1
|
Shin IH, Kim KJ, Kim J, Kim HC, Chun H. Cation-selective electropreconcentration. LAB ON A CHIP 2014; 14:1811-5. [PMID: 24733115 DOI: 10.1039/c4lc00024b] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
A cation-selective microfluidic sample preconcentration system is described. The cation sample was electropreconcentrated using a reversed-direction electroosmotic flow (EOF) and an anion-permselective filter, where an electric double layer (EDL) overlap condition existed. The anion-permselective filter between microchannels was fabricated by three different methods: 1) extending a positively charged, nanoporous, polymer membrane by photopolymerization of poly(diallyldimethylammonium chloride) (PDADMAC); 2) etching a nanochannel and then coating it with a positively-charged monomer, N-[3-(trimethoxysilyl)propyl]-N'-(4-vinylbenzyl)ethylenediamine hydrochloride (TMSVE); and, 3) etching a nanochannel and then coating it with a positively-charged, pre-formed polymer, polyE-323. The EOF direction in the microchannel was reversed by both TMSVE and polyE-323 coatings. The cation-selective preconcentration was investigated using charged fluorescent dyes and tetramethylrhodamine isothiocyanate (TRITC)-tagged peptides/proteins. The preconcentration in the three different systems was compared with respect to efficiency, dependence on buffer concentration and pH, tolerable flow rate, and sample adsorption. Both TMSVE- and polyE-323-coated nanochannels showed robust preconcentration at high flow rates, whereas the PDADMAC membrane maintained anion-permselectivity at higher buffer concentrations. The TMSVE-coated nanochannels showed a more stable preconcentration process, whereas the polyE-323-coated nanochannels showed a lower peptide sample adsorption and robust efficiency under a wide range of buffer pHs. The system described here can potentially be used for the preconcentration of cationic peptides/proteins on microfluidic devices for subsequent analyses.
Collapse
Affiliation(s)
- Il Hyung Shin
- Department of Biomedical Engineering, Seoul National University, 28 Yongon-dong, Chongno-gu, Seoul, South Korea.
| | | | | | | | | |
Collapse
|
2
|
Abstract
Laser desorption/ionization mass spectrometry (MS) is rapidly growing in popularity as an analytical characterization method in several fields. The technique shot to prominence using matrix-assisted desorption/ionization for large biomolecules (>700 Da), such as proteins, peptides and nucleic acids. However, because the matrix, which consists of small organic molecules, is also ionized, the technique is of limited use in the low-molecular-mass range (<700 Da). Recent advances in surface science have facilitated the development of matrix-free laser desorption/ionization MS approaches, which are referred to here as surface-assisted laser desorption/ionization (SALDI) MS. In contrast to traditional matrix-assisted techniques, the materials used for SALDI-MS are not ionized, which expands the usefulness of this technique to small-molecule analyses. This review discusses the current status of SALDI-MS as a standard analytical technique, with an emphasis on potential applications in proteomics.
Collapse
Affiliation(s)
- Andrew M Dattelbaum
- Materials Science & Technology Division, Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
| | | |
Collapse
|
3
|
Tomalová I, Foltynová P, Kanický V, Preisler J. MALDI MS and ICP MS Detection of a Single CE Separation Record: A Tool for Metalloproteomics. Anal Chem 2013; 86:647-54. [DOI: 10.1021/ac402941e] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Iva Tomalová
- Central
European Institute of Technology (CEITEC), Masaryk University, Brno, Czech Republic
- Department
of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Pavla Foltynová
- Department
of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Viktor Kanický
- Central
European Institute of Technology (CEITEC), Masaryk University, Brno, Czech Republic
- Department
of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Jan Preisler
- Central
European Institute of Technology (CEITEC), Masaryk University, Brno, Czech Republic
- Department
of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| |
Collapse
|
4
|
Gasilova N, Gassner AL, Girault HH. Analysis of major milk whey proteins by immunoaffinity capillary electrophoresis coupled with MALDI-MS. Electrophoresis 2012; 33:2390-8. [DOI: 10.1002/elps.201200079] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Natalia Gasilova
- Laboratoire d'Electrochimie Physique et Analytique, Ecole Polytechnique Fédérale de Lausanne; Lausanne; Switzerland
| | - Anne-Laure Gassner
- Laboratoire d'Electrochimie Physique et Analytique, Ecole Polytechnique Fédérale de Lausanne; Lausanne; Switzerland
| | - Hubert H. Girault
- Laboratoire d'Electrochimie Physique et Analytique, Ecole Polytechnique Fédérale de Lausanne; Lausanne; Switzerland
| |
Collapse
|
5
|
Taube AB, Hardenborg E, Wetterhall M, Artemenko K, Hanrieder J, Andersson M, Alm A, Bergquist J. Proteins in aqueous humor from cataract patients with and without pseudoexfoliation syndrome. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2012; 18:531-541. [PMID: 23654198 DOI: 10.1255/ejms.1208] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The aim of this study was to investigate the protein content in aqueous humor in eyes with and without pseudoexfoliations (PEX) and to evaluate the quantitative proteomics method, isobaric tagging for relative and absolute protein quantification (iTRAQ), in combination with two separation methods followed by matrix-assisted Laser desorption/ionization (MALDI) mass spectrometry and tandem mass spectrometry (MS/MS). During cataract surgery, samples of aqueous humor were collected from 20 eyes with PEX and from 18 control eyes. The relative concentrations of proteins in the pooled samples of ten PEX eyes and eight controls were evaluated after trypsin digestion and Labeling of the peptides with (iTRAQ) reagent. Two separation methods, Liquid chromatography (LC) and capillary electrophoresis (CE) were used, followed by MALDI mass spectrometry and MS/MS. Furthermore, 1D gel electrophoresis was performed on the remaining ten pooled PEX samples and ten control samples. The gel material was separated by nano-liquid chromatography (nano-LC) followed by Linear-ion-trap quadrupole Fourier transformation ion cyclotron resonance (FT-ICR). Fifty four proteins were identified in the LC runs and 24 with CE. The relative concentrations of beta-crystallines B2 and S were raised and those of angiotensinogen and osteopontin Lowered in the PEX sample compared to the control. The trends regarding beta-crystallines B2, angiotensinogen and osteopontin were confirmed by the 1D gel electrophoresis.
Collapse
Affiliation(s)
- Amelie Botling Taube
- Department of Neuroscience, Uppsala Academic Hospital, Uppsala University, SE-751 85 UppsaLa, Sweden
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Hommerson P, Khan AM, de Jong GJ, Somsen GW. Ionization techniques in capillary electrophoresis-mass spectrometry: principles, design, and application. MASS SPECTROMETRY REVIEWS 2011; 30:1096-1120. [PMID: 21462232 DOI: 10.1002/mas.20313] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2009] [Accepted: 06/03/2010] [Indexed: 05/30/2023]
Abstract
A major step forward in the development and application of capillary electrophoresis (CE) was its coupling to ESI-MS, first reported in 1987. More than two decades later, ESI has remained the principal ionization technique in CE-MS, but a number of other ionization techniques have also been implemented. In this review the state-of-the-art in the employment of soft ionization techniques for CE-MS is presented. First the fundamentals and general challenges of hyphenating conventional CE and microchip electrophoresis with MS are outlined. After elaborating on the characteristics and role of ESI, emphasis is put on alternative ionization techniques including sonic spray ionization (SSI), thermospray ionization (TSI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), matrix-assisted laser desorption ionization (MALDI) and continuous-flow fast atom bombardment (CF-FAB). The principle of each ionization technique is outlined and the experimental set-ups of the CE-MS couplings are described. The strengths and limitations of each ionization technique with respect to CE-MS are discussed and the applicability of the various systems is illustrated by a number of typical examples.
Collapse
MESH Headings
- Electrophoresis, Capillary/instrumentation
- Electrophoresis, Capillary/methods
- Equipment Design/instrumentation
- Equipment Design/methods
- Pharmaceutical Preparations/analysis
- Pharmaceutical Preparations/chemistry
- Proteins/analysis
- Proteins/chemistry
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
Collapse
Affiliation(s)
- Paul Hommerson
- Department of Biomedical Analysis, Utrecht University, PO Box 80082, 3508 TB Utrecht, The Netherlands.
| | | | | | | |
Collapse
|
7
|
On-chip solid phase extraction and enzyme digestion using cationic PolyE-323 coatings and porous polymer monoliths coupled to electrospray mass spectrometry. J Chromatogr A 2011; 1218:4039-44. [DOI: 10.1016/j.chroma.2011.04.027] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2011] [Revised: 04/10/2011] [Accepted: 04/11/2011] [Indexed: 11/19/2022]
|
8
|
Wang J, Ye H, Zhang Z, Xiang F, Girdaukas G, Li L. Advancing matrix-assisted laser desorption/ionization-mass spectrometric imaging for capillary electrophoresis analysis of peptides. Anal Chem 2011; 83:3462-9. [PMID: 21417482 DOI: 10.1021/ac200708f] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
In this work, the utilization of matrix-assisted laser desorption/ionization-mass spectrometric imaging (MALDI-MSI) for capillary electrophoresis (CE) analysis of peptides based on a simple and robust off-line interface has been investigated. The interface involves sliding the CE capillary distal end within a machined groove on a MALDI sample plate, which is precoated with a thin layer of matrix for continuous sample deposition. MALDI-MSI by time of flight (TOF)/TOF along the CE track enables high-resolution and high-sensitivity detection of peptides, allowing the reconstruction of a CE electropherogram while providing accurate mass measurements and structural identification of molecules. Neuropeptide standards and their H/D isotopic formaldehyde-labeled derivatives were analyzed using this new platform. Normalized intensity ratios of individual ions extracted from the CE trace were compared to MALDI-MS direct analysis and the theoretical ratios. The CE-MALDI-MSI results show potential for sensitive and quantitative analysis of peptide mixtures spanning a wide dynamic range.
Collapse
Affiliation(s)
- Junhua Wang
- School of Pharmacy, University of Wisconsin-Madison, 53705, United States
| | | | | | | | | | | |
Collapse
|
9
|
Peš O, Preisler J. Off-line coupling of microcolumn separations to desorption mass spectrometry. J Chromatogr A 2010; 1217:3966-77. [DOI: 10.1016/j.chroma.2010.02.058] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2009] [Revised: 02/22/2010] [Accepted: 02/24/2010] [Indexed: 01/13/2023]
|
10
|
Vannatta MW, Whitmore CD, Dovichi NJ. CE-MALDI interface based on inkjet technology. Electrophoresis 2010; 30:4071-4. [PMID: 19960472 DOI: 10.1002/elps.200900414] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
An ink jet printer valve and a nozzle were used to deliver matrix and sample from an electrophoresis capillary onto a MALDI plate. The system was evaluated by the separation of a set of standard peptides. That separation generated up to 40 000 theoretical plates in less than 3 min. Detection limits were 500 amol for an ABI TOF-TOF instrument and 2 fmol for an ABI Q-TOF instrument. Over 70% coverage was obtained for the tryptic digest of alpha-lactalbumin in less than 2.5 min.
Collapse
|
11
|
Kasicka V. From micro to macro: conversion of capillary electrophoretic separations of biomolecules and bioparticles to preparative free-flow electrophoresis scale. Electrophoresis 2009; 30 Suppl 1:S40-52. [PMID: 19517515 DOI: 10.1002/elps.200900156] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
This invited contribution in the special issue of Electrophoresis published in celebration of the 30th Anniversary of this journal reflects the impact of our milestone paper [Prusík, Z., Kasicka, V., Mudra, P., Stepánek, J., Smékal, O., Hlavácek, J., Electrophoresis 1990, 11, 932-936] in the area of conversion of microscale analytical and micropreparative CE separations of biomolecules and bioparticles into (macro)preparative free-flow electrophoresis (FFE) scale on the basis of a correlation between CE and FFE methods. In addition to the survey of advances in the relatively narrow field of CE-FFE correlation and CE-FFE conversion, a comprehensive review of the recent developments of micropreparative CE and (macro)preparative FFE techniques is also presented and applications of these techniques to micro- and (macro)preparative separations and purifications of biomolecules and bioparticles are demonstrated. The review covers the period since the year of publication of the above paper, i.e. ca. the last 20 years.
Collapse
Affiliation(s)
- Václav Kasicka
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Prague, Czech Republic.
| |
Collapse
|
12
|
Yamamoto T, Murakami Y, Motoyanagi J, Fukushima T, Maruyama S, Kato M. An Analytical System for Single Nanomaterials: Combination of Capillary Electrophoresis with Raman Spectroscopy or with Scanning Probe Microscopy for Individual Single-Walled Carbon Nanotube Analysis. Anal Chem 2009; 81:7336-41. [DOI: 10.1021/ac901197v] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Tatsuhiro Yamamoto
- Center for NanoBio Integration, The University of Tokyo, Tokyo 113-8656, Japan, Department of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan, ERATO−SORST Aida Nanospace Project, Japan Science and Technology Agency, National Museum of Emerging Science and Innovation, Tokyo 135-0064, Japan, Functional Soft Matter Engineering Laboratory, Advanced Science Institute, RIKEN, Saitama 351-0198, Japan, Department of Mechanical Engineering, Graduate
| | - Yoichi Murakami
- Center for NanoBio Integration, The University of Tokyo, Tokyo 113-8656, Japan, Department of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan, ERATO−SORST Aida Nanospace Project, Japan Science and Technology Agency, National Museum of Emerging Science and Innovation, Tokyo 135-0064, Japan, Functional Soft Matter Engineering Laboratory, Advanced Science Institute, RIKEN, Saitama 351-0198, Japan, Department of Mechanical Engineering, Graduate
| | - Jin Motoyanagi
- Center for NanoBio Integration, The University of Tokyo, Tokyo 113-8656, Japan, Department of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan, ERATO−SORST Aida Nanospace Project, Japan Science and Technology Agency, National Museum of Emerging Science and Innovation, Tokyo 135-0064, Japan, Functional Soft Matter Engineering Laboratory, Advanced Science Institute, RIKEN, Saitama 351-0198, Japan, Department of Mechanical Engineering, Graduate
| | - Takanori Fukushima
- Center for NanoBio Integration, The University of Tokyo, Tokyo 113-8656, Japan, Department of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan, ERATO−SORST Aida Nanospace Project, Japan Science and Technology Agency, National Museum of Emerging Science and Innovation, Tokyo 135-0064, Japan, Functional Soft Matter Engineering Laboratory, Advanced Science Institute, RIKEN, Saitama 351-0198, Japan, Department of Mechanical Engineering, Graduate
| | - Shigeo Maruyama
- Center for NanoBio Integration, The University of Tokyo, Tokyo 113-8656, Japan, Department of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan, ERATO−SORST Aida Nanospace Project, Japan Science and Technology Agency, National Museum of Emerging Science and Innovation, Tokyo 135-0064, Japan, Functional Soft Matter Engineering Laboratory, Advanced Science Institute, RIKEN, Saitama 351-0198, Japan, Department of Mechanical Engineering, Graduate
| | - Masaru Kato
- Center for NanoBio Integration, The University of Tokyo, Tokyo 113-8656, Japan, Department of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan, ERATO−SORST Aida Nanospace Project, Japan Science and Technology Agency, National Museum of Emerging Science and Innovation, Tokyo 135-0064, Japan, Functional Soft Matter Engineering Laboratory, Advanced Science Institute, RIKEN, Saitama 351-0198, Japan, Department of Mechanical Engineering, Graduate
| |
Collapse
|
13
|
Zuberovic A, Wetterhall M, Hanrieder J, Bergquist J. CE MALDI-TOF/TOF MS for multiplexed quantification of proteins in human ventricular cerebrospinal fluid. Electrophoresis 2009; 30:1836-43. [DOI: 10.1002/elps.200800714] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
14
|
Hanrieder J, Zuberovic A, Bergquist J. Surface modified capillary electrophoresis combined with in solution isoelectric focusing and MALDI-TOF/TOF MS: A gel-free multidimensional electrophoresis approach for proteomic profiling—Exemplified on human follicular fluid. J Chromatogr A 2009; 1216:3621-8. [DOI: 10.1016/j.chroma.2008.12.026] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2008] [Revised: 12/04/2008] [Accepted: 12/15/2008] [Indexed: 11/30/2022]
|
15
|
Wang J, Ma M, Chen R, Li L. Enhanced neuropeptide profiling via capillary electrophoresis off-line coupled with MALDI FTMS. Anal Chem 2008; 80:6168-77. [PMID: 18642879 DOI: 10.1021/ac800382t] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An off-line interface incorporating sheathless flow and counter-flow balance is developed to couple capillary electrophoresis (CE) to matrix-assisted laser desorption ionization Fourier transform mass spectrometry (MALDI FTMS) for neuropeptide analysis of complex tissue samples. The new interface provides excellent performance due to the integration of three aspects: (1) A porous polymer joint constructed near the capillary outlet for the electrical circuit completion has simplified the CE interface by eliminating a coaxial sheath liquid and enables independent optimization of separation and deposition. (2) The electroosmotic flow at reversed polarity (negative) mode CE is balanced and reversed by a pressure-initiated capillary siphoning (PICS) phenomenon, which offers improved CE resolution and simultaneously generates a low flow (<100 nL/min) for fraction collection. (3) The predeposited nanoliter volume 2,5-dihydroxybenzoic acid (DHB) spots on a Parafilm-coated MALDI sample plate offers an improved substrate for effective effluent enrichment. Compared with direct MALDI MS analysis, CE separation followed by MALDI MS detection consumes nearly 10-fold less sample (50 nL) while exhibiting 5-10-fold enhancement in S/N ratio that yields the limit of detection down to 1.5 nM, or 75 attomoles. This improvement in sensitivity allows 230 peaks detected in crude extracts from only a few pooled neuronal tissues and increases the number of identified peptides from 19 to 43 (Cancer borealis pericardial organs (n = 4)) in a single analysis. In addition, via the characteristic migration behaviors in CE, some specific structural and chemical information of the neuropeptides such as post-translational modifications and family variations has been visualized, making the off-line CE-MALDI MS a promising strategy for enhanced neuropeptidomic profiling.
Collapse
Affiliation(s)
- Junhua Wang
- School of Pharmacy and Department of Chemistry, University of Wisconsin-Madison, 777 Highland Avenue, Madison, Wisconsin 53705-2222, USA
| | | | | | | |
Collapse
|
16
|
Wu X, Wei W, Su Q, Xu L, Chen G. Simultaneous separation of basic and acidic proteins using 1-butyl-3-methylimidazolium-based ion liquid as dynamic coating and background electrolyte in capillary electrophoresis. Electrophoresis 2008; 29:2356-62. [DOI: 10.1002/elps.200700746] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
17
|
Ekegren T, Hanrieder J, Bergquist J. Clinical perspectives of high-resolution mass spectrometry-based proteomics in neuroscience: exemplified in amyotrophic lateral sclerosis biomarker discovery research. JOURNAL OF MASS SPECTROMETRY : JMS 2008; 43:559-571. [PMID: 18416436 DOI: 10.1002/jms.1409] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Biomarker discovery is a central application in today's proteomic research. There is an urgent need for valid biomarkers to improve diagnostic tools and treatment in many disorders, such as the rapidly progressing neurodegenerative disorder amyotrophic lateral sclerosis (ALS) that has a fatal outcome in about 3 years and yet no curative treatment. Screening for clinically relevant biomarkers puts high demands on high-throughput, rapid and precise proteomic techniques. There is a large variety in the methods of choice involving mainly gel-based approaches as well as chromatographic techniques for multi-dimensional protein and peptide separations followed by mass spectrometry (MS) analysis. This special feature article will discuss some important aspects of MS-based clinical proteomics and biomarker discovery in the field of neurodegenerative diseases and ALS research respectively, with the aim to provide a prospective view on current and future research aspects in the field. Furthermore, examples for application of high-resolution MS-based proteomic strategies for ALS biomarker discovery will be demonstrated with two studies previously reported by our group. These studies include among others, utilization of capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry (LC-FTICR-MS) for advanced protein pattern classification in cerebrospinal fluid (CSF) samples of ALS patients as well as highly sensitive protein identification in minimal amounts of postmortem spinal cord tissue and laser micro-dissected motor neurons using FT-ICR-MS in conjunction with nanoflow LC coupled to matrix-assisted laser desorption ionization time-of-flight tandem mass spectrometry (LC-MALDI-TOF-TOF-MS).
Collapse
Affiliation(s)
- Titti Ekegren
- Department of Physical and Analytical Chemistry, Uppsala University, Uppsala, Sweden
| | | | | |
Collapse
|
18
|
Capillary electrophoresis analysis of biofluids with a focus on less commonly analyzed matrices. J Chromatogr B Analyt Technol Biomed Life Sci 2008; 866:154-66. [DOI: 10.1016/j.jchromb.2008.01.058] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2007] [Revised: 01/23/2008] [Accepted: 01/24/2008] [Indexed: 12/19/2022]
|
19
|
Lucy CA, MacDonald AM, Gulcev MD. Non-covalent capillary coatings for protein separations in capillary electrophoresis. J Chromatogr A 2008; 1184:81-105. [DOI: 10.1016/j.chroma.2007.10.114] [Citation(s) in RCA: 252] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2007] [Revised: 10/25/2007] [Accepted: 10/31/2007] [Indexed: 11/27/2022]
|
20
|
Zuberovic A, Hanrieder J, Hellman U, Bergquist J, Wetterhall M. Proteome profiling of human cerebrospinal fluid: exploring the potential of capillary electrophoresis with surface modified capillaries for analysis of complex biological samples. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2008; 14:249-260. [PMID: 18756023 DOI: 10.1255/ejms.929] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A bottom-up proteomic approach, based on capillary electrophoresis (CE) in combination with matrix- assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-ToF/ToF MS), was used to analyze immunoaffinity depleted human cerebrospinal fluid (CSF) and compare it with a non-depleted sample. After enzymatic digestion and desalting, the tryptic peptides were separated by CE using PolyE-323 modified capillaries and fractionated off-line onto MALDI target plates for further analysis by MALDI-MS and MS/MS. The protein profile of the depleted sample was compared with non depleted CSF. Overall, 85 proteins were identified with 95% significance in both samples. The significance scores for proposed biomarkers, such as amyloid-like protein 1 precursor, could be increased up to 12 times after the depletion. Other proteins, often suggested to be related to neurodegenerative diseases, like amyloid beta A4 protein precursor, superoxide dismutase and apolipoprotein E precursor could only be found in the depleted CSF samples. The effect of a derivatization of tryptic peptides with 2- methoxy-4,5-dihydro-1H-imidazole reagent for protein identification with MS was also employed to increase the number of identified proteins and the sequence coverages. The results presented in this study illustrate the benefit of combining a sample pre-fractionation step and a label's ability to enhance the ionization efficiency with the potential of CE using PolyE-323 modified capillaries in the analysis of complex samples. The straight-forward approach that provides speed and simplicity resulting in high-resolution separations and low sample consumption represents an easily applicable separation technique that can serve as a complement to other currently existing analytical approaches needed in modern proteomic analysis of clinically relevant samples.
Collapse
Affiliation(s)
- Aida Zuberovic
- Department of Physical and Analytical Chemistry, Analytical Chemistry, Uppsala University, PO Box 599, SE-751 24 Uppsala, Sweden
| | | | | | | | | |
Collapse
|
21
|
Ullsten S, Zuberovic A, Bergquist J. Adsorbed cationic polymer coatings for enhanced capillary electrophoresis/mass spectrometry of proteins. Methods Mol Biol 2008; 384:631-646. [PMID: 18392587 DOI: 10.1007/978-1-59745-376-9_25] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The combination of capillary electrophoresis (CE) with mass spectrometry (MS) constitutes a powerful microanalytical system for the analysis of biological samples. The anionic and hydrophobic surface of the fused-silica capillary is, however, known to cause severe analyte-wall interactions in protein analysis. In order to control surface properties and eliminate protein adsorption, a capillary coating can be applied. A fast and simple strategy is to coat the anionic capillary with a cationic polymer via multisite electrostatic interaction. This generates a stable deactivation layer, without the need for addition of coating agent to the background electrolyte solution. This chapter reviews the present knowledge of capillary coatings and especially cationic polymers in CE-MS, and describes the synthesis of a cationic polymer, PolyE-323, for deactivation of fused-silica capillaries. The capillary coating procedure is a simple three-step rinsing protocol comprising deprotonation of surface silanol groups using a base, adsorption of polymer, and a final rinse to remove excess polymer not adsorbed to the surface. As a result of the simplicity of the coating procedure, highly reproducible coatings can be prepared with little or no expert skills. Some practical aspects on using cationic-coated capillaries in CE-MS protein analysis are also discussed.
Collapse
Affiliation(s)
- Sara Ullsten
- Department of Analytical Chemistry, Biomedical Centre, Uppsala University, Uppsala, Sweden
| | | | | |
Collapse
|
22
|
Haselberg R, de Jong GJ, Somsen GW. Capillary electrophoresis–mass spectrometry for the analysis of intact proteins. J Chromatogr A 2007; 1159:81-109. [PMID: 17560583 DOI: 10.1016/j.chroma.2007.05.048] [Citation(s) in RCA: 120] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2007] [Revised: 05/01/2007] [Accepted: 05/15/2007] [Indexed: 10/23/2022]
Abstract
Developments in the fields of protein chemistry, proteomics and biotechnology have increased the demand for suitable analytical techniques for the analysis of intact proteins. In 1989, capillary electrophoresis (CE) was combined with mass spectrometry (MS) for the first time and its potential usefulness for the analysis of intact (i.e. non-digested) proteins was shown. This article provides an overview of the applications of CE-MS within the field of intact protein analysis. The principles of the applied CE modes and ionization techniques used for CE-MS of intact proteins are shortly described. It is shown that separations are predominantly carried out by capillary zone electrophoresis and capillary isoelectric focusing, whereas electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are the most popular ionization techniques used for interfacing. The combination of CE with inductively coupled plasma (ICP) MS for the analysis of metalloproteins is also discussed. The various CE-MS combinations are systematically outlined and tables provide extensive overviews of the applications of each technique for intact protein analysis. Selected examples are given to illustrate the usefulness of the CE-MS techniques. Examples include protein isoform assignment, single cell analysis, metalloprotein characterization, proteomics and biomarker screening. Finally, chip-based electrophoresis combined with MS is shortly treated and some of its applications are described. It is concluded that CE-MS represents a powerful tool for the analysis of intact proteins yielding unique separations and information.
Collapse
Affiliation(s)
- Rob Haselberg
- Department of Biomedical Analysis, Utrecht University, 3508 TB Utrecht, The Netherlands.
| | | | | |
Collapse
|
23
|
Thongboonkerd V. Recent progress in urinary proteomics. Proteomics Clin Appl 2007; 1:780-91. [PMID: 21136734 DOI: 10.1002/prca.200700035] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2007] [Indexed: 11/08/2022]
Abstract
Urinary proteomics has become one of the most attractive subdisciplines in clinical proteomics as the urine is an ideal source for the discovery of noninvasive biomarkers for kidney and nonkidney diseases. This field has been growing rapidly as indicated by >80 original research articles on urinary proteome analyses appearing since 2001, of which 28 (approximately 1/3) had been published within the year 2006. The most common technologies used in recent urinary proteome studies remain gel-based methods (1-DE, 2-DE and 2-D DIGE), whereas LC-MS/MS, SELDI-TOF MS, and CE-MS are other commonly used techniques. In addition, mass spectrometric immunoassay (MSIA) and array technology have also been applied. This review provides an extensive but concise summary of recent applications of urinary proteomics. Proteomic analyses of dialysate and ultrafiltrate fluids derived from renal replacement therapy (or artificial kidney) are also discussed.
Collapse
Affiliation(s)
- Visith Thongboonkerd
- Medical Molecular Biology Unit, Office for Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. ,
| |
Collapse
|
24
|
Solínová V, Kasicka V, Sázelová P, Barth T, Miksík I. Separation and investigation of structure–mobility relationship of gonadotropin-releasing hormones by capillary zone electrophoresis in conventional and isoelectric acidic background electrolytes. J Chromatogr A 2007; 1155:146-53. [PMID: 17229433 DOI: 10.1016/j.chroma.2007.01.019] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2006] [Revised: 12/22/2006] [Accepted: 01/05/2007] [Indexed: 11/25/2022]
Abstract
Capillary zone electrophoresis (CZE) has been applied to qualitative and quantitative analysis, separation and physicochemical characterization of synthetic gonadotropin-releasing hormones (GnRHs) and their analogs and fragments. Structurally related peptides were separated in conventional and isoelectric acidic background electrolytes (BGEs), pH 2.18-2.50. Best separation was achieved in isoelectric BGE composed of 200 mM iminodiacetic acid, pH 2.32. The effective electrophoretic mobilities, m(ep), of GnRHs in five BGEs were determined and four semiempirical models correlating effective mobility with charge, q, and relative molecular mass, M(r), (m(ep) versus q/M(r)(k), where k is related to the molecular shape) were tested to describe the migration behavior of GnRHs in CZE. None of the models was found to be quite definitively applicable for the whole set of 10 GnRHs differing in size (tetrapeptide-decapeptide) and positive charge (0.91-3.00 elementary charges). Nevertheless, for the dependence of m(ep) on q/M(r)(k), the highest coefficient of correlation, R=0.995-0.999, was obtained for k close to the value 0.5 in all five acidic BGEs. This indicates that the most probable structure of GnRHs in these BGEs can be predicted as a random coil.
Collapse
Affiliation(s)
- Veronika Solínová
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Flemingovo 2, 166 10 Prague 6, Czech Republic
| | | | | | | | | |
Collapse
|
25
|
Kovarik P, Hodgson RJ, Covey T, Brook MA, Brennan JD. Capillary-scale frontal affinity chromatography/MALDI tandem mass spectrometry using protein-doped monolithic silica columns. Anal Chem 2007; 77:3340-50. [PMID: 15889927 DOI: 10.1021/ac048263p] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Frontal affinity chromatography (FAC) interfaced with electrospray mass spectrometry (ESI-MS) has been reported as a potential method for screening of compound mixtures against immobilized target proteins. However, the interfacing of bioaffinity columns to ESI-MS requires that the eluent that passes through the protein-loaded column have a relatively low ionic strength to produce a stable spray. Such low ionic strength solvents can cause serious problems with protein stability and may also affect binding constants and lead to high nonspecific binding to the column. Herein, we report on the interfacing of bioaffinity columns to matrix-assisted laser desorption/ionization (MALDI) MS/MS as a new platform for FAC/MS studies. Capillary columns containing a monolithic silica material with entrapped dihydrofolate reductase were used for frontal affinity chromatography of small-molecule mixtures. The output from the column was combined with a second stream containing alpha-cyano-hydoxycinnamic acid in methanol and was deposited using a nebulizer-assisted electrospray method onto a conventional MALDI plate that moved relative to the column via a computer-controlled x-y stage, creating a semipermanent record of the FAC run. The use of MALDI MS/MS allowed for buffers with significantly higher ionic strength to be used for FAC studies, which reduced nonspecific binding of ionic compounds and allowed for better retention of protein activity over multiple runs. Following deposition, MALDI analysis required only a fraction of the chromatographic run time, and the deposited track could be rerun multiple times to optimize ionization parameters and allow signal averaging to improve the signal-to-noise ratio. Furthermore, high levels of potential inhibitors could be detected via MALDI with limited ion suppression effects. Both MALDI- and ESI-based analysis showed similar retention of inhibitors present in compound mixtures when using identical ionic strength conditions. The results show that FAC/MALDI-MS should provide advantages over FAC/ESI-MS for high-throughput screening of compound mixtures.
Collapse
Affiliation(s)
- Peter Kovarik
- MDS/Sciex, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
| | | | | | | | | |
Collapse
|
26
|
Catai JR, Toraño JS, de Jong GJ, Somsen GW. Capillary electrophoresis–mass spectrometry of proteins at medium pH using bilayer-coated capillaries. Analyst 2007; 132:75-81. [PMID: 17180183 DOI: 10.1039/b607178c] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The feasibility of using noncovalently bilayer-coated capillaries for capillary electrophoresis-mass spectrometry (CE-MS) of acidic proteins was investigated using background electrolytes (BGEs) of medium pH. The capillary was coated by successively rinsing the capillary with solutions of the oppositely charged polymers polybrene (PB) and poly(vinyl sulfonic acid) (PVS). Volatile BGEs containing ammonium formate and/or N-methyl morpholine were tested at pH 7.5 and 8.5. Overall, these BGEs provided relatively fast protein separations (analysis times of ca. 12 min) and showed high efficiencies (70,000-300,000 plates) when the ionic strength was sufficiently high. Migration-time reproducibilities were very favorable with RSDs of less than 1.0%. Infusion experiments showed satisfactory MS responses for studied proteins dissolved in ammonium formate (pH 8.5), however, high concentrations of N-methyl morpholine appeared to seriously suppress the MS protein signals. Evaluation of the CE-MS system was performed by analyzing a mixture of intact proteins yielding efficient separations and good-quality mass spectra. CE-MS analysis of a reconstituted formulation of the biopharmaceutical recombinant human growth hormone (rhGH) which was stored for a prolonged time, revealed one degradation product which was provisionally identified as desamido rhGH. Based on the MS responses the amount of degradation was estimated to be ca. 25%.
Collapse
Affiliation(s)
- Jonatan R Catai
- Department of Biomedical Analysis, Utrecht University, P.O. Box 80082, 3508 TB Utrecht, The Netherlands
| | | | | | | |
Collapse
|
27
|
Nordhoff E, Lehrach H. Identification and characterization of DNA-binding proteins by mass spectrometry. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2006; 104:111-95. [PMID: 17290821 DOI: 10.1007/10_2006_037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Mass spectrometry is the most sensitive and specific analytical technique available for protein identification and quantification. Over the past 10 years, by the use of mass spectrometric techniques hundreds of previously unknown proteins have been identified as DNA-binding proteins that are involved in the regulation of gene expression, replication, or DNA repair. Beyond this task, the applications of mass spectrometry cover all aspects from sequence and modification analysis to protein structure, dynamics, and interactions. In particular, two new, complementary ionization techniques have made this possible: matrix-assisted laser desorption/ionization and electrospray ionization. Their combination with different mass-over-charge analyzers and ion fragmentation techniques, as well as specific enzymatic or chemical reactions and other analytical techniques, has led to the development of a broad repertoire of mass spectrometric methods that are now available for the identification and detailed characterization of DNA-binding proteins. These techniques, how they work, what their requirements and limitations are, and selected examples that document their performance are described and discussed in this chapter.
Collapse
Affiliation(s)
- Eckhard Nordhoff
- Department Lehrach, Max Planck Institute for Molecular Genetics, Ihnestrasse 73, 14195 Berlin, Germany.
| | | |
Collapse
|
28
|
Huck CW, Bakry R, Huber LA, Bonn GK. Progress in capillary electrophoresis coupled to matrix-assisted laser desorption/ionization - time of flight mass spectrometry. Electrophoresis 2006; 27:2063-74. [PMID: 16645982 DOI: 10.1002/elps.200600046] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In this review the most important techniques developed to hyphenate CE to MALDI-TOF-MS are summarized. The principles of the different interfaces and ways to solve the hyphenation problem are explained and discussed in detail. The most important applications especially in the proteomic field are reviewed, and the advantages of CE-MALDI-TOF-MS for the analysis of these compounds compared to other techniques such as ESI-MS are exhaustingly discussed from a critical point of view. CE coupled to MALDI-TOF-MS has started to overpass traditionally used CE-coupling techniques, especially CE-ESI-MS, offering the possibility to analyze samples of interest even weeks after CE analysis and using multiplexing systems for high-sample throughput.
Collapse
Affiliation(s)
- Christian W Huck
- Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens University, Innsbruck, Austria.
| | | | | | | |
Collapse
|
29
|
Huang YF, Huang CC, Hu CC, Chang HT. Capillary electrophoresis-based separation techniques for the analysis of proteins. Electrophoresis 2006; 27:3503-22. [PMID: 16927348 DOI: 10.1002/elps.200600100] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
CE offers the advantages of high speed, great efficiency, as well as the requirement of minimum amounts of sample and buffer for the analysis of proteins. In this review, we summarize the CE-based techniques coupled with absorption, LIF, and MS detection systems for the analysis of proteins mostly within the past 5 years. The basic principle of each technique and its advantages and disadvantages for protein analysis are discussed in brief. Advanced CE techniques, including on-column concentration techniques and high-efficiency multidimensional separation techniques, for high-throughput protein profiling of complex biological samples and/or of single cells are emphasized. Although the developed techniques provide improved peak capacity, they have not become practical tools for proteomics, mainly because of poor reproducibility, low-sample lading capacity, and low throughput due to ineffective interfaces between two separation dimensions and that between separation and MS systems. In order to identify the complexities and dynamics of the proteomes expressed by cells, tissues, or organisms, techniques providing improved analytical sensitivity, throughput, and dynamic ranges are still demanded.
Collapse
Affiliation(s)
- Yu-Fen Huang
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | | | |
Collapse
|
30
|
Abstract
Diabetes is a common disease worldwide and can cause several complications, leading to systemic derangements and end-organ damage. Despite blood sugar control and adequate therapy with currently available drugs, diabetic complications remain a serious issue in clinical practice, indicating that our knowledge of diabetes and its complications is only at the tip of the iceberg. Better understanding of its pathogenesis and pathophysiology is crucial to achieve better therapeutic outcomes and to prevent its complications. This review provides an overview of proteomics and introduces proteomic technologies commonly used for diabetes research. Recent proteomic studies for the investigation of diabetes and its complications are summarized. Finally, the future perspectives for the field of proteomics in diabetes research are discussed.
Collapse
Affiliation(s)
- Visith Thongboonkerd
- a Medical Molecular Biology Unit, Office for Research and Development, Faculty of Medicine at Siriraj Hospital, Mahidol University, 12th Floor, Adulyadej Vikrom Building, Siriraj Hospital, 2 Prannok Road, Bangkoknoi, Bangkok, 10700, Thailand.
| |
Collapse
|
31
|
Zürbig P, Renfrow MB, Schiffer E, Novak J, Walden M, Wittke S, Just I, Pelzing M, Neusüss C, Theodorescu D, Root KE, Ross MM, Mischak H. Biomarker discovery by CE-MS enables sequence analysisvia MS/MS with platform-independent separation. Electrophoresis 2006; 27:2111-25. [PMID: 16645980 DOI: 10.1002/elps.200500827] [Citation(s) in RCA: 158] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
CE-MS is a successful proteomic platform for the definition of biomarkers in different body fluids. Besides the biomarker defining experimental parameters, CE migration time and molecular weight, especially biomarker's sequence identity is an indispensable cornerstone for deeper insights into the pathophysiological pathways of diseases or for made-to-measure therapeutic drug design. Therefore, this report presents a detailed discussion of different peptide sequencing platforms consisting of high performance separation method either coupled on-line or off-line to different MS/MS devices, such as MALDI-TOF-TOF, ESI-IT, ESI-QTOF and Fourier transform ion cyclotron resonance, for sequencing indicative peptides. This comparison demonstrates the unique feature of CE-MS technology to serve as a reliable basis for the assignment of peptide sequence data obtained using different separation MS/MS methods to the biomarker defining parameters, CE migration time and molecular weight. Discovery of potential biomarkers by CE-MS enables sequence analysis via MS/MS with platform-independent sample separation. This is due to the fact that the number of basic and neutral polar amino acids of biomarkers sequences distinctly correlates with their CE-MS migration time/molecular weight coordinates. This uniqueness facilitates the independent entry of different sequencing platforms for peptide sequencing of CE-MS-defined biomarkers from highly complex mixtures.
Collapse
Affiliation(s)
- Petra Zürbig
- Mosaiques Diagnostics & Therapeutics AG, Hannover, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Lindberg P, Dahlin AP, Bergström SK, Thorslund S, Andrén PE, Nikolajeff F, Bergquist J. Sample pretreatment on a microchip with an integrated electrospray emitter. Electrophoresis 2006; 27:2075-82. [PMID: 16645978 DOI: 10.1002/elps.200500763] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This study presents a microbead-packed PDMS microchip with an integrated electrospray emitter for sample pretreatment prior to sheathless ESI-MS. We prove the concept of analytical functions integrated onto a cm-sized area of a single bulk material. The microchip consists of two PDMS substrates replicated from SU-8 fabricated silicon wafer masters, bonded together after oxidation by corona discharge treatment. The channel within the microchip contains a grid structure that was used to trap 5 microm hypercross-linked polystyrene beads. The beads acted as a medium for sample desalting and enrichment. Electrical contact for the sheathless ESI process was achieved by coating the integrated emitter with conductive graphite powder after applying a thin layer of PDMS as glue. The coating as well as the bond of the PDMS structures showed excellent durability. A continuous spray was obtained from the microchip for over 800 h in a long-term electrospray stability experiment. Desalting and enrichment of neuropeptides from a physiological salt solution was successful by loading the sample onto the packed beads, followed by a washing and an eluting step. The results were obtained and evaluated using a TOF MS. An LOD of approximately 20 fmol (loaded onto the beads) for angiotensin II was obtained from a sample of neuropeptides dissolved in physiological salt solution.
Collapse
Affiliation(s)
- Peter Lindberg
- Department of Analytical Chemistry, Uppsala University, Sweden
| | | | | | | | | | | | | |
Collapse
|
33
|
Kraly J, Fazal MA, Schoenherr RM, Bonn R, Harwood MM, Turner E, Jones M, Dovichi NJ. Bioanalytical Applications of Capillary Electrophoresis. Anal Chem 2006; 78:4097-110. [PMID: 16771542 DOI: 10.1021/ac060704c] [Citation(s) in RCA: 105] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- James Kraly
- Department of Chemistry, University of Washington, Seattle, Washington 98195-1700, USA
| | | | | | | | | | | | | | | |
Collapse
|
34
|
Kasicka V. Recent developments in capillary electrophoresis and capillary electrochromatography of peptides. Electrophoresis 2006; 27:142-75. [PMID: 16307429 DOI: 10.1002/elps.200500527] [Citation(s) in RCA: 133] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The article gives a comprehensive review on the recent developments in the applications of high-performance capillary electromigration methods, zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography, and electrochromatography, to analysis, preparation, and physicochemical characterization of peptides. The article presents new approaches to the theoretical description and experimental verification of electromigration behavior of peptides, covers the methodological aspects of capillary electroseparations of peptides, such as rational selection of separation conditions, sample preparation, suppression of peptide adsorption, new developments in individual separation modes, and new designs of detection systems. Several types of applications of capillary electromigration methods to peptide analysis are presented: conventional qualitative and quantitative analysis, purity control, determination in biomatrices, monitoring of chemical and enzymatical reactions and physical changes, amino acid and sequence analysis, and peptide mapping of proteins. Some examples of micropreparative peptide separations are given and capabilities of capillary electromigration techniques to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- Václav Kasicka
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Prague, Czech Republic.
| |
Collapse
|
35
|
Abstract
This review article with 304 references describes recent developments in CE of proteins, and covers the two years since the previous review (Hutterer, K., Dolník, V., Electrophoresis 2003, 24, 3998-4012) through Spring 2005. It covers topics related to CE of proteins, including modeling of the electrophoretic migration of proteins, sample pretreatment, wall coatings, improving separation, various forms of detection, special electrophoretic techniques such as affinity CE, CIEF, and applications of CE to the analysis of proteins in real-world samples including human body fluids, food and agricultural samples, protein pharmaceuticals, and recombinant protein preparations.
Collapse
|
36
|
Fliser D, Wittke S, Mischak H. Capillary electrophoresis coupled to mass spectrometry for clinical diagnostic purposes. Electrophoresis 2005; 26:2708-16. [PMID: 15966014 DOI: 10.1002/elps.200500187] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The introduction of fast, sensitive, and robust techniques for proteomic analysis into clinical practice represents a major step toward a new diagnostic approach of body fluids. In addition, proteomics emerges as a key technology for the discovery of disease biomarkers in various body fluids. However, even in relatively protein-deprived body fluids such as urine, the complexity and wide dynamic range of protein expression pose a considerable challenge to both separation and identification technologies. In the present review we discuss from a clinical point-of-view recent advances of the use of proteomics in clinical diagnosis as well as therapy evaluation. We focus on capillary electrophoresis coupled to mass spectrometry (CE-MS) and discuss CE-MS from an application point of view evaluating its merits and vices with regard to biomarker discovery. This review further presents examples of clinical applications of CE-MS for detection and identification of biomarkers in urine.
Collapse
|
37
|
Chapter 10 Technologies interfacing capillary electrophoresis to mass spectrometry. ACTA ACUST UNITED AC 2005. [DOI: 10.1016/s0166-526x(05)46010-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|