1
|
Zhang X, Nadeem SA, DiCamillo PA, Shibli-Rahhal A, Regan EA, Barr RG, Hoffman EA, Comellas AP, Saha PK. Ultra-low dose hip CT-based automated measurement of volumetric bone mineral density at proximal femoral subregions. Med Phys 2024. [PMID: 39042053 DOI: 10.1002/mp.17319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 06/07/2024] [Accepted: 07/08/2024] [Indexed: 07/24/2024] Open
Abstract
BACKGROUND Forty to fifty percent of women and 13%-22% of men experience an osteoporosis-related fragility fracture in their lifetimes. After the age of 50 years, the risk of hip fracture doubles in every 10 years. x-Ray based DXA is currently clinically used to diagnose osteoporosis and predict fracture risk. However, it provides only 2-D representation of bone and is associated with other technical limitations. Thus, alternative methods are needed. PURPOSE To develop and evaluate an ultra-low dose (ULD) hip CT-based automated method for assessment of volumetric bone mineral density (vBMD) at proximal femoral subregions. METHODS An automated method was developed to segment the proximal femur in ULD hip CT images and delineate femoral subregions. The computational pipeline consists of deep learning (DL)-based computation of femur likelihood map followed by shape model-based femur segmentation and finite element analysis-based warping of a reference subregion labeling onto individual femur shapes. Finally, vBMD is computed over each subregion in the target image using a calibration phantom scan. A total of 100 participants (50 females) were recruited from the Genetic Epidemiology of COPD (COPDGene) study, and ULD hip CT imaging, equivalent to 18 days of background radiation received by U.S. residents, was performed on each participant. Additional hip CT imaging using a clinical protocol was performed on 12 participants and repeat ULD hip CT was acquired on another five participants. ULD CT images from 80 participants were used to train the DL network; ULD CT images of the remaining 20 participants as well as clinical and repeat ULD CT images were used to evaluate the accuracy, generalizability, and reproducibility of segmentation of femoral subregions. Finally, clinical CT and repeat ULD CT images were used to evaluate accuracy and reproducibility of ULD CT-based automated measurements of femoral vBMD. RESULTS Dice scores of accuracy (n = 20), reproducibility (n = 5), and generalizability (n = 12) of ULD CT-based automated subregion segmentation were 0.990, 0.982, and 0.977, respectively, for the femoral head and 0.941, 0.970, and 0.960, respectively, for the femoral neck. ULD CT-based regional vBMD showed Pearson and concordance correlation coefficients of 0.994 and 0.977, respectively, and a root-mean-square coefficient of variation (RMSCV) (%) of 1.39% with the clinical CT-derived reference measure. After 3-digit approximation, each of Pearson and concordance correlation coefficients as well as intraclass correlation coefficient (ICC) between baseline and repeat scans were 0.996 with RMSCV of 0.72%. Results of ULD CT-based bone analysis on 100 participants (age (mean ± SD) 73.6 ± 6.6 years) show that males have significantly greater (p < 0.01) vBMD at the femoral head and trochanteric regions than females, while females have moderately greater vBMD (p = 0.05) at the medial half of the femoral neck than males. CONCLUSION Deep learning, combined with shape model and finite element analysis, offers an accurate, reproducible, and generalizable algorithm for automated segmentation of the proximal femur and anatomic femoral subregions using ULD hip CT images. ULD CT-based regional measures of femoral vBMD are accurate and reproducible and demonstrate regional differences between males and females.
Collapse
Affiliation(s)
- Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA
| | - Syed Ahmed Nadeem
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| | - Paul A DiCamillo
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| | - Amal Shibli-Rahhal
- Department of Internal Medicine, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| | - Elizabeth A Regan
- Department of Medicine, Division of Rheumatology, National Jewish Health, Denver, Colorado, USA
| | - R Graham Barr
- Department of Medicine, Columbia University, New York, New York, USA
| | - Eric A Hoffman
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
- Department of Internal Medicine, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
- Department of Biomedical Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA
| | - Alejandro P Comellas
- Department of Internal Medicine, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| | - Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| |
Collapse
|
2
|
Guha I, Nadeem SA, Zhang X, DiCamillo PA, Levy SM, Wang G, Saha PK. Deep learning-based harmonization of trabecular bone microstructures between high- and low-resolution CT imaging. Med Phys 2024; 51:4258-4270. [PMID: 38415781 PMCID: PMC11147700 DOI: 10.1002/mp.17003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 02/09/2024] [Accepted: 02/12/2024] [Indexed: 02/29/2024] Open
Abstract
BACKGROUND Osteoporosis is a bone disease related to increased bone loss and fracture-risk. The variability in bone strength is partially explained by bone mineral density (BMD), and the remainder is contributed by bone microstructure. Recently, clinical CT has emerged as a viable option for in vivo bone microstructural imaging. Wide variations in spatial-resolution and other imaging features among different CT scanners add inconsistency to derived bone microstructural metrics, urging the need for harmonization of image data from different scanners. PURPOSE This paper presents a new deep learning (DL) method for the harmonization of bone microstructural images derived from low- and high-resolution CT scanners and evaluates the method's performance at the levels of image data as well as derived microstructural metrics. METHODS We generalized a three-dimensional (3D) version of GAN-CIRCLE that applies two generative adversarial networks (GANs) constrained by the identical, residual, and cycle learning ensemble (CIRCLE). Two GAN modules simultaneously learn to map low-resolution CT (LRCT) to high-resolution CT (HRCT) and vice versa. Twenty volunteers were recruited. LRCT and HRCT scans of the distal tibia of their left legs were acquired. Five-hundred pairs of LRCT and HRCT image blocks of64 × 64 × 64 $64 \times 64 \times 64 $ voxels were sampled for each of the twelve volunteers and used for training in supervised as well as unsupervised setups. LRCT and HRCT images of the remaining eight volunteers were used for evaluation. LRCT blocks were sampled at 32 voxel intervals in each coordinate direction and predicted HRCT blocks were stitched to generate a predicted HRCT image. RESULTS Mean ± standard deviation of structural similarity (SSIM) values between predicted and true HRCT using both 3DGAN-CIRCLE-based supervised (0.84 ± 0.03) and unsupervised (0.83 ± 0.04) methods were significantly (p < 0.001) higher than the mean SSIM value between LRCT and true HRCT (0.75 ± 0.03). All Tb measures derived from predicted HRCT by the supervised 3DGAN-CIRCLE showed higher agreement (CCC ∈ $ \in $ [0.956 0.991]) with the reference values from true HRCT as compared to LRCT-derived values (CCC ∈ $ \in $ [0.732 0.989]). For all Tb measures, except Tb plate-width (CCC = 0.866), the unsupervised 3DGAN-CIRCLE showed high agreement (CCC ∈ $ \in $ [0.920 0.964]) with the true HRCT-derived reference measures. Moreover, Bland-Altman plots showed that supervised 3DGAN-CIRCLE predicted HRCT reduces bias and variability in residual values of different Tb measures as compared to LRCT and unsupervised 3DGAN-CIRCLE predicted HRCT. The supervised 3DGAN-CIRCLE method produced significantly improved performance (p < 0.001) for all Tb measures as compared to the two DL-based supervised methods available in the literature. CONCLUSIONS 3DGAN-CIRCLE, trained in either unsupervised or supervised fashion, generates HRCT images with high structural similarity to the reference true HRCT images. The supervised 3DGAN-CIRCLE improves agreements of computed Tb microstructural measures with their reference values and outperforms the unsupervised 3DGAN-CIRCLE. 3DGAN-CIRCLE offers a viable DL solution to retrospectively improve image resolution, which may aid in data harmonization in multi-site longitudinal studies where scanner mismatch is unavoidable.
Collapse
Affiliation(s)
- Indranil Guha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA
| | - Syed Ahmed Nadeem
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| | - Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA
| | - Paul A DiCamillo
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| | - Steven M Levy
- Department of Preventive and Community Dentistry, University of Iowa, Iowa City, Iowa, USA
- Department of Epidemiology, University of Iowa, Iowa City, Iowa, USA
| | - Ge Wang
- Biomedical Imaging Center, BME/CBIS, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, Iowa, USA
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| |
Collapse
|
3
|
Berni M, Marchiori G, Baleani M, Giavaresi G, Lopomo NF. Biomechanics of the Human Osteochondral Unit: A Systematic Review. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1698. [PMID: 38612211 PMCID: PMC11012636 DOI: 10.3390/ma17071698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 03/17/2024] [Accepted: 03/26/2024] [Indexed: 04/14/2024]
Abstract
The damping system ensured by the osteochondral (OC) unit is essential to deploy the forces generated within load-bearing joints during locomotion, allowing furthermore low-friction sliding motion between bone segments. The OC unit is a multi-layer structure including articular cartilage, as well as subchondral and trabecular bone. The interplay between the OC tissues is essential in maintaining the joint functionality; altered loading patterns can trigger biological processes that could lead to degenerative joint diseases like osteoarthritis. Currently, no effective treatments are available to avoid degeneration beyond tissues' recovery capabilities. A thorough comprehension on the mechanical behaviour of the OC unit is essential to (i) soundly elucidate its overall response to intra-articular loads for developing diagnostic tools capable of detecting non-physiological strain levels, (ii) properly evaluate the efficacy of innovative treatments in restoring physiological strain levels, and (iii) optimize regenerative medicine approaches as potential and less-invasive alternatives to arthroplasty when irreversible damage has occurred. Therefore, the leading aim of this review was to provide an overview of the state-of-the-art-up to 2022-about the mechanical behaviour of the OC unit. A systematic search is performed, according to PRISMA standards, by focusing on studies that experimentally assess the human lower-limb joints' OC tissues. A multi-criteria decision-making method is proposed to quantitatively evaluate eligible studies, in order to highlight only the insights retrieved through sound and robust approaches. This review revealed that studies on human lower limbs are focusing on the knee and articular cartilage, while hip and trabecular bone studies are declining, and the ankle and subchondral bone are poorly investigated. Compression and indentation are the most common experimental techniques studying the mechanical behaviour of the OC tissues, with indentation also being able to provide information at the micro- and nanoscales. While a certain comparability among studies was highlighted, none of the identified testing protocols are currently recognised as standard for any of the OC tissues. The fibril-network-reinforced poro-viscoelastic constitutive model has become common for describing the response of the articular cartilage, while the models describing the mechanical behaviour of mineralised tissues are usually simpler (i.e., linear elastic, elasto-plastic). Most advanced studies have tested and modelled multiple tissues of the same OC unit but have done so individually rather than through integrated approaches. Therefore, efforts should be made in simultaneously evaluating the comprehensive response of the OC unit to intra-articular loads and the interplay between the OC tissues. In this regard, a multidisciplinary approach combining complementary techniques, e.g., full-field imaging, mechanical testing, and computational approaches, should be implemented and validated. Furthermore, the next challenge entails transferring this assessment to a non-invasive approach, allowing its application in vivo, in order to increase its diagnostic and prognostic potential.
Collapse
Affiliation(s)
- Matteo Berni
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy; (M.B.); (M.B.)
| | - Gregorio Marchiori
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy;
| | - Massimiliano Baleani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy; (M.B.); (M.B.)
| | - Gianluca Giavaresi
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy;
| | | |
Collapse
|
4
|
Chan TJ, Rajapakse CS. A Super-Resolution Diffusion Model for Recovering Bone Microstructure from CT Images. Radiol Artif Intell 2023; 5:e220251. [PMID: 38074790 PMCID: PMC10698592 DOI: 10.1148/ryai.220251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 08/02/2023] [Accepted: 09/01/2023] [Indexed: 02/12/2024]
Abstract
Purpose To use a diffusion-based deep learning model to recover bone microstructure from low-resolution images of the proximal femur, a common site of traumatic osteoporotic fractures. Materials and Methods Training and testing data in this retrospective study consisted of high-resolution cadaveric micro-CT scans (n = 26), which served as ground truth. The images were downsampled prior to use for model training. The model was used to increase spatial resolution in these low-resolution images threefold, from 0.72 mm to 0.24 mm, sufficient to visualize bone microstructure. Model performance was validated using microstructural metrics and finite element simulation-derived stiffness of trabecular regions. Performance was also evaluated across a handful of image quality assessment metrics. Correlations between model performance and ground truth were assessed using intraclass correlation coefficients (ICCs) and Pearson correlation coefficients. Results Compared with popular deep learning baselines, the proposed model exhibited greater accuracy (mean ICC of proposed model, 0.92 vs ICC of next best method, 0.83) and lower bias (mean difference in means, 3.80% vs 10.00%, respectively) across the physiologic metrics. Two gradient-based image quality metrics strongly correlated with accuracy across structural and mechanical criteria (r > 0.89). Conclusion The proposed method may enable accurate measurements of bone structure and strength with a radiation dose on par with current clinical imaging protocols, improving the viability of clinical CT for assessing bone health.Keywords: CT, Image Postprocessing, Skeletal-Appendicular, Long Bones, Radiation Effects, Quantification, Prognosis, Semisupervised Learning Online supplemental material is available for this article. © RSNA, 2023.
Collapse
Affiliation(s)
- Trevor J Chan
- From the Departments of Bioengineering (T.J.C.), Radiology (T.J.C., C.S.R.), and Orthopedic Surgery (C.S.R.), University of Pennsylvania, 3400 Spruce St, Philadelphia, PA 19104-6243
| | - Chamith S Rajapakse
- From the Departments of Bioengineering (T.J.C.), Radiology (T.J.C., C.S.R.), and Orthopedic Surgery (C.S.R.), University of Pennsylvania, 3400 Spruce St, Philadelphia, PA 19104-6243
| |
Collapse
|
5
|
Hasegawa H, Nango N, Machida M. Evaluation of Trabecular Microstructure of Cancellous Bone Using Quarter-Detector Computed Tomography. Diagnostics (Basel) 2023; 13:diagnostics13071240. [PMID: 37046458 PMCID: PMC10093188 DOI: 10.3390/diagnostics13071240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/22/2023] [Accepted: 03/23/2023] [Indexed: 03/29/2023] Open
Abstract
Quarter-detector computed tomography (QDCT) is an ultra-high-spatial-resolution imaging technique. This study aimed to verify the validity of trabecular structure evaluation using a QDCT scanner in the diagnosis of osteoporosis. We used a cancellous bone specimen image of the second lumbar vertebrae of an adult male with moderate osteoporosis. To obtain QDCT images, we created a three-dimensional model from micro-CT images of the specimen. Statistical analysis was performed on the relationship between micro-CT and QDCT imaging modalities. The differences between micro-CT and QDCT were assessed based on their significance with respect to the calculated mean measurements using the Mann–Whitney test. Single regression analysis was performed using linear regression, with micro-CT and QDCT as the explanatory and objective variables, respectively, to determine the relationship of the measured values between the two modalities. By applying the necessary correction to the micro-CT measured values, it is possible to perform an analysis equivalent to micro-CT, which offers higher spatial resolution than QDCT. We found evidence that if QDCT can be used, trabecular structure evaluation may contribute to image diagnosis to evaluate practical bone fragility.
Collapse
|
6
|
Guha I, Zhang X, Nadeem SA, Levy SM, Saha PK. Continuum finite element analysis generalizes in vivotrabecular bone microstructural strength measures between two CT scanners with different image resolution. Biomed Phys Eng Express 2023; 9:025012. [PMID: 36763987 PMCID: PMC9945196 DOI: 10.1088/2057-1976/acbb0a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 02/10/2023] [Indexed: 02/12/2023]
Abstract
Fragility of trabecular bone (Tb) microstructure is increased in osteoporosis, which is associated with rapid bone loss and enhanced fracture-risk. Accurate assessment of Tb strength usingin vivoimaging available in clinical settings will be significant for management of osteoporosis and understanding its pathogenesis. Emerging CT technology, featured with high image resolution, fast scan-speed, and wide clinical access, is a promising alternative forin vivoTb imaging. However, variation in image resolution among different CT scanners pose a major hurdle in CT-based bone studies. This paper presents nonlinear continuum finite element (FE) methods for computation of Tb strength fromin vivoCT imaging and evaluates their generalizability between two scanners with different image resolution. Continuum FE-based measures of Tb strength under different loading conditions were found to be highly reproducible (ICC ≥ 0.93) using ankle images of twenty healthy volunteers acquired on low- and high-resolution CT scanners 44.6 ± 2.7 days apart. FE stress propagation was mostly confined to Tb micro-network (2.3 ± 1.7 MPa) with nominal leakages over the marrow space (0.4 ± 0.5 MPa) complying with the fundamental principle of mechanics atin vivoimaging. In summary, nonlinear continuum FE-based Tb strength measures are reproducible among different CT scanners and suitable for multi-site longitudinal human studies.
Collapse
Affiliation(s)
- Indranil Guha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, United States of America
| | - Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, United States of America
| | - Syed Ahmed Nadeem
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA, United States of America
| | - Steven M Levy
- Department of Epidemiology, College of Public Health, University of Iowa, Iowa City, IA, United States of America,
Department of Preventive and Community Dentistry, College of Dentistry, University of Iowa, Iowa City, IA, United States of America
| | - Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, United States of America,
Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA, United States of America
| |
Collapse
|
7
|
Huang W, Cai XH, Li YR, Xu F, Jiang XH, Wang D, Tu M. The association between paraspinal muscle degeneration and osteoporotic vertebral compression fracture severity in postmenopausal women. J Back Musculoskelet Rehabil 2022; 36:323-329. [PMID: 36155499 PMCID: PMC10041424 DOI: 10.3233/bmr-220059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND According to reports in the literature, osteoporotic vertebral compression fracture (OVCF) is associated with paraspinal muscle degeneration; however, the association between the severity of OVCF and paraspinal muscle degeneration is not clear. OBJECTIVE The purpose of this study was to investigate the association between paraspinal muscle degeneration and OVCF severity in postmenopausal women. METHODS Three hundred and seventy-six MRI images from 47 patients were collected and analyzed. Sagittal and axial coronal T2-weighted images were used to measure the fractured vertebra sagittal cross-sectional area (FSCSA), the adjacent normal vertebral body sagittal cross-sectional area (NSCSA), paraspinal muscle cross-sectional area (CSA), and the fat cross-sectional area (FCSA). The ratio of fractured vertebra compressed sagittal cross-sectional area (RCSA) and fatty infiltration ratio (FIR) was subsequently calculated. The formulas for RCSA and FIR calculations are as follows: RCSA = (NSCSA-FSCSA)/NSCSA; FIR = FCSA/CSA. RCSA and FIR represent the severity of OVCF and paraspinal muscle degeneration, respectively. RESULTS The correlation between paraspinal muscle degeneration and OVCF severity was analyzed using the Pearson correlation, and multiple regression analysis was performed to explore related risk factors. OVCF severity was closely associated with paraspinal muscle degeneration (L3/4 FIR r= 0.704, P< 0.05; L4/5 FIR r= 0.578, P< 0.05; L5/S1 FIR r= 0.581, P< 0.05). Multiple regression analysis demonstrated that the risk factor for OVCF severity was L3/4 FIR (β= 0.421, P= 0.033). CONCLUSION OVCF severity was associated with the FIR of paraspinal muscles, and L3/4 FIR was a predictive factor for OVCF severity in postmenopausal women.
Collapse
Affiliation(s)
- Wei Huang
- Hubei University of Chinese Medicine, Wuhan, China.,Department of Spine Surgery, Jingmen No. 2 People's Hospital, Jingmen, Wuhan, China.,Department of Orthopedics, PLA Middle Military Command General Hospital, Wuhan, China
| | - Xian-Hua Cai
- Hubei University of Chinese Medicine, Wuhan, China.,Department of Orthopedics, PLA Middle Military Command General Hospital, Wuhan, China
| | - Yi-Rong Li
- Department of Spine Surgery, Jingmen No. 2 People's Hospital, Jingmen, Wuhan, China
| | - Feng Xu
- Department of Orthopedics, PLA Middle Military Command General Hospital, Wuhan, China
| | - Xin-Hao Jiang
- Department of Spine Surgery, Jingmen No. 2 People's Hospital, Jingmen, Wuhan, China
| | - Dan Wang
- Department of Spine Surgery, Jingmen No. 2 People's Hospital, Jingmen, Wuhan, China
| | - Min Tu
- Department of Spine Surgery, Jingmen No. 2 People's Hospital, Jingmen, Wuhan, China
| |
Collapse
|
8
|
Peña JA, Klein L, Maier J, Damm T, Schlemmer HP, Engelke K, Glüer CC, Kachelrieß M, Sawall S. Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT. Z Med Phys 2022; 32:403-416. [PMID: 35597742 PMCID: PMC9948845 DOI: 10.1016/j.zemedi.2022.04.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 03/17/2022] [Accepted: 04/03/2022] [Indexed: 01/23/2023]
Abstract
Photon-counting (PC) detectors for clinical computed tomography (CT) may offer improved imaging capabilities compared to conventional energy-integrating (EI) detectors, e.g. superior spatial resolution and detective efficiency. We here investigate if PCCT can reduce the administered dose in examinations aimed at quantifying trabecular bone microstructure. Five human vertebral bodies were scanned three times in an abdomen phantom (QRM, Germany) using an experimental dual-source CT (Somatom CounT, Siemens Healthineers, Germany) housing an EI detector (0.60 mm pixel size at the iso-center) and a PC detector (0.25 mm pixel size). A tube voltage of 120 kV was used. Tube current-time product for EICT was 355 mAs (23.8 mGy CTDI32 cm). Dose-matched UHR-PCCT (UHRdm, 23.8 mGy) and noise-matched acquisitions (UHRnm, 10.5 mGy) were performed and reconstructed to a voxel size of 0.156 mm using a sharp kernel. Measurements of bone mineral density (BMD) and trabecular separation (Tb.Sp) and Tb.Sp percentiles reflecting the different scales of the trabecular interspacing were performed and compared to a gold-standard measurement using a peripheral CT device (XtremeCT, SCANCO Medical, Switzerland) with an isotropic voxel size of 0.082 mm and 6.6 mGy CTDI10 cm. The image noise was quantified and the relative error with respect to the gold-standard along with the agreement between CT protocols using Lin's concordance correlation coefficient (rCCC) were calculated. The Mean ± StdDev of the measured image noise levels in EICT was 109.6 ± 3.9 HU. UHRdm acquisitions (same dose as EICT) showed a significantly lower noise level of 78.6 ± 4.6 HU (p = 0.0122). UHRnm (44% dose of EICT) showed a noise level of 115.8 ± 3.7 HU, very similar to EICT at the same spatial resolution. For BMD the overall Mean ± StdDev for EI, UHRdm and UHRnm were 114.8 ± 28.6 mgHA/cm3, 121.6 ± 28.8 mgHA/cm3 and 121.5 ± 28.6 mgHA/cm3, respectively, compared to 123.1 ± 25.5 mgHA/cm3 for XtremeCT. For Tb.Sp these values were 1.86 ± 0.54 mm, 1.80 ± 0.56 mm and 1.84 ± 0.52 mm, respectively, compared to 1.66 ± 0.48 mm for XtremeCT. The ranking of the vertebrae with regard to Tb.Sp data was maintained throughout all Tb.Sp percentiles and among the CT protocols and the gold-standard. The agreement between protocols was very good for all comparisons: UHRnm vs. EICT (BMD rCCC = 0.97; Tb.Sp rCCC = 0.998), UHRnm vs. UHRdm (BMD rCCC = 0.998; Tb.Sp rCCC = 0.993) and UHRdm vs. EICT (BMD rCCC = 0.97; Tb.Sp rCCC = 0.991). Consequently, the relative RMS-errors from linear regressions against the gold-standard for EICT, UHRdm and UHRnm were very similar for BMD (7.1%, 5.2% and 5.4%) and for Tb.Sp (3.3%, 3.3% and 2.9%), with a much lower radiation dose for UHRnm. Short-term reproducibility for BMD measurements was similar and below 0.2% for all protocols, but for Tb.Sp showed better results for UHR (about 1/3 of the level for EICT). In conclusion, CT with UHR-PC detectors demonstrated lower image noise and better reproducibility for assessments of bone microstructure at similar dose levels. For UHRnm, radiation exposure levels could be reduced by 56% without deterioration of performance levels in the assessment of bone mineral density and bone microstructure.
Collapse
Affiliation(s)
- Jaime A Peña
- Section Biomedical Imaging, Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Am Botanischen Garten 14, 24118 Kiel, Germany.
| | - Laura Klein
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Department of Physics and Astronomy, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 226, 69120 Heidelberg, Germany
| | - Joscha Maier
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Timo Damm
- Section Biomedical Imaging, Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Am Botanischen Garten 14, 24118 Kiel, Germany
| | - Heinz-Peter Schlemmer
- Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Klaus Engelke
- Institute of Medical Physics, Friedrich-Alexander University Erlangen-Nürnberg, Henkestraße 91, 91052 Erlangen, Germany; Department of Medicine 3, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Claus-Christian Glüer
- Section Biomedical Imaging, Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Am Botanischen Garten 14, 24118 Kiel, Germany
| | - Marc Kachelrieß
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany
| | - Stefan Sawall
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany
| |
Collapse
|
9
|
Guha I, Zhang X, Rajapakse CS, Letuchy EM, Chang G, Janz KF, Torner JC, Levy SM, Saha PK. CT
‐based Stiffness Measures of Trabecular Bone Microstructure — Cadaveric Validation and
In Vivo
Application. JBMR Plus 2022; 6:e10627. [PMID: 35720662 PMCID: PMC9189917 DOI: 10.1002/jbm4.10627] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 03/14/2022] [Accepted: 03/29/2022] [Indexed: 11/09/2022] Open
Abstract
Osteoporosis causes bone fragility and elevates fracture risk. Applications of finite element (FE) analysis (FEA) for assessment of trabecular bone (Tb) microstructural strength at whole‐body computed tomography (CT) imaging are limited due to challenges with Tb microstructural segmentation. We present a nonlinear FEA method for distal tibia CT scans evading binary segmentation of Tb microstructure, while accounting for bone microstructural distribution. First, the tibial axis in a CT scan was aligned with the FE loading axis. FE cubic mesh elements were modeled using image voxels, and CT intensity values were calibrated to ash density defining mechanical properties at individual elements. For FEA of an upright volume of interest (VOI), the bottom surface was fixed, and a constant displacement was applied at each vertex on the top surface simulating different loading conditions. The method was implemented and optimized using the ANSYS software. CT‐derived computational modulus values were repeat scan reproducible (intraclass correlation coefficient [ICC] ≥ 0.97) and highly correlated (r ≥ 0.86) with the micro‐CT (μCT)‐derived values. FEA‐derived von Mises stresses over the segmented Tb microregion were significantly higher (p < 1 × 10−11) than that over the marrow space. In vivo results showed that both shear and compressive modulus for males were higher (p < 0.01) than for females. Effect sizes for different modulus measures between males and females were moderate‐to‐high (≥0.55) and reduced to small‐to‐negligible (<0.40) when adjusted for pure lean mass. Among body size and composition attributes, pure lean mass and height showed highest (r ∈ [0.45 0.56]) and lowest (r ∈ [0.25 0.39]) linear correlation, respectively, with FE‐derived modulus measures. In summary, CT‐based nonlinear FEA provides an effective surrogate measure of Tb microstructural stiffness, and the relaxation of binary segmentation will extend the scope for FEA in human studies using in vivo imaging at relatively low‐resolution. © 2022 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Indranil Guha
- Department of Electrical and Computer Engineering University of Iowa Iowa City IA USA
| | - Xialiou Zhang
- Department of Electrical and Computer Engineering University of Iowa Iowa City IA USA
| | - Chamith S. Rajapakse
- Departments of Radiology and Orthopedic Surgery University of Pennsylvania PA USA
| | | | - Gregory Chang
- Department of Radiology New York University Grossman School of Medicine NY USA
| | - Kathleen F. Janz
- Department of Health and Human Physiology University of Iowa Iowa City IA USA
| | - James C. Torner
- Department of Epidemiology University of Iowa Iowa City IA USA
| | - Steven M. Levy
- Department of Epidemiology University of Iowa Iowa City IA USA
- Department of Preventive and Community Dentistry University of Iowa Iowa City IA USA
| | - Punam K. Saha
- Department of Electrical and Computer Engineering University of Iowa Iowa City IA USA
- Department of Radiology University of Iowa Iowa City IA USA
| |
Collapse
|
10
|
Guha I, Zhang X, Rajapakse CS, Chang G, Saha PK. Finite element analysis of trabecular bone microstructure using CT imaging and continuum mechanical modelling. Med Phys 2022; 49:3886-3899. [PMID: 35319784 PMCID: PMC9325403 DOI: 10.1002/mp.15629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/09/2022] [Accepted: 03/11/2022] [Indexed: 11/16/2022] Open
Abstract
Purpose Osteoporosis is a bone disease associated with enhanced bone loss, microstructural degeneration, and fracture‐risk. Finite element (FE) modeling is used to estimate trabecular bone (Tb) modulus from high‐resolution three‐dimensional (3‐D) imaging modalities including micro‐computed tomography (CT), magnetic resonance imaging (MRI), and high‐resolution peripheral quantitative CT (HR‐pQCT). This paper validates an application of voxel‐based continuum finite element analysis (FEA) to predict Tb modulus from clinical CT imaging under a condition similar to in vivo imaging by comparing with measures derived by micro‐CT and experimental approaches. Method Voxel‐based continuum FEA methods for CT imaging were implemented using linear and nonlinear models and applied on distal tibial scans under a condition similar to in vivo imaging. First, tibial axis in a CT scan was aligned with the coordinate z‐axis at 150 μm isotropic voxels. FEA was applied on an upright cylindrical volume of interests (VOI) with its axis coinciding with the tibial bone axis. Voxel volume, edge, and vertex elements and their connectivity were defined as per the isotropic image grid. A calibration phantom was used to calibrate CT numbers in Hounsfield unit to bone mineral density (BMD) values, which was then converted into calcium hydroxyapatite (CHA) density. Mechanical properties at each voxel volume element was defined using its ash‐density defined on CT‐derived CHA density. For FEA, the bottom surface of the cylindrical VOI was fixed and a constant displacement was applied along the z‐direction at each vertex element on the top surface to simulate a physical axial compressive loading condition. Finally, a Poisson's ratio of 0.3 was applied, and Tb modulus (MPa) was computed as the ratio of average von Mises stress (MPa) of volume elements on the top surface and the applied displacement. FEA parameters including mesh element size, substep number, and different tolerance values were optimized. Results CT‐derived Tb modulus values using continuum FEA showed high linear correlation with the micro‐CT‐derived reference values (r ∈ [0.87 0.90]) as well as experimentally measured values (r ∈ [0.80 0.87]). Linear correlation of computed modulus with their reference values using continuum FEA with linear modeling was comparable with that obtained by nonlinear modeling. Nonlinear continuum FEA‐based modulus values (mean of 1087.2 MPa) showed greater difference from their reference values (mean of 1498.9 MPa using micro‐CT‐based FEA) as compared with linear continuum methods. High repeat CT scan reproducibility (intra‐class correlation [ICC] = 0.98) was observed for computed modulus values using both linear and nonlinear continuum FEA. It was observed that high stress regions coincide with Tb microstructure as fuzzily characterized by BMD values. Distributions of von Mises stress over Tb microstructure and marrow regions were significantly different (p < 10–8). Conclusion Voxel‐based continuum FEA offers surrogate measures of Tb modulus from CT imaging under a condition similar to in vivo imaging that alleviates the need for segmentation of Tb and marrow regions, while accounting for bone distribution at the microstructural level. This relaxation of binary segmentation will extend the scope of FEA application to assess mechanical properties of bone microstructure at relatively low‐resolution imaging.
Collapse
Affiliation(s)
- Indranil Guha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, 52242, USA
| | - Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, 52242, USA
| | - Chamith S Rajapakse
- Departments of Radiology and Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Gregory Chang
- Department of Radiology, New York University Grossman School of Medicine, New York, NY, 10016, USA
| | - Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, 52242, USA.,Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA, 52242, USA
| |
Collapse
|
11
|
Jin D, Zheng H, Zhao Q, Wang C, Zhang M, Yuan H. Generation of Vertebra Micro-CT-like Image from MDCT: A Deep-Learning-Based Image Enhancement Approach. Tomography 2021; 7:767-782. [PMID: 34842849 PMCID: PMC8628970 DOI: 10.3390/tomography7040064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 11/05/2021] [Accepted: 11/09/2021] [Indexed: 11/26/2022] Open
Abstract
This paper proposes a deep-learning-based image enhancement approach that can generate high-resolution micro-CT-like images from multidetector computed tomography (MDCT). A total of 12,500 MDCT and micro-CT image pairs were obtained from 25 vertebral specimens. Then, a pix2pixHD model was trained and evaluated using the structural similarity index measure (SSIM) and Fréchet inception distance (FID). We performed subjective assessments of the micro-CT-like images based on five aspects. Micro-CT and micro-CT-like image-derived trabecular bone microstructures were compared, and the underlying correlations were analyzed. The results showed that the pix2pixHD method (SSIM, 0.804 ± 0.037 and FID, 43.598 ± 9.108) outperformed the two control methods (pix2pix and CRN) in enhancing MDCT images (p < 0.05). According to the subjective assessment, the pix2pixHD-derived micro-CT-like images showed no significant difference from the micro-CT images in terms of contrast and shadow (p > 0.05) but demonstrated slightly lower noise, sharpness and trabecular bone texture (p < 0.05). Compared with the trabecular microstructure parameters of micro-CT images, those of pix2pixHD-derived micro-CT-like images showed no significant differences in bone volume fraction (BV/TV) (p > 0.05) and significant correlations in trabecular thickness (Tb.Th) and trabecular spacing (Tb.Sp) (Tb.Th, R = 0.90, p < 0.05; Tb.Sp, R = 0.88, p < 0.05). The proposed method can enhance the resolution of MDCT and obtain micro-CT-like images, which may provide new diagnostic criteria and a predictive basis for osteoporosis and related fractures.
Collapse
Affiliation(s)
- Dan Jin
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
| | - Han Zheng
- School of Traffic and Transportation, Beijing Jiaotong University, Beijing 100044, China;
| | - Qingqing Zhao
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
| | - Chunjie Wang
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
| | - Mengze Zhang
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
| | - Huishu Yuan
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
- Correspondence:
| |
Collapse
|
12
|
Saha PK, Oweis RR, Zhang X, Letuchy E, Eichenberger-Gilmore JM, Burns TL, Warren JJ, Janz KF, Torner JC, Snetselaar LG, Levy SM. Effects of fluoride intake on cortical and trabecular bone microstructure at early adulthood using multi-row detector computed tomography (MDCT). Bone 2021; 146:115882. [PMID: 33578032 PMCID: PMC8009824 DOI: 10.1016/j.bone.2021.115882] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 01/28/2021] [Accepted: 02/07/2021] [Indexed: 11/18/2022]
Abstract
PURPOSE The aim of this study was to examine the effects of period-specific and cumulative fluoride (F) intake on bone at the levels of cortical and trabecular bone microstructural outcomes at early adulthood using emerging multi-row detector computed tomography (MDCT)-based novel techniques. METHODS Ultra-high resolution MDCT distal tibia scans were collected at age 19 visits under the Iowa Bone Development Study (IBDS), and cortical and trabecular bone microstructural outcomes were computed at the distal tibia using previously validated methods. CT scans of a tissue characterization phantom were used to calibrate CT numbers (Hounsfield units) into bone mineral density (mg/cc). Period-specific and cumulative F intakes from birth up to the age of 19 years were assessed for IBDS participants through questionnaire, and their relationships with MDCT-derived bone microstructural outcomes were examined using bivariable and multivariable analyses, adjusting for height, weight, maturity offset (years since age of peak height velocity (PHV)), physical activity (questionnaire for adolescents (PAQ-A)), healthy eating index version 2010 (HEI-2010) scores, and calcium and protein intakes. RESULTS MDCT distal tibia scans were acquired for 324 participants from among the total of 329 participants at age 19 visits. No motion artifacts were observed in any MDCT scans, and all images were successfully processed to measure cortical and trabecular bone microstructural outcomes. At early adulthood, males were observed to have stronger trabecular bone microstructural features, as well as thicker cortical bone (p < 0.01), as compared to age-similar females; however, females were found to have less cortical bone porosity as compared to males. Among participants with available F intake estimates (75 to 91% of the 324 with MDCT scans, depending on the period-specific F intake measure), no statistically significant associations were detected between any period-specific or cumulative F intake and bone microstructural outcomes of the tibia at the p < 0.01 level. Only for females, statistically suggestive associations (p < 0.05) were found between recent F intake (from 14 to 19 years) and trabecular mean plate width and trabecular thickness at the tibia. Those associations became somewhat weaker, but still statistically suggestive, for trabecular thickness in fully adjusted analysis with height, weight, PHV, calcium and protein intake, and HEI-2010 and PAQ-A scores as covariates. CONCLUSION The findings show that the effects of lifelong or period-specific F intake from combined sources for adolescents typical to the United States Midwest region are not strongly associated with bone microstructural outcomes at age 19 years. These findings are generally consistent with previously reported results of IBDS analyses, which further confirms that effects of lifelong or period-specific F intake on skeletons in early adulthood are absent or weak, even at the levels of cortical and trabecular bone microstructural details.
Collapse
Affiliation(s)
- Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering, The University of Iowa, Iowa City, IA, USA; Department of Radiology, Carver College of Medicine, The University of Iowa, Iowa City, IA, USA.
| | - Reem Reda Oweis
- Department of Preventive and Community Dentistry, College of Dentistry, Iowa City, IA, USA
| | - Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering, The University of Iowa, Iowa City, IA, USA
| | - Elena Letuchy
- Department of Epidemiology, College of Public Health, Iowa City, IA, USA
| | - Julie M Eichenberger-Gilmore
- Department of Epidemiology, College of Public Health, Iowa City, IA, USA; Formerly with Department of Preventive and Community Dentistry, College of Dentistry, Iowa City, IA, USA; Nutrition and Food Services, Iowa City VA Health Care System, Iowa City, IA, USA
| | - Trudy L Burns
- Department of Epidemiology, College of Public Health, Iowa City, IA, USA
| | - John J Warren
- Department of Preventive and Community Dentistry, College of Dentistry, Iowa City, IA, USA
| | - Kathleen F Janz
- Department of Health and Human Physiology, College of Liberal Arts and Sciences, Iowa City, IA, USA
| | - James C Torner
- Department of Epidemiology, College of Public Health, Iowa City, IA, USA
| | - Linda G Snetselaar
- Department of Epidemiology, College of Public Health, Iowa City, IA, USA
| | - Steven M Levy
- Department of Preventive and Community Dentistry, College of Dentistry, Iowa City, IA, USA; Department of Epidemiology, College of Public Health, Iowa City, IA, USA
| |
Collapse
|
13
|
Zhang X, Comellas AP, Regan EA, Guha I, Shibli-Rahhal A, Rubin MR, DiCamillo PA, Letuchy EM, Barr RG, Hoffman EA, Saha PK. Quantitative CT-Based Methods for Bone Microstructural Measures and Their Relationships With Vertebral Fractures in a Pilot Study on Smokers. JBMR Plus 2021; 5:e10484. [PMID: 33977202 PMCID: PMC8101620 DOI: 10.1002/jbm4.10484] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Accepted: 02/23/2021] [Indexed: 11/05/2022] Open
Abstract
Osteoporosis causes fragile bone, and bone microstructural quality is a critical determinant of bone strength and fracture risk. This study pursues technical validation of novel CT-based methods for assessment of peripheral bone microstructure together with a human pilot study examining relationships between bone microstructure and vertebral fractures in smokers. To examine the accuracy and reproducibility of the methods, repeat ultra-high-resolution (UHR) CT and micro-CT scans of cadaveric ankle specimens were acquired. Thirty smokers from the University of Iowa COPDGene cohort were recruited at their 5-year follow-up visits. Chest CT scans, collected under the parent study, were used to assess vertebral fractures. UHR CT scans of distal tibia were acquired for this pilot study to obtain peripheral cortical and trabecular bone (Cb and Tb) measures. UHR CT-derived Tb measures, including volumetric bone mineral density (BMD), network area, transverse trabecular density, and mean plate width, showed high correlation (r > 0.901) with their micro-CT-derived values over small regions of interest (ROIs). Both Cb and Tb measures showed high reproducibility-intra-class correlation (ICC) was greater than 0.99 for all Tb measures except erosion index and greater than 0.97 for all Cb measures. Female sex was associated with lower transverse Tb density (p < 0.1), higher Tb spacing (p < 0.05), and lower cortical thickness (p < 0.001). Participants with vertebral fractures had significantly degenerated values (p < 0.05) for all Tb measures except thickness. There were no statistically significant differences for Cb measures between non-fracture and fracture groups. Vertebral fracture-group differences of Tb measures remained significant after adjustment with chronic obstructive pulmonary disease (COPD) status. Although current smokers at baseline had more fractures-81.8% versus 63.2% for former smokers-the difference was not statistically significant. This pilot cross-sectional human study demonstrates CT-based peripheral bone microstructural differences among smokers with and without vertebral fractures. © 2021 The Authors. JBMR Plus published by Wiley Periodicals, Inc. on behalf of American Society for Bone and Mineral Research. © 2021 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering University of Iowa Iowa City IA USA
| | - Alejandro P Comellas
- Department of Internal Medicine, Carver College of Medicine University of Iowa Iowa City IA USA
| | - Elizabeth A Regan
- Division of Rheumatology, Department of Medicine National Jewish Health Denver CO USA
| | - Indranil Guha
- Department of Electrical and Computer Engineering, College of Engineering University of Iowa Iowa City IA USA
| | - Amal Shibli-Rahhal
- Department of Internal Medicine, Carver College of Medicine University of Iowa Iowa City IA USA
| | - Mishaela R Rubin
- Department of Clinical Medicine Columbia University New York NY USA
| | - Paul A DiCamillo
- Department of Radiology, Carver College of Medicine University of Iowa Iowa City IA USA
| | - Elena M Letuchy
- Department of Epidemiology, College of Public Health University of Iowa Iowa City IA USA
| | - R Graham Barr
- Department of Medicine Columbia University New York NY USA
| | - Eric A Hoffman
- Department of Radiology, Carver College of Medicine University of Iowa Iowa City IA USA.,Department of Biomedical Engineering, College of Engineering University of Iowa Iowa City IA USA
| | - Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering University of Iowa Iowa City IA USA.,Department of Radiology, Carver College of Medicine University of Iowa Iowa City IA USA
| |
Collapse
|
14
|
Lombardi AF, Tang Q, Wong JH, Williams JL, Jerban S, Ma Y, Jang H, Du J, Chang EY. High-Density Mineralized Protrusions and Central Osteophytes: Associated Osteochondral Junction Abnormalities in Osteoarthritis. Diagnostics (Basel) 2020; 10:diagnostics10121051. [PMID: 33291470 PMCID: PMC7762145 DOI: 10.3390/diagnostics10121051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 11/25/2020] [Accepted: 12/03/2020] [Indexed: 02/05/2023] Open
Abstract
The aim of this study was to determine the association between high-density mineralized protrusions (HDMPs) and central osteophytes (COs), and describe the varying appearance of these lesions using advanced clinical imaging and a novel histological protocol. Seventeen consecutive patients with clinically advanced knee osteoarthritis undergoing knee arthroplasty were included. Surgical tissues containing the osteochondral region were investigated using computed tomography (CT); a subset was evaluated using confocal microscopy with fluorescence. Tissues from seven subjects (41.2%) contained HDMPs, and tissues from seven subjects (41.2%) contained COs. A significant association between HDMPs and COs was present (p = 0.003), with 6 subjects (35.2%) demonstrating both lesions. In total, 30 HDMPs were found, most commonly at the posterior medial femoral condyle (13/30, 43%), and 19 COs were found, most commonly at the trochlea (5/19, 26.3%). The HDMPs had high vascularity at their bases in cartilaginous areas (14/20, 70%), while the surrounding areas had elevated levels of long vascular channels penetrating beyond the zone of calcified cartilage (p = 0.012) compared to HDMP-free areas. Both COs and HDMPs had noticeable bone-resorbing osteoclasts amassing at the osteochondral junction and in vascular channels entering cartilage. In conclusion, HDMPs and COs are associated lesions in patients with advanced knee osteoarthritis, sharing similar histologic features, including increased vascularization and metabolic bone activity at the osteochondral junction. Future studies are needed to determine the relationship of these lesions with osteoarthritis progression and symptomatology.
Collapse
Affiliation(s)
- Alecio F. Lombardi
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
- Department of Radiology, University of California, San Diego, CA 92122, USA
- Correspondence:
| | - Qingbo Tang
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
- Department of Radiology, University of California, San Diego, CA 92122, USA
| | - Jonathan H. Wong
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
- Department of Radiology, University of California, San Diego, CA 92122, USA
| | - Judith L. Williams
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
| | - Saeed Jerban
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
- Department of Radiology, University of California, San Diego, CA 92122, USA
| | - Yajun Ma
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
- Department of Radiology, University of California, San Diego, CA 92122, USA
| | - Hyungseok Jang
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
- Department of Radiology, University of California, San Diego, CA 92122, USA
| | - Jiang Du
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
- Department of Radiology, University of California, San Diego, CA 92122, USA
| | - Eric Y. Chang
- Research Service, VA San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (J.H.W.); (J.L.W.); (S.J.); (Y.M.); (H.J.); (J.D.); (E.Y.C.)
- Department of Radiology, University of California, San Diego, CA 92122, USA
| |
Collapse
|
15
|
Guha I, Klintström B, Klintström E, Zhang X, Smedby Ö, Moreno R, Saha PK. A comparative study of trabecular bone micro-structural measurements using different CT modalities. Phys Med Biol 2020; 65:10.1088/1361-6560/abc367. [PMID: 33086213 PMCID: PMC8058110 DOI: 10.1088/1361-6560/abc367] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 10/21/2020] [Indexed: 01/23/2023]
Abstract
Osteoporosis, characterized by reduced bone mineral density and micro-architectural degeneration, significantly enhances fracture-risk. There are several viable methods for trabecular bone micro-imaging, which widely vary in terms of technology, reconstruction principle, spatial resolution, and acquisition time. We have performed an excised cadaveric bone specimen study to evaluate different computed tomography (CT)-imaging modalities for trabecular bone micro-structural analysis. Excised cadaveric bone specimens from the distal radius were scanned using micro-CT and fourin vivoCT imaging modalities: high-resolution peripheral quantitative computed tomography (HR-pQCT), dental cone beam CT (CBCT), whole-body multi-row detector CT (MDCT), and extremity CBCT. A new algorithm was developed to optimize soft thresholding parameters for individualin vivoCT modalities for computing quantitative bone volume fraction maps. Finally, agreement of trabecular bone micro-structural measures, derived from differentin vivoCT imaging, with reference measures from micro-CT imaging was examined. Observed values of most trabecular measures, including trabecular bone volume, network area, transverse and plate-rod micro-structure, thickness, and spacing, forin vivoCT modalities were higher than their micro-CT-based reference values. In general, HR-pQCT-based trabecular bone measures were closer to their reference values as compared to otherin vivoCT modalities. Despite large differences in observed values of measures among modalities, high linear correlation (rε [0.94 0.99]) was found between micro-CT andin vivoCT-derived measures of trabecular bone volume, transverse and plate micro-structural volume, and network area. All HR-pQCT-derived trabecular measures, except the erosion index, showed high correlation (rε [0.91 0.99]). The plate-width measure showed a higher correlation (rε [0.72 0.91]) amongin vivoand micro-CT modalities than its counterpart binary plate-rod characterization-based measure erosion index (rε [0.65 0.81]). Although a strong correlation was observed between micro-structural measures fromin vivoand micro-CT imaging, large shifts in their values forin vivomodalities warrant proper scanner calibration prior to adopting in multi-site and longitudinal studies.
Collapse
Affiliation(s)
- Indranil Guha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, United States of America
| | - Benjamin Klintström
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Eva Klintström
- Department of Medical and Health Sciences and Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, United States of America
| | - Örjan Smedby
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Rodrigo Moreno
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, United States of America
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA, United States of America
| |
Collapse
|
16
|
Pumberger M, Issever AS, Diekhoff T, Schwemmer C, Berg S, Palmowski Y, Putzier M. Bone structure determined by HR-MDCT does not correlate with micro-CT of lumbar vertebral biopsies: a prospective cross-sectional human in vivo study. J Orthop Surg Res 2020; 15:398. [PMID: 32912263 PMCID: PMC7488144 DOI: 10.1186/s13018-020-01895-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 08/16/2020] [Indexed: 01/22/2023] Open
Abstract
Background Osteoporosis is characterized by a deterioration of bone structure and quantity that leads to an increased risk of fractures. The primary diagnostic tool for the assessment of the bone quality is currently the dual-energy X-ray absorptiometry (DXA), which however only measures bone quantity. High-resolution multidetector computed tomography (HR-MDCT) offers an alternative approach to assess bone structure, but still lacks evidence for its validity in vivo. The objective of this study was to assess the validity of HR-MDCT for the evaluation of bone architecture in the lumbar spine. Methods We conducted a prospective cross-sectional study to compare the results of preoperative lumbar HR-MDCT scans with those from microcomputed tomography (μCT) analysis of transpedicular vertebral body biopsies. For this purpose, we included patients undergoing spinal surgery in our orthopedic department. Each patient underwent preoperative HR-MDCT scanning (L1-L4). Intraoperatively, transpedicular biopsies were obtained from intact vertebrae. Micro-CT analysis of these biopsies was used as a reference method to assess the actual bone architecture. HR-MDCT results were statistically analyzed regarding the correlation with results from μCT. Results Thirty-four patients with a mean age of 69.09 years (± 10.07) were included in the study. There was no significant correlation for any of the parameters (bone volume/total volume, trabecular separation, trabecular thickness) between μCT and HR-MDCT (bone volume/total volume: r = − 0.026 and p = 0.872; trabecular thickness: r = 0.074 and r = 6.42; and trabecular separation: r = − 0.18 and p = 0.254). Conclusion To our knowledge, this is the first study comparing in vivo HR-MDCT with μCT analysis of vertebral biopsies in human patients. Our findings suggest that lumbar HR-MDCT is not valid for the in vivo evaluation of bone architecture in the lumbar spine. New diagnostic tools for the evaluation of osteoporosis and preoperative orthopedic planning are urgently needed.
Collapse
Affiliation(s)
- Matthias Pumberger
- Spine Department, Center for Musculoskeletal Surgery, Charité University Medicine Berlin, Chariteplatz 1, 10117, Berlin, Germany
| | - Ahi Sema Issever
- Department of Radiology, Charité University Medicine Berlin, Chariteplatz 1, 10117, Berlin, Germany
| | - Torsten Diekhoff
- Department of Radiology, Charité University Medicine Berlin, Chariteplatz 1, 10117, Berlin, Germany
| | - Christin Schwemmer
- Charité University Medicine Berlin, Chariteplatz 1, 10117, Berlin, Germany
| | - Susanne Berg
- Charité University Medicine Berlin, Chariteplatz 1, 10117, Berlin, Germany
| | - Yannick Palmowski
- Spine Department, Center for Musculoskeletal Surgery, Charité University Medicine Berlin, Chariteplatz 1, 10117, Berlin, Germany.
| | - Michael Putzier
- Spine Department, Center for Musculoskeletal Surgery, Charité University Medicine Berlin, Chariteplatz 1, 10117, Berlin, Germany
| |
Collapse
|
17
|
Li Y, Samant P, Wang S, Behrooz A, Li D, Xiang L. 3-D X-Ray-Induced Acoustic Computed Tomography With a Spherical Array: A Simulation Study on Bone Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:1613-1619. [PMID: 32286967 PMCID: PMC7394001 DOI: 10.1109/tuffc.2020.2983732] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
X-ray-induced acoustic computed tomography (XACT) is a promising imaging modality combining high X-ray absorption contrast with the 3-D propagation advantages provided by high-resolution ultrasound waves. The purpose of this study was to optimize the configuration of a 3-D XACT imaging system for bone imaging. A 280 ultrasonic sensors with peak frequency of 10 MHz was designed to distribute on a spherical surface to optimize the 3-D volumetric imaging capability. We performed both theoretical calculations and simulations of this optimized XACT imaging configuration on a mouse-sized digital phantom containing various X-ray absorption coefficients. Iteration algorithm based on total variation has been used for 3-D XACT image reconstruction. The spatial resolution of imaging was estimated to about [Formula: see text] along both axial and lateral directions. We simulate XACT imaging of bone microstructures using digital phantoms generated from micro-CT images of real biological samples, showing that XACT imaging can provide high-resolution imaging of the mouse paw. Results of this study will greatly enhance the potential of XACT imaging in the evaluation of bone diseases for future clinical use.
Collapse
Affiliation(s)
- Y. Li
- Shandong Key Laboratory of Medical Physics and Image Processing, Shandong Institute of Industrial Technology for Health Sciences and Precision Medicine, School of Physics and Electronics, Shandong Normal University, Jinan, Shandong 250358, China
| | - P. Samant
- The School of Biomedical Engineering at the University of Oklahoma, Norman, US
| | - S. Wang
- The School of Electrical and Computer Engineering at the University of Oklahoma, Norman, US
| | | | | | | |
Collapse
|
18
|
Richert C, Huber N. A Review of Experimentally Informed Micromechanical Modeling of Nanoporous Metals: From Structural Descriptors to Predictive Structure-Property Relationships. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E3307. [PMID: 32722289 PMCID: PMC7435653 DOI: 10.3390/ma13153307] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 07/17/2020] [Accepted: 07/20/2020] [Indexed: 11/16/2022]
Abstract
Nanoporous metals made by dealloying take the form of macroscopic (mm- or cm-sized) porous bodies with a solid fraction of around 30%. The material exhibits a network structure of "ligaments" with an average ligament diameter that can be adjusted between 5 and 500 nm. Current research explores the use of nanoporous metals as functional materials with respect to electrochemical conversion and storage, bioanalytical and biomedical applications, and actuation and sensing. The mechanical behavior of the network structure provides the scope for fundamental research, particularly because of the high complexity originating from the randomness of the structure and the challenges arising from the nanosized ligaments, which can be accessed through an experiment only indirectly via the testing of the macroscopic properties. The strength of nanoscale ligaments increases systematically with decreasing size, and owing to the high surface-to-volume ratio their elastic and plastic properties can be additionally tuned by applying an electric potential. Therefore, nanoporous metals offer themselves as suitable model systems for exploring the structure-property relationships of complex interconnected microstructures as well as the basic mechanisms of the chemo-electro-mechanical coupling at interfaces. The micromechanical modeling of nanoporous metals is a rapidly growing field that strongly benefits from developments in computational methods, high-performance computing, and visualization techniques; it also benefits at the same time through advances in characterization techniques, including nanotomography, 3D image processing, and algorithms for geometrical and topological analysis. The review article collects articles on the structural characterization and micromechanical modeling of nanoporous metals and discusses the acquired understanding in the context of advancements in the experimental discipline. The concluding remarks are given in the form of a summary and an outline of future perspectives.
Collapse
Affiliation(s)
- Claudia Richert
- Institute of Materials Research, Materials Mechanics, Helmholtz-Zentrum Geesthacht, 21502 Geesthacht, Germany;
| | - Norbert Huber
- Institute of Materials Research, Materials Mechanics, Helmholtz-Zentrum Geesthacht, 21502 Geesthacht, Germany;
- Institute of Materials Physics and Technology, Hamburg University of Technology, 21073 Hamburg, Germany
| |
Collapse
|
19
|
Wani IM, Arora S. Computer-aided diagnosis systems for osteoporosis detection: a comprehensive survey. Med Biol Eng Comput 2020; 58:1873-1917. [PMID: 32583141 DOI: 10.1007/s11517-020-02171-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Accepted: 03/26/2020] [Indexed: 12/18/2022]
Abstract
Computer-aided diagnosis (CAD) has revolutionized the field of medical diagnosis. They assist in improving the treatment potentials and intensify the survival frequency by early diagnosing the diseases in an efficient, timely, and cost-effective way. The automatic segmentation has led the radiologist to successfully segment the region of interest to improve the diagnosis of diseases from medical images which is not so efficiently possible by manual segmentation. The aim of this paper is to survey the vision-based CAD systems especially focusing on the segmentation techniques for the pathological bone disease known as osteoporosis. Osteoporosis is the state of the bones where the mineral density of bones decreases and they become porous, making the bones easily susceptible to fractures by small injury or a fall. The article covers the image acquisition techniques for acquiring the medical images for osteoporosis diagnosis. The article also discusses the advanced machine learning paradigms employed in segmentation for osteoporosis disease. Other image processing steps in osteoporosis like feature extraction and classification are also briefly described. Finally, the paper gives the future directions to improve the osteoporosis diagnosis and presents the proposed architecture. Graphical abstract.
Collapse
Affiliation(s)
- Insha Majeed Wani
- School of Computer Science and Engineering, SMVDU, Katra, J&K, India
| | - Sakshi Arora
- School of Computer Science and Engineering, SMVDU, Katra, J&K, India.
| |
Collapse
|
20
|
Abstract
PURPOSE OF REVIEW Patients with inflammatory arthropathies have a high rate of fragility fractures. Diagnostic assessment and monitoring of bone density and quality are therefore critically important. Here, we review standard and advanced techniques to measure bone density and quality, specifically focusing on patients with inflammatory arthropathies. RECENT FINDINGS Current standard procedures are dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT). DXA-based newer methods include trabecular bone score (TBS) and vertebral fracture assessment (VFA). More advanced imaging methods to measure bone quality include high-resolution peripheral quantitative computed tomography (HR-pQCT) as well as multi-detector CT (MD-CT) and magnetic resonance imaging (MRI). Quantitative ultrasound has shown promise but is not standard to assess bone fragility. While there are limitations, DXA remains the standard technique to measure density in patients with rheumatological disorders. Newer modalities to measure bone quality may allow better characterization of bone fragility but currently are not standard of care procedures.
Collapse
|
21
|
Guha I, Nadeem SA, You C, Zhang X, Levy SM, Wang G, Torner JC, Saha PK. Deep Learning Based High-Resolution Reconstruction of Trabecular Bone Microstructures from Low-Resolution CT Scans using GAN-CIRCLE. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2020; 11317:113170U. [PMID: 32201450 PMCID: PMC7085412 DOI: 10.1117/12.2549318] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Osteoporosis is a common age-related disease characterized by reduced bone density and increased fracture-risk. Microstructural quality of trabecular bone (Tb), commonly found at axial skeletal sites and at the end of long bones, is an important determinant of bone-strength and fracture-risk. High-resolution emerging CT scanners enable in vivo measurement of Tb microstructures at peripheral sites. However, resolution-dependence of microstructural measures and wide resolution-discrepancies among various CT scanners together with rapid upgrades in technology warrant data harmonization in CT-based cross-sectional and longitudinal bone studies. This paper presents a deep learning-based method for high-resolution reconstruction of Tb microstructures from low-resolution CT scans using GAN-CIRCLE. A network was developed and evaluated using post-registered ankle CT scans of nineteen volunteers on both low- and high-resolution CT scanners. 9,000 matching pairs of low- and high-resolution patches of size 64×64 were randomly harvested from ten volunteers for training and validation. Another 5,000 matching pairs of patches from nine other volunteers were used for evaluation. Quantitative comparison shows that predicted high-resolution scans have significantly improved structural similarity index (p < 0.01) with true high-resolution scans as compared to the same metric for low-resolution data. Different Tb microstructural measures such as thickness, spacing, and network area density are also computed from low- and predicted high-resolution images, and compared with the values derived from true high-resolution scans. Thickness and network area measures from predicted images showed higher agreement with true high-resolution CT (CCC = [0.95, 0.91]) derived values than the same measures from low-resolution images (CCC = [0.72, 0.88]).
Collapse
Affiliation(s)
- Indranil Guha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA 52242
| | - Syed Ahmed Nadeem
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA 52242
| | - Chenyu You
- Department of Computer Science, Yale University, New Haven, CT 05620
| | - Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA 52242
| | - Steven M Levy
- Department of Preventive and Community Dentistry, College of Dentistry, University of Iowa, Iowa City, IA 52242
| | - Ge Wang
- Biomedical Imaging Center, BME/CBIS, Rensselaer Polytechnic Institute, Troy, New York, NY 12180
| | - James C Torner
- Department of Epidemiology, University of Iowa, Iowa City, IA 52242
| | - Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA 52242
- Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA 52242
| |
Collapse
|
22
|
Zhang X, Letuchy EM, Levy SM, Torner JC, Saha PK. CT-Based Characterization of Transverse and Longitudinal Trabeculae and Its Applications. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2020; 11317:113171F. [PMID: 32201451 PMCID: PMC7085413 DOI: 10.1117/12.2549881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Osteoporosis is a common age-related disease characterized by reduced bone mineral density (BMD), micro-structural deterioration, and enhanced fracture-risk. Although, BMD is clinically used to define osteoporosis, there are compelling evidences that bone micro-structural properties are strong determinants of bone strength and fracture-risk. Reliable measures of effective trabecular bone (Tb) micro-structural features are of paramount clinical significance. Tb consists of transverse and longitudinal micro-structures, and there is a hypothesis that transverse trabeculae improve bone strength by arresting buckling of longitudinal trabeculae. In this paper, we present an emerging clinical CT-based new method for characterizing transverse and longitudinal trabeculae, validate the method, and examine its application in human studies. Specifically, we examine repeat CT scan reproducibility, and evaluate the relationships of these measures with gender and body size using human CT data from the Iowa Bone Development Study (IBDS) (n = 99; 49 female). Based on a cadaveric ankle study (n = 12), both transverse and longitudinal Tb measures are found reproducible (ICC > 0.94). It was observed in the IBDS human data that males have significantly higher trabecular bone measures than females for both inner (p < 0.05) and outer (p < 0.01) regions of interest (ROIs). For weight, Spearman correlations ranged 0.43-0.48 for inner ROI measures and 0.50-0.52 for outer ROI measures for females versus 0.30-0.34 and 0.23-0.25 for males. Correlation with height was lower (0.36-0.39), but still mostly significant for females. No association of trabecular measures with height was found for males.
Collapse
Affiliation(s)
- Xiaoliu Zhang
- Department of Electrical and Computer Engineering, University of Iowa, USA
| | | | - Steven M Levy
- Department of Preventive and Community Dentistry, University of Iowa, USA
| | | | - Punam K Saha
- Department of Electrical and Computer Engineering, University of Iowa, USA
| |
Collapse
|
23
|
Löffler MT, Sollmann N, Mei K, Valentinitsch A, Noël PB, Kirschke JS, Baum T. X-ray-based quantitative osteoporosis imaging at the spine. Osteoporos Int 2020; 31:233-250. [PMID: 31728606 DOI: 10.1007/s00198-019-05212-2] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Accepted: 10/28/2019] [Indexed: 12/11/2022]
Abstract
Osteoporosis is a metabolic bone disease with a high prevalence that affects the population worldwide, particularly the elderly. It is often due to fractures associated with bone fragility that the diagnosis of osteoporosis becomes clinically evident. However, early diagnosis would be necessary to initiate therapy and to prevent occurrence of further fractures, thus reducing morbidity and mortality. X-ray-based imaging plays a key role for fracture risk assessment and monitoring of osteoporosis. Whereas over decades dual-energy X-ray absorptiometry (DXA) has been the main method used and still reflects the reference standard, another modality reemerges with quantitative computed tomography (QCT) because of its three-dimensional advantages and the opportunistic exploitation of routine CT scans. Against this background, this article intends to review and evaluate recent advances in the field of X-ray-based quantitative imaging of osteoporosis at the spine. First, standard DXA with the recent addition of trabecular bone score (TBS) is presented. Secondly, standard QCT, dual-energy BMD quantification, and opportunistic BMD screening in non-dedicated CT exams are discussed. Lastly, finite element analysis and microstructural parameter analysis are reviewed.
Collapse
Affiliation(s)
- M T Löffler
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
| | - N Sollmann
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - K Mei
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - A Valentinitsch
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - P B Noël
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - J S Kirschke
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - T Baum
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| |
Collapse
|
24
|
Shi G, Subramanian S, Cao Q, Demehri S, Siewerdsen JH, Zbijewski W. Application of a Novel Ultra-High Resolution Multi-Detector CT in Quantitative Imaging of Trabecular Microstructure. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2020; 11317:113171E. [PMID: 33597792 PMCID: PMC7885907 DOI: 10.1117/12.2552385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
PURPOSE To evaluate the performance of a novel ultra-high resolution multi-detector CT scanner (Canon Aquilion Precision UHR CT), capable of visualizing ~150 μm details, in quantitative assessment of bone microarchitecture. Compared to conventional CT, the spatial resolution of UHR CT begins to approach the size of the trabeculae. This might enable measurements of microstructural correlates of osteoporosis, osteoarthritis, and other bone disease. METHODS The UHR CT system features a 160-row x-ray detector with 250×250 μm pixels (measured at isocenter) and a custom-designed x-ray source with a 0.4×0.5 mm focal spot. Visualization of high contrast details down to ~150 μm has been achieved on this device, which is now commercially available for clinical use. To evaluate the performance of UHR CT in quantification of bone microstructure, we imaged a variety of human bone samples (including ulna, radius, and vertebrae) embedded in a ~16 cm diameter plastic cylinder and in an anthropomorphic thorax phantom (QRM-Thorax, QRM Gmbh). Helical UHR CT acquisitions (120 kVp tube voltage) were acquired at scan exposures of 375 mAs - 5 mAs. For comparison, the samples were also imaged using a Normal Resolution (NR) mode available on the scanner, involving 500 μm slice thickness, exposure of 50 mAs, and a focal spot of 0.6×1.3 mm. We obtained micro-CT (μCT) of the bone samples at ~28 μm voxel size as a gold-standard reference. Geometric measurements of bone microstructure were performed in 17 regions-of-interests (ROIs) distributed throughout the bones of the phantoms; image registration was used to place the ROIs at corresponding locations in the UHR CT and NR CT. Trabecular thickness Tb.Th, spacing Tb.Sp, and Bone Volume fraction BvTv were obtained. The UHR and NR imaging protocols were compared terms of correlations to μCT and error of trabecular measurements. The effect of dose on trabecular morphometry was also studied for the UHR CT. Furthermore, we evaluated the sensitivity of texture features of trabecular bone (recently proposed as an alternative to geometric indices of microstructure) to imaging protocol. Image texture evaluation was performed using ~150 regions of interest (ROIs) across all bone samples. Three-dimensional Gray Level Co-occurrence Matrix (GLCM) and Gray Level Run Length Matrix (GLRM) features were extracted for each ROI. We analyzed correlation and concordance correlation coefficient (CCC) of the mean ROI values of texture features obtained using the UHR and NR modes. RESULTS UHR CT reconstructions of bone samples clearly demonstrated improved visualization of the trabeculae compared to NR CT. UHR CT achieved substantially better correlations for all three metrics of bone microstructure, in particular for BvTv (correlation coefficient of 0.91 for UHR CT compared to 0.84 for NR CT) and TbSp (correlation of 0.74 for UHR CT and 0.047 for NR CT). The error obtained with UHR CT was generally smaller than that of NR CT. For TbSp, the mean deviation from μCT (averaged across all bone samples) was only ~0.07 for UHR CT, compared to 0.25 for NR CT. Analysis of reproducibility of texture features of trabecular bone between UHR CT and NR CT revealed fair correlations (>0.7) for the majority of GLCM features, but relatively poor CCC (e.g. 0.02 for Energy and 0.04 for Entropy). The magnitude of texture metrics is particularly affected by the enhanced spatial resolution of UHR CT. CONCLUSION The recently introduced UHR CT achieves improved correlation and reduced error in measurements of trabecular bone microstructure compared to conventional resolution CT. Future development of diagnostic strategies based on textural biomarkers derived from UHR CT will need to account for potential sensitivity of texture features to image resolution.
Collapse
Affiliation(s)
- G Shi
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205
| | - S Subramanian
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205
| | - Q Cao
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205
| | - S Demehri
- Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, MD USA 21287
| | - J H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205
- Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, MD USA 21287
| | - W Zbijewski
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD USA 21205
| |
Collapse
|
25
|
You C, Li G, Zhang Y, Zhang X, Shan H, Li M, Ju S, Zhao Z, Zhang Z, Cong W, Vannier MW, Saha PK, Hoffman EA, Wang G. CT Super-Resolution GAN Constrained by the Identical, Residual, and Cycle Learning Ensemble (GAN-CIRCLE). IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:188-203. [PMID: 31217097 DOI: 10.1109/tmi.2019.2922960] [Citation(s) in RCA: 164] [Impact Index Per Article: 41.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
In this paper, we present a semi-supervised deep learning approach to accurately recover high-resolution (HR) CT images from low-resolution (LR) counterparts. Specifically, with the generative adversarial network (GAN) as the building block, we enforce the cycle-consistency in terms of the Wasserstein distance to establish a nonlinear end-to-end mapping from noisy LR input images to denoised and deblurred HR outputs. We also include the joint constraints in the loss function to facilitate structural preservation. In this process, we incorporate deep convolutional neural network (CNN), residual learning, and network in network techniques for feature extraction and restoration. In contrast to the current trend of increasing network depth and complexity to boost the imaging performance, we apply a parallel 1×1 CNN to compress the output of the hidden layer and optimize the number of layers and the number of filters for each convolutional layer. The quantitative and qualitative evaluative results demonstrate that our proposed model is accurate, efficient and robust for super-resolution (SR) image restoration from noisy LR input images. In particular, we validate our composite SR networks on three large-scale CT datasets, and obtain promising results as compared to the other state-of-the-art methods.
Collapse
|
26
|
Quantifying Subresolution 3D Morphology of Bone with Clinical Computed Tomography. Ann Biomed Eng 2019; 48:595-605. [PMID: 31583552 PMCID: PMC6949315 DOI: 10.1007/s10439-019-02374-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Accepted: 09/24/2019] [Indexed: 01/10/2023]
Abstract
The aim of this study was to quantify sub-resolution trabecular bone morphometrics, which are also related to osteoarthritis (OA), from clinical resolution cone beam computed tomography (CBCT). Samples (n = 53) were harvested from human tibiae (N = 4) and femora (N = 7). Grey-level co-occurrence matrix (GLCM) texture and histogram-based parameters were calculated from CBCT imaged trabecular bone data, and compared with the morphometric parameters quantified from micro-computed tomography. As a reference for OA severity, histological sections were subjected to OARSI histopathological grading. GLCM and histogram parameters were correlated to bone morphometrics and OARSI individually. Furthermore, a statistical model of combined GLCM/histogram parameters was generated to estimate the bone morphometrics. Several individual histogram and GLCM parameters had strong associations with various bone morphometrics (|r| > 0.7). The most prominent correlation was observed between the histogram mean and bone volume fraction (r = 0.907). The statistical model combining GLCM and histogram-parameters resulted in even better association with bone volume fraction determined from CBCT data (adjusted R2 change = 0.047). Histopathology showed mainly moderate associations with bone morphometrics (|r| > 0.4). In conclusion, we demonstrated that GLCM- and histogram-based parameters from CBCT imaged trabecular bone (ex vivo) are associated with sub-resolution morphometrics. Our results suggest that sub-resolution morphometrics can be estimated from clinical CBCT images, associations becoming even stronger when combining histogram and GLCM-based parameters.
Collapse
|
27
|
Ding J, Xu X, Wu X, Huang Z, Kong G, Liu J, Huang Z, Liu Q, Li R, Yang Z, Liu Y, Zhu Q. Bone loss and biomechanical reduction of appendicular and axial bones under ketogenic diet in rats. Exp Ther Med 2019; 17:2503-2510. [PMID: 30906438 PMCID: PMC6425126 DOI: 10.3892/etm.2019.7241] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Accepted: 12/13/2018] [Indexed: 12/12/2022] Open
Abstract
A ketogenic diet (KD) is composed of low-carbohydrate, high-fat and adequate levels of protein. It has been used for decades as a method to treat pediatric refractory epilepsy. However, recently, its side effects on the bones have received increasing attention. In order to comprehensively evaluate the effect of KD on the microstructures and mechanical properties of the skeleton, 14 male Sprague-Dawley rats were equally divided into two groups and fed with a KD (ratio of fat to carbohydrate and protein, 3:1) or a standard diet for 12 weeks. Body weight, as well as blood ketone and glucose levels, were monitored during the experiment. Bone morphometric analyses via micro-computerized tomography were performed on cortical and trabecular bone at the middle L4 vertebral body, the proximal humerus and tibia. The compressive stiffness and strength of scanned skeletal areas were calculated using micro-finite element analysis. The KD led to higher ketone levels and lower glucose levels, with reduced body weight and total bone mineral density (TBMD). After 12 weeks, the diet reduced the bone volume fraction, the trabecular number of cancellous bone, cortical thickness, total cross-sectional area inside the periosteal envelope and the bone area of cortical bone in the tibia and humerus, while increasing trabecular separation. However, KD may not affect the L4 vertebral body. The serum calcium or phosphate concentrations in the blood remained unchanged. In addition, bone stiffness and strength were clearly decreased by the KD, and significantly correlated with the BMD and bone area at all scanned sites. In conclusion, KD led to significant bone loss and reduced biomechanical function in appendicular bones, with a lesser impact on axial bones.
Collapse
Affiliation(s)
- Jianyang Ding
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Xiaolin Xu
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Xiuhua Wu
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Zucheng Huang
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Ganggang Kong
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Junhao Liu
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Zhiping Huang
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Qi Liu
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Rong Li
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Zhou Yang
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Yapu Liu
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Qingan Zhu
- Department of Spine Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| |
Collapse
|
28
|
Areeckal AS, Kocher M, S SD. Current and Emerging Diagnostic Imaging-Based Techniques for Assessment of Osteoporosis and Fracture Risk. IEEE Rev Biomed Eng 2018; 12:254-268. [PMID: 29994405 DOI: 10.1109/rbme.2018.2852620] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Osteoporosis is a metabolic bone disorder characterized by low bone mass, degradation of bone microarchitecture, and susceptibility to fracture. It is a growing major health concern across the world, especially in the elderly population. Osteoporosis can cause hip or spinal fractures that may lead to high morbidity and socio-economic burden. Therefore, there is a need for early diagnosis of osteoporosis and prediction of fragility fracture risk. In this review, state of the art and recent advances in imaging techniques for diagnosis of osteoporosis and fracture risk assessment have been explored. Segmentation methods used to segment the regions of interest and texture analysis methods used for classification of healthy and osteoporotic subjects are also presented. Furthermore, challenges posed by the current diagnostic tools have been studied and feasible solutions to circumvent the limitations are discussed. Early diagnosis of osteoporosis and prediction of fracture risk require the development of highly precise and accurate low-cost diagnostic techniques that would help the elderly population in low economies.
Collapse
|
29
|
West SL, Rajapakse CS, Rayner T, Miller R, Slinger MA, Wells GD. The reproducibility of measuring trabecular bone parameters using a commercially available high-resolution magnetic resonance imaging approach: A pilot study. Bone Rep 2018; 8:180-186. [PMID: 29955637 PMCID: PMC6020268 DOI: 10.1016/j.bonr.2018.04.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 04/09/2018] [Accepted: 04/23/2018] [Indexed: 02/02/2023] Open
Abstract
Bone imaging is currently the best non-invasive way to assess changes to bone associated with aging or chronic disease. However, common imaging techniques such as dual energy x-ray absorptiometry are associated with limitations. Magnetic resonance imaging (MRI) is a radiation-free technique that can measure bone microarchitecture. However, published MRI bone assessment protocols use specialized MRI coils and sequences and therefore have limited transferability across institutions. We developed a protocol on a Siemens 3 Tesla MRI machine, using a commercially available coil (Siemens 15 CH knee coil), and manufacturer supplied sequences to acquire images at the tibia. We tested the reproducibility of the FSE and the GE Axial sequences and hypothesized that both would generate reproducible trabecular bone parameters. Eight healthy adults (age 25.5 ± 5.4 years) completed three measurements of each MRI sequence at the tibia. Each of the images was processed for 8 different bone parameters (such as volumetric bone volume fraction). We computed the coefficient of variation (CV) and intraclass correlation coefficients (ICC) to assess reproducibility and reliability. Both sequences resulted in trabecular parameters that were reproducible (CV <5% for most) and reliable (ICC >80% for all). Our study is one of the first to report that a commercially available MRI protocol can result in reproducible data, and is significant as MRI may be an accessible method to measure bone microarchitecture in clinical or research environments. This technique requires further testing, including validation and evaluation in other populations. Trabecular bone is difficult to measure using commercial MRI techniques Reproducibility of a MRI protocol measuring trabecular bone was assessed Tibia trabecular bone was reproducible using a knee coil and a FSE Axial sequence Tibia trabecular bone was reproducible using a knee coil and a GE Axial sequence
Collapse
Affiliation(s)
- Sarah L West
- Department of Biology, Trent/Fleming School of Nursing, Trent University, Peterborough, Ontario, Canada.,Translational Medicine, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Chamith S Rajapakse
- Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA.,Department of Orthopaedic Surgery, University of Pennsylvania School of Medicine, Philadelphia, PA, USA
| | - Tammy Rayner
- Radiology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Rhiannon Miller
- Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA.,Department of Orthopaedic Surgery, University of Pennsylvania School of Medicine, Philadelphia, PA, USA
| | - Michelle A Slinger
- Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA.,Department of Orthopaedic Surgery, University of Pennsylvania School of Medicine, Philadelphia, PA, USA
| | - Greg D Wells
- Translational Medicine, The Hospital for Sick Children, Toronto, Ontario, Canada.,Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|