Zhao B, Zhou Y, Zong X. Effects of prospective motion correction on perivascular spaces at 7T MRI evaluated using motion artifact simulation. Magn Reson Med 2024; 92:1079-1094. [PMID: 38651650 PMCID: PMC11209793 DOI: 10.1002/mrm.30126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 03/12/2024] [Accepted: 04/04/2024] [Indexed: 04/25/2024]
Abstract
PURPOSE The effectiveness of prospective motion correction (PMC) is often evaluated by comparing artifacts in images acquired with and without PMC (NoPMC). However, such an approach is not applicable in clinical setting due to unavailability of NoPMC images. We aim to develop a simulation approach for demonstrating the ability of fat-navigator-based PMC in improving perivascular space (PVS) visibility in T2-weighted MRI. METHODS MRI datasets from two earlier studies were used for motion artifact simulation and evaluating PMC, including T2-weighted NoPMC and PMC images. To simulate motion artifacts, k-space data at motion-perturbed positions were calculated from artifact-free images using nonuniform Fourier transform and misplaced onto the Cartesian grid before inverse Fourier transform. The simulation's ability to reproduce motion-induced blurring, ringing, and ghosting artifacts was evaluated using sharpness at lateral ventricle/white matter boundary, ringing artifact magnitude in the Fourier spectrum, and background noise, respectively. PVS volume fraction in white matter was employed to reflect its visibility. RESULTS In simulation, sharpness, PVS volume fraction, and background noise exhibited significant negative correlations with motion score. Significant correlations were found in sharpness, ringing artifact magnitude, and PVS volume fraction between simulated and real NoPMC images (p ≤ 0.006). In contrast, such correlations were reduced and nonsignificant between simulated and real PMC images (p ≥ 0.48), suggesting reduction of motion effects with PMC. CONCLUSIONS The proposed simulation approach is an effective tool to study the effects of motion and PMC on PVS visibility. PMC may reduce the systematic bias of PVS volume fraction caused by motion artifacts.
Collapse
Affiliation(s)
- Bingbing Zhao
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| | - Yichen Zhou
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| | - Xiaopeng Zong
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China
| |
Collapse
|
2
|
Visualisation of lenticulostriate arteries using contrast-enhanced time-of-flight magnetic resonance angiography at 7 Tesla. Sci Rep 2022; 12:20306. [PMID: 36434036 PMCID: PMC9700841 DOI: 10.1038/s41598-022-24832-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Accepted: 11/21/2022] [Indexed: 11/27/2022] Open
Abstract
7 Tesla-field-strength (7 T) Magnetic Resonance Imaging allows the small perforating arteries in the brain to be visualised, and this modality may allow visualisation of the arterial pathology in cerebral small vessel disease. Most studies have used standard Time-of-Flight (ToF) Magnetic Resonance Angiography (MRA). Whether the use of contrast enhancement improves perforating artery visualisation at 7 T remains unclear. In a prospective study, we compared standard ToF MRA with contrast-enhanced (CE) ToF MRA at 7 T for the visualisation of the lenticulostriate arteries (LSAs). Ten patients with symptomatic lacunar stroke were recruited (mean age, SD, 64 ± 9.9 years). Visualisation was assessed using a visual rating scale administered by two independent expert readers and length of the LSAs visible. Visualisation of the LSAs was improved with CE ToF MRA. The mean Visibility and Sharpness Score was higher for CE ToF MRA over standard ToF MRA (2.55 ± 0.64 vs. 1.75 ± 0.68; P = 0.0008). The mean length of LSA visualised was significantly longer with CE ToF MRA compared to standard ToF MRA (24.4 ± 4.5 vs. 21.9 ± 4.0 mm; P = 0.01). CE ToF MRA offers improved visualisation of the LSAs over standard ToF MRA. The addition of contrast may improve the ability to visualise cerebral small vessel disease arterial pathology.
Collapse
|
3
|
Slipsager JM, Glimberg SL, Højgaard L, Paulsen RR, Wighton P, Tisdall MD, Jaimes C, Gagoski BA, Grant PE, van der Kouwe A, Olesen OV, Frost R. Comparison of prospective and retrospective motion correction in 3D-encoded neuroanatomical MRI. Magn Reson Med 2022; 87:629-645. [PMID: 34490929 PMCID: PMC8635810 DOI: 10.1002/mrm.28991] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 07/17/2021] [Accepted: 08/10/2021] [Indexed: 02/03/2023]
Abstract
PURPOSE To compare prospective motion correction (PMC) and retrospective motion correction (RMC) in Cartesian 3D-encoded MPRAGE scans and to investigate the effects of correction frequency and parallel imaging on the performance of RMC. METHODS Head motion was estimated using a markerless tracking system and sent to a modified MPRAGE sequence, which can continuously update the imaging FOV to perform PMC. The prospective correction was applied either before each echo train (before-ET) or at every sixth readout within the ET (within-ET). RMC was applied during image reconstruction by adjusting k-space trajectories according to the measured motion. The motion correction frequency was retrospectively increased with RMC or decreased with reverse RMC. Phantom and in vivo experiments were used to compare PMC and RMC, as well as to compare within-ET and before-ET correction frequency during continuous motion. The correction quality was quantitatively evaluated using the structural similarity index measure with a reference image without motion correction and without intentional motion. RESULTS PMC resulted in superior image quality compared to RMC both visually and quantitatively. Increasing the correction frequency from before-ET to within-ET reduced the motion artifacts in RMC. A hybrid PMC and RMC correction, that is, retrospectively increasing the correction frequency of before-ET PMC to within-ET, also reduced motion artifacts. Inferior performance of RMC compared to PMC was shown with GRAPPA calibration data without intentional motion and without any GRAPPA acceleration. CONCLUSION Reductions in local Nyquist violations with PMC resulted in superior image quality compared to RMC. Increasing the motion correction frequency to within-ET reduced the motion artifacts in both RMC and PMC.
Collapse
Affiliation(s)
- Jakob M. Slipsager
- DTU Compute, Technical University of Denmark, Denmark
- Dept. of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Denmark
- TracInnovations, Ballerup, Denmark
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
| | | | - Liselotte Højgaard
- Dept. of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Denmark
| | | | - Paul Wighton
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
| | - M. Dylan Tisdall
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Camilo Jaimes
- Boston Children’s Hospital, Boston, Massachusetts
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
| | - Borjan A. Gagoski
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children’s Hospital, Boston, Massachusetts
| | - P. Ellen Grant
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children’s Hospital, Boston, Massachusetts
| | - André van der Kouwe
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
| | - Oline V. Olesen
- DTU Compute, Technical University of Denmark, Denmark
- Dept. of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, University of Copenhagen, Denmark
- TracInnovations, Ballerup, Denmark
| | - Robert Frost
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts
- Dept. of Radiology, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
4
|
Hucker P, Dacko M, Zaitsev M. Combining prospective and retrospective motion correction based on a model for fast continuous motion. Magn Reson Med 2021; 86:1284-1298. [PMID: 33829538 DOI: 10.1002/mrm.28783] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 03/05/2021] [Accepted: 03/06/2021] [Indexed: 11/08/2022]
Abstract
PURPOSE Prospective motion correction (PMC) and retrospective motion correction (RMC) have different advantages and limitations. The present work aims to combine the advantages of both for rigid body motion, aiming at correcting for faster motions than was previously achievable. Additionally, it provides insights into the effects of motion on pulse sequences and MR signals with a goal of further improving motion correction in the future. METHODS The effective encoding trajectory and a global phase offset in a moving object are calculated based on complete gradient waveforms of an arbitrary sequence and a continuous motion model. These data are used to feed the forward signal model, which is then used in iterative image reconstruction to suppress the artifacts still present after the PMC. RESULTS Verification experiments with a rotation phantom and in vivo were performed. Predictions of simulated motion artifacts for PMC based on sequence waveforms are very accurate. The performance at combined PMC+RMC is limited by Nyquist violations in the sampled k-space and can be compensated by oversampling. CONCLUSION The combined correction results in better images than pure PMC in the presence of fast motion. The predictions of artifacts are very accurate, allowing for comparing sequences or protocols in simulations. The observed artifacts due to Nyquist violations are expected to be corrected by utilizing parallel imaging.
Collapse
Affiliation(s)
- Patrick Hucker
- Center for Diagnostic and Therapeutic Radiology, Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Dacko
- Center for Diagnostic and Therapeutic Radiology, Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Maxim Zaitsev
- Center for Diagnostic and Therapeutic Radiology, Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.,High Field Magnetic Resonance Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
5
|
Parker DB, Spincemaille P, Razlighi QR. Attenuation of motion artifacts in fMRI using discrete reconstruction of irregular fMRI trajectories (DRIFT). Magn Reson Med 2021; 86:1586-1599. [PMID: 33797118 DOI: 10.1002/mrm.28723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 01/16/2021] [Accepted: 01/19/2021] [Indexed: 11/10/2022]
Abstract
PURPOSE Numerous studies report motion as the most detrimental source of noise and artifacts in fMRI. Current motion correction methods fail to completely address the motion problem. Retrospective techniques such as spatial realignment can correct for between-volume misalignment but fail to address within volume contamination and spin-history artifacts. Prospective motion correction can prevent spin-history artifacts but currently cannot update the gradients fast enough to remove k-space filling artifacts, calling for a hybrid approach to fully address these problems. THEORY AND METHODS Motion can be mathematically formulated into the MR signal equation to describe the motion artifacts at their origin in k-space. From these equations, it is demonstrated that different motions have different effects on the signal. A novel motion correction algorithm is designed from these equations to remove motion-induced artifacts directly in k-space, discrete reconstruction of irregular fMRI trajectory (DRIFT). This method is evaluated rigorously using fMRI simulations and data from a rotating phantom inside the scanner. RESULTS The results indicate that although some motion types have negligible effects on the MR signal, others produce catastrophic and lasting artifacts even after motion cessation. In simulation, DRIFT is able to remove motion artifacts in the absence of spin history. In a phantom scan, DRIFT significantly attenuates the motion artifacts in the fMRI data. CONCLUSION Neither prospective nor retrospective motion correction methods could completely remove the motion artifacts from the fMRI data. However, DRIFT, as a retrospective technique, when combined with prospective motion correction, can eliminate a significant portion of motion artifacts.
Collapse
Affiliation(s)
- David B Parker
- Department of Biomedical Engineering, Columbia University, New York City, NY, USA
| | | | | |
Collapse
|
6
|
Bazin PL, Nijsse HE, van der Zwaag W, Gallichan D, Alkemade A, Vos FM, Forstmann BU, Caan MWA. Sharpness in motion corrected quantitative imaging at 7T. Neuroimage 2020; 222:117227. [PMID: 32781231 DOI: 10.1016/j.neuroimage.2020.117227] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 07/03/2020] [Accepted: 07/31/2020] [Indexed: 12/13/2022] Open
Abstract
Sub-millimeter imaging at 7T has opened new possibilities for qualitatively and quantitatively studying brain structure as it evolves throughout the life span. However, subject motion introduces image blurring on the order of magnitude of the spatial resolution and is thus detrimental to image quality. Such motion can be corrected for, but widespread application has not yet been achieved and quantitative evaluation is lacking. This raises a need to quantitatively measure image sharpness throughout the brain. We propose a method to quantify sharpness of brain structures at sub-voxel resolution, and use it to assess to what extent limited motion is related to image sharpness. The method was evaluated in a cohort of 24 healthy volunteers with a wide and uniform age range, aiming to arrive at results that largely generalize to larger populations. Using 3D fat-excited motion navigators, quantitative R1, R2* and Quantitative Susceptibility Maps and T1-weighted images were retrospectively corrected for motion. Sharpness was quantified in all modalities for selected regions of interest (ROI) by fitting the sigmoidally shaped error function to data within locally homogeneous clusters. A strong, almost linear correlation between motion and sharpness improvement was observed, and motion correction significantly improved sharpness. Overall, the Full Width at Half Maximum reduced from 0.88 mm to 0.70 mm after motion correction, equivalent to a 2.0 times smaller voxel volume. Motion and sharpness were not found to correlate with the age of study participants. We conclude that in our data, motion correction using fat navigators is overall able to restore the measured sharpness to the imaging resolution, irrespective of the amount of motion observed during scanning.
Collapse
Affiliation(s)
- Pierre-Louis Bazin
- Integrative Model-based Cognitive Neuroscience research unit, Department of Psychology, University of Amsterdam, Amsterdam, the Netherlands.
| | - Hannah E Nijsse
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands.
| | | | - Daniel Gallichan
- CUBRIC, School of Engineering, Cardiff University, Cardiff, United Kingdom.
| | - Anneke Alkemade
- Integrative Model-based Cognitive Neuroscience research unit, Department of Psychology, University of Amsterdam, Amsterdam, the Netherlands.
| | - Frans M Vos
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands.
| | - Birte U Forstmann
- Integrative Model-based Cognitive Neuroscience research unit, Department of Psychology, University of Amsterdam, Amsterdam, the Netherlands.
| | - Matthan W A Caan
- Amsterdam UMC, University of Amsterdam, Biomedical Engineering and Physics, Amsterdam, the Netherlands.
| |
Collapse
|
7
|
Ladd ME, Bachert P, Meyerspeer M, Moser E, Nagel AM, Norris DG, Schmitter S, Speck O, Straub S, Zaiss M. Pros and cons of ultra-high-field MRI/MRS for human application. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2018; 109:1-50. [PMID: 30527132 DOI: 10.1016/j.pnmrs.2018.06.001] [Citation(s) in RCA: 267] [Impact Index Per Article: 44.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 06/06/2018] [Accepted: 06/07/2018] [Indexed: 05/08/2023]
Abstract
Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.
Collapse
Affiliation(s)
- Mark E Ladd
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Medicine, University of Heidelberg, Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany; Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Peter Bachert
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany.
| | - Martin Meyerspeer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Center of Excellence, Medical University of Vienna, Vienna, Austria.
| | - Ewald Moser
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Center of Excellence, Medical University of Vienna, Vienna, Austria.
| | - Armin M Nagel
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | - David G Norris
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen, Nijmegen, Netherlands; Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Sebastian Schmitter
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany; German Center for Neurodegenerative Diseases, Magdeburg, Germany; Center for Behavioural Brain Sciences, Magdeburg, Germany; Leibniz Institute for Neurobiology, Magdeburg, Germany.
| | - Sina Straub
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
| | - Moritz Zaiss
- High-Field Magnetic Resonance Center, Max-Planck-Institute for Biological Cybernetics, Tübingen, Germany.
| |
Collapse
|
8
|
Oishi K, Chang L, Huang H. Baby brain atlases. Neuroimage 2018; 185:865-880. [PMID: 29625234 DOI: 10.1016/j.neuroimage.2018.04.003] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2017] [Revised: 02/27/2018] [Accepted: 04/02/2018] [Indexed: 01/23/2023] Open
Abstract
The baby brain is constantly changing due to its active neurodevelopment, and research into the baby brain is one of the frontiers in neuroscience. To help guide neuroscientists and clinicians in their investigation of this frontier, maps of the baby brain, which contain a priori knowledge about neurodevelopment and anatomy, are essential. "Brain atlas" in this review refers to a 3D-brain image with a set of reference labels, such as a parcellation map, as the anatomical reference that guides the mapping of the brain. Recent advancements in scanners, sequences, and motion control methodologies enable the creation of various types of high-resolution baby brain atlases. What is becoming clear is that one atlas is not sufficient to characterize the existing knowledge about the anatomical variations, disease-related anatomical alterations, and the variations in time-dependent changes. In this review, the types and roles of the human baby brain MRI atlases that are currently available are described and discussed, and future directions in the field of developmental neuroscience and its clinical applications are proposed. The potential use of disease-based atlases to characterize clinically relevant information, such as clinical labels, in addition to conventional anatomical labels, is also discussed.
Collapse
Affiliation(s)
- Kenichi Oishi
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| | - Linda Chang
- Departments of Diagnostic Radiology and Nuclear Medicine, and Neurology, University of Maryland School of Medicine, Baltimore, MD, USA; Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, MD, USA; Department of Medicine, John A. Burns School of Medicine, University of Hawaii at Manoa, Honolulu, HI, USA
| | - Hao Huang
- Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA; Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| |
Collapse
|
9
|
Mattern H, Sciarra A, Godenschweger F, Stucht D, Lüsebrink F, Rose G, Speck O. Prospective motion correction enables highest resolution time-of-flight angiography at 7T. Magn Reson Med 2017; 80:248-258. [PMID: 29230871 DOI: 10.1002/mrm.27033] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 11/10/2017] [Accepted: 11/13/2017] [Indexed: 12/15/2022]
Abstract
PURPOSE Higher magnetic field strengths enable time-of-flight (TOF) angiography with higher resolution to depict small-vessel pathologies. However, this potential is limited by the subject's ability to remain motionless. Even small-scale, involuntary motion can degrade vessel depiction, thus limiting the effective resolution. The aim of this study was to overcome this resolution limit by deploying prospectively motion-corrected (PMC) TOF. METHODS An optical, marker-based, in-bore tracking system was used to update the imaging volume prospectively according to the subject's head motion. PMC TOF was evaluated in 12 healthy, cooperative subjects at isotropic resolution of up to 150 μm. Image quality was assessed qualitatively through reader rating and quantitatively with the average edge-strength metric. RESULTS PMC significantly increased the average edge strength and qualitatively improved the vessel depiction in nine out of 11 cases. Image quality was never degraded by motion correction. PMC also enabled acquisition of the highest resolution human brain in vivo TOF angiography to date. CONCLUSION With PMC enabled, high-resolution TOF is able to visualize brain vasculature beyond the effective resolution limit. Magn Reson Med 80:248-258, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Hendrik Mattern
- Department of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany
| | - Alessandro Sciarra
- Department of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany
| | - Frank Godenschweger
- Department of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany
| | - Daniel Stucht
- Department of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany
| | - Falk Lüsebrink
- Department of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany
| | - Georg Rose
- Chair for Healthcare Telematics and Medical Engineering, Otto-von-Guericke-University, Magdeburg, Germany
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, Institute of Experimental Physics, Otto-von-Guericke-University, Magdeburg, Germany.,German Center for Neurodegenerative Diseases, Magdeburg, Germany.,Center for Behavioral Brain Sciences, Magdeburg, Germany.,Leibniz Institute for Neurobiology, Magdeburg, Germany
| |
Collapse
|
10
|
T 1-weighted in vivo human whole brain MRI dataset with an ultrahigh isotropic resolution of 250 μm. Sci Data 2017; 4:170032. [PMID: 28291265 PMCID: PMC5349250 DOI: 10.1038/sdata.2017.32] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Accepted: 02/08/2017] [Indexed: 11/08/2022] Open
Abstract
We present an ultrahigh resolution in vivo human brain magnetic resonance imaging (MRI) dataset. It consists of T1-weighted whole brain anatomical data acquired at 7 Tesla with a nominal isotropic resolution of 250 μm of a single young healthy Caucasian subject and was recorded using prospective motion correction. The raw data amounts to approximately 1.2 TB and was acquired in eight hours total scan time. The resolution of this dataset is far beyond any previously published in vivo structural whole brain dataset. Its potential use is to build an in vivo MR brain atlas. Methods for image reconstruction and image restoration can be improved as the raw data is made available. Pre-processing and segmentation procedures can possibly be enhanced for high magnetic field strength and ultrahigh resolution data. Furthermore, potential resolution induced changes in quantitative data analysis can be assessed, e.g., cortical thickness or volumetric measures, as high quality images with an isotropic resolution of 1 and 0.5 mm of the same subject are included in the repository as well.
Collapse
|
11
|
Zaitsev M, Akin B, LeVan P, Knowles BR. Prospective motion correction in functional MRI. Neuroimage 2016; 154:33-42. [PMID: 27845256 DOI: 10.1016/j.neuroimage.2016.11.014] [Citation(s) in RCA: 72] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Revised: 11/04/2016] [Accepted: 11/05/2016] [Indexed: 10/20/2022] Open
Abstract
Due to the intrinsic low sensitivity of BOLD-fMRI long scanning is required. Subject motion during fMRI scans reduces statistical significance of the activation maps and increases the prevalence of false activations. Motion correction is therefore an essential tool for a successful fMRI data analysis. Retrospective motion correction techniques are now commonplace and are incorporated into a wide range of fMRI analysis toolboxes. These techniques are advantageous due to robustness, sequence independence and have minimal impact on the fMRI study setup. Retrospective techniques however, do not provide an accurate intra-volume correction, nor can these techniques correct for the spin-history effects. The application of prospective motion correction in fMRI appears to be effective in reducing false positives and increasing sensitivity when compared to retrospective techniques, particularly in the cases of substantial motion. Especially advantageous in this regard is the combination of prospective motion correction with dynamic distortion correction. Nevertheless, none of the recent methods are able to recover activations in presence of motion that are comparable to no-motion conditions, which motivates further research in the area of adaptive dynamic imaging.
Collapse
Affiliation(s)
- Maxim Zaitsev
- Department of Radiology - Medical Physics, University of Freiburg, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Germany.
| | - Burak Akin
- Department of Radiology - Medical Physics, University of Freiburg, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Germany
| | - Pierre LeVan
- Department of Radiology - Medical Physics, University of Freiburg, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Germany
| | - Benjamin R Knowles
- Department of Radiology - Medical Physics, University of Freiburg, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Germany
| |
Collapse
|
12
|
Godenschweger F, Kägebein U, Stucht D, Yarach U, Sciarra A, Yakupov R, Lüsebrink F, Schulze P, Speck O. Motion correction in MRI of the brain. Phys Med Biol 2016; 61:R32-56. [PMID: 26864183 DOI: 10.1088/0031-9155/61/5/r32] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Subject motion in MRI is a relevant problem in the daily clinical routine as well as in scientific studies. Since the beginning of clinical use of MRI, many research groups have developed methods to suppress or correct motion artefacts. This review focuses on rigid body motion correction of head and brain MRI and its application in diagnosis and research. It explains the sources and types of motion and related artefacts, classifies and describes existing techniques for motion detection, compensation and correction and lists established and experimental approaches. Retrospective motion correction modifies the MR image data during the reconstruction, while prospective motion correction performs an adaptive update of the data acquisition. Differences, benefits and drawbacks of different motion correction methods are discussed.
Collapse
Affiliation(s)
- F Godenschweger
- Biomedical Magnetic Resonance, Otto-von-Guericke University, Magdeburg, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|