1
|
Fink E, Gartshein E, Khinast JG. Extending the Use of Optical Coherence Tomography to Scattering Coatings Containing Pigments. J Pharm Sci 2024; 113:1580-1585. [PMID: 38246362 DOI: 10.1016/j.xphs.2024.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 01/15/2024] [Accepted: 01/15/2024] [Indexed: 01/23/2024]
Abstract
Coating thickness is a critical quality attribute of many coated tablets. Functional coatings ensure correct drug release kinetics or protection from light, while non-functional coatings are generally applied for cosmetic reasons. Traditionally, coating thickness is assessed indirectly via offline methods, such as weight gain or diameter growth. In the past decade, several methods, including optical coherence tomography (OCT) and Raman spectroscopy, have emerged to perform in-line measurements of various subclasses of coating formulations. However, there are some obstacles. For example, when using OCT, a major challenge is scattering pigments, such as titanium dioxide and iron oxide, which make the interface between the coating and the tablet core difficult to detect. This work explores novel OCT image evaluation techniques using unsupervised machine learning to compute image metrics. Certain image metrics of highly scattering coatings are correlated with the tablet thickness, and hence indirectly with the coating thickness. The method was demonstrated using a titanium dioxide rich coating formulation. The results are expected to be applicable to other scattering coatings and will significantly broaden the applicability of OCT to at-line and in-line coating thickness measurements of a much larger class of coating formulations.
Collapse
Affiliation(s)
- Elisabeth Fink
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.
| | - Elen Gartshein
- Pfizer Inc, 100 Rt 206N, Gladstone Peapack, NJ 07977, USA
| | - Johannes G Khinast
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13, 8010 Graz, Austria
| |
Collapse
|
2
|
Sivanesapillai R, Ehrig A, Nogueira LW, Vukosavljevic B, Grilc B, Ilić IG, Bharadwaj R, Sibanc R. A validation of discrete-element model simulations for predicting tablet coating variability. Int J Pharm 2023:123109. [PMID: 37295569 DOI: 10.1016/j.ijpharm.2023.123109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 06/03/2023] [Accepted: 06/05/2023] [Indexed: 06/12/2023]
Abstract
Achieving an even coating distribution on tablets during the coating process can be challenging, not to mention the challenges of accurately measuring and quantifying inter-tablet coating variability. Computer simulations using the Discrete Element Method (DEM) provide a viable pathway towards model-predictive design of coating processes. The purpose of this study was to assess their predictivity accounting for both experimental and simulation input uncertainties. To this end, a comprehensive set of coating experiments covering various process scales, process conditions and tablet shapes were conducted. A water-soluble formulation was developed to enable rapid spectroscopic UV/VIS analysis of coating amounts on a large number of tablets. DEM predictions are found to lie within the experimentally inferred confidence intervals in all cases. A mean absolute comparison error of 0.54 % was found between model predictions of coating variability and respective sample point estimates. Among all simulation inputs the parameterization of spray area sizes is considered the most significant source for prediction errors. However, this error was found significantly smaller in magnitude compared to experimental uncertainties at larger process scales underlining the value of DEM in the design of industrial coating processes.
Collapse
Affiliation(s)
| | - Anja Ehrig
- Bayer AG, Engineering and Technology, Leverkusen, 51368, Germany
| | | | | | - Blaž Grilc
- University of Ljubljana, Faculty of Pharmacy, Department of Pharmaceutical Technology, Ljubljana, 1000, Slovenia
| | - Ilija German Ilić
- University of Ljubljana, Faculty of Pharmacy, Department of Pharmaceutical Technology, Ljubljana, 1000, Slovenia
| | | | - Rok Sibanc
- Bayer AG, Chemical and Pharmaceutical Development, Wuppertal, 42117, Germany.
| |
Collapse
|
3
|
Vijayakumar J, Goudarzi NM, Eeckhaut G, Schrijnemakers K, Cnudde V, Boone MN. Characterization of Pharmaceutical Tablets by X-ray Tomography. Pharmaceuticals (Basel) 2023; 16:ph16050733. [PMID: 37242516 DOI: 10.3390/ph16050733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/07/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023] Open
Abstract
Solid dosage forms such as tablets are extensively used in drug administration for their simplicity and large-scale manufacturing capabilities. High-resolution X-ray tomography is one of the most valuable non-destructive techniques to investigate the internal structure of the tablets for drug product development as well as for a cost effective production process. In this work, we review the recent developments in high-resolution X-ray microtomography and its application towards different tablet characterizations. The increased availability of powerful laboratory instrumentation, as well as the advent of high brilliance and coherent 3rd generation synchrotron light sources, combined with advanced data processing techniques, are driving the application of X-ray microtomography forward as an indispensable tool in the pharmaceutical industry.
Collapse
Affiliation(s)
- Jaianth Vijayakumar
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| | - Niloofar Moazami Goudarzi
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| | - Guy Eeckhaut
- Janssen Pharmaceutica, Turnhoutseweg 30, 2340 Beerse, Belgium
| | | | - Veerle Cnudde
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Pore-Scale Processes in Geomaterials Research (PProGRess), Department of Geology, Ghent University, Krijgslaan 281/S8, 9000 Gent, Belgium
- Environmental Hydrogeology, Department of Earth Sciences, Faculty of Geosciences, Utrecht University, Princetonlaan 8A, 3584 CD Utrecht, The Netherlands
| | - Matthieu N Boone
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| |
Collapse
|
4
|
Gu J, Qin J, Han Z. Relative humidity sensing using THz metasurfaces combined with polyvinyl alcohol. APPLIED OPTICS 2022; 61:6086-6091. [PMID: 36255850 DOI: 10.1364/ao.463276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Accepted: 06/17/2022] [Indexed: 06/16/2023]
Abstract
Relative humidity (RH) plays an important role in almost every industrial field. Thus, the detection of RH is of great significance in these fields. Terahertz (THz) waves are extremely sensitive to the changes in RH because water absorbs strongly in this electromagnetic band. In this paper, a RH sensor based on THz metasurfaces combined with polyvinyl alcohol (PVA) is proposed. Different from the conventional metasurface sensor, our sensor includes a PVA layer that is sandwiched between the metal structure and the substrate. The improved design is able to enhance the interaction between the electric field and the water molecules absorbed in the PVA layer, and the sensitivity of the humidity sensor can reach 0.34 GHz/%RH, which is more than twice that of the conventional metasurface sensor. These results show that the proposed sensor can be used for the detection of RH with high reliability and high sensitivity, which open a new, to the best of our knowledge, avenue for RH sensing using THz spectroscopy.
Collapse
|
5
|
Wang B, Qin X, Li W, Li Z, Zhu L. Learned iterative shrinkage and thresholding algorithm for terahertz sparse deconvolution. OPTICS EXPRESS 2022; 30:18238-18249. [PMID: 36221629 DOI: 10.1364/oe.456688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 05/02/2022] [Indexed: 06/16/2023]
Abstract
Terahertz sparse deconvolution based on an iterative shrinkage and thresholding algorithm (ISTA) has been used to characterize multilayered structures with resolution equivalent to or finer than the sampling period of the measurement. However, this method was only studied on thin samples to separate the overlapped echos that can't be distinguished by other deconvolution algorithms. Besides, ISTA heavily depends on the convolution matrix consisting of delayed incident pulse, which is difficult to precisely extricate from the reference signal, and thereby fluctuations caused by noise are occasionally treated as echos. In this work, a terahertz sparse deconvolution based on a learned iterative shrinkage and thresholding algorithm (LISTA) is proposed. The method enclosed the matrix multiplication and soft thresholding in a block and cascaded multiple blocks together to form a deep network. The convolution matrices of the network were updated by stochastic gradient descent to minimize the distance between the output sparse vector and the optimal sparse representation of the signal, and subsequently the trained network made more precise estimation of the echos than ISTA. Additionally, LISTA is notably faster than ISTA, which is important for real-time tomographic-image processing. The algorithm was evaluated on terahertz tomographic imaging of a high-density poly ethylene (HDPE) sample, revealing obvious improvements in detecting defects of different sizes and depths. This technique has potential usage in nondestructive testings of thick samples, where echos reflected by minor defects are not discernible by existed deconvolution algorithms.
Collapse
|
6
|
Polymers in pharmaceutical additive manufacturing: A balancing act between printability and product performance. Adv Drug Deliv Rev 2021; 177:113923. [PMID: 34390775 DOI: 10.1016/j.addr.2021.113923] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Revised: 07/08/2021] [Accepted: 08/09/2021] [Indexed: 12/19/2022]
Abstract
Materials and manufacturing processes share a common purpose of enabling the pharmaceutical product to perform as intended. This review on the role of polymeric materials in additive manufacturing of oral dosage forms, focuses on the interface between the polymer and key stages of the additive manufacturing process, which determine printability. By systematically clarifying and comparing polymer functional roles and properties for a variety of AM technologies, together with current and emerging techniques to characterize these properties, suggestions are provided to stimulate the use of readily available and sometimes underutilized pharmaceutical polymers in additive manufacturing. We point to emerging characterization techniques and digital tools, which can be harnessed to manage existing trade-offs between the role of polymers in printer compatibility versus product performance. In a rapidly evolving technological space, this serves to trigger the continued development of 3D printers to suit a broader variety of polymers for widespread applications of pharmaceutical additive manufacturing.
Collapse
|
7
|
Mondal K, Nuñez L, Downey CM, van Rooyen IJ. Thermal Barrier Coatings Overview: Design, Manufacturing, and Applications in High-Temperature Industries. Ind Eng Chem Res 2021. [DOI: 10.1021/acs.iecr.1c00788] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Kunal Mondal
- Materials Science and Engineering Department, Idaho National Laboratory, Idaho Falls, Idaho 83415, United States
| | - Luis Nuñez
- Irradiated Fuels and Materials Department, Idaho National Laboratory, Idaho Falls, Idaho 83415, United States
| | - Calvin M. Downey
- Experiment Design Department, Idaho National Laboratory, Idaho Falls, Idaho 83415, United States
| | - Isabella J. van Rooyen
- Reactor System Design and Analysis Division, Idaho National Laboratory, Idaho Falls, Idaho 83415, United States
| |
Collapse
|
8
|
Applications of machine vision in pharmaceutical technology: A review. Eur J Pharm Sci 2021; 159:105717. [DOI: 10.1016/j.ejps.2021.105717] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 01/08/2021] [Accepted: 01/11/2021] [Indexed: 02/07/2023]
|
9
|
Xie C, You Y, Ma H, Zhao Y. Mechanism of inter-tablet coating variability: Investigation about the motion behavior of ellipsoidal tablets in a pan coater. POWDER TECHNOL 2021. [DOI: 10.1016/j.powtec.2020.10.088] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
10
|
Sacher S, Peter A, Khinast JG. Feasibility of In-line monitoring of critical coating quality attributes via OCT: Thickness, variability, film homogeneity and roughness. INTERNATIONAL JOURNAL OF PHARMACEUTICS-X 2021; 3:100067. [PMID: 33385160 PMCID: PMC7772539 DOI: 10.1016/j.ijpx.2020.100067] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 12/10/2020] [Accepted: 12/11/2020] [Indexed: 11/16/2022]
Abstract
The feasibility of Optical Coherence Tomography (OCT) for in-line monitoring of pharmaceutical film coating processes has recently been demonstrated. OCT enables real-time acquisition of high-resolution cross-sectional images of coating layers and computation of coating thickness. In addition, coating quality attributes can be computed based on in-line data. This study assesses the in-line applicability of OCT to various coating functionalities and formulations. Several types of commercial film-coated tablets containing the most common ingredients were investigated. To that end, the tablets were placed into a miniaturized perforated drum. An in-line OCT system was used to monitor the tablet bed. This set-up resembles the final stage of an industrial pan coating process. All investigated coatings were measured, and the coating thickness, homogeneity and roughness were computed. The rotation rate was varied in a range comparable to large-scale coating operations, and no influence on the outcome was observed. The results indicate that OCT can be used to determine end-point and establish in-process control for a wide range of coating formulations. The real-time computation of coating homogeneity and roughness can support process optimization and formulation development.
Collapse
Affiliation(s)
- Stephan Sacher
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13/2, 8010Graz, Austria
| | - Anna Peter
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13/2, 8010Graz, Austria
| | - Johannes G Khinast
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13/2, 8010Graz, Austria.,Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13/3, 8010 Graz, Austria
| |
Collapse
|
11
|
Wolfgang M, Weißensteiner M, Clarke P, Hsiao WK, Khinast JG. Deep convolutional neural networks: Outperforming established algorithms in the evaluation of industrial optical coherence tomography (OCT) images of pharmaceutical coatings. Int J Pharm X 2020; 2:100058. [PMID: 33294841 PMCID: PMC7689324 DOI: 10.1016/j.ijpx.2020.100058] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
This paper presents a novel evaluation approach for optical coherence tomography (OCT) image analysis of pharmaceutical solid dosage forms based on deep convolutional neural networks (CNNs). As a proof of concept, CNNs were applied to image data from both, in- and at-line OCT implementations, monitoring film-coated tablets as well as single- and multi-layered pellets. CNN results were compared against results from established algorithms based on ellipse-fitting, as well as to human-annotated ground truth data. Performance benchmarks used include, efficiency (computation speed), sensitivity (number of detections from a defined test set) and accuracy (deviation from the reference method). The results were validated by comparing the output of several algorithms to data manually annotated by human experts and microscopy images of cross-sectional cuts of the same dosage forms as a reference method. In order to guarantee comparability for all results, the algorithms were executed on the same hardware. Since modern OCT systems must operate under real-time conditions in order to be implemented in-line into manufacturing lines, the necessary steps are discussed on how to achieve this goal without sacrificing the algorithmic performance and how to tailor a deep CNN to cope with the high amount of image noise and alterations in object appearance. The developed deep learning approach outperforms static algorithms currently available in pharma applications with respect to performance benchmarks, and represents the next level in real time evaluation of challenging industrial OCT image data.
Collapse
Affiliation(s)
| | | | - Phillip Clarke
- Research Center Pharmaceutical Engineering GmbH, Graz, Austria
| | - Wen-Kai Hsiao
- Research Center Pharmaceutical Engineering GmbH, Graz, Austria
| | - Johannes G. Khinast
- Research Center Pharmaceutical Engineering GmbH, Graz, Austria
- Institute for Process and Particle Engineering, Graz University of Technology, Graz, Austria
| |
Collapse
|
12
|
Kamińska AM, Strąkowski MR, Pluciński J. Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements. SENSORS 2020; 20:s20195653. [PMID: 33023212 PMCID: PMC7582414 DOI: 10.3390/s20195653] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 09/18/2020] [Accepted: 09/25/2020] [Indexed: 11/16/2022]
Abstract
The main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has been expressed as a multiple beam interference. Therefore, the OCT system was modeled as a two-beam interferometer (e.g., Michelson), in which one beam propagates from the reference arm and the other comes from a Fabry-Pérot interferometer. As a consequence, the mathematical model consists of the main Michelson interferometer, in which the measuring arm represents the Fabry-Pérot interferometer. The parameters of the layer (or foil) are evaluated by analyzing the minimum value of the interference contrast. The model developed predicts the behavior of the thin layers made from different materials (with different refractive indexes) with different thickness and located at different depths. To verify the correctness of the proposed model, an experiment with a wedge cell has been carried out. The wedge cell was shifted across the scanning beam using a linear translation stage with a micrometer screw under the scanning head. The relationship between the thickness of the gap of the wedge cell and the OCT output signal is presented. For the additional verification of the proposed model, the results of the measurements of the thickness of the thin foil were compared with the theoretical results of the simulations. The film thickness was evaluated based on the calculated positions of the minimum value of interference contrast. A combination of the standard potentialities of OCT with the proposed approach to analyzing the signal produces new metrological possibilities. The method developed allows us to evaluate thickness under the resolution of the system and the location of the layer as well. This produces the possibility of measuring a layer which is covered by another layer. Moreover, it is possible to create a thickness map with high sensitivity to thickness changes. These experiments and simulations are the culmination of preliminary research for evaluating the potential of the proposed measurement method.
Collapse
|
13
|
Non-intrusive high resolution in-vitro measurement of regional drug powder deposition. Int J Pharm 2020; 582:119286. [PMID: 32278719 DOI: 10.1016/j.ijpharm.2020.119286] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 03/07/2020] [Accepted: 03/27/2020] [Indexed: 01/15/2023]
Abstract
Optical Coherence Tomography (OCT) is a high-resolution and non-invasive cross-sectional imaging technique mainly used for medical imaging and industrial non-destructive testing. However, its feasibility in the quantification of pulmonary drug deposition has not been investigated. In this study, an optically accessible airway model of the upper airway and the tracheobronchial tree was used, and experiments were performed at flow rates of 40 L/min, 60 L/min and 80 L/min. Drug deposition in different regions of the airway cast has been determined and quantified from OCT images of the deposition layer. Regionally resolved measurement of deposition shows that flow rate has a significant effect (p = 0.04) on the average thickness of the deposition layer in the upper airway but not in the tracheobronchial tree under these test conditions. These localized and high-resolution measurements of deposition also demonstrate that the flow rate can influence the spatial uniformity of the deposition layer. The technique is able to provide significant regional drug deposition details, including the thickness, spatial deposition pattern and micro-cavities in the deposition layer, that would potentially serve to assess the efficacy of inhalation drug delivery systems.
Collapse
|
14
|
Alves-Lima D, Song J, Li X, Portieri A, Shen Y, Zeitler JA, Lin H. Review of Terahertz Pulsed Imaging for Pharmaceutical Film Coating Analysis. SENSORS 2020; 20:s20051441. [PMID: 32155785 PMCID: PMC7085697 DOI: 10.3390/s20051441] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 02/27/2020] [Accepted: 03/02/2020] [Indexed: 12/02/2022]
Abstract
Terahertz pulsed imaging (TPI) was introduced approximately fifteen years ago and has attracted a lot of interest in the pharmaceutical industry as a fast, non-destructive modality for quantifying film coatings on pharmaceutical dosage forms. In this topical review, we look back at the use of TPI for analysing pharmaceutical film coatings, highlighting the main contributions made and outlining the key challenges ahead.
Collapse
Affiliation(s)
- Décio Alves-Lima
- Department of Engineering, Lancaster University, Lancaster LA1 4YW, UK; (D.A.-L.); (J.S.); (X.L.)
| | - Jun Song
- Department of Engineering, Lancaster University, Lancaster LA1 4YW, UK; (D.A.-L.); (J.S.); (X.L.)
- Department of Information Science, Nanjing Forestry University, Nanjing 210037, Jiangsu, China
| | - Xiaoran Li
- Department of Engineering, Lancaster University, Lancaster LA1 4YW, UK; (D.A.-L.); (J.S.); (X.L.)
| | - Alessia Portieri
- TeraView Ltd., 1, Enterprise Cambridge Research Park, Cambridge CB25 9PD, UK;
| | - Yaochun Shen
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ, UK;
| | - J. Axel Zeitler
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge CB3 0AS, UK;
| | - Hungyen Lin
- Department of Engineering, Lancaster University, Lancaster LA1 4YW, UK; (D.A.-L.); (J.S.); (X.L.)
- Correspondence:
| |
Collapse
|
15
|
Mohan S, Odani N, Hossain MN, Feng H, Li Y, Kato E, Drennen JK, Anderson CA. Terahertz Time of Flight Spectroscopy as a Coating Thickness Reference Method for Partial Least Squares Near Infrared Spectroscopy Models. Anal Chem 2020; 92:3658-3665. [PMID: 32020798 DOI: 10.1021/acs.analchem.9b04750] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Near infrared spectroscopy (NIRS) is often used during the tablet coating process to assess coating thickness. As the coating process proceeds, the increase and decrease in NIRS signal from both the coating formulation and tablet core has been related to coating thickness. Partial least-squares models are often generated relating NIRS spectra to reference coating thickness measurements for in-line and/or at-line monitoring of the coating process. This study investigated the effect of the reference coating thickness measurements on the accuracy of the model. The two primary reference techniques used were weight gain-based coating thickness and terahertz-based coating thickness. Most NIRS coating thickness models currently use weight gain-based reference values; however, terahertz-time-of-flight spectroscopy (THz-TOF) offers a more direct reference coating thickness measurement. Results showed that the accuracy of the NIRS coating thickness model significantly improved when terahertz-based coating thickness measurements were used as reference when compared to weight gain-based coating thickness measurements. Therefore, the application of THz-TOF as a reference method is further demonstrated.
Collapse
Affiliation(s)
- Shikhar Mohan
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania 15282, United States.,Duquesne University, Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| | - Noritaka Odani
- Manufacturing Technology Department, Towa Pharmaceutical Co., Ltd., Ichiban-cho, Kadoma, Osaka 571-0033, Japan
| | - Md Nayeem Hossain
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania 15282, United States.,Duquesne University, Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| | - Hanzhou Feng
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania 15282, United States.,Duquesne University, Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| | - Yi Li
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania 15282, United States.,Duquesne University, Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| | - Eiji Kato
- New Concept Product Initiative, Advantest Corporation, Sendai 989-3124 Japan
| | - James K Drennen
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania 15282, United States.,Duquesne University, Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| | - Carl A Anderson
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, Pennsylvania 15282, United States.,Duquesne University, Graduate School for Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| |
Collapse
|
16
|
At-line validation of optical coherence tomography as in-line/at-line coating thickness measurement method. Int J Pharm 2019; 572:118766. [DOI: 10.1016/j.ijpharm.2019.118766] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 10/01/2019] [Accepted: 10/03/2019] [Indexed: 11/19/2022]
|
17
|
Odani N, Mohan S, Kato E, Feng H, Li Y, Hossain MN, Drennen JK, Anderson CA. Determining the effect of photodegradation on film coated nifedipine tablets with terahertz based coating thickness measurements. Eur J Pharm Biopharm 2019; 145:35-41. [PMID: 31568821 DOI: 10.1016/j.ejpb.2019.09.024] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/02/2019] [Accepted: 09/26/2019] [Indexed: 11/17/2022]
Abstract
Film coating of nifedipine tablets is commonly performed to reduce photo-degradation. The coating thickness of these tablets is a primary dictating factor of photo-stability. Terahertz spectroscopy enables accurate measurement of coating thickness. This study identifies a method to determine an end-point of a photo-protective coating process by using coating thickness measurements from terahertz time of flight spectroscopy (THz-TOF). For this method, nifedipine tablets, at different coating thicknesses, were placed in a photostability chamber. The illumination conditions of the coated tablets were adjusted based on the time duration of these tablets inside the chamber. A multiple linear regression model was developed with the coating thickness estimates from THz-TOF and illumination conditions information to predict the amount of drug remaining after photo-degradation (percent label claim). The prediction error of this model was 1.03% label claim in the range of 88.4-100.6% label claim. According to this model, acceptable levels of photo-protection in illumination conditions of up to approximately 700,000 lx hours was achieved at the end of the coating process (approximately 50 µm coating thickness) performed in this study. These results suggest THz-TOF as a viable process analytical technology tool for process understanding and end-point determination of a photo-protective coating process.
Collapse
Affiliation(s)
- Noritaka Odani
- Manufacturing Technology Department, Towa Pharmaceutical CO., LTD, Ichiban-cho, Kadoma, Osaka 571-0033, Japan
| | - Shikhar Mohan
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States; Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States
| | - Eiji Kato
- New Concept Product Initiative, Advantest Corporation, Sendai 989-3124, Japan
| | - Hanzhou Feng
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States; Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States
| | - Yi Li
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States; Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States
| | - Md Nayeem Hossain
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States; Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States
| | - James K Drennen
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States; Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States
| | - Carl A Anderson
- Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States; Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States.
| |
Collapse
|
18
|
Ye D, Wang W, Zhou H, Huang J, Wu W, Gong H, Li Z. In-situ evaluation of porosity in thermal barrier coatings based on the broadening of terahertz time-domain pulses: simulation and experimental investigations. OPTICS EXPRESS 2019; 27:28150-28165. [PMID: 31684573 DOI: 10.1364/oe.27.028150] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 08/27/2019] [Indexed: 06/10/2023]
Abstract
Porosity is one of the most important indicators for the characterization of the comprehensive performance of thermal barrier coatings (TBCs). Herein, we explored a fast, nondestructive porosity evaluation method based on the terahertz time-domain broadening effect. Different preparation process parameters were used to deposit the ceramic coatings, and the porosity ranged from 9.09% to 21.68%. Monte Carlo simulations were conducted to reveal the transitive relation between porosity and the terahertz time-domain broadening at different extinction coefficients and transmission distances. A transmission mode with an incidence angle of 0° was used to estimate the terahertz dielectric properties of ceramic coatings and the relative broadening ratio of terahertz pulses at different porosities. As a result, the Monte Carlo simulations showed that the time-domain broadening effect was enhanced when the extinction coefficient and transmission distances increased. As the porosity increased, the refractive index decreased and the extinction coefficient increased. The latter was more sensitive to minor porosity changes as demonstrated by linear fitting comparisons. Meanwhile, the relative broadening ratio increased when the porosity increased, and reserved the sensitivity of the extinction coefficient to porosity changes. The effect was more obvious on the relative broadening ratio which experienced multiple transmissions and reflections. Moreover, the relative broadening ratio could be obtained faster and in an easier manner compared to the dielectric parameters in both the transmission and reflection modes, based on single-step tests with the use of actual terahertz wave inspection. Finally, this study proposed a novel, convenient, online, nondestructive, and noncontact porosity evaluation method that could be potentially utilized to evaluate the integrity of TBCs in gas turbine blades.
Collapse
|
19
|
Differentiating Generic versus Branded Pharmaceutical Tablets Using Ultra-High-Resolution Optical Coherence Tomography. COATINGS 2019. [DOI: 10.3390/coatings9050326] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Optical coherence tomography (OCT) has recently been demonstrated as a powerful tool to image through pharmaceutical film coatings. Majority of the existing systems can, however, resolve film coatings for thickness greater than 10 µm. Here we report on an ultra-high-resolution (UHR) OCT system, with 1 µm axial and 1.6 µm lateral resolutions, which can resolve thin coatings at approximately 4 µm. We further demonstrate a novel application of the system for differentiating generic and branded suppliers of paracetamol tablets.
Collapse
|
20
|
Nondestructive Interface Morphology Characterization of Thermal Barrier Coatings Using Terahertz Time-Domain Spectroscopy. COATINGS 2019. [DOI: 10.3390/coatings9020089] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In this work, a terahertz time-domain spectroscopy (THz-TDS) system was used to measure the thickness of thermal barrier coatings (TBCs) and characterize the interface morphology of TBCs after erosion. Reflection mode, with an angle of incidence of 0, was used for inspection before and after erosion. The refractive index, thickness, and internal structure evolution tendency of the yttria-stabilized zirconia (YSZ) top coat were estimated under consideration of the interaction between the pulsed THz waves and the TBCs. The surface roughness of the top coat surface was considered for the errors analysis in the refractive index and thickness measurement. To reduce the errors introduced by the refractive index change after erosion, two mathematical models were built to assess the thickness loss. Then, the thickness loss was compared with results estimated by the micrometer inspection method. Finally, the basic erosion sample profile with Ra roughness was obtained, and the broadening of THz pulses were suggested as a possible measure for the top coat porosity change, showing that THz waves can be a novel online non-destructive and non-contact evaluation method that can be widely utilized to evaluate the integrity of TBCs applied to gas turbine blades.
Collapse
|
21
|
A Review of the Applications of OCT for Analysing Pharmaceutical Film Coatings. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8122700] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical manufacturing industry as a fast, contactless and non-destructive modality for quantifying thin film coatings on pharmaceutical dosage forms, which cannot be resolved easily with other techniques. In this topical review, we present an overview of the research that has been performed to date, highlighting key differences between systems and outlining major challenges ahead.
Collapse
|
22
|
Pei C, Lin H, Markl D, Shen YC, Zeitler JA, Elliott JA. A quantitative comparison of in-line coating thickness distributions obtained from a pharmaceutical tablet mixing process using discrete element method and terahertz pulsed imaging. Chem Eng Sci 2018. [DOI: 10.1016/j.ces.2018.06.045] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
23
|
Ewing AV, Kazarian SG. Recent advances in the applications of vibrational spectroscopic imaging and mapping to pharmaceutical formulations. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2018; 197:10-29. [PMID: 29290567 DOI: 10.1016/j.saa.2017.12.055] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 12/13/2017] [Accepted: 12/19/2017] [Indexed: 06/07/2023]
Abstract
Vibrational spectroscopic imaging and mapping approaches have continued in their development and applications for the analysis of pharmaceutical formulations. Obtaining spatially resolved chemical information about the distribution of different components within pharmaceutical formulations is integral for improving the understanding and quality of final drug products. This review aims to summarise some key advances of these technologies over recent years, primarily since 2010. An overview of FTIR, NIR, terahertz spectroscopic imaging and Raman mapping will be presented to give a perspective of the current state-of-the-art of these techniques for studying pharmaceutical samples. This will include their application to reveal spatial information of components that reveals molecular insight of polymorphic or structural changes, behaviour of formulations during dissolution experiments, uniformity of materials and detection of counterfeit products. Furthermore, new advancements will be presented that demonstrate the continuing novel applications of spectroscopic imaging and mapping, namely in FTIR spectroscopy, for studies of microfluidic devices. Whilst much of the recently developed work has been reported by academic groups, examples of the potential impacts of utilising these imaging and mapping technologies to support industrial applications have also been reviewed.
Collapse
Affiliation(s)
- Andrew V Ewing
- Imperial College London, Department of Chemical Engineering, South Kensington Campus, London SW7 2AZ, United Kingdom
| | - Sergei G Kazarian
- Imperial College London, Department of Chemical Engineering, South Kensington Campus, London SW7 2AZ, United Kingdom.
| |
Collapse
|
24
|
Markl D, Wahl P, Pichler H, Sacher S, Khinast JG. Characterization of the coating and tablet core roughness by means of 3D optical coherence tomography. Int J Pharm 2018; 536:459-466. [DOI: 10.1016/j.ijpharm.2017.12.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Revised: 11/30/2017] [Accepted: 12/10/2017] [Indexed: 11/25/2022]
|
25
|
Asymptotic limits on tablet coating variability based on cap-to-band thickness distributions: A discrete element model (DEM) study. Chem Eng Sci 2017. [DOI: 10.1016/j.ces.2017.06.029] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
26
|
Lin H, Dong Y, Markl D, Zhang Z, Shen Y, Zeitler JA. Pharmaceutical Film Coating Catalog for Spectral Domain Optical Coherence Tomography. J Pharm Sci 2017. [DOI: 10.1016/j.xphs.2017.05.032] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
27
|
Zhang J, Williams BM, Lawman S, Atkinson D, Zhang Z, Shen Y, Zheng Y. Non-destructive analysis of flake properties in automotive paints with full-field optical coherence tomography and 3D segmentation. OPTICS EXPRESS 2017; 25:18614-18628. [PMID: 29041059 DOI: 10.1364/oe.25.018614] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Accepted: 06/30/2017] [Indexed: 05/18/2023]
Abstract
Automotive coating systems are designed to protect vehicle bodies from corrosion and enhance their aesthetic value. The number, size and orientation of small metallic flakes in the base coat of the paint has a significant effect on the appearance of automotive bodies. It is important for quality assurance (QA) to be able to measure the properties of these small flakes, which are approximately 10μm in radius, yet current QA techniques are limited to measuring layer thickness. We design and develop a time-domain (TD) full-field (FF) optical coherence tomography (OCT) system to scan automotive panels volumetrically, non-destructively and without contact. We develop and integrate a segmentation method to automatically distinguish flakes and allow measurement of their properties. We test our integrated system on nine sections of five panels and demonstrate that this integrated approach can characterise small flakes in automotive coating systems in 3D, calculating the number, size and orientation accurately and consistently. This has the potential to significantly impact QA testing in the automotive industry.
Collapse
|
28
|
Dong J, Locquet A, Citrin DS. Depth resolution enhancement of terahertz deconvolution by autoregressive spectral extrapolation. OPTICS LETTERS 2017; 42:1828-1831. [PMID: 28454171 DOI: 10.1364/ol.42.001828] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This Letter presents a method for enhancing the depth resolution of terahertz deconvolution based on autoregressive (AR) spectral extrapolation. The terahertz frequency components with a high signal-to-noise ratio (SNR) are modeled with an AR process, and the missing frequency components in the regions with low SNRs are extrapolated based on the AR model. In this way, the entire terahertz frequency spectrum of the impulse response function, corresponding to the material structure, is recovered. This method, which is verified numerically and experimentally, is able to provide a "quasi-ideal" impulse response function and, therefore, greatly enhances the depth resolution for characterizing optically thin layers in the terahertz regime.
Collapse
|
29
|
Spectral Domain Optical Coherence Tomography for Non-Destructive Testing of Protection Coatings on Metal Substrates. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7040364] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
30
|
Lin H, Dong Y, Markl D, Williams BM, Zheng Y, Shen Y, Zeitler JA. Measurement of the Intertablet Coating Uniformity of a Pharmaceutical Pan Coating Process With Combined Terahertz and Optical Coherence Tomography In-Line Sensing. J Pharm Sci 2017; 106:1075-1084. [DOI: 10.1016/j.xphs.2016.12.012] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Revised: 11/29/2016] [Accepted: 12/02/2016] [Indexed: 10/20/2022]
|
31
|
Hitzer P, Bäuerle T, Drieschner T, Ostertag E, Paulsen K, van Lishaut H, Lorenz G, Rebner K. Process analytical techniques for hot-melt extrusion and their application to amorphous solid dispersions. Anal Bioanal Chem 2017; 409:4321-4333. [PMID: 28343348 DOI: 10.1007/s00216-017-0292-z] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 02/09/2017] [Accepted: 03/02/2017] [Indexed: 11/28/2022]
Abstract
Newly developed active pharmaceutical ingredients (APIs) are often poorly soluble in water. As a result the bioavailability of the API in the human body is reduced. One approach to overcome this restriction is the formulation of amorphous solid dispersions (ASDs), e.g., by hot-melt extrusion (HME). Thus, the poorly soluble crystalline form of the API is transferred into a more soluble amorphous form. To reach this aim in HME, the APIs are embedded in a polymer matrix. The resulting amorphous solid dispersions may contain small amounts of residual crystallinity and have the tendency to recrystallize. For the controlled release of the API in the final drug product the amount of crystallinity has to be known. This review assesses the available analytical methods that have been recently used for the characterization of ASDs and the quantification of crystalline API content. Well-established techniques like near- and mid-infrared spectroscopy (NIR and MIR, respectively), Raman spectroscopy, and emerging ones like UV/VIS, terahertz, and ultrasonic spectroscopy are considered in detail. Furthermore, their advantages and limitations are discussed with regard to general practical applicability as process analytical technology (PAT) tools in industrial manufacturing. The review focuses on spectroscopic methods which have been proven as most suitable for in-line and on-line process analytics. Further aspects are spectroscopic techniques that have been or could be integrated into an extruder.
Collapse
Affiliation(s)
- Patrick Hitzer
- Process Analysis and Technology (PA&T), Faculty Applied Chemistry, Reutlingen University, Alteburgstr. 150, 72762, Reutlingen, Germany
| | - Tim Bäuerle
- Process Analysis and Technology (PA&T), Faculty Applied Chemistry, Reutlingen University, Alteburgstr. 150, 72762, Reutlingen, Germany
| | - Tobias Drieschner
- Process Analysis and Technology (PA&T), Faculty Applied Chemistry, Reutlingen University, Alteburgstr. 150, 72762, Reutlingen, Germany
| | - Edwin Ostertag
- Process Analysis and Technology (PA&T), Faculty Applied Chemistry, Reutlingen University, Alteburgstr. 150, 72762, Reutlingen, Germany
| | - Katharina Paulsen
- AbbVie Deutschland GmbH & Co.KG, Knollstr. 50, 67061, Ludwigshafen, Germany
| | - Holger van Lishaut
- AbbVie Deutschland GmbH & Co.KG, Knollstr. 50, 67061, Ludwigshafen, Germany
| | - Günter Lorenz
- Process Analysis and Technology (PA&T), Faculty Applied Chemistry, Reutlingen University, Alteburgstr. 150, 72762, Reutlingen, Germany
| | - Karsten Rebner
- Process Analysis and Technology (PA&T), Faculty Applied Chemistry, Reutlingen University, Alteburgstr. 150, 72762, Reutlingen, Germany.
| |
Collapse
|
32
|
Yang Y, Fang J, Shen L, Shan W. Simulation and evaluation of rupturable coated capsules by finite element method. Int J Pharm 2017; 519:220-229. [DOI: 10.1016/j.ijpharm.2017.01.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Revised: 12/30/2016] [Accepted: 01/12/2017] [Indexed: 11/28/2022]
|
33
|
Dong Y, Lin H, Abolghasemi V, Gan L, Zeitler JA, Shen YC. Investigating Intra-Tablet Coating Uniformity With Spectral-Domain Optical Coherence Tomography. J Pharm Sci 2017; 106:546-553. [DOI: 10.1016/j.xphs.2016.09.021] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2016] [Revised: 09/19/2016] [Accepted: 09/21/2016] [Indexed: 11/26/2022]
|
34
|
da Silva VH, Vieira FS, Rohwedder JJR, Pasquini C, Pereira CF. Multivariate quantification of mebendazole polymorphs by terahertz time domain spectroscopy (THZ-TDS). Analyst 2017; 142:1519-1524. [DOI: 10.1039/c6an02540d] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
An analytical method based on terahertz-time domain spectroscopy (THz-TDS) and PLS regression models to quantify mebendazole polymorphs in pharmaceutical raw material is presented.
Collapse
Affiliation(s)
- Vitor H. da Silva
- Departamento de Química Fundamental
- Universidade Federal de Pernambuco
- Recife
- Brazil
| | | | | | - Celio Pasquini
- Instituto de Química
- Universidade Estadual de Campinas
- Campinas
- Brazil
| | - Claudete F. Pereira
- Departamento de Química Fundamental
- Universidade Federal de Pernambuco
- Recife
- Brazil
| |
Collapse
|
35
|
Dong Y, Lawman S, Zheng Y, Williams D, Zhang J, Shen YC. Nondestructive analysis of automotive paints with spectral domain optical coherence tomography. APPLIED OPTICS 2016; 55:3695-700. [PMID: 27140390 DOI: 10.1364/ao.55.003695] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We have demonstrated for the first time, to our knowledge, the use of optical coherence tomography (OCT) as an analytical tool for nondestructively characterizing the individual paint layer thickness of multiple layered automotive paints. A graph-based segmentation method was used for automatic analysis of the thickness distribution for the top layers of solid color paints. The thicknesses measured with OCT were in good agreement with the optical microscope and ultrasonic techniques that are the current standard in the automobile industry. Because of its high axial resolution (5.5 μm), the OCT technique was shown to be able to resolve the thickness of individual paint layers down to 11 μm. With its high lateral resolution (12.4 μm), the OCT system was also able to measure the cross-sectional area of the aluminum flakes in a metallic automotive paint. The range of values measured was 300-1850 μm2. In summary, the proposed OCT is a noncontact, high-resolution technique that has the potential for inclusion as part of the quality assurance process in automobile coating.
Collapse
|
36
|
Wang Z, Zou Y, Li W, Wang X, Zhang M, Wang W. Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome. Medicine (Baltimore) 2015; 94:e1641. [PMID: 26554764 PMCID: PMC4915865 DOI: 10.1097/md.0000000000001641] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2015] [Revised: 08/25/2015] [Accepted: 08/27/2015] [Indexed: 11/26/2022] Open
Abstract
This study was aimed to investigate the fundus changes of patients with pregnancy-induced hypertension syndrome (PIHS) using optical coherence tomography (OCT) technology and contrast sensitivity (CS) tests.Ninety-eight patients with PIHS underwent routine eye examinations including vision correction, fundus examination, OCT, and CS tests. The CS test was performed at low, medium, and high frequency, respectively. Moreover, the difference in CS tests between 2 groups was analyzed by independent-samples T test. The Kruskal-Wallis rank sum test and linear regression model were used to detect the correlation of OCT with CS, respectively. Meanwhile Satterthwaite approximate T test was adopted for pairwise comparisons after nonparametric analysis of variance.The OCT test revealed that 56.76% of the examined eyes showed shallow retinal detachment in the macula lutea and around the optic disk. The differences in CS at each spatial frequency between the case and control group were statistically significant (P < 0.01). Besides, OCT manifestations were associated with CS at each spacial frequency including 1.5, 3, 6, 12, and 18 frequency (P < 0.01). And patients with abnormal manifestations of OCT showed lower CS at each spacial frequency than those without abnormal OCT manifestations. What's more the OCT manifestation 1 showed the greatest impact on CS at each spacial frequency.The results showed that abnormal OCT manifestations were correlated with CS in PIHS. OCT and CS tests might be valuable methods in observing fundus changes for PIHS patients.
Collapse
Affiliation(s)
- Zhixue Wang
- From the Department of Ophthalmology, Cangzhou Central Hospital, Cangzhou, Hebei, China
| | | | | | | | | | | |
Collapse
|