Solomakha GA, Glang F, Bosch D, Steffen T, Scheffler K, Avdievich NI. Dynamic parallel imaging at 9.4 T using reconfigurable receive coaxial dipoles. NMR IN BIOMEDICINE 2024; 37:e5118. [PMID: 38342102 DOI: 10.1002/nbm.5118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 01/09/2024] [Accepted: 01/17/2024] [Indexed: 02/13/2024]
Abstract
Parallel imaging is one of the key MRI technologies that allow reduction of image acquisition time. However, the parallel imaging reconstruction commonly leads to a signal-to-noise ratio (SNR) drop evaluated using a so-called geometrical factor (g-factor). The g-factor is minimized by increasing the number of array elements and their spatial diversity. At the same time, increasing the element count requires a decrease in their size. This may lead to insufficient coil loading, an increase in the relative noise contribution from the RF coil itself, and hence SNR reduction. Previously, instead of increasing the channel number, we introduced the concept of electronically switchable time-varying sensitivities, which was shown to improve parallel imaging performance. In this approach, each reconfigurable receive element supports two spatially distinct sensitivity profiles. In this work, we developed and evaluated a novel eight-element human head receive-only reconfigurable coaxial dipole array for human head imaging at 9.4 T. In contrast to the previously reported reconfigurable dipole array, the new design does not include direct current (DC) control wires connected directly to the dipoles. The coaxial cable itself is used to deliver DC voltage to the PIN diodes located at the ends of the antennas. Thus, the novel reconfigurable coaxial dipole design opens a way to scale the dynamic parallel imaging up to a realistic number of channels, that is, 32 and above. The novel array was optimized and tested experimentally, including in vivo studies. It was found that dynamic sensitivity switching provided an 8% lower mean and 33% lower maximum g-factor (for Ry × Rz = 2 × 2 acceleration) compared with conventional static sensitivities.
Collapse
Affiliation(s)
- Georgiy A Solomakha
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Felix Glang
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Dario Bosch
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany
| | - Theodor Steffen
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Klaus Scheffler
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany
| | - Nikolai I Avdievich
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| |
Collapse
|
2
|
Solomakha GA, Bosch D, Glang F, Scheffler K, Avdievich NI. Evaluation of coaxial dipole antennas as transceiver elements of human head array for ultra-high field MRI at 9.4T. Magn Reson Med 2024; 91:1268-1280. [PMID: 38009927 DOI: 10.1002/mrm.29941] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 10/29/2023] [Accepted: 11/08/2023] [Indexed: 11/29/2023]
Abstract
PURPOSE The aim of this work is to evaluate a new eight-channel transceiver (TxRx) coaxial dipole array for imaging of the human head at 9.4T developed to improve specific absorption rate (SAR) performance, and provide for a more compact and robust alternative to the state-of-the art dipole arrays. METHODS First, the geometry of a single coaxial element was optimized to minimize peak SAR and sensitivity to the load variation. Next, a multi-tissue voxel model was used to numerically simulate a TxRx array coil that consisted of eight coaxial dipoles with the optimal configuration. Finally, we compared the developed array to other human head dipole arrays. Results of numerical simulations were verified on a bench and in the scanner including in vivo measurements on a healthy volunteer. RESULTS The developed eight-element coaxial dipole TxRx array coil showed up to 1.1times higher SAR-efficiency than a similar in geometry folded-end and fractionated dipole array while maintaining whole brain coverage and low sensitivity of the resonance frequency to variation in the head size. CONCLUSION As a proof of concept, we developed and constructed a prototype of a 9.4T (400 MHz) human head array consisting of eight TxRx coaxial dipoles. The developed array improved SAR-efficiency and provided for a more compact and robust alternative to the folded-end dipole design. To the best of our knowledge, this is the first example of using coaxial dipoles for human head MRI at ultra-high field.
Collapse
Affiliation(s)
- G A Solomakha
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - D Bosch
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - F Glang
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - K Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - N I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| |
Collapse
|
3
|
Kazemivalipour E, Wald LL, Guerin B. Comparison of tight-fitting 7T parallel-transmit head array designs using excitation uniformity and local specific absorption rate metrics. Magn Reson Med 2024; 91:1209-1224. [PMID: 37927216 PMCID: PMC10848211 DOI: 10.1002/mrm.29900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 09/15/2023] [Accepted: 10/06/2023] [Indexed: 11/07/2023]
Abstract
PURPOSE We model the performance of parallel transmission (pTx) arrays with 8, 16, 24, and 32 channels and varying loop sizes built on a close-fitting helmet for brain imaging at 7 T and compare their local specific absorption rate (SAR) and flip-angle performances to that of birdcage coil (used as a baseline) and cylindrical 8-channel and 16-channel pTx coils (single-row and dual-row). METHODS We use the co-simulation approach along with MATLAB scripting for batch-mode simulation of the coils. For each coil, we extracted B1 + maps and SAR matrices, which we compressed using the virtual observation points algorithm, and designed slice-selective RF shimming pTx pulses with multiple local SAR and peak power constraints to generate L-curves in the transverse, coronal, and sagittal orientations. RESULTS Helmet designs outperformed cylindrical pTx arrays at a constant number of channels in the flip-angle uniformity at a constant local SAR metric: up to 29% for 8-channel arrays, and up to 34% for 16-channel arrays, depending on the slice orientation. For all helmet arrays, increasing the loop diameter led to better local SAR versus flip-angle uniformity tradeoffs, although this effect was more pronounced for the 8-channel and 16-channel systems than the 24-channel and 32-channel systems, as the former have more limited degrees of freedom and therefore benefit more from loop-size optimization. CONCLUSION Helmet pTx arrays significantly outperformed cylindrical arrays with the same number of channels in local SAR and flip-angle uniformity metrics. This improvement was especially pronounced for non-transverse slice excitations. Loop diameter optimization for helmets appears to favor large loops, compatible with nearest-neighbor decoupling by overlap.
Collapse
Affiliation(s)
- Ehsan Kazemivalipour
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Lawrence L. Wald
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Division of Health Sciences Technology, Cambridge, Massachusetts, USA
| | - Bastien Guerin
- A. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Nikulin AV, Bosch D, Solomakha GA, Glang F, Scheffler K, Avdievich NI. Double-row 16-element folded-end dipole transceiver array for 3D RF shimming of the whole human brain at 9.4 T. NMR IN BIOMEDICINE 2023; 36:e4981. [PMID: 37173759 DOI: 10.1002/nbm.4981] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 04/18/2023] [Accepted: 05/10/2023] [Indexed: 05/15/2023]
Abstract
Homogeneity and longitudinal coverage of transmit (Tx) human head RF coils at ultrahigh field (UHF, ≥7 T) can be improved by 3D RF shimming, which requires using multi-row Tx arrays. Examples of 3D RF shimming using double-row UHF loop transceiver (TxRx) and Tx arrays have been described previously. Dipole antennas provide unique simplicity and robustness while offering comparable Tx efficiency and signal-to-noise ratio to conventional loop designs. Single-row Tx and TxRx human head UHF dipole arrays have been previously described by multiple groups. Recently, we developed a novel type of dipole antenna, a folded-end dipole, and presented single-row eight-element array prototypes for human head imaging at 7 and 9.4 T. These studies have shown that the novel antenna design can improve the longitudinal coverage and minimize peak local specific absorption rate (SAR) as compared with common unfolded dipoles. In this work, we developed, constructed, and evaluated a 16-element double-row TxRx folded-end dipole array for human head imaging at 9.4 T. To minimize cross-talk between neighboring dipoles located in different rows, we used transformer decoupling, which decreased coupling to a level below -20 dB. The developed array design was demonstrated to be capable of 3D static RF shimming and can be potentially used for dynamic shimming using parallel transmission. For optimal phase shifts between the rows, the array provides 11% higher SAR efficiency and 18% higher homogeneity than a folded-end dipole single-row array of the same length. The design also offers a substantially simpler and more robust alternative to the common double-row loop array with about 10% higher SAR efficiency and better longitudinal coverage.
Collapse
Affiliation(s)
- Anton V Nikulin
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
- Center of Photonics and 2D Materials, Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | - Dario Bosch
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Georgiy A Solomakha
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Felix Glang
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| |
Collapse
|
5
|
D’Astous A, Cereza G, Papp D, Gilbert KM, Stockmann JP, Alonso-Ortiz E, Cohen-Adad J. Shimming toolbox: An open-source software toolbox for B0 and B1 shimming in MRI. Magn Reson Med 2023; 89:1401-1417. [PMID: 36441743 PMCID: PMC9910837 DOI: 10.1002/mrm.29528] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 10/21/2022] [Accepted: 10/25/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE Introduce Shimming Toolbox ( https://shimming-toolbox.org), an open-source software package for prototyping new methods and performing static, dynamic, and real-time B0 shimming as well as B1 shimming experiments. METHODS Shimming Toolbox features various field mapping techniques, manual and automatic masking for the brain and spinal cord, B0 and B1 shimming capabilities accessible through a user-friendly graphical user interface. Validation of Shimming Toolbox was demonstrated in three scenarios: (i) B0 dynamic shimming in the brain at 7T using custom AC/DC coils, (ii) B0 real-time shimming in the spinal cord at 3T, and (iii) B1 static shimming in the spinal cord at 7T. RESULTS The B0 dynamic shimming of the brain at 7T took about 10 min to perform. It showed a 47% reduction in the standard deviation of the B0 field, associated with noticeable improvements in geometric distortions in EPI images. Real-time dynamic xyz-shimming in the spinal cord took about 5 min and showed a 30% reduction in the standard deviation of the signal distribution. B1 static shimming experiments in the spinal cord took about 10 min to perform and showed a 40% reduction in the coefficient of variation of the B1 field. CONCLUSION Shimming Toolbox provides an open-source platform where researchers can collaborate, prototype and conveniently test B0 and B1 shimming experiments. Future versions will include additional field map preprocessing techniques, optimization algorithms, and compatibility across multiple MRI manufacturers.
Collapse
Affiliation(s)
- Alexandre D’Astous
- NeuroPoly Lab, Institute of Biomedical Engineering,
Polytechnique Montréal, Montréal, QC, Canada
| | - Gaspard Cereza
- NeuroPoly Lab, Institute of Biomedical Engineering,
Polytechnique Montréal, Montréal, QC, Canada
| | - Daniel Papp
- NeuroPoly Lab, Institute of Biomedical Engineering,
Polytechnique Montréal, Montréal, QC, Canada
| | - Kyle M. Gilbert
- Centre for Functional and Metabolic Mapping, The
University of Western Ontario, London, Ontario, Canada
| | - Jason P. Stockmann
- Athinoula A. Martinos Center for Biomedical Imaging,
Massachusetts General Hospital, Charlestown, MA, United States
- Harvard Medical School, Boston, MA, United States
| | - Eva Alonso-Ortiz
- NeuroPoly Lab, Institute of Biomedical Engineering,
Polytechnique Montréal, Montréal, QC, Canada
| | - Julien Cohen-Adad
- NeuroPoly Lab, Institute of Biomedical Engineering,
Polytechnique Montréal, Montréal, QC, Canada
- Functional Neuroimaging Unit, CRIUGM, Université de
Montréal, Montréal, QC, Canada
- Mila - Quebec AI Institute, Montréal, QC,
Canada
- Centre de recherche du CHU Sainte-Justine,
Université de Montréal, Montréal, QC, Canada
| |
Collapse
|
6
|
Williams SN, McElhinney P, Gunamony S. Ultra-high field MRI: parallel-transmit arrays and RF pulse design. Phys Med Biol 2023; 68. [PMID: 36410046 DOI: 10.1088/1361-6560/aca4b7] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 11/21/2022] [Indexed: 11/22/2022]
Abstract
This paper reviews the field of multiple or parallel radiofrequency (RF) transmission for magnetic resonance imaging (MRI). Currently the use of ultra-high field (UHF) MRI at 7 tesla and above is gaining popularity, yet faces challenges with non-uniformity of the RF field and higher RF power deposition. Since its introduction in the early 2000s, parallel transmission (pTx) has been recognized as a powerful tool for accelerating spatially selective RF pulses and combating the challenges associated with RF inhomogeneity at UHF. We provide a survey of the types of dedicated RF coils used commonly for pTx and the important modeling of the coil behavior by electromagnetic (EM) field simulations. We also discuss the additional safety considerations involved with pTx such as the specific absorption rate (SAR) and how to manage them. We then describe the application of pTx with RF pulse design, including a practical guide to popular methods. Finally, we conclude with a description of the current and future prospects for pTx, particularly its potential for routine clinical use.
Collapse
Affiliation(s)
- Sydney N Williams
- Imaging Centre of Excellence, University of Glasgow, Glasgow, United Kingdom
| | - Paul McElhinney
- Imaging Centre of Excellence, University of Glasgow, Glasgow, United Kingdom
| | - Shajan Gunamony
- Imaging Centre of Excellence, University of Glasgow, Glasgow, United Kingdom.,MR CoilTech Limited, Glasgow, United Kingdom
| |
Collapse
|
7
|
Avdievich NI, Nikulin AV, Ruhm L, Magill AW, Henning A, Scheffler K. Double-row dipole/loop combined array for human whole brain imaging at 7 T. NMR IN BIOMEDICINE 2022; 35:e4773. [PMID: 35580922 DOI: 10.1002/nbm.4773] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/29/2022] [Accepted: 05/14/2022] [Indexed: 06/15/2023]
Abstract
Important issues in designing radiofrequency (RF) coils for human head imaging at ultra-high field (UHF; ≥7 T) are the inhomogeneity and longitudinal coverage (along the magnet axis) of the transmit (Tx) RF field. Both the homogeneity and coverage produced by Tx volume coils can be improved by means of three-dimensional (3D) RF shimming, which requires the use of multirow Tx-arrays. In addition, according to recent findings of the ultimate intrinsic signal-to-noise ratio (UISNR) theory, the loop-only receive (Rx) arrays do not provide optimal SNR near the brain center at UHF. The latter can be obtained by combining complementary conductive structures carrying different current patterns (e.g., loops and dipole antennas). In this work, we developed, constructed, and evaluated a novel 32-element hybrid array design for human head imaging at 7 T. The array consists of 16 transceiver loops placed in two rows circumscribing the head and 16 folded-end Rx-only dipoles positioned in the centers of loops. By placing all elements in a single layer, we increased RF power deposition into the tissue and, thus, preserved the Tx-efficiency. Using this hybrid design also simplifies the coil structure by minimizing the total number of array elements. The array demonstrated whole brain coverage, 3D RF shimming capability, and high SNR. It provided ~15% higher SNR near the brain center and, depending on the RF shim mode, from 20% to 40% higher Tx-efficiency than a common commercial head array coil.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anton V Nikulin
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Arthur W Magill
- Department for Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Anke Henning
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| |
Collapse
|
8
|
Avdievich NI, Nikulin AV, Ruhm L, Magill AW, Glang F, Henning A, Scheffler K. A 32-element loop/dipole hybrid array for human head imaging at 7 T. Magn Reson Med 2022; 88:1912-1926. [PMID: 35766426 DOI: 10.1002/mrm.29347] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 05/16/2022] [Accepted: 05/16/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE To improve whole-brain SNR at 7 Tesla, a novel 32-element hybrid human head array coil was developed, constructed, and tested. METHODS Our general design strategy is based on 2 major ideas: Firstly, following suggestions of previous works based on the ultimate intrinsic SNR theory, we combined loops and dipoles for improvement of SNR near the head center. Secondly, we minimized the total number of array elements by using a hybrid combination of transceive (TxRx) and receive (Rx) elements. The new hybrid array consisted of 8 folded-end TxRx-dipole antennas and 3 rows of 24 Rx-loops all placed in a single layer on the surface of a tight-fit helmet. RESULTS The developed array significantly improved SNR in vivo both near the center (∼20%) and at the periphery (∼20% to 80%) in comparison to a common commercial array coil with 8 transmit (Tx) and 32 Rx-elements. Whereas 24 loops alone delivered central SNR very similar to that of the commercial coil, the addition of complementary dipole structures provided further improvement. The new array also provided ∼15% higher Tx efficiency and better longitudinal coverage than that of the commercial array. CONCLUSION The developed array coil demonstrated advantages in combining complementary TxRx and Rx resonant structures, that is, TxRx-dipoles and Rx-loops all placed in a single layer at the same distance to the head. This strategy improved both SNR and Tx-performance, as well as simplified the total head coil design, making it more robust.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anton V Nikulin
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Arthur W Magill
- Department for Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Felix Glang
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anke Henning
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| |
Collapse
|
9
|
A 16-Channel Dipole Antenna Array for Human Head Magnetic Resonance Imaging at 10.5 Tesla. SENSORS 2021; 21:s21217250. [PMID: 34770558 PMCID: PMC8587099 DOI: 10.3390/s21217250] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 10/28/2021] [Accepted: 10/29/2021] [Indexed: 01/26/2023]
Abstract
For ultra-high field and frequency (UHF) magnetic resonance imaging (MRI), the associated short wavelengths in biological tissues leads to penetration and homogeneity issues at 10.5 tesla (T) and require antenna transmit arrays for efficiently generated 447 MHz B1+ fields (defined as the transmit radiofrequency (RF) magnetic field generated by RF coils). Previously, we evaluated a 16-channel combined loop + dipole antenna (LD) 10.5 T head array. While the LD array configuration did not achieve the desired B1+ efficiency, it showed an improvement of the specific absorption rate (SAR) efficiency compared to the separate 8-channel loop and separate 8-channel dipole antenna arrays at 10.5 T. Here we compare a 16-channel dipole antenna array with a 16-channel LD array of the same dimensions to evaluate B1+ efficiency, 10 g SAR, and SAR efficiency. The 16-channel dipole antenna array achieved a 24% increase in B1+ efficiency in the electromagnetic simulation and MR experiment compared to the LD array, as measured in the central region of a phantom. Based on the simulation results with a human model, we estimate that a 16-channel dipole antenna array for human brain imaging can increase B1+ efficiency by 15% with similar SAR efficiency compared to a 16-channel LD head array.
Collapse
|
10
|
Avdievich NI, Solomakha G, Ruhm L, Henning A, Scheffler K. 9.4 T double-tuned 13 C/ 1 H human head array using a combination of surface loops and dipole antennas. NMR IN BIOMEDICINE 2021; 34:e4577. [PMID: 34169590 DOI: 10.1002/nbm.4577] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/17/2021] [Accepted: 06/02/2021] [Indexed: 06/13/2023]
Abstract
MRI at ultra-high field (UHF, ≥7 T) provides a natural strategy for improving the quality of X-nucleus magnetic resonance spectroscopy and imaging due to the intrinsic benefit of increased signal-to-noise ratio. Considering that RF coils require both local transmission and reception at UHF, the designs of double-tuned coils, which often consist of several layers of transmit and receive resonant elements, become quite complex. A few years ago, a new type of RF coil, ie a dipole antenna, was developed and used for human body and head imaging at UHF. Due to the mechanical and electrical simplicity of dipole antennas, combining an X-nucleus surface loop array with 1 H dipoles can substantially simplify the design of a double-tuned UHF human head array coil. Recently, we developed a novel bent folded-end dipole transceiver array for human head imaging at 9.4 T. The new eight-element dipole array demonstrated full brain coverage, and transmit efficiency comparable to that of the substantially more complex 16-element surface loop array. In this work, we developed, constructed and evaluated a double-tuned 13 C/1 H human head 9.4 T array consisting of eight 13 C transceiver surface loops and eight 1 H transceiver bent folded-end dipole antennas all placed in a single layer. We showed that interaction between loops and dipoles can be minimized by placing four 1 H traps into each 13 C loop. The presented double-tuned RF array coil substantially simplifies the design as compared with the common double-tuned surface loop arrays. At the same time, the coil demonstrated an improved 1 H longitudinal coverage and good transmit efficiency.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Georgiy Solomakha
- Department of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| |
Collapse
|
11
|
Evaluation of 8-Channel Radiative Antenna Arrays for Human Head Imaging at 10.5 Tesla. SENSORS 2021; 21:s21186000. [PMID: 34577210 PMCID: PMC8469352 DOI: 10.3390/s21186000] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 08/31/2021] [Accepted: 09/03/2021] [Indexed: 11/17/2022]
Abstract
For human head magnetic resonance imaging at 10.5 tesla (T), we built an 8-channel transceiver dipole antenna array and evaluated the influence of coaxial feed cables. The influence of coaxial feed cables was evaluated in simulation and compared against a physically constructed array in terms of transmit magnetic field (B1+) and specific absorption rate (SAR) efficiency. A substantial drop (23.1% in simulation and 20.7% in experiment) in B1+ efficiency was observed with a tight coaxial feed cable setup. For the investigation of the feed location, the center-fed dipole antenna array was compared to two 8-channel end-fed arrays: monopole and sleeve antenna arrays. The simulation results with a phantom indicate that these arrays achieved ~24% higher SAR efficiency compared to the dipole antenna array. For a human head model, we observed 30.8% lower SAR efficiency with the 8-channel monopole antenna array compared to the phantom. Importantly, our simulation with the human model indicates that the sleeve antenna arrays can achieve 23.8% and 21% higher SAR efficiency compared to the dipole and monopole antenna arrays, respectively. Finally, we obtained high-resolution human cadaver images at 10.5 T with the 8-channel sleeve antenna array.
Collapse
|
12
|
Avdievich NI, Solomakha G, Ruhm L, Nikulin AV, Magill AW, Scheffler K. Folded-end dipole transceiver array for human whole-brain imaging at 7 T. NMR IN BIOMEDICINE 2021; 34:e4541. [PMID: 33978270 DOI: 10.1002/nbm.4541] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 04/07/2021] [Accepted: 04/26/2021] [Indexed: 06/12/2023]
Abstract
The advancement of clinical applications of ultrahigh field (UHF) MRI depends heavily on advances in technology, including the development of new radiofrequency (RF) coil designs. Currently, the number of commercially available 7 T head RF coils is rather limited, implying a need to develop novel RF head coil designs that offer superior transmit and receive performance. RF coils to be used for clinical applications must be robust and reliable. In particular, for transmit arrays, if a transmit channel fails the local specific absorption rate may increase, significantly increasing local tissue heating. Recently, dipole antennas have been proposed and used to design UHF head transmit and receive arrays. The dipole provides a unique simplicity while offering comparable transmit efficiency and signal-to-noise ratio with the conventional loop design. Recently, we developed a novel array design in our laboratory using a folded-end dipole antenna. In this work, we developed, constructed and evaluated an eight-element transceiver bent folded-end dipole array for human head imaging at 7 T. Driven in the quadrature circularly polarized mode, the array demonstrated more than 20% higher transmit efficiency and significantly better whole-brain coverage than that provided by a widely used commercial array. In addition, we evaluated passive dipole antennas for decoupling the proposed array. We demonstrated that in contrast to the common unfolded dipole array, the passive dipoles moved away from the sample not only minimize coupling between the adjacent folded-end active dipoles but also produce practically no destructive interference with the quadrature mode of the array.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Georgiy Solomakha
- Department of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anton V Nikulin
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Arthur W Magill
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| |
Collapse
|
13
|
Woo MK, Delabarre L, Waks M, Lee J, Lagore RL, Jungst S, Grant A, Eryaman Y, Ugurbil K, Adriany G. Comparison of 16-Channel Asymmetric Sleeve Antenna and Dipole Antenna Transceiver Arrays at 10.5 Tesla MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:1147-1156. [PMID: 33360987 PMCID: PMC8078892 DOI: 10.1109/tmi.2020.3047354] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Multi-element transmit arrays with low peak 10 g specific absorption rate (SAR) and high SAR efficiency (defined as ( [Formula: see text]SAR [Formula: see text] are essential for ultra-high field (UHF) magnetic resonance imaging (MRI) applications. Recently, the adaptation of dipole antennas used as MRI coil elements in multi-channel arrays has provided the community with a technological solution capable of producing uniform images and low SAR efficiency at these high field strengths. However, human head-sized arrays consisting of dipole elements have a practical limitation to the number of channels that can be used due to radiofrequency (RF) coupling between the antenna elements, as well as, the coaxial cables necessary to connect them. Here we suggest an asymmetric sleeve antenna as an alternative to the dipole antenna. When used in an array as MRI coil elements, the asymmetric sleeve antenna can generate reduced peak 10 g SAR and improved SAR efficiency. To demonstrate the advantages of an array consisting of our suggested design, we compared various performance metrics produced by 16-channel arrays of asymmetric sleeve antennas and dipole antennas with the same dimensions. Comparison data were produced on a phantom in electromagnetic (EM) simulations and verified with experiments at 10.5 Tesla (T). The results produced by the 16-channel asymmetric sleeve antenna array demonstrated 28 % lower peak 10 g SAR and 18.6 % higher SAR efficiency when compared to the 16-channel dipole antenna array.
Collapse
|
14
|
Avdievich NI, Solomakha G, Ruhm L, Henning A, Scheffler K. Unshielded bent folded-end dipole 9.4 T human head transceiver array decoupled using modified passive dipoles. Magn Reson Med 2021; 86:581-597. [PMID: 33629436 DOI: 10.1002/mrm.28711] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 01/14/2021] [Accepted: 01/14/2021] [Indexed: 11/10/2022]
Abstract
PURPOSE To develop an unshielded dipole transceiver array for human head imaging at 9.4 Tesla and to improve decoupling of adjacent dipole elements, a novel array design with modified passive dipole antennas was developed, evaluated, and tested. METHODS The new array consisted of 8 bent folded-end dipole elements placed in a single row and surrounding the head. Adjacent elements of RF transceiver arrays are usually decoupled by introducing circuits electrically connected to elements. These methods are difficult to use for dipole arrays because of the distant location of the adjacent antennas. A recently developed decoupling technique using passive dipoles is simple and does not require any electrical connection. However, common parallel passive dipoles can produce destructive interference with the RF field of the array itself. To minimize this interference, we placed the passive dipoles perpendicularly to the active dipoles and positioned them at the ends of the array. We also evaluated the effect of different passive dipoles on the array transmit performance. Finally, we optimized the array transmit performance by varying the length of the dipole folded portion. RESULTS By rotating the passive dipoles 90º and moving them toward the ends of the array, we minimized the destructive interference to an acceptable level without compromising decoupling and the transmit efficiency. CONCLUSION While keeping the benefits of the passive dipole decoupling method, the new modified dipoles produce substantially less destructive interference with the RF field of the array than the common design. The constructed transceiver array demonstrated good decoupling and whole-brain coverage.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Georgiy Solomakha
- Department of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| |
Collapse
|
15
|
Woo MK, DelaBarre L, Lee BY, Waks M, Lagore RL, Radder J, Eryaman Y, Ugurbil K, Adriany G. Evaluation of a 16-channel transceiver loop + dipole antenna array for human head imaging at 10.5 tesla. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2020; 8:203555-203563. [PMID: 33747679 PMCID: PMC7978235 DOI: 10.1109/access.2020.3036598] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We evaluated a 16-channel loop + dipole (LD) transceiver antenna array with improved specific absorption rate (SAR) efficiency for 10.5 Tesla (T) human head imaging apsplications. Three different array designs with equal inner dimensions were considered: an 8-channel dipole antenna, an 8-channel loop, and a 16-channel LD antenna arrays. Signal-to-noise ratio (SNR) and B1 + efficiency (in units of μT per √W) were simulated and measured in 10.5 T magnetic resonance imaging (MRI) experiments. For the safety validation, 10 g SAR and SAR efficiency (defined as the B1 + over √ (peak 10 g SAR)) were calculated through simulation. Finally, high resolution porcine brain images were acquired with the 16-channel LD antenna array, including a fast turbo-spin echo (TSE) sequence incorporating B1 shimming techniques. Both the simulation and experiments demonstrated that the combined 16-channel LD antenna array showed similar B1 + efficiency compared to the 8-channel dipole antenna and the 8-channel loop arrays in a circular polarized (CP) mode. In a central 2 mm × 2 mm region of the phantom, however, the 16-channel LD antenna array showed an improvement in peak 10 g SAR of 27.5 % and 32.5 % over the 8-channel dipole antenna and the 8-channel loop arrays, respectively. We conclude that the proposed 16-channel head LD antenna array design is capable of achieving ~7% higher SAR efficiency at 10.5 T compared to either the 8-channel loop-only or the 8-channel dipole-only antenna arrays of the same dimensions.
Collapse
Affiliation(s)
- Myung Kyun Woo
- Center for Magnetic Resonance and Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Lance DelaBarre
- Center for Magnetic Resonance and Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Byeong-Yeul Lee
- National Institute of Allergy and Infectious Diseases (NIAID), Integrated Research Facility (IRF), Frederick, Maryland, USA
| | - Matt Waks
- Center for Magnetic Resonance and Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Russell Luke Lagore
- Center for Magnetic Resonance and Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Jerahmie Radder
- Center for Magnetic Resonance and Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Yigitcan Eryaman
- Center for Magnetic Resonance and Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Kamil Ugurbil
- Center for Magnetic Resonance and Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Gregor Adriany
- Center for Magnetic Resonance and Research, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
16
|
Kazemivalipour E, Sadeghi-Tarakameh A, Atalar E. Eigenmode analysis of the scattering matrix for the design of MRI transmit array coils. Magn Reson Med 2020; 85:1727-1741. [PMID: 33034125 DOI: 10.1002/mrm.28533] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 09/03/2020] [Accepted: 09/04/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE To obtain efficient operation modes of transmit array (TxArray) coils using a general design technique based on the eigenmode analysis of the scattering matrix. METHODS We introduce the concept of modal reflected power and excitation eigenmodes, which are calculated as the eigenvalues and eigenvectors of SH S, where the superscript H denotes the Hermitian transpose. We formulate the normalized reflected power, which is the ratio of the total reflected power to the total incident power of TxArray coils for a given excitation signal as the weighted sum of the modal reflected power. By minimizing the modal reflected power of TxArray coils, we increase the excitation space with a low total reflection. The algorithm was tested on 4 dual-row TxArray coils with 8 to 32 channels. RESULTS By minimizing the modal reflected power, we designed an 8-element TxArray coil to have a low reflection for 7 out of 8 dimensions of the excitation space. Similarly, the minimization of the modal reflected power of a 16-element TxArray coil enabled us to enlarge the dimension of the excitation space by 50% compared with commonly employed design techniques. Moreover, we demonstrated that the low total reflected power for some critical excitation modes, such as the circularly polarized mode, can be achieved for all TxArray coils even with a high level of coupling. CONCLUSION Eigenmode analysis is an efficient method that intuitively provides a quantitative and compact representation of the coil's power transmission capabilities. This method also provides insight into the excitation modes with low reflection.
Collapse
Affiliation(s)
- Ehsan Kazemivalipour
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Alireza Sadeghi-Tarakameh
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Ergin Atalar
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| |
Collapse
|
17
|
Avdievich NI, Solomakha G, Ruhm L, Scheffler K, Henning A. Decoupling of folded-end dipole antenna elements of a 9.4 T human head array using an RF shield. NMR IN BIOMEDICINE 2020; 33:e4351. [PMID: 32618047 DOI: 10.1002/nbm.4351] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 05/22/2020] [Accepted: 05/22/2020] [Indexed: 06/11/2023]
Abstract
Dipole antennas have recently been introduced to the field of MRI and successfully used, mostly as elements of ultra-high field (UHF, ≥ 7 T) human body arrays. Usage of dipole antennas for UHF human head transmit (Tx) arrays is still under development. Due to the substantially smaller size of the sample, dipoles must be made significantly shorter than in the body array. Additionally, head Tx arrays are commonly placed on the surface of rigid helmets made sufficiently large to accommodate tight-fit receive arrays. As a result, dipoles are not well loaded and are often poorly decoupled, which compromises Tx efficiency. Commonly, adjacent array elements are decoupled by circuits electrically connected to them. Placement of such circuits between distantly located dipoles is difficult. Alternatively, decoupling is provided by placing passive antennas between adjacent dipole elements. This method only works when these additional components are sufficiently small (compared with the size of active dipoles). Otherwise, RF fields produced by passive elements interfere destructively with the RF field of the array itself, and previously reported designs have used passive dipoles of about the size of array dipoles. In this work, we developed a novel method of decoupling for adjacent dipole antennas, and used this technique while constructing a 9.4 T human head eight-element transceiver array. Decoupling is provided without any additional circuits by simply folding the dipoles and using an RF shield located close to the folded portion of the dipoles. The array reported in this work demonstrates good decoupling and whole-brain coverage.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Georgiy Solomakha
- Department of Physics and Engineering, ITMO University, Saint Petersburg, Russia
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, USA
| |
Collapse
|
18
|
Avdievich NI, Solomakha G, Ruhm L, Bause J, Scheffler K, Henning A. Bent folded‐end dipole head array for ultrahigh‐field MRI turns “dielectric resonance” from an enemy to a friend. Magn Reson Med 2020; 84:3453-3467. [DOI: 10.1002/mrm.28336] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 04/16/2020] [Accepted: 05/03/2020] [Indexed: 11/05/2022]
Affiliation(s)
- Nikolai I. Avdievich
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Georgiy Solomakha
- Department of Physics and Engineering ITMO University St. Petersburg Russia
| | - Loreen Ruhm
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Jonas Bause
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
- Graduate School of Neural and Behavioral Sciences Tübingen Germany
| | - Klaus Scheffler
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
- Department for Biomedical Magnetic Resonance University of Tübingen Tübingen Germany
| | - Anke Henning
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
- Advanced Imaging Research Center University of Texas Southwestern Medical Center Dallas TX USA
| |
Collapse
|
19
|
Avdievich NI, Ruhm L, Dorst J, Scheffler K, Korzowski A, Henning A. Double‐tuned
31
P/
1
H human head array with high performance at both frequencies for spectroscopic imaging at 9.4T. Magn Reson Med 2020; 84:1076-1089. [DOI: 10.1002/mrm.28176] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 12/30/2019] [Accepted: 12/30/2019] [Indexed: 11/09/2022]
Affiliation(s)
- Nikolai I. Avdievich
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Loreen Ruhm
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Johanna Dorst
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Klaus Scheffler
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
- Department for Biomedical Magnetic Resonance University of Tübingen Tübingen Germany
| | - Andreas Korzowski
- Department for Medical Physics in Radiology German Cancer Research Center (DKFZ) Heidelberg Germany
| | - Anke Henning
- High‐Field MR Center Max Planck Institute for Biological Cybernetics Tübingen Germany
- Advanced Imaging Research Center University of Texas Southwestern Medical Center Dallas Texas
| |
Collapse
|
20
|
Avdievich NI, Solomakha G, Ruhm L, Scheffler K, Henning A. Evaluation of short folded dipole antennas as receive elements of ultra‐high‐field human head array. Magn Reson Med 2019; 82:811-824. [DOI: 10.1002/mrm.27754] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Revised: 03/04/2019] [Accepted: 03/07/2019] [Indexed: 11/11/2022]
Affiliation(s)
- Nikolai I. Avdievich
- High‐Field MR Center, Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Georgiy Solomakha
- Department of Nanophotonics and Metamaterials ITMO University St. Petersburg Russia
| | - Loreen Ruhm
- High‐Field MR Center, Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Klaus Scheffler
- High‐Field MR Center, Max Planck Institute for Biological Cybernetics Tübingen Germany
- Department for Biomedical Magnetic Resonance University of Tübingen Tübingen Germany
| | - Anke Henning
- High‐Field MR Center, Max Planck Institute for Biological Cybernetics Tübingen Germany
- Advanced Imaging Research Center University of Texas Southwestern Medical Center Dallas Texas
| |
Collapse
|
21
|
Solomakha G, Andreychenko A, Moortele PFVD, Kroeze H, Raaijmakers AJ, Euwe FE, Lagendijk JJW, Luijten PR, Berg CATVD. A Coaxial RF Applicator for Ultra-High Field Human MRI. IEEE Trans Biomed Eng 2019; 66:2848-2854. [PMID: 30716028 DOI: 10.1109/tbme.2019.2897029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE To develop a novel radio-frequency (RF) concept for ultra-high field (UHF) human magnetic resonance imaging (MRI) based on a coaxial resonant cavity. METHODS A two-channel slotted coaxial cavity RF applicator was designed for human head MRI at 9.4T. Physical dimensions made the proposed conducting structure resonant at the required frequency without tuning lumped elements. Numerical electromagnetic modeling was used to optimize the design. RF safety was assessed with two representative human body models. MR experiments on a 9.4T scanner included gradient echo images and mapping of a circularly polarized RF magnetic field in the human head phantom. RESULTS The simulations and the phantom MR experiments agreed both qualitatively and quantitatively. The design was relatively simple, robust and required only a few additional reactive elements for the applicator's input impedance matching. The transmit efficiency and homogeneity of the excitation field were only 20% and 4% lower compared to a conventional 8-channel head array. CONCLUSION The coaxial RF applicator was feasible for human MRI at UHF and required no lumped elements for its tuning. Imaging performance of the RF applicator was only moderately lower compared to the conventional transmit array, but would be sufficient to provide an anatomical reference for the heteronuclei MRI. SIGNIFICANCE An alternative approach with the minimal involvement of lumped elements becomes feasible to design volume-type RF coils for UHF human MRI.
Collapse
|
22
|
Krishnamurthy N, Santini T, Wood S, Kim J, Zhao T, Aizenstein HJ, Ibrahim TS. Computational and experimental evaluation of the Tic-Tac-Toe RF coil for 7 Tesla MRI. PLoS One 2019; 14:e0209663. [PMID: 30629618 PMCID: PMC6328242 DOI: 10.1371/journal.pone.0209663] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 12/10/2018] [Indexed: 01/18/2023] Open
Abstract
A variety of 7 Tesla RF coil systems have been proposed to produce spin excitation (B1+ field) and MR image acquisition. Different groups have attempted to mitigate the challenges at high and ultra-high field MRI by proposing novel hardware and software solutions to obtain uniformly high spin excitation at acceptable RF absorption levels. In this study, we extensively compare the designs of two distributed-circuit based RF coils: the Tic-Tac-Toe (TTT) head coil and TEM head coil on multiple anatomically detailed head models and in-vivo. Bench measurements of s-parameters and experimental B1+ field distribution were obtained in volunteers and compared with numerical simulations. RF absorption, quantified by both average and peak SAR, and B1+ field intensity and homogeneity, calculated/measured in terms of maximum over minimum and coefficient of variation (CV) in the region of interest (ROI), are presented for both coils. A study of the RF consistency of both coils across multiple head models for different RF excitation strategies is also presented.
Collapse
Affiliation(s)
- Narayanan Krishnamurthy
- University of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America
| | - Tales Santini
- University of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America
| | - Sossena Wood
- University of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America
| | - Junghwan Kim
- University of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America
| | - Tiejun Zhao
- Siemens Medical Solutions, New York, NY, United States of America
| | - Howard J. Aizenstein
- University of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America
- University of Pittsburgh, Department of Psychiatry, Pittsburgh, PA, United States of America
| | - Tamer S. Ibrahim
- University of Pittsburgh, Department of Bioengineering, Pittsburgh, PA, United States of America
- University of Pittsburgh, Department of Psychiatry, Pittsburgh, PA, United States of America
- University of Pittsburgh, Department of Radiology, Pittsburgh, PA, United States of America
| |
Collapse
|
23
|
Avdievich NI, Giapitzakis IA, Bause J, Shajan G, Scheffler K, Henning A. Double-row 18-loop transceive-32-loop receive tight-fit array provides for whole-brain coverage, high transmit performance, and SNR improvement near the brain center at 9.4T. Magn Reson Med 2018; 81:3392-3405. [PMID: 30506725 DOI: 10.1002/mrm.27602] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 09/12/2018] [Accepted: 10/19/2018] [Indexed: 11/06/2022]
Abstract
PURPOSE To improve the transmit (Tx) and receive (Rx) performance of a human head array and provide whole-brain coverage at 9.4T, a novel 32-element array design was developed, constructed, and tested. METHODS The array consists of 18 transceiver (TxRx) surface loops and 14 Rx-only vertical loops all placed in a single layer. The new design combines benefits of both TxRx and transmit-only-receive-only (ToRo) designs. The general idea of the design is that the total number of array elements (both TxRx and Rx) should not exceed the number of required Rx elements. First, the necessary number of TxRx loops is placed around the object tightly to optimize the Tx performance. The rest of the elements are loops, which are used only for reception. We also compared the performance of the new array with that of a state-of-the-art ToRo array consisting of 16 Tx-only loops and 31 Rx-only loops. RESULTS The new array provides whole-brain coverage, ~1.5 times greater Tx efficiency and 1.3 times higher SNR near the brain center as compared to the ToRo array, while the latter delivers higher (up to 1.5 times) peripheral SNR. CONCLUSION In general, the new approach of constructing a single-layer array consisting of both TxRx- and Rx-only elements simplifies the array construction by minimizing the total number of elements and makes the entire design more robust and, therefore, safe. Overall, our work provides a recipe for a Tx- and Rx-efficient head array coil suitable for parallel transmission and reception as well as whole-brain imaging at UHF.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Ioannis-Angelos Giapitzakis
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Graduate School of Neural and Behavioral Sciences, Tübingen, Germany
| | - Jonas Bause
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Graduate School of Neural and Behavioral Sciences, Tübingen, Germany
| | - Gunamony Shajan
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Institute of Neuroscience and Psychology, University of Glasgow, Glasgow, United Kingdom
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| |
Collapse
|
24
|
Ladd ME, Bachert P, Meyerspeer M, Moser E, Nagel AM, Norris DG, Schmitter S, Speck O, Straub S, Zaiss M. Pros and cons of ultra-high-field MRI/MRS for human application. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2018; 109:1-50. [PMID: 30527132 DOI: 10.1016/j.pnmrs.2018.06.001] [Citation(s) in RCA: 264] [Impact Index Per Article: 44.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 06/06/2018] [Accepted: 06/07/2018] [Indexed: 05/08/2023]
Abstract
Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.
Collapse
Affiliation(s)
- Mark E Ladd
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Medicine, University of Heidelberg, Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany; Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Peter Bachert
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany.
| | - Martin Meyerspeer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Center of Excellence, Medical University of Vienna, Vienna, Austria.
| | - Ewald Moser
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Center of Excellence, Medical University of Vienna, Vienna, Austria.
| | - Armin M Nagel
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | - David G Norris
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen, Nijmegen, Netherlands; Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Sebastian Schmitter
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany; German Center for Neurodegenerative Diseases, Magdeburg, Germany; Center for Behavioural Brain Sciences, Magdeburg, Germany; Leibniz Institute for Neurobiology, Magdeburg, Germany.
| | - Sina Straub
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
| | - Moritz Zaiss
- High-Field Magnetic Resonance Center, Max-Planck-Institute for Biological Cybernetics, Tübingen, Germany.
| |
Collapse
|
25
|
Giapitzakis I, Borbath T, Murali‐Manohar S, Avdievich N, Henning A. Investigation of the influence of macromolecules and spline baseline in the fitting model of human brain spectra at 9.4T. Magn Reson Med 2018; 81:746-758. [DOI: 10.1002/mrm.27467] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Revised: 06/10/2018] [Accepted: 07/05/2018] [Indexed: 11/10/2022]
Affiliation(s)
- Ioannis‐Angelos Giapitzakis
- High‐Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics Tübingen Germany
- IMPRS for Cognitive and Systems Neuroscience Tübingen Germany
| | - Tamas Borbath
- High‐Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics Tübingen Germany
- Faculty of Science University of Tübingen Tübingen Germany
| | - Saipavitra Murali‐Manohar
- High‐Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics Tübingen Germany
- Faculty of Science University of Tübingen Tübingen Germany
| | - Nikolai Avdievich
- High‐Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics Tübingen Germany
- Institute of Physics University of Greifswald Greifswald Germany
| | - Anke Henning
- High‐Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics Tübingen Germany
- Institute of Physics University of Greifswald Greifswald Germany
| |
Collapse
|
26
|
Avdievich NI, Giapitzakis IA, Pfrommer A, Shajan G, Scheffler K, Henning A. Decoupling of a double-row 16-element tight-fit transceiver phased array for human whole-brain imaging at 9.4 T. NMR IN BIOMEDICINE 2018; 31:e3964. [PMID: 29974989 DOI: 10.1002/nbm.3964] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Revised: 05/04/2018] [Accepted: 05/27/2018] [Indexed: 06/08/2023]
Abstract
One of the major challenges in constructing multi-channel and multi-row transmit (Tx) or transceiver (TxRx) arrays is the decoupling of the array's loop elements. Overlapping of the surface loops allows the decoupling of adjacent elements and also helps to improve the radiofrequency field profile by increasing the penetration depth and eliminating voids between the loops. This also simplifies the design by reducing the number of decoupling circuits. At the same time, overlapping may compromise decoupling by generating high resistive (electric) coupling near the overlap, which cannot be compensated for by common decoupling techniques. Previously, based on analytical modeling, we demonstrated that electric coupling has strong frequency and loading dependence, and, at 9.4 T, both the magnetic and electric coupling between two heavily loaded loops can be compensated at the same time simply by overlapping the loops. As a result, excellent decoupling was obtained between adjacent loops of an eight-loop single-row (1 × 8) human head tight-fit TxRx array. In this work, we designed and constructed a 9.4-T (400-MHz) 16-loop double-row (2 × 8) overlapped TxRx head array based on the results of the analytical and numerical electromagnetic modeling. We demonstrated that, simply by the optimal overlap of array loops, a very good decoupling can be obtained without additional decoupling strategies. The constructed TxRx array provides whole-brain coverage and approximately 1.5 times greater Tx efficiency relative to a transmit-only/receive-only (ToRo) array, which consists of a larger Tx-only array and a nested tight-fit 31-loop receive (Rx)-only array. At the same time, the ToRo array provides greater peripheral signal-to-noise ratio (SNR) and better Rx parallel performance in the head-feet direction. Overall, our work provides a recipe for a simple, robust and very Tx-efficient design suitable for parallel transmission and whole-brain imaging at ultra-high fields.
Collapse
Affiliation(s)
- Nikolai I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany
- Institute of Physics, Ernst-Moritz-Arndt University, Greifswald, Germany
| | - Ioannis A Giapitzakis
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany
- Graduate School of Neural and Behavioral Sciences, Tübingen, Germany
| | - Andreas Pfrommer
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany
| | - Gunamony Shajan
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany
| | - Klaus Scheffler
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany
- Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany
- Institute of Physics, Ernst-Moritz-Arndt University, Greifswald, Germany
| |
Collapse
|
27
|
Avdievich NI, Giapitzakis IA, Pfrommer A, Borbath T, Henning A. Combination of surface and 'vertical' loop elements improves receive performance of a human head transceiver array at 9.4 T. NMR IN BIOMEDICINE 2018; 31:e3878. [PMID: 29244225 DOI: 10.1002/nbm.3878] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Revised: 10/26/2017] [Accepted: 11/13/2017] [Indexed: 06/07/2023]
Abstract
Ultra-high-field (UHF, ≥7 T) human magnetic resonance imaging (MRI) provides undisputed advantages over low-field MRI (≤3 T), but its development remains challenging because of numerous technical issues, including the low efficiency of transmit (Tx) radiofrequency (RF) coils caused by the increase in tissue power deposition with frequency. Tight-fit human head transceiver (TxRx) arrays improve Tx efficiency in comparison with Tx-only arrays, which are larger in order to fit multi-channel receive (Rx)-only arrays inside. A drawback of the TxRx design is that the number of elements in an array is limited by the number of available high-power RF Tx channels (commonly 8 or 16), which is not sufficient for optimal Rx performance. In this work, as a proof of concept, we developed a method for increasing the number of Rx elements in a human head TxRx surface loop array without the need to move the loops away from a sample, which compromises the array Tx performance. We designed and constructed a prototype 16-channel tight-fit array, which consists of eight TxRx surface loops placed on a cylindrical holder circumscribing a head, and eight Rx-only vertical loops positioned along the central axis (parallel to the magnetic field B0 ) of each TxRx loop, perpendicular to its surface. We demonstrated both experimentally and numerically that the addition of the vertical loops has no measurable effect on the Tx efficiency of the array. An increase in the maximum local specific absorption rate (SAR), evaluated using two human head voxel models (Duke and Ella), measured 3.4% or less. At the same time, the 16-element array provided 30% improvement of central signal-to-noise ratio (SNR) in vivo relative to a surface loop eight-element array. The novel array design also demonstrated an improvement in the parallel Rx performance in the transversal plane. Thus, using this method, both the Rx and Tx performance of the human head array can be optimized simultaneously.
Collapse
Affiliation(s)
- N I Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Institute of Physics, Ernst-Moritz-Arndt University Greifswald, Greifswald, Germany
| | - I A Giapitzakis
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Graduate School of Neural and Behavioral Sciences, Tübingen, Germany
| | - A Pfrommer
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - T Borbath
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - A Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Institute of Physics, Ernst-Moritz-Arndt University Greifswald, Greifswald, Germany
| |
Collapse
|
28
|
Giapitzakis IA, Avdievich N, Henning A. Characterization of macromolecular baseline of human brain using metabolite cycled semi-LASER at 9.4T. Magn Reson Med 2018; 80:462-473. [DOI: 10.1002/mrm.27070] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 12/12/2017] [Accepted: 12/12/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Ioannis-Angelos Giapitzakis
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics; Tübingen Germany
- IMPRS for Cognitive & Systems Neuroscience; Tübingen Germany
| | - Nikolai Avdievich
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics; Tübingen Germany
- Institute of Physics; University of Greifswald; Greifswald Germany
| | - Anke Henning
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics; Tübingen Germany
- Institute of Physics; University of Greifswald; Greifswald Germany
| |
Collapse
|
29
|
Avdievich NI, Giapitzakis IA, Pfrommer A, Henning A. Decoupling of a tight-fit transceiver phased array for human brain imaging at 9.4T: Loop overlapping rediscovered. Magn Reson Med 2017; 79:1200-1211. [DOI: 10.1002/mrm.26754] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2016] [Revised: 04/20/2017] [Accepted: 04/20/2017] [Indexed: 11/05/2022]
Affiliation(s)
- Nikolai I. Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics; Tübingen Germany
- Institute of Physics, Ernst-Moritz-Arndt University Greifswald; Greifswald Germany
| | | | - Andreas Pfrommer
- High-Field MR Center, Max Planck Institute for Biological Cybernetics; Tübingen Germany
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics; Tübingen Germany
- Institute of Physics, Ernst-Moritz-Arndt University Greifswald; Greifswald Germany
| |
Collapse
|
30
|
Nassirpour S, Chang P, Fillmer A, Henning A. A comparison of optimization algorithms for localized in vivo B 0 shimming. Magn Reson Med 2017; 79:1145-1156. [PMID: 28543722 DOI: 10.1002/mrm.26758] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Revised: 04/05/2017] [Accepted: 04/29/2017] [Indexed: 01/06/2023]
Abstract
PURPOSE To compare several different optimization algorithms currently used for localized in vivo B0 shimming, and to introduce a novel, fast, and robust constrained regularized algorithm (ConsTru) for this purpose. METHODS Ten different optimization algorithms (including samples from both generic and dedicated least-squares solvers, and a novel constrained regularized inversion method) were implemented and compared for shimming in five different shimming volumes on 66 in vivo data sets from both 7 T and 9.4 T. The best algorithm was chosen to perform single-voxel spectroscopy at 9.4 T in the frontal cortex of the brain on 10 volunteers. RESULTS The results of the performance tests proved that the shimming algorithm is prone to unstable solutions if it depends on the value of a starting point, and is not regularized to handle ill-conditioned problems. The ConsTru algorithm proved to be the most robust, fast, and efficient algorithm among all of the chosen algorithms. It enabled acquisition of spectra of reproducible high quality in the frontal cortex at 9.4 T. CONCLUSIONS For localized in vivo B0 shimming, the use of a dedicated linear least-squares solver instead of a generic nonlinear one is highly recommended. Among all of the linear solvers, the constrained regularized method (ConsTru) was found to be both fast and most robust. Magn Reson Med 79:1145-1156, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Sahar Nassirpour
- Max Planck Institute for Biological Cybernetics, Tuebingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, Eberhard-Karls University of Tuebingen, Germany
| | - Paul Chang
- Max Planck Institute for Biological Cybernetics, Tuebingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, Eberhard-Karls University of Tuebingen, Germany
| | | | - Anke Henning
- Max Planck Institute for Biological Cybernetics, Tuebingen, Germany.,Institute for Biomedical Engineering, UZH and ETH Zürich, Zürich, Switzerland
| |
Collapse
|