Muslu Y, Tamada D, Roberts NT, Cashen TA, Mandava S, Kecskemeti SR, Hernando D, Reeder SB. Free-breathing, fat-corrected T 1 mapping of the liver with stack-of-stars MRI, and joint estimation of T 1, PDFF, R 2 * , and B 1 + . Magn Reson Med 2024. [PMID: 38923009 DOI: 10.1002/mrm.30182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 05/03/2024] [Accepted: 05/16/2024] [Indexed: 06/28/2024]
Abstract
PURPOSE Quantitative T1 mapping has the potential to replace biopsy for noninvasive diagnosis and quantitative staging of chronic liver disease. Conventional T1 mapping methods are confounded by fat andB 1 + $$ {B}_1^{+} $$ inhomogeneities, resulting in unreliable T1 estimations. Furthermore, these methods trade off spatial resolution and volumetric coverage for shorter acquisitions with only a few images obtained within a breath-hold. This work proposes a novel, volumetric (3D), free-breathing T1 mapping method to account for multiple confounding factors in a single acquisition. THEORY AND METHODS Free-breathing, confounder-corrected T1 mapping was achieved through the combination of non-Cartesian imaging, magnetization preparation, chemical shift encoding, and a variable flip angle acquisition. A subspace-constrained, locally low-rank image reconstruction algorithm was employed for image reconstruction. The accuracy of the proposed method was evaluated through numerical simulations and phantom experiments with a T1/proton density fat fraction phantom at 3.0 T. Further, the feasibility of the proposed method was investigated through contrast-enhanced imaging in healthy volunteers, also at 3.0 T. RESULTS The method showed excellent agreement with reference measurements in phantoms across a wide range of T1 values (200 to 1000 ms, slope = 0.998 (95% confidence interval (CI) [0.963 to 1.035]), intercept = 27.1 ms (95% CI [0.4 54.6]), r2 = 0.996), and a high level of repeatability. In vivo imaging studies demonstrated moderate agreement (slope = 1.099 (95% CI [1.067 to 1.132]), intercept = -96.3 ms (95% CI [-82.1 to -110.5]), r2 = 0.981) compared to saturation recovery-based T1 maps. CONCLUSION The proposed method produces whole-liver, confounder-corrected T1 maps through simultaneous estimation of T1, proton density fat fraction, andB 1 + $$ {B}_1^{+} $$ in a single, free-breathing acquisition and has excellent agreement with reference measurements in phantoms.
Collapse
Affiliation(s)
- Yavuz Muslu
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Daiki Tamada
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | | | | | | | - Diego Hernando
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA
- Department of Emergency Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
2
|
Huaroc Moquillaza E, Weiss K, Stelter J, Steinhelfer L, Lee YJ, Amthor T, Koken P, Makowski MR, Braren R, Doneva M, Karampinos DC. Accelerated liver water T 1 mapping using single-shot continuous inversion-recovery spiral imaging. NMR IN BIOMEDICINE 2024; 37:e5097. [PMID: 38269568 DOI: 10.1002/nbm.5097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 11/21/2023] [Accepted: 12/06/2023] [Indexed: 01/26/2024]
Abstract
PURPOSE Liver T1 mapping techniques typically require long breath holds or long scan time in free-breathing, need correction for B 1 + inhomogeneities and process composite (water and fat) signals. The purpose of this work is to accelerate the multi-slice acquisition of liver water selective T1 (wT1) mapping in a single breath hold, improving the k-space sampling efficiency. METHODS The proposed continuous inversion-recovery (IR) Look-Locker methodology combines a single-shot gradient echo spiral readout, Dixon processing and a dictionary-based analysis for liver wT1 mapping at 3 T. The sequence parameters were adapted to obtain short scan times. The influence of fat, B 1 + inhomogeneities and TE on the estimation of T1 was first assessed using simulations. The proposed method was then validated in a phantom and in 10 volunteers, comparing it with MRS and the modified Look-Locker inversion-recovery (MOLLI) method. Finally, the clinical feasibility was investigated by comparing wT1 maps with clinical scans in nine patients. RESULTS The phantom results are in good agreement with MRS. The proposed method encodes the IR-curve for the liver wT1 estimation, is minimally sensitive to B 1 + inhomogeneities and acquires one slice in 1.2 s. The volunteer results confirmed the multi-slice capability of the proposed method, acquiring nine slices in a breath hold of 11 s. The present work shows robustness to B 1 + inhomogeneities (wT 1 , No B 1 + = 1.07 wT 1 , B 1 + - 45.63 , R 2 = 0.99 ) , good repeatability (wT 1 , 2 ° = 1 . 0 wT 1 , 1 ° - 2.14 , R 2 = 0.96 ) and is in better agreement with MRS (wT 1 = 0.92 wT 1 MRS + 103.28 , R 2 = 0.38 ) than is MOLLI (wT 1 MOLLI = 0.76 wT 1 MRS + 254.43 , R 2 = 0.44 ) . The wT1 maps in patients captured diverse lesions, thus showing their clinical feasibility. CONCLUSION A single-shot spiral acquisition can be combined with a continuous IR Look-Locker method to perform rapid repeatable multi-slice liver water T1 mapping at a rate of 1.2 s per slice without a B 1 + map. The proposed method is suitable for nine-slice liver clinical applications acquired in a single breath hold of 11 s.
Collapse
Affiliation(s)
- Elizabeth Huaroc Moquillaza
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Jonathan Stelter
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Lisa Steinhelfer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | | | | | - Marcus R Makowski
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Rickmer Braren
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| |
Collapse
|
3
|
Ohtani T, Kanamoto M, Ozaki K, Yachida T, Matta Y, Kidoya E. [Usefulness of Breath-hold DWI Focused on the Hepatic Dome in EOB-MRI]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2023; 79:794-801. [PMID: 37331799 DOI: 10.6009/jjrt.2023-1380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2023]
Abstract
PURPOSE Respiratory-triggered-diffusion-weighted imaging (R-DWI) of the liver often results in poor image quality under the diaphragmatic dome on the cephalic side of the liver (hepatic dome) secondary to magnetic field inhomogeneity in liver magnetic resonance imaging (MRI). Hence, the usefulness of additional breath-hold-DWI (B-DWI) focusing on the hepatic dome was investigated. METHODS A total of 22 patients (14 men and 8 women; mean age 69.0±11.7 years) who underwent ethoxybenzyl (EOB)-MRI at our hospital between July and August, 2022 using a 3.0 T MRI system were included. One radiologist and three radiology technologists visually assessed the visibility of R-DWI and B-DWI in the hepatic dome on a 4-point scale (1 to 4). Additionally, the apparent diffusion coefficient (ADC) values of the hepatic parenchyma on each DWI were compared. RESULTS B-DWI improved visibility in the hepatic dome compared to R-DWI (2.67±0.71 vs. 3.25±0.43, p<0.05). No significant difference was found in the ADC values for each DWI. CONCLUSION B-DWI has excellent visibility in the hepatic dome and is expected to complement R-DWI. Therefore, B-DWI is very useful as an additional imaging in EOB-MRI.
Collapse
Affiliation(s)
| | | | - Kumi Ozaki
- Department of Radiology, University of Fukui Hospital
| | | | - Yuki Matta
- Radiological Center, University of Fukui Hospital
| | - Eiji Kidoya
- Radiological Center, University of Fukui Hospital
| |
Collapse
|
4
|
Dillman JR, Tkach JA, Pedneker A, Trout AT. Quantitative abdominal magnetic resonance imaging in children-special considerations. Abdom Radiol (NY) 2022; 47:3069-3077. [PMID: 34196762 DOI: 10.1007/s00261-021-03191-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 06/20/2021] [Accepted: 06/21/2021] [Indexed: 01/18/2023]
Abstract
The use of quantitative MRI methods for assessment of the abdomen in children has become commonplace over the past decade. Increasingly employed methods include MR elastography, chemical shift encoded (CSE) MR imaging for determination of proton density fat fraction, diffusion-weighted imaging, and a variety of relaxometry techniques, such as T1 and T2* mapping. These techniques can be used in a variety of settings to distinguish normal from abnormal tissue as well as determine the severity of disease. The performance of quantitative MRI methods in the pediatric population presents unique challenges as compared to adult populations. These challenges relate to multiple factors, including patient size, pediatric physiology, inability to breath hold, and greater physical motion during the examination. The purpose of this review article is to review quantitative MRI methods that may be used in clinical practice to assess the pediatric abdomen and to discuss special considerations when performing these techniques in children.
Collapse
Affiliation(s)
- Jonathan R Dillman
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229, USA.
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| | - Jean A Tkach
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Amol Pedneker
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
5
|
Antoniou A, Georgiou L, Christodoulou T, Panayiotou N, Ioannides C, Zamboglou N, Damianou C. MR relaxation times of agar-based tissue-mimicking phantoms. J Appl Clin Med Phys 2022; 23:e13533. [PMID: 35415875 PMCID: PMC9121050 DOI: 10.1002/acm2.13533] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 12/29/2021] [Indexed: 12/31/2022] Open
Abstract
Agar gels were previously proven capable of accurately replicating the acoustical and thermal properties of real tissue and widely used for the construction of tissue-mimicking phantoms (TMPs) for focused ultrasound (FUS) applications. Given the current popularity of magnetic resonance-guided FUS (MRgFUS), we have investigated the MR relaxation times T1 and T2 of different mixtures of agar-based phantoms. Nine TMPs were constructed containing agar as the gelling agent and various concentrations of silicon dioxide and evaporated milk. An agar-based phantom doped with wood powder was also evaluated. A series of MR images were acquired in a 1.5 T scanner for T1 and T2 mapping. T2 was predominantly affected by varying agar concentrations. A trend toward decreasing T1 with an increasing concentration of evaporated milk was observed. The addition of silicon dioxide decreased both relaxation times of pure agar gels. The proposed phantoms have great potential for use with the continuously emerging MRgFUS technology. The MR relaxation times of several body tissues can be mimicked by adjusting the concentration of ingredients, thus enabling more accurate and realistic MRgFUS studies.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Leonidas Georgiou
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | | | - Natalie Panayiotou
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | - Cleanthis Ioannides
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | - Nikolaos Zamboglou
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| |
Collapse
|
6
|
Serai SD. Basics of magnetic resonance imaging and quantitative parameters T1, T2, T2*, T1rho and diffusion-weighted imaging. Pediatr Radiol 2022; 52:217-227. [PMID: 33856502 DOI: 10.1007/s00247-021-05042-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 01/18/2021] [Accepted: 03/01/2021] [Indexed: 01/27/2023]
Abstract
Magnetic resonance imaging is widely available and accepted as the imaging method of choice for many pediatric body imaging applications. Traditionally, it has been used in a qualitative way, where the images are reported non-numerically by radiologists. But now MRI machines have built-in post-processing software connected to the scanner and the database of MR images. This setting enables and encourages simple quantitative analysis of MR images. In this paper, the author reviews the fundamentals of MRI and discusses the most common quantitative MRI techniques for body imaging: T1, T2, T2*, T1rho and diffusion-weighted imaging (DWI). For each quantitative imaging method, this article reviews the technique, its measurement mechanism, and selected clinical applications to body imaging.
Collapse
Affiliation(s)
- Suraj D Serai
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA. .,Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
7
|
Antoniou A, Damianou C. MR relaxation properties of tissue-mimicking phantoms. ULTRASONICS 2022; 119:106600. [PMID: 34627028 DOI: 10.1016/j.ultras.2021.106600] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/20/2021] [Accepted: 09/21/2021] [Indexed: 06/13/2023]
Abstract
High quality tissue-mimicking phantoms (TMPs) have a critical role in the preclinical testing of emerging modalities for diagnosis and therapy. TMPs capable of accurately mimicking real tissue in Magnetic Resonance guided Focused Ultrasound (MRgFUS) applications should be fabricated with precise T1 and T2 relaxation times. Given the current popularity of the MRgFUS technology, we herein performed a systematic review on the MR relaxation properties of different phantoms types. Polyacrylamide (PAA) and agar based phantoms were proven capable of accurately replicating critical thermal, acoustical, and MR relaxation properties of various body tissues. Although gelatin phantoms were also proven factional in this regard, they lack the capacity to withstand ablation temperatures, and thus, are only recommended for hyperthermia applications. Other gelling agents identified in the literature are Poly-vinyl alcohol (PVA), Polyvinyl Chloride (PVC), silicone, and TX-150/ TX-151; however, their efficacy in thermal studies is yet to be established. PAA gels are favorable in that they offer optical transparency enabling direct visualization of coagulative lesions. On the other hand, agar phantoms have lower preparation costs and were proven very promising for use with the MRgFUS technology, without the toxicity issues related to the preparation and storage of PAA materials. Remarkably, agar turned out to be the prominent modifier of the T2 relaxation time even for phantoms containing other types of gelling agents instead of agar. This review could be useful in manufacturing realistic MRgFUS phantoms while simultaneously indicating an opportunity for further research in the field with a particular focus on the MR behavior of agar-based TMPs.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
| |
Collapse
|
8
|
Feng L, Liu F, Soultanidis G, Liu C, Benkert T, Block KT, Fayad ZA, Yang Y. Magnetization-prepared GRASP MRI for rapid 3D T1 mapping and fat/water-separated T1 mapping. Magn Reson Med 2021; 86:97-114. [PMID: 33580909 PMCID: PMC8197608 DOI: 10.1002/mrm.28679] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 12/18/2020] [Accepted: 12/22/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE This study aimed to (i) develop Magnetization-Prepared Golden-angle RAdial Sparse Parallel (MP-GRASP) MRI using a stack-of-stars trajectory for rapid free-breathing T1 mapping and (ii) extend MP-GRASP to multi-echo acquisition (MP-Dixon-GRASP) for fat/water-separated (water-specific) T1 mapping. METHODS An adiabatic non-selective 180° inversion-recovery pulse was added to a gradient-echo-based golden-angle stack-of-stars sequence for magnetization-prepared 3D single-echo or 3D multi-echo acquisition. In combination with subspace-based GRASP-Pro reconstruction, the sequence allows for standard T1 mapping (MP-GRASP) or fat/water-separated T1 mapping (MP-Dixon-GRASP), respectively. The accuracy of T1 mapping using MP-GRASP was evaluated in a phantom and volunteers (brain and liver) against clinically accepted reference methods. The repeatability of T1 estimation was also assessed in the phantom and volunteers. The performance of MP-Dixon-GRASP for water-specific T1 mapping was evaluated in a fat/water phantom and volunteers (brain and liver). RESULTS ROI-based mean T1 values are correlated between the references and MP-GRASP in the phantom (R2 = 1.0), brain (R2 = 0.96), and liver (R2 = 0.73). MP-GRASP achieved good repeatability of T1 estimation in the phantom (R2 = 1.0), brain (R2 = 0.99), and liver (R2 = 0.82). Water-specific T1 is different from in-phase and out-of-phase composite T1 (composite T1 when fat and water signal are mixed in phase or out of phase) both in the phantom and volunteers. CONCLUSION This work demonstrated the initial performance of MP-GRASP and MP-Dixon-GRASP MRI for rapid 3D T1 mapping and 3D fat/water-separated T1 mapping in the brain (without motion) and in the liver (during free breathing). With fat/water-separated T1 estimation, MP-Dixon-GRASP could be potentially useful for imaging patients with fatty-liver diseases.
Collapse
Affiliation(s)
- Li Feng
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Fang Liu
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Georgios Soultanidis
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Chenyu Liu
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Thomas Benkert
- MR Application Development, Siemens Healthcare GmbH, Erlangen, Germany
| | - Kai Tobias Block
- MR Application Development, Siemens Healthcare GmbH, Erlangen, Germany
- Center for Advanced Imaging Innovation and Research (CAIR), New York University School of Medicine, New York, NY, USA
| | - Zahi A. Fayad
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Yang Yang
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| |
Collapse
|
9
|
Evrimler S, Swensson JK, Are VS, Tirkes T, Vuppalanchi R, Akisik F. Quantitative assessment of disease severity of primary sclerosing cholangitis with T1 mapping and extracellular volume imaging. Abdom Radiol (NY) 2021; 46:2433-2443. [PMID: 33135100 DOI: 10.1007/s00261-020-02839-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 10/16/2020] [Accepted: 10/20/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE Assess the relationship between liver T1 relaxation time and extracellular volume (ECV) fraction and the disease severity of primary sclerosing cholangitis (PSC). METHODS This retrospective study included 93 patients with PSC and 66 healthy patients in the control group. T1 relaxation times were measured in the right and left lobe, as well as in the area of stricture. T1PSC and ECVPSC were calculated by averaging T1 and ECV of both lobes and stricture site. T1 and ECV were compared between the two groups and according to PSC phenotypes and severity based on Mayo Risk Score (MRS). We also examined the relationship between T1 and ECV with non-invasive measures of fibrosis such as Fibrosis-4 index (FIB-4) and liver stiffness measurement (LSM) by transient elastography. RESULTS Mean liver T1 (774 ± 111 ms, p < 0.001) and liver ECV (0.40 ± 0.14, p < 0.05) were significantly higher with both large-duct and small-duct-type PSC which may lack classic imaging findings on MRCP compared to the control group (p < 0.001). T1PSC and ECVPSC showed weak-moderate correlation with LSM, FIB-4, and MRS (p < 0.05). Cut-off values of liver T1 to detect patients in low-risk and high-risk MRS groups were 677 ms (AUC: 0.68, sensitivity: 76%, specificity: 53%, p = 0.03) and 743 ms (AUC: 0.83, sensitivity: 79%, specificity: 76%, p < 0.001), respectively. CONCLUSION T1 relaxation time and ECV fraction can be used for quantitative assessment of disease severity in patients with PSC.
Collapse
|
10
|
Li Z, Fu Z, Keerthivasan M, Bilgin A, Johnson K, Galons JP, Vedantham S, Martin DR, Altbach MI. Rapid high-resolution volumetric T 1 mapping using a highly accelerated stack-of-stars Look Locker technique. Magn Reson Imaging 2021; 79:28-37. [PMID: 33722634 PMCID: PMC8107135 DOI: 10.1016/j.mri.2021.03.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 03/03/2021] [Accepted: 03/03/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE To develop a fast volumetric T1 mapping technique. MATERIALS AND METHODS A stack-of-stars (SOS) Look Locker technique based on the acquisition of undersampled radial data (>30× relative to Nyquist) and an efficient multi-slab excitation scheme is presented. A principal-component based reconstruction is used to reconstruct T1 maps. Computer simulations were performed to determine the best choice of partitions per slab and degree of undersampling. The technique was validated in phantoms against reference T1 values measured with a 2D Cartesian inversion-recovery spin-echo technique. The SOS Look Locker technique was tested in brain (n = 4) and prostate (n = 5). Brain T1 mapping was carried out with and without kz acceleration and results between the two approaches were compared. Prostate T1 mapping was compared to standard techniques. A reproducibility study was conducted in brain and prostate. Statistical analyses were performed using linear regression and Bland Altman analysis. RESULTS Phantom T1 values showed excellent correlations between SOS Look Locker and the inversion-recovery spin-echo reference (r2 = 0.9965; p < 0.0001) and between SOS Look Locker with slab-selective and non-slab selective inversion pulses (r2 = 0.9999; p < 0.0001). In vivo results showed that full brain T1 mapping (1 mm3) with kz acceleration is achieved in 4 min 21 s. Full prostate T1 mapping (0.9 × 0.9 × 4 mm3) is achieved in 2 min 43 s. T1 values for brain and prostate were in agreement with literature values. A reproducibility study showed coefficients of variation in the range of 0.18-0.2% (brain) and 0.15-0.18% (prostate). CONCLUSION A rapid volumetric T1 mapping technique was developed. The technique enables high-resolution T1 mapping with adequate anatomical coverage in a clinically acceptable time.
Collapse
Affiliation(s)
- Zhitao Li
- Department of Electrical and Computer Engineering, the University of Arizona, Tucson, AZ 85721, USA; Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA
| | - Zhiyang Fu
- Department of Electrical and Computer Engineering, the University of Arizona, Tucson, AZ 85721, USA; Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA
| | - Mahesh Keerthivasan
- Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA; Siemens Healthcare USA, Tucson, AZ 85724, USA
| | - Ali Bilgin
- Department of Electrical and Computer Engineering, the University of Arizona, Tucson, AZ 85721, USA; Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA; Department of Biomedical Engineering, the University of Arizona, Tucson, AZ 85721, USA
| | - Kevin Johnson
- Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA
| | | | | | - Diego R Martin
- Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA
| | - Maria I Altbach
- Department of Medical Imaging, the University of Arizona, Tucson, AZ 85724, USA; Department of Biomedical Engineering, the University of Arizona, Tucson, AZ 85721, USA.
| |
Collapse
|
11
|
Waterton JC. Survey of water proton longitudinal relaxation in liver in vivo. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2021; 34:779-789. [PMID: 33978944 PMCID: PMC8578172 DOI: 10.1007/s10334-021-00928-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 04/05/2021] [Accepted: 04/27/2021] [Indexed: 12/13/2022]
Abstract
Objective To determine the variability, and preferred values, for normal liver longitudinal water proton relaxation rate R1 in the published literature. Methods Values of mean R1 and between-subject variance were obtained from literature searching. Weighted means were fitted to a heuristic and to a model. Results After exclusions, 116 publications (143 studies) remained, representing apparently normal liver in 3392 humans, 99 mice and 249 rats. Seventeen field strengths were included between 0.04 T and 9.4 T. Older studies tended to report higher between-subject coefficients of variation (CoV), but for studies published since 1992, the median between-subject CoV was 7.4%, and in half of those studies, measured R1 deviated from model by 8.0% or less. Discussion The within-study between-subject CoV incorporates repeatability error and true between-subject variation. Between-study variation also incorporates between-population variation, together with bias from interactions between methodology and physiology. While quantitative relaxometry ultimately requires validation with phantoms and analysis of propagation of errors, this survey allows investigators to compare their own R1 and variability values with the range of existing literature. Supplementary Information The online version contains supplementary material available at 10.1007/s10334-021-00928-x.
Collapse
Affiliation(s)
- John Charles Waterton
- Centre for Imaging Sciences, Division of Informatics Imaging and Data Sciences, School of Health Sciences, Faculty of Biology Medicine and Health, University of Manchester, Manchester Academic Health Sciences Centre, Oxford Road, Manchester, M13 9PL, UK. .,Bioxydyn Ltd, Rutherford House, Manchester Science Park, Pencroft Way, Manchester, M15 6SZ, UK.
| |
Collapse
|
12
|
Huang SS, Boyacioglu R, Bolding R, MacAskill C, Chen Y, Griswold MA. Free-Breathing Abdominal Magnetic Resonance Fingerprinting Using a Pilot Tone Navigator. J Magn Reson Imaging 2021; 54:1138-1151. [PMID: 33949741 DOI: 10.1002/jmri.27673] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 04/15/2021] [Accepted: 04/16/2021] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Quantitative T1 and T2 mapping in the abdomen provides valuable information in tissue characterization but is technically challenging due to respiratory motions. The proposed technique integrates magnetic resonance fingerprinting (MRF) and pilot tone (PT) navigator with retrospective gating to provide simultaneous quantification of multiple tissue properties in a single acquisition without breath-holding or patient set-up. PURPOSE To develop a free-breathing abdominal MRF technique for quantitative mapping in the abdomen. STUDY TYPE Prospective. POPULATION Twelve healthy volunteers. FIELD STRENGTH/SEQUENCE A 3 T, two-dimensional (2D) and three-dimensional (3D) spiral MRF sequence with fast imaging with steady-state free precession (FISP) readout. ASSESSMENT The PT navigator was compared to standard respiratory belt performance. The T1 and T2 values acquired using 2D and 3D MRF with and without PT were obtained in a phantom and compared to reference values. Digital phantom simulation was performed to evaluate PT MRF reconstruction with varying breathing patterns. In the in vivo studies, T1 and T2 values derived from PT 2D MRF were compared to 2D breath-hold MRF. T1 and T2 values derived from PT 3D MRF were compared to published values. STATISTICAL TESTS Principal component analysis (PCA), linear regression, relative error, Pearson correlation, paired Student's t-test, Bland-Altman Analysis. RESULTS The phantom study showed PT MRF T1 values had a mean difference of 0.2% ± 0.1%, and T2 values had a mean difference of 0.1% ± 0.4% when compared to no-PT MRF values. The digital phantom experiment suggested the T1 and T2 maps at both end-exhalation and end-inhalation states resemble the corresponding ground-truth maps. DATA CONCLUSION The phantom study showed good agreement between MRF T1 and T2 values and with reference values. In vivo studies demonstrated that 2D and 3D quantitative imaging in the abdomen could be achieved with integration of PT navigation with MRF reconstruction using retrospective gating of respiratory motion. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Sherry S Huang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Rasim Boyacioglu
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Reid Bolding
- Department of Physics, Case Western Reserve University, Cleveland, Ohio, USA
| | - Christina MacAskill
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Yong Chen
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Mark A Griswold
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
13
|
Wang X, Rosenzweig S, Scholand N, Holme HCM, Uecker M. Model-based reconstruction for simultaneous multi-slice T1 mapping using single-shot inversion-recovery radial FLASH. Magn Reson Med 2021; 85:1258-1271. [PMID: 32936487 PMCID: PMC10409492 DOI: 10.1002/mrm.28497] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 08/03/2020] [Accepted: 08/04/2020] [Indexed: 01/17/2023]
Abstract
PURPOSE To develop a single-shot multi-slice T 1 mapping method by combing simultaneous multi-slice (SMS) excitations, single-shot inversion-recovery (IR) radial fast low-angle shot (FLASH), and a nonlinear model-based reconstruction method. METHODS SMS excitations are combined with a single-shot IR radial FLASH sequence for data acquisition. A previously developed single-slice calibrationless model-based reconstruction is extended to SMS, formulating the estimation of parameter maps and coil sensitivities from all slices as a single nonlinear inverse problem. Joint-sparsity constraints are further applied to the parameter maps to improve T 1 precision. Validations of the proposed method are performed for a phantom and for the human brain and liver in 6 healthy adult subjects. RESULTS Phantom results confirm good T 1 accuracy and precision of the simultaneously acquired multi-slice T 1 maps in comparison to single-slice references. In vivo human brain studies demonstrate the better performance of SMS acquisitions compared to the conventional spoke-interleaved multi-slice acquisition using model-based reconstruction. Aside from good accuracy and precision, the results of 6 healthy subjects in both brain and abdominal studies confirm good repeatability between scan and re-scans. The proposed method can simultaneously acquire T 1 maps for 5 slices of a human brain ( 0.75 × 0.75 × 5 mm 3 ) or 3 slices of the abdomen ( 1.25 × 1.25 × 6 mm 3 ) within 4 seconds. CONCLUSIONS The IR SMS radial FLASH acquisition together with a nonlinear model-based reconstruction enable rapid high-resolution multi-slice T 1 mapping with good accuracy, precision, and repeatability.
Collapse
Affiliation(s)
- Xiaoqing Wang
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
| | - Sebastian Rosenzweig
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
| | - Nick Scholand
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
| | - H. Christian M. Holme
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
| | - Martin Uecker
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Germany
- Campus Institute Data Science (CIDAS), University of Göttingen, Germany
| |
Collapse
|
14
|
Prospective pediatric study comparing glomerular filtration rate estimates based on motion-robust dynamic contrast-enhanced magnetic resonance imaging and serum creatinine (eGFR) to 99mTc DTPA. Pediatr Radiol 2020; 50:698-705. [PMID: 31984436 PMCID: PMC7153988 DOI: 10.1007/s00247-020-04617-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 12/12/2019] [Accepted: 01/10/2020] [Indexed: 10/25/2022]
Abstract
BACKGROUND Current methods to estimate glomerular filtration rate (GFR) have shortcomings. Estimates based on serum creatinine are known to be inaccurate in the chronically ill and during acute changes in renal function. Gold standard methods such as inulin and 99mTc diethylenetriamine pentaacetic acid (DTPA) require blood or urine sampling and thus can be difficult to perform in children. Motion-robust radial volumetric interpolated breath-hold examination (VIBE) dynamic contrast-enhanced MRI represents a novel tool for estimating GFR that has not been validated in children. OBJECTIVE The purpose of our study was to determine the feasibility and accuracy of GFR measured by motion-robust radial VIBE dynamic contrast-enhanced MRI compared to estimates by serum creatinine (eGFR) and 99mTc DTPA in children. MATERIALS AND METHODS We enrolled children, 0-18 years of age, who were undergoing both a contrast-enhanced MRI and nuclear medicine 99mTc DTPA glomerular filtration rate (NM-GFR) within 2 weeks of each other. Enrolled children consented to an additional 6-min dynamic contrast-enhanced MRI scan using the motion-robust high spatiotemporal resolution prototype dynamic radial VIBE sequence (Siemens, Erlangen, Germany) at 3 tesla (T). The images were reconstructed offline with high temporal resolution (~3 s/volume) using compressed sensing image reconstruction including regularization in temporal dimension to improve image quality and reduce streaking artifacts. Images were then automatically post-processed using in-house-developed software. Post-processing steps included automatic segmentation of kidney parenchyma and aorta using convolutional neural network techniques and tracer kinetic model fitting using the Sourbron two-compartment model to calculate the MR-based GFR (MR-GFR). The NM-GFR was compared to MR-GFR and estimated GFR based on serum creatinine (eGFR) using Pearson correlation coefficient and Bland-Altman analysis. RESULTS Twenty-one children (7 female, 14 male) were enrolled between February 2017 and May 2018. Data from six of these children were not further analyzed because of deviations from the MRI protocol. Fifteen patients were analyzed (5 female, 10 male; average age 5.9 years); the method was technically feasible in all children. The results showed that the MR-GFR correlated with NM-GFR with a Pearson correlation coefficient (r-value) of 0.98. Bland-Altman analysis (i.e. difference of MR-GFR and NM-GFR versus mean of NM-GFR and MR-GFR) showed a mean difference of -0.32 and reproducibility coefficient of 18 with 95% confidence interval, and the coefficient of variation of 6.7% with values between -19 (-1.96 standard deviation) and 18 (+1.96 standard deviation). In contrast, serum creatinine compared with NM-GFR yielded an r-value of 0.73. Bland-Altman analysis (i.e. difference of eGFR and NM-GFR versus mean of NM-GFR and eGFR) showed a mean difference of 2.9 and reproducibility coefficient of 70 with 95% confidence interval, and the coefficient of variation of 25% with values between -67 (-1.96 standard deviation) and 73 (+1.96 standard deviation). CONCLUSION MR-GFR is a technically feasible and reliable method of measuring GFR when compared to the reference standard, NM-GFR by serum 99mTc DTPA, and MR-GFR is more reliable than estimates based on serum creatinine.
Collapse
|
15
|
Wolf M, de Boer A, Sharma K, Boor P, Leiner T, Sunder-Plassmann G, Moser E, Caroli A, Jerome NP. Magnetic resonance imaging T1- and T2-mapping to assess renal structure and function: a systematic review and statement paper. Nephrol Dial Transplant 2019; 33:ii41-ii50. [PMID: 30137583 PMCID: PMC6106643 DOI: 10.1093/ndt/gfy198] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 05/29/2018] [Indexed: 12/18/2022] Open
Abstract
This systematic review, initiated by the European Cooperation in Science and Technology Action Magnetic Resonance Imaging Biomarkers for Chronic Kidney Disease (PARENCHIMA), focuses on potential clinical applications of magnetic resonance imaging in renal non-tumour disease using magnetic resonance relaxometry (MRR), specifically, the measurement of the independent quantitative magnetic resonance relaxation times T1 and T2 at 1.5 and 3Tesla (T), respectively. Healthy subjects show a distinguishable cortico-medullary differentiation (CMD) in T1 and a slight CMD in T2. Increased cortical T1 values, that is, reduced T1 CMD, were reported in acute allograft rejection (AAR) and diminished T1 CMD in chronic allograft rejection. However, ambiguous findings were reported and AAR could not be sufficiently differentiated from acute tubular necrosis and cyclosporine nephrotoxicity. Despite this, one recent quantitative study showed in renal transplants a direct correlation between fibrosis and T1 CMD. Additionally, various renal diseases, including renal transplants, showed a moderate to strong correlation between T1 CMD and renal function. Recent T2 studies observed increased values in renal transplants compared with healthy subjects and in early-stage autosomal dominant polycystic kidney disease (ADPKD), which could improve diagnosis and progression assessment compared with total kidney volume alone in early-stage ADPKD. Renal MRR is suggested to be sensitive to renal perfusion, ischaemia/oxygenation, oedema, fibrosis, hydration and comorbidities, which reduce specificity. Due to the lack of standardization in patient preparation, acquisition protocols and adequate patient selection, no widely accepted reference values are currently available. Therefore this review encourages efforts to optimize and standardize (multi-parametric) protocols to increase specificity and to tap the full potential of renal MRR in future research.
Collapse
Affiliation(s)
- Marcos Wolf
- Center for Medical Physics and Biomedical Engineering, MR-Centre of Excellence, Medical University of Vienna, Vienna, Austria
| | - Anneloes de Boer
- Department of Radiology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Kanishka Sharma
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Peter Boor
- Institute of Pathology & Division of Nephrology, RWTH University of Aachen, Aachen, Germany
| | - Tim Leiner
- Department of Radiology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Gere Sunder-Plassmann
- Department of Medicine III, Division of Nephrology and Dialysis, General Hospital and Medical University of Vienna, Vienna, Austria
| | - Ewald Moser
- Center for Medical Physics and Biomedical Engineering, MR-Centre of Excellence, Medical University of Vienna, Vienna, Austria
| | - Anna Caroli
- Medical Imaging Unit, Bioengineering Department, IRCCS Istituto di Ricerche Farmacologiche Mario Negri, Bergamo, Italy
| | - Neil Peter Jerome
- Clinic of Radiology and Nuclear Medicine, St. Olavs University Hospital, Trondheim, Norway.,Department of Circulation and Medical Imaging, NTNU - Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
16
|
Tirkes T, Mitchell JR, Li L, Zhao X, Lin C. Normal T 1 relaxometry and extracellular volume of the pancreas in subjects with no pancreas disease: correlation with age and gender. Abdom Radiol (NY) 2019; 44:3133-3138. [PMID: 31139885 DOI: 10.1007/s00261-019-02071-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE Determine normal T1 and extracellular volume (ECV) of the pancreas in subjects with no pancreas disease and correlate with age and gender. SUBJECTS AND METHODS We imaged 120 healthy subjects (age range 20-78 years) who are on annual screening with MRI/MRCP for the possibility of pancreatic cancer. Subjects had a predisposition to develop pancreatic cancer, but no history of pancreas disease or acute symptoms. Equal number (n = 60) of subjects were scanned on either 1.5 T or 3 T scanner using dual flip angle spoiled gradient echo technique incorporating fat suppression and correction for B1 field inhomogeneity. Optimization of imaging parameters was performed using a T1 phantom. ECV was calculated using pre- and post-contrast T1 of the pancreas and plasma. Regression analysis and Mann-Whitney tests were used for statistical analysis. RESULTS Median T1 on 1.5 T was 654 ms (IQR 608-700); median T1 on 3 T was 717 ms (IQR 582-850); median ECV on 1.5 T was 0.28 (IQR 0.21-0.33), and median ECV on 3 T was 0.25 (IQR 0.19-0.28). Age had a mild positive correlation with T1 (r = 0.24, p = 0.009), but not with ECV (r = 0.06, p = 0.54). T1 and ECV were similar in both genders (p > 0.05). CONCLUSION This study measured the median T1 and ECV of the pancreas in subjects with no pancreas disease. Pancreas shows longer T1 relaxation times in older population, whereas extracellular fraction remains unchanged. Median T1 values were different between two magnet strengths; however, no difference was seen between genders and ECV fractions.
Collapse
Affiliation(s)
- Temel Tirkes
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, 550 N. University Blvd. Suite 0663, Indianapolis, IN, 46202, USA.
| | - Jacob R Mitchell
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, 550 N. University Blvd. Suite 0663, Indianapolis, IN, 46202, USA
| | - Liang Li
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1411, FCT4.6008, Houston, TX, 77030, USA
| | - Xuandong Zhao
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, R2 E124G, 950 W Walnut Street, Indianapolis, IN, 46202, USA
| | - Chen Lin
- Department of Radiology, Mayo Clinic, 4500 San Pablo Rd, Jacksonville, FL, 32224, USA
| |
Collapse
|
17
|
Obmann VC, Mertineit N, Marx C, Berzigotti A, Ebner L, Heverhagen JT, Christe A, Huber AT. Liver MR relaxometry at 3T - segmental normal T 1 and T 2* values in patients without focal or diffuse liver disease and in patients with increased liver fat and elevated liver stiffness. Sci Rep 2019; 9:8106. [PMID: 31147588 PMCID: PMC6542826 DOI: 10.1038/s41598-019-44377-y] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 05/10/2019] [Indexed: 02/07/2023] Open
Abstract
Magnetic resonance (MR) T1 and T2* mapping allows quantification of liver relaxation times for non-invasive characterization of diffuse liver disease. We hypothesized that liver relaxation times are not only influenced by liver fibrosis, inflammation and fat, but also by air in liver segments adjacent to the lung – especially in MR imaging at 3T. A total of 161 study participants were recruited, while 6 patients had to be excluded due to claustrophobia or technically uninterpretable MR elastography. Resulting study population consisted of 12 healthy volunteers and 143 patients who prospectively underwent multiparametric MR imaging at 3T. Of those 143 patients, 79 had normal liver stiffness in MR elastography (shear modulus <2.8 kPa, indicating absence of fibrosis) and normal proton density fat fraction (PDFF < 10%, indicating absence of steatosis), defined as reference population. T1 relaxation times in these patients were significantly shorter in liver segments adjacent to the lung than in those not adjacent to the lung (p < 0.001, mean of differences 33 ms). In liver segments not adjacent to the lung, T1 allowed to differentiate significantly between the reference population and patients with steatosis and/or fibrosis (p ≤ 0.011), while there was no significant difference of T1 between the reference population and healthy volunteers. In conclusion, we propose to measure T1 relaxation times in liver segments not adjacent to the lung. Otherwise, we recommend taking into account slightly shorter T1 values in liver segments adjacent to the lung.
Collapse
Affiliation(s)
- V C Obmann
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - N Mertineit
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - C Marx
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - A Berzigotti
- Hepatology, Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, INO A, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - L Ebner
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - J T Heverhagen
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - A Christe
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland
| | - A T Huber
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, INO B, Freiburgstrasse 10, 3010, Bern, Switzerland.
| |
Collapse
|
18
|
Lo WC, Chen Y, Jiang Y, Hamilton J, Grimm R, Griswold M, Gulani V, Seiberlich N. Realistic 4D MRI abdominal phantom for the evaluation and comparison of acquisition and reconstruction techniques. Magn Reson Med 2018; 81:1863-1875. [PMID: 30394573 DOI: 10.1002/mrm.27545] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 07/24/2018] [Accepted: 08/30/2018] [Indexed: 12/22/2022]
Abstract
PURPOSE This work presents a 4D numerical abdominal phantom, which includes T1 and T2 relaxation times, proton density fat fraction, perfusion, and diffusion, as well as respiratory motion for the evaluation and comparison of acquisition and reconstruction techniques. METHODS The 3D anatomical mesh models were non-rigidly scaled and shifted by respiratory motion derived from an in vivo scan. A time series of voxelized 3D abdominal phantom images were obtained with contrast determined by the tissue properties and pulse sequence parameters. Two example simulations: (1) 3D T1 mapping under breath-hold and free-breathing acquisition conditions and (2) two different reconstruction techniques for accelerated 3D dynamic contrast-enhanced MRI, are presented. The source codes can be found at https://github.com/SeiberlichLab/Abdominal_MR_Phantom. RESULTS The proposed 4D abdominal phantom can successfully simulate images and MRI data with nonrigid respiratory motion and specific contrast settings and data sampling schemes. In example 1, the use of a numerical 4D abdominal phantom was demonstrated to aid in the comparison between different approaches for volumetric T1 mapping. In example 2, the average arterial fraction over the healthy hepatic parenchyma as calculated with spiral generalized autocalibrating partial parallel acquisition was closer to that from the fully sampled data than the arterial fraction from conjugate gradient sensitivity encoding, although both are elevated compared to the gold-standard reference. CONCLUSION This realistic abdominal MR phantom can be used to simulate different pulse sequences and data sampling schemes for the comparison of acquisition and reconstruction methods under controlled conditions that are impossible or prohibitively difficult to perform in vivo.
Collapse
Affiliation(s)
- Wei-Ching Lo
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio
| | - Yong Chen
- Department of Radiology, UH Cleveland Medical Center, Cleveland, Ohio
| | - Yun Jiang
- Department of Radiology, UH Cleveland Medical Center, Cleveland, Ohio
| | - Jesse Hamilton
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio
| | | | - Mark Griswold
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.,Department of Radiology, UH Cleveland Medical Center, Cleveland, Ohio
| | - Vikas Gulani
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.,Department of Radiology, UH Cleveland Medical Center, Cleveland, Ohio
| | - Nicole Seiberlich
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.,Department of Radiology, UH Cleveland Medical Center, Cleveland, Ohio
| |
Collapse
|
19
|
Zhou L, Tang L, Yang T, Chen W. Comparison of contrast-enhanced ultrasound with MRI in the diagnosis of complex cystic renal masses: a meta-analysis. Acta Radiol 2018; 59:1254-1263. [PMID: 29363321 DOI: 10.1177/0284185118755575] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Background The differential diagnosis of cystic renal masses still faces great challenges. There has been no systematically assessment to compare the value of contrast-enhanced ultrasound (CEUS) with magnetic resonance imaging (MRI) in the diagnosis of cystic renal masses. Purpose To perform a meta-analysis to compare the diagnostic efficacy of CEUS with that of MRI for cystic renal masses. Material and Methods A systematic search was performed for literature evaluating the diagnostic performance of CEUS or MRI in cystic renal masses. Quality assessment of diagnostic studies 2 (QUADAS-2) was used to evaluate the quality of each study included. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and the areas under the summary receiver operating characteristic (AUCs-SROC) curve for CEUS and MRI were calculated, respectively. Results Seventeen studies with 1142 lesions were included. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio for CEUS /MRI were 0.95/0.92, 0.84/0.91, 5.62/6.74, and 0.09/0.13, respectively. The AUCs-SROC curves for the two methods were 95.66% and 94.65%. The subgroup analysis indicated that the scanning slice thickness may influence the diagnostic efficacy of MRI. Conclusion Both CEUS and MRI have good diagnostic performance for cystic renal masses and can provide the reference for clinicians. CEUS is more sensitive but less specific than MRI.
Collapse
Affiliation(s)
- Linli Zhou
- Department of Radiology, School of Medicine, Nantong University, Nantong, Jiangsu, PR China
| | - Lemin Tang
- Department of Radiology, School of Medicine, Nantong University, Nantong, Jiangsu, PR China
| | - Tao Yang
- Department of Radiology, School of Medicine, Nantong University, Nantong, Jiangsu, PR China
| | - Wei Chen
- Department of Radiology, School of Medicine, Nantong University, Nantong, Jiangsu, PR China
| |
Collapse
|
20
|
Fast Interleaved Multislice T1 Mapping: Model-Based Reconstruction of Single-Shot Inversion-Recovery Radial FLASH. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2018; 2018:2560964. [PMID: 30186361 PMCID: PMC6110002 DOI: 10.1155/2018/2560964] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 07/18/2018] [Indexed: 12/20/2022]
Abstract
Purpose To develop a high-speed multislice T1 mapping method based on a single-shot inversion-recovery (IR) radial FLASH acquisition and a regularized model-based reconstruction. Methods Multislice radial k-space data are continuously acquired after a single nonselective inversion pulse using a golden-angle sampling scheme in a spoke-interleaved manner with optimized flip angles. Parameter maps and coil sensitivities of each slice are estimated directly from highly undersampled radial k-space data using a model-based nonlinear inverse reconstruction in conjunction with joint sparsity constraints. The performance of the method has been validated using a numerical and experimental T1 phantom as well as demonstrated for studies of the human brain and liver at 3T. Results The proposed method allows for 7 simultaneous T1 maps of the brain at 0.5 × 0.5 × 4 mm3 resolution within a single IR experiment of 4 s duration. Phantom studies confirm similar accuracy and precision as obtained for a single-slice acquisition. For abdominal applications, the proposed method yields three simultaneous T1 maps at 1.25 × 1.25 × 6 mm3 resolution within a 4 s breath hold. Conclusion Rapid, robust, accurate, and precise multislice T1 mapping may be achieved by combining the advantages of a model-based nonlinear inverse reconstruction, radial sampling, parallel imaging, and compressed sensing.
Collapse
|
21
|
Chen Y, Lo WC, Hamilton JI, Barkauskas K, Saybasili H, Wright KL, Batesole J, Griswold MA, Gulani V, Seiberlich N. Single breath-hold 3D cardiac T 1 mapping using through-time spiral GRAPPA. NMR IN BIOMEDICINE 2018; 31:e3923. [PMID: 29637637 PMCID: PMC5980781 DOI: 10.1002/nbm.3923] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 02/26/2018] [Accepted: 02/27/2018] [Indexed: 06/08/2023]
Abstract
The quantification of cardiac T1 relaxation time holds great potential for the detection of various cardiac diseases. However, as a result of both cardiac and respiratory motion, only one two-dimensional T1 map can be acquired in one breath-hold with most current techniques, which limits its application for whole heart evaluation in routine clinical practice. In this study, an electrocardiogram (ECG)-triggered three-dimensional Look-Locker method was developed for cardiac T1 measurement. Fast three-dimensional data acquisition was achieved with a spoiled gradient-echo sequence in combination with a stack-of-spirals trajectory and through-time non-Cartesian generalized autocalibrating partially parallel acquisition (GRAPPA) acceleration. The effects of different magnetic resonance parameters on T1 quantification with the proposed technique were first examined by simulating data acquisition and T1 map reconstruction using Bloch equation simulations. Accuracy was evaluated in studies with both phantoms and healthy subjects. These results showed that there was close agreement between the proposed technique and the reference method for a large range of T1 values in phantom experiments. In vivo studies further demonstrated that rapid cardiac T1 mapping for 12 three-dimensional partitions (spatial resolution, 2 × 2 × 8 mm3 ) could be achieved in a single breath-hold of ~12 s. The mean T1 values of myocardial tissue and blood obtained from normal volunteers at 3 T were 1311 ± 66 and 1890 ± 159 ms, respectively. In conclusion, a three-dimensional T1 mapping technique was developed using a non-Cartesian parallel imaging method, which enables fast and accurate T1 mapping of cardiac tissues in a single short breath-hold.
Collapse
Affiliation(s)
- Yong Chen
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Wei-Ching Lo
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Jesse I Hamilton
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Kestutis Barkauskas
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | | | - Katherine L Wright
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Joshua Batesole
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Mark A Griswold
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Vikas Gulani
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Nicole Seiberlich
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
22
|
Kobayashi Y, Terada Y. Diffusion-weighting Caused by Spoiler Gradients in the Fast Imaging with Steady-state Precession Sequence May Lead to Inaccurate T 2 Measurements in MR Fingerprinting. Magn Reson Med Sci 2018; 18:96-104. [PMID: 29794408 PMCID: PMC6326765 DOI: 10.2463/mrms.tn.2018-0027] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Magnetic resonance fingerprinting (MRF) is a promising framework that allows the quantification of multiple magnetic resonance parameters with a single scan. MRF using fast imaging with steady-state precession (MRF-FISP) has robustness to off-resonance artifacts and has many applications in inhomogeneous fields. However, the spoiler gradient used in MRF-FISP is sensitive to diffusion motion, and may lead to quantification errors when the spoiler moment increases. In this study, we examined the effect of the diffusion weighting in MRF-FISP caused by spoiler gradients. The T2 relaxation times were greatly underestimated when large spoiler moments were used. The T2 underestimation was prominent for tissues with large values of T2 and diffusion coefficients. The T2 bias was almost independent of the apparent diffusion coefficient (ADC) and T2 values when the ADC map was measured and incorporated into the matching process. These results reveal that the T2 underestimation resulted from the diffusion weighting caused by the spoiler gradients.
Collapse
|
23
|
Single-breath-hold abdominal [Formula: see text] mapping using 3D Cartesian Look-Locker with spatiotemporal sparsity constraints. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2018; 31:399-414. [PMID: 29372469 DOI: 10.1007/s10334-017-0670-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 11/24/2017] [Accepted: 12/19/2017] [Indexed: 10/18/2022]
Abstract
OBJECTIVE Our aim was to develop and validate a 3D Cartesian Look-Locker [Formula: see text] mapping technique that achieves high accuracy and whole-liver coverage within a single breath-hold. MATERIALS AND METHODS The proposed method combines sparse Cartesian sampling based on a spatiotemporally incoherent Poisson pattern and k-space segmentation, dedicated for high-temporal-resolution imaging. This combination allows capturing tissue with short relaxation times with volumetric coverage. A joint reconstruction of the 3D + inversion time (TI) data via compressed sensing exploits the spatiotemporal sparsity and ensures consistent quality for the subsequent multistep [Formula: see text] mapping. Data from the National Institute of Standards and Technology (NIST) phantom and 11 volunteers, along with reference 2D Look-Locker acquisitions, are used for validation. 2D and 3D methods are compared based on [Formula: see text] values in different abdominal tissues at 1.5 and 3 T. RESULTS [Formula: see text] maps obtained from the proposed 3D method compare favorably with those from the 2D reference and additionally allow for reformatting or volumetric analysis. Excellent agreement is shown in phantom [bias[Formula: see text] < 2%, bias[Formula: see text] < 5% for (120; 2000) ms] and volunteer data (3D and 2D deviation < 4% for liver, muscle, and spleen) for clinically acceptable scan (20 s) and reconstruction times (< 4 min). CONCLUSION Whole-liver [Formula: see text] mapping with high accuracy and precision is feasible in one breath-hold using spatiotemporally incoherent, sparse 3D Cartesian sampling.
Collapse
|
24
|
Hamilton J, Franson D, Seiberlich N. Recent advances in parallel imaging for MRI. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2017; 101:71-95. [PMID: 28844222 PMCID: PMC5927614 DOI: 10.1016/j.pnmrs.2017.04.002] [Citation(s) in RCA: 106] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 04/09/2017] [Accepted: 04/17/2017] [Indexed: 05/22/2023]
Abstract
Magnetic Resonance Imaging (MRI) is an essential technology in modern medicine. However, one of its main drawbacks is the long scan time needed to localize the MR signal in space to generate an image. This review article summarizes some basic principles and recent developments in parallel imaging, a class of image reconstruction techniques for shortening scan time. First, the fundamentals of MRI data acquisition are covered, including the concepts of k-space, undersampling, and aliasing. It is demonstrated that scan time can be reduced by sampling a smaller number of phase encoding lines in k-space; however, without further processing, the resulting images will be degraded by aliasing artifacts. Nearly all modern clinical scanners acquire data from multiple independent receiver coil arrays. Parallel imaging methods exploit properties of these coil arrays to separate aliased pixels in the image domain or to estimate missing k-space data using knowledge of nearby acquired k-space points. Three parallel imaging methods-SENSE, GRAPPA, and SPIRiT-are described in detail, since they are employed clinically and form the foundation for more advanced methods. These techniques can be extended to non-Cartesian sampling patterns, where the collected k-space points do not fall on a rectangular grid. Non-Cartesian acquisitions have several beneficial properties, the most important being the appearance of incoherent aliasing artifacts. Recent advances in simultaneous multi-slice imaging are presented next, which use parallel imaging to disentangle images of several slices that have been acquired at once. Parallel imaging can also be employed to accelerate 3D MRI, in which a contiguous volume is scanned rather than sequential slices. Another class of phase-constrained parallel imaging methods takes advantage of both image magnitude and phase to achieve better reconstruction performance. Finally, some applications are presented of parallel imaging being used to accelerate MR Spectroscopic Imaging.
Collapse
Affiliation(s)
- Jesse Hamilton
- Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
| | - Dominique Franson
- Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
| | - Nicole Seiberlich
- Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA; Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.
| |
Collapse
|
25
|
Lingala SG, Zhu Y, Lim Y, Toutios A, Ji Y, Lo WC, Seiberlich N, Narayanan S, Nayak KS. Feasibility of through-time spiral generalized autocalibrating partial parallel acquisition for low latency accelerated real-time MRI of speech. Magn Reson Med 2017; 78:2275-2282. [PMID: 28185301 DOI: 10.1002/mrm.26611] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 12/08/2016] [Accepted: 12/27/2016] [Indexed: 12/11/2022]
Abstract
PURPOSE To evaluate the feasibility of through-time spiral generalized autocalibrating partial parallel acquisition (GRAPPA) for low-latency accelerated real-time MRI of speech. METHODS Through-time spiral GRAPPA (spiral GRAPPA), a fast linear reconstruction method, is applied to spiral (k-t) data acquired from an eight-channel custom upper-airway coil. Fully sampled data were retrospectively down-sampled to evaluate spiral GRAPPA at undersampling factors R = 2 to 6. Pseudo-golden-angle spiral acquisitions were used for prospective studies. Three subjects were imaged while performing a range of speech tasks that involved rapid articulator movements, including fluent speech and beat-boxing. Spiral GRAPPA was compared with view sharing, and a parallel imaging and compressed sensing (PI-CS) method. RESULTS Spiral GRAPPA captured spatiotemporal dynamics of vocal tract articulators at undersampling factors ≤4. Spiral GRAPPA at 18 ms/frame and 2.4 mm2 /pixel outperformed view sharing in depicting rapidly moving articulators. Spiral GRAPPA and PI-CS provided equivalent temporal fidelity. Reconstruction latency per frame was 14 ms for view sharing and 116 ms for spiral GRAPPA, using a single processor. Spiral GRAPPA kept up with the MRI data rate of 18ms/frame with eight processors. PI-CS required 17 minutes to reconstruct 5 seconds of dynamic data. CONCLUSION Spiral GRAPPA enabled 4-fold accelerated real-time MRI of speech with a low reconstruction latency. This approach is applicable to wide range of speech RT-MRI experiments that benefit from real-time feedback while visualizing rapid articulator movement. Magn Reson Med 78:2275-2282, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Sajan Goud Lingala
- Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, California, USA
| | - Yinghua Zhu
- Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, California, USA
| | - Yongwan Lim
- Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, California, USA
| | - Asterios Toutios
- Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, California, USA
| | - Yunhua Ji
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA
| | - Wei-Ching Lo
- Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Nicole Seiberlich
- Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Shrikanth Narayanan
- Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, California, USA
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
26
|
Chen Y, Jiang Y, Pahwa S, Ma D, Lu L, Twieg MD, Wright KL, Seiberlich N, Griswold MA, Gulani V. MR Fingerprinting for Rapid Quantitative Abdominal Imaging. Radiology 2016; 279:278-86. [PMID: 26794935 DOI: 10.1148/radiol.2016152037] [Citation(s) in RCA: 154] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE To develop a magnetic resonance (MR) "fingerprinting" technique for quantitative abdominal imaging. MATERIALS AND METHODS This HIPAA-compliant study had institutional review board approval, and informed consent was obtained from all subjects. To achieve accurate quantification in the presence of marked B0 and B1 field inhomogeneities, the MR fingerprinting framework was extended by using a two-dimensional fast imaging with steady-state free precession, or FISP, acquisition and a Bloch-Siegert B1 mapping method. The accuracy of the proposed technique was validated by using agarose phantoms. Quantitative measurements were performed in eight asymptomatic subjects and in six patients with 20 focal liver lesions. A two-tailed Student t test was used to compare the T1 and T2 results in metastatic adenocarcinoma with those in surrounding liver parenchyma and healthy subjects. RESULTS Phantom experiments showed good agreement with standard methods in T1 and T2 after B1 correction. In vivo studies demonstrated that quantitative T1, T2, and B1 maps can be acquired within a breath hold of approximately 19 seconds. T1 and T2 measurements were compatible with those in the literature. Representative values included the following: liver, 745 msec ± 65 (standard deviation) and 31 msec ± 6; renal medulla, 1702 msec ± 205 and 60 msec ± 21; renal cortex, 1314 msec ± 77 and 47 msec ± 10; spleen, 1232 msec ± 92 and 60 msec ± 19; skeletal muscle, 1100 msec ± 59 and 44 msec ± 9; and fat, 253 msec ± 42 and 77 msec ± 16, respectively. T1 and T2 in metastatic adenocarcinoma were 1673 msec ± 331 and 43 msec ± 13, respectively, significantly different from surrounding liver parenchyma relaxation times of 840 msec ± 113 and 28 msec ± 3 (P < .0001 and P < .01) and those in hepatic parenchyma in healthy volunteers (745 msec ± 65 and 31 msec ± 6, P < .0001 and P = .021, respectively). CONCLUSION A rapid technique for quantitative abdominal imaging was developed that allows simultaneous quantification of multiple tissue properties within one 19-second breath hold, with measurements comparable to those in published literature.
Collapse
Affiliation(s)
- Yong Chen
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Yun Jiang
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Shivani Pahwa
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Dan Ma
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Lan Lu
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Michael D Twieg
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Katherine L Wright
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Nicole Seiberlich
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Mark A Griswold
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| | - Vikas Gulani
- From the Departments of Radiology (Y.C., S.P., D.M., L.L., K.L.W., M.A.G., V.G.), Biomedical Engineering (Y.J., N.S., M.A.G.), and Electrical Engineering and Computer Science (M.D.T.), Case Western Reserve University/University Hospitals Case Medical Center, 11100 Euclid Ave, Bolwell Building, Room B120, Cleveland, OH 44106
| |
Collapse
|