Chen G, Wang CY, Ma Z, Yi HL, Bi NM, Zhu WJ, Han J, Lu SL, Zhang SS, Shen H, Zhang WH, Zhang P, Si Y. A prospective and consecutive study assessing short-term clinical and radiographic outcomes of Chinese domestically manufactured 3D printing trabecular titanium acetabular cup for primary total hip arthroplasty: evaluation of 236 cases. Front Surg 2024; 11:1279194. [PMID: 38601877 PMCID: PMC11004300 DOI: 10.3389/fsurg.2024.1279194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Accepted: 03/11/2024] [Indexed: 04/12/2024] Open
Abstract
Purpose We prospectively evaluate the short-term clinical and radiographic outcomes of the only Chinese domestically produced trabecular titanium acetabular cup(3D ACT™ cup) in primary total hip arthroplasty (THA), aiming to provide evidence-based support for its clinical application. Methods A total of 236 patients, who underwent primary THA using 3D ACT™ cup in the Department of Joint Surgery at our hospital between January 2017 and June 2019, were included in this study. General patient data, imaging information, functional scores, and complications were collected to evaluate the early clinical efficacy. Results All patients were followed up for 33-52 months, with an average of (42.2 ± 9.2) months. At the last follow-up, the preoperative HHS score increased significantly from 43.7 ± 6.8 to 85.6 ± 9.3 points (P < 0.01). Similarly, the preoperative WOMAC scores showed significant improvement from 59.2 ± 5.8 to 13.1 ± 3.5 points (P < 0.01). 92.3% of the patients expressed satisfaction or high satisfaction with the clinical outcome. Furthermore, 87.7% of the acetabular cups were positioned within the Lewinnek safe zone, achieving successful reconstruction of the acetabular rotation center. The cup survival rate at the last follow-up was 100%. Conclusions The utilization of the only Chinese domestically manufactured 3D printing trabecular titanium acetabular cup in primary THA demonstrated favorable short-term clinical and radiographic outcomes. The acetabular cup exhibits excellent initial stability, high survival rate, and favorable osseointegration, leading to a significant enhancement in pain relief and functional improvement. In the future, larger sample sizes and multicenter prospective randomized controlled trials will be required to validate the long-term safety and effectiveness of this 3D ACT™ cup.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | - Yan Si
- Department of Geriatric Orthopedics, Sichuan Provincial Orthopedic Hospital, Chengdu, Sichuan, China
| |
Collapse
|
2
|
Li H, Hao J, Liu X. Research progress and perspective of metallic implant biomaterials for craniomaxillofacial surgeries. Biomater Sci 2024; 12:252-269. [PMID: 38170634 DOI: 10.1039/d2bm01414a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
Craniomaxillofacial bone serves a variety of functions. However, the increasing number of cases of craniomaxillofacial bone injury and the use of selective rare implants make the treatment difficult, and the cure rate is low. If such a bone injury is not properly treated, it can lead to a slew of complications that can seriously disrupt a patient's daily life. For example, premature closure of cranial sutures or skull fractures can lead to increased intracranial pressure, which can lead to headaches, vomiting, and even brain hernia. At present, implant placement is one of the most common approaches to repair craniomaxillofacial bone injury or abnormal closure, especially with biomedical metallic implants. This review analyzes the research progress in the design and development of degradable and non-degradable metallic implants in craniomaxillofacial surgery. The mechanical properties, corrosion behaviours, as well as in vitro and in vivo performances of these materials are summarized. The challenges and future research directions of metallic biomaterials used in craniomaxillofacial surgery are also identified.
Collapse
Affiliation(s)
- Huafang Li
- School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China.
| | - Jiaqi Hao
- School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China.
| | - Xiwei Liu
- Lepu Medical Technology Co., Ltd, Beijing 102200, China
| |
Collapse
|
3
|
Hijazi KM, Dixon SJ, Armstrong JE, Rizkalla AS. Titanium Alloy Implants with Lattice Structures for Mandibular Reconstruction. MATERIALS (BASEL, SWITZERLAND) 2023; 17:140. [PMID: 38203994 PMCID: PMC10779528 DOI: 10.3390/ma17010140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/30/2023] [Accepted: 12/19/2023] [Indexed: 01/12/2024]
Abstract
In recent years, the field of mandibular reconstruction has made great strides in terms of hardware innovations and their clinical applications. There has been considerable interest in using computer-aided design, finite element modelling, and additive manufacturing techniques to build patient-specific surgical implants. Moreover, lattice implants can mimic mandibular bone's mechanical and structural properties. This article reviews current approaches for mandibular reconstruction, their applications, and their drawbacks. Then, we discuss the potential of mandibular devices with lattice structures, their development and applications, and the challenges for their use in clinical settings.
Collapse
Affiliation(s)
- Khaled M. Hijazi
- School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 3K7, Canada
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
| | - S. Jeffrey Dixon
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON N6A 5C1, Canada
| | - Jerrold E. Armstrong
- Division of Oral and Maxillofacial Surgery, Department of Otolaryngology Head and Neck Surgery, Henry Ford Hospital, Detroit, MI 48202, USA
| | - Amin S. Rizkalla
- School of Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 3K7, Canada
- Bone and Joint Institute, The University of Western Ontario, London, ON N6G 2V4, Canada
- Schulich School of Medicine & Dentistry, The University of Western Ontario, London, ON N6A 5C1, Canada
- Chemical and Biochemical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 5B9, Canada
| |
Collapse
|
4
|
Marin E. Forged to heal: The role of metallic cellular solids in bone tissue engineering. Mater Today Bio 2023; 23:100777. [PMID: 37727867 PMCID: PMC10506110 DOI: 10.1016/j.mtbio.2023.100777] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 08/21/2023] [Accepted: 08/23/2023] [Indexed: 09/21/2023] Open
Abstract
Metallic cellular solids, made of biocompatible alloys like titanium, stainless steel, or cobalt-chromium, have gained attention for their mechanical strength, reliability, and biocompatibility. These three-dimensional structures provide support and aid tissue regeneration in orthopedic implants, cardiovascular stents, and other tissue engineering cellular solids. The design and material chemistry of metallic cellular solids play crucial roles in their performance: factors such as porosity, pore size, and surface roughness influence nutrient transport, cell attachment, and mechanical stability, while their microstructure imparts strength, durability and flexibility. Various techniques, including additive manufacturing and conventional fabrication methods, are utilized for producing metallic biomedical cellular solids, each offering distinct advantages and drawbacks that must be considered for optimal design and manufacturing. The combination of mechanical properties and biocompatibility makes metallic cellular solids superior to their ceramic and polymeric counterparts in most load bearing applications, in particular under cyclic fatigue conditions, and more in general in application that require long term reliability. Although challenges remain, such as reducing the production times and the associated costs or increasing the array of available materials, metallic cellular solids showed excellent long-term reliability, with high survival rates even in long term follow-ups.
Collapse
Affiliation(s)
- Elia Marin
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585, Kyoto, Japan
- Department of Dental Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, Kyoto, 602-8566, Japan
- Department Polytechnic of Engineering and Architecture, University of Udine, 33100, Udine, Italy
- Biomedical Research Center, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, Kyoto, 606-8585, Japan
| |
Collapse
|
5
|
Li L, Wang P, Liang H, Jin J, Zhang Y, Shi J, Zhang Y, He S, Mao H, Xue B, Lai J, Zhu L, Jiang Q. Design of a Haversian system-like gradient porous scaffold based on triply periodic minimal surfaces for promoting bone regeneration. J Adv Res 2023; 54:89-104. [PMID: 36632888 DOI: 10.1016/j.jare.2023.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 09/14/2022] [Accepted: 01/06/2023] [Indexed: 01/09/2023] Open
Abstract
INTRODUCTION The bone ingrowth depth in the porous scaffolds is greatly affected by the structural design, notably the pore size, pore geometry, and the pore distribution. To enhance the bone regeneration capability of scaffolds, the bionic design can be regarded as a potential solution. OBJECTIVES We proposed a Haversian system-like gradient structure based on the triply periodic minimal surface architectures with pore size varying from the edge to the center. And its effects in promoting bone regeneration were evaluated in the study. METHODS The gradient scaffold was designed using the triply periodic minimal surface architectures. The mechanical properties were analyzed by the finite element simulation and confirmed using the universal machine. The fluid characteristics were calculated by the computational fluid dynamics analysis. The bone regeneration process was simulated using a in silico computational model containing the main biological, physical, and chemical variation during the bone growth process. Finally, the in vitro and in vivo studies were carried out to verify the actual osteogenic effect. RESULTS Compared to the uniform scaffold, the biomimetic gradient scaffold demonstrated better performance in stress conduction and reduced stress shielding effects. The fluid features were appropriate for cell migration and flow diffusion, and the permeability was in the same order of magnitude with the natural bone. The bone ingrowth simulation exhibited improved angiogenesis and bone regeneration. Higher expression of the osteogenesis-related genes, higher alkaline phosphatase activity, and increased mineralization could be observed on the gradient scaffold in the in vitro study. The 12-week in vivo study proved that the gradient scaffold had deeper bone inserting depth and a more stable bone-scaffold interface. CONCLUSION The Haversian system-like gradient structure can effectively promote the bone regeneration. This structural design can be used as a new solution for the clinical application of prosthesis design.
Collapse
Affiliation(s)
- Lan Li
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Branch of National Clinical Research Center for Orthopedics, Drum Tower Hospital Affiliated to Medical School of Nanjing University, No. 321 Zhongshan Road, Nanjing 210000, China; Jiangsu Engineering Research Center for 3D Bioprinting, No. 321 Zhongshan Road, Nanjing 210000, China
| | - Peng Wang
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Branch of National Clinical Research Center for Orthopedics, Drum Tower Hospital Affiliated to Medical School of Nanjing University, No. 321 Zhongshan Road, Nanjing 210000, China; Jiangsu Engineering Research Center for 3D Bioprinting, No. 321 Zhongshan Road, Nanjing 210000, China
| | - Huixin Liang
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Branch of National Clinical Research Center for Orthopedics, Drum Tower Hospital Affiliated to Medical School of Nanjing University, No. 321 Zhongshan Road, Nanjing 210000, China; Jiangsu Engineering Research Center for 3D Bioprinting, No. 321 Zhongshan Road, Nanjing 210000, China
| | - Jing Jin
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Branch of National Clinical Research Center for Orthopedics, Drum Tower Hospital Affiliated to Medical School of Nanjing University, No. 321 Zhongshan Road, Nanjing 210000, China
| | - Yibo Zhang
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Branch of National Clinical Research Center for Orthopedics, Drum Tower Hospital Affiliated to Medical School of Nanjing University, No. 321 Zhongshan Road, Nanjing 210000, China
| | - Jianping Shi
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Branch of National Clinical Research Center for Orthopedics, Drum Tower Hospital Affiliated to Medical School of Nanjing University, No. 321 Zhongshan Road, Nanjing 210000, China
| | - Yun Zhang
- State Key Laboratory of Bioelectronics, School of Biological Science & Medical Engineering, Southeast University, No. 2 Sipailou, Nanjing 210096, China
| | - Siyuan He
- State Key Laboratory of Bioelectronics, School of Biological Science & Medical Engineering, Southeast University, No. 2 Sipailou, Nanjing 210096, China
| | - Hongli Mao
- College of Materials Science and Engineering, Nanjing Tech University, No. 30 South Puzhu Road, Nanjing 211816, China
| | - Bin Xue
- National Laboratory of Solid State Microstructures, Department of Physics, Nanjing University, No. 2 Hankou Road, Nanjing 210093, China
| | - Jiancheng Lai
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305-6104, USA
| | - Liya Zhu
- School of Electrical and Automation Engineering, Nanjing Normal University, No.2 Xuelin Road, Nanjing 210023, China.
| | - Qing Jiang
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Branch of National Clinical Research Center for Orthopedics, Drum Tower Hospital Affiliated to Medical School of Nanjing University, No. 321 Zhongshan Road, Nanjing 210000, China; Jiangsu Engineering Research Center for 3D Bioprinting, No. 321 Zhongshan Road, Nanjing 210000, China.
| |
Collapse
|
6
|
Zhou J, See CW, Sreenivasamurthy S, Zhu D. Customized Additive Manufacturing in Bone Scaffolds-The Gateway to Precise Bone Defect Treatment. RESEARCH (WASHINGTON, D.C.) 2023; 6:0239. [PMID: 37818034 PMCID: PMC10561823 DOI: 10.34133/research.0239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 09/07/2023] [Indexed: 10/12/2023]
Abstract
In the advancing landscape of technology and novel material development, additive manufacturing (AM) is steadily making strides within the biomedical sector. Moving away from traditional, one-size-fits-all implant solutions, the advent of AM technology allows for patient-specific scaffolds that could improve integration and enhance wound healing. These scaffolds, meticulously designed with a myriad of geometries, mechanical properties, and biological responses, are made possible through the vast selection of materials and fabrication methods at our disposal. Recognizing the importance of precision in the treatment of bone defects, which display variability from macroscopic to microscopic scales in each case, a tailored treatment strategy is required. A patient-specific AM bone scaffold perfectly addresses this necessity. This review elucidates the pivotal role that customized AM bone scaffolds play in bone defect treatment, while offering comprehensive guidelines for their customization. This includes aspects such as bone defect imaging, material selection, topography design, and fabrication methodology. Additionally, we propose a cooperative model involving the patient, clinician, and engineer, thereby underscoring the interdisciplinary approach necessary for the effective design and clinical application of these customized AM bone scaffolds. This collaboration promises to usher in a new era of bioactive medical materials, responsive to individualized needs and capable of pushing boundaries in personalized medicine beyond those set by traditional medical materials.
Collapse
Affiliation(s)
- Juncen Zhou
- Department of Biomedical Engineering,
Stony Brook University, Stony Brook, NY, USA
| | - Carmine Wang See
- Department of Biomedical Engineering,
Stony Brook University, Stony Brook, NY, USA
| | - Sai Sreenivasamurthy
- Department of Biomedical Engineering,
Stony Brook University, Stony Brook, NY, USA
| | - Donghui Zhu
- Department of Biomedical Engineering,
Stony Brook University, Stony Brook, NY, USA
| |
Collapse
|
7
|
Gong T, Lu M, Wang J, Zhang Y, Wang Y, Tang F, Li Z, Zhou Y, Min L, Luo Y, Tu C. 3D-Printed Modular Endoprosthesis Reconstruction Following Total Calcanectomy in Calcaneal Malignancy. Foot Ankle Int 2023; 44:1021-1029. [PMID: 37542414 DOI: 10.1177/10711007231185334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/07/2023]
Abstract
BACKGROUND The use of 3D-printed endoprosthesis has been proposed as a viable limb-salvage procedure following total calcanectomy in patients with calcaneal malignancy. However, certain drawbacks persist concerning the prosthetic design. In this case series, we designed a modular endoprosthesis incorporating a novel drainage system, aiming to improve the functional outcomes and to promote wound healing. METHODS We retrospectively analyzed patients with calcaneal malignancy who underwent 3D-printed modular endoprosthesis reconstruction. Clinically, we evaluated functional outcomes using the 10-cm visual analog scale (VAS) score, the 1993 version of the Musculoskeletal Tumor Society (MSTS-93) score, and the American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot score. Complications were also recorded. RESULTS Five male patients met the final inclusion criteria. The median age was 20 years (range 13-47 years). The median follow-up time was 28 months (range, 13-65 months). Median postoperative functional MSTS-93, VAS, and AOFAS scores were 27 points (range, 25-29), 0 points (range, 0-1), and 86 points (range, 83-93), respectively. Wound healing was observed in all patients, and there were no complications related to the endoprosthesis at the last follow-up. CONCLUSION The use of 3D-printed modular endoprosthesis was associated with satisfactory short-term outcomes in patients undergoing calcaneal reconstruction. The incorporation of a novel design featuring an integrated draining system has the potential to enhance wound healing and expedite functional recovery. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
- Taojun Gong
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Minxun Lu
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Jie Wang
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Yuqi Zhang
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Yitian Wang
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Fan Tang
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Zhuangzhuang Li
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Yong Zhou
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Li Min
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Yi Luo
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| | - Chongqi Tu
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Model Worker and Craftsman Talent Innovation Workshop of Sichuan province, Chengdu, Sichuan, People's Republic of China
| |
Collapse
|
8
|
Wu Y, Liu J, Kang L, Tian J, Zhang X, Hu J, Huang Y, Liu F, Wang H, Wu Z. An overview of 3D printed metal implants in orthopedic applications: Present and future perspectives. Heliyon 2023; 9:e17718. [PMID: 37456029 PMCID: PMC10344715 DOI: 10.1016/j.heliyon.2023.e17718] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 06/12/2023] [Accepted: 06/26/2023] [Indexed: 07/18/2023] Open
Abstract
With the ability to produce components with complex and precise structures, additive manufacturing or 3D printing techniques are now widely applied in both industry and consumer markets. The emergence of tissue engineering has facilitated the application of 3D printing in the field of biomedical implants. 3D printed implants with proper structural design can not only eliminate the stress shielding effect but also improve in vivo biocompatibility and functionality. By combining medical images derived from technologies such as X-ray scanning, CT, MRI, or ultrasonic scanning, 3D printing can be used to create patient-specific implants with almost the same anatomical structures as the injured tissues. Numerous clinical trials have already been conducted with customized implants. However, the limited availability of raw materials for printing and a lack of guidance from related regulations or laws may impede the development of 3D printing in medical implants. This review provides information on the current state of 3D printing techniques in orthopedic implant applications. The current challenges and future perspectives are also included.
Collapse
Affiliation(s)
- Yuanhao Wu
- Medical Research Center, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Jieying Liu
- Medical Research Center, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Lin Kang
- Medical Research Center, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Jingjing Tian
- Medical Research Center, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Xueyi Zhang
- Medical Research Center, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Jin Hu
- Medical Research Center, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Yue Huang
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Fuze Liu
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Hai Wang
- Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Zhihong Wu
- Medical Research Center, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730, China
- Beijing Key Laboratory for Genetic Research of Bone and Joint Disease, Beijing, China
| |
Collapse
|
9
|
Toop N, Dhaliwal J, Grossbach A, Gibbs D, Reddy N, Keister A, Mallory N, Xu D, Viljoen S. Subsidence Rates Associated With Porous 3D-Printed Versus Solid Titanium Cages in Transforaminal Lumbar Interbody Fusion. Global Spine J 2023:21925682231157762. [PMID: 36786680 DOI: 10.1177/21925682231157762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/15/2023] Open
Abstract
STUDY DESIGN Retrospective Cohort Study. OBJECTIVE To determine whether 3D-printed porous titanium (3DPT) interbody cages offer any clinical or radiographic advantage over standard solid titanium (ST) interbody cages in transforaminal lumbar interbody fusions (TLIF). METHODS A consecutive series of adult patients undergoing one- or two-level TLIF with either 3DPT or ST "banana" cages were analyzed for patient reported outcome measures (PROMs), radiographic complications, and clinical complications. Exclusion criteria included clinical or radiographic follow-up less than 1 year. RESULTS The final cohort included 90 ST interbody levels from 74 patients, and 73 3DPT interbody levels from 50 patients for a total of 124 patients. Baseline demographic variables and comorbidity rates were similar between groups (P > .05). Subsidence of any grade occurred more frequently in the ST group compared with the 3DPT group (24.4% vs 5.5%, respectively, P = .001). Further, the ST group was more likely to have higher grades of subsidence than the 3DPT group (P = .009). All PROMs improved similarly after surgery and revision rates did not differ between groups (both P > .05). On multivariate analysis, significant positive correlators with increasing subsidence grade included greater age (P = .015), greater body mass index (P = .043), osteoporosis/osteopenia (P < .027), and ST cage type (P = .019). CONCLUSIONS When considering interbody material for TLIF, both ST and 3DPT cages performed well; however, 3DPT cages were associated with lower rates of subsidence. The clinical relevance of these findings deserves further randomized, prospective investigation.
Collapse
Affiliation(s)
- Nathaniel Toop
- Department of Neurosurgery, Ohio State University School of Medicine, Columbus, OH, USA
| | - Joravar Dhaliwal
- Department of Neurosurgery, Ohio State University School of Medicine, Columbus, OH, USA
| | - Andrew Grossbach
- Department of Neurosurgery, Ohio State University School of Medicine, Columbus, OH, USA
| | - David Gibbs
- Ohio State University School of Medicine, Columbus, OH, USA
| | - Nihaal Reddy
- Ohio State University School of Medicine, Columbus, OH, USA
| | | | - Noah Mallory
- Ohio State University School of Medicine, Columbus, OH, USA
| | - David Xu
- Department of Neurosurgery, Ohio State University School of Medicine, Columbus, OH, USA
| | - Stephanus Viljoen
- Department of Neurosurgery, Ohio State University School of Medicine, Columbus, OH, USA
| |
Collapse
|
10
|
Palmquist A, Jolic M, Hryha E, Shah FA. Complex geometry and integrated macro-porosity: Clinical applications of electron beam melting to fabricate bespoke bone-anchored implants. Acta Biomater 2023; 156:125-145. [PMID: 35675890 DOI: 10.1016/j.actbio.2022.06.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/16/2022] [Accepted: 06/01/2022] [Indexed: 01/18/2023]
Abstract
The last decade has witnessed rapid advancements in manufacturing technologies for biomedical implants. Additive manufacturing (or 3D printing) has broken down major barriers in the way of producing complex 3D geometries. Electron beam melting (EBM) is one such 3D printing process applicable to metals and alloys. EBM offers build rates up to two orders of magnitude greater than comparable laser-based technologies and a high vacuum environment to prevent accumulation of trace elements. These features make EBM particularly advantageous for materials susceptible to spontaneous oxidation and nitrogen pick-up when exposed to air (e.g., titanium and titanium-based alloys). For skeletal reconstruction(s), anatomical mimickry and integrated macro-porous architecture to facilitate bone ingrowth are undoubtedly the key features of EBM manufactured implants. Using finite element modelling of physiological loading conditions, the design of a prosthesis may be further personalised. This review looks at the many unique clinical applications of EBM in skeletal repair and the ground-breaking innovations in prosthetic rehabilitation. From a simple acetabular cup to the fifth toe, from the hand-wrist complex to the shoulder, and from vertebral replacement to cranio-maxillofacial reconstruction, EBM has experienced it all. While sternocostal reconstructions might be rare, the repair of long bones using EBM manufactured implants is becoming exceedingly frequent. Despite the various merits, several challenges remain yet untackled. Nevertheless, with the capability to produce osseointegrating implants of any conceivable shape/size, and permissive of bone ingrowth and functional loading, EBM can pave the way for numerous fascinating and novel applications in skeletal repair, regeneration, and rehabilitation. STATEMENT OF SIGNIFICANCE: Electron beam melting (EBM) offers unparalleled possibilities in producing contaminant-free, complex and intricate geometries from alloys of biomedical interest, including Ti6Al4V and CoCr. We review the diverse range of clinical applications of EBM in skeletal repair, both as mass produced off-the-shelf implants and personalised, patient-specific prostheses. From replacing large volumes of disease-affected bone to complex, multi-material reconstructions, almost every part of the human skeleton has been replaced with an EBM manufactured analog to achieve macroscopic anatomical-mimickry. However, various questions regarding long-term performance of patient-specific implants remain unaddressed. Directions for further development include designing personalised implants and prostheses based on simulated loading conditions and accounting for trabecular bone microstructure with respect to physiological factors such as patient's age and disease status.
Collapse
Affiliation(s)
- Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Martina Jolic
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Eduard Hryha
- Department of Materials and Manufacturing Technologies, Chalmers University of Technology, Gothenburg, Sweden
| | - Furqan A Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
11
|
Peng W, Liu Y, Wang C. Definition, measurement, and function of pore structure dimensions of bioengineered porous bone tissue materials based on additive manufacturing: A review. Front Bioeng Biotechnol 2023; 10:1081548. [PMID: 36686223 PMCID: PMC9845791 DOI: 10.3389/fbioe.2022.1081548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 12/16/2022] [Indexed: 01/05/2023] Open
Abstract
Bioengineered porous bone tissue materials based on additive manufacturing technology have gradually become a research hotspot in bone tissue-related bioengineering. Research on structural design, preparation and processing processes, and performance optimization has been carried out for this material, and further industrial translation and clinical applications have been implemented. However, based on previous studies, there is controversy in the academic community about characterizing the pore structure dimensions of porous materials, with problems in the definition logic and measurement method for specific parameters. In addition, there are significant differences in the specific morphological and functional concepts for the pore structure due to differences in defining the dimensional characterization parameters of the pore structure, leading to some conflicts in perceptions and discussions among researchers. To further clarify the definitions, measurements, and dimensional parameters of porous structures in bioengineered bone materials, this literature review analyzes different dimensional characterization parameters of pore structures of porous materials to provide a theoretical basis for unified definitions and the standardized use of parameters.
Collapse
Affiliation(s)
- Wen Peng
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, China,Foshan Orthopedic Implant (Stable) Engineering Technology Research Center, Foshan, China
| | - Yami Liu
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, China,Foshan Orthopedic Implant (Stable) Engineering Technology Research Center, Foshan, China
| | - Cheng Wang
- Department of Orthopaedic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, China,*Correspondence: Cheng Wang,
| |
Collapse
|
12
|
Park JW, Park H, Kim JH, Kim HM, Yoo CH, Kang HG. Fabrication of a lattice structure with periodic open pores through three-dimensional printing for bone ingrowth. Sci Rep 2022; 12:17223. [PMID: 36241776 PMCID: PMC9568544 DOI: 10.1038/s41598-022-22292-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 10/12/2022] [Indexed: 01/06/2023] Open
Abstract
Lattice structures for implants can be printed using metal three-dimensional (3D)-printing and used as a porous microstructures to enhance bone ingrowth as orthopedic implants. However, designs and 3D-printed products can vary. Thus, we aimed to investigate whether targeted pores can be consistently obtained despite printing errors. The cube-shaped specimen was printed with one side 15 mm long and a full lattice with a dode-thin structure of 1.15, 1.5, and 2.0 mm made using selective laser melting. Beam compensation was applied, increasing it until the vector was lost. For each specimen, the actual unit size and strut thickness were measured 50 times. Pore size was calculated from unit size and strut thickness, and porosity was determined from the specimen's weight. The actual average pore sizes for 1.15, 1.5, and 2.0 mm outputs were 257.9, 406.2, and 633.6 μm, and volume porosity was 62, 70, and 80%, respectively. No strut breakage or gross deformation was observed in any 3D-printed specimens, and the pores were uniformly fabricated with < 10% standard deviation. The actual micrometer-scaled printed structures were significantly different to the design, but this error was not random. Although the accuracy was low, precision was high for pore cells, so reproducibility was confirmed.
Collapse
Affiliation(s)
- Jong Woong Park
- grid.410914.90000 0004 0628 9810Orthopaedic Oncology Clinic, Center for Rare Cancers, National Cancer Center, Goyang-si, Gyeonggi-do Republic of Korea ,grid.410914.90000 0004 0628 9810Surgical Oncology branch, Division of Clinical Research, National Cancer Center, Goyang-si, Gyeonggi-do Republic of Korea
| | - Hyenmin Park
- grid.410914.90000 0004 0628 9810Surgical Oncology branch, Division of Clinical Research, National Cancer Center, Goyang-si, Gyeonggi-do Republic of Korea
| | - June Hyuk Kim
- grid.410914.90000 0004 0628 9810Orthopaedic Oncology Clinic, Center for Rare Cancers, National Cancer Center, Goyang-si, Gyeonggi-do Republic of Korea
| | | | | | - Hyun Guy Kang
- grid.410914.90000 0004 0628 9810Orthopaedic Oncology Clinic, Center for Rare Cancers, National Cancer Center, Goyang-si, Gyeonggi-do Republic of Korea
| |
Collapse
|
13
|
Al-Barqawi MO, Church B, Thevamaran M, Thoma DJ, Rahman A. Experimental Validation and Evaluation of the Bending Properties of Additively Manufactured Metallic Cellular Scaffold Structures for Bone Tissue Engineering. MATERIALS 2022; 15:ma15103447. [PMID: 35629475 PMCID: PMC9143386 DOI: 10.3390/ma15103447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 04/11/2022] [Accepted: 04/29/2022] [Indexed: 01/27/2023]
Abstract
The availability of additive manufacturing enables the fabrication of cellular bone tissue engineering scaffolds with a wide range of structural and architectural possibilities. The purpose of bone tissue engineering scaffolds is to repair critical size bone defects due to extreme traumas, tumors, or infections. This research study presented the experimental validation and evaluation of the bending properties of optimized bone scaffolds with an elastic modulus that is equivalent to the young’s modulus of the cortical bone. The specimens were manufactured using laser powder bed fusion technology. The morphological properties of the manufactured specimens were evaluated using both dry weighing and Archimedes techniques, and minor variations in the relative densities were observed in comparison with the computer-aided design files. The bending modulus of the cubic and diagonal scaffolds were experimentally investigated using a three-point bending test, and the results were found to agree with the numerical findings. A higher bending modulus was observed in the diagonal scaffold design. The diagonal scaffold was substantially tougher, with considerably higher energy absorption before fracture. The shear modulus of the diagonal scaffold was observed to be significantly higher than the cubic scaffold. Due to bending, the pores at the top side of the diagonal scaffold were heavily compressed compared to the cubic scaffold due to the extensive plastic deformation occurring in diagonal scaffolds and the rapid fracture of struts in the tension side of the cubic scaffold. The failure in struts in tension showed signs of ductility as necking was observed in fractured struts. Moreover, the fractured surface was observed to be rough and dull as opposed to being smooth and bright like in brittle fractures. Dimple fracture was observed using scanning electron microscopy as a result of microvoids emerging in places of high localized plastic deformation. Finally, a comparison of the mechanical properties of the studied BTE scaffolds with the cortical bone properties under longitudinal and transverse loading was investigated. In conclusion, we showed the capabilities of finite element analysis and additive manufacturing in designing and manufacturing promising scaffold designs that can replace bone segments in the human body.
Collapse
Affiliation(s)
- Mohammad O. Al-Barqawi
- Department of Civil and Environmental Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
- Correspondence:
| | - Benjamin Church
- Department of Material Science and Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
| | - Mythili Thevamaran
- Department of Material Science and Engineering, University of Wisconsin, Madison, WI 53706, USA; (M.T.); (D.J.T.)
| | - Dan J. Thoma
- Department of Material Science and Engineering, University of Wisconsin, Madison, WI 53706, USA; (M.T.); (D.J.T.)
| | - Adeeb Rahman
- Department of Civil and Environmental Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
| |
Collapse
|
14
|
Al-Barqawi MO, Church B, Thevamaran M, Thoma DJ, Rahman A. Design and Validation of Additively Manufactured Metallic Cellular Scaffold Structures for Bone Tissue Engineering. MATERIALS 2022; 15:ma15093310. [PMID: 35591643 PMCID: PMC9100147 DOI: 10.3390/ma15093310] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 04/28/2022] [Accepted: 04/29/2022] [Indexed: 11/24/2022]
Abstract
Bone-related defects that cannot heal without significant surgical intervention represent a significant challenge in the orthopedic field. The use of implants for these critical-sized bone defects is being explored to address the limitations of autograft and allograft options. Three-dimensional cellular structures, or bone scaffolds, provide mechanical support and promote bone tissue formation by acting as a template for bone growth. Stress shielding in bones is the reduction in bone density caused by the difference in stiffness between the scaffold and the surrounding bone tissue. This study aimed to reduce the stress shielding and introduce a cellular metal structure to replace defected bone by designing and producing a numerically optimized bone scaffold with an elastic modulus of 15 GPa, which matches the human’s cortical bone modulus. Cubic cell and diagonal cell designs were explored. Strut and cell dimensions were numerically optimized to achieve the desired structural modulus. The resulting scaffold designs were produced from stainless steel using laser powder bed fusion (LPBF). Finite element analysis (FEA) models were validated through compression testing of the printed scaffold designs. The structural configuration of the scaffolds was characterized with scanning electron microscopy (SEM). Cellular struts were found to have minimal internal porosity and rough surfaces. Strut dimensions of the printed scaffolds were found to have variations with the optimized computer-aided design (CAD) models. The experimental results, as expected, were slightly less than FEA results due to structural relative density variations in the scaffolds. Failure of the structures was stretch-dominated for the cubic scaffold and bending-dominated for the diagonal scaffold. The torsional and bending stiffnesses were numerically evaluated and showed higher bending and torsional moduli for the diagonal scaffold. The study successfully contributed to minimizing stress shielding in bone tissue engineering. The study also produced an innovative metal cellular structure that can replace large bone segments anywhere in the human body.
Collapse
Affiliation(s)
- Mohammad O. Al-Barqawi
- Department of Civil and Environmental Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
- Correspondence:
| | - Benjamin Church
- Department of Material Science and Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
| | - Mythili Thevamaran
- Department of Material Science and Engineering, University of Wisconsin, Madison, WI 53706, USA; (M.T.); (D.J.T.)
| | - Dan J. Thoma
- Department of Material Science and Engineering, University of Wisconsin, Madison, WI 53706, USA; (M.T.); (D.J.T.)
| | - Adeeb Rahman
- Department of Civil and Environmental Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
| |
Collapse
|
15
|
On-Growth and In-Growth Osseointegration Enhancement in PM Porous Ti-Scaffolds by Two Different Bioactivation Strategies: Alkali Thermochemical Treatment and RGD Peptide Coating. Int J Mol Sci 2022; 23:ijms23031750. [PMID: 35163682 PMCID: PMC8835960 DOI: 10.3390/ijms23031750] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 01/25/2022] [Accepted: 01/30/2022] [Indexed: 02/01/2023] Open
Abstract
A lack of primary stability and osteointegration in metallic implants may result in implant loosening and failure. Adding porosity to metallic implants reduces the stress shielding effect and improves implant performance, allowing the surrounding bone tissue to grow into the scaffold. However, a bioactive surface is needed to stimulate implant osteointegration and improve mechanical stability. In this study, porous titanium implants were produced via powder sintering to create different porous diameters and open interconnectivity. Two strategies were used to generate a bioactive surface on the metallic foams: (1) an inorganic alkali thermochemical treatment, (2) grafting a cell adhesive tripeptide (RGD). RGD peptides exhibit an affinity for integrins expressed by osteoblasts, and have been reported to improve osteoblast adhesion, whereas the thermochemical treatment is known to improve titanium implant osseointegration upon implantation. Bioactivated scaffolds and control samples were implanted into the tibiae of rabbits to analyze the effect of these two strategies in vivo regarding bone tissue regeneration through interconnected porosity. Histomorphometric evaluation was performed at 4 and 12 weeks after implantation. Bone-to-implant contact (BIC) and bone in-growth and on-growth were evaluated in different regions of interest (ROIs) inside and outside the implant. The results of this study show that after a long-term postoperative period, the RGD-coated samples presented higher quantification values of quantified newly formed bone tissue in the implant's outer area. However, the total analyzed bone in-growth was observed to be slightly greater in the scaffolds treated with alkali thermochemical treatment. These results suggest that both strategies contribute to enhancing porous metallic implant stability and osteointegration, and a combination of both strategies might be worth pursuing.
Collapse
|
16
|
Solórzano-Requejo W, Ojeda C, Díaz Lantada A. Innovative Design Methodology for Patient-Specific Short Femoral Stems. MATERIALS 2022; 15:ma15020442. [PMID: 35057160 PMCID: PMC8778668 DOI: 10.3390/ma15020442] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 01/01/2022] [Accepted: 01/04/2022] [Indexed: 12/18/2022]
Abstract
The biomechanical performance of hip prostheses is often suboptimal, which leads to problems such as strain shielding, bone resorption and implant loosening, affecting the long-term viability of these implants for articular repair. Different studies have highlighted the interest of short stems for preserving bone stock and minimizing shielding, hence providing an alternative to conventional hip prostheses with long stems. Such short stems are especially valuable for younger patients, as they may require additional surgical interventions and replacements in the future, for which the preservation of bone stock is fundamental. Arguably, enhanced results may be achieved by combining the benefits of short stems with the possibilities of personalization, which are now empowered by a wise combination of medical images, computer-aided design and engineering resources and automated manufacturing tools. In this study, an innovative design methodology for custom-made short femoral stems is presented. The design process is enhanced through a novel app employing elliptical adjustment for the quasi-automated CAD modeling of personalized short femoral stems. The proposed methodology is validated by completely developing two personalized short femoral stems, which are evaluated by combining in silico studies (finite element method (FEM) simulations), for quantifying their biomechanical performance, and rapid prototyping, for evaluating implantability.
Collapse
Affiliation(s)
- William Solórzano-Requejo
- Product Development Laboratory, Department of Mechanical Engineering, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
- Mechanical Technology Laboratory, Department of Mechanical and Electrical Engineering, Universidad de Piura, Piura 20009, Peru; or
- Correspondence: or (W.S.-R.); (A.D.L.)
| | - Carlos Ojeda
- Mechanical Technology Laboratory, Department of Mechanical and Electrical Engineering, Universidad de Piura, Piura 20009, Peru; or
| | - Andrés Díaz Lantada
- Product Development Laboratory, Department of Mechanical Engineering, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
- Correspondence: or (W.S.-R.); (A.D.L.)
| |
Collapse
|
17
|
Elhattab K, Hefzy MS, Hanf Z, Crosby B, Enders A, Smiczek T, Haghshenas M, Jahadakbar A, Elahinia M. Biomechanics of Additively Manufactured Metallic Scaffolds-A Review. MATERIALS (BASEL, SWITZERLAND) 2021; 14:6833. [PMID: 34832234 PMCID: PMC8625735 DOI: 10.3390/ma14226833] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 11/05/2021] [Accepted: 11/08/2021] [Indexed: 12/16/2022]
Abstract
This review paper is related to the biomechanics of additively manufactured (AM) metallic scaffolds, in particular titanium alloy Ti6Al4V scaffolds. This is because Ti6Al4V has been identified as an ideal candidate for AM metallic scaffolds. The factors that affect the scaffold technology are the design, the material used to build the scaffold, and the fabrication process. This review paper includes thus a discussion on the design of Ti6A4V scaffolds in relation to how their behavior is affected by their cell shapes and porosities. This is followed by a discussion on the post treatment and mechanical characterization including in-vitro and in-vivo biomechanical studies. A review and discussion are also presented on the ongoing efforts to develop predictive tools to derive the relationships between structure, processing, properties and performance of powder-bed additive manufacturing of metals. This is a challenge when developing process computational models because the problem involves multi-physics and is of multi-scale in nature. Advantages, limitations, and future trends in AM scaffolds are finally discussed. AM is considered at the forefront of Industry 4.0, the fourth industrial revolution. The market of scaffold technology will continue to boom because of the high demand for human tissue repair.
Collapse
Affiliation(s)
| | - Mohamed Samir Hefzy
- Department of Mechanical, Industrial & Manufacturing Engineering, College of Engineering, The University of Toledo, Toledo, OH 43606, USA; (K.E.); (Z.H.); (B.C.); (A.E.); (T.S.); (M.H.); (A.J.); (M.E.)
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Asbai-Ghoudan R, Ruiz de Galarreta S, Rodriguez-Florez N. Analytical model for the prediction of permeability of triply periodic minimal surfaces. J Mech Behav Biomed Mater 2021; 124:104804. [PMID: 34481309 DOI: 10.1016/j.jmbbm.2021.104804] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 07/22/2021] [Accepted: 08/27/2021] [Indexed: 12/22/2022]
Abstract
Triply periodic minimal surfaces (TPMS) are mathematically defined cellular structures whose geometry can be quickly adapted to target desired mechanical response (structural and fluid). This has made them desirable for a wide range of bioengineering applications; especially as bioinspired materials for bone replacement. The main objective of this study was to develop a novel analytical framework which would enable calculating permeability of TPMS structures based on the desired architecture, pore size and porosity. To achieve this, computer-aided designs of three TPMS structures (Fisher-Koch S, Gyroid and Schwarz P) were generated with varying cell size and porosity levels. Computational Fluid Dynamics (CFD) was used to calculate permeability for all models under laminar flow conditions. Permeability values were then used to fit an analytical model dependent on geometry parameters only. Results showed that permeability of the three architectures increased with porosity at different rates, highlighting the importance of pore distribution and architecture. The computed values of permeability fitted well with the suggested analytical model (R2>0.99, p<0.001). In conclusion, the novel analytical framework presented in the current study enables predicting permeability values of TPMS structures based on geometrical parameters within a difference <5%. This model, which could be combined with existing structural analytical models, could open new possibilities for the smart optimisation of TPMS structures for biomedical applications where structural and fluid flow properties need to be optimised.
Collapse
Affiliation(s)
- Reduan Asbai-Ghoudan
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain.
| | - Sergio Ruiz de Galarreta
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain
| | - Naiara Rodriguez-Florez
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain; IKERBASQUE, Basque Foundation for Science, Plaza Euskadi 5, 48009, Bilbao, Spain
| |
Collapse
|
19
|
Castagnini F, Caternicchia F, Biondi F, Masetti C, Faldini C, Traina F. Off-the-shelf 3D printed titanium cups in primary total hip arthroplasty. World J Orthop 2021; 12:376-385. [PMID: 34189075 PMCID: PMC8223718 DOI: 10.5312/wjo.v12.i6.376] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 04/02/2021] [Accepted: 05/22/2021] [Indexed: 02/06/2023] Open
Abstract
Three-dimensional (3D)-printed titanium cups used in primary total hip arthroplasty (THA) were developed to combine the benefits of a low elastic modulus with a highly porous surface. The aim was to improve local vascularization and bony ingrowth, and at the same time to reduce periprosthetic stress shielding. Additive manufacturing, starting with a titanium alloy powder, allows serial production of devices with large interconnected pores (trabecular titanium), overcoming the drawbacks of tantalum and conventional manufacturing techniques. To date, 3D-printed cups have achieved dependable clinical and radiological outcomes with results not inferior to conventional sockets and with good rates of osseointegration. No mechanical failures and no abnormal ion release and biocompatibility warnings have been reported. In this review, we focused on the manufacturing technique, cup features, clinical outcomes, open questions and future developments of off-the-shelf 3D-printed titanium shells in THA.
Collapse
Affiliation(s)
- Francesco Castagnini
- Department of Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna 40136, Italy
| | - Filippo Caternicchia
- Department of Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna 40136, Italy
| | - Federico Biondi
- Department of Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna 40136, Italy
| | - Claudio Masetti
- Department of Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna 40136, Italy
| | - Cesare Faldini
- Department of Clinica I di Ortopedia e Traumatologia, Rizzoli Orthopedic Institute, University of Bologna, Bologna 40136, Italy
- Department of DIBINEM Scienze Biomediche e Neuromotorie, Alma Mater Studiorum Università di Bologna, Bologna 40139, Italy
| | - Francesco Traina
- Department of Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna 40136, Italy
- Department of DIBINEM Scienze Biomediche e Neuromotorie, Alma Mater Studiorum Università di Bologna, Bologna 40139, Italy
| |
Collapse
|
20
|
Osseointegration Improvement of Co-Cr-Mo Alloy Produced by Additive Manufacturing. Pharmaceutics 2021; 13:pharmaceutics13050724. [PMID: 34069254 PMCID: PMC8156199 DOI: 10.3390/pharmaceutics13050724] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 05/07/2021] [Accepted: 05/10/2021] [Indexed: 12/14/2022] Open
Abstract
Cobalt-base alloys (Co-Cr-Mo) are widely employed in dentistry and orthopedic implants due to their biocompatibility, high mechanical strength and wear resistance. The osseointegration of implants can be improved by surface modification techniques. However, complex geometries obtained by additive manufacturing (AM) limits the efficiency of mechanical-based surface modification techniques. Therefore, plasma immersion ion implantation (PIII) is the best alternative, creating nanotopography even in complex structures. In the present study, we report the osseointegration results in three conditions of the additively manufactured Co-Cr-Mo alloy: (i) as-built, (ii) after PIII, and (iii) coated with titanium (Ti) followed by PIII. The metallic samples were designed with a solid half and a porous half to observe the bone ingrowth in different surfaces. Our results revealed that all conditions presented cortical bone formation. The titanium-coated sample exhibited the best biomechanical results, which was attributed to the higher bone ingrowth percentage with almost all medullary canals filled with neoformed bone and the pores of the implant filled and surrounded by bone ingrowth. It was concluded that the metal alloys produced for AM are biocompatible and stimulate bone neoformation, especially when the Co-28Cr-6Mo alloy with a Ti-coated surface, nanostructured and anodized by PIII is used, whose technology has been shown to increase the osseointegration capacity of this implant.
Collapse
|
21
|
Tamayo JA, Riascos M, Vargas CA, Baena LM. Additive manufacturing of Ti6Al4V alloy via electron beam melting for the development of implants for the biomedical industry. Heliyon 2021; 7:e06892. [PMID: 34027149 PMCID: PMC8120950 DOI: 10.1016/j.heliyon.2021.e06892] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 01/27/2021] [Accepted: 04/21/2021] [Indexed: 11/18/2022] Open
Abstract
Additive Manufacturing (AM) or rapid prototyping technologies are presented as one of the best options to produce customized prostheses and implants with high-level requirements in terms of complex geometries, mechanical properties, and short production times. The AM method that has been more investigated to obtain metallic implants for medical and biomedical use is Electron Beam Melting (EBM), which is based on the powder bed fusion technique. One of the most common metals employed to manufacture medical implants is titanium. Although discovered in 1790, titanium and its alloys only started to be used as engineering materials for biomedical prostheses after the 1950s. In the biomedical field, these materials have been mainly employed to facilitate bone adhesion and fixation, as well as for joint replacement surgeries, thanks to their good chemical, mechanical, and biocompatibility properties. Therefore, this study aims to collect relevant and up-to-date information from an exhaustive literature review on EBM and its applications in the medical and biomedical fields. This AM method has become increasingly popular in the manufacturing sector due to its great versatility and geometry control.
Collapse
Affiliation(s)
- José A. Tamayo
- Grupo Calidad, Metrología y Producción, Instituto Tecnológico Metropolitano (ITM), Medellín, Colombia
| | - Mateo Riascos
- Grupo Calidad, Metrología y Producción, Instituto Tecnológico Metropolitano (ITM), Medellín, Colombia
| | - Carlos A. Vargas
- Grupo Materiales Avanzados y Energía (Matyer), Instituto Tecnológico Metropolitano (ITM), Medellín, Colombia
| | - Libia M. Baena
- Grupo de Química Básica, Aplicada y Ambiente (Alquimia), Instituto Tecnológico Metropolitano (ITM), Medellín, Colombia
| |
Collapse
|
22
|
Huang Y, Zhou YX, Tian H, Wang JW, Liu WG, Li H. Minimum 7-year Follow-up of A Porous Coated Trabecular Titanium Cup Manufactured with Electron Beam Melting Technique in Primary Total Hip Arthroplasty. Orthop Surg 2021; 13:817-824. [PMID: 33728818 PMCID: PMC8126901 DOI: 10.1111/os.12846] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 09/04/2020] [Accepted: 09/28/2020] [Indexed: 02/06/2023] Open
Abstract
OBJECTIVES To investigate the cup survivorship, patient satisfaction level, clinical function, and radiographic outcomes of patients who underwent total hip arthroplasty (THA) using electron beam melting (EBM)-produced porous coated titanium cups at mid-term follow up. METHODS A total of 32 patients (32 hips) from five hospitals in China who underwent primary THA using EBM-produced trabecular titanium cups between May and December 2012 were retrospectively reviewed. The inclusion criteria were: (i) patients who underwent THA with the use of EBM-produced cups with possible 7-year follow up; and (ii) patients with follow-up information, including the cup survivorship, patient satisfaction level, and clinical outcomes such as Harris hip score. The exclusion criteria were: (i) patients with neuropathic diseases; and (ii) patients who underwent THA due to neoplastic disease. Five (15.6%) patients were lost to follow up before the 7-year follow-up and, thus, were excluded; none of these patients died due to disease associated with the THA or had undergone removal of their cups as of our last evaluation. The mean age and body mass index of the patients were 59.37 (range: 38.00-69.00) years and 24.51 (range: 16.50-34.10) kg/m2 , respectively. Thirteen (48.1%) of the patients were female. RESULTS The average duration of follow-up was 93.48 (range: 89.00-99.00) months. The median Harris hip score improved from 42.00 (interquartile range: 37.00-49.00) to 97.00 (interquartile range: 92.00-97.00) at the latest follow up (P < 0.001). A total of 18 (66.7%) patients rated their satisfaction level as very satisfied, 6 (22.2%) as satisfied, 2 (7.4%) as neutral and 1 (3.7%) as dissatisfied. No intraoperative or postoperative complications were identified. At the latest follow up, all cups were considered to have achieved osteointegration fixation, with three or more of the five signs evident in the most recent X-ray. However, three cups revealed radiolucent lines with a width of less than 1 mm. The median vertical and horizontal distances between the latest postoperative center of rotation relative to the anatomic center of rotation were 2.50 (interquartile range: -3.10, 6.94) mm superiorly and 3.26 (interquartile range: -8.12, 2.38) mm medially, respectively, at the most recent postoperative follow up. Kaplan-Meier survivorship analysis of cups, with the endpoint defined as postoperative radiolucent lines of less than 1 mm in width in at least two zones, reveals that the 8.25-year survival was 96.3% (95% confidence interval: 76.49%-99.47%). CONCLUSION The mid-term follow-up of patients who underwent primary THA using EBM-produced porous coated titanium cups demonstrated favorable patient satisfaction, good clinical function, excellent survivorship, and adequate biological fixation.
Collapse
Affiliation(s)
- Yong Huang
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Yi-Xin Zhou
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Hua Tian
- Orthopaedic Department, Peking University Third Hospital, Beijing, China
| | - Jun-Wen Wang
- Department of Orthopaedics and Traumatology, Wuhan Fourth Hospital (Puai Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wen-Guang Liu
- Department of Joint Surgery and Sports Medicine, The Second Hospital of Shandong University, Jinan, China
| | - Hu Li
- Department of Orthopaedic Surgery, Peking University People's Hospital, Beijing, China
| |
Collapse
|
23
|
Current interpretations on the in vivo response of bone to additively manufactured metallic porous scaffolds: A review. BIOMATERIALS AND BIOSYSTEMS 2021; 2:100013. [PMID: 36824658 PMCID: PMC9934422 DOI: 10.1016/j.bbiosy.2021.100013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 01/20/2021] [Accepted: 02/13/2021] [Indexed: 01/08/2023] Open
Abstract
Recent advances in the field of metallic additive manufacturing have expanded production capabilities for bone implants to include porous lattice structures. While traditional models of de novo bone formation can be applied to fully dense implant materials, their applicability to the interior of porous materials has not been well-characterized. Unlike other reviews that focus on materials and mechanical properties of lattice structures, this review compiles biological performance from in vivo studies in pre-clinical models only. First, we introduce the most common lattice geometry designs employed in vivo and discuss some of their fabrication advantages and limitations. Then lattice geometry is correlated to quantitative (histomorphometric) and qualitative (histological) assessments of osseointegration. We group studies according to two common implant variables: pore size and percent porosity, and explore the extent of osseointegration using common measures, including bone-implant contact (BIC), bone area (BA), bone volume/total volume (BV/TV) and biomechanical stability, for various animal models and implantation times. Based on this, trends related to in vivo bone formation on the interior of lattice structures are presented. Common challenges with lattice structures are highlighted, including nonuniformity of bone growth through the entirety of the lattice structure due to occlusion effects and avascularity. This review paper identifies a lack of systematic in vivo studies on porous AM implants to target optimum geometric design, including pore shape, size, and percent porosity in controlled animal models and critical-sized defects. Further work focusing on surface modification strategies and systematic geometric studies to homogenize in vivo bone growth through the scaffold interior are recommended to increase implant stability in the early stages of osseointegration.
Collapse
|
24
|
Veronesi F, Torricelli P, Martini L, Tschon M, Giavaresi G, Bellini D, Casagranda V, Alemani F, Fini M. An alternative ex vivo method to evaluate the osseointegration of Ti-6Al-4V alloy also combined with collagen. Biomed Mater 2021; 16:025007. [PMID: 33445161 DOI: 10.1088/1748-605x/abdbda] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Due to the increasing number of orthopedic implantation surgery and advancements in biomaterial manufacturing, chemistry and topography, there is an increasing need of reliable and rapid methods for the preclinical investigation of osseointegration and bone ingrowth. Implant surface composition and topography increase osteogenicity, osteoinductivity, osteoconductivity and osseointegration of a prosthesis. Among the biomaterials used to manufacture an orthopedic prosthesis, titanium alloy (Ti-6Al-4V) is the most used. Type I collagen (COLL I) induces cell function, adhesion, differentiation and bone extracellular matrix component secretion and it is reported to improve osseointegration if immobilized on the alloy surface. The aim of the present study was to evaluate the feasibility of an alternative ex vivo model, developed by culturing rabbit cortical bone segments with Ti-6Al-4V alloy cylinders (Ti-POR), fabricated through the process of electron beam melting (EBM), to evaluate osseointegration. In addition, a comparison was made with Ti-POR coated with COLL I (Ti-POR-COLL) to evaluate osseointegration in terms of bone-to-implant contact (BIC) and new bone formation (nBAr/TAr) at 30, 60 and 90 d of culture. After 30 and 60 d of culture, BIC and nBAr/TAr resulted significantly higher in Ti-POR-COLL implants than in Ti-POR. No differences have been found at 90 d of culture. With the developed model it was possible to distinguish the biomaterial properties and behavior. This study defined and confirmed for the first time the validity of the alternative ex vivo method to evaluate osseointegration and that COLL I improves osseointegration and bone growth of Ti-6Al-4V fabricated through EBM.
Collapse
Affiliation(s)
- Francesca Veronesi
- Complex Structure of Surgical Sciences and Technologies, IRCCS Istituto Ortopedico Rizzoli, Via Di Barbiano 1/10, 40136 Bologna, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Li J, Wang K, Bai X, Wang Q, Lv N, Li Z. Enhanced regeneration of bone defects using sintered porous Ti6Al4V scaffolds incorporated with mesenchymal stem cells and platelet-rich plasma. RSC Adv 2021; 11:5128-5138. [PMID: 35424426 PMCID: PMC8694689 DOI: 10.1039/d0ra10215f] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 01/18/2021] [Indexed: 11/23/2022] Open
Abstract
A new highly controlled powder sintering technique was used for the fabrication of a porous Ti6Al4V scaffold. The platelet-rich plasma (PRP) was prepared using whole blood. The PRP was used as a cell carrier to inject bone marrow mesenchymal stem cells (MSC) into the pores of the Ti6Al4V scaffold in the presence of calcium chloride and thrombin, and then the composite construct of porous Ti6Al4V loaded with PRP gel and MSC was obtained. The bare Ti6Al4V scaffold and the Ti6Al4V scaffold loaded with MSC were used as controls. The characteristics and mechanical properties of the scaffold, and the biological properties of the constructs were evaluated by a series of in vitro and in vivo experiments. The results show that the sintered porous Ti6Al4V has good biocompatibility, and high porosity and large pore size, which can provide sufficient space and sufficient mechanical support for the growth of cells and bones without an obvious stress shielding effect. However, Ti6Al4V/MSC/PRP showed a significantly higher cell proliferation rate, faster bone growth speed, more bone ingrowth, and higher interfacial strength. Therefore, the porous Ti6Al4V scaffolds incorporated with MSC and PRP may be more effective at enhancing bone regeneration, and is expected to be used for bone defect repair.
Collapse
Affiliation(s)
- Ji Li
- Department of Orthopedics, General Hospital of PLA No. 28 Fuxing Road, Haidian District Beijing 100853 China +86 10 66938306 +86 10 66938306
| | - Ketao Wang
- Department of Orthopedics, General Hospital of PLA No. 28 Fuxing Road, Haidian District Beijing 100853 China +86 10 66938306 +86 10 66938306
- Department of Orthopedic Surgery, Zhongshan Hospital, Fudan University Shanghai China
| | - Xiaowei Bai
- Department of Orthopedics, General Hospital of PLA No. 28 Fuxing Road, Haidian District Beijing 100853 China +86 10 66938306 +86 10 66938306
| | - Qi Wang
- Department of Orthopedics, General Hospital of PLA No. 28 Fuxing Road, Haidian District Beijing 100853 China +86 10 66938306 +86 10 66938306
| | - Ningyu Lv
- Department of Orthopedics, General Hospital of PLA No. 28 Fuxing Road, Haidian District Beijing 100853 China +86 10 66938306 +86 10 66938306
| | - Zhongli Li
- Department of Orthopedics, General Hospital of PLA No. 28 Fuxing Road, Haidian District Beijing 100853 China +86 10 66938306 +86 10 66938306
| |
Collapse
|
26
|
Spece H, Basgul C, Andrews CE, MacDonald DW, Taheri ML, Kurtz SM. A systematic review of preclinical in vivo testing of 3D printed porous Ti6Al4V for orthopedic applications, part I: Animal models and bone ingrowth outcome measures. J Biomed Mater Res B Appl Biomater 2021; 109:1436-1454. [PMID: 33484102 DOI: 10.1002/jbm.b.34803] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 11/20/2020] [Accepted: 01/09/2021] [Indexed: 01/20/2023]
Abstract
For Ti6Al4V orthopedic and spinal implants, osseointegration is often achieved using complex porous geometries created via additive manufacturing (AM). While AM porous titanium (pTi) has shown clinical success, concerns regarding metallic implants have spurred interest in alternative AM biomaterials for osseointegration. Insights regarding the evaluation of these new materials may be supported by better understanding the role of preclinical testing for AM pTi. We therefore asked: (a) What animal models have been most commonly used to evaluate AM porous Ti6Al4V for orthopedic bone ingrowth; (b) What were the primary reported quantitative outcome measures for these models; and (c) What were the bone ingrowth outcomes associated with the most frequently used models? We performed a systematic literature search and identified 58 articles meeting our inclusion criteria. We found that AM pTi was evaluated most often using rabbit and sheep femoral condyle defect (FCD) models. Additional ingrowth models including transcortical and segmental defects, spinal fusions, and calvarial defects were also used with various animals based on the study goals. Quantitative outcome measures determined via histomorphometry including ''bone ingrowth'' (range: 3.92-53.4% for rabbit/sheep FCD) and bone-implant contact (range: 9.9-59.7% for rabbit/sheep FCD) were the most common. Studies also used 3D imaging to report outcomes such as bone volume fraction (BV/TV, range: 4.4-61.1% for rabbit/sheep FCD), and push-out testing for outcomes such as maximum removal force (range: 46.6-3092 N for rabbit/sheep FCD). Though there were many commonalities among the study methods, we also found significant heterogeneity in the outcome terms and definitions. The considerable diversity in testing and reporting may no longer be necessary considering the reported success of AM pTi across all model types and the ample literature supporting the rabbit and sheep as suitable small and large animal models, respectively. Ultimately, more standardized animal models and reporting of bone ingrowth for porous AM materials will be useful for future studies.
Collapse
Affiliation(s)
- Hannah Spece
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | - Cemile Basgul
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | | | - Daniel W MacDonald
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | | | - Steven M Kurtz
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.,Exponent, Inc., Philadelphia, Pennsylvania, USA
| |
Collapse
|
27
|
Reproducibility of Replicated Trabecular Bone Structures from Ti6Al4V Extralow Interstitials Powder by Selective Laser Melting. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2021. [DOI: 10.1007/s13369-020-05145-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
28
|
Ahmed A, Al-Rasheed A, Badwelan M, Alghamdi HS. Peri-Implant bone response around porous-surface dental implants: A preclinical meta-analysis. Saudi Dent J 2020; 33:239-247. [PMID: 34194186 PMCID: PMC8236543 DOI: 10.1016/j.sdentj.2020.12.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 12/14/2020] [Accepted: 12/16/2020] [Indexed: 12/09/2022] Open
Abstract
Introduction This meta-analysis of relevant animal studies was conducted to assess whether the use of porous-surface implants improves osseointegration compared to the use of non-porous-surface implants. Material and methods An electronic search of PubMed (MEDLINE) resulted in the selection of ten animal studies (out of 865 publications) for characterization and quality assessment. Risk of bias assessment indicated poor reporting for the majority of studies. The results for bone-implant contact (BIC%) and peri-implant bone formation (BF%) were extracted from the eligible studies and used for the meta-analysis. Data for porous-surface implants were compared to those for non-porous-surface implants, which were considered as the controls. Results The random-effects meta-analysis showed that the use of porous-surface implants did not significantly increase overall BIC% (mean difference or MD: 3.63%; 95% confidence interval or 95% CI: −1.66 to 8.91; p = 0.18), whereas it significantly increased overall BF% (MD: 5.43%; CI: 2.20 to 8.67; p = 0.001), as compared to the controls. Conclusion Porous-surface implants promote osseointegration with increase in BF%. However, their use shows no significant effect on BIC%. Further preclinical and clinical investigations are required to find conclusive evidence on the effect of porous-surface implants.
Collapse
Affiliation(s)
- Abeer Ahmed
- Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Abdulaziz Al-Rasheed
- Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Mohammed Badwelan
- Department of Oral and Maxillofacial Surgery, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.,Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Aden University, Aden, Yemen
| | - Hamdan S Alghamdi
- Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
29
|
Wallace N, Schaffer NE, Aleem IS, Patel R. 3D-printed Patient-specific Spine Implants: A Systematic Review. Clin Spine Surg 2020; 33:400-407. [PMID: 32554986 DOI: 10.1097/bsd.0000000000001026] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
STUDY DESIGN Systematic review. OBJECTIVE To review the current clinical use of 3-dimensional printed (3DP) patient-specific implants in the spine. SUMMARY OF BACKGROUND DATA Additive manufacturing is a transformative manufacturing method now being applied to spinal implants. Recent innovations in technology have allowed the production of medical-grade implants with unprecedented structure and customization, and the complex anatomy of the spine is ideally suited for patient-specific devices. Improvement in implant design through the process of 3DP may lead to improved osseointegration, lower subsidence rates, and faster operative times. METHODS A comprehensive search of the literature was conducted using Ovid MEDLINE, EMBASE, Scopus, and other sources that resulted in 1842 unique articles. All manuscripts describing the use of 3DP spinal implants in humans were included. Two independent reviewers (N.W. and N.E.S.) assessed eligibility for inclusion. The following outcomes were collected: pain score, Japanese Orthopedic Association (JOA) score, subsidence, fusion, Cobb angle, vertebral height, and complications. No conflicts of interest existed. No funding was received for this work. RESULTS A total of 17 studies met inclusion criteria with a total of 35 patients. Only case series and case reports were identified. Follow-up times ranged from 3 to 36 months. Implant types included vertebral body replacement cages, interbody cages, sacral reconstruction prostheses, iliolumbar rods, and a posterior cervical plate. All studies reported improvement in both clinical and radiographic outcomes. 11 of 35 cases showed subsidence >3 mm, but only 1 case required a revision procedure. No migration, loosening, or pseudarthrosis occurred in any patient on the basis of computed tomography or flexion-extension radiographs. CONCLUSIONS Results of the systematic review indicate that 3DP technology is a viable means to fabricate patient-matched spinal implants. The effects on clinical and radiographic outcome measures are still in question, but these devices may produce favorable subsidence and pseudoarthrosis rates. Currently, the technology is ideally suited for complex tumor pathology and atypical bone defects. Future randomized controlled trials and cost analyses are still needed. LEVEL OF EVIDENCE IV-systematic review.
Collapse
Affiliation(s)
- Nicholas Wallace
- Department of Orthopedic Surgery, Division of Spine Surgery, University of Michigan, Ann Arbor, MI
| | | | | | | |
Collapse
|
30
|
Fu J, Xiang Y, Ni M, Qu X, Zhou Y, Hao L, Zhang G, Chen J. In Vivo Reconstruction of the Acetabular Bone Defect by the Individualized Three-Dimensional Printed Porous Augment in a Swine Model. BIOMED RESEARCH INTERNATIONAL 2020; 2020:4542302. [PMID: 33335923 PMCID: PMC7723487 DOI: 10.1155/2020/4542302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 10/14/2020] [Accepted: 11/17/2020] [Indexed: 11/17/2022]
Abstract
METHODS As an acetabular bone defect model created in Bama miniswine, an augment individually fabricated by 3D print technique with Ti6Al4V powders was implanted to repair the defect. Nine swine were divided into three groups, including the immediate biomechanics group, 12-week biomechanics group, and 12-week histological group. The inner structural parameters of the 3D printed porous augment were measured by scanning electron microscopy (SEM), including porosity, pore size, and trabecular diameter. The matching degree between the postoperative augment and the designed augment was assessed by CT scanning and 3D reconstruction. In addition, biomechanical properties, such as stiffness, compressive strength, and the elastic modulus of the 3D printed porous augment, were measured by means of a mechanical testing machine. Moreover, bone ingrowth and implant osseointegration were histomorphometrically assessed. RESULTS In terms of the inner structural parameters of the 3D printed porous augment, the porosity was 55.48 ± 0.61%, pore size 319.23 ± 25.05 μm, and trabecular diameter 240.10 ± 23.50 μm. Biomechanically, the stiffness was 21464.60 ± 1091.69 N/mm, compressive strength 231.10 ± 11.77 MPa, and elastic modulus 5.35 ± 0.23 GPa, respectively. Furthermore, the matching extent between the postoperative augment and the designed one was up to 91.40 ± 2.83%. Besides, the maximal shear strength of the 3D printed augment was 929.46 ± 295.99 N immediately after implantation, whereas the strength was 1521.93 ± 98.38 N 12 weeks after surgery (p = 0.0302). The bone mineral apposition rate (μm per day) 12 weeks post operation was 3.77 ± 0.93 μm/d. The percentage bone volume of new bone was 22.30 ± 4.51% 12 weeks after surgery. CONCLUSION The 3D printed porous Ti6Al4V augment designed in this study was well biocompatible with bone tissue, possessed proper biomechanical features, and was anatomically well matched with the defect bone. Therefore, the 3D printed porous Ti6Al4V augment possesses great potential as an alternative for individualized treatment of severe acetabular bone defects.
Collapse
Affiliation(s)
- Jun Fu
- Department of Orthopaedics, The First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China
| | - Yi Xiang
- Department of Orthopaedics, The Logistics Support Forces of Chinese PLA 985 Hospital, Taiyuan, Shanxi 030001, China
| | - Ming Ni
- Department of Orthopaedics, The First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China
| | - Xiaojuan Qu
- Otolaryngological Department, The Logistics Support Forces of Chinese PLA 985 Hospital, Taiyuan, Shanxi 030001, China
| | - Yonggang Zhou
- Department of Orthopaedics, The First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China
| | - Libo Hao
- Department of Orthopaedics, The First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China
| | - Guoqiang Zhang
- Department of Orthopaedics, The First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China
| | - Jiying Chen
- Department of Orthopaedics, The First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China
| |
Collapse
|
31
|
Martinez-Marquez D, Delmar Y, Sun S, Stewart RA. Exploring Macroporosity of Additively Manufactured Titanium Metamaterials for Bone Regeneration with Quality by Design: A Systematic Literature Review. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E4794. [PMID: 33121025 PMCID: PMC7662257 DOI: 10.3390/ma13214794] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 10/21/2020] [Accepted: 10/23/2020] [Indexed: 12/14/2022]
Abstract
Additive manufacturing facilitates the design of porous metal implants with detailed internal architecture. A rationally designed porous structure can provide to biocompatible titanium alloys biomimetic mechanical and biological properties for bone regeneration. However, increased porosity results in decreased material strength. The porosity and pore sizes that are ideal for porous implants are still controversial in the literature, complicating the justification of a design decision. Recently, metallic porous biomaterials have been proposed for load-bearing applications beyond surface coatings. This recent science lacks standards, but the Quality by Design (QbD) system can assist the design process in a systematic way. This study used the QbD system to explore the Quality Target Product Profile and Ideal Quality Attributes of additively manufactured titanium porous scaffolds for bone regeneration with a biomimetic approach. For this purpose, a total of 807 experimental results extracted from 50 different studies were benchmarked against proposed target values based on bone properties, governmental regulations, and scientific research relevant to bone implants. The scaffold properties such as unit cell geometry, pore size, porosity, compressive strength, and fatigue strength were studied. The results of this study may help future research to effectively direct the design process under the QbD system.
Collapse
Affiliation(s)
| | | | | | - Rodney A. Stewart
- School of Engineering and Built Environment, Griffith University, Gold Coast, QLD 4222, Australia; (D.M.-M.); (Y.D.); (S.S.)
| |
Collapse
|
32
|
Wenhao Z, Zhang T, Yan J, Li Q, Xiong P, Li Y, Cheng Y, Zheng Y. In vitro and in vivo evaluation of structurally-controlled silk fibroin coatings for orthopedic infection and in-situ osteogenesis. Acta Biomater 2020; 116:223-245. [PMID: 32889111 DOI: 10.1016/j.actbio.2020.08.040] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 08/20/2020] [Accepted: 08/26/2020] [Indexed: 01/19/2023]
Abstract
Biomedical device-associated infections (BAI) and osteosynthesis are two main complications following the orthopedic implant surgery, especially while infecting bacteria form a mature biofilm, which can protect the organisms from the host immune system and antibiotic therapy. Comparing with the single antibiotics therapeutic method, the combination of silver nanoparticles (AgNPs) and conventional antibiotics exert a high level of antibacterial activity. Nevertheless, one major issue that extremely restricts the potential application of AgNP/antiviotics is the uncontrolled release. Moreover, the lack of osteogenic ability may cause the osteosynthesis. Thus, herein we fabricated a structure-controlled drug-loaded silk fibroin (SF) coating that can achieve the size and release control of AgNPs and high efficient osteogenesis. Three comparative SF-based coatings were fabricated: α-structured coating (α-helices 32.7%,), m-structured coating (β-sheets 28.3%) and β-structured coating (β-sheets 41%). Owning to the high content of α-helices structure and small AgNPs (20 nm), α-structured coating displayed better protein adsorption and hydrophilicity, as well as pH-dependent and long-lasting antibacterial performance. In vitro studies demonstrated that α coating showed biocompatibility (cellular attachment, spreading and proliferation), high ALP expression, collagen secretion and calcium mineralization. Moreover, after one month subcutaneous implantation in vivo, α-structured coating elicited minimal, comparable inflammatory response. Additionally, in a rabbit femoral defect model, α-structured coating displayed a significant improvement on the generation of new-born bone and bonding between the new bone and the tissue, implying a rapid and durable osteointegration. Expectedly, this optimized structure-controlled SF-based coating can be an alternative and prospective solution for the current challenges in orthopedics. STATEMENT OF SIGNIFICANCE: In this study, an AgNPs/Gentamycin-loaded structured-controlled silk fibroin coatings were constructed on Ti implant's surface to guarantee the success of implantation even in the face of bacterial infection. In comparison, the α-structured coating had the lowest content of β-sheets structure (19.0%) and the smallest particle size of AgNPs (~ 20 nm), and owned pH-responsive characteristic due to reversible α-helices structural. Thanks to pH-responsive release of Ag+, the α-structure coating could effectively inhibit adhesive bacteria and kill planktonic bacteria by releasing a large amount of reactive oxygen radicals. Through in vitro biological results (cell proliferation, differentiation and osteogenic gene expression) and in vivo rabbit femur implantation results, the α-structure coating had good biocompatible and osteogenic properties.
Collapse
Affiliation(s)
- Zhou Wenhao
- Northwest Institute for Nonferrous Metal Research, Xi'an 710016, China; Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China
| | - Teng Zhang
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, China
| | - Jianglong Yan
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China
| | - QiYao Li
- Department of Biomedical Engineering, Materials Research Institute, Huck Institutes of The Life Sciences, The Pennsylvania State University, University Park, PA 16802, United States
| | - Panpan Xiong
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China
| | - Yangyang Li
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China
| | - Yan Cheng
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China.
| | - Yufeng Zheng
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China; Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing 100871, China.
| |
Collapse
|
33
|
Xia Y, Feng ZC, Li C, Wu H, Tang C, Wang L, Li H. Application of additive manufacturing in customized titanium mandibular implants for patients with oral tumors. Oncol Lett 2020; 20:51. [PMID: 32788938 PMCID: PMC7416405 DOI: 10.3892/ol.2020.11912] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2019] [Accepted: 06/18/2020] [Indexed: 01/03/2023] Open
Abstract
The application of additive manufacturing (AM) technology has been widely used in various medical fields, including craniomaxillofacial surgery. The aim of the present study was to examine the surgical efficiency and post-operative outcomes of patient-specific titanium mandibular reconstruction using AM. Major steps in directly designing and manufacturing 3D customized titanium implants are discussed. Furthermore, pre-operative preparations, surgical procedures and post-operative treatment outcomes were compared among patients who received mandibular reconstruction using a customized 3D titanium implant, titanium reconstruction plates or vascularized autologous fibular grafting. Use of a customized titanium implant significantly improved surgical efficiency and precision. When compared with mandibular reconstruction using the two conventional approaches, patients who received the customized implant were significantly more satisfied with their facial appearance, and exhibited minimal post-operative complications in the 12-month follow-up period. Patients who underwent mandibular reconstruction using a customized titanium implant displayed improved mandibular contour symmetry, restored occlusal function, normal range of mouth opening and no temporomandibular joint related pain; all complications frequently experienced by patients who undergo conventional approaches of mandibular reconstruction.
Collapse
Affiliation(s)
- Yan Xia
- Jiangsu Key Laboratory of Oral Disease, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China.,Department of Oral and Maxillofacial Surgery, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Zhi Chao Feng
- Rutgers School of Dental Medicine, Rutgers University, Newark, NJ 07103, USA
| | - Changchun Li
- Department of Stomatology, The Second Hospital of Nanjing, Nanjing, Jiangsu 210003, P.R. China
| | - Heming Wu
- Jiangsu Key Laboratory of Oral Disease, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China.,Department of Oral and Maxillofacial Surgery, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Chunbo Tang
- Jiangsu Key Laboratory of Oral Disease, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Lihua Wang
- AK Medical Holdings Limited, Beijing 100101, P.R China
| | - Hongwei Li
- Jiangsu Key Laboratory of Oral Disease, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China.,Department of Oral and Maxillofacial Surgery, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| |
Collapse
|
34
|
Wang Q, Zhou P, Liu S, Attarilar S, Ma RLW, Zhong Y, Wang L. Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1244. [PMID: 32604854 PMCID: PMC7353126 DOI: 10.3390/nano10061244] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 05/30/2020] [Accepted: 06/22/2020] [Indexed: 02/06/2023]
Abstract
The propose of this review was to summarize the advances in multi-scale surface technology of titanium implants to accelerate the osseointegration process. The several multi-scaled methods used for improving wettability, roughness, and bioactivity of implant surfaces are reviewed. In addition, macro-scale methods (e.g., 3D printing (3DP) and laser surface texturing (LST)), micro-scale (e.g., grit-blasting, acid-etching, and Sand-blasted, Large-grit, and Acid-etching (SLA)) and nano-scale methods (e.g., plasma-spraying and anodization) are also discussed, and these surfaces are known to have favorable properties in clinical applications. Functionalized coatings with organic and non-organic loadings suggest good prospects for the future of modern biotechnology. Nevertheless, because of high cost and low clinical validation, these partial coatings have not been commercially available so far. A large number of in vitro and in vivo investigations are necessary in order to obtain in-depth exploration about the efficiency of functional implant surfaces. The prospective titanium implants should possess the optimum chemistry, bionic characteristics, and standardized modern topographies to achieve rapid osseointegration.
Collapse
Affiliation(s)
- Qingge Wang
- School of Metallurgical Engineering, Xi’an University of Architecture and Technology, No.13 Yanta Road, Xi’an 710055, China;
| | - Peng Zhou
- School of Aeronautical Materials Engineering, Xi’an Aeronautical Polytechnic Institute, Xi’an 710089, China;
| | - Shifeng Liu
- School of Metallurgical Engineering, Xi’an University of Architecture and Technology, No.13 Yanta Road, Xi’an 710055, China;
| | - Shokouh Attarilar
- State Key Laboratory of Metal Matrix Composites, School of Material Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China;
| | - Robin Lok-Wang Ma
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong 999077, China; (R.L.-W.M.); (Y.Z.)
| | - Yinsheng Zhong
- Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong 999077, China; (R.L.-W.M.); (Y.Z.)
| | - Liqiang Wang
- State Key Laboratory of Metal Matrix Composites, School of Material Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China;
- National Engineering Research Center for Nanotechnology (NERCN), 28 East JiangChuan Road, Shanghai 200241, China
| |
Collapse
|
35
|
Memon AR, Wang E, Hu J, Egger J, Chen X. A review on computer-aided design and manufacturing of patient-specific maxillofacial implants. Expert Rev Med Devices 2020; 17:345-356. [PMID: 32105159 PMCID: PMC7175472 DOI: 10.1080/17434440.2020.1736040] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Accepted: 02/25/2020] [Indexed: 10/25/2022]
Abstract
Introduction: Various prefabricated maxillofacial implants are used in the clinical routine for the surgical treatment of patients. In addition to these prefabricated implants, customized CAD/CAM implants become increasingly important for a more precise replacement of damaged anatomical structures. This paper reviews the design and manufacturing of patient-specific implants for the maxillofacial area.Areas covered: The contribution of this publication is to give a state-of-the-art overview in the usage of customized facial implants. Moreover, it provides future perspectives, including 3D printing technologies, for the manufacturing of patient-individual facial implants that are based on patient's data acquisitions, like Computed Tomography (CT) or Magnetic Resonance Imaging (MRI).Expert opinion: The main target of this review is to present various designing software and 3D manufacturing technologies that have been applied to fabricate facial implants. In doing so, different CAD designing software's are discussed, which are based on various methods and have been implemented and evaluated by researchers. Finally, recent 3D printing technologies that have been applied to manufacture patient-individual implants will be introduced and discussed.
Collapse
Affiliation(s)
- Afaque Rafique Memon
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Enpeng Wang
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Junlei Hu
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jan Egger
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute for Computer Graphics and Vision, Faculty of Computer Science and Biomedical Engineering, Graz University of Technology, Graz, Austria
- Department of Oral &maxillofacial Surgery, Medical University of Graz, Graz, Austria
- The Laboratory of Computer Algorithms for Medicine, Medical University of Graz, Graz, Austria
| | - Xiaojun Chen
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
36
|
|
37
|
Zhang T, Wei Q, Fan D, Liu X, Li W, Song C, Tian Y, Cai H, Zheng Y, Liu Z. Improved osseointegration with rhBMP-2 intraoperatively loaded in a specifically designed 3D-printed porous Ti6Al4V vertebral implant. Biomater Sci 2019; 8:1279-1289. [PMID: 31867583 DOI: 10.1039/c9bm01655d] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Three-dimensional (3D)-printed porous Ti6Al4V implants are commonly used for reconstructing bone defects in the treatment of orthopaedic diseases owing to their excellent osteoconduction. However, to achieve improved therapeutic outcomes, the osteoinduction of these implants requires further improvement. The aim of this study was to investigate the combined use of recombinant human BMP-2 (rhBMP-2) with a 3D-printed artificial vertebral implant (3D-AVI) to improve the osteoinduction. Eight male Small Tail Han sheep underwent cervical corpectomy, and 3D-AVIs with or without loaded rhBMP-2 in cavities designed at the center were implanted to treat the cervical defect. Radiographic, micro-computed tomography, fluorescence labelling, and histological examination revealed that the osseointegration efficiency of the rhBMP-2 group was significantly higher than that of the blank control group. The biomechanical test results suggested that rhBMP-2 reduced the range of motion of the cervical spine and provided a more stable implant. Fluorescence observations revealed that the bone tissue grew from the periphery to the center of the 3D-AVIs, first growing into the pore space and then interlocking with the Ti6Al4V implant surface. Therefore, we successfully improved osseointegration of the 3D-AVI by loading rhBMP-2 into the cavity designed at the center of the Ti6Al4V implant, realizing earlier and more stable fixation of implants postoperatively in a simple manner. These benefits of rhBMP-2 are expected to expand the application range and reliability of 3D-printed porous Ti6Al4V implants and improve their therapeutic efficacy.
Collapse
Affiliation(s)
- Teng Zhang
- Department of Orthopedics, Peking University Third Hospital, Beijing 100191, People's Republic of China.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Bandyopadhyay A, Mitra I, Shivaram A, Dasgupta N, Bose S. Direct comparison of additively manufactured porous titanium and tantalum implants towards in vivo osseointegration. ADDITIVE MANUFACTURING 2019; 28:259-266. [PMID: 31406683 PMCID: PMC6690615 DOI: 10.1016/j.addma.2019.04.025] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Material properties of implants such as volume porosity and nanoscale surface modification have been shown to enhance cell-material interactions in vitro and osseointegration in vivo. Porous tantalum (Ta) and titanium (Ti) coatings are widely used for non-cemented implants, which are fabricated using different processing routes. In recent years, some of those implants are being manufactured using additive manufacturing. However, limited knowledge is available on direct comparison of additively manufactured porous Ta and Ti structures towards early stage osseointegration. In this study, we have fabricated porous Ta and Ti6Al4V (Ti64) implants using laser engineered net shaping (LENS™) with similar volume fraction porosity to compare the influence of surface characteristics and material chemistry on in vivo response using a rat distal femur model for 5 and 12 weeks. We have also assessed whether surface modification on Ti64 can elicit similar in vivo response as porous Ta in a rat distal femur model for 5 and 12 weeks. The harvested implants were histologically analyzed for osteoid surface per bone surface. Field emission scanning electron microscopy (FESEM) was done to assess the bone-implant interface. The results presented here indicate comparable performance of porous Ta and surface modified porous Ti64 implants towards early stage osseointegration at 5 weeks post implantation through seamless bone-material interlocking. However, a continued and extended efficacy of porous Ta is found in terms of higher osteoid formation at 12 weeks post-surgery.
Collapse
Affiliation(s)
- Amit Bandyopadhyay
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, 99164, USA
| | - Indranath Mitra
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, 99164, USA
| | - Anish Shivaram
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, 99164, USA
| | - Nairanjana Dasgupta
- Department of Mathematics and Statistics, Washington State University, Pullman, WA, 99164, USA
| | - Susmita Bose
- W. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, 99164, USA
| |
Collapse
|
39
|
Extra low interstitial titanium based fully porous morphological bone scaffolds manufactured using selective laser melting. J Mech Behav Biomed Mater 2019; 95:1-12. [DOI: 10.1016/j.jmbbm.2019.03.025] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 03/12/2019] [Accepted: 03/22/2019] [Indexed: 12/20/2022]
|
40
|
Ni J, Ling H, Zhang S, Wang Z, Peng Z, Benyshek C, Zan R, Miri A, Li Z, Zhang X, Lee J, Lee KJ, Kim HJ, Tebon P, Hoffman T, Dokmeci M, Ashammakhi N, Li X, Khademhosseini A. Three-dimensional printing of metals for biomedical applications. Mater Today Bio 2019; 3:100024. [PMID: 32159151 PMCID: PMC7061633 DOI: 10.1016/j.mtbio.2019.100024] [Citation(s) in RCA: 71] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Revised: 08/08/2019] [Accepted: 08/12/2019] [Indexed: 12/21/2022] Open
Abstract
Three-dimensional (3D) printing technology has received great attention in the past decades in both academia and industry because of its advantages such as customized fabrication, low manufacturing cost, unprecedented capability for complex geometry, and short fabrication period. 3D printing of metals with controllable structures represents a state-of-the-art technology that enables the development of metallic implants for biomedical applications. This review discusses currently existing 3D printing techniques and their applications in developing metallic medical implants and devices. Perspective about the current challenges and future directions for development of this technology is also presented.
Collapse
Affiliation(s)
- J. Ni
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - H. Ling
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Department of Mechanical and Aerospace Engineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - S. Zhang
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - Z. Wang
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - Z. Peng
- Department of Orthopaedic Surgery, Ningbo Medical Treatment Center Lihuili Hospital, PR China
| | - C. Benyshek
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - R. Zan
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - A.K. Miri
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - Z. Li
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| | - X. Zhang
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - J. Lee
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - K.-J. Lee
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - H.-J. Kim
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - P. Tebon
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - T. Hoffman
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - M.R. Dokmeci
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Department of Radiology, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - N. Ashammakhi
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Department of Radiology, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - X. Li
- Department of Mechanical and Aerospace Engineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Department of Materials Science and Engineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
| | - A. Khademhosseini
- Department of Bioengineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Department of Radiology, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Department of Chemical and Biomolecular Engineering, University of California-Los Angeles, Los Angeles, CA 90095, USA
- Department of Bioindustrial Technologies, College of Animal Bioscience and Technology, Konkuk University, Seoul, Republic of Korea
| |
Collapse
|
41
|
Castagnini F, Bordini B, Yorifuji M, Giardina F, Natali S, Pardo F, Traina F. Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty. Med Princ Pract 2019; 28:559-565. [PMID: 31079112 PMCID: PMC6944922 DOI: 10.1159/000500876] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 05/12/2019] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE Highly porous titanium cups have been recently introduced, with contradictory outcomes. A retrospective consecutive case series involving bilateral metachronous total hip arthroplasties (THA) performed with 2 different cups, i.e., Fixa (F) and Fixa Ti-Por (T) (Adler Ortho, Milan, Italy), and the same stem, was evaluated. T sockets, manufactured using electron beam melting, were supposed to prove superior in terms of clinical results, survival rates, and radiographic parameters in comparison to hydroxyapatite-coated F cups with conventional porosity. SUBJECTS AND METHODS Twenty-four bilateral metachronous THAs with an F cup on one side and a T socket on the other side were evaluated. Preoperative and postoperative Harris hip scores (HHS) were collected for every patient. Radiographic signs of loosening were assessed. The radiographic signs of osseointegration (radiolucent lines, superolateral buttress, inferomedial buttress, radial trabeculae, and stress shielding) were evaluated. RESULTS No intraoperative complications occurred. The mean HHS score was excellent and comparable in both groups. At the mean follow-up of 134 months (F) and 79 months (T), no cup or liner revisions were performed. No radiographic signs of loosening were reported. All of the patients revealed 3 parameters of good bony ingrowth at least. Both groups showed similar radiographic parameters regarding osseointegration, which were stable over the time. Stress shielding was more evident in the T cohort (p =0.07). CONCLUSION Highly porous titanium cups produced using an additive manufacturing and electron beam melting technology achieved reliable midterm clinical and radiographic results not inferior to those of second-generation cups.
Collapse
Affiliation(s)
- Francesco Castagnini
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'Anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy,
| | - Barbara Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Makiko Yorifuji
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Federico Giardina
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'Anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Simone Natali
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'Anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Francesco Pardo
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'Anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Francesco Traina
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti d'Anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
42
|
The Size Effect on Forming Quality of Ti–6Al–4V Solid Struts Fabricated via Laser Powder Bed Fusion. METALS 2019. [DOI: 10.3390/met9040416] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Laser powder bed fusion (LPBF) is useful for manufacturing complex structures; however, factors affecting the forming quality have not been clearly researched. This study aimed to clarify the influence of geometric characteristic size on the forming quality of solid struts. Ti–6Al–4V struts with a square section on the side length (0.4 to 1.4 mm) were fabricated with different scan speeds. Micro-computed tomography was used to detect the struts’ profile error and defect distribution. Scanning electron microscopy and light microscopy were used to characterize the samples’ microstructure. Nanoindentation tests were conducted to evaluate the mechanical properties. The experimental results illustrated that geometric characteristic size influenced the struts’ physical characteristics by affecting the cooling condition. This size effect became obvious when the geometric characteristic size and the scan speed were both relatively small. The solid struts with smaller geometric characteristic size had more obvious size error. When the geometric characteristic size was smaller than 1 mm, the nanohardness and elastic modulus increased with the increase in scan speed, and decreased with the decline of the geometric characteristic size. Therefore, a relatively high scan speed should be selected for LPBF—the manufacturing of a porous structure, whose struts have small geometric characteristic size.
Collapse
|
43
|
Elshaer A, Nair S, Hassanin H. Near Net Shape Manufacturing of Dental Implants Using Additive Processes. ACTA ACUST UNITED AC 2019. [DOI: 10.1007/978-3-030-10579-2_4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
|
44
|
Chimutengwende-Gordon M, Dowling R, Pendegrass C, Blunn G. Determining the porous structure for optimal soft-tissue ingrowth: An in vivo histological study. PLoS One 2018; 13:e0206228. [PMID: 30372471 PMCID: PMC6205611 DOI: 10.1371/journal.pone.0206228] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Accepted: 10/09/2018] [Indexed: 11/19/2022] Open
Abstract
The success of osseointegrated transcutaneous prostheses depends on a soft-tissue seal forming at the skin-implant interface in order to prevent infection. Current designs include a flange with drilled holes or a subdermal barrier with a porous coating in an attempt to promote soft-tissue attachment. However, the soft-tissue seal is not reliably achieved despite these designs and infection remains a significant problem. This study investigated soft-tissue integration into fully porous titanium alloy structures with interconnected pores. The study aimed to determine the effect of altering pore and strut size combinations on soft-tissue ingrowth into porous titanium alloy structures in vivo. It was hypothesized that implants with a more open porous structure with larger pore sizes would increase soft-tissue ingrowth more than less open porous structures. Porous titanium alloy cylinders were inserted into sheep paparaspinal muscles (n = 6) and left in situ for four weeks. A histological assessment of soft-tissue ingrowth was performed. Percentage soft-tissue pore fill, cell nuclei density and blood vessel density were quantified. The results showed that larger pore sizes were supportive of soft-tissue ingrowth. A structure with a pore size of 700μm and a strut size of 300μm supported revascularisation to the greatest degree. A flange with this structure may be used in future studies of osseointegrated transcutaneous prostheses in order to enhance the soft-tissue seal.
Collapse
Affiliation(s)
- Mukai Chimutengwende-Gordon
- John Scales Centre for Biomedical Engineering, Institute of Orthopaedics & Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital Trust, Brockley Hill, Stanmore, Middlesex, United Kingdom
- * E-mail:
| | - Robert Dowling
- John Scales Centre for Biomedical Engineering, Institute of Orthopaedics & Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital Trust, Brockley Hill, Stanmore, Middlesex, United Kingdom
| | - Catherine Pendegrass
- John Scales Centre for Biomedical Engineering, Institute of Orthopaedics & Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital Trust, Brockley Hill, Stanmore, Middlesex, United Kingdom
| | - Gordon Blunn
- John Scales Centre for Biomedical Engineering, Institute of Orthopaedics & Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital Trust, Brockley Hill, Stanmore, Middlesex, United Kingdom
| |
Collapse
|
45
|
Ortiz-Hernandez M, Rappe KS, Molmeneu M, Mas-Moruno C, Guillem-Marti J, Punset M, Caparros C, Calero J, Franch J, Fernandez-Fairen M, Gil J. Two Different Strategies to Enhance Osseointegration in Porous Titanium: Inorganic Thermo-Chemical Treatment Versus Organic Coating by Peptide Adsorption. Int J Mol Sci 2018; 19:ijms19092574. [PMID: 30200178 PMCID: PMC6163352 DOI: 10.3390/ijms19092574] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2018] [Revised: 08/08/2018] [Accepted: 08/25/2018] [Indexed: 01/24/2023] Open
Abstract
In this study, highly-interconnected porous titanium implants were produced by powder sintering with different porous diameters and open interconnectivity. The actual foams were produced using high cost technologies: Chemical Vapor Deposition (CVD), Physical Vapor Deposition (PVD), and spark plasma sintering, and the porosity and/or interconnection was not optimized. The aim was to generate a bioactive surface on foams using two different strategies, based on inorganic thermo-chemical treatment and organic coating by peptide adsorption, to enhance osseointegration. Porosity was produced using NaCl as a space holder and polyethyleneglicol as a binder phase. Static and fatigue tests were performed in order to determine mechanical behaviors. Surface bioactivation was performed using a thermo-chemical treatment or by chemical adsorption with peptides. Osteoblast-like cells were cultured and cytotoxicity was measured. Bioactivated scaffolds and a control were implanted in the tibiae of rabbits. Histomorphometric evaluation was performed at 4 weeks after implantation. Interconnected porosity was 53% with an average diameter of 210 µm and an elastic modulus of around 1 GPa with good mechanical properties. The samples presented cell survival values close to 100% of viability. Newly formed bone was observed inside macropores, through interconnected porosity, and on the implant surface. Successful bone colonization of inner structure (40%) suggested good osteoconductive capability of the implant. Bioactivated foams showed better results than non-treated ones, suggesting both bioactivation strategies induce osteointegration capability.
Collapse
Affiliation(s)
- Monica Ortiz-Hernandez
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Metallurgical Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
| | - Katrin S Rappe
- Departamento de Cirugía Animal, Facultad de Veterinaria, Universidad Autónoma de Barcelona, Bellaterra, 08193 Barcelona, Spain.
| | - Meritxell Molmeneu
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Metallurgical Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
| | - Carles Mas-Moruno
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Metallurgical Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
| | - Jordi Guillem-Marti
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Metallurgical Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
| | - Miquel Punset
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Metallurgical Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
| | - Cristina Caparros
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Metallurgical Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
| | - Jose Calero
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Metallurgical Engineering, Universitat Politècnica de Catalunya (UPC), 08019 Barcelona, Spain.
| | - Jordi Franch
- Departamento de Cirugía Animal, Facultad de Veterinaria, Universidad Autónoma de Barcelona, Bellaterra, 08193 Barcelona, Spain.
| | - Mariano Fernandez-Fairen
- Facultad de Odontología, Campus de Medicina y Ciencias de la Salud, Universidad Internacional de Cataluña (UIC), 08017 Barcelona, Spain.
| | - Javier Gil
- Facultad de Odontología, Campus de Medicina y Ciencias de la Salud, Universidad Internacional de Cataluña (UIC), 08017 Barcelona, Spain.
| |
Collapse
|
46
|
Wang F, Wang L, Feng Y, Yang X, Ma Z, Shi L, Ma X, Wang J, Ma T, Yang Z, Wen X, Zhang Y, Lei W. Evaluation of an artificial vertebral body fabricated by a tantalum-coated porous titanium scaffold for lumbar vertebral defect repair in rabbits. Sci Rep 2018; 8:8927. [PMID: 29895937 PMCID: PMC5997693 DOI: 10.1038/s41598-018-27182-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Accepted: 05/25/2018] [Indexed: 11/09/2022] Open
Abstract
Tantalum (Ta)-coated porous Ti-6A1-4V scaffolds have better bioactivity than Ti-6A1-4V scaffolds; however, their bioperformance as an artificial vertebral body (AVB) is unknown. In the present study, we combined a Ta-coated Ti-6A1-4V scaffold with rabbit bone marrow stromal cells (BMSCs) for tissue-engineered AVB (TEAVB) construction and evaluated the healing and fusion efficacy of this scaffold in lumbar vertebral defects after corpectomy in rabbits. The results showed that BMSCs on the surface of the Ta-coated Ti scaffolds proliferated better than BMSCs on Ti scaffolds. Histomorphometry showed better bone formation when using Ta-coated TEAVBs than that with Ti TEAVBs at both 8 and 12 weeks after implantation. In addition, the vertical and rotational stiffness results showed that, compared with uncoated TEAVBs, Ta-coated TEAVBs enhanced rabbit lumbar vertebral defect repair. Our findings demonstrate that Ta-coated TEAVBs have better healing and fusion efficacy than Ti TEAVBs in rabbit lumbar vertebral defects, which indicates their good prospects for clinical application.
Collapse
Affiliation(s)
- Faqi Wang
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Lin Wang
- Department of orthopedic surgery, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Yafei Feng
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Xiaojiang Yang
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Zhensheng Ma
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Lei Shi
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Xiangyu Ma
- The 463 hospital of Chinese Peoples' Liberation Army, Shenyang, China
| | - Jian Wang
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | | | - Zhao Yang
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China
| | - Xinxin Wen
- The 463 hospital of Chinese Peoples' Liberation Army, Shenyang, China
| | - Yang Zhang
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China.
| | - Wei Lei
- Institute of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi'an, China.
| |
Collapse
|
47
|
Weißmann V, Drescher P, Seitz H, Hansmann H, Bader R, Seyfarth A, Klinder A, Jonitz-Heincke A. Effects of Build Orientation on Surface Morphology and Bone Cell Activity of Additively Manufactured Ti6Al4V Specimens. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E915. [PMID: 29844256 PMCID: PMC6024895 DOI: 10.3390/ma11060915] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 05/22/2018] [Accepted: 05/25/2018] [Indexed: 12/30/2022]
Abstract
Additive manufacturing of lightweight or functional structures by selective laser beam (SLM) or electron beam melting (EBM) is widespread, especially in the field of medical applications. SLM and EBM processes were applied to prepare Ti6Al4V test specimens with different surface orientations (0°, 45° and 90°). Roughness measurements of the surfaces were conducted and cell behavior on these surfaces was analyzed. Hence, human osteoblasts were seeded on test specimens to determine cell viability (metabolic activity, live-dead staining) and gene expression of collagen type 1 (Col1A1), matrix metalloprotease (MMP) 1 and its natural inhibitor, TIMP1, after 3 and 7 days. The surface orientation of specimens during the manufacturing process significantly influenced the roughness. Surface roughness showed significant impact on cellular viability, whereas differences between the time points day 3 and 7 were not found. Collagen type 1 mRNA synthesis rates in human osteoblasts were enhanced with increasing roughness. Both manufacturing techniques further influenced the induction of bone formation process in the cell culture. Moreover, the relationship between osteoblastic collagen type 1 mRNA synthesis rates and specimen orientation during the building process could be characterized by functional formulas. These findings are useful in the designing of biomedical applications and medical devices.
Collapse
Affiliation(s)
- Volker Weißmann
- Faculty of Engineering, University of Applied Science, Technology, Business and Design, Philipp-Müller-Str. 14, 23966 Wismar, Germany.
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Centre, Doberaner Strasse 142, Rostock 18057, Germany.
| | - Philipp Drescher
- Fluid Technology and Microfluidics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, 18059 Rostock, Germany.
| | - Hermann Seitz
- Fluid Technology and Microfluidics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, 18059 Rostock, Germany.
| | - Harald Hansmann
- Institute for Polymer Technologies e.V., Alter Holzhafen 19, 23966 Wismar, Germany.
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Centre, Doberaner Strasse 142, Rostock 18057, Germany.
| | - Anika Seyfarth
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Centre, Doberaner Strasse 142, Rostock 18057, Germany.
| | - Annett Klinder
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Centre, Doberaner Strasse 142, Rostock 18057, Germany.
| | - Anika Jonitz-Heincke
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Centre, Doberaner Strasse 142, Rostock 18057, Germany.
| |
Collapse
|
48
|
Harun W, Manam N, Kamariah M, Sharif S, Zulkifly A, Ahmad I, Miura H. A review of powdered additive manufacturing techniques for Ti-6al-4v biomedical applications. POWDER TECHNOL 2018. [DOI: 10.1016/j.powtec.2018.03.010] [Citation(s) in RCA: 80] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
49
|
Geometric Modeling of Cellular Materials for Additive Manufacturing in Biomedical Field: A Review. Appl Bionics Biomech 2018; 2018:1654782. [PMID: 29487626 PMCID: PMC5816891 DOI: 10.1155/2018/1654782] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Accepted: 10/26/2017] [Indexed: 02/07/2023] Open
Abstract
Advances in additive manufacturing technologies facilitate the fabrication of cellular materials that have tailored functional characteristics. The application of solid freeform fabrication techniques is especially exploited in designing scaffolds for tissue engineering. In this review, firstly, a classification of cellular materials from a geometric point of view is proposed; then, the main approaches on geometric modeling of cellular materials are discussed. Finally, an investigation on porous scaffolds fabricated by additive manufacturing technologies is pointed out. Perspectives in geometric modeling of scaffolds for tissue engineering are also proposed.
Collapse
|
50
|
Additive manufacturing of titanium alloys in the biomedical field: processes, properties and applications. J Appl Biomater Funct Mater 2017; 16:57-67. [DOI: 10.5301/jabfm.5000371] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
The mechanical properties and biocompatibility of titanium alloy medical devices and implants produced by additive manufacturing (AM) technologies – in particular, selective laser melting (SLM), electron beam melting (EBM) and laser metal deposition (LMD) – have been investigated by several researchers demonstrating how these innovative processes are able to fulfil medical requirements for clinical applications. This work reviews the advantages given by these technologies, which include the possibility to create porous complex structures to improve osseointegration and mechanical properties (best match with the modulus of elasticity of local bone), to lower processing costs, to produce custom-made implants according to the data for the patient acquired via computed tomography and to reduce waste.
Collapse
|