1
|
Park SK, Shin JH, Lee DU, Jung JH, Hwang I, Yoo SH, Lee HC, Park I, Kim W, Lee DY, Choi DY. Facile Fabrication of Multifunctional Hydrogel Nanoweb Coating Using Carboxymethyl Chitosan-Based Short Nanofibers for Blood-Contacting Medical Devices. NANO LETTERS 2024; 24:8920-8928. [PMID: 38874568 DOI: 10.1021/acs.nanolett.4c01659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2024]
Abstract
Blood-contacting medical devices (BCDs) require antithrombotic, antibacterial, and low-friction surfaces. Incorporating a nanostructured surface with the functional hydrogel onto BCD surfaces can enhance the performances; however, their fabrication remains challenging. Here, we introduce a straightforward method to fabricate a multifunctional hydrogel-based nanostructure on BCD surfaces using O-carboxymethyl chitosan-based short nanofibers (CMC-SNFs). CMC-SNFs, fabricated via electrospinning and cutting processes, are easily sprayed and entangled onto the BCD surface. The deposited CMC-SNFs form a robust nanoweb layer via fusion at the contact area of the nanofiber interfaces. The superhydrophilic CMC-SNF nanoweb surface creates a water-bound layer that effectively prevents the nonspecific adhesion of bacteria and blood cells, thereby enhancing both antimicrobial and antithrombotic performances. Furthermore, the CMC-SNF nanoweb exhibits excellent lubricity and durability on the bovine aorta. The demonstration results of the CMC-SNF coating on catheters and sheaths provide evidence of its capability to apply multifunctional surfaces simply for diverse BCDs.
Collapse
Affiliation(s)
- Se Kye Park
- Biomedical Manufacturing Technology Center, Korea Institute of Industrial Technology, Yeongcheon 38822, Republic of Korea
- Department of Polymer Science and Engineering, Kyungpook National University, Daegu 41566, Republic of Korea
| | - Jae Hak Shin
- Department of Mechanical Engineering, Sejong University, Seoul 05006, Republic of Korea
| | - Dong Uk Lee
- Biomedical Manufacturing Technology Center, Korea Institute of Industrial Technology, Yeongcheon 38822, Republic of Korea
| | - Jae Hee Jung
- Department of Mechanical Engineering, Sejong University, Seoul 05006, Republic of Korea
| | - Injoo Hwang
- Department of Mechanical Engineering, Silla University, Busan 46958, Republic of Korea
| | - Seung Hwa Yoo
- Department of Quantum System Engineering, Jeonbuk National University, Jeonju 54896, Republic of Korea
| | - Han Chang Lee
- Biomedical Manufacturing Technology Center, Korea Institute of Industrial Technology, Yeongcheon 38822, Republic of Korea
| | - Inyong Park
- Department of Sustainable Environment Research, Korea Institute of Machinery and Materials, Daejeon 34103, Republic of Korea
| | - Woojin Kim
- Biomedical Manufacturing Technology Center, Korea Institute of Industrial Technology, Yeongcheon 38822, Republic of Korea
| | - Dong Yun Lee
- Department of Polymer Science and Engineering, Kyungpook National University, Daegu 41566, Republic of Korea
| | - Dong Yun Choi
- Biomedical Manufacturing Technology Center, Korea Institute of Industrial Technology, Yeongcheon 38822, Republic of Korea
| |
Collapse
|
2
|
Inuzuka N, Shobayashi Y, Tateshima S, Sato Y, Ohba Y, Ekdahl KN, Nilsson B, Teramura Y. Stent coating containing a charged silane coupling agent that regulates protein adsorption to confer antithrombotic and cell-adhesion properties. Sci Rep 2024; 14:15178. [PMID: 38987553 PMCID: PMC11237119 DOI: 10.1038/s41598-024-65832-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Accepted: 06/24/2024] [Indexed: 07/12/2024] Open
Abstract
The evolution of endovascular therapies, particularly in the field of intracranial aneurysm treatment, has been truly remarkable and is characterized by the development of various stents. However, ischemic complications related to thrombosis or downstream emboli pose a challenge for the broader clinical application of such stents. Despite advancements in surface modification technologies, an ideal coating that fulfills all the desired requirements, including anti-thrombogenicity and swift endothelialization, has not been available. To address these issues, we investigated a new coating comprising 3-aminopropyltriethoxysilane (APTES) with both anti-thrombogenic and cell-adhesion properties. We assessed the anti-thrombogenic property of the coating using an in vitro blood loop model by evaluating the platelet count and the level of the thrombin-antithrombin (TAT) complex, and investigating thrombus formation on the surface using scanning electron microscopy (SEM). We then assessed endothelial cell adhesion on the metal surfaces. In vitro blood tests revealed that, compared to a bare stent, the coating significantly inhibited platelet reduction and thrombus formation; more human serum albumin spontaneously adhered to the coated surface to block thrombogenic activation in the blood. Cell adhesion tests also indicated a significant increase in the number of cells adhering to the APTES-coated surfaces compared to the numbers adhering to either the bare stent or the stent coated with an anti-fouling phospholipid polymer. Finally, we performed an in vivo safety test by implanting coated stents into the internal thoracic arteries and ascending pharyngeal arteries of minipigs, and subsequently assessing the health status and vessel patency of the arteries by angiography over the course of 1 week. We found that there were no adverse effects on the pigs and the vascular lumens of their vessels were well maintained in the group with APTES-coated stents. Therefore, our new coating exhibited both high anti-thrombogenicity and cell-adhesion properties, which fulfill the requirements of an implantable stent.
Collapse
Affiliation(s)
- Naoki Inuzuka
- R&D Department, Japan Medical Device Startup Incubation Program, 3-7-2 Nihonbashihon-cho, Chuo-ku, Tokyo, 103-0023, Japan
- R&D Department, N.B. Medical Inc., 3-7-2 Nihonbashihon-cho, Chuo-ku, Tokyo, 103-0023, Japan
| | - Yasuhiro Shobayashi
- R&D Department, N.B. Medical Inc., 3-7-2 Nihonbashihon-cho, Chuo-ku, Tokyo, 103-0023, Japan
| | - Satoshi Tateshima
- Division of Interventional Neuroradiology, Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles (UCLA), Ronald Reagan UCLA Medical Center, 757 Westwood Plaza, Suite 2129, Los Angeles, CA, 90095, USA
| | - Yuya Sato
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan
| | - Yoshio Ohba
- Cellular and Molecular Biotechnology Research Institute (CMB), National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8565, Japan
| | - Kristina N Ekdahl
- Department of Immunology, Genetics and Pathology (IGP), Uppsala University, Dag Hammarskjölds väg 20, 751 85, Uppsala, Sweden
| | - Bo Nilsson
- Department of Immunology, Genetics and Pathology (IGP), Uppsala University, Dag Hammarskjölds väg 20, 751 85, Uppsala, Sweden
| | - Yuji Teramura
- Cellular and Molecular Biotechnology Research Institute (CMB), National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8565, Japan.
- Department of Immunology, Genetics and Pathology (IGP), Uppsala University, Dag Hammarskjölds väg 20, 751 85, Uppsala, Sweden.
- Master's/Doctoral Program in Life Science Innovation (T-LSI), University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8577, Japan.
| |
Collapse
|
3
|
Li J, Barlow LN, Martinez Santos M, Sask KN. Polydopamine modification of polydimethylsiloxane for multifunctional biomaterials: Immobilization and stability of albumin and fetuin-A on modified surfaces. Biointerphases 2022; 18:061004. [PMID: 38085011 DOI: 10.1116/6.0003078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 11/14/2023] [Indexed: 12/18/2023] Open
Abstract
The surface of polydimethylsiloxane (PDMS) can be modified to immobilize proteins; however, most existing approaches are limited to complex reactions and achieving multifunctional modifications is challenging. This work applies a simple technique to modify PDMS using polydopamine (PDA) and investigates immobilization of multiple proteins. The surfaces were characterized in detail and stability was assessed, demonstrating that in a buffer solution, PDA modification was maintained without an effect on surface properties. Bovine serum albumin (BSA) and bovine fetuin-A (Fet-A) were used as model biomolecules for simultaneous or sequential immobilization and to understand their use for surface backfilling and functionalization. Based on 125I radiolabeling, amounts of BSA and Fet-A on PDA were determined to be close to double that were obtained on control PDMS surfaces. Following elution with sodium dodecyl sulfate, around 67% of BSA and 63% of Fet-A were retained on the surface. The amount of immobilized protein was influenced by the process (simultaneous or sequential) and surface affinity of the proteins. With simultaneous modification, a balanced level of both proteins could be achieved, whereas with the sequential process, the initially immobilized protein was more strongly attached. After incubation with plasma and fetal bovine serum, the PDA-modified surfaces maintained over 90% of the proteins immobilized. This demonstrates that the biological environments also play an important role in the binding and stability of conjugated proteins. This combination of PDA and surface immobilization methods provides fundamental knowledge for tailoring multifunctional PDMS-based biomaterials with applications in cell-material interactions, biosensing, and medical devices.
Collapse
Affiliation(s)
- Jie Li
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Leah N Barlow
- Integrated Biomedical Engineering and Health Sciences Program, McMaster University, Hamilton, Ontario L8S 4L8, Canada
- Department of Materials Science and Engineering, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Miguel Martinez Santos
- Integrated Biomedical Engineering and Health Sciences Program, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| | - Kyla N Sask
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario L8S 4L8, Canada
- Integrated Biomedical Engineering and Health Sciences Program, McMaster University, Hamilton, Ontario L8S 4L8, Canada
- Department of Materials Science and Engineering, McMaster University, Hamilton, Ontario L8S 4L8, Canada
| |
Collapse
|
4
|
Große-Berkenbusch K, Avci-Adali M, Arnold M, Cahalan L, Cahalan P, Velic A, Maček B, Schlensak C, Wendel HP, Stoppelkamp S. Profiling of time-dependent human plasma protein adsorption on non-coated and heparin-coated oxygenator membranes. BIOMATERIALS ADVANCES 2022; 139:213014. [PMID: 35882160 DOI: 10.1016/j.bioadv.2022.213014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 06/02/2022] [Accepted: 06/30/2022] [Indexed: 01/07/2023]
Abstract
Patients with severe lung diseases are highly dependent on lung support systems. Despite many improvements, long-term use is not possible, mainly because of the strong body defence reactions (e.g. coagulation, complement system, inflammation and cell activation). The systematic characterization of adsorbed proteins on the gas exchange membrane of the lung system over time can provide insights into the course of various defence reactions and identify possible targets for surface modifications. Using comprehensive mass spectrometry analyses of desorbed proteins, we were able to identify for the first time binding profiles of over 500 proteins over a period of six hours on non-coated and heparin-coated PMP hollow fiber membranes. We observed a higher degree of remodeling of the protein layer on the non-coated membrane than on the coated membrane. In general, there was a higher protein binding on the coated membrane with exception of proteins with a heparin-binding site. Focusing on the most important pathways showed that almost all coagulation factors bound in higher amounts to the non-coated membranes. Furthermore, we could show that the initiator proteins of the complement system bound stronger to the heparinized membranes, but the subsequently activated proteins bound stronger to the non-coated membranes, thus complement activation on heparinized surfaces is mainly due to the alternative complement pathway. Our results provide a comprehensive insight into plasma protein adsorption on oxygenator membranes over time and point to new ways to better understand the processes on the membranes and to develop new specific surface modifications.
Collapse
Affiliation(s)
- Katharina Große-Berkenbusch
- Clinical Research Laboratory, Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, University of Tübingen, Calwerstr. 7/1, 72076 Tübingen, Germany
| | - Meltem Avci-Adali
- Clinical Research Laboratory, Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, University of Tübingen, Calwerstr. 7/1, 72076 Tübingen, Germany
| | - Madeleine Arnold
- Clinical Research Laboratory, Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, University of Tübingen, Calwerstr. 7/1, 72076 Tübingen, Germany
| | - Linda Cahalan
- Ension Inc, 508 Pittsburg Road, Butler, PA 16002, United States of America
| | - Patrick Cahalan
- Ension Inc, 508 Pittsburg Road, Butler, PA 16002, United States of America
| | - Ana Velic
- Proteome Center Tübingen, Interfaculty Institute for Cell Biology, University of Tübingen, Auf der Morgenstelle 15, 72076 Tübingen, Germany
| | - Boris Maček
- Proteome Center Tübingen, Interfaculty Institute for Cell Biology, University of Tübingen, Auf der Morgenstelle 15, 72076 Tübingen, Germany
| | - Christian Schlensak
- Clinical Research Laboratory, Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, University of Tübingen, Calwerstr. 7/1, 72076 Tübingen, Germany
| | - Hans Peter Wendel
- Clinical Research Laboratory, Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, University of Tübingen, Calwerstr. 7/1, 72076 Tübingen, Germany
| | - Sandra Stoppelkamp
- Clinical Research Laboratory, Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, University of Tübingen, Calwerstr. 7/1, 72076 Tübingen, Germany.
| |
Collapse
|
5
|
Feito MJ, Casarrubios L, Oñaderra M, Gómez-Duro M, Arribas P, Polo-Montalvo A, Vallet-Regí M, Arcos D, Portolés MT. Response of RAW 264.7 and J774A.1 macrophages to particles and nanoparticles of a mesoporous bioactive glass: A comparative study. Colloids Surf B Biointerfaces 2021; 208:112110. [PMID: 34555654 DOI: 10.1016/j.colsurfb.2021.112110] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/06/2021] [Accepted: 09/07/2021] [Indexed: 12/21/2022]
Abstract
Mesoporous bioactive glasses (MBGs) are bioceramics designed to induce bone tissue regeneration and very useful materials with the ability to act as drug delivery systems. MBGs can be implanted in contact with bone tissue in different ways, as particulate material, in 3D scaffolds or as nanospheres. In this work, we assessed the effects of particles of mesoporous bioactive glass MBG-75S and mesoporous nanospheres NanoMBG-75S on RAW 264.7 and J774A.1 macrophages, which present different sensitivity and are considered as ideal models for the study of innate immune response. After evaluating several cellular parameters (morphology, size, complexity, proliferation, cell cycle and intracellular content of reactive oxygen species), the action of MBG-75S particles and NanoMBG-75S on the polarization of these macrophages towards the pro-inflammatory (M1) or reparative (M2) phenotype was determined by the expression of specific M1 (CD80) and M2 (CD206, CD163) markers. We previously measured the adsorption of albumin and fibrinogen on MBG-75S particles and the production of pro-inflammatory cytokines as TNF-α and IL-6 by macrophages in response to these particles. This comparative study demonstrates that particles of mesoporous bioactive glass MBG-75S and mesoporous nanospheres NanoMBG-75S allow the appropriated development and function of RAW 264.7 and J774A.1 macrophages and do not induce polarization towards the M1 pro-inflammatory phenotype. Therefore, considering that these mesoporous biomaterials offer the possibility of loading drugs into their pores, the results obtained indicate their high potential for use as drug-delivery systems in bone repair and osteoporosis treatments without triggering an adverse inflammatory response.
Collapse
Affiliation(s)
- M J Feito
- Departamento de Bioquímica y Biología Molecular, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain.
| | - L Casarrubios
- Departamento de Bioquímica y Biología Molecular, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain
| | - M Oñaderra
- Departamento de Bioquímica y Biología Molecular, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain
| | - M Gómez-Duro
- Departamento de Bioquímica y Biología Molecular, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain
| | - P Arribas
- Departamento de Bioquímica y Biología Molecular, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain
| | - A Polo-Montalvo
- Departamento de Bioquímica y Biología Molecular, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain
| | - M Vallet-Regí
- Departamento de Química en Ciencias Farmacéuticas, Facultad de Farmacia, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria Hospital 12 de Octubre i+12, Plaza Ramón y Cajal s/n, 28040 Madrid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, CIBER-BBN, 28040 Madrid, Spain.
| | - D Arcos
- Departamento de Química en Ciencias Farmacéuticas, Facultad de Farmacia, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria Hospital 12 de Octubre i+12, Plaza Ramón y Cajal s/n, 28040 Madrid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, CIBER-BBN, 28040 Madrid, Spain
| | - M T Portolés
- Departamento de Bioquímica y Biología Molecular, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), 28040 Madrid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, CIBER-BBN, 28040 Madrid, Spain.
| |
Collapse
|
6
|
D’Agata R, Bellassai N, Jungbluth V, Spoto G. Recent Advances in Antifouling Materials for Surface Plasmon Resonance Biosensing in Clinical Diagnostics and Food Safety. Polymers (Basel) 2021; 13:1929. [PMID: 34200632 PMCID: PMC8229487 DOI: 10.3390/polym13121929] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 06/07/2021] [Accepted: 06/07/2021] [Indexed: 01/11/2023] Open
Abstract
Strategies to develop antifouling surface coatings are crucial for surface plasmon resonance (SPR) sensing in many analytical application fields, such as detecting human disease biomarkers for clinical diagnostics and monitoring foodborne pathogens and toxins involved in food quality control. In this review, firstly, we provide a brief discussion with considerations about the importance of adopting appropriate antifouling materials for achieving excellent performances in biosensing for food safety and clinical diagnosis. Secondly, a non-exhaustive landscape of polymeric layers is given in the context of surface modification and the mechanism of fouling resistance. Finally, we present an overview of some selected developments in SPR sensing, emphasizing applications of antifouling materials and progress to overcome the challenges related to the detection of targets in complex matrices relevant for diagnosis and food biosensing.
Collapse
Affiliation(s)
- Roberta D’Agata
- Dipartimento di Scienze Chimiche, Università degli Studi di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy; (N.B.); (V.J.)
| | - Noemi Bellassai
- Dipartimento di Scienze Chimiche, Università degli Studi di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy; (N.B.); (V.J.)
| | - Vanessa Jungbluth
- Dipartimento di Scienze Chimiche, Università degli Studi di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy; (N.B.); (V.J.)
| | - Giuseppe Spoto
- Dipartimento di Scienze Chimiche, Università degli Studi di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy; (N.B.); (V.J.)
- Consorzio Interuniversitario “Istituto Nazionale Biostrutture e Biosistemi”, c/o Dipartimento di Scienze Chimiche, Università di Catania, Viale Andrea Doria 6, I-95125 Catania, Italy
| |
Collapse
|
7
|
D'Agata R, Bellassai N, Giuffrida MC, Aura AM, Petri C, Kögler P, Vecchio G, Jonas U, Spoto G. A new ultralow fouling surface for the analysis of human plasma samples with surface plasmon resonance. Talanta 2020; 221:121483. [PMID: 33076094 DOI: 10.1016/j.talanta.2020.121483] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 07/23/2020] [Accepted: 07/29/2020] [Indexed: 01/08/2023]
Abstract
Surface plasmon resonance (SPR) has been widely used to detect a variety of biomolecular systems, but only a small fraction of applications report on the analysis of patients' samples. A critical barrier to the full implementation of SPR technology in molecular diagnostics currently exists for its potential application to analyze blood plasma or serum samples. Such capability is mostly hindered by the non-specific adsorption of interfering species present in the biological sample at the functional interface of the biosensor, often referred to as fouling. Suitable polymeric layers having a thickness ranging from 15 and about 70 nm are usually deposited on the active surface of biosensors to introduce antifouling properties. A similar approach is not fully adequate for SPR detection where the exponential decay of the evanescent plasmonic field limits the thickness of the layer beyond the SPR metallic sensor surface for which a sensitive detection can be obtained. Here, a triethylene glycol (PEG(3))-pentrimer carboxybetaine system is proposed to fabricate a new surface coating bearing excellent antifouling properties with a thickness of less than 2 nm, thus compatible with sensitive SPR detection. The high variability of experimental conditions described in the literature for the quantitative assessment of the antifouling performances of surface layers moved us to compare the superior antifouling capacity of the new pentrimeric system with that of 4-aminophenylphosphorylcholine, PEG-carboxybetaine and sulfobetaine-modified surface layers, respectively, using undiluted and diluted pooled human plasma samples. The use of the new coating for the immunologic SPRI biosensing of human arginase 1 in plasma is also presented.
Collapse
Affiliation(s)
- Roberta D'Agata
- Dipartimento di Scienze Chimiche, Università Degli Studi di Catania, Viale Andrea Doria 6, Catania, Italy
| | - Noemi Bellassai
- Dipartimento di Scienze Chimiche, Università Degli Studi di Catania, Viale Andrea Doria 6, Catania, Italy
| | - Maria Chiara Giuffrida
- Consorzio Interuniversitario "Istituto Nazionale Biostrutture e Biosistemi", c/o Dipartimento di Scienze Chimiche, Università di Catania, Viale Andrea Doria 6, Catania, Italy
| | - Angela Margherita Aura
- Dipartimento di Scienze Chimiche, Università Degli Studi di Catania, Viale Andrea Doria 6, Catania, Italy
| | - Christian Petri
- Department Chemistry - Biology, University of Siegen, Adolf-Reichwein-Strasse 2, D-57076, Siegen, Germany
| | - Peter Kögler
- Department Chemistry - Biology, University of Siegen, Adolf-Reichwein-Strasse 2, D-57076, Siegen, Germany
| | - Graziella Vecchio
- Dipartimento di Scienze Chimiche, Università Degli Studi di Catania, Viale Andrea Doria 6, Catania, Italy
| | - Ulrich Jonas
- Department Chemistry - Biology, University of Siegen, Adolf-Reichwein-Strasse 2, D-57076, Siegen, Germany
| | - Giuseppe Spoto
- Dipartimento di Scienze Chimiche, Università Degli Studi di Catania, Viale Andrea Doria 6, Catania, Italy; Consorzio Interuniversitario "Istituto Nazionale Biostrutture e Biosistemi", c/o Dipartimento di Scienze Chimiche, Università di Catania, Viale Andrea Doria 6, Catania, Italy.
| |
Collapse
|
8
|
Kim J. Systematic approach to characterize the dynamics of protein adsorption on the surface of biomaterials using proteomics. Colloids Surf B Biointerfaces 2020; 188:110756. [DOI: 10.1016/j.colsurfb.2019.110756] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 12/03/2019] [Accepted: 12/23/2019] [Indexed: 01/08/2023]
|
9
|
Brash JL, Horbett TA, Latour RA, Tengvall P. The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity. Acta Biomater 2019; 94:11-24. [PMID: 31226477 PMCID: PMC6642842 DOI: 10.1016/j.actbio.2019.06.022] [Citation(s) in RCA: 112] [Impact Index Per Article: 22.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 06/13/2019] [Indexed: 12/13/2022]
Abstract
The adsorption of proteins is the initiating event in the processes occurring when blood contacts a "foreign" surface in a medical device, leading inevitably to thrombus formation. Knowledge of protein adsorption in this context has accumulated over many years but remains fragmentary and incomplete. Moreover, the significance and relevance of the information for blood compatibility are not entirely agreed upon in the biomaterials research community. In this review, protein adsorption from blood is discussed under the headings "agreed upon" and "not agreed upon or not known" with respect to: protein layer composition, effects on coagulation and complement activation, effects on platelet adhesion and activation, protein conformational change and denaturation, prevention of nonspecific protein adsorption, and controlling/tailoring the protein layer composition. STATEMENT OF SIGNIFICANCE: This paper is part 2 of a series of 4 reviews discussing the problem of biomaterial associated thrombogenicity. The objective was to highlight features of broad agreement and provide commentary on those aspects of the problem that were subject to dispute. We hope that future investigators will update these reviews as new scholarship resolves the uncertainties of today.
Collapse
|
10
|
Mansour A, Abu-Nada L, Al-Waeli H, Mezour MA, Abdallah MN, Kinsella JM, Kort-Mascort J, Henderson JE, Ramirez-Garcialuna JL, Tran SD, Elkashty OA, Mousa A, El-Hadad AA, Taqi D, Al-Hamad F, Alageel O, Kaartinen MT, Tamimi F. Bone extracts immunomodulate and enhance the regenerative performance of dicalcium phosphates bioceramics. Acta Biomater 2019; 89:343-358. [PMID: 30853609 DOI: 10.1016/j.actbio.2019.03.012] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 02/28/2019] [Accepted: 03/06/2019] [Indexed: 12/27/2022]
Abstract
Immunomodulation strategies are believed to improve the integration and clinical performance of synthetic bone substitutes. One potential approach is the modification of biomaterial surface chemistry to mimic bone extracellular matrix (ECM). In this sense, we hypothesized that coating synthetic dicalcium phosphate (DCP) bioceramics with bone ECM proteins would modulate the host immune reactions and improve their regenerative performance. To test this, we evaluated the in vitro proteomic surface interactions and the in vivo performance of ECM-coated bioceramic scaffolds. Our results demonstrated that coating DCP scaffolds with bone extracts, specifically those containing calcium-binding proteins, dramatically modulated their interaction with plasma proteins in vitro, especially those relating to the innate immune response. In vivo, we observed an attenuated inflammatory response against the bioceramic scaffolds and enhanced peri-scaffold new bone formation supported by the increased osteoblastogenesis and reduced osteoclastogenesis. Furthermore, the bone extract rich in calcium-binding proteins can be 3D-printed to produce customized hydrogels with improved regeneration capabilities. In summary, bone extracts containing calcium-binding proteins can enhance the integration of synthetic biomaterials and improve their ability to regenerate bone probably by modulating the host immune reaction. This finding helps understand how bone allografts regenerate bone and opens the door for new advances in tissue engineering and bone regeneration. STATEMENT OF SIGNIFICANCE: Foreign-body reaction is an important determinant of in vivo biomaterial integration, as an undesired host immune response can compromise the performance of an implanted biomaterial. For this reason, applying immunomodulation strategies to enhance biomaterial engraftment is of great interest in the field of regenerative medicine. In this article, we illustrated that coating dicalcium phosphate bioceramic scaffolds with bone-ECM extracts, especially those rich in calcium-binding proteins, is a promising approach to improve their surface proteomic interactions and modulate the immune responses towards such biomaterials in a way that improves their bone regeneration performance. Collectively, the results of this study may provide a conceivable explanation for the mechanisms involved in presenting the excellent regenerative efficacy of natural bone grafts.
Collapse
Affiliation(s)
- Alaa Mansour
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| | - Lina Abu-Nada
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| | - Haider Al-Waeli
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| | | | | | - Joseph M Kinsella
- Department of Bioengineering, Faculty of Engineering, McGill University, Montreal, QC, Canada.
| | - Jacqueline Kort-Mascort
- Department of Bioengineering, Faculty of Engineering, McGill University, Montreal, QC, Canada.
| | - Janet E Henderson
- Faculty of Medicine, McGill University, Montreal, QC, Canada; The Bone Engineering Labs, Research Institute McGill University Health Center, Montreal, QC, Canada.
| | - Jose Luis Ramirez-Garcialuna
- Faculty of Medicine, McGill University, Montreal, QC, Canada; The Bone Engineering Labs, Research Institute McGill University Health Center, Montreal, QC, Canada.
| | - Simon D Tran
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| | - Osama A Elkashty
- Faculty of Medicine, McGill University, Montreal, QC, Canada; Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
| | - Aisha Mousa
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| | - Amir A El-Hadad
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| | - Doaa Taqi
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| | - Faez Al-Hamad
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| | - Omar Alageel
- Faculty of Dentistry, McGill University, Montreal, QC, Canada; College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
| | | | - Faleh Tamimi
- Faculty of Dentistry, McGill University, Montreal, QC, Canada.
| |
Collapse
|
11
|
Loza-Correa M, Kalab M, Yi QL, Eltringham-Smith LJ, Sheffield WP, Ramirez-Arcos S. Comparison of bacterial attachment to platelet bags with and without preconditioning with plasma. Vox Sang 2017; 112:401-407. [DOI: 10.1111/vox.12513] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Revised: 02/16/2017] [Accepted: 02/19/2017] [Indexed: 01/16/2023]
Affiliation(s)
- M. Loza-Correa
- Canadian Blood Services; Centre for Innovation; Ottawa ON Canada
| | - M. Kalab
- Agriculture and Agri-Food Canada; Ottawa ON Canada
| | - Q.-L. Yi
- Canadian Blood Services; Centre for Innovation; Ottawa ON Canada
| | | | - W. P. Sheffield
- Department of Pathology and Molecular Medicine; McMaster University; Hamilton ON Canada
- Canadian Blood Services; Centre for Innovation; Hamilton ON Canada
| | - S. Ramirez-Arcos
- Canadian Blood Services; Centre for Innovation; Ottawa ON Canada
| |
Collapse
|
12
|
Abstract
The design and application of sensors for monitoring biomolecules in clinical samples is a common goal of the sensing research community. Surface plasmon resonance (SPR) and other plasmonic techniques such as localized surface plasmon resonance (LSPR) and imaging SPR are reaching a maturity level sufficient for their application in monitoring biomolecules in clinical samples. In recent years, the first examples for monitoring antibodies, proteins, enzymes, drugs, small molecules, peptides, and nucleic acids in biofluids collected from patients afflicted with a series of medical conditions (Alzheimer's, hepatitis, diabetes, leukemia, and cancers such as prostate and breast cancers, among others) demonstrate the progress of SPR sensing in clinical chemistry. This Perspective reviews the current status of the field, showcasing a series of early successes in the application of SPR for clinical analysis and detailing a series of considerations regarding sensing schemes, exposing issues with analysis in biofluids, and comparing SPR with ELISA, while providing an outlook of the challenges currently associated with plasmonic materials, instrumentation, microfluidics, bioreceptor selection, selection of a clinical market, and validation of a clinical assay for applying SPR sensors to clinical samples. Research opportunities are proposed to further advance the field and transition SPR biosensors from research proof-of-concept stage to actual clinical applications.
Collapse
Affiliation(s)
- Jean-Francois Masson
- Département
de chimie, Université de Montréal, C.P. 6128 Succ. Centre-Ville, Montreal, Quebec H3C 3J7, Canada
- Centre
for self-assembled chemical structures (CSACS), McGill University, 801
Sherbrooke Street West, Montreal, Quebec H3A 2K6, Canada
| |
Collapse
|
13
|
Blaszykowski C, Sheikh S, Thompson M. A survey of state-of-the-art surface chemistries to minimize fouling from human and animal biofluids. Biomater Sci 2015. [DOI: 10.1039/c5bm00085h] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Fouling of artificial surfaces by biofluids is a plague Biotechnology deeply suffers from. Herein, we inventory the state-of-the-art surface chemistries developed to minimize this effect from both human and animal biosamples.
Collapse
Affiliation(s)
| | - Sonia Sheikh
- University of Toronto
- Department of Chemistry – St. George campus
- Toronto
- Canada M5S 3H6
| | - Michael Thompson
- Econous Systems Inc
- Toronto
- Canada M5S 3H6
- University of Toronto
- Department of Chemistry – St. George campus
| |
Collapse
|
14
|
Xu LC, Bauer JW, Siedlecki CA. Proteins, platelets, and blood coagulation at biomaterial interfaces. Colloids Surf B Biointerfaces 2014; 124:49-68. [PMID: 25448722 PMCID: PMC5001692 DOI: 10.1016/j.colsurfb.2014.09.040] [Citation(s) in RCA: 248] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Revised: 09/15/2014] [Accepted: 09/18/2014] [Indexed: 12/24/2022]
Abstract
Blood coagulation and platelet adhesion remain major impediments to the use of biomaterials in implantable medical devices. There is still significant controversy and question in the field regarding the role that surfaces play in this process. This manuscript addresses this topic area and reports on state of the art in the field. Particular emphasis is placed on the subject of surface engineering and surface measurements that allow for control and observation of surface-mediated biological responses in blood and test solutions. Appropriate use of surface texturing and chemical patterning methodologies allow for reduction of both blood coagulation and platelet adhesion, and new methods of surface interrogation at high resolution allow for measurement of the relevant biological factors.
Collapse
Affiliation(s)
- Li-Chong Xu
- Department of Surgery, Biomedical Engineering Institute, The Pennsylvania State University, College of Medicine, Hershey, PA 17033, United States
| | - James W Bauer
- Department of Bioengineering, Biomedical Engineering Institute, The Pennsylvania State University, College of Medicine, Hershey, PA 17033, United States
| | - Christopher A Siedlecki
- Department of Surgery, Biomedical Engineering Institute, The Pennsylvania State University, College of Medicine, Hershey, PA 17033, United States; Department of Bioengineering, Biomedical Engineering Institute, The Pennsylvania State University, College of Medicine, Hershey, PA 17033, United States.
| |
Collapse
|
15
|
Leung JM, Berry LR, Chan AKC, Brash JL. Surface modification of polydimethylsiloxane with a covalent antithrombin-heparin complex to prevent thrombosis. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2014; 25:786-801. [PMID: 24735089 DOI: 10.1080/09205063.2014.907669] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
To prevent coagulation in contact with blood, polydimethylsiloxane (PDMS) was modified with an antithrombin-heparin (ATH) covalent complex using polyethylene glycol (PEG) as a linker/spacer. Using NHS chemistry, ATH was attached covalently to the distal chain end of the immobilized PEG linker. Surfaces were characterized by contact angle and X-ray photoelectron spectroscopy; attachment was confirmed by decrease in contact angles and an increase in nitrogen content as determined by X-ray photoelectron spectroscopy. Protein interactions in plasma were investigated using radiolabeled proteins added to plasma as tracers, and by immunoblotting of eluted proteins. Modification of PDMS with PEG alone was effective in reducing non-specific protein adsorption; attachment of ATH at the distal end of the PEG chains did not significantly affect protein resistance. It was shown that surfaces modified with ATH bound antithrombin selectively from plasma through the pentasaccharide sequence on the heparin moiety of ATH, indicating the ability of the ATH-modified surfaces to inhibit coagulation. Using thromboelastography, the effect of ATH modification on plasma coagulation was evaluated directly. It was found that initiation of coagulation was delayed and the time to clot was prolonged on PDMS modified with ATH/PEG compared to controls. For comparison, surfaces modified in a similar way with heparin were prepared and investigated using the same methods. The data suggest that the ATH-modified surfaces have superior anticoagulant properties compared to those modified with heparin.
Collapse
Affiliation(s)
- Jennifer M Leung
- a School of Biomedical Engineering , Hamilton , Ontario , Canada
| | | | | | | |
Collapse
|
16
|
Rochow N, Manan A, Wu WI, Fusch G, Monkman S, Leung J, Chan E, Nagpal D, Predescu D, Brash J, Selvaganapathy PR, Fusch C. An Integrated Array of Microfluidic Oxygenators as a Neonatal Lung Assist Device: In Vitro Characterization and In Vivo Demonstration. Artif Organs 2014; 38:856-66. [DOI: 10.1111/aor.12269] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Niels Rochow
- Division of Neonatology; Department of Pediatrics; McMaster University; Hamilton Ontario Canada
| | - Asmaa Manan
- School of Biomedical Engineering; McMaster University; Hamilton Ontario Canada
| | - Wen-I Wu
- Department of Mechanical Engineering; McMaster University; Hamilton Ontario Canada
| | - Gerhard Fusch
- Division of Neonatology; Department of Pediatrics; McMaster University; Hamilton Ontario Canada
| | - Shelley Monkman
- Division of Neonatology; Department of Pediatrics; McMaster University; Hamilton Ontario Canada
| | - Jennifer Leung
- Department of Chemical Engineering; McMaster University; Hamilton Ontario Canada
| | - Emily Chan
- Division of Neonatology; Department of Pediatrics; McMaster University; Hamilton Ontario Canada
| | - Dipen Nagpal
- Department of Mechanical Engineering; McMaster University; Hamilton Ontario Canada
| | - Dragos Predescu
- Division of Cardiology; Department of Pediatrics; McMaster University; Hamilton Ontario Canada
| | - John Brash
- School of Biomedical Engineering; McMaster University; Hamilton Ontario Canada
- Department of Chemical Engineering; McMaster University; Hamilton Ontario Canada
| | - Ponnambalam Ravi Selvaganapathy
- School of Biomedical Engineering; McMaster University; Hamilton Ontario Canada
- Department of Mechanical Engineering; McMaster University; Hamilton Ontario Canada
| | - Christoph Fusch
- Division of Neonatology; Department of Pediatrics; McMaster University; Hamilton Ontario Canada
- School of Biomedical Engineering; McMaster University; Hamilton Ontario Canada
| |
Collapse
|
17
|
Pereira ADLS, Rodriguez-Emmenegger C, Surman F, Riedel T, Alles AB, Brynda E. Use of pooled blood plasmas in the assessment of fouling resistance. RSC Adv 2014. [DOI: 10.1039/c3ra43093f] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
|
18
|
Lin K, Xia L, Gan J, Zhang Z, Chen H, Jiang X, Chang J. Tailoring the nanostructured surfaces of hydroxyapatite bioceramics to promote protein adsorption, osteoblast growth, and osteogenic differentiation. ACS APPLIED MATERIALS & INTERFACES 2013; 5:8008-17. [PMID: 23862579 DOI: 10.1021/am402089w] [Citation(s) in RCA: 134] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
To promote and understand the biological responses of the implant via nanostructured surface design is essential for the development of bioactive bone implants. However, the control of the surface topography of the bioceramics in nanoscale is a big challenge because of their brittle property. Herein, the hydroxyapatite (HAp) bioceramics with distinct nanostructured topographies were fabricated via hydrothermal treatment using α-tricalcium phosphate ceramic as hard-template under different reaction conditions. HAp bioceramics with nanosheet, nanorod and micro-nanohybrid structured surface in macroscopical size were obtained by controlling the composition of the reaction media. Comparing with the traditional sample with flat and dense surface, the fabricated HAp bioceramics with hierarchical 3D micro-nanotextured surfaces possessed higher specific surface area, which selectively enhanced adsorption of specific proteins including Fn and Vn in plasma, and stimulated osteoblast adhesion, growth, and osoteogenic differentiation. In particular, the biomimetic features of the hierarchical micro-nanohybrid surface resulted in the best ability for simultaneous enhancement of protein adsorption, osteoblast proliferation, and differentiation. The results suggest that the hierarchical micro-nanohybrid topography might be one of the critical factors to be considered in the design of functional bone grafts.
Collapse
Affiliation(s)
- Kaili Lin
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, China
| | | | | | | | | | | | | |
Collapse
|
19
|
Love RJ, Jones KS. The recognition of biomaterials: pattern recognition of medical polymers and their adsorbed biomolecules. J Biomed Mater Res A 2013; 101:2740-52. [PMID: 23613455 DOI: 10.1002/jbm.a.34577] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Revised: 01/04/2013] [Indexed: 12/31/2022]
Abstract
All biomedical materials are recognized as foreign entities by the host immune system despite the substantial range of different materials that have been developed by material scientists and engineers. Hydrophobic biomaterials, hydrogels, biomaterials with low protein binding surfaces, and those that readily adsorb a protein layer all seem to incite similar host responses in vivo that may differ in magnitude, but ultimately result in encapsulation by fibrotic tissue. The recognition of medical materials by the host is explained by the very intricate pattern recognition system made up of integrins, toll-like receptors, scavenger receptors, and other surface proteins that enable leukocytes to perceive almost any foreign body. In this review, we describe the various pattern recognition receptors and processes that occur on biomedical material surfaces that permit detection of a range of materials within the host.
Collapse
Affiliation(s)
- Ryan J Love
- School of Biomedical Engineering, McMaster University, Hamilton, Ontarion, Canada
| | | |
Collapse
|
20
|
Riedel T, Riedelová-Reicheltová Z, Májek P, Rodriguez-Emmenegger C, Houska M, Dyr JE, Brynda E. Complete identification of proteins responsible for human blood plasma fouling on poly(ethylene glycol)-based surfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2013; 29:3388-3397. [PMID: 23391268 DOI: 10.1021/la304886r] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The resistance of poly(ethylene glycol) (PEG) against protein adsorption is crucial and has been widely utilized in various biomedical applications. In this work, the complete protein composition of biofilms deposited on PEG-based surfaces from human blood plasma (BP) was identified for the first time using nanoLC-MS/MS, a powerful tool in protein analysis. The mass of deposited BP and the number of different proteins contained in the deposits on individual surfaces decreased in the order of self-assembling monolayers of oligo(ethylene glycol) alkanethiolates (SAM) > poly(ethylene glycol) end-grafted onto a SAM > poly(oligo(ethylene glycol) methacrylate) brushes prepared by surface initiated polymerization (poly(OEGMA)). The BP deposit on the poly(OEGMA) surface was composed only of apolipoprotein A-I, apolipoprotein B-100, complement C3, complement C4-A, complement C4-B, histidine-rich glycoprotein, Ig mu chain C region, fibrinogen (Fbg), and serum albumin (HSA). The total resistance of the surface to the Fbg and HSA adsorption from single protein solutions suggested that their deposition from BP was mediated by some of the other proteins. Current theories of protein resistance are not sufficient to explain the observed plasma fouling. The research focused on the identified proteins, and the experimental approach used in this work can provide the basis for the understanding and rational design of plasma-resistant surfaces.
Collapse
Affiliation(s)
- Tomáš Riedel
- Department of Biomaterials and Bioanalogous Systems, Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, vvi, Prague, Czech Republic
| | | | | | | | | | | | | |
Collapse
|
21
|
Protein Adsorption Patterns and Analysis on IV Nanoemulsions-The Key Factor Determining the Organ Distribution. Pharmaceutics 2012; 5:36-68. [PMID: 24300396 PMCID: PMC3834939 DOI: 10.3390/pharmaceutics5010036] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Revised: 11/30/2012] [Accepted: 12/04/2012] [Indexed: 11/23/2022] Open
Abstract
Intravenous nanoemulsions have been on the market for parenteral nutrition since the 1950s; meanwhile, they have also been used successfully for IV drug delivery. To be well tolerable, the emulsions should avoid uptake by the MPS cells of the body; for drug delivery, they should be target-specific. The organ distribution is determined by the proteins adsorbing them after injection from the blood (protein adsorption pattern), typically analyzed by two-dimensional polyacrylamide gel electrophoresis, 2-D PAGE. The article reviews the 2-D PAGE method, the analytical problems to be faced and the knowledge available on how the composition of emulsions affects the protein adsorption patterns, e.g., the composition of the oil phase, stabilizer layer and drug incorporation into the interface or oil core. Data were re-evaluated and compared, and the implications for the in vivo distribution are discussed. Major results are that the interfacial composition of the stabilizer layer is the main determining factor and that this composition can be modulated by simple processes. Drug incorporation affects the pattern depending on the localization of the drug (oil core versus interface). The data situation regarding in vivo effects is very limited; mainly, it has to be referred to in the in vivo data of polymeric nanoparticles. As a conclusion, determination of the protein adsorption patterns can accelerate IV nanoemulsion formulation development regarding optimized organ distribution and related pharmacokinetics.
Collapse
|
22
|
|
23
|
Battiston KG, Labow RS, Santerre JP. Protein binding mediation of biomaterial-dependent monocyte activation on a degradable polar hydrophobic ionic polyurethane. Biomaterials 2012; 33:8316-28. [DOI: 10.1016/j.biomaterials.2012.08.014] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2012] [Accepted: 08/05/2012] [Indexed: 12/25/2022]
|
24
|
Klenkler BJ, Chen H, Chen Y, Brook MA, Sheardown H. A high-density PEG interfacial layer alters the response to an EGF tethered polydimethylsiloxane surface. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 19:1411-24. [PMID: 18973720 DOI: 10.1163/156856208786140346] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- B. J. Klenkler
- a Department of Chemical Engineering, McMaster University, 1280 Main St. West, Hamilton, ON, Canada L8S 4L7
| | - H. Chen
- b Department of Chemical Engineering, McMaster University, 1280 Main St. West, Hamilton, ON, Canada L8S 4L7; School of Biomedical Engeineering, McMaster University, 1280 Main St. West, Hamilton, ON, Canada L8S 4L7
| | - Y. Chen
- c School of Biomedical Engeineering, McMaster University, 1280 Main St. West, Hamilton, ON, Canada L8S 4L7
| | - M. A. Brook
- d School of Biomedical Engeineering, McMaster University, 1280 Main St. West, Hamilton, ON, Canada L8S 4L7
| | - H. Sheardown
- e Department of Chemical Engineering, McMaster University, 1280 Main St. West, Hamilton, ON, Canada L8S 4L7
| |
Collapse
|
25
|
Chen H, Brook MA, Chen Y, Sheardown H. Surface properties of PEO–silicone composites: reducing protein adsorption. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 16:531-48. [PMID: 15887658 DOI: 10.1163/1568562053700183] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Silicone-based polymers with reduced protein adsorption were successfully prepared by incorporating mono- or bifunctional poly(ethylene oxide) (PEO) derivatives, respectively, into PDMS during rubber formation using classic room temperature vulcanization chemistry. Characterization of the films by water contact-angle measurements and XPS showed that the PEO was present on the film surface, with greater amounts of PEO at the interface modified with monofunctional PEO. Scanning electron microscopy showed the PEO domains segregated into regular zigzag patterns on the PEO-modified surfaces. Significant reductions in the adsorption of fibrinogen, albumin and lysozyme were observed on both PEO-modified surfaces, although the monofunctional PEO surfaces performed much better in this regard. The reductions in protein adsorption were comparable for all three proteins on both surfaces, suggesting that molecular mass of the protein is not a significant factor in determining the magnitude of protein deposition. Western blot studies showed that the adsorption of proteins from plasma to the monofunctional PEO-modified surfaces was also significantly reduced and surprisingly selective, with very few bands noted relative to the control surfaces and those modified with bifunctional PEO.
Collapse
Affiliation(s)
- Hong Chen
- Department of Chemical Engineering, McMaster University, 1280 Main St. W., Hamilton ON, Canada L8S 4L7
| | | | | | | |
Collapse
|
26
|
Sivaraman B, Latour RA. Time-dependent conformational changes in adsorbed albumin and its effect on platelet adhesion. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2012; 28:2745-52. [PMID: 22191731 PMCID: PMC3286649 DOI: 10.1021/la204777x] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Recent studies have shown that platelets can adhere to adsorbed albumin (Alb) through a receptor-mediated mechanism, but only if the Alb undergoes more than a critical degree of adsorption-induced unfolding. The objectives of this research were to investigate whether Alb that was initially adsorbed in a manner that induced unfolding that was less than this critical level would undergo further unfolding with time and, if so, whether this would induce the onset of platelet adhesion once this critical level was exceeded. To address these questions, CD spectropolarimetry was used to monitor the structure of Alb on OH- and CH(3)-functionalized alkanethiol self-assembled monolayer surfaces, with the Alb initially adsorbed under conditions resulting in degrees of unfolding that were below this critical level, and then the adsorbed Alb layers were aged over 6 months in sterile physiological saline at 37 °C. Platelet adhesion to Alb was quantified at selected time points via a lactate dehydrogenase (LDH) assay. The results indicate that an adsorbed Alb layer does undergo further structural changes with increasing residence time and supports platelet adhesion once it unfolds beyond the previously determined critical level. These results may be relevant to the clinically observed problem of the onset of late-thrombosis, which occurs on cardiovascular implants such as drug-eluting stents.
Collapse
|
27
|
Sask KN, Berry LR, Chan AKC, Brash JL. Modification of polyurethane surface with an antithrombin-heparin complex for blood contact: influence of molecular weight of polyethylene oxide used as a linker/spacer. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2012; 28:2099-2106. [PMID: 22149666 DOI: 10.1021/la203821g] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Polyurethane (PU) was modified using isocyanate chemistry to graft polyethylene oxide (PEO) of various molecular weights (range 300-4600). An antithrombin-heparin (ATH) covalent complex was subsequently attached to the free PEO chain ends, which had been functionalized with N-hydroxysuccinimide (NHS) groups. Surfaces were characterized by water contact angle and X-ray photoelectron spectroscopy (XPS) to confirm the modifications. Adsorption of fibrinogen from buffer was found to decrease by ~80% for the PEO-modified surfaces compared to the unmodified PU. The surfaces with ATH attached to the distal chain end of the grafted PEO were equally protein resistant, and when the data were normalized to the ATH surface density, PEO in the lower MW range showed greater protein resistance. Western blots of proteins eluted from the surfaces after plasma contact confirmed these trends. The uptake of ATH on the PEO-modified surfaces was greatest for the PEO of lower MW (300 and 600), and antithrombin binding from plasma (an indicator of heparin anticoagulant activity) was highest for these same surfaces. The PEO-ATH- and PEO-modified surfaces also showed low platelet adhesion from flowing whole blood. It is concluded that for the PEO-ATH surfaces, PEO in the low MW range, specifically MW 600, may be optimal for achieving an appropriate balance between resistance to nonspecific protein adsorption and the ability to take up ATH and bind antithrombin in subsequent blood contact.
Collapse
Affiliation(s)
- Kyla N Sask
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON, Canada L8S 4K1
| | | | | | | |
Collapse
|
28
|
Battiston KG, McBane JE, Labow RS, Paul Santerre J. Differences in protein binding and cytokine release from monocytes on commercially sourced tissue culture polystyrene. Acta Biomater 2012; 8:89-98. [PMID: 21963405 DOI: 10.1016/j.actbio.2011.09.015] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Revised: 09/14/2011] [Accepted: 09/14/2011] [Indexed: 12/23/2022]
Abstract
Tissue culture polystyrene (TCPS) is a ubiquitous substrate used by many researchers in the biomedical and biological sciences. Different parameters involved in the production of TCPS, including the treatment time and the use of reactive gases and chemical agents, can have a significant influence on the ultimate surface properties achieved. The assumption that they will all yield a consistent and controlled product has not proven to be true. To provide a better insight into the bioactivity differences in TCPS supplied by different manufacturers, TCPS from three different companies (Sarstedt, Wisent Corp., and Becton Dickinson (BD)) were analyzed for their surface properties, protein adsorption characteristics, and interactions with human monocytes. Marked differences were observed in terms of surface wettability and surface chemistry. Furthermore, Wisent TCPS adsorbed more than twice the amount of serum proteins compared with BD and Sarstedt TCPS. Sarstedt showed significantly more cell retention (more DNA) compared with both BD and Wisent TCPS brands over a 7 day culture period. Cytokine release from monocytes adherent on the three different TCPS also differed significantly, suggesting that the differences in the surface properties were sufficient to differentially mediate monocyte activation. These results have important implications for TCPS research use, in terms of appreciating the interpretation of the data when TCPS is used as a control substrate as well as when it is used where a pre-conditioned state would influence the outcome of the study.
Collapse
|
29
|
Tsai IY, Tomczyk N, Eckmann JI, Composto RJ, Eckmann DM. Human plasma protein adsorption onto dextranized surfaces: a two-dimensional electrophoresis and mass spectrometry study. Colloids Surf B Biointerfaces 2011; 84:241-52. [PMID: 21277175 PMCID: PMC3079350 DOI: 10.1016/j.colsurfb.2011.01.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2010] [Revised: 12/29/2010] [Accepted: 01/06/2011] [Indexed: 11/19/2022]
Abstract
Protein adsorption is fundamental to thrombosis and to the design of biocompatible materials. We report a two-dimensional electrophoresis and mass spectrometry study to characterize multiple human plasma proteins adsorbed onto four different types of model surfaces: silicon oxide, dextranized silicon, polyurethane and dextranized polyurethane. Dextran was grafted onto the surfaces of silicon and polyurethane to mimic the blood-contacting endothelial cell glycocalyx surface. Surface topography and hydrophobicity/hydrophilicity were determined and analyzed using atomic force microscopy and water contact angle measurements, respectively. Using two-dimensional electrophoresis, we show that, relative to the unmodified surfaces, dextranization significantly inhibits the adsorption of several human plasma proteins including IGHG1 protein, fibrinogen, haptoglobin, Apo A-IV, Apo A-I, immunoglobulin, serum retinal-binding protein and truncated serum albumin. We further demonstrate the selectivity of plasma protein adsorbed onto the different functionalized surfaces and the potential to control and manipulate proteins adsorption on the surfaces of medical devices, implants and microfluidic devices. This result shows that adsorption experiments using a single protein or a binary mixture of proteins are consistent with competitive protein adsorption studies. In summary, these studies indicate that coating blood-contacting biomedical applications with dextran is an effective route to reduce thrombo-inflammatory responses and to surface-direct biological activities.
Collapse
Affiliation(s)
- Irene Y. Tsai
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Nancy Tomczyk
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Joshua I. Eckmann
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Russell J. Composto
- Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - David M. Eckmann
- Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
30
|
Guha Thakurta S, Subramanian A. Evaluation of in situ albumin binding surfaces: a study of protein adsorption and platelet adhesion. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2011; 22:137-149. [PMID: 21120589 DOI: 10.1007/s10856-010-4169-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2010] [Accepted: 10/07/2010] [Indexed: 05/30/2023]
Abstract
Surface modification strategies that take advantage of the passivation effects of albumin are important in the development of biomaterial surfaces. In this study, linear peptides (LP1, LP2) and a small chemical ligand (SCL) with albumin binding affinities were grafted onto silane functionalized silicon substrates. Surfaces were characterized with contact angle and ellipsometric measurements, and densities of immobilized ligands were assessed spectroscopically. Ellipsometrically measured thickness correlated with the predicted molecular lengths of grafted moieties. Contact angle analysis indicated that the LP1 and LP2 functionalized surfaces were hydrophilic compared to SCL functionalized and control surfaces. Adsorption of albumin from human serum was evaluated and quantified via specific enzyme-linked immunosorbent assays and 2D gel electrophoresis. The following trend was noted for surface adsorbed albumin: LP1 > LP2 > SCL > C, with LP1 derivatized surfaces having ~2.450 μg/cm(2) of bound albumin. LP1 derivatized surfaces possessed the least number of adsorbed platelets with rounded platelet morphology when compared to control surface.
Collapse
Affiliation(s)
- Sanjukta Guha Thakurta
- Department of Chemical and Biomolecular Engineering, University of Nebraska, Lincoln, NE 68588, USA
| | | |
Collapse
|
31
|
Jones KS. Assays on the influence of biomaterials on allogeneic rejection in tissue engineering. TISSUE ENGINEERING PART B-REVIEWS 2009; 14:407-17. [PMID: 18826337 DOI: 10.1089/ten.teb.2008.0264] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
In tissue engineering, innate responses to biomaterial scaffolds will affect rejection of allogeneic cells. Biomaterials directly influence innate and adaptive immune cell adhesion, reactive oxygen intermediate production, cytokine secretion, nuclear factor-kappa B nuclear translocation, gene expression, and cell surface markers, all of which are likely to affect allogeneic rejection responses. A major goal in tissue engineering is to induce transplant tolerance, potentially by manipulating the biomaterial component. This review describes methods of measuring responses of macrophages, dendritic cells, and T cells stimulated in vitro and in vivo and addresses key factors in assay development. Such tests include mixed leukocyte reactions, enzyme-linked immunosorbent spot assays, trans-vivo delayed-type hypersensitivity assays, and measurement of dendritic cell subsets and anti-donor antibodies; we propose extending these studies to tissue engineering.
Collapse
Affiliation(s)
- Kim S Jones
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada.
| |
Collapse
|
32
|
Tan J, Brash J. Nonfouling biomaterials based on polyethylene oxide-containing amphiphilic triblock copolymers as surface modifying additives: Adsorption of proteins from human plasma to copolymer/polyurethane blends. J Biomed Mater Res A 2009; 90:196-204. [DOI: 10.1002/jbm.a.32074] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
33
|
Chen H, Yuan L, Song W, Wu Z, Li D. Biocompatible polymer materials: Role of protein–surface interactions. Prog Polym Sci 2008. [DOI: 10.1016/j.progpolymsci.2008.07.006] [Citation(s) in RCA: 452] [Impact Index Per Article: 28.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
34
|
Chen H, Wang L, Zhang Y, Li D, McClung WG, Brook MA, Sheardown H, Brash JL. Fibrinolytic Poly(dimethyl siloxane) Surfaces. Macromol Biosci 2008; 8:863-70. [DOI: 10.1002/mabi.200800014] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
35
|
Du YJ, Brash JL, McClung G, Berry LR, Klement P, Chan AKC. Protein adsorption on polyurethane catheters modified with a novel antithrombin-heparin covalent complex. J Biomed Mater Res A 2007; 80:216-25. [PMID: 17072855 DOI: 10.1002/jbm.a.30977] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Highly anticoagulant covalent antithrombin-heparin complex (ATH) was covalently grafted onto polyurethane catheters to suppress adsorption/activation of procoagulant proteins and enhance adsorption/activation of anticoagulant proteins for blood compatibility. Consistency of catheter coating was demonstrated using immunohistochemical visualization of ATH. The ability of the resulting immobilized ATH heparin chains to bind antithrombin (AT) from plasma, as measured by binding of (125)I-radiolabeled AT, was greater than that for commercially-available heparin-coated catheters, and much greater than for uncoated catheters. Complementary measurements of antifactor Xa (FXa) activity and plasma protein binding were also performed. Both ATH-coated and heparin-coated catheters demonstrated functional binding of exogenous AT. However, the ATH-coated catheters gave a trend towards elevated anti- FXa activities/AT binding ratios, consistent with the higher active pentasaccharide content in starting ATH. Western blot analysis of proteins adsorbed to catheters after incubation with rabbit plasma established protein binding profiles that showed AT and albumin as major plasma proteins adsorbed to ATH-coated catheters, while AT and altered forms of fibrinogen were major plasma protein species adsorbed to heparinized catheters.
Collapse
Affiliation(s)
- Ying Jun Du
- The Henderson Research Centre, McMaster University, 711 Concession Street, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
36
|
Lee CCI, Ye F, Tarantal AF. Comparison of growth and differentiation of fetal and adult rhesus monkey mesenchymal stem cells. Stem Cells Dev 2006; 15:209-20. [PMID: 16646667 DOI: 10.1089/scd.2006.15.209] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The goal of this study was to compare the growth and differentiation potential of fetal and adult rhesus monkey (Macaca mulatta) mesenchymal stem cells (rhMSCs). rhMSCs were obtained from healthy early third-trimester fetal (n = 3) and adult (n = 3) rhesus monkey bone marrow. Fetal rhMSCs were plated at 10, 50, 100, or 1,000 cells/cm(2) in medium containing 10% or 20% infant monkey serum (IMS) or fetal bovine serum (FBS). Fetal rhMSCs grown at 1,000 cells/cm(2) in 20% FBS showed faster growth rates and differentiation toward adipogenic, chondrogenic, and osteogenic lineages when compared to other culture conditions and to adult cells (p < 0.05). Fetal rhMSC showed higher population doubling times (11.3 +/- 0.5) when compared to adult cells (7.3 +/- 0.8) during the first three passages. Adult rhMSC did not grow beyond the third passage under all culture conditions, including those supplemented with insulin-like growth factor (IGF)-I, IGF-II, platelet-derived growth factor (PDGF), and fibroblast growth factor-2 (FGF-2). After the third passage, adult rhMSC cultures were observed with large syncytia and with evidence of apoptosis. Cells obtained from these cultures tested positive for simian foamy virus (SFV) by PCR, RT-PCR, and immunofluorescent assay. Adult rhMSCs cultured with 10 microM tenofovir, an antiviral agent, showed normal growth and differentiation for over 20 population doublings. These findings suggest that: (1) fetal rhMSCs possess greater self-renewal and differentiation potential when compared to adult cells; and (2) SFV can inhibit proliferation of adult rhMSCs in culture, whereas the addition of tenofovir can successfully suppress SFV replication in vitro and result in resumed growth.
Collapse
Affiliation(s)
- C Chang I Lee
- California National Primate Research Center, University of California, Davis, 95616, USA
| | | | | |
Collapse
|
37
|
Göppert TM, Müller RH. Adsorption kinetics of plasma proteins on solid lipid nanoparticles for drug targeting. Int J Pharm 2005; 302:172-86. [PMID: 16098695 DOI: 10.1016/j.ijpharm.2005.06.025] [Citation(s) in RCA: 152] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2004] [Revised: 06/06/2005] [Accepted: 06/14/2005] [Indexed: 11/22/2022]
Abstract
The interactions of intravenously injected carriers with plasma proteins are the determining factor for the in vivo fate of the particles. In this study the adsorption kinetics on solid lipid nanoparticles (SLN) were investigated and compared to the adsorption kinetics on previously analyzed polymeric model particles and O/W-emulsions. The adsorbed proteins were determined using two-dimensional polyacrylamide gel electrophoresis (2-DE). Employing diluted human plasma, a transient adsorption of fibrinogen was observed on the surface of SLN stabilized with the surfactant Tego Care 450, which in plasma of higher concentrations was displaced by apolipoproteins. This was in agreement with the "Vroman-effect" previously determined on solid surfaces. It says that in the early stages of adsorption, more plentiful proteins with low affinity are displaced by less plentiful with higher affinity to the surface. Over a period of time (0.5 min to 4 h) more interesting for the organ distribution of long circulating carriers, no relevant changes in the composition of the adsorption patterns of SLN, surface-modified with poloxamine 908 and poloxamer 407, respectively, were detected. This is in contrast to the chemically similar surface-modified polymeric particles but well in agreement with the surface-modified O/W-emulsions. As there is no competitive displacement of apolipoproteins on these modified SLN, the stable adsorption patterns may be better exploited for drug targeting than particles with an adsorption pattern being very dependent on contact time with plasma.
Collapse
Affiliation(s)
- T M Göppert
- The Free University of Berlin, Institute of Pharmacy, Department of Pharmaceutical Technology, Biotechnology and Quality Management, Kelchstr. 31, 12169 Berlin, Germany
| | | |
Collapse
|
38
|
Unsworth LD, Sheardown H, Brash JL. Polyethylene oxide surfaces of variable chain density by chemisorption of PEO-thiol on gold: adsorption of proteins from plasma studied by radiolabelling and immunoblotting. Biomaterials 2005; 26:5927-33. [PMID: 15958239 DOI: 10.1016/j.biomaterials.2005.03.010] [Citation(s) in RCA: 129] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2005] [Accepted: 03/09/2005] [Indexed: 11/26/2022]
Abstract
The mechanisms involved in the inhibition of protein adsorption by polyethylene oxide (PEO) are not completely understood, but it is believed that PEO chain length, chain density and chain conformation all play a role. In this work, surfaces formed by chemisorption of PEO-thiol to gold were investigated: the effects of PEO chain density, chain length (600, 750, 2000 and 5000 MW) and end-group (-OH, -OCH3) on protein adsorption from plasma are reported. Similar to previous single protein adsorption studies (L.D. Unsworth et al., Langmuir 2005;21:1036-41) it was found that, of the different surfaces investigated, PEO layers formed from solutions near the cloud point adsorbed the lowest amount of fibrinogen from plasma. Layers of hydroxyl-terminated PEO of MW 600 formed under these low solubility conditions showed almost complete suppression (versus controls) of the Vroman effect, with 20+/-1 ng/cm2 adsorbed fibrinogen at the Vroman peak and 6.7+/-0.6 ng/cm2 at higher plasma concentration. By comparison, Vroman peak adsorption was 70+/-20 and 50+/-3 ng/cm2, respectively, for 750-OCH3 and 2000-OCH3 layers formed under low solubility conditions; adsorption on these surfaces at higher plasma concentration was 16+/-9 and 12+/-3 ng/cm2. Thus in addition to the effect of solution conditions noted previously, the results of this study also suggest a chain end group effect which inhibits fibrinogen adsorption to, and/or facilitates displacement from, hydroxyl terminated PEO layers. Fibrinogen adsorption from plasma was not significantly different for surfaces prepared with PEO of molecular weight 750 and 2000 when the chain density was the same ( approximately 0.5 chains/nm2) supporting the conclusion that chain density may be the key property for suppression of protein adsorption. The proteins eluted from the surfaces after contact with plasma were investigated by SDS-PAGE and immunoblotting. A number of proteins were detected on the various surfaces including fibrinogen, albumin, C3 and apolipoprotein A-I. The blot responses were zero or weak for all four proteins of the contact system; some complement activation was observed on all of the surfaces studied.
Collapse
Affiliation(s)
- Larry D Unsworth
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ont., Canada L8S 4L7
| | | | | |
Collapse
|
39
|
Kim JK, Scott EA, Elbert DL. Proteomic analysis of protein adsorption: Serum amyloid P adsorbs to materials and promotes leukocyte adhesion. J Biomed Mater Res A 2005; 75:199-209. [PMID: 16082704 DOI: 10.1002/jbm.a.30424] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Serum and plasma protein adsorption on materials was analyzed using gel electrophoresis and ion trap mass spectrometry. Following incubation of polypropylene, polyethylene terephthalate (PET), or polydimethylsiloxane (PDMS) with 5% serum for longer than 4 h, we found unexpectedly high amounts of the pentraxin serum amyloid P. It was previously shown that serum amyloid P is constitutively expressed in humans, functions as an opsonin, and interacts with the Fcgamma receptors on leukocytes. We demonstrate that serum amyloid P adsorbed to tissue culture polystyrene, PDMS, and PET promotes the adhesion of granulocytes and monocytes in the presence of calcium. The methods developed for these studies may be useful for the large-scale study of protein adsorption and do not rely on radiolabeling or the availability of antibodies.
Collapse
Affiliation(s)
- Jin-Ku Kim
- Department of Chemical Engineering, Washington University, St. Louis, MS 63130, USA
| | | | | |
Collapse
|
40
|
Shen F, Li AA, Cornelius RM, Cirone P, Childs RF, Brash JL, Chang PL. Biological properties of photocrosslinked alginate microcapsules. J Biomed Mater Res B Appl Biomater 2005; 75:425-34. [PMID: 16035031 DOI: 10.1002/jbm.b.30323] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
An alternative form of gene therapy using recombinant cell lines delivering therapeutic products encapsulated in alginate hydrogel has proven effective in treating many murine models. The lack of long-term capsule stability has led to a new strategy to reinforce the microcapsules with a photopolymerized interpenetrating covalent network of N-vinylpyrrolidone (NVP) and sodium acrylate. Here the properties for potential application in gene therapy are reported. In assessing potential toxicity of the unpolymerized residues, HPLC showed that even after 1 week of washing, no toxic monomers could be detected. Their ability to sustain cell growth was monitored with growth of the encapsulated cells in vitro and in vivo. Although the initial photopolymerization caused significant cell damage, the cells were able to recover normal growth rates thereafter. After implanting into mice, the NVP-modified capsules showed a high level of biocompatibility as measured by hematological and biochemical functional tests. There was also no difference in the amount and type of plasma proteins adsorbing to the NVP-modified and the classical alginate capsules, thus indicating their similar biological compatibility. Both in vitro and in vivo tests confirmed that the NVP-modified capsules were more resistant to osmotic stress than the alginate microcapsules. Furthermore, when applied to the treatment of a murine model of human cancer by delivering encapsulated cells secreting angiostatin, the NVP-modified microcapsules suppressed tumor growth as successfully as the regular alginate microcapsules. In conclusion, the covalently modified microcapsules have shown a high level of biocompatibility, safety, increase in stability, and clinical efficacy for use as immunoisolation devices in gene therapy.
Collapse
Affiliation(s)
- Feng Shen
- Department of Pediatrics, McMaster University, Hamilton, Ontario, Canada
| | | | | | | | | | | | | |
Collapse
|
41
|
Abstract
Monofunctional poly(ethylene oxide) polymers of molecular weight (MW) 350, 750, and 2000, respectively, were modified with Si(OEt)3 groups. These polymers underwent classic condensation cure with hydroxy-terminated silicone polymers and Si(OEt)4 to give composites with poly(ethylene oxide) (PEO) rich surfaces under aqueous conditions, as shown by contact angle and XPS data. The hydrophobicity of the surfaces was considerably higher in air. The greatest PEO concentration was observed with relatively short chain polymers of MW 350. Silicone polymers bearing short chain PEO chains were also observed to be the most protein rejecting from either buffer (fibrinogen) (90%) or plasma (85%). The silicone/TES-MPEO formulation offers the advantage of a one step/one shot polymerization process that gives materials with a high protein rejection ability than can be cast as films, or molded into complex shapes. Covalently linked PEO films of a variety of chain lengths and total surface coverage can be readily accommodated.
Collapse
Affiliation(s)
- Hong Chen
- Department of Chemistry, McMaster University, Hamilton, ON, Canada L8S 4L7
| | | | | |
Collapse
|
42
|
van Raamsdonk JM, Cornelius RM, Brash JL, Chang PL. Deterioration of polyamino acid-coated alginate microcapsules in vivo. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2003; 13:863-84. [PMID: 12463508 DOI: 10.1163/156856202320401933] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The implantation of immuno-isolated recombinant cell lines secreting a therapeutic protein in alginate microcapsules presents an alternative approach to gene therapy. Its clinical efficacy has recently been demonstrated in treating several genetic diseases in murine models. However, its application to humans will depend on the long-term structural stability of the microcapsules. Based on previous implantations in canines, it appears that survival of alginate-poly-L-lysine-alginate microcapsules in such large animals is short-lived. This article reports on the biological factors that may have contributed to the degradation of these microcapsules after implantation in dogs. Alginate microcapsules coated with poly-L-lysine or poly-L-arginine were implanted in subcutaneous or intraperitoneal sites. The retrieved microcapsules showed a loss of mechanical stability, as measured by resistance to osmotic stress. The polyamino acid coats were rendered fragile and easily lost, particularly when poly-L-lysine was used for coating and the intraperitoneal site was used for implantation. Various plasma proteins were associated with the retrieved microcapsules and identified with western blotting to include Factor XI, Factor XII, prekallikrein, HMWK, fibrinogen, plasminogen, ATIII, transferrin, alpha-1-antitrypsin, fibronectin, IgG, alpha-2-macroglobulin, vitronectin, prothrombin, apolipoprotein A1, and particularly albumin, a major Ca-transporting plasma protein. Complement proteins (C3, Factor B, Factor H, Factor I) and C3 activation fragments were detected. Release of the amino acids from the microcapsule polyamino acid coats was observed after incubation with plasma. indicating the occurrence of proteolytic degradation. Hence, the loss of long-term stability of the polyamino acid-coated alginate microcapsules is associated with activation of the complement system, degradation of the polyamino acid coating, and destabilization of the alginate core matrix, probably through loss of calcium-mediated ionic cross-linking of the guluronic acid polymers in the alginate. These destructive forces may be slightly mitigated by using poly-L-arginine instead of poly-L-lysine for coating and by implanting in a subcutaneous instead of an intraperitoneal site. However, the long-term stability of such devices may require significant improvements in the microcapsule polymer chemistry to withstand such biological impediments.
Collapse
Affiliation(s)
- J M van Raamsdonk
- Department of Medical Sciences, Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | | | | |
Collapse
|