Du F, Li N, Yang X, Zhang B, Zhang X, Li Y. Design and construction of an 8-channel transceiver coil array for rat imaging at 9.4 T. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 351:107302. [PMID: 37116433 DOI: 10.1016/j.jmr.2022.107302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 08/27/2022] [Accepted: 09/11/2022] [Indexed: 05/29/2023]
Abstract
Ultra-high field (UHF) small animal magnetic resonance imaging (MRI) is a crucial tool permitting investigation of metabolic diseases and identification of imaging biomarkers suitable for clinical diagnosis and translation. Radiofrequency (RF) coils are critical components in enabling acquisition of high-quality rat abdomen MRI data. However, efficient RF coils with high-channel count, capable of sensitive and accelerated rat abdomen imaging at 9.4 T, are not available commercially. The SNR of the commonly-used 9.4 T birdcage coil is relatively weak, particularly in the peripheral area of the subject. In addition, the birdcage is not readily to perform parallel imaging due to unavailability of the required multiple channels. Consequently, the extended scanning duration may cause unnecessary hazards to the rat. In this work, an 8-channel transceiver coil array was designed and constructed to provide good image quality and large coverage for rat abdomen imaging at 9.4 T. The structure and the performance of the developed array was optimized and evaluated by numerical electromagnetic simulations and bench tests, respectively. The MR imaging experiments in phantoms and rat models were also performed on a Bruker 9.4 T preclinical MRI system to validate the feasibility of the proposed design. The coil array supports a one-dimensional acceleration factor up to R = 4, providing good parallel imaging capabilities. These results demonstrated that the proposed 8-channel transceiver coil array for rat imaging has the ability to obtain high spatial resolution of rat abdomen anatomical structure images at 9.4 T.
Collapse
Affiliation(s)
- Feng Du
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen 518055, Guang Dong, China
| | - Nan Li
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen 518055, Guang Dong, China
| | - Xing Yang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen 518055, Guang Dong, China
| | - Baogui Zhang
- State Key Laboratory of Brain and Cognitive Sciences, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China; University of Chinese Academy of Sciences, Beijing, China; Brainnetome Center, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China
| | - Xiaoliang Zhang
- Department of Biomedical Engineering, State University of New York at Buffalo, NY, United States., Buffalo, NY, United States
| | - Ye Li
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen 518055, Guang Dong, China.
| |
Collapse
|
2
|
Vaidya MV, Zhang B, Hong D, Brown R, Batsios G, Viswanath P, Paska J, Wulf G, Grant AK, Ronen SM, Larson PEZ. A 13C/ 31P surface coil to visualize metabolism and energetics in the rodent brain at 3 Tesla. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 343:107286. [PMID: 36075133 PMCID: PMC9721620 DOI: 10.1016/j.jmr.2022.107286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 08/04/2022] [Accepted: 08/24/2022] [Indexed: 06/15/2023]
Abstract
PURPOSE We constructed a 13C/31P surface coil at 3 T for studying cancer metabolism and bioenergetics. In a single scan session, hyperpolarized 13C-pyruvate MRS and 31P MRS was carried out for a healthy rat brain. METHODS All experiments were carried out at 3 Tesla. The multinuclear surface coil was designed as two coplanar loops each tuned to either the 13C or 31P operating frequency with an LCC trap on the 13C loop. A commercial volume proton coil was used for anatomical localization and B0 shimming. Single tuned coils operating at either the 13C or 31P frequency were built to evaluate the relative performance of the multinuclear coil. Coil performance metrics consisted of measuring Q factor ratio, calculating system input power using a single-pulse acquisition, and acquiring SNR and flip angle maps using 2D CSI sequences. To observe in vivo spectra, a bolus of hyperpolarized [1-13C] pyruvate was administered via tail vein. In vivo13C and endogenous 31P spectra were obtained in a single scan session using 1D slice selective acquisitions. RESULTS When compared with single tuned surface coils, the multinuclear coil performance showed a decrease in Q factor ratio, SNR, and transmit efficiency. Flip angle maps showed adequate flip angles within the phantom when the transmit voltage was set using an external phantom. Results show good detection of 13C labeled lactate, alanine, and bicarbonate in addition to ATP from 31P MRS. CONCLUSIONS The coil enables obtaining complementary information within a scan session, thus reducing the number of trials and minimizing biological variability for studies of metabolism and bioenergetics.
Collapse
Affiliation(s)
- Manushka V Vaidya
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
| | - Bei Zhang
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - DongHyun Hong
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA
| | - Ryan Brown
- Center for Advanced Imaging Innovation and Research, and Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA
| | - Georgios Batsios
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA
| | - Pavithra Viswanath
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA
| | - Jan Paska
- Center for Advanced Imaging Innovation and Research, and Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA
| | - Gerburg Wulf
- Department of Hematology-Oncology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Aaron K Grant
- Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Sabrina M Ronen
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA
| | - Peder E Z Larson
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA
| |
Collapse
|
3
|
Avdievich NI, Solomakha G, Ruhm L, Henning A, Scheffler K. 9.4 T double-tuned 13 C/ 1 H human head array using a combination of surface loops and dipole antennas. NMR IN BIOMEDICINE 2021; 34:e4577. [PMID: 34169590 DOI: 10.1002/nbm.4577] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/17/2021] [Accepted: 06/02/2021] [Indexed: 06/13/2023]
Abstract
MRI at ultra-high field (UHF, ≥7 T) provides a natural strategy for improving the quality of X-nucleus magnetic resonance spectroscopy and imaging due to the intrinsic benefit of increased signal-to-noise ratio. Considering that RF coils require both local transmission and reception at UHF, the designs of double-tuned coils, which often consist of several layers of transmit and receive resonant elements, become quite complex. A few years ago, a new type of RF coil, ie a dipole antenna, was developed and used for human body and head imaging at UHF. Due to the mechanical and electrical simplicity of dipole antennas, combining an X-nucleus surface loop array with 1 H dipoles can substantially simplify the design of a double-tuned UHF human head array coil. Recently, we developed a novel bent folded-end dipole transceiver array for human head imaging at 9.4 T. The new eight-element dipole array demonstrated full brain coverage, and transmit efficiency comparable to that of the substantially more complex 16-element surface loop array. In this work, we developed, constructed and evaluated a double-tuned 13 C/1 H human head 9.4 T array consisting of eight 13 C transceiver surface loops and eight 1 H transceiver bent folded-end dipole antennas all placed in a single layer. We showed that interaction between loops and dipoles can be minimized by placing four 1 H traps into each 13 C loop. The presented double-tuned RF array coil substantially simplifies the design as compared with the common double-tuned surface loop arrays. At the same time, the coil demonstrated an improved 1 H longitudinal coverage and good transmit efficiency.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Georgiy Solomakha
- Department of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| |
Collapse
|
4
|
von Morze C, Engelbach JA, Blazey T, Quirk JD, Reed GD, Ippolito JE, Garbow JR. Comparison of hyperpolarized 13 C and non-hyperpolarized deuterium MRI approaches for imaging cerebral glucose metabolism at 4.7 T. Magn Reson Med 2020; 85:1795-1804. [PMID: 33247884 DOI: 10.1002/mrm.28612] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 10/12/2020] [Accepted: 11/03/2020] [Indexed: 12/23/2022]
Abstract
PURPOSE The purpose of this study was to directly compare two isotopic metabolic imaging approaches, hyperpolarized (HP) 13 C MRI and deuterium metabolic imaging (DMI), for imaging specific closely related segments of cerebral glucose metabolism at 4.7 T. METHODS Comparative HP-13 C and DMI neuroimaging experiments were conducted consecutively in normal rats during the same scanning session. Localized conversions of [1-13 C]pyruvate and [6,6-2 H2 ]glucose to their respective downstream metabolic products were measured by spectroscopic imaging, using an identical 2D-CSI sequence with parameters optimized for the respective experiments. To facilitate direct comparison, a pair of substantially equivalent 2.5-cm double-tuned X/1 H RF surface coils was developed. For improved results, multidimensional low-rank reconstruction was applied to denoise the raw DMI data. RESULTS Localized conversion of HP [1-13 C]pyruvate to [1-13 C]lactate, and [6,6-2 H2 ]glucose to [3,3-2 H2 ]lactate and Glx-d (glutamate and glutamine), was detected in rat brain by spectroscopic imaging at 4.7 T. The SNR and spatial resolution of HP-13 C MRI was superior to DMI but limited to a short time window, whereas the lengthy DMI acquisition yielded maps of not only lactate, but also Glx production, albeit with relatively poor spectral discrimination between metabolites at this field strength. Across the individual rats, there was an apparent inverse correlation between cerebral production of HP [1-13 C]lactate and Glx-d, along with a trend toward increased [3,3-2 H2 ]lactate. CONCLUSION The HP-13 C MRI and DMI methods are both feasible at 4.7 T and have significant potential for metabolic imaging of specific segments of glucose metabolism.
Collapse
Affiliation(s)
- Cornelius von Morze
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri, USA
| | - John A Engelbach
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri, USA
| | - Tyler Blazey
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri, USA
| | - James D Quirk
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri, USA
| | | | - Joseph E Ippolito
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri, USA
| | - Joel R Garbow
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri, USA
| |
Collapse
|
5
|
von Morze C, Engelbach JA, Reed GD, Chen AP, Quirk JD, Blazey T, Mahar R, Malloy CR, Garbow JR, Merritt ME. 15 N-carnitine, a novel endogenous hyperpolarized MRI probe with long signal lifetime. Magn Reson Med 2020; 85:1814-1820. [PMID: 33179825 DOI: 10.1002/mrm.28578] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 10/05/2020] [Accepted: 10/09/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE The purpose of this study was to investigate hyperpolarization and in vivo imaging of [15 N]carnitine, a novel endogenous MRI probe with long signal lifetime. METHODS L-[15 N]carnitine-d9 was hyperpolarized by the method of dynamic nuclear polarization followed by rapid dissolution. The T1 signal lifetimes were estimated in aqueous solution and in vivo following intravenous injection in rats, using a custom-built dual-tuned 15 N/1 H RF coil at 4.7 T. 15 N chemical shift imaging and 15 N fast spin-echo images of rat abdomen were acquired 3 minutes after [15 N]carnitine injection. RESULTS Estimated T1 times of [15 N]carnitine at 4.7 T were 210 seconds (in H2 O) and 160 seconds (in vivo), with an estimated polarization level of 10%. Remarkably, the [15 N]carnitine coherence was detectable in rat abdomen for 5 minutes after injection for the nonlocalized acquisition. No downstream metabolites were detected on localized or nonlocalized 15 N spectra. Diffuse liver enhancement was detected on 15 N fast spin-echo imaging 3 minutes after injection, with mean hepatic SNR of 18 ± 5 at a spatial resolution of 4 × 4 mm. CONCLUSION This study showed the feasibility of hyperpolarizing and imaging the biodistribution of HP [15 N]carnitine.
Collapse
Affiliation(s)
- Cornelius von Morze
- Mallinckrodt Institute of Radiology, Washington University, St Louis, Missouri, USA
| | - John A Engelbach
- Mallinckrodt Institute of Radiology, Washington University, St Louis, Missouri, USA
| | | | | | - James D Quirk
- Mallinckrodt Institute of Radiology, Washington University, St Louis, Missouri, USA
| | - Tyler Blazey
- Mallinckrodt Institute of Radiology, Washington University, St Louis, Missouri, USA
| | - Rohit Mahar
- Department of Biochemistry, University of Florida, Gainesville, Florida, USA
| | - Craig R Malloy
- Advanced Imaging Research Center, University of Texas, Southwestern, Dallas, Texas, USA
| | - Joel R Garbow
- Mallinckrodt Institute of Radiology, Washington University, St Louis, Missouri, USA
| | - Matthew E Merritt
- Department of Biochemistry, University of Florida, Gainesville, Florida, USA
| |
Collapse
|
6
|
Choi CH, Hong SM, Felder J, Shah NJ. The state-of-the-art and emerging design approaches of double-tuned RF coils for X-nuclei, brain MR imaging and spectroscopy: A review. Magn Reson Imaging 2020; 72:103-116. [DOI: 10.1016/j.mri.2020.07.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/16/2020] [Accepted: 07/01/2020] [Indexed: 12/18/2022]
|
7
|
Topping GJ, Hundshammer C, Nagel L, Grashei M, Aigner M, Skinner JG, Schulte RF, Schilling F. Acquisition strategies for spatially resolved magnetic resonance detection of hyperpolarized nuclei. MAGMA (NEW YORK, N.Y.) 2020; 33:221-256. [PMID: 31811491 PMCID: PMC7109201 DOI: 10.1007/s10334-019-00807-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 10/08/2019] [Accepted: 11/21/2019] [Indexed: 12/13/2022]
Abstract
Hyperpolarization is an emerging method in magnetic resonance imaging that allows nuclear spin polarization of gases or liquids to be temporarily enhanced by up to five or six orders of magnitude at clinically relevant field strengths and administered at high concentration to a subject at the time of measurement. This transient gain in signal has enabled the non-invasive detection and imaging of gas ventilation and diffusion in the lungs, perfusion in blood vessels and tissues, and metabolic conversion in cells, animals, and patients. The rapid development of this method is based on advances in polarizer technology, the availability of suitable probe isotopes and molecules, improved MRI hardware and pulse sequence development. Acquisition strategies for hyperpolarized nuclei are not yet standardized and are set up individually at most sites depending on the specific requirements of the probe, the object of interest, and the MRI hardware. This review provides a detailed introduction to spatially resolved detection of hyperpolarized nuclei and summarizes novel and previously established acquisition strategies for different key areas of application.
Collapse
Affiliation(s)
- Geoffrey J Topping
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Christian Hundshammer
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Luca Nagel
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Martin Grashei
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Maximilian Aigner
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jason G Skinner
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Franz Schilling
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
| |
Collapse
|
8
|
Davoodi H, Jouda M, Korvink JG, MacKinnon N, Badilita V. Broadband and multi-resonant sensors for NMR. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019; 112-113:34-54. [PMID: 31481158 DOI: 10.1016/j.pnmrs.2019.05.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 05/08/2019] [Accepted: 05/08/2019] [Indexed: 06/10/2023]
Abstract
It has always been of considerable interest to study the nuclear magnetic resonance response of multiple nuclei simultaneously, whether these signals arise from internuclear couplings within the same molecule, or from uncoupled nuclei within sample mixtures. The literature contains numerous uncorrelated reports on techniques employed to achieve multi-nuclear NMR detection. This paper consolidates the subset of techniques in which single coil detectors are utilized, and highlights the strengths and weaknesses of each approach, at the same time pointing the way towards future developments in the field of multi-nuclear NMR. We compare the different multi-nuclear NMR techniques in terms of performance, and present a guide to NMR probe designers towards application-based optimum design. We also review the applicability of micro-coils in the context of multi-nuclear methods. Micro-coils benefit from compact geometries and exhibit lower impedance, which provide new opportunities and challenges for the NMR probe designer.
Collapse
Affiliation(s)
- Hossein Davoodi
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Mazin Jouda
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Jan G Korvink
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany.
| | - Neil MacKinnon
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany
| | - Vlad Badilita
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany.
| |
Collapse
|
9
|
Sanchez-Heredia JD, Szocska Hansen ES, Laustsen C, Zhurbenko V, Ardenkjær-Larsen JH. Low-Noise Active Decoupling Circuit and its Application to 13C Cryogenic RF Coils at 3 T. ACTA ACUST UNITED AC 2017; 3:60-66. [PMID: 30042972 PMCID: PMC6024423 DOI: 10.18383/j.tom.2016.00280] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
We analyze the loss contributions in a small, 50-mm-diameter receive-only coil for carbon-13 (13C) magnetic resonance imaging at 3 T for 3 different circuits, which, including active decoupling, are compared in terms of their Q-factors and signal-to-noise ratio (SNR). The results show that a circuit using unsegmented tuning and split matching capacitors can provide >20% SNR enhancement at room temperature compared with that using more traditional designs. The performance of the proposed circuit was also measured when cryogenically cooled to 105 K, and an additional 1.6-fold SNR enhancement was achieved on a phantom. The enhanced circuit performance is based on the low capacitance needed to match to 50 Ω when coil losses are low, which significantly reduces the proportion of the current flowing through the matching network and therefore minimizes this loss contribution. This effect makes this circuit particularly suitable for receive-only cryogenic coils and/or small coils for low-gamma nuclei.
Collapse
Affiliation(s)
- Juan Diego Sanchez-Heredia
- Department of Electrical Engineering, Technical University of Denmark, Kongens Lyngby, Copenhagen, Denmark and
| | | | - Christoffer Laustsen
- MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Vitaliy Zhurbenko
- Department of Electrical Engineering, Technical University of Denmark, Kongens Lyngby, Copenhagen, Denmark and
| | - Jan Henrik Ardenkjær-Larsen
- Department of Electrical Engineering, Technical University of Denmark, Kongens Lyngby, Copenhagen, Denmark and
| |
Collapse
|