capable of performing advanced coordinated tasks that go beyond those carried out by individual entities. In addition, the possibility to communicate between synthetic and living systems can further advance our understanding of biochemical processes and provide completely new tailored therapeutic and diagnostic strategies, ways to tune cellular behavior, and new biotechnological tools. In this Account, we summarize advances by our laboratories (and others) in the engineering of chemical communication of micro- and nanoparticles. This Account is structured to provide researchers from different fields with general strategies and common ground for the rational design of future communication networks at the micro/nanoscale. First, we cover the basis of and describe enabling technologies to engineer particles with communication capabilities. Next, we rationalize general models of chemical communication. These models vary from simple linear communication (transmission of information between two points) to more complex pathways such as interactive communication and multicomponent communication (involving several entities). Using illustrative experimental designs, we demonstrate the realization of these models which involve communication not only between engineered micro/nanoparticles but also between particles and living systems. Finally, we discuss the current state of the topic and the future challenges to be addressed.
Collapse
Affiliation(s)
- Jordi Ventura
- Instituto
Interuniversitario de Investigación de Reconocimiento Molecular
y Desarrollo Tecnológico (IDM), Universitat
Politècnica de València, Universitat de València, Camino de Vera
s/n, 46022 València, Spain
| | - Antoni Llopis-Lorente
- Instituto
Interuniversitario de Investigación de Reconocimiento Molecular
y Desarrollo Tecnológico (IDM), Universitat
Politècnica de València, Universitat de València, Camino de Vera
s/n, 46022 València, Spain
- CIBER
de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, 28029 Madrid, Spain
| | - Loai K. E. A. Abdelmohsen
- Department
of Chemical Engineering & Chemistry, Department of Biomedical
Engineering, Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Het Kranenveld 14, 5600 MB Eindhoven, The Netherlands
| | - Jan C. M. van Hest
- Department
of Chemical Engineering & Chemistry, Department of Biomedical
Engineering, Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Het Kranenveld 14, 5600 MB Eindhoven, The Netherlands
| | - Ramón Martínez-Máñez
- Instituto
Interuniversitario de Investigación de Reconocimiento Molecular
y Desarrollo Tecnológico (IDM), Universitat
Politècnica de València, Universitat de València, Camino de Vera
s/n, 46022 València, Spain
- Unidad
Mixta de Investigación en Nanomedicina y Sensores, Universitat Politècnica de València,
Instituto de Investigación Sanitaria La Fe, Av Fernando Abril Martorell 106, 46026 Valencia, Spain
- Unidad
Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades
y Nanomedicina, Universitat Politècnica
de València, Centro
de Investigación Príncipe Felipe, C/Eduardo Primo Yúfera
3, 46100 Valencia, Spain
- CIBER
de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, 28029 Madrid, Spain
| |
Collapse
|
3
|
Shalileh F, Sabahi H, Golbashy M, Dadmehr M, Hosseini M. A simple smartphone-assisted paper-based colorimetric biosensor for the detection of urea adulteration in milk based on an environment-friendly pH-sensitive nanocomposite. Anal Chim Acta 2023; 1284:341935. [PMID: 37996167 DOI: 10.1016/j.aca.2023.341935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 09/29/2023] [Accepted: 10/19/2023] [Indexed: 11/25/2023]
Abstract
Urea is a common milk adulterant that falsely increases its protein content. Excessive consumption of urea is harmful to the kidney, liver, and gastrointestinal system. The conventional methods for urea detection in milk are time-consuming, costly, and require highly skilled operators. So, there is an increasing demand for the development of rapid, convenient, and cost-efficient methods for the detection of urea adulteration in milk. Herein, we report a novel colorimetric paper-based urea biosensor, consisting of a novel environment-friendly nanocomposite of halloysite nanotubes (HNT), that urease enzyme and an anthocyanin-rich extract, as a natural pH indicator are simultaneously immobilized into its internal and external surfaces. The biosensing mechanism of this biosensor is based on anthocyanin color change, which occurs due to urease-mediated hydrolysis of urea and pH increment of the environment. The colorimetric signal of this biosensor is measured through smartphone-assisted analysis of the mean RGB (Red-Green-Blue) intensity of samples and is capable of detecting urea with a detection limit of 0.2 mM, and a linear range from 0.5 to 100 mM. This biosensor has demonstrated promising results for the detection of urea in milk samples, in the presence of other milk adulterants and interferents.
Collapse
Affiliation(s)
- Farzaneh Shalileh
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Hossein Sabahi
- Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran.
| | - Mohammad Golbashy
- Department of Plant Production and Genetics, Faculty of Agriculture, Agricultural Sciences and Natural Resources, University of Khuzestan, Ahvaz, Iran
| | - Mehdi Dadmehr
- Department of Biology, Payame Noor University, Tehran, Iran
| | - Morteza Hosseini
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran; Medical Biomaterials Research Center, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
4
|
Wang Y, Zhao P, Zhang S, Zhu K, Shangguan X, Liu L, Zhang S. Application of Janus Particles in Point-of-Care Testing. BIOSENSORS 2022; 12:bios12090689. [PMID: 36140074 PMCID: PMC9496037 DOI: 10.3390/bios12090689] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 08/20/2022] [Accepted: 08/22/2022] [Indexed: 06/01/2023]
Abstract
Janus particles (JPs), named after the two-faced Roman god, are asymmetric particles with different chemical properties or polarities. JPs have been widely used in the biomedical field in recent years, including as drug carriers for targeted controlled drug release and as biosensors for biological imaging and biomarker detection, which is crucial in the early detection and treatment of diseases. In this review, we highlight the most recent advancements made with regard to Janus particles in point-of-care testing (POCT). Firstly, we introduce several commonly used methods for preparing Janus particles. Secondly, we present biomarker detection using JPs based on various detection methods to achieve the goal of POCT. Finally, we discuss the challenges and opportunities for developing Janus particles in POCT. This review will facilitate the development of POCT biosensing devices based on the unique properties of Janus particles.
Collapse
|
5
|
Singh S, Sharma M, Singh G. Recent advancements in urea biosensors for biomedical applications. IET Nanobiotechnol 2021; 15:358-379. [PMID: 34694714 PMCID: PMC8675831 DOI: 10.1049/nbt2.12050] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 01/06/2021] [Accepted: 02/14/2021] [Indexed: 12/22/2022] Open
Abstract
The quick progress in health care technology as a recurrent measurement of biochemical factors such as blood components leads to advance development and growth in biosensor technology necessary for effectual patient concern. The review wok of authors present a concise information and brief discussion on the development made in the progress of potentiometric, field effect transistor, graphene, electrochemical, optical, polymeric, nanoparticles and nanocomposites based urea biosensors in the past two decades. The work of authors is also centred on different procedures/methods for detection of urea by using amperometric, potentiometric, conductometric and optical processes, where graphene, polymer etc. are utilised as an immobilised material for the fabrication of biosensors. Further, a comparative revision has been accomplished on various procedures of urea analysis using different materials-based biosensors, and it discloses that electrochemical and potentiometric biosensor is the most promise one among all, in terms of rapid response time, extensive shelf life and resourceful design.
Collapse
Affiliation(s)
- Saravjeet Singh
- Department of Biomedical EngineeringDeenbandhu Chhotu Ram University of Science and TechnologyMurthalSonepatIndia
| | - Minakshi Sharma
- Department of ZoologyMaharishi Dayanand UniversityRohtakHaryanaIndia
| | - Geeta Singh
- Department of Biomedical EngineeringDeenbandhu Chhotu Ram University of Science and TechnologyMurthalSonepatIndia
| |
Collapse
|
6
|
Lozano-Torres B, Blandez JF, Galiana I, Lopez-Dominguez JA, Rovira M, Paez-Ribes M, González-Gualda E, Muñoz-Espín D, Serrano M, Sancenón F, Martínez-Máñez R. A Two-Photon Probe Based on Naphthalimide-Styrene Fluorophore for the In Vivo Tracking of Cellular Senescence. Anal Chem 2021; 93:3052-3060. [PMID: 33502178 PMCID: PMC8719760 DOI: 10.1021/acs.analchem.0c05447] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Accepted: 01/18/2021] [Indexed: 02/06/2023]
Abstract
Cellular senescence is a state of stable cell cycle arrest that can negatively affect the regenerative capacities of tissues and can contribute to inflammation and the progression of various aging-related diseases. Advances in the in vivo detection of cellular senescence are still crucial to monitor the action of senolytic drugs and to assess the early onset or accumulation of senescent cells. Here, we describe a naphthalimide-styrene-based probe (HeckGal) for the detection of cellular senescence both in vitro and in vivo. HeckGal is hydrolyzed by the increased lysosomal β-galactosidase activity of senescent cells, resulting in fluorescence emission. The probe was validated in vitro using normal human fibroblasts and various cancer cell lines undergoing senescence induced by different stress stimuli. Remarkably, HeckGal was also validated in vivo in an orthotopic breast cancer mouse model treated with senescence-inducing chemotherapy and in a renal fibrosis mouse model. In all cases, HeckGal allowed the unambiguous detection of senescence in vitro as well as in tissues and tumors in vivo. This work is expected to provide a potential technology for senescence detection in aged or damaged tissues.
Collapse
Affiliation(s)
- Beatriz Lozano-Torres
- Instituto
Interuniversitario de Investigación de Reconocimiento Molecular
y Desarrollo Tecnológico (IDM), Universitat
Politècnica de València-Universitat de València, Camí de Vera S/ N, Valencia 46022 Spain
- Unidad
Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades
y Nanomedicina, Universitat Politècnica
de València, Centro
de Investigación Príncipe Felipe, C/Eduardo Primo Yúfera
3, Valencia 46012, Spain
- CIBER
de Bioingeniería, Biomateriales y
Nanomedicina (CIBER-BBN), Av. Monforte de Lemos, 3-5. Pabellón 11. Planta 0, Madrid 28029, Spain
- Unidad
Mixta de Investigación en Nanomedicina y Sensores. Universitat Politècnica de València, IIS La Fe, Av. Fernando Abril Martorell,
10, Torre A 7a̲ planta, Valencia 46026, Spain
| | - Juan F Blandez
- Instituto
Interuniversitario de Investigación de Reconocimiento Molecular
y Desarrollo Tecnológico (IDM), Universitat
Politècnica de València-Universitat de València, Camí de Vera S/ N, Valencia 46022 Spain
- Unidad
Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades
y Nanomedicina, Universitat Politècnica
de València, Centro
de Investigación Príncipe Felipe, C/Eduardo Primo Yúfera
3, Valencia 46012, Spain
- Unidad
Mixta de Investigación en Nanomedicina y Sensores. Universitat Politècnica de València, IIS La Fe, Av. Fernando Abril Martorell,
10, Torre A 7a̲ planta, Valencia 46026, Spain
| | - Irene Galiana
- Instituto
Interuniversitario de Investigación de Reconocimiento Molecular
y Desarrollo Tecnológico (IDM), Universitat
Politècnica de València-Universitat de València, Camí de Vera S/ N, Valencia 46022 Spain
- Unidad
Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades
y Nanomedicina, Universitat Politècnica
de València, Centro
de Investigación Príncipe Felipe, C/Eduardo Primo Yúfera
3, Valencia 46012, Spain
- CIBER
de Bioingeniería, Biomateriales y
Nanomedicina (CIBER-BBN), Av. Monforte de Lemos, 3-5. Pabellón 11. Planta 0, Madrid 28029, Spain
- Unidad
Mixta de Investigación en Nanomedicina y Sensores. Universitat Politècnica de València, IIS La Fe, Av. Fernando Abril Martorell,
10, Torre A 7a̲ planta, Valencia 46026, Spain
| | - José A Lopez-Dominguez
- Institute
for Research in Biomedicine (IRB Barcelona), Barcelona Institute of Science and Technology (BIST), Carrer de Baldiri Reixac, 10, Barcelona 08028, Spain
| | - Miguel Rovira
- Institute
for Research in Biomedicine (IRB Barcelona), Barcelona Institute of Science and Technology (BIST), Carrer de Baldiri Reixac, 10, Barcelona 08028, Spain
| | - Marta Paez-Ribes
- CRUK Cancer
Centre Early Detection Programme, Department of Oncology, University of Cambridge, Hutchison/MRC Research Centre, Box 197, Cambridge CB2 0XZ, U.K.
| | - Estela González-Gualda
- CRUK Cancer
Centre Early Detection Programme, Department of Oncology, University of Cambridge, Hutchison/MRC Research Centre, Box 197, Cambridge CB2 0XZ, U.K.
| | - Daniel Muñoz-Espín
- CRUK Cancer
Centre Early Detection Programme, Department of Oncology, University of Cambridge, Hutchison/MRC Research Centre, Box 197, Cambridge CB2 0XZ, U.K.
| | - Manuel Serrano
- Institute
for Research in Biomedicine (IRB Barcelona), Barcelona Institute of Science and Technology (BIST), Carrer de Baldiri Reixac, 10, Barcelona 08028, Spain
- Catalan
Institution for Research and Advanced Studies (ICREA), Passeig Lluís Companys 23, 08010 Barcelona, Spain
| | - Félix Sancenón
- Instituto
Interuniversitario de Investigación de Reconocimiento Molecular
y Desarrollo Tecnológico (IDM), Universitat
Politècnica de València-Universitat de València, Camí de Vera S/ N, Valencia 46022 Spain
- Unidad
Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades
y Nanomedicina, Universitat Politècnica
de València, Centro
de Investigación Príncipe Felipe, C/Eduardo Primo Yúfera
3, Valencia 46012, Spain
- CIBER
de Bioingeniería, Biomateriales y
Nanomedicina (CIBER-BBN), Av. Monforte de Lemos, 3-5. Pabellón 11. Planta 0, Madrid 28029, Spain
- Unidad
Mixta de Investigación en Nanomedicina y Sensores. Universitat Politècnica de València, IIS La Fe, Av. Fernando Abril Martorell,
10, Torre A 7a̲ planta, Valencia 46026, Spain
| | - Ramón Martínez-Máñez
- Instituto
Interuniversitario de Investigación de Reconocimiento Molecular
y Desarrollo Tecnológico (IDM), Universitat
Politècnica de València-Universitat de València, Camí de Vera S/ N, Valencia 46022 Spain
- Unidad
Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades
y Nanomedicina, Universitat Politècnica
de València, Centro
de Investigación Príncipe Felipe, C/Eduardo Primo Yúfera
3, Valencia 46012, Spain
- CIBER
de Bioingeniería, Biomateriales y
Nanomedicina (CIBER-BBN), Av. Monforte de Lemos, 3-5. Pabellón 11. Planta 0, Madrid 28029, Spain
- Unidad
Mixta de Investigación en Nanomedicina y Sensores. Universitat Politècnica de València, IIS La Fe, Av. Fernando Abril Martorell,
10, Torre A 7a̲ planta, Valencia 46026, Spain
| |
Collapse
|
7
|
Pla L, Lozano-Torres B, Martínez-Máñez R, Sancenón F, Ros-Lis JV. Overview of the Evolution of Silica-Based Chromo-Fluorogenic Nanosensors. SENSORS (BASEL, SWITZERLAND) 2019; 19:E5138. [PMID: 31771224 PMCID: PMC6929179 DOI: 10.3390/s19235138] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 11/18/2019] [Accepted: 11/20/2019] [Indexed: 01/04/2023]
Abstract
This review includes examples of silica-based, chromo-fluorogenic nanosensors with the aim of illustrating the evolution of the discipline in recent decades through relevant research developed in our group. Examples have been grouped according to the sensing strategies. A clear evolution from simply functionalized materials to new protocols involving molecular gates and the use of highly selective biomolecules such as antibodies and oligonucleotides is reported. Some final examples related to the evolution of chromogenic arrays and the possible use of nanoparticles to communicate with other nanoparticles or cells are also included. A total of 64 articles have been summarized, highlighting different sensing mechanisms.
Collapse
Affiliation(s)
- Luis Pla
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain; (L.P.); (B.L.-T.); (F.S.)
- Unidad Mixta de Investigación en Nanomedicina y Sensores, Universitat Politècnica de València, IIS La Fe, Valencia, Spain
| | - Beatriz Lozano-Torres
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain; (L.P.); (B.L.-T.); (F.S.)
| | - Ramón Martínez-Máñez
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain; (L.P.); (B.L.-T.); (F.S.)
- Unidad Mixta de Investigación en Nanomedicina y Sensores, Universitat Politècnica de València, IIS La Fe, Valencia, Spain
- Unidad Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades y Nanomedicina, Valencia, Universitat Politècnica de València, Centro de Investigación Príncipe Felipe, València, Spain
| | - Félix Sancenón
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain; (L.P.); (B.L.-T.); (F.S.)
- Unidad Mixta de Investigación en Nanomedicina y Sensores, Universitat Politècnica de València, IIS La Fe, Valencia, Spain
- Unidad Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades y Nanomedicina, Valencia, Universitat Politècnica de València, Centro de Investigación Príncipe Felipe, València, Spain
| | - Jose V. Ros-Lis
- Departamento de Química Inorgánica, Universitat de València, Doctor Moliner 56, 46100 Valencia, Spain
| |
Collapse
|
8
|
Vardar G, Attar A, Yapaoz MA. Development of urea biosensor using non-covalent complexes of urease with aldehyde derivative of PEG and analysis on serum samples. Prep Biochem Biotechnol 2019; 49:868-875. [PMID: 31219372 DOI: 10.1080/10826068.2019.1630650] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Non-covalent complexes of urease/polyethylene glycol (PEG)-aldehyde were synthesized using regular molar ratios of urease and PEG-aldehyde at room temperature. The physical properties of the non-covalent complexes were analyzed in order to investigate the impact of coupling ratio, temperature, pH, storage stability, and thermal stability. Urease activity was analyzed by UV-Vis spectrophotometer at 630 nm. The results showed that the strongest thermal resistance was obtained using nU/nPEG:1/1 (mg/mL) complex within all molar ratios tested. The enzymatic activity of nU/nPEG:1/1 complex doubled the activity of the free enzyme. Therefore, this complex was chosen to be used in the analyses. When coupled with PEG-aldehyde, urease exhibited improved activity between pH 4.0-9.0 and the optimum pH was found to be 7.0. The thermal inactivation results of the complex demonstrated that higher activity remained (40%) when compared with the free enzyme (10%) at 60 °C. The storage stability of the non-covalent complex was 4 weeks which was greater than the storage stability of the free enzyme. A kinetic model was suggested in order to reveal the mechanism of enzymatic conversion. Potentiometric urea biosensor was prepared using two different membranes: carboxylated poly vinyl chloride (PVC) and palmitic acid containing PVC. The potentiometric responses of both sensors were tested against pH and temperature and the best results were obtained at pH 7.0 and 20-30 °C. Also, selectivity of the suggested biosensors toward Na+, Li+ Ca2+, and K+ ions was evaluated and the reproducibility responses of the urea biosensors were measured with acceptable results.
Collapse
Affiliation(s)
- Gokay Vardar
- Department of Chemistry, Faculty of Science and Letters, Yildiz Technical University , Istanbul , Turkey
| | - Azade Attar
- Department of Bioengineering, Faculty of Chemical & Metallurgical Engineering, Yildiz Technical University , Istanbul , Turkey
| | - Melda Altikatoglu Yapaoz
- Department of Chemistry, Faculty of Science and Letters, Yildiz Technical University , Istanbul , Turkey
| |
Collapse
|