1
|
Zhang W, Han Z, Zhao Z, Shi J, Liu L, Wang D, Yu Z. Rapid detection of furanyl fentanyl in complex matrices using Leidenfrost desorption-assisted low-temperature arc plasma ionization mass spectrometry. Analyst 2024; 149:2762-2768. [PMID: 38567533 DOI: 10.1039/d4an00222a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
The abuse of illicit drugs poses serious threats to the physical and mental health of users, as well as to the overall safety and welfare of society. In this work, we present a newly developed technique for drug detection based on mass spectrometry. This technique combines Leidenfrost desorption with low-temperature arc plasma ionization mass spectrometry. This method is applicable for detecting furanyl fentanyl in complex matrices. Key advantages of this technique include minimal sample fragmentation and high sensitivity for detection. The Leidenfrost desorption plays a pivotal role in this methodology, as it spontaneously concentrates analyte molecules during the gradual evaporation of the solvent. Eventually, these concentrated molecules are redistributed at their highest concentrations, resulting in exceptionally high sensitivity. In the course of our investigation, we achieved a remarkable detection limit of 10 pg mL-1 for furanyl fentanyl in pure water. Moreover, the characteristic ion peaks of furanyl fentanyl can be distinctly identified within complex matrices such as wine, beverages, urine, and lake water. This innovative drug detection technology offers several advantages, including a simple setup, cost-effectiveness, rapid detection, high sensitivity, and minimal sample pretreatment.
Collapse
Affiliation(s)
- Wei Zhang
- College of Chemistry and Chemical Engineering, Shenyang Normal University, Shenyang 110034, Liaoning, China.
| | - Zhongbao Han
- College of Chemistry and Chemical Engineering, Shenyang Normal University, Shenyang 110034, Liaoning, China.
| | - Zhongyu Zhao
- College of Chemistry and Chemical Engineering, Shenyang Normal University, Shenyang 110034, Liaoning, China.
| | - Jianjun Shi
- College of Chemistry and Chemical Engineering, Shenyang Normal University, Shenyang 110034, Liaoning, China.
| | - Liyan Liu
- College of Chemistry and Chemical Engineering, Shenyang Normal University, Shenyang 110034, Liaoning, China.
| | - Dan Wang
- School of Narcotics Control and Public Order Studies, Criminal Investigation Police University of China, Shenyang 110854, Liaoning, China.
| | - Zhan Yu
- College of Chemistry and Chemical Engineering, Shenyang Normal University, Shenyang 110034, Liaoning, China.
| |
Collapse
|
2
|
Aderorho R, Chouinard CD. Improved separation of fentanyl isomers using metal cation adducts and high-resolution ion mobility-mass spectrometry. Drug Test Anal 2024; 16:369-379. [PMID: 37491787 DOI: 10.1002/dta.3550] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 06/30/2023] [Accepted: 07/08/2023] [Indexed: 07/27/2023]
Abstract
Fentanyl is a potent synthetic opioid that has attracted significant attention due to its illegal production and distribution, resulting in misuse, overdose, and fatalities. Because numerous fentanyl analogs, including structural isomers, with different potency have been discovered in the field, there is a critical need to continue developing analytical methodologies capable of accurate identification in forensic and clinical laboratories. This study aimed to develop a rapid method for detecting and separating fentanyl isomers based on ion mobility-mass spectrometry (IM-MS), where IM separates gas-phase ions based on differences in their size, shape, and charge. Several strategies for improved differentiation were implemented, including using unconventional cation adducts (e.g., alkali and transition metals) and data post-processing by high-resolution demultiplexing. A collection of collision cross section (CCS) values for the various metal ion adducts was gathered, which can be used to improve confidence of identification in future samples. Notable examples, such as [M + Cu]+ and [M + Ag]+ adducts, contributed to significant improvement of resolution between isomers. Furthermore, the addition of high-resolution post-processing provided resolving power of >150, which constitutes a significant increase in comparison with the normal 50-60 obtained with low-resolution drift tube instruments. Collectively, these improved separation strategies allowed for confident detection and subsequent quantitative analysis. The optimized IM-MS method resulted in quantification of fentanyl in human urine with limits of detection and quantification of 13 pg/mL and 40 pg/mL, respectively.
Collapse
Affiliation(s)
- Ralph Aderorho
- Department of Chemistry, Clemson University, Clemson, SC, USA
| | | |
Collapse
|
3
|
Palmquist KB, Truver MT, Shoff EN, Krotulski AJ, Swortwood MJ. Review of analytical methods for screening and quantification of fentanyl analogs and novel synthetic opioids in biological specimens. J Forensic Sci 2023; 68:1643-1661. [PMID: 37221651 DOI: 10.1111/1556-4029.15282] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/24/2023] [Accepted: 05/05/2023] [Indexed: 05/25/2023]
Abstract
Fentanyl, fentanyl analogs, and other novel synthetic opioids (NSO), including nitazene analogs, prevail in forensic toxicology casework. Analytical methods for identifying these drugs in biological specimens need to be robust, sensitive, and specific. Isomers, new analogs, and slight differences in structural modifications necessitate the use of high-resolution mass spectrometry (HRMS), especially as a non-targeted screening method designed to detect newly emerging drugs. Traditional forensic toxicology workflows, such as immunoassay and gas chromatography mass spectrometry (GC-MS), are generally not sensitive enough for detection of NSOs due to observed low (sub-μg/L) concentrations. For this review, the authors tabulated, reviewed, and summarized analytical methods from 2010-2022 for screening and quantification of fentanyl analogs and other NSOs in biological specimens using a variety of different instruments and sample preparation approaches. Limits of detection or quantification for 105 methods were included and compared to published standards and guidelines for suggested scope and sensitivity in forensic toxicology casework. Methods were summarized by instrument for screening and quantitative methods for fentanyl analogs and for nitazenes and other NSO. Toxicological testing for fentanyl analogs and NSOs is increasingly and most commonly being conducted using a variety of liquid chromatography mass spectrometry (LC-MS)-based techniques. Most of the recent analytical methods reviewed exhibited limits of detection well below 1 μg/L to detect low concentrations of increasingly potent drugs. In addition, it was observed that most newly developed methods are now using smaller sample volumes which is achievable due to the sensitivity increase gained by new technology and new instrumentation.
Collapse
Affiliation(s)
| | - Michael T Truver
- Forensic Toxicology Laboratory, Department of Pathology, Immunology and Laboratory Medicine, University of Florida College of Medicine, Gainesville, Florida, USA
| | - Elisa N Shoff
- Miami-Dade Medical Examiner Department, Miami, Florida, USA
| | - Alex J Krotulski
- Center for Forensic Science Research and Education, Fredric Rieders Family Foundation, Willow Grove, Pennsylvania, USA
| | - Madeleine J Swortwood
- Department of Forensic Science, Sam Houston State University, Huntsville, Texas, USA
| |
Collapse
|
4
|
Shao W, Zeng Z, Star A. An Ultrasensitive Norfentanyl Sensor Based on a Carbon Nanotube-Based Field-Effect Transistor for the Detection of Fentanyl Exposure. ACS APPLIED MATERIALS & INTERFACES 2023; 15:37784-37793. [PMID: 37523478 PMCID: PMC10416144 DOI: 10.1021/acsami.3c05958] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 07/14/2023] [Indexed: 08/02/2023]
Abstract
The opioid crisis is a worldwide public health crisis that has affected millions of people. In recent years, synthetic opioids, primarily illicit fentanyl, have become the primary driver of overdose deaths. There is a great need for a highly sensitive, portable, and inexpensive analytical tool that can quickly indicate the presence and relative threat of fentanyl. In this work, we develop a semiconductor enriched (sc-) single-walled carbon nanotube (SWCNT)-based field-effect transistor (FET) biosensor functionalized with norfentanyl antibodies for the sensitive detection of norfentanyl, the primary inactive metabolite of fentanyl, in urine samples. Different sensor configurations were explored in order to obtain the most optimized sensing results. Moreover, by employing the "reduced" antibody, we achieved orientated immobilization of the norfentanyl antibody and thus brought the antigen-antibody interaction closer to the sensor surface, further improving the sensitivity. The reported norfentanyl biosensors have a limit of detection in the fg/mL region in both calibration samples and synthetic urine samples, showing ultrasensitivity and high reliability.
Collapse
Affiliation(s)
- Wenting Shao
- Department
of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Zidao Zeng
- Department
of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Alexander Star
- Department
of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
- Department
of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| |
Collapse
|
5
|
González-Hernández J, Moya-Alvarado G, Alvarado-Gámez AL, Urcuyo R, Barquero-Quirós M, Arcos-Martínez MJ. Electrochemical biosensor for quantitative determination of fentanyl based on immobilized cytochrome c on multi-walled carbon nanotubes modified screen-printed carbon electrodes. Mikrochim Acta 2022; 189:483. [DOI: 10.1007/s00604-022-05578-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 11/14/2022] [Indexed: 12/02/2022]
|
6
|
Valdez CA, Leif RN, Corzett TH, Dreyer ML. Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS. PLoS One 2022; 17:e0275931. [PMID: 36322521 PMCID: PMC9629642 DOI: 10.1371/journal.pone.0275931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Accepted: 09/27/2022] [Indexed: 11/06/2022] Open
Abstract
Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method's LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method's main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.
Collapse
Affiliation(s)
- Carlos A. Valdez
- Forensic Science Center, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- * E-mail:
| | - Roald N. Leif
- Forensic Science Center, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
| | - Todd H. Corzett
- Forensic Science Center, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- Biosciences and Biotechnology Division, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
| | - Mark L. Dreyer
- Forensic Science Center, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
- Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, CA, United States of America
| |
Collapse
|
7
|
Smart K, Reyes K, Wilder K, Acree Jr WE, Verbeck GF, Golden TD. Ionic liquids as stationary phases for the gas chromatographic separation of fentanyl analogues. Forensic Chem 2022. [DOI: 10.1016/j.forc.2022.100452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
8
|
Zhao Q, Wang R, Liang C, Chen Y, Sheng Z, Xu Z, Zhang Y. Extension of the Temporal Window for the Determination of Alpha-Methylthiofentanyl and Thiofentanyl in Rat Urine by Monitoring the Metabolite Norfentanyl Using Online Solid-Phase Extraction (SPE) Coupled with Ultra-High Performance Liquid Chromatography–Tandem Mass Spectrometry (UHPLC–MS/MS). ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2087229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Qingjia Zhao
- State Key Laboratory of New Drug and Pharmaceutical Process, China State Institute of Pharmaceutical Industry, Shanghai, China
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | - Rong Wang
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | - Chen Liang
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | - Yao Chen
- State Key Laboratory of New Drug and Pharmaceutical Process, China State Institute of Pharmaceutical Industry, Shanghai, China
- Shanghai Professional and Technical Service Center for Biological Material Drug-ability Evaluation, Shanghai, China
| | - Zhenhai Sheng
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| | - Zhiru Xu
- State Key Laboratory of New Drug and Pharmaceutical Process, China State Institute of Pharmaceutical Industry, Shanghai, China
- Shanghai Professional and Technical Service Center for Biological Material Drug-ability Evaluation, Shanghai, China
| | - Yurong Zhang
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai Institute of Forensic Science, Shanghai, China
| |
Collapse
|
9
|
Ares-Fuentes AM, Lorenzo RA, Fernández P, Fernández AM, Furton KG, Kabir A, Carro AM. Determination of synthetic opioids in oral fluid samples using fabric phase sorptive extraction and gas chromatography-mass spectrometry. J Chromatogr A 2022; 1663:462768. [PMID: 34974368 DOI: 10.1016/j.chroma.2021.462768] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 12/15/2021] [Accepted: 12/20/2021] [Indexed: 01/10/2023]
Abstract
New psychoactive substances (NPS) continue to emerge in the drug market every year, becoming a global threat to public health and safety. These compounds are mostly synthetic cannabinoids and designer cathinones. However, synthetic opioids have appeared on the recreational drug markets in recent years, particularly fentanyl and its derivatives ("fentanyls"). Fentanyl and its analogs are related to harmful intoxications and an increase in opioid-related mortality in many countries, such as in the United States and Europe in the last years. Taking the drug related global crisis into consideration, this work developed and validated an effective and sensitive method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 11 fentanyl analogs in oral fluid samples. The extraction was carried out using a sol-gel Carbowax 20 M sorbent immobilized on 100% cellulose fabric substrate and using ethyl acetate as the desorption solvent. The limits of detection (LODs) and quantification (LOQs) ranged from 1 to 15 ng mL-1 and 5 to 50 ng mL-1, respectively. Intra-day and inter-day precision were found within 8.2% and 8.6%, respectively, while accuracy ranged from -5.5 to 9.1%, in accordance with the established criteria. The absolute recovery values were in the range of 94.5%-109.1%. The validated method demonstrated its great potential to detect and quantify fentanyl analogs in possible forensic work and off-site analysis in road traffic cases.
Collapse
Affiliation(s)
- Ana M Ares-Fuentes
- Department of Analytical Chemistry, Nutrición y Bromatología, Faculty of Chemistry and Health Research, Institute of Santiago de Compostela (IDIS), University of Santiago de Compostela, Avda de las Ciencias S/N, Santiago de Compostela E-15782, Spain
| | - Rosa A Lorenzo
- Department of Analytical Chemistry, Nutrición y Bromatología, Faculty of Chemistry and Health Research, Institute of Santiago de Compostela (IDIS), University of Santiago de Compostela, Avda de las Ciencias S/N, Santiago de Compostela E-15782, Spain
| | - Purificación Fernández
- Institute of Legal Medicine, Forensic Toxicology Service, University of Santiago de Compostela, Santiago de Compostela E-15782, Spain
| | | | - Kenneth G Furton
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, Miami, FL 33199, USA
| | - Abuzar Kabir
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, Miami, FL 33199, USA; Department of Pharmacy, Faculty of Allied Health Sciences, Daffodil International University, Dhaka 1207, Bangladesh
| | - Antonia M Carro
- Department of Analytical Chemistry, Nutrición y Bromatología, Faculty of Chemistry and Health Research, Institute of Santiago de Compostela (IDIS), University of Santiago de Compostela, Avda de las Ciencias S/N, Santiago de Compostela E-15782, Spain; Department of Analytical Chemistry, Nutrición y Bromatología, Faculty of Chemistry. Health Research, Institute of Santiago de Compostela (IDIS). Instituto de Materiais (iMATUS). University of Santiago de Compostela, Avda de las Ciencias S/N, Santiago de Compostela E-15782, Spain.
| |
Collapse
|
10
|
Guo X, Shang Y, Lv Y, Bai H, Ma Q. Suspect Screening of Fentanyl Analogs Using Matrix-Assisted Ionization and a Miniature Mass Spectrometer with a Custom Expandable Mass Spectral Library. Anal Chem 2021; 93:10152-10159. [PMID: 34254788 DOI: 10.1021/acs.analchem.1c01117] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The reliable identification of fentanyl and its analogs is of great significance for public security. However, with the growing prevalence of fentanyl compounds, current analytical strategies cannot fully meet the need for fast and high-throughput detection. In this study, a simple, rapid, and on-site analytical protocol was developed based on a miniature mass spectrometer. A dramatically simplified workflow was implemented using matrix-assisted ionization, bypassing complex sample pretreatment and chromatographic separation. The tandem mass spectrometry (MS/MS) capability afforded by the miniature ion trap mass spectrometer facilitated the investigation of fragmentation patterns for 49 fentanyl analogs during collision-induced dissociation, revealing valuable information on marker fragment ions and characteristic neutral loss. Calculations on Laplacian bond order values further verified the mass spectrometric behavior. A computation-assisted expandable mass spectral library was constructed in-house for fentanyl compounds. Smart suspect screening was carried out based on the full-scan MS and MS/MS data. The present study demonstrates an appealing potential for forensic applications, enabling streamlined screening for the presence of illicit fentanyl compounds at the point of seizures of suspect samples.
Collapse
Affiliation(s)
- Xiangyu Guo
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Yuhan Shang
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Yueguang Lv
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China.,School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hua Bai
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Qiang Ma
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| |
Collapse
|
11
|
Valdez CA. Gas Chromatography-Mass Spectrometry Analysis of Synthetic Opioids Belonging to the Fentanyl Class: A Review. Crit Rev Anal Chem 2021; 52:1938-1968. [PMID: 34053394 DOI: 10.1080/10408347.2021.1927668] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
The rising number of deaths caused by fentanyl overdosing in the US due to the overwhelming illicit use of this synthetic opioid has started a global campaign to develop efficient ways to control its production and distribution as well as discovering efficient antidotes to mitigate its lethal effects. Another important vein of focused research established by various agencies lies in the development of efficient and practical protocols for the detection of this opioid and analogs thereof in various matrices, whether environmental or biological in nature, particularly in the field of gas chromatography-mass spectrometry (GC-MS). The following review will cover the literature dealing with the detection and identification of synthetic opioids belonging to the fentanyl class by GC-MS means and hyphenated versions of the technique. Detailed descriptions will be given for the GC-MS methods employed for the analysis of the opioid, starting with the nature of the extraction protocol employed prior to analysis to the actual findings presented by the cited reports. Great effort has gone into describing the methods involved in each paper in a detailed manner and these have been compiled by year in tables at the end of each section for the reader's convenience. Lastly, the review will end with concluding remarks about the state of GC-MS analysis with regards to these powerful opioids and what lies ahead for this analytical field.
Collapse
Affiliation(s)
- Carlos A Valdez
- Lawrence Livermore National Laboratory, Forensic Science Center, Livermore, California, USA.,Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California, USA.,Nuclear and Chemical Sciences Division, Lawrence Livermore National Laboratory, Livermore, California, USA
| |
Collapse
|
12
|
Li L, Yu X, Lyu L, Duan H, Chen Y, Bian J, Xu Z, Liu L, Zhang Y. Determination of Fentanyl, Alpha-Methylfentanyl, Beta-Hydroxyfentanyl, and the Metabolite Norfentanyl in Rat Urine by LC-MS/MS. J Anal Toxicol 2021; 46:421-431. [PMID: 33647104 DOI: 10.1093/jat/bkab021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 02/24/2021] [Accepted: 02/27/2021] [Indexed: 01/20/2023] Open
Abstract
Fentanyl and its analogs are potent synthetic opioids with a high potential for abuse and dependence. They have become major contributors to opioid deaths. This study aimed to determine whether the metabolites of fentanyl, alpha-methylfentanyl and beta-hydroxyfentanyl, excreted in the urine, can demonstrate historical drug exposure. Fentanyl is primarily metabolized via CYP3A4 into norfentanyl, although there is little research on its metabolism into alpha-methylfentanyl and beta-hydroxyfentanyl. We conducted in vitro experiments with human liver microsomes (HLM) and rat liver microsomes (RLM) to elucidate the major metabolic pathways of alpha-methylfentanyl and beta-hydroxyfentanyl using UHPLC coupled with mass spectrometry. The results showed that both alpha-methylfentanyl and beta-hydroxyfentanyl were predominantly metabolized into norfentanyl in HLM and RLM. Urine samples were collected at different intervals from 0 h to 72 h after intravenous administration of alpha-methylfentanyl and beta-hydroxyfentanyl (20 μg/kg) to Sprague-Dawley rats. We prepared the samples by liquid-liquid extraction, and the internal standard (IS) was cariprazine. A sensitive, rapid LC-MS/MS method was developed and validated to determine four analytes in the urine. The lower limit of qualification (LLOQ) in urine was 2 pg/ml for fentanyl, 5 pg/ml for alpha-methylfentanyl, 10 pg/ml for beta-hydroxyfentanyl, and 40 pg/ml for norfentanyl. The analytical range was 0.002-2 ng/ml for fentanyl, 0.005-5 ng/ml for alpha-methylfentanyl, 0.01-10 ng/ml for beta-hydroxyfentany and 0.04-40 ng/ml for norfentanyl. All analytes demonstrated good linearity (R2 > 0.99). The extraction recoveries were in the 67.8%-92.1% range, and the IS-normalized matrix effects were between 55.5%-74.0% (CV < 15%). Our data indicated that norfentanyl has a higher concentration in rat urine and was detectable for at least three days after exposure to these compounds. This developed method may be useful in various fields, including forensic analysis, workplace drug testing, and monitoring drug abuse.
Collapse
Affiliation(s)
- Lu Li
- College of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, Shanghai 201620, China
| | - Xuejiao Yu
- State Key Laboratory of New Drug and Pharmaceutical process, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry, Shanghai 200437, China
| | - Lihong Lyu
- State Key Laboratory of New Drug and Pharmaceutical process, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry, Shanghai 200437, China
| | - Hongbin Duan
- State Key Laboratory of New Drug and Pharmaceutical process, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry, Shanghai 200437, China
| | - Yao Chen
- State Key Laboratory of New Drug and Pharmaceutical process, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry, Shanghai 200437, China
| | - Jing Bian
- State Key Laboratory of New Drug and Pharmaceutical process, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry, Shanghai 200437, China
| | - Zhiru Xu
- State Key Laboratory of New Drug and Pharmaceutical process, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry, Shanghai 200437, China
| | - Li Liu
- State Key Laboratory of New Drug and Pharmaceutical process, Shanghai Institute of Pharmaceutical Industry, China State Institute of Pharmaceutical Industry, Shanghai 200437, China
| | - Yurong Zhang
- Shanghai Key Laboratory of Crime Scene Evidence, Shanghai 200437, China
| |
Collapse
|
13
|
Roberson ZR, Goodpaster JV. Optimization of the qualitative and quantitative analysis of cocaine and other drugs of abuse via gas chromatography - Vacuum ultraviolet spectrophotometry (GC - VUV). Talanta 2021; 222:121461. [PMID: 33167202 DOI: 10.1016/j.talanta.2020.121461] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 07/23/2020] [Accepted: 07/24/2020] [Indexed: 12/21/2022]
Abstract
Gas Chromatography-Vacuum UV Spectroscopy (GC-VUV) has seen increased attention in many areas, however, a statistical optimization of VUV method parameters has not been published. This article presents the first statistical optimization of parameters influencing analytes such as cocaine in the VUV flow-cell. Flow-cell temperature, make-up gas pressure, and carrier gas flow rate from the GC were examined and optimized for the detection of controlled substances. The accuracy, precision, linearity, and optimized detection limits for drugs such as cocaine (98.5%, 1.2%, 0.9998, 1.5 ng), heroin (99.3%, 0.94%, 0.9998, 2.0 ng), and fentanyl (98.5%, 1.7%, 0.9752, 9.7 ng) are reported. In general, the limits of detection for cocaine, heroin, fentanyl, and methamphetamine after optimization were comparable to gas chromatography-mass spectrometry (GC-MS) in "scan mode", which had detection limits of 1.1-38 ng on column. The VUV absorption spectra of cocaine, PCP, lorazepam, and HU-210 are also reported. And three samples of "real world" cocaine are analyzed to demonstrate applicability to forensic drug analysis.
Collapse
Affiliation(s)
- Zackery R Roberson
- Department of Chemistry and Chemical Biology, Indiana University Purdue University Indianapolis, 402 North Blackford St., LD326, Indianapolis, IN, 46202, United States
| | - John V Goodpaster
- Department of Chemistry and Chemical Biology, Indiana University Purdue University Indianapolis, 402 North Blackford St., LD326, Indianapolis, IN, 46202, United States; Forensic and Investigative Sciences Program, Indiana University Purdue University Indianapolis, 402 North Blackford St., LD326, Indianapolis, IN, 46202, United States.
| |
Collapse
|
14
|
Gilbert N, Mewis RE, Sutcliffe OB. Classification of fentanyl analogues through principal component analysis (PCA) and hierarchical clustering of GC–MS data. Forensic Chem 2020. [DOI: 10.1016/j.forc.2020.100287] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
15
|
Borden SA, Palaty J, Termopoli V, Famiglini G, Cappiello A, Gill CG, Palma P. MASS SPECTROMETRY ANALYSIS OF DRUGS OF ABUSE: CHALLENGES AND EMERGING STRATEGIES. MASS SPECTROMETRY REVIEWS 2020; 39:703-744. [PMID: 32048319 DOI: 10.1002/mas.21624] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Accepted: 01/22/2020] [Indexed: 06/10/2023]
Abstract
Mass spectrometry has been the "gold standard" for drugs of abuse (DoA) analysis for many decades because of the selectivity and sensitivity it affords. Recent progress in all aspects of mass spectrometry has seen significant developments in the field of DoA analysis. Mass spectrometry is particularly well suited to address the rapidly proliferating number of very high potency, novel psychoactive substances that are causing an alarming number of fatalities worldwide. This review surveys advancements in the areas of sample preparation, gas and liquid chromatography-mass spectrometry, as well as the rapidly emerging field of ambient ionization mass spectrometry. We have predominantly targeted literature progress over the past ten years and present our outlook for the future. © 2020 Periodicals, Inc. Mass Spec Rev.
Collapse
Affiliation(s)
- Scott A Borden
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, V8P 5C2, Canada
| | - Jan Palaty
- LifeLabs Medical Laboratories, Burnaby, BC, V3W 1H8, Canada
| | - Veronica Termopoli
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Giorgio Famiglini
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Achille Cappiello
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Chris G Gill
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, V8P 5C2, Canada
- Department of Chemistry, Simon Fraser University, Burnaby, BC, V5A 1S6, Canada
- Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, WA, 98195
| | - Pierangela Palma
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| |
Collapse
|
16
|
Miniaturized extraction method for analysis of synthetic opioids in urine by microextraction with packed sorbent and liquid chromatography—tandem mass spectrometry. J Chromatogr A 2020; 1624:461241. [DOI: 10.1016/j.chroma.2020.461241] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Revised: 05/12/2020] [Accepted: 05/14/2020] [Indexed: 01/28/2023]
|
17
|
Yadav SK, Nagar DP, Bhattacharya R. Effect of fentanyl and its three novel analogues on biochemical, oxidative, histological, and neuroadaptive markers after sub-acute exposure in mice. Life Sci 2020; 246:117400. [PMID: 32032645 DOI: 10.1016/j.lfs.2020.117400] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 01/19/2020] [Accepted: 02/02/2020] [Indexed: 10/25/2022]
Abstract
AIMS Comparative sub-acute toxicity, including tolerance and dependence potential of fentanyl and its three novel and potent analogues was determined in mice. MAIN METHODS Comparative sub-acute (21 d, intraperitoneal; 1/10 LD50) toxicity of fentanyl and its three novel analogues viz., N-(1-(2-phenoxyethyl)-4-piperidinyl) propionanilide (2), N-isopropyl-3-(4-(N-phenylpropionamido)piperidin-1-yl)propanamide (5), and N-t-butyl-3-(4-(N-phenylpropionamido)piperidin-1-yl)propanamide (6) was determined in mice. Animals were observed for additional seven days to assess the recovery. The brain, liver and kidney toxicity was assessed on the basis of various biochemical, oxidative, histological, and neuroadaptive markers. The expression levels of key neuronal markers associated with drug tolerance and dependence were investigated by western blot and immunohistochemistry. KEY FINDINGS Fentanyl and its analogues caused abnormal levels of liver and kidney specific biomarkers in plasma. Brain malondialdehyde (MDA) levels were raised by all the treatments and kidney MDA level by analogue 6 (21 d). Reduced glutathione levels in brain, liver, and kidney were diminished by all the treatments (21 & 28 d) and a significant change in the levels of antioxidant enzymes was also produced mainly after 21 d. The deleterious effects of fentanyl and its analogues were further substantiated by corresponding histopathological changes in brain, liver and kidney (21 & 28 d). These compounds were also found to produce neuroadaptive changes as evidenced by the increased expression levels of c-Fos, glucocorticoid receptor, N-methyl-d-aspartate receptor1 and μ-opioid receptor (21 & 28 d). SIGNIFICANCE Three novel analogues of fentanyl were envisaged to have alternative therapeutic potentials. However, their comparative sub-acute toxicity revealed undesirable side effects, thereby masking their therapeutic ability.
Collapse
Affiliation(s)
- Shiv Kumar Yadav
- Division of Pharmacology and Toxicology, Defence Research and Development Establishment, Jhansi Road, Gwalior 474 002, M.P., India
| | - D P Nagar
- Division of Pharmacology and Toxicology, Defence Research and Development Establishment, Jhansi Road, Gwalior 474 002, M.P., India
| | - Rahul Bhattacharya
- Division of Pharmacology and Toxicology, Defence Research and Development Establishment, Jhansi Road, Gwalior 474 002, M.P., India.
| |
Collapse
|
18
|
Grimes N, Vuppala S, Ayodeji I, Donovan J, Evans-Nguyen T. Enabling Field Asymmetric Ion Mobility Spectrometry Separation of Fentanyl-Related Compounds Using Controlled Humidity. Anal Chem 2020; 92:2917-2921. [PMID: 31976655 DOI: 10.1021/acs.analchem.9b02997] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Due to the widespread abuse of opioids in recent years, the development of quick and reliable methods for analyzing compounds such as fentanyl and its derivatives is increasingly important. Ahead of online mass spectrometric analysis, field asymmetric ion mobility spectrometry (FAIMS) has previously been used for rapid ion prefiltering and demonstrated significantly improved peak capacity with the addition of vapor modifiers to the carrier gas. The application of FAIMS-mass spectrometry (MS) in the analysis of fentanyl and related compounds is presented herein with the use of a water vapor modifier. The inclusion of the water vapor modifier to the FAIMS methodology is made more robust with the incorporation of a humidity sensor. A dramatic improvement in the separation of fentanyl, alfentanil, 4-aminophenyl-1-phenethylpiperidine (4-ANPP), norfentanyl, and heroin has been achieved, and the ability to distinguish the isobars in a mixture, alfentanil and ortho-isopropyl furanyl fentanyl, is demonstrated without lengthy chromatography.
Collapse
Affiliation(s)
- Nathan Grimes
- University of South Florida , Tampa , Florida 33620 , United States
| | - Sinduri Vuppala
- University of South Florida , Tampa , Florida 33620 , United States
| | - Ifeoluwa Ayodeji
- University of South Florida , Tampa , Florida 33620 , United States
| | - Joanne Donovan
- University of South Florida , Tampa , Florida 33620 , United States
| | | |
Collapse
|
19
|
Gilbert N, Antonides LH, Schofield CJ, Costello A, Kilkelly B, Cain AR, Dalziel PR, Horner K, Mewis RE, Sutcliffe OB. Hitting the Jackpot – development of gas chromatography–mass spectrometry (GC–MS) and other rapid screening methods for the analysis of 18 fentanyl‐derived synthetic opioids. Drug Test Anal 2020; 12:798-811. [DOI: 10.1002/dta.2771] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 01/20/2020] [Accepted: 01/21/2020] [Indexed: 01/03/2023]
Affiliation(s)
- Nicolas Gilbert
- Faculty of Science and Engineering, Department of Natural SciencesManchester Metropolitan University Manchester UK
- MANchester DRug Analysis & Knowledge Exchange (MANDRAKE)Manchester Metropolitan University Manchester UK
| | - Lysbeth H. Antonides
- Faculty of Science and Engineering, Department of Natural SciencesManchester Metropolitan University Manchester UK
- Present address: Leverhulme Research Centre for Forensic ScienceUniversity of Dundee Dundee DD1 5EH, UK
| | - Christopher J. Schofield
- MANchester DRug Analysis & Knowledge Exchange (MANDRAKE)Manchester Metropolitan University Manchester UK
- Greater Manchester Police, Openshaw Complex, Manchester UK
| | - Andrew Costello
- MANchester DRug Analysis & Knowledge Exchange (MANDRAKE)Manchester Metropolitan University Manchester UK
- Greater Manchester Police, Openshaw Complex, Manchester UK
| | - Brenda Kilkelly
- Faculty of Science and Engineering, Department of Natural SciencesManchester Metropolitan University Manchester UK
| | - Alan R. Cain
- MANchester DRug Analysis & Knowledge Exchange (MANDRAKE)Manchester Metropolitan University Manchester UK
- Security & Business ContinuityManchester Metropolitan University Manchester UK
- Present address: NHS Manchester CCG Parkway 3, Parkway Business Centre, Princess Road Manchester M14 7LU UK
| | - Paula R.V. Dalziel
- Residential ServicesManchester Metropolitan University Business School Manchester UK
| | - Karen Horner
- Residential ServicesManchester Metropolitan University Business School Manchester UK
| | - Ryan E. Mewis
- Faculty of Science and Engineering, Department of Natural SciencesManchester Metropolitan University Manchester UK
| | - Oliver B. Sutcliffe
- Faculty of Science and Engineering, Department of Natural SciencesManchester Metropolitan University Manchester UK
- MANchester DRug Analysis & Knowledge Exchange (MANDRAKE)Manchester Metropolitan University Manchester UK
| |
Collapse
|
20
|
Angi C, Lurie IS, Marginean I. Analysis of fentanyl derivatives by ultra high performance liquid chromatography with diode array ultraviolet and single quadrupole mass spectrometric detection. J Sep Sci 2019; 42:1686-1694. [DOI: 10.1002/jssc.201801098] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 02/16/2019] [Accepted: 02/17/2019] [Indexed: 11/07/2022]
Affiliation(s)
- Carolyn Angi
- George Washington University Department of Forensic Sciences NW Washington, DC USA
| | - Ira S. Lurie
- George Washington University Department of Forensic Sciences NW Washington, DC USA
| | - Ioan Marginean
- George Washington University Department of Forensic Sciences NW Washington, DC USA
| |
Collapse
|
21
|
Palmquist KB, Swortwood MJ. Data-independent screening method for 14 fentanyl analogs in whole blood and oral fluid using LC-QTOF-MS. Forensic Sci Int 2019; 297:189-197. [DOI: 10.1016/j.forsciint.2019.02.006] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 01/28/2019] [Accepted: 02/04/2019] [Indexed: 11/28/2022]
|
22
|
Roda G, Faggiani F, Bolchi C, Pallavicini M, Dei Cas M. Ten Years of Fentanyl-like Drugs: a Technical-analytical Review. ANAL SCI 2019; 35:479-491. [PMID: 30686797 DOI: 10.2116/analsci.18r004] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Synthetic opioids, such as fentanyl and its analogues, are a new public health warning. Clandestine laboratories produce drug analogues at a faster rate than these compounds can be controlled or scheduled by drug agencies. Detection requires specific testing and clinicians may be confronted with a sequence of severe issues concerning the diagnosis and management of these contemporary opioid overdoses. This paper deals with methods for biological sample treatment, as well as the methodologies of analysis that have been reported, in the last decade, in the field of fentanyl-like compounds. From this analysis, it emerges that the gold standard for the identification and quantification of 4-anilinopiperidines is LC-MS/MS, coupled with liquid-liquid or solid-phase extraction. In the end, the return to the scene of illicit fentanyls can be considered as a critical problem that can be tackled only with a global multidisciplinary approach.
Collapse
Affiliation(s)
- Gabriella Roda
- Department of Pharmaceutical Sciences, University of Milan
| | | | | | | | | |
Collapse
|
23
|
Strayer K, Antonides HM, Juhascik MP, Daniulaityte R, Sizemore IE. LC-MS/MS-Based Method for the Multiplex Detection of 24 Fentanyl Analogues and Metabolites in Whole Blood at Sub ng mL -1 Concentrations. ACS OMEGA 2018; 3:514-523. [PMID: 29399650 PMCID: PMC5793031 DOI: 10.1021/acsomega.7b01536] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Accepted: 01/03/2018] [Indexed: 05/05/2023]
Abstract
The United States and numerous other countries worldwide are currently experiencing a public health crisis due to the abuse of illicitly manufactured fentanyl (IMF) and its analogues. This manuscript describes the development of a liquid chromatography-tandem mass spectrometry-based method for the multiplex detection of N = 24 IMF analogues and metabolites in whole blood at concentrations as low as 0.1-0.5 ng mL-1. These available IMFs were fentanyl, norfentanyl, furanyl norfentanyl, remifentanil acid, butyryl norfentanyl, remifentanil, acetyl fentanyl, alfentanil, AH-7921, U-47700, acetyl fentanyl 4-methylphenethyl, acrylfentanyl, para-methoxyfentanyl, despropionyl fentanyl (4-ANPP), furanyl fentanyl, despropionyl para-fluorofentanyl, carfentanil, (±)-cis-3-methyl fentanyl, butyryl fentanyl, isobutyryl fentanyl, sufentanil, valeryl fentanyl, para-fluorobutyryl fentanyl, and para-fluoroisobutyryl fentanyl. Most IMF analogues (N = 22) could be easily distinguished from one another; the isomeric forms butyryl/isobutyryl fentanyl and para-fluorobutyryl/para-fluoroisobutyryl fentanyl could not be differentiated. N = 13 of these IMF analogues were quantified for illustrative purposes, and their forensic quality control standards were also validated for limit of detection (0.017-0.056 ng mL-1), limit of quantitation (0.100-0.500 ng mL-1), selectivity/sensitivity, ionization suppression/enhancement (87-118%), process efficiency (60-95%), recovery (64-97%), bias (<20%), and precision (>80%). This flexible, time- and cost-efficient method was successfully implemented at the Montgomery County Coroner's Office/Miami Valley Regional Crime Laboratory in Dayton, Ohio, where it aided in the analysis of N = 725 postmortem blood samples collected from February 2015 to November 2016.
Collapse
Affiliation(s)
- Kraig
E. Strayer
- Department
of Chemistry, Wright State University, 3640 Colonel Glenn Hwy, Dayton, Ohio 45435, United States
- Montgomery
County Coroner’s Office, 361 W 3rd Street, Dayton, Ohio 45402, United States
| | - Heather M. Antonides
- Montgomery
County Coroner’s Office, 361 W 3rd Street, Dayton, Ohio 45402, United States
| | - Matthew P. Juhascik
- Montgomery
County Coroner’s Office, 361 W 3rd Street, Dayton, Ohio 45402, United States
| | - Raminta Daniulaityte
- Center
for Interventions, Treatment, and Addictions Research, Department
of Population and Public Health Sciences, Boonshoft School of Medicine, Wright State University, 3171 Research Boulevard Suite 234, Kettering, Ohio 45420, United States
| | - Ioana E. Sizemore
- Department
of Chemistry, Wright State University, 3640 Colonel Glenn Hwy, Dayton, Ohio 45435, United States
| |
Collapse
|
24
|
Melent’ev AB, Kataev SS, Dvorskaya ON. Identification and analytical properties of acetyl fentanyl metabolites. JOURNAL OF ANALYTICAL CHEMISTRY 2015. [DOI: 10.1134/s1061934815020124] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
25
|
Gardner MA, Sampsel S, Jenkins WW, Owens JE. Analysis of fentanyl in urine by DLLME-GC-MS. J Anal Toxicol 2014; 39:118-25. [PMID: 25492522 DOI: 10.1093/jat/bku136] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Fentanyl is a synthetic narcotic anesthetic ∼80-100 times more potent than morphine. Owing to the potential for its abuse, the drug may be included in a forensic toxicology work-up, which requires fast, precise and accurate measurements. Here, the stability of fentanyl was assessed when stored at three different temperatures (-20, 4 and 25°C) in synthetic urine. Stability at those three temperatures was demonstrated over 12 weeks upon analysis by gas chromatography-mass spectrometry with a deuterated internal standard (fentanyl-D5) utilizing three different extraction techniques: liquid-liquid extraction (LLE), solid-phase extraction and dispersed liquid-liquid microextraction (DLLME). The DLLME method was then optimized before use in the analysis of fentanyl in urine samples obtained from autopsy cases at the El Paso County Coroner's Office. Accuracy of the DLLME method was assessed by completing spike and recovery studies at three different fortification levels (10, 100 and 250 ng/mL) with excellent recovery (89.9-102.6%). The excellent comparability between DLLME and LLE is demonstrated (Bland-Altman difference plot with a mean difference of 4.9 ng/mL) and the use of this methodology in the analysis of forensically relevant samples is discussed.
Collapse
Affiliation(s)
- Michael A Gardner
- Department of Chemistry and Biochemistry, University of Colorado Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, CO 80918, USA
| | - Sheena Sampsel
- Beth-El College of Nursing and Health Sciences, University of Colorado Colorado Springs, Colorado Springs, CO, USA
| | - Werner W Jenkins
- Department of Chemistry and Biochemistry, University of Colorado Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, CO 80918, USA El Paso County Coroner's Office, Colorado Springs, CO, USA
| | - Janel E Owens
- Department of Chemistry and Biochemistry, University of Colorado Colorado Springs, 1420 Austin Bluffs Parkway, Colorado Springs, CO 80918, USA
| |
Collapse
|
26
|
Mahlke NS, Ziesenitz V, Mikus G, Skopp G. Quantitative low-volume assay for simultaneous determination of fentanyl, norfentanyl, and minor metabolites in human plasma and urine by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Int J Legal Med 2014; 128:771-8. [PMID: 24997532 DOI: 10.1007/s00414-014-1040-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2014] [Accepted: 06/18/2014] [Indexed: 12/15/2022]
Abstract
A rapid and sensitive liquid chromatography/tandem mass spectrometric (LC-MS/MS) method for simultaneous quantification of fentanyl (F), norfentanyl (NF), despropionylfentanyl (DPF), and hydroxynorfentanyl (OHNF) in human plasma and urine specimens has been developed and validated according to international guidelines. Analytes were extracted from 250-μL plasma or urine by liquid-liquid extraction. OHNF in urine affords a second extraction step and analysis with a different column. Calibration curves in plasma were linear from 0.05-10 ng/mL for F, 0.07-0.5 ng/mL for NF, 0.02-1.0 ng/ml for DPF, and 0.67-3.0 ng/mL for OHNF; in urine, from 0.09-10.0, 0.17-50, 0.08-1.0, and 1.0-5.0 ng/mL for F, NF, DPF, and OHNF, respectively. Analytical bias and intra- and inter-assay imprecision were within ± 15 % of target, except for OHNF in plasma and DPF in urine at the respective lower quality control level. All analytes were stable in processed samples when stored for 24 h at room temperature. Recoveries and process efficiencies were above 82.9 and 75.1 % for all analytes in plasma and urine. The low level of DPF in plasma indicated with a matrix effect of 71.3 % moderate ion suppression, all other analytes in plasma and urine showed no matrix effects. The lower limit of quantification (LOQ) in plasma was 0.05, 0.07, 0.02 and 0.67 ng/mL for F, NF, DPF, and OHNF, respectively. In urine, the LOQ of F, NF, DPF, and OHNF were 0.09, 0.17, 0.08, and 1.28 ng/mL, respectively. This assay has been applied to human specimens collected during a clinical drug-drug interaction study.
Collapse
Affiliation(s)
- Nina Sophia Mahlke
- Institute of Legal Medicine and Traffic Medicine, University Hospital, Voss-Str. 2, 69115, Heidelberg, Germany
| | | | | | | |
Collapse
|
27
|
Shaner RL, Kaplan P, Hamelin EI, Bragg WA, Johnson RC. Comparison of two automated solid phase extractions for the detection of ten fentanyl analogs and metabolites in human urine using liquid chromatography tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 962:52-58. [PMID: 24893271 DOI: 10.1016/j.jchromb.2014.05.025] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2014] [Revised: 03/26/2014] [Accepted: 05/08/2014] [Indexed: 11/25/2022]
Abstract
Two types of automated solid phase extraction (SPE) were assessed for the determination of human exposure to fentanyls in urine. High sensitivity is required to detect these compounds following exposure because of the low dose required for therapeutic effect and the rapid clearance from the body for these compounds. To achieve this sensitivity, two acceptable methods for the detection of human exposure to seven fentanyl analogs and three metabolites were developed using either off-line 96-well plate SPE or on-line SPE. Each system offers different advantages: off-line 96-well plate SPE allows for high throughput analysis of many samples, which is needed for large sample numbers, while on-line SPE removes almost all analyst manipulation of the samples, minimizing the analyst time needed for sample preparation. Both sample preparations were coupled with reversed phase liquid chromatography and isotope dilution tandem mass spectrometry (LC-MS/MS) for analyte detection. For both methods, the resulting precision was within 15%, the accuracy within 25%, and the sensitivity was comparable with the limits of detection ranging from 0.002ng/mL to 0.041ng/mL. Additionally, matrix effects were substantially decreased from previous reports for both extraction protocols. The results of this comparison showed that both methods were acceptable for the detection of exposures to fentanyl analogs and metabolites in urine.
Collapse
Affiliation(s)
- Rebecca L Shaner
- Centers for Disease Control and Prevention, 4770 Buford Highway, MS F44, Atlanta, GA 30341, United States
| | - Pearl Kaplan
- ORISE Fellow, Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Atlanta, GA 30341, United States
| | - Elizabeth I Hamelin
- Centers for Disease Control and Prevention, 4770 Buford Highway, MS F44, Atlanta, GA 30341, United States
| | - William A Bragg
- Centers for Disease Control and Prevention, 4770 Buford Highway, MS F44, Atlanta, GA 30341, United States
| | - Rudolph C Johnson
- Centers for Disease Control and Prevention, 4770 Buford Highway, MS F44, Atlanta, GA 30341, United States.
| |
Collapse
|
28
|
Juebner M, Fietzke M, Beike J, Rothschild MA, Bender K. Assisted suicide by fentanyl intoxication due to excessive transdermal application. Int J Legal Med 2014; 128:949-56. [PMID: 24577713 DOI: 10.1007/s00414-014-0982-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Accepted: 02/14/2014] [Indexed: 10/25/2022]
Abstract
Herein, we report a case of an assisted suicide committed by application of 34 matrix-based fentanyl-containing transdermal therapeutic systems (TTS) with different release rates. The TTS were supplied by the husband but administered by the deceased herself. Besides routine systematic toxicological analysis (STA), the concentrations of fentanyl and norfentanyl were determined in the blood (femoral and heart), urine, stomach content, brain, lung tissue, musculus iliopsoas, liver, kidney, bile and in some of the used TTS by LC-MS/MS. Blood levels of fentanyl were 60.6 μg/L in femoral blood and 94.1 μg/L in heart blood. These concentrations are in good concordance with levels described in cases with accidental or lethal suicidal fentanyl patch application. The organ distribution indicates an influence of post-mortem redistribution. The levels of residual fentanyl in the TTS were also determined. STA furthermore revealed supratherapeutic levels of bromazepam. Thus, the cause of death was a combination of fentanyl and bromazepam intoxication. However, considering the determined levels of fentanyl and norfentanyl in the entire set of specimens and the high toxicity in comparison to bromazepam, fentanyl was the leading toxic noxa.
Collapse
Affiliation(s)
- Martin Juebner
- Institute of Legal Medicine, University Hospital of Cologne, Melatengürtel 60/62, 50823, Cologne, Germany,
| | | | | | | | | |
Collapse
|
29
|
López-Guarnido O, Tabernero MJ, Hernández AF, Rodrigo L, Bermejo AM. Rapid determination of quetiapine in blood by gas chromatography-mass spectrometry. Application to post-mortem cases. J Appl Toxicol 2013; 34:1104-8. [DOI: 10.1002/jat.2944] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2013] [Revised: 09/09/2013] [Accepted: 09/09/2013] [Indexed: 12/11/2022]
Affiliation(s)
- Olga López-Guarnido
- Department of Legal Medicine and Toxicology; University of Granada School of Medicine; Avda. Madrid, 11 18071 Granada Spain
| | - María Jesús Tabernero
- Institute of Legal Medicine, Forensic Toxicology Service, Faculty of Medicine San Francisco; s/n 15782 Santiago de Compostela Spain
| | - Antonio F. Hernández
- Department of Legal Medicine and Toxicology; University of Granada School of Medicine; Avda. Madrid, 11 18071 Granada Spain
| | - Lourdes Rodrigo
- Department of Legal Medicine and Toxicology; University of Granada School of Medicine; Avda. Madrid, 11 18071 Granada Spain
| | - Ana M. Bermejo
- Institute of Legal Medicine, Forensic Toxicology Service, Faculty of Medicine San Francisco; s/n 15782 Santiago de Compostela Spain
| |
Collapse
|
30
|
Abstract
Opioid analgesic misuse has risen significantly over the past two decades, and these drugs now represent the most commonly abused class of prescription medications. They are a major cause of poisoning deaths in the USA exceeding heroin and cocaine. Laboratory testing plays a role in the detection of opioid misuse and the evaluation of patients with opioid intoxication. Laboratories use both immunoassay and chromatographic methods (e.g., liquid chromatography with mass spectrometry detection), often in combination, to yield high detection sensitivity and drug specificity. Testing methods for opioids originated in the workplace-testing arena and focused on detection of illicit heroin use. Analysis for a wide range of opioids is now required in the context of the prescription opioid epidemic. Testing methods have also been primarily based upon urine screening; however, methods for analyzing alternative samples such as saliva, sweat, and hair are available. Application of testing to monitor prescription opioid drug therapy is an increasingly important use of drug testing, and this area of testing introduces new interpretative challenges. In particular, drug metabolism may transform one clinically available opioid into another. The sensitivity of testing methods also varies considerably across the spectrum of opioid drugs. An understanding of opioid metabolism and method sensitivity towards different opioid drugs is therefore essential to effective use of these tests. Improved testing algorithms and more research into the effective use of drug testing in the clinical setting, particularly in pain medicine and substance abuse, are needed.
Collapse
|