Berglund J, Liljeblad M, Baron T. Unwrapping phase contrast MRI by iterative graph cuts. Magn Reson Med 2024; 92:1484-1495. [PMID: 38725423 DOI: 10.1002/mrm.30138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 04/10/2024] [Accepted: 04/15/2024] [Indexed: 07/23/2024]
Abstract
PURPOSE To develop and evaluate a phase unwrapping method for cine phase contrast MRI based on graph cuts. METHODS A proposed Iterative Graph Cuts method was evaluated in 10 cardiac patients with two-dimensional flow quantification which was repeated at low venc settings to provoke wrapping. The images were also unwrapped by a path-following method (ROMEO), and a Laplacian-based method (LP). Net flow was quantified using semi-automatic vessel segmentation. High venc images were also wrapped retrospectively to asses the residual amount of wrapped voxels. RESULTS The absolute net flow error after unwrapping at venc = 100 cm/s was 1.8 mL, which was 0.83 mL smaller than for LP. The repeatability error at high venc without unwrapping was 2.5 mL. The error at venc = 50 cm/s was 7.5 mL, which was 8.2 mL smaller than for ROMEO and 5.7 mL smaller than for LP. For retrospectively wrapped images with synthetic venc of 100/50/25 cm/s, the residual amount of wrapped voxels was 0.00/0.12/0.79%, which was 0.09/0.26/8.0 percentage points smaller than for LP. With synthetic venc of 25 cm/s, omitting magnitude information resulted in 3.2 percentage points more wrapped voxels, and only spatial/temporal unwrapping resulted in 4.6/21 percentage points more wrapped voxels compared to spatiotemporal unwrapping. CONCLUSION Iterative Graph Cuts enables unwrapping of cine phase contrast MRI with very small errors, except for at extreme blood velocities, with equal or better performance compared to ROMEO and LP. The use of magnitude information and spatiotemporal unwrapping is recommended.
Collapse
Affiliation(s)
- Johan Berglund
- Medical Physics, Uppsala University Hospital, Uppsala, Sweden
- Molecular Imaging and Medical Physics, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Mio Liljeblad
- Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| | - Tomasz Baron
- Cardiology and Clinical Physiology, Department of Medical Sciences, Uppsala University, Uppsala, Sweden
- Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden
| |
Collapse
|
2
|
Riva A, Saitta S, Sturla F, Disabato G, Tondi L, Camporeale A, Giese D, Castelvecchio S, Menicanti L, Redaelli A, Lombardi M, Votta E. Left ventricle diastolic vortex ring characterization in ischemic cardiomyopathy: insight into atrio-ventricular interplay. Med Biol Eng Comput 2024:10.1007/s11517-024-03154-4. [PMID: 38954265 DOI: 10.1007/s11517-024-03154-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 06/10/2024] [Indexed: 07/04/2024]
Abstract
Diastolic vortex ring (VR) plays a key role in the blood-pumping function exerted by the left ventricle (LV), with altered VR structures being associated with LV dysfunction. Herein, we sought to characterize the VR diastolic alterations in ischemic cardiomyopathy (ICM) patients with systo-diastolic LV dysfunction, as compared to healthy controls, in order to provide a more comprehensive understanding of LV diastolic function. 4D Flow MRI data were acquired in ICM patients (n = 15) and healthy controls (n = 15). The λ2 method was used to extract VRs during early and late diastolic filling. Geometrical VR features, e.g., circularity index (CI), orientation (α), and inclination with respect to the LV outflow tract (ß), were extracted. Kinetic energy (KE), rate of viscous energy loss ( EL ˙ ), vorticity (W), and volume (V) were computed for each VR; the ratios with the respective quantities computed for the entire LV were derived. At peak E-wave, the VR was less circular (p = 0.032), formed a smaller α with the LV long-axis (p = 0.003) and a greater ß (p = 0.002) in ICM patients as compared to controls. At peak A-wave, CI was significantly increased (p = 0.034), while α was significantly smaller (p = 0.016) and β was significantly increased (p = 0.036) in ICM as compared to controls. At both peak E-wave and peak A-wave,EL ˙ VR / EL ˙ LV , WVR/WLV, and VVR/VLV significantly decreased in ICM patients vs. healthy controls. KEVR/VVR showed a significant decrease in ICM patients with respect to controls at peak E-wave, while VVR remained comparable between normal and pathologic conditions. In the analyzed ICM patients, the diastolic VRs showed alterations in terms of geometry and energetics. These derangements might be attributed to both structural and functional alterations affecting the infarcted wall region and the remote myocardium.
Collapse
Affiliation(s)
- Alessandra Riva
- 3D and Computer Simulation Laboratory, IRCCS, Policlinico San Donato, Piazza E. Malan 2, San Donato Milanese, Italy
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
| | - Simone Saitta
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
| | - Francesco Sturla
- 3D and Computer Simulation Laboratory, IRCCS, Policlinico San Donato, Piazza E. Malan 2, San Donato Milanese, Italy.
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy.
| | - Giandomenico Disabato
- Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Lara Tondi
- Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, San Donato Milanese, Italy
- Department of Radiology, IRCCS Foundation Ca' Granda Ospedale Maggiore Policlinico, University of Milan, Milan, Italy
| | - Antonia Camporeale
- Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Daniel Giese
- Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany
| | | | - Lorenzo Menicanti
- Cardiac Surgery Department, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
| | - Massimo Lombardi
- Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Emiliano Votta
- 3D and Computer Simulation Laboratory, IRCCS, Policlinico San Donato, Piazza E. Malan 2, San Donato Milanese, Italy
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
| |
Collapse
|
3
|
Löcke M, Garay Labra JE, Franco P, Uribe S, Bertoglio C. A comparison of phase unwrapping methods in velocity-encoded MRI for aortic flows. Magn Reson Med 2023; 90:2102-2115. [PMID: 37345719 DOI: 10.1002/mrm.29767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 04/17/2023] [Accepted: 05/30/2023] [Indexed: 06/23/2023]
Abstract
PURPOSE The phase of a MRI signal is used to encode the velocity of blood flow. Phase unwrapping artifacts may appear when aiming to improve the velocity-to-noise ratio (VNR) of the measured velocity field. This study aims to compare various unwrapping algorithms on ground-truth synthetic data generated using computational fluid dynamics (CFD) simulations. METHODS We compare four different phase unwrapping algorithms on two different synthetic datasets of four-dimensional flow MRI and 26 datasets of 2D PC-MRI acquisitions including the ascending and descending aorta. The synthetic datasets are constructed using CFD simulations of an aorta with a coarctation, with different levels of spatiotemporal resolutions and noise. The error of the unwrapped images was assessed by comparison against the ground truth velocity field in the synthetic data and dual-VENC reconstructions in the in vivo data. RESULTS Using the unwrapping algorithms, we were able to remove aliased voxels in the data almost entirely, reducing the L2-error compared to the ground truth by 50%-80%. Results indicated that the best choice of algorithm depend on the spatiotemporal resolution and noise level of the dataset. Temporal unwrapping is most successful with a high temporal and low spatial resolution (δ t = 30 $$ \delta t=30 $$ ms,h = 2 . 5 $$ h=2.5 $$ mm), reducing the L2-error by 70%-85%, while Laplacian unwrapping performs better with a lower temporal or better spatial resolution (δ t = 60 $$ \delta t=60 $$ ms,h = 1 . 5 $$ h=1.5 $$ mm), especially for signal-to-noise ratio (SNR) 12 as opposed to SNR 15, with an error reduction of 55%-85% compared to the 50%-75% achieved by the Temporal method. The differences in performance between the methods are statistically significant. CONCLUSIONS The temporal method and spatiotemporal Laplacian method provide the best results, with the spatiotemporal Laplacian being more robust. However, single-V enc $$ {V}_{\mathrm{enc}} $$ methods only situationally and not generally reach the performance of dual-V enc $$ {V}_{\mathrm{enc}} $$ unwrapping methods.
Collapse
Affiliation(s)
- Miriam Löcke
- Bernoulli Institute, University of Groningen, Groningen, Groningen, The Netherlands
| | | | - Pamela Franco
- Biomedical Imaging Center, School of Engineering, Universidad Católica de Chile, Santiago, Región Metropolitana de Santiago, Chile
| | - Sergio Uribe
- Biomedical Imaging Center, School of Engineering, Universidad Católica de Chile, Santiago, Región Metropolitana de Santiago, Chile
| | - Cristóbal Bertoglio
- Bernoulli Institute, University of Groningen, Groningen, Groningen, The Netherlands
| |
Collapse
|
4
|
Wieben O, Roberts GS, Corrado PA, Johnson KM, Roldán-Alzate A. Four-Dimensional Flow MR Imaging: Technique and Advances. Magn Reson Imaging Clin N Am 2023; 31:433-449. [PMID: 37414470 DOI: 10.1016/j.mric.2023.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
4D Flow MRI is an advanced imaging technique for comprehensive non-invasive assessment of the cardiovascular system. The capture of the blood velocity vector field throughout the cardiac cycle enables measures of flow, pulse wave velocity, kinetic energy, wall shear stress, and more. Advances in hardware, MRI data acquisition and reconstruction methodology allow for clinically feasible scan times. The availability of 4D Flow analysis packages allows for more widespread use in research and the clinic and will facilitate much needed multi-center, multi-vendor studies in order to establish consistency across scanner platforms and to enable larger scale studies to demonstrate clinical value.
Collapse
Affiliation(s)
- Oliver Wieben
- Department of Medical Physics, University of Wisconsin-Madison, Wisconsin Institutes for Medical Research, 1111 Highland Avenue, Suite 1127, Madison, WI 53705-2275, USA; Department of Radiology, University of Wisconsin-Madison, Wisconsin Institutes for Medical Research, 1111 Highland Avenue, Suite 1127, Madison, WI 53705-2275, USA.
| | - Grant S Roberts
- Department of Medical Physics, University of Wisconsin-Madison, Wisconsin Institutes for Medical Research, 1111 Highland Avenue, Madison, WI 53705-2275, USA
| | - Philip A Corrado
- Accuray Incorporated, 1414 Raleigh Road, Suite 330, DurhamChapel Hill, NC 27517, USA
| | - Kevin M Johnson
- Department of Medical Physics, University of Wisconsin-Madison, Wisconsin Institutes for Medical Research, 1111 Highland Avenue, Room 1133, Madison, WI 53705-2275, USA; Department of Radiology, University of Wisconsin-Madison, Wisconsin Institutes for Medical Research, 1111 Highland Avenue, Room 1133, Madison, WI 53705-2275, USA
| | - Alejandro Roldán-Alzate
- Department of Mechanical Engineering, University of Wisconsin-Madison, Room: 3035, 1513 University Avenue, Madison, WI 53706, USA; Department of Radiology, University of Wisconsin-Madison, Madison, WI, USA
| |
Collapse
|
5
|
van Amerom JFP, Goolaub DS, Schrauben EM, Sun L, Macgowan CK, Seed M. Fetal cardiovascular blood flow MRI: techniques and applications. Br J Radiol 2023; 96:20211096. [PMID: 35687661 PMCID: PMC10321246 DOI: 10.1259/bjr.20211096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 05/11/2022] [Accepted: 05/24/2022] [Indexed: 11/05/2022] Open
Abstract
Fetal cardiac MRI is challenging due to fetal and maternal movements as well as the need for a reliable cardiac gating signal and high spatiotemporal resolution. Ongoing research and recent technical developments to address these challenges show the potential of MRI as an adjunct to ultrasound for the assessment of the fetal heart and great vessels. MRI measurements of blood flow have enabled the assessment of normal fetal circulation as well as conditions with disrupted circulations, such as congenital heart disease, along with associated organ underdevelopment and hemodynamic instability. This review provides details of the techniques used in fetal cardiovascular blood flow MRI, including single slice and volumetric imaging sequences, post-processing and analysis, along with a summary of applications in human studies and animal models.
Collapse
Affiliation(s)
- Joshua FP van Amerom
- Division of Translational Medicine, SickKids Research Institute, Toronto, Canada
| | | | - Eric M Schrauben
- Department of Radiology & Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | | | | | | |
Collapse
|
6
|
Bustamante M, Viola F, Engvall J, Carlhäll C, Ebbers T. Automatic Time-Resolved Cardiovascular Segmentation of 4D Flow MRI Using Deep Learning. J Magn Reson Imaging 2023; 57:191-203. [PMID: 35506525 PMCID: PMC10946960 DOI: 10.1002/jmri.28221] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 04/14/2022] [Accepted: 04/15/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Segmenting the whole heart over the cardiac cycle in 4D flow MRI is a challenging and time-consuming process, as there is considerable motion and limited contrast between blood and tissue. PURPOSE To develop and evaluate a deep learning-based segmentation method to automatically segment the cardiac chambers and great thoracic vessels from 4D flow MRI. STUDY TYPE Retrospective. SUBJECTS A total of 205 subjects, including 40 healthy volunteers and 165 patients with a variety of cardiac disorders were included. Data were randomly divided into training (n = 144), validation (n = 20), and testing (n = 41) sets. FIELD STRENGTH/SEQUENCE A 3 T/time-resolved velocity encoded 3D gradient echo sequence (4D flow MRI). ASSESSMENT A 3D neural network based on the U-net architecture was trained to segment the four cardiac chambers, aorta, and pulmonary artery. The segmentations generated were compared to manually corrected atlas-based segmentations. End-diastolic (ED) and end-systolic (ES) volumes of the four cardiac chambers were calculated for both segmentations. STATISTICAL TESTS Dice score, Hausdorff distance, average surface distance, sensitivity, precision, and miss rate were used to measure segmentation accuracy. Bland-Altman analysis was used to evaluate agreement between volumetric parameters. RESULTS The following evaluation metrics were computed: mean Dice score (0.908 ± 0.023) (mean ± SD), Hausdorff distance (1.253 ± 0.293 mm), average surface distance (0.466 ± 0.136 mm), sensitivity (0.907 ± 0.032), precision (0.913 ± 0.028), and miss rate (0.093 ± 0.032). Bland-Altman analyses showed good agreement between volumetric parameters for all chambers. Limits of agreement as percentage of mean chamber volume (LoA%), left ventricular: 9.3%, 13.5%, left atrial: 12.4%, 16.9%, right ventricular: 9.9%, 15.6%, and right atrial: 18.7%, 14.4%; for ED and ES, respectively. DATA CONCLUSION The addition of this technique to the 4D flow MRI assessment pipeline could expedite and improve the utility of this type of acquisition in the clinical setting. EVIDENCE LEVEL 4 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Mariana Bustamante
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
- Center for Medical Image Science and Visualization (CMIV)Linköping UniversityLinköpingSweden
| | - Federica Viola
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
| | - Jan Engvall
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
- Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
| | - Carl‐Johan Carlhäll
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
- Center for Medical Image Science and Visualization (CMIV)Linköping UniversityLinköpingSweden
- Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
| | - Tino Ebbers
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
- Center for Medical Image Science and Visualization (CMIV)Linköping UniversityLinköpingSweden
| |
Collapse
|
7
|
Peper ES, van Ooij P, Jung B, Huber A, Gräni C, Bastiaansen JAM. Advances in machine learning applications for cardiovascular 4D flow MRI. Front Cardiovasc Med 2022; 9:1052068. [PMID: 36568555 PMCID: PMC9780299 DOI: 10.3389/fcvm.2022.1052068] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 11/22/2022] [Indexed: 12/13/2022] Open
Abstract
Four-dimensional flow magnetic resonance imaging (MRI) has evolved as a non-invasive imaging technique to visualize and quantify blood flow in the heart and vessels. Hemodynamic parameters derived from 4D flow MRI, such as net flow and peak velocities, but also kinetic energy, turbulent kinetic energy, viscous energy loss, and wall shear stress have shown to be of diagnostic relevance for cardiovascular diseases. 4D flow MRI, however, has several limitations. Its long acquisition times and its limited spatio-temporal resolutions lead to inaccuracies in velocity measurements in small and low-flow vessels and near the vessel wall. Additionally, 4D flow MRI requires long post-processing times, since inaccuracies due to the measurement process need to be corrected for and parameter quantification requires 2D and 3D contour drawing. Several machine learning (ML) techniques have been proposed to overcome these limitations. Existing scan acceleration methods have been extended using ML for image reconstruction and ML based super-resolution methods have been used to assimilate high-resolution computational fluid dynamic simulations and 4D flow MRI, which leads to more realistic velocity results. ML efforts have also focused on the automation of other post-processing steps, by learning phase corrections and anti-aliasing. To automate contour drawing and 3D segmentation, networks such as the U-Net have been widely applied. This review summarizes the latest ML advances in 4D flow MRI with a focus on technical aspects and applications. It is divided into the current status of fast and accurate 4D flow MRI data generation, ML based post-processing tools for phase correction and vessel delineation and the statistical evaluation of blood flow.
Collapse
Affiliation(s)
- Eva S. Peper
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland,Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland,*Correspondence: Eva S. Peper,
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Amsterdam, Netherlands,Department of Pediatric Cardiology, Wilhelmina Children’s Hospital, University Medical Center Utrecht, Utrecht, Netherlands
| | - Bernd Jung
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland,Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Adrian Huber
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Christoph Gräni
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Jessica A. M. Bastiaansen
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland,Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| |
Collapse
|
8
|
Berhane H, Scott MB, Barker AJ, McCarthy P, Avery R, Allen B, Malaisrie C, Robinson JD, Rigsby CK, Markl M. Deep learning-based velocity antialiasing of 4D-flow MRI. Magn Reson Med 2022; 88:449-463. [PMID: 35381116 PMCID: PMC9050855 DOI: 10.1002/mrm.29205] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Revised: 01/13/2022] [Accepted: 02/07/2022] [Indexed: 01/03/2023]
Abstract
Purpose To develop a convolutional neural network (CNN) for the robust and fast correction of velocity aliasing in 4D‐flow MRI. Methods This study included 667 adult subjects with aortic 4D‐flow MRI data with existing velocity aliasing (n = 362) and no velocity aliasing (n = 305). Additionally, 10 controls received back‐to‐back 4D‐flow scans with systemically varied velocity‐encoding sensitivity (vencs) at 60, 100, and 175 cm/s. The no‐aliasing data sets were used to simulate velocity aliasing by reducing the venc to 40%–70% of the original, alongside a ground truth locating all aliased voxels (153 training, 152 testing). The 152 simulated and 362 existing aliasing data sets were used for testing and compared with a conventional velocity antialiasing algorithm. Dice scores were calculated to quantify CNN performance. For controls, the venc 175‐cm/s scans were used as the ground truth and compared with the CNN‐corrected venc 60 and 100 cm/s data sets Results The CNN required 176 ± 30 s to perform compared with 162 ± 14 s for the conventional algorithm. The CNN showed excellent performance for the simulated data compared with the conventional algorithm (median range of Dice scores CNN: [0.89–0.99], conventional algorithm: [0.84–0.94], p < 0.001, across all simulated vencs) and detected more aliased voxels in existing velocity aliasing data sets (median detected CNN: 159 voxels [31–605], conventional algorithm: 65 [7–417], p < 0.001). For controls, the CNN showed Dice scores of 0.98 [0.95–0.99] and 0.96 [0.87–0.99] for venc = 60 cm/s and 100 cm/s, respectively, while flow comparisons showed moderate‐excellent agreement. Conclusion Deep learning enabled fast and robust velocity anti‐aliasing in 4D‐flow MRI.
Collapse
Affiliation(s)
- Haben Berhane
- Department of Biomedical EngineeringNorthwestern UniversityEvanstonIllinoisUSA
- Department of RadiologyNorthwestern MedicineChicagoIllinoisUSA
| | - Michael B. Scott
- Department of Biomedical EngineeringNorthwestern UniversityEvanstonIllinoisUSA
- Department of RadiologyNorthwestern MedicineChicagoIllinoisUSA
| | - Alex J. Barker
- Anschutz Medical CampusUniversity of ColoradoAuroraColoradoUSA
| | - Patrick McCarthy
- Division of Cardiac SurgeryNorthwestern MedicineChicagoIllinoisUSA
| | - Ryan Avery
- Department of RadiologyNorthwestern MedicineChicagoIllinoisUSA
| | - Brad Allen
- Department of RadiologyNorthwestern MedicineChicagoIllinoisUSA
| | - Chris Malaisrie
- Division of Cardiac SurgeryNorthwestern MedicineChicagoIllinoisUSA
| | - Joshua D. Robinson
- Department of Medical ImagingLurie Children's Hospital of ChicagoChicagoIllinoisUSA
| | - Cynthia K. Rigsby
- Department of RadiologyNorthwestern MedicineChicagoIllinoisUSA
- Department of Medical ImagingLurie Children's Hospital of ChicagoChicagoIllinoisUSA
| | - Michael Markl
- Department of Biomedical EngineeringNorthwestern UniversityEvanstonIllinoisUSA
- Department of RadiologyNorthwestern MedicineChicagoIllinoisUSA
| |
Collapse
|
9
|
Whittaker JR, Fasano F, Venzi M, Liebig P, Gallichan D, Möller HE, Murphy K. Measuring Arterial Pulsatility With Dynamic Inflow Magnitude Contrast. Front Neurosci 2022; 15:795749. [PMID: 35110991 PMCID: PMC8802674 DOI: 10.3389/fnins.2021.795749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 12/22/2021] [Indexed: 11/13/2022] Open
Abstract
The pulsatility of blood flow through cerebral arteries is clinically important, as it is intrinsically associated with cerebrovascular health. In this study we outline a new MRI approach to measuring the real-time pulsatile flow in cerebral arteries, which is based on the inflow phenomenon associated with fast gradient-recalled-echo acquisitions. Unlike traditional phase-contrast techniques, this new method, which we dub dynamic inflow magnitude contrast (DIMAC), does not require velocity-encoding gradients as sensitivity to flow velocity is derived purely from the inflow effect. We achieved this using a highly accelerated single slice EPI acquisition with a very short TR (15 ms) and a 90° flip angle, thus maximizing inflow contrast. We simulate the spoiled GRE signal in the presence of large arteries and perform a sensitivity analysis. The sensitivity analysis demonstrates that in the regime of high inflow contrast, DIMAC shows much greater sensitivity to flow velocity over blood volume changes. We support this theoretical prediction with in-vivo data collected in two separate experiments designed to demonstrate the utility of the DIMAC signal contrast. We perform a hypercapnia challenge experiment in order to experimentally modulate arterial tone within subjects, and thus modulate the arterial pulsatile flow waveform. We also perform a thigh-cuff release challenge, designed to induce a transient drop in blood pressure, and demonstrate that the continuous DIMAC signal captures the complex transient change in the pulsatile and non-pulsatile components of flow. In summary, this study proposes a new role for a well-established source of MR image contrast and demonstrates its potential for measuring both steady-state and dynamic changes in arterial tone.
Collapse
Affiliation(s)
- Joseph R. Whittaker
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Physics and Astronomy, Cardiff University, Cardiff, United Kingdom
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | | | - Marcello Venzi
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Physics and Astronomy, Cardiff University, Cardiff, United Kingdom
| | | | | | - Harald E. Möller
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Kevin Murphy
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Physics and Astronomy, Cardiff University, Cardiff, United Kingdom
| |
Collapse
|
10
|
Zhang J, Rothenberger SM, Brindise MC, Scott MB, Berhane H, Baraboo JJ, Markl M, Rayz VL, Vlachos PP. Divergence-Free Constrained Phase Unwrapping and Denoising for 4D Flow MRI Using Weighted Least-Squares. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3389-3399. [PMID: 34086567 PMCID: PMC8714458 DOI: 10.1109/tmi.2021.3086331] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A novel divergence-free constrained phase unwrapping method was proposed and evaluated for 4D flow MRI. The unwrapped phase field was obtained by integrating the phase variations estimated from the wrapped phase data using weighted least-squares. The divergence-free constraint for incompressible blood flow was incorporated to regulate and denoise the resulting phase field. The proposed method was tested on synthetic phase data of left ventricular flow and in vitro 4D flow measurement of Poiseuille flow. The method was additionally applied to in vivo 4D flow measurements in the thoracic aorta from 30 human subjects. The performance of the proposed method was compared to the state-of-the-art 4D single-step Laplacian algorithm. The synthetic phase data were completely unwrapped by the proposed method for all the cases with velocity encoding (venc) as low as 20% of the maximum velocity and signal-to-noise ratio as low as 5. The in vitro Poiseuille flow data were completely unwrapped with a 60% increase in the velocity-to-noise ratio. For the in-vivo aortic datasets with venc ratio less than 0.4, the proposed method significantly improved the success rate by as much as 40% and reduced the velocity error levels by a factor of 10 compared to the state-of-the-art method. The divergence-free constrained method exhibits reliability and robustness on phase unwrapping and shows improved accuracy of velocity and hemodynamic quantities by unwrapping the low-venc 4D flow MRI data.
Collapse
|
11
|
Fathi MF, Bakhshinejad A, Baghaie A, Saloner D, Sacho RH, Rayz VL, D’Souza RM. Denoising and spatial resolution enhancement of 4D flow MRI using proper orthogonal decomposition and lasso regularization. Comput Med Imaging Graph 2018; 70:165-172. [DOI: 10.1016/j.compmedimag.2018.07.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 04/17/2018] [Accepted: 07/24/2018] [Indexed: 11/15/2022]
|
12
|
Casas B, Viola F, Cedersund G, Bolger AF, Karlsson M, Carlhäll CJ, Ebbers T. Non-invasive Assessment of Systolic and Diastolic Cardiac Function During Rest and Stress Conditions Using an Integrated Image-Modeling Approach. Front Physiol 2018; 9:1515. [PMID: 30425650 PMCID: PMC6218619 DOI: 10.3389/fphys.2018.01515] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 10/09/2018] [Indexed: 01/08/2023] Open
Abstract
Background: The possibility of non-invasively assessing load-independent parameters characterizing cardiac function is of high clinical value. Typically, these parameters are assessed during resting conditions. However, for diagnostic purposes, the parameter behavior across a physiologically relevant range of heart rate and loads is more relevant than the isolated measurements performed at rest. This study sought to evaluate changes in non-invasive estimations of load-independent parameters of left-ventricular contraction and relaxation patterns at rest and during dobutamine stress. Methods: We applied a previously developed approach that combines non-invasive measurements with a physiologically-based, reduced-order model of the cardiovascular system to provide subject-specific estimates of parameters characterizing left ventricular function. In this model, the contractile state of the heart at each time point along the cardiac cycle is modeled using a time-varying elastance curve. Non-invasive data, including four-dimensional magnetic resonance imaging (4D Flow MRI) measurements, were acquired in nine subjects without a known heart disease at rest and during dobutamine stress. For each of the study subjects, we constructed two personalized models corresponding to the resting and the stress state. Results: Applying the modeling framework, we identified significant increases in the left ventricular contraction rate constant [from 1.5 ± 0.3 to 2 ± 0.5 (p = 0.038)] and relaxation constant [from 37.2 ± 6.9 to 46.1 ± 12 (p = 0.028)]. In addition, we found a significant decrease in the elastance diastolic time constant from 0.4 ± 0.04 s to 0.3 ± 0.03 s (p = 0.008). Conclusions: The integrated image-modeling approach allows the assessment of cardiovascular function given as model-based parameters. The agreement between the estimated parameter values and previously reported effects of dobutamine demonstrates the potential of the approach to assess advanced metrics of pathophysiology that are otherwise difficult to obtain non-invasively in clinical practice.
Collapse
Affiliation(s)
- Belén Casas
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Federica Viola
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Gunnar Cedersund
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Ann F Bolger
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Department of Medicine, University of California, San Francisco, San Francisco, CA, United States
| | - Matts Karlsson
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Division of Applied Thermodynamics and Fluid Mechanics, Department of Management and Engineering, Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
13
|
Bustamante M, Gupta V, Forsberg D, Carlhäll CJ, Engvall J, Ebbers T. Automated multi-atlas segmentation of cardiac 4D flow MRI. Med Image Anal 2018; 49:128-140. [DOI: 10.1016/j.media.2018.08.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Revised: 08/07/2018] [Accepted: 08/10/2018] [Indexed: 11/16/2022]
|
14
|
Callaghan FM, Bannon P, Barin E, Celemajer D, Jeremy R, Figtree G, Grieve SM. Age-related changes of shape and flow dynamics in healthy adult aortas: A 4D flow MRI study. J Magn Reson Imaging 2018; 49:90-100. [PMID: 30102443 DOI: 10.1002/jmri.26210] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Accepted: 05/17/2018] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Abnormal flow dynamics play an early and causative role in pathologic changes of the ascending aorta. PURPOSE To identify: 1) the changes in flow, shape, and size that occur in the ascending aorta with normal human ageing and 2) the influence of these factors on aortic flow dynamics. STUDY TYPE Retrospective. SUBJECTS In all, 247 subjects (age range 19-86 years, mean 49 ± 17.7, 169 males) free of aortic or aortic valve pathology were included in this study. Subjects were stratified by youngest (18-33 years; n = 64), highest (>60 years, n = 67), and the middle two quartiles (34-60 years, n = 116). FIELD STRENGTH/SEQUENCE Subjects underwent a cardiac MRI (3T) exam including 4D-flow MRI of the aorta. ASSESSMENT Aortic curvature, arch shape, ascending aortic angle, ascending aortic diameter, and the stroke volume normalized by the aortic volume (nSV) were measured. Velocity, vorticity, and helicity were quantified across the thoracic aorta. STATISTICAL TESTS Univariate and multivariate regressions were used to quantify continuous relationships between variables. RESULTS Aortic diameter, ascending aortic angle, shape, and curvature all increased across age while nSV decreased (all P < 0.0001). Systolic vorticity in the mid arch decreased by 50% across the age range (P < 0.0001), while peak helicity decreased by 80% (P < 0.0001). Curvature tightly governs optimal flow in the youngest quartile, with an effect size 1.5 to 4 times larger than other parameters in the descending aorta, but had a minimal influence with advancing age. In the upper quartile of age, flow dynamics were almost completely determined by nSV, exerting an effect size on velocity and vorticity >10 times that of diameter and other shape factors. DATA CONCLUSION Aortic shape influences flow dynamics in younger subjects. Flow conditions become increasingly disturbed with advancing age, and in these conditions nSV has a more dominant effect on flow patterns than shape factors. LEVEL OF EVIDENCE 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:90-100.
Collapse
Affiliation(s)
- Fraser M Callaghan
- Sydney Translational Imaging Laboratory, Heart Research Institute, Charles Perkins Centre, University of Sydney, Australia.,Sydney Medical School, University of Sydney, Camperdown, Australia
| | - Paul Bannon
- Sydney Medical School, University of Sydney, Camperdown, Australia.,Department of Cardiothoracic Surgery, Royal Prince Alfred Hospital, Camperdown, Australia.,Baird Institute, Sydney, Australia
| | - Edward Barin
- MQ Health Cardiology, Macquarie University Hospital, Macquarie Park, Australia
| | - David Celemajer
- Sydney Medical School, University of Sydney, Camperdown, Australia.,Department of Cardiology, Royal Prince Alfred Hospital, Camperdown, Australia
| | - Richmond Jeremy
- Sydney Medical School, University of Sydney, Camperdown, Australia.,Department of Cardiology, Royal Prince Alfred Hospital, Camperdown, Australia
| | - Gemma Figtree
- Sydney Medical School, University of Sydney, Camperdown, Australia.,Department of Cardiology, Royal North Shore Hospital, Camperdown, Australia
| | - Stuart M Grieve
- Sydney Translational Imaging Laboratory, Heart Research Institute, Charles Perkins Centre, University of Sydney, Australia.,Sydney Medical School, University of Sydney, Camperdown, Australia.,Department of Radiology, Royal Prince Alfred Hospital, Camperdown, Australia
| |
Collapse
|
15
|
Cibis M, Lindahl TL, Ebbers T, Karlsson LO, Carlhäll CJ. Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation. Front Physiol 2017; 8:1052. [PMID: 29311980 PMCID: PMC5732934 DOI: 10.3389/fphys.2017.01052] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Accepted: 11/30/2017] [Indexed: 12/31/2022] Open
Abstract
Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from the entire three-dimensional atrial volume throughout the cardiac cycle. We sought to investigate left atrial 4D blood flow patterns and hemostasis during left atrial stunning and after left atrial mechanical function was restored. Methods: 4D Flow and morphological CMR data as well as blood samples were collected in fourteen patients at two time-points: 2–3 h (Time-1) and 4 weeks (Time-2) following cardioversion. The volume of blood stasis and duration of blood stasis were calculated. In addition, hemostasis markers were analyzed. Results: From Time-1 to Time-2: Heart rate decreased (61 ± 7 vs. 56 ± 8 bpm, p = 0.01); Maximum change in left atrial volume increased (8 ± 4 vs. 22 ± 15%, p = 0.009); The duration of stasis (68 ± 11 vs. 57 ± 8%, p = 0.002) and the volume of stasis (14 ± 9 vs. 9 ± 7%, p = 0.04) decreased; Thrombin-antithrombin complex (TAT) decreased (5.2 ± 3.3 vs. 3.3 ± 2.2 μg/L, p = 0.008). A significant correlation was found between TAT and the volume of stasis (r2 = 0.69, p < 0.001) at Time-1 and between TAT and the duration of stasis (r2 = 0.34, p = 0.04) at Time-2. Conclusion: In this longitudinal study, left atrial multidimensional blood flow was altered and blood stasis was elevated during left atrial stunning compared to the restored left atrial mechanical function. The coagulability of blood was also elevated during atrial stunning. The association between blood stasis and hypercoagulability proposes that assessment of left atrial 4D flow can add to the pathophysiological understanding of thrombus formation during atrial fibrillation related atrial stunning.
Collapse
Affiliation(s)
- Merih Cibis
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden
| | - Tomas L Lindahl
- Division of Microbiology and Molecular Medicine, Department of Clinical and Experimental Medicine (IKE), Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden
| | - Lars O Karlsson
- Departments of Cardiology, Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.,Departments of Clinical Physiology, Medical and Health Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
16
|
Zajac J, Eriksson J, Alehagen U, Ebbers T, Bolger AF, Carlhäll CJ. Mechanical dyssynchrony alters left ventricular flow energetics in failing hearts with LBBB: a 4D flow CMR pilot study. Int J Cardiovasc Imaging 2017; 34:587-596. [PMID: 29098524 PMCID: PMC5859696 DOI: 10.1007/s10554-017-1261-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Accepted: 10/19/2017] [Indexed: 11/23/2022]
Abstract
The impact of left bundle branch block (LBBB) related mechanical dyssynchrony on left ventricular (LV) diastolic function remains unclear. 4D flow cardiovascular magnetic resonance (CMR) has provided reliable markers of LV dysfunction: reduced volume and kinetic energy (KE) of the portion of LV inflow which passes directly to outflow (Direct Flow) has been demonstrated in failing hearts compared to normal hearts. We sought to investigate the impact of mechanical dyssynchrony on diastolic function by comparing 4D flow in myopathic LVs with and without LBBB. CMR data were acquired at 3 T in 22 heart failure patients; 11 with LBBB and 11 without LBBB matched according to several demographic and clinical parameters. An established 4D flow analysis method was used to separate the LV end-diastolic (ED) volume into functional flow components based on the blood’s timing and route through the heart cavities. While the Direct Flow volume was not different between the groups, the KE possessed at ED was lower in LBBB patients (P = 0.018). Direct Flow entering the LV during early diastolic filling possessed less KE at ED in LBBB patients compared to non-LBBB patients, whereas no intergroup difference was observed during late filling. Pre-systolic KE of LV Direct Flow was reduced in patients with LBBB compared to matched patients with normal conduction. These intriguing findings propose that 4D flow specific measures can serve as markers of LV mechanical dyssynchrony in heart failure patients, and could possibly be investigated as predictors of response to cardiac resynchronization therapy.
Collapse
Affiliation(s)
- Jakub Zajac
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, 581 85, Linköping, Sweden. .,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden. .,Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Jonatan Eriksson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, 581 85, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Urban Alehagen
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, 581 85, Linköping, Sweden.,Department of Cardiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, 581 85, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Ann F Bolger
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, 581 85, Linköping, Sweden.,Department of Medicine, University of California San Francisco, San Francisco, CA, USA
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, 581 85, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
17
|
Casas B, Lantz J, Viola F, Cedersund G, Bolger AF, Carlhäll CJ, Karlsson M, Ebbers T. Bridging the gap between measurements and modelling: a cardiovascular functional avatar. Sci Rep 2017; 7:6214. [PMID: 28740184 PMCID: PMC5524911 DOI: 10.1038/s41598-017-06339-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2016] [Accepted: 06/12/2017] [Indexed: 11/08/2022] Open
Abstract
Lumped parameter models of the cardiovascular system have the potential to assist researchers and clinicians to better understand cardiovascular function. The value of such models increases when they are subject specific. However, most approaches to personalize lumped parameter models have thus far required invasive measurements or fall short of being subject specific due to a lack of the necessary clinical data. Here, we propose an approach to personalize parameters in a model of the heart and the systemic circulation using exclusively non-invasive measurements. The personalized model is created using flow data from four-dimensional magnetic resonance imaging and cuff pressure measurements in the brachial artery. We term this personalized model the cardiovascular avatar. In our proof-of-concept study, we evaluated the capability of the avatar to reproduce pressures and flows in a group of eight healthy subjects. Both quantitatively and qualitatively, the model-based results agreed well with the pressure and flow measurements obtained in vivo for each subject. This non-invasive and personalized approach can synthesize medical data into clinically relevant indicators of cardiovascular function, and estimate hemodynamic variables that cannot be assessed directly from clinical measurements.
Collapse
Affiliation(s)
- Belén Casas
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Jonas Lantz
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Federica Viola
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Gunnar Cedersund
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Ann F Bolger
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- Department of Medicine, University of California San Francisco, San Francisco, California, USA
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
- Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Matts Karlsson
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
- Division of Applied Thermodynamics and Fluid Mechanics, Department of Management and Engineering, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
| |
Collapse
|
18
|
Bustamante M, Gupta V, Carlhäll CJ, Ebbers T. Improving visualization of 4D flow cardiovascular magnetic resonance with four-dimensional angiographic data: generation of a 4D phase-contrast magnetic resonance CardioAngiography (4D PC-MRCA). J Cardiovasc Magn Reson 2017; 19:47. [PMID: 28645326 PMCID: PMC5481950 DOI: 10.1186/s12968-017-0360-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Accepted: 05/09/2017] [Indexed: 11/10/2022] Open
Abstract
Magnetic Resonance Angiography (MRA) and Phase-Contrast MRA (PC-MRA) approaches used for assessment of cardiovascular morphology typically result in data containing information from the entire cardiac cycle combined into one 2D or 3D image. Information specific to each timeframe of the cardiac cycle is, however, lost in this process. This study proposes a novel technique, called Phase-Contrast Magnetic Resonance CardioAngiography (4D PC-MRCA), that utilizes the full potential of 4D Flow CMR when generating temporally resolved PC-MRA data to improve visualization of the heart and major vessels throughout the cardiac cycle. Using non-rigid registration between the timeframes of the 4D Flow CMR acquisition, the technique concentrates information from the entire cardiac cycle into an angiographic dataset at one specific timeframe, taking movement over the cardiac cycle into account. Registration between the timeframes is used once more to generate a time-resolved angiography. The method was evaluated in ten healthy volunteers. Visual comparison of the 4D PC-MRCAs versus PC-MRAs generated from 4D Flow CMR using the traditional approach was performed by two observers using Maximum Intensity Projections (MIPs). The 4D PC-MRCAs resulted in better visibility of the main anatomical regions of the cardiovascular system, especially where cardiac or vessel motion was present. The proposed method represents an improvement over previous PC-MRA generation techniques that rely on 4D Flow CMR, as it effectively utilizes all the information available in the acquisition. The 4D PC-MRCA can be used to visualize the motion of the heart and major vessels throughout the entire cardiac cycle.
Collapse
Affiliation(s)
- Mariana Bustamante
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Vikas Gupta
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
19
|
Eriksson J, Zajac J, Alehagen U, Bolger AF, Ebbers T, Carlhäll CJ. Left ventricular hemodynamic forces as a marker of mechanical dyssynchrony in heart failure patients with left bundle branch block. Sci Rep 2017; 7:2971. [PMID: 28592851 PMCID: PMC5462838 DOI: 10.1038/s41598-017-03089-x] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Accepted: 04/21/2017] [Indexed: 11/12/2022] Open
Abstract
Left bundle branch block (LBBB) causes left ventricular (LV) dyssynchrony which is often associated with heart failure. A significant proportion of heart failure patients do not demonstrate clinical improvement despite cardiac resynchronization therapy (CRT). How LBBB-related effects on LV diastolic function may contribute to those therapeutic failures has not been clarified. We hypothesized that LV hemodynamic forces calculated from 4D flow MRI could serve as a marker of diastolic mechanical dyssynchrony in LBBB hearts. MRI data were acquired in heart failure patients with LBBB or matched patients without LBBB. LV pressure gradients were calculated from the Navier-Stokes equations. Integration of the pressure gradients over the LV volume rendered the hemodynamic forces. The findings demonstrate that the LV filling forces are more orthogonal to the main LV flow direction in heart failure patients with LBBB compared to those without LBBB during early but not late diastole. The greater the conduction abnormality the greater the discordance of LV filling force with the predominant LV flow direction (r2 = 0.49). Such unique flow-specific measures of mechanical dyssynchrony may serve as an additional tool for considering the risks imposed by conduction abnormalities in heart failure patients and prove to be useful in predicting response to CRT.
Collapse
Affiliation(s)
- Jonatan Eriksson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Jakub Zajac
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Urban Alehagen
- Department of Cardiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Ann F Bolger
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Department of Medicine, University of California, San Francisco, California, USA
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Division of Media and Information Technology, Department of Science and Technology/Swedish e-Science Research Centre (SeRC), Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden. .,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden. .,Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| |
Collapse
|
20
|
Deistung A, Schweser F, Reichenbach JR. Overview of quantitative susceptibility mapping. NMR IN BIOMEDICINE 2017; 30:e3569. [PMID: 27434134 DOI: 10.1002/nbm.3569] [Citation(s) in RCA: 184] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Revised: 05/03/2016] [Accepted: 05/09/2016] [Indexed: 06/06/2023]
Abstract
Magnetic susceptibility describes the magnetizability of a material to an applied magnetic field and represents an important parameter in the field of MRI. With the recently introduced method of quantitative susceptibility mapping (QSM) and its conceptual extension to susceptibility tensor imaging (STI), the non-invasive assessment of this important physical quantity has become possible with MRI. Both methods solve the ill-posed inverse problem to determine the magnetic susceptibility from local magnetic fields. Whilst QSM allows the extraction of the spatial distribution of the bulk magnetic susceptibility from a single measurement, STI enables the quantification of magnetic susceptibility anisotropy, but requires multiple measurements with different orientations of the object relative to the main static magnetic field. In this review, we briefly recapitulate the fundamental theoretical foundation of QSM and STI, as well as computational strategies for the characterization of magnetic susceptibility with MRI phase data. In the second part, we provide an overview of current methodological and clinical applications of QSM with a focus on brain imaging. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Andreas Deistung
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Jena, Germany
| | - Ferdinand Schweser
- Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, The State University of New York at Buffalo, NY, USA
- MRI Clinical and Translational Research Center, Jacobs School of Medicine and Biomedical Sciences, The State University of New York at Buffalo, NY, USA
| | - Jürgen R Reichenbach
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Jena, Germany
- Michael Stifel Center for Data-driven and Simulation Science Jena, Friedrich Schiller University Jena, Jena, Germany
| |
Collapse
|
21
|
Gupta V, Bustamante M, Fredriksson A, Carlhäll CJ, Ebbers T. Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis. Magn Reson Med 2017; 79:554-560. [PMID: 28303611 DOI: 10.1002/mrm.26674] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 02/06/2017] [Accepted: 02/17/2017] [Indexed: 11/08/2022]
Abstract
PURPOSE Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. METHOD The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. RESULTS High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). CONCLUSION Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Vikas Gupta
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Mariana Bustamante
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Alexandru Fredriksson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Physiology and Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
22
|
Cibis M, Bustamante M, Eriksson J, Carlhäll CJ, Ebbers T. Creating hemodynamic atlases of cardiac 4D flow MRI. J Magn Reson Imaging 2017; 46:1389-1399. [PMID: 28295788 PMCID: PMC5655727 DOI: 10.1002/jmri.25691] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 02/14/2017] [Indexed: 01/22/2023] Open
Abstract
Purpose Hemodynamic atlases can add to the pathophysiological understanding of cardiac diseases. This study proposes a method to create hemodynamic atlases using 4D Flow magnetic resonance imaging (MRI). The method is demonstrated for kinetic energy (KE) and helicity density (Hd). Materials and Methods Thirteen healthy subjects underwent 4D Flow MRI at 3T. Phase‐contrast magnetic resonance cardioangiographies (PC‐MRCAs) and an average heart were created and segmented. The PC‐MRCAs, KE, and Hd were nonrigidly registered to the average heart to create atlases. The method was compared with 1) rigid, 2) affine registration of the PC‐MRCAs, and 3) affine registration of segmentations. The peak and mean KE and Hd before and after registration were calculated to evaluate interpolation error due to nonrigid registration. Results The segmentations deformed using nonrigid registration overlapped (median: 92.3%) more than rigid (23.1%, P < 0.001), and affine registration of PC‐MRCAs (38.5%, P < 0.001) and affine registration of segmentations (61.5%, P < 0.001). The peak KE was 4.9 mJ using the proposed method and affine registration of segmentations (P = 0.91), 3.5 mJ using rigid registration (P < 0.001), and 4.2 mJ using affine registration of the PC‐MRCAs (P < 0.001). The mean KE was 1.1 mJ using the proposed method, 0.8 mJ using rigid registration (P < 0.001), 0.9 mJ using affine registration of the PC‐MRCAs (P < 0.001), and 1.0 mJ using affine registration of segmentations (P = 0.028). The interpolation error was 5.2 ± 2.6% at mid‐systole, 2.8 ± 3.8% at early diastole for peak KE; 9.6 ± 9.3% at mid‐systole, 4.0 ± 4.6% at early diastole, and 4.9 ± 4.6% at late diastole for peak Hd. The mean KE and Hd were not affected by interpolation. Conclusion Hemodynamic atlases can be obtained with minimal user interaction using nonrigid registration of 4D Flow MRI. Level of Evidence: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1389–1399.
Collapse
Affiliation(s)
- Merih Cibis
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Mariana Bustamante
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Jonatan Eriksson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Division of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
23
|
Eriksson J, Bolger AF, Ebbers T, Carlhäll CJ. Assessment of left ventricular hemodynamic forces in healthy subjects and patients with dilated cardiomyopathy using 4D flow MRI. Physiol Rep 2016; 4:4/3/e12685. [PMID: 26841965 PMCID: PMC4758930 DOI: 10.14814/phy2.12685] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
We hypothesized that the direction of global left ventricular (LV) hemodynamic forces during diastolic filling are concordant with the main flow axes in normal LVs, but that this pattern would be altered in dilated and dysfunctional LVs. Therefore, we aimed to assess the LV hemodynamic filling forces in a group of healthy subjects and compare them to the results from a group of patients with dilated cardiomyopathy (DCM). Ten healthy subjects and 10 DCM patients were enrolled. Morphological short‐ (SAx) and long‐axis (LAx) images and 4D flow MRI data were acquired at 1.5T. The LV pressure gradients were computed from the 4D flow data using the Navier–Stokes equations. By integrating the pressure gradients over the LV volume at each time frame, the magnitude and direction of the global hemodynamic force was calculated over the cardiac cycle. The hemodynamic forces acting in the SAx‐ and LAx‐directions were used to calculate the “SAx‐max/LAx‐max”‐ratio for the early (E‐wave) and late (A‐wave) diastolic filling. In the LAx‐plane, the temporal progression of the hemodynamic force followed a consistent pattern in the healthy subjects. The “SAx‐max/LAx‐max”‐ratio was significantly larger at both E‐wave (0.53 ± 0.15 vs. 0.23 ± 0.12, P < 0.0001) and A‐wave (0.44 ± 0.21 vs. 0.26 ± 0.09, P < 0.03) in the DCM patients compared to the healthy subjects. 4D flow MRI data allow quantification of LV hemodynamic forces acting on the LV myocardial wall. The LV hemodynamic filling forces showed a similar temporal progression among healthy subjects, whereas DCM patients had forces that were more heterogeneous in their direction and magnitude during diastole.
Collapse
Affiliation(s)
- Jonatan Eriksson
- Divsion of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Ann F Bolger
- Divsion of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden Department of Medicine, University of California, San Francisco, California
| | - Tino Ebbers
- Divsion of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden Division of Media and Information Technology, Department of Science and Technology/Swedish e-Science Research Centre (SeRC), Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Divsion of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
24
|
van der Geest RJ, Garg P. Advanced Analysis Techniques for Intra-cardiac Flow Evaluation from 4D Flow MRI. CURRENT RADIOLOGY REPORTS 2016; 4:38. [PMID: 27390626 PMCID: PMC4875115 DOI: 10.1007/s40134-016-0167-7] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
PURPOSE OF THE REVIEW Time-resolved 3D velocity-encoded MR imaging with velocity encoding in three directions (4D Flow) has emerged as a novel MR acquisition technique providing detailed information on flow in the cardiovascular system. In contrast to other clinically available imaging techniques such as echo-Doppler, 4D Flow MRI provides the 3D Flow velocity field within a volumetric region of interest over the cardiac cycle. This work reviews the most recent advances in the development and application of dedicated image analysis techniques for the assessment of intra-cardiac flow features from 4D Flow MRI. RECENT FINDINGS Novel image analysis techniques have been developed for extraction of relevant intra-cardiac flow features from 4D Flow MRI, which have been successfully applied in various patient cohorts and volunteer studies. Disturbed flow patterns have been linked with valvular abnormalities and ventricular dysfunction. Recent technical advances have resulted in reduced scan times and improvements in image quality, increasing the potential clinical applicability of 4D Flow MRI. SUMMARY 4D Flow MRI provides unique capabilities for 3D visualization and quantification of intra-cardiac blood flow. Contemporary knowledge on 4D Flow MRI shows promise for further exploration of the potential use of the technique in research and clinical applications.
Collapse
Affiliation(s)
- Rob J. van der Geest
- />Division of Image Processing, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands
| | - Pankaj Garg
- />Division of Biomedical Imaging, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, LS2 9JT UK
| |
Collapse
|
25
|
Bustamante M, Petersson S, Eriksson J, Alehagen U, Dyverfeldt P, Carlhäll CJ, Ebbers T. Atlas-based analysis of 4D flow CMR: automated vessel segmentation and flow quantification. J Cardiovasc Magn Reson 2015; 17:87. [PMID: 26438074 PMCID: PMC4595325 DOI: 10.1186/s12968-015-0190-5] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2015] [Accepted: 09/10/2015] [Indexed: 01/28/2023] Open
Abstract
BACKGROUND Flow volume quantification in the great thoracic vessels is used in the assessment of several cardiovascular diseases. Clinically, it is often based on semi-automatic segmentation of a vessel throughout the cardiac cycle in 2D cine phase-contrast Cardiovascular Magnetic Resonance (CMR) images. Three-dimensional (3D), time-resolved phase-contrast CMR with three-directional velocity encoding (4D flow CMR) permits assessment of net flow volumes and flow patterns retrospectively at any location in a time-resolved 3D volume. However, analysis of these datasets can be demanding. The aim of this study is to develop and evaluate a fully automatic method for segmentation and analysis of 4D flow CMR data of the great thoracic vessels. METHODS The proposed method utilizes atlas-based segmentation to segment the great thoracic vessels in systole, and registration between different time frames of the cardiac cycle in order to segment these vessels over time. Additionally, net flow volumes are calculated automatically at locations of interest. The method was applied on 4D flow CMR datasets obtained from 11 healthy volunteers and 10 patients with heart failure. Evaluation of the method was performed visually, and by comparison of net flow volumes in the ascending aorta obtained automatically (using the proposed method), and semi-automatically. Further evaluation was done by comparison of net flow volumes obtained automatically at different locations in the aorta, pulmonary artery, and caval veins. RESULTS Visual evaluation of the generated segmentations resulted in good outcomes for all the major vessels in all but one dataset. The comparison between automatically and semi-automatically obtained net flow volumes in the ascending aorta resulted in very high correlation (r (2)=0.926). Moreover, comparison of the net flow volumes obtained automatically in other vessel locations also produced high correlations where expected: pulmonary trunk vs. proximal ascending aorta (r (2)=0.955), pulmonary trunk vs. pulmonary branches (r (2)=0.808), and pulmonary trunk vs. caval veins (r (2)=0.906). CONCLUSIONS The proposed method allows for automatic analysis of 4D flow CMR data, including vessel segmentation, assessment of flow volumes at locations of interest, and 4D flow visualization. This constitutes an important step towards facilitating the clinical utility of 4D flow CMR.
Collapse
Affiliation(s)
- Mariana Bustamante
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
| | - Sven Petersson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Jonatan Eriksson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Urban Alehagen
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Department of Cardiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Petter Dyverfeldt
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
- Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
- Division of Media and Information Technology, Department of Science and Technology/Swedish e-Science Research Center (SeRC), Linköping University, Linköping, Sweden.
| |
Collapse
|
26
|
Loecher M, Schrauben E, Johnson KM, Wieben O. Phase unwrapping in 4D MR flow with a 4D single-step laplacian algorithm. J Magn Reson Imaging 2015; 43:833-42. [DOI: 10.1002/jmri.25045] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2015] [Revised: 08/22/2015] [Accepted: 08/24/2015] [Indexed: 11/06/2022] Open
Affiliation(s)
- Michael Loecher
- Department of Medical Physics; University of Wisconsin-Madison; Madison Wisconsin USA
| | - Eric Schrauben
- Department of Medical Physics; University of Wisconsin-Madison; Madison Wisconsin USA
| | - Kevin M. Johnson
- Department of Medical Physics; University of Wisconsin-Madison; Madison Wisconsin USA
| | - Oliver Wieben
- Department of Medical Physics; University of Wisconsin-Madison; Madison Wisconsin USA
- Department of Radiology; University of Wisconsin-Madison; Madison Wisconsin USA
| |
Collapse
|
27
|
Dyverfeldt P, Bissell M, Barker AJ, Bolger AF, Carlhäll CJ, Ebbers T, Francios CJ, Frydrychowicz A, Geiger J, Giese D, Hope MD, Kilner PJ, Kozerke S, Myerson S, Neubauer S, Wieben O, Markl M. 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson 2015; 17:72. [PMID: 26257141 PMCID: PMC4530492 DOI: 10.1186/s12968-015-0174-5] [Citation(s) in RCA: 548] [Impact Index Per Article: 60.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Accepted: 07/17/2015] [Indexed: 02/07/2023] Open
Abstract
Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 - 3×3×3 mm(3), typical temporal resolution of 30-40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations.
Collapse
Affiliation(s)
- Petter Dyverfeldt
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
| | - Malenka Bissell
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Alex J Barker
- Department of Radiology, Northwestern University, Chicago, USA.
| | - Ann F Bolger
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
- Department of Medicine, University of California San Francisco, San Francisco, CA, United States.
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
- Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
| | | | - Alex Frydrychowicz
- Klinik für Radiologie und Nuklearmedizin, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany.
| | - Julia Geiger
- Department of Radiology, University Children's Hospital Zurich, Zurich, Switzerland.
| | - Daniel Giese
- Department of Radiology, University Hospital of Cologne, Cologne, Germany.
| | - Michael D Hope
- Department of Radiology, University of California San Francisco, San Francisco, CA, United States.
| | - Philip J Kilner
- NIHR Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, National Heart and Lung Institute, Imperial College, London, UK.
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
| | - Saul Myerson
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, UK.
| | - Oliver Wieben
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
| | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, USA.
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, USA.
| |
Collapse
|
28
|
Nayak KS, Nielsen JF, Bernstein MA, Markl M, D Gatehouse P, M Botnar R, Saloner D, Lorenz C, Wen H, S Hu B, Epstein FH, N Oshinski J, Raman SV. Cardiovascular magnetic resonance phase contrast imaging. J Cardiovasc Magn Reson 2015; 17:71. [PMID: 26254979 PMCID: PMC4529988 DOI: 10.1186/s12968-015-0172-7] [Citation(s) in RCA: 154] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 07/16/2015] [Indexed: 11/10/2022] Open
Abstract
Cardiovascular magnetic resonance (CMR) phase contrast imaging has undergone a wide range of changes with the development and availability of improved calibration procedures, visualization tools, and analysis methods. This article provides a comprehensive review of the current state-of-the-art in CMR phase contrast imaging methodology, clinical applications including summaries of past clinical performance, and emerging research and clinical applications that utilize today's latest technology.
Collapse
Affiliation(s)
- Krishna S Nayak
- Ming Hsieh Department of Electrical Engineering, University of Southern California, 3740 McClintock Ave, EEB 406, Los Angeles, California, 90089-2564, USA.
| | - Jon-Fredrik Nielsen
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | | | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, IL, USA.
| | - Peter D Gatehouse
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, London, UK.
| | - Rene M Botnar
- Cardiovascular Imaging, Imaging Sciences Division, Kings's College London, London, UK.
| | - David Saloner
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
| | - Christine Lorenz
- Center for Applied Medical Imaging, Siemens Corporation, Baltimore, MD, USA.
| | - Han Wen
- Imaging Physics Laboratory, National Heart Lung and Blood Institute, Bethesda, MD, USA.
| | - Bob S Hu
- Palo Alto Medical Foundation, Palo Alto, CA, USA.
| | - Frederick H Epstein
- Departments of Radiology and Biomedical Engineering, University of Virginia, Charlottesville, VA, USA.
| | - John N Oshinski
- Departments of Radiology and Biomedical Engineering, Emory University School of Medicine, Atlanta, GA, USA.
| | - Subha V Raman
- Division of Cardiovascular Medicine, The Ohio State University, Columbus, OH, USA.
| |
Collapse
|
29
|
Goldstein G, Creath K. Quantitative phase microscopy: automated background leveling techniques and smart temporal phase unwrapping. APPLIED OPTICS 2015; 54:5175-5185. [PMID: 26192681 DOI: 10.1364/ao.54.005175] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
In order for time-dynamic quantitative phase microscopy to yield meaningful data to scientists, raw phase measurements must be converted to sequential time series that are consistently phase unwrapped with minimal residual background shape. Beyond the initial phase unwrapping, additional steps must be taken to convert the phase to time-meaningful data sequences. This consists of two major operations both outlined in this paper and shown to operate robustly on biological datasets. An automated background leveling procedure is introduced that consistently removes background shape and minimizes mean background phase value fluctuations. By creating a background phase value that is stable over time, the phase values of features of interest can be examined as a function of time to draw biologically meaningful conclusions. Residual differences between sequential frames of data can be present due to inconsistent phase unwrapping, causing localized regions to have phase values at similar object locations inconsistently changed by large values between frames, not corresponding to physical changes in the sample being observed. This is overcome by introducing a new method, referred to as smart temporal unwrapping that temporally unwraps and filters the phase data such that small motion between frames is accounted for and phase data are unwrapped consistently between frames. The combination of these methods results in the creation of phase data that is stable over time by minimizing errors introduced within the processing of the raw data.
Collapse
|
30
|
Eriksson J, Bolger AF, Carlhäll CJ, Ebbers T. Spatial heterogeneity of four-dimensional relative pressure fields in the human left ventricle. Magn Reson Med 2014; 74:1716-25. [PMID: 25427056 DOI: 10.1002/mrm.25539] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 10/13/2014] [Accepted: 10/27/2014] [Indexed: 11/10/2022]
Abstract
PURPOSE To assess the spatial heterogeneity of the four-dimensional (4D) relative pressure fields in the healthy human left ventricle (LV) and provide reference data for normal LV relative pressure. METHODS Twelve healthy subjects underwent a cardiac MRI examination where 4D flow and morphological data were acquired. The latter data were segmented and used to define the borders of the LV for computation of relative pressure fields using the pressure Poisson equation. The LV lumen was divided into 17 pie-shaped segments. RESULTS In the normal left ventricle, the relative pressure in the apical segments was significantly higher relative to the basal segments (P < 0.0005) along both the anteroseptal and inferolateral sides after the peaks of early (E-wave) and late (A-wave) diastolic filling. The basal anteroseptal segment showed significantly lower median pressure than the opposite basal inferolateral segment during both E-wave (P < 0.0005) and A-wave (P = 0.0024). CONCLUSION Relative pressure in the left ventricle is heterogeneous. During diastole, the main pressure differences in the LV occur along the basal-apical axis. However, pressure differences were also found in the short axis direction and may reflect important aspects of atrioventricular coupling. Additionally, this study provides reference data on LV pressure dynamics for a group of healthy subjects.
Collapse
Affiliation(s)
- Jonatan Eriksson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden
| | - Ann F Bolger
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Department of Medicine, University of California, San Francisco, California, USA
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.,Department of Clinical Physiology UHL, County Council of Östergötland, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.,Division of Media and Information Technology, Department of Science and Technology, Swedish e-Science Research Centre, Linköping University, Linköping, Sweden
| |
Collapse
|
31
|
Untenberger M, Hüllebrand M, Tautz L, Joseph AA, Voit D, Merboldt KD, Frahm J. Spatiotemporal phase unwrapping for real-time phase-contrast flow MRI. Magn Reson Med 2014; 74:964-70. [DOI: 10.1002/mrm.25471] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Revised: 08/29/2014] [Accepted: 09/01/2014] [Indexed: 11/06/2022]
Affiliation(s)
- Markus Untenberger
- Biomedizinische NMR Forschungs GmbH am Max-Planck Institut für biophysikalische Chemie; Göttingen Germany
| | - Markus Hüllebrand
- Fraunhofer MEVIS Institute for Medical Image Computing; Bremen Germany
| | - Lennart Tautz
- Fraunhofer MEVIS Institute for Medical Image Computing; Bremen Germany
| | - Arun A. Joseph
- Biomedizinische NMR Forschungs GmbH am Max-Planck Institut für biophysikalische Chemie; Göttingen Germany
- German Center for Cardiovascular Research (DZHK); Göttingen Germany
| | - Dirk Voit
- Biomedizinische NMR Forschungs GmbH am Max-Planck Institut für biophysikalische Chemie; Göttingen Germany
| | - K. Dietmar Merboldt
- Biomedizinische NMR Forschungs GmbH am Max-Planck Institut für biophysikalische Chemie; Göttingen Germany
| | - Jens Frahm
- Biomedizinische NMR Forschungs GmbH am Max-Planck Institut für biophysikalische Chemie; Göttingen Germany
- German Center for Cardiovascular Research (DZHK); Göttingen Germany
| |
Collapse
|
32
|
Goldstein G, Creath K. Quantitative Phase Microscopy: how to make phase data meaningful. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2014; 8949:89491C. [PMID: 25309099 DOI: 10.1117/12.2042103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
The continued development of hardware and associated image processing techniques for quantitative phase microscopy has allowed superior phase data to be acquired that readily shows dynamic optical volume changes and enables particle tracking. Recent efforts have focused on tying phase data and associated metrics to cell morphology. One challenge in measuring biological objects using interferometrically obtained phase information is achieving consistent phase unwrapping and -dimensions and correct for temporal discrepanices using a temporal unwrapping procedure. The residual background shape due to mean value fluctuations and residual tilts can be removed automatically using a simple object characterization algorithm. Once the phase data are processed consistently, it is then possible to characterize biological samples such as myocytes and myoblasts in terms of their size, texture and optical volume and track those features dynamically. By observing optical volume dynamically it is possible to determine the presence of objects such as vesicles within myoblasts even when they are co-located with other objects. Quantitative phase microscopy provides a label-free mechanism to characterize living cells and their morphology in dynamic environments, however it is critical to connect the measured phase to important biological function for this measurement modality to prove useful to a broader scientific community. In order to do so, results must be highly consistent and require little to no user manipulation to achieve high quality nynerical results that can be combined with other imaging modalities.
Collapse
Affiliation(s)
| | - Katherine Creath
- 4D Technology Corporation, Tucson AZ 85706 ; College of Optical Sciences, The University of Arizona, Tucson, AZ USA 85721 ; Optineering, Tucson, AZ USA 85719
| |
Collapse
|
33
|
Feng W, Neelavalli J, Haacke EM. Catalytic multiecho phase unwrapping scheme (CAMPUS) in multiecho gradient echo imaging: Removing phase wraps on a voxel-by-voxel basis. Magn Reson Med 2012; 70:117-26. [DOI: 10.1002/mrm.24457] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2012] [Revised: 07/04/2012] [Accepted: 07/17/2012] [Indexed: 12/22/2022]
|
34
|
Töger J, Carlsson M, Söderlind G, Arheden H, Heiberg E. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping. BMC Med Imaging 2011; 11:10. [PMID: 21486430 PMCID: PMC3102625 DOI: 10.1186/1471-2342-11-10] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2010] [Accepted: 04/12/2011] [Indexed: 11/29/2022] Open
Abstract
Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR) can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking complements and provides incremental information compared to particle tracing that may lead to a better understanding of blood flow and may improve diagnosis and prognosis of cardiovascular diseases.
Collapse
Affiliation(s)
- Johannes Töger
- Department of Clinical Physiology, Lund University, Skåne University Hospital Lund, Lund, Sweden
| | | | | | | | | |
Collapse
|
35
|
Johnson KM, Markl M. Improved SNR in phase contrast velocimetry with five-point balanced flow encoding. Magn Reson Med 2010; 63:349-55. [PMID: 20099326 DOI: 10.1002/mrm.22202] [Citation(s) in RCA: 105] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Phase contrast velocimetry can be utilized to measure complex flow for both quantitative and qualitative assessment of vascular hemodynamics. However, phase contrast requires that a maximum measurable velocity be set that balances noise and phase aliasing. To efficiently reduce noise in phase contrast images, several investigators have proposed extended velocity encoding schemes that use extra encodings to unwrap phase aliasing; however, existing techniques can lead to significant increases in echo and scan time, limiting their clinical benefits. In this work, we have developed a novel five-point velocity encoding scheme that efficiently reduces noise with minimal increases in scan and echo time. Investigations were performed in phantoms, demonstrating a 63% increase in velocity-to-noise ratio compared to standard four-point encoding schemes. Aortic velocity measurements were performed in healthy volunteers, showing similar velocity-to-noise ratio improvements. In those volunteers, it was also demonstrated that, without sacrificing accuracy, low-resolution images can be used for the fifth encoding point, reducing the scan time penalty from 25% down to less than 1%.
Collapse
Affiliation(s)
- Kevin M Johnson
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705-2275, USA.
| | | |
Collapse
|
36
|
Salfity MF, Huntley JM, Graves MJ, Marklund O, Cusack R, Beauregard DA. Extending the dynamic range of phase contrast magnetic resonance velocity imaging using advanced higher-dimensional phase unwrapping algorithms. J R Soc Interface 2009; 3:415-27. [PMID: 16849270 PMCID: PMC1578755 DOI: 10.1098/rsif.2005.0096] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Phase contrast magnetic resonance velocity imaging is a powerful technique for quantitative in vivo blood flow measurement. Current practice normally involves restricting the sensitivity of the technique so as to avoid the problem of the measured phase being 'wrapped' onto the range -pi to +pi. However, as a result, dynamic range and signal-to-noise ratio are sacrificed. Alternatively, the true phase values can be estimated by a phase unwrapping process which consists of adding integral multiples of 2pi to the measured wrapped phase values. In the presence of noise and data undersampling, the phase unwrapping problem becomes non-trivial. In this paper, we investigate the performance of three different phase unwrapping algorithms when applied to three-dimensional (two spatial axes and one time axis) phase contrast datasets. A simple one-dimensional temporal unwrapping algorithm, a more complex and robust three-dimensional unwrapping algorithm and a novel velocity encoding unwrapping algorithm which involves unwrapping along a fourth dimension (the 'velocity encoding' direction) are discussed, and results from the three are presented and compared. It is shown that compared to the traditional approach, both dynamic range and signal-to-noise ratio can be increased by a factor of up to five times, which demonstrates considerable promise for a possible eventual clinical implementation. The results are also of direct relevance to users of any other technique delivering time-varying two-dimensional phase images, such as dynamic speckle interferometry and synthetic aperture radar.
Collapse
Affiliation(s)
- M F Salfity
- Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Loughborough, UK.
| | | | | | | | | | | |
Collapse
|
37
|
Abstract
Field maps of the induced main magnetic field offset (DeltaB(0)) were measured in the rat heart at various points in the cardiac cycle for the purpose of identifying their effects on relaxation measurements. The mean DeltaB(0) of the left ventricle averaged across rats was found to be 0.11 +/- 0.35 ppm and 0.19 +/- 0.39 ppm at the onset of systole and diastole, respectively. The root mean square (RMS) variation in resonant frequency of the left ventricle averaged across rats was found to be 0.09 +/- 0.05 ppm and 0.06 +/- 0.04 ppm during systole and diastole, respectively. Temporal variations in DeltaB(0) could substantially affect quantitative MRI measurements. To assess this, transverse relaxation rates (R(2) and R(2)(*)) were measured at different points in the cardiac cycle, and the effects of DeltaB(0) were estimated using measured field map data. For a given region of the left ventricle, DeltaB(0) induced a mean error across rats of < or =3.9% for R(2) and < or =9.6% for R(2)(*). For R(2)(*) measurements, the static component of the field inhomogeneity was found to be responsible for most of the error induced.
Collapse
Affiliation(s)
- Richard D Dortch
- Department of Biomedical Engineering, Vanderbilt University School of Engineering, Nashville, Tennessee, USA
| | | |
Collapse
|
38
|
Markl M, Draney MT, Hope MD, Levin JM, Chan FP, Alley MT, Pelc NJ, Herfkens RJ. Time-Resolved 3-Dimensional Velocity Mapping in the Thoracic Aorta. J Comput Assist Tomogr 2004; 28:459-68. [PMID: 15232376 DOI: 10.1097/00004728-200407000-00005] [Citation(s) in RCA: 166] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVE An analysis of thoracic aortic blood flow in normal subjects and patients with aortic pathologic findings is presented. Various visualization tools were used to analyze blood flow patterns within a single 3-component velocity volumetric acquisition of the entire thoracic aorta METHODS Time-resolved, 3-dimensional phase-contrast magnetic resonance imaging (3D CINE PC MRI) was employed to obtain complete spatial and temporal coverage of the entire thoracic aorta combined with spatially registered 3-directional pulsatile blood flow velocities. Three-dimensional visualization tools, including time-resolved velocity vector fields reformatted to arbitrary 2-dimensional cut planes, 3D streamlines, and time-resolved 3D particle traces, were applied in a study with 10 normal volunteers. Results from 4 patient examinations with similar scan prescriptions to those of the volunteer scans are presented to illustrate flow features associated with common pathologic findings in the thoracic aorta. RESULTS Previously reported blood flow patterns in the thoracic aorta, including right-handed helical outflow, late systolic retrograde flow, and accelerated passage through the aortic valve plane, were visualized in all volunteers. The effects of thoracic aortic disease on spatial and temporal blood flow patterns are illustrated in clinical cases, including ascending aortic aneurysms, aortic regurgitation, and aortic dissection. CONCLUSION Time-resolved 3D velocity mapping was successfully applied in a study of 10 healthy volunteers and 4 patients with documented aortic pathologic findings and has proven to be a reliable tool for analysis and visualization of normal characteristic as well as pathologic flow features within the entire thoracic aorta.
Collapse
Affiliation(s)
- Michael Markl
- Department of Radiology, Stanford University, Stanford, CA 94304, USA.
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Chavez S, Xiang QS, An L. Understanding phase maps in MRI: a new cutline phase unwrapping method. IEEE TRANSACTIONS ON MEDICAL IMAGING 2002; 21:966-977. [PMID: 12472269 DOI: 10.1109/tmi.2002.803106] [Citation(s) in RCA: 81] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
This paper describes phase maps. A review of the phase unwrapping problem is given. Different structures, in particular fringelines, cutlines, and poles, contained within a phase map are described and their origin and behavior investigated. The problem of phase unwrapping can then be addressed with a better understanding of the source of poles or inconsistencies. This understanding, along with some assumptions about what is being encoded in the phase of a magnetic resonance image, are used to derive a new method for phase unwrapping which relies only on the phase map. The method detects cutlines and distinguishes between noise-induced poles and signal undersampling poles based on the length of the fringelines. The method was shown to be robust to noise and successful in unwrapping challenging clinical cases.
Collapse
Affiliation(s)
- Sofia Chavez
- Department of Physics and Astronomy, University of British Columbia, Vancouver, BC V6T IZI, Canada
| | | | | |
Collapse
|
40
|
Papaharilaou Y, Doorly DJ, Sherwin SJ. Assessing the accuracy of two-dimensional phase-contrast MRI measurements of complex unsteady flows. J Magn Reson Imaging 2001; 14:714-23. [PMID: 11747028 DOI: 10.1002/jmri.10008] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Two-dimensional phase-contrast MRI measurements of complex unsteady flows have been assessed for accuracy, together with procedures used to improve the precision of the measurements. Velocity measurements of single harmonic sinusoidal flow in a rigid bypass graft model with a fully three-dimensional geometry were compared to an accurate numerical solution of the Navier-Stokes equations for the same flow. Axial velocity profiles from the MRI were compared with the computational data, and instantaneous root mean square (rms) differences were calculated. Despite the complexity of the flow, with the aid of phase angle dynamic range extension, a spatially and temporally averaged rms error of between 7.8% and 11.5%, with respect to the spatially and temporally averaged velocity, was achieved. Spin saturation primarily and phase dispersion secondarily in complex transient recirculation zones were found to be significant contributors to overall error. Cross flow effects were also investigated but were of lesser significance. The result confirms the suitability of the technique for measuring complex unsteady flows.
Collapse
Affiliation(s)
- Y Papaharilaou
- Biomedical Flow Group, Aeronautics Department, Imperial College of Science, Technology and Medicine, London, UK
| | | | | |
Collapse
|
41
|
Herment A, Mousseaux E, Jolivet O, DeCesare A, Frouin F, Todd-Pokropek A, Bittoun J. Improved estimation of velocity and flow rate using regularized three-point phase-contrast velocimetry. Magn Reson Med 2000; 44:122-8. [PMID: 10893530 DOI: 10.1002/1522-2594(200007)44:1<122::aid-mrm18>3.0.co;2-c] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We improved the three-point phase-contrast method by regularization of MR velocity data after acquisition of a low velocity-to-noise ratio (VNR) velocity image and a high VNR aliased velocity image. The phase unwrapping algorithm is based on the assumed correlation of the velocity of adjacent flow voxels on the low VNR and the unaliased high VNR images. We used Fourier encoding with eight velocity-encoding gradient steps to obtain reference velocity images of the aorta from five subjects (274 images) and compared them with the phase-contrast and three-point phase-contrast images with and without regularization. The VNR of the regularized velocity image was improved by 9.1 dB and the VNR of the three-point phase-contrast velocity image was improved by 0.7 dB with respect to the low first moment velocity image. Corresponding improvements of 9 dB and 3.7 dB were obtained for the estimations of instantaneous flow rate. Magn Reson Med 44:122-128, 2000.
Collapse
Affiliation(s)
- A Herment
- INSERM U.494 CHU Pitié, Paris, France.
| | | | | | | | | | | | | |
Collapse
|
42
|
Herment A, Mousseaux E, De Cesare A, Jolivet O, Dumée P, Todd-Pokropek A, Bittoun J. Spatial regularization of flow patterns in magnetic resonance velocity mapping. J Magn Reson Imaging 1999; 10:851-60. [PMID: 10548799 DOI: 10.1002/(sici)1522-2586(199911)10:5<851::aid-jmri34>3.0.co;2-i] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
A technique dedicated to spatial regularization of magnetic resonance (MR) velocity data has been implemented to improve flow image quality. It is assumed that neighboring flow-velocity pixels are partially correlated, although large-velocity discontinuities remain possible. Increasing MR signal magnitude due to the in-flow effect also is used to enhance further reliability of the estimated velocity. By using an eight-step Fourier-encoding approach, 162 "reference" velocity images acquired in the ascending aorta from six healthy volunteers were compared with "raw" and "regularized" images that were computed from only two gradient steps. The mean square error decreased from 0.12 m(2) x s(-2) to 0.06 m(2) x s(-2) (P < 10-9) for velocity pixel values and from 1929 ml(2) x s(-2) to 1336 ml(2) x s(-2) (P < 0.01) for instantaneous flow rates. The regularization of two-step data sets provides the same velocity image quality as that found after using three-step data sets without regularization. The method can be applied to phase-velocity data sets of any MR technique to reduce velocity noise. J. Magn. Reson. Imaging 1999;10:851-860.
Collapse
Affiliation(s)
- A Herment
- INSERM U 494, CHU Pitié, 75013 Paris, France.
| | | | | | | | | | | | | |
Collapse
|
43
|
Wigström L, Ebbers T, Fyrenius A, Karlsson M, Engvall J, Wranne B, Bolger AF. Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI. Magn Reson Med 1999; 41:793-9. [PMID: 10332856 DOI: 10.1002/(sici)1522-2594(199904)41:4<793::aid-mrm19>3.0.co;2-2] [Citation(s) in RCA: 146] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The flow patterns in the human heart are complex and difficult to visualize using conventional two-dimensional (2D) modalities, whether they depict a single velocity component (Doppler echocardiography) or all three components in a few slices (2D phase contrast MRI). To avoid these shortcomings, a temporally resolved 3D phase contrast technique was used to derive data describing the intracardiac velocity fields in normal volunteers. The MRI data were corrected for phase shifts caused by eddy currents and concomitant gradient fields, with improvement in the accuracy of subsequent flow visualizations. Pathlines describing the blood pathways through the heart were generated from the temporally resolved velocity data, starting from user-specified locations and time frames. Flow trajectories were displayed as 3D particle traces, with simultaneous demonstration of morphologic 2D slices. This type of visualization is intuitive and interactive and may extend our understanding of dynamic and previously unrecognized patterns of intracardiac flow.
Collapse
Affiliation(s)
- L Wigström
- Department of Clinical Physiology, Linköping University, Sweden.
| | | | | | | | | | | | | |
Collapse
|
44
|
Wigstr�m L, Ebbers T, Fyrenius A, Karlsson M, Engvall J, Wranne B, Bolger AF. Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI. Magn Reson Med 1999. [DOI: 10.1002/(sici)1522-2594(199904)41:4%3c793::aid-mrm19%3e3.0.co;2-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
|