1
|
Grolman E, Sirianni QEA, Dunmore-Buyze J, Cruje C, Drangova M, Gillies ER. Depolymerizing self-immolative polymeric lanthanide chelates for vascular imaging. Acta Biomater 2023; 169:530-541. [PMID: 37507034 DOI: 10.1016/j.actbio.2023.07.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 07/03/2023] [Accepted: 07/22/2023] [Indexed: 07/30/2023]
Abstract
Medical imaging is widely used clinically and in research to understand disease progression and monitor responses to therapies. Vascular imaging enables the study of vascular disease and therapy, but exogenous contrast agents are generally needed to distinguish the vasculature from surrounding soft tissues. Lanthanide-based agents are commonly employed in MRI, but are also of growing interest for micro-CT, as the position of their k-edges allows them to provide enhanced contrast and also to be employed in dual-energy micro-CT, a technique that can distinguish contrast-enhanced blood vessels from tissues such as bone. Small molecule Gd3+ chelates are available, but are excreted too rapidly. At the same time, a lack of rapid clearance from the body for long-circulating agents presents toxicity concerns. To address these challenges, we describe here the use of self-immolative polymers for the development of new degradable chelates that depolymerize completely from end-to-end following the cleavage of a single end-cap from the polymer terminus. We demonstrate that tuning the end-cap allows the rate of depolymerization to be controlled, while tuning the polymer length enables the polymer to exhibit long circulation times in the blood of mice. After successfully providing one hour of blood contrast, depolymerization led to excretion of the resulting small molecule chelates into the bladder. Despite the high doses required for micro-CT, the agents were well tolerated in mice. Thus, these self-immolative polymeric chelates provide a new platform for the development of medical imaging contrast agents. STATEMENT OF SIGNIFICANCE: Vascular imaging is used clinically to diagnose and monitor vascular disease and in research to understand the progression of disease and study responses to new therapies. For techniques such as magnetic resonance imaging and x-ray computed tomography (CT), long circulating contrast agents are needed to differentiate the vasculature from surrounding tissues. However, if these agents are not rapidly excreted from the body, they can lead to toxicity. We present here a new polymeric system that can chelate hundreds of lanthanide ions for imaging contrast and can circulate for one hour in the blood, but then after end-cap cleavage breaks down completely into small molecules for excretion. The successful application of this system in micro-CT in mice is demonstrated.
Collapse
Affiliation(s)
- Eric Grolman
- School of Biomedical Engineering, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B9, Canada; Robarts Research Institute, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada
| | - Quinton E A Sirianni
- Department of Chemistry, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada
| | - Joy Dunmore-Buyze
- Robarts Research Institute, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada
| | - Charmainne Cruje
- Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5C1, Canada
| | - Maria Drangova
- School of Biomedical Engineering, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B9, Canada; Robarts Research Institute, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada; Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5C1, Canada.
| | - Elizabeth R Gillies
- School of Biomedical Engineering, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B9, Canada; Department of Chemistry, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B7, Canada; Department of Chemical and Biochemical Engineering, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 5B9, Canada.
| |
Collapse
|
2
|
Redente EF, Kopf KW, Bahadur AN, Robichaud A, Lundblad LK, McDonald LT. Application-specific approaches to MicroCT for evaluation of mouse models of pulmonary disease. PLoS One 2023; 18:e0281452. [PMID: 36757935 PMCID: PMC9910664 DOI: 10.1371/journal.pone.0281452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 01/23/2023] [Indexed: 02/10/2023] Open
Abstract
The advent of micro-computed tomography (microCT) has provided significant advancement in our ability to generate clinically relevant assessments of lung health and disease in small animal models. As microCT use to generate outcomes analysis in pulmonary preclinical models has increased there have been substantial improvements in image quality and resolution, and data analysis software. However, there are limited published methods for standardized imaging and automated analysis available for investigators. Manual quantitative analysis of microCT images is complicated by the presence of inflammation and parenchymal disease. To improve the efficiency and limit user-associated bias, we have developed an automated pulmonary air and tissue segmentation (PATS) task list to segment lung air volume and lung tissue volume for quantitative analysis. We demonstrate the effective use of the PATS task list using four distinct methods for imaging, 1) in vivo respiration controlled scanning using a flexiVent, 2) longitudinal breath-gated in vivo scanning in resolving and non-resolving pulmonary disease initiated by lipopolysaccharide-, bleomycin-, and silica-exposure, 3) post-mortem imaging, and 4) ex vivo high-resolution scanning. The accuracy of the PATS task list was compared to manual segmentation. The use of these imaging techniques and automated quantification methodology across multiple models of lung injury and fibrosis demonstrates the broad applicability and adaptability of microCT to various lung diseases and small animal models and presents a significant advance in efficiency and standardization of preclinical microCT imaging and analysis for the field of pulmonary research.
Collapse
Affiliation(s)
- Elizabeth F. Redente
- Department of Pediatrics, National Jewish Health, Denver, Colorado, United States of America
- Department of Medicine, University of Colorado Anschutz Medical Campus, Aurora, Colorado, United States of America
- * E-mail:
| | - Katrina W. Kopf
- Department of Academic Affairs, National Jewish Health, Denver, Colorado, United States of America
| | - Ali N. Bahadur
- Bruker BioSpin Corporation, Billerica, Massachusetts, United States of America
| | | | | | - Lindsay T. McDonald
- Ralph H. Johnson VA Medical Center, Charleston, South Carolina, United States of America
| |
Collapse
|
3
|
PEG-modified gadolinium nanoparticles as contrast agents for in vivo micro-CT. Sci Rep 2021; 11:16603. [PMID: 34400681 PMCID: PMC8367985 DOI: 10.1038/s41598-021-95716-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 07/09/2021] [Indexed: 12/30/2022] Open
Abstract
Vascular research is largely performed in rodents with the goal of developing treatments for human disease. Micro-computed tomography (micro-CT) provides non-destructive three-dimensional imaging that can be used to study the vasculature of rodents. However, to distinguish vasculature from other soft tissues, long-circulating contrast agents are required. In this study, we demonstrated that poly(ethylene glycol) (PEG)-coated gadolinium nanoparticles can be used as a vascular contrast agent in micro-CT. The coated particles could be lyophilized and then redispersed in an aqueous solution to achieve 100 mg/mL of gadolinium. After an intravenous injection of the contrast agent into mice, micro-CT scans showed blood pool contrast enhancements of at least 200 HU for 30 min. Imaging and quantitative analysis of gadolinium in tissues showed the presence of contrast agent in clearance organs including the liver and spleen and very low amounts in other organs. In vitro cell culture experiments, subcutaneous injections, and analysis of mouse body weight suggested that the agents exhibited low toxicity. Histological analysis of tissues 5 days after injection of the contrast agent showed cytotoxicity in the spleen, but no abnormalities were observed in the liver, lungs, kidneys, and bladder.
Collapse
|
4
|
El Ketara S, Ford NL. Time-course study of a gold nanoparticle contrast agent for cardiac-gated micro-CT imaging in mice. Biomed Phys Eng Express 2020; 6:035025. [PMID: 33438670 DOI: 10.1088/2057-1976/ab8741] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Although micro-computed tomography (micro-CT) images have high contrast for bone or air, between soft tissues the contrast is typically low. To overcome this inherent issue, attenuating exogenous contrast agents are used to provide contrast enhancement in the vasculature and abdominal organs. The aim of this study is to measure the contrast enhancement time course for a gold nanoparticle blood-pool contrast agent and use it to perform cardiac-gated 4D micro-CT scans of the heart. Six healthy female C57BL/6 mice were anesthetized and imaged after receiving an injected dose of MVivo gold nanoparticle blood-pool contrast agent. Following the injection, we performed micro-CT scans at 0, 0.25, 0.5, 0.75, 1, 2, 4, 8, 24, 48 and 72 h. The mean CT number was measured for 7 different organs. No contrast enhancement was noticed in the bladder, kidneys or muscle during the time-course study. However, it clearly appears that the contrast enhancement is high in both right ventricle and vena cava. To perform cardiac-gated imaging, either the gold nanoparticle agent (n = 3) or an iodine-based (n = 3) contrast agent was introduced and images representing 9 phases of the cardiac cycle were obtained in 6 additional mice. A few typical cardiac parameters were measured or calculated, with similar accuracy between the gold and iodinated agents, but better visualization of structures with the gold agent. The MVivo Au contrast agent can be used for investigations of cardiac or vascular disease with a single bolus injection, with an optimal cardiac imaging window identified during the first hour after injection, demonstrating similar image quality to iodinated contrast agents and excellent measurement accuracy. Furthermore, the long-lasting contrast enhancement of up to 8 h can be very useful for scanning protocols that require longer acquisition times.
Collapse
Affiliation(s)
- Samir El Ketara
- Oral Biological and Medical Sciences, The University of British Columbia, Vancouver, Canada. Université Grenobles Alpes, Grenoble, France
| | | |
Collapse
|
5
|
Numerical simulation of novel concept 4D cardiac microtomography for small rodents based on all-optical Thomson scattering X-ray sources. Sci Rep 2019; 9:8439. [PMID: 31186451 PMCID: PMC6560041 DOI: 10.1038/s41598-019-44779-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 05/20/2019] [Indexed: 12/17/2022] Open
Abstract
Accurate dynamic three-dimensional (4D) imaging of the heart of small rodents is required for the preclinical study of cardiac biomechanics and their modification under pathological conditions, but technological challenges are met in laboratory practice due to the very small size and high pulse rate of the heart of mice and rats as compared to humans. In 4D X-ray microtomography (4D μCT), the achievable spatio-temporal resolution is hampered by limitations in conventional X-ray sources and detectors. Here, we propose a proof-of-principle 4D μCT platform, exploiting the unique spatial and temporal features of novel concept, all-optical X-ray sources based on Thomson scattering (TS). The main spatial and spectral properties of the photon source are investigated using a TS simulation code. The entire data acquisition workflow has been also simulated, using a novel 4D numerical phantom of a mouse chest with realistic intra- and inter-cycle motion. The image quality of a typical single 3D time frame has been studied using Monte Carlo simulations, taking into account the effects of the typical structure of the TS X-ray beam. Finally, we discuss the perspectives and shortcomings of the proposed platform.
Collapse
|
6
|
In Vivo Detection and Measurement of Aortic Aneurysm and Dissection in Mouse Models Using Microcomputed Tomography with Contrast Agent. CONTRAST MEDIA & MOLECULAR IMAGING 2019; 2019:5940301. [PMID: 30956627 PMCID: PMC6431409 DOI: 10.1155/2019/5940301] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Accepted: 02/11/2019] [Indexed: 02/03/2023]
Abstract
Objectives The aim of this study was to evaluate the potential of microcomputed tomography (micro-CT) using the intravascular contrast agent ExiTron nano 12000 for aorta imaging and monitoring the dynamic changing process of the aorta in mouse models with aortic aneurysm and dissection. Materials and Methods Experiments were performed on healthy mice and mice with aortic dissection. Mice that were developing aortic dissection and healthy mice underwent micro-CT imaging after injection of ExiTron nano 12000. Time-dependent signal enhancement (at 1, 2, 3, 6, and 12 hours after intravenous injection of the contrast agent, respectively) in the aorta of healthy mice was measured to confirm the optimal imaging time of aorta. Various contrast agent doses (70, 100, and 150 μl per 25 g mouse, respectively) were investigated to determine the optimal required dose for imaging of the aorta. The mice were scanned with micro-CT at 1, 14, and 28 days after onset of aneurysm and dissection to monitor the dynamic changing process of the aorta. Mouse aortas were stained with hematoxylin and eosin staining, and the diameter of the aorta was measured and compared with those obtained by micro-CT. Results Time-dependent signal enhancement in the aorta shows that the contrast agent has a long blood half-life of 6 hours, with a peak enhancement at 2 hours after injection. Injection of 100 μl ExiTron nano 12000 per 25 g mouse allows for effective visualization of the aorta. Micro-CT combined with contrast agent can monitor the changing process of the aorta in the mouse model of aortic aneurysm and dissection dynamically. The values of the diameter of the aortas obtained from the in vivo micro-CT imaging were compared with those obtained from histology and showed a significant correlation (R2 = 0.96). Conclusions These data demonstrate that in vivo micro-CT is an accurate and feasible technique to detect aortic aneurysm or dissection in a mouse model, and the micro-CT technique using the innovative contrast agent ExiTron nano 12000 allows for monitoring various processes dynamically such as aortic remodeling in longitudinal studies.
Collapse
|
7
|
Cruje C, Dunmore-Buyze J, MacDonald JP, Holdsworth DW, Drangova M, Gillies ER. Polymer Assembly Encapsulation of Lanthanide Nanoparticles as Contrast Agents for In Vivo Micro-CT. Biomacromolecules 2018; 19:896-905. [PMID: 29438616 DOI: 10.1021/acs.biomac.7b01685] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Despite recent technological advancements in microcomputed tomography (micro-CT) and contrast agent development, preclinical contrast agents are still predominantly iodine-based. Higher contrast can be achieved when using elements with higher atomic numbers, such as lanthanides; lanthanides also have X-ray attenuation properties that are ideal for spectral CT. However, the formulation of lanthanide-based contrast agents at the high concentrations required for vascular imaging presents a significant challenge. In this work, we developed an erbium-based contrast agent that meets micro-CT imaging requirements, which include colloidal stability upon redispersion at high concentrations, evasion of rapid renal clearance, and circulation times of tens of minutes in small animals. Through systematic studies with poly(ethylene glycol) (PEG)-poly(propylene glycol), PEG-polycaprolactone, and PEG-poly(l-lactide) (PLA) block copolymers, the amphiphilic block copolymer PEG114-PLA53 was identified to be ideal for encapsulating oleate-coated lanthanide-based nanoparticles for in vivo intravenous administration. We were able to synthesize a contrast agent containing 100 mg/mL of erbium that could be redispersed into colloidally stable particles in saline after lyophilization. Contrast enhancement of over 250 HU was achieved in the blood pool for up to an hour, thereby meeting the requirements of live animal micro-CT.
Collapse
|
8
|
Erbium-Based Perfusion Contrast Agent for Small-Animal Microvessel Imaging. CONTRAST MEDIA & MOLECULAR IMAGING 2017; 2017:7368384. [PMID: 29270099 PMCID: PMC5705880 DOI: 10.1155/2017/7368384] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Revised: 09/11/2017] [Accepted: 10/02/2017] [Indexed: 12/17/2022]
Abstract
Micro-computed tomography (micro-CT) facilitates the visualization and quantification of contrast-enhanced microvessels within intact tissue specimens, but conventional preclinical vascular contrast agents may be inadequate near dense tissue (such as bone). Typical lead-based contrast agents do not exhibit optimal X-ray absorption properties when used with X-ray tube potentials below 90 kilo-electron volts (keV). We have developed a high-atomic number lanthanide (erbium) contrast agent, with a K-edge at 57.5 keV. This approach optimizes X-ray absorption in the output spectral band of conventional microfocal spot X-ray tubes. Erbium oxide nanoparticles (nominal diameter < 50 nm) suspended in a two-part silicone elastomer produce a perfusable fluid with viscosity of 19.2 mPa-s. Ultrasonic cavitation was used to reduce aggregate sizes to <70 nm. Postmortem intact mice were perfused to investigate the efficacy of contrast agent. The observed vessel contrast was >4000 Hounsfield units, and perfusion of vessels < 10 μm in diameter was demonstrated in kidney glomeruli. The described new contrast agent facilitated the visualization and quantification of vessel density and microarchitecture, even adjacent to dense bone. Erbium's K-edge makes this contrast agent ideally suited for both single- and dual-energy micro-CT, expanding potential preclinical research applications in models of musculoskeletal, oncological, cardiovascular, and neurovascular diseases.
Collapse
|
9
|
In Vivo Quantification of Myocardial Infarction in Mice Using Micro-CT and a Novel Blood Pool Agent. CONTRAST MEDIA & MOLECULAR IMAGING 2017; 2017:2617047. [PMID: 29114173 PMCID: PMC5662822 DOI: 10.1155/2017/2617047] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2017] [Accepted: 09/12/2017] [Indexed: 11/25/2022]
Abstract
We herein developed a micro-CT method using the innovative contrast agent ExiTron™ MyoC 8000 to longitudinally monitor cardiac processes in vivo in small animals. Experiments were performed on healthy mice and mice with myocardial infarction inflicted by ligation of the left anterior descending artery. Time-dependent signal enhancement in different tissues of healthy mice was measured and various contrast agent doses were investigated so as to determine the minimum required dose for imaging of the myocardium. Due to its ability to be taken up by healthy myocardium but not by infarct tissue, ExiTron MyoC 8000 enables detection of myocardial infarction even at a very low dose. The signal enhancement in the myocardium of infarcted mice after contrast agent injection was exploited for quantification of infarct size. The values of infarct size obtained from the imaging method were compared with those obtained from histology and showed a significant correlation (R2 = 0.98). Thus, the developed micro-CT method allows for monitoring of a variety of processes such as cardiac remodeling in longitudinal studies.
Collapse
|
10
|
Mannheim JG, Schlichthaerle T, Kuebler L, Quintanilla-Martinez L, Kohlhofer U, Kneilling M, Pichler BJ. Comparison of small animal CT contrast agents. CONTRAST MEDIA & MOLECULAR IMAGING 2016; 11:272-84. [PMID: 26991457 DOI: 10.1002/cmmi.1689] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Revised: 12/21/2015] [Accepted: 01/16/2016] [Indexed: 11/09/2022]
Abstract
Non-invasive in vivo small animal computed tomography (CT) imaging provides high resolution bone scans but cannot differentiate between soft tissues. For most applications injections of contrast agents (CAs) are necessary. Aim of this study was to uncover the advantages and disadvantages of commercially available CT CAs (ExiTron nano 12 000 and 6000, eXIA 160 and 160XL, Fenestra VC and LC) regarding their pharmacokinetics, toxicological side-effects and the influence of anesthesia on the biodistribution, based on an injection volume of 100 μL/25 g body weight. The pharmacokinetics of the CAs were determined for up to five days. The CA-induced toxicological/physiological side-effects were evaluated by determining blood counts, liver enzymes, thyroxine and total protein values, pro-inflammatory mediators (messenger ribonucleic acid (mRNA)), histology and immunohistochemistry. ExiTron nano 12 000 and 6000 yielded a long-term contrast enhancement (CE) in the liver and spleen for up to five days. Some of the evaluated CAs did not show any CE at all. Anesthesia did not impair the CAs' biodistribution. The CAs differentially affected the body weight, blood counts, liver enzymes, thyroxine and total protein values. ExiTron nano 12 000 and 6000 induced histiocytes in the liver and spleen. Moreover, ExiTron nano 12 000 and eXIA 160 enhanced tumor necrosis factor (TNF) mRNA expression levels in the kidneys. Thus, we recommend ExiTron nano 12 000 and 6000 when multiple injections should be avoided. We recommend careful selection of the employed CA in order to achieve an acceptable CE in the organs of interest and to avoid influences on the animal physiology. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Julia G Mannheim
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Thomas Schlichthaerle
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Tuebingen, Germany.,Max Planck Institute of Biochemistry, Martinsried, Germany
| | - Laura Kuebler
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | | | - Ursula Kohlhofer
- Institute of Pathology, University Hospital Tuebingen, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Manfred Kneilling
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Tuebingen, Germany.,Department of Dermatology, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Bernd J Pichler
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Tuebingen, Germany
| |
Collapse
|
11
|
van Deel E, Ridwan Y, van Vliet JN, Belenkov S, Essers J. In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography. J Vis Exp 2016:53603. [PMID: 26967592 PMCID: PMC4828165 DOI: 10.3791/53603] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
The use of Micro-Computed Tomography (MicroCT) for in vivo studies of small animals as models of human disease has risen tremendously due to the fact that MicroCT provides quantitative high-resolution three-dimensional (3D) anatomical data non-destructively and longitudinally. Most importantly, with the development of a novel preclinical iodinated contrast agent called eXIA160, functional and metabolic assessment of the heart became possible. However, prior to the advent of commercial MicroCT scanners equipped with X-ray flat-panel detector technology and easy-to-use cardio-respiratory gating, preclinical studies of cardiovascular disease (CVD) in small animals required a MicroCT technologist with advanced skills, and thus were impractical for widespread implementation. The goal of this work is to provide a practical guide to the use of the high-speed Quantum FX MicroCT system for comprehensive determination of myocardial global and regional function along with assessment of myocardial perfusion, metabolism and viability in healthy mice and in a cardiac ischemia mouse model induced by permanent occlusion of the left anterior descending coronary artery (LAD).
Collapse
Affiliation(s)
- Elza van Deel
- Department of Genetics, Erasmus MC, Rotterdam; Department of Experimental Cardiology, Erasmus MC, Rotterdam
| | | | | | | | - Jeroen Essers
- Department of Genetics, Erasmus MC, Rotterdam; Department of Vascular Surgery, Erasmus MC, Rotterdam; Department of Radiation Oncology, Erasmus MC, Rotterdam;
| |
Collapse
|
12
|
Rothe JH, Rudolph I, Rohwer N, Kupitz D, Gregor-Mamoudou B, Derlin T, Furth C, Amthauer H, Brenner W, Buchert R, Cramer T, Apostolova I. Time course of contrast enhancement by micro-CT with dedicated contrast agents in normal mice and mice with hepatocellular carcinoma: comparison of one iodinated and two nanoparticle-based agents. Acad Radiol 2015; 22:169-78. [PMID: 25282584 DOI: 10.1016/j.acra.2014.07.022] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 07/27/2014] [Accepted: 07/28/2014] [Indexed: 11/16/2022]
Abstract
RATIONALE AND OBJECTIVES The aim of the present study was to characterize the kinetics of two nanoparticle-based contrast agents for preclinical imaging, Exitron nano 6000 and Exitron nano 12000, and the iodinated agent eXIA 160 in both healthy mice and in a mouse model of hepatocellular carcinoma (HCC). Semiautomatic segmentation of liver lesions for estimation of total tumor load of the liver was evaluated in HCC mice. MATERIALS AND METHODS The normal time course of contrast enhancement was assessed in 15 healthy C57BL/6 mice. Imaging of tumor spread in the liver was evaluated in 15 mice harboring a transgenic HCC model (ASV-B mice). Automatic segmentation of liver lesions for determination of total tumor burden of the liver was tested in three additional ASV-B mice before and after an experimental therapy. RESULTS In healthy mice, clearance of the contrast agent from blood was completed within 3-4 hours for eXIA 160 and Exitron nano 6000, whereas complete blood clearance of Exitron nano 12000 required about 24 hours. eXIA 160 provided maximum liver contrast at 1 hour post injection (p.i.) followed by a continuous decline. Enhancement of liver contrast with Exitron nano 6000 and Exitron nano 12000 reached a plateau at about 4 hours p.i., which lasted until the end of the measurements at 96 hours p.i. Maximum contrast enhancement of the liver was not statistically different between Exitron nano 6000 and Exitron nano 12000, but was about three times lower for eXIA 160 (P < .05). Visually Exitron nano 12000 provided the best liver-to-tumor contrast. Semiautomatic liver and tumor segmentation was feasible after the administration of Exitron nano 12000 but did not work properly for the other two contrast agents. CONCLUSIONS Both nanoparticle-based contrast agents provided stronger and longer lasting contrast enhancement of healthy liver parenchyma. Exitron nano 12000 allowed automatic segmentation of tumor lesions for estimation of the total tumor load in the liver.
Collapse
Affiliation(s)
- Jan H Rothe
- Clinic of Nuclear Medicine, University Medicine Charité, Berlin, Germany
| | - Ines Rudolph
- Clinic of Hepatology and Gastroenterology, University Medicine Charité, Berlin, Germany; German Cancer Consortium, Deutsches Krebsforschungzentrum (DKFZ), Heidelberg, Germany
| | - Nadine Rohwer
- Clinic of Hepatology and Gastroenterology, University Medicine Charité, Berlin, Germany
| | - Dennis Kupitz
- Department of Radiology and Nuclear Medicine, Medical School, Otto-von-Guericke University, Magdeburg A.ö.R., Magdeburg, Germany
| | | | - Thorsten Derlin
- Clinic of Radiology, University Medical Center, Hamburg, Germany
| | - Christian Furth
- Department of Radiology and Nuclear Medicine, Medical School, Otto-von-Guericke University, Magdeburg A.ö.R., Magdeburg, Germany
| | - Holger Amthauer
- Department of Radiology and Nuclear Medicine, Medical School, Otto-von-Guericke University, Magdeburg A.ö.R., Magdeburg, Germany
| | - Winfried Brenner
- Clinic of Nuclear Medicine, University Medicine Charité, Berlin, Germany
| | - Ralph Buchert
- Clinic of Nuclear Medicine, University Medicine Charité, Berlin, Germany
| | - Thorsten Cramer
- Clinic of Hepatology and Gastroenterology, University Medicine Charité, Berlin, Germany
| | - Ivayla Apostolova
- Department of Radiology and Nuclear Medicine, Medical School, Otto-von-Guericke University, Magdeburg A.ö.R., Magdeburg, Germany.
| |
Collapse
|
13
|
Ashton JR, Befera N, Clark D, Qi Y, Mao L, Rockman HA, Johnson GA, Badea CT. Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent. CONTRAST MEDIA & MOLECULAR IMAGING 2014; 9:161-8. [PMID: 24523061 DOI: 10.1002/cmmi.1557] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2012] [Revised: 05/10/2013] [Accepted: 06/17/2013] [Indexed: 11/09/2022]
Abstract
Noninvasive small animal imaging techniques are essential for evaluation of cardiac disease and potential therapeutics. A novel preclinical iodinated contrast agent called eXIA 160 has recently been developed, which has been evaluated for micro-CT cardiac imaging. eXIA 160 creates strong contrast between blood and tissue immediately after its injection and is subsequently taken up by the myocardium and other metabolically active tissues over time. We focus on these properties of eXIA and show its use in imaging myocardial infarction in mice. Five C57BL/6 mice were imaged ~2 weeks after left anterior descending coronary artery ligation. Six C57BL/6 mice were used as controls. Immediately after injection of eXIA 160, an enhancement difference between blood and myocardium of ~340 HU enabled cardiac function estimation via 4D micro-CT scanning with retrospective gating. Four hours post-injection, the healthy perfused myocardium had a contrast difference of ~140 HU relative to blood while the infarcted myocardium showed no enhancement. These differences allowed quantification of infarct size via dual-energy micro-CT. In vivo micro-SPECT imaging and ex vivo triphenyl tetrazolium chloride (TTC) staining provided validation for the micro-CT findings. Root mean squared error of infarct measurements was 2.7% between micro-CT and SPECT, and 4.7% between micro-CT and TTC. Thus, micro-CT with eXIA 160 can be used to provide both morphological and functional data for preclinical studies evaluating myocardial infarction and potential therapies. Further studies are warranted to study the potential use of eXIA 160 as a CT molecular imaging tool for other metabolically active tissues in the mouse.
Collapse
Affiliation(s)
- Jeffrey R Ashton
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Durham, NC, 27710, USA
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Clark DP, Badea CT. Micro-CT of rodents: state-of-the-art and future perspectives. Phys Med 2014; 30:619-34. [PMID: 24974176 PMCID: PMC4138257 DOI: 10.1016/j.ejmp.2014.05.011] [Citation(s) in RCA: 134] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 05/15/2014] [Accepted: 05/28/2014] [Indexed: 02/06/2023] Open
Abstract
Micron-scale computed tomography (micro-CT) is an essential tool for phenotyping and for elucidating diseases and their therapies. This work is focused on preclinical micro-CT imaging, reviewing relevant principles, technologies, and applications. Commonly, micro-CT provides high-resolution anatomic information, either on its own or in conjunction with lower-resolution functional imaging modalities such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). More recently, however, advanced applications of micro-CT produce functional information by translating clinical applications to model systems (e.g., measuring cardiac functional metrics) and by pioneering new ones (e.g. measuring tumor vascular permeability with nanoparticle contrast agents). The primary limitations of micro-CT imaging are the associated radiation dose and relatively poor soft tissue contrast. We review several image reconstruction strategies based on iterative, statistical, and gradient sparsity regularization, demonstrating that high image quality is achievable with low radiation dose given ever more powerful computational resources. We also review two contrast mechanisms under intense development. The first is spectral contrast for quantitative material discrimination in combination with passive or actively targeted nanoparticle contrast agents. The second is phase contrast which measures refraction in biological tissues for improved contrast and potentially reduced radiation dose relative to standard absorption imaging. These technological advancements promise to develop micro-CT into a commonplace, functional and even molecular imaging modality.
Collapse
Affiliation(s)
- D P Clark
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Box 3302, Durham, NC 27710, USA
| | - C T Badea
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Box 3302, Durham, NC 27710, USA.
| |
Collapse
|
15
|
Willekens I, Buls N, Maeseneer MD, Lahoutte T, de Mey J. Use of eXIA 160 XL for Contrast Studies in Micro–Computed Tomography: Experimental Observations. Mol Imaging 2013. [DOI: 10.2310/7290.2013.00050] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Affiliation(s)
- Inneke Willekens
- From In Vivo Cellular and Molecular Imaging, Vrije Universiteit Brussel, and Departments of Radiology and Nuclear Medicine, UZ Brussel, Brussels, Belgium
| | - Nico Buls
- From In Vivo Cellular and Molecular Imaging, Vrije Universiteit Brussel, and Departments of Radiology and Nuclear Medicine, UZ Brussel, Brussels, Belgium
| | - Michel De Maeseneer
- From In Vivo Cellular and Molecular Imaging, Vrije Universiteit Brussel, and Departments of Radiology and Nuclear Medicine, UZ Brussel, Brussels, Belgium
| | - Tony Lahoutte
- From In Vivo Cellular and Molecular Imaging, Vrije Universiteit Brussel, and Departments of Radiology and Nuclear Medicine, UZ Brussel, Brussels, Belgium
| | - Johan de Mey
- From In Vivo Cellular and Molecular Imaging, Vrije Universiteit Brussel, and Departments of Radiology and Nuclear Medicine, UZ Brussel, Brussels, Belgium
| |
Collapse
|
16
|
Detombe SA, Dunmore-Buyze J, Petrov IE, Drangova M. X-ray dose delivered during a longitudinal micro-CT study has no adverse effect on cardiac and pulmonary tissue in C57BL/6 mice. Acta Radiol 2013; 54:435-41. [PMID: 23436828 DOI: 10.1177/0284185113475608] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
BACKGROUND Micro-computed tomography (micro-CT) offers numerous advantages for small animal imaging, including the ability to monitor the same animals throughout a longitudinal study. However, concerns are often raised regarding the effects of X-ray dose accumulated over the course of the experiment. PURPOSE To scan C57BL/6 mice multiple times per week for 6 weeks, in order to determine the effect of the cumulative dose on pulmonary and cardiac tissue at the end of the study. MATERIAL AND METHODS C57BL/6 male mice were split into two groups (irradiated group = 10, control group = 10). The irradiated group was scanned (80 kVp/50 mA) three times weekly for 6 weeks, resulting in a weekly dose of 0.84 Gy, and a total study dose of 5.04 Gy. The control group was scanned on the final week. Scans from week 6 were reconstructed and the lungs and heart were analyzed. RESULTS Overall, there was no significant difference in lung volume or lung density or in left ventricular volume or ejection fraction between the control group and the irradiated group. Histological samples taken from excised lung and myocardial tissue also showed no evidence of inflammation or fibrosis in the irradiated group. CONCLUSION This study demonstrated that a 5 Gy X-ray dose accumulated over 6 weeks during a longitudinal micro-CT study had no significant effects on the pulmonary and myocardial tissue of C57BL/6 mice. As a result, the many advantages of micro-CT imaging, including rapid acquisition of high-resolution, isotropic images in free-breathing mice, can be taken advantage of in longitudinal studies without concern for negative dose-related effects.
Collapse
Affiliation(s)
- Sarah A Detombe
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, ON
- Department of Medical Biophysics, Western University, London, ON, Canada
| | - Joy Dunmore-Buyze
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, ON
| | - Ivailo E Petrov
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, ON
| | - Maria Drangova
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, ON
- Department of Medical Biophysics, Western University, London, ON, Canada
| |
Collapse
|
17
|
Cardiac Micro-PET-CT. CURRENT CARDIOVASCULAR IMAGING REPORTS 2013. [DOI: 10.1007/s12410-012-9188-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
18
|
Guzman MS, De Jaeger X, Drangova M, Prado MAM, Gros R, Prado VF. Mice with selective elimination of striatal acetylcholine release are lean, show altered energy homeostasis and changed sleep/wake cycle. J Neurochem 2013; 124:658-69. [PMID: 23240572 DOI: 10.1111/jnc.12128] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2012] [Revised: 11/20/2012] [Accepted: 12/07/2012] [Indexed: 01/21/2023]
Abstract
Cholinergic neurons are known to regulate striatal circuits; however, striatal-dependent physiological outcomes influenced by acetylcholine (ACh) are still poorly under;?>stood. Here, we used vesicular acetylcholine transporter (VAChT)(D2-Cre-flox/flox) mice, in which we selectively ablated the vesicular acetylcholine transporter in the striatum to dissect the specific roles of striatal ACh in metabolic homeostasis. We report that VAChT(D) (2-Cre-flox/flox) mice are lean at a young age and maintain this lean phenotype with time. The reduced body weight observed in these mutant mice is not attributable to reduced food intake or to a decrease in growth rate. In addition, changed activity could not completely explain the lean phenotype, as only young VAChT(D) (2-Cre-flox/flox) mice showed increased physical activity. Interestingly, VAChT(D) (2-Cre-flox/flox) mice show several metabolic changes, including increased plasma levels of insulin and leptin. They also show increased periods of wakefulness when compared with littermate controls. Taken together, our data suggest that striatal ACh has an important role in the modulation of metabolism and highlight the importance of striatum cholinergic tone in the regulation of energy expenditure. These new insights on how cholinergic neurons influence homeostasis open new avenues for the search of drug targets to treat obesity.
Collapse
Affiliation(s)
- Monica S Guzman
- Robarts Research Institute, Schulich School of Medicine & Dentistry, University of Western Ontario, London, Ontario, Canada
| | | | | | | | | | | |
Collapse
|