1
|
Jang M, Gupta A, Kovanlikaya A, Scholl JE, Zun Z. High-resolution anatomical imaging of the fetal brain with a reduced field of view using outer volume suppression. Magn Reson Med 2024; 92:1556-1567. [PMID: 38702999 PMCID: PMC11262973 DOI: 10.1002/mrm.30147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 04/04/2024] [Accepted: 04/19/2024] [Indexed: 05/06/2024]
Abstract
PURPOSE To achieve high-resolution fetal brain anatomical imaging without introducing image artifacts by reducing the FOV, and to demonstrate improved image quality compared to conventional full-FOV fetal brain imaging. METHODS Reduced FOV was achieved by applying outer volume suppression (OVS) pulses immediately prior to standard single-shot fast spin echo (SSFSE) imaging. In the OVS preparation, a saturation RF pulse followed by a gradient spoiler was repeated three times with optimized flip-angle weightings and a variable spoiler scheme to enhance signal suppression. Simulations and phantom and in-vivo experiments were performed to evaluate OVS performance. In-vivo high-resolution SSFSE images acquired using the proposed approach were compared with conventional and high-resolution SSFSE images with a full FOV, using image quality scores assessed by neuroradiologists and calculated image metrics. RESULTS Excellent signal suppression in the saturation bands was confirmed in phantom and in-vivo experiments. High-resolution SSFSE images with a reduced FOV acquired using OVS demonstrated the improved depiction of brain structures without significant motion and blurring artifacts. The proposed method showed the highest image quality scores in the criteria of sharpness, contrast, and artifact and was selected as the best method based on overall image quality. The calculated image sharpness and tissue contrast ratio were also the highest with the proposed method. CONCLUSION High-resolution fetal brain anatomical images acquired using a reduced FOV with OVS demonstrated improved image quality both qualitatively and quantitatively, suggesting the potential for enhanced diagnostic accuracy in detecting fetal brain abnormalities in utero.
Collapse
Affiliation(s)
- MinJung Jang
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA
| | - Ajay Gupta
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA
| | - Arzu Kovanlikaya
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA
| | - Jessica E. Scholl
- Department of Obstetrics and Gynecology, Weill Cornell Medicine, New York, New York, USA
| | - Zungho Zun
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA
| |
Collapse
|
2
|
Takayama Y, Sato K, Tanaka S, Murayama R, Jingu R, Yoshimitsu K. Effectiveness of deep learning-based reconstruction for improvement of image quality and liver tumor detectability in the hepatobiliary phase of gadoxetic acid-enhanced magnetic resonance imaging. Abdom Radiol (NY) 2024; 49:3450-3463. [PMID: 38755452 DOI: 10.1007/s00261-024-04374-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 05/04/2024] [Accepted: 05/04/2024] [Indexed: 05/18/2024]
Abstract
PURPOSE To evaluate the effectiveness of deep learning-based reconstruction (DLR) in improving image quality and tumor detectability of isovoxel high-resolution breath-hold fat-suppressed T1-weighted imaging (HR-BH-FS-T1WI) in the hepatobiliary phase (HBP) of Gadoxetic acid-enhanced magnetic resonance imaging (Gd-EOB-MRI). MATERIALS AND METHODS This retrospective evaluated 42 patients with 98 liver tumors who underwent Gd-EOB-MRI between March 2023 and May 2023 using three techniques based on HBP imaging: isovoxel HR-BH-FS-T1WI reconstructed (1) with DLR (BH-DLR +) and (2) without DLR (BH-DLR -) and (3) HR-FS-T1WI scanned with a free-breathing technique using a navigator-echo-triggered technique and DLR (Navi-DLR +). The three techniques were qualitatively and quantitatively compared by the Friedman test and the Bonferroni post-hoc test. Tumor detectability was compared using the McNemar test. RESULTS BH-DLR + (3.85, average score of two radiologists) showed significantly better qualitative scores for image noise than BH-DLR - (2.84) and Navi-DLR + (3.37) (p < 0.0167), and Navi-DLR + showed significantly better scores than BH-DLR - (p < 0.0167). BH-DLR + (3.77) and BH-DLR - (3.77) showed significantly better qualitative scores for respiratory motion artifact than Navi-DLR + (2.75) (p < 0.0167), but there was no significant difference in scores between BH-DLR + and BH-DLR - (p > 0.0167). BH-DLR + (0.32) and Navi-DLR + (0.33) showed significantly higher lesion-to-nonlesion CR than BH-DLR - (0.29) (p < 0.0167), but there was no significant difference in lesion-to-nonlesion CR between BH-DLR + and Navi-DLR + (p > 0.0167). BH-DLR + (89.8%) showed significantly better tumor detectability than BH-DLR - (76.0%) and Navi-DLR + (77.6%) (p < 0.05). CONCLUSION The use of DLR for isovoxel HR-BH-FS-T1WI was effective in improving image quality and tumor detectability.
Collapse
Affiliation(s)
- Yukihisa Takayama
- Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka City, Fukuoka, 814-0180, Japan.
| | - Keisuke Sato
- Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka City, Fukuoka, 814-0180, Japan
| | - Shinji Tanaka
- Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka City, Fukuoka, 814-0180, Japan
| | - Ryo Murayama
- Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka City, Fukuoka, 814-0180, Japan
| | - Ryotaro Jingu
- Radiology Center, Fukuoka University Hospital, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka City, Fukuoka, 814-0180, Japan
| | - Kengo Yoshimitsu
- Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-Ku, Fukuoka City, Fukuoka, 814-0180, Japan
| |
Collapse
|
3
|
Wang Y, Cui Y, Dai J, Ni S, Zhang T, Chen X, Jiang Q, Cheng Y, Ma Y, Li T, Xiao Y. Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy. Korean J Radiol 2024; 25:913-923. [PMID: 39344548 PMCID: PMC11444853 DOI: 10.3348/kjr.2024.0177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 07/30/2024] [Accepted: 08/02/2024] [Indexed: 10/01/2024] Open
Abstract
OBJECTIVE To prospectively compare single-shot (SS) echo-planar imaging (EPI) and field-of-view optimized and constrained undistorted single-shot multiplexed sensitivity-encoding (FOCUS MUSE) for diffusion-weighted imaging (DWI) in evaluating thyroid-associated ophthalmopathy (TAO). MATERIALS AND METHODS SS EPI and FOCUS MUSE DWIs were obtained from 39 patients with TAO (18 male; mean ± standard deviation: 48.3 ± 13.3 years) and 26 healthy controls (9 male; mean ± standard deviation: 43.0 ± 18.5 years). Two radiologists scored the visual image quality using a 4-point Likert scale. The image quality score, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) of extraocular muscles (EOMs) were compared between the two DWIs. Differences in the ADC of EOMs were also evaluated. The performance of discriminating active from inactive TAO was assessed using receiver operating characteristic curves. The correlation between ADC and clinical activity score (CAS) was analyzed using Spearman correlation. RESULTS Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated significantly higher image quality scores (P < 0.001), a higher SNR and CNR on the lateral rectus muscle (LRM) and medial rectus muscle (MRM) (P < 0.05), and a non-significant difference in the ADC of the LRM and MRM. Active TAO showed higher ADC than inactive TAO and healthy controls with both SS EPI and FOCUS MUSE DWIs (P < 0.001). Inactive TAO and healthy controls did not show a significant ADC difference with both DWIs. Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated better discrimination of active from inactive TAO (AUC: 0.925 vs. 0.779; P = 0.007). The ADC was significantly correlated with CAS in SS EPI DWI (r = 0.391, P < 0.001) and FOCUS MUSE DWI (r = 0.645, P < 0.001). CONCLUSION FOCUS MUSE DWI provides better images for evaluating EOMs and better performance in diagnosing active TAO than SS EPI DWI. The application of FOCUS MUSE will facilitate the DWI evaluation of TAO.
Collapse
Affiliation(s)
- YunMeng Wang
- Graduate School of Bengbu Medical University, Bengbu, China
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - YuanYuan Cui
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | | | - ShuangShuang Ni
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - TianRan Zhang
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - Xin Chen
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - QinLing Jiang
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - YuXin Cheng
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - YiChuan Ma
- Department of Radiology, The First Affiliated Hospital of Bengbu Medical University, Bengbu, China
| | - Tuo Li
- Department of Endocrinology, Changzheng Hospital, Shanghai, China
| | - Yi Xiao
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China.
| |
Collapse
|
4
|
Lee PK, Hess JJ, Gomella AA, Loening AM, Hargreaves BA. A diffusion-prepared reduced FOV sequence for prostate MRI near metallic implants. Magn Reson Med 2024. [PMID: 39221478 DOI: 10.1002/mrm.30280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 08/12/2024] [Accepted: 08/12/2024] [Indexed: 09/04/2024]
Abstract
PURPOSE To enable diffusion weighted imaging in prostate patients with metallic total hip replacements in clinically feasible scan times for prostate cancer screening, and avoid distortion and dropout artifacts present in the conventionally used Echo Planar Imaging (EPI). METHODS A reduced field of view (FOV) diffusion-prepared sequence that is robust to the B 0 $$ {\kern0em }_0 $$ inhomogeneities produced by total hip replacements was achieved using high radiofrequency (RF) bandwidth pulses and manipulation for stimulated echo pathways. The reduced FOV along the A/P direction was obtained using slice-select gradient reversal, and the prepared magnetization was imaged with a three-dimensional RF-spoiled gradient echo readout. The sequence was validated in phantom experiments, in vivo in healthy volunteers with and without total hip replacements, and in vivo in patients undergoing a standard MRI prostate exam. RESULTS The proposed sequence is robust to shading and distortion artifacts that are encountered by standard diffusion-weighted EPI in the presence of moderate off-resonance. Apparent diffusion coefficient estimates obtained by the proposed sequence were comparable to those obtained with diffusion-weighted EPI. CONCLUSION Acquisition of distortionless diffusion weighted images of the prostate is feasible in patients with total hip replacements on conventional, whole-body 3T MRI, using a b-value of 800s / mm 2 $$ \mathrm{s}/{\mathrm{mm}}^2 $$ and nominal resolution of 1.7× $$ \times $$ 1.7× $$ \times $$ 4 mm3 in scan times of 6 min.
Collapse
Affiliation(s)
- Philip K Lee
- Radiology, Stanford University, Stanford, California, USA
| | - Jeremiah J Hess
- Radiology, Stanford University, Stanford, California, USA
- Bioengineering, Stanford University, Stanford, California, USA
| | | | | | - Brian A Hargreaves
- Radiology, Stanford University, Stanford, California, USA
- Bioengineering, Stanford University, Stanford, California, USA
- Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
5
|
Li Y, Middleton DM, Chen A, Shinohara RT, Krisa L, Faro SH, Mulcahey MJ, Mohamed FB. Harmonization of Longitudinal Diffusion Tensor Imaging Data of the Pediatric Cervical and Thoracic Spinal Cord at 3T Using Longitudinal ComBat. RESEARCH SQUARE 2024:rs.3.rs-4536023. [PMID: 39011114 PMCID: PMC11247925 DOI: 10.21203/rs.3.rs-4536023/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/17/2024]
Abstract
Diffusion tensor imaging (DTI) of the spinal cord has been extensively used to identify biomarkers for spinal cord pathology. Previously, the longitudinal ComBat (longComBat) technique was examined to reduce scanner effects in multi-site, multi-scanner spinal cord DTI data. This study aimed to assess its effectiveness on longitudinal scans using a single-scanner pediatric dataset, including healthy and spinal cord injury (SCI) subjects. Two identical datasets were collected from 42 healthy and 27 SCI subjects with a 2-hour interval between scans on a 3T Siemens MRI scanner. Axial DTI images of the entire cervical and thoracic spinal cord were obtained, and various average diffusion tensor metrics (FA, MD, RD, & AD) were measured at each vertebral level. Pearson correlation and intraclass correlation coefficients were used to evaluate inter- and intra-subject agreement pre- and post-harmonization. Minimal improvement in agreement was observed with the mean square residual (MSR) model, while the restricted maximum likelihood estimator (REML) model showed reduced intra-subject agreement in all the tensor metrics. The significant variability between longitudinal DTI scans within a single scanner was likely due to physiological motion rather than scanner effects. Post-harmonization using the longComBat MSR model showed limited improvement in agreement.
Collapse
Affiliation(s)
- Yutong Li
- Thomas Jefferson University, Sidney Kimmel Medical College
| | | | - Andrew Chen
- University of Pennsylvania Perelman School of Medicine
| | | | | | | | | | | |
Collapse
|
6
|
Shi J, Lin J, Zhou X, Yin N, Wu L, Yu M, Xu M. Comparison of Reduced and Full Field of View in Diffusion-Weighted MRI on Image Quality: A Meta-Analysis. J Magn Reson Imaging 2024. [PMID: 38896049 DOI: 10.1002/jmri.29487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 06/01/2024] [Accepted: 06/03/2024] [Indexed: 06/21/2024] Open
Abstract
BACKGROUND Reduced field of view (rFOV) diffusion-weighted imaging (DWI) in MRI shows potential for enhanced image quality compared with traditional full field of view (fFOV) DWI. Evaluating rFOV DWI's impact on image quality is important for clinical adoption. OBJECTIVE To assess the efficacy of rFOV DWI in improving image quality, focusing on artifact reduction, signal-to-noise ratio (SNR) improvement, and lesion detectability. STUDY TYPE Meta-analysis. POPULATION Systematic literature search was conducted in PubMed, Embase, the Cochrane Library, and Web of Science ending in January 2024. Thirteen studies with 765 participants focusing on DWI quality using rFOV was analyzed. FIELD STRENGTH/SEQUENCE SS-EPI, Rtr-SS-EPI, 2D-SS-EPI at 3.0 T. ASSESSMENT Two investigators performed the data extraction. QUADAS-2 assessed bias. The image quality assessment of rFOV and fFOV DWI were compared. STATISTICAL TESTS Standardized mean difference (SMD) was utilized to evaluate and standardize MRI image quality. Heterogeneity was assessed using the I2 statistic and publication bias was evaluated with Egger's test. RESULTS The QUADAS-2 analysis revealed that most studies exhibited a low risk of bias and minimal concerns regarding applicability. Statistical analysis indicated that rFOV DWI yielded higher subjective image quality scores (SMD = 0.535, 95% CI: 0.339, 0.731, I2 = 45.7%) compared with fFOV DWI and was more effective in reducing artifacts (SMD = 0.44, 95% CI: 0.209, 0.672, I2 = 42.3%) than fFOV DWI. However, a decrease in SNR was noted with rFOV DWI (SMD = -0.670, 95% CI: -1.187 to -0.152, I2 = 87.9%). Additionally, rFOV DWI demonstrated enhancements in lesion visibility (SMD = 0.432, 95% CI: -1.187, -0.152, I2 = 53.1%) and anatomical details (SMD = 0.598, 95% CI: 0.121, 1.075, I2 = 90.8%). DATA CONCLUSION rFOV DWI enhances MRI image quality by reducing artifacts and improving lesion visibility with a SNR trade-off. EVIDENCE LEVEL 3 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Jingjing Shi
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| | - Jie Lin
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| | - Xinbin Zhou
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
- Department of Cardiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
| | - Ningbo Yin
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| | - Liyi Wu
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| | - Mei Yu
- The Xiaoshan Hospital Affiliated of Wenzhou Medical University, Xiaoshan First People's Hospital, Hangzhou, China
| | - Maosheng Xu
- Department of Radiology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, China
- The First School of Clinical Medicine of Zhejiang Chinese Medical University, Hangzhou, China
| |
Collapse
|
7
|
Kanematsu Y, Kanazawa Y, Shimada K, Korai M, Miyamoto T, Sogabe S, Ishihara M, Yamaguchi I, Oya T, Yamamoto N, Yamamoto Y, Miyoshi M, Harada M, Takagi Y. Characterization of carotid plaques using chemical exchange saturation transfer imaging. Neuroradiology 2024:10.1007/s00234-024-03401-3. [PMID: 38866959 DOI: 10.1007/s00234-024-03401-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Accepted: 06/06/2024] [Indexed: 06/14/2024]
Abstract
PURPOSE The preoperative assessment of carotid plaques is necessary to render revascularization safe and effective. The aim of this study is to evaluate the usefulness of chemical exchange saturation transfer (CEST)-MRI, particularly amide proton transfer (APT) imaging as a preoperative carotid plaque diagnostic tool. METHODS We recorded the APT signal intensity on concentration maps of 34 patients scheduled for carotid endarterectomy. Plaques were categorized into group A (APT signal intensity ≥ 1.90 E-04; n = 12) and group B (APT signal intensity < 1.90 E-04; n = 22). Excised plaques were subjected to histopathological assessment and, using the classification promulgated by the American Heart Association, they were classified as intraplaque hemorrhage-positive [type VI-positive (tVI+)] and -negative [no intraplaque hemorrhage (tVI-)]. RESULTS Of the 34 patients, 22 (64.7%) harbored tVI+- and 12 (35.3%) had tVI- plaques. The median APT signals were significantly higher in tVI+- than tIVI- patients (2.43 E-04 (IQR = 0.98-4.00 E-04) vs 0.54 E-04 (IQR = 0.14-1.09 E-04), p < .001). Histopathologically, the number of patients with tVI+ plaques was significantly greater in group A (100%, n = 12) than group B (45%, n = 22) (p < .01). The number of symptomatic patients or asymptomatic patients with worsening stenosis was also significantly greater in group A than group B (75% vs 36%, p < .01). CONCLUSION In unstable plaques with intraplaque hemorrhage and in patients with symptoms or progressive stenosis, the ATP signals were significantly elevated. CEST-MRI studies has the potential for the preoperative assessment of the plaques' characteristics.
Collapse
Affiliation(s)
- Yasuhisa Kanematsu
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan.
| | - Yuki Kanazawa
- Department of Medical Imaging and Physics, Tokushima University Graduate School of Biomedical Sciences, Tokushima, Japan
| | - Kenji Shimada
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Masaaki Korai
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Takeshi Miyamoto
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Shu Sogabe
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Manabu Ishihara
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Izumi Yamaguchi
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Takeshi Oya
- Department of Molecular Pathology, Tokushima University Graduate School of Biomedical Sciences, Japan, Tokushima
| | - Nobuaki Yamamoto
- Department of Clinical Neuroscience, Tokushima University Graduate School of Biomedical Sciences, Japan, Tokushima
| | - Yuki Yamamoto
- Department of Clinical Neuroscience, Tokushima University Graduate School of Biomedical Sciences, Japan, Tokushima
| | - Mitsuharu Miyoshi
- Global MR Clinical Solutions and Research Collaborations, GE HealthCare, Japan, Hino
| | - Masafumi Harada
- Department of Radiology, Tokushima University Graduate School of Biomedical Sciences, Japan, Tokushima
| | - Yasushi Takagi
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| |
Collapse
|
8
|
Zhang X, Xu X, Wang Y, Zhang J, Hu M, Zhang J, Zhang L, Wang S, Li Y, Zhao X, Chen Y. Reduced field-of-view DWI based on deep learning reconstruction improving diagnostic accuracy of VI-RADS for evaluating muscle invasion. Insights Imaging 2024; 15:139. [PMID: 38853219 PMCID: PMC11162985 DOI: 10.1186/s13244-024-01686-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Accepted: 04/02/2024] [Indexed: 06/11/2024] Open
Abstract
OBJECTIVES To investigate whether reduced field-of-view (rFOV) diffusion-weighted imaging (DWI) with deep learning reconstruction (DLR) can improve the accuracy of evaluating muscle invasion using VI-RADS. METHODS Eighty-six bladder cancer participants who were evaluated by conventional full field-of-view (fFOV) DWI, standard rFOV (rFOVSTA) DWI, and fast rFOV with DLR (rFOVDLR) DWI were included in this prospective study. Tumors were categorized according to the vesical imaging reporting and data system (VI-RADS). Qualitative image quality scoring, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and ADC value were evaluated. Friedman test with post hoc test revealed the difference across the three DWIs. Receiver operating characteristic analysis was performed to calculate the areas under the curve (AUCs). RESULTS The AUC of the rFOVSTA DWI and rFOVDLR DWI were higher than that of fFOV DWI. rFOVDLR DWI reduced the acquisition time from 5:02 min to 3:25 min, and showed higher scores in overall image quality with higher CNR and SNR, compared to rFOVSTA DWI (p < 0.05). The mean ADC of all cases of rFOVSTA DWI and rFOVDLR DWI was significantly lower than that of fFOV DWI (all p < 0.05). There was no difference in mean ADC value and the AUC for evaluating muscle invasion between rFOVSTA DWI and rFOVDLR DWI (p > 0.05). CONCLUSIONS rFOV DWI with DLR can improve the diagnostic accuracy of fFOV DWI for evaluating muscle invasion. Applying DLR to rFOV DWI reduced the acquisition time and improved overall image quality while maintaining ADC value and diagnostic accuracy. CRITICAL RELEVANCE STATEMENT The diagnostic performance and image quality of full field-of-view DWI, reduced field-of-view (rFOV) DWI with and without DLR were compared. DLR would benefit the wide clinical application of rFOV DWI by reducing the acquisition time and improving the image quality. KEY POINTS Deep learning reconstruction (DLR) can reduce scan time and improve image quality. Reduced field-of-view (rFOV) diffusion-weighted imaging (DWI) with DLR showed better diagnostic performances than full field-of-view DWI. There was no difference of diagnostic accuracy between rFOV DWI with DLR and standard rFOV DWI.
Collapse
Affiliation(s)
- Xinxin Zhang
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Xiaojuan Xu
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Yichen Wang
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Jie Zhang
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Mancang Hu
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Jin Zhang
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Lianyu Zhang
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Sicong Wang
- GE Healthcare, MR Research China, Daxing district, Tongji south road No1, Beijing, 100176, China
| | - Yi Li
- School of Statistics and Mathematics, Nanjing Audit University, Nanjing, 211815, China
| | - Xinming Zhao
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.
| | - Yan Chen
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.
| |
Collapse
|
9
|
Zhu A, Tarasek M, Hua Y, Fiveland E, Maier SE, Mazaheri Y, Fung M, Westin CF, Yeo DT, Szczepankiewicz F, Tempany C, Akin O, Foo TK. Human prostate MRI at ultrahigh-performance gradient: A feasibility study. Magn Reson Med 2024; 91:640-648. [PMID: 37753628 PMCID: PMC10841413 DOI: 10.1002/mrm.29874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 09/02/2023] [Accepted: 09/06/2023] [Indexed: 09/28/2023]
Abstract
PURPOSE To demonstrate the technical feasibility and the value of ultrahigh-performance gradient in imaging the prostate in a 3T MRI system. METHODS In this local institutional review board-approved study, prostate MRI was performed on 4 healthy men. Each subject was scanned in a prototype 3T MRI system with a 42-cm inner-diameter gradient coil that achieves a maximum gradient amplitude of 200 mT/m and slew rate of 500 T/m/s. PI-RADS V2.1-compliant axial T2 -weighted anatomical imaging and single-shot echo planar DWI at standard gradient of 70 mT/m and 150 T/m/s were obtained, followed by DWI at maximum performance (i.e., 200 mT/m and 500 T/m/s). In comparison to state-of-the-art clinical whole-body MRI systems, the high slew rate improved echo spacing from 1020 to 596 μs and, together with a high gradient amplitude for diffusion encoding, TE was reduced from 55 to 36 ms. RESULTS In all 4 subjects (waist circumference = 81-91 cm, age = 45-65 years), no peripheral nerve stimulation sensation was reported during DWI. Reduced image distortion in the posterior peripheral zone prostate gland and higher signal intensity, such as in the surrounding muscle of high-gradient DWI, were noted. CONCLUSION Human prostate MRI at simultaneously high gradient amplitude of 200 mT/m and slew rate of 500 T/m/s is feasible, demonstrating that improved gradient performance can address image distortion and T2 decay-induced SNR issues for in vivo prostate imaging.
Collapse
Affiliation(s)
- Ante Zhu
- GE Research, Niskayuna, New York, United States
| | | | - Yihe Hua
- GE Research, Niskayuna, New York, United States
| | | | - Stephan E. Maier
- Brigham and Women’s Hospital, Boston, Massachusetts, United States
| | - Yousef Mazaheri
- Memorial Sloan Kettering Cancer Center, New York, New York, United States
| | | | | | | | | | - Clare Tempany
- Brigham and Women’s Hospital, Boston, Massachusetts, United States
| | - Oguz Akin
- Memorial Sloan Kettering Cancer Center, New York, New York, United States
| | | |
Collapse
|
10
|
Musall BC, Rauch DE, Mohamed RM, Panthi B, Boge M, Candelaria RP, Chen H, Guirguis MS, Hunt KK, Huo L, Hwang KP, Korkut A, Litton JK, Moseley TW, Pashapoor S, Patel MM, Reed BJ, Scoggins ME, Son JB, Tripathy D, Valero V, Wei P, White JB, Whitman GJ, Xu Z, Yang WT, Yam C, Adrada BE, Ma J. Diffusion Tensor Imaging for Characterizing Changes in Triple-Negative Breast Cancer During Neoadjuvant Systemic Therapy. J Magn Reson Imaging 2024:10.1002/jmri.29267. [PMID: 38294179 PMCID: PMC11289164 DOI: 10.1002/jmri.29267] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 01/18/2024] [Accepted: 01/18/2024] [Indexed: 02/01/2024] Open
Abstract
BACKGROUND Assessment of treatment response in triple-negative breast cancer (TNBC) may guide individualized care for improved patient outcomes. Diffusion tensor imaging (DTI) measures tissue anisotropy and could be useful for characterizing changes in the tumors and adjacent fibroglandular tissue (FGT) of TNBC patients undergoing neoadjuvant systemic treatment (NAST). PURPOSE To evaluate the potential of DTI parameters for prediction of treatment response in TNBC patients undergoing NAST. STUDY TYPE Prospective. POPULATION Eighty-six women (average age: 51 ± 11 years) with biopsy-proven clinical stage I-III TNBC who underwent NAST followed by definitive surgery. 47% of patients (40/86) had pathologic complete response (pCR). FIELD STRENGTH/SEQUENCE 3.0 T/reduced field of view single-shot echo-planar DTI sequence. ASSESSMENT Three MRI scans were acquired longitudinally (pre-treatment, after 2 cycles of NAST, and after 4 cycles of NAST). Eleven histogram features were extracted from DTI parameter maps of tumors, a peritumoral region (PTR), and FGT in the ipsilateral breast. DTI parameters included apparent diffusion coefficients and relative diffusion anisotropies. pCR status was determined at surgery. STATISTICAL TESTS Longitudinal changes of DTI features were tested for discrimination of pCR using Mann-Whitney U test and area under the receiver operating characteristic curve (AUC). A P value <0.05 was considered statistically significant. RESULTS 47% of patients (40/86) had pCR. DTI parameters assessed after 2 and 4 cycles of NAST were significantly different between pCR and non-pCR patients when compared between tumors, PTRs, and FGTs. The median surface/average anisotropy of the PTR, measured after 2 and 4 cycles of NAST, increased in pCR patients and decreased in non-pCR patients (AUC: 0.78; 0.027 ± 0.043 vs. -0.017 ± 0.042 mm2 /s). DATA CONCLUSION Quantitative DTI features from breast tumors and the peritumoral tissue may be useful for predicting the response to NAST in TNBC. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 4.
Collapse
Affiliation(s)
- Benjamin C. Musall
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - David E. Rauch
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Rania M.M. Mohamed
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Bikash Panthi
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Medine Boge
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Rosalind P. Candelaria
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Huiqin Chen
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Mary S. Guirguis
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Kelly K. Hunt
- Department of Breast Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Lei Huo
- Department of Pathology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Ken-Pin Hwang
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Anil Korkut
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jennifer K. Litton
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Tanya W. Moseley
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- Department of Breast Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Sanaz Pashapoor
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Miral M. Patel
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Brandy J. Reed
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Marion E. Scoggins
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jong Bum Son
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Debu Tripathy
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Vicente Valero
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Peng Wei
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jason B. White
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Gary J. Whitman
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Zhan Xu
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Wei T. Yang
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Clinton Yam
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Beatriz E. Adrada
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jingfei Ma
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
11
|
Bian W, Wang L, Li J, Cui S, Wu W, Fan R, Niu J. Comparison of reduced field-of-view DWI and conventional DWI techniques for the assessment of lumbar bone marrow infiltration in patients with acute leukemia. Front Oncol 2024; 13:1321080. [PMID: 38260859 PMCID: PMC10800863 DOI: 10.3389/fonc.2023.1321080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 11/28/2023] [Indexed: 01/24/2024] Open
Abstract
Objectives To compare the imaging quality, apparent diffusion coefficient (ADC), and the value of assessing bone marrow infiltration between reduced field-of-view diffusion-weighted imaging (r-FOV DWI) and conventional DWI in the lumbar spine of acute leukemia (AL). Methods Patients with newly diagnosed AL were recruited and underwent both r-FOV DWI and conventional DWI in the lumbar spine. Two radiologists evaluated image quality scores using 5-Likert-type scales qualitatively and measured signal-to-noise ratio (SNR), contrast-to-noise (CNR), signal intensity ratio (SIR), and ADC quantitatively. Patients were divided into hypo- and normocellular group, moderately hypercellular group, and severely hypercellular group according to bone marrow cellularity (BMC) obtained from bone marrow biopsies. The image quality parameters and ADC value between the two sequences were compared. One-way analysis of variance followed by LSD post hoc test was used for the comparisons of the ADC values among the three groups. The performance of ADC obtained with r-FOV DWI (ADCr) and conventional DWI(ADCc) in evaluating BMC and their correlations with BMC and white blood cells (WBC) were analyzed and compared. Results 71 AL patients (hypo- and normocellular: n=20; moderately hypercellular: n=19; severely hypercellular: n=32) were evaluated. The image quality scores, CNR, SIR, and ADC value of r-FOV DWI were significantly higher than those of conventional DWI (all p<0.05), and the SNR of r-FOV DWI was significantly lower (p<0.001). ADCr showed statistical differences in all pairwise comparisons among the three groups (all p<0.05), while ADCc showed significant difference only between hypo- and normocellular group and severely hypercellular group (p=0.014). The performance of ADCr in evaluating BMC (Z=2.380, p=0.017) and its correlations with BMC (Z=-2.008, p = 0.045) and WBC (Z=-2.022, p = 0.043) were significantly higher than those of ADCc. Conclusion Compared with conventional DWI, r-FOV DWI provides superior image quality of the lumbar spine in AL patients, thus yielding better performance in assessing bone marrow infiltration.
Collapse
Affiliation(s)
- Wenjin Bian
- Department of Medical Imaging, Shanxi Medical University, Taiyuan, Shanxi, China
- Department of Radiology, The Second Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Luyao Wang
- Department of Medical Imaging, Shanxi Medical University, Taiyuan, Shanxi, China
| | - Jianting Li
- Department of Radiology, The Second Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Sha Cui
- Department of Radiology, The Second Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Wenqi Wu
- Department of Radiology, The Second Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Rong Fan
- Department of Radiology, The Second Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Jinliang Niu
- Department of Radiology, The Second Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| |
Collapse
|
12
|
Zaid Alkilani A, Çukur T, Saritas EU. FD-Net: An unsupervised deep forward-distortion model for susceptibility artifact correction in EPI. Magn Reson Med 2024; 91:280-296. [PMID: 37811681 DOI: 10.1002/mrm.29851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 07/18/2023] [Accepted: 08/15/2023] [Indexed: 10/10/2023]
Abstract
PURPOSE To introduce an unsupervised deep-learning method for fast and effective correction of susceptibility artifacts in reversed phase-encode (PE) image pairs acquired with echo planar imaging (EPI). METHODS Recent learning-based correction approaches in EPI estimate a displacement field, unwarp the reversed-PE image pair with the estimated field, and average the unwarped pair to yield a corrected image. Unsupervised learning in these unwarping-based methods is commonly attained via a similarity constraint between the unwarped images in reversed-PE directions, neglecting consistency to the acquired EPI images. This work introduces a novel unsupervised deep Forward-Distortion Network (FD-Net) that predicts both the susceptibility-induced displacement field and the underlying anatomically correct image. Unlike previous methods, FD-Net enforces the forward-distortions of the correct image in both PE directions to be consistent with the acquired reversed-PE image pair. FD-Net further leverages a multiresolution architecture to maintain high local and global performance. RESULTS FD-Net performs competitively with a gold-standard reference method (TOPUP) in image quality, while enabling a leap in computational efficiency. Furthermore, FD-Net outperforms recent unwarping-based methods for unsupervised correction in terms of both image and field quality. CONCLUSION The unsupervised FD-Net method introduces a deep forward-distortion approach to enable fast, high-fidelity correction of susceptibility artifacts in EPI by maintaining consistency to measured data. Therefore, it holds great promise for improving the anatomical accuracy of EPI imaging.
Collapse
Affiliation(s)
- Abdallah Zaid Alkilani
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Tolga Çukur
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
- Neuroscience Graduate Program, Bilkent University, Ankara, Turkey
| | - Emine Ulku Saritas
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
- Neuroscience Graduate Program, Bilkent University, Ankara, Turkey
| |
Collapse
|
13
|
Tounekti S, Alizadeh M, Middleton D, Harrop JS, Hiba B, Krisa L, Mekkaoui C, Mohamed FB. Metal artifact reduction around cervical spine implant using diffusion tensor imaging at 3T: A phantom study. Magn Reson Imaging 2024; 105:57-66. [PMID: 37939969 PMCID: PMC10841892 DOI: 10.1016/j.mri.2023.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 11/04/2023] [Indexed: 11/10/2023]
Abstract
PURPOSE Diffusion MRI continues to play a key role in non-invasively assessing spinal cord integrity and pre-operative injury evaluation. However, post-operative Diffusion Tensor Imaging (DTI) acquisition of patients with metal implants results in severe geometric distortion. We propose and demonstrate a method to alleviate the technical challenges facing the acquisition of DTI on post-operative cases and longitudinal evaluation of therapeutics. MATERIAL AND METHODS The described technique is based on the combination of the reduced Field-Of-View (rFOV) strategy and the phase segmented EPI, termed rFOV-PS-EPI. A custom-built phantom based on a cervical spine model with metal implants was used to collect DTI data at 3 Tesla scanner using: rFOV-PS-EPI, reduced Field-Of-View single-shot EPI (rFOV-SS-EPI), and conventional full FOV techniques including SS-EPI, PS-EPI, and readout-segmented EPI (RS-EPI). Geometric distortion, SNR, and signal void were assessed to evaluate images and compare the sequences. A two-sample t-test was performed with p-value of 0.05 or less to indicate statistical significance. RESULTS The reduced FOV techniques showed better capability to reduce distortions compared to the Full FOV techniques. The rFOV-PS-EPI method provided DTI images of the phantom at the level of the hardware whereas the conventional rFOV-SS-EPI is useful only when the metal is approximately 20 mm away. In addition, compared to the rFOV-SS-EPI technique, the suggested approach produced smaller signal voids area as well as significantly reduced geometric distortion in Circularity (p < 0.005) and Eccentricity (p < 0.005) measurements. No statistically significant differences were found for these geometric distortion measurements between the rFOV-PS-EPI DTI sequence and conventional structural T2 images (p > 0.05). CONCLUSION The combination of rFOV and a phase-segmented acquisition approach is effective for reducing metal-induced distortions in DTI scan on spinal cord with metal hardware at 3 T.
Collapse
Affiliation(s)
- Slimane Tounekti
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA.
| | - Mahdi Alizadeh
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, PA, USA
| | - Devon Middleton
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA
| | - James S Harrop
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, PA, USA
| | - Bassem Hiba
- Institut des Sciences Cognitives, CNRS UMR 5229, Université Lyon 1, Lyon, France
| | - Laura Krisa
- Department of Physical Therapy, Thomas Jefferson University, Philadelphia, PA, USA
| | - Choukri Mekkaoui
- Harvard Medical School, Boston, MA, USA; Department of Radiology, Massachusetts General Hospital, Boston, MA, USA; A.A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA
| | - Feroze B Mohamed
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|
14
|
Takayama Y, Sato K, Tanaka S, Murayama R, Goto N, Yoshimitsu K. Deep learning-based magnetic resonance imaging reconstruction for improving the image quality of reduced-field-of-view diffusion-weighted imaging of the pancreas. World J Radiol 2023; 15:338-349. [PMID: 38179202 PMCID: PMC10762521 DOI: 10.4329/wjr.v15.i12.338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Revised: 11/12/2023] [Accepted: 12/04/2023] [Indexed: 12/26/2023] Open
Abstract
BACKGROUND It has been reported that deep learning-based reconstruction (DLR) can reduce image noise and artifacts, thereby improving the signal-to-noise ratio and image sharpness. However, no previous studies have evaluated the efficacy of DLR in improving image quality in reduced-field-of-view (reduced-FOV) diffusion-weighted imaging (DWI) [field-of-view optimized and constrained undistorted single-shot (FOCUS)] of the pancreas. We hypothesized that a combination of these techniques would improve DWI image quality without prolonging the scan time but would influence the apparent diffusion coefficient calculation. AIM To evaluate the efficacy of DLR for image quality improvement of FOCUS of the pancreas. METHODS This was a retrospective study evaluated 37 patients with pancreatic cystic lesions who underwent magnetic resonance imaging between August 2021 and October 2021. We evaluated three types of FOCUS examinations: FOCUS with DLR (FOCUS-DLR+), FOCUS without DLR (FOCUS-DLR-), and conventional FOCUS (FOCUS-conv). The three types of FOCUS and their apparent diffusion coefficient (ADC) maps were compared qualitatively and quantitatively. RESULTS FOCUS-DLR+ (3.62, average score of two radiologists) showed significantly better qualitative scores for image noise than FOCUS-DLR- (2.62) and FOCUS-conv (2.88) (P < 0.05). Furthermore, FOCUS-DLR+ showed the highest contrast ratio (CR) between the pancreatic parenchyma and adjacent fat tissue for b-values of 0 and 600 s/mm2 (0.72 ± 0.08 and 0.68 ± 0.08) and FOCUS-DLR- showed the highest CR between cystic lesions and the pancreatic parenchyma for the b-values of 0 and 600 s/mm2 (0.62 ± 0.21 and 0.62 ± 0.21) (P < 0.05), respectively. FOCUS-DLR+ provided significantly higher ADCs of the pancreas and lesion (1.44 ± 0.24 and 3.00 ± 0.66) compared to FOCUS-DLR- (1.39 ± 0.22 and 2.86 ± 0.61) and significantly lower ADCs compared to FOCUS-conv (1.84 ± 0.45 and 3.32 ± 0.70) (P < 0.05), respectively. CONCLUSION This study evaluated the efficacy of DLR for image quality improvement in reduced-FOV DWI of the pancreas. DLR can significantly denoise images without prolonging the scan time or decreasing the spatial resolution. The denoising level of DWI can be controlled to make the images appear more natural to the human eye. However, this study revealed that DLR did not ameliorate pancreatic distortion. Additionally, physicians should pay attention to the interpretation of ADCs after DLR application because ADCs are significantly changed by DLR.
Collapse
Affiliation(s)
- Yukihisa Takayama
- Department of Radiology, Faculty of Medicine, Fukuoka University, Fukuoka 8140180, Japan
| | - Keisuke Sato
- Department of Radiology, Faculty of Medicine, Fukuoka University, Fukuoka 8140180, Japan
| | - Shinji Tanaka
- Department of Radiology, Faculty of Medicine, Fukuoka University, Fukuoka 8140180, Japan
| | - Ryo Murayama
- Department of Radiology, Faculty of Medicine, Fukuoka University, Fukuoka 8140180, Japan
| | - Nahoko Goto
- Department of Radiology, Faculty of Medicine, Fukuoka University, Fukuoka 8140180, Japan
| | - Kengo Yoshimitsu
- Department of Radiology, Faculty of Medicine, Fukuoka University, Fukuoka 8140180, Japan
| |
Collapse
|
15
|
Zhang M, Arango N, Arefeen Y, Guryev G, Stockmann JP, White J, Adalsteinsson E. Stochastic-offset-enhanced restricted slice excitation and 180° refocusing designs with spatially non-linear ΔB 0 shim array fields. Magn Reson Med 2023; 90:2572-2591. [PMID: 37667645 PMCID: PMC10699120 DOI: 10.1002/mrm.29827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 06/30/2023] [Accepted: 07/26/2023] [Indexed: 09/06/2023]
Abstract
PURPOSE Developing a general framework with a novel stochastic offset strategy for the design of optimized RF pulses and time-varying spatially non-linear ΔB0 shim array fields for restricted slice excitation and refocusing with refined magnetization profiles within the intervals of the fixed voxels. METHODS Our framework uses the decomposition property of the Bloch equations to enable joint design of RF-pulses and shim array fields for restricted slice excitation and refocusing with auto-differentiation optimization. Bloch simulations are performed independently on orthogonal basis vectors, Mx, My, and Mz, which enables designs for arbitrary initial magnetizations. Requirements for refocusing pulse designs are derived from the extended phase graph formalism obviating time-consuming sub-voxel isochromatic simulations to model the effects of crusher gradients. To refine resultant slice-profiles because of voxelwise optimization functions, we propose an algorithm that stochastically offsets spatial points at which loss is computed during optimization. RESULTS We first applied our proposed design framework to standard slice-selective excitation and refocusing pulses in the absence of non-linear ΔB0 shim array fields and compared them against pulses designed with Shinnar-Le Roux algorithm. Next, we demonstrated our technique in a simulated setup of fetal brain imaging in pregnancy for restricted-slice excitation and refocusing of the fetal brain. CONCLUSIONS Our proposed framework for optimizing RF pulse and time-varying spatially non-linear ΔB0 shim array fields achieve high fidelity restricted-slice excitation and refocusing for fetal MRI, which could enable zoomed fast-spin-echo-MRI and other applications.
Collapse
Affiliation(s)
- Molin Zhang
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Nicolas Arango
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Yamin Arefeen
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Georgy Guryev
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Jason P. Stockmann
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Charlestown, MA, USA
| | - Jacob White
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Elfar Adalsteinsson
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| |
Collapse
|
16
|
Yoon D, Lutz AM. Diffusion Tensor Imaging of Peripheral Nerves: Current Status and New Developments. Semin Musculoskelet Radiol 2023; 27:641-648. [PMID: 37935210 DOI: 10.1055/s-0043-1775742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
Diffusion tensor imaging (DTI) is an emerging technique for peripheral nerve imaging that can provide information about the microstructural organization and connectivity of these nerves and complement the information gained from anatomical magnetic resonance imaging (MRI) sequences. With DTI it is possible to reconstruct nerve pathways and visualize the three-dimensional trajectory of nerve fibers, as in nerve tractography. More importantly, DTI allows for quantitative evaluation of peripheral nerves by the calculation of several important parameters that offer insight into the functional status of a nerve. Thus DTI has a high potential to add value to the work-up of peripheral nerve pathologies, although it is more technically demanding. Peripheral nerves pose specific challenges to DTI due to their small diameter and DTI's spatial resolution, contrast, location, and inherent field inhomogeneities when imaging certain anatomical locations. Numerous efforts are underway to resolve these technical challenges and thus enable wider acceptance of DTI in peripheral nerve MRI.
Collapse
Affiliation(s)
- Daehyun Yoon
- Department of Radiology and Biomedical Imaging, School of Medicine, University of California at San Francisco, San Francisco, California
| | - Amelie M Lutz
- Department of Radiology, Kantonal Hospital Thurgau, Muensterlingen, Switzerland
| |
Collapse
|
17
|
Jacobsen MC, Rigaud B, Simiele SJ, Rauch GM, Ning MS, Vedam S, Klopp AH, Stafford RJ, Brock KK, Venkatesan AM. Feasibility of quantitative diffusion-weighted imaging during intra-procedural MRI-guided brachytherapy of locally advanced cervical and vaginal cancers. Brachytherapy 2023; 22:736-745. [PMID: 37612174 DOI: 10.1016/j.brachy.2023.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 05/30/2023] [Accepted: 06/15/2023] [Indexed: 08/25/2023]
Abstract
PURPOSE To determine the feasibility of quantitative apparent diffusion coefficient (ADC) acquisition during magnetic resonance imaging-guided brachytherapy (MRgBT) using reduced field-of-view (rFOV) diffusion-weighted imaging (DWI). METHODS AND MATERIALS T2-weighted (T2w) MR and full-FOV single-shot echo planar (ssEPI) DWI were acquired in 7 patients with cervical or vaginal malignancy at baseline and prior to brachytherapy, while rFOV-DWI was acquired during MRgBT following brachytherapy applicator placement. The gross target volume (GTV) was contoured on the T2w images and registered to the ADC map. Voxels at the GTV's maximum Maurer distance comprised a central sub-volume (GTVcenter). Contour ADC mean and standard deviation were compared between timepoints using repeated measures ANOVA. RESULTS ssEPI-DWI mean ADC increased between baseline and prebrachytherapy from 1.03 ± 0.18 10-3 mm2/s to 1.34 ± 0.28 10-3 mm2/s for the GTV (p = 0.06) and from 0.84 ± 0.13 10-3 mm2/s to 1.26 ± 0.25 10-3 mm2/s at the level of the GTVcenter (p = 0.03), consistent with early treatment response. rFOV-DWI during MRgBT demonstrated mean ADC values of 1.28 ± 0.14 10-3 mm2/s and 1.28 ± 0.19 10-3 mm2/s for the GTV and GTVcenter, respectively (p = 0.02 and p = 0.03 relative to baseline). No significant differences were observed between ssEPI-DWI and rFOV-DWI ADC measurements. CONCLUSIONS Quantitative ADC measurement in the setting of MRI guided brachytherapy implant placement for cervical and vaginal cancers is feasible using rFOV-DWI, with comparable mean ADC comparable to prebrachytherapy ssEPI-DWI, and may enable MRI-guided radiotherapy targeting of low ADC, radiation resistant sub-volumes of tumor.
Collapse
Affiliation(s)
- Megan C Jacobsen
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX.
| | - Bastien Rigaud
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Samantha J Simiele
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Gaiane M Rauch
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Matthew S Ning
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Sastry Vedam
- University of Maryland, Department of Radiation Oncology, Baltimore, MD
| | - Ann H Klopp
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - R Jason Stafford
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Kristy K Brock
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Aradhana M Venkatesan
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX.
| |
Collapse
|
18
|
He Y, Wang M, Yi S, Lu Y, Ren J, Zhou P, Xu K. Diffusion-weighted imaging in the assessment of cervical cancer: comparison of reduced field-of-view diffusion-weighted imaging and conventional techniques. Acta Radiol 2023; 64:2485-2491. [PMID: 37545177 DOI: 10.1177/02841851231183870] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
BACKGROUND Cervical cancer (CC) is the second most common cancer in women worldwide. Diffusion-weighted imaging (DWI) plays an important role in the diagnosis of CC, but the conventional techniques are affected by many factors. PURPOSE To compare reduced-field-of-view (r-FOV) and full-field-of-view (f-FOV) DWI in the diagnosis of CC. MATERIAL AND METHODS Preoperative magnetic resonance imaging (MRI) with r-FOV and f-FOV DWI images were collected. Two radiologists reviewed the images using a subjective 4-point scale for anatomical features, magnetic susceptibility artifacts, visual distortion, and overall diagnostic confidence for r-FOV and f-FOV DWI. The objective features included the region of interest (ROI) signal intensity of the cervical lesion (SIlesion) and gluteus maximus muscle (SIgluteus), standard deviation of the background noise (SDbackground), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The differences of measured apparent diffusion coefficient (ADC) values between the two examinations in pathological grades and FIGO tumor stages were compared. RESULTS A total of 200 patients were included (170 with squamous cell carcinoma and 30 with adenocarcinoma). The scores of anatomical features, magnetic susceptibility artifacts, visual distortion, and overall diagnostic confidence for r-FOV DWI were significantly higher than those for f-FOV DWI. There was no difference in SNR and CNR between r-FOV DWI and f-FOV DWI. There were significant differences in ADC values between the two groups in all comparisons (P < 0.05). CONCLUSION Compared with f-FOV DWI, r-FOV DWI might provide clearer imaging, fewer artifacts, less distortion, and higher image quality for the diagnosis of CC and might assist in the detection of CC.
Collapse
Affiliation(s)
- Yakun He
- Department of radiology, Sichuan Cancer Hospital, Chengdu, PR China
| | - Min Wang
- Department of radiology, Sichuan Cancer Hospital, Chengdu, PR China
| | - Siqi Yi
- Department of radiology, Sichuan Cancer Hospital, Chengdu, PR China
| | - Yujie Lu
- Department of radiology, Sichuan Cancer Hospital, Chengdu, PR China
| | - Jing Ren
- Department of radiology, Sichuan Cancer Hospital, Chengdu, PR China
| | - Peng Zhou
- Department of radiology, Sichuan Cancer Hospital, Chengdu, PR China
| | - Ke Xu
- Department of Otolaryngology-Head & Neck Surgery, West China Hospital, Sichuan University, Chengdu, PR China
| |
Collapse
|
19
|
Yildiz S, Schecht M, Aggarwal A, Nael K, Doshi A, Pawha PS. Diffusion Weighted Imaging in Spine Tumors. Neuroimaging Clin N Am 2023; 33:459-475. [PMID: 37356862 DOI: 10.1016/j.nic.2023.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/27/2023]
Abstract
Diffusion weighted imaging (DWI) has developed into a powerful tool for the evaluation of spine tumors, particularly for the assessment of vertebral marrow lesions and intramedullary tumors. Advances in magnetic resonance techniques have improved the quality of spine DWI and diffusion tensor imaging (DTI) in recent years, with increased reproducibility and utilization. DTI, with quantitative parameters such as fractional anisotropy and qualitative visual assessment of nerve fiber tracts, can play a valuable role in the evaluation and surgical planning of spinal cord tumors. These widely available techniques can be used to enhance the diagnostic evaluation of spinal tumors.
Collapse
Affiliation(s)
- Sema Yildiz
- Division of Neuroradiology, Department of Radiology, Icahn School of Medicine at Mount Sinai Hospital, 1468 Madison Avenue MC Level, New York, NY 10029, USA.
| | - Michael Schecht
- Division of Neuroradiology, Department of Radiology, Icahn School of Medicine at Mount Sinai Hospital, 1468 Madison Avenue MC Level, New York, NY 10029, USA
| | - Amit Aggarwal
- Division of Neuroradiology, Department of Radiology, Icahn School of Medicine at Mount Sinai Hospital, 1468 Madison Avenue MC Level, New York, NY 10029, USA
| | - Kambiz Nael
- Division of Neuroradiology, Department of Radiology, Ronald Reagan UCLA Medical Center, 757 Westwood Plaza, Los Angeles, CA 90095, USA
| | - Amish Doshi
- Division of Neuroradiology, Department of Radiology, Icahn School of Medicine at Mount Sinai Hospital, 1468 Madison Avenue MC Level, New York, NY 10029, USA
| | - Puneet S Pawha
- Division of Neuroradiology, Department of Radiology, Icahn School of Medicine at Mount Sinai Hospital, 1468 Madison Avenue MC Level, New York, NY 10029, USA
| |
Collapse
|
20
|
Baron P, Wielema M, Dijkstra H, Potze JH, Dorrius MD, Sijens PE. Comparison of conventional and higher-resolution reduced-FOV diffusion-weighted imaging of breast tissue. MAGMA (NEW YORK, N.Y.) 2023; 36:613-619. [PMID: 36527516 DOI: 10.1007/s10334-022-01055-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 11/11/2022] [Accepted: 12/07/2022] [Indexed: 06/17/2023]
Abstract
OBJECTIVE Reduced FOV-diffusion-weighted imaging (rFOV-DWI) allows for acquisition of a tissue region without back-folding, and may have better fat suppression than conventional DWI imaging (c-DWI). The aim was to compare the ADCs obtained with c-DWI bilateral-breast imaging with single-breast rFOV-DWI. MATERIALS AND METHODS Breasts of 38 patients were scanned at 3 T. The mean ADC values obtained for 38 lesions, and fibro-glandular (N = 35) and adipose (N = 38) tissue ROIs were compared between c-DWI and higher-resolution rFOV-DWI (Wilcoxon rank test). Also, the ADCs were compared between the two acquisitions for an oil-only phantom and a combined water/oil phantom. Furthermore, ghost artifacts were assessed. RESULTS No significant difference in mean ADC was found between the acquisitions for lesions (c-DWI: 1.08 × 10-3 mm2/s, rFOV-DWI: 1.13 × 10-3 mm2/s) and fibro-glandular tissue. For adipose tissue, the ADC using rFOV-DWI (0.31 × 10-3 mm2/s) was significantly higher than c-DWI (0.16 × 10-3 mm2/s). For the oil-only phantom, no difference in ADC was found. However, for the water/oil phantom, the ADC of oil was significantly higher with rFOV-DWI compared to c-DWI. DISCUSSION Although ghost artifacts were observed for both acquisitions, they appeared to have a greater impact for rFOV-DWI. However, no differences in mean lesions' ADC values were found, and therefore this study suggests that rFOV can be used diagnostically for single-breast DWI imaging.
Collapse
Affiliation(s)
- Paul Baron
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.
| | - Mirjam Wielema
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - Hildebrand Dijkstra
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - Jan Hendrik Potze
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - Monique D Dorrius
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - Paul E Sijens
- Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| |
Collapse
|
21
|
Ota T, Tsuboyama T, Onishi H, Nakamoto A, Fukui H, Yano K, Honda T, Kiso K, Tatsumi M, Tomiyama N. Diagnostic accuracy of MRI for evaluating myometrial invasion in endometrial cancer: a comparison of MUSE-DWI, rFOV-DWI, and DCE-MRI. LA RADIOLOGIA MEDICA 2023:10.1007/s11547-023-01635-4. [PMID: 37120661 DOI: 10.1007/s11547-023-01635-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 04/20/2023] [Indexed: 05/01/2023]
Abstract
OBJECTIVES To compare the image quality of high-resolution diffusion-weighted imaging (DWI) using multiplexed sensitivity encoding (MUSE) versus reduced field-of-view (rFOV) techniques in endometrial cancer (EC) and to compare the diagnostic performance of these techniques with that of dynamic contrast-enhanced (DCE) MRI for assessing myometrial invasion of EC. METHODS MUSE-DWI and rFOV-DWI were obtained preoperatively in 58 women with EC. Three radiologists assessed the image quality of MUSE-DWI and rFOV-DWI. For 55 women who underwent DCE-MRI, the same radiologists assessed the superficial and deep myometrial invasion using MUSE-DWI, rFOV-DWI, and DCE-MRI. Qualitative scores were compared using the Wilcoxon signed-rank test. Receiver operating characteristic analysis was performed to compare the diagnostic performance. RESULTS Artifacts, sharpness, lesion conspicuity, and overall quality were significantly better with MUSE-DWI than with rFOV-DWI (p < 0.05). The area under the curve (AUC) of MUSE-DWI, rFOV-DWI, and DCE-MRI for the assessment of myometrial invasion were not significantly different except for significantly higher AUC of MUSE-DWI than that of DCE-MRI for superficial myometrial invasion (0.76 for MUSE-DWI and 0.64 for DCE-MRI, p = 0.049) and for deep myometrial invasion (0.92 for MUSE-DWI and 0.80 for DCE-MRI, p = 0.022) in one observer, and that of rFOV-DWI for deep myometrial invasion in another observer (0.96 for MUSE-DWI and 0.89 for rFOV-MRI, p = 0.048). CONCLUSION MUSE-DWI exhibits better image quality than rFOV-DWI. MUSE-DWI and rFOV-DWI shows almost equivalent diagnostic performance compared to DCE-MRI for assessing superficial and deep myometrial invasion in EC although MUSE-DWI may be helpful for some radiologists.
Collapse
Affiliation(s)
- Takashi Ota
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Takahiro Tsuboyama
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Hiromitsu Onishi
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Atsushi Nakamoto
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Hideyuki Fukui
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Keigo Yano
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Toru Honda
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kengo Kiso
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Mitsuaki Tatsumi
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Noriyuki Tomiyama
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, D1, 2-2, Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
22
|
Sun K, Dan G, Zhong Z, Zhou XJ. Multi-readout DWI with a reduced FOV for studying the coupling between diffusion and T 2 * relaxation in the prostate. Magn Reson Med 2023; 90:250-258. [PMID: 36932652 DOI: 10.1002/mrm.29636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 02/16/2023] [Accepted: 02/23/2023] [Indexed: 03/19/2023]
Abstract
PURPOSE To develop a DWI sequence with multiple readout echo-trains in a single shot (multi-readout DWI) over a reduced FOV, and to demonstrate its ability to achieve high data acquisition efficiency in the study of coupling between diffusion and relaxation in the human prostate. METHODS The proposed multi-readout DWI sequence plays out multiple EPI readout echo-trains after a Stejskal-Tanner diffusion preparation module. Each EPI readout echo-train corresponded to a distinct effective TE. To maintain a high spatial resolution with a relatively short echo-train for each readout, a 2D RF pulse was used to limit the FOV. Experiments were performed on the prostate of six healthy subjects to acquire a set of images with three b values (0, 500, and 1000 s/mm2 ) and three TEs (63.0, 78.8, and 94.6 ms), producing three ADC maps at different TEs and three T 2 * $$ {T}_2^{\ast } $$ maps at different b values. RESULTS Multi-readout DWI enabled a threefold acceleration without compromising the spatial resolution when compared with a conventional single-readout sequence. Images with three b values and three TEs were obtained in 3 min 40 s with an adequate SNR (≥ 26.9). The ADC values (1.45 ± 0.13, 1.52 ± 0.14, and 1.58 ± 0.15 μm 2 / ms $$ {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ; P < 0.01) exhibited an increasing trend as TEs increased (63.0 ms, 78.8 ms, and 94.6 ms), whereas T 2 * $$ {T}_2^{\ast } $$ values (74.78 ± 13.21, 63.21 ± 7.84, and 56.61 ± 5.05 ms; P < 0.01) decreases as the b values increased (0, 500, and 1000 s/mm2 ). CONCLUSION The multi-readout DWI sequence over a reduced FOV provides a time-efficient technique to study the coupling between diffusion and relaxation times.
Collapse
Affiliation(s)
- Kaibao Sun
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Guangyu Dan
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Zheng Zhong
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Xiaohong Joe Zhou
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA.,Departments of Radiology and Neurosurgery, University of Illinois College of Medicine at Chicago, Chicago, Illinois, USA
| |
Collapse
|
23
|
Meng T, Liu H, Liu J, Wang F, Xie C, Ke L, He H. The investigation of reduced field-of-view diffusion-weighted imaging (DWI) in patients with nasopharyngeal carcinoma: comparison with conventional DWI. Acta Radiol 2023; 64:2118-2125. [PMID: 36912041 DOI: 10.1177/02841851231159389] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2023]
Abstract
BACKGROUND Field-of-view optimized and constrained undistorted single-shot imaging (FOCUS) is a new sequence that shows enhanced anatomical details, improving the diffusion-weighted (DW) images. PURPOSE To investigate the value of FOCUS diffusion-weighted imaging (DWI) in the evaluation of nasopharyngeal carcinoma (NPC) and compare it with the single-shot echo planner imaging (SS-EPI) DWI approach. MATERIAL AND METHODS A total of 87 patients with NPC underwent magnetic resonance imaging, including FOCUS and SS-EPI DWI sequences. The signal-to-noise ratio (SNR), signal-intensity ratio (SIR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values of the nasopharyngeal lesions were measured and compared. According to the clinical stages of patients, T and N were divided into early and advanced stage groups, respectively. The mean ADC values of the two techniques were computed, and the area under the curve (AUC) was estimated to calculate the diagnostic efficiency. RESULTS Subjective and objective image qualitative values of FOCUS were significantly higher than those of SS-EPI. The ADC values for FOCUS of early T and N stages were significantly lower than those of the advanced stages. CONCLUSION FOCUS provides significantly better image quality in NPC compared to SS-EPI, with lower ADC values for early-stage disease than late-stage disease.
Collapse
Affiliation(s)
- Tiebao Meng
- Department of Radiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, 71067Sun Yat-sen University Cancer Center, Guangzhou, PR China
| | - Huiming Liu
- Department of Radiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, 71067Sun Yat-sen University Cancer Center, Guangzhou, PR China
| | - Jinbo Liu
- Department of Radiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, 71067Sun Yat-sen University Cancer Center, Guangzhou, PR China
| | - Feixiang Wang
- Department of Thoracic Oncology, Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou, PR China
| | - Chuanmiao Xie
- Department of Radiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, 71067Sun Yat-sen University Cancer Center, Guangzhou, PR China
| | - Liangru Ke
- Department of Radiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, 71067Sun Yat-sen University Cancer Center, Guangzhou, PR China
| | - Haoqiang He
- Department of Radiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, 71067Sun Yat-sen University Cancer Center, Guangzhou, PR China
| |
Collapse
|
24
|
Yang T, Li Y, Ye Z, Yao S, Li Q, Yuan Y, Song B. Diffusion Weighted Imaging of the Abdomen and Pelvis: Recent Technical Advances and Clinical Applications. Acad Radiol 2023; 30:470-482. [PMID: 36038417 DOI: 10.1016/j.acra.2022.07.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/20/2022] [Accepted: 07/23/2022] [Indexed: 01/25/2023]
Abstract
Diffusion weighted imaging (DWI) serves as one of the most important functional magnetic resonance imaging techniques in abdominal and pelvic imaging. It is designed to reflect the diffusion of water molecules and is particularly sensitive to the malignancies. Yet, the limitations of image distortion and artifacts in single-shot DWI may hamper its widespread use in clinical practice. With recent technical advances in DWI, such as simultaneous multi-slice excitation, computed or reduced field-of-view techniques, as well as advanced shimming methods, it is possible to achieve shorter acquisition time, better image quality, and higher robustness in abdominopelvic DWI. This review discussed the recent advances of each DWI approach, and highlighted its future perspectives in abdominal and pelvic imaging, hoping to familiarize physicians and radiologists with the technical improvements in this field and provide future research directions.
Collapse
Affiliation(s)
- Ting Yang
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Ying Li
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Zheng Ye
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Shan Yao
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Qing Li
- MR Collaborations, Siemens Healthcare, Shanghai, China
| | - Yuan Yuan
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China; Department of Radiology, Sanya People's Hospital, Sanya, Hainan, China.
| |
Collapse
|
25
|
Sun K, Zhong Z, Dan G, Wang K, Karaman MM, Luo Q, Zhou XJ. Simultaneous multi-segment (SMSeg) EPI over multiple focal regions. Phys Med Biol 2023; 68:10.1088/1361-6560/acb2a9. [PMID: 36634366 PMCID: PMC9994176 DOI: 10.1088/1361-6560/acb2a9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 01/12/2023] [Indexed: 01/14/2023]
Abstract
Objective.This study aimed at developing a simultaneous multi-segment (SMSeg) imaging technique using a two-dimensional (2D) RF pulse in conjunction with echo planar imaging (EPI) to image multiple focal regions.Approach.The SMSeg technique leveraged periodic replicates of the excitation profile of a 2D RF pulse to simultaneously excite multiple focal regions at different locations. These locations were controlled by rotating and scaling transmit k-space trajectories. The resulting multiple isolated focal regions were projected into a composite 'slice' for display. GRAPPA-based parallel imaging was incorporated into SMSeg by taking advantage of coil sensitivity variations in both the phase-encoded and slice-selection directions. The SMSeg technique was implemented at 3 T in a single-shot gradient-echo EPI sequence and demonstrated in a phantom and human brains for both anatomic imaging and functional imaging.Main results.In both the phantom and the human brain, SMSeg images from three focal regions were simultaneously acquired. SMSeg imaging enabled up to a six-fold acceleration in parallel imaging without causing appreciable residual aliasing artifacts when compared with a conventional gradient-echo EPI sequence with the same acceleration factor. In the functional imaging experiment, BOLD activations associated with a visuomotor task were simultaneously detected in two non-coplanar segments (each with a size of 240 × 30 mm2), corresponding to visual and motor cortices, respectively.Significance.Our study has demonstrated that SMSeg imaging can be a viable method for studying multiple focal regions simultaneously.
Collapse
Affiliation(s)
- Kaibao Sun
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Zheng Zhong
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Guangyu Dan
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Kezhou Wang
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America.,VasSol, Inc., River Forest, IL, United States of America
| | - M Muge Karaman
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Qingfei Luo
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America
| | - Xiaohong Joe Zhou
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, United States of America.,Departments of Radiology and Neurosurgery, University of Illinois College of Medicine at Chicago, Chicago, IL, United States of America
| |
Collapse
|
26
|
El Homsi M, Bates DDB, Mazaheri Y, Sosa R, Gangai N, Petkovska I. Multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE) in diffusion-weighted imaging for rectal MRI: a quantitative and qualitative analysis at multiple b-values. Abdom Radiol (NY) 2023; 48:448-457. [PMID: 36307596 PMCID: PMC9905276 DOI: 10.1007/s00261-022-03710-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/07/2022] [Accepted: 10/10/2022] [Indexed: 01/19/2023]
Abstract
PURPOSE To compare four diffusion-weighted imaging (DWI) sequences for image quality, rectal contour, and lesion conspicuity, and to assess the difference in their signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC). METHODS In this retrospective study of 36 consecutive patients who underwent 3.0 T rectal MRI from January-June 2020, DWI was performed with single-shot echo planar imaging (ss-EPI) (b800 s/mm2), multiplexed sensitivity encoding (MUSE) (b800 s/mm2), MUSE (b1500 s/mm2), and field-of-view optimized and constrained undistorted single-shot (FOCUS) (b1500 s/mm2). Two radiologists independently scored image quality using a 5-point Likert scale. Inter-reader agreement was assessed using the weighted Cohen's к. SNR, CNR, and ADC measurements were compared using the paired t-test. RESULTS For both readers, MUSE b800 scored significantly higher for image quality, rectal contour, and lesion conspicuity compared to ss-EPI; MUSE b800 also scored significantly higher for image quality and rectal contour compared to all other sequences. Lesion conspicuity was equally superior for MUSE b800 and MUSE b1500 compared to the other two sequences. There was good to excellent inter-reader agreement for all qualitative features (к = 0.72-0.88). MUSE b800 had the highest SNR; MUSE b1500 had the highest CNR. A significant difference in ADC was observed between ss-EPI compared to the other sequences (p < 0.001) and between MUSE b800 and FOCUS. No significant difference in ADC was found between MUSE b1500 and FOCUS b1500. CONCLUSION MUSE b800 improved image quality over ss-EPI and both MUSE b800 and b1500 showed better tumor conspicuity compared to conventional ss-EPI.
Collapse
Affiliation(s)
- Maria El Homsi
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - David D B Bates
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Yousef Mazaheri
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Ramon Sosa
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Natalie Gangai
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Iva Petkovska
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
| |
Collapse
|
27
|
Tang Q, Zhou Q, Chen W, Sang L, Xing Y, Liu C, Wang K, Liu WV, Xu L. A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors. Insights Imaging 2023; 14:12. [PMID: 36645541 PMCID: PMC9842823 DOI: 10.1186/s13244-022-01350-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Accepted: 12/05/2022] [Indexed: 01/17/2023] Open
Abstract
OBJECTIVES This study aimed to evaluate the feasibility of reduced full-of-view synthetic high-b value diffusion-weighted images (rFOV-syDWIs) in the clinical application of cervical cancer based on image quality and diagnostic efficacy. METHODS We retrospectively evaluated the data of 35 patients with cervical cancer and 35 healthy volunteers from May to November 2021. All patients and volunteers underwent rFOV-DWI scans, including a 13b-protocol: b = 0, 25, 50, 75, 100, 150, 200, 400, 600, 800, 1000, 1200, and 1500 s/mm2 and a 5b-protocol: b = 0, 100, 400, 800,1500 s/mm2. rFOV-syDWIs with b values of 1200 (rFOV-syDWIb=1200) and 1500 (rFOV-syDWIb=1500) were generated from two different multiple-b-value image datasets using a mono-exponential fitting algorithm. According to homoscedasticity and normality assessed by the Levene's test and Shapiro-Wilk test, the inter-modality differences of quantitative measurements were, respectively, examined by Wilcoxon signed-rank test or paired t test and the inter-group differences of ADC values were examined by independent t test or Mann-Whitney U test. RESULTS A higher inter-reader agreement between SNRs and CNRs was found in 13b-protocol and 5b-protocol rFOV-syDWIb=1200/1500 compared to 13b-protocol rFOV-sDWIb=1200/1500 (p < 0.05). AUC of 5b-protocol syADCmean,b=1200/1500 and syADCminimum,b=1200/1500 was equal or higher than that of 13b-protocol sADCmean,b=1200/1500 and sADCminimum,b=1200/1500. CONCLUSIONS rFOV-syDWIs provide better lesion clarity and higher image quality than rFOV-sDWIs. 5b-protocol rFOV-syDWIs shorten scan time, and synthetic ADCs offer reliable diagnosis value as scanned 13b-protocol DWIs.
Collapse
Affiliation(s)
- Qian Tang
- grid.443573.20000 0004 1799 2448Department of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China ,grid.443573.20000 0004 1799 2448Biomedical Engineering College, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China
| | - Qiqi Zhou
- grid.443573.20000 0004 1799 2448Department of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China
| | - Wen Chen
- grid.443573.20000 0004 1799 2448Department of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China
| | - Ling Sang
- grid.443573.20000 0004 1799 2448Department of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China
| | - Yu Xing
- grid.443573.20000 0004 1799 2448Department of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China
| | - Chao Liu
- grid.443573.20000 0004 1799 2448Department of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China
| | - Kejun Wang
- grid.443573.20000 0004 1799 2448Department of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China
| | | | - Lin Xu
- grid.443573.20000 0004 1799 2448Department of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei China
| |
Collapse
|
28
|
Zheng L, Yang C, Liang L, Rao S, Dai Y, Zeng M. T2-weighted MRI and reduced-FOV diffusion-weighted imaging of the human pancreas at 5 T: A comparison study with 3 T. Med Phys 2023; 50:344-353. [PMID: 36107133 DOI: 10.1002/mp.15970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 08/29/2022] [Accepted: 08/29/2022] [Indexed: 01/25/2023] Open
Abstract
PURPOSE The purpose of this study was to explore the feasibility of pancreatic imaging at 5 T and evaluate the practical improvement of T2-weighted MRI and diffusion-weighted imaging (DWI) at 5 T as compared with 3 T. METHODS Eighteen healthy subjects were recruited for this pilot study. MRI examinations were performed using 3 and 5 T scanners. MRI sequences included T2-weighted fast spin-echo and DWI with reduced field-of-view. Subjective image analysis using a four-point Likert scale was performed by two experienced radiologists. The SNR, contrast ratio, and apparent diffusion coefficient (ADC) were measured in the pancreatic head, body, and tail. The coefficient of variation (CV) of the ADC was calculated. A series of paired Wilcoxon tests were used to compare the subjective image quality, mean ADC value, and CV of ADC between the 3 and 5 T measurements. p <0.05 was considered statistically significant. RESULTS For T2-weighted images, there were no significant differences in image quality ratings between 3 and 5 T. On DWI images (b = 0 and 800 s/mm2 ), the image quality ratings were significantly higher at 5 T than at 3 T. The SNRs of both T2-weighted and DWI images were significantly higher at 5 T. There was no significant difference in the mean ADC values and CV of ADC between 3 and 5 T. CONCLUSION This initial study proved that 5 T MRI can be used to acquire pancreatic images with higher SNR and sufficient image quality compared to 3 T MRI.
Collapse
Affiliation(s)
- Liyun Zheng
- Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.,Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China
| | - Chun Yang
- Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Liang Liang
- Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Shengxiang Rao
- Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yongming Dai
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Mengsu Zeng
- Shanghai Institute of Medical Imaging, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
29
|
Musall BC, Adrada BE, Candelaria RP, Mohamed RMM, Abdelhafez AH, Son JB, Sun J, Santiago L, Whitman GJ, Moseley TW, Scoggins ME, Mahmoud HS, White JB, Hwang KP, Elshafeey NA, Boge M, Zhang S, Litton JK, Valero V, Tripathy D, Thompson AM, Yam C, Wei P, Moulder SL, Pagel MD, Yang WT, Ma J, Rauch GM. Quantitative Apparent Diffusion Coefficients From Peritumoral Regions as Early Predictors of Response to Neoadjuvant Systemic Therapy in Triple-Negative Breast Cancer. J Magn Reson Imaging 2022; 56:1901-1909. [PMID: 35499264 PMCID: PMC9626398 DOI: 10.1002/jmri.28219] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 04/20/2022] [Accepted: 04/21/2022] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Pathologic complete response (pCR) to neoadjuvant systemic therapy (NAST) in triple-negative breast cancer (TNBC) is a strong predictor of patient survival. Edema in the peritumoral region (PTR) has been reported to be a negative prognostic factor in TNBC. PURPOSE To determine whether quantitative apparent diffusion coefficient (ADC) features from PTRs on reduced field-of-view (rFOV) diffusion-weighted imaging (DWI) predict the response to NAST in TNBC. STUDY TYPE Prospective. POPULATION/SUBJECTS A total of 108 patients with biopsy-proven TNBC who underwent NAST and definitive surgery during 2015-2020. FIELD STRENGTH/SEQUENCE A 3.0 T/rFOV single-shot diffusion-weighted echo-planar imaging sequence (DWI). ASSESSMENT Three scans were acquired longitudinally (pretreatment, after two cycles of NAST, and after four cycles of NAST). For each scan, 11 ADC histogram features (minimum, maximum, mean, median, standard deviation, kurtosis, skewness and 10th, 25th, 75th, and 90th percentiles) were extracted from tumors and from PTRs of 5 mm, 10 mm, 15 mm, and 20 mm in thickness with inclusion and exclusion of fat-dominant pixels. STATISTICAL TESTS ADC features were tested for prediction of pCR, both individually using Mann-Whitney U test and area under the receiver operating characteristic curve (AUC), and in combination in multivariable models with k-fold cross-validation. A P value < 0.05 was considered statistically significant. RESULTS Fifty-one patients (47%) had pCR. Maximum ADC from PTR, measured after two and four cycles of NAST, was significantly higher in pCR patients (2.8 ± 0.69 vs 3.5 ± 0.94 mm2 /sec). The top-performing feature for prediction of pCR was the maximum ADC from the 5-mm fat-inclusive PTR after cycle 4 of NAST (AUC: 0.74; 95% confidence interval: 0.64, 0.84). Multivariable models of ADC features performed similarly for fat-inclusive and fat-exclusive PTRs, with AUCs ranging from 0.68 to 0.72 for the cycle 2 and cycle 4 scans. DATA CONCLUSION Quantitative ADC features from PTRs may serve as early predictors of the response to NAST in TNBC. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 4.
Collapse
Affiliation(s)
- Benjamin C Musall
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Beatriz E Adrada
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Rosalind P Candelaria
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Rania M M Mohamed
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Abeer H Abdelhafez
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jong Bum Son
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jia Sun
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Lumarie Santiago
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Gary J Whitman
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Tanya W Moseley
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Marion E Scoggins
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Hagar S Mahmoud
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jason B White
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Ken-Pin Hwang
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Nabil A Elshafeey
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Medine Boge
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Shu Zhang
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jennifer K Litton
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Vicente Valero
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Debu Tripathy
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Alastair M Thompson
- Division of Surgical Oncology, Baylor College of Medicine, Houston, Texas, USA
| | - Clinton Yam
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Peng Wei
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Stacy L Moulder
- Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Mark D Pagel
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Wei T Yang
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jingfei Ma
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Gaiane M Rauch
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
30
|
Granger SJ, Colon-Perez L, Larson MS, Phelan M, Keator DB, Janecek JT, Sathishkumar MT, Smith AP, McMillan L, Greenia D, Corrada MM, Kawas CH, Yassa MA. Hippocampal dentate gyrus integrity revealed with ultrahigh resolution diffusion imaging predicts memory performance in older adults. Hippocampus 2022; 32:627-638. [PMID: 35838075 PMCID: PMC10510739 DOI: 10.1002/hipo.23456] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 05/26/2022] [Accepted: 06/30/2022] [Indexed: 11/08/2022]
Abstract
Medial temporal lobe (MTL) atrophy is a core feature of age-related cognitive decline and Alzheimer's disease (AD). While regional volumes and thickness are often used as a proxy for neurodegeneration, they lack the sensitivity to serve as an accurate diagnostic test and indicate advanced neurodegeneration. Here, we used a submillimeter resolution diffusion weighted MRI sequence (ZOOMit) to quantify microstructural properties of hippocampal subfields in older adults (63-98 years old) using tensor derived measures: fractional anisotropy (FA) and mean diffusivity (MD). We demonstrate that the high-resolution sequence, and not a standard resolution sequence, identifies dissociable profiles for CA1, dentate gyrus (DG), and the collateral sulcus. Using ZOOMit, we show that advanced age is associated with increased MD of the CA1 and DG as well as decreased FA of the DG. Increased MD of the DG, reflecting decreased cellular density, mediated the relationship between age and word list recall. Further, increased MD in the DG, but not DG volume, was linked to worse spatial pattern separation. Our results demonstrate that ultrahigh-resolution diffusion imaging enables the detection of microstructural differences in hippocampal subfield integrity and will lead to novel insights into the mechanisms of age-related memory loss.
Collapse
Affiliation(s)
- Steven J. Granger
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
| | - Luis Colon-Perez
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
| | - Myra Saraí Larson
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
| | - Michael Phelan
- UC Institute for Memory Impairments and Neurological Disorders, University of California, Irvine 92697
| | - David B. Keator
- Department of Psychiatry and Human Behavior, University of California, Irvine, CA 92697
| | - John T. Janecek
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
| | - Mithra T. Sathishkumar
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
| | - Anna P. Smith
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
| | - Liv McMillan
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
| | - Dana Greenia
- Department of Neurology, University of California, Irvine 92697
| | | | - Claudia H. Kawas
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
- Department of Neurology, University of California, Irvine 92697
| | - Michael A. Yassa
- Center for the Neurobiology of Learning and Memory, University of California, Irvine 92697
- Department of Neurobiology and Behavior, University of California, Irvine 92697
- Department of Psychiatry and Human Behavior, University of California, Irvine, CA 92697
- Department of Neurology, University of California, Irvine 92697
| |
Collapse
|
31
|
Barlas BA, Bahadir CD, Kafali SG, Yilmaz U, Saritas EU. Sheared two-dimensional radiofrequency excitation for off-resonance robustness and fat suppression in reduced field-of-view imaging. Magn Reson Med 2022; 88:2504-2519. [PMID: 36000548 DOI: 10.1002/mrm.29416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 07/16/2022] [Accepted: 07/27/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE Two-dimensional (2D) echo-planar radiofrequency (RF) pulses are widely used for reduced field-of-view (FOV) imaging in applications such as diffusion-weighted imaging. However, long pulse durations render the 2D RF pulses sensitive to off-resonance effects, causing local signal losses in reduced-FOV images. This work aims to achieve off-resonance robustness for 2D RF pulses via a sheared trajectory design. THEORY AND METHODS A sheared 2D RF pulse design is proposed to reduce pulse durations while covering identical excitation k-space extent as a standard 2D RF pulse. For a given shear angle, the number of sheared trajectory lines is minimized to obtain the shortest pulse duration, such that the excitation replicas are repositioned outside the slice stack to guarantee unlimited slice coverage. A target fat/water signal ratio of 5% is chosen to achieve robust fat suppression. RESULTS Simulations, imaging experiments on a custom head and neck phantom, and in vivo imaging experiments in the spinal cord at 3 T demonstrate that the sheared 2D RF design provides significant improvement in image quality while preserving profile sharpnesses. In regions with high off-resonance effects, the sheared 2D RF pulse improves the signal by more than 50% when compared to the standard 2D RF pulse. CONCLUSION The proposed sheared 2D RF design successfully reduces pulse durations, exhibiting significantly improved through-plane off-resonance robustness, while providing unlimited slice coverage and high fidelity fat suppression. This method will be especially beneficial in regions suffering from a variety of off-resonance effects, such as spinal cord and breast.
Collapse
Affiliation(s)
- Bahadir Alp Barlas
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Cagla Deniz Bahadir
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.,Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Sevgi Gokce Kafali
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.,Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA
| | - Ugur Yilmaz
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Emine Ulku Saritas
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.,Neuroscience Graduate Program, Bilkent University, Ankara, Turkey
| |
Collapse
|
32
|
Reduced field-of-view and multi-shot DWI acquisition techniques: Prospective evaluation of image quality and distortion reduction in prostate cancer imaging. Magn Reson Imaging 2022; 93:108-114. [DOI: 10.1016/j.mri.2022.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/03/2022] [Accepted: 08/03/2022] [Indexed: 11/20/2022]
|
33
|
Ueno Y, Tamada T, Sofue K, Murakami T. Diffusion and quantification of diffusion of prostate cancer. Br J Radiol 2022; 95:20210653. [PMID: 34538094 PMCID: PMC8978232 DOI: 10.1259/bjr.20210653] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
For assessing a cancer treatment, and for detecting and characterizing cancer, Diffusion-weighted imaging (DWI) is commonly used. The key in DWI's use extracranially has been due to the emergence of of high-gradient amplitude and multichannel coils, parallelimaging, and echo-planar imaging. The benefit has been fewer motion artefacts and high-quality prostate images.Recently, new techniques have been developed to improve the signal-to-noise ratio of DWI with fewer artefacts, allowing an increase in spatial resolution. For apparent diffusion coefficient quantification, non-Gaussian diffusion models have been proposed as additional tools for prostate cancer detection and evaluation of its aggressiveness. More recently, radiomics and machine learning for prostate magnetic resonance imaging have emerged as novel techniques for the non-invasive characterisation of prostate cancer. This review presents recent developments in prostate DWI and discusses its potential use in clinical practice.
Collapse
Affiliation(s)
- Yoshiko Ueno
- Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Tsutomu Tamada
- Departmentof Radiology, Kawasaki Medical School, Kurashiki, Japan
| | - Keitaro Sofue
- Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Takamichi Murakami
- Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
| |
Collapse
|
34
|
Towards reliable spinal cord fMRI: assessment of common imaging protocols. Neuroimage 2022; 250:118964. [DOI: 10.1016/j.neuroimage.2022.118964] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 01/07/2022] [Accepted: 02/01/2022] [Indexed: 01/29/2023] Open
|
35
|
High-Resolution, High b-Value Computed Diffusion-Weighted Imaging Improves Detection of Pancreatic Ductal Adenocarcinoma. Cancers (Basel) 2022; 14:cancers14030470. [PMID: 35158737 PMCID: PMC8833466 DOI: 10.3390/cancers14030470] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 01/13/2022] [Indexed: 02/04/2023] Open
Abstract
Background: Our purpose was to investigate the potential of high-resolution, high b-value computed DWI (cDWI) in pancreatic ductal adenocarcinoma (PDAC) detection. Materials and Methods: We retrospectively enrolled 44 patients with confirmed PDAC. Respiratory-triggered, diffusion-weighted, single-shot echo-planar imaging (ss-EPI) with both conventional (i.e., full field-of-view, 3 × 3 × 4 mm voxel size, b = 0, 50, 300, 600 s/mm2) and high-resolution (i.e., reduced field-of-view, 2.5 × 2.5 × 3 mm voxel size, b = 0, 50, 300, 600, 1000 s/mm2) imaging was performed for suspected PDAC. cDWI datasets at b = 1000 s/mm2 were generated for the conventional and high-resolution datasets. Three radiologists were asked to subjectively rate (on a Likert scale of 1–4) the following metrics: image quality, lesion detection and delineation, and lesion-to-pancreas intensity relation. Furthermore, the following quantitative image parameters were assessed: apparent signal-to-noise ratio (aSNR), contrast-to-noise ratio (aCNR), and lesion-to-pancreas contrast ratio (CR). Results: High-resolution, high b-value computed DWI (r-cDWI1000) enabled significant improvement in lesion detection and a higher incidence of a high lesion-to-pancreas intensity relation (type 1, clear hyperintense) compared to conventional high b-value computed and high-resolution high b-value acquired DWI (f-cDWI1000 and r-aDWI1000, respectively). Image quality was rated inferior in the r-cDWI1000 datasets compared to r-aDWI1000. Furthermore, the aCNR and CR were higher in the r-cDWI1000 datasets than in f-cDWI1000 and r-aDWI1000. Conclusion: High-resolution, high b-value computed DWI provides significantly better visualization of PDAC compared to the conventional high b-value computed and high-resolution high b-value images acquired by DWI.
Collapse
|
36
|
Digma LA, Feng CH, Conlin CC, Rodríguez-Soto AE, Zhong AY, Hussain TS, Lui AJ, Batra K, Simon AB, Karunamuni R, Kuperman J, Rakow-Penner R, Hahn ME, Dale AM, Seibert TM. Correcting B 0 inhomogeneity-induced distortions in whole-body diffusion MRI of bone. Sci Rep 2022; 12:265. [PMID: 34997164 PMCID: PMC8741963 DOI: 10.1038/s41598-021-04467-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 12/23/2021] [Indexed: 01/05/2023] Open
Abstract
Diffusion-weighted magnetic resonance imaging (DWI) of the musculoskeletal system has various applications, including visualization of bone tumors. However, DWI acquired with echo-planar imaging is susceptible to distortions due to static magnetic field inhomogeneities. This study aimed to estimate spatial displacements of bone and to examine whether distortion corrected DWI images more accurately reflect underlying anatomy. Whole-body MRI data from 127 prostate cancer patients were analyzed. The reverse polarity gradient (RPG) technique was applied to DWI data to estimate voxel-level distortions and to produce a distortion corrected DWI dataset. First, an anatomic landmark analysis was conducted, in which corresponding vertebral landmarks on DWI and anatomic T2-weighted images were annotated. Changes in distance between DWI- and T2-defined landmarks (i.e., changes in error) after distortion correction were calculated. In secondary analyses, distortion estimates from RPG were used to assess spatial displacements of bone metastases. Lastly, changes in mutual information between DWI and T2-weighted images of bone metastases after distortion correction were calculated. Distortion correction reduced anatomic error of vertebral DWI up to 29 mm. Error reductions were consistent across subjects (Wilcoxon signed-rank p < 10-20). On average (± SD), participants' largest error reduction was 11.8 mm (± 3.6). Mean (95% CI) displacement of bone lesions was 6.0 mm (95% CI 5.0-7.2); maximum displacement was 17.1 mm. Corrected diffusion images were more similar to structural MRI, as evidenced by consistent increases in mutual information (Wilcoxon signed-rank p < 10-12). These findings support the use of distortion correction techniques to improve localization of bone on DWI.
Collapse
Affiliation(s)
- Leonardino A Digma
- Department of Radiation Medicine and Applied Sciences, School of Medicine, University of California San Diego, 9500 Gilman Drive, Mail Code 0861, La Jolla, CA, 92093-0861, USA
| | - Christine H Feng
- Department of Radiation Medicine and Applied Sciences, School of Medicine, University of California San Diego, 9500 Gilman Drive, Mail Code 0861, La Jolla, CA, 92093-0861, USA
| | - Christopher C Conlin
- Department of Radiology, School of Medicine, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Ana E Rodríguez-Soto
- Department of Radiology, School of Medicine, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Allison Y Zhong
- Department of Radiation Medicine and Applied Sciences, School of Medicine, University of California San Diego, 9500 Gilman Drive, Mail Code 0861, La Jolla, CA, 92093-0861, USA
| | - Troy S Hussain
- Department of Radiation Medicine and Applied Sciences, School of Medicine, University of California San Diego, 9500 Gilman Drive, Mail Code 0861, La Jolla, CA, 92093-0861, USA
| | - Asona J Lui
- Department of Radiation Medicine and Applied Sciences, School of Medicine, University of California San Diego, 9500 Gilman Drive, Mail Code 0861, La Jolla, CA, 92093-0861, USA
| | - Kanha Batra
- Department of Electrical and Computer Engineering, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Aaron B Simon
- Department of Radiation Medicine and Applied Sciences, School of Medicine, University of California San Diego, 9500 Gilman Drive, Mail Code 0861, La Jolla, CA, 92093-0861, USA
| | - Roshan Karunamuni
- Department of Radiation Medicine and Applied Sciences, School of Medicine, University of California San Diego, 9500 Gilman Drive, Mail Code 0861, La Jolla, CA, 92093-0861, USA
| | - Joshua Kuperman
- Department of Radiology, School of Medicine, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Rebecca Rakow-Penner
- Department of Radiology, School of Medicine, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Michael E Hahn
- Department of Radiology, School of Medicine, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Anders M Dale
- Department of Radiology, School of Medicine, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Tyler M Seibert
- Department of Radiation Medicine and Applied Sciences, School of Medicine, University of California San Diego, 9500 Gilman Drive, Mail Code 0861, La Jolla, CA, 92093-0861, USA. .,Department of Radiology, School of Medicine, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA. .,Department of Bioengineering, UC San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA.
| |
Collapse
|
37
|
Sun K, Zhong Z, Xu Z, Dan G, Karaman MM, Zhou XJ. In-plane simultaneous multisegment imaging using a 2D RF pulse. Magn Reson Med 2022; 87:263-271. [PMID: 34350601 PMCID: PMC8616791 DOI: 10.1002/mrm.28956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 07/15/2021] [Accepted: 07/16/2021] [Indexed: 01/03/2023]
Abstract
PURPOSE To develop an in-plane simultaneous multisegment (IP-SMS) imaging technique using a 2D-RF pulse and to demonstrate its ability to achieve high spatial resolution in EPI while reducing image distortion. METHODS The proposed IP-SMS technique takes advantage of periodic replicates of the excitation profile of a 2D-RF pulse to simultaneously excite multiple segments within a slice. These segments were acquired over a reduced FOV and separated using a joint GRAPPA reconstruction by leveraging virtual coils that combined the physical coil sensitivity and 2D-RF pulse spatial response. Two excitations were used with complementary spatial response profiles to adequately cover a full FOV, producing a full-FOV image that had the benefits of reduced FOV with high spatial resolution and reduced distortion. The IP-SMS technique was implemented in a diffusion-weighted single-shot EPI sequence. Experimental demonstrations were performed on a phantom and healthy human brain. RESULTS In the phantom experiment, IP-SMS enabled a four-fold acceleration using an eight-channel coil without causing residual aliasing artifacts. In the human brain experiment, diffusion-weighted images with high in-plane resolution (1 × 1 mm2 ) and substantially reduced image distortion were obtained in all imaging planes in comparison with a commercial diffusion-weighted EPI sequence. The capability of IP-SMS for contiguous whole-brain coverage was also demonstrated. CONCLUSION The proposed IP-SMS technique can realize the benefits of reduced-FOV imaging while achieving a full-FOV coverage with good image quality and time efficiency.
Collapse
Affiliation(s)
- Kaibao Sun
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States
| | - Zheng Zhong
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States,Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States
| | - Zhongbiao Xu
- Department of Radiation Oncology, Guangdong Provincial People’s Hospital, Guangzhou, China
| | - Guangyu Dan
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States,Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States
| | - M. Muge Karaman
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States,Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States
| | - Xiaohong Joe Zhou
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States,Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States,Departments of Radiology and Neurosurgery, University of Illinois College of Medicine at Chicago, Chicago, IL, United States,Address correspondence to: Xiaohong Joe Zhou, PhD; ; Phone: 312-413-3979; Fax: 312-355-1637, Center for Magnetic Resonance Research, University of Illinois at Chicago, 2242 West Harrison Street, Suite 103, M/C 831 Chicago, IL 60612
| |
Collapse
|
38
|
Zhang M, Arango N, Stockmann JP, White J, Adalsteinsson E. Selective RF excitation designs enabled by time-varying spatially non-linear ΔB 0 fields with applications in fetal MRI. Magn Reson Med 2021; 87:2161-2177. [PMID: 34931714 PMCID: PMC8847339 DOI: 10.1002/mrm.29114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 10/22/2021] [Accepted: 11/17/2021] [Indexed: 11/08/2022]
Abstract
PURPOSE To demonstrate, through numerical simulations, novel designs of spatially selective radiofrequency (RF) excitations of the fetal brain by both a restricted 2D slice and 3D inner-volume selection. These designs exploit a single-channel RF pulse, conventional gradient fields, and the spatially non-linear ΔB0 fields of a multi-coil shim array, using an auto-differentiation optimization algorithm. METHODS The design algorithm jointly optimizes the RF pulse and the time-varying ΔB0 fields, which is produced by a 64-channel multi-coil ΔB0 body array to augment the RF and the linear gradient fields, using an auto-differentiation approach. Two design targets were specified, one a 4-mm thick slice with a limited in-slice extent in one dimension ("restricted slice"), and the other a 3D inner-volume selection encompassing the fetal brain ("inner volume"). The RF duration was limited to 2 ms for the restricted slice excitation and 6 ms for the inner-volume excitation. RESULTS Excitation profiles were achieved for both the restricted slice excitation task (one-minus-minimum magnitude, 8%) within the region of interest (ROI) and (maximum-minus-zero magnitude, 8%) in the suppressed regions and the fetal brain volume excitation task (13% and 9%, respectively). CONCLUSIONS The proposed joint design of RF and time-varying, spatially non-linear ΔB0 fields achieves the target excitation profiles with short RF pulse durations and demonstrates the potential to enhance fetal MRI with multi-channel body shim arrays.
Collapse
Affiliation(s)
- Molin Zhang
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Nicolas Arango
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Jason P Stockmann
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.,Department of Radiology, Harvard Medical School, Charlestown, Massachusetts, USA
| | - Jacob White
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Elfar Adalsteinsson
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.,Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.,Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| |
Collapse
|
39
|
Rodríguez-Soto AE, Andreassen MMS, Fang LK, Conlin CC, Park HH, Ahn GS, Bartsch H, Kuperman J, Vidić I, Ojeda-Fournier H, Wallace AM, Hahn M, Seibert TM, Jerome NP, Østlie A, Bathen TF, Goa PE, Rakow-Penner R, Dale AM. Characterization of the diffusion signal of breast tissues using multi-exponential models. Magn Reson Med 2021; 87:1938-1951. [PMID: 34904726 DOI: 10.1002/mrm.29090] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 10/12/2021] [Accepted: 11/01/2021] [Indexed: 12/15/2022]
Abstract
PURPOSE Restriction spectrum imaging (RSI) decomposes the diffusion-weighted MRI signal into separate components of known apparent diffusion coefficients (ADCs). The number of diffusion components and optimal ADCs for RSI are organ-specific and determined empirically. The purpose of this work was to determine the RSI model for breast tissues. METHODS The diffusion-weighted MRI signal was described using a linear combination of multiple exponential components. A set of ADC values was estimated to fit voxels in cancer and control ROIs. Later, the signal contributions of each diffusion component were estimated using these fixed ADC values. Relative-fitting residuals and Bayesian information criterion were assessed. Contrast-to-noise ratio between cancer and fibroglandular tissue in RSI-derived signal contribution maps was compared to DCE imaging. RESULTS A total of 74 women with breast cancer were scanned at 3.0 Tesla MRI. The fitting residuals of conventional ADC and Bayesian information criterion suggest that a 3-component model improves the characterization of the diffusion signal over a biexponential model. Estimated ADCs of triexponential model were D1,3 = 0, D2,3 = 1.5 × 10-3 , and D3,3 = 10.8 × 10-3 mm2 /s. The RSI-derived signal contributions of the slower diffusion components were larger in tumors than in fibroglandular tissues. Further, the contrast-to-noise and specificity at 80% sensitivity of DCE and a subset of RSI-derived maps were equivalent. CONCLUSION Breast diffusion-weighted MRI signal was best described using a triexponential model. Tumor conspicuity in breast RSI model is comparable to that of DCE without the use of exogenous contrast. These data may be used as differential features between healthy and malignant breast tissues.
Collapse
Affiliation(s)
- Ana E Rodríguez-Soto
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Maren M Sjaastad Andreassen
- Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway
| | - Lauren K Fang
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Christopher C Conlin
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Helen H Park
- School of Medicine, University of California San Diego, La Jolla, California, USA
| | - Grace S Ahn
- School of Medicine, University of California San Diego, La Jolla, California, USA
| | - Hauke Bartsch
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Joshua Kuperman
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Igor Vidić
- Department of Physics, NTNU, Norwegian University of Science and Technology, Trondheim, Norway
| | - Haydee Ojeda-Fournier
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Anne M Wallace
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Michael Hahn
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| | - Tyler M Seibert
- Department of Radiation Oncology, University of California San Diego, La Jolla, California, USA.,Department of Bioengineering, University of California San Diego, La Jolla, California, USA
| | - Neil Peter Jerome
- Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.,Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway
| | - Agnes Østlie
- Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway
| | - Tone Frost Bathen
- Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.,Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway
| | - Pål Erik Goa
- Department of Physics, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.,Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway
| | - Rebecca Rakow-Penner
- Department of Radiology, University of California San Diego, La Jolla, California, USA.,Department of Bioengineering, University of California San Diego, La Jolla, California, USA
| | - Anders M Dale
- Department of Radiology, University of California San Diego, La Jolla, California, USA
| |
Collapse
|
40
|
Sun K, Zhong Z, Dan G, Karaman M, Luo Q, Zhou XJ. Three-dimensional reduced field-of-view imaging (3D-rFOVI). Magn Reson Med 2021; 87:2372-2379. [PMID: 34894639 PMCID: PMC8847334 DOI: 10.1002/mrm.29121] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 10/31/2021] [Accepted: 11/25/2021] [Indexed: 12/23/2022]
Abstract
PURPOSE This study aimed at developing a 3D reduced field-of-view imaging (3D-rFOVI) technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve isotropic high spatial resolution and reduced image distortion in echo planar imaging (EPI). METHODS The proposed 3D-rFOVI technique takes advantage of a 2D RF pulse to excite a slab along the conventional slice-selection direction (i.e., z-direction) while limiting the spatial extent along the phase-encoded direction (i.e., y-direction) within the slab. The slab is phase-encoded in both through-slab and in-slab phase-encoded directions. The 3D-rFOVI technique was implemented at 3T in gradient-echo and spin-echo EPI pulse sequences for functional MRI (fMRI) and diffusion-weighted imaging (DWI), respectively. 3D-rFOVI experiments were performed on a phantom and human brain to illustrate image distortion reduction, as well as isotropic high spatial resolution, in comparison with 3D full-FOV imaging. RESULTS In both the phantom and the human brain, image voxel dislocation was substantially reduced by 3D-rFOVI when compared with full-FOV imaging. In the fMRI experiment with visual stimulation, 3D isotropic spatial resolution of (2 × 2 × 2 mm3 ) was achieved with an adequate signal-to-noise ratio (81.5) and blood oxygen level-dependent (BOLD) contrast (2.5%). In the DWI experiment, diffusion-weighted brain images with an isotropic resolution of (1 × 1 × 1 mm3 ) was obtained without appreciable image distortion. CONCLUSION This study indicates that 3D-rFOVI is a viable approach to 3D neuroimaging over a zoomed region.
Collapse
Affiliation(s)
- Kaibao Sun
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Zheng Zhong
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Guangyu Dan
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Muge Karaman
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Qingfei Luo
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Xiaohong Joe Zhou
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.,Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA.,Departments of Radiology and Neurosurgery, University of Illinois College of Medicine at Chicago, Chicago, Illinois, USA
| |
Collapse
|
41
|
Vinding MS, Goodwin DL, Kuprov I, Lund TE. Optimal control gradient precision trade-offs: Application to fast generation of DeepControl libraries for MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2021; 333:107094. [PMID: 34794089 DOI: 10.1016/j.jmr.2021.107094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 09/21/2021] [Accepted: 10/19/2021] [Indexed: 06/13/2023]
Abstract
We have recently demonstrated supervised deep learning methods for rapid generation of radiofrequency pulses in magnetic resonance imaging (https://doi.org/10.1002/mrm.27740, https://doi.org/10.1002/mrm.28667). Unlike the previous iterative optimization approaches, deep learning methods generate a pulse using a fixed number of floating-point operations - this is important in MRI, where patient-specific pulses preferably must be produced in real time. However, deep learning requires vast training libraries, which must be generated using the traditional methods, e.g., iterative quantum optimal control methods. Those methods are usually variations of gradient descent, and the calculation of the gradient of the performance metric with respect to the pulse waveform can be the most numerically intensive step. In this communication, we explore various ways in which the calculation of gradients in quantum optimal control theory may be accelerated. Four optimization avenues are explored: truncated commutator series expansions at zeroth and first order, a novel midpoint truncation scheme at first order, and the exact complex-step method. For the spin systems relevant to MRI, the first-order midpoint truncation is found to be sufficiently accurate, but also significantly faster than the machine precision gradient. This makes the generation of training databases for the machine learning methods considerably more realistic.
Collapse
Affiliation(s)
- Mads Sloth Vinding
- Center of Functionally Integrative Neuroscience (CFIN), Department of Clinical Medicine, Faculty of Health, Aarhus University, Denmark.
| | - David L Goodwin
- Institute for Biological Interfaces 4 - Magnetic Resonance, Karlsruhe Institute for Technology (KIT), Karlsruhe, Germany; Chemistry Research Laboratory, University of Oxford, Mansfield Road, Oxford, UK.
| | - Ilya Kuprov
- School of Chemistry, University of Southampton, Southampton SO17 1BJ, UK
| | - Torben Ellegaard Lund
- Center of Functionally Integrative Neuroscience (CFIN), Department of Clinical Medicine, Faculty of Health, Aarhus University, Denmark
| |
Collapse
|
42
|
Zhong Z, Sun K, Dan G, Luo Q, Zhou XJ. MRI with sub-millisecond temporal resolution over a reduced field of view. Magn Reson Med 2021; 86:3166-3174. [PMID: 34270138 PMCID: PMC8568630 DOI: 10.1002/mrm.28924] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 05/26/2021] [Accepted: 06/22/2021] [Indexed: 11/06/2022]
Abstract
PURPOSE To demonstrate an MRI pulse sequence-Sub-millisecond Periodic Event Encoded Dynamic Imaging with a reduced field of view (or rFOV-SPEEDI)-for decreasing the scan times while achieving sub-millisecond temporal resolution. METHODS rFOV-SPEEDI was based on a variation of SPEEDI, known as get-SPEEDI, which used each echo in an echo-train to sample a distinct k-space raster by synchronizing with a cyclic event. This can produce a set of time-resolved images of the cyclic event with a temporal resolution determined by the echo spacing (typically < 1 ms). rFOV-SPEEDI incorporated a 2D radiofrequency (RF) pulse into get-SPEEDI to limit the field of view (FOV), leading to reduction in phase-encoding steps and subsequently decreased scan times without compromising the spatial resolution. Two experiments were performed at 3T to illustrate rFOV-SPEEDI's capability of capturing fast-changing electric currents in a phantom and the rapid opening and closing of aortic valve in human subjects over reduced FOVs. The results were compared with those from full FOV get-SPEEDI. RESULTS In the first experiment, the rapidly varying currents (50-200 Hz) were successfully captured with a temporal resolution of 0.8 ms, and agreed well with the applied currents. In the second experiment, the rapid opening and closing processes of aortic valve were clearly visualized with a temporal resolution of 0.6 ms over a reduced FOV (12 × 12 cm2 ). In both experiments, the acquisition times of rFOV-SPEEDI were decreased by 33%-50% relative to full FOV get-SPEEDI acquisitions and the spatial resolution was maintained. CONCLUSION Reducing the FOV is a viable approach to shortening the scan times in SPEEDI, which is expected to help stimulate SPEEDI applications for studying ultrafast, cyclic physiological and biophysical processes over a focal region.
Collapse
Affiliation(s)
- Zheng Zhong
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Kaibao Sun
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Guangyu Dan
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Qingfei Luo
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Xiaohong Joe Zhou
- Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Radiology, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, Illinois, USA
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA
| |
Collapse
|
43
|
Schick F, Pieper CC, Kupczyk P, Almansour H, Keller G, Springer F, Mürtz P, Endler C, Sprinkart AM, Kaufmann S, Herrmann J, Attenberger UI. 1.5 vs 3 Tesla Magnetic Resonance Imaging: A Review of Favorite Clinical Applications for Both Field Strengths-Part 1. Invest Radiol 2021; 56:680-691. [PMID: 34324464 DOI: 10.1097/rli.0000000000000812] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
ABSTRACT Whole-body magnetic resonance imaging (MRI) systems with a field strength of 3 T have been offered by all leading manufacturers for approximately 2 decades and are increasingly used in clinical diagnostics despite higher costs. Technologically, MRI systems operating at 3 T have reached a high standard in recent years, as well as the 1.5-T devices that have been in use for a longer time. For modern MRI systems with 3 T, more complexity is required, especially for the magnet and the radiofrequency (RF) system (with multichannel transmission). Many clinical applications benefit greatly from the higher field strength due to the higher signal yield (eg, imaging of the brain or extremities), but there are also applications where the disadvantages of 3 T might outweigh the advantages (eg, lung imaging or examinations in the presence of implants). This review describes some technical features of modern 1.5-T and 3-T whole-body MRI systems, and reports on the experience of using both types of devices in different clinical settings, with all sections written by specialist radiologists in the respective fields.This first part of the review includes an overview of the general physicotechnical aspects of both field strengths and elaborates the special conditions of diffusion imaging. Many relevant aspects in the application areas of musculoskeletal imaging, abdominal imaging, and prostate diagnostics are discussed.
Collapse
Affiliation(s)
- Fritz Schick
- From the Section of Experimental Radiology, Department of Radiology, Diagnostic, and Interventional Radiology, University of Tübingen, Tübingen
| | | | - Patrick Kupczyk
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| | - Haidara Almansour
- Department of Radiology, Diagnostic, and Interventional Radiology, University of Tübingen, Tübingen, Germany
| | - Gabriel Keller
- Department of Radiology, Diagnostic, and Interventional Radiology, University of Tübingen, Tübingen, Germany
| | - Fabian Springer
- Department of Radiology, Diagnostic, and Interventional Radiology, University of Tübingen, Tübingen, Germany
| | - Petra Mürtz
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| | - Christoph Endler
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| | - Alois M Sprinkart
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| | - Sascha Kaufmann
- Department of Radiology, Diagnostic, and Interventional Radiology, University of Tübingen, Tübingen, Germany
| | - Judith Herrmann
- Department of Radiology, Diagnostic, and Interventional Radiology, University of Tübingen, Tübingen, Germany
| | - Ulrike I Attenberger
- Clinic for Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn
| |
Collapse
|
44
|
Harder FN, Kamal O, Kaissis GA, Heid I, Lohöfer FK, McTavish S, Van AT, Katemann C, Peeters JM, Karampinos DC, Makowski MR, Braren RF. Qualitative and Quantitative Comparison of Respiratory Triggered Reduced Field-of-View (FOV) Versus Full FOV Diffusion Weighted Imaging (DWI) in Pancreatic Pathologies. Acad Radiol 2021; 28 Suppl 1:S234-S243. [PMID: 33390324 DOI: 10.1016/j.acra.2020.12.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 12/11/2020] [Accepted: 12/11/2020] [Indexed: 02/08/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate the effects of a reduced field-of-view (rFOV) acquisition in diffusion-weighted magnetic resonance imaging of the pancreas. MATERIALS AND METHODS We enrolled 153 patients who underwent routine clinical MRI work-up including respiratory-triggered diffusion-weighted single-shot echo-planar imaging (DWI) with full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) and reduced field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) for suspected pancreatic pathology. Two experienced radiologists were asked to subjectively rate (Likert Scale 1-4) image quality (overall image quality, lesion conspicuity, anatomical detail, artifacts). In addition, quantitative image parameters were assessed (apparent diffusion coefficient, apparent signal to noise ratio, apparent contrast to noise ratio [CNR]). RESULTS All subjective metrics of image quality were rated in favor of rFOV DWI images compared to fFOV DWI images with substantial-to-high inter-rater reliability. Calculated ADC values of normal pancreas, pancreatic pathologies and reference tissues revealed no differences between both sequences. Whereas the apparent signal to noise ratio was higher in fFOV images, apparent CNR was higher in rFOV images. CONCLUSION rFOV DWI provides higher image quality and apparent CNR values, favorable in the analysis of pancreatic pathologies.
Collapse
Affiliation(s)
- Felix N Harder
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine
| | - Omar Kamal
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine; Department of Radiology, South Egypt Cancer Institute, Assiut University, Egypt
| | - Georgios A Kaissis
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine; Department of Computing, Faculty of Engineering, Imperial College of Science, Technology and Medicine, United Kingdom
| | - Irina Heid
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine
| | - Fabian K Lohöfer
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine
| | - Sean McTavish
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine
| | - Anh T Van
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine
| | | | | | - Dimitrios C Karampinos
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine
| | - Marcus R Makowski
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine
| | - Rickmer F Braren
- Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine.
| |
Collapse
|
45
|
Eren OC, Barlas BA, Saritas EU. 2D RF pulse design for optimized reduced field-of-view imaging at 1.5T and 3T. Magn Reson Imaging 2021; 85:210-216. [PMID: 34688847 DOI: 10.1016/j.mri.2021.10.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 10/15/2021] [Accepted: 10/16/2021] [Indexed: 10/20/2022]
Abstract
Two-dimensional spatially selective radiofrequency (2DRF) excitation pulses are widely used for reduced field-of-view (FOV) targeted high-resolution diffusion weighted imaging (DWI), especially for anatomically small regions such as the spinal cord and prostate. The reduction in FOV achieved by 2DRF pulses significantly improve the in-plane off-resonance artifacts in single-shot echo planar imaging (ss-EPI). However, long durations of 2DRF pulses create a sensitivity to through-plane off-resonance effects, especially at 3T where the off-resonance field doubles with respect to 1.5T. This work proposes a parameter-based optimization approach to design 2DRF pulses with blips along the slice-select axis, with the goal of maximizing slab sharpness while minimizing off-resonance effects on 1.5T and 3T MRI scanners, separately. Extensive Bloch simulations are performed to evaluate the off-resonance robustness of 2DRF pulses. Three different metrics are proposed to quantify the similarity between the actual and ideal 2D excitation profiles, based on the signals within and outside the targeted reduced-FOV region. In addition, simulations on a digital brain phantom are performed for visual comparison purposes. The results show that maintaining a sharp profile is the primary design requirement at 1.5T, necessitating the usage of relatively high slab sharpness with a time-bandwidth product (TBW) around 8-10. In contrast, off-resonance robustness is the primary design requirement at 3T, requiring the usage of a moderate slap sharpness with TBW around 5-7.
Collapse
Affiliation(s)
- Orhun Caner Eren
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey; Institute of Neuroinformatics, ETH Zurich, Zurich, Switzerland; Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich, Switzerland.
| | - Bahadir Alp Barlas
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey; National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.
| | - Emine Ulku Saritas
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey; National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey; Neuroscience Graduate Program, Bilkent University, Ankara, Turkey.
| |
Collapse
|
46
|
Hoar D, Lee PQ, Guida A, Patterson S, Bowen CV, Merrimen J, Wang C, Rendon R, Beyea SD, Clarke SE. Combined Transfer Learning and Test-Time Augmentation Improves Convolutional Neural Network-Based Semantic Segmentation of Prostate Cancer from Multi-Parametric MR Images. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 210:106375. [PMID: 34500139 DOI: 10.1016/j.cmpb.2021.106375] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 08/22/2021] [Indexed: 06/13/2023]
Abstract
PURPOSE Multiparametric MRI (mp-MRI) is a widely used tool for diagnosing and staging prostate cancer. The purpose of this study was to evaluate whether transfer learning, unsupervised pre-training and test-time augmentation significantly improved the performance of a convolutional neural network (CNN) for pixel-by-pixel prediction of cancer vs. non-cancer using mp-MRI datasets. METHODS 154 subjects undergoing mp-MRI were prospectively recruited, 16 of whom subsequently underwent radical prostatectomy. Logistic regression, random forest and CNN models were trained on mp-MRI data using histopathology as the gold standard. Transfer learning, unsupervised pre-training and test-time augmentation were used to boost CNN performance. Models were evaluated using Dice score and area under the receiver operating curve (AUROC) with leave-one-subject-out cross validation. Permutation feature importance testing was performed to evaluate the relative value of each MR contrast to CNN model performance. Statistical significance (p<0.05) was determined using the paired Wilcoxon signed rank test with Benjamini-Hochberg correction for multiple comparisons. RESULTS Baseline CNN outperformed logistic regression and random forest models. Transfer learning and unsupervised pre-training did not significantly improve CNN performance over baseline; however, test-time augmentation resulted in significantly higher Dice scores over both baseline CNN and CNN plus either of transfer learning or unsupervised pre-training. The best performing model was CNN with transfer learning and test-time augmentation (Dice score of 0.59 and AUROC of 0.93). The most important contrast was apparent diffusion coefficient (ADC), followed by Ktrans and T2, although each contributed significantly to classifier performance. CONCLUSIONS The addition of transfer learning and test-time augmentation resulted in significant improvement in CNN segmentation performance in a small set of prostate cancer mp-MRI data. Results suggest that these techniques may be more broadly useful for the optimization of deep learning algorithms applied to the problem of semantic segmentation in biomedical image datasets. However, further work is needed to improve the generalizability of the specific model presented herein.
Collapse
Affiliation(s)
- David Hoar
- Department of Electrical and Computer Engineering, Dalhousie University, Halifax, NS, Canada
| | - Peter Q Lee
- Faculty of Computer Science, Dalhousie University, Halifax, NS, Canada
| | - Alessandro Guida
- Biomedical Translational Imaging Centre, Nova Scotia Health Authority and IWK Health Centre, Halifax, NS, Canada
| | - Steven Patterson
- Biomedical Translational Imaging Centre, Nova Scotia Health Authority and IWK Health Centre, Halifax, NS, Canada
| | - Chris V Bowen
- Biomedical Translational Imaging Centre, Nova Scotia Health Authority and IWK Health Centre, Halifax, NS, Canada; Department of Diagnostic Radiology, Dalhousie University, Halifax, NS, Canada
| | | | - Cheng Wang
- Department of Pathology, Dalhousie University, Halifax, NS, Canada
| | - Ricardo Rendon
- Department of Urology, Dalhousie University, Halifax, NS, Canada
| | - Steven D Beyea
- Biomedical Translational Imaging Centre, Nova Scotia Health Authority and IWK Health Centre, Halifax, NS, Canada; Department of Diagnostic Radiology, Dalhousie University, Halifax, NS, Canada
| | - Sharon E Clarke
- Biomedical Translational Imaging Centre, Nova Scotia Health Authority and IWK Health Centre, Halifax, NS, Canada; Department of Diagnostic Radiology, Dalhousie University, Halifax, NS, Canada.
| |
Collapse
|
47
|
Cohen-Adad J, Alonso-Ortiz E, Abramovic M, Arneitz C, Atcheson N, Barlow L, Barry RL, Barth M, Battiston M, Büchel C, Budde M, Callot V, Combes AJE, De Leener B, Descoteaux M, de Sousa PL, Dostál M, Doyon J, Dvorak A, Eippert F, Epperson KR, Epperson KS, Freund P, Finsterbusch J, Foias A, Fratini M, Fukunaga I, Wheeler-Kingshott CAMG, Germani G, Gilbert G, Giove F, Gros C, Grussu F, Hagiwara A, Henry PG, Horák T, Hori M, Joers J, Kamiya K, Karbasforoushan H, Keřkovský M, Khatibi A, Kim JW, Kinany N, Kitzler H, Kolind S, Kong Y, Kudlička P, Kuntke P, Kurniawan ND, Kusmia S, Labounek R, Laganà MM, Laule C, Law CS, Lenglet C, Leutritz T, Liu Y, Llufriu S, Mackey S, Martinez-Heras E, Mattera L, Nestrasil I, O'Grady KP, Papinutto N, Papp D, Pareto D, Parrish TB, Pichiecchio A, Prados F, Rovira À, Ruitenberg MJ, Samson RS, Savini G, Seif M, Seifert AC, Smith AK, Smith SA, Smith ZA, Solana E, Suzuki Y, Tackley G, Tinnermann A, Valošek J, Van De Ville D, Yiannakas MC, Weber KA, Weiskopf N, Wise RG, Wyss PO, Xu J. Generic acquisition protocol for quantitative MRI of the spinal cord. Nat Protoc 2021; 16:4611-4632. [PMID: 34400839 PMCID: PMC8811488 DOI: 10.1038/s41596-021-00588-0] [Citation(s) in RCA: 52] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Accepted: 06/10/2021] [Indexed: 02/08/2023]
Abstract
Quantitative spinal cord (SC) magnetic resonance imaging (MRI) presents many challenges, including a lack of standardized imaging protocols. Here we present a prospectively harmonized quantitative MRI protocol, which we refer to as the spine generic protocol, for users of 3T MRI systems from the three main manufacturers: GE, Philips and Siemens. The protocol provides guidance for assessing SC macrostructural and microstructural integrity: T1-weighted and T2-weighted imaging for SC cross-sectional area computation, multi-echo gradient echo for gray matter cross-sectional area, and magnetization transfer and diffusion weighted imaging for assessing white matter microstructure. In a companion paper from the same authors, the spine generic protocol was used to acquire data across 42 centers in 260 healthy subjects. The key details of the spine generic protocol are also available in an open-access document that can be found at https://github.com/spine-generic/protocols . The protocol will serve as a starting point for researchers and clinicians implementing new SC imaging initiatives so that, in the future, inclusion of the SC in neuroimaging protocols will be more common. The protocol could be implemented by any trained MR technician or by a researcher/clinician familiar with MRI acquisition.
Collapse
Affiliation(s)
- Julien Cohen-Adad
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada.
- Functional Neuroimaging Unit, CRIUGM, University of Montreal, Montreal, Quebec, Canada.
- Mila-Quebec AI Institute, Montreal, Quebec, Canada.
| | - Eva Alonso-Ortiz
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada
| | - Mihael Abramovic
- Department of Radiology, Swiss Paraplegic Centre, Nottwil, Switzerland
| | - Carina Arneitz
- Department of Radiology, Swiss Paraplegic Centre, Nottwil, Switzerland
| | - Nicole Atcheson
- Centre for Advanced Imaging, The University of Queensland, Brisbane, Queensland, Australia
| | - Laura Barlow
- Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada
| | - Robert L Barry
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA
- Department of Radiology, Harvard Medical School, Boston, MA, USA
- Harvard-Massachusetts Institute of Technology Health Sciences & Technology, Cambridge, MA, USA
| | - Markus Barth
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Queensland, Australia
| | - Marco Battiston
- NMR Research Unit, Queen Square MS Centre, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, London, UK
| | - Christian Büchel
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Matthew Budde
- Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Virginie Callot
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
- APHM, Hopital Universitaire Timone, CEMEREM, Marseille, France
| | - Anna J E Combes
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Benjamin De Leener
- Department of Computer and Software Engineering, Polytechnique Montreal, Montreal, Quebec, Canada
- CHU Sainte-Justine Research Centre, Montreal, Quebec, Canada
| | - Maxime Descoteaux
- Centre de Recherche CHUS, CIMS, Sherbrooke, Quebec, Canada
- Sherbrooke Connectivity Imaging Lab (SCIL), Computer Science department, Université de Sherbrooke, Sherbrooke, Quebec, Canada
| | | | - Marek Dostál
- UHB - University Hospital Brno and Masaryk University, Department of Radiology and Nuclear Medicine, Brno, Czech Republic
| | - Julien Doyon
- McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada
| | - Adam Dvorak
- Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
| | - Falk Eippert
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Karla R Epperson
- Richard M. Lucas Center, Stanford University School of Medicine, Stanford, CA, USA
| | - Kevin S Epperson
- Richard M. Lucas Center, Stanford University School of Medicine, Stanford, CA, USA
| | - Patrick Freund
- Spinal Cord Injury Center Balgrist, University of Zurich, Zurich, Switzerland
| | - Jürgen Finsterbusch
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Alexandru Foias
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada
| | - Michela Fratini
- Institute of Nanotechnology, CNR, Rome, Italy
- IRCCS Santa Lucia Foundation, Rome, Italy
| | - Issei Fukunaga
- Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
| | - Claudia A M Gandini Wheeler-Kingshott
- NMR Research Unit, Queen Square MS Centre, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, London, UK
- Department of Brain and Behavioural Sciences, University of Pavia, Pavia, Italy
- Brain MRI 3T Research Centre, IRCCS Mondino Foundation, Pavia, Italy
| | - Giancarlo Germani
- Brain MRI 3T Research Centre, IRCCS Mondino Foundation, Pavia, Italy
| | | | - Federico Giove
- IRCCS Santa Lucia Foundation, Rome, Italy
- CREF - Museo storico della fisica e Centro studi e ricerche Enrico Fermi, Rome, Italy
| | - Charley Gros
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada
- Centre for Advanced Imaging, The University of Queensland, Brisbane, Queensland, Australia
| | - Francesco Grussu
- NMR Research Unit, Queen Square MS Centre, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, London, UK
- Radiomics Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Akifumi Hagiwara
- Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan
| | - Pierre-Gilles Henry
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| | - Tomáš Horák
- Multimodal and functional imaging laboratory, Central European Institute of Technology (CEITEC), Brno, Czech Republic
| | - Masaaki Hori
- Department of Radiology, Toho University Omori Medical Center, Tokyo, Japan
| | - James Joers
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| | - Kouhei Kamiya
- Department of Radiology, the University of Tokyo, Tokyo, Japan
| | - Haleh Karbasforoushan
- Interdepartmental Neuroscience Program, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
- Department of Psychiatry and Behavioral Sciences, School of Medicine, Stanford University, Stanford, CA, USA
| | - Miloš Keřkovský
- UHB - University Hospital Brno and Masaryk University, Department of Radiology and Nuclear Medicine, Brno, Czech Republic
| | - Ali Khatibi
- McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada
- Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham, UK
| | - Joo-Won Kim
- BioMedical Engineering and Imaging Institute (BMEII), Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Nawal Kinany
- Institute of Bioengineering/Center for Neuroprosthetics, Ecole Polytechnique Fédérale de Lausanne, Geneva, Switzerland
- Department of Radiology and Medical Informatics, University of Geneva, Geneva, Switzerland
| | - Hagen Kitzler
- Institute of Diagnostic and Interventional Neuroradiology, Carl Gustav Carus University Hospital, Technische Universität Dresden, Dresden, Germany
| | - Shannon Kolind
- Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada
- Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
- Department of Medicine (Neurology), University of British Columbia, Vancouver, British Columbia, Canada
| | - Yazhuo Kong
- CAS Key Laboratory of Behavioral Science, Institute of Psychology, Chinese Academy of Sciences, Beijing, China
- Department of Psychology, University of Chinese Academy of Sciences, Beijing, China
- Wellcome Centre For Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Petr Kudlička
- Multimodal and functional imaging laboratory, Central European Institute of Technology (CEITEC), Brno, Czech Republic
| | - Paul Kuntke
- Institute of Diagnostic and Interventional Neuroradiology, Carl Gustav Carus University Hospital, Technische Universität Dresden, Dresden, Germany
| | - Nyoman D Kurniawan
- Centre for Advanced Imaging, The University of Queensland, Brisbane, Queensland, Australia
| | - Slawomir Kusmia
- CUBRIC, Cardiff University, Wales, UK
- Centre for Medical Image Computing (CMIC), Medical Physics and Biomedical Engineering Department, University College London, London, UK
- Epilepsy Society MRI Unit, Chalfont St Peter, UK
| | - René Labounek
- Division of Clinical Behavioral Neuroscience, Department of Pediatrics, University of Minnesota, Minneapolis, MN, USA
- Departments of Neurology and Biomedical Engineering, University Hospital Olomouc, Olomouc, Czech Republic
| | | | - Cornelia Laule
- Departments of Radiology, Pathology & Laboratory Medicine, Physics & Astronomy; International Collaboration on Repair Discoveries (ICORD), University of British Columbia, Vancouver, British Columbia, Canada
| | - Christine S Law
- Division of Pain Medicine, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, CA, USA
| | - Christophe Lenglet
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| | - Tobias Leutritz
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Yaou Liu
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
- Tiantan Image Research Center, China National Clinical Research Center for Neurological Diseases, Beijing, China
| | - Sara Llufriu
- Center of Neuroimmunology, Laboratory of Advanced Imaging in Neuroimmunological Diseases, Hospital Clinic Barcelona, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Sean Mackey
- Division of Pain Medicine, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, CA, USA
| | - Eloy Martinez-Heras
- Center of Neuroimmunology, Laboratory of Advanced Imaging in Neuroimmunological Diseases, Hospital Clinic Barcelona, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Loan Mattera
- Fondation Campus Biotech Genève, Geneva, Switzerland
| | - Igor Nestrasil
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA
- Division of Clinical Behavioral Neuroscience, Department of Pediatrics, University of Minnesota, Minneapolis, MN, USA
| | - Kristin P O'Grady
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Radiology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Nico Papinutto
- UCSF Weill Institute for Neurosciences, Department of Neurology, University of California San Francisco, San Francisco, CA, USA
| | - Daniel Papp
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada
- Wellcome Centre For Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Deborah Pareto
- Neuroradiology Section, Vall d'Hebron University Hospital, Barcelona, Spain
| | - Todd B Parrish
- Interdepartmental Neuroscience Program, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Anna Pichiecchio
- Department of Brain and Behavioural Sciences, University of Pavia, Pavia, Italy
- Brain MRI 3T Research Centre, IRCCS Mondino Foundation, Pavia, Italy
| | - Ferran Prados
- NMR Research Unit, Queen Square MS Centre, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, London, UK
- Centre for Medical Image Computing (CMIC), Medical Physics and Biomedical Engineering Department, University College London, London, UK
- E-health Centre, Universitat Oberta de Catalunya, Barcelona, Spain
| | - Àlex Rovira
- Neuroradiology Section, Vall d'Hebron University Hospital, Barcelona, Spain
| | - Marc J Ruitenberg
- School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, Brisbane, Queensland, Australia
| | - Rebecca S Samson
- NMR Research Unit, Queen Square MS Centre, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, London, UK
| | - Giovanni Savini
- Brain MRI 3T Research Centre, IRCCS Mondino Foundation, Pavia, Italy
| | - Maryam Seif
- Spinal Cord Injury Center Balgrist, University of Zurich, Zurich, Switzerland
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Alan C Seifert
- BioMedical Engineering and Imaging Institute (BMEII), Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Alex K Smith
- Wellcome Centre For Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Seth A Smith
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Radiology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Zachary A Smith
- University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | - Elisabeth Solana
- Center of Neuroimmunology, Laboratory of Advanced Imaging in Neuroimmunological Diseases, Hospital Clinic Barcelona, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Yuichi Suzuki
- Department of Radiology, the University of Tokyo, Tokyo, Japan
| | | | - Alexandra Tinnermann
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jan Valošek
- Department of Neurology, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, Olomouc, Czech Republic
| | - Dimitri Van De Ville
- Institute of Bioengineering/Center for Neuroprosthetics, Ecole Polytechnique Fédérale de Lausanne, Geneva, Switzerland
- Department of Radiology and Medical Informatics, University of Geneva, Geneva, Switzerland
| | - Marios C Yiannakas
- NMR Research Unit, Queen Square MS Centre, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, University College London, London, UK
| | - Kenneth A Weber
- Division of Pain Medicine, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, CA, USA
| | - Nikolaus Weiskopf
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
- Felix Bloch Institute for Solid State Physics, Faculty of Physics and Earth Sciences, Leipzig University, Leipzig, Germany
| | - Richard G Wise
- CUBRIC, Cardiff University, Wales, UK
- Institute for Advanced Biomedical Technologies, Department of Neuroscience, Imaging and Clinical Sciences, "G. D'Annunzio University" of Chieti-Pescara, Chieti, Italy
| | - Patrik O Wyss
- Department of Radiology, Swiss Paraplegic Centre, Nottwil, Switzerland
| | - Junqian Xu
- BioMedical Engineering and Imaging Institute (BMEII), Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| |
Collapse
|
48
|
Yang H, Cui X, Zheng X, Li J, Yao Q, Li X, Qin J. Preliminary quantitative analysis of vertebral microenvironment changes in type 2 diabetes mellitus using FOCUS IVIM-DWI and IDEAL-IQ sequences. Magn Reson Imaging 2021; 84:84-91. [PMID: 34560231 DOI: 10.1016/j.mri.2021.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 09/10/2021] [Accepted: 09/16/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To explore the application of intravoxel incoherent motion diffusion-weighted imaging(IVIM-DWI) on account of field-of-view optimized and constrained undistorted single shot (FOCUS) and iteraterative decomposition of water and fat with echo asymmetry and least-squares estimation quantitation(IDEAL-IQ) sequences in evaluating the vertebral microenvironment changes of type 2 diabetes mellitus(T2DM) patients and the correlation with bone mineral density(BMD). METHOD 128 T2DM patients (mean age 63.4 ± 5.28 years) underwent both dual-energy X-ray absorptiometry (DEXA) and spine MRI. The FOCUS IVIM-DWI and IDEAL-IQ derived parameters of the vertebral body(L1, L2, L3, L4)were measured on corresponding maps of the lumbar spine. The subjects were divided into 3 groups according to T-scores as follows: normal (n = 37), osteopenia (n = 43), and osteoporosis(n = 48) group.One-way analysis of variance (ANOVA) were used to compare the vertebral parameters(ADCslow, ADCfast, f, FF, R2*) among three BMD cohorts.Receiver operating characteristic (ROC) analyses and Spearman's rank correlation were performed to test the diagnostic performance and the correlation between them respectively. RESULTS There were significant differences in vertebral ADCslow, ADCfast, FF and R2* between the three groups (P < 0.05).Statistically, BMD was moderately negatively correlated with FF (r = -0.584, P < 0.001) and weakly positively with ADCslow (r = 0.334, P < 0.001), meanwhile moderately positively correlated with R2*(r = 0.509, P < 0.001) and ADCfast(0.545, P < 0.001).ADCfast was moderately negatively correlated with FF (r = -0.417, P < 0.001), weakly positively correlated with R2*(0.359, P < 0.001).Compared with the area under the curve (AUC) of ADCslow, ADCfast, FF and R2*, the AUC of ADCfast was higher in identifying between normal and abnormal(osteopenia and osteoporosis), normal from osteopenia, while the AUC of FF was higher in identifying osteopenia from osteoporosis. CONCLUSIONS FOCUS IVIM-DWI and IDEAL-IQ of lumbar spine might be useful to evaluate the vertebral microenvironment changes of T2DM patients.
Collapse
Affiliation(s)
- Hui Yang
- Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an 271000, Shandong, China
| | - Xiaojie Cui
- Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an 271000, Shandong, China
| | - Xiuzhu Zheng
- Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an 271000, Shandong, China
| | - Jiang Li
- Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an 271000, Shandong, China
| | - Qianqian Yao
- Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an 271000, Shandong, China
| | - Xiaoqian Li
- Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an 271000, Shandong, China
| | - Jian Qin
- Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an 271000, Shandong, China.
| |
Collapse
|
49
|
High-fidelity diffusion tensor imaging of the cervical spinal cord using point-spread-function encoded EPI. Neuroimage 2021; 236:118043. [PMID: 33857617 DOI: 10.1016/j.neuroimage.2021.118043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 03/16/2021] [Accepted: 03/31/2021] [Indexed: 01/21/2023] Open
Abstract
Diffusion tensor imaging (DTI) of the spinal cord is technically challenging due to the size of its structure and susceptibility-induced field inhomogeneity, which impedes clinical applications. This study aimed to achieve high-fidelity spinal cord DTI with reasonable SNR and practical acquisition efficiency. Particularly, a distortion-free multi-shot EPI technique, namely point-spread-function encoded EPI (PSF-EPI), was adopted for diffusion imaging of the cervical spinal cord (CSC). The shot number can be reduced to six for sagittal scans through titled-CAIPI acceleration and partial Fourier undersampling, consequently rendering this technique beneficial in clinics. Fifteen healthy volunteers and seven patients with metallic implants underwent sagittal scans using tilted-CAIPI PSF-EPI at 3T. Unsuppressed fat signals were further removed by retrospective water/fat separation using the intrinsic chemical-shift encoded signals. Compared with multi-shot interleaved EPI method, highly accelerated PSF-EPI method provided evidently improved distortion reduction and higher consistency with anatomical references even with metallic implants. Additionally, axial DTI scans using PSF-EPI were also evaluated quantitatively, and the measured DTI metrics are similar to those obtained from the zonal oblique multi-slice EPI (ZOOM-EPI) method and reported values. The high anatomical consistency, practical scan time and quantitative reliability indicate PSF-EPI's clinical potential for CSC diffusion imaging.
Collapse
|
50
|
Tanabe M, Onoda H, Higashi M, Morooka R, Ihara K, Tanabe M, Matsukuma M, Iida E, Furukawa M, Ito K. Three-Dimensional (3D) Breath-Hold Zoomed MR Cholangiopancreatography (MRCP): Evaluation of Additive Value to Conventional 3D Navigator Triggering MRCP in Patients With Branch Duct Intraductal Papillary Mucinous Neoplasms. J Magn Reson Imaging 2021; 55:1234-1240. [PMID: 34331482 DOI: 10.1002/jmri.27866] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 07/20/2021] [Accepted: 07/21/2021] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND To resolve drawbacks of navigator triggering (NT) three-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP), several approaches were proposed to obtain 3D MRCP within a single breath-hold (BH). However, reduced field-of-view technique in the phase-encoding direction combined with two-dimensional spatially selective radiofrequency excitation pulses has not yet been applied to 3D BH MRCP. PURPOSE To investigate the feasibility and the complementary value of 3D BH zoomed MRCP to conventional 3D NT MRCP in patients with branch duct intraductal papillary mucinous neoplasms (BD-IPMNs) of the pancreas. STUDY TYPE Retrospective. POPULATION A total of 221 patients (116 male and 105 female, median age 73 years) with BD-IPMNs. FIELD STRENGTH/SEQUENCE 3.0 T/3D turbo spin echo ASSESSMENT: MR images were analyzed by three radiologists (R.M., H.O., M.T., with 1, 13, and 17 years of experience) to compare blurring and motion artifacts, background suppression, visualization of main pancreatic duct (MPD), conspicuity of BD-IPMN, and overall image quality. STATISTICAL TESTS Wilcoxon-signed rank, Mann-Whitney U, chi-squared or Fisher's exact tests (P < 0.05). RESULTS Image quality was significantly higher on 3D NT MRCP images than on 3D BH zoomed MRCP (median (interquartile range); background suppression, 4 (4-4) vs. 3 (3-4); visualization of MPD, 4 (3-4) vs. 4 (3-4), conspicuity of BD-IPMN, 4 (3-4) vs. 3 (3-4); and overall image quality, 3 (3-4) vs. 3 (3-3)). However, in 32 (14%) patients, 3D NT MRCP showed a score of 1 or 2 in overall image quality. Regarding the conspicuity of BD-IPMN, a conspicuity score of 1 or 2 was rendered in 31 (14%) patients in 3D NT MRCP group. Conversely, 3D BH zoomed MRCP showed a score of 3 or 4 in 29 (94%) of these 31 patients. DATA CONCLUSION 3D BH zoomed MRCP plays a complementary role to 3D NT MRCP, and may improve the conspicuity of BD-IPMNs in patients with irregular breathing pattern. LEVEL OF EVIDENCE 4 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Masahiro Tanabe
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Hideko Onoda
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Mayumi Higashi
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Ryoko Morooka
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Kenichiro Ihara
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Masaya Tanabe
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Miwa Matsukuma
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Etsushi Iida
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Matakazu Furukawa
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Katsuyoshi Ito
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| |
Collapse
|