1
|
Sen S, Singh S, Pye H, Moore CM, Whitaker HC, Punwani S, Atkinson D, Panagiotaki E, Slator PJ. ssVERDICT: Self-supervised VERDICT-MRI for enhanced prostate tumor characterization. Magn Reson Med 2024; 92:2181-2192. [PMID: 38852195 DOI: 10.1002/mrm.30186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 05/17/2024] [Accepted: 05/17/2024] [Indexed: 06/11/2024]
Abstract
PURPOSE Demonstrating and assessing self-supervised machine-learning fitting of the VERDICT (vascular, extracellular and restricted diffusion for cytometry in tumors) model for prostate cancer. METHODS We derive a self-supervised neural network for fitting VERDICT (ssVERDICT) that estimates parameter maps without training data. We compare the performance of ssVERDICT to two established baseline methods for fitting diffusion MRI models: conventional nonlinear least squares and supervised deep learning. We do this quantitatively on simulated data by comparing the Pearson's correlation coefficient, mean-squared error, bias, and variance with respect to the simulated ground truth. We also calculate in vivo parameter maps on a cohort of 20 prostate cancer patients and compare the methods' performance in discriminating benign from cancerous tissue via Wilcoxon's signed-rank test. RESULTS In simulations, ssVERDICT outperforms the baseline methods (nonlinear least squares and supervised deep learning) in estimating all the parameters from the VERDICT prostate model in terms of Pearson's correlation coefficient, bias, and mean-squared error. In vivo, ssVERDICT shows stronger lesion conspicuity across all parameter maps, and improves discrimination between benign and cancerous tissue over the baseline methods. CONCLUSION ssVERDICT significantly outperforms state-of-the-art methods for VERDICT model fitting and shows, for the first time, fitting of a detailed multicompartment biophysical diffusion MRI model with machine learning without the requirement of explicit training labels.
Collapse
Affiliation(s)
- Snigdha Sen
- Center for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Saurabh Singh
- Center for Medical Imaging, Division of Medicine, University College London, London, UK
| | - Hayley Pye
- Department of Targeted Intervention, Division of Surgery and Interventional Science, University College London, London, UK
| | - Caroline M Moore
- Department of Targeted Intervention, Division of Surgery and Interventional Science, University College London, London, UK
| | - Hayley C Whitaker
- Department of Targeted Intervention, Division of Surgery and Interventional Science, University College London, London, UK
| | - Shonit Punwani
- Center for Medical Imaging, Division of Medicine, University College London, London, UK
| | - David Atkinson
- Center for Medical Imaging, Division of Medicine, University College London, London, UK
| | - Eleftheria Panagiotaki
- Center for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Paddy J Slator
- Center for Medical Image Computing, Department of Computer Science, University College London, London, UK
- Cardiff University Brain Research Imaging Center, School of Psychology, Cardiff University, Cardiff, UK
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK
| |
Collapse
|
2
|
Huang HM. Calculation of intravoxel incoherent motion parameter maps using a kernelized total difference-based method. NMR IN BIOMEDICINE 2024; 37:e5201. [PMID: 38863271 DOI: 10.1002/nbm.5201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 05/13/2024] [Accepted: 05/23/2024] [Indexed: 06/13/2024]
Abstract
Quantitative analysis of diffusion-weighted magnetic resonance imaging (DW-MRI) has been explored for many clinical applications since its development. In particular, the intravoxel incoherent motion (IVIM) model for DW-MRI has been commonly utilized in various organs. However, because of the presence of excessive noise, the IVIM parameter maps obtained from pixel-wise fitting are often unreliable. In this study, we propose a kernelized total difference-based curve-fitting method to estimate the IVIM parameters. Simulated DW-MRI data at five signal-to-noise ratios (i.e., 10, 20, 30, 50, and 100) and real abdominal DW-MRI data acquired on a 1.5-T MRI scanner with nine b-values (i.e., 0, 10, 25, 50, 100, 200, 300, 400, and 500 s/mm2) and six diffusion-encoding gradient directions were used to evaluate the performance of the proposed method. The results were compared with those obtained by three existing methods: trust-region reflective (TRR) algorithm, Bayesian probability (BP), and deep neural network (DNN). Our simulation results showed that the proposed method outperformed the other three comparing methods in terms of root-mean-square error. Moreover, the proposed method could preserve small details in the estimated IVIM parameter maps. The experimental results showed that, compared with the TRR method, the proposed method as well as the BP (and DNN) method could reduce the overestimation of the pseudodiffusion coefficient and improve the quality of IVIM parameter maps. For all studied abdominal organs except the pancreas, both the proposed method and the BP method could provide IVIM parameter estimates close to the reference values; the former had higher precision. The kernelized total difference-based curve-fitting method has the potential to improve the reliability of IVIM parametric imaging.
Collapse
Affiliation(s)
- Hsuan-Ming Huang
- Institute of Medical Device and Imaging, College of Medicine, National Taiwan University, Taipei City, Taiwan
- Program for Precision Health and Intelligent Medicine, Graduate School of Advanced Technology, National Taiwan University, Taipei City, Taiwan
| |
Collapse
|
3
|
Hu G, Ye C, Zhong M, Lei C, Qin J, Wang L. IVIM parameters mapping with artificial neural network based on mean deviation prior. Med Phys 2024. [PMID: 39241221 DOI: 10.1002/mp.17383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 07/29/2024] [Accepted: 08/12/2024] [Indexed: 09/08/2024] Open
Abstract
BACKGROUND The diffusion and perfusion parameters derived from intravoxel incoherent motion (IVIM) imaging provide promising biomarkers for noninvasively quantifying and managing various diseases. Nevertheless, due to the distribution gap between simulated and real datasets, the out-of-distribution (OOD) problem occurred in supervised learning-based methods degrades their performance and hinders their real applications. PURPOSE To address the OOD problem in supervised methods and to further improve the accuracy and stability of IVIM parameter estimation, this work proposes a novel learning framework called IterANN, based on mean deviation prior (MDP) between training and estimated IVIM parameters on the test set. METHODS Specifically, MDP indicates that the mean of the estimated IVIM parameters always locates between the mean of IVIM parameters in the test and train sets. In IterANN, we adopt a very simple artificial neural network (ANN) architecture of two hidden layers with 12 neurons per hidden layer, an input layer containing the signals acquired at multiple b-values and an output layer composed of three IVIM parameters ( D $D$ , F $F$ andD S t a r $DStar$ ). Inspired by MDP, the distribution of IVIM parameters in the training set (simulated data) is iteratively updated so that their mean gradually approaches the predicted values of the real data. This aims to achieve a strong correlation between the simulated data and the real data. To validate the effectiveness of IterANN, we compare it with several methods on both simulation and real acquisition datasets, including 21 healthy and 3 tumor subjects, in terms of residual errors of IVIM parameters or DW signals, the coefficients of variation (CV) of IVIM parameters, and the parameter contrast-to-noise ratio (PCNR) between normal and tumor tissues. RESULTS On two simulation datasets, the proposed IterANN achieves the lowest residual error in IVIM parameters, especially in the case of low signal-to-noise ratio (SNR = 10), the residual error of D $D$ , F $F$ andD S t a r $DStar$ is decreased by15.82 % / 14.92 % , 81.19 % / 74.04 % , 50.77 % / 1.549 % $15.82\%/14.92\%, 81.19\%/74.04\%, 50.77\%/1.549\%$ (Gaussian distribution /realistic distribution) respectively comparing to the suboptimal method. On real dataset, the IterANN achieves the highest PCNR when comparing the normal and tumor regions. Additionally, the proposed IterANN demonstrated better stability, with its CV being significantly lower than that of other methods in the vast majority of cases (p < 0.01 $p<0.01$ , paired-sample Student's t-test). CONCLUSIONS The superior performance of IterANN demonstrates that updating the distribution of the train set based on MDP can effectively solve the OOD problem, which allows us not only to improve the accuracy and stability of the estimated IVIM parameters, but also to increase the potential of IVIM in disease diagnosis.
Collapse
Affiliation(s)
- Guodong Hu
- Engineering Research Center of Text Computing & Cognitive Intelligence, Ministry of Education, Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, China
| | - Chen Ye
- Engineering Research Center of Text Computing & Cognitive Intelligence, Ministry of Education, Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, China
| | - Ming Zhong
- Department of Radiology, International Exemplary Cooperation Base of Precision Imaging for Diagnosis and Treatment, NHC Key Laboratory of Pulmonary Immune-related Diseases, Guizhou Provincial People's Hospital, Guiyang, China
| | - Chao Lei
- Engineering Research Center of Text Computing & Cognitive Intelligence, Ministry of Education, Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, China
| | - Junpeng Qin
- Engineering Research Center of Text Computing & Cognitive Intelligence, Ministry of Education, Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, China
| | - Lihui Wang
- Engineering Research Center of Text Computing & Cognitive Intelligence, Ministry of Education, Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, China
| |
Collapse
|
4
|
Bolan PJ, Saunders SL, Kay K, Gross M, Akcakaya M, Metzger GJ. Improved quantitative parameter estimation for prostate T 2 relaxometry using convolutional neural networks. MAGMA (NEW YORK, N.Y.) 2024; 37:721-735. [PMID: 39042205 PMCID: PMC11417079 DOI: 10.1007/s10334-024-01186-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 05/01/2024] [Accepted: 07/02/2024] [Indexed: 07/24/2024]
Abstract
OBJECTIVE Quantitative parameter mapping conventionally relies on curve fitting techniques to estimate parameters from magnetic resonance image series. This study compares conventional curve fitting techniques to methods using neural networks (NN) for measuring T2 in the prostate. MATERIALS AND METHODS Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Four combinations of different NN architectures and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. RESULTS In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst the methods. On in vivo data, this best performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. DISCUSSION This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.
Collapse
Affiliation(s)
- Patrick J Bolan
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, MN, 55455, USA.
- Department of Radiology, University of Minnesota, Minneapolis, MN, USA.
| | - Sara L Saunders
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Kendrick Kay
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, MN, 55455, USA
- Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| | - Mitchell Gross
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Mehmet Akcakaya
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, MN, 55455, USA
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
| | - Gregory J Metzger
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, MN, 55455, USA
- Department of Radiology, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
5
|
Li Z, Li Z, Bilgic B, Lee H, Ying K, Huang SY, Liao H, Tian Q. DIMOND: DIffusion Model OptimizatioN with Deep Learning. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307965. [PMID: 38634608 PMCID: PMC11200022 DOI: 10.1002/advs.202307965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 02/09/2024] [Indexed: 04/19/2024]
Abstract
Diffusion magnetic resonance imaging is an important tool for mapping tissue microstructure and structural connectivity non-invasively in the in vivo human brain. Numerous diffusion signal models are proposed to quantify microstructural properties. Nonetheless, accurate estimation of model parameters is computationally expensive and impeded by image noise. Supervised deep learning-based estimation approaches exhibit efficiency and superior performance but require additional training data and may be not generalizable. A new DIffusion Model OptimizatioN framework using physics-informed and self-supervised Deep learning entitled "DIMOND" is proposed to address this problem. DIMOND employs a neural network to map input image data to model parameters and optimizes the network by minimizing the difference between the input acquired data and synthetic data generated via the diffusion model parametrized by network outputs. DIMOND produces accurate diffusion tensor imaging results and is generalizable across subjects and datasets. Moreover, DIMOND outperforms conventional methods for fitting sophisticated microstructural models including the kurtosis and NODDI model. Importantly, DIMOND reduces NODDI model fitting time from hours to minutes, or seconds by leveraging transfer learning. In summary, the self-supervised manner, high efficacy, and efficiency of DIMOND increase the practical feasibility and adoption of microstructure and connectivity mapping in clinical and neuroscientific applications.
Collapse
Affiliation(s)
- Zihan Li
- School of Biomedical EngineeringTsinghua UniversityBeijing100084P. R. China
| | - Ziyu Li
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordOX3 9DUUK
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical ImagingMassachusetts General HospitalCharlestownMA02129USA
- Harvard Medical SchoolBostonMA02129USA
| | - Hong‐Hsi Lee
- Athinoula A. Martinos Center for Biomedical ImagingMassachusetts General HospitalCharlestownMA02129USA
- Harvard Medical SchoolBostonMA02129USA
| | - Kui Ying
- Department of Engineering PhysicsTsinghua UniversityBeijing100084P. R. China
| | - Susie Y. Huang
- Athinoula A. Martinos Center for Biomedical ImagingMassachusetts General HospitalCharlestownMA02129USA
- Harvard Medical SchoolBostonMA02129USA
| | - Hongen Liao
- School of Biomedical EngineeringTsinghua UniversityBeijing100084P. R. China
| | - Qiyuan Tian
- School of Biomedical EngineeringTsinghua UniversityBeijing100084P. R. China
| |
Collapse
|
6
|
Basukala D, Mikheev A, Sevilimedu V, Gilani N, Moy L, Pinker-Domenig K, Thakur SB, Sigmund EE. Multisite MRI Intravoxel Incoherent Motion Repeatability and Reproducibility across 3 T Scanners in a Breast Diffusion Phantom: A BReast Intravoxel Incoherent Motion Multisite (BRIMM) Study. J Magn Reson Imaging 2024; 59:2226-2237. [PMID: 37702382 PMCID: PMC10932866 DOI: 10.1002/jmri.29008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 08/28/2023] [Accepted: 08/29/2023] [Indexed: 09/14/2023] Open
Abstract
BACKGROUND Monoexponential apparent diffusion coefficient (ADC) and biexponential intravoxel incoherent motion (IVIM) analysis of diffusion-weighted imaging is helpful in the characterization of breast tumors. However, repeatability/reproducibility studies across scanners and across sites are scarce. PURPOSE To evaluate the repeatability and reproducibility of ADC and IVIM parameters (tissue diffusivity (Dt), perfusion fraction (Fp) and pseudo-diffusion (Dp)) within and across sites employing MRI scanners from different vendors utilizing 16-channel breast array coils in a breast diffusion phantom. STUDY TYPE Phantom repeatability. PHANTOM A breast phantom containing tubes of different polyvinylpyrrolidone (PVP) concentrations, water, fat, and sponge flow chambers, together with an MR-compatible liquid crystal (LC) thermometer. FIELD STRENGTH/SEQUENCE Bipolar gradient twice-refocused spin echo sequence and monopolar gradient single spin echo sequence at 3 T. ASSESSMENT Studies were performed twice in each of two scanners, located at different sites, on each of 2 days, resulting in four studies per scanner. ADCs of the PVP and water were normalized to the vendor-provided calibrated values at the temperature indicated by the LC thermometer for repeatability/reproducibility comparisons. STATISTICAL TESTS ADC and IVIM repeatability and reproducibility within and across sites were estimated via the within-system coefficient of variation (wCV). Pearson correlation coefficient (r) was also computed between IVIM metrics and flow speed. A P value <0.05 was considered statistically significant. RESULTS ADC and Dt demonstrated excellent repeatability (<2%; <3%, respectively) and reproducibility (both <5%) at the two sites. Fp and Dp exhibited good repeatability (mean of two sites 3.67% and 5.59%, respectively) and moderate reproducibility (mean of two sites 15.96% and 13.3%, respectively). The mean intersite reproducibility (%) of Fp/Dp/Dt was 50.96/13.68/5.59, respectively. Fp and Dt demonstrated high correlations with flow speed while Dp showed lower correlations. Fp correlations with flow speed were significant at both sites. DATA CONCLUSION IVIM reproducibility results were promising and similar to ADC, particularly for Dt. The results were reproducible within both sites, and a progressive trend toward reproducibility across sites except for Fp. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Dibash Basukala
- Center for Advanced Imaging and Innovation (CAIR), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Artem Mikheev
- Center for Advanced Imaging and Innovation (CAIR), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Varadan Sevilimedu
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Nima Gilani
- Center for Advanced Imaging and Innovation (CAIR), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Linda Moy
- Center for Advanced Imaging and Innovation (CAIR), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| | - Katja Pinker-Domenig
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Sunitha B. Thakur
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Eric E. Sigmund
- Center for Advanced Imaging and Innovation (CAIR), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, New York, USA
| |
Collapse
|
7
|
Liu K, Lin Z, Zheng T, Ba R, Zhang Z, Li H, Zhang H, Tal A, Wu D. Improving Microstructural Estimation in Time-Dependent Diffusion MRI With a Bayesian Method. J Magn Reson Imaging 2024. [PMID: 38769739 DOI: 10.1002/jmri.29434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 04/20/2024] [Accepted: 04/22/2024] [Indexed: 05/22/2024] Open
Abstract
BACKGROUND Accurately fitting diffusion-time-dependent diffusion MRI (td-dMRI) models poses challenges due to complex and nonlinear formulas, signal noise, and limited clinical data acquisition. PURPOSE Introduce a Bayesian methodology to refine microstructural fitting within the IMPULSED (Imaging Microstructural Parameters Using Limited Spectrally Edited Diffusion) model and optimize the prior distribution within the Bayesian framework. STUDY TYPE Retrospective. POPULATION Involving 69 pediatric patients (median age 6 years, interquartile range [IQR] 3-9 years, 61% male) with 41 low-grade and 28 high-grade gliomas, of which 76.8% were identified within the brainstem or cerebellum. FIELD STRENGTH/SEQUENCE 3 T, oscillating gradient spin-echo (OGSE) and pulsed gradient spin-echo (PGSE). ASSESSMENT The Bayesian method's performance in fitting cell diameter (d $$ d $$ ), intracellular volume fraction (f in $$ {f}_{in} $$ ), and extracellular diffusion coefficient (D ex $$ {D}_{ex} $$ ) was compared against the NLLS method, considering simulated and experimental data. The tumor region-of-interest (ROI) were manually delineated on the b0 images. The diagnostic performance in distinguishing high- and low-grade gliomas was assessed, and fitting accuracy was validated against H&E-stained pathology. STATISTICAL TESTS T-test, receiver operating curve (ROC), area under the curve (AUC) and DeLong's test were conducted. Significance considered at P < 0.05. RESULTS Bayesian methodology manifested increased accuracy with robust estimates in simulation (RMSE decreased by 29.6%, 40.9%, 13.6%, and STD decreased by 29.2%, 43.5%, and 24.0%, respectively ford $$ d $$ ,f in $$ {f}_{in} $$ , andD ex $$ {D}_{ex} $$ compared to NLLS), indicating fewer outliers and reduced error. Diagnostic performance for tumor grade was similar in both methods, however, Bayesian method generated smoother microstructural maps (outliers ratio decreased by 45.3% ± 19.4%) and a marginal enhancement in correlation with H&E staining result (r = 0.721 forf in $$ {f}_{in} $$ compared to r = 0.698 using NLLS, P = 0.5764). DATA CONCLUSION The proposed Bayesian method substantially enhances the accuracy and robustness of IMPULSED model estimation, suggesting its potential clinical utility in characterizing cellular microstructure. EVIDENCE LEVEL 3 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Kuiyuan Liu
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Zixuan Lin
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Tianshu Zheng
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Ruicheng Ba
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Zelin Zhang
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Haotian Li
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Hongxi Zhang
- Department of Radiology, Children's Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Assaf Tal
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Dan Wu
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
- Department of Radiology, Children's Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
8
|
Sharifzadeh Javidi S, Ahadi R, Saligheh Rad H. Improving Accuracy of Intravoxel Incoherent Motion Reconstruction using Kalman Filter in Combination with Neural Networks: A Simulation Study. J Biomed Phys Eng 2024; 14:141-150. [PMID: 38628891 PMCID: PMC11016822 DOI: 10.31661/jbpe.v0i0.2104-1313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 06/16/2021] [Indexed: 04/19/2024]
Abstract
Background The intravoxel Incoherent Motion (IVIM) model extracts perfusion map and diffusion coefficient map using diffusion-weighted imaging. The main limitation of this model is inaccuracy in the presence of noise. Objective This study aims to improve the accuracy of IVIM output parameters. Material and Methods In this simulated and analytical study, the Kalman filter is applied to reject artifact and measurement noise. The proposed method purifies the diffusion coefficient from blood motion and noise, and then an artificial neural network is deployed in estimating perfusion parameters. Results Based on the T-test results, however, the estimated parameters of the conventional method were significantly different from actual values, those of the proposed method were not substantially different from actual. The accuracy of f and D* also was improved by using Artificial Neural Network (ANN) and their bias was minimized to 4% and 12%, respectively. Conclusion The proposed method outperforms the conventional method and is a promising technique, leading to reproducible and valid maps of D, f, and D*.
Collapse
Affiliation(s)
- Sam Sharifzadeh Javidi
- Department of Physics and Medical Engineering, Medicine School, Tehran University of Medical Sciences, Tehran, Iran
- Quantitative Medical Imaging Systems Group, Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
| | - Reza Ahadi
- Department of Anatomy, Medicine School, Iran University of Medical Sciences, Tehran, Iran
| | - Hamidreza Saligheh Rad
- Department of Physics and Medical Engineering, Medicine School, Tehran University of Medical Sciences, Tehran, Iran
- Quantitative Medical Imaging Systems Group, Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
9
|
Prieto-González LS, Agulles-Pedrós L. Exploring the Potential of Machine Learning Algorithms to Improve Diffusion Nuclear Magnetic Resonance Imaging Models Analysis. J Med Phys 2024; 49:189-202. [PMID: 39131437 PMCID: PMC11309135 DOI: 10.4103/jmp.jmp_10_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 03/27/2024] [Accepted: 04/15/2024] [Indexed: 08/13/2024] Open
Abstract
Purpose This paper explores different machine learning (ML) algorithms for analyzing diffusion nuclear magnetic resonance imaging (dMRI) models when analytical fitting shows restrictions. It reviews various ML techniques for dMRI analysis and evaluates their performance on different b-values range datasets, comparing them with analytical methods. Materials and Methods After standard fitting for reference, four sets of diffusion-weighted nuclear magnetic resonance images were used to train/test various ML algorithms for prediction of diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (f), and kurtosis (K). ML classification algorithms, including extra-tree classifier (ETC), logistic regression, C-support vector, extra-gradient boost, and multilayer perceptron (MLP), were used to determine the existence of diffusion parameters (D, D*, f, and K) within single voxels. Regression algorithms, including linear regression, polynomial regression, ridge, lasso, random forest (RF), elastic-net, and support-vector machines, were used to estimate the value of the diffusion parameters. Performance was evaluated using accuracy (ACC), area under the curve (AUC) tests, and cross-validation root mean square error (RMSECV). Computational timing was also assessed. Results ETC and MLP were the best classifiers, with 94.1% and 91.7%, respectively, for the ACC test and 98.7% and 96.3% for the AUC test. For parameter estimation, RF algorithm yielded the most accurate results The RMSECV percentages were: 8.39% for D, 3.57% for D*, 4.52% for f, and 3.53% for K. After the training phase, the ML methods demonstrated a substantial decrease in computational time, being approximately 232 times faster than the conventional methods. Conclusions The findings suggest that ML algorithms can enhance the efficiency of dMRI model analysis and offer new perspectives on the microstructural and functional organization of biological tissues. This paper also discusses the limitations and future directions of ML-based dMRI analysis.
Collapse
Affiliation(s)
| | - Luis Agulles-Pedrós
- Department of Physics, Medical Physics Group, National University of Colombia, Campus Bogotá, Bogotá, Colombia
| |
Collapse
|
10
|
Lebret A, Lévy S, Pfender N, Farshad M, Altorfer FCS, Callot V, Curt A, Freund P, Seif M. Investigation of perfusion impairment in degenerative cervical myelopathy beyond the site of cord compression. Sci Rep 2023; 13:22660. [PMID: 38114733 PMCID: PMC10730822 DOI: 10.1038/s41598-023-49896-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 12/13/2023] [Indexed: 12/21/2023] Open
Abstract
The aim of this study was to determine tissue-specific blood perfusion impairment of the cervical cord above the compression site in patients with degenerative cervical myelopathy (DCM) using intravoxel incoherent motion (IVIM) imaging. A quantitative MRI protocol, including structural and IVIM imaging, was conducted in healthy controls and patients. In patients, T2-weighted scans were acquired to quantify intramedullary signal changes, the maximal canal compromise, and the maximal cord compression. T2*-weighted MRI and IVIM were applied in all participants in the cervical cord (covering C1-C3 levels) to determine white matter (WM) and grey matter (GM) cross-sectional areas (as a marker of atrophy), and tissue-specific perfusion indices, respectively. IVIM imaging resulted in microvascular volume fraction ([Formula: see text]), blood velocity ([Formula: see text]), and blood flow ([Formula: see text]) indices. DCM patients additionally underwent a standard neurological clinical assessment. Regression analysis assessed associations between perfusion parameters, clinical outcome measures, and remote spinal cord atrophy. Twenty-nine DCM patients and 30 healthy controls were enrolled in the study. At the level of stenosis, 11 patients showed focal radiological evidence of cervical myelopathy. Above the stenosis level, cord atrophy was observed in the WM (- 9.3%; p = 0.005) and GM (- 6.3%; p = 0.008) in patients compared to healthy controls. Blood velocity (BV) and blood flow (BF) indices were decreased in the ventral horns of the GM (BV: - 20.1%, p = 0.0009; BF: - 28.2%, p = 0.0008), in the ventral funiculi (BV: - 18.2%, p = 0.01; BF: - 21.5%, p = 0.04) and lateral funiculi (BV: - 8.5%, p = 0.03; BF: - 16.5%, p = 0.03) of the WM, across C1-C3 levels. A decrease in microvascular volume fraction was associated with GM atrophy (R = 0.46, p = 0.02). This study demonstrates tissue-specific cervical perfusion impairment rostral to the compression site in DCM patients. IVIM indices are sensitive to remote perfusion changes in the cervical cord in DCM and may serve as neuroimaging biomarkers of hemodynamic impairment in future studies. The association between perfusion impairment and cervical cord atrophy indicates that changes in hemodynamics caused by compression may contribute to the neurodegenerative processes in DCM.
Collapse
Affiliation(s)
- Anna Lebret
- Spinal Cord Injury Center, Balgrist University Hospital, Zürich, Switzerland
| | - Simon Lévy
- CNRS, CRMBM, Aix-Marseille University, Marseille, France
- APHM, CEMEREM, Hôpital Universitaire Timone, Marseille, France
- MR Research Collaborations, Siemens Healthcare Pty Ltd, Melbourne, Australia
| | - Nikolai Pfender
- Spinal Cord Injury Center, Balgrist University Hospital, Zürich, Switzerland
| | - Mazda Farshad
- Department of Orthopedic Surgery, Balgrist University Hospital, Zürich, Switzerland
| | | | - Virginie Callot
- CNRS, CRMBM, Aix-Marseille University, Marseille, France
- APHM, CEMEREM, Hôpital Universitaire Timone, Marseille, France
| | - Armin Curt
- Spinal Cord Injury Center, Balgrist University Hospital, Zürich, Switzerland
| | - Patrick Freund
- Spinal Cord Injury Center, Balgrist University Hospital, Zürich, Switzerland
- Department of Brain Repair and Rehabilitation, Wellcome Trust Center for Neuroimaging, Institute of Neurology, University College London, London, UK
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Maryam Seif
- Spinal Cord Injury Center, Balgrist University Hospital, Zürich, Switzerland.
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
| |
Collapse
|
11
|
Sharifzadeh Javidi S, Shirazinodeh A, Saligheh Rad H. Intravoxel Incoherent Motion Quantification Dependent on Measurement SNR and Tissue Perfusion: A Simulation Study. J Biomed Phys Eng 2023; 13:555-562. [PMID: 38148961 PMCID: PMC10749416 DOI: 10.31661/jbpe.v0i0.2102-1281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Accepted: 03/28/2021] [Indexed: 12/28/2023]
Abstract
Background The intravoxel incoherent motion (IVIM) model extracts both functional and structural information of a tissue using motion-sensitizing gradients. Objective The Objective of the present work is to investigate the impact of signal to noise ratio (SNR) and physiologic conditions on the validity of IVIM parameters. Material and Methods This study is a simulation study, modeling IVIM at a voxel, and also done 10,000 times for every single simulation. Complex noises with various standard deviations were added to signal in-silico to investigate SNR effects on output validity. Besides, some blood perfusion situations for different tissues were considered based on their physiological range to explore the impacts of blood fraction at each voxel on the validity of the IVIM outputs. Coefficient variation (CV) and bias of the estimations were computed to assess the validity of the IVIM parameters. Results This study has shown that the validity of IVIM output parameters highly depends on measurement SNR and physiologic characteristics of the studied organ. Conclusion IVIM imaging could be useful if imaging parameters are correctly selected for each specific organ, considering hardware limitations.
Collapse
Affiliation(s)
- Sam Sharifzadeh Javidi
- Department of Medical Physics and Biomedical Engineering, Medicine School, Tehran University of Medical Sciences, Tehran, Iran
- Quantitative Medical Imaging Systems Group, Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
| | - Alireza Shirazinodeh
- Department of Medical Physics and Biomedical Engineering, Medicine School, Tehran University of Medical Sciences, Tehran, Iran
| | - Hamidreza Saligheh Rad
- Department of Medical Physics and Biomedical Engineering, Medicine School, Tehran University of Medical Sciences, Tehran, Iran
- Quantitative Medical Imaging Systems Group, Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
12
|
Bolan PJ, Saunders SL, Kay K, Gross M, Akcakaya M, Metzger GJ. Improved Quantitative Parameter Estimation for Prostate T2 Relaxometry using Convolutional Neural Networks. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.01.11.23284194. [PMID: 36711813 PMCID: PMC9882442 DOI: 10.1101/2023.01.11.23284194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
This work seeks to evaluate multiple methods for quantitative parameter estimation from standard T2 mapping acquisitions in the prostate. The T2 estimation performance of methods based on neural networks (NN) was quantitatively compared to that of conventional curve fitting techniques. Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Ten combinations of different NN architectures, training strategies, and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst all the methods. On in vivo data, this best-performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.
Collapse
Affiliation(s)
- Patrick J Bolan
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis MN
- Department of Radiology, University of Minnesota, Minneapolis MN
| | - Sara L Saunders
- Department of Biomedical Engineering, University of Minnesota, Minneapolis MN
| | - Kendrick Kay
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis MN
- Department of Radiology, University of Minnesota, Minneapolis MN
| | - Mitchell Gross
- Department of Biomedical Engineering, University of Minnesota, Minneapolis MN
| | - Mehmet Akcakaya
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis MN
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis MN
| | - Gregory J Metzger
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis MN
- Department of Radiology, University of Minnesota, Minneapolis MN
| |
Collapse
|
13
|
Kaandorp MPT, Zijlstra F, Federau C, While PT. Deep learning intravoxel incoherent motion modeling: Exploring the impact of training features and learning strategies. Magn Reson Med 2023; 90:312-328. [PMID: 36912473 DOI: 10.1002/mrm.29628] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 02/14/2023] [Accepted: 02/16/2023] [Indexed: 03/14/2023]
Abstract
PURPOSE The development of advanced estimators for intravoxel incoherent motion (IVIM) modeling is often motivated by a desire to produce smoother parameter maps than least squares (LSQ). Deep neural networks show promise to this end, yet performance may be conditional on a myriad of choices regarding the learning strategy. In this work, we have explored potential impacts of key training features in unsupervised and supervised learning for IVIM model fitting. METHODS Two synthetic data sets and one in-vivo data set from glioma patients were used in training of unsupervised and supervised networks for assessing generalizability. Network stability for different learning rates and network sizes was assessed in terms of loss convergence. Accuracy, precision, and bias were assessed by comparing estimations against ground truth after using different training data (synthetic and in vivo). RESULTS A high learning rate, small network size, and early stopping resulted in sub-optimal solutions and correlations in fitted IVIM parameters. Extending training beyond early stopping resolved these correlations and reduced parameter error. However, extensive training resulted in increased noise sensitivity, where unsupervised estimates displayed variability similar to LSQ. In contrast, supervised estimates demonstrated improved precision but were strongly biased toward the mean of the training distribution, resulting in relatively smooth, yet possibly deceptive parameter maps. Extensive training also reduced the impact of individual hyperparameters. CONCLUSION Voxel-wise deep learning for IVIM fitting demands sufficiently extensive training to minimize parameter correlation and bias for unsupervised learning, or demands a close correspondence between the training and test sets for supervised learning.
Collapse
Affiliation(s)
- Misha P T Kaandorp
- Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway.,Department of Circulation and Medical Imaging, NTNU - Norwegian University of Science and Technology, Trondheim, Norway
| | - Frank Zijlstra
- Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway.,Department of Circulation and Medical Imaging, NTNU - Norwegian University of Science and Technology, Trondheim, Norway
| | - Christian Federau
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.,AI Medical, Zurich, Switzerland
| | - Peter T While
- Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway.,Department of Circulation and Medical Imaging, NTNU - Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
14
|
Huang H, Liu B, Xu Y, Zhou W. Synthetic-to-real domain adaptation with deep learning for fitting the intravoxel incoherent motion model of diffusion-weighted imaging. Med Phys 2023; 50:1614-1622. [PMID: 36308503 DOI: 10.1002/mp.16031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 10/03/2022] [Accepted: 10/03/2022] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND Intravoxel incoherent motion (IVIM) is a type of diffusion-weighted imaging (DWI), and IVIM model parameters (water molecule diffusion rate Dt , pseudo-diffusion coefficient Dp , and tissue perfusion fraction Fp ) have been widely used in the diagnosis and characterization of malignant lesions. PURPOSE This study proposes a deep-learning model with synthetic-to-real domain adaptation to fit the IVIM model parameters of DWI. METHODS Ninety-eight consecutive patients diagnosed with hepatocellular carcinoma between January 2017 and September 2020 were included in the study, and routine IVIM-DWI serial examinations were performed using a 3.0 T magnetic resonance imaging system in preoperative MR imaging. The proposed method is mainly composed of two modules: a convolutional neural network-based IVIM model fitting network to map b-value images to the IVIM parameter maps and a domain discriminator to improve the accuracy of the IVIM parameter maps in the real data. The proposed method was compared with previously reported fitting methods, including the nonlinear least squares (NLSs), IVIM-NEToptim , and self-supervised U-network methods. The IVIM parameter-fitting performance was assessed by measuring the DWI reconstruction performance and testing the robustness of each method against noise using noise-corrupted data. RESULTS The DWI reconstruction performance demonstrates that the proposed method has better reconstruction accuracy for DWI with a low signal-to-noise ratio, which implies that the proposed method improves the fitting accuracy of the IVIM parameters. Noise-corrupt experiments show that the proposed method is more robust against noise-corrupted signals. With the proposed method, no outliers were found in Dt , and outliers were reduced for Fp in the abnormal regions (proposed method: 1.85%; NLS: 5.90%; IVIM-NEToptim : 6.61%; and self-U-net: 25.36%). Moreover, experiments show that the proposed method has a more stable parameter estimation performance than the existing methods in the absence of real data. CONCLUSIONS IVIM parameters can be estimated using a synthetic-to-real domain-adaptation framework with deep learning, and the proposed method outperforms previously reported methods.
Collapse
Affiliation(s)
- Haoyuan Huang
- School of Medical Information Engineering, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Baoer Liu
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yikai Xu
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Wu Zhou
- School of Medical Information Engineering, Guangzhou University of Chinese Medicine, Guangzhou, China
| |
Collapse
|
15
|
Diao Y, Jelescu I. Parameter estimation for WMTI-Watson model of white matter using encoder-decoder recurrent neural network. Magn Reson Med 2023; 89:1193-1206. [PMID: 36372982 DOI: 10.1002/mrm.29495] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 09/26/2022] [Accepted: 09/29/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE Biophysical modeling of the diffusion MRI (dMRI) signal provides estimates of specific microstructural tissue properties. Although non-linear least squares (NLLS) is the most widespread fitting method, it suffers from local minima and high computational cost. Deep learning approaches are steadily replacing NLLS, but come with the limitation that the model needs to be retrained for each acquisition protocol and noise level. In this study, a novel fitting approach was proposed based on the encoder-decoder recurrent neural network (RNN) to accelerate model estimation with good generalization to various datasets. METHODS The white matter tract integrity (WMTI)-Watson model as an implementation of the Standard Model of diffusion in white matter derives its parameters indirectly from the diffusion and kurtosis tensors (DKI). The RNN-based solver, which estimates the WMTI-Watson model from DKI, is therefore more readily translatable to various data, irrespective of acquisition protocols as long as the DKI was pre-computed from the signal. An embedding approach was also used to render the model insensitive to potential differences in distributions between training data and experimental data. The analytical solution, NLLS, RNN-, and a multilayer perceptron (MLP)-based methods were evaluated on synthetic and in vivo datasets of rat and human brain. RESULTS The proposed RNN solver showed highly reduced computation time over the analytical solution and NLLS, with similar accuracy but improved robustness, and superior generalizability over MLP. CONCLUSION The RNN estimator can be easily applied to various datasets without retraining, which shows great potential for a widespread use.
Collapse
Affiliation(s)
- Yujian Diao
- Laboratory of Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.,CIBM Center for Biomedical Imaging, Lausanne, Switzerland
| | - Ileana Jelescu
- Department of Radiology, Lausanne University Hospital, Lausanne, Switzerland
| |
Collapse
|
16
|
Scalco E, Rizzo G, Mastropietro A. The quantification of IntraVoxel incoherent motion - MRI maps cannot preserve texture information: An evaluation based on simulated and in-vivo images. Comput Biol Med 2023; 154:106495. [PMID: 36669333 DOI: 10.1016/j.compbiomed.2022.106495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 12/15/2022] [Accepted: 12/27/2022] [Indexed: 01/18/2023]
Abstract
BACKGROUND Radiomics can be applied on parametric maps obtained from IntraVoxel Incoherent Motion (IVIM) MRI to characterize heterogeneity in diffusion and perfusion tissue properties. The purpose of this work is to assess the accuracy and reproducibility of radiomic features computed from IVIM maps using different fitting methods. METHODS 200 digitally simulated IVIM-MRI images with various SNR containing different combinations of texture patterns were generated from ground truth maps of true diffusion D, pseudo-diffusion D* and perfusion fraction f. Four different methods (segmented least-square LSQ, Bayesian, supervised and unsupervised deep learning DL) were adopted to quantify IVIM maps from simulations and from two real images of liver tumor. Radiomic features were computed from ground truth and estimated maps. Accuracy and reproducibility among quantification methods were assessed. RESULTS Almost 50% of radiomic features computed from D maps using DL approaches, 36% using Bayes and 27% using LSQ presented errors lower than 50%. Radiomic features from f and D* maps were accurate only if computed using DL methods from histogram. High reproducibility (ICC>0.8) was found only for D maps among DL and Bayes methods, whereas features from f and D* maps were less reproducible, with LSQ approach in lower agreement with the others. CONCLUSIONS Texture patterns were preserved and correctly estimated only on D maps, except for LSQ approach. We suggest limiting radiomic analysis only to histogram and some texture features from D maps, to histogram features from f maps, and to avoid it on D* maps.
Collapse
Affiliation(s)
- Elisa Scalco
- Institute for Biomedical Technologies, National Research Council (ITB-CNR), Segrate, MI, Italy.
| | - Giovanna Rizzo
- Institute for Biomedical Technologies, National Research Council (ITB-CNR), Segrate, MI, Italy
| | - Alfonso Mastropietro
- Institute for Biomedical Technologies, National Research Council (ITB-CNR), Segrate, MI, Italy
| |
Collapse
|
17
|
Stabinska J, Zöllner HJ, Thiel TA, Wittsack HJ, Ljimani A. Image downsampling expedited adaptive least-squares (IDEAL) fitting improves intravoxel incoherent motion (IVIM) analysis in the human kidney. Magn Reson Med 2023; 89:1055-1067. [PMID: 36416075 DOI: 10.1002/mrm.29517] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 10/13/2022] [Accepted: 10/14/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To improve the reliability of intravoxel incoherent motion (IVIM) model parameter estimation for the DWI in the kidney using a novel image downsampling expedited adaptive least-squares (IDEAL) approach. METHODS The robustness of IDEAL was investigated using simulated DW-MRI data corrupted with different levels of Rician noise. Subsequently, the performance of the proposed method was tested by fitting bi- and triexponential IVIM model to in vivo renal DWI data acquired on a clinical 3 Tesla MRI scanner and compared to conventional approaches (fixed D* and segmented fitting). RESULTS The numerical simulations demonstrated that the IDEAL algorithm provides robust estimates of the IVIM parameters in the presence of noise (SNR of 20) as indicated by relatively low absolute percentage bias (maximal sMdPB <20%) and normalized RMSE (maximal RMSE <28%). The analysis of the in vivo data showed that the IDEAL-based IVIM parameter maps were less noisy and more visually appealing than those obtained using the fixed D* and segmented methods. Further, coefficients of variation for nearly all IVIM parameters were significantly reduced in cortex and medulla for IDEAL-based biexponential (coefficients of variation: 4%-50%) and triexponential (coefficients of variation: 7.5%-75%) IVIM modelling compared to the segmented (coefficients of variation: 4%-120%) and fixed D* (coefficients of variation: 17%-174%) methods, reflecting greater accuracy of this method. CONCLUSION The proposed fitting algorithm yields more robust IVIM parameter estimates and is less susceptible to poor SNR than the conventional fitting approaches. Thus, the IDEAL approach has the potential to improve the reliability of renal DW-MRI analysis for clinical applications.
Collapse
Affiliation(s)
- Julia Stabinska
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, 21205, USA
- Division of MR Research, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, 21205, USA
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich-Heine University Dusseldorf, Düsseldorf, Germany
| | - Helge J Zöllner
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, 21205, USA
- Division of MR Research, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, 21205, USA
| | - Thomas A Thiel
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich-Heine University Dusseldorf, Düsseldorf, Germany
| | - Hans-Jörg Wittsack
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich-Heine University Dusseldorf, Düsseldorf, Germany
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich-Heine University Dusseldorf, Düsseldorf, Germany
| |
Collapse
|
18
|
Huang HM. An unsupervised convolutional neural network method for estimation of intravoxel incoherent motion parameters. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac9a1f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 10/13/2022] [Indexed: 11/07/2022]
Abstract
Abstract
Objective. Intravoxel incoherent motion (IVIM) imaging obtained by fitting a biexponential model to multiple b-value diffusion-weighted magnetic resonance imaging (DW-MRI) has been shown to be a promising tool for different clinical applications. Recently, several deep neural network (DNN) methods were proposed to generate IVIM imaging. Approach. In this study, we proposed an unsupervised convolutional neural network (CNN) method for estimation of IVIM parameters. We used both simulated and real abdominal DW-MRI data to evaluate the performance of the proposed CNN-based method, and compared the results with those obtained from a non-linear least-squares fit (TRR, trust-region reflective algorithm) and a feed-forward backward-propagation DNN-based method. Main results. The simulation results showed that both the DNN- and CNN-based methods had lower coefficients of variation than the TRR method, but the CNN-based method provided more accurate parameter estimates. The results obtained from real DW-MRI data showed that the TRR method produced many biased IVIM parameter estimates that hit the upper and lower parameter bounds. In contrast, both the DNN- and CNN-based methods yielded less biased IVIM parameter estimates. Overall, the perfusion fraction and diffusion coefficient obtained from the DNN- and CNN-based methods were close to literature values. However, compared with the CNN-based method, both the TRR and DNN-based methods tended to yield increased pseudodiffusion coefficients (55%–180%). Significance. Our preliminary results suggest that it is feasible to estimate IVIM parameters using CNN.
Collapse
|
19
|
Gurney-Champion OJ, Landry G, Redalen KR, Thorwarth D. Potential of Deep Learning in Quantitative Magnetic Resonance Imaging for Personalized Radiotherapy. Semin Radiat Oncol 2022; 32:377-388. [DOI: 10.1016/j.semradonc.2022.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
20
|
Mastropietro A, Procissi D, Scalco E, Rizzo G, Bertolino N. A supervised deep neural network approach with standardized targets for enhanced accuracy of IVIM parameter estimation from multi-SNR images. NMR IN BIOMEDICINE 2022; 35:e4774. [PMID: 35587618 PMCID: PMC9539583 DOI: 10.1002/nbm.4774] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 05/16/2022] [Accepted: 05/16/2022] [Indexed: 06/15/2023]
Abstract
Extraction of intravoxel incoherent motion (IVIM) parameters from noisy diffusion-weighted (DW) images using a biexponential fitting model is computationally challenging, and the reliability of the estimated perfusion-related quantities represents a limitation of this technique. Artificial intelligence can overcome the current limitations and be a suitable solution to advance use of this technique in both preclinical and clinical settings. The purpose of this work was to develop a deep neural network (DNN) approach, trained on numerical simulated phantoms with different signal to noise ratios (SNRs), to improve IVIM parameter estimation. The proposed approach is based on a supervised fully connected DNN having 3 hidden layers, 18 inputs and 3 targets with standardized values. 14 × 103 simulated DW images, based on a Shepp-Logan phantom, were randomly generated with varying SNRs (ranging from 10 to 100). 7 × 103 images (1000 for each SNR) were used for training. Performance accuracy was assessed in simulated images and the proposed approach was compared with the state-of-the-art Bayesian approach and other DNN algorithms. The DNN approach was also evaluated in vivo on a high-field MRI preclinical scanner. Our DNN approach showed an overall improvement in accuracy when compared with the Bayesian approach and other DNN methods in most of the simulated conditions. The in vivo results demonstrated the feasibility of the proposed approach in real settings and generated quantitative results comparable to those obtained using the Bayesian and unsupervised approaches, especially for D and f, and with lower variability in homogeneous regions. The DNN architecture proposed in this work outlines two innovative features as compared with other studies: (1) the use of standardized targets to improve the estimation of parameters, and (2) the implementation of a single DNN to enhance the IVIM fitting at different SNRs, providing a valuable alternative tool to compute IVIM parameters in conditions of high background noise.
Collapse
Affiliation(s)
| | - Daniel Procissi
- Department of RadiologyNorthwestern UniversityChicagoIllinoisUSA
| | - Elisa Scalco
- Istituto di Tecnologie BiomedicheConsiglio Nazionale delle RicercheSegrateItaly
| | - Giovanna Rizzo
- Istituto di Tecnologie BiomedicheConsiglio Nazionale delle RicercheSegrateItaly
| | - Nicola Bertolino
- Department of RadiologyNorthwestern UniversityChicagoIllinoisUSA
| |
Collapse
|
21
|
Ishida S, Isozaki M, Fujiwara Y, Takei N, Kanamoto M, Kimura H, Tsujikawa T. Estimation of Cerebral Blood Flow and Arterial Transit Time From Multi-Delay Arterial Spin Labeling MRI Using a Simulation-Based Supervised Deep Neural Network. J Magn Reson Imaging 2022; 57:1477-1489. [PMID: 36169654 DOI: 10.1002/jmri.28433] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 08/31/2022] [Accepted: 09/01/2022] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND An inherently poor signal-to-noise ratio (SNR) causes inaccuracy and less precision in cerebral blood flow (CBF) and arterial transit time (ATT) when using arterial spin labeling (ASL). Deep neural network (DNN)-based parameter estimation can solve these problems. PURPOSE To reduce the effects of Rician noise on ASL parameter estimation and compute unbiased CBF and ATT using simulation-based supervised DNNs. STUDY TYPE Retrospective. POPULATION One million simulation test data points, 17 healthy volunteers (five women and 12 men, 33.2 ± 14.6 years of age), and one patient with moyamoya disease. FIELD STRENGTH/SEQUENCE 3.0 T/Hadamard-encoded pseudo-continuous ASL with a three-dimensional fast spin-echo stack of spirals. ASSESSMENT Performances of DNN and conventional methods were compared. For test data, the normalized mean absolute error (NMAE) and normalized root mean squared error (NRMSE) between the ground truth and predicted values were evaluated. For in vivo data, baseline CBF and ATT and their relative changes with respect to SNR using artificial noise-added images were assessed. STATISTICAL TESTS One-way analysis of variance with post-hoc Tukey's multiple comparison test, paired t-test, and the Bland-Altman graphical analysis. Statistical significance was defined as P < 0.05. RESULTS For both CBF and ATT, NMAE and NRMSE were lower with DNN than with the conventional method. The baseline values were significantly smaller with DNN than with the conventional method (CBF in gray matter, 66 ± 10 vs. 71 ± 12 mL/100 g/min; white matter, 45 ± 6 vs. 46 ± 7 mL/100 g/min; ATT in gray matter, 1424 ± 201 vs. 1471 ± 154 msec). CBF and ATT increased with decreasing SNR; however, their change rates were smaller with DNN than were those with the conventional method. Higher CBF in the prolonged ATT region and clearer contrast in ATT were identified by DNN in a clinical case. DATA CONCLUSION DNN outperformed the conventional method in terms of accuracy, precision, and noise immunity. EVIDENCE LEVEL 3 Technical Efficacy: Stage 1.
Collapse
Affiliation(s)
- Shota Ishida
- Department of Radiological Technology, Faculty of Medical Sciences, Kyoto College of Medical Science, Kyoto, Japan
| | - Makoto Isozaki
- Department of Neurosurgery, Division of Medicine, Faculty of Medical Sciences, University of Fukui, Fukui, Japan
| | - Yasuhiro Fujiwara
- Department of Medical Image Sciences, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Naoyuki Takei
- GE Healthcare, Tokyo, Japan.,Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | | | - Hirohiko Kimura
- Faculty of Medical Sciences, University of Fukui, Fukui, Japan.,Radiology Section, National Health Insurance Echizen-cho Ota Hospital, Fukui, Japan
| | - Tetsuya Tsujikawa
- Department of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan
| |
Collapse
|
22
|
Lee W, Choi G, Lee J, Park H. Registration and quantification network (RQnet) for IVIM-DKI analysis in MRI. Magn Reson Med 2022; 89:250-261. [PMID: 36121205 DOI: 10.1002/mrm.29454] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2022] [Revised: 08/22/2022] [Accepted: 08/22/2022] [Indexed: 11/08/2022]
Abstract
PURPOSE A deep learning method is proposed for aligning diffusion weighted images (DWIs) and estimating intravoxel incoherent motion-diffusion kurtosis imaging parameters simultaneously. METHODS We propose an unsupervised deep learning method that performs 2 tasks: registration and quantification for intravoxel incoherent motion-diffusion kurtosis imaging analysis. A common registration method in diffusion MRI is based on minimizing dissimilarity between various DWIs, which may result in registration errors due to different contrasts in different DWIs. We designed a novel unsupervised deep learning method for both accurate registration and quantification of various diffusion parameters. In order to generate motion-simulated training data and test data, 17 volunteers were scanned without moving their heads, and 4 volunteers moved their heads during the scan in a 3 Tesla MRI. In order to investigate the applicability of the proposed method to other organs, kidney images were also obtained. We compared the registration accuracy of the proposed method, statistical parametric mapping, and a deep learning method with a normalized cross-correlation loss. In the quantification part of the proposed method, a deep learning method that considered the diffusion gradient direction was used. RESULTS Simulations and experimental results showed that the proposed method accurately performed registration and quantification for intravoxel incoherent motion-diffusion kurtosis imaging analysis. The registration accuracy of the proposed method was high for all b values. Furthermore, quantification performance was analyzed through simulations and in vivo experiments, where the proposed method showed the best performance among the compared methods. CONCLUSION The proposed method aligns the DWIs and accurately quantifies the intravoxel incoherent motion-diffusion kurtosis imaging parameters.
Collapse
Affiliation(s)
- Wonil Lee
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Giyong Choi
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - Jongyeon Lee
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| | - HyunWook Park
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea
| |
Collapse
|
23
|
Troelstra MA, Van Dijk AM, Witjes JJ, Mak AL, Zwirs D, Runge JH, Verheij J, Beuers UH, Nieuwdorp M, Holleboom AG, Nederveen AJ, Gurney-Champion OJ. Self-supervised neural network improves tri-exponential intravoxel incoherent motion model fitting compared to least-squares fitting in non-alcoholic fatty liver disease. Front Physiol 2022; 13:942495. [PMID: 36148303 PMCID: PMC9485997 DOI: 10.3389/fphys.2022.942495] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 07/27/2022] [Indexed: 11/13/2022] Open
Abstract
Recent literature suggests that tri-exponential models may provide additional information and fit liver intravoxel incoherent motion (IVIM) data more accurately than conventional bi-exponential models. However, voxel-wise fitting of IVIM results in noisy and unreliable parameter maps. For bi-exponential IVIM, neural networks (NN) were able to produce superior parameter maps than conventional least-squares (LSQ) generated images. Hence, to improve parameter map quality of tri-exponential IVIM, we developed an unsupervised physics-informed deep neural network (IVIM3-NET). We assessed its performance in simulations and in patients with non-alcoholic fatty liver disease (NAFLD) and compared outcomes with bi-exponential LSQ and NN fits and tri-exponential LSQ fits. Scanning was performed using a 3.0T free-breathing multi-slice diffusion-weighted single-shot echo-planar imaging sequence with 18 b-values. Images were analysed for visual quality, comparing the bi- and tri-exponential IVIM models for LSQ fits and NN fits using parameter-map signal-to-noise ratios (SNR) and adjusted R2. IVIM parameters were compared to histological fibrosis, disease activity and steatosis grades. Parameter map quality improved with bi- and tri-exponential NN approaches, with a significant increase in average parameter-map SNR from 3.38 to 5.59 and 2.45 to 4.01 for bi- and tri-exponential LSQ and NN models respectively. In 33 out of 36 patients, the tri-exponential model exhibited higher adjusted R2 values than the bi-exponential model. Correlating IVIM data to liver histology showed that the bi- and tri-exponential NN outperformed both LSQ models for the majority of IVIM parameters (10 out of 15 significant correlations). Overall, our results support the use of a tri-exponential IVIM model in NAFLD. We show that the IVIM3-NET can be used to improve image quality compared to a tri-exponential LSQ fit and provides promising correlations with histopathology similar to the bi-exponential neural network fit, while generating potentially complementary additional parameters.
Collapse
Affiliation(s)
- Marian A. Troelstra
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, Netherlands
- *Correspondence: Marian A. Troelstra,
| | | | - Julia J. Witjes
- Department of Vascular Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Anne Linde Mak
- Department of Vascular Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Diona Zwirs
- Department of Vascular Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Jurgen H. Runge
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | - Joanne Verheij
- Department of Pathology, Amsterdam UMC, Amsterdam, Netherlands
| | - Ulrich H. Beuers
- Department of Gastroenterology and Hepatology, Amsterdam UMC, Amsterdam, Netherlands
| | - Max Nieuwdorp
- Department of Vascular Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | | | - Aart J. Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, Netherlands
| | | |
Collapse
|
24
|
Wu J, Kang T, Lan X, Chen X, Wu Z, Wang J, Lin L, Cai C, Lin J, Ding X, Cai S. IMPULSED model based cytological feature estimation with U-Net: Application to human brain tumor at 3T. Magn Reson Med 2022; 89:411-422. [PMID: 36063493 DOI: 10.1002/mrm.29429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Revised: 07/06/2022] [Accepted: 08/08/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE This work introduces and validates a deep-learning-based fitting method, which can rapidly provide accurate and robust estimation of cytological features of brain tumor based on the IMPULSED (imaging microstructural parameters using limited spectrally edited diffusion) model fitting with diffusion-weighted MRI data. METHODS The U-Net was applied to rapidly quantify extracellular diffusion coefficient (Dex ), cell size (d), and intracellular volume fraction (vin ) of brain tumor. At the training stage, the image-based training data, synthesized by randomizing quantifiable microstructural parameters within specific ranges, was used to train U-Net. At the test stage, the pre-trained U-Net was applied to estimate the microstructural parameters from simulated data and the in vivo data acquired on patients at 3T. The U-Net was compared with conventional non-linear least-squares (NLLS) fitting in simulations in terms of estimation accuracy and precision. RESULTS Our results confirm that the proposed method yields better fidelity in simulations and is more robust to noise than the NLLS fitting. For in vivo data, the U-Net yields obvious quality improvement in parameter maps, and the estimations of all parameters are in good agreement with the NLLS fitting. Moreover, our method is several orders of magnitude faster than the NLLS fitting (from about 5 min to <1 s). CONCLUSION The image-based training scheme proposed herein helps to improve the quality of the estimated parameters. Our deep-learning-based fitting method can estimate the cell microstructural parameters fast and accurately.
Collapse
Affiliation(s)
- Jian Wu
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Taishan Kang
- Department of Radiology, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| | - Xinli Lan
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Xinran Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Zhigang Wu
- MSC Clinical & Technical Solutions, Philips Healthcare, Beijing, China
| | - Jiazheng Wang
- MSC Clinical & Technical Solutions, Philips Healthcare, Beijing, China
| | - Liangjie Lin
- MSC Clinical & Technical Solutions, Philips Healthcare, Beijing, China
| | - Congbo Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Jianzhong Lin
- Department of Radiology, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| | - Xin Ding
- Department of Pathology, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| |
Collapse
|
25
|
Stabilization of parameter estimates from multiexponential decay through extension into higher dimensions. Sci Rep 2022; 12:5773. [PMID: 35388008 PMCID: PMC8986819 DOI: 10.1038/s41598-022-08638-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 03/07/2022] [Indexed: 11/23/2022] Open
Abstract
Analysis of multiexponential decay has remained a topic of active research for over 200 years. This attests to the widespread importance of this problem and to the profound difficulties in characterizing the underlying monoexponential decays. Here, we demonstrate the fundamental improvement in stability and conditioning of this classic problem through extension to a second dimension; we present statistical analysis, Monte-Carlo simulations, and experimental magnetic resonance relaxometry data to support this remarkable fact. Our results are readily generalizable to higher dimensions and provide a potential means of circumventing conventional limits on multiexponential parameter estimation.
Collapse
|
26
|
Zibetti MVW, Sharafi A, Regatte RR. Optimization of spin-lock times in T 1ρ mapping of knee cartilage: Cramér-Rao bounds versus matched sampling-fitting. Magn Reson Med 2022; 87:1418-1434. [PMID: 34738252 PMCID: PMC8822470 DOI: 10.1002/mrm.29063] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 10/12/2021] [Accepted: 10/13/2021] [Indexed: 01/03/2023]
Abstract
PURPOSE To compare different optimization approaches for choosing the spin-lock times (TSLs), in spin-lattice relaxation time in the rotating frame (T1ρ ) mapping. METHODS Optimization criteria for TSLs based on Cramér-Rao lower bounds (CRLB) are compared with matched sampling-fitting (MSF) approaches for T1ρ mapping on synthetic data, model phantoms, and knee cartilage. The MSF approaches are optimized using robust methods for noisy cost functions. The MSF approaches assume that optimal TSLs depend on the chosen fitting method. An iterative non-linear least squares (NLS) and artificial neural networks (ANN) are tested as two possible T1ρ fitting methods for MSF approaches. RESULTS All optimized criteria were better than non-optimized ones. However, we observe that a modified CRLB and an MSF based on the mean of the normalized absolute error (MNAE) were more robust optimization approaches, performing well in all tested cases. The optimized TSLs obtained the best performance with synthetic data (3.5-8.0% error), model phantoms (1.5-2.8% error), and healthy volunteers (7.7-21.1% error), showing stable and improved quality results, comparing to non-optimized approaches (4.2-13.3% error on synthetic data, 2.1-6.2% error on model phantoms, 9.8-27.8% error on healthy volunteers). CONCLUSION A modified CRLB and the MSF based on MNAE are robust optimization approaches for choosing TSLs in T1ρ mapping. All optimized criteria allowed good results even using rapid scans with two TSLs when a complex-valued fitting is done with iterative NLS or ANN.
Collapse
Affiliation(s)
- Marcelo V W Zibetti
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA
| | - Azadeh Sharafi
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA
| | - Ravinder R Regatte
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY, USA
| |
Collapse
|
27
|
Vasylechko SD, Warfield SK, Afacan O, Kurugol S. Self-supervised IVIM DWI parameter estimation with a physics based forward model. Magn Reson Med 2022; 87:904-914. [PMID: 34687065 PMCID: PMC8627432 DOI: 10.1002/mrm.28989] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 07/29/2021] [Accepted: 08/08/2021] [Indexed: 02/03/2023]
Abstract
PURPOSE To assess the robustness and repeatability of intravoxel incoherent motion model (IVIM) parameter estimation for the diffusion-weighted MRI in the abdominal organs under the constraints of noisy diffusion signal using a novel neural network method. METHODS Clinically acquired abdominal scans of Crohn's disease patients were retrospectively analyzed with regions segmented in the kidney cortex, spleen, liver, and bowel. A novel IVIM parameter fitting method based on the principle of a physics guided self-supervised convolutional neural network that does not require reference parameter estimates for training was compared to a conventional non-linear least squares (NNLS) algorithm, and a voxelwise trained artificial neural network (ANN). RESULTS Results showed substantial increase in parameter robustness to the noise corrupted signal. In an intra-session repeatability experiment, the proposed method showed reduced coefficient of variation (CoV) over multiple acquisitions in comparison to conventional NLLS method and comparable performance to ANN. The use of D and f estimates from the proposed method led to the smallest misclassification error in linear discriminant analysis for characterization between normal and abnormal Crohn's disease bowel tissue. The fitting of D∗ parameter remains to be challenging. CONCLUSION The proposed method yields robust estimates of D and f IVIM parameters under the constraints of noisy diffusion signal. This indicates a potential for the use of the proposed method in conjunction with accelerated DW-MRI acquisition strategies, which would typically result in lower signal to noise ratio.
Collapse
Affiliation(s)
- Serge Didenko Vasylechko
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
- Corresponding author: Name Serge Didenko Vasylechko, Department Computational Radiology Laboratory, Institute Boston Children’s Hospital, Address 360 Longwood Avenue, Boston, MA, 02215, USA,
| | - Simon K. Warfield
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Onur Afacan
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Sila Kurugol
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| |
Collapse
|
28
|
Zhou X, Wang X, Liu E, Zhang L, Zhang H, Zhang X, Zhu Y, Kuai Z. An Unsupervised Deep Learning Approach for
Dynamic‐Exponential
Intravoxel Incoherent Motion
MRI
Modeling and Parameter Estimation in the Liver. J Magn Reson Imaging 2022; 56:848-859. [PMID: 35064945 DOI: 10.1002/jmri.28074] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 01/09/2022] [Accepted: 01/10/2022] [Indexed: 12/18/2022] Open
Affiliation(s)
- Xin‐Xiang Zhou
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Xin‐Yu Wang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - En‐Hui Liu
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Lan Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Hong‐Xia Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Xiu‐Shi Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Yue‐Min Zhu
- CREATIS CNRS UMR 5220‐INSERM U1206‐University Lyon 1‐INSA Lyon‐University Jean Monnet Saint‐Etienne Lyon France
| | - Zi‐Xiang Kuai
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| |
Collapse
|
29
|
de Almeida Martins JP, Nilsson M, Lampinen B, Palombo M, While PT, Westin CF, Szczepankiewicz F. Neural networks for parameter estimation in microstructural MRI: Application to a diffusion-relaxation model of white matter. Neuroimage 2021; 244:118601. [PMID: 34562578 PMCID: PMC9651573 DOI: 10.1016/j.neuroimage.2021.118601] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 08/26/2021] [Accepted: 09/18/2021] [Indexed: 12/14/2022] Open
Abstract
Specific features of white matter microstructure can be investigated by using biophysical models to interpret relaxation-diffusion MRI brain data. Although more intricate models have the potential to reveal more details of the tissue, they also incur time-consuming parameter estimation that may converge to inaccurate solutions due to a prevalence of local minima in a degenerate fitting landscape. Machine-learning fitting algorithms have been proposed to accelerate the parameter estimation and increase the robustness of the attained estimates. So far, learning-based fitting approaches have been restricted to microstructural models with a reduced number of independent model parameters where dense sets of training data are easy to generate. Moreover, the degree to which machine learning can alleviate the degeneracy problem is poorly understood. For conventional least-squares solvers, it has been shown that degeneracy can be avoided by acquisition with optimized relaxation-diffusion-correlation protocols that include tensor-valued diffusion encoding. Whether machine-learning techniques can offset these acquisition requirements remains to be tested. In this work, we employ artificial neural networks to vastly accelerate the parameter estimation for a recently introduced relaxation-diffusion model of white matter microstructure. We also develop strategies for assessing the accuracy and sensitivity of function fitting networks and use those strategies to explore the impact of the acquisition protocol. The developed learning-based fitting pipelines were tested on relaxation-diffusion data acquired with optimal and sub-optimal acquisition protocols. Networks trained with an optimized protocol were observed to provide accurate parameter estimates within short computational times. Comparing neural networks and least-squares solvers, we found the performance of the former to be less affected by sub-optimal protocols; however, model fitting networks were still susceptible to degeneracy issues and their use could not fully replace a careful design of the acquisition protocol.
Collapse
Affiliation(s)
- João P de Almeida Martins
- Department of Clinical Sciences, Radiology, Lund University, Lund, Sweden; Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway.
| | - Markus Nilsson
- Department of Clinical Sciences, Radiology, Lund University, Lund, Sweden
| | - Björn Lampinen
- Department of Clinical Sciences, Medical Radiation Physics, Lund University, Lund, Sweden
| | - Marco Palombo
- Centre for Medical Image Computing and Department of Computer Science, University College London, London, United Kingdom
| | - Peter T While
- Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway; Department of Circulation and Medical Imaging, NTNU-Norwegian University of Science and Technology, Trondheim, Norway
| | - Carl-Fredrik Westin
- Radiology, Brigham and Women's Hospital, Boston, MA, United States; Harvard Medical School, Boston, MA, United States
| | - Filip Szczepankiewicz
- Department of Clinical Sciences, Radiology, Lund University, Lund, Sweden; Radiology, Brigham and Women's Hospital, Boston, MA, United States; Harvard Medical School, Boston, MA, United States
| |
Collapse
|
30
|
Kaandorp MPT, Barbieri S, Klaassen R, van Laarhoven HWM, Crezee H, While PT, Nederveen AJ, Gurney‐Champion OJ. Improved unsupervised physics-informed deep learning for intravoxel incoherent motion modeling and evaluation in pancreatic cancer patients. Magn Reson Med 2021; 86:2250-2265. [PMID: 34105184 PMCID: PMC8362093 DOI: 10.1002/mrm.28852] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 04/30/2021] [Accepted: 05/03/2021] [Indexed: 12/12/2022]
Abstract
PURPOSE Earlier work showed that IVIM-NETorig , an unsupervised physics-informed deep neural network, was faster and more accurate than other state-of-the-art intravoxel-incoherent motion (IVIM) fitting approaches to diffusion-weighted imaging (DWI). This study presents a substantially improved version, IVIM-NEToptim , and characterizes its superior performance in pancreatic cancer patients. METHOD In simulations (signal-to-noise ratio [SNR] = 20), the accuracy, independence, and consistency of IVIM-NET were evaluated for combinations of hyperparameters (fit S0, constraints, network architecture, number of hidden layers, dropout, batch normalization, learning rate), by calculating the normalized root-mean-square error (NRMSE), Spearman's ρ, and the coefficient of variation (CVNET ), respectively. The best performing network, IVIM-NEToptim was compared to least squares (LS) and a Bayesian approach at different SNRs. IVIM-NEToptim 's performance was evaluated in an independent dataset of 23 patients with pancreatic ductal adenocarcinoma. Fourteen of the patients received no treatment between two repeated scan sessions and nine received chemoradiotherapy between the repeated sessions. Intersession within-subject standard deviations (wSD) and treatment-induced changes were assessed. RESULTS In simulations (SNR = 20), IVIM-NEToptim outperformed IVIM-NETorig in accuracy (NRMSE(D) = 0.177 vs 0.196; NMRSE(f) = 0.220 vs 0.267; NMRSE(D*) = 0.386 vs 0.393), independence (ρ(D*, f) = 0.22 vs 0.74), and consistency (CVNET (D) = 0.013 vs 0.104; CVNET (f) = 0.020 vs 0.054; CVNET (D*) = 0.036 vs 0.110). IVIM-NEToptim showed superior performance to the LS and Bayesian approaches at SNRs < 50. In vivo, IVIM-NEToptim showed significantly less noisy parameter maps with lower wSD for D and f than the alternatives. In the treated cohort, IVIM-NEToptim detected the most individual patients with significant parameter changes compared to day-to-day variations. CONCLUSION IVIM-NEToptim is recommended for accurate, informative, and consistent IVIM fitting to DWI data.
Collapse
Affiliation(s)
- Misha P. T. Kaandorp
- Department of Radiology and Nuclear MedicineCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
- Department of Radiology and Nuclear MedicineSt. Olav’s University HospitalTrondheimNorway
- Department of Circulation and Medical ImagingNTNU – Norwegian University of Science and TechnologyTrondheimNorway
| | | | - Remy Klaassen
- Department of Medical OncologyCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Hanneke W. M. van Laarhoven
- Department of Medical OncologyCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Hans Crezee
- Department of Radiology and Nuclear MedicineCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Peter T. While
- Department of Radiology and Nuclear MedicineSt. Olav’s University HospitalTrondheimNorway
- Department of Circulation and Medical ImagingNTNU – Norwegian University of Science and TechnologyTrondheimNorway
| | - Aart J. Nederveen
- Department of Radiology and Nuclear MedicineCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Oliver J. Gurney‐Champion
- Department of Radiology and Nuclear MedicineCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| |
Collapse
|
31
|
Chevallier O, Wáng YXJ, Guillen K, Pellegrinelli J, Cercueil JP, Loffroy R. Evidence of Tri-Exponential Decay for Liver Intravoxel Incoherent Motion MRI: A Review of Published Results and Limitations. Diagnostics (Basel) 2021; 11:diagnostics11020379. [PMID: 33672277 PMCID: PMC7926368 DOI: 10.3390/diagnostics11020379] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 02/14/2021] [Accepted: 02/20/2021] [Indexed: 12/11/2022] Open
Abstract
Diffusion weighted imaging (DWI) and intravoxel incoherent motion (IVIM) have been explored to assess liver tumors and diffused liver diseases. IVIM reflects the microscopic translational motions that occur in voxels in magnetic resonance (MR) DWI. In biologic tissues, molecular diffusion of water and microcirculation of blood in the capillary network can be assessed using IVIM DWI. The most commonly applied model to describe the DWI signal is a bi-exponential model, with a slow compartment of diffusion linked to pure molecular diffusion (represented by the coefficient Dslow), and a fast compartment of diffusion, related to microperfusion (represented by the coefficient Dfast). However, high variance in Dfast estimates has been consistently shown in literature for liver IVIM, restricting its application in clinical practice. This variation could be explained by the presence of another very fast compartment of diffusion in the liver. Therefore, a tri-exponential model would be more suitable to describe the DWI signal. This article reviews the published evidence of the existence of this additional very fast diffusion compartment and discusses the performance and limitations of the tri-exponential model for liver IVIM in current clinical settings.
Collapse
Affiliation(s)
- Olivier Chevallier
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
| | - Yì Xiáng J. Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, New Territories, Hong Kong, China;
| | - Kévin Guillen
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
| | - Julie Pellegrinelli
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
| | - Jean-Pierre Cercueil
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
| | - Romaric Loffroy
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
- Correspondence: ; Tel.: +33-380-293-677
| |
Collapse
|
32
|
Liao YP, Urayama SI, Isa T, Fukuyama H. Optimal Model Mapping for Intravoxel Incoherent Motion MRI. Front Hum Neurosci 2021; 15:617152. [PMID: 33692677 PMCID: PMC7937866 DOI: 10.3389/fnhum.2021.617152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 01/11/2021] [Indexed: 11/30/2022] Open
Abstract
In general, only one diffusion model would be applied to whole field-of-view voxels in the intravoxel incoherent motion-magnetic resonance imaging (IVIM-MRI) study. However, the choice of the applied diffusion model can significantly influence the estimated diffusion parameters. The quality of the diffusion analysis can influence the reliability of the perfusion analysis. This study proposed an optimal model mapping method to improve the reliability of the perfusion parameter estimation in the IVIM study. Six healthy volunteers (five males and one female; average age of 38.3 ± 7.5 years). Volunteers were examined using a 3.0 Tesla scanner. IVIM-MRI of the brain was applied at 17 b-values ranging from 0 to 2,500 s/mm2. The Gaussian model, the Kurtosis model, and the Gamma model were found to be optimal for the CSF, white matter (WM), and gray matter (GM), respectively. In the mean perfusion fraction (fp) analysis, the GM/WM ratios were 1.16 (Gaussian model), 1.80 (Kurtosis model), 1.94 (Gamma model), and 1.54 (Optimal model mapping); in the mean pseudo diffusion coefficient (D*) analysis, the GM/WM ratios were 1.18 (Gaussian model), 1.19 (Kurtosis model), 1.56 (Gamma model), and 1.24 (Optimal model mapping). With the optimal model mapping method, the estimated fp and D* were reliable compared with the conventional methods. In addition, the optimal model maps, the associated products of this method, may provide additional information for clinical diagnosis.
Collapse
Affiliation(s)
- Yen-Peng Liao
- Division of Neurobiology and Physiology, Department of Neuroscience, Graduate School of Medicine in Kyoto University, Kyoto, Japan.,Human Brain Research Center, Graduate School of Medicine in Kyoto University, Kyoto, Japan
| | - Shin-Ichi Urayama
- Division of Neurobiology and Physiology, Department of Neuroscience, Graduate School of Medicine in Kyoto University, Kyoto, Japan.,Human Brain Research Center, Graduate School of Medicine in Kyoto University, Kyoto, Japan
| | - Tadashi Isa
- Division of Neurobiology and Physiology, Department of Neuroscience, Graduate School of Medicine in Kyoto University, Kyoto, Japan.,Human Brain Research Center, Graduate School of Medicine in Kyoto University, Kyoto, Japan.,Faculty of Medicine, Institute for the Advanced Study of Human Biology (ASHBi), Kyoto University, Kyoto, Japan
| | - Hidenao Fukuyama
- Human Brain Research Center, Graduate School of Medicine in Kyoto University, Kyoto, Japan.,Department of Rehabilitation Medicine, Graduate School of Medicine, Nagoya City University, Nagoya, Japan
| |
Collapse
|
33
|
Lee W, Kim B, Park H. Quantification of intravoxel incoherent motion with optimized b-values using deep neural network. Magn Reson Med 2021; 86:230-244. [PMID: 33594783 DOI: 10.1002/mrm.28708] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 01/12/2021] [Accepted: 01/13/2021] [Indexed: 12/17/2022]
Abstract
PURPOSE To develop a framework for quantifying intravoxel incoherent motion (IVIM) parameters, where a neural network for quantification and b-values for diffusion-weighted imaging are simultaneously optimized. METHOD A deep neural network (DNN) method is proposed for accurate quantification of IVIM parameters from multiple diffusion-weighted images. In addition, optimal b-values are selected to acquire the multiple diffusion-weighted images. The proposed framework consists of an MRI signal generation part and an IVIM parameter quantification part. Monte-Carlo (MC) simulations were performed to evaluate the accuracy of the IVIM parameter quantification and the efficacy of b-value optimization. In order to analyze the effect of noise on the optimized b-values, simulations were performed with five different noise levels. For in vivo data, diffusion images were acquired with the b-values from four b-values selection methods for five healthy volunteers at 3T MRI system. RESULTS Experiment results showed that both the optimization of b-values and the training of DNN were simultaneously performed to quantify IVIM parameters. We found that the accuracies of the perfusion coefficient (Dp ) and perfusion fraction (f) were more sensitive to b-values than the diffusion coefficient (D) was. Furthermore, when the noise level changed, the optimized b-values also changed. Therefore, noise level has to be considered when optimizing b-values for IVIM quantification. CONCLUSION The proposed scheme can simultaneously optimize b-values and train DNN to minimize quantification errors of IVIM parameters. The trained DNN can quantify IVIM parameters from the diffusion-weighted images obtained with the optimized b-values.
Collapse
Affiliation(s)
- Wonil Lee
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Byungjai Kim
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - HyunWook Park
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| |
Collapse
|
34
|
Jelescu IO, Palombo M, Bagnato F, Schilling KG. Challenges for biophysical modeling of microstructure. J Neurosci Methods 2020; 344:108861. [PMID: 32692999 PMCID: PMC10163379 DOI: 10.1016/j.jneumeth.2020.108861] [Citation(s) in RCA: 67] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/10/2020] [Accepted: 07/14/2020] [Indexed: 02/07/2023]
Abstract
The biophysical modeling efforts in diffusion MRI have grown considerably over the past 25 years. In this review, we dwell on the various challenges along the journey of bringing a biophysical model from initial design to clinical implementation, identifying both hurdles that have been already overcome and outstanding issues. First, we describe the critical initial task of selecting which features of tissue microstructure can be estimated using a model and which acquisition protocol needs to be implemented to make the estimation possible. The model performance should necessarily be tested in realistic numerical simulations and in experimental data - adapting the fitting strategy accordingly, and parameter estimates should be validated against complementary techniques, when/if available. Secondly, the model performance and validity should be explored in pathological conditions, and, if appropriate, dedicated models for pathology should be developed. We build on examples from tumors, ischemia and demyelinating diseases. We then discuss the challenges associated with clinical translation and added value. Finally, we single out four major unresolved challenges that are related to: the availability of a microstructural ground truth, the validation of model parameters which cannot be accessed with complementary techniques, the development of a generalized standard model for any brain region and pathology, and the seamless communication between different parties involved in the development and application of biophysical models of diffusion.
Collapse
|
35
|
Ye C, Xu D, Qin Y, Wang L, Wang R, Li W, Kuai Z, Zhu Y. Accurate intravoxel incoherent motion parameter estimation using Bayesian fitting and reduced number of low b-values. Med Phys 2020; 47:4372-4385. [PMID: 32403175 DOI: 10.1002/mp.14233] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 03/02/2020] [Accepted: 04/15/2020] [Indexed: 12/28/2022] Open
Abstract
PURPOSE Intravoxel incoherent motion (IVIM) magnetic resonance imaging is a potential noninvasive technique for the diagnosis of brain tumors. However, perfusion-related parameter mapping is a persistent problem. The purpose of this paper is to investigate the IVIM parameter mapping of brain tumors using Bayesian fitting and low b-values. METHODS Bayesian shrinkage prior (BSP) fitting method and different low b-value distributions were used to estimate IVIM parameters (diffusion D, pseudo-diffusion D*, and perfusion fraction F). The results were compared to those obtained by least squares (LSQ) on both simulated and in vivo brain data. Relative error (RE) and reproducibility were used to evaluate the results. The differences of IVIM parameters between brain tumor and normal regions were compared and used to assess the performance of Bayesian fitting in the IVIM application of brain tumor. RESULTS In tumor regions, the value of D* tended to be decreased when the number of low b-values was insufficient, especially with LSQ. BSP required less low b-values than LSQ for the correct estimation of perfusion parameters of brain tumors. The IVIM parameter maps of brain tumors yielded by BSP had smaller variability, lower RE, and higher reproducibility with respect to those obtained by LSQ. Obvious differences were observed between tumor and normal regions in parameters D (P < 0.05) and F (P < 0.001), especially F. BSP generated fewer outliers than LSQ, and distinguished better tumors from normal regions in parameter F. CONCLUSIONS Intravoxel incoherent motion parameters clearly allow brain tumors to be differentiated from normal regions. Bayesian fitting yields robust IVIM parameter mapping with fewer outliers and requires less low b-values than LSQ for the parameter estimation.
Collapse
Affiliation(s)
- Chen Ye
- Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, School of Computer Science and Technology, Guizhou University, Guiyang, China
| | - Daoyun Xu
- Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, School of Computer Science and Technology, Guizhou University, Guiyang, China
| | - Yongbin Qin
- Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, School of Computer Science and Technology, Guizhou University, Guiyang, China
| | - Lihui Wang
- Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, School of Computer Science and Technology, Guizhou University, Guiyang, China
| | - Rongpin Wang
- Department of Radiology, Guizhou Provincial People's Hospital, Guiyang, China
| | - Wuchao Li
- Department of Radiology, Guizhou Provincial People's Hospital, Guiyang, China
| | - Zixiang Kuai
- Harbin Medical University Cancer Hospital, Harbin, China
| | - Yuemin Zhu
- Univ Lyon, INSA Lyon, CNRS, INSERM, CREATIS UMR 5220, U1206, Lyon, F-69621, France
| |
Collapse
|
36
|
Jung S, Lee H, Ryu K, Song JE, Park M, Moon WJ, Kim DH. Artificial neural network for multi-echo gradient echo-based myelin water fraction estimation. Magn Reson Med 2020; 85:380-389. [PMID: 32686208 DOI: 10.1002/mrm.28407] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 06/09/2020] [Accepted: 06/09/2020] [Indexed: 02/01/2023]
Abstract
PURPOSE To demonstrate robust myelin water fraction (MWF) mapping using an artificial neural network (ANN) with multi-echo gradient-echo (GRE) signal. METHODS Multi-echo gradient-echo signals simulated with a three-pool exponential model were used to generate the training data set for the ANN, which was designed to yield the MWF. We investigated the performance of our proposed ANN for various conditions using both numerical simulations and in vivo data. Simulations were conducted with various SNRs to investigate the performance of the ANN. In vivo data with high spatial resolutions were applied in the analyses, and results were compared with MWFs derived by the nonlinear least-squares algorithm using a complex three-pool exponential model. RESULTS The network results for the simulations show high accuracies against noise compared with nonlinear least-squares MWFs: RMS-error value of 5.46 for the nonlinear least-squares MWF and 3.56 for the ANN MWF at an SNR of 150 (relative gain = 34.80%). These effects were also found in the in vivo data, with reduced SDs in the region-of-interest analyses. These effects of the ANN demonstrate the feasibility of acquiring high-resolution myelin water images. CONCLUSION The simulation results and in vivo data suggest that the ANN facilitates more robust MWF mapping in multi-echo gradient-echo sequences compared with the conventional nonlinear least-squares method.
Collapse
Affiliation(s)
- Soozy Jung
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Hongpyo Lee
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Kanghyun Ryu
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Jae Eun Song
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| | - Mina Park
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Won-Jin Moon
- Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Republic of Korea
| | - Dong-Hyun Kim
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
37
|
Iima M. Perfusion-driven Intravoxel Incoherent Motion (IVIM) MRI in Oncology: Applications, Challenges, and Future Trends. Magn Reson Med Sci 2020; 20:125-138. [PMID: 32536681 PMCID: PMC8203481 DOI: 10.2463/mrms.rev.2019-0124] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Recent developments in MR hardware and software have allowed a surge of interest in intravoxel incoherent motion (IVIM) MRI in oncology. Beyond diffusion-weighted imaging (and the standard apparent diffusion coefficient mapping most commonly used clinically), IVIM provides information on tissue microcirculation without the need for contrast agents. In oncology, perfusion-driven IVIM MRI has already shown its potential for the differential diagnosis of malignant and benign tumors, as well as for detecting prognostic biomarkers and treatment monitoring. Current developments in IVIM data processing, and its use as a method of scanning patients who cannot receive contrast agents, are expected to increase further utilization. This paper reviews the current applications, challenges, and future trends of perfusion-driven IVIM in oncology.
Collapse
Affiliation(s)
- Mami Iima
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine.,Department of Clinical Innovative Medicine, Institute for Advancement of Clinical and Translational Science (iACT), Kyoto University Hospital
| |
Collapse
|
38
|
Exploring linearity of deep neural network trained QSM: QSMnet+. Neuroimage 2020; 211:116619. [DOI: 10.1016/j.neuroimage.2020.116619] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 01/08/2020] [Accepted: 02/05/2020] [Indexed: 01/24/2023] Open
|
39
|
Gurney‐Champion OJ, Rauh SS, Harrington K, Oelfke U, Laun FB, Wetscherek A. Optimal acquisition scheme for flow-compensated intravoxel incoherent motion diffusion-weighted imaging in the abdomen: An accurate and precise clinically feasible protocol. Magn Reson Med 2020; 83:1003-1015. [PMID: 31566262 PMCID: PMC6899942 DOI: 10.1002/mrm.27990] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 08/14/2019] [Accepted: 08/17/2019] [Indexed: 12/16/2022]
Abstract
PURPOSE Flow-compensated (FC) diffusion-weighted MRI (DWI) for intravoxel-incoherent motion (IVIM) modeling allows for a more detailed description of tissue microvasculature than conventional IVIM. The long acquisition time of current FC-IVIM protocols, however, has prohibited clinical application. Therefore, we developed an optimized abdominal FC-IVIM acquisition with a clinically feasible scan time. METHODS Precision and accuracy of the FC-IVIM parameters were assessed by fitting the FC-IVIM model to signal decay curves, simulated for different acquisition schemes. Diffusion-weighted acquisitions were added subsequently to the protocol, where we chose the combination of b-value, diffusion time and gradient profile (FC or bipolar) that resulted in the largest improvement to its accuracy and precision. The resulting two optimized FC-IVIM protocols with 25 and 50 acquisitions (FC-IVIMopt25 and FC-IVIMopt50 ), together with a complementary acquisition consisting of 50 diffusion-weighting (FC-IVIMcomp ), were acquired in repeated abdominal free-breathing FC-IVIM imaging of seven healthy volunteers. Intersession and intrasession within-subject coefficient of variation of the FC-IVIM parameters were compared for the liver, spleen, and kidneys. RESULTS Simulations showed that the performance of FC-IVIM improved in tissue with larger perfusion fraction and signal-to-noise ratio. The scan time of the FC-IVIMopt25 and FC-IVIMopt50 protocols were 8 and 16 min. The best in vivo performance was seen in FC-IVIMopt50 . The intersession within-subject coefficients of variation of FC-IVIMopt50 were 11.6%, 16.3%, 65.5%, and 36.0% for FC-IVIM model parameters diffusivity, perfusion fraction, characteristic time and blood flow velocity, respectively. CONCLUSIONS We have optimized the FC-IVIM protocol, allowing for clinically feasible scan times (8-16 min).
Collapse
Affiliation(s)
- Oliver J. Gurney‐Champion
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Susanne S. Rauh
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
- Institute of RadiologyUniversity Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU)ErlangenGermany
| | - Kevin Harrington
- Targeted Therapy teamThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Uwe Oelfke
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Frederik B. Laun
- Institute of RadiologyUniversity Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU)ErlangenGermany
| | - Andreas Wetscherek
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| |
Collapse
|
40
|
Lévy S, Rapacchi S, Massire A, Troalen T, Feiweier T, Guye M, Callot V. Intravoxel Incoherent Motion at 7 Tesla to quantify human spinal cord perfusion: limitations and promises. Magn Reson Med 2020; 84:1198-1217. [DOI: 10.1002/mrm.28195] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 12/16/2019] [Accepted: 01/10/2020] [Indexed: 12/15/2022]
Affiliation(s)
- Simon Lévy
- Aix‐Marseille Univ, CNRS, CRMBM Marseille France
- APHM, Hopital Universitaire Timone, CEMEREM Marseille France
- Aix‐Marseille Univ, IFSTTAR, LBA Marseille France
- iLab‐Spine International Associated Laboratory Marseille‐Montreal France‐Canada
| | - Stanislas Rapacchi
- Aix‐Marseille Univ, CNRS, CRMBM Marseille France
- APHM, Hopital Universitaire Timone, CEMEREM Marseille France
| | - Aurélien Massire
- Aix‐Marseille Univ, CNRS, CRMBM Marseille France
- APHM, Hopital Universitaire Timone, CEMEREM Marseille France
- iLab‐Spine International Associated Laboratory Marseille‐Montreal France‐Canada
| | | | | | - Maxime Guye
- Aix‐Marseille Univ, CNRS, CRMBM Marseille France
- APHM, Hopital Universitaire Timone, CEMEREM Marseille France
| | - Virginie Callot
- Aix‐Marseille Univ, CNRS, CRMBM Marseille France
- APHM, Hopital Universitaire Timone, CEMEREM Marseille France
- iLab‐Spine International Associated Laboratory Marseille‐Montreal France‐Canada
| |
Collapse
|
41
|
Glang F, Deshmane A, Prokudin S, Martin F, Herz K, Lindig T, Bender B, Scheffler K, Zaiss M. DeepCEST 3T: Robust MRI parameter determination and uncertainty quantification with neural networks—application to CEST imaging of the human brain at 3T. Magn Reson Med 2019; 84:450-466. [DOI: 10.1002/mrm.28117] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 10/23/2019] [Accepted: 11/18/2019] [Indexed: 01/07/2023]
Affiliation(s)
- Felix Glang
- Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Anagha Deshmane
- Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Sergey Prokudin
- Department of Perceiving Systems Max Planck Institute for Intelligent Systems Tübingen Germany
| | - Florian Martin
- Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Kai Herz
- Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tübingen Germany
| | - Tobias Lindig
- Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tübingen Germany
- Department of Diagnostic and Interventional Neuroradiology Eberhard Karls University Tübingen Tübingen Germany
| | - Benjamin Bender
- Department of Diagnostic and Interventional Neuroradiology Eberhard Karls University Tübingen Tübingen Germany
| | - Klaus Scheffler
- Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tübingen Germany
- Department of Biomedical Magnetic Resonance Eberhard Karls University Tübingen Tübingen Germany
| | - Moritz Zaiss
- Magnetic Resonance Center Max Planck Institute for Biological Cybernetics Tübingen Germany
- Department of Neuroradiology University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU) Erlangen Germany
| |
Collapse
|
42
|
Barbieri S, Gurney‐Champion OJ, Klaassen R, Thoeny HC. Deep learning how to fit an intravoxel incoherent motion model to diffusion‐weighted MRI. Magn Reson Med 2019; 83:312-321. [DOI: 10.1002/mrm.27910] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Revised: 06/22/2019] [Accepted: 06/26/2019] [Indexed: 12/29/2022]
Affiliation(s)
| | - Oliver J. Gurney‐Champion
- Joint Department of Physics The Institute of Cancer Research London United Kingdom
- The Royal Marsden NHS Foundation Trust London United Kingdom
| | - Remy Klaassen
- Cancer Center Amsterdam, Department of Medical Oncology and LEXOR (Laboratory for Experimental Oncology and Radiobiology) Academic Medical Center Amsterdam The Netherlands
| | - Harriet C. Thoeny
- Department of Radiology HFR Fribourg‐Hôpital Cantonal Fribourg Switzerland
| |
Collapse
|
43
|
Hubertus S, Thomas S, Cho J, Zhang S, Wang Y, Schad LR. Using an artificial neural network for fast mapping of the oxygen extraction fraction with combined QSM and quantitative BOLD. Magn Reson Med 2019; 82:2199-2211. [PMID: 31273828 DOI: 10.1002/mrm.27882] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 05/28/2019] [Accepted: 06/05/2019] [Indexed: 12/11/2022]
Abstract
PURPOSE To apply an artificial neural network (ANN) for fast and robust quantification of the oxygen extraction fraction (OEF) from a combined QSM and quantitative BOLD analysis of gradient echo data and to compare the ANN to a traditional quasi-Newton (QN) method for numerical optimization. METHODS Random combinations of OEF, deoxygenated blood volume ( ν ), R2 , and nonblood magnetic susceptibility ( χ nb ) with each parameter following a Gaussian distribution that represented physiological gray matter and white matter values were used to simulate quantitative BOLD signals and QSM values. An ANN was trained with the simulated data with added Gaussian noise. The ANN was applied to multigradient echo brain data of 7 healthy subjects, and the reconstructed parameters and maps were compared to QN results using Student t test and Bland-Altman analysis. RESULTS Intersubject means and SDs of gray matter were OEF = 43.5 ± 0.8 %, R 2 = 13.5 ± 0.3 Hz, ν = 3.4 ± 0.1 %, χ nb = - 25 ± 5 ppb for ANN; and OEF = 43.8 ± 5.2 %, R 2 = 12.2 ± 0.8 Hz, ν = 4.2 ± 0.6 %, χ nb = - 39 ± 7 ppb for QN, with a significant difference ( P < 0.05 ) for R 2 , ν , and χ nb . For white matter, they were OEF = 47.5 ± 1.1 %, R 2 = 17.1 ± 0.4 Hz, ν = 2.5 ± 0.2 %, χ nb = - 38 ± 5 ppb for ANN; and OEF = 42.3 ± 5.6 %, R 2 = 16.7 ± 0.7 Hz, ν = 2.9 ± 0.3 %, χ nb = - 45 ± 9 ppb for QN, with a significant difference ( P < 0.05 ) for OEF and ν . ANN revealed more gray-white matter contrast but less intersubject variation in OEF than QN. In contrast to QN, the ANN reconstruction did not need an additional sequence for parameter initialization and took approximately 1 s rather than roughly 1 h. CONCLUSION ANNs allow faster and, with regard to initialization, more robust reconstruction of OEF maps with lower intersubject variation than QN approaches.
Collapse
Affiliation(s)
- Simon Hubertus
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Sebastian Thomas
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Junghun Cho
- Department of Biomedical Engineering, Cornell University, Ithaca, New York
| | - Shun Zhang
- Department of Radiology, Weill Cornell Medical College, New York, New York.,Department of Radiology, Tongji Hospital, Wuhan, China
| | - Yi Wang
- Department of Biomedical Engineering, Cornell University, Ithaca, New York.,Department of Radiology, Weill Cornell Medical College, New York, New York
| | - Lothar Rudi Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|
44
|
Ravi D, Ghavami N, Alexander DC, Ianus A. Current Applications and Future Promises of Machine Learning in Diffusion MRI. COMPUTATIONAL DIFFUSION MRI 2019. [DOI: 10.1007/978-3-030-05831-9_9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
45
|
Affiliation(s)
- Doohee Lee
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Institute of Engineering Research, Seoul National University, Seoul, Korea
| | - Jingu Lee
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Institute of Engineering Research, Seoul National University, Seoul, Korea
| | - Jingyu Ko
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Institute of Engineering Research, Seoul National University, Seoul, Korea
| | - Jaeyeon Yoon
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Institute of Engineering Research, Seoul National University, Seoul, Korea
| | - Kanghyun Ryu
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
| | - Yoonho Nam
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| |
Collapse
|
46
|
Paschoal AM, Leoni RF, Dos Santos AC, Paiva FF. Intravoxel incoherent motion MRI in neurological and cerebrovascular diseases. Neuroimage Clin 2018; 20:705-714. [PMID: 30221622 PMCID: PMC6141267 DOI: 10.1016/j.nicl.2018.08.030] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 08/27/2018] [Accepted: 08/30/2018] [Indexed: 12/20/2022]
Abstract
Intravoxel Incoherent Motion (IVIM) is a recently rediscovered noninvasive magnetic resonance imaging (MRI) method based on diffusion-weighted imaging. It enables the separation of the intravoxel signal into diffusion due to Brownian motion and perfusion-related contributions and provides important information on microperfusion in the tissue and therefore it is a promising tool for applications in neurological and neurovascular diseases. This review focuses on the basic principles and outputs of IVIM and details it major applications in the brain, such as stroke, tumor, and cerebral small vessel disease. A bi-exponential model that considers two different compartments, namely capillaries, and medium-sized vessels, has been frequently used for the description of the IVIM signal and may be important in those clinical applications cited before. Moreover, the combination of IVIM and arterial spin labeling MRI enables the estimation of water permeability across the blood-brain barrier (BBB), suggesting a potential imaging biomarker for disrupted-BBB diseases.
Collapse
Affiliation(s)
- André M Paschoal
- Inbrain Lab, Department de Física, FFCLRP, Universidade de São Paulo, São Carlos, SP, Brazil
| | - Renata F Leoni
- Inbrain Lab, Department de Física, FFCLRP, Universidade de São Paulo, São Carlos, SP, Brazil
| | - Antonio C Dos Santos
- Departamento de Clínica Médica, FMRP, Universidade de São Paulo, São Carlos, SP, Brazil
| | - Fernando F Paiva
- Instituto de Física de São Carlos, Universidade de São Paulo, São Carlos, SP, Brazil.
| |
Collapse
|
47
|
Ertas G. Estimating the distributed diffusion coefficient of breast tissue in diffusion-weighted imaging using multilayer perceptrons. Soft comput 2018. [DOI: 10.1007/s00500-018-3412-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|