1
|
Schwerdt G, Schulz MC, Kopf M, Mildenberger S, Reime S, Gekle M. Physiological regulation of oral saliva ion composition and flow rate are not coupled in healthy humans-Partial revision of our current knowledge required. Pflugers Arch 2024:10.1007/s00424-024-03025-9. [PMID: 39354192 DOI: 10.1007/s00424-024-03025-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 09/24/2024] [Accepted: 09/24/2024] [Indexed: 10/03/2024]
Abstract
Appropriate composition of oral saliva is essential for a healthy milieu that protects mucosa and teeth. Only few studies, with small sample numbers, investigated physiological saliva ion composition in humans. We determined saliva ion composition in a sufficiently large cohort of healthy adults and analyzed the effect of physiological stimulation. We collected saliva from 102 adults under non-stimulated and physiologically stimulated conditions (chewing). Individual flow rates, pH, osmolality, Na+, K+, Cl-, and HCO3- concentrations under both conditions as well as the individual changes due to stimulation (Δvalues) were determined. Non-stimulated saliva was hypoosmolal and acidic. Na+, Cl-, and HCO3- concentrations remained well below physiological plasma values, whereas K+ concentrations exceeded plasma values more than twofold. Stimulation resulted in a doubling of flow rates and substantial increases in pH, HCO3-, and Na+ concentrations. Overall, stimulation did not considerably affect osmolality nor K+ or Cl- concentrations of saliva. An in-depth analysis of stimulation effects, using individual Δvalues, showed no correlation of Δflow rate with Δion concentrations, indicating independent regulation of acinar volume and ductal ion transport. Stimulation-induced Δ[Na+] correlated with Δ[HCO3-] and Δ[Cl-] but not with Δ[K+], indicating common regulation of ductal Na+, Cl-, and HCO3- transport. We present a robust data set of human oral saliva ion composition in healthy adults and functional insights into physiological stimulation. Our data show (i) that flow-dependence exists for Na+ and HCO3- but not for K+ and Cl- concentrations, (ii) osmolality is flow-independent, (iii) regulation of Na+, Cl-, and HCO3- transport is coupled, (iv) regulation of flow rate and ion concentrations are independent and (v) spatially separated between acini and ducts, respectively.
Collapse
Affiliation(s)
- Gerald Schwerdt
- Julius-Bernstein-Institute of Physiology, Martin-Luther-Universität Halle-Wittenberg, Magdeburger Straße 6, 06112, Halle (Saale), Germany
| | - Marie-Christin Schulz
- Julius-Bernstein-Institute of Physiology, Martin-Luther-Universität Halle-Wittenberg, Magdeburger Straße 6, 06112, Halle (Saale), Germany
| | - Michael Kopf
- Julius-Bernstein-Institute of Physiology, Martin-Luther-Universität Halle-Wittenberg, Magdeburger Straße 6, 06112, Halle (Saale), Germany
| | - Sigrid Mildenberger
- Julius-Bernstein-Institute of Physiology, Martin-Luther-Universität Halle-Wittenberg, Magdeburger Straße 6, 06112, Halle (Saale), Germany
| | - Sarah Reime
- Julius-Bernstein-Institute of Physiology, Martin-Luther-Universität Halle-Wittenberg, Magdeburger Straße 6, 06112, Halle (Saale), Germany
| | - Michael Gekle
- Julius-Bernstein-Institute of Physiology, Martin-Luther-Universität Halle-Wittenberg, Magdeburger Straße 6, 06112, Halle (Saale), Germany.
| |
Collapse
|
2
|
Kim KR, Kang TW, Kim H, Lee YJ, Lee SH, Yi H, Kim HS, Kim H, Min J, Ready J, Millard-Stafford M, Yeo WH. All-in-One, Wireless, Multi-Sensor Integrated Athlete Health Monitor for Real-Time Continuous Detection of Dehydration and Physiological Stress. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2403238. [PMID: 38950170 PMCID: PMC11434103 DOI: 10.1002/advs.202403238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 06/03/2024] [Indexed: 07/03/2024]
Abstract
Athletes are at high risk of dehydration, fatigue, and cardiac disorders due to extreme performance in often harsh environments. Despite advancements in sports training protocols, there is an urgent need for a non-invasive system capable of comprehensive health monitoring. Although a few existing wearables measure athlete's performance, they are limited by a single function, rigidity, bulkiness, and required straps and adhesives. Here, an all-in-one, multi-sensor integrated wearable system utilizing a set of nanomembrane soft sensors and electronics, enabling wireless, real-time, continuous monitoring of saliva osmolality, skin temperature, and heart functions is introduced. This system, using a soft patch and a sensor-integrated mouthguard, provides comprehensive monitoring of an athlete's hydration and physiological stress levels. A validation study in detecting real-time physiological levels shows the device's performance in capturing moments (400-500 s) of synchronized acute elevation in dehydration (350%) and physiological strain (175%) during field training sessions. Demonstration with a few human subjects highlights the system's capability to detect early signs of health abnormality, thus improving the healthcare of sports athletes.
Collapse
Affiliation(s)
- Ka Ram Kim
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Tae Woog Kang
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Hodam Kim
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Yoon Jae Lee
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Sung Hoon Lee
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Hoon Yi
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Hyeon Seok Kim
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Hojoong Kim
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Jihee Min
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Department of Biology, College of Arts and Sciences, Emory University, Atlanta, GA, 30322, USA
| | - Jud Ready
- Electro-Optical Systems Laboratory, Georgia Tech Research Institute, Atlanta, GA, 30332, USA
| | | | - Woon-Hong Yeo
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Wearable Intelligent Systems and Healthcare Center (WISH Center), Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Tech and Emory University School of Medicine, Atlanta, GA, 30332, USA
- Parker H. Petit Institute for Bioengineering and Biosciences, Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| |
Collapse
|
3
|
Gray M, Birkenfeld JS, Butterworth I. Noninvasive Monitoring to Detect Dehydration: Are We There Yet? Annu Rev Biomed Eng 2023; 25:23-49. [PMID: 36854261 DOI: 10.1146/annurev-bioeng-062117-121028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
Abstract
The need for hydration monitoring is significant, especially for the very young and elderly populations who are more vulnerable to becoming dehydrated and suffering from the effects that dehydration brings. This need has been among the drivers of considerable effort in the academic and commercial sectors to provide a means for monitoring hydration status, with a special interest in doing so outside the hospital or clinical setting. This review of emerging technologies provides an overview of many technology approaches that, on a theoretical basis, have sensitivity to water and are feasible as a routine measurement. We review the evidence of technical validation and of their use in humans. Finally, we highlight the essential need for these technologies to be rigorously evaluated for their diagnostic potential, as a necessary step to meet the need for hydration monitoring outside of the clinical environment.
Collapse
Affiliation(s)
- Martha Gray
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA;
- MIT linQ, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Judith S Birkenfeld
- MIT linQ, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
- Instituto de Óptica "Daza de Valdés," Consejo Superior de Investigaciones Científicas, Madrid, Spain;
| | - Ian Butterworth
- MIT linQ, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
- Leuko Labs Inc., Boston, Massachusetts, USA
| |
Collapse
|
4
|
Buijk MS, Dijkshoorn M, Dwarkasing RS, Chorley AC, Minnee RC, Boehnert MU. Accuracy of preoperative liver volumetry in living donor liver transplantation—A systematic review and meta-analysis. JOURNAL OF LIVER TRANSPLANTATION 2023. [DOI: 10.1016/j.liver.2023.100150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/03/2023] Open
|
5
|
Effect of Glycerol-Induced Hyperhydration on a 5-kilometer Running Time-Trial Performance in the Heat in Recreationally Active Individuals. Nutrients 2023; 15:nu15030599. [PMID: 36771308 PMCID: PMC9919238 DOI: 10.3390/nu15030599] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/18/2023] [Accepted: 01/20/2023] [Indexed: 01/26/2023] Open
Abstract
Maximal oxygen consumption (V˙O2max) is a major determinant of 5-km running time-trial (TT) performance. Glycerol-induced hyperhydration (GIH) could improve V˙O2max in recreationally active persons through an optimal increase in plasma volume. Moreover, ingestion of a large bolus of cold fluid before exercise could decrease thermal stress during exercise, potentially contributing to improved performance. We determined the effect of GIH on 5-km running TT performance in 10 recreationally active individuals (age: 24 ± 4 years; V˙O2max: 48 ± 3 mL/kg/min). Using a randomized and counterbalanced protocol, participants underwent two, 120-min hydration protocols where they ingested a 1) 30 mL/kg fat-free mass (FFM) of cold water (~4 °C) with an artificial sweetener + 1.4 g glycerol/kg FFM over the first 60 min (GIH) or 2) 7.5 mL/kg FFM of cold water with an artificial sweetener over the first 20 min (EUH). Following GIH and EUH, participants underwent a 5-km running TT at 30 °C and 50% relative humidity. After 120 min, GIH was associated with significantly greater fluid retention (846 ± 415 mL) and plasma volume changes (10.1 ± 8.4%) than EUH, but gastrointestinal (GI) temperature did not differ. During exercise, 5-km running TT performance (GIH: 22.95 ± 2.62; EUH: 22.52 ± 2.74 min), as well as heart rate, GI temperature and perceived exertion did not significantly differ between conditions. This study demonstrates that the additional body water and plasma volume gains provided by GIH do not improve 5-km running TT performance in the heat in recreationally active individuals.
Collapse
|
6
|
Pskowski A, Bagchi P, Zahn JD. Hematocrit skewness along sequential bifurcations within a microfluidic network induces significant changes in downstream red blood cell partitioning. BIOMICROFLUIDICS 2022; 16:064104. [PMID: 36483019 PMCID: PMC9726222 DOI: 10.1063/5.0110235] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 11/15/2022] [Indexed: 06/17/2023]
Abstract
There has been a wealth of research conducted regarding the partitioning of red blood cells (RBCs) at bifurcations within the microvasculature. In previous studies, partitioning has been characterized as either regular partitioning, in which the higher flow rate daughter channel receives a proportionally larger percentage of RBCs, or reverse partitioning, in which the opposite occurs. While there are many examples of network studies in silico, most in vitro work has been conducted using single bifurcation. When microfluidic networks have been used, the channel dimensions are typically greater than 20 μm, ignoring conditions where RBCs are highly confined. This paper presents a study of RBC partitioning in a network of sequential bifurcations with channel dimensions less than 8 μm in hydraulic diameter. The study investigated the effect of the volumetric flow rate ratio (Q*) at each bifurcation, solution hematocrit, and channel length on the erythrocyte flux ratio (N*), a measure of RBC partitioning. We report significant differences in partitioning between upstream and downstream bifurcations even when the flow rate ratio remains the same. Skewness analysis, a measure of cell distribution across the width of a vessel, strongly suggests that immediately following the first bifurcation most RBCs are skewed toward the inner channel wall, leading to preferential RBC perfusion into one daughter channel at the subsequent bifurcation even at higher downstream flow rate ratios. The skewness of RBC distribution following the first bifurcation can either manifest as enhanced regular partitioning or reverse partitioning at the succeeding branch.
Collapse
Affiliation(s)
- Andrew Pskowski
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey 08854, USA
| | - Prosenjit Bagchi
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey 08854, USA
| | - Jeffrey D. Zahn
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, New Jersey 08854, USA
| |
Collapse
|
7
|
Interspecies Diversity of Osmotic Gradient Deformability of Red Blood Cells in Human and Seven Vertebrate Animal Species. Cells 2022; 11:cells11081351. [PMID: 35456029 PMCID: PMC9026962 DOI: 10.3390/cells11081351] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 04/07/2022] [Accepted: 04/13/2022] [Indexed: 11/24/2022] Open
Abstract
Plasma and blood osmolality values show interspecies differences and are strictly regulated. The effect of these factors also has an influence on microrheological parameters, such as red blood cell (RBC) deformability and aggregation. However, little is known about the interspecies differences in RBC deformability at various blood osmolality levels (osmotic gradient RBC deformability). Our aim was to conduct a descriptive–comparative study on RBC osmotic gradient deformability in several vertebrate species and human blood. Blood samples were taken from healthy volunteers, dogs, cats, pigs, sheep, rabbits, rats, and mice, to measure hematological parameters, as well as conventional and osmotic gradient RBC deformability. Analyzing the elongation index (EI)–osmolality curves, we found the highest maximal EI values (EI max) in human, dog, and rabbit samples. The lowest EI max values were seen in sheep and cat samples, in addition to a characteristic leftward shift of the elongation index–osmolality curves. We found significant differences in the hyperosmolar region. A correlation of mean corpuscular volume and mean corpuscular hemoglobin concentration with osmoscan parameters was found. Osmotic gradient deformability provides further information for better exploration of microrheological diversity between species and may help to better understand the alterations caused by osmolality changes in various disorders.
Collapse
|
8
|
Murray A, Congdon TR, Tomás RMF, Kilbride P, Gibson MI. Red Blood Cell Cryopreservation with Minimal Post-Thaw Lysis Enabled by a Synergistic Combination of a Cryoprotecting Polyampholyte with DMSO/Trehalose. Biomacromolecules 2022; 23:467-477. [PMID: 34097399 PMCID: PMC7612374 DOI: 10.1021/acs.biomac.1c00599] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 05/24/2021] [Indexed: 12/16/2022]
Abstract
From trauma wards to chemotherapy, red blood cells are essential in modern medicine. Current methods to bank red blood cells typically use glycerol (40 wt %) as a cryoprotective agent. Although highly effective, the deglycerolization process, post-thaw, is time-consuming and results in some loss of red blood cells during the washing procedures. Here, we demonstrate that a polyampholyte, a macromolecular cryoprotectant, synergistically enhances ovine red blood cell cryopreservation in a mixed cryoprotectant system. Screening of DMSO and trehalose mixtures identified optimized conditions, where cytotoxicity was minimized but cryoprotective benefit maximized. Supplementation with polyampholyte allowed 97% post-thaw recovery (3% hemolysis), even under extremely challenging slow-freezing and -thawing conditions. Post-thaw washing of the cryoprotectants was tolerated by the cells, which is crucial for any application, and the optimized mixture could be applied directly to cells, causing no hemolysis after 1 h of exposure. The procedure was also scaled to use blood bags, showing utility on a scale relevant for application. Flow cytometry and adenosine triphosphate assays confirmed the integrity of the blood cells post-thaw. Microscopy confirmed intact red blood cells were recovered but with some shrinkage, suggesting that optimization of post-thaw washing could further improve this method. These results show that macromolecular cryoprotectants can provide synergistic benefit, alongside small molecule cryoprotectants, for the storage of essential cell types, as well as potential practical benefits in terms of processing/handling.
Collapse
Affiliation(s)
- Alex Murray
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, U.K.
| | - Thomas R. Congdon
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, U.K.
| | - Ruben M. F. Tomás
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, U.K.
- Warwick
Medical School, University of Warwick, Coventry CV4 7AL, U.K.
| | - Peter Kilbride
- Asymptote, Cytiva, Chivers Way, Cambridge CB24 9BZ, U.K.
| | - Matthew I. Gibson
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, U.K.
- Warwick
Medical School, University of Warwick, Coventry CV4 7AL, U.K.
| |
Collapse
|
9
|
Britto DT, Coskun D, Kronzucker HJ. Potassium physiology from Archean to Holocene: A higher-plant perspective. JOURNAL OF PLANT PHYSIOLOGY 2021; 262:153432. [PMID: 34034042 DOI: 10.1016/j.jplph.2021.153432] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 04/22/2021] [Accepted: 04/22/2021] [Indexed: 05/27/2023]
Abstract
In this paper, we discuss biological potassium acquisition and utilization processes over an evolutionary timescale, with emphasis on modern vascular plants. The quintessential osmotic and electrical functions of the K+ ion are shown to be intimately tied to K+-transport systems and membrane energization. Several prominent themes in plant K+-transport physiology are explored in greater detail, including: (1) channel mediated K+ acquisition by roots at low external [K+]; (2) K+ loading of root xylem elements by active transport; (3) variations on the theme of K+ efflux from root cells to the extracellular environment; (4) the veracity and utility of the "affinity" concept in relation to transport systems. We close with a discussion of the importance of plant-potassium relations to our human world, and current trends in potassium nutrition from farm to table.
Collapse
Affiliation(s)
- Dev T Britto
- Faculty of Land and Food Systems, University of British Columbia, Vancouver, BC, V6T 1Z4, Canada; School of BioSciences, The University of Melbourne, Parkville, Victoria, 3010, Australia
| | - Devrim Coskun
- Département de Phytologie, Faculté des Sciences de l'Agriculture et de l'Alimentation (FSAA), Université Laval, Québec, QC, G1V 0A6, Canada
| | - Herbert J Kronzucker
- Faculty of Land and Food Systems, University of British Columbia, Vancouver, BC, V6T 1Z4, Canada; School of BioSciences, The University of Melbourne, Parkville, Victoria, 3010, Australia.
| |
Collapse
|
10
|
Pskowski A, Bagchi P, Zahn JD. Investigation of red blood cell partitioning in an in vitro microvascular bifurcation. Artif Organs 2021; 45:1083-1096. [PMID: 33590890 DOI: 10.1111/aor.13941] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 01/29/2021] [Accepted: 02/09/2021] [Indexed: 01/12/2023]
Abstract
There is a long history of research examining red blood cell (RBC) partitioning in microvasculature bifurcations. These studies commonly report results describing partitioning that exists as either regular partitioning, which occurs when the RBC flux ratio is greater than the bulk fluid flowrate ratio, or reverse partitioning when the RBC flux ratio is less than or equal to that of the bulk fluid flowrate. This paper presents a study of RBC partitioning in a single bifurcating microchannel with dimensions of 6 to 16 μm, investigating the effects of hematocrit, channel width, daughter channel flowrate ratio, and bifurcation angle. The erythrocyte flux ratio, N*, manifests itself as either regular or reverse partitioning, and time-dependent partitioning is much more dynamic, occurring as both regular and reverse partitioning. We report a significant reduction in the well-known sigmoidal variation of the erythrocyte flux ratio (N*) versus the volumetric flowrate ratio (Q*), partitioning behavior with increasing hematocrit in microchannels when the channel dimensions are comparable with cell size. RBCs "lingering" or jamming at the bifurcation were also observed and quantified in vitro. Results from trajectory analyses suggest that the RBC position in the feeder channel strongly affects both partitioning and lingering frequency of RBCs, with both being significantly reduced when RBCs flow on streamlines near the edge of the channel as opposed to the center of the channel. Furthermore, our experiments suggest that even at low Reynolds number, partitioning is affected by the bifurcation angle by increasing cell-cell interactions. The presented results provide further insight into RBC partitioning as well as perfusion throughout the microvasculature.
Collapse
Affiliation(s)
- Andrew Pskowski
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ, USA
| | - Prosenjit Bagchi
- Department of Mechanical and Aerospace Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ, USA
| | - Jeffrey D Zahn
- Department of Biomedical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ, USA
| |
Collapse
|
11
|
Wang Y, Gao Z, Han Z, Liu Y, Yang H, Akkin T, Hogan CJ, Bischof JC. Aggregation affects optical properties and photothermal heating of gold nanospheres. Sci Rep 2021; 11:898. [PMID: 33441620 PMCID: PMC7806971 DOI: 10.1038/s41598-020-79393-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 12/03/2020] [Indexed: 01/29/2023] Open
Abstract
Laser heating of gold nanospheres (GNS) is increasingly prevalent in biomedical applications due to tunable optical properties that determine heating efficiency. Although many geometric parameters (i.e. size, morphology) can affect optical properties of individual GNS and their heating, no specific studies of how GNS aggregation affects heating have been carried out. We posit here that aggregation, which can occur within some biological systems, will significantly impact the optical and therefore heating properties of GNS. To address this, we employed discrete dipole approximation (DDA) simulations, Ultraviolet-Visible spectroscopy (UV-Vis) and laser calorimetry on GNS primary particles with diameters (5, 16, 30 nm) and their aggregates that contain 2 to 30 GNS particles. DDA shows that aggregation can reduce the extinction cross-section on a per particle basis by 17-28%. Experimental measurement by UV-Vis and laser calorimetry on aggregates also show up to a 25% reduction in extinction coefficient and significantly lower heating (~ 10%) compared to dispersed GNS. In addition, comparison of select aggregates shows even larger extinction cross section drops in sparse vs. dense aggregates. This work shows that GNS aggregation can change optical properties and reduce heating and provides a new framework for exploring this effect during laser heating of nanomaterial solutions.
Collapse
Affiliation(s)
- Yiru Wang
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA
| | - Zhe Gao
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA
| | - Zonghu Han
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA
| | - Yilin Liu
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA
| | - Huan Yang
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA
| | - Taner Akkin
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA
| | - Christopher J Hogan
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA
| | - John C Bischof
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA.
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN, 55455, USA.
| |
Collapse
|
12
|
de Hoop H, Petterson NJ, van de Vosse FN, van Sambeek MRHM, Schwab HM, Lopata RGP. Multiperspective Ultrasound Strain Imaging of the Abdominal Aorta. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:3714-3724. [PMID: 32746118 DOI: 10.1109/tmi.2020.3003430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Current decision-making for clinical intervention of abdominal aortic aneurysms (AAAs) is based on the maximum diameter of the aortic wall, but this does not provide patient-specific information on rupture risk. Ultrasound (US) imaging can assess both geometry and deformation of the aortic wall. However, low lateral contrast and resolution are currently limiting the precision of both geometry and local strain estimates. To tackle these drawbacks, a multiperspective scanning mode was developed on a dual transducer US system to perform strain imaging at high frame rates. Experimental imaging was performed on porcine aortas embedded in a phantom of the abdomen, pressurized in a mock circulation loop. US images were acquired with three acquisition schemes: Multiperspective ultrafast imaging, single perspective ultrafast imaging, and conventional line-by-line scanning. Image registration was performed by automatic detection of the transducer surfaces. Multiperspective images and axial displacements were compounded for improved segmentation and tracking of the aortic wall, respectively. Performance was compared in terms of image quality, motion tracking, and strain estimation. Multiperspective compound displacement estimation reduced the mean motion tracking error over one cardiac cycle by a factor 10 compared to conventional scanning. Resolution increased in radial and circumferential strain images, and circumferential signal-to-noise ratio (SNRe) increased by 10 dB. Radial SNRe is high in wall regions moving towards the transducer. In other regions, radial strain estimates remain cumbersome for the frequency used. In conclusion, multiperspective US imaging was demonstrated to improve motion tracking and circumferential strain estimation of porcine aortas in an experimental set-up.
Collapse
|
13
|
Abstract
BACKGROUND The temporality between the mandated reduction of salt in processed food and the decrease of death from stroke and ischemic heart disease, the association of hypertension, and cardiovascular disease led many public health organizations to recommend reducing dietary sodium to a maximum of 2300 mg per day. It turns out that some nuances can be brought about to this universally shared belief. METHODS & RESULTS Indeed, consideration of health outcomes instead of only blood pressure as a surrogate marker of cardiovascular disease and prognosis gave contradictory results whereas low sodium intake is associated to an excess of death and cardiovascular events. CONCLUSIONS Accordingly, sodium intake should be adapted to individual risk factors, and evidence is still clearly lacking to support indiscriminate recommendations in healthy people. By contrast, a restricted sodium diet is certainly useful in patients with chronic kidney disease exposed to salt retention, and by reciprocity, low sodium diet must be absolutely avoided in all patients presenting renal or extra renal sodium wasting where sodium depletion is a life-threatening condition.
Collapse
Affiliation(s)
- Georges Deschênes
- Department of Pediatric Nephrology, APHP Robert-Debré, University of Paris, APHP Robert-Debré, 48 Bd Sérurier, 75019, Paris, France.
| |
Collapse
|
14
|
Busmann EF, Martínez DG, Lucas H, Mäder K. Phase inversion-based nanoemulsions of medium chain triglyceride as potential drug delivery system for parenteral applications. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2020; 11:213-224. [PMID: 32082961 PMCID: PMC7006485 DOI: 10.3762/bjnano.11.16] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Accepted: 12/05/2019] [Indexed: 06/10/2023]
Abstract
Lipid nanoemulsions are attractive drug delivery systems for lipophilic drugs. To produce nanoemulsions with droplets of very small diameter (<100 nm), we investigated thermotropic phase transitions as an alternative to the standard procedure of high-pressure homogenization. Employing shock dilution with ice-cold water during the phase inversion gives the opportunity to produce nanoemulsions without any use of potentially toxic organic solvents. The systematic investigation of the relation of the three involved components surfactant, aqueous phase and lipid phase showed that depending on the ratio of surfactant to lipid the emulsions contained particles of diameters between 16 and 175 nm with narrow polydispersity index distributions and uncharged surfaces. Nanoemulsions with particles of 50 and 100 nm in diameter showed very little toxicity to fibroblast cells in vitro. An unusual, exponential-like nonlinear increase in osmolality was observed with increasing concentration of the nonionic surfactant Kolliphor HS 15. The experimental results indicate, that nanoemulsions with particles of small and tunable size can be easily formed without homogenization by thermal cycling.
Collapse
Affiliation(s)
- Eike Folker Busmann
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
| | - Dailén García Martínez
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
| | - Henrike Lucas
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
| | - Karsten Mäder
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Halle (Saale), Germany
| |
Collapse
|
15
|
Sollanek KJ, Kenefick RW, Cheuvront SN. Osmolality of Commercially Available Oral Rehydration Solutions: Impact of Brand, Storage Time, and Temperature. Nutrients 2019; 11:nu11071485. [PMID: 31261904 PMCID: PMC6682936 DOI: 10.3390/nu11071485] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2019] [Revised: 06/26/2019] [Accepted: 06/27/2019] [Indexed: 11/16/2022] Open
Abstract
Oral rehydration solutions (ORS) are specifically formulated with an osmolality to optimize fluid absorption. However, it is unclear how many ORS products comply with current World Health Organization (WHO) osmolality guidelines and the osmotic shelf-life stability is not known. Therefore, the purpose of this investigation was to examine the within and between ORS product osmolality variation in both pre-mixed and reconstituted powders. Additionally, the osmotic stability was examined over time. The osmolality of five different pre-mixed solutions and six powdered ORS products were measured. Pre-mixed solutions were stored at room temperatures and elevated temperatures (31 °C) for two months to examine osmotic shelf stability. Results demonstrated that only one pre-mixed ORS product was in compliance with the current guidelines both before and after the prolonged storage. Five of the six powdered ORS products were in compliance with minimal inter-packet variation observed within the given formulations. This investigation demonstrates that many commercially available pre-mixed ORS products do not currently adhere to the WHO recommended osmolality guidelines. Additionally, due to the presence of particular sugars and possibly other ingredients, the shelf-life stability of osmolality for certain ORS products may be questioned. These findings should be carefully considered in the design of future ORS products.
Collapse
Affiliation(s)
- Kurt J Sollanek
- Department of Kinesiology, Sonoma State University, Rohnert Park, CA 94928, USA.
| | | | | |
Collapse
|
16
|
Sollanek KJ, Kenefick RW, Cheuvront SN. Importance of sample volume to the measurement and interpretation of plasma osmolality. J Clin Lab Anal 2018; 33:e22727. [PMID: 30474168 PMCID: PMC6818608 DOI: 10.1002/jcla.22727] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Revised: 10/31/2018] [Accepted: 10/31/2018] [Indexed: 11/12/2022] Open
Abstract
Background Small sample volumes may artificially elevate plasma osmolality (Posm) measured by freezing point depression. The purpose of this study was to compare two widely different sample volumes of measured Posm (mmol/kg) to each other, and to calculated osmolarity (mmol/L), across a physiological Posm range (~50 mmol/kg). Methods Posm was measured using freezing point depression and osmolarity calculated from measures of sodium, glucose, and blood urea nitrogen. The influence of sample volume was investigated by comparing 20 and 250 μL Posm samples (n = 126 pairs). Thirty‐two volunteers were tested multiple times while EUH (n = 115) or DEH (n = 11) by −4.0% body mass. Protinol™ (240, 280, and 320 mmol/kg) and Clinitrol™ (290 mmol/kg) reference solutions were compared similarly (n = 282 pairs). Results The 20 μL samples of plasma showed a 7 mmol/kg positive bias compared to 250 μL samples and displayed a nearly constant proportional error across the range tested (slope = 0.929). Calculated osmolarity was lower than 20 μL Posm by the same negative bias (−6.9 mmol/kg) but not different from 250 μL Posm (0.1 mmol/kg). The differences between 20 and 250 μL samples of Protinol™ were significantly higher than Clinitrol™. Conclusions These results demonstrate that Posm measured by freezing point depression will be ~7 mmol/kg higher when using 20 μL vs 250 μL sample volumes. Approximately half of this effect may be due to plasma proteins. Posm sample volume should be carefully considered when calculating the osmole gap or assessing hydration status.
Collapse
Affiliation(s)
- Kurt J Sollanek
- Department of Kinesiology, Sonoma State University, Rohnert Park, California
| | - Robert W Kenefick
- U.S. Army Research Institute of Environmental Medicine, Natick, Massachusetts
| | - Samuel N Cheuvront
- U.S. Army Research Institute of Environmental Medicine, Natick, Massachusetts
| |
Collapse
|
17
|
Fish MB, Fromen CA, Lopez-Cazares G, Golinski AW, Scott TF, Adili R, Holinstat M, Eniola-Adefeso O. Exploring deformable particles in vascular-targeted drug delivery: Softer is only sometimes better. Biomaterials 2017; 124:169-179. [PMID: 28209527 PMCID: PMC5341378 DOI: 10.1016/j.biomaterials.2017.02.002] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2016] [Revised: 01/31/2017] [Accepted: 02/01/2017] [Indexed: 10/20/2022]
Abstract
The ability of vascular-targeted drug carriers (VTCs) to localize and bind to a targeted, diseased endothelium determines their overall clinical utility. Here, we investigate how particle modulus and size determine adhesion of VTCs to the vascular wall under physiological blood flow conditions. In general, deformable microparticles (MPs) outperformed nanoparticles (NPs) in all experimental conditions tested. Our results indicate that MP modulus enhances particle adhesion in a shear-dependent manner. In low shear human blood flow profiles in vitro, low modulus particles showed favorable adhesion, while at high shear, rigid particles showed superior adhesion. This was confirmed in vivo by studying particle adhesion under venous shear profiles in a mouse model of mesenteric inflammation, where MP adhesion was 127% greater (p < 0.0001) for low modulus particles compared to more rigid ones. Mechanistically, we establish that particle collisions with leukocytes drive these trends, rather than differences in particle deformation, localization, or detachment. Overall, this work demonstrates the importance of VTC modulus as a design parameter for enhanced VTC interaction with vascular walls, and thus, contributes important knowledge for development of successful clinical theranostics with applications for many diseases.
Collapse
Affiliation(s)
- Margaret B Fish
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Catherine A Fromen
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Genesis Lopez-Cazares
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Alexander W Golinski
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Timothy F Scott
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, United States; Macromolecular Science and Engineering Program, University of Michigan, Ann Arbor, MI 48109, United States
| | - Reheman Adili
- Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, United States
| | - Michael Holinstat
- Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, United States; Department of Cardiovascular Medicine, Samuel and Jean Frankel Cardiovascular Center, University of Michigan, Ann Arbor, MI 48109, United States
| | - Omolola Eniola-Adefeso
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, United States; Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, United States; Macromolecular Science and Engineering Program, University of Michigan, Ann Arbor, MI 48109, United States.
| |
Collapse
|
18
|
Wittbrodt MT, Espinoza S, Millard-Stafford ML. Biological variation of plasma osmolality obtained with capillary versus venous blood. Clin Chem Lab Med 2016; 53:1613-9. [PMID: 25720122 DOI: 10.1515/cclm-2014-1006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2014] [Accepted: 01/01/2015] [Indexed: 11/15/2022]
Abstract
BACKGROUND Plasma osmolality (POsm) is a gold standard to assess hydration status but requires venipuncture. POsm obtained by lancing a digit, a source of capillary puncture blood (CAP), has not been validated. This study compared POsm from CAP versus venous blood (VEN) and validated its sensitivity to detect dehydration. METHODS Healthy young adults (Study A: n=20 men, 22 women; Study B: n=23 men, 23 women) participated. In Study A, CAP and VEN were compared under controlled euhydration meeting dietary reference intakes for water (3.7 L men, 2.7 L women). In Study B, CAP was assessed for sensitivity to detect dehydration with receiver operating characteristic analysis over two 24 h periods: euhydration for 24 h followed by water restriction over 24 h. POsm was measured using freezing point depression. RESULTS For all subjects, CAP POsm (283.0±3.9 mOsm/kg) was not significantly different (p=0.07) from VEN (284.2±3.5) during euhydration and met analytical goals for individuality and heterogeneity. When outliers (n=3) were eliminated, mean difference was -1.6 (±3.2) lower (p<0.01) with CAP. Fluid restriction increased (p<0.001) CAP POsm (284.0±4.4 to 292.8±5.2 mOsm/kg), achieving excellent accuracy (0.92) and sensitivity (89.1%) to predict mild dehydration (2% body mass loss). CONCLUSIONS POsm via CAP exhibited similar coefficients of variation and analytical goals compared to VEN combined with excellent accuracy and sensitivity to detect dehydration. Although CAP values were approximately 2 mOsm/kg lower than VEN, CAP appears an adequate substitute for tracking changes in non-clinical settings.
Collapse
|
19
|
Heathman TRJ, Stolzing A, Fabian C, Rafiq QA, Coopman K, Nienow AW, Kara B, Hewitt CJ. Serum-free process development: improving the yield and consistency of human mesenchymal stromal cell production. Cytotherapy 2016; 17:1524-35. [PMID: 26432558 DOI: 10.1016/j.jcyt.2015.08.002] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Revised: 07/22/2015] [Accepted: 08/03/2015] [Indexed: 10/23/2022]
Abstract
BACKGROUND AIMS The cost-effective production of human mesenchymal stromal cells (hMSCs) for off-the-shelf and patient specific therapies will require an increasing focus on improving product yield and driving manufacturing consistency. METHODS Bone marrow-derived hMSCs (BM-hMSCs) from two donors were expanded for 36 days in monolayer with medium supplemented with either fetal bovine serum (FBS) or PRIME-XV serum-free medium (SFM). Cells were assessed throughout culture for proliferation, mean cell diameter, colony-forming potential, osteogenic potential, gene expression and metabolites. RESULTS Expansion of BM-hMSCs in PRIME-XV SFM resulted in a significantly higher growth rate (P < 0.001) and increased consistency between donors compared with FBS-based culture. FBS-based culture showed an inter-batch production range of 0.9 and 5 days per dose compared with 0.5 and 0.6 days in SFM for each BM-hMSC donor line. The consistency between donors was also improved by the use of PRIME-XV SFM, with a production range of 0.9 days compared with 19.4 days in FBS-based culture. Mean cell diameter has also been demonstrated as a process metric for BM-hMSC growth rate and senescence through a correlation (R(2) = 0.8705) across all conditions. PRIME-XV SFM has also shown increased consistency in BM-hMSC characteristics such as per cell metabolite utilization, in vitro colony-forming potential and osteogenic potential despite the higher number of population doublings. CONCLUSIONS We have increased the yield and consistency of BM-hMSC expansion between donors, demonstrating a level of control over the product, which has the potential to increase the cost-effectiveness and reduce the risk in these manufacturing processes.
Collapse
Affiliation(s)
- Thomas R J Heathman
- Centre for Biological Engineering, Loughborough University, Leicestershire, United Kingdom
| | - Alexandra Stolzing
- Centre for Biological Engineering, Loughborough University, Leicestershire, United Kingdom
| | - Claire Fabian
- Fraunhofer Institute for Cell Therapy and Immunology, Leipzig, Germany; Translational Centre for Regenerative Medicine, Leipzig University, Leipzig, Germany
| | - Qasim A Rafiq
- Centre for Biological Engineering, Loughborough University, Leicestershire, United Kingdom; Aston Medical Research Institute, School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham, United Kingdom
| | - Karen Coopman
- Centre for Biological Engineering, Loughborough University, Leicestershire, United Kingdom
| | - Alvin W Nienow
- Centre for Biological Engineering, Loughborough University, Leicestershire, United Kingdom; Centre for Bioprocess Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Bo Kara
- FUJIFILM Diosynth Biotechnologies, Billingham, United Kingdom
| | - Christopher J Hewitt
- Centre for Biological Engineering, Loughborough University, Leicestershire, United Kingdom; Aston Medical Research Institute, School of Life and Health Sciences, Aston University, Aston Triangle, Birmingham, United Kingdom.
| |
Collapse
|
20
|
Hooper L, Abdelhamid A, Ali A, Bunn DK, Jennings A, John WG, Kerry S, Lindner G, Pfortmueller CA, Sjöstrand F, Walsh NP, Fairweather-Tait SJ, Potter JF, Hunter PR, Shepstone L. Diagnostic accuracy of calculated serum osmolarity to predict dehydration in older people: adding value to pathology laboratory reports. BMJ Open 2015; 5:e008846. [PMID: 26490100 PMCID: PMC4636668 DOI: 10.1136/bmjopen-2015-008846] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2015] [Revised: 08/26/2015] [Accepted: 09/18/2015] [Indexed: 01/09/2023] Open
Abstract
OBJECTIVES To assess which osmolarity equation best predicts directly measured serum/plasma osmolality and whether its use could add value to routine blood test results through screening for dehydration in older people. DESIGN Diagnostic accuracy study. PARTICIPANTS Older people (≥65 years) in 5 cohorts: Dietary Strategies for Healthy Ageing in Europe (NU-AGE, living in the community), Dehydration Recognition In our Elders (DRIE, living in residential care), Fortes (admitted to acute medical care), Sjöstrand (emergency room) or Pfortmueller cohorts (hospitalised with liver cirrhosis). REFERENCE STANDARD FOR HYDRATION STATUS Directly measured serum/plasma osmolality: current dehydration (serum osmolality>300 mOsm/kg), impending/current dehydration (≥295 mOsm/kg). INDEX TESTS 39 osmolarity equations calculated using serum indices from the same blood draw as directly measured osmolality. RESULTS Across 5 cohorts 595 older people were included, of whom 19% were dehydrated (directly measured osmolality>300 mOsm/kg). Of 39 osmolarity equations, 5 showed reasonable agreement with directly measured osmolality and 3 had good predictive accuracy in subgroups with diabetes and poor renal function. Two equations were characterised by narrower limits of agreement, low levels of differential bias and good diagnostic accuracy in receiver operating characteristic plots (areas under the curve>0.8). The best equation was osmolarity=1.86×(Na++K+)+1.15×glucose+urea+14 (all measured in mmol/L). It appeared useful in people aged ≥65 years with and without diabetes, poor renal function, dehydration, in men and women, with a range of ages, health, cognitive and functional status. CONCLUSIONS Some commonly used osmolarity equations work poorly, and should not be used. Given costs and prevalence of dehydration in older people we suggest use of the best formula by pathology laboratories using a cutpoint of 295 mOsm/L (sensitivity 85%, specificity 59%), to report dehydration risk opportunistically when serum glucose, urea and electrolytes are measured for other reasons in older adults. TRIAL REGISTRATION NUMBERS DRIE: Research Register for Social Care, 122273; NU-AGE: ClinicalTrials.gov NCT01754012.
Collapse
Affiliation(s)
- Lee Hooper
- Norwich Medical School, University of East Anglia, Norwich, UK
| | | | - Adam Ali
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Diane K Bunn
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Amy Jennings
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - W Garry John
- Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK
| | - Susan Kerry
- Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK
| | - Gregor Lindner
- Department of General Internal Medicine, Inselspital, University Hospital Bern, Bern, Switzerland
| | - Carmen A Pfortmueller
- Department of General Anesthesiology, Intensive Care and Pain Management, Medical University of Vienna, Vienna, Austria
| | - Fredrik Sjöstrand
- Department of Emergency Medicine, Södersjukhuset AB, Stockholm, Sweden
| | - Neil P Walsh
- College of Health and Behavioural Sciences, Bangor University, Bangor, UK
| | | | - John F Potter
- Norwich Medical School, University of East Anglia, Norwich, UK
- Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK
| | - Paul R Hunter
- Norwich Medical School, University of East Anglia, Norwich, UK
- Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK
| | - Lee Shepstone
- Norwich Medical School, University of East Anglia, Norwich, UK
| |
Collapse
|
21
|
Heavens KR, Kenefick RW, Caruso EM, Spitz MG, Cheuvront SN. Validation of equations used to predict plasma osmolality in a healthy adult cohort. Am J Clin Nutr 2014; 100:1252-6. [PMID: 25332323 DOI: 10.3945/ajcn.114.091009] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Plasma osmometry and the osmol gap have long been used to provide clinicians with important diagnostic and prognostic patient information. OBJECTIVE We compared different equations used for predicting plasma osmolality when its direct measurement was not practical or an osmol gap was of interest and identified the best performers. DESIGN The osmolality of plasma was measured by using freezing point depression by microosmometer and osmolarity calculated from biosensor measures of select analytes according to the dictates of each formula tested. After a rigid analytic prescreen of 36 originally published equations, a bootstrap regression analysis was used to compare shrinkage and model agreement. RESULTS Sixty healthy volunteers provided 163 plasma samples for analysis. Of 36 equations considered, 11 equations met the prescreen variables for the bootstrap regression analysis. Of the 11 equations, 8 equations met shrinkage and apparent model error thresholds, and 5 equations were deemed optimal with an original model osmol gap <5 mmol. CONCLUSIONS The use of bootstrap regression provides a unique insight for osmolality prediction equation performance from a very large theoretical population of healthy people. Of the original 36 equations evaluated, 5 equations appeared optimal for the prediction of osmolality when its direct measurement was not practical or an osmol gap was of interest. Note that 4 of 5 optimal equations were derived from a nonhealthy population.
Collapse
Affiliation(s)
- Kristen R Heavens
- From the US Army Research Institute of Environmental Medicine, Natick, MA
| | - Robert W Kenefick
- From the US Army Research Institute of Environmental Medicine, Natick, MA
| | - Elizabeth M Caruso
- From the US Army Research Institute of Environmental Medicine, Natick, MA
| | - Marissa G Spitz
- From the US Army Research Institute of Environmental Medicine, Natick, MA
| | - Samuel N Cheuvront
- From the US Army Research Institute of Environmental Medicine, Natick, MA
| |
Collapse
|
22
|
Siervo M, Bunn D, Prado CM, Hooper L. Accuracy of prediction equations for serum osmolarity in frail older people with and without diabetes. Am J Clin Nutr 2014; 100:867-76. [PMID: 25030781 PMCID: PMC4135495 DOI: 10.3945/ajcn.114.086769] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
BACKGROUND Serum osmolality is an accurate indicator of hydration status in older adults. Glucose, urea, and electrolyte concentrations are used to calculate serum osmolarity, which is an indirect estimate of serum osmolality, but which serum osmolarity equations best predict serum osmolality in the elderly is unclear. OBJECTIVE We assessed the agreement of measured serum osmolality with calculated serum osmolarity equations in older people. DESIGN Serum osmolality was measured by using freezing point depression in a cross-sectional study. Plasma glucose, urea, and electrolytes were analyzed and entered into 38 serum osmolarity-prediction equations. The Bland-Altman method was used to evaluate the agreement and differential bias between measured osmolality and calculated osmolarity. The sensitivity and specificity of the most-promising equations were examined against serum osmolality (reference standard). RESULTS A total of 186 people living in UK residential care took part in the Dehydration Recognition In our Elders study (66% women; mean ± SD age: 85.8 ± 7.9 y; with a range of cognitive and physical impairments) and were included in analyses. Forty-six percent of participants had impending or current dehydration (serum osmolality ≥295 mmol/kg). Participants with diabetes (n = 33; 18%) had higher glucose (P < 0.001) and serum osmolality (P < 0.01). Of 38 predictive equations used to calculate osmolarity, 4 equations showed reasonable agreement with measured osmolality. One [calculated osmolarity = 1.86 × (Na⁺ + K⁺) + 1.15 × glucose + urea +14; all in mmol/L] was characterized by narrower limits of agreement and the capacity to predict serum osmolality within 2% in >80% of participants, regardless of diabetes or hydration status. The equation's sensitivity (79%) and specificity (89%) for impending dehydration (≥295 mmol/kg) and current dehydration (>300 mmol/kg) (69% and 93%, respectively) were reasonable. CONCLUSIONS The assessment of a panel of equations for the prediction of serum osmolarity led to identification of one formula with a greater diagnostic performance. This equation may be used to predict hydration status in frail older people (as a first-stage screening) or to estimate hydration status in population studies. This trial was registered at the Research Register for Social Care (http://www.researchregister.org.uk) as 122273.
Collapse
Affiliation(s)
- Mario Siervo
- From the Human Nutrition Research Centre, Institute for Ageing and Health, Newcastle University, Newcastle on Tyne, United Kingdom (MS); the Norwich Medical School, University of East Anglia, Norwich, United Kingdom (DB and LH); and the Department of Agricultural, Food and Nutritional Sciences, University of Alberta, Edmonton, Canada (CMP)
| | - Diane Bunn
- From the Human Nutrition Research Centre, Institute for Ageing and Health, Newcastle University, Newcastle on Tyne, United Kingdom (MS); the Norwich Medical School, University of East Anglia, Norwich, United Kingdom (DB and LH); and the Department of Agricultural, Food and Nutritional Sciences, University of Alberta, Edmonton, Canada (CMP)
| | - Carla M Prado
- From the Human Nutrition Research Centre, Institute for Ageing and Health, Newcastle University, Newcastle on Tyne, United Kingdom (MS); the Norwich Medical School, University of East Anglia, Norwich, United Kingdom (DB and LH); and the Department of Agricultural, Food and Nutritional Sciences, University of Alberta, Edmonton, Canada (CMP)
| | - Lee Hooper
- From the Human Nutrition Research Centre, Institute for Ageing and Health, Newcastle University, Newcastle on Tyne, United Kingdom (MS); the Norwich Medical School, University of East Anglia, Norwich, United Kingdom (DB and LH); and the Department of Agricultural, Food and Nutritional Sciences, University of Alberta, Edmonton, Canada (CMP)
| |
Collapse
|