1
|
Klepochová R, Niess F, Meyerspeer M, Slukova D, Just I, Trattnig S, Ukropec J, Ukropcová B, Kautzky-Willer A, Leutner M, Krššák M. Correlation between skeletal muscle acetylcarnitine and phosphocreatine metabolism during submaximal exercise and recovery: interleaved 1H/ 31P MRS 7 T study. Sci Rep 2024; 14:3254. [PMID: 38332163 PMCID: PMC10853526 DOI: 10.1038/s41598-024-53221-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 01/30/2024] [Indexed: 02/10/2024] Open
Abstract
Acetylcarnitine is an essential metabolite for maintaining metabolic flexibility and glucose homeostasis. The in vivo behavior of muscle acetylcarnitine content during exercise has not been shown with magnetic resonance spectroscopy. Therefore, this study aimed to explore the behavior of skeletal muscle acetylcarnitine during rest, plantar flexion exercise, and recovery in the human gastrocnemius muscle under aerobic conditions. Ten lean volunteers and nine overweight volunteers participated in the study. A 7 T whole-body MR system with a double-tuned surface coil was used to acquire spectra from the gastrocnemius medialis. An MR-compatible ergometer was used for the plantar flexion exercise. Semi-LASER-localized 1H MR spectra and slab-localized 31P MR spectra were acquired simultaneously in one interleaved exercise/recovery session. The time-resolved interleaved 1H/31P MRS acquisition yielded excellent data quality. A between-group difference in acetylcarnitine metabolism over time was detected. Significantly slower τPCr recovery, τPCr on-kinetics, and lower Qmax in the overweight group, compared to the lean group was found. Linear relations between τPCr on-kinetics, τPCr recovery, VO2max and acetylcarnitine content were identified. In conclusion, we are the first to show in vivo changes of skeletal muscle acetylcarnitine during acute exercise and immediate exercise recovery with a submaximal aerobic workload using interleaved 1H/31P MRS at 7 T.
Collapse
Affiliation(s)
- Radka Klepochová
- Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
- High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Fabian Niess
- High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Martin Meyerspeer
- High-Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Dorota Slukova
- Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Ivica Just
- Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
- High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Siegfried Trattnig
- High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging (MOLIMA), Vienna, Austria
| | - Jozef Ukropec
- Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Barbara Ukropcová
- Institute of Experimental Endocrinology, Biomedical Research Center, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Alexandra Kautzky-Willer
- Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Michael Leutner
- Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Martin Krššák
- Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
- High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
2
|
Lopez Kolkovsky AL, Carlier PG, Marty B, Meyerspeer M. Interleaved and simultaneous multi-nuclear magnetic resonance in vivo. Review of principles, applications and potential. NMR IN BIOMEDICINE 2022; 35:e4735. [PMID: 35352440 PMCID: PMC9542607 DOI: 10.1002/nbm.4735] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 03/03/2022] [Accepted: 03/28/2022] [Indexed: 06/14/2023]
Abstract
Magnetic resonance signals from different nuclei can be excited or received at the same time,rendering simultaneous or rapidly interleaved multi-nuclear acquisitions feasible. The advan-tages are a reduction of total scan time compared to sequential multi-nuclear acquisitions or that additional information from heteronuclear data is obtained at thesame time and anatomical position. Information content can be qualitatively increased by delivering a more comprehensive MR-based picture of a transient state (such as an exercise bout). Also, combiningnon-proton MR acquisitions with 1 Hinformation (e.g., dynamic shim updates and motion correction) can be used to improve data quality during long scans and benefits image coregistration. This work reviews the literature on interleaved and simultaneous multi-nuclear MRI and MRS in vivo. Prominent use cases for this methodology in clinical and research applications are brain and muscle, but studies have also been carried out in other targets, including the lung, knee, breast and heart. Simultaneous multi-nuclear measurements in the liver and kidney have also been performed, but exclusively in rodents. In this review, a consistent nomenclature is proposed, to help clarify the terminology used for this principle throughout the literature on in-vivo MR. An overview covers the basic principles, the technical requirements on the MR scanner and the implementations realised either by MR system vendors or research groups, from the early days until today. Considerations regarding the multi-tuned RF coils required and heteronuclear polarisation interactions are briefly discussed, and fields for future in-vivo applications for interleaved multi-nuclear MR pulse sequences are identified.
Collapse
Affiliation(s)
- Alfredo L. Lopez Kolkovsky
- NMR Laboratory, Neuromuscular Investigation CenterInstitute of MyologyParisFrance
- NMR laboratoryCEA, DRF, IBFJParisFrance
| | - Pierre G. Carlier
- NMR Laboratory, Neuromuscular Investigation CenterInstitute of MyologyParisFrance
- NMR laboratoryCEA, DRF, IBFJParisFrance
| | - Benjamin Marty
- NMR Laboratory, Neuromuscular Investigation CenterInstitute of MyologyParisFrance
- NMR laboratoryCEA, DRF, IBFJParisFrance
| | - Martin Meyerspeer
- High‐Field MR Center, Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| |
Collapse
|
3
|
Dehghani M, Edden R, Near J. Hadamard-encoded dual-voxel SPECIAL: Short-TE MRS acquired in two brain regions simultaneously using Hadamard encoding. Magn Reson Med 2021; 87:1649-1660. [PMID: 34932240 DOI: 10.1002/mrm.29129] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 11/09/2021] [Accepted: 12/01/2021] [Indexed: 12/20/2022]
Abstract
PURPOSE The spin-echo, full-intensity acquired localized (SPECIAL) sequence is a method for single-voxel, localized MRS in vivo with short TEs. In this study we modified the SPECIAL sequence to simultaneously record spectra from two volumes of interest. This new technique is called Hadamard-encoded dual-voxel SPECIAL (HD-SPECIAL). METHODS The SPECIAL sequence consists of a spin echo localized to a column of tissue, preceded by a slice-selective inversion pulse in alternating scans to invert a section of the column. Full localization is achieved by subtraction of the inversion-on scans from the inversion-off scans. In HD-SPECIAL, the two-step inversion scheme is replaced by a four-step Hadamard-encoded scheme involving single-band and dual-band inversion pulses to select two regions of the spin-echo column. By appropriate Hadamard combination of the four acquired shots, spectra can be reconstructed from both desired regions. This approach does not rely on parallel imaging reconstruction. Using a 3T scanner, HD-SPECIAL localization is demonstrated both in phantoms and in the human brain in vivo, and the performance of HD-SPECIAL is assessed by comparing with the conventional SPECIAL sequence. RESULTS Phantom and in vivo measurements show excellent agreement between measures from HD-SPECIAL and SPECIAL sequences. Relative to consecutive SPECIAL measurements from two regions, HD-SPECIAL reduces the total scan time 2-fold with minimal penalty in terms of spectral quality or SNR. CONCLUSION The HD-SPECIAL sequence enables reliable acquisition of MR spectra simultaneously from two regions at 3 T, offering the potential to study interregional variations in metabolite concentrations.
Collapse
Affiliation(s)
- Masoumeh Dehghani
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.,Department of Psychiatry, McGill University, Montreal, Quebec, Canada.,Centre d'Imagerie Cérébrale, Douglas Mental Health University, Montreal, Quebec, Canada
| | - Richard Edden
- Centre d'Imagerie Cérébrale, Douglas Mental Health University, Montreal, Quebec, Canada.,FM Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.,Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institutions, Baltimore, Maryland, USA
| | - Jamie Near
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.,Department of Psychiatry, McGill University, Montreal, Quebec, Canada.,Centre d'Imagerie Cérébrale, Douglas Mental Health University, Montreal, Quebec, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
4
|
Dorst J, Ruhm L, Avdievich N, Bogner W, Henning A. Comparison of four 31P single-voxel MRS sequences in the human brain at 9.4 T. Magn Reson Med 2021; 85:3010-3026. [PMID: 33427322 DOI: 10.1002/mrm.28658] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 12/03/2020] [Accepted: 12/06/2020] [Indexed: 01/30/2023]
Abstract
PURPOSE In this study, different single-voxel localization sequences were implemented and systematically compared for the first time for phosphorous MRS (31 P-MRS) in the human brain at 9.4 T. METHODS Two multishot sequences, image-selected in vivo spectroscopy (ISIS) and a conventional slice-selective excitation combined with localization by adiabatic selective refocusing (semiLASER) variant of the spin-echo full intensity-acquired localized spectroscopy (SPECIAL-semiLASER), and two single-shot sequences, semiLASER and stimulated echo acquisition mode (STEAM), were implemented and optimized for 31 P-MRS in the human brain at 9.4 T. Pulses and coil setup were optimized, localization accuracy was tested in phantom experiments, and absolute SNR of the sequences was compared in vivo. The SNR per unit time (SNR/t) was derived and compared for all four sequences and verified experimentally for ISIS in two different voxel sizes (3 × 3 × 3 cm3 , 5 × 5 × 5 cm3 , 10-minute measurement time). Metabolite signals obtained with ISIS were quantified. The possible spectral quality in vivo acquired in clinically feasible time (3:30 minutes, 3 × 3 × 3 cm3 ) was explored for two different coil setups. RESULTS All evaluated sequences performed with good localization accuracy in phantom experiments and provided well-resolved spectra in vivo. However, ISIS has the lowest chemical shift displacement error, the best localization accuracy, the highest SNR/t for most metabolites, provides metabolite concentrations comparable to literature values, and is the only one of the sequences that allows for the detection of the whole 31 P spectrum, including β-adenosine triphosphate, with the used setup. The SNR/t of STEAM is comparable to the SNR/t of ISIS. The semiLASER and SPECIAL-semiLASER sequences provide good results for metabolites with long T2 . CONCLUSION At 9.4 T, high-quality single-voxel localized 31 P-MRS can be performed in the human brain with different localization methods, each with inherent characteristics suitable for different research issues.
Collapse
Affiliation(s)
- Johanna Dorst
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, University of Tübingen, Tübingen, Germany
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, University of Tübingen, Tübingen, Germany
| | - Nikolai Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Wolfgang Bogner
- High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
5
|
Santos-Díaz A, Noseworthy MD. Phosphorus magnetic resonance spectroscopy and imaging (31P-MRS/MRSI) as a window to brain and muscle metabolism: A review of the methods. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.101967] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
6
|
Niess F, Schmid AI, Bogner W, Wolzt M, Carlier P, Trattnig S, Moser E, Meyerspeer M. Interleaved 31 P MRS/ 1 H ASL for analysis of metabolic and functional heterogeneity along human lower leg muscles at 7T. Magn Reson Med 2020; 83:1909-1919. [PMID: 31846116 PMCID: PMC7065182 DOI: 10.1002/mrm.28088] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 10/16/2019] [Accepted: 10/28/2019] [Indexed: 12/16/2022]
Abstract
PURPOSE MR offers the unique possibility to noninvasively investigate cellular energy metabolism via 31P MRS, while blood perfusion, which provides oxygen and substrates to the tissue, is accessible by arterial spin labeling (ASL) 1H MRI. Because metabolic and hemodynamic parameters are linked, it would be desirable to study them simultaneously. A 3D-resolved method is presented that allows such measurements with high spatiotemporal resolution and has the potential to discern differences along an exercising muscle. METHODS Multi-voxel localized 31 P MRS was temporally interleaved with multi-slice pASL 1H MRI. Phosphorus spectra were collected from two adjacent positions in gastrocnemius medialis (GM) during rest, submaximal plantar flexion exercise and recovery, while perfusion and T 2 * -weighted axial images were acquired at the same time. Seventeen healthy volunteers (9 f / 8 m) were studied at 7 T. RESULTS An increase of postexercise perfusion and T 2 * -weighted signal in GM positively correlated with end-exercise PCr depletion and pH drop. At proximal positions functional and metabolic activity was higher than distally, that is, perfusion increase and peak T 2 * -weighted signal, end-exercise PCr depletion, end-exercise pH, and PCr recovery time constant were significantly different. An NOE-induced SNR increase of approximately 20 % (P < .001), at rest, was found in interleaved 31 P spectra, when comparing to 31 P-only acquisitions. CONCLUSIONS A technique for fast, simultaneous imaging of muscle functional heterogeneity in ASL, T 2 * and acquisition of time-resolved 31 P MRS data is presented. These single exercise recovery experiments can be used to investigate local variations during disease progression in patients suffering from vascular or muscular diseases.
Collapse
Affiliation(s)
- Fabian Niess
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
- High Field MR CenterMedical University of ViennaViennaAustria
| | - Albrecht Ingo Schmid
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
- High Field MR CenterMedical University of ViennaViennaAustria
| | - Wolfgang Bogner
- High Field MR CenterMedical University of ViennaViennaAustria
- Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Michael Wolzt
- Department of Clinical PharmacologyMedical University of ViennaViennaAustria
| | | | - Siegfried Trattnig
- High Field MR CenterMedical University of ViennaViennaAustria
- Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Ewald Moser
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
- High Field MR CenterMedical University of ViennaViennaAustria
| | - Martin Meyerspeer
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
- High Field MR CenterMedical University of ViennaViennaAustria
| |
Collapse
|
7
|
Juras V, Mlynarik V, Szomolanyi P, Valkovič L, Trattnig S. Magnetic Resonance Imaging of the Musculoskeletal System at 7T: Morphological Imaging and Beyond. Top Magn Reson Imaging 2019; 28:125-135. [PMID: 30951006 PMCID: PMC6565434 DOI: 10.1097/rmr.0000000000000205] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
In 2017, a whole-body 7T magnetic resonance imaging (MRI) device was given regulatory approval for clinical use in both the EU and United States for neuro and musculoskeletal applications. As 7 Tesla allows for higher signal-to-noise , which results in higher resolution images than those obtained on lower-field-strength scanners, it has attracted considerable attention from the musculoskeletal field, as evidenced by the increasing number of publications in the last decade. Besides morphological imaging, the quantitative MR methods, such as T2, T2∗, T1ρ mapping, sodium imaging, chemical-exchange saturation transfer, and spectroscopy, substantially benefit from ultrahigh field scanning. In this review, we provide technical considerations for the individual techniques and an overview of (mostly) clinical applications for the assessment of cartilage, tendon, meniscus, and muscle. The first part of the review is dedicated to morphological applications at 7T, and the second part describes the most recent developments in quantitative MRI at 7T.
Collapse
Affiliation(s)
- Vladimir Juras
- High-field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.,Department of Imaging Methods, Institute of Measurements Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Vladimir Mlynarik
- High-field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.,Karl Landsteiner Society, St. Pölten, Austria
| | - Pavol Szomolanyi
- High-field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.,Department of Imaging Methods, Institute of Measurements Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Ladislav Valkovič
- High-field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.,Oxford Centre for Clinical Magnetic Resonance Research, BHF Centre of Research Excellence, University of Oxford, Oxford, UK.,Department of Imaging Methods, Institute of Measurements Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Siegfried Trattnig
- High-field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.,Austrian Cluster for Tissue Regeneration, Vienna, Austria.,Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| |
Collapse
|
8
|
Sedivy P, Dezortova M, Rydlo J, Drobny M, Krssak M, Valkovic L, Hajek M. MR compatible ergometers for dynamic 31P MRS. J Appl Biomed 2019; 17:91-98. [PMID: 34907736 DOI: 10.32725/jab.2019.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Accepted: 04/15/2019] [Indexed: 11/05/2022] Open
Abstract
Magnetic Resonance (MR) compatible ergometers are specialized ergometers used inside the MR scanners for the characterization of tissue metabolism changes during physical stress. They are most commonly used for dynamic phosphorous magnetic resonance spectroscopy (31P MRS), but can also be used for lactate production measurements, perfusion studies using arterial spin labelling or muscle oxygenation measurements by blood oxygen dependent contrast sequences. We will primarily discuss the importance of ergometers in the context of dynamic 31P MRS. Dynamic 31P MRS can monitor muscle fatigue and energy reserve during muscle contractions as well as the dynamics of recuperation of skeletal muscle tissue during the following recovery through signal changes of phosphocreatine (PCr), inorganic phosphate and adenosine triphosphate (ATP). Based on the measured data it is possible to calculate intracellular pH, metabolic flux of ATP through creatine-kinase reaction, anaerobic glycolysis and oxidative phosphorylation and other metabolic parameters as mitochondrial capacity. This review primarily focuses on describing various technical designs of MR compatible ergometers for dynamic 31P MRS that must be constructed with respect to the presence of magnetic field. It is also expected that the construction of ergometers will be easy for the handling and well accepted by examined subjects.
Collapse
Affiliation(s)
- Petr Sedivy
- Institute for Clinical and Experimental Medicine, Department of Diagnostic and Interventional Radiology, MR-unit, Prague, Czech Republic
| | - Monika Dezortova
- Institute for Clinical and Experimental Medicine, Department of Diagnostic and Interventional Radiology, MR-unit, Prague, Czech Republic
| | - Jan Rydlo
- Institute for Clinical and Experimental Medicine, Department of Diagnostic and Interventional Radiology, MR-unit, Prague, Czech Republic
| | - Miloslav Drobny
- Institute for Clinical and Experimental Medicine, Department of Diagnostic and Interventional Radiology, MR-unit, Prague, Czech Republic
| | - Martin Krssak
- Medical University of Vienna, Department of Internal Medicine III & High Field MR Centre, Division of Endocrinology and Metabolism, Department of Biomedical Imaging and Image guided Therapy, Vienna, Austria.,Christian Doppler Laboratory for Clinical Molecular MR Imaging (MOLIMA), Vienna, Austria
| | - Ladislav Valkovic
- University of Oxford, RDM Cardiovascular Medicine, Oxford Centre for Clinical MR Research (OCMR), Oxford, United Kingdom.,Slovak Academy of Sciences, Institute of Measurement Science, Department of Imaging Methods, Bratislava, Slovakia
| | - Milan Hajek
- Institute for Clinical and Experimental Medicine, Department of Diagnostic and Interventional Radiology, MR-unit, Prague, Czech Republic
| |
Collapse
|
9
|
Santos-Díaz A, Harasym D, Noseworthy MD. Dynamic 31 P spectroscopic imaging of skeletal muscles combining flyback echo-planar spectroscopic imaging and compressed sensing. Magn Reson Med 2019; 81:3453-3461. [PMID: 30737840 DOI: 10.1002/mrm.27682] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 01/09/2019] [Accepted: 01/10/2019] [Indexed: 01/21/2023]
Abstract
PURPOSE Dynamic phosphorus MR spectroscopic imaging (31 P-MRSI) experiments require temporal resolution on the order of seconds to concurrently assess different muscle groups. A highly accelerated pulse sequence combining flyback echo-planar spectroscopic imaging (EPSI) and compressed sensing was developed and tested in a phantom and healthy humans during an exercise-recovery challenge of the lower leg muscles, using a clinical 3T MRI. METHODS A flyback EPSI readout designed to achieve 2.25 × 2.25 cm2 resolution over a 18 × 18 cm2 field of view (i.e., 8 × 8 matrix) was combined with compressed sensing through the inclusion of pseudorandom gradient blips to sub-sample the ky-kt dimensions by a factor of 2.7×, achieving a temporal resolution of 9 s. The sequence was first tested in a phantom to assess performance compared to fully sampled EPSI (fidEPSI) and phase encoded chemical shift imaging (fidCSI). Then, tests were performed in 11 healthy volunteers during an exercise-recovery challenge of the lower leg muscles. Voxels containing tissue from different muscle groups were evaluated measuring percentage phosphocreatine (%PCr) depletion, time constant of PCr recovery (τPCr) and intracellular pH at rest and following exercise. RESULTS The sequence was capable to track the dynamic PCr response of multiple muscles simultaneously. No statistical differences were found in the metabolite ratio, pH or linewidth when compared with fidEPSI and fidCSI in the phantom study. Dynamic experiments showed differences in PCr depletion when comparing soleus with gastrocnemius muscles. Intracellular pH, τPCr and %PCr decrease were consistent with reported values. CONCLUSION Highly accelerated 31 P-MRSI combining flyback EPSI and compressed sensing is capable of assessing concurrent energy metabolism in multiple muscle groups using a clinical 3T MR system.
Collapse
Affiliation(s)
- Alejandro Santos-Díaz
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada.,Imaging Research Center, St. Joseph's Healthcare, Hamilton, Ontario, Canada
| | - Diana Harasym
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada.,Imaging Research Center, St. Joseph's Healthcare, Hamilton, Ontario, Canada
| | - Michael D Noseworthy
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada.,Imaging Research Center, St. Joseph's Healthcare, Hamilton, Ontario, Canada.,Electrical and Computing Engineering, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|
10
|
Ladd ME, Bachert P, Meyerspeer M, Moser E, Nagel AM, Norris DG, Schmitter S, Speck O, Straub S, Zaiss M. Pros and cons of ultra-high-field MRI/MRS for human application. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2018; 109:1-50. [PMID: 30527132 DOI: 10.1016/j.pnmrs.2018.06.001] [Citation(s) in RCA: 300] [Impact Index Per Article: 42.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 06/06/2018] [Accepted: 06/07/2018] [Indexed: 05/08/2023]
Abstract
Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.
Collapse
Affiliation(s)
- Mark E Ladd
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Medicine, University of Heidelberg, Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany; Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Peter Bachert
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany.
| | - Martin Meyerspeer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Center of Excellence, Medical University of Vienna, Vienna, Austria.
| | - Ewald Moser
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Center of Excellence, Medical University of Vienna, Vienna, Austria.
| | - Armin M Nagel
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | - David G Norris
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen, Nijmegen, Netherlands; Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Sebastian Schmitter
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany; German Center for Neurodegenerative Diseases, Magdeburg, Germany; Center for Behavioural Brain Sciences, Magdeburg, Germany; Leibniz Institute for Neurobiology, Magdeburg, Germany.
| | - Sina Straub
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
| | - Moritz Zaiss
- High-Field Magnetic Resonance Center, Max-Planck-Institute for Biological Cybernetics, Tübingen, Germany.
| |
Collapse
|
11
|
Niess F, Fiedler GB, Schmid AI, Laistler E, Frass‐Kriegl R, Wolzt M, Moser E, Meyerspeer M. Dynamic multivoxel-localized 31 P MRS during plantar flexion exercise with variable knee angle. NMR IN BIOMEDICINE 2018; 31:e3905. [PMID: 29578260 PMCID: PMC6001778 DOI: 10.1002/nbm.3905] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 01/08/2018] [Accepted: 01/16/2018] [Indexed: 05/07/2023]
Abstract
Exercise studies investigating the metabolic response of calf muscles using 31 P MRS are usually performed with a single knee angle. However, during natural movement, the distribution of workload between the main contributors to force, gastrocnemius and soleus is influenced by the knee angle. Hence, it is of interest to measure the respective metabolic response of these muscles to exercise as a function of knee angle using localized spectroscopy. Time-resolved multivoxel 31 P MRS at 7 T was performed simultaneously in gastrocnemius medialis and soleus during rest, plantar flexion exercise and recovery in 12 healthy volunteers. This experiment was conducted with four different knee angles. PCr depletions correlated negatively with knee angle in gastrocnemius medialis, decreasing from 79±14 % (extended leg) to 35±23 %(∼40°), and positively in soleus, increasing from 20±21 % to 36±25 %; differences were significant. Linear correlations were found between knee angle and end-exercise PCr depletions in gastrocnemius medialis (R2 =0.8) and soleus (R2 =0.53). PCr recovery times and end-exercise pH changes that correlated with PCr depletion were consistent with the literature in gastrocnemius medialis and differences between knee angles were significant. These effects were less pronounced in soleus and not significant for comparable PCr depletions. Maximum oxidative capacity calculated for all knee angles was in excellent agreement with the literature and showed no significant changes between different knee angles. In conclusion, these findings confirm that plantar flexion exercise with a straight leg is a suitable paradigm, when data are acquired from gastrocnemius only (using either localized MRS or small surface coils), and that activation of soleus requires the knee to be flexed. The present study comprises a systematic investigation of the effects of the knee angle on metabolic parameters, measured with dynamic multivoxel 31 P MRS during muscle exercise and recovery, and the findings should be used in future study design.
Collapse
Affiliation(s)
- Fabian Niess
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaAustria
- Highfield MR CenterMedical University of ViennaAustria
| | - Georg B. Fiedler
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaAustria
- Highfield MR CenterMedical University of ViennaAustria
| | - Albrecht I. Schmid
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaAustria
- Highfield MR CenterMedical University of ViennaAustria
| | - Elmar Laistler
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaAustria
- Highfield MR CenterMedical University of ViennaAustria
| | - Roberta Frass‐Kriegl
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaAustria
- Highfield MR CenterMedical University of ViennaAustria
| | - Michael Wolzt
- Department of Clinical PharmacologyMedical University of ViennaAustria
| | - Ewald Moser
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaAustria
- Highfield MR CenterMedical University of ViennaAustria
| | - Martin Meyerspeer
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaAustria
- Highfield MR CenterMedical University of ViennaAustria
| |
Collapse
|
12
|
Moll K, Gussew A, Nisser M, Derlien S, Krämer M, Reichenbach JR. Comparison of metabolic adaptations between endurance- and sprint-trained athletes after an exhaustive exercise in two different calf muscles using a multi-slice 31 P-MR spectroscopic sequence. NMR IN BIOMEDICINE 2018; 31:e3889. [PMID: 29393546 DOI: 10.1002/nbm.3889] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 10/20/2017] [Accepted: 12/03/2017] [Indexed: 06/07/2023]
Abstract
Measurements of exercise-induced metabolic changes, such as oxygen consumption, carbon dioxide exhalation or lactate concentration, are important indicators for assessing the current performance level of athletes in training science. With exercise-limiting metabolic processes occurring in loaded muscles, 31 P-MRS represents a particularly powerful modality to identify and analyze corresponding training-induced alterations. Against this background, the current study aimed to analyze metabolic adaptations after an exhaustive exercise in two calf muscles (m. soleus - SOL - and m. gastrocnemius medialis - GM) of sprinters and endurance athletes by using localized dynamic 31 P-MRS. In addition, the respiratory parameters VO2 and VCO2 , as well as blood lactate concentrations, were monitored simultaneously to assess the effects of local metabolic adjustments in the loaded muscles on global physiological parameters. Besides noting obvious differences between the SOL and the GM muscles, we were also able to identify distinct physiological strategies in dealing with the exhaustive exercise by recruiting two athlete groups with opposing metabolic profiles. Endurance athletes tended to use the aerobic pathway in the metabolism of glucose, whereas sprinters produced a significantly higher peak concentration of lactate. These global findings go along with locally measured differences, especially in the main performer GM, with sprinters revealing a higher degree of acidification at the end of exercise (pH 6.29 ± 0.20 vs. 6.57 ± 0.21). Endurance athletes were able to partially recover their PCr stores during the exhaustive exercise and seemed to distribute their metabolic activity more consistently over both investigated muscles. In contrast, sprinters mainly stressed Type II muscle fibers, which corresponds more to their training orientation preferring the glycolytic energy supply pathway. In conclusion, we were able to analyze the relation between specific local metabolic processes in loaded muscles and typical global adaptation parameters, conventionally used to monitor the training status of athletes, in two cohorts with different sports orientations.
Collapse
Affiliation(s)
- Kevin Moll
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Philosophenweg 3, Jena, Germany
| | - Alexander Gussew
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Philosophenweg 3, Jena, Germany
| | - Maria Nisser
- Institute of Physiotherapy, Jena University Hospital - Friedrich Schiller University Jena, Jena, Germany
| | - Steffen Derlien
- Institute of Physiotherapy, Jena University Hospital - Friedrich Schiller University Jena, Jena, Germany
| | - Martin Krämer
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Philosophenweg 3, Jena, Germany
| | - Jürgen R Reichenbach
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Philosophenweg 3, Jena, Germany
| |
Collapse
|
13
|
Boss A, Heskamp L, Breukels V, Bains LJ, van Uden MJ, Heerschap A. Oxidative capacity varies along the length of healthy human tibialis anterior. J Physiol 2018; 596:1467-1483. [PMID: 29455454 DOI: 10.1113/jp275009] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Accepted: 02/12/2018] [Indexed: 11/08/2022] Open
Abstract
KEY POINTS During exercise skeletal muscles use the energy buffer phosphocreatine. The post-exercise recovery of phosphocreatine is a measure of the oxidative capacity of muscles and is traditionally assessed by 31 P magnetic resonance spectroscopy of a large tissue region, assuming homogeneous energy metabolism. To test this assumption, we collected spatially resolved spectra along the length of human tibialis anterior using a home-built array of 31 P detection coils, and observed a striking gradient in the recovery rate of phosphocreatine, decreasing along the proximo-distal axis of the muscle. A similar gradient along this muscle was observed in signal changes recorded by 1 H muscle functional MRI. These findings identify intra-muscular variation in the physiology of muscles in action and highlight the importance of localized sampling for any methodology investigating oxidative metabolism of this, and potentially other muscles. ABSTRACT The rate of phosphocreatine (PCr) recovery (kPCr ) after exercise, characterizing muscle oxidative capacity, is traditionally assessed with unlocalized 31 P magnetic resonance spectroscopy (MRS) using a single surface coil. However, because of intramuscular variation in fibre type and oxygen supply, kPCr may be non-uniform within muscles. We tested this along the length of the tibialis anterior (TA) muscle in 10 male volunteers. For this purpose, we employed a 3T MR system with a 31 P/1 H volume transmit coil combined with a home-built 31 P phased-array receive probe, consisting of five coil elements covering the TA muscle length. Mono-exponential kPCr was determined for all coil elements after 40 s of submaximal isometric dorsiflexion (SUBMAX) and incremental exercise to exhaustion (EXH). In addition, muscle functional MRI (1 H mfMRI) was performed using the volume coil after another 40 s of SUBMAX. A strong gradient in kPCr was observed along the TA (P < 0.001), being two times higher proximally vs. distally during SUBMAX and EXH. Statistical analysis showed that this gradient cannot be explained by pH variations. A similar gradient was seen in the slope of the initial post-exercise 1 H mfMRI signal change, which was higher proximally than distally in both the TA and the extensor digitorum longus (P < 0.001) and strongly correlated with kPCr . The pronounced differences along the TA in functional oxidative capacity identify regional variation in the physiological demand of this muscle during everyday activities and have implications for the bio-energetic assessment of interventions to modify its performance and of neuromuscular disorders involving the TA.
Collapse
Affiliation(s)
- Andreas Boss
- Department of Radiology and Nuclear Medicine, Radboud university medical center, Nijmegen, The Netherlands
| | - Linda Heskamp
- Department of Radiology and Nuclear Medicine, Radboud university medical center, Nijmegen, The Netherlands
| | - Vincent Breukels
- Department of Radiology and Nuclear Medicine, Radboud university medical center, Nijmegen, The Netherlands
| | - Lauren J Bains
- Donders Centre for Cognitive Neuroimaging, Radboud University, Nijmegen, The Netherlands
| | - Mark J van Uden
- Department of Radiology and Nuclear Medicine, Radboud university medical center, Nijmegen, The Netherlands
| | - Arend Heerschap
- Department of Radiology and Nuclear Medicine, Radboud university medical center, Nijmegen, The Netherlands
| |
Collapse
|
14
|
Valkovič L, Chmelík M, Krššák M. In-vivo 31P-MRS of skeletal muscle and liver: A way for non-invasive assessment of their metabolism. Anal Biochem 2017; 529:193-215. [PMID: 28119063 PMCID: PMC5478074 DOI: 10.1016/j.ab.2017.01.018] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 01/13/2017] [Accepted: 01/19/2017] [Indexed: 01/18/2023]
Abstract
In addition to direct assessment of high energy phosphorus containing metabolite content within tissues, phosphorus magnetic resonance spectroscopy (31P-MRS) provides options to measure phospholipid metabolites and cellular pH, as well as the kinetics of chemical reactions of energy metabolism in vivo. Even though the great potential of 31P-MR was recognized over 30 years ago, modern MR systems, as well as new, dedicated hardware and measurement techniques provide further opportunities for research of human biochemistry. This paper presents a methodological overview of the 31P-MR techniques that can be used for basic, physiological, or clinical research of human skeletal muscle and liver in vivo. Practical issues of 31P-MRS experiments and examples of potential applications are also provided. As signal localization is essential for liver 31P-MRS and is important for dynamic muscle examinations as well, typical localization strategies for 31P-MR are also described.
Collapse
Affiliation(s)
- Ladislav Valkovič
- High-field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria; Oxford Centre for Clinical Magnetic Resonance Research (OCMR), University of Oxford, Oxford, United Kingdom; Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia.
| | - Marek Chmelík
- High-field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria; Institute for Clinical Molecular MRI in Musculoskeletal System, Karl Landsteiner Society, Vienna, Austria
| | - Martin Krššák
- High-field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria; Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
15
|
Valkovič L, Chmelík M, Meyerspeer M, Gagoski B, Rodgers CT, Krššák M, Andronesi OC, Trattnig S, Bogner W. Dynamic 31 P-MRSI using spiral spectroscopic imaging can map mitochondrial capacity in muscles of the human calf during plantar flexion exercise at 7 T. NMR IN BIOMEDICINE 2016; 29:1825-1834. [PMID: 27862510 PMCID: PMC5132121 DOI: 10.1002/nbm.3662] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Revised: 09/19/2016] [Accepted: 09/28/2016] [Indexed: 05/06/2023]
Abstract
Phosphorus MRSI (31 P-MRSI) using a spiral-trajectory readout at 7 T was developed for high temporal resolution mapping of the mitochondrial capacity of exercising human skeletal muscle. The sensitivity and localization accuracy of the method was investigated in phantoms. In vivo performance was assessed in 12 volunteers, who performed a plantar flexion exercise inside a whole-body 7 T MR scanner using an MR-compatible ergometer and a surface coil. In five volunteers the knee was flexed (~60°) to shift the major workload from the gastrocnemii to the soleus muscle. Spiral-encoded MRSI provided 16-25 times faster mapping with a better point spread function than elliptical phase-encoded MRSI with the same matrix size. The inevitable trade-off for the increased temporal resolution was a reduced signal-to-noise ratio, but this was acceptable. The phosphocreatine (PCr) depletion caused by exercise at 0° knee angulation was significantly higher in both gastrocnemii than in the soleus (i.e. 64.8 ± 19.6% and 65.9 ± 23.6% in gastrocnemius lateralis and medialis versus 15.3 ± 8.4% in the soleus). Spiral-encoded 31 P-MRSI is a powerful tool for dynamic mapping of exercising muscle oxidative metabolism, including localized assessment of PCr concentrations, pH and maximal oxidative flux with high temporal and spatial resolution.
Collapse
Affiliation(s)
- Ladislav Valkovič
- High‐Field MR CentreMedical University of ViennaViennaAustria
- Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria
- Christian Doppler Laboratory for Clinical Molecular MR ImagingViennaAustria
- Department of Imaging Methods, Institute of Measurement ScienceSlovak Academy of SciencesBratislavaSlovakia
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR)University of OxfordOxfordUK
| | - Marek Chmelík
- High‐Field MR CentreMedical University of ViennaViennaAustria
- Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria
- Christian Doppler Laboratory for Clinical Molecular MR ImagingViennaAustria
| | - Martin Meyerspeer
- High‐Field MR CentreMedical University of ViennaViennaAustria
- Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Borjan Gagoski
- Fetal Neonatal Neuroimaging and Developmental Science CenterBoston Children's HospitalBostonMassachusettsUSA
| | - Christopher T. Rodgers
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR)University of OxfordOxfordUK
| | - Martin Krššák
- High‐Field MR CentreMedical University of ViennaViennaAustria
- Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria
- Christian Doppler Laboratory for Clinical Molecular MR ImagingViennaAustria
- Division of Endocrinology and Metabolism, Department of Internal Medicine IIIMedical University of ViennaViennaAustria
| | - Ovidiu C. Andronesi
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General HospitalHarvard Medical SchoolBostonMassachusettsUSA
| | - Siegfried Trattnig
- High‐Field MR CentreMedical University of ViennaViennaAustria
- Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria
- Christian Doppler Laboratory for Clinical Molecular MR ImagingViennaAustria
| | - Wolfgang Bogner
- High‐Field MR CentreMedical University of ViennaViennaAustria
- Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria
- Christian Doppler Laboratory for Clinical Molecular MR ImagingViennaAustria
| |
Collapse
|