Krishnamurthy LC, Liu P, Xu F, Uh J, Dimitrov I, Lu H. Dependence of blood T(2) on oxygenation at 7 T: in vitro calibration and in vivo application.
Magn Reson Med 2013;
71:2035-42. [PMID:
23843129 DOI:
10.1002/mrm.24868]
[Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2013] [Revised: 05/23/2013] [Accepted: 06/12/2013] [Indexed: 01/15/2023]
Abstract
PURPOSE
The calibratable relationship between blood oxygenation (Y) and T(2) allows quantification of cerebral venous oxygenation. We aim to establish a calibration plot between blood T(2) , Y, and hematocrit at 7 T, and using T(2) -relaxation-under-spin-tagging MRI, determine human venous blood oxygenation in vivo.
METHODS
In vitro experiments were performed at 7 T on bovine blood samples using a Carr-Purcell-Meiboom-Gill-T2 sequence, from which we characterized the relationship among T(2) , Y, and hematocrit. T(2) -relaxation-under-spin-tagging MRI was implemented at 7 T to measure venous blood T2 in vivo, from which oxygenation was estimated using the in vitro calibration plot. Hyperoxia was performed to test the sensitivity of the method to oxygenation changes, and the 7 T results were compared with those at 3 T.
RESULTS
In vitro data showed that arterial and venous T(2) at 7 T are 68 and 20 ms, respectively, at a typical hematocrit of 0.42. In vivo measurement showed a cerebral venous oxygenation of 64.7 ± 5.0% and a test-retest coefficient-of-variation of 3.6 ± 2.4%. Hyperoxia increased Yv by 9.0 ± 1.4% (P = 0.001) and the 3 and 7 T results showed a strong correlation (R = 0.95) across individuals.
CONCLUSION
We provided an in vitro calibration plot for conversion of blood T(2) to oxygenation at 7 T and demonstrated its utility in vivo.
Collapse