1
|
Liao C, Cao X, Iyer SS, Schauman S, Zhou Z, Yan X, Chen Q, Li Z, Wang N, Gong T, Wu Z, He H, Zhong J, Yang Y, Kerr A, Grill-Spector K, Setsompop K. High-resolution myelin-water fraction and quantitative relaxation mapping using 3D ViSTa-MR fingerprinting. Magn Reson Med 2024; 91:2278-2293. [PMID: 38156945 PMCID: PMC10997479 DOI: 10.1002/mrm.29990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 12/11/2023] [Accepted: 12/11/2023] [Indexed: 01/03/2024]
Abstract
PURPOSE This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous mapping of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time. METHODS We developed 3D visualization of short transverse relaxation time component (ViSTa)-MRF, which combined ViSTa technique with MR fingerprinting (MRF), to achieve high-fidelity whole-brain MWF and T1/T2/PD mapping on a clinical 3T scanner. To achieve fast acquisition and memory-efficient reconstruction, the ViSTa-MRF sequence leverages an optimized 3D tiny-golden-angle-shuffling spiral-projection acquisition and joint spatial-temporal subspace reconstruction with optimized preconditioning algorithm. With the proposed ViSTa-MRF approach, high-fidelity direct MWF mapping was achieved without a need for multicompartment fitting that could introduce bias and/or noise from additional assumptions or priors. RESULTS The in vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide fast multi-parametric mapping with high SNR and good quality. The in vivo results of 1 mm- and 0.66 mm-isotropic resolution datasets indicate that the MWF values measured by the proposed method are consistent with standard ViSTa results that are 30× slower with lower SNR. Furthermore, we applied the proposed method to enable 5-min whole-brain 1 mm-iso assessment of MWF and T1/T2/PD mappings for infant brain development and for post-mortem brain samples. CONCLUSIONS In this work, we have developed a 3D ViSTa-MRF technique that enables the acquisition of whole-brain MWF, quantitative T1, T2, and PD maps at 1 and 0.66 mm isotropic resolution in 5 and 15 min, respectively. This advancement allows for quantitative investigations of myelination changes in the brain.
Collapse
Affiliation(s)
- Congyu Liao
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Xiaozhi Cao
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Siddharth Srinivasan Iyer
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Sophie Schauman
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Zihan Zhou
- Department of Radiology, Stanford University, Stanford, CA, USA
- Center for Brain Imaging Science and Technology, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Xiaoqian Yan
- Department of Psychology, Stanford University, Stanford, CA, USA
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China
| | - Quan Chen
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Zhitao Li
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Nan Wang
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| | - Ting Gong
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Zhe Wu
- Techna Institute, University Health Network, Toronto, ON, Canada
| | - Hongjian He
- Center for Brain Imaging Science and Technology, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
- School of Physics, Zhejiang University, Hangzhou, Zhejiang, China
| | - Jianhui Zhong
- Center for Brain Imaging Science and Technology, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
- Department of Imaging Sciences, University of Rochester, Rochester, NY, USA
| | - Yang Yang
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Adam Kerr
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
- Stanford Center for Cognitive and Neurobiological Imaging, Stanford University, Stanford, CA, USA
| | | | - Kawin Setsompop
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Electrical Engineering, Stanford University, Stanford, CA, USA
| |
Collapse
|
2
|
Jun Y, Arefeen Y, Cho J, Fujita S, Wang X, Ellen Grant P, Gagoski B, Jaimes C, Gee MS, Bilgic B. Zero-DeepSub: Zero-shot deep subspace reconstruction for rapid multiparametric quantitative MRI using 3D-QALAS. Magn Reson Med 2024; 91:2459-2482. [PMID: 38282270 PMCID: PMC11005062 DOI: 10.1002/mrm.30018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 12/15/2023] [Accepted: 01/06/2024] [Indexed: 01/30/2024]
Abstract
PURPOSE To develop and evaluate methods for (1) reconstructing 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) time-series images using a low-rank subspace method, which enables accurate and rapid T1 and T2 mapping, and (2) improving the fidelity of subspace QALAS by combining scan-specific deep-learning-based reconstruction and subspace modeling. THEORY AND METHODS A low-rank subspace method for 3D-QALAS (i.e., subspace QALAS) and zero-shot deep-learning subspace method (i.e., Zero-DeepSub) were proposed for rapid and high fidelity T1 and T2 mapping and time-resolved imaging using 3D-QALAS. Using an ISMRM/NIST system phantom, the accuracy and reproducibility of the T1 and T2 maps estimated using the proposed methods were evaluated by comparing them with reference techniques. The reconstruction performance of the proposed subspace QALAS using Zero-DeepSub was evaluated in vivo and compared with conventional QALAS at high reduction factors of up to nine-fold. RESULTS Phantom experiments showed that subspace QALAS had good linearity with respect to the reference methods while reducing biases and improving precision compared to conventional QALAS, especially for T2 maps. Moreover, in vivo results demonstrated that subspace QALAS had better g-factor maps and could reduce voxel blurring, noise, and artifacts compared to conventional QALAS and showed robust performance at up to nine-fold acceleration with Zero-DeepSub, which enabled whole-brain T1, T2, and PD mapping at 1 mm isotropic resolution within 2 min of scan time. CONCLUSION The proposed subspace QALAS along with Zero-DeepSub enabled high fidelity and rapid whole-brain multiparametric quantification and time-resolved imaging.
Collapse
Affiliation(s)
- Yohan Jun
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Yamin Arefeen
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas, Austin, TX, United States
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Jaejin Cho
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Shohei Fujita
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - Xiaoqing Wang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
| | - P. Ellen Grant
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children’s Hospital, Boston, MA, United States
| | - Borjan Gagoski
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children’s Hospital, Boston, MA, United States
| | - Camilo Jaimes
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
| | - Michael S. Gee
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States
- Department of Radiology, Harvard Medical School, Boston, MA, United States
- Harvard/MIT Health Sciences and Technology, Cambridge, MA, United States
| |
Collapse
|
3
|
Ma D, Badve C, Sun JEP, Hu S, Wang X, Chen Y, Nayate A, Wien M, Martin D, Singer LT, Durieux JC, Flask C, Costello DW. Motion Robust MR Fingerprinting Scan to Image Neonates With Prenatal Opioid Exposure. J Magn Reson Imaging 2024; 59:1758-1768. [PMID: 37515516 PMCID: PMC10823040 DOI: 10.1002/jmri.28907] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 07/04/2023] [Accepted: 07/05/2023] [Indexed: 07/31/2023] Open
Abstract
PURPOSE To explore whether MR fingerprinting (MRF) scans provide motion-robust and quantitative brain tissue measurements for non-sedated infants with prenatal opioid exposure (POE). STUDY TYPE Prospective. POPULATION 13 infants with POE (3 male; 12 newborns (age 7-65 days) and 1 infant aged 9-months). FIELD STRENGTH/SEQUENCE 3T, 3D T1-weighted MPRAGE, 3D T2-weighted TSE and MRF sequences. ASSESSMENT The image quality of MRF and MRI was assessed in a fully crossed, multiple-reader, multiple-case study. Sixteen image quality features in three types-image artifacts, structure and myelination visualization-were ranked by four neuroradiologists (8, 7, 5, and 8 years of experience respectively), using a 3-point scale. MRF T1 and T2 values in 8 white matter brain regions were compared between babies younger than 1 month and babies between 1 and 2 months. STATISTICAL TESTS Generalized estimating equations model to test the significance of differences of regional T1 and T2 values of babies under 1 month and those older. MRI and MRF image quality was assessed using Gwet's second order auto-correlation coefficient (AC2) with confidence levels. The Cochran-Mantel-Haenszel test was used to assess the difference in proportions between MRF and MRI for all features and stratified by the type of features. A P value <0.05 was considered statistically significant. RESULTS The MRF of two infants were excluded in T1 and T2 value analysis due to severe motion artifact but were included in the image quality assessment. In infants under 1 month of age (N = 6), the T1 and T2 values were significantly higher compared to those between 1 and 2 months of age (N = 4). MRF images showed significantly higher image quality ratings in all three feature types compared to MRI images. CONCLUSIONS MR Fingerprinting scans have potential to be a motion-robust and efficient method for nonsedated infants. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Dan Ma
- Biomedical Engineering, Case Western Reserve University, Cleveland, OH
| | - Chaitra Badve
- Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH
| | - Jessie EP Sun
- Radiology, Case Western Reserve University, Cleveland, OH
| | - Siyuan Hu
- Biomedical Engineering, Case Western Reserve University, Cleveland, OH
| | - Xiaofeng Wang
- Quantitative Health Science, Cleveland Clinic, Cleveland, OH
| | - Yong Chen
- Radiology, Case Western Reserve University, Cleveland, OH
| | - Ameya Nayate
- Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH
| | - Michael Wien
- Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH
| | - Douglas Martin
- Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH
| | - Lynn T Singer
- Population and Quantitative Health Sciences, Case Western Reserve University, Cleveland
| | - Jared C. Durieux
- Radiology, University Hospitals Cleveland Medical Center, Cleveland, OH
| | - Chris Flask
- Radiology, Case Western Reserve University, Cleveland, OH
| | | |
Collapse
|
4
|
Slioussarenko C, Baudin PY, Reyngoudt H, Marty B. Bi-component dictionary matching for MR fingerprinting for efficient quantification of fat fraction and water T 1 in skeletal muscle. Magn Reson Med 2024; 91:1179-1189. [PMID: 37867467 DOI: 10.1002/mrm.29901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 09/15/2023] [Accepted: 10/06/2023] [Indexed: 10/24/2023]
Abstract
PURPOSE To propose an efficient bi-component MR fingerprinting (MRF) fitting method using a Variable Projection (VARPRO) strategy, applied to the quantification of fat fraction (FF) and water T1 (T 1 H 2 0 $$ \mathrm{T}{1}_{{\mathrm{H}}_20} $$ ) in skeletal muscle tissues. METHODS The MRF signals were analyzed in a two-step process by comparing them to the elements of separate water and fat dictionaries (bi-component dictionary matching). First, each pair of water and fat dictionary elements was fitted to the acquired signal to determine an optimal FF that was used to merge the fingerprints in a combined water/fat dictionary. Second, standard dictionary matching was applied to the combined dictionary for determining the remaining parameters. A clustering method was implemented to further accelerate the fitting. Accuracy, precision, and matching time of this approach were evaluated on both numerical and in vivo datasets, and compared to the reference dictionary-matching approach that includes FF as a dictionary parameter. RESULTS In numerical phantoms, all MRF parameters showed high correlation with ground truth for the reference and the bi-component method (R2 > 0.98). In vivo, the estimated parameters from the proposed method were highly correlated with those from the reference approach (R2 > 0.997). The bi-component method achieved an acceleration factor of up to 360 compared to the reference dictionary matching. CONCLUSION The proposed bi-component fitting approach enables a significant acceleration of the reconstruction of MRF parameter maps for fat-water imaging, while maintaining comparable precision and accuracy to the reference on FF andT 1 H 2 0 $$ \mathrm{T}{1}_{{\mathrm{H}}_20} $$ estimation.
Collapse
Affiliation(s)
| | - Pierre-Yves Baudin
- Institute of Myology, Neuromuscular Investigation Center, NMR Laboratory, Paris, France
| | - Harmen Reyngoudt
- Institute of Myology, Neuromuscular Investigation Center, NMR Laboratory, Paris, France
| | - Benjamin Marty
- Institute of Myology, Neuromuscular Investigation Center, NMR Laboratory, Paris, France
| |
Collapse
|
5
|
Monga A, Singh D, de Moura HL, Zhang X, Zibetti MVW, Regatte RR. Emerging Trends in Magnetic Resonance Fingerprinting for Quantitative Biomedical Imaging Applications: A Review. Bioengineering (Basel) 2024; 11:236. [PMID: 38534511 DOI: 10.3390/bioengineering11030236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/21/2024] [Accepted: 02/22/2024] [Indexed: 03/28/2024] Open
Abstract
Magnetic resonance imaging (MRI) stands as a vital medical imaging technique, renowned for its ability to offer high-resolution images of the human body with remarkable soft-tissue contrast. This enables healthcare professionals to gain valuable insights into various aspects of the human body, including morphology, structural integrity, and physiological processes. Quantitative imaging provides compositional measurements of the human body, but, currently, either it takes a long scan time or is limited to low spatial resolutions. Undersampled k-space data acquisitions have significantly helped to reduce MRI scan time, while compressed sensing (CS) and deep learning (DL) reconstructions have mitigated the associated undersampling artifacts. Alternatively, magnetic resonance fingerprinting (MRF) provides an efficient and versatile framework to acquire and quantify multiple tissue properties simultaneously from a single fast MRI scan. The MRF framework involves four key aspects: (1) pulse sequence design; (2) rapid (undersampled) data acquisition; (3) encoding of tissue properties in MR signal evolutions or fingerprints; and (4) simultaneous recovery of multiple quantitative spatial maps. This paper provides an extensive literature review of the MRF framework, addressing the trends associated with these four key aspects. There are specific challenges in MRF for all ranges of magnetic field strengths and all body parts, which can present opportunities for further investigation. We aim to review the best practices in each key aspect of MRF, as well as for different applications, such as cardiac, brain, and musculoskeletal imaging, among others. A comprehensive review of these applications will enable us to assess future trends and their implications for the translation of MRF into these biomedical imaging applications.
Collapse
Affiliation(s)
- Anmol Monga
- Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Dilbag Singh
- Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Hector L de Moura
- Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Xiaoxia Zhang
- Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Marcelo V W Zibetti
- Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Ravinder R Regatte
- Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY 10016, USA
| |
Collapse
|
6
|
Wang K, Doneva M, Meineke J, Amthor T, Karasan E, Tan F, Tamir JI, Yu SX, Lustig M. High-fidelity direct contrast synthesis from magnetic resonance fingerprinting. Magn Reson Med 2023; 90:2116-2129. [PMID: 37332200 DOI: 10.1002/mrm.29766] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 05/03/2023] [Accepted: 05/31/2023] [Indexed: 06/20/2023]
Abstract
PURPOSE This work was aimed at proposing a supervised learning-based method that directly synthesizes contrast-weighted images from the Magnetic Resonance Fingerprinting (MRF) data without performing quantitative mapping and spin-dynamics simulations. METHODS To implement our direct contrast synthesis (DCS) method, we deploy a conditional generative adversarial network (GAN) framework with a multi-branch U-Net as the generator and a multilayer CNN (PatchGAN) as the discriminator. We refer to our proposed approach as N-DCSNet. The input MRF data are used to directly synthesize T1-weighted, T2-weighted, and fluid-attenuated inversion recovery (FLAIR) images through supervised training on paired MRF and target spin echo-based contrast-weighted scans. The performance of our proposed method is demonstrated on in vivo MRF scans from healthy volunteers. Quantitative metrics, including normalized root mean square error (nRMSE), peak signal-to-noise ratio (PSNR), structural similarity (SSIM), learned perceptual image patch similarity (LPIPS), and Fréchet inception distance (FID), were used to evaluate the performance of the proposed method and compare it with others. RESULTS In-vivo experiments demonstrated excellent image quality with respect to that of simulation-based contrast synthesis and previous DCS methods, both visually and according to quantitative metrics. We also demonstrate cases in which our trained model is able to mitigate the in-flow and spiral off-resonance artifacts typically seen in MRF reconstructions, and thus more faithfully represent conventional spin echo-based contrast-weighted images. CONCLUSION We present N-DCSNet to directly synthesize high-fidelity multicontrast MR images from a single MRF acquisition. This method can significantly decrease examination time. By directly training a network to generate contrast-weighted images, our method does not require any model-based simulation and therefore can avoid reconstruction errors due to dictionary matching and contrast simulation (code available at:https://github.com/mikgroup/DCSNet).
Collapse
Affiliation(s)
- Ke Wang
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California, USA
- International Computer Science Institute, University of California at Berkeley, Berkeley, California, USA
| | | | | | | | - Ekin Karasan
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California, USA
| | - Fei Tan
- Bioengineering, UC Berkeley-UCSF, San Francisco, California, USA
| | - Jonathan I Tamir
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas, USA
| | - Stella X Yu
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California, USA
- International Computer Science Institute, University of California at Berkeley, Berkeley, California, USA
- Computer Science and Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | | |
Collapse
|
7
|
Nagtegaal MA, Hermann I, Weingärtner S, Martinez-Heras E, Solana E, Llufriu S, Gass A, Poot DHJ, van Osch MJP, Vos FM, de Bresser J. White matter changes measured by multi-component MR Fingerprinting in multiple sclerosis. Neuroimage Clin 2023; 40:103528. [PMID: 37837891 PMCID: PMC10589890 DOI: 10.1016/j.nicl.2023.103528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 09/11/2023] [Accepted: 10/09/2023] [Indexed: 10/16/2023]
Abstract
T2-hyperintense lesions are the key imaging marker of multiple sclerosis (MS). Previous studies have shown that the white matter surrounding such lesions is often also affected by MS. Our aim was to develop a new method to visualize and quantify the extent of white matter tissue changes in MS based on relaxometry properties. We applied a fast, multi-parametric quantitative MRI approach and used a multi-component MR Fingerprinting (MC-MRF) analysis. We assessed the differences in the MRF component representing prolongedrelaxation time between patients with MS and controls and studied the relation between this component's volume and structural white matter damage identified on FLAIR MRI scans in patients with MS. A total of 48 MS patients at two different sites and 12 healthy controls were scanned with FLAIR and MRF-EPI MRI scans. MRF scans were analyzed with a joint-sparsity multi-component analysis to obtain magnetization fraction maps of different components, representing tissues such as myelin water, white matter, gray matter and cerebrospinal fluid. In the MS patients, an additional component was identified with increased transverse relaxation times compared to the white matter, likely representing changes in free water content. Patients with MS had a higher volume of the long- component in the white matter of the brain compared to healthy controls (B (95%-CI) = 0.004 (0.0006-0.008), p = 0.02). Furthermore, this MRF component had a moderate correlation (correlation coefficient R 0.47) with visible structural white matter changes on the FLAIR scans. Also, the component was found to be more extensive compared to structural white matter changes in 73% of MS patients. In conclusion, our MRF acquisition and analysis captured white matter tissue changes in MS patients compared to controls. In patients these tissue changes were more extensive compared to visually detectable white matter changes on FLAIR scans. Our method provides a novel way to quantify the extent of white matter changes in MS patients, which is underestimated using only conventional clinical MRI scans.
Collapse
Affiliation(s)
- Martijn A Nagtegaal
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands; C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.
| | - Ingo Hermann
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands; Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - Eloy Martinez-Heras
- Neuroimmunology and Multiple Sclerosis Unit and Laboratory of Advanced Imaging in Neuroimmunological Diseases (ImaginEM). Hospital Clinic Barcelona, Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Elisabeth Solana
- Neuroimmunology and Multiple Sclerosis Unit and Laboratory of Advanced Imaging in Neuroimmunological Diseases (ImaginEM). Hospital Clinic Barcelona, Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Sara Llufriu
- Neuroimmunology and Multiple Sclerosis Unit and Laboratory of Advanced Imaging in Neuroimmunological Diseases (ImaginEM). Hospital Clinic Barcelona, Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Achim Gass
- Department of Neurology, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Dirk H J Poot
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands
| | - Matthias J P van Osch
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Frans M Vos
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands; Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands
| | - Jeroen de Bresser
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
8
|
Sheagren CD, Cao T, Patel JH, Chen Z, Lee HL, Wang N, Christodoulou AG, Wright GA. Motion-compensated T 1 mapping in cardiovascular magnetic resonance imaging: a technical review. Front Cardiovasc Med 2023; 10:1160183. [PMID: 37790594 PMCID: PMC10542904 DOI: 10.3389/fcvm.2023.1160183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 08/22/2023] [Indexed: 10/05/2023] Open
Abstract
T 1 mapping is becoming a staple magnetic resonance imaging method for diagnosing myocardial diseases such as ischemic cardiomyopathy, hypertrophic cardiomyopathy, myocarditis, and more. Clinically, most T 1 mapping sequences acquire a single slice at a single cardiac phase across a 10 to 15-heartbeat breath-hold, with one to three slices acquired in total. This leaves opportunities for improving patient comfort and information density by acquiring data across multiple cardiac phases in free-running acquisitions and across multiple respiratory phases in free-breathing acquisitions. Scanning in the presence of cardiac and respiratory motion requires more complex motion characterization and compensation. Most clinical mapping sequences use 2D single-slice acquisitions; however newer techniques allow for motion-compensated reconstructions in three dimensions and beyond. To further address confounding factors and improve measurement accuracy, T 1 maps can be acquired jointly with other quantitative parameters such as T 2 , T 2 ∗ , fat fraction, and more. These multiparametric acquisitions allow for constrained reconstruction approaches that isolate contributions to T 1 from other motion and relaxation mechanisms. In this review, we examine the state of the literature in motion-corrected and motion-resolved T 1 mapping, with potential future directions for further technical development and clinical translation.
Collapse
Affiliation(s)
- Calder D. Sheagren
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Tianle Cao
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States
- Department of Bioengineering, University of California, Los Angeles, CA, United States
| | - Jaykumar H. Patel
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Zihao Chen
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States
- Department of Bioengineering, University of California, Los Angeles, CA, United States
| | - Hsu-Lei Lee
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States
| | - Nan Wang
- Department of Radiology, Stanford University, Stanford, CA, United States
| | - Anthony G. Christodoulou
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States
- Department of Bioengineering, University of California, Los Angeles, CA, United States
| | - Graham A. Wright
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| |
Collapse
|
9
|
Gaur S, Panda A, Fajardo JE, Hamilton J, Jiang Y, Gulani V. Magnetic Resonance Fingerprinting: A Review of Clinical Applications. Invest Radiol 2023; 58:561-577. [PMID: 37026802 PMCID: PMC10330487 DOI: 10.1097/rli.0000000000000975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
Abstract
ABSTRACT Magnetic resonance fingerprinting (MRF) is an approach to quantitative magnetic resonance imaging that allows for efficient simultaneous measurements of multiple tissue properties, which are then used to create accurate and reproducible quantitative maps of these properties. As the technique has gained popularity, the extent of preclinical and clinical applications has vastly increased. The goal of this review is to provide an overview of currently investigated preclinical and clinical applications of MRF, as well as future directions. Topics covered include MRF in neuroimaging, neurovascular, prostate, liver, kidney, breast, abdominal quantitative imaging, cardiac, and musculoskeletal applications.
Collapse
Affiliation(s)
- Sonia Gaur
- Department of Radiology, Michigan Medicine, Ann Arbor, MI
| | - Ananya Panda
- All India Institute of Medical Sciences, Jodhpur, Rajasthan, India
| | | | - Jesse Hamilton
- Department of Radiology, Michigan Medicine, Ann Arbor, MI
| | - Yun Jiang
- Department of Radiology, Michigan Medicine, Ann Arbor, MI
| | - Vikas Gulani
- Department of Radiology, Michigan Medicine, Ann Arbor, MI
| |
Collapse
|
10
|
Fotaki A, Velasco C, Prieto C, Botnar RM. Quantitative MRI in cardiometabolic disease: From conventional cardiac and liver tissue mapping techniques to multi-parametric approaches. Front Cardiovasc Med 2023; 9:991383. [PMID: 36756640 PMCID: PMC9899858 DOI: 10.3389/fcvm.2022.991383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 12/29/2022] [Indexed: 01/24/2023] Open
Abstract
Cardiometabolic disease refers to the spectrum of chronic conditions that include diabetes, hypertension, atheromatosis, non-alcoholic fatty liver disease, and their long-term impact on cardiovascular health. Histological studies have confirmed several modifications at the tissue level in cardiometabolic disease. Recently, quantitative MR methods have enabled non-invasive myocardial and liver tissue characterization. MR relaxation mapping techniques such as T1, T1ρ, T2 and T2* provide a pixel-by-pixel representation of the corresponding tissue specific relaxation times, which have been shown to correlate with fibrosis, altered tissue perfusion, oedema and iron levels. Proton density fat fraction mapping approaches allow measurement of lipid tissue in the organ of interest. Several studies have demonstrated their utility as early diagnostic biomarkers and their potential to bear prognostic implications. Conventionally, the quantification of these parameters by MRI relies on the acquisition of sequential scans, encoding and mapping only one parameter per scan. However, this methodology is time inefficient and suffers from the confounding effects of the relaxation parameters in each single map, limiting wider clinical and research applications. To address these limitations, several novel approaches have been proposed that encode multiple tissue parameters simultaneously, providing co-registered multiparametric information of the tissues of interest. This review aims to describe the multi-faceted myocardial and hepatic tissue alterations in cardiometabolic disease and to motivate the application of relaxometry and proton-density cardiac and liver tissue mapping techniques. Current approaches in myocardial and liver tissue characterization as well as latest technical developments in multiparametric quantitative MRI are included. Limitations and challenges of these novel approaches, and recommendations to facilitate clinical validation are also discussed.
Collapse
Affiliation(s)
- Anastasia Fotaki
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom,*Correspondence: Anastasia Fotaki,
| | - Carlos Velasco
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom,School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile,Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile,Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile
| | - René M. Botnar
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom,School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile,Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile,Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile
| |
Collapse
|
11
|
Afzali M, Mueller L, Sakaie K, Hu S, Chen Y, Szczepankiewicz F, Griswold MA, Jones DK, Ma D. MR Fingerprinting with b-Tensor Encoding for Simultaneous Quantification of Relaxation and Diffusion in a Single Scan. Magn Reson Med 2022; 88:2043-2057. [PMID: 35713357 PMCID: PMC9420788 DOI: 10.1002/mrm.29352] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 05/19/2022] [Accepted: 05/20/2022] [Indexed: 11/08/2022]
Abstract
PURPOSE Although both relaxation and diffusion imaging are sensitive to tissue microstructure, studies have reported limited sensitivity and robustness of using relaxation or conventional diffusion alone to characterize tissue microstructure. Recently, it has been shown that tensor-valued diffusion encoding and joint relaxation-diffusion quantification enable more reliable quantification of compartment-specific microstructural properties. However, scan times to acquire such data can be prohibitive. Here, we aim to simultaneously quantify relaxation and diffusion using MR fingerprinting (MRF) and b-tensor encoding in a clinically feasible time. METHODS We developed multidimensional MRF scans (mdMRF) with linear and spherical b-tensor encoding (LTE and STE) to simultaneously quantify T1, T2, and ADC maps from a single scan. The image quality, accuracy, and scan efficiency were compared between the mdMRF using LTE and STE. Moreover, we investigated the robustness of different sequence designs to signal errors and their impact on the maps. RESULTS T1 and T2 maps derived from the mdMRF scans have consistently high image quality, while ADC maps are sensitive to different sequence designs. Notably, the fast imaging steady state precession (FISP)-based mdMRF scan with peripheral pulse gating provides the best ADC maps that are free of image distortion and shading artifacts. CONCLUSION We demonstrated the feasibility of quantifying T1, T2, and ADC maps simultaneously from a single mdMRF scan in around 24 s/slice. The map quality and quantitative values are consistent with the reference scans.
Collapse
Affiliation(s)
- Maryam Afzali
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of Leeds
LeedsUK
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff UniversityCardiffUK
| | - Lars Mueller
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of Leeds
LeedsUK
| | - Ken Sakaie
- Imaging Institute, Cleveland ClinicClevelandOhioUSA
| | - Siyuan Hu
- Biomedical EngineeringCase Western Reserve UniversityClevelandOhioUSA
| | - Yong Chen
- RadiologyCase Western Reserve UniversityClevelandOhioUSA
| | | | | | - Derek K. Jones
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff UniversityCardiffUK
| | - Dan Ma
- Biomedical EngineeringCase Western Reserve UniversityClevelandOhioUSA
| |
Collapse
|
12
|
Nunez-Gonzalez L, Nagtegaal MA, Poot DHJ, de Bresser J, van Osch MJP, Hernandez-Tamames JA, Vos FM. Accuracy and repeatability of joint sparsity multi-component estimation in MR Fingerprinting. Neuroimage 2022; 263:119638. [PMID: 36122685 DOI: 10.1016/j.neuroimage.2022.119638] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 08/11/2022] [Accepted: 08/31/2022] [Indexed: 11/30/2022] Open
Abstract
MR fingerprinting (MRF) is a promising method for quantitative characterization of tissues. Often, voxel-wise measurements are made, assuming a single tissue-type per voxel. Alternatively, the Sparsity Promoting Iterative Joint Non-negative least squares Multi-Component MRF method (SPIJN-MRF) facilitates tissue parameter estimation for identified components as well as partial volume segmentations. The aim of this paper was to evaluate the accuracy and repeatability of the SPIJN-MRF parameter estimations and partial volume segmentations. This was done (1) through numerical simulations based on the BrainWeb phantoms and (2) using in vivo acquired MRF data from 5 subjects that were scanned on the same week-day for 8 consecutive weeks. The partial volume segmentations of the SPIJN-MRF method were compared to those obtained by two conventional methods: SPM12 and FSL. SPIJN-MRF showed higher accuracy in simulations in comparison to FSL- and SPM12-based segmentations: Fuzzy Tanimoto Coefficients (FTC) comparing these segmentations and Brainweb references were higher than 0.95 for SPIJN-MRF in all the tissues and between 0.6 and 0.7 for SPM12 and FSL in white and gray matter and between 0.5 and 0.6 in CSF. For the in vivo MRF data, the estimated relaxation times were in line with literature and minimal variation was observed. Furthermore, the coefficient of variation (CoV) for estimated tissue volumes with SPIJN-MRF were 10.5% for the myelin water, 6.0% for the white matter, 5.6% for the gray matter, 4.6% for the CSF and 1.1% for the total brain volume. CoVs for CSF and total brain volume measured on the scanned data for SPIJN-MRF were in line with those obtained with SPM12 and FSL. The CoVs for white and gray matter volumes were distinctively higher for SPIJN-MRF than those measured with SPM12 and FSL. In conclusion, the use of SPIJN-MRF provides accurate and precise tissue relaxation parameter estimations taking into account intrinsic partial volume effects. It facilitates obtaining tissue fraction maps of prevalent tissues including myelin water which can be relevant for evaluating diseases affecting the white matter.
Collapse
Affiliation(s)
- L Nunez-Gonzalez
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands.
| | - M A Nagtegaal
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - D H J Poot
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands
| | - J de Bresser
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - M J P van Osch
- C.J. Gorter Center for MRI, Radiology Department, Leiden University Medical Center, Leiden, the Netherlands
| | - J A Hernandez-Tamames
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands; Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - F M Vos
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, the Netherlands; Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| |
Collapse
|
13
|
Lo WC, Panda A, Jiang Y, Ahad J, Gulani V, Seiberlich N. MR fingerprinting of the prostate. MAGMA (NEW YORK, N.Y.) 2022; 35:557-571. [PMID: 35419668 DOI: 10.1007/s10334-022-01012-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 03/21/2022] [Accepted: 03/24/2022] [Indexed: 06/03/2023]
Abstract
Multiparametric magnetic resonance imaging (mpMRI) has been adopted as the key tool for detection, localization, characterization, and risk stratification of patients suspected to have prostate cancer. Despite advantages over systematic biopsy, the interpretation of prostate mpMRI has limitations including a steep learning curve, leading to considerable interobserver variation. There is growing interest in clinical translation of quantitative imaging techniques for more objective lesion assessment. However, traditional mapping techniques are slow, precluding their use in the clinic. Magnetic resonance fingerprinting (MRF) is an efficient approach for quantitative maps of multiple tissue properties simultaneously. The T1 and T2 values obtained with MRF have been validated with phantom studies as well as in normal volunteers and patients. Studies have shown that MRF-derived T1 and T2 along with ADC values are all significant independent predictors in the differentiation between normal prostate tissue and prostate cancer, and hold promise in differentiating low and intermediate/high-grade cancers. This review seeks to introduce the basics of the prostate MRF technique, discuss the potential applications of prostate MRF for the characterization of prostate cancer, and describes ongoing areas of research.
Collapse
Affiliation(s)
- Wei-Ching Lo
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
- Siemens Medical Solutions USA, Boston, Massachusetts, USA
| | - Ananya Panda
- Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, MN, 55905, USA
| | - Yun Jiang
- Department of Radiology, University of Michigan, University of Michigan Health System, 1500 E. Medical Center Drive, Ann Arbor, MI, 48109-5030, USA
| | - James Ahad
- Case Western Reserve University, Cleveland, OH, USA
| | - Vikas Gulani
- Department of Radiology, University of Michigan, University of Michigan Health System, 1500 E. Medical Center Drive, Ann Arbor, MI, 48109-5030, USA
| | - Nicole Seiberlich
- Department of Radiology, University of Michigan, University of Michigan Health System, 1500 E. Medical Center Drive, Ann Arbor, MI, 48109-5030, USA.
- Case Western Reserve University, Cleveland, OH, USA.
| |
Collapse
|
14
|
Abstract
Magnetic resonance fingerprinting (MRF) is increasingly being used to evaluate brain development and differentiate normal and pathologic tissues in children. MRF can provide reliable and accurate intrinsic tissue properties, such as T1 and T2 relaxation times. MRF is a powerful tool in evaluating brain disease in pediatric population. MRF is a new quantitative MR imaging technique for rapid and simultaneous quantification of multiple tissue properties.
Collapse
Affiliation(s)
- Sheng-Che Hung
- Department of Radiology, School of Medicine, University of North Carolina at Chapel Hill, 2006 Old Clinic, CB#7510, 101 Manning Dr, Chapel Hill, NC 27599, USA; Biomedical Research Imaging Center, School of Medicine, University of North Carolina at Chapel Hill, 125 Mason Farm Road, Marsico Hall, suite 1200, Chapel Hill, NC 27599, USA
| | - Yong Chen
- Department of Radiology, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA
| | - Pew-Thian Yap
- Department of Radiology, School of Medicine, University of North Carolina at Chapel Hill, 2006 Old Clinic, CB#7510, 101 Manning Dr, Chapel Hill, NC 27599, USA; Biomedical Research Imaging Center, School of Medicine, University of North Carolina at Chapel Hill, 125 Mason Farm Road, Marsico Hall, suite 1200, Chapel Hill, NC 27599, USA
| | - Weili Lin
- Department of Radiology, School of Medicine, University of North Carolina at Chapel Hill, 2006 Old Clinic, CB#7510, 101 Manning Dr, Chapel Hill, NC 27599, USA; Biomedical Research Imaging Center, School of Medicine, University of North Carolina at Chapel Hill, 125 Mason Farm Road, Marsico Hall, suite 1200, Chapel Hill, NC 27599, USA.
| |
Collapse
|
15
|
Chen Y, Lu L, Zhu T, Ma D. Technical overview of magnetic resonance fingerprinting and its applications in radiation therapy. Med Phys 2021; 49:2846-2860. [PMID: 34633687 DOI: 10.1002/mp.15254] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 08/23/2021] [Accepted: 09/17/2021] [Indexed: 11/07/2022] Open
Abstract
Magnetic resonance fingerprinting (MRF) is an emerging imaging technique for rapid and simultaneous quantification of multiple tissue properties. The technique has been developed for quantitative imaging of different organs. The obtained quantitative measures have the potential to improve multiple steps of a typical radiotherapy workflow and potentially further improve integration of magnetic resonance imaging guided clinical decision making. In this review paper, we first provide a technical overview of the MRF method from data acquisition to postprocessing, along with recent development in advanced reconstruction methods. We further discuss critical aspects that could influence its usage in radiation therapy, such as accuracy and precision, repeatability and reproducibility, geometric distortion, and motion robustness. Finally, future directions for MRF application in radiation therapy are discussed.
Collapse
Affiliation(s)
- Yong Chen
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Lan Lu
- Radiation Oncology, Cleveland Clinic, Cleveland, Ohio, USA
| | - Tong Zhu
- Radiation Oncology, Washington University in St Louis, St Louis, Missouri, USA
| | - Dan Ma
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
16
|
Khajehim M, Christen T, Tam F, Graham SJ. Streamlined magnetic resonance fingerprinting: Fast whole-brain coverage with deep-learning based parameter estimation. Neuroimage 2021; 238:118237. [PMID: 34091035 DOI: 10.1016/j.neuroimage.2021.118237] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 05/26/2021] [Accepted: 06/02/2021] [Indexed: 01/02/2023] Open
Abstract
Magnetic resonance fingerprinting (MRF) is a quantitative MRI (qMRI) framework that provides simultaneous estimates of multiple relaxation parameters as well as metrics of field inhomogeneity in a single acquisition. However, current challenges exist in the forms of (1) scan time; (2) need for custom image reconstruction; (3) large dictionary sizes; (4) long dictionary-matching time. This study aims to introduce a novel streamlined magnetic-resonance fingerprinting (sMRF) framework based on a single-shot echo-planar imaging (EPI) sequence to simultaneously estimate tissue T1, T2, and T2* with integrated B1+ correction. Encouraged by recent work on EPI-based MRF, we developed a method that combines spin-echo EPI with gradient-echo EPI to achieve T2 in addition to T1 and T2* quantification. To this design, we add simultaneous multi-slice (SMS) acceleration to enable full-brain coverage in a few minutes. Moreover, in the parameter-estimation step, we use deep learning to train a deep neural network (DNN) to accelerate the estimation process by orders of magnitude. Notably, due to the high image quality of the EPI scans, the training process can rely simply on Bloch-simulated data. The DNN also removes the need for storing large dictionaries. Phantom scans along with in-vivo multi-slice scans from seven healthy volunteers were acquired with resolutions of 1.1×1.1×3 mm3 and 1.7×1.7×3 mm3, and the results were validated against ground truth measurements. Excellent correspondence was found between our T1, T2, and T2* estimates and results obtained from standard approaches. In the phantom scan, a strong linear relationship (R = 1-1.04, R2>0.96) was found for all parameter estimates, with a particularly high agreement for T2 estimation (R2>0.99). Similar findings are reported for the in-vivo human data for all of our parameter estimates. Incorporation of DNN results in a reduction of parameter estimation time on the order of 1000 x and a reduction in storage requirements on the order of 2500 x while achieving highly similar results as conventional dictionary matching (%differences of 7.4 ± 0.4%, 3.6 ± 0.3% and 6.0 ± 0.4% error in T1, T2, and T2* estimation). Thus, sMRF has the potential to be the method of choice for future MRF studies by providing ease of implementation, fast whole-brain coverage, and ultra-fast T1/T2/T2* estimation.
Collapse
Affiliation(s)
- Mahdi Khajehim
- Department of Medical Biophysics, University of Toronto, 101 College St Suite 15-701, Toronto, ON M5G 1L7, Canada.
| | - Thomas Christen
- Grenoble Institute of Neuroscience, Inserm, Grenoble, France
| | - Fred Tam
- Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Simon J Graham
- Department of Medical Biophysics, University of Toronto, 101 College St Suite 15-701, Toronto, ON M5G 1L7, Canada; Hurvitz Brain Sciences Research Program, Sunnybrook Research Institute, Toronto, ON, Canada
| |
Collapse
|
17
|
Tippareddy C, Zhao W, Sunshine JL, Griswold M, Ma D, Badve C. Magnetic resonance fingerprinting: an overview. Eur J Nucl Med Mol Imaging 2021; 48:4189-4200. [PMID: 34037831 DOI: 10.1007/s00259-021-05384-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Accepted: 04/25/2021] [Indexed: 12/17/2022]
Abstract
Magnetic resonance fingerprinting (MRF) is an evolving quantitative MRI framework consisting of unique data acquisition, processing, visualization, and interpretation steps. MRF is capable of simultaneously producing multiple high-resolution property maps including T1, T2, M0, ADC, and T2* measurements. While a relatively new technology, MRF has undergone rapid development for a variety of clinical applications from brain tumor characterization and epilepsy imaging to characterization of prostate cancer, cardiac imaging, among others. This paper will provide a brief overview of current state of MRF technology including highlights of technical and clinical advances. We will conclude with a brief discussion of the challenges that need to be overcome to establish MRF as a quantitative imaging biomarker.
Collapse
Affiliation(s)
- Charit Tippareddy
- Case Western Reserve University School of Medicine, 11100 Euclid Ave., Cleveland, OH, 44106, USA
| | - Walter Zhao
- Case Western Reserve University School of Medicine, 11100 Euclid Ave., Cleveland, OH, 44106, USA
| | - Jeffrey L Sunshine
- Department of Radiology, Case Western Reserve University and University Hospitals Cleveland Medical Center, 11100 Euclid Ave., Cleveland, OH, 44106, USA
| | - Mark Griswold
- Department of Biomedical Engineering, Case Western Reserve University, 11100 Euclid Ave., Cleveland, OH, 44106, USA.,Department of Radiology, Case Western Reserve University and University Hospitals Cleveland Medical Center, 11100 Euclid Ave., Cleveland, OH, 44106, USA
| | - Dan Ma
- Department of Biomedical Engineering, Case Western Reserve University, 11100 Euclid Ave., Cleveland, OH, 44106, USA
| | - Chaitra Badve
- Department of Radiology, Case Western Reserve University and University Hospitals Cleveland Medical Center, 11100 Euclid Ave., Cleveland, OH, 44106, USA.
| |
Collapse
|
18
|
Kiselev VG, Körzdörfer G, Gall P. Toward Quantification: Microstructure and Magnetic Resonance Fingerprinting. Invest Radiol 2021; 56:1-9. [PMID: 33186141 DOI: 10.1097/rli.0000000000000738] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Quantitative magnetic resonance imaging (MRI) is a long-standing challenge. We advocate that the origin of the problem is the simplification applied in commonly used models of the MRI signal relation to the target parameters of biological tissues. Two research fields are briefly reviewed as ways to respond to the challenge of quantitative MRI, both experiencing an exponential growth right now. Microstructure MRI strives to build physiology-based models from cells to signal and, given the signal, back to the cells again. Magnetic resonance fingerprinting aims at efficient simultaneous determination of multiple signal parameters. The synergy of these yet disjoined approaches promises truly quantitative MRI with specific target-oriented diagnostic tools rather than universal imaging methods.
Collapse
Affiliation(s)
- Valerij G Kiselev
- From the Medical Physics, Department of Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg
| | | | | |
Collapse
|
19
|
Ropella-Panagis K, Seiberlich N. Magnetic Resonance Fingerprinting: Basic Concepts and Applications in Molecular Imaging. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00067-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
20
|
Serrao EM, Kessler DA, Carmo B, Beer L, Brindle KM, Buonincontri G, Gallagher FA, Gilbert FJ, Godfrey E, Graves MJ, McLean MA, Sala E, Schulte RF, Kaggie JD. Magnetic resonance fingerprinting of the pancreas at 1.5 T and 3.0 T. Sci Rep 2020; 10:17563. [PMID: 33067515 PMCID: PMC7567885 DOI: 10.1038/s41598-020-74462-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 09/29/2020] [Indexed: 12/18/2022] Open
Abstract
Magnetic resonance imaging of the pancreas is increasingly used as an important diagnostic modality for characterisation of pancreatic lesions. Pancreatic MRI protocols are mostly qualitative due to time constraints and motion sensitivity. MR Fingerprinting is an innovative acquisition technique that provides qualitative data and quantitative parameter maps from a single free-breathing acquisition with the potential to reduce exam times. This work investigates the feasibility of MRF parameter mapping for pancreatic imaging in the presence of free-breathing exam. Sixteen healthy participants were prospectively imaged using MRF framework. Regions-of-interest were drawn in multiple solid organs including the pancreas and T1 and T2 values determined. MRF T1 and T2 mapping was performed successfully in all participants (acquisition time:2.4-3.6 min). Mean pancreatic T1 values were 37-43% lower than those of the muscle, spleen, and kidney at both 1.5 and 3.0 T. For these organs, the mean pancreatic T2 values were nearly 40% at 1.5 T and < 12% at 3.0 T. The feasibility of MRF at 1.5 T and 3 T was demonstrated in the pancreas. By enabling fast and free-breathing quantitation, MRF has the potential to add value during the clinical characterisation and grading of pathological conditions, such as pancreatitis or cancer.
Collapse
Affiliation(s)
- Eva M Serrao
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | - Dimitri A Kessler
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | - Bruno Carmo
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | - Lucian Beer
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | | | | | - Ferdia A Gallagher
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | - Fiona J Gilbert
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | - Edmund Godfrey
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
| | - Martin J Graves
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | - Mary A McLean
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | - Evis Sala
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | | | - Joshua D Kaggie
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK.
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
| |
Collapse
|
21
|
McGivney DF, Boyacioğlu R, Jiang Y, Poorman ME, Seiberlich N, Gulani V, Keenan KE, Griswold MA, Ma D. Magnetic resonance fingerprinting review part 2: Technique and directions. J Magn Reson Imaging 2020; 51:993-1007. [PMID: 31347226 PMCID: PMC6980890 DOI: 10.1002/jmri.26877] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 07/05/2019] [Accepted: 07/05/2019] [Indexed: 12/12/2022] Open
Abstract
Magnetic resonance fingerprinting (MRF) is a general framework to quantify multiple MR-sensitive tissue properties with a single acquisition. There have been numerous advances in MRF in the years since its inception. In this work we highlight some of the recent technical developments in MRF, focusing on sequence optimization, modifications for reconstruction and pattern matching, new methods for partial volume analysis, and applications of machine and deep learning. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:993-1007.
Collapse
Affiliation(s)
- Debra F. McGivney
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Rasim Boyacioğlu
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Yun Jiang
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Megan E. Poorman
- Department of Physics, University of Colorado Boulder, Boulder, Colorado, USA
- Physical Measurement Laboratory, National Institute of Standards and Technology, Boulder, Colorado, USA
| | - Nicole Seiberlich
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Vikas Gulani
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Kathryn E. Keenan
- Physical Measurement Laboratory, National Institute of Standards and Technology, Boulder, Colorado, USA
| | - Mark A. Griswold
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Dan Ma
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
22
|
Nagtegaal M, Koken P, Amthor T, Doneva M. Fast multi-component analysis using a joint sparsity constraint for MR fingerprinting. Magn Reson Med 2020; 83:521-534. [PMID: 31418918 PMCID: PMC6899479 DOI: 10.1002/mrm.27947] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 07/22/2019] [Accepted: 07/23/2019] [Indexed: 12/18/2022]
Abstract
PURPOSE To develop an efficient algorithm for multi-component analysis of magnetic resonance fingerprinting (MRF) data without making a priori assumptions about the exact number of tissues or their relaxation properties. METHODS Different tissues or components within a voxel are potentially separable in MRF because of their distinct signal evolutions. The observed signal evolution in each voxel can be described as a linear combination of the signals for each component with a non-negative weight. An assumption that only a small number of components are present in the measured field of view is usually imposed in the interpretation of multi-component data. In this work, a joint sparsity constraint is introduced to utilize this additional prior knowledge in the multi-component analysis of MRF data. A new algorithm combining joint sparsity and non-negativity constraints is proposed and compared to state-of-the-art multi-component MRF approaches in simulations and brain MRF scans of 11 healthy volunteers. RESULTS Simulations and in vivo measurements show reduced noise in the estimated tissue fraction maps compared to previously proposed methods. Applying the proposed algorithm to the brain data resulted in 4 or 5 components, which could be attributed to different brain structures, consistent with previous multi-component MRF publications. CONCLUSIONS The proposed algorithm is faster than previously proposed methods for multi-component MRF and the simulations suggest improved accuracy and precision of the estimated weights. The results are easier to interpret compared to voxel-wise methods, which combined with the improved speed is an important step toward clinical evaluation of multi-component MRF.
Collapse
Affiliation(s)
- Martijn Nagtegaal
- Department of Quantitative ImagingTechnical University DelftDelftthe Netherlands
- Institut für MathematikTechnische Universität BerlinBerlinGermany
| | | | | | | |
Collapse
|