Keum H, Cevik E, Kim J, Demirlenk YM, Atar D, Saini G, Sheth RA, Deipolyi AR, Oklu R. Tissue Ablation: Applications and Perspectives. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2310856. [PMID: 38771628 PMCID: PMC11309902 DOI: 10.1002/adma.202310856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 05/05/2024] [Indexed: 05/22/2024]
Abstract
Tissue ablation techniques have emerged as a critical component of modern medical practice and biomedical research, offering versatile solutions for treating various diseases and disorders. Percutaneous ablation is minimally invasive and offers numerous advantages over traditional surgery, such as shorter recovery times, reduced hospital stays, and decreased healthcare costs. Intra-procedural imaging during ablation also allows precise visualization of the treated tissue while minimizing injury to the surrounding normal tissues, reducing the risk of complications. Here, the mechanisms of tissue ablation and innovative energy delivery systems are explored, highlighting recent advancements that have reshaped the landscape of clinical practice. Current clinical challenges related to tissue ablation are also discussed, underlining unmet clinical needs for more advanced material-based approaches to improve the delivery of energy and pharmacology-based therapeutics.
Collapse
Affiliation(s)
- Hyeongseop Keum
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Enes Cevik
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Jinjoo Kim
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Yusuf M Demirlenk
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Dila Atar
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Gia Saini
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Rahul A Sheth
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, Houston, Texas 77030, USA
| | - Amy R Deipolyi
- Interventional Radiology, Department of Surgery, West Virginia University, Charleston Area Medical Center, Charleston, WV 25304, USA
| | - Rahmi Oklu
- Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
- Division of Vascular & Interventional Radiology, Mayo Clinic, 5777 E Mayo Blvd, Phoenix, Arizona 85054, USA
| |
Collapse
|
2
|
Martínez-Fernández R. Focused ultrasound brain therapy is a new tool in the box. Nat Rev Neurol 2024; 20:443-444. [PMID: 38951598 DOI: 10.1038/s41582-024-00975-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/03/2024]
Affiliation(s)
- Raúl Martínez-Fernández
- HM CINAC, Hospital Universitario HM Puerta del Sur, HM Hospitales, Madrid, Spain.
- Instituto de Investigación Sanitaria HM Hospitales, Madrid, Spain.
- CIBERNED, Instituto de Salud Carlos III, Madrid, Spain.
| |
Collapse
|
3
|
Antoniou A, Evripidou N, Damianou C. Focused ultrasound heating in brain tissue/skull phantoms with 1 MHz single-element transducer. J Ultrasound 2024; 27:263-274. [PMID: 37517052 PMCID: PMC11178743 DOI: 10.1007/s40477-023-00810-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 07/09/2023] [Indexed: 08/01/2023] Open
Abstract
PURPOSE The study aims to provide insights on the practicality of using single-element transducers for transcranial Focused Ultrasound (tFUS) thermal applications. METHODS FUS sonications were performed through skull phantoms embedding agar-based tissue mimicking gels using a 1 MHz single-element spherically focused transducer. The skull phantoms were 3D printed with Acrylonitrile Butadiene Styrene (ABS) and Resin thermoplastics having the exact skull bone geometry of a healthy volunteer. The temperature field distribution during and after heating was monitored in a 3 T Magnetic Resonance Imaging (MRI) scanner using MR thermometry. The effect of the skull's thickness on intracranial heating was investigated. RESULTS A single FUS sonication at focal acoustic intensities close to 1580 W/cm2 for 60 s in free field heated up the agar phantom to ablative temperatures reaching about 90 °C (baseline of 37 °C). The ABS skull strongly blocked the ultrasonic waves, resulting in zero temperature increase within the phantom. Considerable heating was achieved through the Resin skull, but it remained at hyperthermia levels. Conversely, tFUS through a 1 mm Resin skull showed enhanced ultrasonic penetration and heating, with the focal temperature reaching 70 °C. CONCLUSIONS The ABS skull demonstrated poorer performance in terms of tFUS compared to the Resin skull owing to its higher ultrasonic attenuation and porosity. The thin Resin phantom of 1 mm thickness provided an efficient acoustic window for delivering tFUS and heating up deep phantom areas. The results of such studies could be particularly useful for accelerating the establishment of a wider range of tFUS applications.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus.
| |
Collapse
|
4
|
Natera-Villalba E, Ruiz-Yanzi MA, Gasca-Salas C, Matarazzo M, Martínez-Fernández R. MR-guided focused ultrasound in movement disorders and beyond: Lessons learned and new frontiers. Parkinsonism Relat Disord 2024; 122:106040. [PMID: 38378311 DOI: 10.1016/j.parkreldis.2024.106040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 02/09/2024] [Indexed: 02/22/2024]
Abstract
The development of MR-guided focused ultrasound (MRgFUS) has provided a new therapeutic tool for neuropsychiatric disorders. In contrast to previously available neurosurgical techniques, MRgFUS allows precise impact on deep brain structures without the need for incision and yields an immediate effect. In its high-intensity modality (MRgHIFU), it produces accurate therapeutic thermoablation in previously selected brain targets. Importantly, the production of the lesion is progressive and highly controlled in real-time by both neuroimaging and clinical means. MRgHIFU ablation is already an accepted and widely used treatment for medically-refractory Parkinson's disease and essential tremor. Notably, other neurological disorders and diverse brain targets, including bilateral treatments, are currently under examination. Conversely, the low-intensity modality (MRgLIFU) shows promising prospects in neuromodulation and transient blood-brain barrier opening (BBBO). In the former circumstance, MRgLIFU could serve as a powerful clinical and research tool for non-invasively modulating brain activity and function. BBBO, on the other hand, emerges as a potentially impactful method to influence disease pathogenesis and progression by increasing brain target engagement of putative therapeutic agents. While promising, these applications remain experimental. As a recently developed technology, MRgFUS is not without challenges and questions to be addressed. Further developments and broader experience are necessary to enhance MRgFUS capabilities in both research and clinical practice, as well as to define device constraints. This clinical mini-review aims to provide an overview of the main evidence of MRgFUS application and to highlight unmet needs and future potentialities of the technique.
Collapse
Affiliation(s)
- Elena Natera-Villalba
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta Del Sur, HM Hospitales, Madrid, Spain; PhD Medicine Program, Universidad Autónoma de Madrid, Madrid, Spain
| | - María-Agustina Ruiz-Yanzi
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta Del Sur, HM Hospitales, Madrid, Spain
| | - Carmen Gasca-Salas
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta Del Sur, HM Hospitales, Madrid, Spain; CIBERNED, Instituto Carlos III, Madrid, Spain; University CEU-San Pablo, Madrid, Spain
| | - Michele Matarazzo
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta Del Sur, HM Hospitales, Madrid, Spain; CIBERNED, Instituto Carlos III, Madrid, Spain
| | - Raúl Martínez-Fernández
- HM CINAC (Centro Integral de Neurociencias Abarca Campal), Hospital Universitario HM Puerta Del Sur, HM Hospitales, Madrid, Spain; CIBERNED, Instituto Carlos III, Madrid, Spain; University CEU-San Pablo, Madrid, Spain.
| |
Collapse
|
5
|
Thavarajasingam SG, Kilgallon JL, Ramsay DSC, Aval LM, Tewarie IA, Kramer A, Van Vuurden D, Broekman MLD. Methodological and ethical challenges in the use of focused ultrasound for blood-brain barrier disruption in neuro-oncology. Acta Neurochir (Wien) 2023; 165:4259-4277. [PMID: 37672093 PMCID: PMC10739192 DOI: 10.1007/s00701-023-05782-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Accepted: 08/26/2023] [Indexed: 09/07/2023]
Abstract
BACKGROUND Focused ultrasound (FUS) shows promise for enhancing drug delivery to the brain by temporarily opening the blood-brain barrier (BBB), and it is increasingly used in the clinical setting to treat brain tumours. It remains however unclear whether FUS is being introduced in an ethically and methodologically sound manner. The IDEAL-D framework for the introduction of surgical innovations and the SYRCLE and ROBINS-I tools for assessing the risk of bias in animal studies and non-randomized trials, respectively, provide a comprehensive evaluation for this. OBJECTIVES AND METHODS A comprehensive literature review on FUS in neuro-oncology was conducted. Subsequently, the included studies were evaluated using the IDEAL-D framework, SYRCLE, and ROBINS-I tools. RESULTS In total, 19 published studies and 12 registered trials were identified. FUS demonstrated successful BBB disruption, increased drug delivery, and improved survival rates. However, the SYRCLE analysis revealed a high risk of bias in animal studies, while the ROBINS-I analysis found that most human studies had a high risk of bias due to a lack of blinding and heterogeneous samples. Of the 15 pre-clinical stage 0 studies, only six had formal ethical approval, and only five followed animal care policies. Both stage 1 studies and stage 1/2a studies failed to provide information on patient data confidentiality. Overall, no animal or human study reached the IDEAL-D stage endpoint. CONCLUSION FUS holds promise for enhancing drug delivery to the brain, but its development and implementation must adhere to rigorous safety standards using the established ethical and methodological frameworks. The complementary use of IDEAL-D, SYRCLE, and ROBINS-I tools indicates a high risk of bias and ethical limitations in both animal and human studies, highlighting the need for further improvements in study design for a safe implementation of FUS in neuro-oncology.
Collapse
Affiliation(s)
- Santhosh G Thavarajasingam
- Computational Neurosciences Outcomes Center, Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
- Faculty of Medicine, Imperial College London, London, UK.
- Imperial Brain and Spine Initiative, Imperial College London, London, UK.
- Department of Neurosurgery, University Medical Centre Mainz, Mainz, Germany.
| | - John L Kilgallon
- Computational Neurosciences Outcomes Center, Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Daniele S C Ramsay
- Faculty of Medicine, Imperial College London, London, UK
- Imperial Brain and Spine Initiative, Imperial College London, London, UK
| | - Leila Motedayen Aval
- Faculty of Medicine, Imperial College London, London, UK
- Imperial Brain and Spine Initiative, Imperial College London, London, UK
| | - Ishaan Ashwini Tewarie
- Computational Neurosciences Outcomes Center, Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
- Department of Neurosurgery, Haaglanden Medical Center, The Hague, Netherlands
| | - Andreas Kramer
- Department of Neurosurgery, University Medical Centre Mainz, Mainz, Germany
| | | | - Marike L D Broekman
- Department of Neurosurgery, Haaglanden Medical Center, The Hague, Netherlands
- Department of Neurosurgery, Leiden Medical Center, Leiden, Netherlands
| |
Collapse
|
6
|
Yeats E, Hall TL. Aberration correction in abdominal histotripsy. Int J Hyperthermia 2023; 40:2266594. [PMID: 37813397 PMCID: PMC10637766 DOI: 10.1080/02656736.2023.2266594] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 09/28/2023] [Indexed: 10/11/2023] Open
Abstract
In transabdominal histotripsy, ultrasound pulses are focused on the body to noninvasively destroy soft tissues via cavitation. However, the ability to focus is limited by phase aberration, or decorrelation of the ultrasound pulses due to spatial variation in the speed of sound throughout heterogeneous tissue. Phase aberration shifts, broadens, and weakens the focus, thereby reducing the safety and efficacy of histotripsy therapy. This paper reviews and discusses aberration effects in histotripsy and in related therapeutic ultrasound techniques (e.g., high intensity focused ultrasound), with an emphasis on aberration by soft tissues. Methods for aberration correction are reviewed and can be classified into two groups: model-based methods, which use segmented images of the tissue as input to an acoustic propagation model to predict and compensate phase differences, and signal-based methods, which use a receive-capable therapy array to detect phase differences by sensing acoustic signals backpropagating from the focus. The relative advantages and disadvantages of both groups of methods are discussed. Importantly, model-based methods can correct focal shift, while signal-based methods can restore substantial focal pressure, suggesting that both methods should be combined in a 2-step approach. Aberration correction will be critical to improving histotripsy treatments and expanding the histotripsy treatment envelope to enable non-invasive, non-thermal histotripsy therapy for more patients.
Collapse
Affiliation(s)
- Ellen Yeats
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, United States
| | - Timothy L. Hall
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, United States
| |
Collapse
|
7
|
He X, Oshino S, Hosomi K, Kanemoto M, Tani N, Kishima H. Characteristics of Pain During MRI-Guided Focused Ultrasound Thalamotomy. Neurosurgery 2023; 93:358-365. [PMID: 36861986 PMCID: PMC10319367 DOI: 10.1227/neu.0000000000002420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 12/22/2022] [Indexed: 03/03/2023] Open
Abstract
BACKGROUND Magnetic resonance imaging-guided focused ultrasound (MRgFUS) has become popular as an incisionless mode of neurosurgical treatment. However, head pain during sonication is common and its pathophysiology remains poorly understood. OBJECTIVE To explore the characteristics of head pain occurring during MRgFUS thalamotomy. METHODS Our study comprised 59 patients who answered questions about the pain they experienced during unilateral MRgFUS thalamotomy. The location and features of pain were investigated using a questionnaire including the numerical rating scale (NRS) to estimate maximum pain intensity and the Japanese version of the Short Form of McGill Pain Questionnaire 2 to evaluate the quantitative and qualitative dimensions of pain. Several clinical factors were investigated for possible correlation with pain intensity. RESULTS Forty-eight patients (81%) reported sonication-related head pain, and the degree of pain was severe (NRS score ≥ 7) in 39 patients (66%). The distribution of sonication-related pain was "localized" in 29 (49%) and "diffuse" in 16 (27%); the most frequent location was the "occipital" region. The pain features most frequently reported were those in the "affective" subscale of the Short Form of McGill Pain Questionnaire 2. Patients with diffuse pain had a higher NRS score and lower skull density ratio than did patients with localized pain. The NRS score negatively correlated with tremor improvement at 6 months post-treatment. CONCLUSION Most patients in our cohort experienced pain during MRgFUS. The distribution and intensity of pain varied according to the skull density ratio, indicating that the pain might have had different origins. Our results may contribute to the improvement of pain management during MRgFUS.
Collapse
Affiliation(s)
- Xin He
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Satoru Oshino
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Koichi Hosomi
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Manabu Kanemoto
- Department of Neurosurgery, Saito Yukoukai Hospital, Ibaraki, Osaka, Japan
| | - Naoki Tani
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Haruhiko Kishima
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| |
Collapse
|
8
|
Ferreira Felloni Borges Y, Cheyuo C, Lozano AM, Fasano A. Essential Tremor - Deep Brain Stimulation vs. Focused Ultrasound. Expert Rev Neurother 2023; 23:603-619. [PMID: 37288812 DOI: 10.1080/14737175.2023.2221789] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 06/01/2023] [Indexed: 06/09/2023]
Abstract
INTRODUCTION Essential Tremor (ET) is one of the most common tremor syndromes typically presented as action tremor, affecting mainly the upper limbs. In at least 30-50% of patients, tremor interferes with quality of life, does not respond to first-line therapies and/or intolerable adverse effects may occur. Therefore, surgery may be considered. AREAS COVERED In this review, the authors discuss and compare unilateral ventral intermedius nucleus deep brain stimulation (VIM DBS) and bilateral DBS with Magnetic Resonance-guided Focused Ultrasound (MRgFUS) thalamotomy, which comprises focused acoustic energy generating ablation under real-time MRI guidance. Discussion includes their impact on tremor reduction and their potential complications. Finally, the authors provide their expert opinion. EXPERT OPINION DBS is adjustable, potentially reversible and allows bilateral treatments; however, it is invasive requires hardware implantation, and has higher surgical risks. Instead, MRgFUS is less invasive, less expensive, and requires no hardware maintenance. Beyond these technical differences, the decision should also involve the patient, family, and caregivers.
Collapse
Affiliation(s)
- Yuri Ferreira Felloni Borges
- Edmond J. Safra Program in Parkinson's Disease, Division of Neurology, Morton and Gloria Shulman Movement Disorders Clinic, Toronto Western Hospital, UHN, University of Toronto, Toronto, ON, Canada
| | - Cletus Cheyuo
- Division of Neurosurgery, Toronto Western Hospital, University Health Network, Toronto, ON, Canada
| | - Andres M Lozano
- Division of Neurosurgery, Toronto Western Hospital, University Health Network, Toronto, ON, Canada
- Krembil Brain Institute, Toronto, ON, Canada
| | - Alfonso Fasano
- Edmond J. Safra Program in Parkinson's Disease, Division of Neurology, Morton and Gloria Shulman Movement Disorders Clinic, Toronto Western Hospital, UHN, University of Toronto, Toronto, ON, Canada
- Krembil Brain Institute, Toronto, ON, Canada
- Center for Advancing Neurotechnological Innovation to Application (CRANIA), Toronto, ON, Canada
- Department of Parkinson's Disease & Movement Disorders Rehabilitation, Moriggia-Pelascini Hospital, Gravedona Ed Uniti, Como, Italy
| |
Collapse
|
9
|
Hughes A, Khan DS, Alkins R. Current and Emerging Systems for Focused Ultrasound-Mediated Blood-Brain Barrier Opening. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1479-1490. [PMID: 37100672 DOI: 10.1016/j.ultrasmedbio.2023.02.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 02/09/2023] [Accepted: 02/23/2023] [Indexed: 05/17/2023]
Abstract
With an ever-growing list of neurological applications of focused ultrasound (FUS), there has been a consequent increase in the variety of systems for delivering ultrasound energy to the brain. Specifically, recent successful pilot clinical trials of blood-brain barrier (BBB) opening with FUS have generated substantial interest in the future applications of this relatively novel therapy, with divergent, purpose-built technologies emerging. With many of these technologies at various stages of pre-clinical and clinical investigation, this article seeks to provide an overview and analysis of the numerous medical devices in active use and under development for FUS-mediated BBB opening.
Collapse
Affiliation(s)
- Alec Hughes
- School of Medicine, Faculty of Health Sciences, Queen's University, Kingston, ON, Canada
| | - Dure S Khan
- Centre for Neuroscience Studies, Queen's University, Kingston, ON, Canada
| | - Ryan Alkins
- Centre for Neuroscience Studies, Queen's University, Kingston, ON, Canada; Division of Neurosurgery, Department of Surgery, Kingston Health Sciences Centre, Queen's University, Kingston, ON, Canada.
| |
Collapse
|
10
|
Mehkri Y, Pierre K, Woodford SJ, Davidson CG, Urhie O, Sriram S, Hernandez J, Hanna C, Lucke-Wold B. Surgical Management of Brain Tumors with Focused Ultrasound. Curr Oncol 2023; 30:4990-5002. [PMID: 37232835 DOI: 10.3390/curroncol30050377] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 04/26/2023] [Accepted: 05/02/2023] [Indexed: 05/27/2023] Open
Abstract
Focused ultrasound is a novel technique for the treatment of aggressive brain tumors that uses both mechanical and thermal mechanisms. This non-invasive technique can allow for both the thermal ablation of inoperable tumors and the delivery of chemotherapy and immunotherapy while minimizing the risk of infection and shortening the time to recovery. With recent advances, focused ultrasound has been increasingly effective for larger tumors without the need for a craniotomy and can be used with minimal surrounding soft tissue damage. Treatment efficacy is dependent on multiple variables, including blood-brain barrier permeability, patient anatomical features, and tumor-specific features. Currently, many clinical trials are currently underway for the treatment of non-neoplastic cranial pathologies and other non-cranial malignancies. In this article, we review the current state of surgical management of brain tumors using focused ultrasound.
Collapse
Affiliation(s)
- Yusuf Mehkri
- Department of Neurosurgery, College of Medicine, University of Florida, 1505 SW Archer Rd, Gainesville, FL 32608, USA
| | - Kevin Pierre
- Department of Radiology, College of Medicine, University of Florida, 1600 SW Archer Rd, Gainesville, FL 32608, USA
| | - Samuel Joel Woodford
- Department of Neurosurgery, College of Medicine, University of Florida, 1505 SW Archer Rd, Gainesville, FL 32608, USA
| | - Caroline Grace Davidson
- Department of Neurosurgery, College of Medicine, University of Florida, 1505 SW Archer Rd, Gainesville, FL 32608, USA
| | - Ogaga Urhie
- Department of Neurosurgery, College of Medicine, University of Florida, 1505 SW Archer Rd, Gainesville, FL 32608, USA
| | - Sai Sriram
- Department of Neurosurgery, College of Medicine, University of Florida, 1505 SW Archer Rd, Gainesville, FL 32608, USA
| | - Jairo Hernandez
- Department of Neurosurgery, College of Medicine, University of Florida, 1505 SW Archer Rd, Gainesville, FL 32608, USA
| | - Chadwin Hanna
- Department of Neurosurgery, College of Medicine, University of Florida, 1505 SW Archer Rd, Gainesville, FL 32608, USA
| | - Brandon Lucke-Wold
- Department of Neurosurgery, College of Medicine, University of Florida, 1505 SW Archer Rd, Gainesville, FL 32608, USA
| |
Collapse
|
11
|
Jo S, Sun IC, Ahn CH, Lee S, Kim K. Recent Trend of Ultrasound-Mediated Nanoparticle Delivery for Brain Imaging and Treatment. ACS APPLIED MATERIALS & INTERFACES 2023; 15:120-137. [PMID: 35184560 DOI: 10.1021/acsami.1c22803] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In view of the fact that the blood-brain barrier (BBB) prevents the transport of imaging probes and therapeutic agents to the brain and thus hinders the diagnosis and treatment of brain-related disorders, methods of circumventing this problem (e.g., ultrasound-mediated nanoparticle delivery) have drawn much attention. Among the related techniques, focused ultrasound (FUS) is a favorite means of enhancing drug delivery via transient BBB opening. Photoacoustic brain imaging relies on the conversion of light into heat and the detection of ultrasound signals from contrast agents, offering the benefits of high resolution and large penetration depth. The extensive versatility and adjustable physicochemical properties of nanoparticles make them promising therapeutic agents and imaging probes, allowing for successful brain imaging and treatment through the combined action of ultrasound and nanoparticulate agents. FUS-induced BBB opening enables nanoparticle-based drug delivery systems to efficiently access the brain. Moreover, photoacoustic brain imaging using nanoparticle-based contrast agents effectively visualizes brain morphologies or diseases. Herein, we review the progress in the simultaneous use of nanoparticles and ultrasound in brain research, revealing the potential of ultrasound-mediated nanoparticle delivery for the effective diagnosis and treatment of brain disorders.
Collapse
Affiliation(s)
- SeongHoon Jo
- Center for Theragnosis, Biomedical Research Institute, Korea Institute of Science and Technology, 5, Hwarang-ro, Seongbuk-gu, Seoul 02792, Republic of Korea
- Research Institute of Advanced Materials (RIAM), Department of Materials Science and Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul08826, Republic of Korea
| | - In-Cheol Sun
- Center for Theragnosis, Biomedical Research Institute, Korea Institute of Science and Technology, 5, Hwarang-ro, Seongbuk-gu, Seoul 02792, Republic of Korea
| | - Cheol-Hee Ahn
- Research Institute of Advanced Materials (RIAM), Department of Materials Science and Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul08826, Republic of Korea
| | - Sangmin Lee
- Department of Pharmacy, College of Pharmacy, Kyung Hee University, 26 Kyungheedae-ro, Dongdaemun-gu, Seoul02447, Korea
| | - Kwangmeyung Kim
- Center for Theragnosis, Biomedical Research Institute, Korea Institute of Science and Technology, 5, Hwarang-ro, Seongbuk-gu, Seoul 02792, Republic of Korea
- KU-KIST Graduate School of Converging Science and Technology, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| |
Collapse
|
12
|
Antoniou A, Evripidou N, Panayiotou S, Spanoudes K, Damianou C. Treatment of canine and feline sarcoma using MR-guided focused ultrasound system. J Ultrasound 2022; 25:895-904. [PMID: 35277843 PMCID: PMC9705640 DOI: 10.1007/s40477-022-00672-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 02/27/2022] [Indexed: 11/30/2022] Open
Abstract
PURPOSE In recent years, veterinary medicine has enhanced its applications beyond traditional approaches, progressively incorporating the Focused Ultrasound (FUS) technology. This study investigated the ability of FUS to precisely ablate naturally occurring canine and feline soft tissue sarcomas (STS). METHODS Six dogs and four cats with superficial tumours were enrolled in the study. The tumours were treated with a Magnetic Resonance guided FUS (MRgFUS) robotic system featuring a single element spherically focused transducer of 2.6 MHz. The tumours were then removed by surgery and sent for hematoxylin and eosin (H&E) staining. RESULTS The MRgFUS system was capable of inflicting well-defined overlapping lesions in the tumours. The anatomical sites of the treated tumours were the neck, leg, face, back and belly. Coagulative necrosis was evidenced by histopathology assessment in 80% of cases. CONCLUSION Therefore, this technology can be a therapeutic solution for veterinary cancer and a model for advancing the knowledge on human STS.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Stelios Panayiotou
- SGS Diagnostic Centre of Histopathology and Cytology Limited, 21 Thessalonikis, 3025, Limassol, Cyprus
| | - Kyriakos Spanoudes
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus.
| |
Collapse
|
13
|
Padmakumar S, D'Souza A, Parayath NN, Bleier BS, Amiji MM. Nucleic acid therapies for CNS diseases: Pathophysiology, targets, barriers, and delivery strategies. J Control Release 2022; 352:121-145. [PMID: 36252748 DOI: 10.1016/j.jconrel.2022.10.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 09/10/2022] [Accepted: 10/10/2022] [Indexed: 11/08/2022]
Abstract
Nucleic acid therapeutics have emerged as one of the very advanced and efficacious treatment approaches for debilitating health conditions, including those diseases affecting the central nervous system (CNS). Precise targeting with an optimal control over gene regulation confers long-lasting benefits through the administration of nucleic acid payloads via viral, non-viral, and engineered vectors. The current review majorly focuses on the development and clinical translational potential of non-viral vectors for treating CNS diseases with a focus on their specific design and targeting approaches. These carriers must be able to surmount the various intracellular and extracellular barriers, to ensure successful neuronal transfection and ultimately attain higher therapeutic efficacies. Additionally, the specific challenges associated with CNS administration also include the presence of blood-brain barrier (BBB), the complex pathophysiological and biochemical changes associated with different disease conditions and the existence of non-dividing cells. The advantages offered by lipid-based or polymeric systems, engineered proteins, particle-based systems coupled with various approaches of neuronal targeting have been discussed in the context of a variety of CNS diseases. The possibilities of rapid yet highly efficient gene modifications rendered by the breakthrough methodologies for gene editing and gene manipulation have also opened vast avenues of research in neuroscience and CNS disease therapy. The current review also underscores the extensive scientific efforts to optimize specialized, efficacious yet non-invasive and safer administration approaches to overcome the therapeutic delivery challenges specifically posed by the CNS transport barriers and the overall obstacles to clinical translation.
Collapse
Affiliation(s)
- Smrithi Padmakumar
- Department of Pharmaceutical Sciences, School of Pharmacy, Northeastern University, Boston, MA 02115, USA
| | - Anisha D'Souza
- Department of Pharmaceutical Sciences, School of Pharmacy, Northeastern University, Boston, MA 02115, USA; Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA 20115, USA
| | - Neha N Parayath
- Department of Pharmaceutical Sciences, School of Pharmacy, Northeastern University, Boston, MA 02115, USA
| | - Benjamin S Bleier
- Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA 20115, USA
| | - Mansoor M Amiji
- Department of Pharmaceutical Sciences, School of Pharmacy, Northeastern University, Boston, MA 02115, USA; Department of Chemical Engineering, College of Engineering, Northeastern University, Boston, MA 02115, USA.
| |
Collapse
|
14
|
Antoniou A, Georgiou L, Evripidou N, Ioannides C, Damianou C. Challenges regarding MR compatibility of an MRgFUS robotic system. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 344:107317. [PMID: 36279604 DOI: 10.1016/j.jmr.2022.107317] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 10/11/2022] [Accepted: 10/13/2022] [Indexed: 06/16/2023]
Abstract
Numerous challenges are faced when employing Magnetic Resonance guided Focused Ultrasound (MRgFUS) hardware in the Magnetic Resonance Imaging (MRI) setting. The current study aimed to provide insights on this topic through a series of experiments performed in the framework of evaluating the MRI compatibility of an MRgFUS robotic device. All experiments were performed in a 1.5 T MRI scanner. The main metric for MRI compatibility assessment was the signal to noise ratio (SNR). Measurements were carried out in a tissue mimicking phantom and freshly excised pork tissue under various activation states of the system. In the effort to minimize magnetic interference and image distortion, various set-up parameters were examined. Significant SNR degradation and image distortion occurred when the FUS transducer was activated mainly owing to FUS-induced target and coil vibrations and was getting worse as the output power was increased. Proper design and stable positioning of the imaged phantom play a critical role in reducing these vibrations. Moreover, isolation of the phantom from the imaging coil was proven essential for avoiding FUS-induced vibrations from being transferred to the coil during sonication and resulted in a more than 3-fold increase in SNR. The use of a multi-channel coil increased the SNR by up to 50 % compared to a single-channel coil. Placement of the electronics outside the coil detection area increased the SNR by about 65 %. A similar SNR improvement was observed when the encoders' counting pulses were deactivated. Overall, this study raises awareness about major challenges regarding operation of an MRgFUS system in the MRI environment and proposes simple measures that could mitigate the impact of noise sources so that the monitoring value of MR imaging in FUS applications is not compromised.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| | - Leonidas Georgiou
- German Oncology Center, Department of Interventional Radiology, Limassol, Cyprus.
| | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| | - Cleanthis Ioannides
- German Oncology Center, Department of Interventional Radiology, Limassol, Cyprus.
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| |
Collapse
|
15
|
Yamamoto K, Sarica C, Loh A, Vetkas A, Samuel N, Milano V, Zemmar A, Germann J, Cheyuo C, Boutet A, Elias GJ, Ito H, Taira T, Lozano AM. Magnetic resonance-guided focused ultrasound for the treatment of tremor. Expert Rev Neurother 2022; 22:849-861. [PMID: 36469578 DOI: 10.1080/14737175.2022.2147826] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
INTRODUCTION Magnetic resonance-guided focused ultrasound (MRgFUS) is an emerging treatment for tremor and other movement disorders. An incisionless therapy, it is becoming increasingly common worldwide. However, given MRgFUS' relative novelty, there remain limited data on its benefits and adverse effects. AREAS COVERED We review the current state of evidence of MRgFUS for tremor, highlight its challenges, and discuss future perspectives. EXPERT OPINION Essential tremor (ET) has been the major indication for MRgFUS since a milestone randomized controlled trial (RCT) in 2016, with substantial evidence attesting to the efficacy and acceptable safety profile of this treatment. Patients with other tremor etiologies are also being treated with MRgFUS, with studies - including an RCT - suggesting parkinsonian tremor in particular responds well to this intervention. Additionally, targets other than the ventral intermediate nucleus, such as the subthalamic nucleus and internal segment of the globus pallidus, have been reported to improve parkinsonian symptoms beyond tremor, including rigidity and bradykinesia. Although MRgFUS is encumbered by certain unique technical challenges, it nevertheless offers significant advantages compared to alternative neurosurgical interventions for tremor. The fast-growing interest in this treatment modality will likely lead to further scientific and technological advancements that could optimize and expand its therapeutic potential.
Collapse
Affiliation(s)
- Kazuaki Yamamoto
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada
| | - Can Sarica
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada
| | - Aaron Loh
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada
| | - Artur Vetkas
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada.,Department of Neurosurgery, School of Medicine, University of Tartu, Estonia
| | - Nardin Samuel
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada
| | - Vanessa Milano
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada
| | - Ajmal Zemmar
- Department of Neurosurgery, University of Louisville, School of Medicine, KY, USA.,Department of Neurosurgery, Henan University People's Hospital, Henan University School of Medicine, China
| | - Jürgen Germann
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada
| | - Cletus Cheyuo
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada
| | - Alexandre Boutet
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada.,Joint Department of Medical Imaging, University of Toronto, Ontario, Canada
| | - Gavin Jb Elias
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada
| | - Hisashi Ito
- Department of Neurology, Shonantobu General Hospital, Japan.,Department of Neurology, Shonan Fujisawa Tokushukai Hospital, Japan
| | - Takaomi Taira
- Department of Neurosurgery, Tokyo Women's Medical University, Japan
| | - Andres M Lozano
- Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, University of Toronto, Ontario, Canada.,Krembil Research Institute, Toronto, Ontario, Canada
| |
Collapse
|
16
|
Stocker GE, Lundt JE, Sukovich JR, Miller RM, Duryea AP, Hall TL, Xu Z. A Modular, Kerf-Minimizing Approach for Therapeutic Ultrasound Phased Array Construction. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2766-2775. [PMID: 35617178 PMCID: PMC9594968 DOI: 10.1109/tuffc.2022.3178291] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A novel method for fabricating a modular, kerf-minimizing histotripsy phased array was developed and tested. The method utilizes arbitrarily shaped elements, 3-D printing, water jet cutting, and a thin, 125- [Formula: see text] electrically insulating epoxy coating to maximize aperture utilization while allowing for replacement of individual transducer modules. The method was used to fabricate a 750-kHz truncated circular aperture array (165 mm ×234 mm) transducer with a focal length of 142 mm. The aperture was segmented into 260 arc-shaped modular elements, each approximately 11.5 mm ×11.5 mm, arranged in concentric rings. The resulting aperture utilization was 92%. The full-width-half-maximum (FWHM) focal zone of the array was measured to be 1.6 mm ×1.1 mm ×4.5 mm, and the FWHM electrical steering range was measured to be 38.5 mm ×33 mm 40 mm. The array was estimated to be capable of generating approximately 120-MPa peak negative pressure at the geometric focus. In addition, the array was used to ablate a 5-cm3 volume of tissue with electric focal steering.
Collapse
Affiliation(s)
- Greyson E. Stocker
- Department of Biomedical Engineering at the University of Michigan, Ann Arbor, MI 48109
| | | | - Jonathan R. Sukovich
- Department of Biomedical Engineering at the University of Michigan, Ann Arbor, MI 48109
| | | | | | - Timothy L. Hall
- Department of Biomedical Engineering at the University of Michigan, Ann Arbor, MI 48109
| | - Zhen Xu
- Department of Biomedical Engineering at the University of Michigan, Ann Arbor, MI 48109
| |
Collapse
|
17
|
Szewczyk B, Tarasek M, Campwala Z, Trowbridge R, Zhao Z, Johansen PM, Olmsted Z, Bhushan C, Fiveland E, Ghoshal G, Heffter T, Tavakkolmoghaddam F, Bales C, Wang Y, Rajamani DK, Gandomi K, Nycz C, Jeannotte E, Mane S, Nalwalk J, Burdette EC, Fischer G, Yeo D, Qian J, Pilitsis J. What happens to brain outside the thermal ablation zones? An assessment of needle-based therapeutic ultrasound in survival swine. Int J Hyperthermia 2022; 39:1283-1293. [PMID: 36162814 DOI: 10.1080/02656736.2022.2126901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022] Open
Abstract
BACKGROUND In stereotactic radiosurgery, isodose lines must be considered to determine how surrounding tissue is affected. In thermal ablative therapy, such as laser interstitial thermal therapy (LITT), transcranial MR-guided focused ultrasound (tcMRgFUS), and needle-based therapeutic ultrasound (NBTU), how the surrounding area is affected has not been well studied. OBJECTIVE We aimed to quantify the transition zone surrounding the ablation core created by magnetic resonance-guided robotically-assisted (MRgRA) delivery of NBTU using multi-slice volumetric 2-D magnetic resonance thermal imaging (MRTI) and subsequent characterization of the resultant tissue damage using histopathologic analysis. METHODS Four swine underwent MRgRA NBTU using varying duration and wattage for treatment delivery. Serial MRI images were obtained, and the most representative were overlaid with isodose lines and compared to brain tissue acquired postmortem which underwent histopathologic analysis. These results were also compared to predicted volumes using a finite element analysis model. Contralateral brain tissue was used for control data. RESULTS Intraoperative MRTI thermal isodose contours were characterized and comprehensively mapped to post-operative MRI images and qualitatively compared with histological tissue sections postmortem. NBTU 360° ablations induced smaller lesion volumes (33.19 mm3; 120 s, 3 W; 30.05 mm3, 180 s, 4 W) versus 180° ablations (77.20 mm3, 120 s, 3 W; 109.29 mm3; 180 s; 4 W). MRTI/MRI overlay demonstrated the lesion within the proximal isodose lines. The ablation-zone was characterized by dense macrophage infiltration and glial/neuronal loss as demonstrated by glial fibrillary acidic protein (GFAP) and neurofilament (NF) absence and avid CD163 staining. The transition-zone between lesion and normal brain demonstrated decreased macrophage infiltration and measured ∼345 microns (n - 3). We did not detect overt hemorrhages or signs of edema in the adjacent spared tissue. CONCLUSION We successfully performed MRgRA NBTU ablation in swine and demonstrated minimal histologic changes extended past the ablation-zone. The lesion was characterized by macrophage infiltration and glial/neuronal loss which decreased through the transition-zone.
Collapse
Affiliation(s)
- Benjamin Szewczyk
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA.,Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | | | - Zahabiya Campwala
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | - Rachel Trowbridge
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | - Zhanyue Zhao
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Phillip M Johansen
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| | - Zachary Olmsted
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | | | | | | | | | | | - Charles Bales
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Yang Wang
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Dhruv Kool Rajamani
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Katie Gandomi
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Christopher Nycz
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Erin Jeannotte
- Animal Resources Facility, Albany Medical Center, Albany, NY, USA
| | - Shweta Mane
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | - Julia Nalwalk
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | | | - Gregory Fischer
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA
| | - Desmond Yeo
- GE Global Research Center, Niskayuna, NY, USA
| | - Jiang Qian
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA.,Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA
| | - Julie Pilitsis
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA.,Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany, NY, USA.,Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA
| |
Collapse
|
18
|
Hu Z, Chen S, Yang Y, Gong Y, Chen H. An Affordable and Easy-to-Use Focused Ultrasound Device for Noninvasive and High Precision Drug Delivery to the Mouse Brain. IEEE Trans Biomed Eng 2022; 69:2723-2732. [PMID: 35157574 PMCID: PMC9443669 DOI: 10.1109/tbme.2022.3150781] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Focused ultrasound (FUS) combined with microbubble-mediated blood-brain barrier (BBB) opening (FUS-BBBO) is not only a promising technique for clinical applications but also a powerful tool for preclinical research. However, existing FUS devices for preclinical research are expensive, bulky, and lack the precision needed for small animal research, which limits the broad adoption of this promising technique by the research community. Our objective was to design and fabricate an affordable, easy-to-use, high-precision FUS device for small animal research. METHODS We designed and fabricated in-house mini-FUS transducers (∼$80 each in material cost) with three frequencies (1.5, 3.0, and 6.0 MHz) and integrated them with a stereotactic frame for precise mouse brain targeting using established stereotactic procedures. The BBB opening volume by FUS at different acoustic pressures (0.20-0.57 MPa) was quantified using T1-weighted contrast-enhanced magnetic resonance imaging of gadolinium leakage and fluorescence imaging of Evans blue extravasation. RESULTS The targeting accuracy of the device as measured by the offset between the desired target location and the centroid of BBBO was 0.63 ± 0.19 mm. The spatial precision of the device in targeting individual brain structures was improved by the use of higher frequency FUS transducers. The BBB opening volume had high linear correlations with the cavitation index (defined by the ratio between acoustic pressure and frequency) and mechanical index (defined by the ratio between acoustic pressure and the square root of frequency). The correlation coefficient of the cavitation index was slightly higher than that of the mechanical index. CONCLUSION This study demonstrated that spatially accurate and precise BBB opening was achievable using an affordable and easy-to-use FUS device. The BBB opening volume was tunable by modulating the cavitation index. This device is expected to decrease the barriers to the adoption of the FUS-BBBO technique by the broad research community.
Collapse
|
19
|
Huang Y, Wen P, Song B, Li Y. Numerical investigation of the energy distribution of Low-intensity transcranial focused ultrasound neuromodulation for hippocampus. ULTRASONICS 2022; 124:106724. [PMID: 35299039 DOI: 10.1016/j.ultras.2022.106724] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 03/02/2022] [Accepted: 03/04/2022] [Indexed: 06/14/2023]
Abstract
OBJECTIVE Ultrasonic neuromodulation as a safe and non-invasive brain stimulation method that delivers a low-intensity, focused ultrasound to nervous system tissue in a targeted area of the brain. The objective of this study is to numerically investigate the ultrasound wave propagation and the energy distribution within the brain tissues using customized single element focused ultrasound transducers (SEFT), targeting the hippocampus. METHODS A high resolution detailed human head model with seven tissue types was constructed from magnetic resonance imaging (MRI). A full-wave finite-difference time-domain simulation platform, Sim4life, was then used to simulate a 3D non-linear ultrasound wave equation to the specific region of interest, the hippocampus. Three customized SEFT were used to test the effect of transducer positions, and another customized transducer was used to compare the sensitivity effect on heterogeneous and homogeneous brain models. Finally, the sensitivity and performance of low intensity focusing ultrasound stimulation were evaluated. RESULTS An optimized application of SEFT was customized to deliver 100 W/m2 intensity of energy deposition at the hippocampus region. About 85.65% of the generated volume beam was delivered to the targeted hippocampus region and the beam overlap parameter was affected by different transducer positions. Deflection angle changes of SEFT at the range of ± 5% did not have a significant effect on energy delivery and position displacement. Only 0.5% of peak pressure change was observed between heterogeneous and homogeneous brain models. The sensitivity analysis also showed that the sound speed is the most influential acoustic parameter. SIGNIFICANCE This study demonstrated that ultrasound neuromodulation targeting the depth brain tissue of the hippocampus could be a potential and promising alternative method to some non-acoustic brain stimulation modalities. In the numerical study of ultrasound brain stimulations, ultrasound parameters and the brain model need to be properly determined to simulate the ultrasonic neuromodulations.
Collapse
Affiliation(s)
- Yi Huang
- School of Engineering, University of Southern Queensland, Toowoomba 4350, Australia.
| | - Peng Wen
- School of Engineering, University of Southern Queensland, Toowoomba 4350, Australia
| | - Bo Song
- School of Engineering, University of Southern Queensland, Toowoomba 4350, Australia
| | - Yan Li
- School of Mathematics, Physics and Computing, University of Southern Queensland, Toowoomba 4350, Australia
| |
Collapse
|
20
|
Zhang H, Xu M, Liu M, Song X, He F, Chen S, Ming D. Biological current source imaging method based on acoustoelectric effect: A systematic review. Front Neurosci 2022; 16:807376. [PMID: 35924223 PMCID: PMC9339687 DOI: 10.3389/fnins.2022.807376] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 06/28/2022] [Indexed: 11/13/2022] Open
Abstract
Neuroimaging can help reveal the spatial and temporal diversity of neural activity, which is of utmost importance for understanding the brain. However, conventional non-invasive neuroimaging methods do not have the advantage of high temporal and spatial resolution, which greatly hinders clinical and basic research. The acoustoelectric (AE) effect is a fundamental physical phenomenon based on the change of dielectric conductivity that has recently received much attention in the field of biomedical imaging. Based on the AE effect, a new imaging method for the biological current source has been proposed, combining the advantages of high temporal resolution of electrical measurements and high spatial resolution of focused ultrasound. This paper first describes the mechanism of the AE effect and the principle of the current source imaging method based on the AE effect. The second part summarizes the research progress of this current source imaging method in brain neurons, guided brain therapy, and heart. Finally, we discuss the problems and future directions of this biological current source imaging method. This review explores the relevant research literature and provides an informative reference for this potential non-invasive neuroimaging method.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
| | - Minpeng Xu
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin International Joint Research Centre for Neural Engineering, Tianjin University, Tianjin, China
| | - Miao Liu
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin International Joint Research Centre for Neural Engineering, Tianjin University, Tianjin, China
| | - Xizi Song
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin International Joint Research Centre for Neural Engineering, Tianjin University, Tianjin, China
| | - Feng He
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin International Joint Research Centre for Neural Engineering, Tianjin University, Tianjin, China
| | - Shanguang Chen
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin International Joint Research Centre for Neural Engineering, Tianjin University, Tianjin, China
- National Key Laboratory of Human Factors Engineering, China Astronaut Research and Training Center, Beijing, China
| | - Dong Ming
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
- Tianjin Key Laboratory of Brain Science and Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin International Joint Research Centre for Neural Engineering, Tianjin University, Tianjin, China
- *Correspondence: Dong Ming
| |
Collapse
|
21
|
Thies M, Oelze ML. Combined Therapy Planning, Real-Time Monitoring, and Low Intensity Focused Ultrasound Treatment Using a Diagnostic Imaging Array. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:1410-1419. [PMID: 34986094 PMCID: PMC9199060 DOI: 10.1109/tmi.2021.3140176] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Low intensity focused ultrasound (FUS) therapies use low intensity focused ultrasound waves, typically in combination with microbubbles, to non-invasively induce a variety of therapeutic effects. FUS therapies require pre-therapy planning and real-time monitoring during treatment to ensure the FUS beam is correctly targeted to the desired tissue region. To facilitate more streamlined FUS treatments, we present a system for pre-therapy planning, real-time FUS beam visualization, and low intensity FUS treatment using a single diagnostic imaging array. Therapy planning was accomplished by manually segmenting a B-mode image captured by the imaging array and calculating a sonication pattern for the treatment based on the user-input region of interest. For real-time monitoring, the imaging array transmitted a visualization pulse which was focused to the same location as the FUS therapy beam and ultrasonic backscatter from this pulse was used to reconstruct the intensity field of the FUS beam. The therapy planning and beam monitoring techniques were demonstrated in a tissue-mimicking phantom and in a rat tumor in vivo while a mock FUS treatment was carried out. The FUS pulse from the imaging array was excited with an MI of 0.78, which suggests that the array could be used to administer select low intensity FUS treatments involving microbubble activation.
Collapse
|
22
|
Kang KC, Kim YH, Kim JN, Kabir M, Zhang Y, Ghanouni P, Park KK, Firouzi K, Khuri-Yakub BT. Increasing the transmission efficiency of transcranial ultrasound using a dual-mode conversion technique based on Lamb waves. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:2159. [PMID: 35364946 PMCID: PMC8957390 DOI: 10.1121/10.0009849] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 02/24/2022] [Accepted: 03/05/2022] [Indexed: 06/14/2023]
Abstract
Transcranial focused ultrasound (FUS) is a noninvasive treatment for brain tumors and neuromodulation. Based on normal incidence, conventional FUS techniques use a focused or an array of ultrasonic transducers to overcome the attenuation and absorption of ultrasound in the skull; however, this remains the main limitation of using FUS. A dual-mode conversion technique based on Lamb waves is proposed to achieve high transmission efficiency. This concept was validated using the finite element analysis (FEA) and experiments based on changes in the incident angle. Aluminum, plexiglass, and a human skull were used as materials with different attenuations. The transmission loss was calculated for each material, and the results were compared with the reflectance function of the Lamb waves. Oblique incidence based on dual-mode conversion exhibited a better transmission efficiency than that of a normal incidence for all of the specimens. The total transmission losses for the materials were 13.7, 15.46, and 3.91 dB less than those associated with the normal incidence. A wedge transducer was designed and fabricated to implement the proposed method. The results demonstrated the potential applicability of the dual-mode conversion technique for the human skull.
Collapse
Affiliation(s)
- Ki Chang Kang
- Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Young Hun Kim
- Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Jeong Nyeon Kim
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - Minoo Kabir
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - Yichi Zhang
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, California 94305, USA
| | - Kwan Kyu Park
- Mechanical Convergence Engineering, Hanyang University, Seoul, Republic of Korea
| | - Kamyar Firouzi
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| | - Burtus T Khuri-Yakub
- E. L. Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA
| |
Collapse
|
23
|
Zhang Q, Mao J, Zhang Y, Lu M, Li R, Liu X, Liu Y, Yang R, Wang X, Geng Y, Qi T, Wan M. Multiple-Focus Patterns of Sparse Random Array Using Particle Swarm Optimization for Ultrasound Surgery. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:565-579. [PMID: 34757903 DOI: 10.1109/tuffc.2021.3127222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
This study aims to investigate the feasibility and potential of sparse random arrays driven by the particle swarm optimization (PSO) algorithm to generate multiple-focus patterns and a large scanning range without grating lobes, which extends the scanning range of focused ultrasound in the treatment of brain tumors, opening the blood-brain barrier, and neuromodulation. Operating at 1.1 MHz, a random spherical array with 200 square elements (sparseness 58%) and a sparse random array with 660 square elements (sparseness 41%) driven by PSO are employed to simulate different focus patterns. With the same radius of curvature and diameter of transducer and element size, the scanning range of the off-axis single focus of a random 200-element array is two times that of an ordinary array using symmetric arrangement. The focal volume of multiple-focus patterns of the random array is 18 times that of the single focus. The single focus of the sparse random array with 660 elements could steer up to ±23 mm in the radial direction, without grating lobes. The maximum distance between two foci in a multiple-focus "S"-shaped deflection is approximately 25 mm. Simulation results illustrate the capability of a focused beam steered in 3-D space. Multiple-focus patterns could significantly increase the focal volume and shorten the treatment time for large target volumes. Simulation results show the feasibility and potential of the method combining PSO with a sparse random array to generate flexible focus patterns that can adapt to different needs in different tissue treatments.
Collapse
|
24
|
Binder DK, Shah BB, Elias WJ. Focused ultrasound and other lesioning in the treatment of tremor. J Neurol Sci 2022; 435:120193. [DOI: 10.1016/j.jns.2022.120193] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 01/24/2022] [Accepted: 02/17/2022] [Indexed: 11/24/2022]
|
25
|
Tarnaud T, Joseph W, Schoeters R, Martens L, Tanghe E. Improved alpha-beta power reduction via combined electrical and ultrasonic stimulation in a parkinsonian cortex-basal ganglia-thalamus computational model. J Neural Eng 2021; 18. [PMID: 34874304 DOI: 10.1088/1741-2552/ac3f6d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 12/02/2021] [Indexed: 11/11/2022]
Abstract
Objective. To investigate computationally the interaction of combined electrical and ultrasonic modulation of isolated neurons and of the parkinsonian cortex-basal ganglia-thalamus loop.Approach. Continuous-wave or pulsed electrical and ultrasonic neuromodulation is applied to isolated Otsuka plateau-potential generating subthalamic nucleus (STN) and Pospischil regular, fast and low-threshold spiking cortical cells in a temporally alternating or simultaneous manner. Similar combinations of electrical/ultrasonic waveforms are applied to a parkinsonian biophysical cortex-basal ganglia-thalamus neuronal network. Ultrasound-neuron interaction is modelled respectively for isolated neurons and the neuronal network with the NICE and SONIC implementations of the bilayer sonophore underlying mechanism. Reduction inα-βspectral energy is used as a proxy to express improvement in Parkinson's disease by insonication and electrostimulation.Main results. Simultaneous electro-acoustic stimulation achieves a given level of neuronal activity at lower intensities compared to the separate stimulation modalities. Conversely, temporally alternating stimulation with50 Hzelectrical and ultrasound pulses is capable of eliciting100 HzSTN firing rates. Furthermore, combination of ultrasound with hyperpolarizing currents can alter cortical cell relative spiking regimes. In the parkinsonian neuronal network, continuous-wave and pulsed ultrasound reduce pathological oscillations by different mechanisms. High-frequency pulsed separated electrical and ultrasonic deep brain stimulation (DBS) reduce pathologicalα-βpower by entraining STN-neurons. In contrast, continuous-wave ultrasound reduces pathological oscillations by silencing the STN. Compared to the separated stimulation modalities, temporally simultaneous or alternating electro-acoustic stimulation can achieve higher reductions inα-βpower for the same safety contraints on electrical/ultrasonic intensity.Significance. Focused ultrasound has the potential of becoming a non-invasive alternative of conventional DBS for the treatment of Parkinson's disease. Here, we elaborate on proposed benefits of combined electro-acoustic stimulation in terms of improved dynamic range, efficiency, spatial resolution, and neuronal selectivity.
Collapse
Affiliation(s)
- Thomas Tarnaud
- Department of Information Technology (INTEC-WAVES/IMEC), Ghent University/IMEC, Technologiepark 126Zwijnaarde, 9052, Belgium
| | - Wout Joseph
- Department of Information Technology (INTEC-WAVES/IMEC), Ghent University/IMEC, Technologiepark 126Zwijnaarde, 9052, Belgium
| | - Ruben Schoeters
- Department of Information Technology (INTEC-WAVES/IMEC), Ghent University/IMEC, Technologiepark 126Zwijnaarde, 9052, Belgium
| | - Luc Martens
- Department of Information Technology (INTEC-WAVES/IMEC), Ghent University/IMEC, Technologiepark 126Zwijnaarde, 9052, Belgium
| | - Emmeric Tanghe
- Department of Information Technology (INTEC-WAVES/IMEC), Ghent University/IMEC, Technologiepark 126Zwijnaarde, 9052, Belgium
| |
Collapse
|
26
|
Segar DJ, Lak AM, Lee S, Harary M, Chavakula V, Lauro P, McDannold N, White J, Cosgrove GR. Lesion location and lesion creation affect outcomes after focused ultrasound thalamotomy. Brain 2021; 144:3089-3100. [PMID: 34750621 DOI: 10.1093/brain/awab176] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/13/2021] [Accepted: 04/05/2021] [Indexed: 11/13/2022] Open
Abstract
MRI-guided focused ultrasound thalamotomy has been shown to be an effective treatment for medication refractory essential tremor. Here, we report a clinical-radiological analysis of 123 cases of MRI-guided focused ultrasound thalamotomy, and explore the relationships between treatment parameters, lesion characteristics and outcomes. All patients undergoing focused ultrasound thalamotomy by a single surgeon were included. The procedure was performed as previously described, and patients were followed for up to 1 year. MRI was performed 24 h post-treatment, and lesion locations and volumes were calculated. We retrospectively evaluated 118 essential tremor patients and five tremor-dominant Parkinson's disease patients who underwent thalamotomy. At 24 h post-procedure, tremor abated completely in the treated hand in 81 essential tremor patients. Imbalance, sensory disturbances and dysarthria were the most frequent acute adverse events. Patients with any adverse event had significantly larger lesions, while inferolateral lesion margins were associated with a higher incidence of motor-related adverse events. Twenty-three lesions were identified with irregular tails, often extending into the internal capsule; 22 of these patients experienced at least one adverse event. Treatment parameters and lesion characteristics changed with increasing surgeon experience. In later cases, treatments used higher maximum power (normalized to skull density ratio), accelerated more quickly to high power, and delivered energy over fewer sonications. Larger lesions were correlated with a rapid rise in both power delivery and temperature, while increased oedema was associated with rapid rise in temperature and the maximum power delivered. Total energy and total power did not significantly affect lesion size. A support vector regression was trained to predict lesion size and confirmed the most valuable predictors of increased lesion size as higher maximum power, rapid rise to high-power delivery, and rapid rise to high tissue temperatures. These findings may relate to a decrease in the energy efficiency of the treatment, potentially due to changes in acoustic properties of skull and tissue at higher powers and temperatures. We report the largest single surgeon series of focused ultrasound thalamotomy to date, demonstrating tremor relief and adverse events consistent with reported literature. Lesion location and volume impacted adverse events, and an irregular lesion tail was strongly associated with adverse events. High-power delivery early in the treatment course, rapid temperature rise, and maximum power were dominant predictors of lesion volume, while total power, total energy, maximum energy and maximum temperature did not improve prediction of lesion volume. These findings have critical implications for treatment planning in future patients.
Collapse
Affiliation(s)
- David J Segar
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Asad M Lak
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Shane Lee
- Department of Neuroscience, Brown University, Providence, RI, USA
| | - Maya Harary
- Department of Neurosurgery, University of California, Los Angeles, CA, USA
| | - Vamsidhar Chavakula
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Peter Lauro
- Department of Neuroscience, Brown University, Providence, RI, USA
| | - Nathan McDannold
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Jason White
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - G Rees Cosgrove
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
27
|
Kim HC, Lee W, Kunes J, Yoon K, Lee JE, Foley L, Kowsari K, Yoo SS. Transcranial focused ultrasound modulates cortical and thalamic motor activity in awake sheep. Sci Rep 2021; 11:19274. [PMID: 34588588 PMCID: PMC8481295 DOI: 10.1038/s41598-021-98920-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 09/08/2021] [Indexed: 11/09/2022] Open
Abstract
Transcranial application of pulsed low-intensity focused ultrasound (FUS) modulates the excitability of region-specific brain areas, and anesthetic confounders on brain activity warrant the evaluation of the technique in awake animals. We examined the neuromodulatory effects of FUS in unanesthetized sheep by developing a custom-fit headgear capable of reproducibly placing an acoustic focus on the unilateral motor cortex (M1) and corresponding thalamic area. The efferent responses to sonication, based on the acoustic parameters previously identified in anesthetized sheep, were measured using electromyography (EMG) from both hind limbs across three experimental conditions: on-target sonication, off-target sonication, and without sonication. Excitatory sonication yielded greater amplitude of EMG signals obtained from the hind limb contralateral to sonication than that from the ipsilateral limb. Spurious appearance of motion-related EMG signals limited the amount of analyzed data (~ 10% selection of acquired data) during excitatory sonication, and the averaged EMG response rates elicited by the M1 and thalamic stimulations were 7.5 ± 1.4% and 6.7 ± 1.5%, respectively. Suppressive sonication, while sheep walked on the treadmill, temporarily reduced the EMG amplitude from the limb contralateral to sonication. No significant change was found in the EMG amplitudes during the off-target sonication. Behavioral observation throughout the study and histological analysis showed no sign of brain tissue damage caused by the acoustic stimulation. Marginal response rates observed during excitatory sonication call for technical refinement to reduce motion artifacts during EMG acquisitions as well as acoustic aberration correction schemes to improve spatial accuracy of sonication. Yet, our results indicate that low-intensity FUS modulated the excitability of regional brain tissues reversibly and safely in awake sheep, supporting its potential in theragnostic applications.
Collapse
Affiliation(s)
- Hyun-Chul Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Jennifer Kunes
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Kyungho Yoon
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Ji Eun Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Lori Foley
- Translational Discovery Laboratory, Brigham and Women's Hospital, Boston, MA, USA
| | - Kavin Kowsari
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA.
| |
Collapse
|
28
|
Payne A, Chopra R, Ellens N, Chen L, Ghanouni P, Sammet S, Diederich C, Ter Haar G, Parker D, Moonen C, Stafford J, Moros E, Schlesinger D, Benedict S, Wear K, Partanen A, Farahani K. AAPM Task Group 241: A medical physicist's guide to MRI-guided focused ultrasound body systems. Med Phys 2021; 48:e772-e806. [PMID: 34224149 DOI: 10.1002/mp.15076] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 04/28/2021] [Accepted: 06/21/2021] [Indexed: 11/07/2022] Open
Abstract
Magnetic resonance-guided focused ultrasound (MRgFUS) is a completely non-invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications.
Collapse
Affiliation(s)
- Allison Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Rajiv Chopra
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| | | | - Lili Chen
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Steffen Sammet
- Department of Radiology, University of Chicago, Chicago, IL, USA
| | - Chris Diederich
- Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| | | | - Dennis Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Chrit Moonen
- Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Jason Stafford
- Department of Imaging Physics, MD Anderson Cancer Center, Houston, TX, USA
| | - Eduardo Moros
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL, USA
| | - David Schlesinger
- Department of Radiation Oncology, University of Virginia, Charlottesville, VA, USA
| | | | - Keith Wear
- U.S. Food and Drug Administration, Silver Spring, MD, USA
| | | | - Keyvan Farahani
- National Cancer Institute, National Institutes of Health, Rockville, MD, USA
| |
Collapse
|
29
|
Stavarache MA, Chazen JL, Kaplitt MG. Foundations of Magnetic Resonance-Guided Focused Ultrasonography. World Neurosurg 2021; 145:567-573. [PMID: 33348522 DOI: 10.1016/j.wneu.2020.08.051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/01/2020] [Indexed: 11/26/2022]
Abstract
The ability of ultrasonography to safely penetrate deeply into the brain has made it an attractive technology for neurological applications for almost 1 century. Having recognized that converging ultrasound waves could deliver high levels of energy to a target and spare the overlying and surrounding brain, early applications used craniotomies to allow transducers to contact the brain or dural surface. The development of transducer arrays that could permit the transit of sufficient numbers of ultrasound waves to deliver high energies to a target, even with the loss of energy from the skull, has now resulted in clinical systems that can permit noninvasive focused ultrasound procedures that leave the skull intact. Another major milestone in the field was the marriage of focused ultrasonography with magnetic resonance thermometry. This provides real-time feedback regarding the level and location of brain tissue heating, allowing for precise elevation of temperatures within a desired target to lead to focal therapeutic lesions. The major clinical use of this technology, at present, has been limited to treatment of refractory essential tremor and parkinsonian tremor, although the first study of this approach had targeted sensory thalamus for refractory pain, and new targets and disease indications are under study. Finally, focused ultrasonography can also be used at a lower frequency and energy level when combined with intravenous microbubbles to create cavitations, which will open the blood-brain barrier rather than ablate tissue. In the present review, we have discussed the historical and scientific foundations and current clinical applications of magnetic resonance-guided focused ultrasonography and the genesis and background that led to the use of this technique for focal blood-brain barrier disruption.
Collapse
Affiliation(s)
- Mihaela A Stavarache
- Department of Neurological Surgery, Weill Cornell Medical College, New York, New York, USA
| | - J Levi Chazen
- Department of Radiology, Weill Cornell Medical College, New York, New York, USA
| | - Michael G Kaplitt
- Department of Neurological Surgery, Weill Cornell Medical College, New York, New York, USA.
| |
Collapse
|
30
|
Mazzotti M, Kohtanen E, Erturk A, Ruzzene M. Radiation Characteristics of Cranial Leaky Lamb Waves. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2129-2140. [PMID: 33544671 DOI: 10.1109/tuffc.2021.3057309] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
We numerically and experimentally investigate the dispersion properties of leaky Lamb waves in the cranial bone. Cranial Lamb waves leak energy from the skull into the brain when propagating at speeds higher than the speed of sound in the surrounding fluid. The understanding of their radiation mechanism is significantly complicated by the geometric and mechanical characteristics of the cortical tables and the trabecular bone (diploë). Toward such understanding, we here analyze the sub-1.0 MHz radiation angle dispersion spectrum of porous bone phantoms and parietal bone geometries obtained from μ CT scans. Our numerical results show that, when diploic pores are physically modeled, leakage angles computed from time transient finite-element analyses correspond to those predicted by an equivalent three-layered fluid-loaded waveguide model. For the bone geometries analyzed, two main leaky branches are observed in the near-field dispersion spectrum: a fast wave radiated at small angles, which is related to the fastest fundamental Lamb mode supported by the cranial bone, and a slower wave radiated at larger angles. This observation is also confirmed by experimental tests carried out on an immersed parietal bone.
Collapse
|
31
|
Tsai KWK, Chen JC, Lai HC, Chang WC, Taira T, Chang JW, Wei CY. The Distribution of Skull Score and Skull Density Ratio in Tremor Patients for MR-Guided Focused Ultrasound Thalamotomy. Front Neurosci 2021; 15:612940. [PMID: 34079434 PMCID: PMC8165389 DOI: 10.3389/fnins.2021.612940] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Accepted: 04/08/2021] [Indexed: 12/20/2022] Open
Abstract
Objective Magnetic resonance-guided focused ultrasound (MRgFUS) is a minimum-invasive surgical approach to non-incisionally cause the thermos-coagulation inside the human brain. The skull score (SS) has already been approved as one of the most dominant factors related to a successful MRgFUS treatment. In this study, we first reveal the SS distribution of the tremor patients, and correlate the SS with the image feature from customized skull density ratio (cSDR). This correlation might give a direction to future clinical studies for improving the SS. Methods Two hundred and forty-six patients received a computed tomography (CT) scan of the brain, and a bone-enhanced filter was applied and reconstructed to a high spatial resolution CT images. The SS of all patients would be estimated by the MRgFUS system after importing the reconstructed CT images into the MRgFUS system. The histogram and the cumulative distribution of the SS from all the patients were calculated to show the percentage of the patients whose SS lower than 0.3 and 0.4. The same CT images of all patients were utilized to calculated the cSDR by first segmented the trabecular bone and the cortical bone from the CT images and divided the average trabecular bone intensity (aTBI) by the average cortical bone intensity (aCBI). The Pearson’s correlations between the SS and the cSDR, aTBI, and the aCBI were calculated, respectively. Results There were 19.19 and 50% of the patient who had the SS lower than the empirical threshold 0.3 and 0.4, respectively. The Pearson’s correlation between the SS and the cSDR, aCBI, and the aTBI were R = 0.8145, 0.5723, and 0.8842. Conclusion Half of the patients were eligible for the MRgFUS thalamotomy based on the SS, and nearly 20% of patients were empirically difficult to achieve a therapeutic temperature during MRgFUS. The SS and our cSDR are highly correlated, and the SS had a higher correlation with aTBI than with aCBI. This is the first report to explicitly reveal the SS population and indicate a potential way to increase the chance to achieve a therapeutic temperature for those who originally have low SS.
Collapse
Affiliation(s)
- Kevin Wen-Kai Tsai
- MR-guided Focused Ultrasound Center, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan
| | - Jui-Cheng Chen
- Neuroscience Laboratory, Department of Neurology, China Medical University Hospital, Taichung City, Taiwan.,School of Medicine, College of Medicine, China Medical University, Taichung City, Taiwan.,Department of Neurology, China Medical University Hsinchu Hospital, Hsinchu, Taiwan
| | - Hui-Chin Lai
- MR-guided Focused Ultrasound Center, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan
| | - Wei-Chieh Chang
- MR-guided Focused Ultrasound Center, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan.,Department of Neurosurgery, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan
| | - Takaomi Taira
- Department of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan
| | - Jin Woo Chang
- Department of Neurosurgery, Yonsei University College of Medicine, Seoul, South Korea
| | - Cheng-Yu Wei
- Department of Exercise and Health Promotion, College of Kinesiology and Health, Chinese Culture University, Taipei, Taiwan.,Department of Neurology, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan
| |
Collapse
|
32
|
Mazzotti M, Sugino C, Kohtanen E, Erturk A, Ruzzene M. Experimental identification of high order Lamb waves and estimation of the mechanical properties of a dry human skull. ULTRASONICS 2021; 113:106343. [PMID: 33540235 DOI: 10.1016/j.ultras.2020.106343] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 11/09/2020] [Accepted: 12/23/2020] [Indexed: 06/12/2023]
Abstract
We experimentally investigate and characterize high order Lamb wave modes in a dry human skull. Specifically, we show that the diploë supports distinct wave modes in the sub-1.0 MHz frequency regime, and we employ these modes for the estimation of equivalent mechanical properties of cortical and trabecular bones. These modes are efficiently generated in a parietal region by direct contact excitation with a wedge beam transducer, and are recorded via infrared laser vibrometry. Frequency/wavenumber data are estimated using a matrix pencil method applied to wavefield measurements recorded on the outer cortical surface. The semi-analytical finite element model of an equivalent three-layered plate provides the platform for the identification of wave modes based on their through-the-thickness profiles, and supports the estimation of equivalent mechanical properties in conjunction with an optimization algorithm developed for this purpose. The results presented herein illustrate how high order Lamb waves can be used to gain understanding of the wave properties of a human skull and to estimate the orthotropic and equivalent isotropic mechanical properties of cortical and trabecular bones.
Collapse
Affiliation(s)
- Matteo Mazzotti
- P.M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA.
| | - Christopher Sugino
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
| | - Eetu Kohtanen
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
| | - Alper Erturk
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
| | - Massimo Ruzzene
- P.M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA
| |
Collapse
|
33
|
Antoniou A, Evripidou N, Giannakou M, Constantinides G, Damianou C. Acoustical properties of 3D printed thermoplastics. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:2854. [PMID: 33940906 DOI: 10.1121/10.0004772] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 04/03/2021] [Indexed: 06/12/2023]
Abstract
With focused ultrasound (FUS) gaining popularity as a therapeutic modality for brain diseases, the need for skull phantoms that are suitable for evaluating FUS protocols is increasing. In the current study, the acoustical properties of several three-dimensional (3D) printed thermoplastic samples were evaluated to assess their suitability to mimic human skull and bone accurately. Samples were 3D printed using eight commercially available thermoplastic materials. The acoustic properties of the printed samples, including attenuation coefficient, speed of sound, and acoustic impedance, were investigated using transmission-through and pulse-echo techniques. The ultrasonic attenuation, estimated at a frequency of 1.1 MHz, varied from approximately 7 to 32 dB/cm. The frequency dependence of attenuation was described by a power law in the frequency range of 0.2-3.5 MHz, and the exponential index of frequency was found to vary from 1.30 to 2.24. The longitudinal velocity of 2.7 MHz sound waves was in the range of 1700-3050 m/s. The results demonstrate that thermoplastics could potentially be used for the 3D construction of high-quality skull phantoms.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 30 Archiepiskopou Kyprianou Street, Limassol, 3036, Cyprus
| | - Nikolas Evripidou
- Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 30 Archiepiskopou Kyprianou Street, Limassol, 3036, Cyprus
| | - Marinos Giannakou
- MEDSONIC LTD, 35 Christaki Kranou Street, Germasogia, Limassol, 4041, Cyprus
| | - Georgios Constantinides
- Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, 30 Archiepiskopou Kyprianou Street, Limassol, 3036, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 30 Archiepiskopou Kyprianou Street, Limassol, 3036, Cyprus
| |
Collapse
|
34
|
Lee W, Weisholtz DS, Strangman GE, Yoo SS. Safety Review and Perspectives of Transcranial Focused Ultrasound Brain Stimulation. BRAIN & NEUROREHABILITATION 2021; 14:e4. [PMID: 36742103 PMCID: PMC9879416 DOI: 10.12786/bn.2021.14.e4] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Revised: 02/17/2021] [Accepted: 03/04/2021] [Indexed: 11/08/2022] Open
Abstract
Ultrasound is an important theragnostic modality in modern medicine. Technical advancement of both acoustic focusing and transcranial delivery have enabled administration of ultrasound waves to localized brain areas with few millimeters of spatial specificity and penetration depth sufficient to reach the thalamus. Transcranial focused ultrasound (tFUS) given at a low acoustic intensity has been shown to increase or suppress the excitability of region-specific brain areas. The neuromodulatory effects can outlast the sonication, suggesting the possibility of inducing neural plasticity needed for neurorehabilitation. Increasing numbers of studies have shown the efficacy and excellent safety profile of the technique, yet comparisons among the safety-related parameters have not been compiled. This review aims to provide safety information and perspectives of tFUS brain stimulation. First, the acoustic parameters most relevant to thermal/mechanical tissue damage are discussed along with regulated parameters for existing ultrasound therapies/diagnostic imaging. Subsequently, the parameters used in studies of large animals, non-human primates, and humans are surveyed and summarized in terms of the acoustic intensity and the mechanical index. The pulse-mode operation and the use of low ultrasound frequency for tFUS-mediated brain stimulation warrant the establishment of new safety guidelines/recommendations for the use of the technique among healthy volunteers, with additional cautionary requirements for its clinical translation.
Collapse
Affiliation(s)
- Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Daniel S. Weisholtz
- Department of Neurology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Gary E. Strangman
- Neural Systems Group, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA, USA
- Center for Space Medicine, Baylor College of Medicine, Houston, TX, USA
- Translational Research Institute, Houston, TX, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
35
|
Sugino C, Ruzzene M, Erturk A. Experimental and Computational Investigation of Guided Waves in a Human Skull. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:787-798. [PMID: 33358510 DOI: 10.1016/j.ultrasmedbio.2020.11.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 11/14/2020] [Accepted: 11/17/2020] [Indexed: 06/12/2023]
Abstract
We investigate guided (Lamb) waves in a human cadaver skull through experiments and computational simulations. Ultrasonic wedge transducers and scanning laser Doppler vibrometry are used respectively to excite and measure Lamb waves propagating in the cranial bone of a degassed skull. Measurements are performed over a section of the parietal bone and temporal bone spanning the squamous suture. The experimental data are analyzed for the identification of wave modes and the characterization of dispersion properties. In the parietal bone, for instance, the A0 wave mode is excited between 200 and 600 kHz, and higher-order Lamb waves are excited from 1 to 1.8 MHz. From the experimental dispersion curves and average thickness extracted from the skull computed tomography scan, we estimate average isotropic material properties that capture the essential dispersion characteristics using a semi-analytical finite-element model. We also explore the leaky and non-leaky wave behavior of the degassed skull with water loading in the cranial cavity. Successful excitation of leaky Lamb waves is confirmed (for higher-order wave modes with phase velocity faster than the speed of sound in water) from 500 kHz to 1.5 MHz, which may find applications in imaging and therapeutics at the brain periphery or skull-brain interface (e.g., for metastases). The non-leaky A0 Lamb wave mode propagates between 200 and 600 kHz, with or without fluid loading, for potential use in skull-related diagnostics and imaging (e.g., for sutures).
Collapse
Affiliation(s)
- Christopher Sugino
- G. W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.
| | - Massimo Ruzzene
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| | - Alper Erturk
- G. W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| |
Collapse
|
36
|
Zubair M, Dickinson RJ. 3D synthetic aperture imaging with a therapeutic spherical random phased array for transcostal applications. Phys Med Biol 2021; 66:035024. [PMID: 33276351 DOI: 10.1088/1361-6560/abd0d0] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Experimental validation of a synthetic aperture imaging technique using a therapeutic random phased array is described, demonstrating the dual nature of imaging and therapy of such an array. The transducer is capable of generating both continuous wave high intensity beams for ablating the tumor and low intensity ultrasound pulses to image the target area. Pulse-echo data is collected from the elements of the phased array to obtain B-mode images of the targets. Since therapeutic arrays are optimized for therapy only with concave apertures having low f-number and large directive elements often coarsely sampled, imaging can not be performed using conventional beamforming. We show that synthetic aperture imaging is capable of processing the acquired RF data to obtain images of the field of interest. Simulations were performed to compare different synthetic aperture imaging techniques to identify the best algorithm in terms of spatial resolution. Experimental validation was performed using a 1 MHz, 256-elements, spherical random phased array with 130 mm radius of curvature. The array was integrated with a research ultrasound scanner via custom connectors to acquire raw RF data for variety of targets. Imaging was implemented using synthetic aperture beamforming to produce images of a rib phantom and ex vivo ribs. The array was shown to resolve spherical targets within ±15 mm of either side of the axis in the focal plane and obtain 3D images of the rib phantom up to ±40 mm of either side of the central axis and at a depth of 3-9 cm from the array surface. The lateral and axial full width half maximum was 1.15 mm and 2.75 mm, respectively. This study was undertaken to emphasize that both therapy and image guidance with a therapeutic random phased array is possible and such a system has the potential to address some major limitations in the existing high intensity focused ultrasound (HIFU) systems. The 3D images obtained with a therapeutic array can be used to identify and locate strong scattering objects aiding to image guidance and treatment planning of the HIFU procedure.
Collapse
Affiliation(s)
- Muhammad Zubair
- Department of Bioengineering, Imperial College London, United Kingdom
| | | |
Collapse
|
37
|
Qu X, Shen G, Wu N, Wu H, Qiao S, Wang E, Chen Y, Wang H. Suppressing Grating Lobes for Transcranial Focused Ultrasound System by Frequency-Modulated Excitation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:341-351. [PMID: 33382650 DOI: 10.1109/tuffc.2020.3047664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Transcranial focused ultrasound is a novel noninvasive therapeutic modality for glioblastoma and other disorders of the brain. However, because the phase aberrations caused by the skull need to be corrected with computed tomography (CT) images, the transcranial transducer is tightly fixed on the patient's head to avoid any variation in the relative position, and the focus shifting relies mainly on the capacity for electronic beam steering. Due to the presence of grating lobes and the rapid degradation of the focus quality with increasing focus-shifting distance, transcranial focus-shifting sonication may damage healthy brain tissue unintentionally. To reduce the risks associated with transcranial focused ultrasound therapy, linear frequency-modulated (FM) excitation is proposed. The k-space corrected pseudospectral time domain (PSTD) and acoustic holography approach based on the Rayleigh integral are combined to calculate the distribution of the deposited acoustic power. The corresponding simulation was performed with axial/lateral focus shifting at different distances. The distributions of the deposited acoustic power show that linear FM excitation can effectively suppress undesired prefocal grating lobes without compromising focus quality.
Collapse
|
38
|
Wu N, Shen G, Qu X, Wu H, Qiao S, Wang E, Chen Y, Wang H. Design of a Versatile Angle-Rotatable Skull-Shaped Conformal Transcranial Focused Ultrasound Transducer for Noninvasive Brain Therapy. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:116-126. [PMID: 32396086 DOI: 10.1109/tuffc.2020.2993810] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Phase-controlled focused ultrasound transducers have opened up a new way to noninvasively treat brain diseases. However, due to the geometry and the heterogeneous medium of the human skull, the currently used hemispherical transducers cannot guarantee that the ultrasound emitted by the transducer penetrates the skull normally; consequently, the impact of the shear wave on the treatment area has to be considered. The usual approach is to turn off elements in the transducer with excessively large incident angles, but this approach reduces the efficiency of the transducer. This article presents the design of a novel transducer that can be rotated according to the different geometric shapes of the skull. The incident angles of the elements in the transducer are modified so that the effect of the shear wave on the treatment area can be ignored and the efficiency of the transducer is improved. The results of computed tomography (CT) model simulation of nine skulls verify the versatility and feasibility of the new transducer. We believe that this kind of rotatable transducer has clinical and engineering significance.
Collapse
|
39
|
Hanes J, Dobakova E, Majerova P. Brain Drug Delivery: Overcoming the Blood-brain Barrier to Treat Tauopathies. Curr Pharm Des 2020; 26:1448-1465. [PMID: 32178609 DOI: 10.2174/1381612826666200316130128] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Accepted: 02/10/2020] [Indexed: 02/06/2023]
Abstract
Tauopathies are neurodegenerative disorders characterized by the deposition of abnormal tau protein in the brain. The application of potentially effective therapeutics for their successful treatment is hampered by the presence of a naturally occurring brain protection layer called the blood-brain barrier (BBB). BBB represents one of the biggest challenges in the development of therapeutics for central nervous system (CNS) disorders, where sufficient BBB penetration is inevitable. BBB is a heavily restricting barrier regulating the movement of molecules, ions, and cells between the blood and the CNS to secure proper neuronal function and protect the CNS from dangerous substances and processes. Yet, these natural functions possessed by BBB represent a great hurdle for brain drug delivery. This review is concentrated on summarizing the available methods and approaches for effective therapeutics' delivery through the BBB to treat neurodegenerative disorders with a focus on tauopathies. It describes the traditional approaches but also new nanotechnology strategies emerging with advanced medical techniques. Their limitations and benefits are discussed.
Collapse
Affiliation(s)
- Jozef Hanes
- Institute of Neuroimmunology, Slovak Academy of Sciences, Centre of Excellence for Alzheimer's Disease and Related Disorders, Dubravska cesta 9, 845 10 Bratislava, Slovakia
| | - Eva Dobakova
- Institute of Neuroimmunology, Slovak Academy of Sciences, Centre of Excellence for Alzheimer's Disease and Related Disorders, Dubravska cesta 9, 845 10 Bratislava, Slovakia
| | - Petra Majerova
- Institute of Neuroimmunology, Slovak Academy of Sciences, Centre of Excellence for Alzheimer's Disease and Related Disorders, Dubravska cesta 9, 845 10 Bratislava, Slovakia
| |
Collapse
|
40
|
Zhang J, Zhou H, Yang J, Jia J, Niu L, Sun Z, Shi D, Meng L, Qiu W, Wang X, Zheng H, Wang G. Low-intensity pulsed ultrasound ameliorates depression-like behaviors in a rat model of chronic unpredictable stress. CNS Neurosci Ther 2020; 27:233-243. [PMID: 33112507 PMCID: PMC7816209 DOI: 10.1111/cns.13463] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 09/05/2020] [Accepted: 09/24/2020] [Indexed: 12/28/2022] Open
Abstract
Introduction There is an unmet need for better nonpharmaceutical treatments for depression. Low‐intensity pulsed ultrasound (LIPUS) is a novel type of neuromodulation that could be helpful for depressed patients. Objective The goal of this study was to investigate the feasibility and potential mechanisms of LIPUS in the treatment of depression. Methods Chronic unpredictable stress (CUS) was used to generate rats with depression‐like features that were treated with four weeks of LIPUS stimulation of the ventromedial prefrontal cortex. Depression‐like behaviors were assessed with the sucrose preference, forced swim, and open field tests. BDNF/mTORC1 signaling was examined by Western blot to investigate this potential molecular mechanism. The safety of LIPUS was evaluated using hematoxylin‐eosin and Nissl staining. Results Four weeks of LIPUS stimulation significantly increased sucrose preference and reduced forced swim immobility time in CUS rats. LIPUS also partially reversed the molecular effects of CUS that included decreased levels of BDNF, phosphorylated tyrosine receptor kinase B (TrkB), extracellular signal‐regulated kinase (ERK), mammalian target of rapamycin complex 1 (mTORC1), and S6 kinase (S6K). Moreover, histological staining revealed no gross tissue damage. Conclusions Chronic LIPUS stimulation can effectively and safely improve depression‐like behaviors in CUS rats. The underlying mechanisms may be related to enhancement of BDNF/ERK/mTORC1 signaling pathways in the prefrontal cortex (PFC). LIPUS is a promising noninvasive neuromodulation tool that merits further study as a potential treatment for depression.
Collapse
Affiliation(s)
- Jinniu Zhang
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China
| | - Hui Zhou
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Jian Yang
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China.,Key Laboratory for the Neurodegenerative Disorders of the Chinese Ministry of Education, Department of Physiology, Capital Medical University, Beijing, China
| | - Jun Jia
- Advanced Innovation Center for Human Brain Protection, Capital Medical University, Beijing, China
| | - Lili Niu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zuoli Sun
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China
| | - Dandan Shi
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China
| | - Long Meng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Weibao Qiu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xiaomin Wang
- Advanced Innovation Center for Human Brain Protection, Capital Medical University, Beijing, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Gang Wang
- The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China.,Key Laboratory for the Neurodegenerative Disorders of the Chinese Ministry of Education, Department of Physiology, Capital Medical University, Beijing, China
| |
Collapse
|
41
|
Xu L, Lee W, Rotenberg A, Böhlke M, Yoon K, Yoo SS. Localized Disruption of Blood Albumin-Phenytoin Binding Using Transcranial Focused Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1986-1997. [PMID: 32402673 DOI: 10.1016/j.ultrasmedbio.2020.04.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 04/02/2020] [Accepted: 04/10/2020] [Indexed: 06/11/2023]
Abstract
Plasma protein binding (PPB) plays an important role in drug pharmacokinetics, particularly for central nervous system drugs, as PPB affects the blood concentration of unbound drug available to cross the blood-brain barrier (BBB). We report the non-invasive, spatially specific disruption of PPB to phenytoin, an anti-epileptic drug with high affinity to albumin, using 250-kHz focused ultrasound (FUS) delivered in a pulsed manner (55-ms tone burst duration, 4-Hz pulse repetitions). Equilibrium dialysis performed on sonicated phosphate-buffered saline solution containing phenytoin and bovine serum albumin revealed a 27.7% elevation in the unbound phenytoin concentration compared with an unsonicated control. Sonication of a unilateral brain hemisphere in rats (n = 10) after intraperitoneal phenytoin injection revealed increased parenchymal phenytoin uptake compared with the unsonicated hemisphere, without evidence of temperature change or BBB disruption. These findings illustrate the use of FUS as a novel technique for spatially selective disruption of PPB, which may be applied to a wide range of drug-plasma protein interactions.
Collapse
Affiliation(s)
- Linda Xu
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Alexander Rotenberg
- Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Mark Böhlke
- Massachusetts College of Pharmacy and Health Sciences University, Boston, Massachusetts, USA
| | - Kyungho Yoon
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| |
Collapse
|
42
|
Therapeutic Potentials of Localized Blood-Brain Barrier Disruption by Noninvasive Transcranial Focused Ultrasound: A Technical Review. J Clin Neurophysiol 2020; 37:104-117. [PMID: 32142021 DOI: 10.1097/wnp.0000000000000488] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The demands for region-specific, noninvasive therapies for neurologic/psychiatric conditions are growing. The rise of transcranial focused ultrasound technology has witnessed temporary and reversible disruptions of the blood-brain barrier in the brain with exceptional control over the spatial precisions and depth, all in a noninvasive manner. Starting with small animal studies about a decade ago, the technique is now being explored in nonhuman primates and humans for the assessment of its efficacy and safety. The ability to transfer exogenous/endogenous therapeutic agents, cells, and biomolecules across the blood-brain barrier opens up new therapeutic avenues for various neurologic conditions, with a possibility to modulate the excitability of regional brain function. This review addresses the technical fundamentals, sonication parameters, experimental protocols, and monitoring techniques to examine the efficacy/safety in focused ultrasound-mediated blood-brain barrier disruption and discuss its potential translations to clinical use.
Collapse
|
43
|
Sukovich JR, Macoskey JJ, Lundt JE, Gerhardson TI, Hall TL, Xu Z. Real-Time Transcranial Histotripsy Treatment Localization and Mapping Using Acoustic Cavitation Emission Feedback. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:1178-1191. [PMID: 31976885 PMCID: PMC7398266 DOI: 10.1109/tuffc.2020.2967586] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Cavitation events generated during histotripsy therapy generate large acoustic cavitation emission (ACE) signals that can be detected through the skull. This article investigates the feasibility of using these ACE signals, acquired using the elements of a 500-kHz, 256-element hemispherical histotripsy transducer as receivers, to localize and map the cavitation activity in real time through the human skullcap during transcranial histotripsy therapy. The locations of the generated cavitation events predicted using the ACE feedback signals in this study were found to be accurate to within <1.5 mm of the centers of masses detected by optical imaging and found to lie to within the measured volumes of the generated cavitation events in >~80 % of cases. Localization results were observed to be biased in the prefocal direction of the histotripsy array and toward its transverse origin but were only weakly affected by focal steering location. The choice of skullcap and treatment pulse repetition frequency (PRF) were both observed to affect the accuracy of the localization results in the low PRF regime (1-10 Hz), but the localization accuracy was seen to stabilize at higher PRFs (≥10 Hz). Tests of the localization algorithm in vitro, for treatment delivered to a bovine brain sample mounted within the skullcap, revealed good agreement between the ACE feedback-generated treatment map and the morphological characteristics of the treated volume of the brain sample. Localization during experiments was achieved in real time for pulses delivered at rates up to 70 Hz, but benchmark tests indicate that the localization algorithm is scalable, indicating that higher rates are possible with more powerful hardware. The results of this article demonstrate the feasibility of using ACE feedback signals to localize and map transcranially generated cavitation events during histotripsy. Such capability has the potential to greatly simplify transcranial histotripsy treatments, as it may provide a non-MRI-based method for monitoring and localizing transcranial histotripsy treatments in real time.
Collapse
|
44
|
Adams C. HIFU Power Monitoring Using Combined Instantaneous Current and Voltage Measurement. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:239-247. [PMID: 31514135 PMCID: PMC7030945 DOI: 10.1109/tuffc.2019.2941185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
During high-intensity focused ultrasound (HIFU) therapy, it is important that the electrical power delivered to the transducer is monitored to avoid underexposure or overexposure, ensure patient safety, and to protect the transducer itself. Due to ease of measurement, the transducer's potential difference may be as an indicator of power delivery. However, even when a transducer's complex impedance is well characterized at small amplitudes and matching networks are used, voltage-only (VO) monitoring cannot account for the presence of drive waveform distortion, changes to the acoustic path, or damage to the transducer. In this study, combined current and voltage (CCV) is proposed as a magnetic resonance imaging (MRI)-compatible, miniature alternative to bidirectional power couplers, which is compatible with switched amplifiers. For CCV power measurement, current probe data were multiplied by the voltage waveform and integrated in the frequency domain. Transducer efficiency was taken into account to predict acoustic power. The technique was validated with a radiation force balance (RFB). When using a typical HIFU transducer and amplifier, VO predictions and acoustic power had a maximum difference of 20%. However, under the same conditions, CCV only had a maximum difference of 5%. The technique was applied to several lesioning experiments and it was shown that when VO was used as a control between two amplifiers, there was up to a 38% difference in lesion area. This greatly reduced to a maximum of 5% once CCV was used instead. These results demonstrate that CCV can accurately predict real-time electrical power delivery, leading to safer HIFU treatments.
Collapse
Affiliation(s)
- Chris Adams
- Sunnybrook Research Institute, Toronto, Canada
| |
Collapse
|
45
|
Xu R, O'Reilly MA. A Spine-Specific Phased Array for Transvertebral Ultrasound Therapy: Design and Simulation. IEEE Trans Biomed Eng 2020; 67:256-267. [DOI: 10.1109/tbme.2019.2912146] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
46
|
Yang Y, Wang C, Li Y, Huang J, Cai F, Xiao Y, Ma T, Zheng H. Development of Scalable 2D Plane Array for Transcranial Ultrasonic Neuromodulation on Non-Human Primates: An Ex Vivo Study. IEEE Trans Neural Syst Rehabil Eng 2019; 28:361-369. [PMID: 31841414 DOI: 10.1109/tnsre.2019.2959436] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Ultrasonic neuromodulation on large animals, like non-human primates, requires the array transducer to have a good steering ability to arbitrarily stimulate various brain locations. Moreover, due to the different sizes of the animal heads, the array is preferred to be conveniently adjustable to different aperture sizes. To meet these requirements, a scalable 2D plane array, which can consist of up to tens of 256-element square modules, has been designed and fabricated in this study. Arrays with large apertures, consisting of 12 and 48 modules (including 3072 and 12288 elements, respectively), have been assembled and tested. The square modules were driven at a center frequency of 1.04 MHz. The transcranial and steering abilities of the modules were verified in a water tank on an ex vivo macaque skull. A focused beam transmitted by single module could pass through the skull with its peak acoustic pressure reduced to 18.1% of that in the free-field, with an acceptable transverse steering range up to 10 mm. Moreover, a much smaller focal spot was obtained by simultaneous transmission using two vertical-placed modules. Compared to the single module, the focal zone axial size was reduced from 29.7 mm to 3.3 mm, and the "stripes" pattern in the focal zone caused by standing waves was eliminated using a difference-frequency transmitting strategy. Such scalable 2D plane array, which can provide a small-size focal spot and has a large steering range and an acceptable transcranial ability, can be useful in research on ultrasonic neuromodulation on non-human primates.
Collapse
|
47
|
Darrow DP, O'Brien P, Richner TJ, Netoff TI, Ebbini ES. Reversible neuroinhibition by focused ultrasound is mediated by a thermal mechanism. Brain Stimul 2019; 12:1439-1447. [PMID: 31377096 PMCID: PMC6851480 DOI: 10.1016/j.brs.2019.07.015] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Revised: 07/18/2019] [Accepted: 07/21/2019] [Indexed: 01/21/2023] Open
Abstract
BACKGROUND Transcranial focused ultrasound (tFUS) at low intensities has been reported to directly evoke responses and reversibly inhibit function in the central nervous system. While some doubt has been cast on the ability of ultrasound to directly evoke neuronal responses, spatially-restricted transcranial ultrasound has demonstrated consistent, inhibitory effects, but the underlying mechanism of reversible suppression in the central nervous system is not well understood. OBJECTIVE/HYPOTHESIS In this study, we sought to characterize the effect of transcranial, low-intensity, focused ultrasound on the thalamus during somatosensory evoked potentials (SSEP) and investigate the mechanism by modulating the parameters of ultrasound. METHODS TFUS was applied to the ventral posterolateral nucleus of the thalamus of a rodent while electrically stimulating the tibial nerve to induce an SSEP. Thermal changes were also induced through an optical fiber that was image-guided to the same target. RESULTS Focused ultrasound reversibly suppressed SSEPs in a spatially and intensity-dependent manner while remaining independent of duty cycle, peak pressure, or modulation frequency. Suppression was highly correlated and temporally consistent with in vivo temperature changes while producing no pathological changes on histology. Furthermore, stereotactically-guided delivery of thermal energy through an optical fiber produced similar thermal effects and suppression. CONCLUSION We confirm that tFUS predominantly causes neuroinhibition and conclude that the most primary biophysical mechanism is the thermal effect of focused ultrasound.
Collapse
Affiliation(s)
- David P Darrow
- Department of Neurosurgery, University of Minnesota, MMC 96, Room D-429, 420 Delaware St SE, Minneapolis, MN, 55455, USA.
| | - Parker O'Brien
- Department of Electrical and Computer Engineering, University of Minnesota, 7-174 Keller Hall, 200 Union Street Se. Minneapolis, MN, 55455, USA.
| | - Thomas J Richner
- Department of Biomedical Engineering, University of Minnesota, 7-105 Nils Hasselmo Hall, 312 Church St. SE, Minneapolis, MN, 55455, USA.
| | - Theoden I Netoff
- Department of Biomedical Engineering, University of Minnesota, 7-105 Nils Hasselmo Hall, 312 Church St. SE, Minneapolis, MN, 55455, USA.
| | - Emad S Ebbini
- Department of Electrical and Computer Engineering, University of Minnesota, 7-174 Keller Hall, 200 Union Street Se. Minneapolis, MN, 55455, USA.
| |
Collapse
|
48
|
Yoon K, Lee W, Lee JE, Xu L, Croce P, Foley L, Yoo SS. Effects of sonication parameters on transcranial focused ultrasound brain stimulation in an ovine model. PLoS One 2019; 14:e0224311. [PMID: 31648261 PMCID: PMC6812789 DOI: 10.1371/journal.pone.0224311] [Citation(s) in RCA: 69] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 10/10/2019] [Indexed: 01/01/2023] Open
Abstract
Low-intensity focused ultrasound (FUS) has significant potential as a non-invasive brain stimulation modality and novel technique for functional brain mapping, particularly with its advantage of greater spatial selectivity and depth penetration compared to existing non-invasive brain stimulation techniques. As previous studies, primarily carried out in small animals, have demonstrated that sonication parameters affect the stimulation efficiency, further investigation in large animals is necessary to translate this technique into clinical practice. In the present study, we examined the effects of sonication parameters on the transient modification of excitability of cortical and thalamic areas in an ovine model. Guided by anatomical and functional neuroimaging data specific to each animal, 250 kHz FUS was transcranially applied to the primary sensorimotor area associated with the right hind limb and its thalamic projection in sheep (n = 10) across multiple sessions using various combinations of sonication parameters. The degree of effect from FUS was assessed through electrophysiological responses, through analysis of electromyogram and electroencephalographic somatosensory evoked potentials for evaluation of excitatory and suppressive effects, respectively. We found that the modulatory effects were transient and reversible, with specific sonication parameters outperforming others in modulating regional brain activity. Magnetic resonance imaging and histological analysis conducted at different time points after the final sonication session, as well as behavioral observations, showed that repeated exposure to FUS did not damage the underlying brain tissue. Our results suggest that FUS-mediated, non-invasive, region-specific bimodal neuromodulation can be safely achieved in an ovine model, indicating its potential for translation into human studies.
Collapse
Affiliation(s)
- Kyungho Yoon
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Wonhye Lee
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Ji Eun Lee
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Linda Xu
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Phillip Croce
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Lori Foley
- Translational Discovery Laboratory, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
49
|
Wang TR, Bond AE, Dallapiazza RF, Blanke A, Tilden D, Huerta TE, Moosa S, Prada FU, Elias WJ. Transcranial magnetic resonance imaging-guided focused ultrasound thalamotomy for tremor: technical note. Neurosurg Focus 2019; 44:E3. [PMID: 29385914 DOI: 10.3171/2017.10.focus17609] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Although the use of focused ultrasound (FUS) in neurosurgery dates to the 1950s, its clinical utility was limited by the need for a craniotomy to create an acoustic window. Recent technological advances have enabled efficient transcranial delivery of US. Moreover, US is now coupled with MRI to ensure precise energy delivery and monitoring. Thus, MRI-guided transcranial FUS lesioning is now being investigated for myriad neurological and psychiatric disorders. Among the first transcranial FUS treatments is thalamotomy for the treatment of various tremors. The authors provide a technical overview of FUS thalamotomy for tremor as well as important lessons learned during their experience with this emerging technology.
Collapse
Affiliation(s)
| | | | - Robert F Dallapiazza
- Division of Neurosurgery, Toronto Western Hospital University Health Network, Toronto, Ontario, Canada
| | | | | | - Thomas E Huerta
- Department of Radiology, Neuroradiology Division, University of Virginia Health System, Charlottesville, Virginia
| | | | - Francesco U Prada
- Department of Neurological Surgery, and.,Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico C. Besta, Milan, Italy
| | | |
Collapse
|
50
|
Ilyas A, Chen CJ, Ding D, Romeo A, Buell TJ, Wang TR, Kalani MYS, Park MS. Magnetic resonance-guided, high-intensity focused ultrasound sonolysis: potential applications for stroke. Neurosurg Focus 2019; 44:E12. [PMID: 29385918 DOI: 10.3171/2017.11.focus17608] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Stroke is one of the leading causes of death worldwide and a significant source of long-term morbidity. Unfortunately, a substantial number of stroke patients either are ineligible or do not significantly benefit from contemporary medical and interventional therapies. To address this void, investigators recently made technological advances to render transcranial MR-guided, high-intensity focused ultrasound (MRg-HIFU) sonolysis a potential therapeutic option for both acute ischemic stroke (AIS)-as an alternative for patients with emergent large-vessel occlusion (ELVO) who are ineligible for endovascular mechanical thrombectomy (EMT) or as salvage therapy for patients in whom EMT fails-and intracerebral hemorrhage (ICH)-as a neoadjuvant means of clot lysis prior to surgical evacuation. Herein, the authors review the technological principles behind MRg-HIFU sonolysis, its results in in vitro and in vivo stroke models, and its potential clinical applications. As a noninvasive transcranial technique that affords rapid clot lysis, MRg-HIFU thrombolysis may develop into a therapeutic option for patients with AIS or ICH. However, additional studies of transcranial MRg-HIFU are necessary to ascertain the merit of this treatment approach for thrombolysis in both AIS and ICH, as well as its technical limitations and risks.
Collapse
Affiliation(s)
- Adeel Ilyas
- Department of Neurosurgery, University of Alabama at Birmingham, Alabama
| | - Ching-Jen Chen
- Department of Neurological Surgery, University of Virginia Health System, Charlottesville, Virginia; and
| | - Dale Ding
- Department of Neurosurgery, Barrow Neurological Institute, Phoenix, Arizona
| | - Andrew Romeo
- Department of Neurosurgery, University of Alabama at Birmingham, Alabama
| | - Thomas J Buell
- Department of Neurological Surgery, University of Virginia Health System, Charlottesville, Virginia; and
| | - Tony R Wang
- Department of Neurological Surgery, University of Virginia Health System, Charlottesville, Virginia; and
| | - M Yashar S Kalani
- Department of Neurological Surgery, University of Virginia Health System, Charlottesville, Virginia; and
| | - Min S Park
- Department of Neurological Surgery, University of Virginia Health System, Charlottesville, Virginia; and
| |
Collapse
|