1
|
Shang Y, Theilenberg S, Gajdošík M, Schreiber LM, Juchem C. High resolution simulation and measurement demonstrate oscillatory spatiotemporal B 0 fluctuations across the human cardiac cycle. Magn Reson Med 2024; 91:91-104. [PMID: 37598417 DOI: 10.1002/mrm.29831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 07/12/2023] [Accepted: 07/28/2023] [Indexed: 08/22/2023]
Abstract
PURPOSE Functional cardiac MRI scans employing balanced steady-state free precession sequences suffer from dark band artifacts in the myocardium due to B0 inhomogeneity. We recently introduced a novel method for the theoretical derivation of B0 distributions in the human heart. This study aims to simulate the B0 distributions in the heart across the cardiac cycle using structural MR images and validate the simulations via in vivo measured cardiac phase-specific B0 maps on the same subjects at 3T. METHODS Cardiac phase-specific B0 field maps were acquired from eight healthy subjects at 3T. B0 conditions were simulated based on tissue masks created from the cardiac-phase specific structural images from the in vivo B0 map scan and anatomical images from a thoracic MRI scan, adopting our recently published approach. The simulations and in vivo measurements were compared by calculating the spatial correlation of their B0 distributions and temporal correlation of the derived spherical harmonic coefficients throughout the cardiac cycle. RESULTS The spatial comparison of B0 maps between the simulation and in vivo measurement indicates an overall average correlation coefficient of 0.91 across the cardiac cycle in all subjects. Both groups show consistent high-level B0 patterns. Temporal variations of B0 conditions exhibit sinusoidal characteristics and are strongly correlated between simulation and in vivo. CONCLUSION Theoretical simulations employing regional anatomical features were validated by direct in vivo B0 mapping in the same subjects. The spatial B0 condition throughout the cardiac cycle exhibits oscillatory characteristics due to structural distortions of cardiac motion.
Collapse
Affiliation(s)
- Yun Shang
- Department of Biomedical Engineering, Columbia University in the City of New York, New York, New York, USA
| | - Sebastian Theilenberg
- Department of Biomedical Engineering, Columbia University in the City of New York, New York, New York, USA
| | - Martin Gajdošík
- Department of Biomedical Engineering, Columbia University in the City of New York, New York, New York, USA
| | - Laura M Schreiber
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure Center, University Hospital Wuerzburg, Wuerzburg, Germany
- Department of Cardiovascular Imaging, Comprehensive Heart Failure Center, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Christoph Juchem
- Department of Biomedical Engineering, Columbia University in the City of New York, New York, New York, USA
- Department of Radiology, Columbia University in the City of New York, New York, New York, USA
| |
Collapse
|
2
|
Nurzed B, Kuehne A, Aigner CS, Schmitter S, Niendorf T, Eigentler TW. Radiofrequency antenna concepts for human cardiac MR at 14.0 T. MAGMA (NEW YORK, N.Y.) 2023; 36:257-277. [PMID: 36920549 PMCID: PMC10140016 DOI: 10.1007/s10334-023-01075-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 02/23/2023] [Accepted: 02/27/2023] [Indexed: 04/28/2023]
Abstract
OBJECTIVE To examine the feasibility of human cardiac MR (CMR) at 14.0 T using high-density radiofrequency (RF) dipole transceiver arrays in conjunction with static and dynamic parallel transmission (pTx). MATERIALS AND METHODS RF arrays comprised of self-grounded bow-tie (SGBT) antennas, bow-tie (BT) antennas, or fractionated dipole (FD) antennas were used in this simulation study. Static and dynamic pTx were applied to enhance transmission field (B1+) uniformity and efficiency in the heart of the human voxel model. B1+ distribution and maximum specific absorption rate averaged over 10 g tissue (SAR10g) were examined at 7.0 T and 14.0 T. RESULTS At 14.0 T static pTx revealed a minimum B1+ROI efficiency of 0.91 μT/√kW (SGBT), 0.73 μT/√kW (BT), and 0.56 μT/√kW (FD) and maximum SAR10g of 4.24 W/kg, 1.45 W/kg, and 2.04 W/kg. Dynamic pTx with 8 kT points indicate a balance between B1+ROI homogeneity (coefficient of variation < 14%) and efficiency (minimum B1+ROI > 1.11 µT/√kW) at 14.0 T with a maximum SAR10g < 5.25 W/kg. DISCUSSION MRI of the human heart at 14.0 T is feasible from an electrodynamic and theoretical standpoint, provided that multi-channel high-density antennas are arranged accordingly. These findings provide a technical foundation for further explorations into CMR at 14.0 T.
Collapse
Affiliation(s)
- Bilguun Nurzed
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Robert Rössle Strasse 10, 13125, Berlin, Germany
| | | | | | | | - Thoralf Niendorf
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Robert Rössle Strasse 10, 13125, Berlin, Germany.
- MRI.TOOLS GmbH, Berlin, Germany.
- Experimental and Clinical Research Center (ECRC), a joint cooperation between the Charité Medical Faculty and the Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.
| | - Thomas Wilhelm Eigentler
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Robert Rössle Strasse 10, 13125, Berlin, Germany
- Chair of Medical Engineering, Technische Universität Berlin, Berlin, Germany
| |
Collapse
|
3
|
Shang Y, Theilenberg S, Terekhov M, Mattar W, Peng B, Jambawalikar SR, Schreiber LM, Juchem C. High-resolution simulation of B 0 field conditions in the human heart from segmented computed tomography images. NMR IN BIOMEDICINE 2022; 35:e4739. [PMID: 35393706 DOI: 10.1002/nbm.4739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 04/04/2022] [Accepted: 04/05/2022] [Indexed: 06/14/2023]
Abstract
B0 inhomogeneity leads to imaging artifacts in cardiac magnetic resonance imaging (MRI), in particular dark band artifacts with steady-state free precession pulse sequences. The limited spatial resolution of MR-derived in vivo B0 maps and the lack of population data prevent systematic analysis of the problem at hand and the development of optimized B0 shim strategies. We used readily available clinical computed tomography (CT) images to simulate the B0 conditions in the human heart at high spatial resolution. Calculated B0 fields showed consistency with MRI-based B0 measurements. The B0 maps for both the simulations and in vivo measurements showed local field inhomogeneities in the vicinity of lung tips with dominant Z3 spherical harmonic terms in the field distribution. The presented simulation approach allows for the derivation of B0 field conditions at high spatial resolution from CT images and enables the development of subject- and population-specific B0 shim strategies for the human heart.
Collapse
Affiliation(s)
- Yun Shang
- Department of Biomedical Engineering, Columbia University in the City of New York, New York, New York, USA
| | - Sebastian Theilenberg
- Department of Biomedical Engineering, Columbia University in the City of New York, New York, New York, USA
| | - Maxim Terekhov
- Section of Medical Physics, Department of Radiology, Mainz University Hospital, Mainz, Germany
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure Center (CHFC), Würzburg, Germany
| | - Wolfram Mattar
- Section of Medical Physics, Department of Radiology, Mainz University Hospital, Mainz, Germany
| | - Boyu Peng
- Department of Radiology, Columbia University in the City of New York, New York, New York, USA
| | - Sachin R Jambawalikar
- Department of Biomedical Engineering, Columbia University in the City of New York, New York, New York, USA
- Department of Radiology, Columbia University in the City of New York, New York, New York, USA
| | - Laura M Schreiber
- Section of Medical Physics, Department of Radiology, Mainz University Hospital, Mainz, Germany
- Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure Center (CHFC), Würzburg, Germany
| | - Christoph Juchem
- Department of Biomedical Engineering, Columbia University in the City of New York, New York, New York, USA
- Department of Radiology, Columbia University in the City of New York, New York, New York, USA
| |
Collapse
|
4
|
Ku MC, Kober F, Lai YC, Pohlmann A, Qadri F, Bader M, Carrier L, Niendorf T. Cardiovascular magnetic resonance detects microvascular dysfunction in a mouse model of hypertrophic cardiomyopathy. J Cardiovasc Magn Reson 2021; 23:63. [PMID: 34053450 PMCID: PMC8166121 DOI: 10.1186/s12968-021-00754-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 04/06/2021] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Hypertrophic cardiomyopathy (HCM) related myocardial vascular remodelling may lead to the reduction of myocardial blood supply and a subsequent progressive loss of cardiac function. This process has been difficult to observe and thus their connection remains unclear. Here we used non-invasive myocardial blood flow sensitive CMR to show an impairment of resting myocardial perfusion in a mouse model of naturally occurring HCM. METHODS We used a mouse model (DBA/2 J; D2 mouse strain) that spontaneously carries variants in the two most susceptible HCM genes-Mybpc3 and Myh7 and bears the key features of human HCM. The C57BL/6 J (B6) was used as a reference strain. Mice with either B6 or D2 backgrounds (male: n = 4, female: n = 4) underwent cine-CMR for functional assessment at 9.4 T. Left ventricular (LV) wall thickness was measured in end diastolic phase by cine-CMR. Quantitative myocardial perfusion maps (male: n = 5, female: n = 5 in each group) were acquired from arterial spin labelling (cine ASL-CMR) at rest. Myocardial perfusion values were measured by delineating different regions of interest based on the LV segmentation model in the mid ventricle of the LV myocardium. Directly after the CMR, the mouse hearts were removed for histological assessments to confirm the incidence of myocardial interstitial fibrosis (n = 8 in each group) and small vessel remodelling such as vessel density (n = 6 in each group) and perivascular fibrosis (n = 8 in each group). RESULTS LV hypertrophy was more pronounced in D2 than in B6 mice (male: D2 LV wall thickness = 1.3 ± 0.1 mm vs B6 LV wall thickness = 1.0 ± 0.0 mm, p < 0.001; female: D2 LV wall thickness = 1.0 ± 0.1 mm vs B6 LV wall thickness = 0.8 ± 0.1 mm, p < 0.01). The resting global myocardial perfusion (myocardial blood flow; MBF) was lower in D2 than in B6 mice (end-diastole: D2 MBFglobal = 7.5 ± 0.6 vs B6 MBFglobal = 9.3 ± 1.6 ml/g/min, p < 0.05; end-systole: D2 MBFglobal = 6.6 ± 0.8 vs B6 MBFglobal = 8.2 ± 2.6 ml/g/min, p < 0.01). This myocardial microvascular dysfunction was observed and associated with a reduction in regional MBF, mainly in the interventricular septal and inferior areas of the myocardium. Immunofluorescence revealed a lower number of vessel densities in D2 than in B6 (D2 capillary = 31.0 ± 3.8% vs B6 capillary = 40.7 ± 4.6%, p < 0.05). Myocardial collagen volume fraction (CVF) was significantly higher in D2 LV versus B6 LV mice (D2 CVF = 3.7 ± 1.4% vs B6 CVF = 1.7 ± 0.7%, p < 0.01). Furthermore, a higher ratio of perivascular fibrosis (PFR) was found in D2 than in B6 mice (D2 PFR = 2.3 ± 1.0%, B6 PFR = 0.8 ± 0.4%, p < 0.01). CONCLUSIONS Our work describes an imaging marker using cine ASL-CMR with a potential to monitor vascular and myocardial remodelling in HCM.
Collapse
Affiliation(s)
- Min-Chi Ku
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Robert-Rössle Strasse 10, 13125, Berlin, Germany.
- DZHK (German Centre for Cardiovascular Research), Partner site Berlin, Berlin, Germany.
| | - Frank Kober
- Centre de Résonance Magnétique Biologique et Médicale (CRMBM), Aix-Marseille University, CNRS, Marseille, France
| | - Yi-Ching Lai
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Robert-Rössle Strasse 10, 13125, Berlin, Germany
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Robert-Rössle Strasse 10, 13125, Berlin, Germany
| | - Fatimunnisa Qadri
- Molecular Biology of Peptide Hormones, Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
| | - Michael Bader
- DZHK (German Centre for Cardiovascular Research), Partner site Berlin, Berlin, Germany
- Molecular Biology of Peptide Hormones, Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
| | - Lucie Carrier
- Department of Experimental Pharmacology and Toxicology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner site Hamburg/Kiel/Lübeck, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Robert-Rössle Strasse 10, 13125, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner site Berlin, Berlin, Germany
- Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Berlin, Germany
| |
Collapse
|
5
|
Herrmann CJJ, Els A, Boehmert L, Periquito J, Eigentler TW, Millward JM, Waiczies S, Kuchling J, Paul F, Niendorf T. Simultaneous T 2 and T 2 ∗ mapping of multiple sclerosis lesions with radial RARE-EPI. Magn Reson Med 2021; 86:1383-1402. [PMID: 33951214 DOI: 10.1002/mrm.28811] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 03/26/2021] [Accepted: 03/26/2021] [Indexed: 12/26/2022]
Abstract
PURPOSE The characteristic MRI features of multiple sclerosis (MS) lesions make it conceptually appealing to pursue parametric mapping techniques that support simultaneous generation of quantitative maps of 2 or more MR contrast mechanisms. We present a modular rapid acquisition with relaxation enhancement (RARE)-EPI hybrid that facilitates simultaneous T2 and T 2 ∗ mapping (2in1-RARE-EPI). METHODS In 2in1-RARE-EPI the first echoes in the echo train are acquired with a RARE module, later echoes are acquired with an EPI module. To define the fraction of echoes covered by the RARE and EPI module, an error analysis of T2 and T 2 ∗ was conducted with Monte Carlo simulations. Radial k-space (under)sampling was implemented for acceleration (R = 2). The feasibility of 2in1-RARE-EPI for simultaneous T2 and T 2 ∗ mapping was examined in a phantom study mimicking T2 and T 2 ∗ relaxation times of the brain. For validation, 2in1-RARE-EPI was benchmarked versus multi spin-echo (MSE) and multi gradient-echo (MGRE) techniques. The clinical applicability of 2in1-RARE-EPI was demonstrated in healthy subjects and MS patients. RESULTS There was a good agreement between T2 / T 2 ∗ values derived from 2in1-RARE-EPI and T2 / T 2 ∗ reference values obtained from MSE and MGRE in both phantoms and healthy subjects. In patients, MS lesions in T2 and T 2 ∗ maps deduced from 2in1-RARE-EPI could be just as clearly delineated as in reference maps calculated from MSE/MGRE. CONCLUSION This work demonstrates the feasibility of radially (under)sampled 2in1-RARE-EPI for simultaneous T2 and T 2 ∗ mapping in MS patients.
Collapse
Affiliation(s)
- Carl J J Herrmann
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Department of Physics, Humboldt University of Berlin, Berlin, Germany
| | - Antje Els
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Laura Boehmert
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Joao Periquito
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Thomas Wilhelm Eigentler
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Chair of Medical Engineering, Technical University of Berlin, Berlin, Germany
| | - Jason M Millward
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Sonia Waiczies
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Joseph Kuchling
- Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, Berlin, Germany.,NeuroCure Clinical Research Center, Charité-Universitätsmedizin, Berlin, Germany.,Department of Neurology, Charité-Universitätsmedizin, Berlin, Germany
| | - Friedemann Paul
- Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, Berlin, Germany.,NeuroCure Clinical Research Center, Charité-Universitätsmedizin, Berlin, Germany.,Department of Neurology, Charité-Universitätsmedizin, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, Berlin, Germany
| |
Collapse
|
6
|
Jeon S, Kim S, Ha S, Lee S, Kim E, Kim SY, Park SH, Jeon JH, Kim SW, Moon C, Nelson BJ, Kim JY, Yu SW, Choi H. Magnetically actuated microrobots as a platform for stem cell transplantation. Sci Robot 2021; 4:4/30/eaav4317. [PMID: 33137727 DOI: 10.1126/scirobotics.aav4317] [Citation(s) in RCA: 130] [Impact Index Per Article: 43.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Accepted: 04/25/2019] [Indexed: 12/11/2022]
Abstract
Magnetic microrobots were developed for three-dimensional culture and the precise delivery of stem cells in vitro, ex vivo, and in vivo. Hippocampal neural stem cells attached to the microrobots proliferated and differentiated into astrocytes, oligodendrocytes, and neurons. Moreover, microrobots were used to transport colorectal carcinoma cancer cells to tumor microtissue in a body-on-a-chip, which comprised an in vitro liver-tumor microorgan network. The microrobots were also controlled in a mouse brain slice and rat brain blood vessel. Last, microrobots carrying mesenchymal stem cells derived from human nose were manipulated inside the intraperitoneal cavity of a nude mouse. The results indicate the potential of microrobots for the culture and delivery of stem cells.
Collapse
Affiliation(s)
- Sungwoong Jeon
- Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu 42988, South Korea.,DGIST-ETH Microrobotics Research Center, DGIST, Daegu 42988, South Korea
| | - Sangwon Kim
- Institute of Robotic and Intelligent System (IRIS), ETH, Zurich 8092, Switzerland
| | - Shinwon Ha
- Department of Brain and Cognitive Sciences, DGIST, Daegu 42988, South Korea
| | - Seungmin Lee
- Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu 42988, South Korea.,DGIST-ETH Microrobotics Research Center, DGIST, Daegu 42988, South Korea
| | - Eunhee Kim
- Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu 42988, South Korea.,DGIST-ETH Microrobotics Research Center, DGIST, Daegu 42988, South Korea
| | - So Yeun Kim
- Department of Brain and Cognitive Sciences, DGIST, Daegu 42988, South Korea
| | - Sun Hwa Park
- Postech-Catholic Biomedical Engineering Institute, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Jung Ho Jeon
- Postech-Catholic Biomedical Engineering Institute, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Sung Won Kim
- Postech-Catholic Biomedical Engineering Institute, College of Medicine, The Catholic University of Korea, Seoul, South Korea.,Department of Otolaryngology-Head and Neck Surgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul 06591, South Korea
| | - Cheil Moon
- Department of Brain and Cognitive Sciences, DGIST, Daegu 42988, South Korea
| | - Bradley J Nelson
- Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu 42988, South Korea.,DGIST-ETH Microrobotics Research Center, DGIST, Daegu 42988, South Korea.,Institute of Robotic and Intelligent System (IRIS), ETH, Zurich 8092, Switzerland
| | - Jin-Young Kim
- Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu 42988, South Korea. .,DGIST-ETH Microrobotics Research Center, DGIST, Daegu 42988, South Korea
| | - Seong-Woon Yu
- Department of Brain and Cognitive Sciences, DGIST, Daegu 42988, South Korea.
| | - Hongsoo Choi
- Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu 42988, South Korea. .,DGIST-ETH Microrobotics Research Center, DGIST, Daegu 42988, South Korea
| |
Collapse
|
7
|
Ibrahim ESH, Arpinar VE, Muftuler LT, Stojanovska J, Nencka AS, Koch KM. Cardiac functional magnetic resonance imaging at 7T: Image quality optimization and ultra-high field capabilities. World J Radiol 2020; 12:231-246. [PMID: 33240463 PMCID: PMC7653183 DOI: 10.4329/wjr.v12.i10.231] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 09/27/2020] [Accepted: 10/14/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND 7T cardiac magnetic resonance imaging (MRI) introduces several advantages, as well as some limitations, compared to lower-field imaging. The capabilities of ultra-high field (UHF) MRI have not been fully exploited in cardiac functional imaging.
AIM To optimize 7T cardiac MRI functional imaging without the need for conducting B1 shimming or subject-specific tuning, which improves scan efficiency. In this study, we provide results from phantom and in vivo scans using a multi-channel transceiver modular coil.
METHODS We investigated the effects of adding a dielectric pad at different locations next to the imaged region of interest on improving image quality in subjects with different body habitus. We also investigated the effects of adjusting the imaging flip angle in cine and tagging sequences on improving image quality, B1 field homogeneity, signal-to-noise ratio (SNR), blood-myocardium contrast-to-noise ratio (CNR), and tagging persistence throughout the cardiac cycle.
RESULTS The results showed the capability of achieving improved image quality with high spatial resolution (0.75 mm × 0.75 mm × 2 mm), high temporal resolution (20 ms), and increased tagging persistence (for up to 1200 ms cardiac cycle duration) at 7T cardiac MRI after adjusting scan set-up and imaging parameters. Adjusting the imaging flip angle was essential for achieving optimal SNR and myocardium-to-blood CNR. Placing a dielectric pad at the anterior left position of the chest resulted in improved B1 homogeneity compared to other positions, especially in subjects with small chest size.
CONCLUSION Improved regional and global cardiac functional imaging can be achieved at 7T MRI through simple scan set-up adjustment and imaging parameter optimization, which would allow for more streamlined and efficient UHF cardiac MRI.
Collapse
Affiliation(s)
- El-Sayed H Ibrahim
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, United States
| | - V Emre Arpinar
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, United States
| | - L Tugan Muftuler
- Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, United States
| | - Jadranka Stojanovska
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, United States
| | - Andrew S Nencka
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, United States
| | - Kevin M Koch
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, United States
| |
Collapse
|
8
|
Ibrahim ESH, Arpinar VE, Muftuler LT, Stojanovska J, Nencka AS, Koch KM. Cardiac functional magnetic resonance imaging at 7T: Image quality optimization and ultra-high field capabilities. World J Radiol 2020. [DOI: 10.4329/wjr.v12.i10.229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
9
|
Hock M, Terekhov M, Stefanescu MR, Lohr D, Herz S, Reiter T, Ankenbrand M, Kosmala A, Gassenmaier T, Juchem C, Schreiber LM. B 0 shimming of the human heart at 7T. Magn Reson Med 2020; 85:182-196. [PMID: 32700791 DOI: 10.1002/mrm.28423] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 06/19/2020] [Accepted: 06/22/2020] [Indexed: 01/31/2023]
Abstract
PURPOSE Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio-temporal B0 -field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state-of-the-art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed. METHODS The spatial B0 -field distribution in the heart was analyzed as well as temporal B0 -field variations in the myocardium over the cardiac cycle. Different shim region-of-interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration-based B0 -field modeling. The role of third-order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase-specific shimming. RESULTS The strongest B0 -field inhomogeneities were observed in localized spots within the left-ventricular and right-ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy-driven shim region-of-interest selection allowed for improved B0 -field homogeneity compared with a standard shim region-of-interest cuboid. Third-order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0 -field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase-specific shimming was performed, and a shim term-by-term analysis revealed periodic variations of required currents. CONCLUSION Challenges in state-of-the-art B0 shimming of the human heart at 7 T were described. Cardiac phase-specific shimming strategies were found to be superior to vendor-supplied shimming.
Collapse
Affiliation(s)
- Michael Hock
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany
| | - Maxim Terekhov
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany
| | - Maria Roxana Stefanescu
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany
| | - David Lohr
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany
| | - Stefan Herz
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany.,Department of Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Theresa Reiter
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany.,Department of Internal Medicine I, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Markus Ankenbrand
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany
| | - Aleksander Kosmala
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany.,Department of Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Tobias Gassenmaier
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany.,Department of Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Wuerzburg, Germany
| | - Christoph Juchem
- Department of Biomedical Engineering, Columbia University, New York, New York, USA.,Department of Radiology, Columbia University, New York, New York, USA
| | - Laura Maria Schreiber
- Chair of Cellular and Molecular Imaging, Comprehensive Heart Failure Center (CHFC), University Hospital Wuerzburg, Wuerzburg, Germany
| |
Collapse
|
10
|
Juan YH, Huang PC, Lin G, Liu MH, Lin YC, Wang JJ, Ng KK, Cheung YC, Wang CH, Ng SH. Oxygen-sensitive T2* magnetic resonance imaging to correlate heart function and ischemic etiology of post-hospitalized chronic heart failure patients. Eur J Radiol 2020; 128:109036. [PMID: 32403031 DOI: 10.1016/j.ejrad.2020.109036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 03/24/2020] [Accepted: 04/22/2020] [Indexed: 10/24/2022]
Abstract
PURPOSE Myocardial oxygenation imaging is a field-of-interest but its clinical utility largely unexplored. We aimed to investigate the myocardial oxygenation status via T2* imaging and compared with the left ventricular ejection fraction (LVEF) in chronic heart failure (HF) patients after hospitalization. Also, we sought to compare the differences in myocardial oxygenation status among patients with ischemic HF, non-ischemic HF and controls. METHODS We prospectively enrolled 60 participants, comprising 20 HF patients with LVEF ≥ 50 % as the improved ejection fraction (HFIEF) group, 20 H F patients with ejection fraction <50 % as the reduced ejection fraction (HFREF) group, and 20 controls. Patients were also dichotomized into ischemic and non-ischemic subgroups. T2* values were compared across the study groups, and correlated with LVEF, myocardial scar distribution and quantity. RESULTS T2* values positively correlated with LVEF and were significantly lower in the HFREF group as compared with both HFIEF and controls (20.06 vs. 24.23; 20.06 vs. 26.32, respectively, both p < 0.05). Lower T2* values were observed in the HFREF group than the HFIEF group and the ischemic subgroup than the non-ischemic subgroup. No significant correlation existed between T2* value and the myocardial scar amounts in ischemic territory. CONCLUSIONS Oxygen-sensitive T2* measurements showed correlation with LVEF and ischemic etiology in chronic heart failure patients, while the ischemic HFREF patients appeared to be more vulnerable to myocardial oxygen reduction than other groups. T2* measurements may be clinically feasible in monitoring heart failure via myocardial oxygenation and lay the foundation for future studies in prediction heart failure recovery.
Collapse
Affiliation(s)
- Yu-Hsiang Juan
- Department of Medical Imaging and Intervention, Imaging Core Laboratory, Institute for Radiological Research, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taoyuan, 333, Taiwan; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Taoyuan and Chang Gung University, Taoyuan, 333, Taiwan; Clinical Metabolomics Core Laboratory, Chang Gung Memorial Hospital at Linkou, Taoyuan, 333, Taiwan
| | - Pei-Ching Huang
- Department of Medical Imaging and Intervention, Imaging Core Laboratory, Institute for Radiological Research, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taoyuan, 333, Taiwan
| | - Gigin Lin
- Department of Medical Imaging and Intervention, Imaging Core Laboratory, Institute for Radiological Research, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taoyuan, 333, Taiwan; Clinical Metabolomics Core Laboratory, Chang Gung Memorial Hospital at Linkou, Taoyuan, 333, Taiwan
| | - Min-Hui Liu
- Heart Failure Research Center, Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Keelung and Chang Gung University College of Medicine, Taoyuan, 20401, Taiwan; Department of Nursing, National Yang-Ming University, Taipei, 11221, Taiwan
| | - Yu-Ching Lin
- Department of Medical Imaging and Intervention, Imaging Core Laboratory, Institute for Radiological Research, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taoyuan, 333, Taiwan; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Keelung and Chang Gung University, 20401, Taiwan
| | - Jiun-Jie Wang
- Department of Medical Imaging and Intervention, Imaging Core Laboratory, Institute for Radiological Research, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taoyuan, 333, Taiwan
| | - Koon-Kwan Ng
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Keelung and Chang Gung University, 20401, Taiwan
| | - Yun-Chung Cheung
- Department of Medical Imaging and Intervention, Imaging Core Laboratory, Institute for Radiological Research, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taoyuan, 333, Taiwan
| | - Chao-Hung Wang
- Heart Failure Research Center, Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Keelung and Chang Gung University College of Medicine, Taoyuan, 20401, Taiwan.
| | - Shu-Hang Ng
- Department of Medical Imaging and Intervention, Imaging Core Laboratory, Institute for Radiological Research, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Taoyuan, 333, Taiwan.
| |
Collapse
|
11
|
Triadyaksa P, Oudkerk M, Sijens PE. Cardiac T 2 * mapping: Techniques and clinical applications. J Magn Reson Imaging 2019; 52:1340-1351. [PMID: 31837078 PMCID: PMC7687175 DOI: 10.1002/jmri.27023] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 11/25/2019] [Indexed: 12/12/2022] Open
Abstract
Cardiac T2* mapping is a noninvasive MRI method that is used to identify myocardial iron accumulation in several iron storage diseases such as hereditary hemochromatosis, sickle cell disease, and β‐thalassemia major. The method has improved over the years in terms of MR acquisition, focus on relative artifact‐free myocardium regions, and T2* quantification. Several improvement factors involved include blood pool signal suppression, the reproducibility of T2* measurement as affected by scanner hardware, and acquisition software. Regarding the T2* quantification, improvement factors include the applied curve‐fitting method with or without truncation of the signals acquired at longer echo times and whether or not T2* measurement focuses on multiple segmental regions or the midventricular septum only. Although already widely applied in clinical practice, data processing still differs between centers, contributing to measurement outcome variations. State of the art T2* measurement involves pixelwise quantification providing better spatial iron loading information than region of interest‐based quantification. Improvements have been proposed, such as on MR acquisition for free‐breathing mapping, the generation of fast mapping, noise reduction, automatic myocardial contour delineation, and different T2* quantification methods. This review deals with the pro and cons of different methods used to quantify T2* and generate T2* maps. The purpose is to recommend a combination of MR acquisition and T2* mapping quantification techniques for reliable outcomes in measuring and follow‐up of myocardial iron overload. The clinical application of cardiac T2* mapping for iron overload's early detection, monitoring, and treatment is addressed. The prospects of T2* mapping combined with different MR acquisition methods, such as cardiac T1 mapping, are also described. Level of Evidence: 4 Technical Efficacy Stage: 5 J. Magn. Reson. Imaging 2019.
Collapse
Affiliation(s)
- Pandji Triadyaksa
- University of Groningen, Groningen, The Netherlands.,Universitas Diponegoro, Department of Physics, Faculty of Science and Mathematics, Semarang, Indonesia
| | - Matthijs Oudkerk
- University of Groningen, Groningen, The Netherlands.,Institute for Diagnostic Accuracy, Groningen, The Netherlands
| | - Paul E Sijens
- University of Groningen, Groningen, The Netherlands.,University Medical Center Groningen, Department of Radiology, Groningen, The Netherlands
| |
Collapse
|
12
|
Erturk MA, Li X, Van de Moortele PF, Ugurbil K, Metzger GJ. Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions. Top Magn Reson Imaging 2019; 28:101-124. [PMID: 31188271 PMCID: PMC6587233 DOI: 10.1097/rmr.0000000000000202] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
Abstract
The potential value of ultrahigh field (UHF) magnetic resonance imaging (MRI) and spectroscopy to biomedical research and in clinical applications drives the development of technologies to overcome its many challenges. The increased difficulties of imaging the human torso compared with the head include its overall size, the dimensions and location of its anatomic targets, the increased prevalence and magnitude of physiologic effects, the limited availability of tailored RF coils, and the necessary transmit chain hardware. Tackling these issues involves addressing notoriously inhomogeneous transmit B1 (B1) fields, limitations in peak B1, larger spatial variations of the static magnetic field B0, and patient safety issues related to implants and local RF power deposition. However, as research institutions and vendors continue to innovate, the potential gains are beginning to be realized. Solutions overcoming the unique challenges associated with imaging the human torso are reviewed as are current studies capitalizing on the benefits of UHF in several anatomies and applications. As the field progresses, strategies associated with the RF system architecture, calibration methods, RF pulse optimization, and power monitoring need to be further integrated into the MRI systems making what are currently complex processes more streamlined. Meanwhile, the UHF MRI community must seize the opportunity to build upon what have been so far proof of principle and feasibility studies and begin to further explore the true impact in both research and the clinic.
Collapse
Affiliation(s)
- M Arcan Erturk
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN
| | | | | | | | | |
Collapse
|
13
|
Niendorf T, Schulz-Menger J, Paul K, Huelnhagen T, Ferrari VA, Hodge R. High Field Cardiac Magnetic Resonance Imaging: A Case for Ultrahigh Field Cardiac Magnetic Resonance. Circ Cardiovasc Imaging 2019; 10:CIRCIMAGING.116.005460. [PMID: 28611118 DOI: 10.1161/circimaging.116.005460] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Thoralf Niendorf
- From the Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (T.N., K.P., T.H., R.H.); DZHK (German Centre for Cardiovascular Research), partner site Berlin (T.N., J.S.-M.); Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (J.S.-M.); Department for Cardiology and Nephrology, HELIOS Clinic Berlin-Buch, Germany (J.S.-M.); and Division of Cardiovascular Medicine and Penn Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia (V.A.F.).
| | - Jeanette Schulz-Menger
- From the Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (T.N., K.P., T.H., R.H.); DZHK (German Centre for Cardiovascular Research), partner site Berlin (T.N., J.S.-M.); Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (J.S.-M.); Department for Cardiology and Nephrology, HELIOS Clinic Berlin-Buch, Germany (J.S.-M.); and Division of Cardiovascular Medicine and Penn Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia (V.A.F.)
| | - Katharina Paul
- From the Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (T.N., K.P., T.H., R.H.); DZHK (German Centre for Cardiovascular Research), partner site Berlin (T.N., J.S.-M.); Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (J.S.-M.); Department for Cardiology and Nephrology, HELIOS Clinic Berlin-Buch, Germany (J.S.-M.); and Division of Cardiovascular Medicine and Penn Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia (V.A.F.)
| | - Till Huelnhagen
- From the Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (T.N., K.P., T.H., R.H.); DZHK (German Centre for Cardiovascular Research), partner site Berlin (T.N., J.S.-M.); Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (J.S.-M.); Department for Cardiology and Nephrology, HELIOS Clinic Berlin-Buch, Germany (J.S.-M.); and Division of Cardiovascular Medicine and Penn Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia (V.A.F.)
| | - Victor A Ferrari
- From the Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (T.N., K.P., T.H., R.H.); DZHK (German Centre for Cardiovascular Research), partner site Berlin (T.N., J.S.-M.); Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (J.S.-M.); Department for Cardiology and Nephrology, HELIOS Clinic Berlin-Buch, Germany (J.S.-M.); and Division of Cardiovascular Medicine and Penn Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia (V.A.F.)
| | - Russell Hodge
- From the Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (T.N., K.P., T.H., R.H.); DZHK (German Centre for Cardiovascular Research), partner site Berlin (T.N., J.S.-M.); Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany (J.S.-M.); Department for Cardiology and Nephrology, HELIOS Clinic Berlin-Buch, Germany (J.S.-M.); and Division of Cardiovascular Medicine and Penn Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia (V.A.F.)
| |
Collapse
|
14
|
Chen BH, Shi RY, An DA, Wu R, Wu CW, Hu J, Manly A, Kaddurah H, He J, Pu J, Xu JR, Wu LM. BOLD cardiac MRI for differentiating reversible and irreversible myocardial damage in ST segment elevation myocardial infarction. Eur Radiol 2018; 29:951-962. [PMID: 29987418 DOI: 10.1007/s00330-018-5612-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 06/07/2018] [Accepted: 06/15/2018] [Indexed: 12/13/2022]
Abstract
OBJECTIVES BOLD imaging is a quantitative MRI technique allowing the evaluation of the balance between supply/demand in myocardial oxygenation and myocardial haemorrhage. We sought to investigate the ability of BOLD imaging to differentiate reversible from irreversible myocardial injury as well as the chronological progression of myocardial oxygenation after reperfusion in patients with ST segment elevation myocardial infarction (STEMI). METHODS Twenty-two patients (age, 60 ± 11 years; 77.3% male) with STEMI underwent cardiac MRIs on four occasions: on days 1, 3, 7 and 30 after reperfusion. BOLD MRI was obtained with a multi-echo turbo field echo (TFE) sequence on a 3-T scanner to assess myocardial oxygenation in MI. RESULTS T2* value in MI with intramyocardial haemorrhage (IMH) was the lowest (9.77 ± 3.29 ms), while that of the salvaged zone was the highest (33.97 ± 3.42 ms). T2* values in salvaged myocardium demonstrated a unimodal temporal pattern from days 1 (37.91 ± 2.23 ms) to 30 (30.68 ± 1.59 ms). T2* values in the MI regions were significantly lower than those in remote myocardium, although the trends in both were constant overall. There was a slightly positive correlation between T2* in MI regions and EF (Rho = 0.27, p < 0.05) or SV (Rho = 0.22, p = 0.04) and a slightly negative correlation between T2* in salvaged myocardium and LVEDV (Rho = - 0.23, p < 0.05). CONCLUSIONS BOLD MRI performed in post-STEMI patients allows accurate evaluation of myocardial damage severity and could differentiate reversible from irreversible myocardial injury. The increased T2* values may imply the pathophysiological mechanism of salvaged myocardium. BOLD MRI could represent a more accurate alternative to the other currently available options. KEY POINTS • Myocardial oxygenation and haemorrhage after myocardial infarction affect BOLD MRI values • BOLD MRI could be used to differentiate irreversible from reversible myocardial damage • Changed oxygenation implies the pathophysiological mechanism of salvaged myocardium.
Collapse
Affiliation(s)
- Bing-Hua Chen
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No.160 PuJian Road, Shanghai, 200127, People's Republic of China
| | - Ruo-Yang Shi
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No.160 PuJian Road, Shanghai, 200127, People's Republic of China
| | - Dong-Aolei An
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No.160 PuJian Road, Shanghai, 200127, People's Republic of China
| | - Rui Wu
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No.160 PuJian Road, Shanghai, 200127, People's Republic of China
| | - Chong-Wen Wu
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No.160 PuJian Road, Shanghai, 200127, People's Republic of China
| | - Jiani Hu
- Department of Radiology, Wayne State University, Detroit, MI, 48201, USA
| | - Amanda Manly
- Department of Radiology, Wayne State University, Detroit, MI, 48201, USA
| | - Hisham Kaddurah
- Department of Radiology, Wayne State University, Detroit, MI, 48201, USA
| | - Jie He
- Department of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, People's Republic of China
| | - Jun Pu
- Department of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, People's Republic of China
| | - Jian-Rong Xu
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No.160 PuJian Road, Shanghai, 200127, People's Republic of China.
| | - Lian-Ming Wu
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No.160 PuJian Road, Shanghai, 200127, People's Republic of China.
| |
Collapse
|
15
|
Chen BH, Wu R, An DA, Shi RY, Yao QY, Lu Q, Hu J, Jiang M, Deen J, Chandra A, Xu JR, Wu LM. Oxygenation-sensitive cardiovascular magnetic resonance in hypertensive heart disease with left ventricular myocardial hypertrophy and non-left ventricular myocardial hypertrophy: Insight from altered mechanics and cardiac BOLD imaging. J Magn Reson Imaging 2018; 48:1297-1306. [PMID: 29734491 DOI: 10.1002/jmri.26055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 04/02/2018] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND BOLD (blood oxygen level dependent) MRI can detect regional condition of myocardial oxygen supply and demand by means of paramagnetic properties. PURPOSE Noninvasive assessment of myocardial oxygenation by BOLD MRI in hypertensive patients with hypertension (HTN) left ventricular myocardial hypertrophy (LVMH) and HTN non-LVMH and its correlation with myocardial mechanics were performed. STUDY TYPE Prospective. POPULATION Twenty patients with HTN LVMH, 21 patients with HTN non-LVMH, and 23 normotensive controls were enrolled. FIELD STRENGTH/SEQUENCE Cine imaging, T2* and T1 mapping sequences were achieved at 3.0T. ASSESSMENT Dedicated T1 mapping, T2*, and cine imaging analysis were performed by two radiologists using cvi42. STATISTICAL TESTS One-way analysis of variance, Kruskal-Wallis test, Bland-Altman analysis, Pearson's correlation coefficient, Spearman's rank correlation. RESULTS T2* values of HTN LVMH group were significantly lower versus the controls (23.78 ± 3.09 versus 30.77 ± 2.71; P < 0.001) and HTN non-LVMH group (23.78 ± 3.09 versus 28.64 ± 4.23; P < 0.001). Left ventricular peak circumferential strain were reduced in HTN LVMH patients compared with other two groups (-11.32 [-15.64, -10.3], -16.78 [-19.35, -15.34], and -19.73 [-20.57, -18.73]; P < 0.05); and longitudinal strain of HTN LVMH patients were lower than other two groups (-11.31 ± 2.91, -15.1 ± 3.06, and -18.85 ± 1.85; P < 0.05); radial strain of HTN LVMH patients were also lower than other two groups (25.03 ± 16, 40.95 ± 17.5 and 47.9 ± 10.23; P < 0.05). Extracellular volume correlated with peak circumferential, longitudinal, and radial strain (spearman rho = 0.6, 0.64, and -0.69; P < 0.05), respectively; T2* negatively correlated with peak circumferential and longitudinal strain (spearman rho = -0.43 and -0.49; P < 0.05), respectively. Patients with lower T2* values had significant decreases in myocardial mechanics (P < 0.05). DATA CONCLUSION HTN LVMH patients have both impaired myocardial mechanics and decreased T2* values compared with HTN non-LVMH and normotensive groups. BOLD MRI could provide a feasible assessment modality for detecting altered T2* due to the change of de-oxygenated hemoglobin and hence to the change of signal intensity in oxygenation-sensitive images. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1297-1306.
Collapse
Affiliation(s)
- Bing-Hua Chen
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Rui Wu
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Dong-Aolei An
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Ruo-Yang Shi
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Qiu-Ying Yao
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Qing Lu
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jiani Hu
- Department of Radiology, Wayne State University, Detroit, Michigan, USA
| | - Meng Jiang
- Department of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - James Deen
- Department of Radiology, Wayne State University, Detroit, Michigan, USA
| | - Ankush Chandra
- Department of Radiology, Wayne State University, Detroit, Michigan, USA
| | - Jian-Rong Xu
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Lian-Ming Wu
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
16
|
Huelnhagen T, Ku MC, Reimann HM, Serradas Duarte T, Pohlmann A, Flemming B, Seeliger E, Eichhorn C, A Ferrari V, Prothmann M, Schulz-Menger J, Niendorf T. Myocardial Effective Transverse Relaxation Time T 2* is Elevated in Hypertrophic Cardiomyopathy: A 7.0 T Magnetic Resonance Imaging Study. Sci Rep 2018; 8:3974. [PMID: 29507338 PMCID: PMC5838254 DOI: 10.1038/s41598-018-22439-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Accepted: 02/19/2018] [Indexed: 12/18/2022] Open
Abstract
Hypertrophic cardiomyopathy (HCM) is the most common genetic disease of the myocardium and bares the risk of progression to heart failure or sudden cardiac death. Identifying patients at risk remains an unmet need. Recognizing the dependence of microscopic susceptibility on tissue microstructure and on cardiac macromorphology we hypothesized that myocardial T2* might be altered in HCM patients compared to healthy controls. To test this hypothesis, myocardial T2*-mapping was conducted at 7.0 Tesla to enhance T2*-contrast. 2D CINE T2*-mapping was performed in healthy controls and HCM patients. To ensure that T2* is not dominated by macroscopic magnetic field inhomogeneities, volume selective B0 shimming was applied. T2* changes in the interventricular septum across the cardiac cycle were analyzed together with left ventricular radius and ventricular septal wall thickness. The results show that myocardial T2* is elevated throughout the cardiac cycle in HCM patients compared to healthy controls. A mean septal T2* = 13.7 ± 1.1 ms (end-systole: T2*,systole = 15.0 ± 2.1, end-diastole: T2*,diastole = 13.4 ± 1.3 ms, T2*,systole/T2*,diastole ratio = 1.12) was observed in healthy controls. For HCM patients a mean septal T2* = 17.4 ± 1.4 ms (end-systole: T2*,systole = 17.7 ± 1.2 ms, end-diastole: T2*,diastole = 16.2 ± 2.5 ms, T2*,systole/T2*,diastole ratio = 1.09) was found. Our preliminary results provide encouragement that assessment of T2* and its changes across the cardiac cycle may benefit myocardial tissue characterization in HCM.
Collapse
Affiliation(s)
- Till Huelnhagen
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Min-Chi Ku
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), partner site, Berlin, Germany
| | - Henning Matthias Reimann
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Teresa Serradas Duarte
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Bert Flemming
- Institute of Vegetative Physiology, Charité University Medicine, Berlin, Germany
| | - Erdmann Seeliger
- Institute of Vegetative Physiology, Charité University Medicine, Berlin, Germany
| | - Christina Eichhorn
- Statistical Sciences, Department of Information Technology, Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Victor A Ferrari
- Division of Cardiovascular Medicine and Penn Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
| | - Marcel Prothmann
- DZHK (German Centre for Cardiovascular Research), partner site, Berlin, Germany
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, Berlin, Germany
| | - Jeanette Schulz-Menger
- DZHK (German Centre for Cardiovascular Research), partner site, Berlin, Germany
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.
- DZHK (German Centre for Cardiovascular Research), partner site, Berlin, Germany.
- Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine, Berlin, Germany.
| |
Collapse
|
17
|
Pohlmann A, Cantow K, Huelnhagen T, Grosenick D, Dos Santos Periquito J, Boehmert L, Gladytz T, Waiczies S, Flemming B, Seeliger E, Niendorf T. Experimental MRI Monitoring of Renal Blood Volume Fraction Variations En Route to Renal Magnetic Resonance Oximetry. ACTA ACUST UNITED AC 2017; 3:188-200. [PMID: 30042981 PMCID: PMC6024389 DOI: 10.18383/j.tom.2017.00012] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Diagnosis of early-stage acute kidney injury (AKI) will benefit from a timely identification of local tissue hypoxia. Renal tissue hypoxia is an early feature in AKI pathophysiology, and renal oxygenation is increasingly being assessed through T2*-weighted magnetic resonance imaging (MRI). However, changes in renal blood volume fraction (BVf) confound renal T2*. The aim of this study was to assess the feasibility of intravascular contrast-enhanced MRI for monitoring renal BVf during physiological interventions that are concomitant with variations in BVf and to explore the possibility of correcting renal T2* for BVf variations. A dose-dependent study of the contrast agent ferumoxytol was performed in rats. BVf was monitored throughout short-term occlusion of the renal vein, which is known to markedly change renal blood partial pressure of O2 and BVf. BVf calculated from MRI measurements was used to estimate oxygen saturation of hemoglobin (SO2). BVf and SO2 were benchmarked against cortical data derived from near-infrared spectroscopy. As estimated from magnetic resonance parametric maps of T2 and T2*, BVf was shown to increase, whereas SO2 was shown to decline during venous occlusion (VO). This observation could be quantitatively reproduced in test–retest scenarios. Changes in BVf and SO2 were in good agreement with data obtained from near-infrared spectroscopy. Our findings provide motivation to advance multiparametric MRI for studying AKIs, with the ultimate goal of translating MRI-based renal BVf mapping into clinical practice en route noninvasive renal magnetic resonance oximetry as a method of assessing AKI and progression to chronic damage.
Collapse
Affiliation(s)
- Andreas Pohlmann
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Kathleen Cantow
- Institute of Physiology and Center for Cardiovascular Research, Charité - Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany
| | - Till Huelnhagen
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Dirk Grosenick
- Physikalisch-Technische-Bundesanstalt (PTB), Berlin, Germany
| | - Joāo Dos Santos Periquito
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Laura Boehmert
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Thomas Gladytz
- Physikalisch-Technische-Bundesanstalt (PTB), Berlin, Germany
| | - Sonia Waiczies
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany
| | - Bert Flemming
- Institute of Physiology and Center for Cardiovascular Research, Charité - Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany
| | - Erdmann Seeliger
- Institute of Physiology and Center for Cardiovascular Research, Charité - Universitätsmedizin Berlin, Campus Charité Mitte, Berlin, Germany
| | - Thoralf Niendorf
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany.,Experimental and Clinical Research Center, Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany; and.,Deutsches Zentrum für Herz- Kreislauf-Forschung (DZHK; German Centre for Cardiovascular Research), Berlin, Germany
| |
Collapse
|
18
|
Kording F, Ruprecht C, Schoennagel B, Fehrs K, Yamamura J, Adam G, Goebel J, Nassenstein K, Maderwald S, Quick H, Kraff O. Doppler ultrasound triggering for cardiac MRI at 7T. Magn Reson Med 2017; 80:239-247. [DOI: 10.1002/mrm.27032] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 10/09/2017] [Accepted: 11/13/2017] [Indexed: 01/31/2023]
Affiliation(s)
- F. Kording
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine; University Medical Center Hamburg-Eppendorf; Hamburg Germany
| | - C. Ruprecht
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine; University Medical Center Hamburg-Eppendorf; Hamburg Germany
| | - B. Schoennagel
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine; University Medical Center Hamburg-Eppendorf; Hamburg Germany
| | - K. Fehrs
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine; University Medical Center Hamburg-Eppendorf; Hamburg Germany
| | - J. Yamamura
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine; University Medical Center Hamburg-Eppendorf; Hamburg Germany
| | - G. Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine; University Medical Center Hamburg-Eppendorf; Hamburg Germany
| | - J. Goebel
- Erwin L. Hahn Institute for Magnetic Resonance Imaging; University Duisburg-Essen; Essen Germany
- Department of Diagnostic and Interventional Radiology and Neuroradiology; University Hospital, University Duisburg-Essen; Essen Germany
| | - K. Nassenstein
- Department of Diagnostic and Interventional Radiology and Neuroradiology; University Hospital, University Duisburg-Essen; Essen Germany
| | - S. Maderwald
- Erwin L. Hahn Institute for Magnetic Resonance Imaging; University Duisburg-Essen; Essen Germany
| | - H.H. Quick
- Erwin L. Hahn Institute for Magnetic Resonance Imaging; University Duisburg-Essen; Essen Germany
- High Field and Hybrid MR Imaging; University Hospital, University Duisburg-Essen; Essen Germany
| | - O. Kraff
- Erwin L. Hahn Institute for Magnetic Resonance Imaging; University Duisburg-Essen; Essen Germany
| |
Collapse
|