1
|
Pawelec KM, Schoborg TA, Shapiro EM. Computed tomography technologies to measure key structural features of polymeric biomedical implants from bench to bedside. J Biomed Mater Res A 2024; 112:1893-1901. [PMID: 38728118 PMCID: PMC11368623 DOI: 10.1002/jbm.a.37735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 04/11/2024] [Accepted: 04/30/2024] [Indexed: 05/12/2024]
Abstract
Implanted polymeric devices, designed to encourage tissue regeneration, require porosity. However, characterizing porosity, which affects many functional device properties, is non-trivial. Computed tomography (CT) is a quick, versatile, and non-destructive way to gain 3D structural information, yet various CT technologies, such as benchtop, preclinical and clinical systems, all have different capabilities. As system capabilities determine the structural information that can be obtained, seamless monitoring of key device features through all stages of clinical translation must be engineered intentionally. Therefore, in this study we tested feasibility of obtaining structural information in pre-clinical systems and high-resolution micro-CT (μCT) under physiological conditions. To overcome the low CT contrast of polymers in hydrated environments, radiopaque nanoparticle contrast agent was incorporated into porous devices. The size of resolved features in porous structures is highly dependent on the resolution (voxel size) of the scan. As the voxel size of the CT scan increased (lower resolution) from 5 to 50 μm, the measured pore size was overestimated, and percentage porosity was underestimated by nearly 50%. With the homogeneous introduction of nanoparticles, changes to device structure could be quantified in the hydrated state, including at high-resolution. Biopolymers had significant structural changes post-hydration, including a mean increase of 130% in pore wall thickness that could potentially impact biological response. By incorporating imaging capabilities into polymeric devices, CT can be a facile way to monitor devices from initial design stages through to clinical translation.
Collapse
Affiliation(s)
- Kendell M Pawelec
- Michigan State University, Dept Radiology, East Lansing, MI 48824
- Institute for Quantitative Health Sciences and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Todd A Schoborg
- University of Wyoming, Dept of Molecular Biology, Laramie, WY 82071
| | - Erik M Shapiro
- Michigan State University, Dept Radiology, East Lansing, MI 48824
- Institute for Quantitative Health Sciences and Engineering, Michigan State University, East Lansing, MI 48824, USA
- Michigan State University, Dept of Physiology, East Lansing, MI 48824, USA
- Michigan State University, Dept of Chemical Engineering and Material Science, East Lansing, MI 48824, USA
- Michigan State University, Dept of Biomedical Engineering, East Lansing, MI 48824, USA
| |
Collapse
|
2
|
Khan PA, Raheem A, Kalirajan C, Prashanth KG, Manivasagam G. In Vivo Assessment of a Triple Periodic Minimal Surface Based Biomimmetic Gyroid as an Implant Material in a Rabbit Tibia Model. ACS MATERIALS AU 2024; 4:479-488. [PMID: 39280806 PMCID: PMC11393938 DOI: 10.1021/acsmaterialsau.4c00016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 05/19/2024] [Accepted: 05/22/2024] [Indexed: 09/18/2024]
Abstract
Biomimetic approaches to implant construction are a rising frontier in implantology. Triple Periodic Minimal Surface (TPMS)-based additively manufactured gyroid structures offer a mean curvature of zero, rendering this structure an ideal porous architecture. Previous studies have demonstrated the ability of these structures to effectively mimic the mechanical cues required for optimal implant construction. The porous nature of gyroid materials enhances bone ingrowth, thereby improving implant stability within the body. This enhancement is attributed to the increased surface area of the gyroid structure, which is approximately 185% higher than that of a dense material of the same form factor. This larger surface area allows for enhanced cellular attachment and nutrient circulation facilitated by the porous channels. This study aims to evaluate the biological performance of a gyroid-based Ti6Al-4V implant material compared to a dense alloy counterpart. Cellular viability was assessed using the lactate dehydrogenase (LDH) assay, which demonstrated that the gyroid surface allowed marginally higher viability than dense material. The in vivo integration was studied over 6 weeks using a rabbit tibia model and characterized using X-ray, micro-CT, and histopathological examination. With a metal volume of 8.1%, the gyroid exhibited a bone volume/total volume (BV/TV) ratio of 9.6%, which is 11-fold higher than that of dense metal (0.8%). Histological assessments revealed neovascularization, in-bone growth, and the presence of a Haversian system in the gyroid structure, hinting at superior osteointegration.
Collapse
Affiliation(s)
- Pearlin Amaan Khan
- Centre for Biomaterials, Cellular, and Molecular Theranostics, Vellore Institute of Technology, Vellore 632014, India
| | - Ansheed Raheem
- Centre for Biomaterials, Cellular, and Molecular Theranostics, Vellore Institute of Technology, Vellore 632014, India
| | - Cheirmadurai Kalirajan
- Centre for Biomaterials, Cellular, and Molecular Theranostics, Vellore Institute of Technology, Vellore 632014, India
| | - Konda Gokuldoss Prashanth
- Centre for Biomaterials, Cellular, and Molecular Theranostics, Vellore Institute of Technology, Vellore 632014, India
- Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia
| | - Geetha Manivasagam
- Centre for Biomaterials, Cellular, and Molecular Theranostics, Vellore Institute of Technology, Vellore 632014, India
| |
Collapse
|
3
|
Vom Scheidt A, Krug J, Goggin P, Bakker AD, Busse B. 2D vs. 3D Evaluation of Osteocyte Lacunae - Methodological Approaches, Recommended Parameters, and Challenges: A Narrative Review by the European Calcified Tissue Society (ECTS). Curr Osteoporos Rep 2024; 22:396-415. [PMID: 38980532 PMCID: PMC11324773 DOI: 10.1007/s11914-024-00877-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/11/2024] [Indexed: 07/10/2024]
Abstract
PURPOSE OF REVIEW Quantification of the morphology of osteocyte lacunae has become a powerful tool to investigate bone metabolism, pathologies and aging. This review will provide a brief overview of 2D and 3D imaging methods for the determination of lacunar shape, orientation, density, and volume. Deviations between 2D-based and 3D-based lacunar volume estimations are often not sufficiently addressed and may give rise to contradictory findings. Thus, the systematic error arising from 2D-based estimations of lacunar volume will be discussed, and an alternative calculation proposed. Further, standardized morphological parameters and best practices for sampling and segmentation are suggested. RECENT FINDINGS We quantified the errors in reported estimation methods of lacunar volume based on 2D cross-sections, which increase with variations in lacunar orientation and histological cutting plane. The estimations of lacunar volume based on common practice in 2D imaging methods resulted in an underestimation of lacunar volume of up to 85% compared to actual lacunar volume in an artificial dataset. For a representative estimation of lacunar size and morphology based on 2D images, at least 400 lacunae should be assessed per sample.
Collapse
Affiliation(s)
- Annika Vom Scheidt
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Auenbruggerplatz 25, Graz, 8036, Austria.
| | - Johannes Krug
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany
- Interdisciplinary Competence Center for Interface Research, University Medical Center Hamburg-Eppendorf, Butenfeld 34, 22529, Hamburg, Germany
| | - Patricia Goggin
- Biomedical Imaging Unit, Laboratory and Pathology Block, University of Southampton, Southampton General Hospital, Tremona Road, Southampton, SO16 6YD, UK
| | - Astrid Diana Bakker
- Department of Oral Cell Biology, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam Movement Sciences, University of Amsterdam and Vrije Universiteit Amsterdam, Gustav Mahlerlaan, Amsterdam, 3004, 1081 LA, The Netherlands
| | - Björn Busse
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany
- Interdisciplinary Competence Center for Interface Research, University Medical Center Hamburg-Eppendorf, Butenfeld 34, 22529, Hamburg, Germany
| |
Collapse
|
4
|
Evrard R, Manon J, Rafferty C, Fieve L, Cornu O, Kirchgesner T, Lecouvet FE, Schubert T, Lengele B. Vascular study of decellularized porcine long bones: Characterization of a tissue engineering model. Bone 2024; 182:117073. [PMID: 38493932 DOI: 10.1016/j.bone.2024.117073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 03/12/2024] [Accepted: 03/14/2024] [Indexed: 03/19/2024]
Abstract
INTRODUCTION Massive bone allografts enable the reconstruction of critical bone defects in numerous conditions (e.g. tumoral, infection or trauma). Unfortunately, their biological integration remains insufficient and the reconstruction may suffer from several postoperative complications. Perfusion-decellularization emerges as a tissue engineering potential solution to enhance osseointegration. Therefore, an intrinsic vascular study of this novel tissue engineering tool becomes essential to understand its efficacy and applicability. MATERIAL AND METHODS 32 porcine long bones (humeri and femurs) were used to assess the quality of their vascular network prior and after undergoing a perfusion-decellularization protocol. 12 paired bones were used to assess the vascular matrix prior (N = 6) and after our protocol (N = 6) by immunohistochemistry. Collagen IV, Von Willebrand factor and CD31 were targeted then quantified. The medullary macroscopic vascular network was evaluated with 12 bones: 6 were decellularized and the other 6 were, as control, not treated. All 12 underwent a contrast-agent injection through the nutrient artery prior an angio CT-scan acquisition. The images were processed and the length of medullary vessels filled with contrast agent were measured on angiographic cT images obtained in control and decellularized bones by 4 independent observers to evaluate the vascular network preservation. The microscopic cortical vascular network was evaluated on 8 bones: 4 control and 4 decellularized. After injection of gelatinous fluorochrome mixture (calcein green), non-decalcified fluoroscopic microscopy was performed in order to assess the perfusion quality of cortical vascular lacunae. RESULTS The continuity of the microscopic vascular network was assessed with Collagen IV immunohistochemistry (p-value = 0.805) while the decellularization quality was observed through CD31 and Von Willebrand factor immunohistochemistry (p-values <0.001). The macroscopic vascular network was severely impaired after perfusion-decellularization; nutrient arteries were still patent but the amount of medullary vascular channels measured was significantly higher in the control group compared to the decellularized group (p-value <0.001). On average, the observers show good agreement on these results, except in the decellularized group where more inter-observer discrepancies were observed. The microscopic vascular network was observed with green fluoroscopic signal in almost every canals and lacunae of the bone cortices, in three different bone locations (proximal metaphysis, diaphysis and distal metaphysis). CONCLUSION Despite the aggressiveness of the decellularization protocol on medullary vessels, total porcine long bones decellularized by perfusion retain an acellular cortical microvascular network. By injection through the intact nutrient arteries, this latter vascular network can still be used as a total bone infusion access for bone tissue engineering in order to enhance massive bone allografts prior implantation.
Collapse
Affiliation(s)
- R Evrard
- Institut de Recherche Expérimentale et Clinique, Neuro Musculo-Skeletal Lab, Université Catholique de Louvain (UCLouvain), Avenue E. Mounier, 52-B1.52.04, 1200 Bruxelles, Belgium; Service de Chirurgie Orthopédique et Traumatologique, Cliniques Universitaires Saint-Luc, UCLouvain, Avenue Hippocrate 10, 1200 Bruxelles, Belgium.
| | - J Manon
- Institut de Recherche Expérimentale et Clinique, Neuro Musculo-Skeletal Lab, Université Catholique de Louvain (UCLouvain), Avenue E. Mounier, 52-B1.52.04, 1200 Bruxelles, Belgium; Service de Chirurgie Orthopédique et Traumatologique, Cliniques Universitaires Saint-Luc, UCLouvain, Avenue Hippocrate 10, 1200 Bruxelles, Belgium
| | - C Rafferty
- Institut de Recherche Expérimentale et Clinique, Pôle Morphologie, UCLouvain, Avenue E. Mounier, 52-B1.52.04, 1200 Bruxelles, Belgium
| | - L Fieve
- Institut de Recherche Expérimentale et Clinique, Pôle Morphologie, UCLouvain, Avenue E. Mounier, 52-B1.52.04, 1200 Bruxelles, Belgium
| | - O Cornu
- Institut de Recherche Expérimentale et Clinique, Neuro Musculo-Skeletal Lab, Université Catholique de Louvain (UCLouvain), Avenue E. Mounier, 52-B1.52.04, 1200 Bruxelles, Belgium; Service de Chirurgie Orthopédique et Traumatologique, Cliniques Universitaires Saint-Luc, UCLouvain, Avenue Hippocrate 10, 1200 Bruxelles, Belgium; Unité de Thérapie Tissulaire et Cellulaire de l'Appareil Locomoteur, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Bruxelles, Belgium
| | - T Kirchgesner
- Département d'Imagerie Médicale, Institut de Recherche Expérimentale et Clinique (Pôle IMAG), Cliniques Universitaires Saint-Luc, UCLouvain, Avenue Hippocrate 10, 1200 Bruxelles, Belgium
| | - F E Lecouvet
- Département d'Imagerie Médicale, Institut de Recherche Expérimentale et Clinique (Pôle IMAG), Cliniques Universitaires Saint-Luc, UCLouvain, Avenue Hippocrate 10, 1200 Bruxelles, Belgium
| | - T Schubert
- Institut de Recherche Expérimentale et Clinique, Neuro Musculo-Skeletal Lab, Université Catholique de Louvain (UCLouvain), Avenue E. Mounier, 52-B1.52.04, 1200 Bruxelles, Belgium; Service de Chirurgie Orthopédique et Traumatologique, Cliniques Universitaires Saint-Luc, UCLouvain, Avenue Hippocrate 10, 1200 Bruxelles, Belgium; Unité de Thérapie Tissulaire et Cellulaire de l'Appareil Locomoteur, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Bruxelles, Belgium
| | - B Lengele
- Institut de Recherche Expérimentale et Clinique, Pôle Morphologie, UCLouvain, Avenue E. Mounier, 52-B1.52.04, 1200 Bruxelles, Belgium; Service de Chirurgie Plastique, Reconstructrice et Esthétique, Cliniques Universitaires Saint-Luc, UCLouvain, Avenue Hippocrate 10, 1200 Bruxelles, Belgium
| |
Collapse
|
5
|
Silveira A, Greving I, Longo E, Scheel M, Weitkamp T, Fleck C, Shahar R, Zaslansky P. Deep learning to overcome Zernike phase-contrast nanoCT artifacts for automated micro-nano porosity segmentation in bone. JOURNAL OF SYNCHROTRON RADIATION 2024; 31:136-149. [PMID: 38095668 PMCID: PMC10833422 DOI: 10.1107/s1600577523009852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 11/13/2023] [Indexed: 01/09/2024]
Abstract
Bone material contains a hierarchical network of micro- and nano-cavities and channels, known as the lacuna-canalicular network (LCN), that is thought to play an important role in mechanobiology and turnover. The LCN comprises micrometer-sized lacunae, voids that house osteocytes, and submicrometer-sized canaliculi that connect bone cells. Characterization of this network in three dimensions is crucial for many bone studies. To quantify X-ray Zernike phase-contrast nanotomography data, deep learning is used to isolate and assess porosity in artifact-laden tomographies of zebrafish bones. A technical solution is proposed to overcome the halo and shade-off domains in order to reliably obtain the distribution and morphology of the LCN in the tomographic data. Convolutional neural network (CNN) models are utilized with increasing numbers of images, repeatedly validated by `error loss' and `accuracy' metrics. U-Net and Sensor3D CNN models were trained on data obtained from two different synchrotron Zernike phase-contrast transmission X-ray microscopes, the ANATOMIX beamline at SOLEIL (Paris, France) and the P05 beamline at PETRA III (Hamburg, Germany). The Sensor3D CNN model with a smaller batch size of 32 and a training data size of 70 images showed the best performance (accuracy 0.983 and error loss 0.032). The analysis procedures, validated by comparison with human-identified ground-truth images, correctly identified the voids within the bone matrix. This proposed approach may have further application to classify structures in volumetric images that contain non-linear artifacts that degrade image quality and hinder feature identification.
Collapse
Affiliation(s)
- Andreia Silveira
- Department for Restorative, Preventive and Pediatric Dentistry, Charité-Universitaetsmedizin, Berlin, Germany
| | - Imke Greving
- Institute of Materials Physics, Helmholtz-Zentrum Hereon, Geesthacht, Germany
| | - Elena Longo
- Elettra – Sincrotrone Trieste SCpA, Basovizza, Trieste, Italy
| | | | | | - Claudia Fleck
- Fachgebiet Werkstofftechnik / Chair of Materials Science and Engineering, Institute of Materials Science and Technology, Faculty III Process Sciences, Technische Universität Berlin, Berlin, Germany
| | - Ron Shahar
- Koret School of Veterinary Medicine, The Robert H. Smith Faculty of Agriculture, Food and Environmental Sciences, Hebrew University of Jerusalem, Rehovot, Israel
| | - Paul Zaslansky
- Department for Restorative, Preventive and Pediatric Dentistry, Charité-Universitaetsmedizin, Berlin, Germany
| |
Collapse
|
6
|
Kurtz T, Woitrain T, Godio-Raboutet Y, Ribeiro FLB, Arnoux PJ, Tailhan JL. Method for Evaluating Cortical Bone Young's Modulus: Numerical Twin Reconstruction, Finite Element Calculation, and Microstructure Analysis. J Biomech Eng 2023; 145:111013. [PMID: 37542711 DOI: 10.1115/1.4063100] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 07/17/2023] [Indexed: 08/07/2023]
Abstract
The determination of bone mechanical properties remains crucial, especially to feed up numerical models. An original methodology of inverse analysis has been developed to determine the longitudinal elastic modulus of femoral cortical bone. The method is based on a numerical twin of a specific three-point bending test. It has been designed to be reproducible on each test result. In addition, the biofidelity of the geometric acquisition method has been quantified. As the assessment is performed at the scale of a bone shaft segment, the Young's modulus values obtained (between 9518.29 MPa and 14181.15 MPa) are considered average values for the whole tissue, highlighting some intersubject variability. The material microstructure has also been studied through histological analysis, and bone-to-bone comparisons highlighted discrepancies in quadrants microstructures. Furthermore, significant intrasubject variability exists since differences between the bone's medial-lateral and anterior-posterior quadrants have been observed. Thus, the study of microstructures can largely explain the differences between the elastic modulus values obtained. However, a more in-depth study of bone mineral density would also be necessary and would provide some additional information. This study is currently being setup, alongside an investigation of the local variations of the elastic modulus.
Collapse
Affiliation(s)
- T Kurtz
- Aix Marseille Univ, Univ Gustave Eiffel, LBA, Marseille 13015, France
| | - T Woitrain
- Aix Marseille Univ, Univ Gustave Eiffel, LBA, Marseille 13015, France
| | - Y Godio-Raboutet
- Aix Marseille Univ, Univ Gustave Eiffel, LBA, Marseille 13015, France
| | - F L B Ribeiro
- Department of Civil Engineering, COPPE, Federal University of Rio de Janeiro, Centro de Tecnologia - Ilha do Fundao, Rio de Janeiro 21941, Brazil
| | - P-J Arnoux
- Aix Marseille Univ, Univ Gustave Eiffel, LBA, Marseille 13015, France
| | - J-L Tailhan
- Univ Gustave Eiffel, MAST-EMGCU, Marne la Vallée 77454, France
| |
Collapse
|
7
|
Irie MS, Spin-Neto R, Teixeira LHS, Rabelo GD, Reis NTDA, Soares PBF. Effect of micro-CT acquisition parameters and individual analysis on the assessment of bone repair. Braz Oral Res 2023; 37:e099. [PMID: 38055517 DOI: 10.1590/1807-3107bor-2023.vol37.0099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 08/23/2022] [Indexed: 12/08/2023] Open
Abstract
This study aimed to investigate whether two acquisition parameters, voxel size and filter thickness, used in a micro-computed tomography (micro-CT) scan, together with the examiner's experience, influence the outcome of bone repair analysis in an experimental model. Bone defects were created in rat tibiae and scanned using two voxel sizes of 6- or 12-µm and two aluminum filter thickness of 0.5- or 1-mm. Then, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th) were analyzed twice by two groups of operators: experienced and inexperienced examiners. For BV/TV, no significant differences were found between scanning voxel sizes of 6 and 12 µm for the experienced examiners; however, for the inexperienced examiners, the analysis performed using a 12-µm voxel size resulted in higher BV/TV values (32.4 and 32.9) than those acquired using a 6-µm voxel size (25.4 and 24.8) (p < 0.05). For Tb.Th, no significant differences between the analyses performed by experienced and inexperienced groups were observed when using the 6-µm voxel size. However, inexperienced examiners' analysis revealed higher Tb.Th values when using the 12-µm voxel size compared with 6 µm (0.05 vs. 0.03, p < 0.05). Filter thickness had no influence on the results of any group. In conclusion, voxel size and operator experience affected the measured Tb.Th and BV/TV of a region with new bone formation. Operator experience in micro-CT analysis is more critical for BV/TV than for Tb.Th, whereas voxel size significantly affects Tb.Th evaluation. Operators in the initial phases of research training should be calibrated for bone assessments.
Collapse
Affiliation(s)
- Milena Suemi Irie
- Universidade Federal de Uberlândia - UFU, School of Dentistry, Department of Periodontology and Implantology, Uberlândia, MG, Brazil
| | - Rubens Spin-Neto
- Aarhus University, Department of Dentistry and Oral Health, Health, Aarhus, Denmark
| | - Lucas Henrique Souza Teixeira
- Universidade Federal de Uberlândia - UFU, School of Dentistry, Department of Periodontology and Implantology, Uberlândia, MG, Brazil
| | - Gustavo Davi Rabelo
- Universidade Federal de Santa Catarina, Dentistry Department, Florianópolis, SC, Brazil
| | - Nayara Teixeira de Araújo Reis
- Universidade Federal de Uberlândia - UFU, School of Dentistry, Department of Periodontology and Implantology, Uberlândia, MG, Brazil
| | - Priscilla Barbosa Ferreira Soares
- Universidade Federal de Uberlândia - UFU, School of Dentistry, Department of Periodontology and Implantology, Uberlândia, MG, Brazil
| |
Collapse
|
8
|
Ning B, Mustafy T, Londono I, Laporte C, Villemure I. Impact loading intensifies cortical bone (re)modeling and alters longitudinal bone growth of pubertal rats. Biomech Model Mechanobiol 2023:10.1007/s10237-023-01706-5. [PMID: 37000273 DOI: 10.1007/s10237-023-01706-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 02/22/2023] [Indexed: 04/01/2023]
Abstract
Physical exercise is important for musculoskeletal development during puberty, which builds bone mass foundation for later in life. However, strenuous levels of training might bring adverse effects to bone health, reducing longitudinal bone growth. Animal models with various levels of physical exercise were largely used to provide knowledge to clinical settings. Experiments from our previous studies applied different levels of mechanical loading on rat tibia during puberty accompanied by weekly in vivo micro-CT scans. In the present article, we apply 3D image registration-based methods to retrospectively analyze part of the previously acquired micro-CT data. Longitudinal bone growth, growth plate thickness, and cortical bone (re)modeling were evaluated from rats' age of 28-77 days. Our results show that impact loading inhibited proximal bone growth throughout puberty. We hypothesize that impact loading might bring different growth alterations to the distal and proximal growth plates. High impact loading might lead to pathological consequence of osteochondrosis and catch-up growth due to growth inhibition. Impact loading also increased cortical bone (re)modeling before and after the peak proximal bone growth period of young rats, of which the latter case might be caused by the shift from modeling to remodeling as the dominant activity toward the end of rat puberty. We confirm that the tibial endosteum is more mechano-sensitive than the periosteum in response to mechanical loading. To our knowledge, this is the first study to follow up bone growth and bone (re)modeling of young rats throughout the entire puberty with a weekly time interval.
Collapse
Affiliation(s)
- Bohao Ning
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Station Centre-Ville, Montréal, QC, H3C 3A7, Canada
- CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC, H3T 1C5, Canada
| | - Tanvir Mustafy
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Station Centre-Ville, Montréal, QC, H3C 3A7, Canada
- CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC, H3T 1C5, Canada
- Department of Civil Engineering, Military Institute of Science and Technology, Dhaka, 1216, Bangladesh
| | - Irène Londono
- CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC, H3T 1C5, Canada
| | - Catherine Laporte
- CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC, H3T 1C5, Canada
- Department of Electrical Engineering, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montréal, QC, H3C 1K3, Canada
| | - Isabelle Villemure
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Station Centre-Ville, Montréal, QC, H3C 3A7, Canada.
- CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC, H3T 1C5, Canada.
| |
Collapse
|
9
|
Fu M, Li J, Liu M, Yang C, Wang Q, Wang H, Chen B, Fu Q, Sun G. Sericin/Nano-Hydroxyapatite Hydrogels Based on Graphene Oxide for Effective Bone Regeneration via Immunomodulation and Osteoinduction. Int J Nanomedicine 2023; 18:1875-1895. [PMID: 37051313 PMCID: PMC10084881 DOI: 10.2147/ijn.s399487] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 04/05/2023] [Indexed: 04/14/2023] Open
Abstract
Background Immune responses and osteogenesis differentiation induced by implants are crucial for bone tissue regeneration. Consideration of only one of those properties is not sufficient. To investigate the synergistic actions, we designed alginate/graphene oxide/sericin/nanohydroxyapatite (Alg/GO/Ser/nHAP) nanocomposite hydrogels with both osteoimmunomodulatory and osteoinductive activities. This study aimed to explore the effect of hydrogel with osteoimmunomodulatory properties on promoting osteogenesis of bone marrow stem cells (BMSCs). Methods Alg/GO/Ser/nHAP nanocomposite hydrogel was fabricated and was characterized by SEM, FTIR, XRD, stress-strain, rheology, swelling and degradation. After the impact of sericin on M2 macrophage polarization was identified, the BMSCs viability and adhesion were evaluated by CCK8 assay, live/dead staining, cytoskeleton staining. The cell osteogenic differentiation was observed by ALP/ARS staining, immunofluorescence staining, RT-PCR, and Western blotting, respectively. Rat cranial defect model was used to assess osteoimmunomodulatory effects of scaffolds in vivo by micro‑computed tomographic, histological, and immunohistochemical analyses after 8 weeks of healing. Results In vitro experiments revealed that the hydrogel presented desirable mechanical strength, stability, porosity, and biocompatibility. Significantly, sericin and nHAP appeared to exert synergistic effects on bone regeneration. Sericin was observed to inhibit the immune response by inducing macrophage M2-type polarization to create a positive osteoimmune microenvironment, contributing to improving osseointegration at the bone-implant interface to promote osteogenesis. However, the osteogenic differentiation in rat BMSCs was further enhanced by combining nHAP and sericin in the nanocomposite hydrogel. Eventually, the hydrogel was implanted into the rat cranial defect model, assisting in the reduction of local inflammation and efficient bone regeneration. Conclusion The nanocomposite hydrogel stimulated bone formation by the synergistic effects of immunomodulation of macrophage polarization by sericin and direct osteogenic induction by nHAP, demonstrating that such a scaffold that modulates the osteoimmune microenvironment to promote osteogenesis is a promising approach for the development of bone tissue engineering implants in the future.
Collapse
Affiliation(s)
- Mei Fu
- Department of Traumatic Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, People’s Republic of China
| | - Jun Li
- Institute for Regenerative Medicine, Shanghai East Hospital, The Institute for Biomedical Engineering & Nano Science, School of Medicine, Tongji University, Shanghai, People’s Republic of China
| | - Mingchong Liu
- Department of Traumatic Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, People’s Republic of China
| | - Chensong Yang
- Department of Traumatic Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, People’s Republic of China
| | - Qidong Wang
- Department of Traumatic Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, People’s Republic of China
| | - Hongrui Wang
- Department of Orthopedic Trauma, Changhai Hospital, Naval Medical University (Second Military Medical University), Shanghai, People’s Republic of China
| | - Bingdi Chen
- Institute for Regenerative Medicine, Shanghai East Hospital, The Institute for Biomedical Engineering & Nano Science, School of Medicine, Tongji University, Shanghai, People’s Republic of China
| | - Qingge Fu
- Department of Orthopedic Trauma, Changhai Hospital, Naval Medical University (Second Military Medical University), Shanghai, People’s Republic of China
| | - Guixin Sun
- Department of Traumatic Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, People’s Republic of China
- Correspondence: Guixin Sun; Qingge Fu, Email ;
| |
Collapse
|
10
|
Wang S, Yang X, Han Z, Wu X, Fan YB, Sun LW. Changes of cortical bone pores structure and their effects on mechanical properties in tail-suspended rats. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2022.100175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
11
|
Vuković JS, Filipović VV, Babić Radić MM, Vukomanović M, Milivojevic D, Ilic-Tomic T, Nikodinovic-Runic J, Tomić SL. In Vitro and In Vivo Biocompatible and Controlled Resveratrol Release Performances of HEMA/Alginate and HEMA/Gelatin IPN Hydrogel Scaffolds. Polymers (Basel) 2022; 14:polym14204459. [PMID: 36298041 PMCID: PMC9610835 DOI: 10.3390/polym14204459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 10/02/2022] [Accepted: 10/17/2022] [Indexed: 01/19/2023] Open
Abstract
Scaffold hydrogel biomaterials designed to have advantageous biofunctional properties, which can be applied for controlled bioactive agent release, represent an important concept in biomedical tissue engineering. Our goal was to create scaffolding materials that mimic living tissue for biomedical utilization. In this study, two novel series of interpenetrating hydrogel networks (IPNs) based on 2-hydroxyethyl methacrylate/gelatin and 2-hydroxyethyl methacrylate/alginate were crosslinked using N-ethyl-N'-(3-dimethyl aminopropyl)carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS). Characterization included examining the effects of crosslinker type and concentration on structure, morphological and mechanical properties, in vitro swelling, hydrophilicity as well as on the in vitro cell viability (fibroblast cells) and in vivo (Caenorhabditis elegans) interactions of novel biomaterials. The engineered IPN hydrogel scaffolds show an interconnected pore morphology and porosity range of 62.36 to 85.20%, favorable in vitro swelling capacity, full hydrophilicity, and Young's modulus values in the range of 1.40 to 7.50 MPa. In vitro assay on healthy human fibroblast (MRC5 cells) by MTT test and in vivo (Caenorhabditis elegans) survival assays show the advantageous biocompatible properties of novel IPN hydrogel scaffolds. Furthermore, in vitro controlled release study of the therapeutic agent resveratrol showed that these novel scaffolding systems are suitable controlled release platforms. The results revealed that the use of EDC and the combination of EDC/NHS crosslinkers can be applied to prepare and tune the properties of the IPN 2-hydroxyethyl methacrylate/alginate and 2-hydroxyethyl methacrylate/gelatin hydrogel scaffolds series, which have shown great potential for biomedical engineering applications.
Collapse
Affiliation(s)
- Jovana S. Vuković
- University of Belgrade, Faculty of Technology and Metallurgy, Karnegijeva 4, 11000 Belgrade, Serbia
| | - Vuk V. Filipović
- University of Belgrade, Institute of Molecular Genetics and Genetic Engineering, Vojvode Stepe 444a, 11000 Belgrade, Serbia
| | - Marija M. Babić Radić
- University of Belgrade, Faculty of Technology and Metallurgy, Karnegijeva 4, 11000 Belgrade, Serbia
| | - Marija Vukomanović
- Advanced Materials Department, Jožef Stefan Institute, Jamova Cesta 39, 1000 Ljubljana, Slovenia
| | - Dusan Milivojevic
- University of Belgrade, Institute of Molecular Genetics and Genetic Engineering, Vojvode Stepe 444a, 11000 Belgrade, Serbia
| | - Tatjana Ilic-Tomic
- University of Belgrade, Institute of Molecular Genetics and Genetic Engineering, Vojvode Stepe 444a, 11000 Belgrade, Serbia
| | - Jasmina Nikodinovic-Runic
- University of Belgrade, Institute of Molecular Genetics and Genetic Engineering, Vojvode Stepe 444a, 11000 Belgrade, Serbia
| | - Simonida Lj. Tomić
- University of Belgrade, Faculty of Technology and Metallurgy, Karnegijeva 4, 11000 Belgrade, Serbia
- Correspondence: ; Tel.: +381-11-3303-630
| |
Collapse
|
12
|
Therapeutic Targeting Notch2 Protects Bone Micro-Vasculatures from Methotrexate Chemotherapy-Induced Adverse Effects in Rats. Cells 2022; 11:cells11152382. [PMID: 35954226 PMCID: PMC9367713 DOI: 10.3390/cells11152382] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/22/2022] [Accepted: 07/30/2022] [Indexed: 02/04/2023] Open
Abstract
Intensive cancer chemotherapy is well known to cause bone vasculature disfunction and damage, but the mechanism is poorly understood and there is a lack of treatment. Using a rat model of methotrexate (MTX) chemotherapy (five once-daily dosses at 0.75 mg/kg), this study investigated the roles of the Notch2 signalling pathway in MTX chemotherapy-induced bone micro-vasculature impairment. Gene expression, histological and micro-computed tomography (micro-CT) analyses revealed that MTX-induced micro-vasculature dilation and regression is associated with the induction of Notch2 activity in endothelial cells and increased production of inflammatory cytokine tumour necrosis factor alpha (TNFα) from osteoblasts (bone forming cells) and bone marrow cells. Blockade of Notch2 by a neutralising antibody ameliorated MTX adverse effects on bone micro-vasculature, both directly by supressing Notch2 signalling in endothelial cells and indirectly via reducing TNFα production. Furthermore, in vitro studies using rat bone marrow-derived endothelial cell revealed that MTX treatment induces Notch2/Hey1 pathway and negatively affects their ability in migration and tube formation, and Notch2 blockade can partially protect endothelial cell functions from MTX damage.
Collapse
|
13
|
Jia S, Li J, Hu X, Wu X, Gong H. Improved fatigue properties, bone microstructure and blood glucose in type 2 diabetic rats with verapamil treatment. Clin Biomech (Bristol, Avon) 2022; 98:105719. [PMID: 35882095 DOI: 10.1016/j.clinbiomech.2022.105719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 07/07/2022] [Accepted: 07/12/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Type 2 diabetes mellitus is a global epidemic disease, which leads to a severe complication named increased bone fracture risk. This study aimed to explore if verapamil treatment could improve bone quality of type 2 diabetes mellitus. METHODS Rat models of control, diabetes and verapamil treatment with 4/12/24/48 mg/kg/d were established, respectively. Blood glucose was monitored during 12-week treatment, and bilateral tibiae were collected. Microstructural images of bilateral metaphyseal cancellous bone and high-resolution images of cortical bone of left tibial shafts were obtained by micro-computed tomography. Fatigue properties of bone were evaluated via cyclic compressive tests of right tibial shafts. FINDINGS Verapamil treatment had no significant effect on blood glucose, but blood glucose tended to decline with the increase of verapamil-treated time and dose. Compared with controls, osteocyte lacunar and canal porosities in diabetes and verapamil-treated groups were significantly decreased (P < 0.05), trabecular separation and degree of anisotropy were significantly increased (P < 0.05), while trabecular tissue mineral density, trabecular bone volume fraction and trabecular number in verapamil-treated (48 mg/kg/d) group were significantly higher than those in diabetes (P < 0.05). Compared with diabetes, initial compressive elastic moduli in verapamil-treated (12/24/48 mg/kg/d) groups were significantly increased (P < 0.05), while secant modulus degradations in verapamil-treated (24/48 mg/kg/d) groups were significantly decreased (P < 0.05). INTERPRETATION Verapamil could improve bone microstructure and fatigue properties in type 2 diabetic rats; and high-dose verapamil presented a significant effect on improving bone quality. These findings provided a new possibility for preventing the high bone fracture risk of type 2 diabetes mellitus in clinics.
Collapse
Affiliation(s)
- Shaowei Jia
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Jingwen Li
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaorong Hu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaodan Wu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - He Gong
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| |
Collapse
|
14
|
Rothweiler R, Gross C, Bortel E, Früh S, Gerber J, Boller E, Wüster J, Stricker A, Fretwurst T, Iglhaut G, Nahles S, Schmelzeisen R, Hesse B, Nelson K. Comparison of the 3D-Microstructure Between Alveolar and Iliac Bone for Enhanced Bioinspired Bone Graft Substitutes. Front Bioeng Biotechnol 2022; 10:862395. [PMID: 35782504 PMCID: PMC9248932 DOI: 10.3389/fbioe.2022.862395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 05/04/2022] [Indexed: 11/13/2022] Open
Abstract
In oral- and maxillofacial bone augmentation surgery, non-vascularized grafts from the iliac crest demonstrate better clinical performance than alveolar bone grafts. The underlying mechanisms are not fully understood but are essential for the enhancement of bone regeneration scaffolds. Synchrotron Radiation µ-CT at a pixel size of 2.3 μm was used to characterize the gross morphology and the vascular and osteocyte lacuna porosity of patient-matched iliac crest/alveolar bone samples. The results suggest a difference in the spatial distribution of the vascular pore system. Fluid simulations reveal the permeability tensor to be more homogeneous in the iliac crest, indicating a more unidirectional fluid flow in alveolar bone. The average distance between bone mineral and the closest vessel pore boundary was found to be higher in alveolar bone. At the same time, osteocyte lacunae density is higher in alveolar bone, potentially compensating for the longer average distance between the bone mineral and vessel pores. The present study comprehensively quantified and compared the 3D microarchitecture of intraindividual human alveolar and iliac bone. The identified difference in pore network architecture may allow a bone graft from the iliac crest to exhibit higher regeneration potential due to an increased capacity to connect with the surrounding pore network of the residual bone. The results may contribute to understanding the difference in clinical performance when used as bone grafts and are essential for optimization of future scaffold materials.
Collapse
Affiliation(s)
- Rene Rothweiler
- Department of Oral- and Craniomaxillofacial Surgery, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| | - Christian Gross
- Department of Oral- and Craniomaxillofacial Surgery, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| | | | | | | | - Elodie Boller
- European Synchrotron Radiation Facility, Grenoble, France
| | - Jonas Wüster
- Department of Oral and Maxillofacial Surgery, Berlin Institute of Health, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Andres Stricker
- Department of Oral- and Craniomaxillofacial Surgery, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| | - Tobias Fretwurst
- Department of Oral- and Craniomaxillofacial Surgery, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| | - Gerhard Iglhaut
- Department of Oral- and Craniomaxillofacial Surgery, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| | - Susanne Nahles
- Department of Oral and Maxillofacial Surgery, Berlin Institute of Health, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Rainer Schmelzeisen
- Department of Oral- and Craniomaxillofacial Surgery, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| | - Bernhard Hesse
- Xploraytion GmbH, Berlin, Germany
- European Synchrotron Radiation Facility, Grenoble, France
- *Correspondence: Bernhard Hesse, ; Katja Nelson,
| | - Katja Nelson
- Department of Oral- and Craniomaxillofacial Surgery, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
- *Correspondence: Bernhard Hesse, ; Katja Nelson,
| |
Collapse
|
15
|
Allison H, O'Sullivan L, McNamara L. Temporal changes in cortical microporosity during estrogen deficiency associated with perilacunar resorption and osteocyte apoptosis: A pilot study. Bone Rep 2022; 16:101590. [PMID: 35663377 PMCID: PMC9156983 DOI: 10.1016/j.bonr.2022.101590] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 05/13/2022] [Accepted: 05/14/2022] [Indexed: 02/07/2023] Open
Abstract
Osteocytes can actively regulate bone microporosity, through either perilacunar resorption or micropetrosis following apoptosis. Osteocyte apoptosis is more prevalent in estrogen deficiency and changes in the lacunar-canalicular network of osteocytes have been reported. Temporal changes in bone mineralisation and osteocytes cellular strains occur, which might be associated with osteocyte-driven microporosity changes, although time dependant changes in bone microporosity are not yet fully understood. In this pilot study we conducted micro-CT analysis, backscatter electron imaging and histological analysis of femoral cortical bone form an ovariectomized rat model of osteoporosis to investigate whether estrogen deficiency causes temporal changes in lacunar and vascular porosity. We also assessed MMP14 expression, lacunar occupancy and mineral infilling, as indicators of perilacunar resorption and micropetrosis. We report temporal changes in cortical microporosity in estrogen deficiency. Specifically, canalicular and vascular porosity initially increased (4 weeks post-OVX), coinciding with the period of rapid bone loss, whereas in the longer term (14 weeks post-OVX) lacunar and canalicular diameter decreased. Interestingly, these changes coincided with an increased prevalence of empty lacunae and osteocyte lacunae were observed to be more circular with a mineralised border around the lacunar space. In addition we report an increase in MMP14+ osteocytes, which also suggests active matrix degradation by these cells. Together these results provide an insight into the temporal changes in cortical microporosity during estrogen deficiency and suggest the likelihood of occurrence of both perilacunar resorption and osteocyte apoptosis leading to micropetrosis. We propose that microporosity changes arise due to processes driven by distinct populations of osteocytes, which are either actively resorbing their matrix or have undergone apoptosis and are infilling lacunae by micropetrosis.
Collapse
Key Words
- BMDD, Bone mineral density distribution
- BSEM
- BSEM, Backscattered scanning electron microscopy
- BV, Bone volume
- Dm, Diameter
- Estrogen deficiency
- Lacunar
- Lc, Lacunar
- MMP, Matrix metalloproteases
- Micro-CT, Micro computed tomography
- Microporosity
- OVX, Ovariectomized
- PLR, Perilacunar resorption
- Sp, spacing
- TRAP, Tartrate-resistant acid phosphatase
- TV, Total volume
- Tb, Trabecular
- Th, Thickness
- V Ca, Vascular canal
- Vascular canals
- micro-CT
- με, Microstrain (ε ×10−6)
Collapse
Affiliation(s)
- H. Allison
- Mechanobiology and Medical Devices Research Group (MMDRG), Centre for Biomechanics Research (BioMEC), Biomedical Engineering, College of Science and Engineering, National University of Ireland Galway, Ireland
| | - L.M. O'Sullivan
- Mechanobiology and Medical Devices Research Group (MMDRG), Centre for Biomechanics Research (BioMEC), Biomedical Engineering, College of Science and Engineering, National University of Ireland Galway, Ireland
| | - L.M. McNamara
- Mechanobiology and Medical Devices Research Group (MMDRG), Centre for Biomechanics Research (BioMEC), Biomedical Engineering, College of Science and Engineering, National University of Ireland Galway, Ireland
| |
Collapse
|
16
|
Goldsmith M, Crooks SD, Condon SF, Willie BM, Komarova SV. Bone strength and composition in spacefaring rodents: systematic review and meta-analysis. NPJ Microgravity 2022; 8:10. [PMID: 35418128 PMCID: PMC9008045 DOI: 10.1038/s41526-022-00195-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 03/04/2022] [Indexed: 11/09/2022] Open
Abstract
Studying the effects of space travel on bone of experimental animals provides unique advantages, including the ability to perform post-mortem analysis and mechanical testing. To synthesize the available data to assess how much and how consistently bone strength and composition parameters are affected by spaceflight, we systematically identified studies reporting bone health in spacefaring animals from Medline, Embase, Web of Science, BIOSIS, and NASA Technical reports. Previously, we reported the effect of spaceflight on bone architecture and turnover in rodents and primates. For this study, we selected 28 articles reporting bone strength and composition in 60 rats and 60 mice from 17 space missions ranging from 7 to 33 days in duration. Whole bone mechanical indices were significantly decreased in spaceflight rodents, with the percent difference between spaceflight and ground control animals for maximum load of −15.24% [Confidence interval: −22.32, −8.17]. Bone mineral density and calcium content were significantly decreased in spaceflight rodents by −3.13% [−4.96, −1.29] and −1.75% [−2.97, −0.52] respectively. Thus, large deficits in bone architecture (6% loss in cortical area identified in a previous study) as well as changes in bone mass and tissue composition likely lead to bone strength reduction in spaceflight animals.
Collapse
Affiliation(s)
- Matthew Goldsmith
- Research Centre, Shriners Hospital for Children - Canada, Montréal, QC, Canada.,Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montréal, QC, Canada
| | - Sequoia D Crooks
- Research Centre, Shriners Hospital for Children - Canada, Montréal, QC, Canada
| | - Sean F Condon
- Research Centre, Shriners Hospital for Children - Canada, Montréal, QC, Canada
| | - Bettina M Willie
- Research Centre, Shriners Hospital for Children - Canada, Montréal, QC, Canada.,Department of Pediatric Surgery, McGill University, Montréal, QC, Canada
| | - Svetlana V Komarova
- Research Centre, Shriners Hospital for Children - Canada, Montréal, QC, Canada. .,Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montréal, QC, Canada.
| |
Collapse
|
17
|
Ning B, Londono I, Laporte C, Villemure I. Validation of an in vivo micro-CT-based method to quantify longitudinal bone growth of pubertal rats. Bone 2022; 154:116207. [PMID: 34547522 DOI: 10.1016/j.bone.2021.116207] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 09/13/2021] [Accepted: 09/15/2021] [Indexed: 11/02/2022]
Abstract
Bone growth is an essential part of skeletal development during childhood and puberty. Accurately characterizing longitudinal bone growth helps to better understand the determining factors of peak bone mass, which has impacts on bone quality later in life. Animal models were largely used to study longitudinal bone growth. However, the commonly used histology-based method is destructive and unable to follow up the growth curve of live animals in longitudinal experiments. In this study, we validated an in vivo micro-CT-based method against the histology-based method to quantify longitudinal bone growth rates of young rats non-destructively. CD (Sprague Dawley) IGS rats aged 35, 49 and 63 days received the same treatments: two series of repeated in vivo micro-CT scans on their proximal hind limb at a five-day interval, and two calcein injections separated by three days. The longitudinal bone growth rate was quantified by registering time-lapse micro-CT images in 3D, calculating the growth distance on registered images, and dividing the distance by the five-day gap. The growth rate was also evaluated by measuring the 2D distance between consecutive calcein fluorescent bands on microscopic images, divided by the three-day gap. The two methods were both validated independently with reproducible repeated measurements, where the micro-CT-based method showed higher precision. They were also validated against each other with low relative errors and a strong Pearson sample correlation coefficient (0.998), showing a significant (p < 0.0001) linear correlation between paired results. We conclude that the micro-CT-based method can serve as an alternative to the histology-based method for the quantification of longitudinal growth. Thanks to its non-invasive nature and true 3D capability, the micro-CT-based method helps to accommodate in vivo longitudinal animal studies with highly reproducible measurements.
Collapse
Affiliation(s)
- Bohao Ning
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Station Centre-Ville, Montréal, QC H3C 3A7, Canada; CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC H3T 1C5, Canada
| | - Irène Londono
- CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC H3T 1C5, Canada
| | - Catherine Laporte
- CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC H3T 1C5, Canada; Department of Electrical Engineering, École de technologie supérieure, 1100 Notre-Dame Street West, Montréal, QC H3C 1K3, Canada
| | - Isabelle Villemure
- Department of Mechanical Engineering, Polytechnique Montréal, P.O. Box 6079, Station Centre-Ville, Montréal, QC H3C 3A7, Canada; CHU Sainte-Justine Research Centre, 3175 Côte-Sainte-Catherine Road, Montréal, QC H3T 1C5, Canada.
| |
Collapse
|
18
|
Babić Radić MM, Filipović VV, Vukomanović M, Nikodinović Runić J, Tomić SL. Degradable 2-Hydroxyethyl Methacrylate/Gelatin/Alginate Hydrogels Infused by Nanocolloidal Graphene Oxide as Promising Drug Delivery and Scaffolding Biomaterials. Gels 2021; 8:gels8010022. [PMID: 35049557 PMCID: PMC8774307 DOI: 10.3390/gels8010022] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 12/17/2021] [Accepted: 12/22/2021] [Indexed: 12/17/2022] Open
Abstract
The design and evaluation of novel 2-hydroxyethyl methacrylate/gelatin/alginate/graphene oxide hydrogels as innovative scaffolding biomaterials, which concurrently are the suitable drug delivery carrier, was proposed. The hydrogels were prepared by the adapted porogen leaching method; this is also the first time this method has been used to incorporate nanocolloidal graphene oxide through the hydrogel and simultaneously form porous structures. The effects of a material’s composition on its chemical, morphological, mechanical, and swelling properties, as well as on cell viability and in vitro degradation, were assessed using Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), measurements of Young’s modulus, gravimetric method and MTT test, respectively. The engineered hydrogels show good swelling capacity, fully hydrophilic surfaces, tunable porosity (from 56 to 76%) and mechanical properties (from 1.69 to 4.78 MPa), curcumin entrapment efficiency above 99% and excellent curcumin release performances. In vitro cytotoxicity on healthy human fibroblast (MRC5 cells) by MTT test reveal that the materials are nontoxic and biocompatible, proposing novel hydrogels for in vivo clinical evaluation to optimize tissue regeneration treatments by coupling the hydrogels with cells and different active agents to create material/biofactor hybrids with new levels of biofunctionality.
Collapse
Affiliation(s)
- Marija M. Babić Radić
- University of Belgrade, Faculty of Technology and Metallurgy, Karnegijeva 4, 11000 Belgrade, Serbia
- Correspondence: (M.M.B.R.); (S.L.T.); Tel.: +381-11-3303-630 (M.M.B.R. & S.L.T.)
| | - Vuk V. Filipović
- University of Belgrade, Institute for Chemistry, Technology and Metallurgy, Njegoševa 12, 11000 Belgrade, Serbia;
| | - Marija Vukomanović
- Advanced Materials Department, Jožef Stefan Institute, Jamova Cesta 39, 1000 Ljubljana, Slovenia;
| | - Jasmina Nikodinović Runić
- University of Belgrade, Institute of Molecular Genetics and Genetic Engineering, Vojvode Stepe 444a, 11000 Belgrade, Serbia;
| | - Simonida Lj. Tomić
- University of Belgrade, Faculty of Technology and Metallurgy, Karnegijeva 4, 11000 Belgrade, Serbia
- Correspondence: (M.M.B.R.); (S.L.T.); Tel.: +381-11-3303-630 (M.M.B.R. & S.L.T.)
| |
Collapse
|
19
|
The Non-Erythropoietic EPO Analogue Cibinetide Inhibits Osteoclastogenesis In Vitro and Increases Bone Mineral Density in Mice. Int J Mol Sci 2021; 23:ijms23010055. [PMID: 35008482 PMCID: PMC8744753 DOI: 10.3390/ijms23010055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 12/17/2021] [Accepted: 12/18/2021] [Indexed: 01/21/2023] Open
Abstract
The two erythropoietin (EPO) receptor forms mediate different cellular responses to erythropoietin. While hematopoiesis is mediated via the homodimeric EPO receptor (EPOR), tissue protection is conferred via a heteromer composed of EPOR and CD131. In the skeletal system, EPO stimulates osteoclast precursors and induces bone loss. However, the underlying molecular mechanisms are still elusive. Here, we evaluated the role of the heteromeric complex in bone metabolism in vivo and in vitro by using Cibinetide (CIB), a non-erythropoietic EPO analogue that exclusively binds the heteromeric receptor. CIB is administered either alone or in combination with EPO. One month of CIB treatment significantly increased the cortical (~5.8%) and trabecular (~5.2%) bone mineral density in C57BL/6J WT female mice. Similarly, administration of CIB for five consecutive days to female mice that concurrently received EPO on days one and four, reduced the number of osteoclast progenitors, defined by flow cytometry as Lin−CD11b−Ly6Chi CD115+, by 42.8% compared to treatment with EPO alone. In addition, CIB alone or in combination with EPO inhibited osteoclastogenesis in vitro. Our findings introduce CIB either as a stand-alone treatment, or in combination with EPO, as an appealing candidate for the treatment of the bone loss that accompanies EPO treatment.
Collapse
|
20
|
Ajami S, Rodriguez-Florez N, Ong J, Jeelani NUO, Dunaway D, James G, Angullia F, Budden C, Bozkurt S, Ibrahim A, Ferretti P, Schievano S, Borghi A. Mechanical and morphological properties of parietal bone in patients with sagittal craniosynostosis. J Mech Behav Biomed Mater 2021; 125:104929. [PMID: 34773914 DOI: 10.1016/j.jmbbm.2021.104929] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Revised: 10/15/2021] [Accepted: 10/23/2021] [Indexed: 12/13/2022]
Abstract
Limited information is available on the effect of sagittal craniosynostosis (CS) on morphological and material properties of the parietal bone. Understanding these properties would not only provide an insight into bone response to surgical procedures but also improve the accuracy of computational models simulating these surgeries. The aim of the present study was to characterise the mechanical and microstructural properties of the cortical table and diploe in parietal bone of patients affected by sagittal CS. Twelve samples were collected from pediatric patients (11 males, and 1 female; age 5.2 ± 1.3 months) surgically treated for sagittal CS. Samples were imaged using micro-computed tomography (micro-CT); and mechanical properties were extracted by means of micro-CT based finite element modelling (micro-FE) of three-point bending test, calibrated using sample-specific experimental data. Reference point indentation (RPI) was used to validate the micro-FE output. Bone samples were classified based on their macrostructure as unilaminar or trilaminar (sandwich) structure. The elastic moduli obtained using RPI and micro-FE approaches for cortical tables (ERPI 3973.33 ± 268.45 MPa and Emicro-FE 3438.11 ± 387.38 MPa) in the sandwich structure and diploe (ERPI1958.17 ± 563.79 MPa and Emicro-FE 1960.66 ± 492.44 MPa) in unilaminar samples were in strong agreement (r = 0.86, p < .01). We found that the elastic modulus of cortical tables and diploe were correlated with bone mineral density. Changes in the microstructure and mechanical properties of bone specimens were found to be irrespective of patients' age. Although younger patients are reported to benefit more from surgical intervention as skull is more malleable, understanding the material properties is critical to better predict the surgical outcome in patients <1 year old since age-related changes were minimal.
Collapse
Affiliation(s)
- Sara Ajami
- UCL Great Ormond Street Institute of Child Health, London WC1N 1EH, United Kingdom.
| | - Naiara Rodriguez-Florez
- Universidad de Navarra, TECNUN Escuela de Ingenieros, Spain; Ikerbasque, Basque Foundation of Science, Spain
| | - Juling Ong
- Craniofacial Unit, Great Ormond Street Hospital, London WC1N 3JH, United Kingdom
| | | | - David Dunaway
- Craniofacial Unit, Great Ormond Street Hospital, London WC1N 3JH, United Kingdom
| | - Greg James
- Craniofacial Unit, Great Ormond Street Hospital, London WC1N 3JH, United Kingdom
| | - Freida Angullia
- Craniofacial Unit, Great Ormond Street Hospital, London WC1N 3JH, United Kingdom
| | - Curtis Budden
- Craniofacial Unit, Great Ormond Street Hospital, London WC1N 3JH, United Kingdom
| | - Selim Bozkurt
- UCL Great Ormond Street Institute of Child Health, London WC1N 1EH, United Kingdom; UCL Institute of Cardiovascular Science, London WC1E 6BT, United Kingdom
| | - Amel Ibrahim
- Biomaterials and Biomimetics, NYU College of Dentistry, United States
| | - Patrizia Ferretti
- UCL Great Ormond Street Institute of Child Health, London WC1N 1EH, United Kingdom
| | - Silvia Schievano
- UCL Great Ormond Street Institute of Child Health, London WC1N 1EH, United Kingdom
| | - Alessandro Borghi
- UCL Great Ormond Street Institute of Child Health, London WC1N 1EH, United Kingdom
| |
Collapse
|
21
|
Batoon L, Millard SM, Raggatt LJ, Wu AC, Kaur S, Sun LWH, Williams K, Sandrock C, Ng PY, Irvine KM, Bartnikowski M, Glatt V, Pavlos NJ, Pettit AR. Osteal macrophages support osteoclast-mediated resorption and contribute to bone pathology in a postmenopausal osteoporosis mouse model. J Bone Miner Res 2021; 36:2214-2228. [PMID: 34278602 DOI: 10.1002/jbmr.4413] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 06/29/2021] [Accepted: 07/14/2021] [Indexed: 11/08/2022]
Abstract
Osteal macrophages (osteomacs) support osteoblast function and promote bone anabolism, but their contribution to osteoporosis has not been explored. Although mouse ovariectomy (OVX) models have been repeatedly used, variation in strain, experimental design and assessment modalities have contributed to no single model being confirmed as comprehensively replicating the full gamut of osteoporosis pathological manifestations. We validated an OVX model in adult C3H/HeJ mice and demonstrated that it presents with human postmenopausal osteoporosis features with reduced bone volume in axial and appendicular bone and bone loss in both trabecular and cortical bone including increased cortical porosity. Bone loss was associated with increased osteoclasts on trabecular and endocortical bone and decreased osteoblasts on trabecular bone. Importantly, this OVX model was characterized by delayed fracture healing. Using this validated model, we demonstrated that osteomacs are increased post-OVX on both trabecular and endocortical bone. Dual F4/80 (pan-macrophage marker) and tartrate-resistant acid phosphatase (TRAP) staining revealed osteomacs frequently located near TRAP+ osteoclasts and contained TRAP+ intracellular vesicles. Using an in vivo inducible macrophage depletion model that does not simultaneously deplete osteoclasts, we observed that osteomac loss was associated with elevated extracellular TRAP in bone marrow interstitium and increased serum TRAP. Using in vitro high-resolution confocal imaging of mixed osteoclast-macrophage cultures on bone substrate, we observed macrophages juxtaposed to osteoclast basolateral functional secretory domains scavenging degraded bone byproducts. These data demonstrate a role for osteomacs in supporting osteoclastic bone resorption through phagocytosis and sequestration of resorption byproducts. Overall, our data expose a novel role for osteomacs in supporting osteoclast function and provide the first evidence of their involvement in osteoporosis pathogenesis. © 2021 American Society for Bone and Mineral Research (ASBMR).
Collapse
Affiliation(s)
- Lena Batoon
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Susan M Millard
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Liza J Raggatt
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Andy C Wu
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Simranpreet Kaur
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Lucas W H Sun
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Kyle Williams
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Cheyenne Sandrock
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Pei Ying Ng
- Bone Biology and Disease Laboratory, School of Biomedical Sciences, The University of Western Australia, Nedlands, Western Australia, Australia
| | - Katharine M Irvine
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| | - Michal Bartnikowski
- Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Vaida Glatt
- Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Queensland, Australia.,Orthopaedic Surgery Department, University of Texas Health Science Center San Antonio, San Antonio, TX, USA
| | - Nathan J Pavlos
- Bone Biology and Disease Laboratory, School of Biomedical Sciences, The University of Western Australia, Nedlands, Western Australia, Australia
| | - Allison R Pettit
- Mater Research Institute-The University of Queensland, Translational Research Institute, Woolloongabba, Queensland, Australia
| |
Collapse
|
22
|
Tits A, Plougonven E, Blouin S, Hartmann MA, Kaux JF, Drion P, Fernandez J, van Lenthe GH, Ruffoni D. Local anisotropy in mineralized fibrocartilage and subchondral bone beneath the tendon-bone interface. Sci Rep 2021; 11:16534. [PMID: 34400706 PMCID: PMC8367976 DOI: 10.1038/s41598-021-95917-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 08/02/2021] [Indexed: 12/19/2022] Open
Abstract
The enthesis allows the insertion of tendon into bone thanks to several remarkable strategies. This complex and clinically relevant location often features a thin layer of fibrocartilage sandwiched between tendon and bone to cope with a highly heterogeneous mechanical environment. The main purpose of this study was to investigate whether mineralized fibrocartilage and bone close to the enthesis show distinctive three-dimensional microstructural features, possibly to enable load transfer from tendon to bone. As a model, the Achilles tendon-calcaneus bone system of adult rats was investigated with histology, backscattered electron imaging and micro-computed tomography. The microstructural porosity of bone and mineralized fibrocartilage in different locations including enthesis fibrocartilage, periosteal fibrocartilage and bone away from the enthesis was characterized. We showed that calcaneus bone presents a dedicated protrusion of low porosity where the tendon inserts. A spatially resolved analysis of the trabecular network suggests that such protrusion may promote force flow from the tendon to the plantar ligament, while partially relieving the trabecular bone from such a task. Focusing on the tuberosity, highly specific microstructural aspects were highlighted. Firstly, the interface between mineralized and unmineralized fibrocartilage showed the highest roughness at the tuberosity, possibly to increase failure resistance of a region carrying large stresses. Secondly, fibrochondrocyte lacunae inside mineralized fibrocartilage, in analogy with osteocyte lacunae in bone, had a predominant alignment at the enthesis and a rather random organization away from it. Finally, the network of subchondral channels inside the tuberosity was highly anisotropic when compared to contiguous regions. This dual anisotropy of subchondral channels and cell lacunae at the insertion may reflect the alignment of the underlying collagen network. Our findings suggest that the microstructure of fibrocartilage may be linked with the loading environment. Future studies should characterize those microstructural aspects in aged and or diseased conditions to elucidate the poorly understood role of bone and fibrocartilage in enthesis-related pathologies.
Collapse
Affiliation(s)
- Alexandra Tits
- Mechanics of Biological and Bioinspired Materials Laboratory, Department of Aerospace and Mechanical Engineering, University of Liège, Quartier Polytech 1, Allée de la Découverte 9, 4000, Liège, Belgium
| | - Erwan Plougonven
- Chemical Engineering Department, University of Liège, Liège, Belgium
| | - Stéphane Blouin
- Ludwig Boltzmann Institute of Osteology, Hanusch Hospital of OEGK and AUVA Trauma Centre Meidling, 1st Medical Department Hanusch Hospital, Vienna, Austria
| | - Markus A Hartmann
- Ludwig Boltzmann Institute of Osteology, Hanusch Hospital of OEGK and AUVA Trauma Centre Meidling, 1st Medical Department Hanusch Hospital, Vienna, Austria
| | - Jean-François Kaux
- Department of Physical Medicine and Sports Traumatology, University of Liège and University Hospital of Liège, Liège, Belgium
| | - Pierre Drion
- Experimental Surgery Unit, GIGA and Credec, University of Liege, Liege, Belgium
| | - Justin Fernandez
- Auckland Bioengineering Institute and Department of Engineering Science, University of Auckland, Auckland, New Zealand
| | | | - Davide Ruffoni
- Mechanics of Biological and Bioinspired Materials Laboratory, Department of Aerospace and Mechanical Engineering, University of Liège, Quartier Polytech 1, Allée de la Découverte 9, 4000, Liège, Belgium.
| |
Collapse
|
23
|
Liu F, Gao C, Wang W, Hu J, Huang Z, Liang M, Li S. miR-137/ERRα axis mediates chemoresistance of nasopharyngeal carcinoma cells. J Cell Commun Signal 2021; 16:103-113. [PMID: 34196940 DOI: 10.1007/s12079-021-00634-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 06/23/2021] [Indexed: 10/21/2022] Open
Abstract
Nasopharyngeal carcinoma (NPC) is the most common malignant tumor of the head and neck region and is characterized by an increased risk of developing chemoresistance after treatment. The present study demonstrated that estrogen-related receptor α (ERRα) was upregulated in cisplatin- and fluorouracil-resistant NPC cells. In addition, ERRα knockdown or treatment of cells with the ERRα inverse agonist XCT-790 attenuated the chemoresistance of NPC cells. Mechanistically, the increased expression of ERRα in chemoresistant cells was associated with enhanced mRNA stability. Bioinformatics analysis for screening microRNAs (miRs) regulating the expression of ERRα revealed that miR-137 was downregulated in chemoresistant NPC cells. Additionally, transfection of cells with miR-137 mimics reduced ERRα mRNA stability and increased the chemosensitivity of NPC cells. Furthermore, ERRα knockdown reduced glucose consumption, and lactate and ATP production rates in chemoresistant cells. The aforementioned findings suggested that the miR-137/ERRα-mediated metabolic programming could be involved in the chemoresistance of NPC cells.
Collapse
Affiliation(s)
- Fei Liu
- Department of Otolaryngology, Shenzhen Nanshan People's Hospital and The 6Th Affiliated Hospital of Shenzhen University Health Science Center, No.89 Taoyuan Road, Nanshan District, Shenzhen City, 518000, Guangdong Province, People's Republic of China
| | - Chunsheng Gao
- Department of Otolaryngology, Shenzhen Nanshan People's Hospital and The 6Th Affiliated Hospital of Shenzhen University Health Science Center, No.89 Taoyuan Road, Nanshan District, Shenzhen City, 518000, Guangdong Province, People's Republic of China
| | - Wenjuan Wang
- Department of Emergency Intensive Care Unit, Shenzhen Nanshan People's Hospital and The 6Th Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen City, 518000, Guangdong Province, People's Republic of China
| | - Jing Hu
- Department of Otolaryngology, Shenzhen Nanshan People's Hospital and The 6Th Affiliated Hospital of Shenzhen University Health Science Center, No.89 Taoyuan Road, Nanshan District, Shenzhen City, 518000, Guangdong Province, People's Republic of China
| | - Zuofeng Huang
- Department of Otolaryngology, Shenzhen Nanshan People's Hospital and The 6Th Affiliated Hospital of Shenzhen University Health Science Center, No.89 Taoyuan Road, Nanshan District, Shenzhen City, 518000, Guangdong Province, People's Republic of China
| | - Meng Liang
- Department of Otolaryngology, Shenzhen Nanshan People's Hospital and The 6Th Affiliated Hospital of Shenzhen University Health Science Center, No.89 Taoyuan Road, Nanshan District, Shenzhen City, 518000, Guangdong Province, People's Republic of China
| | - Shuo Li
- Department of Otolaryngology, Shenzhen Nanshan People's Hospital and The 6Th Affiliated Hospital of Shenzhen University Health Science Center, No.89 Taoyuan Road, Nanshan District, Shenzhen City, 518000, Guangdong Province, People's Republic of China.
| |
Collapse
|
24
|
Gatti V, Gelbs MJ, Guerra RB, Gerber MB, Fritton SP. Interstitial fluid velocity is decreased around cortical bone vascular pores and depends on osteocyte position in a rat model of disuse osteoporosis. Biomech Model Mechanobiol 2021; 20:1135-1146. [PMID: 33666792 DOI: 10.1007/s10237-021-01438-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Accepted: 02/15/2021] [Indexed: 10/22/2022]
Abstract
Muscle paralysis induced with botulinum toxin (Botox) injection increases vascular porosity and reduces osteocyte lacunar density in the tibial cortical bone of skeletally mature rats. These morphological changes potentially affect interstitial fluid flow in the lacunar-canalicular porosity, which is thought to play a role in osteocyte mechanotransduction. The aim of this study was to investigate the effects of disuse-induced morphological changes on interstitial fluid velocity around osteocytes in the bone cortex. Micro-CT images from a previous study that quantified the effects of Botox-induced muscle paralysis on bone microarchitecture in skeletally mature rats were used to create high-resolution, animal-specific finite element models that included the vascular pores and osteocyte lacunae within the tibial metaphysis of Botox-injected (BTX, n = 8) and saline-injected control (CTRL, n = 8) groups. To quantify fluid flow, lacunar and canalicular porosities were modeled as fluid-saturated poroelastic materials, and boundary conditions were applied to simulate physiological loading. This modeling approach allowed a detailed quantification of the fluid flow velocities around osteocytes in a relatively large volume of bone tissue. The analysis demonstrated that interstitial fluid velocity at the vascular pore surfaces was significantly lower in BTX compared to CTRL because of the decreased vascular canal separation. No significant differences in average fluid velocity were observed at the osteocyte lacunae and no correlation was found between the fluid velocity and the lacunar density, which was significantly lower in BTX. Instead, the lacunar fluid velocity was dependent on the osteocyte's specific position in the bone cortex and its proximity to a vascular pore.
Collapse
Affiliation(s)
- Vittorio Gatti
- Department of Biomedical Engineering, The City College of New York, New York, NY, USA
| | - Michelle J Gelbs
- Department of Biomedical Engineering, The City College of New York, New York, NY, USA
| | - Rodrigo B Guerra
- Department of Biomedical Engineering, The City College of New York, New York, NY, USA
| | - Michael B Gerber
- Department of Biomedical Engineering, The City College of New York, New York, NY, USA
| | - Susannah P Fritton
- Department of Biomedical Engineering, The City College of New York, New York, NY, USA.
| |
Collapse
|
25
|
Radlanski RJ, Weinhold J, Jerichow S, Mehner M, Schwandt H, Keilig L, Bourauel C. A method to calibrate fetal μCT scans using histological sections from the same specimens. Ann Anat 2021; 237:151725. [PMID: 33798695 DOI: 10.1016/j.aanat.2021.151725] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/22/2021] [Accepted: 03/04/2021] [Indexed: 01/04/2023]
Abstract
Craniofacial morphogenesis is an intricate developmental process in 3D, which therefore merits visualization and investigation in 3D. To better understand the process, we utilize μCT imaging, and describe a method to calibrate each cone beam μCT individually. Calibration is necessary, because during development, fetuses undergo tissue differentiation, which affects the acquisition process for radiographic images. Additionally, tissue fixation and conservation agents may influence the physical properties of the specimens and may affect image acquisition. After taking a μCT scan from each specimen, we separated a horizontal slice from each neck (which is inconsequential to our question with relation to the whole head). These neck specimens were prepared as horizontal histological serial sections and stained. With these as a reference, the μCT visualization parameters could be adjusted until they matched the selected virtual section planes, which correspond exactly to the planes of the histological sections with a precision (pixel size) of 0.69μm.
Collapse
Affiliation(s)
- R J Radlanski
- Charité - Campus Benjamin Franklin at Freie Universität Berlin, Center for Dental and Craniofacial Sciences, Dept. of Craniofacial Developmental Biology, Assmannshauser Str. 4-6, 14197 Berlin, Germany.
| | - J Weinhold
- Technische Universität Berlin, Fakultät II Mathematik und Naturwissenschaften, Institut für Mathematik, 3D-Labor, Sekr. MA 6-4, Straße des 17. Juni 136, 10623 Berlin, Germany
| | - S Jerichow
- Charité - Campus Benjamin Franklin at Freie Universität Berlin, Center for Dental and Craniofacial Sciences, Dept. of Craniofacial Developmental Biology, Assmannshauser Str. 4-6, 14197 Berlin, Germany; Technische Universität Berlin, Fakultät II Mathematik und Naturwissenschaften, Institut für Mathematik, 3D-Labor, Sekr. MA 6-4, Straße des 17. Juni 136, 10623 Berlin, Germany
| | - M Mehner
- Technische Universität Berlin, Fakultät II Mathematik und Naturwissenschaften, Institut für Mathematik, 3D-Labor, Sekr. MA 6-4, Straße des 17. Juni 136, 10623 Berlin, Germany
| | - H Schwandt
- Technische Universität Berlin, Fakultät II Mathematik und Naturwissenschaften, Institut für Mathematik, 3D-Labor, Sekr. MA 6-4, Straße des 17. Juni 136, 10623 Berlin, Germany
| | - L Keilig
- Universitätsklinikum Bonn, Oralmedizinische Technologie, Zentrum für Zahn-, Mund- und Kieferheilkunde, Welschnonnenstr. 17, 53111 Bonn, Germany
| | - C Bourauel
- Universitätsklinikum Bonn, Oralmedizinische Technologie, Zentrum für Zahn-, Mund- und Kieferheilkunde, Welschnonnenstr. 17, 53111 Bonn, Germany
| |
Collapse
|
26
|
Bones of teleost fish demonstrate high fracture strain. J Biomech 2021; 120:110341. [PMID: 33743397 DOI: 10.1016/j.jbiomech.2021.110341] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 01/04/2021] [Accepted: 02/12/2021] [Indexed: 11/22/2022]
Abstract
The endoskeleton of teleosts (bony fish) includes a vertebral spine with articulating rib bones (RBs) similar to humans and further encompasses mineralized tissues that are not found in mammals, including intermuscular bones (IBs). RBs form through endochondral ossification and protect the inner organs, and IBs form through intramembranous ossification within the myosepta and play a role in force transmission and propulsion during locomotion. Based on previous findings suggesting that IBs show a much higher ability for fracture strain compared to mammalian bones, this study aims to investigate whether this ability is general to teleost bones or specific to IBs. We analyzed RBs and IBs of 25 North Atlantic Herring fish. RBs were analyzed using micro-mechanical tensile testing and micro-computed tomography, and both RB and IB were additionally analyzed with Raman spectroscopy. Based on our previous results from IB, we found that RBs are more elastically deformable (on average, 50% higher yield strain and 115% higher elastic work) and stronger (55% higher fracture stress) than values reported for IBs. However, these differences were neither associated with a higher Young's modulus nor a higher degree of mineralization in RBs. Astonishingly, RBs and IBs showed similar fracture strains (12-15% on average, reaching up to 20%), reflecting a much higher ability for tensile deformation than reported for mammalian bone, and further highlighting the biomimetic potential of teleost fish bones for inspiring innovative biomaterials.
Collapse
|
27
|
Coffman AA, Basta-Pljakic J, Guerra RM, Ebetino FH, Lundy MW, Majeska RJ, Schaffler MB. A Bisphosphonate With a Low Hydroxyapatite Binding Affinity Prevents Bone Loss in Mice After Ovariectomy and Reverses Rapidly With Treatment Cessation. JBMR Plus 2021; 5:e10476. [PMID: 33869992 PMCID: PMC8046044 DOI: 10.1002/jbm4.10476] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 02/04/2021] [Indexed: 12/30/2022] Open
Abstract
Bisphosphonates (BPs) are a mainstay of osteoporosis treatment; however, concerns about bone health based on oversuppression of remodeling remain. Long‐term bone remodeling suppression adversely affects bone material properties with microdamage accumulation and reduced fracture toughness in animals and increases in matrix mineralization and atypical femur fractures in patients. Although a “drug holiday” from BPs to restore remodeling and improve bone quality seems reasonable, clinical BPs have long functional half‐lives because of their high hydroxyapatite (HAP) binding affinities. This places a practical limit on the reversibility and effectiveness of a drug holiday. BPs with low HAP affinity and strong osteoclast inhibition potentially offer an alternative approach; their antiresorptive effect should reverse rapidly when dosing is discontinued. This study tested this concept using NE‐58025, a BP with low HAP affinity and moderate osteoclast inhibition potential. Young adult female C57Bl/6 mice were ovariectomized (OVX) and treated with NE‐58025, risedronate, or PBS vehicle for 3 months to test effectiveness in preventing long‐term bone loss. Bone microarchitecture, histomorphometry, and whole‐bone mechanical properties were assessed. To test reversibility, OVX mice were similarly treated for 3 months, treatment was stopped, and bone was assessed up to 3 months post‐treatment. NE‐58025 and RIS inhibited long‐term OVX‐induced bone loss, but NE‐58025 antiresorptive effects were more pronounced. Withdrawing NE‐58025 treatment led to the rapid onset of trabecular resorption with a 200% increase in osteoclast surface and bone loss within 1 month. Cessation of risedronate treatment did not lead to increases in resorption indices or bone loss. These results show that NE‐58025 prevents OVX‐induced bone loss, and its effects reverse quickly following cessation treatment in vivo. Low‐HAP affinity BPs may have use as reversible, antiresorptive agents with a rapid on/off profile, which may be useful for maintaining bone health with long‐term BP treatment. © 2021 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Abigail A Coffman
- Department of Biomedical Engineering The City College of New York New York NY USA
| | - Jelena Basta-Pljakic
- Department of Biomedical Engineering The City College of New York New York NY USA
| | - Rosa M Guerra
- Department of Biomedical Engineering The City College of New York New York NY USA
| | - Frank H Ebetino
- Department of Chemistry University of Rochester Rochester NY USA.,BioVinc, LLC Pasadena CA USA
| | - Mark W Lundy
- BioVinc, LLC Pasadena CA USA.,Department of Anatomy and Cell Biology Indiana University Indianapolis IN USA
| | - Robert J Majeska
- Department of Biomedical Engineering The City College of New York New York NY USA
| | - Mitchell B Schaffler
- Department of Biomedical Engineering The City College of New York New York NY USA
| |
Collapse
|
28
|
Requist MR, Sripanich Y, Peterson AC, Rolvien T, Barg A, Lenz AL. Semi-automatic micro-CT segmentation of the midfoot using calibrated thresholds. Int J Comput Assist Radiol Surg 2021; 16:387-396. [PMID: 33606178 DOI: 10.1007/s11548-021-02318-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 01/19/2021] [Indexed: 10/22/2022]
Abstract
PURPOSE In the field of skeletal research, accurate and reliable segmentation methods are necessary for quantitative micro-CT analysis to assess bone quality. We propose a method of semi-automatic image segmentation of the midfoot, using the cuneiform bones as a model, based on thresholds set by phantom calibration that allows reproducible results in low cortical thickness bones. METHODS Manual and semi-automatic segmentation methods were compared in micro-CT scans of the medial and intermediate cuneiforms of 24 cadaveric specimens. The manual method used intensity thresholds, hole filling, and manual cleanup. The semi-automatic method utilized calibrated bone and soft tissue thresholds Boolean subtraction to cleanly identify edges before hole filling. Intra- and inter-rater reliability was tested for the semi-automatic method in all specimens. Mask volume and average bone mineral density (BMD) were measured for all masks, and the three-dimensional models were compared to the initial semi-automatic segmentation using an unsigned distance part comparison analysis. Segmentation methods were compared with paired t-tests with significance level 0.05, and reliability was analyzed by calculating intra-class correlation coefficients. RESULTS There were statistically significant differences in mask volume and BMD between the manual and semi-automatic segmentation methods in both bones. The intra- and inter-reliability was excellent for mask volume and bone density in both bones. Part comparisons showed a higher maximum distance between surfaces for the manual segmentation than the repeat semi-automatic segmentations. CONCLUSION We developed a semi-automatic micro-CT segmentation method based on calibrated thresholds. This method was designed specifically for use in bones with high rates of curvature and low cortical bone density, such as the cuneiforms, where traditional threshold-based segmentation is more challenging. Our method shows improvement over manual segmentation and was highly reliable, making it appropriate for use in quantitative micro-CT analysis.
Collapse
Affiliation(s)
- Melissa R Requist
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.,Department of Biomedical Engineering, University of Arizona, 1127 E James E Rogers Way, Tucson, AZ, 85721, USA
| | - Yantarat Sripanich
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.,Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, 315 Rajavithi Road, Tung Phayathai, Ratchathewi, Bangkok, 10400, Thailand
| | - Andrew C Peterson
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA
| | - Tim Rolvien
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Alexej Barg
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA. .,Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| | - Amy L Lenz
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.
| |
Collapse
|
29
|
Schmidutz F, Milz S, Schiuma D, Richards RG, Windolf M, Sprecher CM. Cortical parameters predict bone strength at the tibial diaphysis, but are underestimated by HR-pQCT and μCT compared to histomorphometry. J Anat 2020; 238:669-678. [PMID: 33084063 PMCID: PMC7855080 DOI: 10.1111/joa.13337] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 09/05/2020] [Accepted: 09/28/2020] [Indexed: 12/16/2022] Open
Abstract
Cortical bone and its microstructure are crucial for bone strength, especially at the long bone diaphysis. However, it is still not well‐defined how imaging procedures can be used as predictive tools for mechanical bone properties. This study evaluated the capability of several high‐resolution imaging techniques to capture cortical bone morphology and assessed the correlation with the bone's mechanical properties. The microstructural properties (cortical thickness [Ct.Th], porosity [Ct.Po], area [Ct.Ar]) of 11 female tibial diaphysis (40–90 years) were evaluated by dual‐energy X‐ray absorptiometry (DXA), high‐resolution peripheral‐quantitative‐computed‐tomography (HR‐pQCT), micro‐CT (μCT) and histomorphometry. Stiffness and maximal torque to failure were determined by mechanical testing. T‐Scores determined by DXA ranged from 0.6 to −5.6 and a lower T‐Score was associated with a decrease in Ct.Th (p ≤ 0.001) while the Ct.Po (p ≤ 0.007) increased, and this relationship was independent of the imaging method. With decreasing T‐Score, histology showed an increase in Ct.Po from the endosteal to the periosteal side (p = 0.001) and an exponential increase in the ratio of osteons at rest to those after remodelling. However, compared to histomorphometry, HR‐pQCT and μCT underestimated Ct.Po and Ct.Th. A lower T‐Score was also associated with significantly reduced stiffness (p = 0.031) and maximal torque (p = 0.006). Improving the accuracy of Ct.Po and Ct.Th did not improve prediction of the mechanical properties, which was most closely related to geometry (Ct.Ar). The ex‐vivo evaluation of mechanical properties correlated with all imaging modalities, with Ct.Th and Ct.Po highly correlated with the T‐Score of the tibial diaphysis. Cortical microstructural changes were underestimated with the lower resolution of HR‐pQCT and μCT compared to the histological ‘gold standard’. The increased accuracy did not result in an improved prediction for local bone strength in this study, which however might be related to the limited number of specimens and thus needs to be evaluated in a larger collective.
Collapse
Affiliation(s)
- Florian Schmidutz
- AO Research Institute Davos, Davos, Switzerland.,Department of Orthopaedic Surgery, University of Munich (LMU), Munich, Germany.,University of Tübingen, BG Trauma Center, Tübingen, Germany
| | - Stefan Milz
- Department of Anatomy II, University of Munich (LMU), Munich, Germany
| | | | | | | | | |
Collapse
|
30
|
Zimmermann EA, Fiedler IAK, Busse B. Breaking new ground in mineralized tissue: Assessing tissue quality in clinical and laboratory studies. J Mech Behav Biomed Mater 2020; 113:104138. [PMID: 33157423 DOI: 10.1016/j.jmbbm.2020.104138] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 09/15/2020] [Accepted: 10/07/2020] [Indexed: 02/07/2023]
Abstract
Mineralized tissues, such as bone and teeth, have extraordinary mechanical properties of both strength and toughness. This mechanical behavior originates from deformation and fracture resistance mechanisms in their multi-scale structure. The term quality describes the matrix composition, multi-scale structure, remodeling dynamics, water content, and micro-damage accumulation in the tissue. Aging and disease result in changes in the tissue quality that may reduce strength and toughness and lead to elevated fracture risk. Therefore, the capability to measure the quality of mineralized tissues provides critical information on disease progression and mechanical integrity. Here, we provide an overview of clinical and laboratory-based techniques to assess the quality of mineralized tissues in health and disease. Current techniques used in clinical settings include radiography-based (radiographs, dual energy x-ray absorptiometry, EOS) and x-ray tomography-based methods (high resolution peripheral quantitative computed tomography, cone beam computed tomography). In the laboratory, tissue quality can be investigated in ex vivo samples with x-ray imaging (micro and nano-computed tomography, x-ray microscopy), electron microscopy (scanning/transmission electron imaging (SEM/STEM), backscattered scanning electron microscopy, Focused Ion Beam-SEM), light microscopy, spectroscopy (Raman spectroscopy and Fourier transform infrared spectroscopy) and assessment of mechanical behavior (mechanical testing, fracture mechanics and reference point indentation). It is important for clinicians and basic science researchers to be aware of the techniques available in different types of research. While x-ray imaging techniques translated to the clinic have provided exceptional advancements in patient care, the future challenge will be to incorporate high-resolution laboratory-based bone quality measurements into clinical settings to broaden the depth of information available to clinicians during diagnostics, treatment and management of mineralized tissue pathologies.
Collapse
Affiliation(s)
| | - Imke A K Fiedler
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Björn Busse
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| |
Collapse
|
31
|
Pathmanapan S, Periyathambi P, Anandasadagopan SK. Fibrin hydrogel incorporated with graphene oxide functionalized nanocomposite scaffolds for bone repair — In vitro and in vivo study. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2020; 29:102251. [DOI: 10.1016/j.nano.2020.102251] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 06/15/2020] [Accepted: 06/17/2020] [Indexed: 10/24/2022]
|
32
|
Zelaya-Lainez L, Kariem H, Nischkauer W, Limbeck A, Hellmich C. "Variances" and "in-variances" in hierarchical porosity and composition, across femoral tissues from cow, horse, ostrich, emu, pig, rabbit, and frog. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 117:111234. [PMID: 32919621 DOI: 10.1016/j.msec.2020.111234] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 06/10/2020] [Accepted: 06/21/2020] [Indexed: 10/24/2022]
Abstract
It is very well known that bone is a hierarchically organized material produced by bone cells residing in the fluid environments filling (larger) vascular pores and (smaller) lacunar pores. The extracellular space consists of hydroxyapatite crystals, collagen type I molecules, and water with non-collageneous organics. It is less known to which extent the associated quantities (mineral, organic, and water concentrations; vascular, lacunar, and extracellular porosities) vary across species, organs, and ages. We here investigate the aforementioned quantities across femoral shaft tissues from cow, horse, emu, frog, ostrich, pig, and rabbit; by means of light microscopy and dehydration-demineralization tests; thereby revealing interesting invariances: The extracellular volume fractions of organic matter turn out to be similar across all tested non-amphibian tissues; as do the extracellular volume fractions of hydroxyapatite across all tested mammals. Hence, the chemical composition of the femoral extracellular bone matrix is remarkably "invariant" across differently aged mammals; while the water content shows significant variations, as does the partitions of water between the different pore spaces. The latter exhibit strikingly varying morphologies as well. This finding adds to the ample "universal patterns" in the sense of evolutionary developmental biology; and it provides interesting design requirements for the development of novel biomimetic tissue engineering solutions.
Collapse
Affiliation(s)
- Luis Zelaya-Lainez
- Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Karlsplatz 13/E202, 1040 Vienna, Austria
| | - Hawraa Kariem
- Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Karlsplatz 13/E202, 1040 Vienna, Austria
| | - Winfried Nischkauer
- Institute of Chemical Technologies and Analytics, Division of Instrumental Analytical Chemistry, TU Wien - Vienna University of Technology, Getreidemarkt 9/164, 1060 Vienna, Austria
| | - Andreas Limbeck
- Institute of Chemical Technologies and Analytics, Division of Instrumental Analytical Chemistry, TU Wien - Vienna University of Technology, Getreidemarkt 9/164, 1060 Vienna, Austria
| | - Christian Hellmich
- Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Karlsplatz 13/E202, 1040 Vienna, Austria.
| |
Collapse
|
33
|
Snoddy AME, Miszkiewicz JJ, Loch C, Tromp M, Buckley HR. An image analysis protocol for the quantification of interglobular dentine in anthropological tooth sections. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2020; 174:144-148. [PMID: 32914865 DOI: 10.1002/ajpa.24143] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 08/19/2020] [Accepted: 08/21/2020] [Indexed: 01/02/2023]
Abstract
The histological identification of interglobular dentine (IGD) in archeological human remains with macroscopic evidence of rickets has opened a promising new avenue for the investigation of metabolic disease in the past. Recent paleopathological studies have shown that histological analysis of archeological human teeth may allow the identification of periods of vitamin D deficiency occurring within very narrow developmental windows, yielding new information on the seasonality or even maternal-fetal transmission of this disease. However, currently available techniques for recording IGD rely on subjective scoring systems or visual estimations, potentially leaving them open to inter and intra-observer error and rendering comparisons of datasets difficult. Here we describe a new imaging protocol that utilizes open access software and may yield more objective and quantitative data on the amount of IGD present within a dentinal region of interest. We demonstrate that grayscale histograms in FIJI®/ImageJ® might be used to provide less subjective estimates of the percentage of a region of interest affected by IGD. Application of this technique may enable more accurate comparison of datasets between researchers.
Collapse
Affiliation(s)
| | - Justyna J Miszkiewicz
- School of Archaeology and Anthropology, Australian National University, College of Arts and Sciences, Canberra, Australia
| | - Carolina Loch
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Monica Tromp
- Department of Anatomy, University of Otago, Dunedin, New Zealand.,Southern Pacific Archaeological Research, Archaeology Programme, School of Social Sciences, University of Otago, Dunedin, New Zealand
| | - Hallie R Buckley
- Department of Anatomy, University of Otago, Dunedin, New Zealand
| |
Collapse
|
34
|
Seo SJ, Kim YG. Visualization of woven bone structure through analysis of biopsy specimens using synchrotron radiation and conventional X-ray microcomputed tomography. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:199-206. [PMID: 31868752 DOI: 10.1107/s1600577519015182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Accepted: 11/11/2019] [Indexed: 06/10/2023]
Abstract
This study explores the application of synchrotron radiation and conventional microcomputed tomography (SR-µCT and C-µCT, respectively) in evaluating bone-biopsy specimens. Bone-biopsy specimens were obtained using a trephine bur during bone-graft removal for implant placement six months after performing a maxillary sinus bone-graft procedure. Image data of specimens were obtained using SR-µCT and C-µCT. SR-µCT was performed using the 6C biomedical imaging beamline at the Pohang Accelerator Laboratory with a monochromatic X-ray beam of 23 keV, and C-µCT was performed using a table-top CT scanner (Skyscan 1272). Reconstruction images obtained using the two methods were qualitatively compared with 2D images evaluated under 3D visualization. The SR-µCT images, especially of the new-bone-graft-woven-bone formation, were less noisy and sharper than the C-µCT images. To evaluate the new-bone-graft-woven-bone formation, only the SR-µCT images showed areas of new bone (NB) formation with bone substitute (BS; Bio-Oss) and woven bone (WB) contact, and correctly visualized true 3D structures of bone formation. Hence, µCT techniques are non-destructive and can provide detailed images of bone biopsy. In particular, SR-µCT can be used to obtain improved image quality with contrast of NB, BS and WB, demonstrating a level of detail comparable with bone formation. SR-µCT could be an unbiased 3D alternative for imaging WB formation and for high-throughput analysis.
Collapse
Affiliation(s)
- Seung Jun Seo
- Department of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41940, Republic of Korea
| | - Yong Gun Kim
- Department of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41940, Republic of Korea
| |
Collapse
|
35
|
Clark JN, Garbout A, Ferreira SA, Javaheri B, Pitsillides AA, Rankin SM, Jeffers JRT, Hansen U. Propagation phase-contrast micro-computed tomography allows laboratory-based three-dimensional imaging of articular cartilage down to the cellular level. Osteoarthritis Cartilage 2020; 28:102-111. [PMID: 31678663 DOI: 10.1016/j.joca.2019.10.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 08/31/2019] [Accepted: 10/03/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE High-resolution non-invasive three-dimensional (3D) imaging of chondrocytes in articular cartilage remains elusive. The aim of this study was to explore whether laboratory micro-computed tomography (micro-CT) permits imaging cells within articular cartilage. DESIGN Bovine osteochondral plugs were prepared four ways: in phosphate-buffered saline (PBS) or 70% ethanol (EtOH), both with or without phosphotungstic acid (PTA) staining. Specimens were imaged with micro-CT following two protocols: 1) absorption contrast (AC) imaging 2) propagation phase-contrast (PPC) imaging. All samples were scanned in liquid. The contrast to noise ratio (C/N) of cellular features quantified scan quality and were statistically analysed. Cellular features resolved by micro-CT were validated by standard histology. RESULTS The highest quality images were obtained using propagation phase-contrast imaging and PTA-staining in 70% EtOH. Cellular features were also visualised when stained in PBS and unstained in EtOH. Under all conditions PPC resulted in greater contrast than AC (p < 0.0001 to p = 0.038). Simultaneous imaging of cartilage and subchondral bone did not impede image quality. Corresponding features were located in both histology and micro-CT and followed the same distribution with similar density and roundness values. CONCLUSIONS Three-dimensional visualisation and quantification of the chondrocyte population within articular cartilage can be achieved across a field of view of several millimetres using laboratory-based micro-CT. The ability to map chondrocytes in 3D opens possibilities for research in fields from skeletal development through to medical device design and treatment of cartilage degeneration.
Collapse
Affiliation(s)
- J N Clark
- Department of Mechanical Engineering, Imperial College London, London, UK.
| | - A Garbout
- Imaging and Analysis Centre, Natural History Museum London, London, UK.
| | - S A Ferreira
- National Heart & Lung Institute, Faculty of Medicine, Imperial College London, London, UK.
| | - B Javaheri
- Skeletal Biology Group, Comparative Biomedical Sciences, Royal Veterinary College, UK.
| | - A A Pitsillides
- Skeletal Biology Group, Comparative Biomedical Sciences, Royal Veterinary College, UK.
| | - S M Rankin
- National Heart & Lung Institute, Faculty of Medicine, Imperial College London, London, UK.
| | - J R T Jeffers
- Department of Mechanical Engineering, Imperial College London, London, UK.
| | - U Hansen
- Department of Mechanical Engineering, Imperial College London, London, UK.
| |
Collapse
|
36
|
Aboulkhair NT, Simonelli M, Parry L, Ashcroft I, Tuck C, Hague R. 3D printing of Aluminium alloys: Additive Manufacturing of Aluminium alloys using selective laser melting. PROGRESS IN MATERIALS SCIENCE 2019; 106:100578. [PMID: 0 DOI: 10.1016/j.pmatsci.2019.100578] [Citation(s) in RCA: 120] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
37
|
Ito T. Effects of different segmentation methods on geometric morphometric data collection from primate skulls. Methods Ecol Evol 2019. [DOI: 10.1111/2041-210x.13274] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Tsuyoshi Ito
- Department of Evolution and Phylogeny, Primate Research Institute Kyoto University Inuyama Aichi Japan
| |
Collapse
|
38
|
Karbalaeisadegh Y, Yousefian O, Iori G, Raum K, Muller M. Acoustic diffusion constant of cortical bone: Numerical simulation study of the effect of pore size and pore density on multiple scattering. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1015. [PMID: 31472561 PMCID: PMC6687498 DOI: 10.1121/1.5121010] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2019] [Revised: 07/15/2019] [Accepted: 07/20/2019] [Indexed: 06/01/2023]
Abstract
While osteoporosis assessment has long focused on the characterization of trabecular bone, the cortical bone micro-structure also provides relevant information on bone strength. This numerical study takes advantage of ultrasound multiple scattering in cortical bone to investigate the effect of pore size and pore density on the acoustic diffusion constant. Finite-difference time-domain simulations were conducted in cortical microstructures that were derived from acoustic microscopy images of human proximal femur cross sections and modified by controlling the density (Ct.Po.Dn) ∈[5-25] pore/mm2 and size (Ct.Po.Dm) ∈[30-100] μm of the pores. Gaussian pulses were transmitted through the medium and the backscattered signals were recorded to obtain the backscattered intensity. The incoherent contribution of the backscattered intensity was extracted to give access to the diffusion constant D. At 8 MHz, significant differences in the diffusion constant were observed in media with different porous micro-architectures. The diffusion constant was monotonously influenced by either pore diameter or pore density. An increase in pore size and pore density resulted in a decrease in the diffusion constant (D =285.9Ct.Po.Dm-1.49, R2=0.989 , p=4.96×10-5,RMSE=0.06; D=6.91Ct.Po.Dn-1.01, R2=0.94, p=2.8×10-3 , RMSE=0.09), suggesting the potential of the proposed technique for the characterization of the cortical microarchitecture.
Collapse
Affiliation(s)
- Yasamin Karbalaeisadegh
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695-8212, USA
| | - Omid Yousefian
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695-8212, USA
| | - Gianluca Iori
- Center for Regenerative Therapies, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Kay Raum
- Center for Regenerative Therapies, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695-8212, USA
| |
Collapse
|
39
|
Fiedler IAK, Zeveleva S, Duarte A, Zhao X, Depalle B, Cardoso L, Jin S, Berteau JP. Microstructure, mineral and mechanical properties of teleost intermuscular bones. J Biomech 2019; 94:59-66. [PMID: 31427091 DOI: 10.1016/j.jbiomech.2019.07.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 06/12/2019] [Accepted: 07/09/2019] [Indexed: 12/12/2022]
Abstract
There is an increasing interest in understanding teleost bone biomechanics in several scientific communities, for instance as interesting biomaterials with specific structure-function relationships. Intermuscular bones of teleost fish have previously been described to play a role in the mechanical force transmission between muscle and bone, but their biomechanical properties are not yet fully described. Here, we have investigated intermuscular bones (IBs) of the North Atlantic Herring with regard to their structure and micro-architecture, mineral-related properties, and micro-mechanical tensile properties. A total of 115 IBs from 18 fish were investigated. One cohort of IBs, containing 20 bones from 2 smaller fish and 23 bones of 3 larger fish, was used for mechanical testing, wide-angle X-ray scattering, and scanning electron microscopy. Another cohort, containing 36 bones from 7 smaller fish and 36 bones from 6 larger fish, was used for microCT. Results show some astonishing properties of the IBs: (i) IBs present higher ductility, lower Young's modulus but similar strength and TMD (Tissue Mineral Density) compared to mammalian bone, and (ii) IBs from small fish were 49% higher in Young's modulus than fish bones from larger fish while their TMD was not statistically different and crystal length was 8% higher in large fish bones. Our results revealed that teleost IB presents a hybrid nature of soft and hard tissue that differs from other bone types, which might be associated with their evolution from mineralized tendons. This study provides new data regarding teleost fish bone biomechanical and micro-structural properties.
Collapse
Affiliation(s)
- I A K Fiedler
- Department of Physical Therapy, City University of New York - College of Staten Island, USA; Department of Osteology and Biomechanics, University Medical Center Hamburg Eppendorf, DE, Germany
| | - S Zeveleva
- Department of Physical Therapy, City University of New York - College of Staten Island, USA
| | - A Duarte
- Department of Physical Therapy, City University of New York - College of Staten Island, USA
| | - X Zhao
- Department of Chemistry, City University of New York - College of Staten Island, USA
| | - B Depalle
- Department of Materials, Imperial College London, UK
| | - L Cardoso
- Department of Biomedical Engineering, City University of New York - City College of New York, USA
| | - S Jin
- Department of Chemistry, City University of New York - College of Staten Island, USA
| | - J P Berteau
- Department of Physical Therapy, City University of New York - College of Staten Island, USA; New York Center for Biomedical Engineering, City University of New York - City College of New York, USA; Nanoscience Initiative, Advanced Science Research Center, City University of New York, USA.
| |
Collapse
|
40
|
Miszkiewicz JJ, Louys J, O'Connor S. Microanatomical Record of Cortical Bone Remodeling and High Vascularity in a Fossil Giant Rat Midshaft Femur. Anat Rec (Hoboken) 2019; 302:1934-1940. [DOI: 10.1002/ar.24224] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2018] [Revised: 04/16/2019] [Accepted: 04/24/2019] [Indexed: 12/16/2022]
Affiliation(s)
- Justyna J. Miszkiewicz
- School of Archaeology and Anthropology, College of Arts and Social Sciences Australian National University Canberra Australia
| | - Julien Louys
- Australian Research Centre for Human Evolution, Environmental Futures Research Institute Griffith University Brisbane Australia
| | - Sue O'Connor
- Archaeology and Natural History, College of Asia and the Pacific Australian National University Canberra Australia
| |
Collapse
|
41
|
Gatti V, Ghobryal B, Gelbs MJ, Gerber MB, Doty SB, Cardoso L, Fritton SP. Botox-induced muscle paralysis alters intracortical porosity and osteocyte lacunar density in skeletally mature rats. J Orthop Res 2019; 37:1153-1163. [PMID: 30839119 DOI: 10.1002/jor.24276] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 02/12/2019] [Indexed: 02/04/2023]
Abstract
Reduced mechanical loading can lead to disuse osteoporosis, resulting in bone fragility. Disuse models report macroscopic bone loss due to muscle inactivity and immobilization, yet only recently has there been quantification of the effects of disuse on the vascular pores and osteocyte network, which are believed to play an important role in mechanotransduction via interstitial fluid flow. The goal of this study was to perform a high-resolution analysis of the effects of muscle inactivity on intracortical porosity and osteocyte lacunar density in skeletally mature rats. Muscle paralysis was induced in 20-week-old female Sprague Dawley rats by injection of botulinum neurotoxin. Rats were injected in the right hindlimb muscles with either Botox (BTX, n = 8) or saline solution (CTRL, n = 8), with a third group used as baseline controls (n = 8). Four weeks after injection, Botox caused a ∼60% reduction in hindlimb muscle mass. High-resolution micro-CT analysis showed that Botox-induced muscle paralysis increased vascular canal porosity and reduced osteocyte lacunar density within the tibial metaphysis cortex. Cortical thickness and other areal properties were diminished in the proximal tibial metaphysis, whereas no differences were found in the mid-diaphysis. Within the BTX group, the injected limbs showed a lower cancellous bone volume fraction relative to the contralateral limb. These results indicate that diminished muscle activity alters the vascular canal porosity and osteocyte lacunar density in cortical bone, which could alter interstitial fluid flow, affecting molecular transport and the transmission of mechanical signals to osteocytes. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.
Collapse
Affiliation(s)
- Vittorio Gatti
- Department of Biomedical Engineering, The City College of New York, 160 Convent Avenue, New York, New York, 10031
| | - Bishoy Ghobryal
- Department of Biomedical Engineering, The City College of New York, 160 Convent Avenue, New York, New York, 10031
| | - Michelle J Gelbs
- Department of Biomedical Engineering, The City College of New York, 160 Convent Avenue, New York, New York, 10031
| | - Michael B Gerber
- Department of Biomedical Engineering, The City College of New York, 160 Convent Avenue, New York, New York, 10031
| | - Stephen B Doty
- Hospital for Special Surgery Research Institute, 515 East 71st Street, New York, New York
| | - Luis Cardoso
- Department of Biomedical Engineering, The City College of New York, 160 Convent Avenue, New York, New York, 10031
| | - Susannah P Fritton
- Department of Biomedical Engineering, The City College of New York, 160 Convent Avenue, New York, New York, 10031
| |
Collapse
|
42
|
Othman MIA, Abd-Elaziz EM. Effect of initial stress and Hall current on a magneto-thermoelastic porous medium with microtemperatures. INDIAN JOURNAL OF PHYSICS 2019; 93:475-485. [DOI: 10.1007/s12648-018-1313-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Accepted: 07/12/2018] [Indexed: 09/02/2023]
|
43
|
Mehadji B, Ahmed Y, Berteau JP. A novel approach for computing 3D mice distal femur properties using high-resolution micro-computed tomography scanning. Micron 2019; 121:1-7. [PMID: 30861471 DOI: 10.1016/j.micron.2019.02.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2018] [Revised: 02/21/2019] [Accepted: 02/21/2019] [Indexed: 12/31/2022]
Abstract
One of the most-scanned joints in preclinical animal models dealing with musculoskeletal pathologies is the mouse knee. While three-dimensional (3D) characterization of bone tissue porosity have previously been performed on cortical bone, it has not yet been comprehensively performed for the subchondral bone (SB) and the calcified cartilage (CC), which compose the subchondral mineralized zone (SMZ). Thus, it remains challenging to assess changes that occur in the SMZ of the mouse knee during pathologies such as osteoarthritis. One of the keys to addressing this challenge is to segment each layer to measure their morphologies, material properties, and porosity. Our study presents a novel approach for computing Tissue Mineral Density, 3D porosity, and the thickness of SB and CC in a mouse distal femur using High-Resolution Micro-Computed Tomography (HR-μCT). We have segmented the Vascular Porosity network, the osteocytes' lacunae of the SB, and the chondrocytes of the CC by using multi-thresholding and the percentage of chondrocytes porosity. Our results show a low intra- and inter-observer coefficient of variability. Regarding porosity and geometrical properties of both CC and SB, our results are within the range of the literature. Our approach opens new avenues for assessing porosity and vascular changes in the distal femur of preclinical animal models dealing with musculoskeletal pathologies such as osteoarthritis.
Collapse
Affiliation(s)
- Brahim Mehadji
- Department of Physical Therapy, City University of New York - College of Staten Island, USA
| | - Yoseph Ahmed
- Department of Physical Therapy, City University of New York - College of Staten Island, USA
| | - Jean-Philippe Berteau
- Department of Physical Therapy, City University of New York - College of Staten Island, USA; New York Centre for Biomedical Engineering, City University of New York - City College of New York, USA; Nanosciences Initiative, City University of New York - Advance Science Research Center, New York, USA.
| |
Collapse
|
44
|
Radakovich LB, Marolf AJ, Shannon JP, Pannone SC, Sherk VD, Santangelo KS. Development of a microcomputed tomography scoring system to characterize disease progression in the Hartley guinea pig model of spontaneous osteoarthritis. Connect Tissue Res 2018; 59:523-533. [PMID: 29226725 PMCID: PMC6207938 DOI: 10.1080/03008207.2017.1409218] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 10/18/2017] [Accepted: 11/09/2017] [Indexed: 02/06/2023]
Abstract
AIM There is potential discrepancy between human and laboratory animal studies of osteoarthritis (OA), as radiographic assessment is the hallmark of the former and histopathology the standard for the latter. This suggests a need to evaluate OA in animal models in a manner similar to that utilized in people. Our study aimed to develop a whole joint grading scheme for microcomputed tomography (microCT) images in Hartley guinea pigs, a strain that recapitulates joint changes highlighted in human spontaneous OA. MATERIALS AND METHODS Knees from animals aged 2, 3, 5, 9, and 15 months were evaluated via whole joint microCT and standard histologic scoring. Quantitative microCT parameters, such as bone volume/total volume were also collected. RESULTS Both whole joint microCT and histologic scores increased with advancing age and showed strong correlation (r = 0.89. p < 0.0001). Histologic scores, which focus on cartilage changes, increased progressively with age. Whole joint microCT scores, which characterize bony changes, followed a stepwise pattern: scores increased between 3 and 5 months of age, stayed consistent between 5 and 9 months, and worsened again between 9 and 15 months. CONCLUSIONS This work provides data that advocates the use of a whole joint microCT scoring system in guinea pig studies of OA, as it provides important information regarding bony changes that occur at a different rate than articular cartilage changes. This grading scheme, in conjunction with histology and quantitative microCT measurements, may enhance the translational value of this animal model as it pertains to human work.
Collapse
Affiliation(s)
- Lauren B Radakovich
- a Department of Microbiology, Immunology, Pathology , Colorado State University , Fort Collins, CO, USA
| | - Angela J Marolf
- b Department of Environmental and Radiological Health Sciences , Colorado State University , Fort Collins, CO, USA
| | - John P Shannon
- a Department of Microbiology, Immunology, Pathology , Colorado State University , Fort Collins, CO, USA
| | - Stephen C Pannone
- a Department of Microbiology, Immunology, Pathology , Colorado State University , Fort Collins, CO, USA
| | - Vanessa D Sherk
- c Center for Women's Health Research , UC Anschutz Medical Campus , Aurora, CO, USA
| | - Kelly S Santangelo
- a Department of Microbiology, Immunology, Pathology , Colorado State University , Fort Collins, CO, USA
| |
Collapse
|
45
|
Karbalaeisadegh Y, Yousefian O, Muller M. Influence of micro-structural parameters on apparent absorption coefficient in porous structures mimicking cortical bone. IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM : [PROCEEDINGS]. IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM 2018; 2018:10.1109/ultsym.2018.8579610. [PMID: 39092167 PMCID: PMC11293489 DOI: 10.1109/ultsym.2018.8579610] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/04/2024]
Abstract
Ultrasound wave propagation in porous media is associated with energy loss and attenuation. Attenuation is caused by both scattering and absorption, and is influenced by the microstructure as well as the operating frequency. In the present simulation study, we calculate the attenuation coefficient in porous structures mimicking cortical bone both in presence and absence of absorption to isolate the effects of scattering and absorption on the total attenuation. A parameter called apparent absorptionα a p p . a b s is defined as the difference between the total attenuationα total and the attenuation exclusively due to scatteringα scat .α total , α scat andα app.abs are estimated in porous structures with varying pore diameters ( ϕ ∈ [ 40, 120 ] μ m ) and pore densities ( ρ ∈ [ 5, 25 ] pore / m m 2 ) at 5MHz and 8MHz. Results show that both scattering and absorption contribute to the total attenuation. They also illustrate that, although absorption only occurs in the solid matrix, the apparent absorptionα a p p . a b s is a function of porosity, presumably due to the presence of multiple scattering. For large values of k ϕ , an increase in pore size or density does not lead to increase inα s c a t and only results in an increase of the total attenuation as a result of increase inα app.abs. . On the other hand, in low/intermediate scattering regimes ( k ϕ ≤ 1 ) , an increase in either pore size or pore density results in increase inα scat whileα app.abs remains constant.
Collapse
Affiliation(s)
- Yasamin Karbalaeisadegh
- Mechanical and Aerospace Engineering Department, North Carolina State University, Raleigh, NC 27695-8212, USA
| | - Omid Yousefian
- Mechanical and Aerospace Engineering Department, North Carolina State University, Raleigh, NC 27695-8212, USA
| | - Marie Muller
- Mechanical and Aerospace Engineering Department, North Carolina State University, Raleigh, NC 27695-8212, USA
| |
Collapse
|
46
|
Pratt IV, Cooper DML. The effect of growth rate on the three-dimensional orientation of vascular canals in the cortical bone of broiler chickens. J Anat 2018; 233:531-541. [PMID: 30022496 PMCID: PMC6131975 DOI: 10.1111/joa.12847] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/12/2018] [Indexed: 11/28/2022] Open
Abstract
Vascular canals in cortical bone during growth and development typically show an anisotropic pattern with canals falling into three main categories: circumferential, radial, and longitudinal. Two major hypotheses attempt to explain the preferred orientations in bone: that vascular canal orientation is optimized to resist a predominant strain direction from functional loading, or that it reflects growth requirements and velocity. We use a controlled growth experiment in broiler chickens to investigate the effect of growth rate on vascular canal orientation. Using feed restriction we set up a fast growing control group and a slow growing restricted group. We compared the microstructure in the humerus and the femur at 42 days of age using synchrotron micro‐computed tomography (micro‐CT), a three‐dimensional (3D) method that visualizes the full canal network. We measured the 3D orientation of each canal in the whole cross‐section of the bone cortex using a set of custom imagej scripts. Using these orientations we compute laminar, radial, and longitudinal indices that measure the proportion of circumferential, radial, and longitudinal canals, by unit of length, in the cortex. Following previous studies we hypothesized that vascular canal orientation is related to growth, with radial canals linked to a faster growth rate and related to functional loading through a high laminar index in flight bones which reflects torsional loading resulting from active flight. The control group had final body weights that were nearly twice the final weights of the restricted group and higher absolute growth rates. We found consistent patterns in the comparison between the humerus and the femur in both groups, with the humerus having higher laminar and longitudinal indices, and a lower radial index than the femur. The control group had higher radial indices and lower laminar and longitudinal indices in both the humerus and the femur than the restricted group. The higher radial indices in our control group point to a link between radial canals and faster growth, and between laminar canals and slower growth, while the higher laminar indices in the humerus point to a link between circumferential canals and torsional loading. Overall, our results indicate that the orientation of the cortical canal network in a bone is the consequence of a complex interaction between the growth rate of that bone and functional loading environment.
Collapse
Affiliation(s)
- Isaac V Pratt
- Department of Anatomy & Cell Biology, University of Saskatchewan, Saskatoon, SK, Canada
| | - David M L Cooper
- Department of Anatomy & Cell Biology, University of Saskatchewan, Saskatoon, SK, Canada
| |
Collapse
|
47
|
Sharma D, Larriera AI, Palacio-Mancheno PE, Gatti V, Fritton JC, Bromage TG, Cardoso L, Doty SB, Fritton SP. The effects of estrogen deficiency on cortical bone microporosity and mineralization. Bone 2018; 110:1-10. [PMID: 29357314 PMCID: PMC6377161 DOI: 10.1016/j.bone.2018.01.019] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 01/09/2018] [Accepted: 01/15/2018] [Indexed: 12/22/2022]
Abstract
Recent studies have demonstrated matrix-mineral alterations in bone tissue surrounding osteocytes in estrogen-deficient animals. While cortical bone porosity has been shown to be a contributor to the mechanical properties of bone tissue, little analysis has been done to investigate the effects of estrogen deficiency on bone's microporosities, including the vascular and osteocyte lacunar porosities. In this study we examined alterations in cortical bone microporosity, mineralization, and cancellous bone architecture due to estrogen deficiency in the ovariectomized rat model of postmenopausal osteoporosis. Twenty-week-old female Sprague-Dawley rats were subjected to either ovariectomy or sham surgery. Six weeks post-surgery tibiae were analyzed using high-resolution micro-CT, backscattered electron imaging, nanoindentation, and dynamic histomorphometry. Estrogen deficiency caused an increase in cortical bone vascular porosity, with enlarged vascular pores and little change in tissue mineral density in the proximal tibial metaphysis. Measurements of cancellous architecture corresponded to previous studies reporting a decrease in bone volume fraction, an increase in trabecular separation, and a decrease in trabecular number in the proximal tibia due to estrogen deficiency. Nanoindentation results showed no differences in matrix stiffness in osteocyte-rich areas of the proximal tibia of estrogen-deficient rats, and bone labeling and backscattered electron imaging showed no significant changes in mineralization around the vascular pores. The findings demonstrate local surface alterations of vascular pores due to estrogen deficiency. An increase in cortical vascular porosity may diminish bone strength as well as alter bone mechanotransduction via interstitial fluid flow, both of which could contribute to bone fragility during postmenopausal osteoporosis.
Collapse
Affiliation(s)
- Divya Sharma
- Department of Biomedical Engineering, The City College of New York, New York, NY 10031, United States
| | - Adriana I Larriera
- Department of Biomedical Engineering, The City College of New York, New York, NY 10031, United States
| | - Paolo E Palacio-Mancheno
- Department of Biomedical Engineering, The City College of New York, New York, NY 10031, United States
| | - Vittorio Gatti
- Department of Biomedical Engineering, The City College of New York, New York, NY 10031, United States
| | - J Christopher Fritton
- Department of Orthopaedics, New Jersey Medical School, Rutgers University, Newark, NJ 07103, United States
| | - Timothy G Bromage
- Department of Biomaterials, New York University College of Dentistry, New York, NY 10010, United States
| | - Luis Cardoso
- Department of Biomedical Engineering, The City College of New York, New York, NY 10031, United States
| | - Stephen B Doty
- Research Division, Hospital for Special Surgery, New York, NY 10021, United States
| | - Susannah P Fritton
- Department of Biomedical Engineering, The City College of New York, New York, NY 10031, United States.
| |
Collapse
|
48
|
PPARγ agonists promote differentiation of cancer stem cells by restraining YAP transcriptional activity. Oncotarget 2018; 7:60954-60970. [PMID: 27528232 PMCID: PMC5308629 DOI: 10.18632/oncotarget.11273] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Accepted: 08/01/2016] [Indexed: 12/22/2022] Open
Abstract
Osteosarcoma (OS) is a highly aggressive pediatric bone cancer in which most tumor cells remain immature and fail to differentiate into bone-forming osteoblasts. However, OS cells readily respond to adipogenic stimuli suggesting they retain mesenchymal stem cell-like properties. Here we demonstrate that nuclear receptor PPARγ agonists such as the anti-diabetic, thiazolidinedione (TZD) drugs induce growth arrest and cause adipogenic differentiation in human, mouse and canine OS cells as well as in tumors in mice. Gene expression analysis reveals that TZDs induce lipid metabolism pathways while suppressing targets of the Hippo-YAP pathway, Wnt signaling and cancer-related proliferation pathways. Significantly, TZD action appears to be restricted to the high Sox2 expressing cancer stem cell population and is dependent on PPARγ expression. TZDs also affect growth and cell fate by causing the cytoplasmic sequestration of the transcription factors SOX2 and YAP that are required for tumorigenicity. Finally, we identify a TZD-regulated gene signature based on Wnt/Hippo target genes and PPARγ that predicts patient outcomes. Together, this work highlights a novel connection between PPARγ agonist in inducing adipogenesis and mimicking the tumor suppressive hippo pathway. It also illustrates the potential of drug repurposing for TZD-based differentiation therapy for osteosarcoma.
Collapse
|
49
|
Computational Investigation on the Biomechanical Responses of the Osteocytes to the Compressive Stimulus: A Poroelastic Model. BIOMED RESEARCH INTERNATIONAL 2018; 2018:4071356. [PMID: 29581973 PMCID: PMC5822791 DOI: 10.1155/2018/4071356] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 12/02/2017] [Accepted: 12/19/2017] [Indexed: 11/17/2022]
Abstract
Osteocytes, the major type of bone cells embedded in the bone matrix and surrounded by the lacunar and canalicular system, can serve as biomechanosensors and biomechanotranducers of the bone. Theoretical analytical methods have been employed to investigate the biomechanical responses of osteocytes in vivo; the poroelastic properties have not been taken into consideration in the three-dimensional (3D) finite element model. In this study, a 3D poroelastic idealized finite element model was developed and was used to predict biomechanical behaviours (maximal principal strain, pore pressure, and fluid velocity) of the osteocyte-lacunar-canalicular system under 150-, 1000-, 3000-, and 5000-microstrain compressive loads, respectively, representing disuse, physiological, overuse, and pathological overload loading stimuli. The highest local strain, pore pressure, and fluid velocity were found to be highest at the proximal region of cell processes. These data suggest that the strain, pore pressure, and fluid velocity of the osteocyte-lacunar-canalicular system increase with the global loading and that the poroelastic material property affects the biomechanical responses to the compressive stimulus. This new model can be used to predict the mechanobiological behaviours of osteocytes under the four different compressive loadings and may provide an insight into the mechanisms of mechanosensation and mechanotransduction of the bone.
Collapse
|
50
|
Microstructural changes associated with osteoporosis negatively affect loading-induced fluid flow around osteocytes in cortical bone. J Biomech 2017; 66:127-136. [PMID: 29217091 DOI: 10.1016/j.jbiomech.2017.11.011] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Revised: 11/05/2017] [Accepted: 11/09/2017] [Indexed: 12/21/2022]
Abstract
Loading-induced interstitial fluid flow in the microporosities of bone is critical for osteocyte mechanotransduction and for the maintenance of tissue health, enhancing convective transport in the lacunar-canalicular system. In recent studies, our group has reported alterations of bone's vascular porosity and lacunar-canalicular system microarchitecture in a rat model of postmenopausal osteoporosis. In this work, poroelastic finite element analysis was used to investigate whether these microstructural changes can affect interstitial fluid flow around osteocytes. Animal-specific finite element models were developed combining micro-CT reconstructions of bone microstructure and measures of the poroelastic material properties. These models were used to quantify and compare loading-induced fluid flow in the lacunar-canalicular system of ovariectomized and sham-operated rats. A parametric analysis was also used to quantify the influence of the lacunar-canalicular permeability and vascular porosity on the fluid velocity magnitude. Results show that mechanically-induced interstitial fluid velocity can be significantly reduced in the lacunar-canalicular system of ovariectomized rats. Interestingly, the vascular porosity is shown to have a major influence on interstitial fluid flow, while the lacunar-canalicular permeability influence is limited when larger than 10-20m2. Altogether our results suggest that microstructural changes associated with the osteoporotic condition can negatively affect interstitial fluid flow around osteocytes in the lacunar-canalicular system of cortical bone. This fluid flow reduction could impair mechanosensation of the osteocytic network, possibly playing a role in the initiation and progression of age-related bone loss and postmenopausal osteoporosis.
Collapse
|